ioPAC 8600 Series

Transcription

ioPAC 8600 Series
Programmable RTU Controllers
ioPAC 8600 Series
Rugged modular RTU controllers
››Modular CPU/PWR/Backplane/IO design supporting ioPAC
8500/8600 series I/O modules
››Supports dual power module with dual power input
››Supports C/C++ and IEC 61131-3 programming languages, and
ready-to-run services
››Supports 24 to 110 V power input range and DI/O modules
››Compliant with EN 50121-3-2 and EN 50121-4 specifications
Overview
The ioPAC 8600 modular RTU controllers are 100% modular, giving users the freedom to choose CPU, power, backplane, communication, and I/O
modules. In addition, the ioPAC 8600 enhances the hardware system architecture and key features of the ioPAC 8020 and ioPAC 8500 combined. It not
only preserves the dual CPU architecture to support all ioPAC 8600 I/O modules, but also adds an Ethernet bus on the backplane to support Ethernet
switch modules. The ioPAC 8600 supports the C/C++ and IEC 61131-3 programming languages and ready-to-run services, including Modbus, data
logging, and email alarms to fulfill different customers’ requirements. With Moxa’s Active OPC Server and DA-Center data integration software, the
ioPAC 8600 series provides a comprehensive solution for data acquisition and control applications in harsh environments.
2-Wire Ethernet Technology
Moxa’s 2-wire Ethernet technology offers system integrators an
attractive option for upgrading the train’s IP network to a 10/100
Mbps* Ethernet backbone with existing 2-wire cable. This innovative
2-wire Ethernet technology supports Ethernet bypass functionality,
ensuring that the Ethernet backbone will continue to operate even
if one ioPAC is without power. As an added plus, with two 2-wire
Ethernet modules in one ioPAC, the network can reach 200 Mbps and
provide a redundant architecture.
*Network performance is related to cable quality when using 2-wire technology.
Read-to-Run Service
Moxa’s ioPAC 8600 programmable controllers allow programmers
to rapidly configure services (SNMP, Modbus RTU/TCP Master/
Slave, E-mail/SMS alarm service, etc.) without writing any programs.
The ioPAC can reduce the configuration of massively distributed
deployments to a few simple mouse clicks, greatly increasing
engineers’ productivity.
Automatic Carriage Sequencing (ACS)
Moxa’s Automatic Carriage Sequencing technology quickly and
automatically resets the train car sequence, without disrupting network
transmissions within the train. This technology greatly reduces the
operation effort required for trains that frequently rearrange consists.
Onboard passenger information systems can also adjust immediately
when changes are made.
1
w w w. m o x a . c o m
Programmable RTU Controllers
Compact Integrated Solution
The compact ioPAC 8600 is equipped with universal dual-power
inputs that support all railway power voltages, and a new
channel-to-channel, high voltage DI/DO module is available
for use in trains that use different power systems. The ioPAC
8600 supports a variety of communication interfaces, including
Ethernet, serial, CAN*, and MVB*. System integrators can
control or monitor sub-systems with the ioPAC 8600, which
saves space and has powerful functions to reduce both the
system integrators’ budget and installation difficulties.
*CAN and MVB available by project request.
Specifications
Physical Characteristics
Housing: Aluminum
Dimensions:
• 5-slot version: 205.65 x 133.35 x 100 mm (8.1 x 5.25 x 3.94 in)
• 9-slot version: 324.8 x 133.35 x 100 mm (12.79 x 5.25 x 3.94 in)
Mounting: DIN-rail mounting, wall mounting (optional), and rack
mounting (optional)
Environmental Limits
Operating Temperature: -40 to 75°C (-40 to 176°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity: 5 to 95% (non-condensing)
Altitude: Up to 2000 m
Note: Please contact Moxa if you require products guaranteed to function
properly at higher altitudes.
Standards and Certifications
Safety: UL 508
EMI: EN 55022, EN 61000-3-2; EN 61000-3-3; FCC Part 15 Subpart B
Class A
EMS: EN 55024, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN
61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11
Shock: IEC 60068-2-27
Freefall: IEC 60068-2-32
Vibration: IEC 60068-2-6
Rail Traffic: EN 50155*, EN 50121-3-2, EN 50121-4
*Complies with a portion of EN 50155 specifications. Please contact Moxa or a
Moxa distributor for details.
Note: Please check Moxa’s website for the most up-to-date certification status.
Warranty
Warranty Period: 5 years
Details: See www.moxa.com/warranty
Dimensions
133.35 (5.25)
Unit: mm (inch)
ioPAC 8600 with 5 I/O slots
205.65 (8.1)
241.4 (9.5)
133.35 (5.25)
100 (3.94)
ioPAC 8600 with 9 I/O slots
324.8 (12.78)
360.55 (14.19)
100 (3.84)
Mounting Kits
Wall Mounting Kit
(optional)
Wall Mounting Kit
(optional)
DIN-Rail Mounting
Kit (Optional)
2
DIN-Rail Mounting
Kit (Optional)
w w w. m o x a . c o m
Programmable RTU Controllers
Ordering Information
Both ioPAC 8500 modules and ioPAC 8600 modules can be used
with the ioPAC 8600 series. For detailed information about each
module, see pages 4 to 10.
CPU Modules
ioPAC 8600-CPU10-M12-C-T: ioPAC 8600 CPU module with M12 Ethernet connectors, C/C++, -40 to 75°C operating temperature
ioPAC 8600-CPU10-RJ45-C-T: ioPAC 8600 CPU module with RJ45 Ethernet connectors, C/C++, -40 to 75°C operating temperature
ioPAC 8600-CPU10-M12-IEC-T: ioPAC 8600 CPU module with M12 Ethernet connectors, IEC 61131-3, -40 to 75°C operating temperature
ioPAC 8600-CPU10-RJ45-IEC-T: ioPAC 8600 CPU module with RJ45 Ethernet connectors, IEC 61131-3, -40 to 75°C operating temperature
Power Modules
ioPAC 8600-PW10-15W-T: ioPAC 8600 power module with 24 to 110 VDC input, 15 W, -40 to 75°C operating temperature
Backplane Modules
ioPAC 8600-BM005-T: ioPAC 8600 backplane modules with 5 I/O slots, -40 to 75°C operating temperature
ioPAC 8600-BM009-T: ioPAC 8600 backplane modules with 9 I/O slots, -40 to 75°C operating temperature
I/O Modules
86M-1832D-T: ioPAC 8600 I/O module with 8 channel to channel isolated DIs, channel LED, 24 VDC sink/source type, -40 to 75°C operating
temperature
86M-2830D-T: ioPAC 8600 I/O module with 8 channel to channel isolated DOs, channel LED, 24 VDC sink type, -40 to 75°C operating temperature
86M-2604D-T: ioPAC 8600 I/O module with 6 relays, channel LED, form A (N.O.) type, -40 to 75°C operating temperature
86M-4420-T: ioPAC 8600 I/O module with 4 AOs, 0 to 10 V / -10 to 10 V / 0 to 20 mA / 4 to 20 mA, -40 to 75°C operating temperature
85M-1602-T: ioPAC 8500 I/O module with 16 DIs, 24 VDC sink/source type, -40 to 75°C operating temperature
85M-2600-T: ioPAC 8500 I/O module with 16 DOs, 24 VDC sink type, -40 to 75°C operating temperature
85M-3800-T: ioPAC 8500 I/O module with 8 AIs, 4 to 20 mA, -40 to 75°C operating temperature
85M-3810-T: ioPAC 8500 I/O module with 8 AIs, 0 to 10 V, -40 to 75°C operating temperature
85M-3801-T: ioPAC 8500 I/O module with 8 AIs, 4 to 20 mA, 40 kHz, -40 to 75°C operating temperature
85M-3811-T: ioPAC 8500 I/O module with 8 AIs, 0 to 10 V, 40 kHz, -40 to 75°C operating temperature
85M-6600-T: ioPAC 8500 I/O module with 6 RTDs, -40 to 75°C operating temperature
85M-6810-T: ioPAC 8500 I/O module with 8 TCs, -40 to 75°C operating temperature
85M-5401-T: ioPAC 8500 communication module with 4 serial ports (DB44 connectors), -40 to 75°C operating temperature
Optional Accessories (can be purchased separately)
DK-DC50131: Din-rail mounting kit
WK-75: Wall mounting kit
CBL-M12D(MM4P)/RJ45-100 IP67: M12 to RJ45 cable
85M-BKTES: Empty slot cover for ioPAC 8600/8500 modules (3 pcs per package)
Package Checklist
• ioPAC 8600 CPU module
• Serial console cable (C/C++ version only)
• Software CD
Note: Conformal coating available on request
3
w w w. m o x a . c o m
Programmable RTU Controllers
ioPAC 8600 Series Modules
32-bit ARM9 192 MHz CPU
ioPAC 8600-CPU10-M12-IEC-T
CPU Type: 32-bit ARM9 192 MHz CPU
OS: Linux
Clock: Real-time clock with super capacitor
(retains charge for 7 days)
ioPAC 8600 CPU10-IEC
PWR
RDY
R/S
ERR
ioPAC 8600-CPU10 Series: 32-bit ARM9 192 MHz CPU
Computer
Ethernet Interface
SW
Memory
SDRAM: 64 MB
Flash: 32 MB (10 MB reserved for user)
FRAM: 128 KB
microSD™ Slot: Up to 32 GB (SD 2.0 compatible)
RST
P1
Note: For units operating in extreme temperatures, industrial
grade, wide-temperature microSD cards are required.
