Fluorescent Emergency Ballast Product Guide

Transcription

Fluorescent Emergency Ballast Product Guide
EMERGENCY SOLUTIONS for
FLUORESCENT and LED RETROFIT LAMPS
IOTA’s Fluorescent Emergency Ballasts set the standard for emergency lighting solutions.
Our innovative product designs such as the ISL Series slim profile battery packs and AC
output emergency ballasts have paved the way for bringing safe, reliable emergency lighting
to today’s egress applications. We continually expand and enhance our product lines so our
customers have access to reliable emergency lighting solutions that keep pace with the latest ballast and lamp technologies. When the lights go out, you’re prepared...
SOLUTIONS FOR DESIGNERS...
IOTA Emergency Ballasts offer UL Listed integral emergency lighting
solutions for your lighting schedule. Our products deliver a wide range of
lumen output levels to match your egress environment without the need
for additional circuits or unattractive wall-mounted fixtures.
SOLUTIONS FOR MANUFACTURERS...
Whether it’s a strip fixture, downlight fixture or troffer with limited
compartment space, IOTA’s RoHS-compliant products deliver the
value of reliable emergency options to your fixture designs and
lamp and ballast requirements.
SOLUTIONS FOR RETROFIT...
Adding emergency lighting to an existing application or revitalizing your environment with new LED tube lamps? IOTA offers solutions that allow you
to achieve your retrofit objectives without compromising your path of egress
requirements. Our knowledgeable and friendly Customer Service team are
happy to assist with selecting the best emergency battery pack for your project. Call us at 1-800-866-4682 or visit us on-line at www.iotaengineering.com
to take advantage of IOTA’s emergency lighting expertise...we can guide you
to the IOTA solution that’s right for you!
IOTA ENGINEERING
TEL: 1-800-866-4682
FAX: (520)
741-2837
www.iotaengineering.com
LINEAR FLUORESCENT
IOTA’s linear fluorescent products provide practical solutions for most linear lamp type fixtures
utilizing 2 to 8 ft T5 through T12 lamps.
I-32
500 LUMENS
I-40
700 LUMENS
I-48
I-320
700 LUMENS
1200 LUMENS
LAMPS OPERATED
Most 2′-4′ single, bipin 28W T5
through T12 fluorescent lamps
LAMPS OPERATED
Most 2′-4′ single, bipin T8 through
T12 fluorescent lamps
LAMPS OPERATED
Most 2′-8′ single, bipin T8 through
T12 HO and VHO fluorescent lamps
LAMPS OPERATED
Most 2′-4′ single, bipin T8,
2′-4′ T5, HO and VHO
fluorescent lamps
INITIAL ILLUMINATION
1 lamp 500 lumens
90 Minutes
INITIAL ILLUMINATION
1 lamp 700 lumens
90 Minutes
INITIAL ILLUMINATION
1 (2′-8′) lamp 700 lumens
2 (2′-4′) lamps 350 lumens each
90 Minutes
INITIAL ILLUMINATION
1 (2′-4′) lamp 1200 lumens
90 Minutes
CASE DIMENSIONS
9.5″ x 2.0″ x 1.0″ (Fig. A)
CASE DIMENSIONS
9.5″ x 2.375″ x 1.5″ (Fig. B)
CASE DIMENSIONS
9.5″ x 2.375″ x 1.5″ (Fig. B)
CASE DIMENSIONS
13.0″ x 2.2″ x 1.25″ (Fig. C)
WEIGHT
1.5 lbs
WEIGHT
2.4 lbs
WEIGHT
2.4 lbs
WEIGHT
2.5 lbs
FIG. A
ALL IOTA EMERGENCY BALLASTS INCLUDE
THE FOLLOWING FEATURES...
TIME DELAY
ENHANCEMENT
FIG. B
‘End of Lamp Life’ circuitry in AC ballasts can activate when power switches
from the emergency battery pack to the AC supply. IOTA emergency battery
packs provide a brief delay that allows time for the AC ballast to recognize
that the lamp is still functioning and eliminate conflicts with testing and operation of the emergency battery pack.
OPEN CIRCUIT
ISOLATION
FIG. C
All IOTA emergency ballasts guard against the dangers of an open circuit
caused by an absence of load - such as when the lamps are burned out or
are being removed for replacement.
LED RETROFIT SOLUTIONS
MOUNTING CENTER 12.6
4
IOTA ENGINEERING
AC output IOTA emergency ballasts are compatible and UL Listed for select
LED retrofit tube models. Visit www.iotaengineering.com/ledretrofit.htm for
current compatibility listings.
