WIRE AND CABLE SOLUTIONS
Transcription
WIRE AND CABLE SOLUTIONS
WIRE AND CABLE SOLUTIONS MARINE PRODUCT CATALOGUE WIRE AND CABLE SOLUTIONS Contents About ShawFlex Capabilities Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Product Selection Guide IEC (Metric) Instrumentation, Pairs & Triads (250V) . . . . . . . . . . . . . . . . . . Power & Control, Single Conductor (600/1000V) . . . . . . . . . Power & Control, Multi-Conductor (600/1000V) . . . . . . . . . . Power & Control, Single Conductor (Armoured - 600/1000V) . Power & Control, Multi-Conductor (Armoured - 600/1000V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 . 7 . 8 10 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 14 15 17 18 IEC (AWG) Instrumentation, Pairs & Triads (250V) . . . . . . . . . . . . . . . . . . Power & Control, Single Conductor (600/1000V) . . . . . . . . . Power & Control, Multi-Conductor (600/1000V) . . . . . . . . . . Power & Control, Single Conductor (Armoured - 600/1000V) . Power & Control, Multi-Conductor (Armoured - 600/1000V) . . IEEE 1580 (AWG) Instrumentation, Pairs & Triads (300V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Control, Single Conductor (600/1000V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Control, Multi-Conductor (600/1000V)) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 1 800 668 4842 shawflex.com Please note: Although the content used for this brochure has been produced and processed from sources believed to be reliable, no warranty, expressed or implied, is made regarding accuracy, adequacy, completeness, legality, reliability or usefulness of any information RODUCT CATALOG | 3 INNOVATIVE WIRE AND CABLE SOLUTIONS From common to custom ShawFlex is committed to leading the industry with innovative solutions that are proven, dependable and tested to the highest standards and precisely manufactured to your specifications. Many customers rely on our unique in-house design capability and expertise to tackle projects of all scopes and sizes. We provide comprehensive services, advanced in-house materials and product research as well as product development and pre-qualification testing. We offer customers much more than a catalogue of products. We provide the technical leadership and service responsiveness needed to meet all of your project deadlines as well as your performance requirements to produce a dependable and superior product. V.2 | 5 The design process ShawFlex is uniquely positioned as both a run to order and an engineered to order wire and cable company. Run to order products are available from our extensive catalogue of standard constructions/items. For engineered to order cables, our highly skilled technical team will work with you to interpret performance criteria, determine innovative solutions and optimize cable capabilities while ensuring the cable meets all applicable safety and specification requirements. ShawFlex is ready to help you meet the high performance needs of today. KEY MARKETS Oil & Gas Industrial Utilities •Oil and gas investment •Construction developments •Power generation •Refinery expansion •Maintenance, repair and operations •Nuclear refurbishment and new builds •Forestry •Wastewater treatment •Mining •Transmission upgrades MARINE METRIC V.2 | 6 IEC INSTRUMENTATION | PAIRS & TRIADS (250V) PAGE 1 OF 1 ShawFlex IEC Instrumentation cables are suitable for use in offshore oil and gas, shipboard and marine applications. Our cables are made to IEC specifications and can be modified to fit your specific requirements. Voltage Certifications/Compliances 250V • IEC 60092-350 • IEC 60754-1 • IEC 61034-1&2 • EC 60228 Class 5 • IEC 60092-353, Control & Power • IEC 60092-376, Instrumentation • IEC 60332-3-22, Category A Flame Propagate Testing • Lloyd’s Register • American Bureau of Shipping • Transport Canada • RoHS Compliant • UV sunlight resistant “SUN RES” (all colours) • - 40°C cold bend rated • - 35°C cold impact rated Product Construction • Insulation: - XLPE (RW90 rated) rated: 90°C wet/dry, 60092-351 • Shielding: - Aluminum/mylar foil shield with tinned copper drain wire (standard), available for both individual and overall shields - Aluminum/mylar foil shield with drain wire (optional) • Jacket: - LSZH Thermoplastic, black (standard) rated: 75°C , SHF1 IEC 60092-359 • Available in: - Custom insulation/jacket colours Colour Coding 5 1 2 3 4 6 7 1. High Strand Bare Copper Conductors (Tinned Available) 2. Halogen Free XLPE (RW90 Rated) Insulated Conductors 3. Fiberglass Tape 4. Polyester Separator Tape 5. Overall Aluminum/Mylar Shield with Tinned Copper Drain Wire 6. Protective LSZH Jacket • Pairs - White, blue, # coded • Triads - White, blue, red, # coded ShawFlex can manufacture up to 50 components in 0.75mm2, 1.5mm2, and 2.5mm2 Part Number Number of Pairs/Triads Cross Section (mm2) Nominal OD Overall Cable (in/mm) Cable Weight (lbs/1000ft)/(kg/km) Ampacity (45°C ambient) SF021E1B01F0801 1PR 0.75 6.8 / 0.27 70 / 47 15 SF022E1B02F0801 2PR 0.75 11.1 / 0.44 153 / 102 11 SF022E1B04F0801 4PR 0.75 13 / 0.51 227 / 153 8 SF022E1B08F0801 8PR 0.75 16.8 / 0.66 380 / 255 8 SF022E1B12F0801 12PR 0.75 20.5 / 0.81 541 / 363 8 SF022E1B16F0801 16PR 0.75 23 / 0.91 685 / 460 7 SF022E1B24F0801 24PR 0.75 28.3 / 1.12 1001 / 673 6 SF021E3A01F0801 1PR 1.5 8.5 / 0.34 104 / 70 20 SF022E3A02F0801 2PR 1.5 13.9 / 0.55 231 / 156 16 SF022E3A04F0801 4PR 1.5 16.3 / 0.64 353 / 237 11 SF022E3A08F0801 8PR 1.5 21.3 / 0.84 592 / 398 11 SF022E3A12F0801 12PR 1.5 26.3 / 1.04 870 / 585 11 SF022E3A16F0801 16PR 1.5 29.5 / 1.16 1102 / 741 10 SF022E3A24F0801 24PR 1.5 36.8 / 1.45 1646 / 1106 8 SF031E1B01F0801 1TRD 0.75 7.2 / 0.28 82 / 55 11 SF032E1B02F0801 2TRD 0.75 12.5 / 0.49 196 / 131 9 SF032E1B04F0801 4TRD 0.75 14.4 / 0.57 287 / 193 8 SF032E1B08F0801 8TRD 0.75 19 / 0.75 498 / 335 8 SF031E3A01F0801 1TRD 1.5 8.9 / 0.35 125 / 84 16 SF032E3A02F0801 2TRD 1.5 15.7 / 0.62 301 / 202 13 SF032E3A04F0801 4TRD 1.5 18.2 / 0.72 449 / 302 11 SF032E3A08F0801 8TRD 1.5 24.1 / 0.95 784 / 527 11 *Ampacity value based on Canadian Electrical Code, Version 2012, Table-2. Values are corrected according to Table-5C for number of Conductors. 