UNISync 5G-A - FEI
Transcription
UNISync 5G-A - FEI
UNISync 5G-A Reliability Durability Survivability UNISync 5G-A (FE-5200A) Adaptability TIMING NEXT Cost GENERATION NETWORKS... Efficiency U NI S y nc 5 G- A - H I-C apacity, Mi c r o - P r o c e s s o r Co n t r o l l e d , Ca r r i e r C la s s SSU UNISync 5G-A (FE-5200A) FEATURES • 160 Main Shelf Outputs • Total System Capacity — 1440 Outputs • DS-1/CC Combo Output Modules • Port Level Output Programmability • 10 Input Capacity • Provision Input Signal Formats in Software • Input Performance Monitoring • Independent Clock BYPASS Module • NTP Server Module w/ Optical and Gig Ethernet Total Software Management The UNISync 5G-A Value Proposition For the first time NO hardware assemblies, The UNISync 5G-A beats the • PTP/IEEE-1588 Grand Master Module w/ Optical and Gig Ethernet jumpers, or switches are used to configure competition with: common telecom signal formats in the UNISync • • Fast, Easy System Installation and Provisioning All software management interfaces are 5G-A – inbound or outbound. UNISync 5G-A – 160 Competition – 140 Remote Management • full utilization of Centralized Network Operations (CNOC) for alarm monitoring eliminates stranded ports • Superior source diversity with matching 40 port capacity on and management. 4 card groups Microprocessor Control & Memory Features • Superior efficiency in managing office The UNISync 5G-A operates with Intel™ cuts with output groups of 10 microprocessors on the COM and both IOP corresponding to the DCD TOCA and modules. The COM module is the primary home for all system databases, but database's are backed up to both IOP modules. Microprocessors on the output modules enable provisioning and alarm management to the port level. 2 Superior port utilization: port programmability reduces or remotely accessible via TCP/IP LAN allowing Center Superior main shelf port capacity: www.fei-zyfer.com TOTA modules • Superior input flexibility – all inputs may be software provisioned for a variety of signal formats Customer Solutions, Easily Configured UNISync 5G-A Rubidium IOP Module System Software Control Features The UNISync 5G-A operates with a standard TL-1 software management interface. All modules auto-provision during installation and initialization. In the event a module is replaced by a maintenance spare, the system automatically performs both hardware and software compatibility checks, downloads any needed software, and provisions the modules identically to the module it replaced. Record keeping is simplified by entering output port assignments and input reference sources in assignable data fields. Software storage of CLEI codes and Mfg Serial numbers aid field servicing and PCN administration. Oscillator Options UNISync 5G-A IOP modules are operated with either the Standard Quartz ST-3E or the Rubidium ST-2 oscillators. The system supports both mixed stratum operation (ST3E/ ST2) as well as matched stratum levels. Sub-Tending/Remote Clock Operation Any main shelf system can be used as a BY-PASS 10 1 INPUT 1 PROGRAMMABLE 2 INPUT 2 INPUTS 3 INPUT 3 4 INPUT 4 5 INPUT 5 DS1/SF DS1/ESF E1 2MHz E1 2Mbit/s 1/5/10MHz CC ( INPUT 1 AND 2 ) 6 INPUT 6 7 INPUT 7 8 INPUT 8 9 INPUT 9 10 INPUT 10 INPUT 1 IOP 1 OUTPUT CARD 2 CLOCK CARD 1 -48VB POWER SUPPLY A INPUT 3 POWER SUPPLY B INPUT 5 INPUT 7 INPUT 8 INPUT 9 INPUT CONNECTION PANEL INPUT 10 OUTPUT CONNECTION PANEL 1 40 OUTPUTS master or sub-tending clock merely by changing in software the provisioning of input 1 and 2. SSM's can be transmitted to OUTPUT CONNECTION PANEL 2 40 OUTPUTS downstream NE's through the sub-tending clock if needed. The sub-tending clock has its own IP address for both remote management and alarm surveillance and IOP 2 OUTPUT CARD 5 OUTPUT CARD 6 retains the protection of BYPASS. OUTPUT CONNECTION PANEL 3 40 OUTPUTS Alarm Reporting Modes The UNISync 5G-A reports system and INPUT 4 INPUT 6 OUTPUT CARD 3 OUTPUT CARD 4 INPUT 2 -48VA OUTPUT CARD 1 CLOCK CARD 2 OUTPUT CARD 7 OUTPUT CARD 8 OUTPUT CONNECTION PANEL 4 MANAGEMENT CARD CRAFT ALARM ALARM IN OUT 40 OUTPUTS module alarms via visual LED indicators, TL-1 Autonomous Output (AO) messaging, LAN and through contact closure terminals. Everything is alarmed including expansion shelf umbilical cables and the BYPASS module. 3 UNISync 5G-A PRODUCT SPECIFICATIONS UNISync 5G-A SHELF MODULES INPUT/OUTPUT CAPACITY Power Supply Modules UNISync 5G-A Inputs • • • • Dual load sharing Each receives power from a dedicated back panel power input Automatic redundancy in case of module failure Front panel fuses and power status LED's Communications Module • • • • • UNISync 5G-A System CPU System Communications Controller BOTH external and internal Com processes Provides system TL-1 Agent Manages all system security processes Manages all database storage, access, and synchronization with IOP back up Input/Output/Processor Module • • • Dual Clock Modules Input Capacity - Up to 10 inputs Dual System database Back Up to the Com module Output Module • • • • Paired in adjacent slots for 1 to 1 output protection Outputs are software assignable for DS-1/CC Inventory Port Assignments in Software Alarm visibility to the port level • • • • • • • • Slot compatible - Main/Exp Back Panel I/O Fixture Adapts to Existing DB-25 Sockets Gigabit Ethernet Interface NTP v 4.2.4 PTP IEEE-1588 Module • • • • Slot compatible - Main/Exp Back Panel I/O Fixture Adapts to Existing DB-25 Sockets Gigabit Ethernet Optical SFP - Front Electrical Outputs - Rear www.fei-zyfer.com Sales: Main: 714-933-4002 Fax: 714-933-4001 E-mail: sales@fei-zyfer.com UNISync 5G-A Outputs • • • • 40 outputs per module, paired for 1 to 1 protection Main shelf capacity - 160 outputs Expansion capacity - 4 expansion shelves, 320 outputs per shelf Total system capacity - 1440 outputs PERFORMANCE MONITORING • • • Simultaneous Data Collection on all Inputs Data Metrics - Frequency Offset, TIE, MRTIE, TDEV, LMRTIE Average Periods-from 10 to 100,000 seconds Technical Support: 24/7: 877-700-US5G 877-700-8754 (USA only) Main: 714-933-4002 Fax: 714-933-4001 E-mail: techsupport@fei-zyfer.com COMMUNICATION AND MANAGEMENT Craft/Local Ports • 1 on front (Com Module), 2 on Rear Panel Remote Management • • NTP Client/Server Module • • Termination - Wire wrap on back panel Bridged - Each input to both IOP modules Inputs are software assignable CC, DS-1 (SF/ESF), E-1, 1, 5, or 10 MHz User Selectable Priority Options - Priority 1 to 10 Up to 10 Inputs each IOP module Selectable SSM activation - Gen 1 or Gen 2 7321 Lincoln Way Garden Grove, CA 92841 1 RJ-45 Ethernet 3-pin terminations for output alarms - 3 Major, 3 Minor (NC/NO) Software Interface • • Standards compliant TL-1 agent GUI interface Standards Compliance • • NEBS Level III - testing and evaluation by Telcordia Labs All Telecordia GR standards covering TSG’S, oscillators and network equipment - validated by Telcordia Labs 417-8100C