KX Series Power Systems Catalog
Transcription
KX Series Power Systems Catalog
KX Series Power Systems Catalog 715 kVA - 3300 kVA, 50 HZ 700 kW - 3200 kW, 60 HZ 1 Total System Integration. Everything Works Together. Reliability of power systems is critical. Your business depends on it. At Kohler, we build industrial power systems that are proven to work because total system integration is engineered in from the start. For more than 90 years, Kohler has earned a global reputation as a pure power expert — in large part to our strict quality standards. Our power systems are equipped with Kohler innovation, including generators, transfer switches, switchgear and controllers. Enduring the industry’s toughest testing process, including transient power testing, cooling sound and more, every part is built to work with the entire system and perform in the most demanding environments before they are shipped out. Our power systems are built for nearly every application, powering everything from gas stations to hotels and hospitals, as well as military operations and airports. So you can be rest assured that our products will work when you need them most. Dependable Power and Performance Tried, Tested and Proven to Work. The new KX-series generators offer total, reliable and continuous power with a higher load factor^ as well as competitive fuel consumption rates. Incorporating Kohler’s innovative technology, the KX range enables a seamless integration that allows versatile system configurations for optimal performance. Today, Kohler provides integrated solutions to streamline the specifying process. Our industrial generators are diesel-fueled models — ranging from 5.5 kVA to 3,300 kVA @ 50 Hz (11 kW to 3200 kW @ 60 Hz) complete with electronic controls and automatic transfer switches. To help cater to unique installation environments, we also offer a range of accessories, including controls, silencers, enclosures, fuel tanks and block heaters. ^ 85% for standby rating; 75% for prime rating (70% for ISO standard). Disclaimer: Information in this publication represents product data available at the time of print. Kohler Co. reserves the right to change this publication and the products represented without notice and without any obligation or liability. 2 Kohler Headquarters/Manufacturing – U.S. Kohler Manufacturing – Singapore Kohler Manufacturing – China Kohler Manufacturing – France Kohler Manufacturing – India Kohler Service and Support The Help You Need. Any Time, Anywhere. Anybody can claim to offer an unrivaled level of support, but it is another thing to deliver on that promise. Today, Kohler’s distribution network spans across multiple sales offices in countries throughout the Asia Pacific region. Unlike other generator manufacturers, Kohler certified distributors and dealers specialize in power. This means our service network can be called on for anything related to your generator and its components. With Kohler, you enjoy world-class service and support from a global service network. 3 Emissions OPTIMIzATION 50-60 Hz KX880C KX1850C TECHNICAL SPECIFICATIONS 50 Hz Specifications 400-230 V Generator Set Model (1) kVA Cos 0.8 60 Hz Specifications 480-277 V Cons 3/4 L/h PRP ESP (3) (4) KX715C 650 715 109 KX800C 727 800 KX880C 800 880 KX1000 C 910 KX1100C KX1250C Generator Set Model (2) kWe ISO 8528* General Specifications Cons 3/4 L/h Alternator Engine Compact Version(5) Engine type cyl Bore (mm) Stroke (mm) Cyl (L) Type Dimensions LxWxH, m Weight(6) (kg) - 12V2000G25 12V 130 150 23.9 491S4 3.97x1.63x1.94 4989 700 131 12V2000G65R/45 12V 130 150 23.9 491M6 3.97x1.85x2.1 5262 800 148 12V2000G65/85 12V 130 150 23.9 491L9A 3.97x1.63x1.96 5474 818 900 168 16V2000G25/45 16V 130 150 31.8 491L10 4.37x1.84x2.19 6118 KX1000UC2 909 1000 184 16V2000G65/85 16V 130 150 31.8 491L11 4.37x1.84x2.19 6588 KX1200UC2 1091 1200 217 18V2000G65/85 18V 130 150 35.8 502M6 4.45x2.21x2.19 