Bid Documents - Northwest Michigan Health Services Inc.

Transcription

Bid Documents - Northwest Michigan Health Services Inc.
DENTAL CLINIC RENOVATION
PROJECT FOR:
NORTHWEST MICHIGAN
HEALTH SERVICES
kendra c.
THOMPSON
architects, p.c.
803 Cherry Street
Manistee, MI 49660
tel: 231.723.4195
thompson.kendra@sbcglobal.net
www.kendrathompson-architects.com
119 STATE STREET
SHELBY, MICHIGAN
BID SET
AUGUST 26, 2016
SCHEDULE OF DRAWINGS:
BID SET
8/26/2016
5
DESIGN DEVELOPMENT REV. #3
7/07/2016
4
SCHEMATIC DESIGN REV. #2
01/21/2016
3
SCHEMATIC DESIGN REV. #1
01/20/2016
2
MASTER PLAN CONCEPT
01/16/2016
1
EXISTING MAIN LEVEL PLAN
01/14/2016
NO.
REVISIONS / SUBMISSIONS
DATE
COVER SHEET
SP100
GENERAL SPECIFICATIONS
A200
A201
A202
EXISTING FLOOR PLAN
DEMOLITION PLAN
PROPOSED FLOOR PLAN AND
REFLECTED CEILING/LIGHTING PLAN
A500
INTERIOR ELEVATIONS, DETAILS AND
DOOR & ROOM FINISH SCHEDULES
MEP-1
SCHEMATIC MECHANICAL PLAN
SCHEMATIC ELECTRICAL POWER PLAN
ARCHITECT:
Kendra C. Thompson
Architects, P.C.
803 Cherry Street
Manistee, MI 49660
t: 231.723.4195
PROJECT NAME
DENTAL RENOVATION PROJECT
NORTHWEST
MICHIGAN
HEALTH
SERVICES
119 STATE STREET
SHELBY, MICHIGAN
DRAWING TITLE
COVER SHEET
SEAL
DRAWN
KCT PROJECT NO.
KCT
KT-2620B
REVIEWED
DRAWING NO.
KCT
T100
DATE
HAN. 2016
SHEET NO.
SCALE
AS NOTED
1 OF 7
Copyright 2014 Kendra C. Thompson Architects, P.C.
T100
6
188'-0" +/-
kendra c.
THOMPSON
architects, p.c.
803 Cherry Street
Manistee, MI 49660
tel: 231.723.4195
thompson.kendra@sbcglobal.net
www.kendrathompson-architects.com
COVERED
ENTRY
BREAK
ROOM
WAITING
AREA
DENTAL
#3
WOM.
TOIL.
MENS
TOIL.
WAIT'G.
TOIL.
RECEPT.
AREA
OUTREACH
STAFF
MED. LAB/
STERIL.
MEDICAL
LAB
DRAW
STATION
CLINIC
COORDINATOR
DENTAL
LAB
VITALS
STATION
DRAW
STATION
PATIENT
TOIL.
DENTAL
#2
MEDS/
MEDICAL
STOR.
DENTAL
#1
JAN.
AREA
DENTAL
STAFF
TOIL.
40'-0" +/-
CONFERENCE
ROOM
W.I.C.
DENTAL
STERIL/
LAB AREA
UNUSED
STAFF
ENTRY
M.A.
OFFICE
MEDICAL
EXAM #1
MEDICAL
EXAM #2
MEDICAL
EXAM #3
MEDICAL
EXAM #4
BEHAVIORAL
HEALTH
BID SET
8/26/2016
5
DESIGN DEVELOPMENT REV. #3
7/07/2016
4
SCHEMATIC DESIGN REV. #2
01/21/2016
3
SCHEMATIC DESIGN REV. #1
01/20/2016
2
MASTER PLAN CONCEPT
01/16/2016
1
EXISTING MAIN LEVEL PLAN
01/14/2016
NO.
REVISIONS / SUBMISSIONS
DATE
PROJECT NAME
DENTAL RENOVATION PROJECT
NORTHWEST
MICHIGAN
HEALTH
SERVICES
119 STATE STREET
SHELBY, MICHIGAN
DRAWING TITLE
N
EXISTING
MAIN LEVEL PLAN
SCALE: 1/4" = 1'-0"
EXISTING
FLOOR PLAN
SEAL
DRAWN
KCT PROJECT NO.
KCT
KT-2620B
REVIEWED
DRAWING NO.
KCT
A200
DATE
JAN 2016
SHEET NO.
SCALE
AS NOTED
3 OF 7
Copyright 2015 Kendra C. Thompson Architects, P.C.
REFERRAL
COORDIANTOR
MEDICAL
PROVIDER
OFFICE
6
kendra c.
THOMPSON
architects, p.c.
803 Cherry Street
Manistee, MI 49660
tel: 231.723.4195
thompson.kendra@sbcglobal.net
www.kendrathompson-architects.com
INDICATES EXISTING PARTITION
WALLS, DOORS, CEILINGS,
CABS & EQUIP. TO BE REMOVED
TO ACCOMMODATE NEW WORK PATCH & REPAIR AS REQ'D.