LINEAR FLUORESCENT
Increased emergency illumination and
additional safety features are beneficial
assets to projects such as municipal facilities, retirement communities, schools
and daycares. These units deliver IOTA’s
unique advantages to a wide range of
critical applications.
I-232
1400 LUMENS
I-880
2000 LUMENS
LAMPS OPERATED
(2) 2′-4′ single, bipin T8 through
T12 HO and VHO fluorescent lamps
in parallel
LAMPS OPERATED
Most 2′-8′ single, bipin T8 through
T12, 2′-4′ T5, HO and VHO
fluorescent lamps
INITIAL ILLUMINATION
1400 lumens
2 lamps 700 lumens each
90 Minutes
I-160
3000 LUMENS
I-162
3000 LUMENS
LAMPS OPERATED
Most 2′-4′ single, bipin T8 through
T12, 2′-4′ T5, HO and VHO
fluorescent lamps, and 18W-70W
4-pin compact fluorescent lamps.
LAMPS OPERATED
(2) 2′-4′ single, bipin T8
through T12 and 54W T5, HO
and VHO fluorescent lamps
in parallel
INITIAL ILLUMINATION
1 (2′-8′) lamp 2000 lumens
2 (2′-4′) lamps 1000 lumens each
90 Minutes
INITIAL ILLUMINATION
1 (2′-4′) lamp 3000 lumens
1 4-pin compact lamp 1750 lumens
INITIAL ILLUMINATION
3000 lumens
2 lamps 1500 lumens each
90 Minutes
CASE DIMENSIONS
13.3″ x 2.375″ x 1.5″ (Fig. D)
CASE DIMENSIONS
18.6″ x 2.375″ x 1.5″ (Fig. E)
CASE DIMENSIONS
16.375″ x 3.0″ x 3.0″ (Fig. F)
WEIGHT
3.6 lbs
WEIGHT
4.4 lbs
WEIGHT
9.75 lbs
CASE DIMENSIONS
16.375″ x 3.0″ x 3.0″ (Fig. F)
WEIGHT
9.75 lbs
FIG. D
PARALLEL OPERATION
FIG. E
The Parallel Operation design of the I-232 and
I-162 offers an additional level of safety by operating two lamps in parallel in the emergency mode.
If one of the lamps is inoperable, the emergency
ballast will continue to operate the remaining lamp.
I-880 INTEGRAL PROFILE
FIG. F
The I-880 is the only emergency battery pack that
combines 2000 lumen emergency illumination
with an integral housing for installation within troffer and strip fixtures.
RECESSED MOUNTING PAN
The I-160 and I-162 are also available with a recessed mounting pan option, allowing for installation directly into grid ceiling applications with easy
access to the test switch and charge indicator
accessories.
www.iotaengineering.com
5
T5 - SLIM PROFILE FLUORESCENT
The ISL Series, the original slim-design battery
pack, implements a narrow profile ideal for T5
fixtures. With output options up to 1300 lumens,
the ISL Series emergency ballasts meet the
demands for both safety and design.
ISL-28
500 LUMENS
LAMPS OPERATED
Most 2′-4′ T5 up to 28W or T8 linear
fluorescent lamps.
INITIAL ILLUMINATION
1 lamp 500 lumens
90 Minutes
CASE DIMENSIONS
14.2″ x 1.18″ x 1.15″ (Fig. G)
WEIGHT
2.0 lbs
FIG. G
ISL-54
ISL-540
825 LUMENS
1300 LUMENS
LAMPS OPERATED
Most 2′-4′ 28W and 54W T5, or T8 linear
lamps, including HO, and 40-55 watt 4-pin
long compact fluorescent lamps.
LAMPS OPERATED
Most 2′-4′ 28W and 54W T5, or T8 linear lamps,
including HO, and 40-55 watt 4-pin long compact
fluorescent lamps. 35W T5 Modification available
INITIAL ILLUMINATION
1 lamp 825 lumens
90 Minutes
INITIAL ILLUMINATION
1 lamp 1300 lumens
90 Minutes
CASE DIMENSIONS
17.5″ x 1.18″ x 1.15″ (Fig. H)
CASE DIMENSIONS
21.5″ x 1.18″ x 1.15″ (Fig. I)
WEIGHT
2.4 lbs
WEIGHT
3.0 lbs
THE ORIGINAL SLIM-LINE
EMERGENCY BALLAST...
