ROXUL AFB ® Sell Sheet
Transcription
ROXUL AFB ® Sell Sheet
Acoustical Fire Batt Insulation ROXUL AFB ® Acoustical Fire Batt Insulation for Commercial & Interior Partition Walls. ROXUL AFB ® Batt insulation that fights both fire and noise. ROXUL AFB ® ROXUL AFB is a lightweight, batt insulation specifically designed for steel stud interior wall and floor applications. ® This stone wool insulation is made from natural stone and recycled content. It’s a sustainable product that provides superior sound absorbency and fire protection for overall occupant comfort and safety. That’s why AFB is quickly becoming the insulation of choice for today’s green builders in commercial and industrial construction. AFB – Acoustically Better Sound Transmission Class (STC) values don’t take into account Lower Frequency Sounds (LFS) which can cause vibrations between rooms, negatively affecting the sound environment. The higher density of ROXUL AFB can reduce sound transmission, helping to create a quiet and comfortable space. Sound Control When ROXUL AFB is specified for interior wall or floor assemblies, better overall sound control and fire protection are achieved. Compared to other types of insulation, AFB provides increased density that effectively reduces airflow and essentially, sound transmissions. Greater noise or sound control is further achieved when thicker AFB and gypsum board are used together. AFB thickness ranges from 1.0” (25 mm) to 6” (152 mm). In commercial applications, much of the sound to be controlled is in the low frequency or bass ranges. This noise includes conversation, projection/video equipment, mechanical rooms and ventilation systems. In the lower 1/3 octave bands, ROXUL AFB outperforms glass wool insulation, providing more low frequency absorption when comparing acoustical testing at low frequencies (see chart “Random Incidence Sound Absorption Coefficients, in 1/3 Octave Band”, pg. 3). 2 Acoustical Fire Batt Insulation Density and Airflow Resistivity for Samples of Absorptive Material Density (kg/m3) Airflow Resistivity (mks rayls/m) Average Value Standard Deviation Average Value Standard Deviation Glass Fiber 3½” (89 mm) batt 12.2 0.4 4,800 400 Glass Fiber 2½” (65 mm) batt 11.7 1.0 3,600 200 ROXUL AFB 3” (75 mm) batt 44.2 1.7 16,600 900 ROXUL AFB 1½” (40 mm) batt 51.9 2.2 15,000 500 Random Incidence Sound Absorption Coefficients, in 1/3 Octave Band 1/3 Octave Band Center Frequency (Hz) 65 80 100 125 160 200 250 Glass Fiber Sample 1 3½” 0.15 0.18 0.21 0.25 0.32 0.43 0.54 Glass Fiber Sample 2 3½” 0.15 0.17 0.19 0.22 028 0.37 0.48 ROXUL AFB Sample 1 3” 0.18 0.22 0.28 0.33 0.40 0.50 0.62 ROXUL AFB Sample 2 3” 0.18 0.23 0.29 0.24 0.41 0.52 0.65 Glass Fiber Sample Average 3” 0.15 0.18 0.20 0.20 0.30 0.40 0.50 ROXUL AFB Sample Average 3” 0.18 0.23 0.29 0.34 0.41 0.51 0.64 Acoustical Performance ASTM E 90 Airborne Sound Transmission Loss Tested Rating Sound Insulation Tested Sound Absorption Coefficients Tested Impedance and Absorption of Acoustical Materials Tested ASTM E 413 ASTM C 423 ASTM E 1050 ASTM C423 Coefficients at Frequencies Thickness 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz NRC 1.0” 0.14 0.25 0.65 0.90 1.01 1.01 0.70 1.5” 0.18 0.44 0.94 1.04 1.02 1.03 0.85 2.0” 0.28 0.60 1.09 1.09 1.05 1.07 0.95 3.0” 0.52 0.96 1.18 1.07 1.05 1.05 1.05 4.0” 0.86 1.11 1.20 1.07 1.08 1.07 1.10 3 ROXUL AFB ® Features and benefits that set AFB apart. ® Fire Resistant Water Repellent ROXUL AFB is non-combustible and will not develop toxic smoke or promote flame spread, even