Haskris Brochure (revised December-02)
Transcription
Haskris Brochure (revised December-02)
Water Recirculating Systems Haskris water recirculating systems are designed to provide a continuous supply of clean, temperature controlled fluid to your water cooled equipment. Haskris specializes in custom designs. Please contact us to discuss your special requirements and let us design a system tailored to your application. click on Refrigerated Models 100 Kelly Street, Elk Grove Village, IL 60007, Ph: 847-956-6420 Fax: 847-956-6595, info@haskris.com Non - Refrigerated Models click for home page Refrigerated Water Recirculating Systems 100 Kelly Street, Elk Grove Village, IL 60007, Ph: 847-956-6420 Fax: 847-956-6595, info@haskris.com Model Cooling Capacity Details R033 Up Up To To 1200 Watts (4090 Btu/Hr) Click Button For Tech Specs R050 Up Up To To 1750 Watts (5970 Btu/Hr) Click Button For Tech Specs R075 UpUp ToTo 3000 Watts (10,230 Btu/Hr) Click Button For Tech Specs R100 UpUp ToTo 3850 Watts (13,125 Btu/Hr) Click Button For Tech Specs R175 UpUp ToTo 6500 Watts (22,165 Btu/Hr) Click Button For Tech Specs R250 UpUp To To 8500Watts (28,985 Btu/Hr) Click Button For Tech Specs R300 Up UpTo To 11,000 Watts (37,510 Btu/Hr) Click Button For Tech Specs R400 UpTo To Up 13,500 Watts (46,025 Btu/Hr) Click Button For Tech Specs R500 UpTo To Up 17,000 Watts (57,975 Btu/Hr) Click Button For Tech Specs R550 UpTo To Up 19,500 Watts (66,500 Btu/Hr) Click Button For Tech Specs R750 Up UpTo To 25,000 Watts (85,250 Btu/Hr) Click Button For Tech Specs R1000 Up To 33,000 Watts (112,530 Btu/Hr) Click Button For Tech Specs click for home page Model R033 100 Kelly Street, Elk Grove Village, IL 60007 Ph: 847-956-6420 Fax: 847-956-6595, info@haskris.com with air cooled condenser Cooling Capacity ( at 65°F supply water temp. ) Compressor HP Refrigerant Water Pump Capacity several alternatives available Pump Motor HP Reservoir Volume Power Requirements* Dimensions several alternatives available ( W x D x H ) in. Shipping Weight Refrigerated Water Recirculating Systems Watts Btu/Hr 950 3,240 with water cooled condenser Watts Btu/Hr 1,200 4,090 1/3 1/3 R134a R134a 1 GPM (3.8 LPM) 1 GPM (3.8 LPM) 1/3 1/3 5 Gallons (19 Liters) 5 Gallons (19 Liters) 115V-1 -60Hz 115V-1 -60Hz 18 x 27 x 29 18 x 27 x 29 250 Lbs. (113 Kgs.) 250 Lbs. (113 Kgs.) • Cooling capacity of air cooled units based on 80°F ambient air temperature. Changes in air temperature will affect cooling capacity. • Unit specifications will change by adding certain options. * Also available in 50Hz Available Options c l i c k Similar Models (Click) Custom Design c l i c k Non - Refrigerated Models c l i c k R033 R050 R075 R100 R175 R250 R300 R400 R500 R550 R750 R1000 click for home page Model R050 Refrigerated Water Recirculating Systems 100 Kelly Street, Elk Grove Village, IL 60007 Ph: 847-956-6420 Fax: 847-956-6595, info@haskris.com with air cooled condenser Cooling Capacity Watts Btu/Hr ( at 65°F supply water temp. ) Compressor HP several alternatives available Power Requirements* Dimensions several alternatives available ( W x D x H ) in. Shipping Weight 115V-1 1,750 5,970 1/2 R134a R134a 1 GPM (3.8 LPM) 1 GPM (3.8 LPM) 1/3 1/3 5 Gallons (19 Liters) 5 Gallons (19 Liters) Pump Motor HP Reservoir Volume Watts Btu/Hr 1,400 4,775 1/2 Refrigerant Water Pump Capacity with water cooled condenser -60HZ or 208/230V-1 -60Hz 115V-1 -60HZ or 208/230V-1 18 x 27 x 29 18 x 