7383 PRP ESP (3) (4) - - - 113 KX700UC2 636 131 KX800UC2 727 1001 154 KX900UC2 1000 1100 169 1136 1250 192 KX1400C 1272 1400 209 - - - - 12V4000G21 12V 165 190 48.75 502L7 3.6x1.88x2.16 9778 KX1540C 1400 1540 226 - - - - 12V4000G23R1 12V 170 210 57.2 502L8 4.00x1.88x2.16 10640 KX1650C 1500 1650 251 - - - - 12V4000G23R2 12V 170 210 57.2 502VL10 4.16x1.88x2.16 10820 KX1850C 1663 1830 266 KX1600UC2 1400 1600 282 12V4000G23/43 12V 170 210 57.2 512S55 4.10x1.87x2.16 11405 KX2000C 1818 2000 298 KX1750UC2 1591 1750 319 12V4000G63/83 12V 170 210 57.2 512S55 4.10x1.87x2.16 11405 KX2200C 2000 2200 336 KX2000UC2 1818 2000 377 16V4000G23/43 16V 170 210 76.3 512M60 4.62x1.87x2.16 13280 KX2500C 2272 2500 369 KX230UC2 2091 2300 422 16V4000G63/83 16V 170 210 76.3 512VL90 4.81x1.87x2.16 14235 KX2800C 2545 2800 409 KX2500UC2 2272 2500 471 20V4000G23/43 20V 170 210 95.4 531M80 5.73x2.25x2.44 17290 KX3100C 2818 3100 450 KX2750C2 2500 2750 516 20V4000G63/83 20V 170 210 95.4 531M80 5.73x2.55x2.44 18365 KX3300C 3000 3300 481 - - - - 20V4000G63L 20V 170 210 95.4 54M75 5.73x2.25x2.44 18685 - - - - KX3200UC2 2800 3200 557 20V4000G83L 20V 170 210 95.4 54M9 5.60x2.25x2.44 19241 (1) Also available in the following voltages: 415/240 V - 380/220 V - 240/120 V - 220/110 V (2) Also available in the following voltages: 440/254 V (3) PRP: main power available continuously under variable load for an unlimited number of hours annually, in accordance with ISO 8528-1 (4) ESP: Emergency Standby Power available for supplying emergency power in variable load applications in accordance with ISO 8528-1, no overload available for this service. (5) The dimensions and weights apply to a generator set specified in the price list, without options (6) Dry weight - without fuel * ISO 8528: powers specified in compliance with the legislation in force ** TA LUFT certification is given for PRP 4 Consumption OPTIMIzATION 50-60 Hz KX715 KX1750U TECHNICAL SPECIFICATIONS 50 Hz Specifications 400-230 V Generator Set Model (1) KX715 kVA Cos 0.8 PRP ESP (3) (4) 650 715 60 Hz Specifications 480-277 V Cons Generator Set Model (2) 3/4 L/h 104 - kWe ISO 8528* PRP ESP (3) (4) - - General Specifications Alternator Engine Cons 3/4 L/h Compact Version(5) Engine Type cyl Bore (mm) Stroke (mm) Cyl (L) Type Dimensions LxWxH, m Weight(6) (kg) - 12V2000G25 12V 130 150 23.9 491S4 3.98x1.63x1.95 4989 KX800 727 800 111 - - - - 12V2000G65R 12V 130 150 23.9 491M6 3.97x1.85x2.1 5262 KX880 800 880 123 - - - - 12V2000G65 12V 130 150 23.9 491L9A 3.98x1.63x1.95 5474 KX1000 910 1001 140 - - - - 16V2000G65 16V 130 150 31.8 491L10 4.33x1.84x2.19 6118 KX1100 1000 1100 152 - - - - 16V2000G65 16V 130 150 31.8 491L11 4.37x1.84x2.20 6588 KX1250 1136 1250 177 - - - - 18V2000G65 18V 130 150 35.8 502M6 4.45x2.21x2.20 7383 KX1400 1272 1400 195 - - - - 12V4000G21 12V 165 190 48.75 502L7 3.6x1.88x2.16 9778 KX1540 1400 1540 210 - - - - 12V4000G23R1 12V 170 210 57.5 502L8 4.00x1.88x2.16 10640 KX1650 1500 1650 231 - - - - 12V4000G23R2/43 12V 170 210 57.2 502VL10 4.16x1.88x2.16 10920 KX1850 1663 1830 241 X1600U 1400 1600 265 12V4000G23/43 12V 170 210 57.2 512S55 4.10x1.87x2.16 11405 KX2000 1818 2000 266 X1750U 1591 1750 301 12V4000G63/83 12V 170 210 57.2 512S55 4.10x1.87x2.16 11405 KX2200 2000 2200 306 X2000U 1818 2000 358 16V4000G23/43 16V 170 210 76.3 512M60 4.62x1.87x2.16 13280 KX2500 2272 2500 331 X2300U 2091 2300 398 16V4000G63/83 16V 170 210 76.3 512VL90 4.81x1.87x2.16 14235 KX2800 2545 2800 386 X2500U 2272 2500 452 20V4000G23/43 20V 170 210 95.4 531M80 5.73x2.25x2.44 17290 KX3100 2818 3100 420 X2750U 2500 2750 487 20V4000G63/83 20V 170 210 95.4 531M80 5.73x2.25x2.44 18365 KX3300 3000 3300 445 - - - - 20V4000G63L 20V 170 210 95.4 54M75 5.73x2.25x2.44 18685 - - - - X3200U 2800 3200 530 20V4000G83L 20V 170 210 95.4 54M9 5.73x2.25x2.44 18685 (1) Also available in the following voltages: 415/240 V - 380/220 V - 240/120 V - 220/110 V (2) Also available