DV Series

Transcription

DV Series
Operator’s Manual
DV SERIES
Gas Engine / Diesel Fired
READ
THIS
MANUAL
This manual contains important information for the use and safe operation
of your RAMTEQ machine. FAILURE TO READ THIS MANUAL AND
FOLLOW ITS INSTRUCTIONS PRIOR TO OPERATING OR ATTEMPTING
ANY SERVICE OR MAINTENANCE PROCEDURE COULD RESULT IN
SERIOUS INJURY OR DEATH TO YOU OR OTHER PERSONS; ALSO
DAMAGE TO THE MACHINE OR TO OTHER PROPERTY.
®
AMAZING MACHINERY
2288 Gunbarrel
Suite 111-151
RAMTEQ
14275 northwest
freeway Road,
 Houston,
TX
®
 Chattanooga,
37421  fax:
Phone:
1-800-504-7435 Fax: 1-800-504-7436
77040
 phone:TENNESSEE
713.983.6000
713.983.6405  300-00007-01
10/06
Operator’s Manual
Page Table of Contents
Section 1
Operator’s Manual
Unpacking....................................................................2
Safety Instructions and Warnings.............................3
 Maintenance Instructions...........................................4
 Operating Instructions...............................................6


Section 2 Parts









and
Service Manual
Parts List....................................................................7
Burner Assemblies......................................................8
Control Box Assembly................................................9
Hose, Wand, & Gun .....................................................9
Belt Driven Pump........................................................10
Wiring Diagram............................................................11
Plumbing Diagrams.......................................................13
Troubleshooting...........................................................14
Warranty.....................................................................15
Unpacking Instructions
INSPECTION
Carefully unpack your new RAMTEQ equipment by removing the shrink
wrap & banding from pallet. Remove the pressure washer from the
pallet and check for any physical damages that may have occurred
during shipment. Check for all parts specified and shown in figure 1. Included Parts
• Pallet
• Packing Material
Outer Box
• DV Series Machine
• Operator’s Manual
• Wand / Trigger Gun
• Nozzles 0º 15º 25º 40º
• Hose 3/8” X 50’
• QC Hose Fittings
NOTICE
Information in this operator’s manual is subject to change without notice. RAMTEQ SHALL NOT BE LIABLE FOR TECHNICAL OR EDITORIAL ERRORS OR OMISSIONS CONTAINED HEREIN. This operator’s manual
contains information protected by copyright. No part of this operator’s manual may be photocopied or reproduced in any form without
prior written consent from RAMTEQ.
© RAMTEQ, 2006
All rights reserved. Printed in USA.
RAMTEQ
®
14275 northwest freeway
 Houston, TX 77040

phone: 713.983.6000
 fax: 713.983.6405  300-00007-01
10/06
Operator’s Manual
Page Safety Guidelines
�
WARNING
READ THIS FIRST! Failure to read and observe all
WARNING statements could result in severe bodily injury or death, possible injury to other persons,
damage to machine or other property.
 DO NOT operate this machine in areas where open flames are not permitted. DO NOT store or
use combustible materials on or near this machine. Use this equipment only in well ventilated
areas. Failure to follow this warning may cause carbon monoxide build up, fire or explosion, and
possible injury or death.
 DO NOT fill gasoline tank while engine is running. Allow engine to cool before refueling. Should
gasoline be spilled, move the machine away from the area of the spill. Do not attempt to restart
the machine until the gasoline has fully evaporated.
 DO NOT operate engine if air cleaner or cover directly over the carburetor air intake is removed.
 DO NOT touch hot mufflers, cylinders or fins, as contact may cause burns
 DO NOT operate this machine while under the influence of alcohol, drugs or while fatigued.
 DO NOT direct discharge stream at yourself or others. Risk of injection or injury may occur.
Never put your hand or fingers over the spray tip. Do not try to stop or deflect leaks with your hand or body. Always face nozzle and wand to the ground when testing.
 DO NOT operate this machine without wearing protective Eye Wear. Gloves, Hard Hat, Mask, Ear Plugs & Steel Toe Work Boots are also recommended, DO NOT wear loose clothing. Keep
your body and clothing clear of the engine and discharge stream when the machine is running.
 DO NOT tie back or block trigger gun in OPEN position. Never leave the pressure washer
unattended once you have started it. If you leave, shut down machine completely.
 DO NOT overreach or stand on an unstable support while operating this machine. Maintain
good footing and balance.
 DO NOT permit this machine to run while unattended or for extended periods of time with
trigger gun closed. Damage to pump may occur.
 DO NOT operate this machine in an unsafe manner or around unsupervised children. Keep all
other personnel clear while operating this machine. This product should only be operated by
trained personnel.
 DO NOT alter original factory settings prior to operating this machine. Risk of injury to yourself or
other persons may occur.
 DO NOT remove hoses, guns, nozzles or any components while this machine is still hot or while
it is running.
 DO NOT attempt to service this machine before reading the service manual.
 DO NOT use water with a temperature over 140 degrees FareCHeit
 DO NOT put diesel fuel in to a gasoline tank or gasoline into a diesel tank. Observe correct
markings on fuel tanks before filling.
 DO NOT operate this machine without knowing how to stop and bleed water pressures. Know all
controls before using this machine.
 DO NOT spray caustic, acids or abrasive fluids through this machine.
 DO NOT permit water to freeze inside this machine. Pump and plumbing damage may occur.
 Use only recommended RAMTEQ™ parts when servicing this machine.
 RAMTEQ™ will not be held liable for any unauthorized modifications made to this
machine. Any such action will void the warranty.
 When connecting battery, ensure that the RED battery cable is connected to the POSITIVE pole
on the battery and the BLACK is connected to the NEGATIVE pole on the battery
RAMTEQ
®
14275 northwest freeway
 Houston, TX 77040