MATCHING ADJACENT SURFACES
6
BID SET
8/26/2016
5
DESIGN DEVELOPMENT REV. #3
7/07/2016
4
SCHEMATIC DESIGN REV. #2
01/21/2016
3
SCHEMATIC DESIGN REV. #1
01/20/2016
2
MASTER PLAN CONCEPT
01/16/2016
1
EXISTING MAIN LEVEL PLAN
01/14/2016
NO.
REVISIONS / SUBMISSIONS
DATE
PROJECT NAME
DENTAL RENOVATION PROJECT
NORTHWEST
MICHIGAN
HEALTH
SERVICES
119 STATE STREET
SHELBY, MICHIGAN
N
DEMOLITION
PLAN
SCALE: 1/4" = 1'-0"
DEMOLITION
PLAN
SEAL
DRAWN
KCT PROJECT NO.
KCT
KT-2620B
REVIEWED
DRAWING NO.
KCT
A201
DATE
JAN 2016
SHEET NO.
SCALE
AS NOTED
4 OF 7
Copyright 2015 Kendra C. Thompson Architects, P.C.
DRAWING TITLE
11'-0" +/-
12'-6" +/-
DENTAL
EXAM #5
DENTAL
EXAM #4
NEW
NEW
108
107
10'-0" +/-
THOMPSON
architects, p.c.
5'-0" +/-
3'-1"
CG
CG
CG
CG
EXISTING
EXISTING
EXISTING
EXISTING
103
CG
CG
CG
CG
CORRIDOR
TYPICAL NEW PARTITION:
1/2" GYP. BD. EA. SIDE OF
2X4 @ 16" O.C. W/SOUND
ATTENUATION BLANKET - EXTEND
WALLS TO HEIGHT OF EXIST'G.
EXISTING
104
5
6
A500
101A
60" H. X 48" W.
FRP PANEL @
NEW MOP SINK
NEW
MOP
SINK
CG
CG
JAN.
NEW
101
NEW
FLOOR'G.
PATIENT
TOILET
102
STAFF
AREA
(1) STAFF
STATION
SUPPLY
AREA
XRAY
NEW
803 Cherry Street
Manistee, MI 49660
tel: 231.723.4195
thompson.kendra@sbcglobal.net
www.kendrathompson-architects.com
5'-1" +/-
CG
NEW
FLOOR'G.
DENTAL
LAB
CG
NEW
FLOOR'G.
CG
SCALES
CG
106
EXISTING
kendra c.
NEW
FLOOR'G.
EXIST'G.
CLOSET
EXIST'G.
FLOOR'G.
W.I.C./MEDICAL
EXAM #1
MEDICAL
EXAM #2
MEDICAL
EXAM #3
MEDICAL
EXAM #4
MEDICAL
EXAM #5
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
N
PROPOSED
FLOOR PLAN
SCALE: 1/4" = 1'-0"
A2 (TYPICAL @ DENTAL EXAM):
2X2 LED ARCHITECTURAL TROFFER:
METALUX #22EN-LD4-34-UNV-L850-CDI-U
OR EQUAL, W/DIMMER
EXIST'G. WOOD
BEAMS TO REMAIN PAINT
8'-0"
CLG
101B
8'-0"
CLG
NEW 2' X 2' ACT W/
METAL SUSPENSION
SYSTEM @ NEW AREAS
INDICATED (TYPICAL)
INDICATES LINE OF
PL. LAM. CLOSER PANEL
@ WALL CABINETS (TYPICAL)
S1
6
BID SET
8/26/2016
5
DESIGN DEVELOPMENT REV. #3
7/07/2016
4
SCHEMATIC DESIGN REV. #2
01/21/2016
3
SCHEMATIC DESIGN REV. #1
01/20/2016
2
MASTER PLAN CONCEPT
01/16/2016
1
EXISTING MAIN LEVEL PLAN
01/14/2016
NO.
REVISIONS / SUBMISSIONS
DATE
S1
CONNECT TO
EXIST'G.
EXIST'G. CEILINGS TO
REMAIN - PATCH/REPAIR
DISTURBED AREAS
PROJECT NAME
DENTAL RENOVATION PROJECT
NORTHWEST
MICHIGAN
HEALTH
SERVICES
S3
S3
8'-0"
CLG
8'-0"
CLG
8'-0"
CLG
S3
119 STATE STREET
SHELBY, MICHIGAN
DRAWING TITLE
S3
A1 (TYPICAL @ LAB, XRAY, STAFF AREA)
2X2 LED ARCHITECTURAL TROFFER:
METALUX #22CZ-LD4-24-UNV-L835-CDI-U
OR EQUAL
CONNECT TO
EXIST'G.
FLOOR PLAN &
CLG/LTG. PLAN
SEAL
N
REFLECTED CEIL'G./
LIGHTING PLAN
SCALE: 1/4" = 1'-0"
DRAWN
KCT PROJECT NO.
KCT
KT-2620B
REVIEWED
DRAWING NO.
KCT
A202
DATE
JAN. 2016
SHEET NO.
SCALE
AS NOTED
5 OF 7
Copyright 2015 Kendra C. Thompson Architects, P.C.
EXIST'G.
CLOSET
CG
NEW
EXIST'G.
FLOOR'G.
CORRIDOR
EXIST'G.