when directly exposed to fire. AFB will therefore not add fuel to an existing fire, making it ideal for use in high occupancy buildings. Studies have shown that mineral wool insulated rooms provide a 54% increase in overall fire resistance rating compared to non-insulated rooms. ROXUL AFB will not absorb or hold water and will not promote mold or fungi growth. It has superior drying potential, effectively managing moisture in the event that it does get into the wall or floor, allowing it to dry out and maintain its sound and fire properties. ® Since stone wool does not contribute to a fire, it can provide valuable extra time for people to reach safety, a critical factor especially in health and education facilities. It can also provide fire services personnel additional time to control the spread of fire while reducing property damage. Fire Performance CAN4 S114 ASTM E 136 CAN/ULC S102 Test for Non-Combustibility Non-Combustible Behavior of Materials at 750 °C (1382 °F) Non-Combustible Surface Burning Characteristics Flame Spread = 0 Smoke Developed = 0 ASTM E84 (UL 723) Surface Burning Characteristics Flame Spread = 0 Smoke Developed = 0 CAN/ULC S129 4 Smolder Resistance 0.09% Acoustical Fire Batt Insulation Sag-Free, Tight Fit Fast, Easy Installation The higher density of AFB provides superior sag resistance and fit. Other insulations may sag or slump over time with the settlement or the vibrations of interior doors opening and closing. This creates gaps that will allow sound to travel through. AFB holds its shape without sagging or slumping in the wall cavity over time to consistently provide continuous fire protection and sound control. ® Working with ROXUL insulation is a breeze. Simply cut with a serrated knife for quick and efficient installation between studs, around electrical boxes, pipes, wiring, ductwork and between studs and joists that are less than a standard width. ® Corrosive Resistance ASTM C 665 ASTM C 795 **** Corrosiveness to Steel Pass Stainless Steel Stress Corrosion Specification as per Test Methods C871 and C692: U.S. Nuclear Regulatory Commission, Reg. Guide #1.36: U.S. Military Specifications MIL-I-24244 (all versions including B and C) Conforms Maximum Air Velocity 1000 fpm (5.08 m/s) Air Erosion UL 181 5 Roxul afb ® Compliance and performance. Mineral Fiber Thermal Insulation for Buildings Type 1, Complies ASTM C 665 CAN/ULC-S702-07 Mineral Fiber Blanket Thermal Insulation Type 1, Complies ASTM C 553 Mineral Fiber Blanket Thermal Insulation Complies New York City Approval 338-97-M MEA Approval City Of Los Angeles approval ULC Design Nos. RR 25444 U311, W406, W408, W419, W423, W440, W441, W442, W508, W600, Z500 UL Design Nos. U305, U311, U317, U411, U412, U448, U465, V417, V418, V419 Dimensions Thickness 16.25” (width) x 48” (length) 412.75 mm (width) x 1219 mm (length) 24.25” (width) x 48” (length) 615.95 mm (width) x 1219 mm (length) Density 2” thickness 2.8 lbs/ft3 45 kg/m3 For more information about AFB technical data and assembly details visit: ® Simplifying the Specification of Stone Wool for Commercial Projects www.rspec.com 6 Product thickness is available in 1” to 3.5” with ½” increments as well as 4”, 5” and 6” offerings. Acoustical Fire Batt Insulation Commercial wall system performance using ROXUL AFB . ® In the following 13 commercial wall systems, ROXUL AFB delivers excellent fire resistance ratings and Sound Transmission Class (STC). ® The right-hand column shows the results of acoustical tests done on these ROXUL AFB wall systems at the