Helicoid Sleeve Brochure - Giles Engineering Consultancy Limited
Transcription
Helicoid Sleeve Brochure - Giles Engineering Consultancy Limited
Full Composite Epoxy Sleeve Designed For The Strengthening And Protection Of Pipelines • Technologically advanced • Online Installation • Cost effective • Verified as per ASME PCC-2 Combining the Best of both Epoxy Sleeve Repairs and Composite Wrapping Techniques The Helicoid Epoxy Sleeve ™ is a helically wound, carbon fibre reinforced, mechanically interlocking PE or PTFE strip, allowing an annulus of approximately 25 to 40 mm around the pipe to be filled with an epoxy or cementatious grout, therewith giving outstanding strengthening and protection qualities Benefits Of Helicoid Epoxy Sleeve TM Pre-engineered Off-the-shelf Diameters between 150mm to 600mm The Helicoid Epoxy Sleeve™ has been designed, tested and certified in accordance with the ASME PCC-2 and is an approved repair system under the ASME 31.4 and ASME 31.8 Length up to 10.0m The sleeve can be installed to risers, up to 3.0 m below MSL, completely diverless, in diameters between 150 mm to 600 mm and up to a length of 10.0 m in one single application, without the shut down of the facilities Above water and subsea installation For strengthening and protection On-line installation Diverless riser installation Corrosion resistant Impact resistant Temperatures up to 120 degrees Celsius Easy and fast installation Durable Marine growth resistant SECTIONAL CUT OUT DETAIL Cost effective Multiple sleeves to accommodate extended length Polyamide End Cap Independent third party verification by Lloyd’s Register and tested in accodance with ASME PCC-2 “Repair of Pressure Equipment and Piping” Interlocking PE or PTFE Sleeve Grout Fill Carbon Fibre Reinforcement FULL COMPOSITE EPOXY SLEEVE DESIGNED FOR THE STRENGTHENING AND PROTECTION OF RISERS AND SUB SEA PIPELINES HELICOID Epoxy Sleeve TM Technology that is simply the best Typical Installation Sequence on Riser ( Riser Splash Zone Area ) Main Characteristics 1. Installation of winding cage 2. Insertion of Polyethylene strip to commence winding of sleeve 3. Attachment of polyamide caps, 4. Sleeve is wound to full required length 5. Injection of epoxy grout 6. Helicoid sleeve repair complete Reinforcement properties Fibre nature : Carbon fiber, Torayca T700 SC Fibre direction: uni-directional, pultruded Density: 1,750 kg/m3 Tensile Strength (ASTM D 3039): 1,880 N/mm2 Young’s Modulus (ASTM D 3039): 141,000 N/mm2 Poisson’s Ratio (ASTM D 3039): 0.34 Flexural Strength (ASTM D 790): 1,480 N/mm2 Flexural Modulus (ASTM D 790): 80,000 Shear Modulus (ASTM D 5379): 75.46 N/mm2 Coefficient of Thermal Expansion (ASTM E 831): -5.0 x 10-5 mm/mm/oC Glass Transition Temperature (ASTM D 3418): 121oC Grout Properties Chemical family : Epoxy Compressive Strength (ASTM C 579): 99.3 N/mm2 Flexural Strength (ASTM C 580): 33.9 N/mm2 Modulus of Elasticity (ASTM C 580): 8,951 N/mm2 Bond Strength to Steel (UW) (ASTM D 4541) > 10.8 N/mm2 Lap Shear Strength to Steel (ASTM D 3165): 7.1 N/mm2 Heat Deflection Temperature (ASTM D 648): 116oC Typical Installation Sequence on Sub Sea Pipeline Water Absorption (ASTM C 413-01): 0.18 % Linear Coefficient of Thermal Expansion (ASTM C 531): 2.3 x 10-3/oC PE Strip Properties Tensile Strength ( ASTM D 638) : 28 N/mm2 Flexural Modulus (ASTM D 790): 1,400 N/mm2 Izod Impact (ASTM D 256): 0.07 Joules/mm of Notch Heat Deflection Temperature (ASTM D 648) : (@ 0.5N/mm2) : 78 degrees C 1. Installation of winding cage 2. Winding of sleeve continued to full required length 3. Epoxy grout injection procedure 4. Cut out shows epoxy grout injection into sleeve annulus 5. Helicoid sleeve repair complete 6. Sleeve repair procedure repeated along pipeline as required Water Vapour Transmission Rate (ASTM E96): 0.0004 g/h/m2 Linear Coefficient of Thermal Expansion (ASTM D 696): 3.85 x 10-5 /oC Surface Preparation Of Riser As part of the installation of the sleeve, a system has been developed for the removal of marine growth, neoprene liners and coatings of up to 3.00 m below MSL, without the intervention of divers The lightweight, modular equipment can be installed by a crew of 2 technicians and is capable of achieving surface cleanliness of up to Swedish Standard SA 2.5 by means of high pressure water - and abrasive blasting The level of cleanliness can be monitored from the top deck through attached CCTV cameras Preliminary Riser Surface Preparation 1. Installation of riser cleaning equipment 3. Cleaning of riser below water to required depth 2. Surface preparation of riser 3. Cleaning of riser above water to required depth 5. Cleaning under water 6. Completion of surface preparation YOUR ASSURANCE IN STRENGTH AND PROTECTION Lloyd's Register’s test certificates can be made available upon request Simply The Best Pipeline Strengthening & Protection System Merit Technologies Sdn Bhd (comp. no.655607-U) No.8, Jalan PJU 3/45, Sunway Damansara Technology Park, 47810, Petaling Jaya, Selangor Darul Ehsan, Malaysia Tel: + 60 3 7805 3811 Fax: + 60 3 7805 4811 email: info@merit.net.my www.helicoid.com.my