in the following voltages: 440/254 V (3) PRP: main power available continuously under variable load for an unlimited number of hours annually, in accordance with ISO 8528-1 (4) ESP: Emergency Standby Power available for supplying emergency power in variable load applications in accordance with ISO 8528-1, no overload available for this service. (5) The dimensions and weights apply to a generator set specified in the price list, without options (6) Dry weight - without fuel * ISO 8528: powers specified in compliance with the legislation in force 5 The CONTENERGY concept 50-60 Hz CONTENERGY ISO The CONTENERGY concept offers a range of soundproof containers featuring a multitude of options. The dimensions of CONTENERGY ISO containers comply with CSC certification. They have been specially designed to withstand significant loads and pressures during transport without incurring damage, and can be shipped without any special constraints. They are available in two sizes: 20 and 40 feet “High Cube”. With the standard dimensions, CONTENERGY containers are easy to transport and, once on site, very simple to install: we would recommend that you install them outside the building on a concrete floor plate fitted with a tunnel for the cables and pipes. CONTENERGY CIR Highly economical thanks to its cooling system, integrated sound traps and silencers, the CONTENERGY concept is completely self-contained, with a fuel capacity which enables it to operate immediately, without connection to an additional tank. CIR type containers are specially designed with mobile and rental applications in mind. This highly compact model has a very low sound level and features an optional high volume tank, giving it up to 10 hours of autonomy. This model is available as a 20 feet “High Cube” Kohler understands the many factors that have an influence on your equipment's operation. That is why our containers are designed to withstand harsh climate conditions. Whether your equipment needs to operate in extreme cold or tropical environments, let us know your requirements - we are sure to have the solution you're looking for. Our containers comply with all current standards and regulations governing these products, including: • ISO 668 • NF90-005 • NF ISO 1496-1 (ISO 8323) Trailers compliant with international standards are also available, allowing you to transform your generating set into a mobile unit. Super Silent Silent Generator Set Model 6 Engine 87-92 dB(A)@1 m 85 - 88 dB(A)@1 m 79-87dB(A)@7 m 79-82 dB(A)@7 m KX700UC2 to KX880C 12V2000 ISO 20 Si X CIR 20 SSi X KX900UC2 to KX1100C 16V2000 ISO 20 Si X CIR 20 SSi X KX1200UC2 to KX1250C 18V2000 ISO 20 Si X CIR 20 SSi X KX1540C to KX2000C 12V4000 ISO 40 Si EUR 40 Si X EUR 40 SSi KX2000UC2 to KX2500C 16V4000 ISO 40 Si EUR 40 Si X EUR 40 SSi Generator Set Controls 50-60 Hz Three control units are available in our 715 to 3300 kVA range: the M80, the KOHLER® DEC4000 control unit and the KERYS. Your control unit can be chosen according to your equipment type and perfectly adapted to suit your needs using the available options. This modularity is made even easier by the fact that each optional peripheral device (air cooler, daily service tank, oil top-up, etc.) has its own protection. For power plants, separate control boxes may be used in place of the control units: Please contact us for more information. M80 The M80 control unit has a dual functionality. It can be used as a basic terminal block for connecting a control box and as an instrument panel with a direct read facility that provides a global view of your generator set's basic parameters. Coolant temperature Tachometer Oil pressure Emergency stop button SPECIFICATIONS MEASUREMENTS ENGINE PARAMETERS CONTROLS MISCELLANEOUS • BASIC TERMINAL BLOCK M 80 Tachometer (54 mm) X • Oil pressure gauge X • Coolant temperature indicator X • Oil temperature indicator X O Emergency stop • • CE