1 800 668 4842 shawflex.com Please note: Although the content used for this brochure has been produced and processed from sources believed to be reliable, no warranty, expressed or implied, is made regarding accuracy, adequacy, completeness, legality, reliability or usefulness of any information MARINE METRIC V.2 | 7 IEC POWER & CONTROL | SINGLE CONDUCTOR (600/1000V) PAGE 1 OF 1 ShawFlex IEC Power and Control cables are suitable for use in offshore oil and gas, shipboard and marine applications. Our cables are made to IEC specifications and can be modified to fit your specific requirements. Voltage Certifications/Compliances 600/1000V • IEC 60092-350 • IEC 60754-1 • IEC 61034-1&2 • IEC60228 Class 5 • IEC 60092-353, Control & Power • IEC 60092-376, Instrumentation • IEC 60332-3-22, Category A Flame Propagate Testing • Lloyd’s Register • American Bureau of Shipping • Transport Canada • RoHS Compliant • UV sunlight resistant “SUN RES” (all colours) • - 40°C cold bend rated • - 35°C cold impact rated Product Construction • Insulation: - Halogen Free XLPE (RW90 rated) rated: 90°C wet/dry, IEC 60092-351 • Jacket: - LSZH Thermoplastic, black (standard) rated: 75°C , SHF1 IEC 60092-359 • Available in: - Custom insulation/jacket colours 1 2 3 1. High Strand Bare Copper Conductors (Tinned Available) 2. Halogen Free XLPE (RW90 Rated) Insulated Conductors 3. Protective LSZH Jacket Colour Coding • Black conductor (standard) Part Number Number of Conductors Cross Section (mm2) Nominal OD Overall Cable (in/mm) Cable Weight (lbs/1000ft)/(kg/km) Ampacity (45°C ambient) SE010E3A01F0801 1 1.5 5.5 / 0.22 50 / 33 23 SE010E5A01F0801 1 2.5 5.9 / 0.23 62 / 42 26 SE010E0401F0801 1 4 6.6 / 0.26 83 / 56 35 SE010E0601F0801 1 6 7.2 / 0.28 105 / 70 47 SE010E1001F0801 1 10 8.2 / 0.32 152 / 102 64 SE010E1601F0801 1 16 9.7 / 0.38 226 / 152 85 SE010E2501F0801 1 25 11.5 / 0.45 332 / 223 114 SE010E3501F0801 1 35 12.7 / 0.5 427 / 287 152 SE010E5001F0801 1 50 14.2 / 0.56 580 / 390 176 SE010E7001F0801 1 70 16.8 / 0.66 793 / 533 204 SE010E9501F0801 1 95 18.7 / 0.74 1009 / 678 272 SE010E1C01F0801 1 120 20.7 / 0.81 1280 / 860 315 SE010E1D01F0801 1 150 22.4 / 0.88 1586 / 1066 357 SE010E1E01F0801 1 185 24.7 / 0.97 1924 / 1293 432 SE010E2C01F0801 1 240 27.1 / 1.07 2523 / 1695 541 SE010E3F01F0801 1 300 31 / 1.22 3100 / 2083 580 *Ampacity value based on Canadian Electrical Code, Version 2012, Table-2. Values are corrected according to Table-5C for number of Conductors. 1 800 668 4842 shawflex.com Please note: Although the content used for this brochure has been produced and processed from sources believed to be reliable, no warranty, expressed or implied, is made regarding accuracy, adequacy, completeness, legality, reliability or usefulness of any information MARINE METRIC V.2 | 8 IEC POWER & CONTROL | MULTI-CONDUCTOR (600/1000V) PAGE 1 OF 2 ShawFlex IEC Power and Control cables are suitable for use in offshore oil and gas, shipboard and marine applications. Our cables are made to IEC specifications and can be modified to fit your specific requirements. Voltage Certifications/Compliances 600/1000V • IEC 60092-350 • IEC 60754-1 • IEC 61034-1&2 • EC 60228 Class 5 • IEC 60092-353, Control & Power • IEC 60092-376, Instrumentation • IEC 60332-3-22, Category A Flame Propagate Testing • Lloyd’s Register • American Bureau of Shipping • Transport Canada • RoHS Compliant • UV sunlight resistant “SUN RES” (all colours) • - 40°C cold bend rated • - 35°C cold impact rated Product Construction • Insulation: - Halogen Free XLPE (RW90 rated rated: 90°C wet/dry, 60092-351 • Shield: - Aluminum/mylar foil shield with drain wire (optional) • Jacket: - LSZH Thermoplastic, black (standard) rated: 75°C , SHF1 IEC 60092-359 • Available in: - Custom insulation/jacket colours Colour Coding • 2C – Brown, blue • 3C – Brown, black, grey • 4C – Brown, black, grey, blue • 5C & higher– Black # Coded 3 1 2 5 4 6 1. High Stranded Bare Copper Conductors (Tinned Available) 2. Halogen Free XLPE (RW90 Rated) Insulated Conductors 3. Polypropylene Fillers 4. Fiberglass Tape 5. Polyester Separator Tape 6. Protective LSZH Jacket ShawFlex can manufacture up to 50 conductors in 0.75mm2, 1.5mm2, and 2.5mm2 Part Number Number of Conductors Cross Section (mm2) Nominal OD Overall Cable (in/mm) Cable Weight (lbs/1000ft)/ (kg/km) Ampacity (45°C ambient) SE010E3A02F0801 2 1.5 9.3 / 0.37 111 / 75 20 SE010E5A02F0801 2 2.5 10.1 / 0.4 138 / 93 22 SE010E0402F0801 2 4 11.8 / 0.47 197 / 132 30 SE010E0602F0801 2 6 13 / 0.51 247 / 166 39 SE010E1002F0801 2 10 14.5 / 0.57 339 / 228 54 SE010E1602F0801 2 16 17.7 / 0.7 518 / 348 73 SE010E2502F0801 2 25 21 / 0.83 752 / 506 97 SE010E3502F0801 2 35 23.8 / 0.94 983 / 661 128 SE010E5002F0801 2 50 26.9 / 1.06 1345 / 904 150 SE010E3A03F0801 3 1.5 9.7 / 0.38 132 / 89 16 SE010E5A03F0801 3 2.5 10.7 / 0.42 167 / 112 19 SE010E0403F0801 3 4 12.5 / 0.49 242 / 163 24 SE010E0603F0801 3 6 13.7 / 0.54 311 / 209 33 SE010E1003F0801 3 10 15.6 / 0.61 452 / 304 44 SE010E1603F0801 3 16 19 / 0.75 690 / 464 59 SE010E2503F0801 3 25 22.5 / 0.89 1015 / 683 80 SE010E3503F0801 3 35 25.5 / 1 1344 / 903 106 SE010E5003F0801 3 50 28.9 / 1.14 1845 / 1240 123 SE010E3A04F0801 4 1.5 10.6 / 0.42 158 / 106 16 SE010E5A04F0801 4 2.5 11.8 / 0.47 213 / 143 19 SE010E0404F0801 4 4 13.6 / 0.53 295 / 198 24 SE010E0604F0801 4 6 15.2 / 0.6 399 / 268 33 *Ampacity value based on Canadian Electrical Code, Version 2012, Table-2. Values are corrected according to Table-5C for number of Conductors. 