Slit Lamp Adapters (SLA)

Transcription

Slit Lamp Adapters (SLA)
Slit Lamp Adapters (SL A )
Incorporate Advanced Laser Therapy Capabilities to Your Slit Lamp
TxCell Scanning Laser
Delivery System
™
Haag-Streit® Style
Zeiss® Style
Intelligent and Intuitive Design
Predictability of Laser Delivery
TxCell with IQ 532™ or IQ 577™ Laser
Target Cell technology enables physicians to
visualize the perimeter of the targeted area. Optimal
for subvisible MicroPulse protocols.
°
Single and multi-spot pattern delivery using standard continuous-wave or MicroPulse® treatment modes
° Short pulse durations for efficient laser delivery
° Multi-spot patterns offer confluent spot (zero spacing) ideal for MicroPulse protocols
° Rotatable patterns to designate treatment starting point
° Automated FiberCheck to confirm fiber integrity
° Dual port for efficient setup of alternate delivery devices
° Intuitive graphical touch-screen interface for ease of use
° Programmable user preset menu (up to 10 presets)
° Full-featured remote control and wireless footswitch*
Pattern Selection Types
Visible Target Cells
Grid
(Adjustable grid
from 2x2 to 7x7)
™
Circle
(Adjustable radius)
Triple Arc
(Adjustable radius
& arc)
*Optional
Delivered Laser Spots
Standard SL A
Standard Adapters
Parfocal adjustment offers precise focus and uniform energy density
° across
the spot
° Unmatched optics, accuracy, and convenience
Rugged, durable, slim, all-metal design promotes easy installation and
° long-term
reliability
600-5000 µm spot sizes available with large spot adapters - Larger Spot
° available
for Transpupillary Thermotherapy (TTT)
°
FiberCheck™ available to confirm fiber integrity (only on select models)
FiberCheck Lever
EasyView™ Slit Lamp Adapter For Unobstructed Diagnostic View
on Haag-Streit Style
°
aser delivery mirror rotates out of optical viewing path for accurate
L
diagnosis without the need for a dedicated lamp
°
Improved optics promote superior viewing of target tissue during
treatment and maximum resolution, delivery, and color balance
°
°
50–500 µm spot sizes
Includes micromanipulator for precise laser positioning
EasyView
EasyFit™ Adapters For Unobstructed Diagnostic View on Zeiss Style
°
onvenient flip-in/flip-out eye safety filter provides an unobstructed
C
view of the ocular anatomy and eliminates the need for an electric
shutter filter
°
Improved optics promote superior viewing of target tissue during
treatment and maximum resolution, delivery, and color balance
°
°
50–500 µm spot sizes
Includes micromanipulator for precise laser positioning
Multi-Wavelength
Symphony SL A
™
odular design combines the power and flexibility of IRIDEX visible
° Mand
infrared laser systems
°
tilize your existing compatible IRIDEX lasers or add to expand your
U
treatment options
°
°
Quickly and easily switches between desired wavelengths
Compatible with most Zeiss-style slit lamps
EasyFit
Slit Lamp Adapters
Specifications
SLA Style Spot Sizes Console Compatibility Slit Lamp Compatibility
TxCell™
50–500 µm
IQ 532™/IQ 577™
Haag-Streit/Zeiss-style
Standard 50–500 µm OcuLight® GL/GLx/TX IQ 532/IQ 577
Haag-Streit-style
EasyView™
50–500 µm
OcuLight GLx/TX
IQ 532/IQ 577
Haag-Streit-style
EasyFit™ 50–500 µm OcuLight GLx/TX IQ 532/IQ 577
Zeiss-style
Standard 810 nm 75–500 µm OcuLight SL/SLx/IQ 810™
Haag-Streit-style
Large Spot 810 nm*