CLOSET
CG
TYPICAL NEW CASED OPN'G:
REMOVE EXIST'G. DOOR
CASING, PROVIDE NEW
GYP. BD. CASING W/POLYMER
CORNER GUARDS WHERE
INDICATED (CG)
EXISTING
105
CG
LAB/
STERILIZATION
1
NEW
FLOOR'G.
CG
2
EXISTING
EXIST'G.
FLOOR'G.
3
A500
REF.
EXISTING
EXIST'G.
FLOOR'G.
STAFF
AREA
EXISTING
4'-0" +/-
15'-5" +/-
DENTAL
EXAM #1
CG
3'-0"
CG
6'-6 1/2" +/-
CG
DENTAL
EXAM #2
CG
EXIST'G.
FLOOR'G.
CG
NEW
FLOOR'G.
CG
NEW
FLOOR'G.
A500
SIM.
EXIST'G.
FLOOR'G.
4
9'-11" +/-
BACKER BOARD COORD. EXACT LOCATION
W/EQUIPMENT SUPPLIER
A500
UNDERC.
FREEZ.
CG
NEW
FLOOR'G.
EXIST'G.
CLOSET
4
EXIST'G.
FLOOR'G.
1"
2'-42
CG
DENTAL
EXAM #3
(3) STAFF STATIONS
7'-7 1/2" +/-
4X4 WD. POST FULL HGT. TO
STRUCTURE ABOVE COORD. EXACT LOCATION W/
EQUIPMENT SUPPLIER
EXIST'G. SPECIMEN
TRANSFER TO
REMAIN-INSTALL NEW
PLAST. LAM. COVER
TO MATCH CABS.
B12
B48
BLIND
3'-0"
kendra c.
4"H VINYL
WALL BASE
SB30
ADA COMPLIANT
W/FIN. CLOSER
PANEL
TRASH 18
B27
LAB./
2 STERILIZATION
A202 SCALE: 1/2" = 1'-0"
GYPSUM BOARD,
PAINTED
2'-10"
KNEE SPACE
4" VINYL
WALL BASE
LAB./
3 STERILIZATION
1'-8"
1'-8"
SCALES
(BY OWNER)
4" VINYL BASE
@ TOE SPACE
B24
TOWER
W3336
PLAST. LAM. COUNTER
W/4" H BACKSPL.
PLAST. LAM. CABS.
W/LOCKS (TYPICAL)
4FT POLYMER
CORNER GUARDS
THOMPSON
architects, p.c.
B27
803 Cherry Street
Manistee, MI 49660
tel: 231.723.4195
thompson.kendra@sbcglobal.net
www.kendrathompson-architects.com
LAB./
1 STERILIZATION
A202 SCALE: 1/2" = 1'-0"
A202 SCALE: 1/2" = 1'-0"
6"
PL. LAM. WALL CAB.
W/ KEYED LOCKS
PLAST. LAM.
CLOSER
GYP. BOARD,
PAINTED
CASED
OPENING
1'-10"
16" H X FULL WIDTH
FABRIC TACKBOARD
W3032
GYP. BOARD,
PAINTED
W4212 W/ PL. LAM
CLOSER PANEL
KNEE SPACE
PL. LAM. COUNTER
ON KV BRACKETS
W/MIN. (4) GROMMETS
KNEE SPACE
PLAST. LAM.
COUNTER W/
4" H. BACKSP.
(BACK & SIDE)
3'-0"
PL. LAM. COUNTER
ON KV BRACKETS
W/ MIN. (2) GROMMETS
3'-0"
16"
16"
GYP. BOARD,
PAINTED
16" H X FULL WIDTH
FABRIC TACKBOARD
PLAST. LAM.
CABINETS W/
KEYED LOCKS
2'-8"
3'-8" V.I.F.
4'-2" V.I.F.
(3) ADJUST. PL.
LAM. SHELVES ON
KV BRACKETS
(3) ADJUST. PL.
LAM. SHELVES ON
KV BRACKETS
2'-6"
4" VINYL BASE
@ TOE SPACE
SB30 W/18"
CURVED END
4" H. VINYL
WALL BASE
4" H. VINYL
WALL BASE
STAFF
6 WORK AREA
STAFF
5 WORK AREA
A202 SCALE: 1/2" = 1'-0"
NEW DENTAL
4 EXAM ROOMS
A202 SCALE: 1/2" = 1'-0"
4FT POLYMER
CORNER GUARDS
A202 SCALE: 1/2" = 1'-0"
1
2"
1"
42
1"
32
6
BID SET
8/26/2016
5
DESIGN DEVELOPMENT REV. #3
7/07/2016
4
SCHEMATIC DESIGN REV. #2
01/21/2016
3
SCHEMATIC DESIGN REV. #1
01/20/2016
2
MASTER PLAN CONCEPT
01/16/2016
1
EXISTING MAIN LEVEL PLAN
01/14/2016
NO.
REVISIONS / SUBMISSIONS
DATE
1
2"
1/2" GYP. BOARD EA. SIDE ON
2x4 WOOD STUDS @ 16" O.C.
W/SOUND ATTEN. BLANKET
(NOTE: VERIFY EXIST'G.
WALL CONSTRUCTION)
SEE
SCHEDULE
(2) 2x6 WD. HEADER
(OR AS OTHERWISE
INDICATED ON DWGS.)