1 800 668 4842 shawflex.com Please note: Although the content used for this brochure has been produced and processed from sources believed to be reliable, no warranty, expressed or implied, is made regarding accuracy, adequacy, completeness, legality, reliability or usefulness of any information MARINE METRIC IEC POWER & CONTROL | MULTI-CONDUCTOR (600/1000V) V.2 | 9 PAGE 2 OF 2 Part Number Number of Conductors Cross Section (mm2) Nominal OD Overall Cable (in/mm) Cable Weight (lbs/1000ft)/ (kg/km) Ampacity (45°C ambient) SE010E1004F0801 4 10 17 / 0.67 567 / 381 44 SE010E1604F0801 4 16 20.8 / 0.82 870 / 584 59 SE010E2504F0801 4 25 24.7 / 0.97 1292 / 868 80 SE010E3504F0801 4 35 28.1 / 1.1 1707 / 1147 106 SE010E5004F0801 4 50 31.8 / 1.25 2366 / 1590 123 SE010E3A05F0801 5 1.5 11.7 / 0.46 189 / 127 13 SE010E5A05F0801 5 2.5 12.9 / 0.51 255 / 171 15 SE010E3A07F0801 7 1.5 12.7 / 0.5 232 / 156 11 SE010E5A07F0801 7 2.5 14 / 0.55 310 / 208 13 SE010E3A10F0801 10 1.5 16.1 / 0.63 335 / 225 11 SE010E5A10F0801 10 2.5 17.8 / 0.7 447 / 300 13 SE010E3A12F0801 12 1.5 16.6 / 0.65 376 / 252 11 SE010E5A12F0801 12 2.5 18.6 / 0.73 520 / 349 13 *Ampacity value based on Canadian Electrical Code, Version 2012, Table-2. Values are corrected according to Table-5C for number of Conductors. 1 800 668 4842 shawflex.com Please note: Although the content used for this brochure has been produced and processed from sources believed to be reliable, no warranty, expressed or implied, is made regarding accuracy, adequacy, completeness, legality, reliability or usefulness of any information MARINE METRIC V.2 | 10 IEC ARMOURED POWER & CONTROL | SINGLE CONDUCTOR (600/1000V) PAGE 1 OF 1 ShawFlex IEC Armoured Power and Control cables are suitable for use in offshore oil and gas, shipboard and marine applications. Our cables are made to IEC specifications and can be modified to fit your specific requirements. Voltage Certifications/Compliances 600/1000V • IEC 60092-350 • IEC 60754-1 • IEC 61034-1&2 IEC 60228 Class 5 • IEC 60092-353, Control & Power • IEC 60092-376, Instrumentation • IEC 60332-3-22, Category A Flame Propagate Testing • Lloyd’s Register • American Bureau of Shipping • Transport Canada • RoHS Compliant • UV sunlight resistant “SUNRES” (all colours) • - 40°C cold bend rated • - 35°C cold impact rated Product Construction • Insulation: - XLPE RW90 rated rated: 90°C wet/90°C dry, 60092-351 • Armour: - Tinned copper braid (optional) - Bronze braid (optional) Jacket: - LSZH Thermoplastic, black (standard) rated: 75°C , SHF1 IEC 60092-359 • Available in: - Custom insulation/jacket colours 1 2 3 5 6 1. High Strand Bare Copper Conductors (Tinned Available) 2. Halogen Free XLPE (RW90 Rated) Insulated Conductors 3. Polypropylene Fillers 4. Polyester Separator Tape 5. Tinned Copper Braided Armour 6. Protective LSZH Jacket Colour Coding • Black conductor (standard) Part Number Number of Conductors Cross Section (mm2) Nominal OD Overall Cable (in/mm) Cable Weight (lbs/1000ft)/(kg/km) Ampacity (45°C ambient) SEC10E3A01F0809 1 1.5 8.3 / 0.33 133 / 89 23 SEC10E5A01F0809 1 2.5 9 / 0.35 158 / 106 26 SEC10E0401F0809 1 4 9.7 / 0.38 188 / 127 35 SEC10E0601F0809 1 6 10.3 / 0.41 218 / 147 47 SEC10E1001F08N9 1 10 9.2 / 0.36 202 / 136 64 SEC10E1601F08N9 1 16 10.7 / 0.42 286 / 192 85 SEC10E2501F08N9 1 25 12.5 / 0.49 403 / 271 114 *Ampacity value based on Canadian Electrical Code, Version 2012, Table-2. Values are corrected according to Table-5C for number of Conductors. 1 800 668 4842 shawflex.com Please note: Although the content used for this brochure has been produced and processed from sources believed to be reliable, no warranty, expressed or implied, is made regarding accuracy, adequacy, completeness, legality, reliability or usefulness of any information MARINE METRIC V.2 | 11 IEC ARMOURED POWER & CONTROL | MULTI-CONDUCTOR (600/1000V) PAGE 1 OF 1 ShawFlex IEC Armoured Power and Control cables are suitable for use in offshore oil and gas, shipboard and marine applications. Our cables are made to IEC specifications and can be modified to fit your specific requirements. Voltage Certifications/Compliances 600/1000V • IEC 60092-350 • IEC 60754-1 • IEC 61034-1&2 • IEC 60228 Class 5 IEC 60092-353, Control & Power • IEC 60092-376, Instrumentation • IEC 60332-3-22, Category A Flame Propagate Testing • Lloyd’s Register • American Bureau of Shipping • Transport Canada • RoHS Compliant • UV sunlight resistant “SUNRES” (all colours) • - 40°C cold bend rated • - 35°C cold impact rated Product Construction • Insulation: - XLPE (RW90 rated) rated: 90°C wet/dry, 60092-351 • Armour: - Tinned copper braid (optional) - Bronze braid (optional) Jacket: - LSZH Thermoplastic, black (standard) rated: 75°C , SHF1 IEC 60092-359 • Available in: - Custom insulation/jacket colours Colour Coding • 2C – Brown, blue • 3C – Brown, black, grey • 4C – Brown, black, grey, blue • 5C & higher– Black # Coded 4 1 2 3 5 6 7 1. High Strand Bare Copper Conductors (Tinned Available) 2. Halogen Free XLPE (RW90 Rated) Insulated Conductors 3. Polypropylene Fillers 4. Fiberglass Tape 5. Polyester Separator Tape 6. Tinned Copper Braided Armour 7. Protective LSZH Jacket ShawFlex can manufacture up to 50 conductors in 0.75mm2, 1.5mm2, and 2.5mm2 Nominal OD Overall Cable (in/mm) Cable Weight (lbs/1000ft)/(kg/km) Ampacity (45°C ambient) 10.1 / 0.4 164 / 110 20 11.1 / 0.44 201 / 135 22 Part Number Number of Conductors Cross Section (mm2) SEC10E3A02F08N9 2 1.5 SEC10E5A02F08N9 2 2.5 SEC10E0402F08N9 2 4 12.8 / 0.5 271 / 182 30 SEC10E0602F08N9 2 6 14.4 / 0.57 365 / 246 39 54 SEC10E1002F08N9 2 10 16.1 / 0.64 484 / 326 SEC10E1602F08N9 2 16 19.3 / 0.76 696 / 468 73 SEC10E2502F08N9 2 25 22.6 / 0.89 964 / 648 97 SEC10E3502F08N9 2 35 25.2 / 0.99 1211 / 813 128 SEC10E3A03F08N9 3 1.5 10.7 / 0.42 193 / 129 16 SEC10E5A03F08N9 3 2.5 11.9 / 0.47 243 / 164 19 SEC10E0403F08N9 3 4 13.5 / 0.53 321 / 216 24 SEC10E0603F08N9 3 6 15.4 / 0.61 448 / 301 33 SEC10E1003F08N9 3 10 17 / 0.67 594 / 399 44 SEC10E1603F08N9 3 16 20.4 / 0.8 865 / 581 59 SEC10E2503F08N9 3 25 23.9 / 0.94 1223 / 822 80 SEC10E3503F08N9 3 35 26.9 / 1.06 1586 / 1066 106 SEC10E3A04F08N9 4 1.5 11.8 / 0.47 234 / 157 16 SEC10E5A04F08N9 4 2.5 12.8 / 0.51 288 / 193 19 SEC10E0404F08N9 4 4 15.2 / 0.61 431 / 290 24 SEC10E0604F08N9 4 6 16.6 / 0.66 538 / 362 33 SEC10E1004F08N9 4 10 18.7 / 0.74 739 / 496 44 SEC10E1604F08N9 4 16 22.5 / 0.89 1080 / 726 59 *Ampacity value based on Canadian Electrical Code, Version 2012, Table-2. Values are corrected according to Table-5C for number of Conductors. 