27 x 29 250 Lbs. (113 Kgs.) 250 Lbs. (113 Kgs.) -60Hz • Cooling capacity of air cooled units based on 80°F ambient air temperature. Changes in air temperature will affect cooling capacity. • Unit specifications will change by adding certain options. * Also available in 50Hz Available Options c l i c k Similar Models (Click) Custom Design c l i c k Non - Refrigerated Models c l i c k R033 R050 R075 R100 R175 R250 R300 R400 R500 R550 R750 R1000 click for home page Model R075 100 Kelly Street, Elk Grove Village, IL 60007 Ph: 847-956-6420 Fax: 847-956-6595, info@haskris.com with air cooled condenser Cooling Capacity ( at 65°F supply water temp. ) Compressor HP Refrigerant Water Pump Capacity several alternatives available Pump Motor HP Reservoir Volume Power Requirements* Dimensions several alternatives available ( W x D x H ) in. Shipping Weight Refrigerated Water Recirculating Systems Watts Btu/Hr 2,200 7,500 with water cooled condenser Watts 3,000 Btu/Hr 10,230 3/4 3/4 R134a R134a 1.7 GPM (6.4 LPM) 1.7 GPM (6.4 LPM) 1/3 1/3 6 Gallons (23 Liters) 6 Gallons (23 Liters) 208/230V-1 208/230V-1 -60Hz -60Hz 21 x 29 x 32 21 x 29 x 32 350 Lbs. (159 Kgs.) 350 Lbs. (159 Kgs.) • Cooling capacity of air cooled units based on 80°F ambient air temperature. Changes in air temperature will affect cooling capacity. • Unit specifications will change by adding certain options. * Also available in 50Hz Available Options c l i c k Similar Models (Click) Custom Design c l i c k Non - Refrigerated Models c l i c k R033 R050 R075 R100 R175 R250 R300 R400 R500 R550 R750 R1000 click for home page Model R100 100 Kelly Street, Elk Grove Village, IL 60007 Ph: 847-956-6420 Fax: 847-956-6595, info@haskris.com with air cooled condenser Cooling Capacity ( at 65°F supply water temp. ) Compressor HP Refrigerant Water Pump Capacity several alternatives available Pump Motor HP Reservoir Volume Power Requirements* Dimensions several alternatives available ( W x D x H ) in. Shipping Weight Refrigerated Water Recirculating Systems Watts Btu/Hr 3,150 10,740 with water cooled condenser Watts 3,850 Btu/Hr 13,125 1 1 R134a R134a 1.7 GPM (6.4 LPM) 1.7 GPM (6.4 LPM) 1/3 1/3 6 Gallons (23 Liters) 6 Gallons (23 Liters) 208/230V-1 208/230V-1 -60Hz -60Hz 21 x 29 x 32 21 x 29 x 32 350 Lbs. (159 Kgs.) 350 Lbs. (159 Kgs.) • Cooling capacity of air cooled units based on 80°F ambient air temperature. Changes in air temperature will affect cooling capacity. • Unit specifications will change by adding certain options. * Also available in 50Hz Available Options c l i c k Similar Models (Click) Custom Design c l i c k Non - Refrigerated Models c l i c k R033 R050 R075 R100 R175 R250 R300 R400 R500 R550 R750 R1000 click for home page Model R175 100 Kelly Street, Elk Grove Village, IL 60007 Ph: 847-956-6420 Fax: 847-956-6595, info@haskris.com with air cooled condenser Cooling Capacity ( at 65°F supply water temp. ) Refrigerated Water Recirculating Systems Watts Btu/Hr 5,500 18,750 with water cooled condenser Watts 6,500 Btu/Hr 22,165 Compressor HP 1.75 1.75 Refrigerant R22 R22 3.7 GPM (14.1 LPM) 3.7 GPM (14.1 LPM) 1/3 1/3 9 Gallon (34 Liters) 9 Gallon (34 Liters) Water Pump Capacity several alternatives available Pump Motor HP Reservoir Volume Power Requirements* Dimensions several alternatives available ( W x D x H ) in. Shipping Weight 208/230V-1 -60Hz 208/230V-1 -60Hz 27 x 26 x 35 27 x 26 x 35 425 Lbs. (193 Kgs.) 425 Lbs. (193 Kgs.) • Cooling