SIZE
101A
JAN. ROOM
3'-0" x 7'-0" x 1 3/4"
101B
JAN. ROOM
EXIST'G. 3'-0" x 7'-0"
TYPE
1
-
MAT.
GLASS
WD
-
WD
-
TYPE
A
-
DETAIL
MAT.
FIRE
HARDW. RATING
GLASS
HEAD
JAMB
HM
-
B/A500
A/A500
1
-
-
-
-
-
2
-
REMARKS
5"
VERIFY EXIST'G.
1
DOOR TYPES:
2"
DOOR TYPE
SEE DOOR SCHEDULE
B HEAD
A200 SCALE: 3" = 1'-0"
2"
CL'G
MT'L
101
JANITOR ROOM
4" VINYL
LVT PLANKS
GYP. BD., PAINT
EXIST'G.
102
XRAY AREA
MATCH EXIST'G.
LVT PLANKS
GYP. BD., PAINT
NEW 2X2 ACT
103
STAFF AREA
4" VINYL
LVT PLANKS
GYP. BD., PAINT
NEW 2X2 ACT
GYP. BD., PAINT
EXIST'G.
GYP. BD., PAINT
EXIST'G.
104
CORRIDOR, SOUTH
MATCH EXIST'G.
105
CORRIDOR, NORTH
MATCH EXIST'G.
EXIST'G. TO
REMAIN U.N.O.
NEW LVT @ EAST END,
EXIST'G. OTHERWISE
106
LAB/STERILIZATION
4" VINYL
LVT PLANKS
GYP. BD., PAINT
NEW 2X2 ACT
107
DENTAL EXAM #4
4" VINYL
LVT PLANKS
GYP. BD., PAINT
NEW 2X2 ACT
108
DENTAL EXAM #5
4" VINYL
LVT PLANKS
GYP. BD., PAINT
NEW 2X2 ACT, EXIST'G.
WOOD BMS-PAINT
SCHEDULE
REMARKS
COORDINATE NEW CLG, FLOOR'G &
WALL BASE W/EXIST'G.
COORDINATE NEW INFILL WALL W/
EXIST'G FINISHES
COORDINATE NEW WORK W/
EXIST'G FINISHES
5"
WALL
MT'L
1/2" GYP. BOARD EA. SIDE ON
2x4 WOOD STUDS @ 16" O.C.
W/SOUND ATTEN. BLANKET
(NOTE: VERIFY EXIST'G. WALL
CONSTRUCTION)
1
2"
FLOOR
MT'L
DOOR TYPE
SEE DOOR SCHEDULE
2x4 WOOD NAILER
1
2"
WALL
BASE
1"
42
1"
32
ROOM
NAME
A
FRAME TYPES:
NORTHWEST
MICHIGAN
HEALTH
SERVICES
HOLLOW METAL FRAME
SEE
SEE SCHEDULE
ROOM NO.
ROOM FINISH SCHEDULE
DENTAL RENOVATION PROJECT
A JAMB
2"
A200 SCALE: 3" = 1'-0"
HOLLOW METAL FRAME
119 STATE STREET
SHELBY, MICHIGAN
DRAWING TITLE
INT. ELEV. &
SCHEDULES
SEAL
DRAWN
KCT PROJECT NO.
KCT
KT-2620B
REVIEWED
DRAWING NO.
KCT
A500
DATE
JAN. 2016
SHEET NO.
SCALE
AS NOTED
6 OF 7
Copyright 2015 Kendra C. Thompson Architects, P.C.
LOCATION
FRAME
2"
DOOR
PROJECT NAME
SEE SCHEDULE
DOOR NO.
DOOR SCHEDULE
2"
SB24
CASED
OPENING
W2136
PLAST. LAM.
COUNTER W/
4" H. BACKSP.
1'-10"
3'-0"
UNDERCOUNTER
FREEZER
24" WIDE
(BY OWNER)
W4236
2'-10"
5'-8"
STERILIZER
(BY OWNER)
REFRIDGERATOR
30" WIDE
(BY OWNER)
W3336
BLIND
1'-8"
GYP. BOARD,
PAINTED
4'-0"
8'-0"
(3) EQUAL W6236
ADJUST.
SHELVES
8'-0"
W3324
AUTOCL.
(BY OWNER)
3'-0"
3'-0"
(3) 12" D. PLAST.
LAMINATE SHELVES
ON METAL KV
BRACKETS
3'-0"
PLAST. LAM.
CABINETS W/
KEYED LOCKS
6"
4"
6"
4"
1'-10"
PLAST. LAM.
CLOSER
2'-0"
PLAST. LAM.
CLOSER PANEL
DENTAL CHAIR & EQUIP: CONTRACTOR TO PROVIDE
ALL REQ'D. AIR, VACUUM AND WATER CONNECTIONS
AS REQ'D. TO ACCOMMODATE NEW DENTAL CHAIR EQUIPMENT
(PATTERSON: A-DEC #411, 332, 551 & 561 EQUIPMENT)
PROVIDE 2" COPPER AIR LINES TO EXISTING AIR COMPRESSOR,
2" PVC SCH. 40 RISER THRU FLOOR TO EXISTING VACUUM FURNISH ALL CODE COMPLIANCE SHUT-OFF VALVES AS REQ'D.