compliant • • Customer connection terminal block • • As standard X Not available O Options 7 Generator Set Controls 50-60 Hz DEC4000 The KOHLER® DEC4000 Control unit is straightforward and user-friendly, with the emphasis on communication USB connections, PC connections, control software and remote operation. The DEC4000 design offers simplicity with a reduced number of buttons to operate your generator set. ADDITIONAL Features include: • Integrated maintenance monitoring programs (on-screen display of future maintenance operations) • Built-in troubleshooting tool guides the user in the event of any alarms or faults • Ability to send e-mail, SMS or Fax in the event of any alarms or faults as an option • Optional tropical insulation of the circuit boards to provide protection in extremely humid conditions • Compliance with various requirements or regulations (CE, UL, etc.) • Screen with contrast adapted to all types of lighting • Five languages featured, with numerous other optional languages • Remote monitoring and field updates via USB connection 8 Generator Set Controls 50-60 Hz KERYS The KERYS command and control unit has been designed to fulfil the specific requirements of professionals in terms of managing and monitoring generator sets. It therefore offers a wide range of functions.This control unit is fitted as standard to all generator sets designed to be used for coupling and is offered as an option across the rest of our range.The KERYS can be built into the central console, fitted directly on the generator set, or in a separate cabinet, to fulfil all the requirements for low and high output power plants. AUTOMATIC CONTROLLER DEDICATED TO GENERATING SET APPLICATIONS •Choice of a range of basic standard configurations. •Additional logics can be added without any external tools. •Library of functional modules. FAULT FINDING HELP •Validation of operation by simulation. •Display of the status of variables. •Breakdown guide with keyword search. ASSISTANCE AND MAINTENANCE •Emails sent automatically for maintenance requests, and for the appearance of alarms or faults. •Log of operations carried out (maintenance or breakdown). LOAD IMPACTS Improvement of generating set performance during application of a significant load. GRAPHS AND ARCHIVING OF ELECTRICAL AND MECHANICAL PARAMETERS Adjustable sampling and configurable triggering criteria. COMPLIANCE WITH INTERNATIONAL STANDARDS The KERYS has undergone very stringent tests in independent laboratories (climatic tests, electromagnetic compatibility tests, vibration tests, etc.) It is CE compliant. MMI (Man-Machine Interface) Man-machine interface module The man-machine interface is available with a colour screen and a 7-inch touch panel. The MMI module is equipped with all the keys required to ensure the generator set can be controlled and the system configured, thanks to a screen navigator and an alphanumeric keypad. Display screen: 7.4 inch LCD TFT display Detailed colour display Touch screen Dimensions: 154 x 86 mm Alphanumeric keypad for setting parameters, navigation and direct access to screens Control keypad with display LEDs Manual mode selection Stop mode selection Automatic mode selection Generating set circuit breaker open/ close Test activation/deactivation Grid circuit breaker open/close LED test Horn off Clear faults Arrow keys with operation LEDs 9 Generator Set Controls 50-60 Hz FUNCTIONS GENERATOR SET AUTOMATIC CONTROL • Single generator set or as part of power plant • Operation in HT (high tension) or LT (low tension) • Normal/Emergency operation •Operation in permanent or temporary grid coupling without cut-out: • Upon return to grid power • During peak shaving • During trials or tests • Inverted emergency operation • Power production unit • Cogeneration MEASUREMENTS AND DISPLAYS Mechanical: Electrical: • Temperatures • Voltages • Pressures and levels • Currents depending on engine • Frequency and power configuration • Power factor • Outputs • Mechanical and electrical metering. SAFETY FEATURES Mechanical: Electrical: • Speed • Currents • Alarms • Voltages • Engine safety • Outputs • Special customer • Frequency features • Micro cut-outs COMMUNICATION • Built-in web server • User-friendly man-machine interface • 5 basic languages (French, English, Spanish, Portuguese, German), one of which is interchangeable (please consult us) • Ethernet Port • Dialogue with all engines equipped with a built-in ECU • RS 485 port for Modbus RTU • RS 232 port • Option of PSTN communication (Public Switched Telephone Network) CONTROLS Mechanical: • Speed • Synchronisation • Coupling • Distribution or setting of grid or generator set active power • Wattmetric programming Electrical: • Voltage • Voltage equalising • Distribution or setting of grid or generator set reactive power • Adjustment of the grid or generator set power factor (cos Phi). Inclusive of many more control parameters* display screens 10 1- Operation screen 2- Synchronisation screen 3- Graph display 4- Mechanical measurements screen * For more detailed information, refer to the KERYS documentation or contact your Kohler sales representative. AIPR SPECIFICATIONS Each generator set may be supplied with a protection unit. This unit is mounted on the chassis with connection cables to the alternator. It is located on the right-hand side of the generator set. Rating 1250 A 1600 A 2000 A 2500 A 3600 A Fixed 3-pole power circuit breaker O O O O O Fixed 4-pole power circuit breaker O O O O O With 3 or 4-pole open circuit breaker only O O O O O Voltage 208-440 V With manual control on the front Motorised control option (1) • • • • • (2) O O O O O Power connection bus bars • • • • • Remote control terminal block • • • • • Protection index IP 207 IP 207 IP 207 IP 207 IP 207 height (mm) 1260 1260 1260 1260 1260 width (mm) 683 683 683 683 683 depth (mm) 365 365 365 365 365 height (mm) 1664 1664 1664 1664 1664 width (mm) 683 683 683 683 683 depth (mm) 365 365 365 365 365 height (mm) 1883 1883 1883 1883 1883 width (mm) 683 683 683 683 683 depth (mm) 365 365 365 365 365 Auxiliary unit option DIMENSIONS (without air cooler unit) 1 DIMENSIONS (with air cooler unit) 2 DIMENSIONS (with connection unit on upper section) (1) (2) The motorised control includes a closure solenoid valve, a shunt trip coil and an AC motor The auxiliary unit option is mounted above the main unit. It is used for the power connections of generator set auxiliaries, e.g.: - air cooler output - fuel pump unit output • Standard O Option 2 11 North Asia Kohler Power Systems - Japan SBS Hills-II, No. 53 4-10-3, Yoga, Setagaya-Ku Tokyo 158-0097 Japan Tel: +81 3 6807 1730 Fax: +81 3 3708 4377 Email: kawasaki@kohler.co.jp S.E. Asia, Taiwan, Hong Kong & Bangladesh Kohler Power Systems – Singapore (Regional HQ) 7 Jurong Pier Road Singapore 619159 Tel: +65 6264 6422 Fax: +65 6264 6455 Email: sales.sg@kohler.com Australasia Kohler Power Systems – Australia C/O P O Box 324, Highgate South Australia 5063 Tel: +61 439 338 166 Fax: +61 8 8338 6424 Email: bob.morgan@kohler.com Kohler Power Systems - Korea Room 1201 Lg Twintel 2 157-3 Samsung–Dong Gangnam-Gu Seoul 135-090 Korea Tel: +82 2 563 9266 Fax: +82 2 563 9730 Email: chanusohn@kohler.com Spec your job at KohlerPower.com.SG For more information call +65 6264 6422 or visit KohlerPower.com.sg/Industrial Printed in Singapore GSF-721 04/12 ©2012 by Kohler Co. KOHLER® is a registered trademark of Kohler Co. Use of this material for reproduction on the Internet and World Wide Web is strictly prohibited without written permission from Kohler Co. 12
Similar documents
KX2500 - KohlerPower.com
basic terminal block for connecting a control box and as an instrument panel with a direct read facility, with displays giving a global view of your generating set's basic parameters. Offers the fo...
More information