phone: 713.983.6000
 fax: 713.983.6405  300-00007-01
10/06
Operator’s Manual
Page Maintenance Instructions
MAINTENANCE PRECAUTIONS
 Do not permit acidic, caustic or abrasive fluids to be pumped through system.
 Periodically clean detergent inlet screen. This will ensure proper flow of water to the pump.
 High mineral content in water may adversely affect your machine and may require the use of a water softener
to ensure proper operation.
 NEVER run the pump dry under any circumtances. Doing so will cause exteme damage to the pump.
�
WARNING
FAILURE TO MAINTAIN HEAT EXCHANGER COIL MAY
RESULT IN A STEAM EXPLOSION WHICH MAY CAUSE
SERIOUS INJURY OR DEATH.
HEAT EXCHANGER COIL MAINTENANCE
 Hard water conditions may eventually cause clogging in the heat exchanger coil if left unattended. Scale deposits will compromise the heating efficiency and produce an unsafe condition over time. It may be necessary to descale coil.
 Scale buildup from certain detergents may eventually clog up the heat exchanger coil causing an
unsafe condition. Use only recommended detergents for better cleaning efficiency.  Black carbon deposits that collect on the outside wall of the heat exchanger coil may be a result of
using a poor grade of fuel or improper burner operation. Heating fuel should be void of water and
sediments to eliminate the possibility of sooting and compromising the efficiency of the coil.
MOVING, STORAGE
 Place machine in covered area when not in use to protect from elements.Protect machine from
freezing in cold temperatures by storing in a heated location.
ENGINE MAINTENANCE
 Every time (before start): Check oil level.
 First 8 hours: Change oil with SAE 30W High-Detergent Oil.
 Every 25 hours: Change oil if operating under heavy load or high ambient temperature.
Service air cleaner pre-cleaner.
 Every 50 hours: Change oil. Clean and inspect spark arrester if equipped.
 Every 100 hours: Service air cleaner cartridge, replace oil filter (if equipped),
Clean oil cooler (if equipped), Clean cooling system.
WINTERIZING
Non-float Tank Machines: To protect the machine from freezing temperatures while
storing or transporting, connect short length of garden hose (approximately 3 ft.) to
water inlet connection on machine. Remove the pressure nozzle from the wand and
insert the short garden hose end into a container of antifreeze. Place the wand into the
antifreeze container and start engine running machine until antifreeze appears from the
end of the wand. Turn engine “OFF” and replace pressure nozzle. Coil up hose and
move machine to storage area.

RAMTEQ
®
14275 northwest freeway
 Houston, TX 77040

phone: 713.983.6000
 fax: 713.983.6405  300-00007-01
10/06
Operator’s Manual
Page Maintenance Instructions
ELECTRODE SETTINGS
 Inspection of all wires, spring
contacts and electrodes should
be done periodically. �
WARNING
IF BLACK OR WHITE SMOKE VENTS FROM EXHAUST
PORT UPON STARTING EQUIPMENT, DISCONTINUE USE
AND ADJUST AIR BANDS BEFORE RESTARTING.
OIL BURNER AIR BAND ADJUSTMENT
RAMTEQ sets oil burners at sea level. Air bands may need adjustment at higher elevations to
offer eCHanced performance of the burner and extended life of the machine. ®
 Adjustment of burner is done with pump motor and thermostat
set to maximum. Loosen locking screw on air band, then close
band until black smoke vents up exhaust vent. Take careful note
of air band position when black smoke is first noticed. Slowly
open air band until white smoke vents, then turn air band halfway
back to where black smoke was first noted. Tighten air band
locking screw. When properly set, the unit should NOT have either
"black" smoke or "white" smoke during operation.
PUMP MAINTENANCE
 Fill crankcase to dot on oil gauge window per specifications with the specific oil created by the
pump manufacturer (i.e. General Pump Oil). Ensure the right oil for specific pump as it may vary.
 Change oil after 25 Hour Break-in Period.
 Change oil every Three Months or at 100 Hour Intervals thereafter.
UNLOADER ADJUSTMENT
 All RAMTEQ machines have the unloader correctly set at the the factory. Setting an unloader
is a difficult job without the proper equipment and training. Should the need arise to change the unloader
settings, please contact your local distributor.
RAMTEQ
®
14275 northwest freeway
 Houston, TX 77040