DENTAL
EXAM #5
DENTAL
EXAM #4
DENTAL
EXAM #3
DENTAL
EXAM #2
DENTAL
EXAM #1
EXISTING
EXISTING
EXISTING
EXIST'G.
CLOSET
S-3: 1-COMP. STAIN. STL. BOWL SINK
14 3/8" DIA. ELKAY #RLLVR12, TOP MTD., ADA
W/AMERICAN STANDARD #6275.000.1424
9" GOOSENECK FAUCET, REMOV. STRAINER,
CHROME STOPS 1/4 TURN SUPPLIES & P-TRAP
STAFF
AREA
803 Cherry Street
Manistee, MI 49660
tel: 231.723.4195
thompson.kendra@sbcglobal.net
www.kendrathompson-architects.com
XRAY
EXISTING
PROVIDE ICE MAKER
VALVE BOX EQUAL TO
GUY GRAY W9700 W/
1/4" TURN BALL VALVES
EXISTING
THOMPSON
architects, p.c.
EXISTING
DENTAL
LAB
LAB/
STERILIZATION
RECEPTION
kendra c.
CORRIDOR
PATIENT
TOILET
SUPPLY
AREA
STAFF
AREA
EXISTING
EXISTING
EXISTING
JAN.
EXIST'G.
CLOSET
S-1: 1-COMP. STAIN. STL. SINGLE BASIN
25"X 21" X5 3/8" DP, 20-GA, ADA W/AMERICAN
STANDARD #6275.000.1424 9" GOOSENECK
FAUCET, REMOV. STRAINER, CHROME STOPS,
1/4 TURN SUPPLIES & P-TRAP
CORRIDOR
EXIST'G.
CLOSET
S-2: 1-COMP. STAIN. STL. SINGLE BASIN
19" X 19" 5" DP, 20-GA, ADA W/AMERICAN
STANDARD #6275.000.1424 9" GOOSENECK
FAUCET, REMOV. STRAINER, CHROME STOPS,
1/4 TURN SUPPLIES & P-TRAP
EXISTING
S-4: MOP SINK
PROFLO PFMB2424
W/AMERICAN STANDARD
#8344.111 WALL MOUNT
FAUCET TOP BRACE,
VACUUM BREAKER, STOPS,
HOSE & HOSE CARRIER
EXIST'G.
CLOSET
W.I.C./MEDICAL
SCHEMATIC
MECH. PLAN
MEDICAL
MEDICAL
N
MEDICAL
MEDICAL
SCALE: 1/4" = 1'-0"
XRAY: 120V 5 AMP DEDICATED POWER
PROVIDE CONDUIT TO REMOTE SWITCH
@ CORRIDOR WALL)
QUAD FLOOR BOX:
120V 5 AMP 4-PLEX DEDICATED POWER
W/COMMUNICATION CHASE BELOW FLOOR
BTWN. CHAIR & WALL MONITOR CONTROLS
(BOX BY EQUIP. SUPPLIER, ALL
CONNECTIONS BY ELECT. CONTRACTOR)
WALL MTD. MONITOR/KEYBD:
120V, 8 AMP DUPLEX RECEPTACLE
PROVIDE CONDUIT BTWN. MONITOR & CHAIR
DENTAL
EXAM #4
@ 18"
@ 18"
DENTAL
EXAM #2
DENTAL
EXAM #1
EXISTING
EXISTING
EXISTING
@ 18"
@ 18"
EXIST'G.
CLOSET
GFI-A.C.
GFI-A.C.
EM: EMERGENCY FIXTURE
LED W/ BATTERY BACKUP
& (2) LTG HEADS
EX: EXIT FIXTURE
LED, WALL MTD.
@ 18"
LOW-VOLTAGE OPERATOR
FOR XRAY @ 44"AFF W/
NON-LOCKING HINGED
COVER BOX - COORD. W/
XRAY EQUIP. CONTRACTOR
EXIST'G. EXIT LIGHT
TO REMAIN (V.I.F.)
(1) 120V, 20A @ 30"AFF
(1) 120V, 20A @ 48"AFF
RECEPTION
DENTAL
EXAM #3
STAFF
AREA
GFI-A.C.
U.C. FREEZER @ 18" AFF
GFI-A.C.
@ 18"
SCALES:
@ 18"
LAB/
STERILIZATION
GFI-A.C.
GFI-A.C.
REFR: @ 18" AFF
GFI-A.C.
GFI-A.C.
5
DESIGN DEVELOPMENT REV. #3
7/07/2016
4
SCHEMATIC DESIGN REV. #2
01/21/2016
3
SCHEMATIC DESIGN REV. #1
01/20/2016
2
MASTER PLAN CONCEPT
01/16/2016
1
EXISTING MAIN LEVEL PLAN
01/14/2016
NO.
REVISIONS / SUBMISSIONS
DATE
EXISTING
DENTAL
LAB
XRAY
PROJECT NAME
DENTAL RENOVATION PROJECT
NORTHWEST
MICHIGAN
HEALTH
SERVICES
@18"
EXISTING
SUPPLY
AREA
PATIENT
TOILET
LOW-VOLTAGE OPERATOR
FOR XRAY @ 44"AFF W/
NON-LOCKING HINGED
COVER BOX - COORD. W/
XRAY EQUIP. CONTRACTOR
@18"
@18"
EXISTING
STAFF
AREA
@18"
EX: EXIT FIXTURE
LED, WALL MTD.