capacity of air cooled units based on 80°F ambient air temperature. Changes in air temperature will affect cooling capacity. • Unit specifications will change by adding certain options. * Also available in 50Hz Available Options c l i c k Similar Models (Click) Custom Design c l i c k Non - Refrigerated Models c l i c k R033 R050 R075 R100 R175 R250 R300 R400 R500 R550 R750 R1000 click for home page Model R250 Refrigerated Water Recirculating Systems 100 Kelly Street, Elk Grove Village, IL 60007 Ph: 847-956-6420 Fax: 847-956-6595, info@haskris.com with air cooled condenser Cooling Capacity Watts Btu/Hr ( at 65°F supply water temp. ) with water cooled condenser Watts 8,500 Btu/Hr 28,985 7,500 25,575 Compressor HP 2.5 2.5 Refrigerant R22 R22 3.7 GPM (14.1 LPM) 3.7 GPM (14.1 LPM) 1/3 1/3 14 Gallons (53 Liters) 14 Gallons (53 Liters) Water Pump Capacity several alternatives available Pump Motor HP Reservoir Volume Power Requirements* Dimensions several alternatives available ( W x D x H ) in. Shipping Weight 208/230V-1 -60Hz or 208/230V-3 -60Hz 208/230V-1 -60Hz or 208/230V-3 35 x 31 x 48 27 x 26 x 43 750 Lbs. (340 Kgs.) 525Lbs. (238 Kgs.) -60Hz • Cooling capacity of air cooled units based on 80°F ambient air temperature. Changes in air temperature will affect cooling capacity. • Unit specifications will change by adding certain options. * Also available in 50Hz Available Options c l i c k Similar Models (Click) Custom Design c l i c k Non - Refrigerated Models c l i c k R033 R050 R075 R100 R175 R250 R300 R400 R500 R550 R750 R1000 click for home page Model R300 Refrigerated Water Recirculating Systems 100 Kelly Street, Elk Grove Village, IL 60007 Ph: 847-956-6420 Fax: 847-956-6595, info@haskris.com with air cooled condenser Cooling Capacity Watts Btu/Hr ( at 65°F supply water temp. ) Compressor HP several alternatives available 3 R22 R22 7.9 GPM (30.0 LPM) 7.9 GPM (30.0 LPM) 3/4 3/4 14 Gallons (53 Liters) 14 Gallons (53 Liters) Pump Motor HP Reservoir Volume Power Requirements* Dimensions several alternatives available ( W x D x H ) in. Shipping Weight 208/230V-1 Watts 11,000 Btu/Hr 37,510 10,000 34,100 3 Refrigerant Water Pump Capacity with water cooled condenser -60Hz or 208/230V-3 -60Hz 208/230V-1 -60Hz or 208/230V-3 35 x 31 x 48 30 x 26 x 43 750 Lbs. (340 Kgs.) 600 Lbs. (272 Kgs.) -60Hz • Cooling capacity of air cooled units based on 80°F ambient air temperature. Changes in air temperature will affect cooling capacity. • Unit specifications will change by adding certain options. * Also available in 50Hz Available Options c l i c k Similar Models (Click) Custom Design c l i c k Non - Refrigerated Models c l i c k R033 R050 R075 R100 R175 R250 R300 R400 R500 R550 R750 R1000 click for home page Model R400 100 Kelly Street, Elk Grove Village, IL 60007 Ph: 847-956-6420 Fax: 847-956-6595, info@haskris.com with air cooled condenser Cooling Capacity ( at 65°F supply water temp. ) Compressor HP Refrigerant Water Pump Capacity several alternatives available Pump Motor HP Reservoir Volume Power Requirements* Dimensions several alternatives available ( W x D x H ) in. Shipping Weight Refrigerated Water Recirculating Systems Watts Btu/Hr 12,500 42,625 with water cooled condenser Watts 13,500 Btu/Hr 46,025 4 4 R22 R22 7.9 GPM (30.0 LPM) 7.9 GPM (30.0 LPM) 3/4 3/4 30 Gallons (114 Liters) 30 Gallons (114 Liters) 208/230V-3 -60Hz 208/230V-3 -60Hz 47 x 36 x 56 30 x 36 x 48 900 Lbs. (408 Kgs.) 600 Lbs. (272 