phone: 713.983.6000
 fax: 713.983.6405  300-00007-01
10/06
Operator’s Manual
Page Operating Instructions
LOCATION GUIDELINES
 Locate the machine on a solid and level surface so that engine and pump crankcase oil lubricate components properly.
Avoid areas where water can build up in the working area. Possible injury can occur caused by the surface becoming
slippery from water build up.
 Locate the machine in a well-ventilated area and away from flammable materials or fumes. Be sure ventilation warnings
are observed. Keep pressure washer at least 18” away from flamable materials.
 Locate the machine so the operator has easy access to the jetter/pressure washer and its controls. Locate the machine
so that it is protected from external damage.
 To prevent damage and excessive hose wear, locate the unit so that the hose does not cross traffic areas.
STARTING THE MACHINE
Following the steps below will insure successful operation:
 Read this manual completely before attempting to start the machine.
 Check the fuel tank and fill with a good grade of gasoline (87 octane minimum) for gas engines and a high quality diesel
fuel for diesel engines.
 Check the engine oil level and fill with SAE 30 weight high-detergent oil.
 Check the pump oil level and fill with SAE 30w non-detergent oil if needed.
 Check water tank to ensure adequate level of water required for the job.
 Pull trigger on gun until a steady stream of water comes out the nozzle. This purges any air in the system.
 Slide fuel switch to the RIGHT and slide choke switch to the LEFT (closed position).
 Turn ON/OFF switch (on engine) to “ON”.
 Open water flow to reduce back pressure in pump. Back pressure can overpower electric starter, preventing ignition.
 Turn key to start gas engine and allow RPM to develop.
 Let engine warm up for approximately 30 seconds and slide choke to “OPEN” position.
 Check for leaks in the system and cycle trigger gun to insure bypass is adjusted correctly. Repair any leaks and correct unloader adjustment if needed. Turn off machine before attempting any repairs.
 WARNING - Do not operate machine with less than 6" of water in the tank. Doing so may cause pump damage!
STOPPING THE MACHINE
 Turn engine to “OFF”.
 Pull gun trigger to release water pressure from system.
 Disconnect wand & gun assembly.
 Wind up pressure hose on hose reel.
CAUTION
 Always wear protective safety gear, auch as, but not limited to, rain coat or coveralls, rubber boots, face shield or
goggles, gloves and hearing protection.
 Do not run the machine for more than two minutes with the jetter water flow shut off (by-pass mode). This will over
heat the jetter pump and could cause injury to you.
 Do not run hot water thru this pump. Hot water will damage the pump, and will void the warranty.
RAMTEQ
®
14275 northwest freeway
 Houston, TX 77040

phone: 713.983.6000
 fax: 713.983.6405  300-00007-01
10/06
Operator’s Manual
Page 13
14
12
DV Parts List
16
11
9
Exploded
view on
page 9.
15
17
10
8
7
18
6
19
5
4
20
3
21
2
1
Ref.#
Part # Description 1 2 3 4
5 6 7 8 9 10
11
12
13
14
15
16
17
18
19
20
21
22
190-00001-01 140-00002-01 190-00001-02 140-00001-01 519-00001-01 180-00076-01 579-00006-01 180-00139-01 180-00280-01 206-00006-01 206-00007-01 206-00011-01 206-00013-01 216-00001-01 220-00010-01 220-00008-01 220-00014-01 590-00001-01 439-00003-06 439-00003-05 180-00104-01 191-00004-01 180-00072-01 180-00020-01 191-00006-01 155-00006-01 180-00115-01
250-00007-01 250-00005-01
055-00041-01 569-00002-01 180-00116-01 180-00013-02 180-00137-01 180-00138-01 180-00172-01 180-00048-01 180-00051-01 584-00002-52 584-00002-47 584-00002-46 584-00003-31 516-00003-21 516-00002-21 586-00004-04 586-00004-02 586-00004-05 586-00004-01 Tank, Fuel 10gal Green Cap, Fuel Gauge Gas Red Tank, Fuel 10gal Red Cap, Fuel Gauge Diesel Black Spacer, Rubber Skid
Bracket, Metering Valve Metering Valve Plate, Power, DV Series Plate, Power, DV Diesel Series Engine, 16hp B&S Vanguard 303447-1075-A1 Engine, 20hp B&S Vanguard 351447-1046-A1 Engine, 25hp Kohler CH25S,PA-68591 Engine,Diesel,19hp,Ruggerini MD191 Generator, Voltmaster AB-25 Pump, General TS2021 (DV1600 4.8@3000/DV2000@3500/DV1901-02)
Pump, General T9281-L (DV1600 4@4000) Pump, General T5050-L (DV2500 5@4000/DV1901-04) Box, Battery Cable, Battery Black (not shown) Cable, Battery Red (not shown) Shell, SS Stationary 18” Insulation, Cap Cap, Coil, Large 10” Center Shell, SS Removable 18” x 23” Insulation, Blanket, 1” x 24”w #4 Coil, Diesel Vertical Plate, Burner DV Series Burner Assembly Wayne EH-V-115 (w/generator) Burner Assembly Wayne MSR-H-12 (12 volt, not shown) Float Tank Assembly Float Valve Fluidmaster Frame, DV Series Strap Fuel Tanks Bracket, Belt Guard Skid Plate, Pump Guard Skid Generator, Guard Bracket, Pump, Belt Tension Bracket, Pump, Belt Stationary Pulley, 2MBL87 (DV1600, DV1900, DV2000 - 4.8@3000) Pulley, 2MBL67 (DV1600 4@4000) Pulley, 2MBL64 (DV2500, DV1900 - 5@4000) Pulley, Motor, 3B34 Bushing, SP Split Taper, SH-1 Bushing, SP Split Taper, L-24mm Belt, BX36 (DV1600, DV1900, DV2000 - 4.8@3000) Belt, BX34 (DV1600 4@4000) Belt, BX32 (DV2500, DV1900 - 5@4000) Belt, Generator BX22 RAMTEQ
®
14275 northwest freeway
 Houston, TX 77040