EXISTING
@18"
EXISTING
@18"
CORRIDOR
EXISTING
EXIST'G.
CLOSET
@18"
EXIST'G.
CLOSET
8/26/2016
CORRIDOR
GFI-A.C.
EXISTING
BID SET
EXIST'G.
CLOSET
JAN.
XRAY EQUIP.:
120V, 15A
DEDICATED OUTLET
COORDINATE W/
EQUIP. CONTRACTOR
TYPICAL DATA BOX:
ELECT. CONTRACTOR TO
PROVIDE BLANK BOX W/
1" CONDUIT STUBBED
ABOVE CEIL'G. - COVER
& CABLING BY OWNER
EX: EXIT FIXTURE
LED, SIDE WALL MTD.
119 STATE STREET
SHELBY, MICHIGAN
DRAWING TITLE
SCHEMATIC
MEP PLANS
SEAL
W.I.C./MEDICAL
MEDICAL
N
SCHEMATIC
ELECTRICAL PLAN
MEDICAL
SCALE: 1/4" = 1'-0"
MEDICAL
MEDICAL
DRAWN
KCT PROJECT NO.
KCT
KT-2620B
REVIEWED
DRAWING NO.
KCT
MEP-1
DATE
JAN. 2016
SHEET NO.
SCALE
AS NOTED
7 OF 7
Copyright 2015 Kendra C. Thompson Architects, P.C.
DENTAL
EXAM #5
6
GENERAL SPECIFICATIONS
DIVISION 6 - WOOD AND PLASTICS
Wood Framing
All wood members shall be minimum 1050 psi bending stress materials, dressed lumber of S4S grade,
(No. 2 Douglas Fir, Hem Fir or better) w/maximum 19% moisture content at time of dressing. Lumber in
contact with concrete, masonry or earth shall be treated for contact of such. Install 1/2" compressible
fiberglass blanket sill sealer at all sill plates.
Finish Wood, interior
All interior finish wood, including but not limited to baseboards, door casings and other misc. finish
trim shall be coordinated with Owner. It is the intent to match existing trim profiles where appropriate.
Finish Carpentry, miscellaneous components
Furnish and install miscellaneous finish carpetry items, including shelf and counter brackets as indicated
on drawings. Shelf standards shall be 12 ga. anochrome finish #87 ANO manufactured by Knape and
Vogt. Shelf brackets shall be 12 ga. heavy duty anachrome finish #187LL by Knape and Vogt. All
shelving and miscellaneous elements shown on drawings to be plastic laminate shall be shop fabricated
plastic laminate face with laminate backing sheets on unexposed surfaces on medium density fiberboard
(MDF) ANSI A208.2 with adhesive as specified by AWI standards. Plastic laminate color shall be
selected by Architect from manufacturer's full range of colors, as manufactured by Formica, Wilsonart
or approved equal. Submit shop drawings to Architect for review/approval prior to construction.
Architectural Casework
Furnish and install architectural casework as indicated on drawings. Casework shall be specially
fabricated cabinet units consisting of high-pressure plastic laminate (0.048 HDPL) over 3/4-inch
medium-denisty fiberboard (MDF) ANSI A208.2 with adhesive as specified by AWI standards. Plastic
laminate at exposed surfaces shall be selected by Architect from manufacturer's full range of colors, as
manufactured by Formica, Wilsonart or approved equal. Cabinet liner which are closed to view by
doors may be "melamine" type panels. All other exposed surfaces, including tops and bottoms of wall
hung cabinets, shall be HPDL. Drawer bottom, dust panels and similar shall be constructed using
hardwood meeting AHA A135.4, pressed wood fiber with resin binder, Class I-tempered, 1/4-inch,
smooth two sides. Construction shall include European style door/drawer hardware with full extension
and self-closing mechanism. Casework shelving shall include adjustable shelf supports using multiple pin
supports and coordinating rest supports with 1-inch spacing adjustment. Casework hardware shall be
standard wire "C" pulls, 4-inch o.c., brushed aluminum finish. All casework shall be provided with
standard keyed locks. Cabinet supplier shall coordinate all work and requirements with General
Contractor. Submit shop drawings to Architect for review/approval prior to construction.
Countertops: Plastic Laminate
Furnish and install countertops as indicated on drawings. Plastic laminate countertops shall be
high-pressure plastic laminate (0.048 inch HPDL) selected from manufacturer's full range of colors as
manufactured by Formica, Wilsonart or approved equal. Plastic laminate countertops shall be 3/4-inch
medium density fiberboard (MDF) substrate covered with HDPL, conventionally fabricated with HDPL
edges. Provide backsplash of same construction where indicated on drawings. Submit product
information to Architect for final color selection.
Fiberglass Reinforced Panel (FRP)
Furnish and install FRP panel at wall surface surrounding Janitor mop sink area. FRP panel shall extend
from top of mop sink to 60-inch height above floor. FRP panel shall be adhered to gypsum board
substrate. Provide standard FRP sheet, minimum 0.090-inch thickness, pebble finish as manufactured
by Marlite or approved equal. Provide all required trims and accessories for a complete installation.