FIG. H
FIG. I
IOTA introduced the ISL Series to provide
emergency solutions for T5 applications
and architectural fixture designs with limited
compartment space. The ISL Series combines form and function with up to 1300 lumen emergency illumination, AC output for
low mercury content amalgam lamps, and is
rated for use in damp locations and enclosed
and gasketed fixtures.
LED RETROFIT
SOLUTIONS
AC output IOTA emergency ballasts are compatible
and UL Listed for select LED retrofit tube models. Visit
www.iotaengineering.com/ledretrofit.htm for current
compatibility listings.
6
IOTA ENGINEERING
4-PIN COMPACT FLUORESCENT
With AC output and different mounting options,
IOTA compact fluorescent emergency ballasts
provide versatile solutions for many compact
lamp types and fixtures in use today.
I-42
650 LUMENS
I-420
1100 LUMENS
LAMPS OPERATED
10W-42W 4-pin rapid start compact lamps,
including twin, triple, quad tube, and 2D
fluorescent lamps
LAMPS OPERATED
10W-57W 4-pin rapid start com-pact
lamps, including twin, triple, quad tube,
and 2D fluorescent lamps
INITIAL ILLUMINATION
1 (10W-42W) lamp 650 lumens
2 (10W-18W) lamps 325 lumens ea.
90 Minutes
INITIAL ILLUMINATION
1 (10W-57W) lamp 1100 lumens
2 (10W-26W) lamps 550 lumens ea.
90 Minutes
CASE DIMENSIONS
9.5″ x 2.375″ x 1.5″ (Fig. B)
CASE DIMENSIONS
13.3″ x 2.375″ x 1.5″ (Fig. D)
WEIGHT
EM-A 4.4 lbs
EM-B 2.4 lbs
WEIGHT
EM-A 5.4 lbs
EM-B 3.5 lbs
I-462
1850 LUMENS
LAMPS OPERATED
(2) 13W-42W 4-pin rapid start compact lamps, including twin, triple, quad
tube, and 2D fluorescent lamps, and
18W-50W long compacts.
INITIAL ILLUMINATION
1850 lumens
2 lamps 925 lumens each
90 Minutes
CASE DIMENSIONS
16.375″ x 3.0″ x 3.0″ (Fig. F)
WEIGHT
9.75 lbs
FIG B.
FIG D.
AC OUTPUT FOR LOW MERCURY
CONTENT AMALGAM LAMPS
Series AC emergency ballasts from IOTA were the first emergency battery
packs to offer compatibility with today’s low-mercury content amalgam
lamps. The advent of this lamp technology required a unique emergency
ballast that could operate with the sensitive design of the lamp. IOTA’s AC
Series emergency ballasts were designed specifically to deliver compatibility with these newer environmentally-friendly lamps.
FIG F.
MOUNTING
OPTIONS
IOTA battery packs for compact lamps offer a variety of mounting configurations to meet several installation requirements. Refer to page 8 for
an overview of available mounting options.
www.iotaengineering.com
7
MOUNTING CONFIGURATIONS
IOTA Emergency Ballasts for compact lamps are available in a variety
of mounting configurations to accommodate various fixture types and
mounting scenarios. Refer to individual product specifications to determine which mounting configuration is available for each emergency ballast model.
2-PIN COMPACT FLUORESCENT
DUAL FLEX CONFIGURATIONS
“A” Configuration
The EM-A provides dual flex for wiring to both the fixture or ballast
compartment and test accessories.
“R” Configuration
I-13
The EM-R provides dual flex for wiring to the fixture or ballast compartment. The single-piece test accessory is provided with hardware
for installation directly within the reflector. (Recommended for OEM
installation only.)
NO-FLEX CONFIGURATIONS
650 LUMENS
I-26
650 LUMENS
LAMPS OPERATED
5, 7, 9, and 13 watt twin tube
2-pin with integral starter, 9W-13W
quad 2-pin with integral starter
LAMPS OPERATED
18 & 26 watt quad tube 2-pin
lamps with integral starter
INITIAL ILLUMINATION
1 lamp 650 lumens
90 Minutes
INITIAL ILLUMINATION
1 lamp 650 lumens
90 Minutes
CASE DIMENSIONS
9.5″ x 2.375″ x 1.5″ (Fig. B)
CASE DIMENSIONS
9.5″ x 2.375″ x 1.5″ (Fig. B)
WEIGHT
EM-A 4.4 lbs
EM-B 2.4 lbs
WEIGHT
EM-A 4.4 lbs
EM-B 2.4 lbs
“B” Configuration
The EM-B allows for integral installation within the ballast compartment. The EM-B may also be mounted atop the fixture when used with
a TMK-80 cover accessory.