22
phone: 713.983.6000
Qty.
1
1
1
1
7
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
8
1
1
1
2
2
1
1
1
1
1
1
2
2
2
1
 fax: 713.983.6405  300-00007-01
10/06
Operator’s Manual
Page 5
4
6
7
8
3
9
DV 12v Burner Assembly
2
1
11
10
Ref#
1
2
3
3a
4
5
6
7
8
9
Part #
Description
Qty
256-00001-02Main Burner Gasket
253-00002-01Fan Wheel 3.44” x 4.25”
254-00001-04Motor, 12v DC
Motor, Flange
252-00001-04Ignitor
253-00001-01Coupling
251-00001-01Fuel Pump Suntec
245-00006-16Fuel Nozzle 2.25 80º
258-00002-03Electrodes
577-00003-01Filter, Fuel Inline Racor
578-00001-01Element, Fuel Filter, Racor
1
1
1
1
1
1
1
1
1pr
1
1
Burner Assembly Complete
250-00006-01MSR-H-12 Wayne 12 Volt Burner
3 4
5
2
8
7
1a
6
1
9
DV 115v Burner Assembly
Ref.# Part #
Description
1a-1
1a-2
2
3
3b
3c
4
5
5a
6
7
8
8a
9
10
11
Fuel Pump Solenoid (NLH150,NLH200, NLH230)
1
Fuel Pump Solenoid (NLH300, NLH500) 1
Main Burner Gasket 1
Nozzle, Fuel 1.35/125psi (NLH150, NLH200, NLH230) 1
Nozzle, Fuel 1.65/140psi (NLH300)
1
Nozzle, Fuel 1.50/125psi (NLH500)
1
Electrode Pair (RH & LH)
1
Transformer 115v (NLH150, NLH200, NLH230) 1
Transformer 230v (NLH300, NLH500) 1
Coupling 1
Fan Wheel 3.44" X 4.25" 1
Motor 115v/60/1 (NLH150, NLH200, NLH230) 1
Motor 208/230v/60/1 (NLH300, NLH500)
1
Filter, Fuel Inline 1
Clamp, Hose
2
Hose, Inlet/Outlet Fuel Line
1
252-00002-01
252-00002-01
256-00001-01
245-00006-11
245-00006-12
245-00006-12
258-00002-01
252-00001-06
252-00001-07
253-00001-01
253-00002-01
254-00001-01
254-00001-02
577-00002-01
557-00001-01
280-00003-01
Burner Assembly Complete
250-00001-01 250-00008-01 RAMTEQ
®
14275 northwest freeway
Wayne Burner Vertical 115v
Wayne Burner Vertical 230v
 Houston, TX 77040

phone: 713.983.6000
Qty
1
1
 fax: 713.983.6405  300-00007-01
10/06
Operator’s Manual
Page DV Control Box Assembly
Ref.# Part #
1
2
3
4
5
6
7
Description
180-00027-01 305-00006-01 450-00001-01 573-00001-01 505-00001-01 508-00002-01 180-00150-01 Qty
Control Box Panel
Label, Control Box Small
Pump/Burner Switch On/Off Thermostat Assembly 1/4" X 20 Thumb Screw
Tinnerman
Control Box
1
1
1
1
2
2
1
Qty
1
Hose, Wand & Gun
7
4
3
5
2
6
10
8
9
Ref#
Part#
Discription
1.
1a.
1b.
1c.
1d
1e.
1f.
1g.
1h.
1f.
1g.
1h.
2.
3.
4.
5.
6.
6a.
7.
8.
9.
10.
270-00005-01
270-00005-02
270-00005-03
270-00005-04
270-00004-01
270-00004-02
270-00004-03
270-00004-04
270-00002-01
270-00002-02
270-00002-03
270-00002-04
554-00006-02
265-00002-01
275-00001-01
552-00004-03
284-00001-01
284-00002-01
270-00038-01
552-00003-03
554-00007-03
020-00005-01
Nozzle, Water, #5.5, 0° Quick Connect (16-21 HP)
Nozzle, Water, #5.5, 15° Quick Connect (16-21 HP)
Nozzle, Water, #5.5, 25° Quick Connect (16-21 HP)
Nozzle, Water, #5.5, 40° Quick Connect (16-21 HP)
Nozzle, Water, #5.0, 0° Quick Connect (20-25 HP)
Nozzle, Water, #5.0, 15° Quick Connect (20-25 HP)
Nozzle, Water, #5.0, 25° Quick Connect (20-25 HP)
Nozzle, Water, #5.0, 40° Quick Connect (20-25 HP)
Nozzle, Water, #4.0, 0° Quick Connect (10 HP)
Nozzle, Water, #4.0, 15° Quick Connect (10 HP)
Nozzle, Water, #4.0, 25° Quick Connect (10 HP)
Nozzle, Water, #4.0, 40° Quick Connect (10 HP)
Quick Coupler Socket, 1/4” Male
Dual Wand, Insulated
Gun
Quick Coupler Plug, 3/8”
Hose Assembly, 50’, 3000PSI @ 250°F (10-16 HP)
Hose Assembly, 50’, 5000PSI @ 250°F (18-25 HP)
Nozzle, Soap
Quick Coupler Plug, 3/8 nptm (not shown)
Quick Coupler Socket, 3/8 nptf (not shown)
Downstream Injector Kit (hose not shown)
RAMTEQ
®
14275 northwest freeway
 Houston, TX 77040