P2
Switches & Buttons
Rotary Switch: 0 to 9
Button: Reset to factory defaults
LAN: 2 x 10/100 Mbps, Ethernet bypass or 2 MACs (IPs), jumper
selectable, RJ45 or M12
Protection: 1.5 kV magnetic isolation
Automation Languages: C/C++, IEC 61131-3
Protocols: Modbus/TCP Master/Slave, Modbus/RTU Master, Active
OPC
Environmental Limits
Operating Temperature: -40 to 75°C
Power Requirements
Power Consumption: 4.8 W
MTBF (mean time between failures)
Time: 1,132,561 hrs (TBD)
Database: Telcordia (Bellcore)
Dual power input, 24 to 110 VDC, 15 W
ioPAC 8600-PW10-15W-T: Dual power input, 24 to 110 VDC, 15 W
Power
ioPAC 8600
Power Input: 24 to 110 VDC
PW10-15W
PWR
Note: Compliant with EN 50155 at 24/48/60/72/110 VDC
Wattage: 15 W
Galvanic Isolation: 3k VDC
Dual Power Input: Yes
Environmental Limits
Operating Temperature: -40 to 75°C
MTBF (mean time between failures)
V2+
V2 N.C.
V1+
V1 -
4
Time: 1,132,561 hrs (TBD)
Database: Telcordia (Bellcore)
w w w. m o x a . c o m
Programmable RTU Controllers
8 channel to channel isolated DIs, 24 VDC, channel LED, sink/source type
86M-1832D-T: 8 channel to channel isolated DIs, 24 VDC, channel LED, sink/source type
Counter Frequency: 5 kHz
Inputs and Outputs
Digital Inputs: 8 channels
Isolation:
To system: 3k VDC or 2k Vrms
Channel to channel: 1k VDC
Digital Filtering Time Interval: Software selectable (by 0.1 ms)
Digital Inputs
Environmental Limits
Sensor Type: Wet contact (NPN or PNP)
I/O Mode: DI, counter, or frequency mode
Wet Contact:
NPN:
• On: 0 to 3 VDC
• Off: 10 to 30 VDC
PNP:
• Off: 0 to 3 VDC
• On: 10 to 30 VDC
Physical Characteristics
Wiring: I/O cable, max. 16 AWG
Connector: Spring type terminal block
Operating Temperature: -40 to 75°C
Power Requirements
Power Consumption: 0.3 W
MTBF (mean time between failures)
Time: 1,132,561 hrs (TBD)
Database: Telcordia (Bellcore)
8 channel to channel isolated DOs, 24 VDC, channel LED, sink type
86M-2830D-T: 8 channel to channel isolated DOs, 24 VDC, channel LED, sink type
Inputs and Outputs
Physical Characteristics
Digital Outputs: 8 channels
Isolation:
To system: 3k VDC or 2k Vrms
Channel to channel: 1k VDC
Wiring: I/O cable, max. 16 AWG
Connector: Spring type terminal block
Digital Outputs
Power Requirements
Environmental Limits
Operating Temperature: -40 to 75°C
Type: Sink
Power Consumption: 1.8 W (with all DOs on)
I/O Mode: DO or PWM mode
MTBF (mean time between failures)
Pulse Output Frequency: 1 kHz
Time: 792,571 hrs (TBD)
Short Circuit Protection: 750 mA @ 25°C
Database: Telcordia (Bellcore)
Over-voltage Protection: 41 VDC
Over-current Protection: 2.6 A (4 channels @ 650 mA)
Over-temperature Shutdown: 175°C (typical), 150°C (min.)
Current Rating: 200 mA per channel
6 relays, channel LED, form A (N.O.) type
86M-2604D-T: 6 relays, channel LED, form A (N.O.) type
Electrical Endurance: 60,000 operations @ 5 A resistive load
Inputs and Outputs
Relay Outputs: 6 channels
Isolation:
To System: 3k VDC or 2k Vrms
Relay Outputs
Type: Form A (N.O.)
I/O mode: DO or PWM mode
Pulse Output Frequency: 0.33 Hz
Contact Current Rating:
Resistive Load: 5 A @ 30 VDC, 250 VAC
Relay On/Off Time: 10 ms (max.)
Initial Insulation Resistance: 1000 M ohms (min.)
@ 500 VDC
Mechanical Endurance: 5,000,000 operations
5
Contact Resistance: 100 m ohms (max.)
Physical Characteristics
Wiring: I/O cable, max. 16 AWG
Connector: Spring type terminal block
Environmental Limits
Operating Temperature: -40 to 75°C
Power Requirements
Power Consumption: 3 W (with all relays on)
MTBF (mean time between failures)
Time: 1,512,906 hrs (TBD)
Database: Telcordia (Bellcore)
w w w. m o x a . c o m
Programmable RTU Controllers
4 analog outputs, 0 to 10 V or -10 to 10 V or 0 to 20 mA or 4 to 20 mA
86M-4420-T: 4 analog outputs, 0 to 10 V or -10 to 10 V or 0 to 20 mA or 4 to 20 mA
Update Rate: Software polling or waveform mode
Inputs and Outputs
Analog Outputs: 4 channels
Isolation:
To system: 3k VDC or 2k Vrms
Analog Outputs
Resolution: 12 bits
Output range: 0-10 V, -10-10 V, 0-20 mA, 4-20 mA
I/O mode: Static or Waveform mode
Voltage Output: 10 mA (max.)
Accuracy:
±0.1% FSR @ 25°C
±0.3% FSR @ -40 and 75°C
Current Load Resistance:
Internal Power: 400 ohms
External 24 VDC Power: 1000 ohms
6
Wavemode Frequency: 125 Hz
Physical Characteristics
Wiring: I/O cable, max. 16 AWG
Connector: Spring type terminal block
Environmental Limits
Operating Temperature: -40 to 75°C
Power Requirements
Power Consumption:
2.26 W (Voltage)
3.45 W (Current)
MTBF (mean time between failures)
Time: 1,530,690 hrs (TBD)
Database: Telcordia (Bellcore)
w w w. m o x a . c o m
Programmable RTU Controllers
ioPAC 8500 Series Modules
16 digital inputs, 24 VDC, sink/source, dry contact type
85M-1602-T: 16 digital inputs, 24 VDC, sink/source, dry contact type
Common Type: 8 points per COM
Inputs and Outputs
Digital Inputs: 16 channels
Isolation: 3k VDC or 2k Vrms
Digital Inputs
Sensor Type: Wet contact (NPN or PNP), dry contact
I/O Mode: DI or event counter
Dry Contact:
• On: short to GND
• Off: open
Wet Contact (DI to GND):
NPN (DI to GND):
• On: 0 to 3 VDC
• Off: 10 to 30 VDC
PNP (DI to GND):
• Off: 0 to 3 VDC
• On: 10 to 30 VDC
Counter Frequency: 5 kHz
Digital Filtering Time Interval: Software selectable (by 0.1 ms)
Physical Characteristics
Wiring: I/O cable, max. 16 AWG
Connector: Spring type terminal block
Environmental Limits
Operating Temperature: -40 to 75°C
Power Requirements
Power Consumption: 1.2 W @ 3.3 VDC
MTBF (mean time between failures)
Time: 1,132,561 hrs
Database: Telcordia (Bellcore)
16 digital outputs, 24 VDC, sink type
85M-2600-T: 16 digital outputs, 24 VDC, sink type
Inputs and Outputs
Physical Characteristics
Digital Outputs: 16 channels
Isolation: 3k VDC or 2k Vrms
Wiring: I/O cable, max. 16 AWG
Connector: Spring type terminal block
Digital Outputs
Environmental Limits
Type: Sink
I/O Mode: DO or pulse output
Pulse Output Frequency: 5 kHz
Over-voltage Protection: 45 VDC
Over-current Protection: 2.6 A (4 channels @ 650 mA)
Over-temperature Shutdown: 175°C (typical), 150°C (min.)