“TM” Configuration
The EM-TM provides a top-mounting option for running wires directly
into the ballast compartment. Test accessories are then installed within
the fixture.
SINGLE FLEX CONFIGURATIONS
“J” Configuration
FLEXIBLE CONDUIT TO
TEST ACCESSORIES (36”)
WIRING TO
FIXTURE
The EM-J is designed to be mounted to the junction box and provides
flexible conduit for remote mounting of the test accessories.
“R-J” Configuration
Like the EM-J, the EM-R-J can be mounted to the junction box. The
single-piece test accessory is provided with hardware for installation
directly within the reflector. (Recommended for OEM installation only.)
8
IOTA ENGINEERING
FIG. B
SELF-DIAGNOSTICS
ISD Series emergency ballasts help ensure
compliance with national and local regulations
with automatic monthly and annual testing. ISD
Series ballasts utilize AC output for compatibility
with new lamp technologies.
ISD-80
1100 LUMENS
LAMPS OPERATED
Most 2′-4′ bipin T8,T12, and T5, HO
and VHO fluorescent lamps
INITIAL ILLUMINATION
1 lamp 1100 lumens
90 Minutes
CASE DIMENSIONS
13.3″ x 2.375″ x 1.5″ (Fig. D)
WEIGHT
3.6 lbs
ISD-420-EM-A 1100 LUMENS ISD-420-EM-B 1100 LUMENS
LAMPS OPERATED
10W-57W 4-pin rapid start compact lamps, including twin tube, triple tube, quad, 2D, and long
compact fluorescent lamps
LAMPS OPERATED
10W-57W 4-pin rapid start compact lamps, including twin tube, triple tube, quad, 2D, and long
compact fluorescent lamps
INITIAL ILLUMINATION
1 lamp 1100 lumens
90 Minutes
INITIAL ILLUMINATION
1 lamp 1100 lumens
90 Minutes
CASE DIMENSIONS
13.3″ x 2.375″ x 1.5″ (Fig. D)
CASE DIMENSIONS
13.3″ x 2.375″ x 1.5″ (Fig. D)
WEIGHT
5.6 lbs
WEIGHT
3.6 lbs
MONTHLY AND ANNUAL TESTING
FIG. D
The ISD Series emergency ballast will automatically conduct a 90-minute annual test and a short monthly 30-second test to determine the
status of the emergency system. These tests verify proper operation of
the ISD battery and charging circuit, as well as the condition of the designated emergency lamp. Should a failure occur in any of these areas,
the ISD will issue an alert and identify the nature of the problem through
a sequence of flashes on the indicator light.
LED RETROFIT
SOLUTIONS
AC output IOTA emergency ballasts are compatible and UL Listed for select
LED retrofit tube models. Visit www.iotaengineering.com/ledretrofit.htm for
current compatibility listings.
www.iotaengineering.com
9
COLD WEATHER - OUTDOOR EGRESS
ICE Series Cold-Weather Equipment provides necessary emergency lighting for outdoor paths of egress.
Designed to operate within -18° to 50° C, ICE Series
battery packs are ideal for covered walkways, parking
garages, and exit points.
ICE-80
1300 LUMENS
ICE-420-EM-A 1300 LUMENS ICE-420-EM-B 1300 LUMENS
LAMPS OPERATED
Most 2′-8′ single, bipin T8 through
T12, 2′-4′ T5, HO and VHO fluorescent lamps
LAMPS OPERATED
10W-70W 4-pin rapid start compact lamps, including twin tube, triple tube, quad, 2D, and long
compact fluorescent lamps
LAMPS OPERATED
10W-70W 4-pin rapid start compact lamps, including twin tube, triple tube, quad, 2D, and long
compact fluorescent lamps
INITIAL ILLUMINATION
1 (2′-8′) lamp 1300 lumens
2 (2′-4′) lamps 650 lumens each
90 Minutes
INITIAL ILLUMINATION
1 (10W-70W) lamp 1300 lumens
2 (10W-32W) lamps 650 lumens each
90 Minutes
INITIAL ILLUMINATION
1 (10W-70W) lamp 1300 lumens
2 (10W-32W) lamps 650 lumens each
90 Minutes
CASE DIMENSIONS
13.3″ x 2.375″ x 1.5″ (Fig. D)
CASE DIMENSIONS
13.3″ x 2.375″ x 1.5″ (Fig. D)
CASE DIMENSIONS
13.3″ x 2.375″ x 1.5″ (Fig. D)
WEIGHT
3.6 lbs
WEIGHT
5.6 lbs
WEIGHT
3.6 lbs
THERMAL HEAT BLANKET
The internal battery of the ICE Series emergency ballast is encased within an electrically-controlled thermal blanket. The heating element of
the blanket activates when conditions approach
freezing temperatures. This protects the battery
from being damaged by the extreme temperatures and ready to supply emergency illumination in the event of a power loss.