DIVISION 7 - THERMAL AND MOISTURE PROTECTION
Sealants
Install sealant and backer rod where required to seal any joints, dissimilar material transitions and for
watertightness. All interior sealants shall be acrylic latex or approved equal. Where required, exterior
sealant shall be nonsag, polyurethane capable of continuous water immersion. Colors to match
adjacent surfaces. Install sealant isolation at dissimilar metal connections. Install acoustic sealant at all
new interior partitions.
DIVISION 8 - DOORS AND WINDOWS
Interior Flush Wood Doors
Furnish and install pre-hung wood frame, flush interior wood doors as indicated on drawings.
Acceptable manufacturer's are Graham Doors, Marshfield Doors or approved equal. Doors shall be
1-3/4 inch thick, with honey-comb core and face veneer maple species, rift cut with slip-matched grain
with edges of same species. Construct and finish doors in accordance with AWI standards. Doors
shall be factory machined for finish hardware. Factory finish doors in accordance with AWI Quality
Standards Section 1500 for transparent catalyzed polyurethane, satin sheen. Install doors per
manufacturer's instructions and AWI standards. Coordinate final species and finish with Owner.
Hollow Metal Frames
Furnish and install hollow metal frames where indicated on drawings. Frames shall be factory primed
with rust inhibiting primer complying with ANSI A250.10, ready for field finishing. HM frames shall be
14 ga frames. All frames shall be equipped with resilient rubber silencers, 3 on strike side of single
door. Frames indicated to be fire-rated shall bear the certification plate of UL or other approved
testing agency for rating specified. Prep for door hardware in accordance with BHMA A 156.115
with reinforcement welded in place.
Hardware
All door hardware shall meet the requirements of the Michigan Barrier-Free and ADA regulations (lever
type or equal). Finishes to be standard US26D/BHMA 626 dull chrome or equal. Keying per Owner.
Standard of goods shall be Schlage D-series locksets, LCN closers, Stanley hinges or approved equal.
Hardware Set 1:
(3) Hinges
(1) Storage Lockset
(1) Surface Closer
(1) Wall Stop
(1) Kickplate
(3) Silencers
5BB1 4.5x4.5
ND 80 PD
4011
WSA407 CCV
K3125 10" x 2" LDW
SR64
kendra c.
THOMPSON
architects, p.c.
803 Cherry Street
Manistee, MI 49660
tel: 231.723.4195
thompson.kendra@sbcglobal.net
www.kendrathompson-architects.com
Ive
Schlage
LCN
Ive
Rock
Ive
Hardware Set 2: Existing hardware to remain, except install new:
(1) Storage Lockset ND 80 PD
Schlage
DIVISION 9 - FINISHES
Gypsum Board
Furnish and install standard paper-faced gypsum board ASTM C1396 as manufactured by US Gypsum
or approved equal. Provide 1/2-inch minimum thickness at walls, 5/8-inch at all ceiling construction and
5/8-inch Type 'X' fire-rated where indicated on drawings. Provide all cornerbeads, casing beads and
other miscellaneous trim as required for a neat and complete installation. All gypsum board shall be
glued and fastened with screws. Screws shall be self-tapping type located at 12" o.c. Install product
in strict accordance with manufacturers instructions. Provide Level 4, ready for painting.
Acoustic Ceilings and Metal Suspension System
Furnish and install suspended metal grid ceiling system and acoustic ceiling panels as indicated on
drawings. Acoustic ceiling panels shall be as follows:
ACT-1: "Cortega" as manufactured by Armstrong World Industries
Size: 24 inch by 24 inch by 5/8-inch thickness
Edge: Reveal edge
Surface Color: White
Surface Pattern: Non-directional fissured
Metal suspension system shall be manufactured by same as acoustic panel units, equal to "Prelude XL"
15/16-inch tee system by Armstrong World Industries. Suspension system shall comply with ASTM
C635 die-cut, interlocking components complete with stabilizer bars, clips, edge trim and all
accessories to provide a complete installation. Installation shall be in accordance with ASTM C 636,
ASTM E 580 and manufacturer's instructions. Hold-down clips shall be installed on acoustic panels
within 20 feet of an exterior door. Submit product information to Architect for review/approval prior
to construction.
Vinyl Plank Flooring (LVT) and Wall Base
Furnish and install LVT (vinyl plank) flooring and resilient wall base where indicated on Room Finish
Schedule and drawings. LVT shall be "Freelay Heritage Wood" as manufactured by Milliken Co., color:
HER-208, or approved equal. Vinyl flooring shall be 9-inch wide x 60-inch length, installed randomly.
Provide 28 mil wear layer, 5 mm overall product thickness. LVT shall comply with ASTM F970 for
static load limit. Flooring shall comply with ADA requirements for slip-resistance. Installation of LVT
shall be free lay with perimeter adhesive in accordance with manufacturer's installation
recommendations. Resilient base shall be ASTM F 1861, Type TS rubber. Provide resident base of
4-inch by 0.125-inch thick, satin finish with premolded external corners and end stops as manufactured
by Johnsonite, Roppe or approved equal. Colors to be selected from full range of colors. Install in
accordance with manufacturer's instructions. Submit product information for Architect review/approval
prior to construction.