internationally-recognized Riverbank Acoustical Construction 1 Laboratories. For other wall constructions not shown here, please contact ROXUL technical services. For further details on the illustrated constructions, consult the UL or ULC Design Manual. All STC Ratings are based on Type X gypsum board. ® Description Single layer wall ⁄8” (15.9 mm) gypsum board 5 3 5⁄8” (92 mm) steel studs spaced 24” (610 mm) centers 3” (76 mm) ROXUL AFB Sound Transmission Class 52 (RAL-TL95-195) Transmission Loss Transmission loss (dB) 70 60 50 40 30 20 10 0 160 250 Fire Resistance 1 hour (UL design no. V417 and U465) 1 hour (ULC W447) 400 630 1000 1600 2500 4000 Frequency (Hz) Transmission loss (dB) 70 60 50 40 30 What is STC? 20 10 The Sound Transmission Class (STC) is a single-number rating of an assembly’s ability to resist 0 160 250 400 630 1000 1600 2500 4000 airborne sound transfer at the frequencies 125-4000 Hz. In general, a higher STC rating blocks Frequency (Hz) more noise from transmitting through a partition. Because stone wool is denser than fiberglass, ROXUL’s AFB insulation makes for a more soundproof environment.Transmission loss (dB) 70 60 50 40 30 20 10 7 0 160 250 400 630 1000 1600 2500 4000 Frequency (Hz) Roxul afb ® Construction 2 Description Single layer wall ½” (12.7 mm) gypsum board 3 ⁄8” (92 mm) steel studs spaced 24” (610 mm) centers 5 3” (76 mm) ROXUL AFB Sound Transmission Class 51 (RAL-TL96-269) Fire Resistance 1 hour (UL design no. U448 and ULC design no W433) 3 Single layer wall ½” (12.7 mm) gypsum board 3 5⁄8” (92 mm) steel studs spaced 24” (610 mm) centers 1½” (38 mm) ROXUL AFB Sound Transmission Class 46 (RAL-TL90-195) Fire Resistance 1 hour (UL design no. U448 and ULC design no W433) 50 5 40 Transmission loss (dB) 30 70 4 T 3 7 20 60 2 6 10 50 Transmission loss (dB) 0 40 70 160 250 400 630 1000 30 Transmission Loss 60 20 50 10 Transmission loss (dB) 40 0 70 30 160 250 400 630 1000 60 20 50 10 1 5 T 4 1600 2500 4000 Frequency (Hz) 1600 2500 4000 Frequency (Hz) Frequency (Hz) 10 50 Transmission loss (dB) 0 40 70 160 250 400 630 1000 1600 2500 4000 30 60 Frequency (Hz) 20 50 10 Transmission loss (dB) 40 0 70 30 160 250 400 630 1000 1600 2500 4000 60 20 Frequency (Hz) 50 10 400 Transmission loss (dB) 160 250 400 630 1000 1600 2500 4000 30 70 Frequency (Hz) 20 60 10 50 Transmission loss (dB) 0 40 70 160 250 400 630 1000 1600 2500 4000 30 60 Frequency (Hz) 20 50 10 Transmission loss (dB) 40 0 70 30 160 250 400 630 1000 1600 2500 4000 60 20 Frequency (Hz) 50 10 400 Transmission loss (dB) 160 250 400 630 1000 1600 2500 4000 30 70 4 Sound Transmission Class 10 50 Transmission loss (dB) 0 40 70 160 250 400 630 1000 1600 2500 4000 30 60 Frequency (Hz) 20 50 10 40 0 30 160 250 400 630 1000 1600 2500 4000 20 Frequency (Hz) 46 (RAL-TL96-270) 10 Single layer wall ⁄8” (15.9 mm) gypsum board 5 2½” (64 mm) steel studs spaced 24” (610 mm) centers 2½” (64 mm) ROXUL AFB Fire Resistance 1 hour (NBC of Canada 1995 and UL design no. U448) 8 Frequency (Hz) 20 60 0 160 250 400 2 1 T 7 6 5 400 Transmission loss (dB) 160 250 400 630 1000 1600 2500 4000 30 70 20 60 3 630 1000 1600 2500 4000 Frequency (Hz) 4 T 3 7 2 6 1 5 T 4 3 2 1 T 7 6 5 4 T 3 7 2 6 1 5 T 4 3 2 1 T 7 6 5 4 T 3 7 2 6 1 5 T 4 3 2 1 Acoustical Fire Batt Insulation Construction 5 Description Transmission loss (dB) Single layer wall 70 Transmission loss (dB) 70 60 2½”loss (64(dB) mm) steel studs spaced Transmission 50 24” (610 mm) centers 70 40 60 2½” (64 mm) ROXUL AFB 30 50 Sound Transmission Class 20 40 44 (RAL-TL96-285) 10 Transmission