FIG. D
TEMPERATURE CONTROL CIRCUITRY
If the battery has been discharged for any reason, the Temperature
Control Circuitry of the ICE emergency ballast ensures that the battery reaches acceptable temperatures before supplying a charge in
order to prevent damage to the battery.
10
IOTA ENGINEERING
SPECIALTY PRODUCTS
LED RETROFIT SOLUTIONS
IOTA Emergency Ballasts that feature AC output
are compatible with most LED retrofit lamp designs and are UL Listed for select LED retrofit
lamp applications. Visit the LED Retrofit Selector
Tool at www.iotaengineering.com/ledretofit.htm
to find available IOTA emergency ballast and
LED lamp solutions.
ETS-20
and
ETS
EMERGENCY CONTROL DEVICES
The ETS-20 and ETS Emergency Control Devices
promote higher energy savings by allowing the use
of auxiliary generator or inverter power on switched
fixtures in power failure situations, eliminating the
need for ‘always on’ night lights. The ETS units
sense the loss of normal AC power and switch
to the auxiliary supply. Use the ETS for a single
switched fixture. For multiple fixture control and
dimming options, use the ETS-20 or ETS-20-DR
on a designated circuit up to 20 amps.
D-48-T EMERGENCY INVERTER BALLAST
The D-48-T operates without an internal battery,
and is used as an inverter unit for facilities such
as telephone operations buildings that have
central 48V battery systems. In power loss situations, the D-48-T will operate the lamp from the
48V supply. While in the emergency mode, the
D-48-T operates one of the lamps at full light
output for as long as the central 48V battery
supply is available.
OPEN BOARD DESIGNS
Open Board emergency ballast kits include the
circuit board with inverter and charger and separate battery pack. These kits are designed for
installation within sconces, wall packs and other
unusually shaped fixtures. The battery packs
are available in three configurations to accommodate the available fixture space.
COMPATIBLE MODELS
I-320 Reduced Profile
I-160 High Lumen Output
I-162 Parallel Operation
ISL-54 and ISL-540 Slim Profile
I-42 and I-420 for Compact Lamps
ISD Self-Diagnostic Series
LAMPS OPERATED
Allows operation of switched fixtures
from the generator or inverter supply.
INITIAL ILLUMINATION
Full light output
CASE DIMENSIONS
(ETS-20) 4.625″ x 2.25″ x 2.25″
(ETS) 8.0″ x 1.18″ x 1.125″
WEIGHT
(ETS-20) 1.0 lbs
(ETS) 1.0 lbs
LAMPS OPERATED
Most 2′-5′ single, bipin T8 & T12 HO
or VHO fluorescent lamps
INITIAL ILLUMINATION
Full light output
CASE DIMENSIONS
9.5″ x 2.375″ x 1.5″
WEIGHT
2.5 lbs
AVAILABLE MODELS
I-13-L ( for 2-Pin Compact Lamps)
I-42-L (for 4-Pin Compact Lamps)
BOARD DIMENSIONS
4.0″ x 2.75″ x 1.25″
BATTERY CONFIGURATIONS
Stick - 1.375″ x 1.375″ x 7.375″
Triangle - 2.4″ x 1.6″ x 2.5″
In-line - 1.25″ x 3.875″ x 2.5″
INTERNATIONAL
VOLTAGES
Select IOTA emergency ballasts are available
for various international voltage standards, such
as 220VAC and 240VAC input. Our international
voltage model selection includes emergency
ballasts for linear, compact and T5 fluorescent
lamp types and are available in a full range of
lumen output levels. For more information on
IOTA emergency ballasts for international voltages, contact our Customer Service team.