Kgs.) • Cooling capacity of air cooled units based on 80°F ambient air temperature. Changes in air temperature will affect cooling capacity. • Unit specifications will change by adding certain options. * Also available in 50Hz Available Options c l i c k Similar Models (Click) Custom Design c l i c k Non - Refrigerated Models c l i c k R033 R050 R075 R100 R175 R250 R300 R400 R500 R550 R750 R1000 click for home page Model R500 Refrigerated Water Recirculating Systems 100 Kelly Street, Elk Grove Village, IL 60007 Ph: 847-956-6420 Fax: 847-956-6595, info@haskris.com with air cooled condenser Cooling Capacity Watts Btu/Hr ( at 65°F supply water temp. ) Compressor HP several alternatives available 5 R22 R22 9 GPM (34.2 LPM) 9 GPM (34.2 LPM) 1 1 30 Gallons (114 Liters) 30 Gallons (114 Liters) Pump Motor HP Reservoir Volume Power Requirements* Dimensions several alternatives available ( W x D x H ) in. Shipping Weight Watts 17,000 Btu/Hr 57,975 15,500 52,850 5 Refrigerant Water Pump Capacity with water cooled condenser 208/230V-3 -60Hz or 460V-3 -60Hz 208/230V-3 -60Hz or 460V-3 47 x 36 x 56 30 x 36 x 48 900 Lbs. (408 Kgs.) 650 Lbs. (295Kgs.) -60Hz • Cooling capacity of air cooled units based on 80°F ambient air temperature. Changes in air temperature will affect cooling capacity. • Unit specifications will change by adding certain options. * Also available in 50Hz Available Options c l i c k Similar Models (Click) Custom Design c l i c k Non - Refrigerated Models c l i c k R033 R050 R075 R100 R175 R250 R300 R400 R500 R550 R750 R1000 click for home page Model R550 Refrigerated Water Recirculating Systems 100 Kelly Street, Elk Grove Village, IL 60007 Ph: 847-956-6420 Fax: 847-956-6595, info@haskris.com with air cooled condenser Cooling Capacity Watts Btu/Hr ( at 65°F supply water temp. ) with water cooled condenser Watts 19,500 Btu/Hr 66,500 18,000 61,375 Compressor HP 5.5 5.5 Refrigerant R22 R22 9 GPM (34.2 LPM) 9 GPM (34.2 LPM) 1 1 30 Gallons (114 Liters) 30 Gallons (114 Liters) Water Pump Capacity several alternatives available Pump Motor HP Reservoir Volume Power Requirements* Dimensions several alternatives available ( W x D x H ) in. Shipping Weight 208/230V-3 -60Hz or 460V-3 -60Hz 208/230V-3 -60Hz or 460V-3 47 x 36 x 56 30 x 36 x 48 900 Lbs. (408 Kgs.) 650 Lbs. (295 Kgs.) -60Hz • Cooling capacity of air cooled units based on 80°F ambient air temperature. Changes in air temperature will affect cooling capacity. • Unit specifications will change by adding certain options. * Also available in 50Hz Available Options c l i c k Similar Models (Click) Custom Design c l i c k Non - Refrigerated Models c l i c k R033 R050 R075 R100 R175 R250 R300 R400 R500 R550 R750 R1000 click for home page Model R750 Refrigerated Water Recirculating Systems 100 Kelly Street, Elk Grove Village, IL 60007 Ph: 847-956-6420 Fax: 847-956-6595, info@haskris.com with air cooled condenser Cooling Capacity Watts Btu/Hr ( at 65°F supply water temp. ) with water cooled condenser Watts 25,000 Btu/Hr 85,250 23,000 78,425 Compressor HP 7.5 7.5 Refrigerant R22 R22 12.5 GPM (47.5 LPM) 12.5 GPM (47.5 LPM) 1.5 1.5 30 Gallons (114 Liters) 30 Gallons (114 Liters) Water Pump Capacity several alternatives available Pump Motor HP Reservoir Volume Power Requirements* Dimensions several alternatives available ( W x D x H ) in. Shipping Weight 208/230V-3 -60Hz or 460V-3 -60Hz 208/230V-3 -60Hz or 460V-3 47 x 36 x 66 30 x 36 x 56 1000 