tnxTower - St. Charles Tower
Transcription
tnxTower - St. Charles Tower
Reviewed by: Chris Sekol, S.E. IL License #081-005857 Page 2 of 3 10/9/2012 Project Summary: We have completed a structural analysis of the existing Self-Support Tower to be moved to the proposed site, and installed on a new foundation design. The tower was manufactured by Pirod in 2001 as a 300’ structure, but only the lower 240’ of the tower is to be utilized at this site. The tower has been analyzed in accordance with the requirements of the International Building Code per IBC section 3108.4, and the recommendations of the Telecommunications Industry Association “Structural Standard for Steel Antenna Supporting Structures” ANSI/TIA-222-G. Source of Data: Resource Tower Drawings Geotechnical Report Source Pirod, Inc. Noble Engineering Job Number U-30.0 x 300' Date 08/20/01 01/13/12 Design Criteria: International Building Code (All Versions) Section 3108.4 Structural Standards for Steel Antenna Supporting Structures ANSI/TIA-222-G 2 Basic Wind Speed Basic Wind Speed w/ 1” Ice Operational Wind Speed Structure Class II (I = 1.0) 90 mph (3-Sec Gust) 40 mph (3-Sec Gust) 60 mph (3-Sec Gust) Exposure Category C Topographic Category I Appurtenance Listing: Elev. Antenna / Mounting (9) 72" x 12" x 3" Panel Boom Mounts (9) 72" x 12" x 3" Panel Boom Mounts (9) 72" x 12" x 3" Panel Boom Mounts (1) XA XOA-700-11 Omni Side Arm Mount 230' 220' 210' 160' Coax Location (9) 1 5/8" Face C (9) 1 5/8" Face C (9) 1 5/8" Face C (1) CAT 5 Face C Recommendations: We recommend verification that the tower matches the original design drawings, and that the tower members are in as-new structural condition and free from corrosion. mike@mfpeng.com Page 3 of 3 10/9/2012 Standard Conditions for Providing Structural Consulting Services on Existing Structures 1. The following standard conditions are a general overview of key issues regarding the work product supplied. 2. If the existing conditions are not as represented in this structural report or attached sketches, we should be contacted to evaluate the significance of the deviation and revise the structural assessment accordingly. 3. The structural analysis has been performed assuming that the structure is in “like new” condition. No allowance was made for excessive corrosion, damaged or missing structural members, loose bolts, etc. If there are any known deficiencies in the structure that potentially compromise structural integrity, we should be made aware of the deficiencies. If we are aware of a deficiency that exists in a structure at the time of our analysis, a general explanation of the structural concern due to the deficiency will be included in the structural report, but the deficiency will not be reflected in capacity calculations. 4. The structural analysis provided is an assessment of the primary load carrying capacity of the structure. We provide a limited scope of service in that we have not verified the capacity of every weld, plate, connection detail, etc. In most cases, structural fabrication details are unknown at the time of our analysis, and the detailed field measurement of this information is beyond the scope of our services. In instances where we have not performed connection capacity calculations, it is assumed that existing manufactured connections develop the full capacity of the primary members being connected. 5. Miscellaneous items such as antenna mounts, coax supports, etc. have not been designed, detailed, or specified as part of our work. It is assumed that material of adequate size and strength will be purchased from a reputable component manufacturer. The attached report and sketches are schematic in nature and should not be used to fabricate or purchase hardware and accessories to be attached to the structure. We recommend field measurement of the structure before fabricating or purchasing new hardware and accessories. We are not responsible for proper fit and clearance of hardware and accessory items in the field. 6. The structural analysis has been performed considering minimum code requirements or recommendations. If alternate wind, ice, or deflection criteria are to be considered, then We shall be made aware of the alternate criteria. mike@mfpeng.com Page 1 of 1 Eng: MFP Structure: Site: Location: Owner: Revision No.: CL LEG 8'-0" LONG ANCHOR ROD 10"-12" PROJECTION 3" GAP (GROUT NOT REQ'D.) 6" ABOVE GRADE 2" CLEAR FINISHED GRADE 25'-0" MIN. CAISSON DEPTH 7'-0" MIN. AB EMBEDMENT (2) ADD'L REINF TIES WITHIN THE TOP 5" OF CAISSON #4 HOR. TIES SPACED @ 9" O/C WITHIN THE TOP AND BOTTOM 7'-0" OF PIER. REMAINDER OF PIER 18" O/C. 3" CLEAR (TYP) CLOSE TIES WITH MIN. 24" LAP (20) #9 VERTICAL REINF BARS EQUALLY SPACED 6" CLEAR 5'-0"Ø DRILLED SHAFT CAISSON TYP OF 3 Job Number: 24112-007 Customer Ref: Date: 10/9/2012 240-FT SELF SUPPORT TOWER 2012-05 CHRISTOPHER FRANKLIN CO., IL - 37°59'24", -89°2'13" ST. CHARLES TOWER Revision Date: 1.2 240 230 220 210 160 DESIGNED APPURTENANCE LOADING 1.3 TYPE 2.5 8 220.0 ft 10 200.0 ft 3.0 N.A. L3x3x3/16 180.0 ft 3.0 12 T4 Pirod 105218 (12x1.75) 230 (3) 72"x12"x3" panels 230 (3) 72"x12"x3" panels 230 (3) TMA 230 (3) TMA 230 (3) TMA 230 PiROD 12' Universal T-Frame Sector Mount 230 PiROD 12' Universal T-Frame Sector Mount 18 @ 10 PiROD 12' Universal T-Frame Sector Mount 220 (3) 72"x12"x3" panels 210 (3) 72"x12"x3" panels 210 (3) 72"x12"x3" panels 210 (3) TMA 210 (3) TMA 210 230 (3) TMA 210 210 PiROD 12' Universal T-Frame Sector Mount 230 PiROD 12' Universal T-Frame Sector Mount 210 (3) 72"x12"x3" panels 220 PiROD 12' Universal T-Frame Sector Mount (3) 72"x12"x3" panels 220 220 PiROD 12' Universal T-Frame Sector Mount 210 (3) 72"x12"x3" panels (3) TMA 220 12 ft x 2" dia whip 160 (3) TMA 220 3' Side Arm Mount 160 (3) TMA 220 PiROD 12' Universal T-Frame Sector Mount 220 SYMBOL LIST C 2.4 15 ELEVATION 220 2.1 L 3 x 3 x 5/16 SIZE MARK SIZE A Pirod 112738 (18x2.5) C L 3 x 3 x 5/16 B L 2.5 x 2.5 x 3/16 D L3 1/2x3 1/2x5/16 16 GRADE 130.0 ft A572-50 120.0 ft 1. 2. 3. 4. Fy 50 ksi Fu 65 ksi 2.7 17 2.3 N.A. MATERIAL STRENGTH D 5. 6. 7. 8. 20 Fy 36 ksi Fu 58 ksi Tower is located in Franklin County, Illinois. Tower designed for Exposure C to the TIA-222-G Standard. Tower designed for a 90.00 mph basic wind in accordance with the TIA-222-G Standard. Tower is also designed for a 40.00 mph basic wind with 1.00 in ice. Ice is considered to increase in thickness with height. Deflections are based upon a 60.00 mph wind. Tower Structure Class II. Topographic Category 1 with Crest Height of 0.00 ft TOWER RATING: 86.7% 5.3 L 4 x 4 x 1/4 GRADE A36 TOWER DESIGN NOTES 4.8 N.A. 18 A36 A572-50 L3 1/2x3 1/2x5/16 (3) 72"x12"x3" panels TYPE PiROD 12' Universal T-Frame Sector Mount 140.0 ft 22 80.0 ft ALL REACTIONS ARE FACTORED N.A. 6.4 L4x4x3/8 MAX. CORNER REACTIONS AT BASE: DOWN: 432 K UPLIFT: -364 K SHEAR: 52 K Pirod 112743 7.9 T13 24 60.0 ft AXIAL 304 K 3 @ 20 SHEAR 20 K 20.0 ft A 8.2 28 T14 2L 3.5 x 3.5 x 5/16 (1) 26 40.0 ft 8.1 T11 Pirod 105220 (12x2.25) T12 240 MARK 150.0 ft 100.0 ft T15 ELEVATION Flash Beacon Lighting 160.0 ft 14 T5 T6 T7 T8 T10 T9 Pirod 105219 (12x2) 3' Side Flash (3) PiROD 12 ftTMA 72"x12"x3" xBeacon 2" Arm 12' dia Universal Mount whip Lighting panelsT-Frame Sector Mount 230.0 ft 7 B N.A. L3x3x3/16 T2 T3 Pirod 105217 (12x1.5) T1 L 2.5 x 2.5 x 3/16 6 240.0 ft MOMENT 2945 kip-ft TORQUE 9 kip-ft 40.00 mph WIND - 1.00 in ICE AXIAL 86 K SHEAR 79 K MOMENT 10481 kip-ft 61.2 TORQUE 44 kip-ft REACTIONS - 90.00 mph WIND Weight (K) # Panels @ (ft) Face Width (ft) Sec. Horizontals Top Girts Diagonal Grade Diagonals Leg Grade Legs Section 30 0.0 ft Michael F. Plahovinsak, P.E. Job: 240-ft S/S Tower - MFP #24112-007 18301 State Route 161 W Plain City, OH 43064 Phone: 614-398-6250 FAX: mike@mfpeng.com Project: 2012-05, Client: Code: Path: Christopher St. Charles Tower Drawn by: Mike Date: TIA-222-G 10/09/12 J:\Projects\241-St. Charles Tower\24112-007\24112-007 r1.eri App'd: Scale: NTS E-1 Dwg No. tnxTower Michael F. Plahovinsak, P.E. 18301 State Route 161 W Plain City, OH 43064 Phone: 614-398-6250 FAX: mike@mfpeng.com Page Job 1 of 26 240-ft S/S Tower - MFP #24112-007 Project Date 2012-05, Christopher Client 12:26:46 10/09/12 Designed by St. Charles Tower Mike Tower Input Data The main tower is a 3x free standing tower with an overall height of 240.00 ft above the ground line. The base of the tower is set at an elevation of 0.00 ft above the ground line. The face width of the tower is 6 ft at the top and 30 ft at the base. This tower is designed using the TIA-222-G standard. The following design criteria apply: Tower is located in Franklin County, Illinois. Basic wind speed of 90.00 mph. Structure Class II. Exposure Category C. Topographic Category 1. Crest Height 0.00 ft. Nominal ice thickness of 1.00 in. Ice thickness is considered to increase with height. Ice density of 56 pcf. A wind speed of 40.00 mph is used in combination with ice. Deflections calculated using a wind speed of 60.00 mph. A non-linear (P-delta) analysis was used. Pressures are calculated at each section. Stress ratio used in tower member design is 1. Local bending stresses due to climbing loads, feedline supports, and appurtenance mounts are not considered. Wind 180 Leg A Fa c Leg C eB eA c Fa Wind 90 X Z Leg B Fac e C Wind Norma l Triangular To wer Page Job tnxTower 2 of 26 240-ft S/S Tower - MFP #24112-007 Project Michael F. Plahovinsak, P.E. Date 2012-05, Christopher 18301 State Route 161 W Plain City, OH 43064 Phone: 614-398-6250 FAX: mike@mfpeng.com 12:26:46 10/09/12 Client Designed by St. Charles Tower Mike Tower Section Geometry Tower Section Tower Elevation T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 T13 T14 T15 ft 240.00-230.00 230.00-220.00 220.00-200.00 200.00-180.00 180.00-160.00 160.00-150.00 150.00-140.00 140.00-130.00 130.00-120.00 120.00-100.00 100.00-80.00 80.00-60.00 60.00-40.00 40.00-20.00 20.00-0.00 Assembly Database Description Section Width Number of Sections ft 6 7 8 10 12 14 15 16 17 18 20 22 24 26 28 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Section Length ft 10.00 10.00 20.00 20.00 20.00 10.00 10.00 10.00 10.00 20.00 20.00 20.00 20.00 20.00 20.00 Tower Section Geometry (cont’d) Tower Section Tower Elevation Diagonal Spacing Bracing Type T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 T13 T14 T15 ft 240.00-230.00 230.00-220.00 220.00-200.00 200.00-180.00 180.00-160.00 160.00-150.00 150.00-140.00 140.00-130.00 130.00-120.00 120.00-100.00 100.00-80.00 80.00-60.00 60.00-40.00 40.00-20.00 20.00-0.00 ft 10 10 10 10 10 10 10 10 10 10 10 10 20 20 20 X Brace X Brace X Brace X Brace X Brace X Brace X Brace X Brace X Brace X Brace X Brace X Brace X Brace X Brace X Brace Has K Brace End Panels No No No No No No No No No No No No No No No Has Horizontals Top Girt Offset Bottom Girt Offset No Yes No No No No No No No No No No No No No in 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 in 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Tower Section Geometry (cont’d) Tower Elevation ft T1 240.00-230.00 Leg Type Leg Size Leg Grade Diagonal Type Diagonal Size Diagonal Grade Truss Leg Pirod 105217 (12x1.5) Single Angle L 2.5 x 2.5 x 3/16 T2 230.00-220.00 Truss Leg Pirod 105217 (12x1.5) Single Angle L 2.5 x 2.5 x 3/16 T3 220.00-200.00 Truss Leg Pirod 105217 (12x1.5) A572-50 (50 ksi) A572-50 (50 ksi) A572-50 (50 ksi) Single Angle L3x3x3/16 A36 (36 ksi) A36 (36 ksi) A36 (36 ksi) 3 of 26 240-ft S/S Tower - MFP #24112-007 Michael F. Plahovinsak, P.E. 18301 State Route 161 W Plain City, OH 43064 Phone: 614-398-6250 FAX: mike@mfpeng.com Page Job tnxTower Project Date 2012-05, Christopher 12:26:46 10/09/12 Client Designed by St. Charles Tower Mike Tower Elevation ft T4 200.00-180.00 Leg Type Leg Size Leg Grade Diagonal Type Diagonal Size Diagonal Grade Truss Leg Pirod 105218 (12x1.75) Single Angle L3x3x3/16 T5 180.00-160.00 Truss Leg Pirod 105218 (12x1.75) Single Angle L3x3x3/16 T6 160.00-150.00 Truss Leg Pirod 105219 (12x2) Single Angle L 3 x 3 x 5/16 T7 150.00-140.00 Truss Leg Pirod 105219 (12x2) Single Angle L 3 x 3 x 5/16 T8 140.00-130.00 Truss Leg Pirod 105219 (12x2) Single Angle L3 1/2x3 1/2x5/16 T9 130.00-120.00 Truss Leg Pirod 105219 (12x2) Single Angle L3 1/2x3 1/2x5/16 T10 120.00-100.00 T11 100.00-80.00 Truss Leg Pirod 105219 (12x2) Single Angle L3 1/2x3 1/2x5/16 Truss Leg Pirod 105220 (12x2.25) Single Angle L 4 x 4 x 1/4 T12 80.00-60.00 Truss Leg Pirod 105220 (12x2.25) Single Angle L4x4x3/8 T13 60.00-40.00 Truss Leg Pirod 112743 Double Angle 2L 3.5 x 3.5 x 5/16 (1) T14 40.00-20.00 Truss Leg Pirod 112743 Double Angle 2L 3.5 x 3.5 x 5/16 (1) T15 20.00-0.00 Truss Leg Pirod 112738 (18x2.5) A572-50 (50 ksi) A572-50 (50 ksi) A572-50 (50 ksi) A572-50 (50 ksi) A572-50 (50 ksi) A572-50 (50 ksi) A572-50 (50 ksi) A572-50 (50 ksi) A572-50 (50 ksi) A572-50 (50 ksi) A572-50 (50 ksi) A572-50 (50 ksi) Double Angle 2L 3.5 x 3.5 x 5/16 (1) A36 (36 ksi) A36 (36 ksi) A36 (36 ksi) A36 (36 ksi) A36 (36 ksi) A36 (36 ksi) A36 (36 ksi) A36 (36 ksi) A36 (36 ksi) A36 (36 ksi) A36 (36 ksi) A36 (36 ksi) Tower Section Geometry (cont’d) Tower Top Girt Elevation Type ft T1 240.00-230.00 Single Angle Top Girt Size Top Girt Grade Bottom Girt Type L 2.5 x 2.5 x 3/16 Single Angle T7 150.00-140.00 Single Angle L 3 x 3 x 5/16 T9 130.00-120.00 Single Angle L3 1/2x3 1/2x5/16 A36 (36 ksi) A36 (36 ksi) A36 (36 ksi) Bottom Girt Size Bottom Girt Grade A36 (36 ksi) A36 (36 ksi) A36 (36 ksi) Single Angle Single Angle Tower Section Geometry (cont’d) Tower Elevation Secondary Horizontal Type ft T2 230.00-220.00 Single Angle Secondary Horizontal Size Secondary Horizontal Grade Inner Bracing Type L3x3x3/16 A36 (36 ksi) Solid Round Inner Bracing Size Tower Section Geometry (cont’d) Inner Bracing Grade A36 (36 ksi) Page Job tnxTower 4 of 26 240-ft S/S Tower - MFP #24112-007 Michael F. Plahovinsak, P.E. 18301 State Route 161 W Plain City, OH 43064 Phone: 614-398-6250 FAX: mike@mfpeng.com Project Date 2012-05, Christopher 12:26:46 10/09/12 Client Designed by St. Charles Tower Tower Elevation Gusset Area (per face) Gusset Thickness ft T1 240.00-230.00 T2 230.00-220.00 T3 220.00-200.00 T4 200.00-180.00 T5 180.00-160.00 T6 160.00-150.00 T7 150.00-140.00 T8 140.00-130.00 T9 130.00-120.00 T10 120.00-100.00 T11 100.00-80.00 T12 80.00-60.00 T13 60.00-40.00 T14 40.00-20.00 T15 20.00-0.00 ft2 0.00 in 0.00 0.00 0.00 0.00 0.50 0.00 0.50 0.00 0.50 0.00 0.50 0.00 0.50 0.00 0.50 0.00 0.50 0.00 0.50 0.00 0.50 0.00 0.50 0.00 0.50 0.00 0.50 0.00 0.50 Gusset Grade Adjust. Factor Af A36 (36 ksi) A36 (36 ksi) A36 (36 ksi) A36 (36 ksi) A36 (36 ksi) A36 (36 ksi) A36 (36 ksi) A36 (36 ksi) A36 (36 ksi) A36 (36 ksi) A36 (36 ksi) A36 (36 ksi) A36 (36 ksi) A36 (36 ksi) A36 (36 ksi) Adjust. Factor Ar Mike Weight Mult. Double Angle Double Angle Stitch Bolt Stitch Bolt Spacing Spacing Diagonals Horizontals in in 1.05 54.00 36.00 1 1 1 1 1.05 36.00 36.00 1 1 1.05 36.00 36.00 1 1 1.05 36.00 36.00 1 1 1.05 36.00 36.00 1 1 1.05 36.00 36.00 1 1 1.05 36.00 36.00 1 1 1.05 36.00 36.00 1 1 1.05 36.00 36.00 1 1 1.05 36.00 36.00 1 1 1.05 36.00 36.00 1 1 1.05 36.00 36.00 1 1 1.05 36.00 36.00 1 1 1.05 36.00 36.00 1 1 1.05 36.00 36.00 Tower Section Geometry (cont’d) Tower Elevation ft T1 240.00-230.00 T2 230.00-220.00 T3 220.00-200.00 T4 200.00-180.00 T5 180.00-160.00 T6 160.00-150.00 T7 150.00-140.00 T8 Calc K Single Angles Calc K Solid Rounds Legs Yes No 1 Yes No 1 Yes No 1 Yes No 1 Yes No 1 Yes No 1 Yes No 1 Yes No 1 X Brace Diags X Y 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 K Brace Diags X Y 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 K Factors1 Single Girts Diags X Y 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 X Y 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Horiz. Sec. Horiz. Inner Brace X Y 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 X Y 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 X Y 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 tnxTower Michael F. Plahovinsak, P.E. 18301 State Route 161 W Plain City, OH 43064 Phone: 614-398-6250 FAX: mike@mfpeng.com Tower Elevation Calc K Single Angles Calc K Solid Rounds Page Job 5 of 26 240-ft S/S Tower - MFP #24112-007 Project Date 2012-05, Christopher 12:26:46 10/09/12 Client Designed by St. Charles Tower Mike K Factors1 Single Girts Diags Legs X K Horiz. Sec. Inner Brace Brace Horiz. Brace Diags Diags X X X X X X X ft Y Y Y Y Y Y Y 140.00-130.00 1 1 1 1 1 1 1 T9 Yes No 1 1 1 1 1 1 1 1 130.00-120.00 1 1 1 1 1 1 1 T10 Yes No 1 1 1 1 1 1 1 1 120.00-100.00 1 1 1 1 1 1 1 T11 Yes No 1 1 1 1 1 1 1 1 100.00-80.00 1 1 1 1 1 1 1 T12 Yes No 1 1 1 1 1 1 1 1 80.00-60.00 1 1 1 1 1 1 1 T13 Yes No 1 1 1 1 1 1 1 1 60.00-40.00 1 1 1 1 1 1 1 T14 Yes No 1 1 1 1 1 1 1 1 40.00-20.00 1 1 1 1 1 1 1 T15 Yes No 1 1 1 1 1 1 1 1 20.00-0.00 1 1 1 1 1 1 1 1 Note: K factors are applied to member segment lengths. K-braces without inner supporting members will have the K factor in the out-of-plane direction applied to the overall length. Tower Section Geometry (cont’d) Tower Elevation ft T1 240.00-230.00 T2 230.00-220.00 T3 220.00-200.00 T4 200.00-180.00 T5 180.00-160.00 T6 160.00-150.00 T7 150.00-140.00 T8 140.00-130.00 T9 130.00-120.00 T10 120.00-100.00 T11 100.00-80.00 T12 80.00-60.00 T13 60.00-40.00 T14 40.00-20.00 T15 Truss-Leg K Factors Truss-Legs Used As Leg Members Truss-Legs Used As Inner Members Leg X Z Leg X Z Panels Brace Brace Panels Brace Brace Diagonals Diagonals Diagonals Diagonals 1 0.5 0.85 1 1 1 1 0.5 0.85 1 1 1 1 0.5 0.85 1 0.5 0.85 1 0.5 0.85 1 0.5 0.85 1 0.5 0.85 1 0.5 0.85 1 0.5 0.85 1 0.5 0.85 1 0.5 0.85 1 0.5 0.85 1 0.5 0.85 1 0.5 0.85 1 0.5 0.85 1 0.5 0.85 1 0.5 0.85 1 0.5 0.85 1 0.5 0.85 1 0.5 0.85 1 0.5 0.85 1 0.5 0.85 1 0.5 0.85 1 0.5 0.85 1 0.5 0.85 1 0.5 0.85 1 0.5 0.85 1 0.5 0.85 6 of 26 240-ft S/S Tower - MFP #24112-007 Project Michael F. Plahovinsak, P.E. Date 2012-05, Christopher 18301 State Route 161 W Plain City, OH 43064 Phone: 614-398-6250 FAX: mike@mfpeng.com Tower Elevation ft 20.00-0.00 Page Job tnxTower 12:26:46 10/09/12 Client Designed by St. Charles Tower Mike Truss-Leg K Factors Truss-Legs Used As Leg Members Truss-Legs Used As Inner Members Leg X Z Leg X Z Panels Brace Brace Panels Brace Brace Diagonals Diagonals Diagonals Diagonals Tower Section Geometry (cont’d) Tower Elevation ft T1 240.00-230.00 T2 230.00-220.00 T3 220.00-200.00 T4 200.00-180.00 T5 180.00-160.00 T6 160.00-150.00 T7 150.00-140.00 T8 140.00-130.00 T9 130.00-120.00 T10 120.00-100.00 T11 100.00-80.00 T12 80.00-60.00 T13 60.00-40.00 T14 40.00-20.00 T15 20.00-0.00 Leg Diagonal Top Girt Bottom Girt Net Width Deduct in U Net Width Deduct in U Net Width Deduct in U U 1 Net Width Deduct in 0.00 0.00 1 0.00 0.75 0.00 0.00 1 0.00 0.75 0.00 1 0.00 1 0.00 0.75 0.00 0.00 1 0.00 0.75 0.00 1 0.00 0.00 1 0.00 Mid Girt Long Horizontal Short Horizontal U U 1 Net Width Deduct in 0.00 U 1 Net Width Deduct in 0.00 1 Net Width Deduct in 0.00 0.00 1 0.00 1 0.00 1 0.00 1 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 1 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 1 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 1 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 1 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 1 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 1 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 1 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 1 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 1 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 0.00 0.75 1 Tower Section Geometry (cont’d) Tower Elevation ft T1 240.00-230.00 Leg Connection Type Flange Leg Bolt Size in 1.00 A325SC Diagonal No. 6 Bolt Size in 1.00 A325N Top Girt No. 1 Bolt Size in 0.00 A325N Bottom Girt No. 0 Bolt Size in 0.00 A325N No. 0 Mid Girt Bolt Size in 0.00 A325N Long Horizontal Short Horizontal No. 0 Bolt Size in 0.00 A325N No. 0 Bolt Size in 0.00 A325N No. 0 Project T2 230.00-220.00 T3 220.00-200.00 T4 200.00-180.00 T5 180.00-160.00 T6 160.00-150.00 T7 150.00-140.00 T8 140.00-130.00 T9 130.00-120.00 T10 120.00-100.00 T11 100.00-80.00 T12 80.00-60.00 T13 60.00-40.00 T14 40.00-20.00 T15 20.00-0.00 Flange Flange Flange Flange Flange Flange Flange Flange Flange Flange Flange Flange Flange 12:26:46 10/09/12 Client Designed by St. Charles Tower Leg Bolt Size in 1.00 A325N 1.00 A325N 1.00 A325N 1.25 A325N 1.25 A325N 1.25 A325N 1.25 A325N 1.25 A325N 1.25 A325N 1.25 A325N 1.25 A325N 1.25 A325N 1.25 A325N 1.25 A687 Flange Date 2012-05, Christopher 18301 State Route 161 W Plain City, OH 43064 Phone: 614-398-6250 FAX: mike@mfpeng.com Leg Connection Type 7 of 26 240-ft S/S Tower - MFP #24112-007 Michael F. Plahovinsak, P.E. Tower Elevation ft Page Job tnxTower Diagonal No. 6 6 6 6 6 0 6 0 6 6 6 12 12 6 Bolt Size in 1.00 A325N 1.00 A325N 1.00 A325N 1.25 A325N 1.25 A325N 1.25 A325N 1.25 A325N 1.25 A325N 1.25 A325N 1.25 A325N 1.25 A325N 1.25 A325N 1.25 A325N 1.25 A325N Top Girt No. 1 1 1 1 1 1 1 1 1 1 1 2 2 2 Bolt Size in 0.50 A325N 1.00 A325N 1.00 A325N 1.00 A325N 1.00 A325N 1.00 A325N 1.00 A325N 1.00 A325N 1.00 A325N 1.00 A325N 1.25 A325N 1.25 A325N 1.25 A325N 1.25 A325N Mike Bottom Girt No. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Bolt Size in 0.50 A325N 1.00 A325N 1.00 A325N 1.00 A325N 0.00 A325N 1.00 A325N 0.00 A325N 1.00 A325N 1.00 A325N 1.00 A325N 1.25 A325N 1.25 A325N 1.25 A325N 1.25 A325N No. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Mid Girt Bolt Size in 0.50 A325N 1.00 A325N 1.00 A325N 1.00 A325N 1.00 A325N 1.00 A325N 1.00 A325N 1.00 A325N 1.00 A325N 1.00 A325N 1.25 A325N 1.25 A325N 1.25 A325N 1.25 A325N Long Horizontal Short Horizontal No. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Bolt Size in 0.50 A325N 1.00 A325N 1.00 A325N 1.00 A325N 1.00 A325N 1.00 A325N 1.00 A325N 1.00 A325N 1.00 A325N 1.00 A325N 1.25 A325N 1.25 A325N 1.25 A325N 1.25 A325N No. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Bolt Size in 0.50 A325N 1.00 A325N 1.00 A325N 1.00 A325N 1.00 A325N 1.00 A325N 1.00 A325N 1.00 A325N 1.00 A325N 1.00 A325N 1.25 A325N 1.25 A325N 1.25 A325N 1.25 A325N No. Feed Line/Linear Appurtenances - Entered As Round Or Flat Description VXL7-50 (1-5/8 FOAM) VXL7-50 (1-5/8 FOAM) VXL7-50 (1-5/8 FOAM) Face Allow or Shield Leg C No Component Type Placement Ar (CaAa) ft 230.00 - 0.00 Face Offset in 0.00 Lateral Offset (Frac FW) 0.25 # 9 # Per Row 9 C No Ar (CaAa) 220.00 - 0.00 0.00 -0.25 9 9 C No Ar (CaAa) 210.00 - 0.00 0.00 0 9 9 Clear Width or Perimeter Spacing Diameter in in in 0.52 1.98 0.00 0.52 1.98 0.00 0.52 1.98 0.00 Feed Line/Linear Appurtenances - Entered As Area Description 1'' lighting conduit *** Face Allow or Shield Leg C No Component Type CaAa (In Face) Placement ft 240.00 - 0.00 Total Number 1 No Ice 1/2'' Ice 1'' Ice CAAA Weight 2 plf 2.00 2.92 4.44 ft /ft 0.10 0.20 0.30 Weight plf 0.75 0.75 0.75 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18301 State Route 161 W Plain City, OH 43064 Phone: 614-398-6250 FAX: mike@mfpeng.com 1/4'' 8 of 26 240-ft S/S Tower - MFP #24112-007 Michael F. Plahovinsak, P.E. Description Page Job tnxTower Project Date 2012-05, Christopher 12:26:46 10/09/12 Client Designed by St. Charles Tower Face Allow or Shield Leg C No Component Type CaAa (Out Of Face) Placement Total Number ft 160.00 - 0.00 1 No Ice 1/2'' Ice 1'' Ice Mike CAAA Weight ft2/ft 0.03 0.13 0.23 plf 0.06 0.58 1.70 Feed Line/Linear Appurtenances Section Areas Tower Section T1 Tower Elevation ft 240.00-230.00 T2 230.00-220.00 T3 220.00-200.00 T4 200.00-180.00 T5 180.00-160.00 T6 160.00-150.00 T7 150.00-140.00 T8 140.00-130.00 T9 130.00-120.00 T10 120.00-100.00 T11 100.00-80.00 T12 80.00-60.00 T13 60.00-40.00 T14 40.00-20.00 T15 20.00-0.00 Face AR AF A B C A B C A B C A B C A B C A B C A B C A B C A B C A B C A B C A B C A B C A B C A B C ft2 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ft2 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 CAAA In Face ft2 0.000 0.000 1.000 0.000 0.000 18.820 0.000 0.000 91.100 0.000 0.000 108.920 0.000 0.000 108.920 0.000 0.000 54.460 0.000 0.000 54.460 0.000 0.000 54.460 0.000 0.000 54.460 0.000 0.000 108.920 0.000 0.000 108.920 0.000 0.000 108.920 0.000 0.000 108.920 0.000 0.000 108.920 0.000 0.000 108.920 CAAA Out Face ft2 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.345 0.000 0.000 0.345 0.000 0.000 0.345 0.000 0.000 0.345 0.000 0.000 0.690 0.000 0.000 0.690 0.000 0.000 0.690 0.000 0.000 0.690 0.000 0.000 0.690 0.000 0.000 0.690 Weight K 0.00 0.00 0.02 0.00 0.00 0.09 0.00 0.00 0.38 0.00 0.00 0.45 0.00 0.00 0.45 0.00 0.00 0.22 0.00 0.00 0.22 0.00 0.00 0.22 0.00 0.00 0.22 0.00 0.00 0.45 0.00 0.00 0.45 0.00 0.00 0.45 0.00 0.00 0.45 0.00 0.00 0.45 0.00 0.00 0.45 Page Job tnxTower 9 of 26 240-ft S/S Tower - MFP #24112-007 Michael F. Plahovinsak, P.E. 18301 State Route 161 W Plain City, OH 43064 Phone: 614-398-6250 FAX: mike@mfpeng.com Project Date 2012-05, Christopher 12:26:46 10/09/12 Client Designed by St. Charles Tower Mike Feed Line/Linear Appurtenances Section Areas - With Ice Tower Section T1 Tower Elevation ft 240.00-230.00 T2 230.00-220.00 T3 220.00-200.00 T4 200.00-180.00 T5 180.00-160.00 T6 160.00-150.00 T7 150.00-140.00 T8 140.00-130.00 T9 130.00-120.00 T10 120.00-100.00 T11 100.00-80.00 T12 80.00-60.00 T13 60.00-40.00 T14 40.00-20.00 T15 20.00-0.00 Face or Leg A B C A B C A B C A B C A B C A B C A B C A B C A B C A B C A B C A B C A B C A B C A B C Ice Thickness in 2.434 2.423 2.407 2.383 2.356 2.335 2.319 2.303 2.285 2.256 2.211 2.156 2.085 1.981 1.775 AR AF ft2 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ft2 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 CAAA In Face ft2 0.000 0.000 5.868 0.000 0.000 40.448 0.000 0.000 184.382 0.000 0.000 218.401 0.000 0.000 217.816 0.000 0.000 108.667 0.000 0.000 108.495 0.000 0.000 108.312 0.000 0.000 108.117 0.000 0.000 215.591 0.000 0.000 214.599 0.000 0.000 213.386 0.000 0.000 211.813 0.000 0.000 209.528 0.000 0.000 205.014 CAAA Out Face ft2 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 5.014 0.000 0.000 4.983 0.000 0.000 4.950 0.000 0.000 4.915 0.000 0.000 9.713 0.000 0.000 9.534 0.000 0.000 9.315 0.000 0.000 9.029 0.000 0.000 8.614 0.000 0.000 7.790 Feed Line Center of Pressure Section Elevation CPX CPZ T1 T2 T3 ft 240.00-230.00 230.00-220.00 220.00-200.00 in 0.00 -3.07 0.00 in 0.40 3.88 6.24 CPX Ice in 0.00 -1.68 0.00 CPZ Ice in 0.68 2.47 4.18 Weight K 0.00 0.00 0.13 0.00 0.00 0.76 0.00 0.00 3.40 0.00 0.00 3.99 0.00 0.00 3.95 0.00 0.00 2.04 0.00 0.00 2.03 0.00 0.00 2.01 0.00 0.00 2.00 0.00 0.00 3.95 0.00 0.00 3.87 0.00 0.00 3.77 0.00 0.00 3.65 0.00 0.00 3.48 0.00 0.00 3.16 Page Job tnxTower Michael F. Plahovinsak, P.E. 18301 State Route 161 W Plain City, OH 43064 Phone: 614-398-6250 FAX: mike@mfpeng.com Project Date 2012-05, Christopher Client Elevation CPX CPZ T4 T5 T6 T7 T8 T9 T10 T11 T12 T13 T14 T15 ft 200.00-180.00 180.00-160.00 160.00-150.00 150.00-140.00 140.00-130.00 130.00-120.00 120.00-100.00 100.00-80.00 80.00-60.00 60.00-40.00 40.00-20.00 20.00-0.00 in 0.00 0.00 -0.10 -0.11 -0.12 -0.12 -0.13 -0.14 -0.15 -0.17 -0.18 -0.19 in 7.67 8.95 9.80 10.05 10.86 10.93 12.31 13.10 14.16 15.68 16.85 18.00 CPX Ice in 0.00 0.00 -0.69 -0.70 -0.77 -0.77 -0.86 -0.92 -0.98 -1.04 -1.08 -1.07 CPZ Ice in 5.23 6.11 6.94 7.08 7.76 7.80 8.83 9.57 10.40 11.40 12.35 13.38 Shielding Factor Ka Feed Line Record No. Description 1 1" lighting conduit T2 1 1" lighting conduit T2 2 VXL7-50 (1-5/8 FOAM) T3 1 1" lighting conduit T3 2 VXL7-50 (1-5/8 FOAM) T3 3 VXL7-50 (1-5/8 FOAM) T3 4 VXL7-50 (1-5/8 FOAM) T4 1 1" lighting conduit T4 2 VXL7-50 (1-5/8 FOAM) T4 3 VXL7-50 (1-5/8 FOAM) T4 4 VXL7-50 (1-5/8 FOAM) T5 1 1" lighting conduit T5 2 VXL7-50 (1-5/8 FOAM) T5 3 VXL7-50 (1-5/8 FOAM) T5 4 VXL7-50 (1-5/8 FOAM) T6 1 1" lighting conduit T6 2 VXL7-50 (1-5/8 FOAM) T6 3 VXL7-50 (1-5/8 FOAM) T6 4 VXL7-50 (1-5/8 FOAM) 12:26:46 10/09/12 Designed by St. Charles Tower Section Tower Section T1 10 of 26 240-ft S/S Tower - MFP #24112-007 Feed Line Segment Elev. 230.00 240.00 220.00 230.00 220.00 230.00 200.00 220.00 200.00 220.00 200.00 220.00 200.00 210.00 180.00 200.00 180.00 200.00 180.00 200.00 180.00 200.00 160.00 180.00 160.00 180.00 160.00 180.00 160.00 180.00 150.00 160.00 150.00 160.00 150.00 160.00 150.00 160.00 Ka No Ice 1.0000 Ka Ice 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 Mike 18301 State Route 161 W Plain City, OH 43064 Phone: 614-398-6250 FAX: mike@mfpeng.com Feed Line Record No. 11 of 26 240-ft S/S Tower - MFP #24112-007 Michael F. Plahovinsak, P.E. Tower Section T7 Page Job tnxTower Project Date 2012-05, Christopher Client Designed by St. Charles Tower Description 1 1" lighting conduit T7 2 VXL7-50 (1-5/8 FOAM) T7 3 VXL7-50 (1-5/8 FOAM) T7 4 VXL7-50 (1-5/8 FOAM) T8 1 1" lighting conduit T8 2 VXL7-50 (1-5/8 FOAM) T8 3 VXL7-50 (1-5/8 FOAM) T8 4 VXL7-50 (1-5/8 FOAM) T9 1 1" lighting conduit T9 2 VXL7-50 (1-5/8 FOAM) T9 3 VXL7-50 (1-5/8 FOAM) T9 4 VXL7-50 (1-5/8 FOAM) T10 1 1" lighting conduit T10 2 VXL7-50 (1-5/8 FOAM) T10 3 VXL7-50 (1-5/8 FOAM) T10 4 VXL7-50 (1-5/8 FOAM) T11 T11 T11 T11 T12 T12 T12 T12 T13 T13 T13 T13 T14 T14 T14 T14 T15 T15 T15 T15 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1" lighting conduit VXL7-50 (1-5/8 FOAM) VXL7-50 (1-5/8 FOAM) VXL7-50 (1-5/8 FOAM) 1" lighting conduit VXL7-50 (1-5/8 FOAM) VXL7-50 (1-5/8 FOAM) VXL7-50 (1-5/8 FOAM) 1" lighting conduit VXL7-50 (1-5/8 FOAM) VXL7-50 (1-5/8 FOAM) VXL7-50 (1-5/8 FOAM) 1" lighting conduit VXL7-50 (1-5/8 FOAM) VXL7-50 (1-5/8 FOAM) VXL7-50 (1-5/8 FOAM) 1" lighting conduit VXL7-50 (1-5/8 FOAM) VXL7-50 (1-5/8 FOAM) VXL7-50 (1-5/8 FOAM) 12:26:46 10/09/12 Feed Line Segment Elev. 140.00 150.00 140.00 150.00 140.00 150.00 140.00 150.00 130.00 140.00 130.00 140.00 130.00 140.00 130.00 140.00 120.00 130.00 120.00 130.00 120.00 130.00 120.00 130.00 100.00 120.00 100.00 120.00 100.00 120.00 100.00 120.00 80.00 - 100.00 80.00 - 100.00 80.00 - 100.00 80.00 - 100.00 60.00 - 80.00 60.00 - 80.00 60.00 - 80.00 60.00 - 80.00 40.00 - 60.00 40.00 - 60.00 40.00 - 60.00 40.00 - 60.00 20.00 - 40.00 20.00 - 40.00 20.00 - 40.00 20.00 - 40.00 0.00 - 20.00 0.00 - 20.00 0.00 - 20.00 0.00 - 20.00 Ka No Ice 1.0000 Ka Ice 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 Discrete Tower Loads Mike 12 of 26 240-ft S/S Tower - MFP #24112-007 Michael F. Plahovinsak, P.E. 18301 State Route 161 W Plain City, OH 43064 Phone: 614-398-6250 FAX: mike@mfpeng.com Description Page Job tnxTower Face or Leg Project Date 2012-05, Christopher 12:26:46 10/09/12 Client Designed by St. Charles Tower Offset Type Flash Beacon Lighting C From Leg (3) 72''x12''x3'' panels A From Leg (3) 72''x12''x3'' panels B From Leg (3) 72''x12''x3'' panels C From Leg (3) TMA A From Leg (3) TMA B From Leg (3) TMA C From Leg PiROD 12' Universal T-Frame Sector Mount A From Leg PiROD 12' Universal T-Frame Sector Mount B From Leg PiROD 12' Universal T-Frame Sector Mount C From Leg (3) 72''x12''x3'' panels A From Leg (3) 72''x12''x3'' panels B From Leg (3) 72''x12''x3'' panels C From Leg (3) TMA A From Leg (3) TMA B From Leg (3) TMA C From Leg PiROD 12' Universal T-Frame Sector Mount A From Leg PiROD 12' Universal T-Frame Sector Mount B From Leg PiROD 12' Universal T-Frame Sector Mount C From Leg Offsets: Horz Lateral Vert ft ft ft 0.00 0 1 4.00 0 0 4.00 0 0 4.00 0 0 3.00 0 0 3.00 0 0 3.00 0 0 3.00 0 0 3.00 0 0 3.00 0 0 4.00 0 0 4.00 0 0 4.00 0 0 3.00 0 0 3.00 0 0 3.00 0 0 3.00 0 0 3.00 0 0 3.00 0 0 Mike Azimuth Adjustment Placement CAAA Front CAAA Side Weight ° ft ft2 ft2 K 0.000 240.00 0.000 230.00 0.000 230.00 0.000 230.00 0.000 230.00 0.000 230.00 0.000 230.00 0.000 230.00 0.000 230.00 0.000 230.00 0.000 220.00 0.000 220.00 0.000 220.00 0.000 220.00 0.000 220.00 0.000 220.00 0.000 220.00 0.000 220.00 0.000 220.00 2.70 3.10 3.50 8.40 8.95 9.51 8.40 8.95 9.51 8.40 8.95 9.51 0.67 0.79 0.91 0.67 0.79 0.91 0.67 0.79 0.91 13.60 18.40 23.20 13.60 18.40 23.20 13.60 18.40 23.20 8.40 8.95 9.51 8.40 8.95 9.51 8.40 8.95 9.51 0.67 0.79 0.91 0.67 0.79 0.91 0.67 0.79 0.91 13.60 18.40 23.20 13.60 18.40 23.20 13.60 18.40 23.20 2.70 3.10 3.50 2.95 3.38 3.82 2.95 3.38 3.82 2.95 3.38 3.82 0.31 0.39 0.47 0.31 0.39 0.47 0.31 0.39 0.47 13.60 18.40 23.20 13.60 18.40 23.20 13.60 18.40 23.20 2.95 3.38 3.82 2.95 3.38 3.82 2.95 3.38 3.82 0.31 0.39 0.47 0.31 0.39 0.47 0.31 0.39 0.47 13.60 18.40 23.20 13.60 18.40 23.20 13.60 18.40 23.20 0.05 0.07 0.09 0.03 0.07 0.11 0.03 0.07 0.11 0.03 0.07 0.11 0.01 0.02 0.03 0.01 0.02 0.03 0.01 0.02 0.03 0.47 0.60 0.73 0.47 0.60 0.73 0.47 0.60 0.73 0.03 0.07 0.11 0.03 0.07 0.11 0.03 0.07 0.11 0.01 0.02 0.03 0.01 0.02 0.03 0.01 0.02 0.03 0.47 0.60 0.73 0.47 0.60 0.73 0.47 0.60 0.73 No Ice 1/2'' Ice 1'' Ice No Ice 1/2'' Ice 1'' Ice No Ice 1/2'' Ice 1'' Ice No Ice 1/2'' Ice 1'' Ice No Ice 1/2'' Ice 1'' Ice No Ice 1/2'' Ice 1'' Ice No Ice 1/2'' Ice 1'' Ice No Ice 1/2'' Ice 1'' Ice No Ice 1/2'' Ice 1'' Ice No Ice 1/2'' Ice 1'' Ice No Ice 1/2'' Ice 1'' Ice No Ice 1/2'' Ice 1'' Ice No Ice 1/2'' Ice 1'' Ice No Ice 1/2'' Ice 1'' Ice No Ice 1/2'' Ice 1'' Ice No Ice 1/2'' Ice 1'' Ice No Ice 1/2'' Ice 1'' Ice No Ice 1/2'' Ice 1'' Ice No Ice 1/2'' Ice 1'' Ice 13 of 26 240-ft S/S Tower - MFP #24112-007 Michael F. Plahovinsak, P.E. 18301 State Route 161 W Plain City, OH 43064 Phone: 614-398-6250 FAX: mike@mfpeng.com Description Page Job tnxTower Face or Leg Project Date 2012-05, Christopher 12:26:46 10/09/12 Client Designed by St. Charles Tower Offset Type (3) 72''x12''x3'' panels A From Leg (3) 72''x12''x3'' panels B From Leg (3) 72''x12''x3'' panels C From Leg (3) TMA A From Leg (3) TMA B From Leg (3) TMA C From Leg PiROD 12' Universal T-Frame Sector Mount A From Leg PiROD 12' Universal T-Frame Sector Mount B From Leg PiROD 12' Universal T-Frame Sector Mount C From Leg *** 12 ft x 2'' dia whip C From Face 3' Side Arm Mount C None Mike Offsets: Horz Lateral Vert ft ft ft 4.00 0 0 4.00 0 0 4.00 0 0 3.00 0 0 3.00 0 0 3.00 0 0 3.00 0 0 3.00 0 0 3.00 0 0 Azimuth Adjustment Placement CAAA Front CAAA Side Weight ° ft ft2 ft2 K 0.000 210.00 0.000 210.00 0.000 210.00 0.000 210.00 0.000 210.00 0.000 210.00 0.000 210.00 0.000 210.00 0.000 210.00 No Ice 1/2'' Ice 1'' Ice No Ice 1/2'' Ice 1'' Ice No Ice 1/2'' Ice 1'' Ice No Ice 1/2'' Ice 1'' Ice No Ice 1/2'' Ice 1'' Ice No Ice 1/2'' Ice 1'' Ice No Ice 1/2'' Ice 1'' Ice No Ice 1/2'' Ice 1'' Ice No Ice 1/2'' Ice 1'' Ice 8.40 8.95 9.51 8.40 8.95 9.51 8.40 8.95 9.51 0.67 0.79 0.91 0.67 0.79 0.91 0.67 0.79 0.91 13.60 18.40 23.20 13.60 18.40 23.20 13.60 18.40 23.20 2.95 3.38 3.82 2.95 3.38 3.82 2.95 3.38 3.82 0.31 0.39 0.47 0.31 0.39 0.47 0.31 0.39 0.47 13.60 18.40 23.20 13.60 18.40 23.20 13.60 18.40 23.20 0.03 0.07 0.11 0.03 0.07 0.11 0.03 0.07 0.11 0.01 0.02 0.03 0.01 0.02 0.03 0.01 0.02 0.03 0.47 0.60 0.73 0.47 0.60 0.73 0.47 0.60 0.73 1.00 0 0 0.000 160.00 0.000 160.00 No Ice 1/2'' Ice 1'' Ice No Ice 1/2'' Ice 1'' Ice 2.40 3.63 4.87 0.76 0.96 1.16 2.40 3.63 4.87 0.76 0.96 1.16 0.02 0.04 0.07 0.03 0.04 0.05 Truss-Leg Properties Section Designation Pirod 105217 (12x1.5) Pirod 105217 (12x1.5) Pirod 105217 (12x1.5) Pirod 105218 (12x1.75) Pirod 105218 (12x1.75) Area Area Ice Self Weight Ice Weight Equiv. Diameter in2 2130.75 in2 7184.53 K 0.62 K 2.61 in 7.40 Equiv. Diameter Ice in 24.95 Leg Area 2130.75 7175.19 0.62 2.61 7.40 24.91 5.30 2130.75 7160.46 0.62 2.60 7.40 24.86 5.30 2263.47 7211.28 0.75 2.63 7.86 25.04 7.22 2263.47 7187.98 0.75 2.62 7.86 24.96 7.22 in2 5.30 tnxTower Michael F. Plahovinsak, P.E. 18301 State Route 161 W Plain City, OH 43064 Phone: 614-398-6250 FAX: mike@mfpeng.com Section Designation Pirod 105219 (12x2) Pirod 105219 (12x2) Pirod 105219 (12x2) Pirod 105219 (12x2) Pirod 105219 (12x2) Pirod 105220 (12x2.25) Pirod 105220 (12x2.25) Pirod 112743 Pirod 112743 Pirod 112738 (18x2.5) Page Job Project Date 2012-05, Christopher 12:26:46 10/09/12 Client Designed by St. Charles Tower Self Weight Ice Weight Equiv. Diameter Mike Area Area Ice in2 2441.87 2441.87 2441.87 2441.87 2441.87 2578.80 in2 7240.83 7227.11 7212.51 7196.91 7171.25 7203.63 K 0.94 0.94 0.94 0.94 0.94 1.12 K 2.65 2.64 2.63 2.62 2.61 2.62 in 8.48 8.48 8.48 8.48 8.48 8.95 Equiv. Diameter Ice in 25.14 25.09 25.04 24.99 24.90 25.01 2578.80 7155.12 1.12 2.59 8.95 24.84 11.93 3466.52 3466.52 3466.52 9217.97 9140.15 8985.65 1.69 1.69 1.69 4.56 4.48 4.34 12.04 12.04 12.04 32.01 31.74 31.20 14.73 14.73 14.73 Load Combinations Comb. No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 14 of 26 240-ft S/S Tower - MFP #24112-007 Description Dead Only 1.2 Dead+1.6 Wind 0 deg - No Ice 0.9 Dead+1.6 Wind 0 deg - No Ice 1.2 Dead+1.6 Wind 30 deg - No Ice 0.9 Dead+1.6 Wind 30 deg - No Ice 1.2 Dead+1.6 Wind 60 deg - No Ice 0.9 Dead+1.6 Wind 60 deg - No Ice 1.2 Dead+1.6 Wind 90 deg - No Ice 0.9 Dead+1.6 Wind 90 deg - No Ice 1.2 Dead+1.6 Wind 120 deg - No Ice 0.9 Dead+1.6 Wind 120 deg - No Ice 1.2 Dead+1.6 Wind 150 deg - No Ice 0.9 Dead+1.6 Wind 150 deg - No Ice 1.2 Dead+1.6 Wind 180 deg - No Ice 0.9 Dead+1.6 Wind 180 deg - No Ice 1.2 Dead+1.6 Wind 210 deg - No Ice 0.9 Dead+1.6 Wind 210 deg - No Ice 1.2 Dead+1.6 Wind 240 deg - No Ice 0.9 Dead+1.6 Wind 240 deg - No Ice 1.2 Dead+1.6 Wind 270 deg - No Ice 0.9 Dead+1.6 Wind 270 deg - No Ice 1.2 Dead+1.6 Wind 300 deg - No Ice 0.9 Dead+1.6 Wind 300 deg - No Ice 1.2 Dead+1.6 Wind 330 deg - No Ice 0.9 Dead+1.6 Wind 330 deg - No Ice 1.2 Dead+1.0 Ice 1.2 Dead+1.0 Wind 0 deg+1.0 Ice 1.2 Dead+1.0 Wind 30 deg+1.0 Ice 1.2 Dead+1.0 Wind 60 deg+1.0 Ice 1.2 Dead+1.0 Wind 90 deg+1.0 Ice 1.2 Dead+1.0 Wind 120 deg+1.0 Ice 1.2 Dead+1.0 Wind 150 deg+1.0 Ice 1.2 Dead+1.0 Wind 180 deg+1.0 Ice 1.2 Dead+1.0 Wind 210 deg+1.0 Ice 1.2 Dead+1.0 Wind 240 deg+1.0 Ice 1.2 Dead+1.0 Wind 270 deg+1.0 Ice 1.2 Dead+1.0 Wind 300 deg+1.0 Ice 1.2 Dead+1.0 Wind 330 deg+1.0 Ice Dead+Wind 0 deg - Service Leg Area in2 9.42 9.42 9.42 9.42 9.42 11.93 15 of 26 240-ft S/S Tower - MFP #24112-007 Michael F. Plahovinsak, P.E. 18301 State Route 161 W Plain City, OH 43064 Phone: 614-398-6250 FAX: mike@mfpeng.com Comb. No. 40 41 42 43 44 45 46 47 48 49 50 Page Job tnxTower Project Date 2012-05, Christopher 12:26:46 10/09/12 Client Designed by St. Charles Tower Mike Description Dead+Wind 30 deg - Service Dead+Wind 60 deg - Service Dead+Wind 90 deg - Service Dead+Wind 120 deg - Service Dead+Wind 150 deg - Service Dead+Wind 180 deg - Service Dead+Wind 210 deg - Service Dead+Wind 240 deg - Service Dead+Wind 270 deg - Service Dead+Wind 300 deg - Service Dead+Wind 330 deg - Service Maximum Member Forces Section No. Elevation ft Component Type Condition T1 240 - 230 Leg Diagonal Top Girt T2 230 - 220 Leg Diagonal Secondary Horizontal T3 220 - 200 Leg Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Gov. Load Comb. 7 35 3 4 6 24 22 10 33 31 35 35 3 29 26 31 26 31 15 35 6 4 6 12 9 10 33 31 34 31 2 Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy 7 26 31 26 31 15 18 14 12 22 Axial K 0.33 -2.22 -0.70 -0.41 -0.15 0.27 0.54 -0.62 -0.24 -0.05 0.05 -0.00 0.03 -0.04 -0.02 -0.03 0.06 -0.00 3.92 -8.27 2.96 -0.46 -1.50 -1.01 2.66 -2.84 0.44 -0.14 0.05 -0.00 0.45 Major Axis Moment kip-ft 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 Minor Axis Moment kip-ft 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1 0 0 0 0 0 0 0 -0.39 0.12 0.14 0.09 -0.00 27.38 -34.68 25.80 -4.24 -1.24 0 0 0 0 0 0 1 -1 0 0 0 0 0 0 0 0 0 0 -2 0 18301 State Route 161 W Plain City, OH 43064 Phone: 614-398-6250 FAX: mike@mfpeng.com Elevation ft 200 - 180 180 - 160 Component Type Leg Leg Diagonal T6 160 - 150 Leg Diagonal T7 150 - 140 Date 2012-05, Christopher 12:26:46 10/09/12 Designed by St. Charles Tower Diagonal T5 Project Client Diagonal T4 16 of 26 240-ft S/S Tower - MFP #24112-007 Michael F. Plahovinsak, P.E. Section No. Page Job tnxTower Leg Diagonal Top Girt Condition Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Gov. Load Comb. 16 8 8 33 31 33 31 15 18 14 12 6 16 8 8 33 31 33 31 15 18 14 12 6 12 8 8 33 31 33 35 15 18 14 12 29 12 8 8 33 31 33 35 15 18 18 12 29 12 8 8 33 32 33 32 14 19 26 31 26 31 Axial K 1.15 6.99 -7.08 1.50 0.12 0.08 -0.01 60.67 -71.59 59.24 -5.68 0.17 -0.18 7.79 -7.88 1.60 0.12 0.09 -0.01 93.95 -108.37 92.25 -7.17 0.29 0.39 8.44 -8.53 1.75 0.23 0.10 0.01 110.29 -126.59 108.83 -7.35 -0.34 -0.64 9.41 -9.70 1.68 0.13 0.12 0.01 126.94 -145.79 -145.16 -9.09 0.36 0.74 9.38 -9.61 1.64 -1.00 0.13 -0.01 2.06 -1.82 0.75 0.92 -0.20 0.01 Mike Major Axis Moment kip-ft 0 0 0 0 0 0 0 -1 2 -2 0 -2 0 0 0 0 0 0 0 -2 3 -3 0 -3 0 0 0 0 0 0 0 -3 3 -3 0 -2 0 0 0 0 0 0 0 -3 2 3 0 -2 0 0 0 0 0 0 0 0 0 -1 0 0 0 Minor Axis Moment kip-ft 0 0 0 0 0 0 0 0 0 0 -2 0 2 0 0 0 0 0 0 0 0 0 -4 0 -4 0 0 0 0 0 0 0 0 0 -4 0 -4 0 0 0 0 0 0 0 0 0 -6 0 -6 0 0 0 0 0 0 0 0 0 0 0 0 Page Job tnxTower Michael F. Plahovinsak, P.E. 18301 State Route 161 W Plain City, OH 43064 Phone: 614-398-6250 FAX: mike@mfpeng.com Project Date 2012-05, Christopher Designed by St. Charles Tower Elevation ft Component Type Condition T8 140 - 130 Leg Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Diagonal 130 - 120 Leg Diagonal Top Girt T10 120 - 100 Leg Diagonal T11 100 - 80 Leg Diagonal T12 80 - 60 12:26:46 10/09/12 Client Section No. T9 17 of 26 240-ft S/S Tower - MFP #24112-007 Leg Diagonal Gov. Load Comb. 15 18 18 12 2 12 8 8 33 36 33 31 15 18 18 16 2 12 8 8 33 32 33 32 14 19 26 31 26 31 15 18 18 16 2 12 8 8 33 31 33 31 15 18 14 12 6 12 8 8 33 31 33 31 15 18 14 12 29 12 8 Axial K 143.54 -164.79 -164.79 -9.49 -0.35 -0.70 10.44 -10.68 1.86 1.50 0.16 -0.01 160.18 -184.12 -183.50 -11.17 0.32 0.55 10.56 -10.94 1.55 -1.22 0.16 -0.01 2.54 -2.23 0.97 1.18 0.25 0.01 194.32 -223.77 -204.43 -11.81 -0.24 -0.28 11.89 -12.12 1.97 0.30 0.18 -0.01 228.05 -263.41 224.36 -15.83 0.38 0.47 12.64 -12.81 2.20 0.60 0.20 -0.01 262.11 -304.47 257.76 -18.72 0.65 1.12 13.79 Mike Major Axis Moment kip-ft -2 4 4 0 4 0 0 0 0 0 0 0 -3 2 4 0 4 0 0 0 0 0 0 0 0 0 -1 0 0 0 -3 3 3 0 3 0 0 0 0 0 0 0 -3 5 -5 0 -5 0 0 0 0 0 0 0 -3 7 -8 -1 -4 -1 0 Minor Axis Moment kip-ft 0 0 0 -6 0 -6 0 0 0 0 0 0 0 0 0 4 0 -4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 0 -4 0 0 0 0 0 0 0 0 0 -6 0 -6 0 0 0 0 0 0 0 0 0 -10 0 -10 0 Project T13 60 - 40 40 - 20 20 - 0 Designed by St. Charles Tower Component Type Leg Leg Diagonal T15 12:26:46 10/09/12 Client Diagonal T14 Date 2012-05, Christopher 18301 State Route 161 W Plain City, OH 43064 Phone: 614-398-6250 FAX: mike@mfpeng.com Elevation ft 18 of 26 240-ft S/S Tower - MFP #24112-007 Michael F. Plahovinsak, P.E. Section No. Page Job tnxTower Leg Diagonal Condition Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Gov. Load Comb. 8 33 32 33 31 15 18 18 12 29 12 9 10 33 31 33 36 15 18 18 12 29 12 10 8 33 32 33 32 15 18 14 12 6 12 9 10 34 35 34 35 Axial K -14.32 2.64 -1.47 0.25 -0.01 284.53 -331.26 -331.26 -19.00 -0.44 -0.47 17.01 -18.69 1.93 -6.57 -0.35 -0.02 319.75 -376.12 -373.98 -25.57 0.52 0.82 17.92 -17.55 3.71 -1.73 -0.37 0.02 347.37 -410.04 341.70 -25.96 -0.76 -1.11 18.29 -20.75 1.53 1.66 -0.37 -0.02 Mike Major Axis Moment kip-ft 0 1 1 1 0 -7 10 10 -1 -4 -1 0 0 -1 -1 -1 0 -9 8 10 -1 -6 -1 0 0 -1 -1 -1 0 -10 0 -10 -1 -10 -1 0 0 -1 -1 -1 0 Minor Axis Moment kip-ft 0 0 0 0 0 0 0 0 -10 0 -10 0 0 0 0 0 0 0 0 0 -17 0 -17 0 0 0 0 0 0 0 0 0 -17 0 -17 0 0 0 0 0 0 Maximum Tower Deflections - Service Wind Section No. T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 Elevation ft 240 - 230 230 - 220 220 - 200 200 - 180 180 - 160 160 - 150 150 - 140 140 - 130 130 - 120 120 - 100 Horz. Deflection in 5.44 5.06 4.68 3.92 3.19 2.53 2.23 1.94 1.68 1.43 Gov. Load Comb. 47 47 47 47 47 47 47 47 47 47 Tilt Twist ° 0.180 0.180 0.179 0.171 0.159 0.141 0.133 0.125 0.116 0.106 ° 0.015 0.014 0.014 0.013 0.011 0.009 0.008 0.008 0.007 0.006 Project T11 T12 T13 T14 T15 ft 100 - 80 80 - 60 60 - 40 40 - 20 20 - 0 Date 2012-05, Christopher 18301 State Route 161 W Plain City, OH 43064 Phone: 614-398-6250 FAX: mike@mfpeng.com Elevation 19 of 26 240-ft S/S Tower - MFP #24112-007 Michael F. Plahovinsak, P.E. Section No. Page Job tnxTower 12:26:46 10/09/12 Client Designed by St. Charles Tower Horz. Deflection in 1.00 0.64 0.37 0.17 0.05 Gov. Load Comb. 47 47 47 47 47 Mike Tilt Twist ° 0.085 0.068 0.049 0.033 0.017 ° 0.005 0.003 0.002 0.001 0.001 Critical Deflections and Radius of Curvature - Service Wind Elevation Appurtenance ft 240.00 230.00 220.00 210.00 160.00 Flash Beacon Lighting (3) 72''x12''x3'' panels (3) 72''x12''x3'' panels (3) 72''x12''x3'' panels 12 ft x 2'' dia whip Gov. Load Comb. 47 47 47 47 47 Deflection Tilt Twist in 5.44 5.06 4.68 4.30 2.53 ° 0.180 0.180 0.179 0.176 0.141 ° 0.015 0.014 0.014 0.013 0.009 Radius of Curvature ft 269690 160552 Inf 225257 46979 Maximum Tower Deflections - Design Wind Section No. T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 T13 T14 T15 Elevation ft 240 - 230 230 - 220 220 - 200 200 - 180 180 - 160 160 - 150 150 - 140 140 - 130 130 - 120 120 - 100 100 - 80 80 - 60 60 - 40 40 - 20 20 - 0 Horz. Deflection in 19.52 18.17 16.80 14.06 11.46 9.07 7.99 6.97 6.03 5.14 3.60 2.31 1.32 0.62 0.17 Gov. Load Comb. 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 Tilt Twist ° 0.645 0.645 0.642 0.615 0.570 0.507 0.479 0.448 0.415 0.380 0.306 0.243 0.176 0.119 0.060 ° 0.053 0.052 0.050 0.046 0.040 0.033 0.030 0.027 0.025 0.023 0.018 0.012 0.008 0.005 0.002 Critical Deflections and Radius of Curvature - Design Wind Elevation Appurtenance ft 240.00 230.00 220.00 210.00 160.00 Flash Beacon Lighting (3) 72''x12''x3'' panels (3) 72''x12''x3'' panels (3) 72''x12''x3'' panels 12 ft x 2'' dia whip Gov. Load Comb. 18 18 18 18 18 Deflection Tilt Twist in 19.52 18.17 16.80 15.42 9.07 ° 0.645 0.645 0.642 0.632 0.507 ° 0.053 0.052 0.050 0.048 0.033 Radius of Curvature ft 75110 44755 367399 63460 13097 Page Job tnxTower 20 of 26 240-ft S/S Tower - MFP #24112-007 Project Michael F. Plahovinsak, P.E. Date 2012-05, Christopher 18301 State Route 161 W Plain City, OH 43064 Phone: 614-398-6250 FAX: mike@mfpeng.com 12:26:46 10/09/12 Client Designed by St. Charles Tower Mike Compression Checks Leg Design Data (Compression) Section No. Elevation Size ft 1 L Lu ft ft T1 240 - 230 Pirod 105217 (12x1.5) 10.02 10.02 T2 230 - 220 Pirod 105217 (12x1.5) 10.02 5.34 T3 220 - 200 Pirod 105217 (12x1.5) 20.03 10.02 T4 200 - 180 Pirod 105218 (12x1.75) 20.03 10.02 T5 180 - 160 Pirod 105218 (12x1.75) 20.03 10.02 T6 160 - 150 Pirod 105219 (12x2) 10.02 10.02 T7 150 - 140 Pirod 105219 (12x2) 10.02 10.02 T8 140 - 130 Pirod 105219 (12x2) 10.02 10.02 T9 130 - 120 Pirod 105219 (12x2) 10.02 10.02 T10 120 - 100 Pirod 105219 (12x2) 20.03 10.02 T11 100 - 80 Pirod 105220 (12x2.25) 20.03 10.02 T12 80 - 60 Pirod 105220 (12x2.25) 20.03 10.02 T13 60 - 40 Pirod 112743 20.03 20.03 T14 40 - 20 Pirod 112743 20.03 20.03 T15 20 - 0 Pirod 112738 (18x2.5) 20.03 20.03 Pu Kl/r A Pn K 5.30 -2.22 K 214.86 5.30 -8.27 214.86 0.038 1 5.30 -34.68 214.86 0.161 1 7.22 -71.59 300.68 0.238 1 7.22 -108.37 300.68 0.360 1 9.42 -126.59 399.87 0.317 1 9.42 -145.79 399.87 0.365 1 9.42 -164.79 399.87 0.412 1 9.42 -184.12 399.87 0.460 1 9.42 -223.77 399.87 0.560 1 11.93 -263.41 512.38 0.514 1 11.93 -304.47 512.38 0.594 1 14.73 -331.26 613.14 0.540 1 14.73 -376.12 613.14 0.613 1 14.73 -410.04 613.14 0.669 1 in 37.8 K=1.00 37.8 K=1.00 37.8 K=1.00 32.4 K=1.00 32.4 K=1.00 28.4 K=1.00 28.4 K=1.00 28.4 K=1.00 28.4 K=1.00 28.4 K=1.00 25.2 K=1.00 25.2 K=1.00 32.6 K=1.00 32.6 K=1.00 32.6 K=1.00 Pu Ratio Pu Pn 0.010 1 2 / Pn controls Truss-Leg Diagonal Data Section No. T1 Elevation ft 240 - 230 Diagonal Size 0.5 Ld ft 1.47 T2 230 - 220 0.5 1.47 120.0 Pn K 238.57 A in2 0.20 Vu K 0.27 Vn K 3.34 Stress Ratio 0.081 120.0 238.57 0.20 1.50 3.34 0.448 Kl/r Page Job tnxTower 21 of 26 240-ft S/S Tower - MFP #24112-007 Project Michael F. Plahovinsak, P.E. Date 2012-05, Christopher 18301 State Route 161 W Plain City, OH 43064 Phone: 614-398-6250 FAX: mike@mfpeng.com 12:26:46 10/09/12 Client Designed by St. Charles Tower Mike Section No. Elevation ft Diagonal Size Ld ft Kl/r Pn K A in2 Vu K Vn K Stress Ratio T3 220 - 200 0.5 1.47 120.0 238.57 0.20 0.27 3.34 0.081 T4 200 - 180 0.5 1.46 119.0 324.71 0.20 0.20 3.38 0.059 T5 180 - 160 0.5 1.46 119.0 324.71 0.20 0.41 3.38 0.120 T6 160 - 150 0.625 1.45 94.4 424.12 0.31 0.64 6.96 0.092 T7 150 - 140 0.625 1.45 94.4 424.12 0.31 0.74 6.96 0.106 T8 140 - 130 0.625 1.45 94.4 424.12 0.31 0.70 6.96 0.101 T9 130 - 120 0.625 1.45 94.4 424.12 0.31 0.56 6.96 0.080 T10 120 - 100 0.625 1.45 94.4 424.12 0.31 0.28 6.96 0.041 T11 100 - 80 0.625 1.43 93.6 536.77 0.31 0.50 7.01 0.071 T12 80 - 60 0.625 1.43 93.6 536.77 0.31 1.12 7.01 0.160 T13 60 - 40 0.75 1.73 93.9 662.68 0.44 0.50 14.36 0.035 T14 40 - 20 0.75 1.73 93.9 662.68 0.44 0.83 14.36 0.058 T15 20 - 0 0.75 1.73 93.9 662.68 0.44 1.12 14.36 0.078 Diagonal Design Data (Compression) Section No. Elevation Size ft L Lu ft ft T1 240 - 230 L 2.5 x 2.5 x 3/16 11.93 5.32 T2 230 - 220 L 2.5 x 2.5 x 3/16 12.50 5.65 T3 220 - 200 L3x3x3/16 13.80 6.35 T4 200 - 180 L3x3x3/16 15.24 7.10 T5 180 - 160 L3x3x3/16 16.80 7.86 T6 160 - 150 L 3 x 3 x 5/16 17.62 8.28 T7 150 - 140 L 3 x 3 x 5/16 18.45 8.70 T8 140 - 130 L3 1/2x3 1/2x5/16 19.30 9.13 T9 130 - 120 L3 1/2x3 1/2x5/16 20.16 9.56 Kl/r A Pn K 0.90 -0.62 K 12.18 0.90 -2.84 10.87 0.262 1 1.09 -7.08 14.87 0.476 1 1.09 -7.88 12.04 0.655 1 1.09 -8.53 9.83 0.867 1 1.78 -9.70 14.15 0.686 1 1.78 -9.61 12.81 0.750 1 2.09 -10.68 18.74 0.570 1 2.09 -10.94 17.07 0.641 1 in 129.0 K=1.00 136.9 K=1.00 127.8 K=1.00 143.0 K=1.00 158.3 K=1.00 168.6 K=1.00 177.2 K=1.00 158.7 K=1.00 166.3 K=1.00 Pu Ratio Pu Pn 0.051 1 2 Project Designed by St. Charles Tower Size L Lu ft ft T10 120 - 100 L3 1/2x3 1/2x5/16 21.92 10.45 T11 100 - 80 L 4 x 4 x 1/4 23.71 11.35 T12 80 - 60 L4x4x3/8 24.62 11.81 T13 60 - 40 2L 3.5 x 3.5 x 5/16 (1) 32.02 15.31 T14 40 - 20 2L 3.5 x 3.5 x 5/16 (1) 33.61 16.11 T15 20 - 0 2L 3.5 x 3.5 x 5/16 (1) 35.23 16.93 Pu 12:26:46 10/09/12 Client ft 1 Date 2012-05, Christopher 18301 State Route 161 W Plain City, OH 43064 Phone: 614-398-6250 FAX: mike@mfpeng.com Elevation 22 of 26 240-ft S/S Tower - MFP #24112-007 Michael F. Plahovinsak, P.E. Section No. Page Job tnxTower Kl/r 181.7 K=1.00 171.4 K=1.00 179.9 K=1.00 157.9 K=0.93 164.7 K=0.92 171.6 K=0.91 Mike A Pu Pn in2 K K Ratio Pu Pn 2.09 -12.12 14.30 0.847 1 1.94 -12.81 14.93 0.858 1 2.86 -14.32 19.97 0.717 1 4.18 -18.69 37.88 0.493 1 4.18 -17.55 34.83 0.504 1 4.18 -20.75 32.07 0.647 1 / Pn controls Secondary Horizontal Design Data (Compression) Section No. Elevation Size ft T2 1 Pu 230 - 220 L3x3x3/16 L Lu ft ft 7.47 6.47 Kl/r 117.8 K=0.90 A Pu Pn in2 K 1.09 -0.39 K 16.85 Ratio Pu Pn 0.023 1 / Pn controls Top Girt Design Data (Compression) Section No. Elevation Size ft L Lu ft ft T1 240 - 230 L 2.5 x 2.5 x 3/16 6.00 5.00 T7 150 - 140 L 3 x 3 x 5/16 15.00 14.00 T9 130 - 120 KL/R > 200 (C) - 83 L3 1/2x3 1/2x5/16 17.00 16.00 Pu Pn in2 K 120.7 K=1.00 221.6 K=0.78 0.90 -0.04 K 13.57 Ratio Pu Pn 0.003 1 1.78 -1.82 8.19 0.222 1 217.3 K=0.78 2.09 -2.23 10.00 0.223 1 Kl/r A KL/R > 200 (C) - 104 1 Pu / Pn controls Tension Checks Page Job tnxTower 23 of 26 240-ft S/S Tower - MFP #24112-007 Project Michael F. Plahovinsak, P.E. Date 2012-05, Christopher 18301 State Route 161 W Plain City, OH 43064 Phone: 614-398-6250 FAX: mike@mfpeng.com 12:26:46 10/09/12 Client Designed by St. Charles Tower Mike Leg Design Data (Tension) Section No. Elevation Size 1 Kl/r A Pn K ft ft T1 240 - 230 Pirod 105217 (12x1.5) 10.02 10.02 37.8 5.30 0.33 K 238.57 T2 230 - 220 Pirod 105217 (12x1.5) 10.02 4.67 37.8 5.30 3.92 238.57 0.016 1 T3 220 - 200 Pirod 105217 (12x1.5) 20.03 10.02 37.8 5.30 26.93 238.57 0.113 1 T4 200 - 180 Pirod 105218 (12x1.75) 20.03 10.02 32.4 7.22 60.67 324.71 0.187 1 T5 180 - 160 Pirod 105218 (12x1.75) 20.03 10.02 32.4 7.22 93.95 324.71 0.289 1 T6 160 - 150 Pirod 105219 (12x2) 10.02 10.02 28.4 9.42 110.29 424.12 0.260 1 T7 150 - 140 Pirod 105219 (12x2) 10.02 10.02 28.4 9.42 126.94 424.12 0.299 1 T8 140 - 130 Pirod 105219 (12x2) 10.02 10.02 28.4 9.42 143.54 424.12 0.338 1 T9 130 - 120 Pirod 105219 (12x2) 10.02 10.02 28.4 9.42 160.18 424.12 0.378 1 T10 120 - 100 Pirod 105219 (12x2) 20.03 10.02 28.4 9.42 194.32 424.12 0.458 1 T11 100 - 80 Pirod 105220 (12x2.25) 20.03 10.02 25.2 11.93 228.05 536.77 0.425 1 T12 80 - 60 Pirod 105220 (12x2.25) 20.03 10.02 25.2 11.93 262.11 536.77 0.488 1 T13 60 - 40 Pirod 112743 20.03 20.03 32.6 14.73 284.53 662.68 0.429 1 T14 40 - 20 Pirod 112743 20.03 20.03 32.6 14.73 319.75 662.68 0.483 1 T15 20 - 0 Pirod 112738 (18x2.5) 20.03 20.03 32.6 14.73 347.37 662.68 0.524 1 Pu Lu Pu Ratio Pu Pn 0.001 1 ft L in 2 / Pn controls Truss-Leg Diagonal Data 120.0 Pn K 238.57 A in2 0.20 Vu K 0.27 Vn K 3.34 Stress Ratio 0.081 1.47 120.0 238.57 0.20 1.50 3.34 0.448 0.5 1.47 120.0 238.57 0.20 0.27 3.34 0.081 200 - 180 0.5 1.46 119.0 324.71 0.20 0.20 3.38 0.059 180 - 160 0.5 1.46 119.0 324.71 0.20 0.41 3.38 0.120 Section No. T1 Elevation ft 240 - 230 Diagonal Size 0.5 Ld ft 1.47 T2 230 - 220 0.5 T3 220 - 200 T4 T5 Kl/r Page Job tnxTower 24 of 26 240-ft S/S Tower - MFP #24112-007 Michael F. Plahovinsak, P.E. 18301 State Route 161 W Plain City, OH 43064 Phone: 614-398-6250 FAX: mike@mfpeng.com Project Date 2012-05, Christopher 12:26:46 10/09/12 Client Designed by St. Charles Tower Mike Section No. Elevation ft Diagonal Size Ld ft Kl/r Pn K A in2 Vu K Vn K Stress Ratio T6 160 - 150 0.625 1.45 94.4 424.12 0.31 0.64 6.96 0.092 T7 150 - 140 0.625 1.45 94.4 424.12 0.31 0.74 6.96 0.106 T8 140 - 130 0.625 1.45 94.4 424.12 0.31 0.70 6.96 0.101 T9 130 - 120 0.625 1.45 94.4 424.12 0.31 0.56 6.96 0.080 T10 120 - 100 0.625 1.45 94.4 424.12 0.31 0.28 6.96 0.041 T11 100 - 80 0.625 1.43 93.6 536.77 0.31 0.50 7.01 0.071 T12 80 - 60 0.625 1.43 93.6 536.77 0.31 1.12 7.01 0.160 T13 60 - 40 0.75 1.73 93.9 662.68 0.44 0.50 14.36 0.035 T14 40 - 20 0.75 1.73 93.9 662.68 0.44 0.83 14.36 0.058 T15 20 - 0 0.75 1.73 93.9 662.68 0.44 1.12 14.36 0.078 Diagonal Design Data (Tension) Section No. Elevation Size Lu Kl/r A Pu Pn K ft ft T1 240 - 230 L 2.5 x 2.5 x 3/16 11.93 5.32 84.9 0.52 0.54 K 22.55 Ratio Pu Pn 0.024 1 T2 230 - 220 L 2.5 x 2.5 x 3/16 12.50 5.65 89.9 0.52 2.66 22.55 0.118 1 T3 220 - 200 L3x3x3/16 13.80 6.35 83.5 0.66 6.99 28.68 0.244 1 T4 200 - 180 L3x3x3/16 15.24 7.10 93.2 0.66 7.79 28.68 0.272 1 T5 180 - 160 L3x3x3/16 16.80 7.86 103.4 0.62 8.44 27.15 0.311 1 T6 160 - 150 L 3 x 3 x 5/16 17.62 8.28 110.8 1.01 9.41 44.05 0.214 1 T7 150 - 140 L 3 x 3 x 5/16 18.45 8.70 116.3 1.01 9.38 44.05 0.213 1 T8 140 - 130 L3 1/2x3 1/2x5/16 19.30 9.13 104.0 1.25 10.44 54.17 0.193 1 T9 130 - 120 L3 1/2x3 1/2x5/16 20.16 9.56 108.8 1.25 10.56 54.17 0.195 1 T10 120 - 100 L3 1/2x3 1/2x5/16 21.92 10.45 118.6 1.25 11.89 54.17 0.219 1 T11 100 - 80 L 4 x 4 x 1/4 23.71 11.35 111.0 1.20 12.64 52.08 0.243 1 T12 80 - 60 L4x4x3/8 24.62 11.81 117.5 1.76 13.79 76.49 0.180 1 ft L in 2 18301 State Route 161 W Plain City, OH 43064 Phone: 614-398-6250 FAX: mike@mfpeng.com Elevation Project Date 2012-05, Christopher 12:26:46 10/09/12 Client Designed by St. Charles Tower Size ft 1 25 of 26 240-ft S/S Tower - MFP #24112-007 Michael F. Plahovinsak, P.E. Section No. Page Job tnxTower L Lu ft ft Kl/r Mike A Pu Pn in2 K K Ratio Pu Pn T13 60 - 40 2L 3.5 x 3.5 x 5/16 (1) 32.02 15.31 173.9 2.49 17.01 108.33 0.157 1 T14 40 - 20 2L 3.5 x 3.5 x 5/16 (1) 33.61 16.11 182.8 2.49 17.92 108.33 0.165 1 T15 20 - 0 2L 3.5 x 3.5 x 5/16 (1) 35.23 16.93 191.9 2.49 18.29 108.33 0.169 1 Pu / Pn controls Secondary Horizontal Design Data (Tension) Section No. Elevation Size ft T2 1 Pu 230 - 220 L3x3x3/16 L Lu ft ft 7.47 6.47 Kl/r Pu Pn in2 K 1.09 0.45 K 35.32 A 82.6 Ratio Pu Pn 0.013 1 / Pn controls Top Girt Design Data (Tension) Section No. Elevation Size 1 ft ft Kl/r Pn in2 K T1 240 - 230 L 2.5 x 2.5 x 3/16 6.00 5.00 77.0 0.90 0.03 K 29.22 T7 150 - 140 L 3 x 3 x 5/16 15.00 14.00 182.4 1.78 2.06 57.67 0.036 1 T9 130 - 120 L3 1/2x3 1/2x5/16 17.00 16.00 177.8 2.09 2.54 67.72 0.038 1 Pu Lu Pu Ratio Pu Pn 0.001 1 ft L A / Pn controls Section Capacity Table Elevation ft Component Type Size No. T1 Critical Element P K øPallow K % Capacity Pass Fail 240 - 230 T2 230 - 220 Leg Diagonal Top Girt Leg Diagonal Secondary Horizontal Pirod 105217 (12x1.5) L 2.5 x 2.5 x 3/16 L 2.5 x 2.5 x 3/16 Pirod 105217 (12x1.5) L 2.5 x 2.5 x 3/16 L3x3x3/16 1 8 4 13 17 23 -2.22 -0.62 -0.04 -7.04 -2.84 -0.39 214.86 12.18 13.57 214.86 10.87 16.85 8.1 5.1 0.7 44.8 26.2 2.3 Pass Pass Pass Pass Pass Pass Section Page Job tnxTower Michael F. Plahovinsak, P.E. 18301 State Route 161 W Plain City, OH 43064 Phone: 614-398-6250 FAX: mike@mfpeng.com Project Date 2012-05, Christopher 12:26:46 10/09/12 Client Designed by St. Charles Tower Mike Elevation ft Component Type Size No. T3 Critical Element P K øPallow K 220 - 200 T4 200 - 180 T5 180 - 160 T6 160 - 150 T7 150 - 140 T8 140 - 130 T9 130 - 120 T10 120 - 100 T11 100 - 80 T12 80 - 60 T13 60 - 40 T14 40 - 20 T15 20 - 0 Leg Diagonal Leg Diagonal Leg Diagonal Leg Diagonal Leg Diagonal Top Girt Leg Diagonal Leg Diagonal Top Girt Leg Diagonal Leg Diagonal Leg Diagonal Leg Diagonal Leg Diagonal Leg Diagonal Pirod 105217 (12x1.5) L3x3x3/16 Pirod 105218 (12x1.75) L3x3x3/16 Pirod 105218 (12x1.75) L3x3x3/16 Pirod 105219 (12x2) L 3 x 3 x 5/16 Pirod 105219 (12x2) L 3 x 3 x 5/16 L 3 x 3 x 5/16 Pirod 105219 (12x2) L3 1/2x3 1/2x5/16 Pirod 105219 (12x2) L3 1/2x3 1/2x5/16 L3 1/2x3 1/2x5/16 Pirod 105219 (12x2) L3 1/2x3 1/2x5/16 Pirod 105220 (12x2.25) L 4 x 4 x 1/4 Pirod 105220 (12x2.25) L4x4x3/8 Pirod 112743 2L 3.5 x 3.5 x 5/16 (1) Pirod 112743 2L 3.5 x 3.5 x 5/16 (1) Pirod 112738 (18x2.5) 2L 3.5 x 3.5 x 5/16 (1) 25 29 40 44 55 59 70 74 79 86 83 91 95 100 107 104 112 116 127 131 142 152 157 161 166 170 175 179 -34.68 -7.08 -71.59 -7.88 -108.37 -8.53 -126.59 -9.70 -145.79 -9.61 -1.82 -164.79 -10.68 -184.12 -10.94 -2.23 -223.77 -12.12 -263.41 -12.81 -304.47 -14.32 -331.26 -18.69 -376.12 -17.55 -410.04 -20.75 214.86 14.87 300.68 12.04 300.68 9.83 399.87 14.15 399.87 12.81 8.19 399.87 18.74 399.87 17.07 10.00 399.87 14.30 512.38 14.93 512.38 19.97 613.14 37.88 613.14 34.83 613.14 32.07 Section 26 of 26 240-ft S/S Tower - MFP #24112-007 % Capacity Pass Fail 16.1 47.6 23.8 65.5 36.0 86.7 31.7 68.6 36.5 75.0 22.2 41.2 57.0 46.0 64.1 22.3 56.0 84.7 51.4 85.8 59.4 71.7 54.0 49.3 61.3 50.4 66.9 64.7 Summary Leg (T15) 66.9 Diagonal 86.7 (T5) Secondary 2.3 Horizontal (T2) Top Girt 22.3 (T9) Bolt Checks 52.7 RATING = 86.7 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass
Similar documents
PSA-Dewberry Inc. 009113.1- 1 Addendum No. 1 January 4, 2011
REVISE dimension of W16x26 beams south of grid line A, between lines 5 and 9, from 1’-10” to 1’-6”. The south edge of slab remains in the same location with the extension distance changing to 10” a...
More information