1 800 668 4842 shawflex.com Please note: Although the content used for this brochure has been produced and processed from sources believed to be reliable, no warranty, expressed or implied, is made regarding accuracy, adequacy, completeness, legality, reliability or usefulness of any information MARINE METRIC V.2 | 12 IEC ARMOURED POWER & CONTROL | MULTI-CONDUCTOR (600/1000V) PAGE 1 OF 1 Part Number Number of Conductors Cross Section (mm 2) Nominal OD Overall Cable (in/mm) Cable Weight (lbs/1000ft)/(kg/km) Ampacity (45°C ambient) SEC10E2504F08N9 4 25 26.4 / 1.04 1543 / 1037 80 SEC10E3504F08N9 4 35 29.7 / 1.17 1998 / 1342 24 SEC10E3A05F08N9 5 1.5 12.7 / 0.5 262 / 176 25 SEC10E5A05F08N9 5 2.5 14.3 / 0.56 372 / 250 26 SEC10E3A07F08N9 7 1.5 13.7 / 0.54 313 / 210 27 SEC10E5A07F08N9 7 2.5 15.6 / 0.62 450 / 303 28 SEC10E3A10F08N9 10 1.5 17.5 / 0.69 483 / 325 29 SEC10E5A10F08N9 10 2.5 19.4 / 0.77 627 / 421 30 SEC10E3A12F08N9 12 1.5 18 / 0.71 528 / 355 31 SEC10E5A12F08N9 12 2.5 20 / 0.79 691 / 464 32 *Ampacity value based on Canadian Electrical Code, Version 2012, Table-2. Values are corrected according to Table-5C for number of Conductors. 1 800 668 4842 shawflex.com Please note: Although the content used for this brochure has been produced and processed from sources believed to be reliable, no warranty, expressed or implied, is made regarding accuracy, adequacy, completeness, legality, reliability or usefulness of any information MARINE V.2 | 13 AWG IEC INSTRUMENTATION | PAIRS & TRIADS (250V) PAGE 1 OF 1 ShawFlex IEC Instrumentation cables are suitable for use in offshore oil and gas, shipboard and marine applications. Our cables are made to IEC specifications and can be modified to fit your specific requirements. Voltage Certifications/Compliances 250V • IEC 60092-350 • IEC 60754-1 • IEC 61034-1&2 • EC 60228 Class 5 • IEC 60092-353, Control & Power • IEC 60092-376, Instrumentation • IEC 60332-3-22, Category A Flame Propagate Testing • Lloyd’s Register • American Bureau of Shipping • Transport Canada • RoHS Compliant • UV sunlight resistant “SUN RES” (all colours) • - 40°C cold bend rated • - 35°C cold impact rated Product Construction • Insulation: - XLPE (RW90 rated) RW90 rated: 90°C wet/dry, 60092-351 • Shielding: - Aluminum/mylar foil shield with tinned copper drain wire (standard), available for both individual and overall shields - Aluminum/mylar foil shield with drain wire (optional) • Jacket: - LSZH Thermoplastic, black (standard) rated: 75°C , SHF1 IEC 60092-359 • Available in: - Custom insulation/jacket colours Colour Coding 5 1 2 3 4 6 7 1. High Strand Bare Copper Conductors (Tinned Available) 2. XLPE (RW90 Rated) Insulated Conductors 3. Fiberglass Tape 4. Polyester Separator Tape 5. Overall Aluminum/Mylar Shield with Tinned Copper Drain Wire 6. Protective LSZH Jacket • Pairs - White, blue, # coded • Triads - White, blue, red, # coded Part Number Number of Pairs/Triads Cross Section (AWG/MCM) Nominal OD Overall Cable (in/mm) Cable Weight (lbs/1000ft)/(kg/km) Ampacity (45°C ambient) SF021U180100800 1PR 18 6.93 / 0.27 72 / 48 15 SF022U180200800 2PR 18 11.25 / 0.44 157 / 106 11 SF022U180400800 4PR 18 13.2 / 0.52 234 / 157 7.7 SF022U180800800 8PR 18 17.13 / 0.67 392 / 263 7.7 SF022U181200800 12PR 18 20.9 / 0.82 558 / 375 7.7 SF022U181600800 16PR 18 23.43 / 0.92 706 / 475 6.6 SF022U182400800 24PR 18 28.89 / 1.14 1033 / 694 5.5 SF021U160100800 1PR 16 8.31 / 0.33 102 / 68 20 SF022U160200800 2PR 16 13.51 / 0.53 222 / 149 16 SF022U160400800 4PR 16 15.88 / 0.63 340 / 228 11.2 SF022U160800800 8PR 16 20.71 / 0.82 569 / 382 11.2 SF022U161200800 12PR 16 25.59 / 1.01 831 / 558 11.2 SF022U161600800 16PR 16 28.41 / 1.12 1034 / 695 9.6 SF022U162400800 24PR 16 35.43 / 1.4 1545 / 1039 8 SF031U180100800 1TRD 18 7.27 / 0.29 85 / 57 11 SF032U180200800 2TRD 18 12.7 / 0.5 202 / 136 8.8 SF032U180400800 4TRD 18 14.64 / 0.58 297 / 199 7.7 SF032U180800800 8TRD 18 19.36 / 0.76 514 / 346 7.7 SF031U160100800 1TRD 16 8.72 / 0.34 121 / 81 16 SF032U160200800 2TRD 16 15.26 / 0.6 291 / 195 12.8 SF032U160400800 4TRD 16 17.67 / 0.7 430 / 289 11.2 SF032U160800800 8TRD 16 23.42 / 0.92 759 / 510 11.2 *Ampacity value based on National Electrical Code, Version 2011, Table 3-10.15(B)(16). Values are corrected according to Table 310.15(B)(16) for number of Conductors. 