Ceramic Log 14 24 15 25

Transcription

Ceramic Log 14 24 15 25
Technical Specification Bulletin Number TB184
Fuel Type
Gas
Date of Issue
Ed i t i o n
Jan 2006
1
Ceramic Log Effect Fitting H & S 14,15 & 24,25
Page Number 1
Installation of the Gas Log Effect
If any of the components of the log effect or burner are broken DO NOT INSTALL . Contact your stove
supplier for replacements. The log effect kit is not covered by the stove`s warranty for accidental
damage, so great care should be taken when handling the ceramic burner and logs. It is important
that the logs and ember fibres are installed in accordance with these instructions as any deviation
may cause poor combustion. The addition of further ceramic logs or coals is strictly prohibited.
Back Log
Identified by one round hole and one slot,
which locate the log on the ceramic burner
base.
Left Hand Log
Identified by the
knot on one side.
Right Hand Log
Identified by the
“V” at one end.
Slot must locate
onto tongue
Front Log
Identified by the one
round hole which
locates the log on the
ceramic burner base.
Euroheat Distributors (HBS) Ltd., Unit 2, Court Farm Business Park, Bishops Frome, Worcestershire, WR6 5AY United Kingdom
Telephone Technical Support 01885 491117 Facsimile 01885 491101 Reception 01885 491100
Email tech@euroheat.co.uk Wed Site sales www.euroheat co.uk
Latest Technical Information www.euroheat.co.uk/support
Technical Specification Bulletin Number TB184
Fuel Type
Gas
Date of Issue
Ed i t i o n
Jan 2006
1
Ceramic Log Effect Fitting H & S 14,15 & 24,25
Page Number 2
Placement of the Ember Glow Fibres
Platinum ember glow fibres are made from high grade ceramic wool. The wool is similar to fibreglass
and should be handled carefully. We recommend the use of suitable dust mask, gloves or tweezers
when placing the embers in position. Wash hands immediately after touching to avoid irritation. Do
not store the embers close to flammable liquids.
The embers must be placed correctly
in order to function properly. Tease
out the fabric to form loose, irregular
shapes.
Do not compress the embers or
force into position.
Important:
Tease out fabric to form
loose, irregular shapes.
Use of embers
With the embers correctly placed they glow and flicker similar to glowing ash. Their placement is
important as the effect produced can only occur when they are heated by the gas jets or by direct
radiant heat. Once placed small movements of the embers location can improve the effect.
By rubbing embers into the faces of the logs which are heated by the gas jets, the fibres which
adhere to the logs will glow. With suitable gloves take a square of ember glow and gently rub the
material into the area`s of logs which glow when in operation (see the log fitting instructions which
follow).
The pack containing the ember glow fibres contains more than required.
The additional embers should be kept for further service requirements.
Euroheat Distributors (HBS) Ltd., Unit 2, Court Farm Business Park, Bishops Frome, Worcestershire, WR6 5AY United Kingdom
Telephone Technical Support 01885 491117 Facsimile 01885 491101 Reception 01885 491100
Email tech@euroheat.co.uk Wed Site sales www.euroheat co.uk
Latest Technical Information www.euroheat.co.uk/support
Technical Specification Bulletin Number TB184
Fuel Type
Gas
Date of Issue
Ed i t i o n
Jan 2006
1
Ceramic Log Effect Fitting H & S 14,15 & 24,25
Page Number 3
Ember Glow Fibres Placement
To left side of burner jets
In front of burner jets
To right side of
burner jets
Over burner jets
1. Fit the largest log with the hole and slot in the base corresponding to the peg and tongue at the
back of the ceramic burner, ensuring that the peg goes into the hole on the log and the tongue
goes into the slot. Place 2-3 pieces of ember glow fibres (A) just to the left hand side of the burner
jets. Place 3-4 pieces of ember glow fibres (B) just to the right hand side of the burner jets. Place
6-7 ember glow fibres (C) just in front of the burner jets. Note: if placed over the burner jets, flame
height will be greatly reduced.
(A)
Position
of 2-3
embers
Rub ember glow
into the surface
of the burnt
section
(B)
Position
of 3-4
embers
(D)
Position
6-7
embers
Euroheat Distributors (HBS) Ltd., Unit 2, Court Farm Business Park, Bishops Frome, Worcestershire, WR6 5AY United Kingdom
Telephone Technical Support 01885 491117 Facsimile 01885 491101 Reception 01885 491100
Email tech@euroheat.co.uk Wed Site sales www.euroheat co.uk
Latest Technical Information www.euroheat.co.uk/support
Technical Specification Bulletin Number TB184
Fuel Type
Gas
Date of Issue
Ed i t i o n
Jan 2006
1
Ceramic Log Effect Fitting H & S 14,15 & 24,25
Page Number 4
2. Fit the second largest log with the one hole in the base locating it on the peg in the middle of
the ceramic burner. Place 6-7 ember glow fibres (D) just in front of the burner jets.
Rub ember glow
into the surface
of the burnt
section
(D)
Position 6-7
embers
3. Fit the right hand log (E) with the “V” corresponding to the two indentations, in the burner base
at the right hand end of the front log. The other end of the log resting upon the back log. Fit the
left hand log (F) with the knot corresponding to the indentations, at the left hand end of the front
log. The other end of the log resting upon the back log.
(F)
(E)
Euroheat Distributors (HBS) Ltd., Unit 2, Court Farm Business Park, Bishops Frome, Worcestershire, WR6 5AY United Kingdom
Telephone Technical Support 01885 491117 Facsimile 01885 491101 Reception 01885 491100
Email tech@euroheat.co.uk Wed Site sales www.euroheat co.uk
Latest Technical Information www.euroheat.co.uk/support