Painting
All interior surfaces shall receive finish paint or stain. Color as selected by Owner. Where painting is
required use the following schedule:
Interior Gypsum:
Interior Wood, painted:
Interior Wood, stained:
6
BID SET
8/26/2016
5
DESIGN DEVELOPMENT REV. #3
7/07/2016
4
SCHEMATIC DESIGN REV. #2
01/21/2016
3
SCHEMATIC DESIGN REV. #1
01/20/2016
2
MASTER PLAN CONCEPT
01/16/2016
1
EXISTING MAIN LEVEL PLAN
01/14/2016
NO.
REVISIONS / SUBMISSIONS
DATE
Primer - 1 coat - Latex Base Primer; Finish - 2 coat - Satin Latex
Primer - 1 coat - Latex Base Primer; Finish - 2 coat - Satin Latex
Stain - 1 coat - Color selected by Owner; Sealer - 2 coat - Polyurethane
PROJECT NAME
Standard of Goods: Sherwin Williams; Martin Seynour; Valspar or approved equal.
DIVISION 10 - EQUIPMENT
DENTAL RENOVATION PROJECT
NORTHWEST
MICHIGAN
HEALTH
SERVICES
Corner Guards
Furnish and install surface-mounted polymer cover corner guards similar to Acrovyn 4000 Model
#SSM-20N, or approved equal. Corner guards shall be install where indicated on drawings. Assembly
shall consist of manufacturer's standard prefabricated unit of snap-on, resilient plastic cover installed
over retainer, including mounting hardware. Cover shall be extruded rigid plastic, minimum 0.078-inch
wall thickness, 2-inches wide with 1/4-inch radius corner. Retainer clips shall be manufacturer's
standard non-corrosive impact absorbing clips. Top and bottom caps shall be prefabricated
manufacturer's standard matching cover color. Color shall be selected by Architect from manufacturer's
full range of colors.
119 STATE STREET
SHELBY, MICHIGAN
DIVISION 15 - MECHANICAL & DIVISION 16 - ELECTRICAL
DRAWING TITLE
Mechanical, plumbing and electrical work shall be developed on a design-build arrangement. Design
and installation shall be in strict compliance with the latest edition of the Michigan Mechanical Code,
Michigan Plumbing Code-Part 7, National Electric Code and other federal, state and local requirements
as they may apply. Trade contractors shall coordinate all work and associated requirements with
General Contractor and related trades.
GENERAL
SPECS
Drawings reflect general design intentions and are for establishing the schematic scope of work only.
Trade contractors shall aquaint themselves with the existing conditions to determine work requirements
for completing the design renovations proposed. Owner equipment contractor will provide equipment
shop drawings prior to construction for trade contractors use in determining final equipment
requirements, locations and template diagrams.
SEAL
DRAWN
KCT PROJECT NO.
KCT
KT-2620B
REVIEWED
DRAWING NO.
KCT
DATE
JAN. 2016
SP100
SHEET NO.
SCALE
AS NOTED
2 OF 7
Copyright 2015 Kendra C. Thompson Architects, P.C.
DIVISION 0 - CONDITIONS OF THE CONTRACT
Scope of the Work
The scope of work includes, but not limited to, the furnishing materials and providing labor to complete
all work required for the proposed interior renovation project to accommodate two new dental exam
and lab/sterilization area at the existing facilities for Northwest Michigan Health Services located at 119
S. State Street, Shelby, Michigan.
Governing Regulations
All Work shall be performed in strict conformance with State of Michigan Building Code (IBC 2012, as
amended), Michigan Barrier-free Regulations, Americans with Disabilities Act (ADA) as applicable and
most current editions of the Michigan Mechanical Code, Michigan Plumbing Code, National Electrical
Code, National Fire Protection Code (NFPA) and other state and local regulations as they may apply.
Licensing and Permit Fees
General and trade contractors shall be licensed by the State of Michigan for their respective trade.
Contractors are responsible for obtaining and paying for required permits and inspections as
associated with their respective trade.
Insurance
Contractors shall provide Certificate of Insurance covering statuary insurance requirements for
workman's compensation insurance and other as applicable. Provide general liability insurance of
$1,000,000 minimum per occurance. The Owner and Architect shall be named as co-insured for the
duration of the project.
Product Samples and Substitutions
It shall be required that the contractor submit material samples and shop drawings for the primary
components of this project to the Architect. Additionally, Contractor shall complete all work in
accordance with equipment supplier's shop drawing submittals. Where specific materials are specified,
provide only that product unless approved prior to installation by the Architect. Colors to be selected
by Architect from manufacturer's standard range of colors.
Drawings
Do NOT scale drawings. Use dimensional figures only. Contractor shall verify all dimensions prior to
construction and shall be responsible for same. Notify Architect immediately of any discrepancies,
dimensional errors, or existing conditions that effect the design intent. Dimensional figures are from
face of wall to face of wall, typically.
DIVISION 1 - GENERAL REQUIREMENTS
Building Information
B, business
Use Group:
Square Footage,
4,785 s.f. gross exterior
Overall Existing:
560 s.f. gross interior
Renovation Area:
5B, combustible, non-protected
Construction Type:
None
Fire Suppression:
45 persons
Occupancy: