Ceramic Log 34 35 44 45 Technical Bulletin Fitting

Transcription

Ceramic Log 34 35 44 45 Technical Bulletin Fitting
Technical Specification Bulletin Number TB186
Fuel Type
Gas
Date of Issue
Ed i t i o n
Feb 2006
1
Ceramic Log Effect Fitting H & S 34,35 & 44,45
Page Number 1
Installation of the Gas Log Effect
If any of the components of the log effect or burner are broken DO NOT INSTALL. Contact your
stove supplier for replacements. The log effect kit is not covered by the stove`s warranty for
accidental damage, so great care should be taken when handling the ceramic burner and logs. It
is important that the logs, ember glow fibres and ceramic cubes are installed in accordance with
these instructions as any deviation may cause poor combustion. The addition of further ceramic
logs or cubes is strictly prohibited.
Burner and log set components
Back Log
Ceramic Burner
Left Log
Ceramic cubes
Front Log
1 gram bag ember glow fibre
Ember
Glow
Fibre
Euroheat Distributors (HBS) Ltd., Unit 2, Court Farm Business Park, Bishops Frome, Worcestershire, WR6 5AY United Kingdom
Telephone Technical Support 01885 491117 Facsimile 01885 491101 Reception 01885 491100
Email tech@euroheat.co.uk Wed Site sales www.euroheat co.uk
Latest Technical Information www.euroheat.co.uk/support
Technical Specification Bulletin Number TB186
Fuel Type
Gas
Date of Issue
Ed i t i o n
Feb 2006
1
Ceramic Log Effect Fitting H & S 34,35 & 44,45
Page Number 2
Placement of the Ember Glow Fibres
Platinum Ember fibres are made from high grade ceramic wool. The wool is coated with platinum
and is similar to fibreglass and should be handled carefully. We recommend the use of suitable
dust mask, gloves or tweezers when placing the embers in position. Wash hands immediately after
touching to avoid irritation. Do not store the embers close to flammable liquids.
The Embers must be placed correctly in
order to function properly. Tease out the
fabric to form loose, irregular shapes.
Do not compress the embers or force
into position.
Important:
Tease out fabric to form
loose, irregular shapes.
Use of ember glow fibres
With the embers correctly placed the fibres glow and flicker similar to burning ash. Their placement
is important as the effect produced can only occur when they are heated by the gas jets or by direct
radiated heat. Place the ember fibres under the small cubes to hold the ember fibres in place.
By rubbing ember glow fibres into the face of the logs which are heated by the gas jets, the fibres
which adhere to the logs will flicker and glow. With suitable gloves take a square of ember glow
fibre and gently rub into the burnt area of each log. (see the log fitting instructions which follow).
The pack containing the ember glow fibres contains more than is required.
The additional embers should be kept for further service requirements.
Euroheat Distributors (HBS) Ltd., Unit 2, Court Farm Business Park, Bishops Frome, Worcestershire, WR6 5AY United Kingdom
Telephone Technical Support 01885 491117 Facsimile 01885 491101 Reception 01885 491100
Email tech@euroheat.co.uk Wed Site sales www.euroheat co.uk
Latest Technical Information www.euroheat.co.uk/support
Technical Specification Bulletin Number TB186
Fuel Type
Gas
Date of Issue
Ed i t i o n
Feb 2006
1
Ceramic Log Effect Fitting H & S 34,35 & 44,45
Page Number 3
Pilot Ignition Route
Do not cover pilot
ignition route holes
with either ceramic
cubes or ember fibres.
Place fibres and cubes
adjacent to this area.
Fitting the Log Effect Kit
This is very fragile and should be handled with the utmost care. Ensure that all transport packaging
which held the ceramic burner in place in transit has been removed.
Position the main log at the rear of the burner, so that the flat surfaces of the rear log and burner
sit together.
1.
Place ceramic cubes adjacent to the holes of the burner underneath the rear log with teased
out sections of ember glow under each ember cube, leaving about 5mm between each cube. Do
not place ceramic cubes or ember glow on the pilot ignition route (see previous page) Gently rub
the ember glow into the burnt surfaces of the log.
Euroheat Distributors (HBS) Ltd., Unit 2, Court Farm Business Park, Bishops Frome, Worcestershire, WR6 5AY United Kingdom
Telephone Technical Support 01885 491117 Facsimile 01885 491101 Reception 01885 491100
Email tech@euroheat.co.uk Wed Site sales www.euroheat co.uk
Latest Technical Information www.euroheat.co.uk/support
Technical Specification Bulletin Number TB186
Fuel Type
Gas
Date of Issue
Ed i t i o n
Feb 2006
1
Ceramic Log Effect Fitting H & S 34,35 & 44,45
Page Number 4
2
. Fit the left hand log with the larger end on the burner and the smaller end against the rear
log. There is a small groove next to the left circular secondary air hole. The left log has a chamfered
edge which should be located into this groove. Gentle rub the ember glow into the burnt surfaces
of the log.
Left log fits into groove
in burner surface
3.
Before you fit the front log.
Place ceramic cubes adjacent to the holes of the burner in front of and to the sides of the left hand
log, with teased out sections of ember glow under each ember cube, leaving about 5mm between
each cube.
Euroheat Distributors (HBS) Ltd., Unit 2, Court Farm Business Park, Bishops Frome, Worcestershire, WR6 5AY United Kingdom
Telephone Technical Support 01885 491117 Facsimile 01885 491101 Reception 01885 491100
Email tech@euroheat.co.uk Wed Site sales www.euroheat co.uk
Latest Technical Information www.euroheat.co.uk/support
Technical Specification Bulletin Number TB186
Fuel Type
Gas
Date of Issue
Ed i t i o n
Feb 2006
1
Ceramic Log Effect Fitting H & S 34,35 & 44,45
Page Number 5
4
Place the front log in the front locating slot in the burner surface, then lean the log against the
left log. The ceramic cubes may have to be adjusted to allow the front log to sit correctly.
When the appliance is first fired small adjustments to the ceramic cubes and ember glow can be
made to achieve the desired effect.
Euroheat Distributors (HBS) Ltd., Unit 2, Court Farm Business Park, Bishops Frome, Worcestershire, WR6 5AY United Kingdom
Telephone Technical Support 01885 491117 Facsimile 01885 491101 Reception 01885 491100
Email tech@euroheat.co.uk Wed Site sales www.euroheat co.uk
Latest Technical Information www.euroheat.co.uk/support
Technical Specification Bulletin Number TB186
Fuel Type
Gas
Date of Issue
Ed i t i o n
Feb 2006
1
Ceramic Log Effect Fitting H & S 34,35 & 44,45
Page Number 6
Burner and Log Assembly Complete
The ceramic log effect burner should NOT be used if damaged in anyway.
Do not be tempted to try to mend the ceramic log effect burner, always replace it.
The ceramic log effect burner sits lightly on top of the gas input venturi tube, do not push
Euroheat Distributors (HBS) Ltd., Unit 2, Court Farm Business Park, Bishops Frome, Worcestershire, WR6 5AY United Kingdom
Telephone Technical Support 01885 491117 Facsimile 01885 491101 Reception 01885 491100
Email tech@euroheat.co.uk Wed Site sales www.euroheat co.uk
Latest Technical Information www.euroheat.co.uk/support