phone: 713.983.6000
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
 fax: 713.983.6405  300-00007-01
10/06
Operator’s Manual
Page 10
1
DV Belt Drive Pumps
2
General Pump TS2021-R Triplex Plunger Pump
Pump Repair Parts
Ref#
1.
2.
Part#
220-00009-01
221-00001-03
Pump Repair Kits (not shown)
221-00021-01
221-00020-01
221-00019-01
221-00023-01
221-00031-01
Description
Pump, Complete, General TS2021-R
Manifold, Brass Head TS2021
Qty
1
1
Check Valve Assembly Kit #1 (6 Each)
(3 Oil Seals)
Oil Seals, Kit #2 (6 Each)
Valve Cap and O-Ring, Kit #16
(3 Each)
V-Packing, Kit #69 Piston/Plunger, 20MM
1
1
1
1
3
General Pump TS1511 & T9211Triplex Plunger Pump
Pump Repair Parts
Ref#
1a.
1b.
2a.
2b.
Part#
220-00053-01
220-00103-01
contact ramteq
contact ramteq
Pump Repair Kits (not shown)
221-00002-01
221-00018-01
221-00072-01
221-00081-01
221-00029-01
221-00031-01
Description
Pump, Complete, General TS1511
Pump, Complete, General T9211
Manifold, Brass Head TS1511
Manifold, Brass Head T9211
Qty
1
1
1
1
Check Valve Assembly Kit #1 (6 Each)
(3 Oil Seals)
Oil Seals, Kit #2 O-Ring for Valve Cap Kit
(6 Each)
Brass Valve Cap Kit (6 Each)
(3 Each)
V-Packing, Kit #69 Piston/Plunger, 20MM
1
1
1
1
1
3
General Pump T9821 Triplex Plunger Pump
Pump Repair Parts
Ref#
1.
2.
Part#
220-00008-01
contact ramteq
Pump Repair Kits (not shown)
221-00002-01
221-00018-01
221-00025-01
221-00029-01
221-00044-01
Description
Pump, Complete, General T9821
Manifold, Brass Head T9821
Qty
1
1
Check Valve Assembly Kit #1 (6 Each)
(3 Oil Seals)
Oil Seals, Kit #2 (6 Each)
Valve Cap and O-Ring, Kit #6
(3 Each)
V-Packing, Kit #69 Piston/Plunger, 20MM
1
1
1
1
3
1
2
Comet SW5540 Triplex Plunger Pump
Pump Repair Parts
Ref#
1.
2.
Part#
220-00099-01
contact ramteq
Pump Repair Kits (not shown)
RAMTEQ
®
221-00021-01
221-00020-01
221-00023-01
14275 northwest freeway
Description
Pump, Complete, Comet SW5540
Manifold, Brass Head SW5540
Qty
1
1
Check Valve Kit (6 Each)
Complete Oil Seals, O-Ring Kit
Packing Kit
(3 Each)
1
1
1
 Houston, TX 77040

phone: 713.983.6000
 fax: 713.983.6405  300-00007-01
10/06
Operator’s Manual
Page 11
DV Wiring Diagram
BURNER
MODULE
“Small” BLK
RED
WHT
BLK
BLOWER
“Big” RED
IGNITOR XFMR
yellow
- N.O.
+
yellow
White
BLK
Orange
FUEL SOLENOID
DROPOUT
TIMER
yellow
Photocell
“Small” RED
BLK
RED
WHT
BLK
CONTROL PANEL
RED
AC
+
BURNER SW
WHT
-
AC
RED
BLK
RED
BLK
WHT
TYPICAL
SCHEMATIC
BLK
87
WHT
86
85
1
30
P1
THERMOSTAT
RED
RED
BRN
RED
RED
GRN
WHT
BLK
FLOW SW or
PRESSURE SW
STARTER
SOLENOID
BATTERY
BLK
ALTERNATOR
12 VOLT
Electrical
Schematic
RAMTEQ
®
GAS ENGINE
1 4 2 75 NW FRE E WAY P H O N E : 71 3 . 9 8 3 . 6 0 0 0
14275 northwest freeway
 Houston, TX 77040

phone: 713.983.6000
H O U S T O N, TX 77 0 4 0 FA X: 71 3 . 9 8 3 . 6 4 05
 fax: 713.983.6405  300-00007-01
D
6/02/06
new wiring diagram
bbp
C
4/21/06
simplify diagram
bbp
10/06
wiring 12v gas engines
PROJECT:
all 12v gas
DRAWING NUMBER:
REV:
Operator’s Manual
Page 12
DV Wiring Diagram
ELECTRICAL SCHEMATIC
DV w/ GENERATOR
WHT
BLK Burner
Mtr
BLK
Burner
Module
GRN
BLK
Transformer
for Ignitor
ORG
3
WHT
INDICATES FINAL ASSY TASK
Grn
A
Wht
INDICATES CONTROL BOX KANBAN
Blk
A
Red
Fuel
Solenoid
A INDICATES POWER PLATE KANBAN
A
INDICATES ASSEMBLED FROM OTHER AREAS
BURNER CABLE
16/4 X 60"
STRIP 7" EACH END
6
HOURMETER
GRN
BLK
WHT
WHT
BLK
BLK
RED
BLK
WHT
BURNER
SWITCH
RED
1
P
5
4
THERMOSTAT
N.C.
7
BRN
RED
BRN
RED
1
WHT
GRN
SMOOTH
WIRE=
BLK
RIBBED
WIRE=WHT
POWER CORD
LENGTH =49"
STRIP 10"
PRESSURE SWITCH CORD
LENGTH = 26"
STRIP JACKET BACK 10"
PRESSURE SWITCH
574-00002-01
11/10/98
115v rt angle plug
RAMTEQ
®
14275 northwest freeway
 Houston, TX 77040

phone: 713.983.6000
 fax: 713.983.6405  300-00007-01
10/06
Operator’s Manual
Page 13
DV Pump Plumbing
MODELS: DV BASE
RELIEF VALVE
JE ADAMS 7468 (3500 PSI)
569-00003-05
HIGH PRESSURE HOSE
3/8 I.D. X 15"
280-00001-02
HOSE END, HIGH PRESSURE (2 PL.)
3/8 NPTM SWIVEL X 3/8 HOSE
282-00001-01
A
ELBOW, PLATED STEEL
3/8 STREET
528-00006-01
1/4 NPT PLUG
518-00001-01
BUSHING, SP
3/8 NPTM X 1/4 NPTF
517-00002-01
FROM COIL OUTLET
HOSE END, SWIVEL
#8 JIC FEMALE X 3/8 BARB
281-00002-01
3/8 NPT PLUG
518-00004-01
ELBOW, PLATED STEEL
3/8 NPTM X 3/8 NPTM
528-00002-01
UNLOADER
SUTTNER ST-280
230-00004-01
PRESSURE
SWITCH
574-00002-01
MANIFOLD
THERMOSTAT 194°
573-00001-01
ELBOW, BRASS
#8 FLARE X 1/4 NPTM
530-00002-01
PUMP
HOSE END, SWIVEL
#8 JIC FEMALE X 1/2 BARB
BUSHING, BRASS
1/2 NPTM X 3/8 NPTF
NIPPLE, GALV. STEEL
1/2 NPT X 2.5"
526-00005-01
QUICK CONNECT COUPLER
3/8 NPTM X 3/8 SOCKET
554-00006-03
HOSE END, SWIVEL
#8 JIC FEMALE X 3/8 BARB
LOW PRESSURE HOSE
3/8 I.D. X 13"
280-00002-02
A
SECTION AA
TEE, STREET, BRASS
3/8 NPTM X #8 FLARE
538-00008-01
TO COIL INLET
CONNECTOR, BRASS
#8 FLARE X 1/2 NPTM
554-00005-01
LOW PRESSURE HOSE
3/8 I.D. X 36"
280-00002-02
GARDEN HOSE CONNECTOR
3/4 SWIVEL X 1/2 NPTM
542-00001-01
ELBOW, PLATED STEEL
3/8 NPTF X 1/2 NPTF
528-00007-01
NIPPLE, GALVANIZED STEEL
1/2 NPT X 2.5"
526-00005-01
HOSE END, SWIVEL
#8 JIC FEMALE X 3/8 BARB
281-00002-01
COUPLER, FRAME MOUNTED
1/2 NPTF X 1/2 NPTF
MODELS: DV UPGRADE
ELBOW, BRASS (2 PL.)
1/4 NPTM X 1/4 BARB
530-00002-02
DETERGENT LINE
1/4" I.D. TUBE X 50"
285-00002-01
METERING VALVE
579-00006-01
LOW PRESSURE HOSE
1/4" I.D. X 15", BLACK
280-00002-01
HOSE END, HIGH PRESSURE (2 PL.)
3/8 NPTM SWIVEL X 3/8 HOSE
282-00001-01
A
ELBOW, PLATED STEEL
3/8 STREET
528-00006-01
FROM COIL OUTLET
HOSE END, SWIVEL
#8 JIC FEMALE X 3/8 BARB
281-00002-01
3/8 NPT PLUG
518-00004-01
ELBOW, PLATED STEEL
3/8 NPTM X 3/8 NPTM
528-00002-01
UNLOADER
PULSAR 3HP
230-00011-02
PRESSURE
SWITCH
574-00002-01
PUMP
BUSHING, BRASS
1/2 NPTM X 3/8 NPTF
HOSE END, SWIVEL
#4 JIC FEMALE X 1/4 BARB
281-00001-01
LOW PRESSURE HOSE
3/8 I.D. X 13"
280-00002-02
SECTION AA
TO COIL INLET
ELBOW, PLATED STEEL
3/8 NPTF X 1/2 NPTF
528-00007-01
FLOAT TANK
LOW PRESSURE HOSE
1/2 I.D. X 31"
CONNECTOR, BRASS
#8 FLARE X 1/2 NPTM
554-00005-01
GARDEN HOSE CONNECTOR
3/4 SWIVEL X 1/2 NPTM
542-00001-01
BULKHEAD FITTING
1/2 NPTF I.D.
518-00002-01
TEE, POLYPROPYLENE
3/8 BARB X 3/8 BARB X 3/8 BARB
539-00002-01
ELBOW, POLYPROPYLENE
3/8 BARB X 3/8 BARB
531-00002-01
CLAMP BAND
Ø1/4 - 5/8 (6 PL.)
557-00001-01
COUPLER, FRAME MOUNTED
1/2 NPTF X 1/2 NPTF
®
NIPPLE, GALVANIZED STEEL
1/2 NPT X 2.5"
526-00005-01
FLOAT VALVE (2 PL.)
569-00002-01
LOW PRESSURE HOSE
3/8 I.D. X 36"
280-00002-02
HOSE END, SWIVEL
#8 JIC FEMALE X 3/8 BARB
281-00002-01
RAMTEQ
THERMOSTAT 194°
573-00001-01
HOSE END, SWIVEL
#8 JIC FEMALE X 3/8 BARB
A
TEE, STREET, BRASS
3/8 NPTM X #8 FLARE
538-00008-01
MANIFOLD
ELBOW, BRASS
#8 FLARE X 1/4 NPTM
530-00002-01
HOSE END, SWIVEL
#8 JIC FEMALE X 1/2 BARB
ELBOW, BRASS
1/2 NPTM X #4 FLARE
530-00004-05
NIPPLE, GALV. STEEL
1/2 NPT X 2.5"
526-00005-01
QUICK CONNECT COUPLER
3/8 NPTM X 3/8 MALE
552-00002-01
1/4 NPT PLUG
518-00001-01
BUSHING, SP
3/8 NPTM X 1/4 NPTF
517-00002-01
RELIEF VALVE
JE ADAMS 7468 (3500 PSI)
569-00003-05
HIGH PRESSURE HOSE
3/8 I.D. X 15"
280-00001-02
14275 northwest freeway
GATE VALVE
CLAMP BAND
Ø0.4 - 0.9
557-00001-02
 Houston, TX 77040