1 800 668 4842 shawflex.com Please note: Although the content used for this brochure has been produced and processed from sources believed to be reliable, no warranty, expressed or implied, is made regarding accuracy, adequacy, completeness, legality, reliability or usefulness of any information MARINE V.2 | 14 AWG IEC POWER & CONTROL | SINGLE CONDUCTOR (600/1000V) PAGE 1 OF 1 ShawFlex IEC Power and Control cables are suitable for use in offshore oil and gas, shipboard and marine applications. Our cables are made to IEC specifications and can be modified to fit your specific requirements. Voltage Certifications/Compliances 600/1000V • IEC 60092-350 • IEC 60754-1 • IEC 61034-1&2 • EC 60228 Class 5 • IEC 60092-353, Control & Power • IEC 60092-376, Instrumentation • IEC 60332-3-22, Category A Flame Propagate Testing • Lloyd’s Register • American Bureau of Shipping • Transport Canada • RoHS Compliant • UV sunlight resistant “SUN RES” (all colours) • - 40°C cold bend rated • - 35°C cold impact rated Product Construction • Insulation: - XLPE (RW90 rated) rated: 90°C wet/dry, 60092-351 • Jacket: - LSZH Thermoplastic, black (standard) rated: 75°C , SHF1 IEC 60092-359 • Available in: - Custom insulation/jacket colours 1 2 3 1. High Strand Bare Copper Conductors (Tinned Available) 2. XLPE (RW90 Rated) Insulated Conductors 3. Protective LSZH Jacket Colour Coding • Black conductor (standard) Part Number Number of Conductors Cross Section (AWG/MCM) Nominal OD Overall Cable (in/mm) Cable Weight (lbs/1000ft)/(kg/km) Ampacity (45°C ambient) SE010U160100800 1 16 5.38 / 0.21 49 / 33 23 SE010U140100800 1 14 5.71 / 0.22 58 / 39 26 SE010U120100800 1 12 6.17 / 0.24 74 / 49 35 SE010U100100800 1 10 6.81 / 0.27 97 / 65 47 SE010U080100800 1 8 7.54 / 0.3 134 / 90 64 SE010U060100800 1 6 8.74 / 0.34 196 / 131 85 SE010U040100800 1 4 10.19 / 0.4 286 / 192 114 SE010U020100800 1 2 11.91 / 0.47 426 / 286 152 SE010U010140800 1 1 13.16 / 0.52 522 / 351 176 SE010U1/0140800 1 1/0 14.43 / 0.57 643 / 432 204 SE010U2/0140800 1 2/0 15.77 / 0.62 797 / 536 235 SE010U250160800 1 250 20.17 / 0.79 1420 / 954 357 SE010U350160800 1 350 23.7 / 0.93 1969 / 1323 432 SE010U500160800 1 500 27.41 / 1.08 2752 / 1849 541 SE010U600160800 1 600 30.28 / 1.19 3309 / 2223 580 SE010U750160800 1 750 33.07 / 1.3 4081 / 2742 667 *Ampacity value based on National Electrical Code, Version 2011, Table 3-10.15(B)(16). Values are corrected according to Table 310.15(B)(16) for number of Conductors. 1 800 668 4842 shawflex.com Please note: Although the content used for this brochure has been produced and processed from sources believed to be reliable, no warranty, expressed or implied, is made regarding accuracy, adequacy, completeness, legality, reliability or usefulness of any information MARINE V.2 | 15 AWG IEC POWER & CONTROL | MULTI-CONDUCTOR (600/1000V) PAGE 1 OF 2 ShawFlex IEC Power and Control cables are suitable for use in offshore oil and gas, shipboard and marine applications. Our cables are made to IEC specifications and can be modified to fit your specific requirements. Voltage Certifications/Compliances 600/1000V • IEC 60092-350 • IEC 60754-1 • IEC 61034-1&2 • IEC60228 Class 5 • IEC 60092-353, Control & Power • IEC 60092-376, Instrumentation • IEC 60332-3-22, Category A Flame Propagate Testing • Lloyd’s Register • American Bureau of Shipping • Transport Canada • RoHS Compliant • UV sunlight resistant “SUN RES” (all colours) • - 40°C cold bend rated • - 35°C cold impact rated Product Construction • Insulation: - XLPE (RW90 rated) rated: 90°C wet/dry, IEC 60092-351 • Jacket: - LSZH Thermoplastic, black (standard) rated: 75°C , SHF1 IEC 60092-359 • Available in: - Custom insulation/jacket colours 3 1 2 5 4 6 1. High Stranded Bare Copper Conductors (Tinned Available) 2. XLPE (RW90 Rated) Insulated Conductors 3. Polypropylene Fillers 4. Fiberglass Tape 5. Polyester Separator Tape 6. Protective LSZH Jacket Colour Coding • 2C – Brown, blue • 3C – Brown, black, grey • 4C – Brown, black, grey, blue • 5C & higher– Black # Coded Part Number Number of Conductors Cross Section (AWG/MCM) Nominal OD Overall Cable (in/mm) Cable Weight (lbs/1000ft)/ (kg/km) Ampacity (45°C ambient) SE010U160200800 2 16 9.07 / 0.36 109 / 73 20 SE010U140200800 2 14 9.73 / 0.38 130 / 87 22 SE010U120200800 2 12 10.64 / 0.42 165 / 111 30 SE010U100200800 2 10 12.17 / 0.48 227 / 153 39 SE010U080200800 2 8 13.64 / 0.54 313 / 210 54 SE010U060200800 2 6 15.77 / 0.62 440 / 295 73 SE010U040200800 2 4 18.92 / 0.75 657 / 442 97 SE010U020200800 2 2 22.12 / 0.87 970 / 652 128 SE010U010240800 2 1 24.61 / 0.97 1188 / 798 150 SE010U160300800 3 16 9.53 / 0.38 128 / 86 16 SE010U140300800 3 14 10.24 / 0.4 156 / 105 19 SE010U120300800 3 12 11.47 / 0.45 215 / 145 24 SE010U100300800 3 10 12.84 / 0.51 288 / 193 33 SE010U080300800 3 8 14.42 / 0.57 405 / 272 44 SE010U060300800 3 6 16.7 / 0.66 576 / 387 59 SE010U040300800 3 4 20.06 / 0.79 873 / 586 80 SE010U020300800 3 2 23.48 / 0.92 1311 / 881 106 SE010U010340800 3 1 26.41 / 1.04 1636 / 1099 123 SE010U160400800 4 16 10.32 / 0.41 148 / 99 16 SE010U140400800 4 14 11.11 / 0.44 190 / 128 19 SE010U120400800 4 12 12.47 / 0.49 260 / 175 24 SE010U100400800 4 10 14 / 0.55 359 / 241 33 *Ampacity value based on National Electrical Code, Version 2011, Table 3-10.15(B)(16). Values are corrected according to Table 310.15(B)(16) for number of Conductors. 1 800 668 4842 shawflex.com Please note: Although the content used for this brochure has been produced and processed from sources believed to be reliable, no warranty, expressed or implied, is made regarding accuracy, adequacy, completeness, legality, reliability or usefulness of any information MARINE V.2 | 16 AWG IEC POWER & CONTROL | MULTI-CONDUCTOR (600/1000V) PAGE 2 OF 2 Part Number Number of Conductors Cross Section (AWG/MCM) Nominal OD Overall Cable (in/mm) Cable Weight (lbs/1000ft)/ (kg/km) Ampacity (45°C ambient) SE010U080400800 4 8 16.03 / 0.63 521 / 350 44 752 / 506 59 SE010U060400800 4 6 18.55 / 0.73 SE010U040400800 4 4 22.29 / 0.88 1140 / 766 80 SE010U020400800 4 2 26.09 / 1.03 1706 / 1146 106 SE010U010440800 4 1 29.35 / 1.16 2128 / 1430 123 SE010U160500800 5 16 11.2 / 0.44 174 / 117 12.8 SE010U140500800 5 14 12.35 / 0.49 230 / 154 15.2 SE010U160700800 7 16 12.37 / 0.49 225 / 151 11.2 SE010U140700800 7 14 13.36 / 0.53 287 / 193 13.3 SE010U161000800 10 16 15.67 / 0.62 325 / 218 11.2 SE010U141000800 10 14 16.99 / 0.67 413 / 277 13.3 SE010U161200800 12 16 16.13 / 0.63 363 / 244 11.2 SE010U141200800 12 14 17.5 / 0.69 465 / 313 13.3 *Ampacity value based on National Electrical Code, Version 2011, Table 3-10.15(B)(16). Values are corrected according to Table 310.15(B)(16) for number of Conductors. 