loss (dB) 30 Fire Resistance 0 70 20 160 250 400 630 1000 1600 2500 4000 1 hour (UL design no. U448 and 60 10 Frequency (Hz) ULC design no W433) 50 0 60 Transmission loss (dB) 50 70 40 60 30 50 20 40 10 Transmission loss (dB) 30 0 70 20 160 250 400 630 1000 1600 2500 4000 60 10 Frequency (Hz) 50 0 40 160 250 400 630 1000 1600 2500 4000 Transmission loss (dB) Frequency (Hz) 30 70 40 160 250 400 630 1000 1600 2500 4000 Transmission loss (dB) Frequency (Hz) 30 70 20 60 Transmission loss (dB) Single layer wall with resilient 10 50 70 metal channels on one side 0 40 60 160 5⁄250 400 mm) 630 gypsum 1000 1600board 2500 4000 8” (15.9 30 50 Frequency (Hz) 5 3 ⁄8” (92 mm) steel studs spaced 20 40 24” (610 mm) centers 10 Transmission loss (dB) 30 Resilient metal channels spaced 0 70 20 24” 1600 (610 2500 mm)4000 centers 160 horizontally 250 400 630at1000 60 10 Frequency (Hz) 3” (76 mm) ROXUL AFB 50 0 20 60 Transmission loss (dB) 10 50 70 0 40 60 160 250 400 630 1000 1600 2500 4000 30 50 Frequency (Hz) 20 40 10 Transmission loss (dB) 30 0 70 20 160 250 400 630 1000 1600 2500 4000 60 10 Frequency (Hz) 50 0 ½” (12.7 mm) gypsum board 6 7 Transmission Loss Transmission 630 1000 1600Class 2500 4000 250 400 40 160 Sound Transmission loss (dB) 30 55 (RAL-TL96-289)Frequency (Hz) 70 20 Fire Resistance 60 Transmission loss (dB) 10 50 1 hour (UL design no. V417 and U465) 70 0 1 hour (ULC W447) 40 60 160 250 400 630 1000 1600 2500 4000 30 50 Frequency (Hz) 20 40 10 Transmission loss (dB) 30 Single layer wall with resilient 0 70 metal channels on one side 20 160 250 400 630 1000 1600 2500 4000 60 ½” (12.7 mm) gypsum board 10 Frequency (Hz) 50 5 0 40 160 250 400 630 1000 1600 2500 4000 Transmission loss (dB) Frequency (Hz) 30 70 20 60 Transmission loss (dB) 10 50 70 0 40 60 160 250 400 630 1000 1600 2500 4000 30 50 Frequency (Hz) 20 40 10 Transmission loss (dB) 30 0 70 20 160 250 400 630 1000 1600 2500 4000 60 10 Frequency (Hz) 50 0 250 400 630 1000 1600 2500 4000 40 160 24” (610 mm) centers Transmission loss (dB) Frequency (Hz) 30 70 Resilient metal channels spaced 20 60 horizontally at 24” (610 mm) centers Transmission loss (dB) 10 50 3” (76 mm) ROXUL AFB 70 0 40 60 Transmission 160 Sound 630 1000 1600Class 2500 4000 250 400 30 50 Frequency (Hz) 53 (RAL-TL96-288) 20 40 Fire Resistance 10 Transmission loss (dB) 30 1 hour (UL design no. U448) 0 70 20 160 250 400 630 1000 1600 2500 4000 60 10 Frequency (Hz) 50 0 40 160 250 400 630 1000 1600 2500 4000 Transmission loss (dB) Frequency (Hz) 30 70 20 60 Transmission loss (dB) 10 50 70 0 40 60 160 250 400 630 1000 1600 2500 4000 30 50 Frequency (Hz) 20 40 10 Transmission loss (dB) 30 0 70 20 160 250 400 630 1000 1600 2500 4000 60 10 Frequency (Hz) 50 0 3 ⁄8” (92 mm) steel studs spaced 40 30 160 250 400 630 1000 1600 2500 4000 Frequency (Hz) 40 30 20 20 10 10 160 250 400 630 1000 1600 2500 4000 9 Frequency (Hz) Roxul afb ® 50 50 5 40 40 4 30 30 3 20 20 2 10 10 1 0 0 160 250 Construction 8 400 160 250 630 1000 1600 2500 4000 Description Frequency (Hz) 400 630 1000 1600 2500 4000 Transmission Loss Frequency (Hz) TransmissionUnbalanced loss (dB) wall 70 5 Transmission loss (dB) 70 T 7 60 60 6 50 5 40 4 30 3 20 2 10 1 ⁄8” (15.9 mm) gypsum board, single layer one side; double layer other 50 3 5⁄8” (92 mm) steel studs spaced 24” (610 mm) centers 40 30 3” (76 mm) ROXUL AFB/ 3½” (89 mm) AFB 20 10 0 Sound Transmission Class 160 250 400 0 630 1000 1600 2500 4000 160 250 400 630 1000 1600 2500 4000 56 (RAL-TL96-264) Frequency (Hz) Frequency (Hz) Fire Resistance 1½ hour (NBC of Canada 1995)* 1 hour (UL design no. V417) * NB. 3½” (89 mm) AFB only s (dB) 9 Transmission loss (dB) Unbalanced wall 70 Transmission loss (dB) 70 T 7 60 60 6 ½” (12.7 mm) gypsum board, single layer one side; double layer other 50 (dB) 2½” (64 mm) steel studs spaced centers Transmission loss (dB) 40 24” (610 mm) 70 30 1½” (38 mm) ROXUL AFB 60 20 50 10 400 630 1000 1600 2500 4000 Frequency (Hz) s (dB) 00 630 1000 1600 2500 4000 Frequency (Hz) 400 630 1000 1600 2500 4000 Frequency (Hz) s (dB) 00 630 1000 1600 2500 4000 Frequency (Hz) (dB) 400 Sound Transmission Class 50 (RAL-TL90-186) 160 250 400 630 1000 1600 2500 4000 Fire Resistance 20 Frequency (Hz) 10 1 hour (NBC of Canada 1995 Transmission loss (dB) 0 and UL design no. U448) 70 160 250 400 630 1000 1600 2500 4000 60 Frequency (Hz) 50 10 (dB) 400 30 10 630 1000 1600 2500 4000 5 50 Transmission loss (dB) 40 70 30 Tr 4 70 3 60 20 50 10 60 2 50 1 400 30 40 160 250 400 630 1000 1600 2500 4000 30 Frequency (Hz) 20 10 Transmission loss (dB) 0 70 160 250 400 630 1000 1600 2500 4000 60 Frequency (Hz) 10 T 0 7 20 50 6 5 Transmission loss (dB)layer wall 40 Double 70 30 5 Transmission loss (dB) 40 70 30 Tr 4 70 3 60 20 50 10 60 20 50 10 60 2 50 1 400 30 20 2 layers of ⁄8” (15.9 mm) gypsum board on both sides 160 3 5⁄8” (92 mm) steel studs spaced 24” (610 mm) centers 250 400 630 1000 1600 2500 4000 3” (76 mm) ROXULFrequency AFB (Hz) 10 Sound Transmission Class Transmission loss (dB) 0 57 (RAL-TL96-268) 70 160 250 400 630 1000 1600 2500 4000 60 Fire Resistance Frequency (Hz) 50 2 hours (UL design no. U411 NBC of Canada 1995) 400 30 40 160 250 400 630 1000 1600 2500 4000 30 Frequency (Hz) 20 10 Transmission loss (dB) 0 70 160 250 400 630 1000 1600 2500 4000 60 Frequency (Hz) 10 T 0 7 20 50 6 5 Transmission lossV419, (dB) 40 and 70 30 Transmission loss (dB) 40 70 30 Tr 4 70 3 60 20 50 10 60 20 50 10 60 2 50 1 400 30 400 30 40 160 250 400 630 1000 1600 2500 4000 160 250 400 630 1000 1600 2500 4000 30 oss (dB) Acoustical Fire Batt Insulation 400 630 1000 1600 2500 4000 Construction Frequency (Hz) 11 oss (dB) 400 630 1000 1600 2500 4000 Frequency (Hz) Transmission loss (dB) 40 70 30 60 20 50 10 40 0 30 160 250 400 630 1000 1600 2500 4000 20 Description Frequency (Hz) 10 Transmission loss (dB) 40 70 30 60 20 50 10 40 0 30 160 250 400 630 1000 1600 2500 4000 20 Transmission Loss Frequency (Hz) 10 0 Transmission loss (dB) Double layer wall 70 160 250 400 630 1000 1600 2500 4000 2 layers of ½” (12.7Frequency mm) (Hz) 60 0 Transmission loss (dB) 70 160 250 400 630 1000 1600 2500 4000 Frequency (Hz) 60 50 Transmission 3 5⁄8loss ” (92(dB) mm) steel studs spaced 40 70 24” (610 mm) centers 30 60 20 1½” (38 mm) ROXUL AFB 50 10 40 Sound Transmission Class 0 30 160 56 400 630 1000 1600 2500 4000 250(RAL-TL90-196) 20 Fire Resistance Frequency (Hz) 10 50 Transmission loss (dB) 40 70 30 60 20 50 10 40 0 30 160 250 400 630 1000 1600 2500 4000 20 Frequency (Hz) 10 gypsum board on both sides oss (dB) 400 630 1000 1600 2500 4000 Frequency (Hz) oss (dB) 400 630 1000 1600 2500 4000 Frequency (Hz) 12 oss (dB) 400 630 1000 1600 2500 4000 Frequency (Hz) 2 hours (UL design no. U412 and 0 Transmission loss (dB) 160 400 630 1000 1600 2500 4000 250 70 Frequency (Hz) 60 50 Transmission loss (dB) Double layer wall 40 70 2 layers of 5⁄8” (15.9 mm) 30 60 gypsum board on both sides 20 50 10 2½” (64 mm) steel studs spaced 40 0 24” (610 mm) centers 30 160 250 400 630 1000 1600 2500 4000 20 1½” (38 mm) ROXUL AFB Frequency (Hz) 10 0 400 V418) 630 1000 1600 2500 4000 Frequency (Hz) Sound Transmission Class 160 56 400 630 1000 1600 2500 4000 250(RAL-TL90-193) Fire Resistance 0 Transmission loss (dB) 70 160 250 400 630 1000 1600 2500 4000 Frequency (Hz) 60 50 Transmission loss (dB) 40 70 30 60 20 50 10 40 0 30 160 250 400 630 1000 1600 2500 4000 20 Frequency (Hz) 10 0 160 250 400 Frequency (Hz) 630 1000 1600 2500 4000 Frequency (Hz) 2 hours (UL design no. U411 and V419, NBC of Canada) loss (dB) 13 Transmission loss (dB) Double layer wall 70 Transmission loss (dB) 70 60 60 50 30 20 1½” (38 mm) ROXUL AFB 20 10 Sound Transmission Class 10 0 400 630 1000 1600 2500 4000 Frequency (Hz) loss (dB) 50 2½” (64 mm) steel studs spaced 24” (610 mm) centers 40 0 2 layers of ½” (12.7 mm) gypsum board on both sides (RAL-TL90-185) 160 53 400 630 1000 1600 2500 4000 250 Fire Resistance 2 hours (UL Transmission loss (dB) 70 40 30 0 160 250 400 Frequency (Hz) design no. U412 and V418) 630 1000 1600 2500 4000 Frequency (Hz) Transmission loss (dB) 70 60 60 50 50 40 40 30 30 20 20 10 10 11 ROXUL AFB ® A global leader Environmentally sustainable ROXUL Inc. is part of ROCKWOOL International, the largest producer of stone wool insulation, which is made from natural basalt rock and recycled material. ROCKWOOL International was founded in 1909 and today operates worldwide withmore than 9,700 employees, with 26 factories across three continents. Our stone wool production process utilizes some of the most advanced technology available. The ROXUL facility is designed to capture and recycle rainwater, reduce energy consumption, and create zero waste to landfill by recycling raw materials back into the production process. ROCKWOOL has more than 40 years experience in developing and manufacturing advanced wall system products. For more than 25 years, ROXUL has been serving the North American market. ROXUL insulations are created using naturally occurring, inorganic raw materials and materials with a high-recycled content. Stone wool insulation is non-combustible and achieves its thermal performance without the use of blowing agents. The products do not off-gas and are fully recyclable, therefore contributing to a sustainable environment. ® In addition to residential insulation, ROXUL also manufactures a range of other premium insulation products for commercial and industrial applications. ROXUL is The Better Insulation TM ROXUL AFB® is an innovative insulation offering a world of green features. When ROXUL is the specified insulation, green building developers can earn a variety of LEED® (Leadership in Energy and Environmental Design) points across four key categories toward sustainable development. TM 2012-2013 ROXUL is pleased to have third-party certification of our products’ recycled content for our Milton facility, completed by ICC-ES SAVE™. All ROXUL products produced at the Milton facility contain a minimum of 40% recycled content. For further details, contact your ROXUL Sales Representative. Please visit www.roxul.com for the latest information. ROXUL INC. 420 Bronte Street South Suite 105, Milton, Ontario L9T 0H9 Tel: 1-800-265-6878 www.roxul.com AFB® is a registered trademark of ROXUL Inc. LEED ® is a registered trademark of United States Green Building Council. GREENGUARD ® is a registered trademark of Greenguard Environmental Institute. ROX-2481_1013
Similar documents
Acoustical Fire Batts
The capability of an insulating material to absorb sound waves is expressed by the sound absorption coefficients. The higher the coefficients, the better the sound absorption. Clearly ROXUL AFB
More information