AVAILABLE VOLTAGES
220VAC, 50Hz
240VAC, 60Hz
120VAC, 50Hz
www.iotaengineering.com
11
TEST SWITCH AND CHARGE INDICATOR
The National Electric Code requires regular testing of emergency battery packs and written records of these tests to ensure the operation of emergency units in a power-loss situation. Test accessories are included with all IOTA emergency battery packs for compliance
with national and local regulations. Many IOTA battery packs offer a choice of test accessory styles for installation directly within the
fixture, reflector, or into a junction box within the wall or ceiling.
TBTS (THREADED BODY TEST SWITCH)
The TBTS option provides a single component for testing the emergency ballast and indicating the charge
status of the battery. The specialized design of the TBTS features a compact housing ideal for limited
compartment space. In normal operation, the TBTS will serve as a lit indication that the battery pack is
being charged. When the switch is pressed, the indicator light turns off, and the light fixture is forced into
the emergency mode. The smaller threaded body of the TBTS offers simpler installation in fixtures where
limited space prohibits the installation of a typical test switch and charge indicator. The TBTS is hardwired to the emergency ballast during installation and is secured in the fixture with an included hex nut.
TWO-PIECE TEST SWITCH AND CHARGE INDICATOR
The two-piece test kit configuration provides a separate test switch for wiring to the emergency ballast
and a red LED charge light for indicating that the battery pack is being charged. The test switch and
charge indicator can be mounted within the light fixture or remote mounted through flex to a junction box
adjacent to the fixture. Connection of the emergency ballast to the charge indicator is made via spade
terminals. Consult the wiring instructions of the particular emergency ballast for proper test switch
placement and installation.
DUAL COLOR LPTS
The Dual-Color LPTS (Lighted Push-Button Test Switch) provided with ISD Series self-diagnostic ballasts is a single component for testing the emergency ballast and indicating the charge status of the
battery. In normal operation, the LPTS will serve as a lit indication that the battery pack is being charged.
When the switch is pressed, the indicator light turns off, and the fixture is forced into the emergency
mode. The dual-color LED indicator is lit red when charging, and green when fully charged and in the
standby mode. Leads connect to the LPTS via two spade terminal connections.
OPTIONS AND FEATURES
DAMP LOCATION
LISTED
Select IOTA fluorescent emergency
ballasts are suitable for use in Damp
Location applications. Designed with
extra protection against damp and
humid environmental conditions, these
units provide emergency light in ambient temperatures of 0° to 50° Celsius.
DL units are available for linear, compact, and T5 fluorescent lamp types.
AVAILABLE UNITS
LINEAR
COMPACT
I-40
I-13
I-48
I-26
I-320
I-42
I-232
I-420
I-160
I-462
ISD SERIES
T5 OPERATION
ICE SERIES
ISL SERIES
12
IOTA ENGINEERING
ENCLOSED AND
GASKETED FIXTURES
Enclosed and Gasketed Fluorescent Fixtures provide additional protection against
contaminants in dirty, dusty, damp, and
wet operating environments. IOTA emergency ballasts that are indicated for use
in enclosed and gasketed fixtures meet
the requirements of compliance set forth
by U.L. and are acceptable for integral
installation within these fixtures.
AVAILABLE UNITS
LINEAR
I-40
I-48
I-232
ISD-80
ICE-80
COMPACT
I-13-EM-B
I-26-EM-B
I-42-EM-B
I-420-EM-B
ISD-420-EM-B
ICE-420-EM-B
RoHS COMPLIANCE
ON ALL MODELS
IOTA emergency ballast products are
designed and manufactured in compliance with adopted RoHS standards
to minimize environmental impact of
our electronic equipment through its
complete life-cycle - from the initial production process to end-of-life recycling.
The responsible design of IOTA’s emergency ballasts restricts the presence
of specified chemicals and substances
by utilizing quality-driven and verified
components that support both our
commitment to the environment and life
safety product performance.
ACCESSORIES
IOTA mounting accessories provide options for remote installation of the emergency ballast and test equipment, and to ensure
compliance with national and local safety requirements. For further details on IOTA mounting accessories, contact our Customer
Service team.
TMK-80, TMK-32 AND TMK-ISL
Use the TMK accessory when a unit is mounted on top of the fixture. To avoid exposed wiring when emergency battery packs are
top-mounted, the TMK is used to cover the wiring that goes from
the battery pack into the fixture. TMK models are available for standard profile (TMK-80), reduced profile (TMK-32), or slim profile
(TMK-ISL) units.
TMK-80
EMERGENCY
BALLAST
TMK-80 - 2.5″ x 2.5″ x 1.5″
TMK-32 - 2.5″ x 2.2″ x 1.15″
FIXTURE
TMK-ISL - 2.5″ x 1.18″ x 1.15″
TBMK MOUNTING KIT
Use the TBMK in instances where the battery pack cannot be
mounted on the light fixture, such as with downlight fixtures. The
battery pack is mounted on the TBMK, which is then mounted
on the T-bars of the ceiling grid. The battery pack is secured to
the TBMK with mounting clips. Wiring is then run to the fixture via
flexible conduit. The TBMK can accept any size IOTA emergency
battery pack, and can also be used in conjunction with the RME1
remote mounting enclosure.
CEILING GRID
I-160
TBMK
BAR
KIT CONSISTS OF:
MOUNTING
CLIPS
(2) 2-ft Mounting T-Bars
(4) Mounting Clips
REMOTE TEST KIT
TEST SWITCH and
CHARGE INDICATOR
The Remote Test Kit (RTK) allows for remote mounting of the test
switch and indicator light. The kit consists of 3 feet of flex, the junction box containing the test switch and charge indicator, and faceplate. Also available with TBTS test accessory (TBTS-RTK).
FACEPLATE
When ordering, specify which IOTA models are being equipped
with RTK accessories to ensure component compatibility.
FLEX TO
FIXTURE
JUNCTION BOX
RME1 REMOTE MOUNTING ENCLOSURE
The RME1 enclosure is the perfect size to accept most IOTA nonflexed battery packs for remote mounting. The emergency battery
pack is secured within the enclosure and wiring is routed through
the 2 feet of flexible conduit of the RME1 to the fixture.
ENCLOSURE
LID
RME1
ENCLOSURE DIMENSIONS
16.375″ x 3.0″ x 3.0″
EMERGENCY
BALLAST
FLEX TO
FIXTURE
www.iotaengineering.com
13
LUMEN REFERENCE CHART
REDUCED PROFILES
For shallow
compartments
IOTA MODEL
LAMP (# OF LAMPS)
F16 T8 (1)
F16 T8 (2)
F17 T8 (1)
F17 T8 (2)
F25 T8 (1)
F25 T8 (2)
F28 T8 (1)
F28 T8 (2)
F32 T8 (1)
F32 T8 (2)
F40 T8 (1)
F59 T8 (1)
FO96 T8 (1)
14W T5 (1)
21W T5 (1)
24W T5 (1)
28W T5 (1)
28W T5 (2)
35W T5 (1)
39W T5 (1)
47W T5 (1)
54W T5 (1)
54W T5 (2)
95W T5 (1)
17W T6 (1)
27W T6 (1)
30W T6 (1)
F15 T12
F20 T12 (1)
F20 T12 (2)
F40 T12 (1)
F40 T12 (2)
F48 T12 (1)
F96 T12 (1)
PARALLEL OPERATION
SELF-DIAGNOSTICS AND COLD WEATHER
Automatic Self-Testing Units
and Outdoor Battery Packs
Emergency illumination even
if one lamp is inoperable.
I-32 I-40 I-48 I-320 ISD-80 ICE-80 I-232 I-880 I-160 I-162 ISL-28 ISL-54 ISL-540 I-13 I-26 I-42 I-420
1125
1100
450 450 450 1125 780 1125
1600
1100 1000
650
2420
1200 1080 1200
1150
460 630 630 1215 1090 1215
1800
2700
1175 1260 1665
600
475 700 700 1350 1140 1350
2000 3060
3000
1350 1400 1850
675
320
650
950
360
650
950
380
630
990
425
700
1100
600
1150
450
500
450
800
700
850
700
1200
700
1300*
1100
825
1300
ISD-420
ICE-420
I-462
2835
675
850
1150
925
1050
500
740
990
900
970
1300
600
1650
375
425
500
500
1750
1450 2965
1050
2400
1100
1100 960 1100
2240
2650
1600 2630
1150 1190 1150
2500
2935
500
600
650
375
425 390 390
650
450 660 660
650
650
650
680
900
1030 1150
1150
1125
1600
1200 1575
2675
1575 2850
FOR QUESTIONS REGARDING LAMP OR LUMEN INFORMATION, CONTACT CUSTOMER SERVICE.
*Requires ISL-540 modified for 35W operation
The Lumen Reference Chart is your guide in selecting the right IOTA emergency ballast for your designated lamp type and
desired output level. Many IOTA units feature lamp selector leads which will optimize the lumen output of the designated
lamp(s) when operating during an emergency. Refer to the installation instructions of the specific IOTA unit to determine if
the selector leads should be connected or disconnected to achieve the best performance. For questions regarding particular lamps, contact IOTA Customer Service.