1 800 668 4842 shawflex.com Please note: Although the content used for this brochure has been produced and processed from sources believed to be reliable, no warranty, expressed or implied, is made regarding accuracy, adequacy, completeness, legality, reliability or usefulness of any information MARINE V.2 | 17 AWG IEC ARMOURED POWER & CONTROL | SINGLE CONDUCTOR (600/1000V) PAGE 1 OF 1 ShawFlex IEC Armoured Power and Control cables are suitable for use in offshore oil and gas, shipboard and marine applications. Our cables are made to IEC specifications and can be modified to fit your specific requirements. Voltage Certifications/Compliances 600/1000V • IEC 60092-350 • IEC 60754-1 • IEC 61034-1&2 • IEC 60228 Class 5 IEC 60092-353, Control & Power • IEC 60092-376, Instrumentation • IEC 60332-3-22, Category A Flame Propagate Testing • Lloyd’s Register • American Bureau of Shipping • Transport Canada • RoHS Compliant • UV sunlight resistant “SUNRES” (all colours) • - 40°C cold bend rated • - 35°C cold impact rated Product Construction • Insulation: - XLPE (RW90 rated) rated: 90°C wet/dry, 60092-351 • Armour: - Tinned copper braid (optional) - Bronze braid (optional) Jacket: - LSZH Thermoplastic, black (standard) rated: 75°C , SHF1 IEC 60092-359 • Available in: - Custom insulation/jacket colours Colour Coding • 2C – Brown, blue • 3C – Brown, black, grey • 4C – Brown, black, grey, blue • 5C & higher– Black # Coded Cross Section (AWG/MCM) Nominal OD Overall Cable (in/mm) 1 2 3 5 6 1. High Strand Bare Copper Conductors (Tinned Available) 2. Halogen Free XLPE (RW90 Rated) Insulated Conductors 3. Polypropylene Fillers 4. Polyester Separator Tape 5. Tinned Copper Braided Armour 6. Protective LSZH Jacket Cable Weight (lbs/1000ft)/(kg/km) Ampacity (45°C ambient) Part Number Number of Conductors SEB10U0601158N9 1 6 10.146 / 0.4 272 / 183 85 SEB10U0401158N9 1 4 11.848 / 0.47 385 / 259 114 SEB10U1602158N9 2 16 10.476 / 0.41 188 / 127 20 *Ampacity value based on National Electrical Code, Version 2011, Table 3-10.15(B)(16). Values are corrected according to Table 310.15(B)(16) for number of Conductors. 1 800 668 4842 shawflex.com Please note: Although the content used for this brochure has been produced and processed from sources believed to be reliable, no warranty, expressed or implied, is made regarding accuracy, adequacy, completeness, legality, reliability or usefulness of any information MARINE V.2 | 18 AWG IEC ARMOURED POWER & CONTROL | MULTI-CONDUCTOR (600/1000V) PAGE 1 OF 1 ShawFlex IEC Armoured Power and Control cables are suitable for use in offshore oil and gas, shipboard and marine applications. Our cables are made to IEC specifications and can be modified to fit your specific requirements. Voltage Certifications/Compliances 600/1000V • IEC 60092-350 • IEC 60754-1 • IEC 61034-1&2 • IEC 60228 Class 5 IEC 60092-353, Control & Power • IEC 60092-376, Instrumentation • IEC 60332-3-22, Category A Flame Propagate Testing • Lloyd’s Register • American Bureau of Shipping • Transport Canada • RoHS Compliant • UV sunlight resistant “SUNRES” (all colours) • - 40°C cold bend rated • - 35°C cold impact rated Product Construction • Insulation: - XLPE (RW90 rated) rated: 90°C wet/dry, 60092-351 • Armour: - Tinned copper braid (optional) - Bronze braid (optional) Jacket: - LSZH Thermoplastic, black (standard) rated: 75°C , SHF1 IEC 60092-359 • Available in: - Custom insulation/jacket colours 4 1 2 3 5 6 7 1. High Strand Bare Copper Conductors (Tinned Available) 2. Halogen Free XLPE (RW90 Rated) Insulated Conductors 3. Polypropylene Fillers 4. Fiberglass Tape 5. Polyester Separator Tape 6. Tinned Copper Braided Armour 7. Protective LSZH Jacket Colour Coding • 2C – Brown, blue • 3C – Brown, black, grey • 4C – Brown, black, grey, blue • 5C & higher– Black # Coded Part Number Number of Conductors Cross Section (AWG/MCM) Nominal OD Overall Cable (in/mm) Cable Weight (lbs/1000ft)/(kg/km) Ampacity (45°C ambient) SEB10U1602158N9 2 16 10.476 / 0.41 188 / 127 20 SEB10U1402158N9 2 14 11.492 / 0.45 229 / 154 22 SEB10U1202158N9 2 12 12.457 / 0.49 275 / 185 30 SEB10U1002158N9 2 10 13.727 / 0.54 341 / 229 39 SEB10U0802158N9 2 8 15.556 / 0.61 454 / 305 54 SEB10U0602158N9 2 6 17.182 / 0.68 581 / 390 73 SEB10U0402158N9 2 4 20.331 / 0.8 827 / 556 97 SEB10U1603158N9 3 16 10.933 / 0.43 212 / 143 16 SEB10U1403158N9 3 14 12.008 / 0.47 261 / 176 19 SEB10U1203158N9 3 12 13.044 / 0.51 323 / 217 24 SEB10U1003158N9 3 10 14.41 / 0.57 409 / 275 33 SEB10U0803158N9 3 8 16.356 / 0.64 555 / 373 44 SEB10U0603158N9 3 6 18.104 / 0.71 726 / 488 59 SEB10U0403158N9 3 4 21.469 / 0.85 1053 / 708 80 SEB10U1604158N9 4 16 11.98 / 0.47 249 / 167 16 SEB10U1404158N9 4 14 12.897 / 0.51 305 / 205 19 SEB10U1204158N9 4 12 14.06 / 0.55 379 / 255 24 SEB10U1004158N9 4 10 15.846 / 0.62 506 / 340 33 SEB10U0804158N9 4 8 17.743 / 0.7 674 / 453 44 SEB10U0604158N9 4 6 19.955 / 0.79 919 / 617 59 *Ampacity value based on National Electrical Code, Version 2011, Table 3-10.15(B)(16). Values are corrected according to Table 310.15(B)(16) for number of Conductors. 1 800 668 4842 shawflex.com Please note: Although the content used for this brochure has been produced and processed from sources believed to be reliable, no warranty, expressed or implied, is made regarding accuracy, adequacy, completeness, legality, reliability or usefulness of any information MARINE V.2 | 19 AWG IEC ARMOURED POWER & CONTROL | MULTI-CONDUCTOR (600/1000V) PAGE 1 OF 2 Part Number Number of Conductors Cross Section (AWG/MCM) Nominal OD Overall Cable (in/mm) Cable Weight (lbs/1000ft)/(kg/km) Ampacity (45°C ambient) SEB10U0404158N9 4 4 23.697 / 0.93 1341 / 901 80 SEB10U1605158N9 5 16 12.864 / 0.51 284 / 191 12.8 SEB10U1405158N9 5 14 13.892 / 0.55 354 / 238 15.2 SEB10U1607158N9 7 16 13.778 / 0.54 335 / 225 11.2 SEB10U1407158N9 7 14 15.175 / 0.6 427 / 287 13.3 SEB10U1610158N9 10 16 17.08 / 0.67 465 / 312 11.2 SEB10U1410158N9 10 14 18.858 / 0.74 594 / 399 13.3 SEB10U1612158N9 12 16 17.537 / 0.69 508 / 341 11.2 SEB10U1412158N9 12 14 19.374 / 0.76 654 / 439 13.3 *Ampacity value based on National Electrical Code, Version 2011, Table 3-10.15(B)(16). Values are corrected according to Table 310.15(B)(16) for number of Conductors. 