Lbs. (454 Kgs.) 775 Lbs. (332 Kgs.) -60Hz • Cooling capacity of air cooled units based on 80°F ambient air temperature. Changes in air temperature will affect cooling capacity. • Unit specifications will change by adding certain options. * Also available in 50Hz Available Options c l i c k Similar Models (Click) Custom Design c l i c k Non - Refrigerated Models c l i c k R033 R050 R075 R100 R175 R250 R300 R400 R500 R550 R750 R1000 click for home page Model R1000 100 Kelly Street, Elk Grove Village, IL 60007 Refrigerated Water Recirculating Systems Ph: 847-956-6420 Fax: 847-956-6595, info@haskris.com with air cooled condenser with water cooled condenser Watts 30,000 Btu/Hr 102,300 Watts 33,000 Btu/Hr 112,530 Compressor HP 10 10 Refrigerant R22 R22 17 GPM (64.6 LPM) 17 GPM (64.6 LPM) 2 2 30 Gallons (114 Liters) 30 Gallons (114 Liters) Cooling Capacity ( at 65°F supply water temp. ) Water Pump Capacity several alternatives available Pump Motor HP Reservoir Volume Power Requirements* Dimensions several alternatives available ( W x D x H ) in. Shipping Weight 460V-3 -60Hz 460V-3 -60Hz 47 x 36 x 66 30 x 36 x 56 1200Lbs. (544 Kgs.) 900 Lbs. (408 Kgs.) • Cooling capacity of air cooled units based on 80°F ambient air temperature. Changes in air temperature will affect cooling capacity. • Unit specifications will change by adding certain options. * Also available in 50Hz Available Options c l i c k Similar Models (Click) Custom Design c l i c k Non - Refrigerated Models c l i c k R033 R050 R075 R100 R175 R250 R300 R400 R500 R550 R750 R1000 click for home page Non-Refrigerated Water Recirculating Systems ( Water-to-Water ) 100 Kelly Street, Elk Grove Village, IL 60007, Ph: 847-956-6420 Fax: 847-956-6595, info@haskris.com Model Cooling Capacity Details WW1 UpUp ToTo 6,000 Watts (20,460 Btu/Hr) Click Button For Tech Specs WW2 UpToTo Up 25,000 Watts (85,250 Btu/Hr) Click Button For Tech Specs WW3 Up Up To To 50,000 Watts (170,500 Btu/Hr) Click Button For Tech Specs WW4 Up To 150,000 Watts (511,500 Btu/Hr) Click Button For Tech Specs Available Options c l i c k Custom Design c l i c k Refrigerated Models c l i c k click for home page Non-Refrigerated Water Recirculating Systems Model WW1 100 Kelly Street, Elk Grove Village, IL 60007 12 Cooling Capacity Determined by temperature and flow of building water. See performance curve to the right. several alternatives available Pump Motor HP 1.7 GPM (6.4 LPM) 1/3 Reservoir Volume Power Requirements* 5 Gallons (19 Liters) several alternatives available ( W x D x H ) in. Shipping Weight 115-V-1 -60Hz 208/230V-1 dT= 10°F 10 Capacity (kW) Water Pump Capacity Dimensions Ph: 847-956-6420 Fax: 847-956-6595, info@haskris.com dT= 15°F dT= 20°F 8 dT= 25°F 6 4 -60Hz 2 19 x 26 x 25 175 Lbs. (79 Kgs.) 0 1 • Unit specifications will change by adding certain options. 2 3 4 Building Water Flow (GPM) * Also available in 50Hz dT= Temperature differential between the building water and the supply water to your equipment. BUILDING WATER = any source of cold water, including tap water or in-house chilled water. Custom Design Available Options c l i c k Similar Models (Click) Refrigerated Models c l i c k c l i c k WW1 WW2 WW3 WW4 click for home page Non-Refrigerated Water Recirculating Systems Model WW2 100 Kelly Street, Elk Grove Village, IL 60007 80 Cooling Capacity Determined by temperature and flow of building water. See performance curve to the right. several alternatives available Pump Motor HP dT= 15°F Power Requirements* 3.7 GPM (14.1 LPM) 14 Gallons (53 Liters) several alternatives available ( W x D x H ) in. Shipping Weight dT= 20°F 60 1/3 Reservoir Volume dT= 10°F 70 Capacity (kW) Water Pump Capacity Dimensions Ph: 847-956-6420 Fax: 847-956-6595, info@haskris.com 115-V-1 -60Hz 208/230V-1 -60Hz dT= 25°F 50 40 30 20 30 x 25 x 34 10 250 Lbs. (113 Kgs.) 0 2 3 • Unit specifications will change by adding certain options. 