ioPAC 8600 Series
Transcription
ioPAC 8600 Series
Programmable RTU Controllers ioPAC 8600 Series Rugged modular RTU controllers ››Modular CPU/PWR/Backplane/IO design supporting ioPAC 8500/8600 series I/O modules ››Supports dual power module with dual power input ››Supports C/C++ and IEC 61131-3 programming languages, and ready-to-run services ››Supports 24 to 110 V power input range and DI/O modules ››Compliant with EN 50121-3-2 and EN 50121-4 specifications Overview The ioPAC 8600 modular RTU controllers are 100% modular, giving users the freedom to choose CPU, power, backplane, communication, and I/O modules. In addition, the ioPAC 8600 enhances the hardware system architecture and key features of the ioPAC 8020 and ioPAC 8500 combined. It not only preserves the dual CPU architecture to support all ioPAC 8600 I/O modules, but also adds an Ethernet bus on the backplane to support Ethernet switch modules. The ioPAC 8600 supports the C/C++ and IEC 61131-3 programming languages and ready-to-run services, including Modbus, data logging, and email alarms to fulfill different customers’ requirements. With Moxa’s Active OPC Server and DA-Center data integration software, the ioPAC 8600 series provides a comprehensive solution for data acquisition and control applications in harsh environments. 2-Wire Ethernet Technology Moxa’s 2-wire Ethernet technology offers system integrators an attractive option for upgrading the train’s IP network to a 10/100 Mbps* Ethernet backbone with existing 2-wire cable. This innovative 2-wire Ethernet technology supports Ethernet bypass functionality, ensuring that the Ethernet backbone will continue to operate even if one ioPAC is without power. As an added plus, with two 2-wire Ethernet modules in one ioPAC, the network can reach 200 Mbps and provide a redundant architecture. *Network performance is related to cable quality when using 2-wire technology. Read-to-Run Service Moxa’s ioPAC 8600 programmable controllers allow programmers to rapidly configure services (SNMP, Modbus RTU/TCP Master/ Slave, E-mail/SMS alarm service, etc.) without writing any programs. The ioPAC can reduce the configuration of massively distributed deployments to a few simple mouse clicks, greatly increasing engineers’ productivity. Automatic Carriage Sequencing (ACS) Moxa’s Automatic Carriage Sequencing technology quickly and automatically resets the train car sequence, without disrupting network transmissions within the train. This technology greatly reduces the operation effort required for trains that frequently rearrange consists. Onboard passenger information systems can also adjust immediately when changes are made. 1 w w w. m o x a . c o m Programmable RTU Controllers Compact Integrated Solution The compact ioPAC 8600 is equipped with universal dual-power inputs that support all railway power voltages, and a new channel-to-channel, high voltage DI/DO module is available for use in trains that use different power systems. The ioPAC 8600 supports a variety of communication interfaces, including Ethernet, serial, CAN*, and MVB*. System integrators can control or monitor sub-systems with the ioPAC 8600, which saves space and has powerful functions to reduce both the system integrators’ budget and installation difficulties. *CAN and MVB available by project request. Specifications