1 800 668 4842 shawflex.com Please note: Although the content used for this brochure has been produced and processed from sources believed to be reliable, no warranty, expressed or implied, is made regarding accuracy, adequacy, completeness, legality, reliability or usefulness of any information MARINE AWG V.2 | 20 IEEE 1580 INSTRUMENTATION | PAIRS & TRIADS (300V) PAGE 1 OF 1 ShawFlex IEEE 1580 Instrumentation cables are suitable for use in offshore oil and gas, shipboard and marine applications. Our cables are made to IEC specifications and can be modified to fit your specific requirements. Voltage Certifications/Compliances 300V • IEEE 1580 • ASTM B8 (conductors) • CSA FT4, Vertical Tray Flame Test rated • IEC 60332-3-22, Category A Flame Propagate Testing • American Bureau of Shipping • Transport Canada • RoHS Compliant • UV sunlight resistant “SUN RES” (all colours) • - 40°C cold bend rated • - 35°C cold impact rated Product Construction • Insulation: -XLPE • Armour: - Tinned copper braid (optional) - Bronze braid (optional) • Jacket: - FR PVC Outer Black Jacket rated: 90°C (194°F) to -40°C (40°F) • Available in: - Custom insulation/jacket colours 4 1 1. 2. 3. 4. 5. 2 3 5 6 Bare or tinned copper conductors XLPE Insulated Conductors Polypropylene Fillers Polyester Separator Tape Protective FR PVC Jacket Colour Coding • Pairs - Black, white, # coded • Triads - Black, white,red, # coded ShawFlex can manufacture up to 50 components in 0.75mm2, 1.5mm2, and 2.5mm2 Part Number Number of Pairs/Triads Cross Section (AWG/MCM) Nominal OD Overall Cable (in/mm) Cable Weight (lbs/1000ft)/(kg/km) Ampacity (30°C ambient) SX021M180100000 1PR 18 7.7 / 0.3 73 / 49 11 SX022M180200000 2PR 18 12 / 0.47 156 / 105 14 SX022M180400000 4PR 18 14.7 / 0.58 260 / 175 12 SX022M180800000 8PR 18 18.8 / 0.74 418 / 281 9 SX022M181200000 12PR 18 23.7 / 0.93 644 / 433 8 SX022M181600000 16PR 18 26.2 / 1.03 796 / 535 7 SX022M182400000 24PR 18 32.1 / 1.27 1147 / 771 6 SX021M160100000 1PR 16 8.3 / 0.33 91 / 61 15 SX022M160200000 2PR 16 13.1 / 0.52 194 / 131 18 SX022M160400000 4PR 16 16 / 0.63 330 / 222 16 SX022M160800000 8PR 16 20.6 / 0.81 550 / 369 12 SX022M161200000 12PR 16 25.9 / 1.02 839 / 564 10 SX022M161600000 16PR 16 28.8 / 1.13 1052 / 707 9 SX022M162400000 24PR 16 35.4 / 1.4 1531 / 1028 8 SX031M180100000 1TRD 18 8.1 / 0.32 88 / 59 17 SX032M180200000 2TRD 18 13.3 / 0.53 197 / 132 14 SX032M180400000 4TRD 18 16.3 / 0.64 330 / 222 9 SX032M180800000 8TRD 18 20.9 / 0.82 545 / 366 8 SX031M160100000 1TRD 16 8.7 / 0.34 111 / 75 23 SX032M160200000 2TRD 16 15.4 / 0.61 279 / 187 18 SX032M160400000 4TRD 16 17.8 / 0.7 425 / 285 12 SX032M160800000 8TRD 16 24 / 0.95 788 / 530 10 *Ampacity value based on National Electrical Code, Version 2011, Table 3-10.15(B)(16). Values are corrected according to Table 310.15(B)(16) for number of Conductors. 1 800 668 4842 shawflex.com Please note: Although the content used for this brochure has been produced and processed from sources believed to be reliable, no warranty, expressed or implied, is made regarding accuracy, adequacy, completeness, legality, reliability or usefulness of any information MARINE V.2 | 21 AWG IEEE 1580 CONTROL | SINGLE CONDUCTOR (600/1000V) PAGE 1 OF 1 ShawFlex IEEE 1580 Control cables are suitable for use in offshore oil and gas, shipboard and marine applications. Our cables are made to IEC specifications and can be modified to fit your specific requirements. Voltage Certifications/Compliances 600/1000V • IEEE 1580 • ASTM B8 (conductors) • CSA FT4, Vertical Tray Flame Test rated • IEC 60332-3-22, Category A Flame Propagate Testing • American Bureau of Shipping • Transport Canada • RoHS Compliant • UV sunlight resistant “SUN RES” (all colours) • - 40°C cold bend rated • - 35°C cold impact rated Product Construction • Insulation: - Halogen Free XLPE (RW90 rated) • Jacket: - FR PVC Outer Black Jacket rated: 90°C (194°F) to -40°C (40°F) • Available in: - Custom insulation/jacket colours 1 2 3 1. High Strand Bare Copper Conductors (Tinned Available) 2. Halogen Free XLPE (RW90 Rated) Insulated Conductors 3. FR PVC Outer Protective Jacket Colour Coding • Black conductors (standard) Part Number Number of Conductors Cross Section (AWG/MCM)) Nominal OD Overall Cable (in/mm) Cable Weight (lbs/1000ft)/(kg/km) Ampacity (30°C ambient) SY010M160100000 1 16 5.6 / 0.22 48 / 32 18 SY010M140100000 1 14 6 / 0.24 57 / 39 29 SY010M120100000 1 12 6.4 / 0.25 73 / 49 36 SY010M100100000 1 10 7.1 / 0.28 97 / 65 46 SY010M080100000 1 8 8.6 / 0.34 144 / 97 60 SY010M060100000 1 6 9.5 / 0.37 199 / 134 79 SY010M040100000 1 4 10.7 / 0.42 285 / 191 101 SY010M020100000 1 2 12.2 / 0.48 416 / 279 137 SY010M010140000 1 1 14.4 / 0.57 545 / 366 161 SY010M1/0140000 1 1/0 15.4 / 0.61 661 / 444 183 SY010M2/0140000 1 2/0 16.5 / 0.65 804 / 540 233 SY010M3/0140000 1 3/0 17.8 / 0.7 983 / 661 245 SY010M4/0140000 1 4/0 19.3 / 0.76 1206 / 811 284 SY010M250160000 1 250 20.9 / 0.82 1421 / 955 316 SY010M350160000 1 350 24.6 / 0.97 1986 / 1334 387 SY010M500160000 1 500 27.8 / 1.1 2740 / 1841 479 SY010M750160000 1 750 33.1 / 1.3 4028 / 2707 602 *Ampacity value based on National Electrical Code, Version 2011, Table 3-10.15(B)(16). Values are corrected according to Table 310.15(B)(16) for number of Conductors. 