phone: 713.983.6000
ELBOW, BRASS
1/2 NPTM X 1/2 NPTM
CONNECTOR, BRASS
1/2 NPTM X 1/2 BARB
 fax: 713.983.6405  300-00007-01
10/06
Operator’s Manual
Page 14
troubleshooting
problem
Low Water Pressure
cause
action
Insufficient water source
Old or incorrect nozzle
Plumbing or hose leak
Obstruction in spray nozzle
Chemical valve open
Unloader valve worn
Pump valves dir ty or worn
Check hose size/water source
Replace nozzle
Tighten, repair or replace leak
Clean or replace nozzle
Close valve or submerge hose
Replace unloader
Clean or replace packing/valves
Detergent valve closed
Low detergent level
Chemical screen dir ty
Open detergent valve
Fill detergent container
Clean detergent screen
Fill fuel tank with proper fuel
Turn burner switch on
Reset thermostat
Replace fuel filter
Replace pressure switch
Replace burner nozzle
Replace fuel pump
Clean/reset to specifications
No Chemical Flow Burner Not Igniting
No fuel Burner switch turned off
Thermostat set too low
Clogged fuel filter Defective pressure switch
Clogged burner nozzle
Fuel pump malfunction
Improper electrode setting
Excessive Burner Smoke
Improper fuel being used
Water contamination in fuel Improper air band adjustment
Low fuel pressure Air leaks in fuel lines
Soot on coils/burner assembly
Misaligned electrodes
Dir ty burner nozzle
Use Diesel #1/#2 or Kerosene
Drain fuel and replace with new
Readjust air band/altitude
Adjust to specifications
Check for air leaks or bubbles
Clean coils/burner assembly
Realign to specifications
Clean or replace burner nozzle
Relief Valve Leaks Nozzle is dir ty
Defective relief valve
Unloader adjusted incorrectly
Restriction on discharge hose
Scale restricting flow in coil Clean or replace nozzle
Replace relief valve
Adjust unloader valve
Remove nozzle and flush line
Clean coil
Pressure
Engine Will Not Star t
Throttle lever off No fuel in engine Bad fuel or wrong fuel in engine
Worn, foul, or dir ty spark plug(s)
Pressure bulid up in pump Turn throttle lever to "on" position
Fill fuel tank if needed
Check to ensure correct fuel in tank
Check spark plugs
Squeeze trigger on gun
Engine runs rough/no power
Low oil level
Dir ty air filter
Bad fuel or wrong fuel in engine
Worn, foul, or dir ty spark plug(s)
Overchoking
Engine has lost compression
Intake valve stuck open or stuck closed
Incorrect fuel/air mixture
Check oil level, fill if needed
Check and replace air filter if needed
Check to ensure correct fuel in tank
Check spark plugs
Open choke fully and crank engine
Service engine at repair center
Service engine at repair center
Service engine at repair center
Pump Noisy
Air in suction line Pump valves dir ty Check valve springs worn
Low pump oil Pump bearings are worn
Incoming water too hot
Check inlet water fittings
Clean/replace pump valves
Replace check valves
Add SEA 30wt. non-detergent
Replace/rebuild pump
Reduce temperature/ambient
Water In Oil
High humidity environment Oil seal worn Plunger packing worn
Change oil frequently
Check and replace oil seal
Check and replace packing
Water Dripping/Pump
Plunger packing is worn
Plunger retainer oil ring worn Cracked ceramics Install new packing kit
Replace oil ring
Replace ceramics
Oil Dripping
Oil seal worn
Cracked manifold Check and replace oil seals
Replace manifold
Unloader not adjusted
Valves worn
Dir t or blockage in valves
Pump sucking air Worn plunger packing
Fluctuating Pressure
Pump Head Overheating RAMTEQ
®
14275 northwest freeway
Extended period in bypass  Houston, TX 77040