4 5 6 7 8 Building Water Flow (GPM) * Also available in 50Hz dT= Temperature differential between the building water and the supply water to your equipment. BUILDING WATER = any source of cold water, including tap water or in-house chilled water. Custom Design Available Options c l i c k Similar Models (Click) Refrigerated Models c l i c k c l i c k WW1 WW2 WW3 WW4 click for home page Non-Refrigerated Water Recirculating Systems Model WW3 100 Kelly Street, Elk Grove Village, IL 60007 Cooling Capacity Ph: 847-956-6420 Fax: 847-956-6595, info@haskris.com several alternatives available 140 Pump Motor HP 3/4 Reservoir Volume Power Requirements* 14 Gallons (53 Liters) several alternatives available ( W x D x H ) in. Shipping Weight dT= 10°F dT= 15°F 120 7.9 GPM (30.0 LPM) Capacity (kW) Water Pump Capacity Dimensions 160 Determined by temperature and flow of building water. See performance curve to the right. 115V or 208/230V-1 208/230V-3 -60Hz dT= 20°F dT= 25°F 100 -60Hz 80 60 40 30 x 25 x 34 20 300 Lbs. (136 Kgs.) 0 4 5 6 7 8 9 10 11 12 13 14 15 Building Water Flow (GPM) • Unit specifications will change by adding certain options. dT= Temperature differential between the building water and the supply water to your equipment. * Also available in 50Hz BUILDING WATER = any source of cold water, including tap water or in-house chilled water. Custom Design Available Options c l i c k Similar Models (Click) Refrigerated Models c l i c k c l i c k WW1 WW2 WW3 WW4 click for home page Non-Refrigerated Water Recirculating Systems Model WW4 100 Kelly Street, Elk Grove Village, IL 60007 180 Cooling Capacity Determined by temperature and flow of building water. See performance curve to the right. several alternatives available Pump Motor HP 160 17 GPM (64.6 LPM) 1.5 Reservoir Volume Power Requirements* 30 Gallons (113 Liters) several alternatives available ( W x D x H ) in. Shipping Weight dT= 10°F dT= 15°F 140 Capacity (kW) Water Pump Capacity Dimensions Ph: 847-956-6420 Fax: 847-956-6595, info@haskris.com 208/230V-1 -60Hz 208/230V-3 -60Hz dT= 20°F 120 dT= 25°F 100 80 60 40 31 x 36 x 34 20 400 Lbs. (181 Kgs.) 0 5 10 20 15 25 Building Water Flow (GPM) • Unit specifications will change by adding certain options. dT= Temperature differential between the building water and the supply water to your equipment. * Also available in 50Hz BUILDING WATER = any source of cold water, including tap water or in-house chilled water. Custom Design Available Options c l i c k Similar Models (Click) Refrigerated Models c l i c k c l i c k WW1 WW2 WW3 WW4 click for home page Optional Design Features Applies to all Haskris models Basic Design Options: To Refine or Enhance Performance: Option (G): Manual refrigerant hot gas bypass system for improved water temperature stability. Option (C): Water-cooled condenser with water saver control valve. For refrigerated units only. For refrigerated units cooling a steady heat load. See option(H). Option (D): Two separate water pumping