Current Rating: 200 mA per channel
Operating Temperature: -40 to 75°C
Power Requirements
Power Consumption: 0.85 W @ 3.3 VDC
MTBF (mean time between failures)
Time: 792,571 hrs
Database: Telcordia (Bellcore)
8 analog inputs, 4 to 20 mA
85M-3800-T: 8 analog inputs, 4 to 20 mA
Inputs and Outputs
Physical Characteristics
Analog Inputs
Environmental Limits
Analog Inputs: 8 channels
Isolation: 3k VDC or 2k Vrms
Type: Differential
Resolution: 16 bits
I/O Mode: 4 to 20 mA (wire off)
Accuracy:
±0.1% FSR @ 25°C
±0.3% FSR @ -40 and 75°C
Sampling Rate:
• All channels: 100 samples/sec
• Per channel: 12.5 samples/sec
Input Impedance: 125 ohms (min.)
7
Wiring: I/O cable, max. 16 AWG
Connector: Spring type terminal block
Operating Temperature: -40 to 75°C
Power Requirements
Power Consumption: 1.05 W @ 3.3 VDC
MTBF (mean time between failures)
Time: 1,512,906 hrs
Database: Telcordia (Bellcore)
w w w. m o x a . c o m
Programmable RTU Controllers
8 analog inputs, 0 to 10 VDC
85M-3810-T: 8 analog inputs, 0 to 10 VDC
Inputs and Outputs
Analog Inputs: 8 channels
Isolation: 3k VDC or 2k Vrms
Analog Inputs
Type: Differential
Resolution: 16 bits
I/O Mode: 0 to 10 VDC
Accuracy:
±0.1% FSR @ 25°C
±0.3% FSR @ -40 and 75°C
Sampling Rate:
• All channels: 100 samples/sec
• Per channel: 12.5 samples/sec
Input Impedance: 200 k-ohms (min.)
Physical Characteristics
Wiring: I/O cable, max. 16 AWG
Connector: Spring type terminal block
Environmental Limits
Operating Temperature: -40 to 75°C
Power Requirements
Power Consumption: 1.04 W @ 3.3 VDC
MTBF (mean time between failures)
Time: 1,530,690 hrs
Database: Telcordia (Bellcore)
8 analog inputs, 4 to 20 mA, 40 kHz
85M-3801-T: 8 analog inputs, 4 to 20 mA, 40 kHz
Inputs and Outputs
Input Impedance: 125 ohms (min.)
Analog Inputs: 8 channels
Isolation: 3k VDC or 2k Vrms
Analog Inputs
Type: Differential
Resolution: 16 bits
I/O Mode: 4 to 20 mA (wire off)
Historical Data Buffering: 60KB per channel,
6 seconds data buffer at 5KHz
Accuracy:
±0.1% FSR @ 25°C
±0.3% FSR @ -40 and 75°C
Sampling Rate:
• All channels: 40k samples/sec
• Per channel: 5k samples/sec
Physical Characteristics
Wiring: I/O cable, max. 16 AWG
Connector: Spring type terminal block
Environmental Limits
Operating Temperature: -40 to 75°C
Power Requirements
Power Consumption: 1.25 W @ 3.3 VDC
MTBF (mean time between failures)
Time: 1,410,655 hrs
Database: Telcordia (Bellcore)
8 analog inputs, 0 to 10 VDC, 40 kHz
85M-3811-T: 8 analog inputs, 0 to 10 VDC, 40 kHz
Inputs and Outputs
Physical Characteristics
Analog Inputs: 8 channels
Isolation: 3k VDC or 2k Vrms
Analog Inputs
Type: Differential
Resolution: 16 bits
I/O Mode: 0 to 10 VDC
Historical Data Buffering: 60 KB per channel,
6 seconds data buffer at 5 kHz
Accuracy:
±0.1% FSR @ 25°C
±0.3% FSR @ -40 and 75°C
Sampling Rate:
• All channels: 40k samples/sec
• Per channel: 5k samples/sec
Input Impedance: 20 M-ohms (min.)