14
IOTA ENGINEERING
SLIM PROFILE
SELF-DIAGNOSTICS AND COLD WEATHER
For narrow ballast
compartments
Automatic Self-Testing Units
and Outdoor Battery Packs
IOTA MODEL
I-32 I-40 I-48
LAMP (# OF LAMPS)
18W Long Compact (1)
18W Long Compact (2)
24W Long Compact (1)
24W Long Compact (2)
25W Long Compact (1)
25W Long Compact (2)
28W Long Compact (1)
30W Long Compact (1)
36W Long Compact (1)
36W Long Compact (2)
39W Long Compact (2)
40W Long Compact (1) 450 600 600
40W Long Compact (2)
50W Long Compact (1)
625
50W Long Compact (2)
55W Long Compact (1)
650
7W PL CF 2-Pin (1)
9W PL CF 2-Pin (1)
13W PL CF 2-Pin (1)
18W PL CF 2-Pin (1)
26W PL CF 2-Pin (1)
13W PL CF 4-Pin (1)
13W PL CF 4-Pin (2)
18W PL CF 4-Pin (1)
18W PL CF 4-Pin (2)
26W PL CF 4-Pin (1)
26W PL CF 4-Pin (2)
32W PL CF 4 Pin (1)
32W PL CF 4 Pin (2)
42W PL CF 4 Pin (1)
42W PL CF 4 Pin (2)
57W PL CF 4 Pin (1)
70W PL CF 4 Pin (1)
9W Circline (T5)
12W Circline (T5)
20W Circline (1)
625 390
22W Circline T9 (1)
400
22W Circline T5 (1)
425
40W Circline T8 (1)
450 650 650
40W Circline T5 (1)
650
55W Circline T5 (1)
650
F282 D/42 (1)
F282 D/42 (2)
F382 D/42 (1)
F382 D/42 (2)
PARALLEL OPERATION
Emergency illumination even
if one lamp is inoperable.
I-320 ISD-80 ICE-80 I-232 I-880 I-160 I-162 ISL-28 ISL-54 ISL-540 I-13 I-26
I-42
710
500
860
575
I-420
ISD-420 ICE-420 I-462
850
1120
1200
1485
1600
2300
1160
2300
1120 1050
675
1025
650
1500
1450
1120 1050
1500
675
1025
650
1000
650
1000
1900
1120 1100
1525 2300
1100 1100
1600
1700
1900
1700
350
500
650
550
650
935
955
1070
1125
1800
1275
1500
1550
1160
1750
1110
600
570
900
680
1010
810
1200
910
750
1040
1060
1180
1190
350
400
350
550
425
740
780
1000
1060
600
675
600
950
725
1200
1050
1250
1300
1000
1150
1300
1450
1850
1160
1200
1600
1680 1725
1160
1200
970
1100
1125
730
425
1125
650
980
475
500
500
650
800
850
850
1125
www.iotaengineering.com
15
IOTA Engineering is dedicated to providing
products that meet the standards our customers
demand as well as the superior service they deserve.
All IOTA products receive 100% quality inspection before shipment to ensure proper and
satisfactory operation. IOTA warranties all emergency battery packs in the continental
United States and Canada from defects in materials or workmanship under normal use
for five years from date of retail purchase and will repair or replace any IOTA product
found to be defective in materials or workmanship free of charge.
For additional information on IOTA’s fluorescent emergency ballasts and other emergency
lighting solutions, visit us at www.iotaengineering.com. Our website features the latest
up-to-date information for comparing models, specifying products, or assisting with installation. Our online Technical Library puts you one click away from dozens of IOTA
Specification Sheets and Installation Manuals, in addition to an extensive collection of
product wiring diagrams – all in PDF format for easy printing. And sign up for news email to stay current on the latest in product offerings and design enhancements for your
emergency lighting options! Need some additional assistance? You can easily contact
your Customer Service Representative from our IOTA Contacts page. Bookmark us at
www.iotaengineering.com!
DISTRIBUTED BY:
P.O. BOX 11846 TUCSON, AZ 85734
1361 E. WIEDING ROAD TUCSON, AZ 85706
1-800-866-4682 • FAX (520) 741-2837
www.iotaengineering.com
Find us on
Facebook
REV 022916
YouTube
LinkedIn
© IOTA Engineering, L.L.C. 2016. All Rights Reserved.