1 800 668 4842 shawflex.com Please note: Although the content used for this brochure has been produced and processed from sources believed to be reliable, no warranty, expressed or implied, is made regarding accuracy, adequacy, completeness, legality, reliability or usefulness of any information MARINE AWG V.2 | 22 IEEE 1580 CONTROL | MULTI-CONDUCTOR (600V/1000V) PAGE 1 OF 1 ShawFlex IEEE 1580 Control cables are suitable for use in offshore oil and gas, shipboard and marine applications. Our cables are made to IEC specifications and can be modified to fit your specific requirements. Voltage Certifications/Compliances 600/1000V • IEEE 1580 • ASTM B8 (conductors) • CSA FT4, Vertical Tray Flame Test rated • IEC 60332-3-22, Category A Flame Propagate Testing • American Bureau of Shipping • Transport Canada • RoHS Compliant • UV sunlight resistant “SUN RES” (all colours) • - 40°C cold bend rated • - 35°C cold impact rated Product Construction • Insulation: -XLPE Armour: - Tinned copper braid (optional) - Bronze braid (optional) • Jacket: - FR PVC Inner/Outer Black Jacket rated: 90°C (194°F) to -40°C (40°F) • Available in: - Custom insulation/jacket colours Colour Coding 4 1 1. 2. 3. 4. 5. 2 3 5 6 Bare Copper Conductors (Tinned Available) XLPE Insulated Conductors Polypropylene Fillers Polyester Separator Tape Protective PVC Jacket • As per IEEE 1580 Table 22 ShawFlex can manufacture up to 50 conductors in 0.75mm2, 1.5mm2, and 2.5mm2 Part Number Number of Conductors Cross Section (AWG/MCM) Nominal OD Overall Cable (in/mm) Cable Weight (lbs/1000ft)/(kg/km) Ampacity (30°C ambient) SY010M160200000 2 16 SY010M140200000 2 14 8.8 / 0.35 96 / 64 15 9.5 / 0.37 117 / 78 24 SY010M120200000 2 SY010M100200000 2 12 10.4 / 0.41 151 / 102 29 10 11.6 / 0.46 203 / 137 38 SY010M080200000 SY010M060200000 2 8 15.4 / 0.61 339 / 228 48 2 6 17.3 / 0.68 460 / 309 65 SY010M040200000 2 4 19.7 / 0.77 653 / 439 83 SY010M020200000 2 2 23.6 / 0.93 1006 / 676 111 SY010M010240000 2 1 26.6 / 1.05 1249 / 839 131 SY010M1/0240000 2 1/0 28.7 / 1.13 1512 / 1016 150 SY010M2/0240000 2 2/0 30.8 / 1.21 1831 / 1230 173 SY010M3/0240000 2 3/0 33.4 / 1.32 2230 / 1499 201 SY010M4/0240000 2 4/0 36.3 / 1.43 2728 / 1833 232 SY010M250260000 2 250 39.6 / 1.56 3179 / 2136 259 SY010M350260000 2 350 46.4 / 1.83 4454 / 2993 317 SY010M500260000 2 500 52.9 / 2.08 6101 / 4100 393 SY010M750260000 2 750 63.5 / 2.5 8945 / 6011 494 SY010M160300000 3 16 9.3 / 0.36 117 / 79 23 SY010M140300000 3 14 10 / 0.39 145 / 97 26 SY010M120300000 3 12 10.9 / 0.43 194 / 131 35 SY010M100300000 3 10 12.3 / 0.48 266 / 178 47 SY010M080300000 3 8 16.3 / 0.64 442 / 297 64 SY010M060300000 3 6 18.3 / 0.72 611 / 411 85 *Ampacity value based on National Electrical Code, Version 2011, Table 3-10.15(B)(16). Values are corrected according to Table 310.15(B)(16) for number of Conductors. 1 800 668 4842 shawflex.com Please note: Although the content used for this brochure has been produced and processed from sources believed to be reliable, no warranty, expressed or implied, is made regarding accuracy, adequacy, completeness, legality, reliability or usefulness of any information MARINE V.2 | 23 AWG IEEE 1580 CONTROL | MULTI-CONDUCTOR (600V/1000V) PAGE 1 OF 1 Part Number Number of Conductors Cross Section (AWG/MCM) Nominal OD Overall Cable (in/mm) Cable Weight (lbs/1000ft)/(kg/km) Ampacity (30°C ambient) SY010M040300000 3 4 20.9 / 0.82 883 / 593 114 SY010M020300000 3 2 25.1 / 0.99 1353 / 909 152 SY010M010340000 3 1 28.3 / 1.11 1693 / 1138 176 SY010M1/0340000 3 1/0 30.5 / 1.2 2068 / 1390 204 SY010M2/0340000 3 2/0 32.8 / 1.29 2515 / 1690 235 SY010M3/0340000 3 3/0 35.6 / 1.4 3082 / 2071 272 SY010M4/0340000 3 4/0 38.7 / 1.52 3784 / 2542 315 SY010M250360000 3 250 42.3 / 1.66 4423 / 2972 357 SY010M350360000 3 350 49.4 / 1.95 6181 / 4154 432 SY010M500360000 3 500 56.4 / 2.22 8537 / 5736 541 SY010M750360000 3 750 67.8 / 2.67 12588 / 8459 667 SY010M160400000 4 16 10 / 0.4 137 / 92 18 SY010M140400000 4 14 10.8 / 0.43 179 / 121 21 SY010M120400000 4 12 11.9 / 0.47 239 / 161 28 SY010M100400000 4 10 13.5 / 0.53 337 / 226 38 SY010M080400000 4 8 17.8 / 0.7 552 / 371 51 SY010M060400000 4 6 20.1 / 0.79 774 / 520 68 SY010M040400000 4 4 24 / 0.95 1188 / 798 91 SY010M020400000 4 2 27.6 / 1.08 1742 / 1170 122 SY010M160500000 5 16 10.9 / 0.43 164 / 110 18 SY010M140500000 5 14 11.8 / 0.47 210 / 141 21 SY010M160600000 6 16 11.8 / 0.47 192 / 129 18 SY010M140600000 6 14 12.8 / 0.51 247 / 166 21 SY010M160800000 8 16 12.8 / 0.5 238 / 160 16 SY010M140800000 8 14 14.6 / 0.58 333 / 224 18 SY010M161200000 12 16 16.1 / 0.63 364 / 245 12 SY010M141200000 12 14 17.5 / 0.69 468 / 315 13 SY010M162400000 24 16 22.9 / 0.9 719 / 483 10 SY010M142400000 24 14 25 / 0.99 933 / 627 12 *Ampacity value based on National Electrical Code, Version 2011, Table 3-10.15(B)(16). Values are corrected according to Table 310.15(B)(16) for number of Conductors. 1 800 668 4842 shawflex.com Please note: Although the content used for this brochure has been produced and processed from sources believed to be reliable, no warranty, expressed or implied, is made regarding accuracy, adequacy, completeness, legality, reliability or usefulness of any information Head Office ShawFlex A division of ShawCor Inc. 25 Bethridge Rd. Toronto, ON M9W 1M7, Canada Tel: +1 416 743 7111 For additional information, please contact: info@shawflex.com or call toll free: 1 800 668 4842 ShawFlex is registered to ISO 9001:2008 1 800 668 4842 shawflex.com Please note: Although the content used for this brochure has been produced and processed from sources believed to be reliable, no warranty, expressed or implied, is made regarding accuracy, adequacy, completeness, legality, reliability or usefulness of any information
Similar documents
High Voltage Cables
our products are tailored to meet the customer’s requirements. Our company has been at the cutting edge of high voltage cable technology for several decades. We have experience in supplying all typ...
More information