8
Wiring: I/O cable, max. 16 AWG
Connector: Spring type terminal block
Environmental Limits
Operating Temperature: -40 to 75°C
Power Requirements
Power Consumption: 1.25 W @ 3.3 VDC
MTBF (mean time between failures)
Time: 1,426,112 hrs
Database: Telcordia (Bellcore)
w w w. m o x a . c o m
Programmable RTU Controllers
6 RTD inputs
85M-6600-T: 6 RTD inputs
Inputs and Outputs
RTD Inputs: 6 channels
Isolation: 3K VDC or 2K Vrms
RTD Inputs
Input Type:
• PT50, PT100, PT200, PT500 (-200 to 850°C)
• PT1000 (-200 to 350°C)
• JPT100, JPT200, JPT500 (-200 to 640°C)
• JPT1000 (-200 to 350°C)
• NI100, NI200, NI500 (-60 to 250°C)
• NI1000 (-60 to 150°C)
• NI120 (-80 to 260°C)
• Resistance of 310, 620, 1250, and 2200
Sampling Rate (single channel):
• All channels: 12 samples/sec
• Per channel: 2 samples/sec
Resolution: 0.1°C or 0.1 ohm
Accuracy:±0.1% FSR @ 25°C
±0.3% FSR @ -40 and 75°C
Input Impedance: 625 kohms (min.)
Physical Characteristics
Wiring: I/O cable, max. 16 AWG
Connector: Spring type terminal block
Environmental Limits
Operating Temperature: -40 to 75°C
8 thermocouple inputs
85M-6810-T: 8 thermocouple inputs
Inputs and Outputs
Analog Inputs: 8 channels
Isolation: 3K VDC or 2K Vrms
Thermocouple Inputs
Sensor Type: J (0 to 750°C), K (-200 to 1250°C),
T (-200 to 350°C), E (-200 to 900°C), R (-50 to
1600°C), S (-50 to 1760°C), B (600 to 1700°C),
N (-200 to 1300°C)
Millivolt Type:
• Mode: ±78.126 mV, ±39.062 mV, ±19.532 mV
• Fault and over-voltage protection: -35 to +35 VDC
(power off); -25 to +30 VDC (power on)
Sampling Rate (single channel):
• All channels: 12 samples/sec
• Per channel: 1.5 samples/sec
Resolution: 16 bits
9
Accuracy:±0.1% FSR @ 25°C
±0.3% FSR @ -40 and 75°C
Input Impedance: 1 Mohms (min.)
Physical Characteristics
Wiring: I/O cable, max. 16 AWG
Connector: Spring type terminal block
Environmental Limits
Operating Temperature: -40 to 75°C
w w w. m o x a . c o m
Programmable RTU Controllers
4 serial ports
85M-5401-T: 4 serial ports
Serial Communication
Interface: 4 RS-232/422/485 ports, software selectable
(DB44 male)
Isolation: 3K VDC or 2K Vrms
Note: DB44 to 4-port DB9 cable included in the package.
Serial Communication Parameters
Parity: None, Even, Odd
Data Bits: 7, 8
Stop Bits: 1, 2
Flow Control: RTS/CTS, XON/XOFF
Baudrate: 300 bps to 921.6 kbps
Physical Characteristics
Connector: DB44 male
Environmental Limits
Operating Temperature: -40 to 75°C
Power Requirements
Power Consumption: 1.24 W @ 3.3 VDC
MTBF (mean time between failures)
Time: 596,611 hrs
Database: Telcordia (Bellcore)
Serial Signals
RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422: Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w: Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w: Data+, Data-, GND
10
© Moxa Inc. All rights reserved. Updated Jul. 27, 2015. Specifications subject to change without notice. Please visit our website for the most up-to-date product information.