Spheric or aspheric IOL? - Visual Optics Institute
Transcription
Spheric or aspheric IOL? - Visual Optics Institute
Augenklinik Klinikum Rechts der Isar Technische Universität München Direktor Prof. Dr. Dr. C-P Lohmann Spheric or aspheric IOL? A Lindenschmid1, M Küchle2, U Schönherr3, C Lohmann1, C Winkler v Mohrenfels1 1 Technical University Munich 2 Eye Research Center, Erlangen 3 Kantonspital Barmherzige Brüder, Linz No financial Interest Aberratios and Cataract surgery cornea lens + total = spheric / aspheric IOL Perception with standard IOL Perception with optimal IOL Setting • 3 centers (Munich, Erlangen, Linz) • • • • • 30 patients First eye: aspheric IOL (HumanOptics MX 611ASP) second eye spheric IOL (HumanOptics MC 611MI) Visual acuity Contrast Sensitivity – Pelli Robson – Optec 6500 • Topography • Wavefront (Tracey 2.0, Ray Tracing) Patients Inclusion/exclusion criteria • Bilateral catarat • No other eye pathology (e.g. PEX, Maculopathy, Uveitis) • No previous eye surgery MC X11 ASP Foldable one-piece posterior chamber lens Optical diameter: 5,5 mm - 7,0 mm Total diameter: 11,0 mm Angulation: 0° 5,5 –7,0 mm MC 611 MI Foldable one-piece micro-incision posterior chamber lens Optical diameter: 6,0 mm Total diameter: 11,0 mm Angulation: 0° 6,0 mm 11 mm Injector: Mini Glide 1,8mm Est. A-constancy: 118.3 (Haigis) 11 mm Injector: Mini Glide 1,8mm Est. A-constancy: 118.3 (Haigis) Patients N=30 age ASP MI 72,67 (± 7,87) Preop SE - 0,5 (±2,25) -0,83 (±2,38) Lens power 22,16 (±2,45) 21,89 (± 2,53) Axial lens 23,39 (± 0,75) 23,55 (± 0,66) Results N=30 ASP MI postop SE (3m) -0,18 (± 0,33) -0,39 (±0,29) BCVA 0,87 (± 1,8) 0,83 (± 1,9) pupil 4,65 (± 0,58) 4,69 (± 0,63) Pelli Robson 10.7 (± 1,2) 9,9 (± 1,4) Visual acuity - 3 mo bcva % of eyes 100 90 80 70 60 50 MI 40 ASP 30 20 30 85 35 85 10 0 20/16,5 20/20 90 95 20/25 100 100 20/30 100 100 20/40 Results 10.7 (± 1,2) ASP 9,9 (± 1,4) MI Results • Spherical Aberration spherical aberration [µm] median 0.5 aspheric spheric 0.4 0.3 0.2 0.1 0 2 3 4 5 pupil diameter [mm] 6 7 Results • Optical aberrations, e.g. 77 y/o male median 0.4 aspheric spheric spherical aberrations [µm] 0.3 0.2 0.1 0 -0.1 2 2.5 3 3.5 pupil diameter [mm] 4 4.5 5 Contrast Sensitivity Day test _ aspheric _ spheric Contrast Sensitivity Night test _ aspheric _ spheric Contrast Sensitivity Day test with glare _ aspheric _ spheric Contrast Sensitivity Night test with glare _ aspheric _ spheric Conclusion o same visual acuity o most patients prefer the eye with the aspheric lens o better contrast sensitivity with the aspheric lens o less spherical aberrations with the aspheric lens Thank you