Physical Characteristics Housing: Aluminum Dimensions: • 5-slot version: 205.65 x 133.35 x 100 mm (8.1 x 5.25 x 3.94 in) • 9-slot version: 324.8 x 133.35 x 100 mm (12.79 x 5.25 x 3.94 in) Mounting: DIN-rail mounting, wall mounting (optional), and rack mounting (optional) Environmental Limits Operating Temperature: -40 to 75°C (-40 to 176°F) Storage Temperature: -40 to 85°C (-40 to 185°F) Ambient Relative Humidity: 5 to 95% (non-condensing) Altitude: Up to 2000 m Note: Please contact Moxa if you require products guaranteed to function properly at higher altitudes. Standards and Certifications Safety: UL 508 EMI: EN 55022, EN 61000-3-2; EN 61000-3-3; FCC Part 15 Subpart B Class A EMS: EN 55024, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11 Shock: IEC 60068-2-27 Freefall: IEC 60068-2-32 Vibration: IEC 60068-2-6 Rail Traffic: EN 50155*, EN 50121-3-2, EN 50121-4 *Complies with a portion of EN 50155 specifications. Please contact Moxa or a Moxa distributor for details. Note: Please check Moxa’s website for the most up-to-date certification status. Warranty Warranty Period: 5 years Details: See www.moxa.com/warranty Dimensions 133.35 (5.25) Unit: mm (inch) ioPAC 8600 with 5 I/O slots 205.65 (8.1) 241.4 (9.5) 133.35 (5.25) 100 (3.94) ioPAC 8600 with 9 I/O slots 324.8 (12.78) 360.55 (14.19) 100 (3.84) Mounting Kits Wall Mounting Kit (optional) Wall Mounting Kit (optional) DIN-Rail Mounting Kit (Optional) 2 DIN-Rail Mounting Kit (Optional) w w w. m o x a . c o m Programmable RTU Controllers Ordering Information Both ioPAC 8500 modules and ioPAC 8600 modules can be used with the ioPAC 8600 series. For detailed information about each module, see pages 4 to 10. CPU Modules ioPAC 8600-CPU10-M12-C-T: ioPAC 8600 CPU module with M12 Ethernet connectors, C/C++, -40 to 75°C operating temperature ioPAC 8600-CPU10-RJ45-C-T: ioPAC 8600 CPU module with RJ45 Ethernet connectors, C/C++, -40 to 75°C operating temperature ioPAC 8600-CPU10-M12-IEC-T: ioPAC 8600 CPU module with M12 Ethernet connectors, IEC 61131-3, -40 to 75°C operating temperature ioPAC 8600-CPU10-RJ45-IEC-T: ioPAC 8600 CPU module with RJ45 Ethernet connectors, IEC 61131-3, -40 to 75°C operating temperature Power Modules ioPAC 8600-PW10-15W-T: ioPAC 8600 power module with 24 to 110 VDC input, 15 W, -40 to 75°C operating temperature Backplane Modules ioPAC 8600-BM005-T: ioPAC 8600 backplane modules with 5 I/O slots, -40 to 75°C operating temperature ioPAC 8600-BM009-T: ioPAC 8600 backplane modules with 9 I/O slots, -40 to 75°C operating temperature I/O Modules 86M-1832D-T: ioPAC 8600 I/O module with 8 channel to channel isolated DIs, channel LED, 24 VDC sink/source type, -40 to 75°C operating temperature 86M-2830D-T: ioPAC 8600 I/O module with 8 channel to channel isolated DOs, channel LED, 24 VDC sink type, -40 to 75°C operating temperature 86M-2604D-T: ioPAC 8600 I/O module with 6 relays, channel LED, form A (N.O.) type, -40 to 75°C operating temperature 86M-4420-T: ioPAC 8600 I/O module with 4 AOs, 0 to 10 V / -10 to 10 V / 0 to 20 mA / 4 to 20 mA, -40 to 75°C operating temperature 85M-1602-T: ioPAC 8500 I/O module with 16 DIs, 24 VDC sink/source type, -40 to 75°C operating temperature 85M-2600-T: ioPAC 8500 I/O module with 16 DOs, 24 VDC sink type, -40 to 75°C operating temperature 85M-3800-T: ioPAC 8500 I/O module with 8 AIs, 4 to 20 mA, -40 to 75°C operating temperature 85M-3810-T: ioPAC 8500 I/O module with 8 AIs, 0 to 10 V, -40 to 75°C operating temperature 85M-3801-T: ioPAC 8500 I/O module with 8 AIs, 4 to 20 mA, 40 kHz, -40 to 75°C operating temperature 85M-3811-T: ioPAC 8500 I/O module with 8 AIs, 0 to 10 V, 40 kHz, -40 to 75°C operating temperature 85M-6600-T: ioPAC 8500 I/O module with 6 RTDs, -40 to 75°C operating temperature 85M-6810-T: ioPAC 8500 I/O module with 8 TCs, -40 to 75°C operating temperature 85M-5401-T: ioPAC 8500 communication module with 4 serial ports (DB44 connectors), -40 to 75°C operating temperature Optional Accessories (can be purchased separately) DK-DC50131: Din-rail mounting kit WK-75: Wall mounting kit CBL-M12D(MM4P)/RJ45-100 IP67: M12 to RJ45 cable 85M-BKTES: Empty slot cover for ioPAC 8600/8500 modules (3 pcs per package) Package Checklist • ioPAC 8600 CPU module • Serial console cable (C/C++ version only) • Software CD Note: Conformal coating available on request 3 w w w. m o x a . c o m Programmable RTU Controllers ioPAC 8600 Series Modules 32-bit ARM9 192 MHz CPU ioPAC 8600-CPU10-M12-IEC-T CPU Type: 32-bit ARM9 192 MHz CPU OS: Linux Clock: Real-time clock with super capacitor (retains charge for 7 days) ioPAC 8600 CPU10-IEC PWR RDY R/S ERR ioPAC 8600-CPU10 Series: 32-bit ARM9 192 MHz CPU Computer Ethernet Interface SW Memory SDRAM: 64 MB Flash: 32 MB (10 MB reserved for user) FRAM: 128 KB microSD™ Slot: Up to 32 GB (SD 2.0 compatible) RST P1 Note: For units operating in extreme temperatures, industrial grade, wide-temperature microSD cards are required. P2 Switches & Buttons Rotary Switch: 0 to 9 Button: Reset to factory defaults LAN: 2 x 10/100 Mbps, Ethernet bypass or 2 MACs (IPs), jumper selectable, RJ45 or M12 Protection: 1.5 kV magnetic isolation Automation Languages: C/C++, IEC 61131-3 Protocols: Modbus/TCP Master/Slave, Modbus/RTU Master, Active OPC Environmental Limits Operating Temperature: -40 to 75°C Power Requirements Power Consumption: 4.8 W MTBF (mean time between failures) Time: 1,132,561 hrs (TBD) Database: Telcordia (Bellcore) Dual power input, 24 to 110 VDC, 15 W ioPAC 8600-PW10-15W-T: Dual power input, 24 to 110 VDC, 15 W Power ioPAC 8600 Power Input: 24 to 110 VDC PW10-15W PWR Note: Compliant with EN 50155 at 24/48/60/72/110 VDC Wattage: 15 W Galvanic Isolation: 3k VDC Dual Power Input: Yes Environmental Limits Operating Temperature: -40 to 75°C MTBF (mean time between failures) V2+ V2 N.C. V1+ V1 - 4 Time: 1,132,561 hrs (TBD) Database: Telcordia (Bellcore) w w w. m o x a . c o m Programmable RTU Controllers 8 channel to channel isolated DIs, 24 VDC, channel LED, sink/source type 86M-1832D-T: 8 channel to channel isolated DIs, 24 VDC, channel LED, sink/source type Counter Frequency: 5 kHz Inputs and Outputs Digital Inputs: 8 channels Isolation: To system: 3k VDC or 2k Vrms Channel to channel: 1k VDC Digital Filtering Time Interval: Software selectable (by 0.1 ms) Digital Inputs Environmental Limits Sensor Type: Wet contact (NPN or PNP) I/O Mode: DI, counter, or frequency mode Wet Contact: NPN: • On: 0 to 3 VDC • Off: 10 to 30 VDC PNP: • Off: 0 to 3 VDC • On: 10 to 30 VDC Physical Characteristics Wiring: I/O cable, max. 16 AWG Connector: Spring type terminal block Operating Temperature: -40 to 75°C Power Requirements Power Consumption: 0.3 W MTBF (mean time between failures) Time: 1,132,561 hrs (TBD) Database: Telcordia (Bellcore) 8 channel to channel isolated DOs, 24 VDC, channel LED, sink type 86M-2830D-T: 8 channel to channel isolated DOs, 24 VDC, channel LED, sink type Inputs and Outputs Physical Characteristics Digital Outputs: 8 channels Isolation: To system: 3k VDC or 2k Vrms Channel to channel: 1k VDC Wiring: I/O cable, max. 16 AWG Connector: Spring type terminal block Digital Outputs Power Requirements Environmental Limits Operating Temperature: -40 to 75°C Type: Sink Power Consumption: 1.8 W (with all DOs on) I/O Mode: DO or PWM mode MTBF (mean time between failures) Pulse Output Frequency: 1 kHz Time: 792,571 hrs (TBD) Short Circuit Protection: 750 mA @ 25°C Database: Telcordia (Bellcore) Over-voltage Protection: 41 VDC Over-current Protection: 2.6 A (4 channels @ 650 mA) Over-temperature Shutdown: 175°C (typical), 150°C (min.) Current Rating: 200 mA per channel 6 relays, channel LED, form A (N.O.) type 86M-2604D-T: 6 relays, channel LED, form A (N.O.) type Electrical Endurance: 60,000 operations @ 5 A resistive load Inputs and Outputs Relay Outputs: 6 channels Isolation: To System: 3k VDC or 2k Vrms Relay Outputs Type: Form A (N.O.) I/O mode: DO or PWM mode Pulse Output Frequency: 0.33 Hz Contact Current Rating: Resistive Load: 5 A @ 30 VDC, 250 VAC Relay On/Off Time: 10 ms (max.) Initial Insulation Resistance: 1000 M ohms (min.) @ 500 VDC Mechanical Endurance: 5,000,000 operations 5 Contact Resistance: 100 m ohms (max.) Physical Characteristics Wiring: I/O cable, max. 16 AWG Connector: Spring type terminal block Environmental Limits Operating Temperature: -40 to 75°C Power Requirements Power Consumption: 3 W (with all relays on) MTBF (mean time between failures) Time: 1,512,906 hrs (TBD) Database: Telcordia (Bellcore) w w w. m o x a . c o m Programmable RTU Controllers 4 analog outputs, 0 to 10 V or -10 to 10 V or 0 to 20 mA or 4 to 20 mA 86M-4420-T: 4 analog outputs, 0 to 10 V or -10 to 10 V or 0 to 20 mA or 4 to 20 mA Update Rate: Software polling or waveform mode Inputs and Outputs Analog Outputs: 4 channels Isolation: To system: 3k VDC or 2k Vrms Analog Outputs Resolution: 12 bits Output range: 0-10 V, -10-10 V, 0-20 mA, 4-20 mA I/O mode: Static or Waveform mode Voltage Output: 10 mA (max.) Accuracy: ±0.1% FSR @ 25°C ±0.3% FSR @ -40 and 75°C Current Load Resistance: Internal Power: 400 ohms External 24 VDC Power: 1000 ohms 6 Wavemode Frequency: 125 Hz Physical Characteristics Wiring: I/O cable, max. 16 AWG Connector: Spring type terminal block Environmental Limits Operating Temperature: -40 to 75°C Power Requirements Power Consumption: 2.26 W (Voltage) 3.45 W (Current) MTBF (mean time between failures) Time: 1,530,690 hrs (TBD) Database: Telcordia (Bellcore) w w w. m o x a . c o m Programmable RTU Controllers ioPAC 8500 Series Modules 16 digital inputs, 24 VDC, sink/source, dry contact type 85M-1602-T: 16 digital inputs, 24 VDC, sink/source, dry contact type Common Type: 8 points per COM Inputs and Outputs Digital Inputs: 16 channels Isolation: 3k VDC or 2k Vrms Digital Inputs Sensor Type: Wet contact (NPN or PNP), dry contact I/O Mode: DI or event counter Dry Contact: • On: short to GND • Off: open Wet Contact (DI to GND): NPN (DI to GND): • On: 0 to 3 VDC • Off: 10 to 30 VDC PNP (DI to GND): • Off: 0 to 3 VDC • On: 10 to 30 VDC Counter Frequency: 5 kHz Digital Filtering Time Interval: Software selectable (by 0.1 ms) Physical Characteristics Wiring: I/O cable, max. 16 AWG Connector: Spring type terminal block Environmental Limits Operating Temperature: -40 to 75°C Power Requirements Power Consumption: 1.2 W @ 3.3 VDC MTBF (mean time between failures) Time: 1,132,561 hrs Database: Telcordia (Bellcore) 16 digital outputs, 24 VDC, sink type 85M-2600-T: 16 digital outputs, 24 VDC, sink type Inputs and Outputs Physical Characteristics Digital Outputs: 16 channels Isolation: 3k VDC or 2k Vrms Wiring: I/O cable, max. 16 AWG Connector: Spring type terminal block Digital Outputs Environmental Limits Type: Sink I/O Mode: DO or pulse output Pulse Output Frequency: 5 kHz Over-voltage Protection: 45 VDC Over-current Protection: 2.6 A (4 channels @ 650 mA) Over-temperature Shutdown: 175°C (typical), 150°C (min.) Current Rating: 200 mA per channel Operating Temperature: -40 to 75°C Power Requirements Power Consumption: 0.85 W @ 3.3 VDC MTBF (mean time between failures) Time: 792,571 hrs Database: Telcordia (Bellcore) 8 analog inputs, 4 to 20 mA 85M-3800-T: 8 analog inputs, 4 to 20 mA Inputs and Outputs Physical Characteristics Analog Inputs Environmental Limits Analog Inputs: 8 channels Isolation: 3k VDC or 2k Vrms Type: Differential Resolution: 16 bits I/O Mode: 4 to 20 mA (wire off) Accuracy: ±0.1% FSR @ 25°C ±0.3% FSR @ -40 and 75°C Sampling Rate: • All channels: 100 samples/sec • Per channel: 12.5 samples/sec Input Impedance: 125 ohms (min.) 7 Wiring: I/O cable, max. 16 AWG Connector: Spring type terminal block Operating Temperature: -40 to 75°C Power Requirements Power Consumption: 1.05 W @ 3.3 VDC MTBF (mean time between failures) Time: 1,512,906 hrs Database: Telcordia (Bellcore) w w w. m o x a . c o m Programmable RTU Controllers 8 analog inputs, 0 to 10 VDC 85M-3810-T: 8 analog inputs, 0 to 10 VDC Inputs and Outputs Analog Inputs: 8 channels Isolation: 3k VDC or 2k Vrms Analog Inputs Type: Differential Resolution: 16 bits I/O Mode: 0 to 10 VDC Accuracy: ±0.1% FSR @ 25°C ±0.3% FSR @ -40 and 75°C Sampling Rate: • All channels: 100 samples/sec • Per channel: 12.5 samples/sec Input Impedance: 200 k-ohms (min.) Physical Characteristics Wiring: I/O cable, max. 16 AWG Connector: Spring type terminal block Environmental Limits Operating Temperature: -40 to 75°C Power Requirements Power Consumption: 1.04 W @ 3.3 VDC MTBF (mean time between failures) Time: 1,530,690 hrs Database: Telcordia (Bellcore) 8 analog inputs, 4 to 20 mA, 40 kHz 85M-3801-T: 8 analog inputs, 4 to 20 mA, 40 kHz Inputs and Outputs Input Impedance: 125 ohms (min.) Analog Inputs: 8 channels Isolation: 3k VDC or 2k Vrms Analog Inputs Type: Differential Resolution: 16 bits I/O Mode: 4 to 20 mA (wire off) Historical Data Buffering: 60KB per channel, 6 seconds data buffer at 5KHz Accuracy: ±0.1% FSR @ 25°C ±0.3% FSR @ -40 and 75°C Sampling Rate: • All channels: 40k samples/sec • Per channel: 5k samples/sec Physical Characteristics Wiring: I/O cable, max. 16 AWG Connector: Spring type terminal block Environmental Limits Operating Temperature: -40 to 75°C Power Requirements Power Consumption: 1.25 W @ 3.3 VDC MTBF (mean time between failures) Time: 1,410,655 hrs Database: Telcordia (Bellcore) 8 analog inputs, 0 to 10 VDC, 40 kHz 85M-3811-T: 8 analog inputs, 0 to 10 VDC, 40 kHz Inputs and Outputs Physical Characteristics Analog Inputs: 8 channels Isolation: 3k VDC or 2k Vrms Analog Inputs Type: Differential Resolution: 16 bits I/O Mode: 0 to 10 VDC Historical Data Buffering: 60 KB per channel, 6 seconds data buffer at 5 kHz Accuracy: ±0.1% FSR @ 25°C ±0.3% FSR @ -40 and 75°C Sampling Rate: • All channels: 40k samples/sec • Per channel: 5k samples/sec Input Impedance: 20 M-ohms (min.) 8 Wiring: I/O cable, max. 16 AWG Connector: Spring type terminal block Environmental Limits Operating Temperature: -40 to 75°C Power Requirements Power Consumption: 1.25 W @ 3.3 VDC MTBF (mean time between failures) Time: 1,426,112 hrs Database: Telcordia (Bellcore) w w w. m o x a . c o m Programmable RTU Controllers 6 RTD inputs 85M-6600-T: 6 RTD inputs Inputs and Outputs RTD Inputs: 6 channels Isolation: 3K VDC or 2K Vrms RTD Inputs Input Type: • PT50, PT100, PT200, PT500 (-200 to 850°C) • PT1000 (-200 to 350°C) • JPT100, JPT200, JPT500 (-200 to 640°C) • JPT1000 (-200 to 350°C) • NI100, NI200, NI500 (-60 to 250°C) • NI1000 (-60 to 150°C) • NI120 (-80 to 260°C) • Resistance of 310, 620, 1250, and 2200 Sampling Rate (single channel): • All channels: 12 samples/sec • Per channel: 2 samples/sec Resolution: 0.1°C or 0.1 ohm Accuracy:±0.1% FSR @ 25°C ±0.3% FSR @ -40 and 75°C Input Impedance: 625 kohms (min.) Physical Characteristics Wiring: I/O cable, max. 16 AWG Connector: Spring type terminal block Environmental Limits Operating Temperature: -40 to 75°C 8 thermocouple inputs 85M-6810-T: 8 thermocouple inputs Inputs and Outputs Analog Inputs: 8 channels Isolation: 3K VDC or 2K Vrms Thermocouple Inputs Sensor Type: J (0 to 750°C), K (-200 to 1250°C), T (-200 to 350°C), E (-200 to 900°C), R (-50 to 1600°C), S (-50 to 1760°C), B (600 to 1700°C), N (-200 to 1300°C) Millivolt Type: • Mode: ±78.126 mV, ±39.062 mV, ±19.532 mV • Fault and over-voltage protection: -35 to +35 VDC (power off); -25 to +30 VDC (power on) Sampling Rate (single channel): • All channels: 12 samples/sec • Per channel: 1.5 samples/sec Resolution: 16 bits 9 Accuracy:±0.1% FSR @ 25°C ±0.3% FSR @ -40 and 75°C Input Impedance: 1 Mohms (min.) Physical Characteristics Wiring: I/O cable, max. 16 AWG Connector: Spring type terminal block Environmental Limits Operating Temperature: -40 to 75°C w w w. m o x a . c o m Programmable RTU Controllers 4 serial ports 85M-5401-T: 4 serial ports Serial Communication Interface: 4 RS-232/422/485 ports, software selectable (DB44 male) Isolation: 3K VDC or 2K Vrms Note: DB44 to 4-port DB9 cable included in the package. Serial Communication Parameters Parity: None, Even, Odd Data Bits: 7, 8 Stop Bits: 1, 2 Flow Control: RTS/CTS, XON/XOFF Baudrate: 300 bps to 921.6 kbps Physical Characteristics Connector: DB44 male Environmental Limits Operating Temperature: -40 to 75°C Power Requirements Power Consumption: 1.24 W @ 3.3 VDC MTBF (mean time between failures) Time: 596,611 hrs Database: Telcordia (Bellcore) Serial Signals RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND RS-422: Tx+, Tx-, Rx+, Rx-, GND RS-485-4w: Tx+, Tx-, Rx+, Rx-, GND RS-485-2w: Data+, Data-, GND 10 © Moxa Inc. All rights reserved. Updated Jul. 27, 2015. Specifications subject to change without notice. Please visit our website for the most up-to-date product information.