MG100395 - BANCO DI COLLAUDO PER MANIFOLD E SISTEMI

Transcription

MG100395 - BANCO DI COLLAUDO PER MANIFOLD E SISTEMI
The experimental bench for testing manifold and integrated systems are able to
run tests on groups of manifold valves
assembled manually operated witnessed.
The system is capable of achieving a
maximum pressure of 350 bar.
The access to the test area is regulated
by a microswitch that allows access to
the compartment only in conditions of
safety for the operator.
The bench has an architecture which is formed by:

Pulpit control of the bench: in the pulpit were placed on the PC for the management / control of the bench, the hand control for electric drives used in the testing phase.

Test space for manifold: in the test chamber manifold the operator performs the steps of
connection / disconnection of piping and electrical connections. The compartment is equipped with a rotary table and a frontal protection, connected to a safety microswitch.

The front panel houses the hydraulic motors (protected by Lexan) for the simulation, together with the cylinders, of the various application it is intended for the testing group.

Test system: on the right and left sides, are positioned to view (protected by Lexan), the stems
of the cylinders matched to the test system of
the bench, manual adjustments of the loads applied to the cylinders, and potentiometers of proportional valves slaved .
ST024-M-10
Tank
250 lt
Pmax
350 bar
Power
70 kW
Max oil temp.
Viscosity of oil to use
Filtration supercharging system
Off-line filtration
PC + Report
65° C
32 - 68 cSt
6 µm
6 µm
On board
Special Requirements
Size
2900 mm x 2400 mm x 2450 mm
Optional:


Flow meters on each line;
Remote control.
Dry Weight
Supply Voltage
325 kg
300/400 V
Frequency
50 Hz
Max Current
13,4 A
Cooling capacity (nominal)
Max power consumption
Temp. range
Pressure of fluid range
Tank
16.000 W
7,7 kW
10 - 43 °C
1,5 – 2,5 bar
80 l
Noise Level
Class of protection
69 dB (A)
44 IP
Optional:

Energy recovery.
System Development
Type of communication
Type of saving
Video resolution
N.I. Labview 11 withNI-DAQmx v9.4
Ethernet for communication with TURCK for Digital signals
(Ethernet Dedicated)
USB bus on NI cards for the management of analog signals
File structure
1280x1024
ST024-M-10
The automation of the cycle is guaranteed by the PLC and industrial PC integrated into the
structure. The software allows a variety of test configurations, displaying the performance of
the test both graphically and numerically.
Full management through
software OilSafe
Settings for test
ST024-M-10
A particular aspect is the management of the
testing sequence that occurs in wizard mode to
assist the operator with the automatic control to
achieve the set parameters.
Macros are also available for the automatic management of some phases of testing.
The configuration parameters can be set at will
by changing the sequences, the equipment available, etc. in order to guarantee maximum flexibility in testing fully satisfying the specific needs
of each customer
On a specific panel gauges are available which ensure the control of the
pressure transducers and the attacks of the various utilities available.
ST024-M-10