systems. Option (H): Electronically controlled refrigerant hot gas bypass system for improved water temperature stability, to +/- 0.1 C or better . Option (R): Alternate Water Pump Option (Y): Multiple water circuits with flowmeters and metering valves, when cooling more than one piece of equipment from a single pump. For refrigerated units cooling a variable heat load. Also recommended for refrigerated units with air cooled condensers, when ambient air temperatures are variable and water temperature stability is critical. Option (O): Hand shut-off valves. Recommended with Option (Y). Option (I): For refrigerated units with air cooled condensers, when ambient air temperatures are excessively high. Option (J): For refrigerated units with air cooled condensers, when ambient air temperatures are excessively low. Option (H): Electronic close control for improved water temperature stability. For non-refrigerated, water-to-water (WW) units only. Convenience Options: Option (A): Flowmeter, to visually display flow of water through equipment. Option (M): Time clock, to operate the unit after normal working hours, up to 60 minutes. Option (P): Locking casters (in lieu of standard levelling legs). To Protect Your Equipment: Option (B): High temperature thermostat to de-energize pump motor on a rise in water temperature. Alternately, can be interlocked with your equipment. Option (N): Alarm system for high water temperature. Choice of “buzzer” only (single stage), or “buzzer” and pump cutout in sequence (two stage). Miscellaneous Options: Option (K): Used to designate any “non-standard” feature you would like built into your unit. Option (S): Flow switch to provide protection if water flow fails for any reason. Option (L): Supply water filter. Refrigerated Models c l i c k Click on the Custom Design button below Non - Refrigerated Models c l i c k 100 Kelly Street, Elk Grove Village, IL 60007, Ph: 847-956-6420 Fax: 847-956-6595, info@haskris.com Custom Design c l i c k click for home page 100 Kelly Street, Elk Grove Village, IL 60007 Ph: 847-956-6420 Fax: 847-956-6595 info@haskris.com Please call us to speak with one of our design engineers. e l p m a x e All Haskris systems are built to order. We specialize in custom designs. While we have a standard product line and many standard options, we rarely sell a standard system . Rather, we learn the application and customize the cooling system to the specific needs of the application. We strongly encourage our customers to "think outside the box" when developing the design spec. for the chiller because we have complete flexibility with our design. We can do things other chiller manufacturers are not set up to do. s Custom Design • Special materials of construction (stainless steel, PVC, food grade components, etc) • Low temp designs • High temp design • Custom dimensions to fit into a confined space • Piping manifolds for remote flow control • Multiple pumping systems • High pressure designs • Remote control panels • RS-232 communication • Custom alarms, safeties & interlocks • Flow rates from 0.1 GPM to 75.0 GPM • Custom designs for uncommon electrical service • Split refrigeration systems • Alternate refrigerants • Automatic reservoir refill • Automatic city water switchover • Water-to-air heat exchangers • Etc... We look forward to working with you to design a cooling system tailored to the special needs of your equipment or installation site.