Adjust to specifications
Replace with valve kit
Clean or replace valve
Check water/detergent supply
Replace packing kit
Pull trigger gun for water flow
phone: 713.983.6000
 fax: 713.983.6405  300-00007-01
10/06
RAMTEQ
Limited One Year
WARRANTY
Ramteq Incorporated ("RAMTEQ") warrants that the Product you have purchased from RAMTEQ or from an
Authorized RAMTEQ Reseller is free from defects in materials or workmanship under normal use for a period of one
(1) year from the date of purchase. This warranty extends only to you, the original Purchaser. It is not transferable to anyone who subsequently purchases the Products from you. This warranty specifically excludes expendable
items, including but not limited to hoses, seals, nozzles and gunjets. RAMTEQ manufacturers warrant certain components of the Products for periods greater than one (1) year. MOTORS, GENERATORS, PUMPS, COILS, BURNERS
AND ENGINES ARE WARRANTED BY THEIR RESPECTIVE MANUFACTURERS, AND SERVICED THROUGH THESE
MANUFACTURERS' LOCAL AUTHORIZED SERVICE CENTERS. Specific warranty details can be found on the individual manufacturers website. RAMTEQ CANNOT PROVIDE WARRANTY ON THESE ITEMS.
During the warranty period, RAMTEQ will repair or replace defective parts, at the option of RAMTEQ.
This limited warranty does not extend to any Product not purchased from RAMTEQ or from an Authorized RAMTEQ
Reseller. This limited warranty also does not extend to any Product that has been damaged or rendered defective (a)
as a result of accident, misuse or abuse; (b) by operation outside the specifications in the intended applications; (c) by
the use of parts not sold or manufactured by RAMTEQ; (d) by the modification of the Product.
Warranty Disclaimer
EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY, RAMTEQ MAKES NO OTHER WARRANTIES, EXPRESS
OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE. RAMTEQ EXPRESSLY DISCLAIMS ALL AND ANY WARRANTIES NOT STATED IN THIS LIMITED
WARRANTY. ANY IMPLIED WARRANTIES THAT MAY HAVE BEEN IMPOSED BY LAW ARE LIMITED TO THE TERMS
OF THIS EXPRESS LIMITED WARRANTY.
Limitation of Remedy
RAMTEQ IS NOT LIABLE FOR ANY DAMAGES CAUSED BY THE PRODUCT OR FAILURE OF THE PRODUCT TO
PERFORM, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. THIS LIMITATION APPLIES WHETHER
DAMAGES ARE SOUGHT, OR A CLAIM MADE, AS A CONTRACT CLAIM, AS A TORT CLAIM, OR ANY OTHER
CLAIM.
THIS LIMITATION OF LIABILITY, HOWEVER, WILL NOT APPLY FOR PERSONAL INJURY.
U.S.A. State Laws
Some states do not allow limitation on how long an implied warranty lasts. In such states, the limitations or
exclusions of this Limited Warranty may not apply to you.
Some states do not allow the exclusion or limitation in incidental or consequential damages for consumer products. In
such states, the exclusion may not apply to you. This limited warranty gives you specific legal rights. You may also
have other rights that may vary from state to state. You are advised to consult applicable state laws for a full
determination of your rights.
How to Obtain Warranty Service
TO OBTAIN WARRANTY SERVICE YOU MUST CONTACT RAMTEQ or an AUTHORIZED RAMTEQ RESELLER.
RAMTEQ
®
14275 NORTHWEST FREEWAY
 HOUSTON, TX 77040

PHONE: 713.983.6000
 FAX: 713.983.6405
 300-00001-01
1/13
Ramteq
Manufacturers Warranty Period
Click on pictures to open manufacturers website.
5 years
5 years
3 years
3 years
3 years
3 years
18 months
18/36 months
Ramteq Pressure Washers
14275 NORTHWEST FREEWAY
HOUSTON, TX 77040
1 year
PHONE: 713.983.6000
FAX: 713.983.6405
1/13