600–5000 µm OcuLight SL/SLx/IQ 810
Haag-Streit/Zeiss-style
FiberCheck™
Standard Large Spot 75 –500 µm 600–5000 µm IQ 810 IQ 810
Haag-Streit/Zeiss-style
Haag-Streit/Zeiss-style
Symphony™ 2
Combinations available: 810 nm & 532 nm** ; 810 nm & 577 nmZeiss-style
810 nm
125–1000 µm
IQ 810/OcuLight SLx
532 nm 50– 500 µm OcuLight GLx/TX 577 nm 50– 500 µm IQ 577
Note: The self-centering micromanipulator is standard on Zeiss-style adapters and an option for Haag-Streit styles.
Contact customer service for additional SLA compatibility information.
LASER RADIATION
AVOID EYE OR SKIN EXPOSURE TO
DIRECT OR SCATTERED RADIATION
CLASS 4 LASER PRODUCT
CLASS 2 LASER PRODUCT
(IEC 60825-1:2007)
*Factory installed option
**Not available for IQ 532
MicroPulse® Compatible Lasers: IQ 810, IQ 577, IQ 532, and OcuLight SLx
Specifications are subject to change without notice. IRIDEX, the IRIDEX logo, MicroPulse and OcuLight are registered trademarks
and TxCell, EasyView, EasyFit, Symphony, IQ 810, IQ 532, IQ 577 and FiberCheck are trademarks of IRIDEX Corporation. All other
trademarks are the property of their respective owners.
Products are covered by one or more of the following U.S. patents: 5,511,085; 5,982,789; 6,327,291; 6,540,391; 6,733,490; 7,766,904;
7,771,417; 7,909,816; 5,997,498; 6,073,759; 6,092,898; 6,217,594; 6,494,314; 6,585,679; 6,726,666; 6,800,076; 6,866,142;
7,537,593; 8,177,777; 783783; 69530497.6; KR 348012; 0904615; 69706541.3; CA 2331837; AU 759193; JP 4149670; EP 1009684;
CA 2286002; JP 449444; JP 4570696; JP 4819754; JP 5123973; JP 5133069.
Other U.S. and international patents pending.
EC
REP
Emergo Europe
Molenstraat 15, 2513 BH, The Hague,
The Netherlands,
Tel.: (31) (0) 70 345-8570, Fax: (31) (0) 70 346-7299
λ = 577 nm
λ = 635 nm
PO = 5 W
PO = 1 mW
VISIBLE AND INVISIBLE LASER RADIATION
AVOID EYE OR SKIN EXPOSURE TO
DIRECT OR SCATTERED RADIATION
CLASS 4 LASER PRODUCT
CLASS 2 LASER PRODUCT
(IEC 60825-1:2007)
λ = 810 nm
λ = 650 nm
PO = 4 W
PO = 1 mW
LASER RADIATION
AVOID EYE OR SKIN EXPOSURE TO
DIRECT OR SCATTERED RADIATION
CLASS 4 LASER PRODUCT
CLASS 2 LASER PRODUCT
(IEC 60825-1:2007)
λ = 532 nm
λ = 635 nm
PO = 5 W
PO = 1 mW
LASER RADIATION
AVOID EYE OR SKIN EXPOSURE TO
DIRECT OR SCATTERED RADIATION
CLASS 4 LASER PRODUCT
CLASS 2 LASER PRODUCT
(IEC 60825-1:2007)
λ = 532 nm
λ = 635 nm
©2014 IRIDEX. Printed in U.S.A. LT0010 12/2014
PO = 3 W
PO = 1 mW

Similar documents

IQ 810™ Laser System

IQ 810™ Laser System Portable SLA: 0–1300 mW LIO: 0–1500 mW LIO-LS: 0–1500 mW EndoProbe®: 0–1500 mW G-Probe™: 0–2000 mW DioPexy™: 0–1800 mW OMA: 0–1300 mW

More information

Brochure

Brochure SLA: 0–2000 mW LIO: 0–2000 mW LIO-LS: 0-2000 mW EndoProbe: 0–2000 mW G-Probe: 0-3000 mW DioPexy: 0-2000 mW OMA: 0-2000 mW

More information

IQ 577™ Laser System

IQ 577™ Laser System LIO: 0–2000 mW EndoProbe®: 0–2000 mW

More information

IQ 532™ Laser System

IQ 532™ Laser System IRIDEX, the IRIDEX logo, and MicroPulse are registered trademarks and TxCell, IQ 532, DualSense, OtoProbe, and CW-Pulse are trademarks of IRIDEX Corporation. All other trademarks are the property o...

More information

SLA Operator Manual

SLA Operator Manual SLAs feature parfocal adjustment of all spot sizes for precise focus and consistent burns, a transparent, integral eye safety filter (ESF), and on some models, a micromanipulator. This manual provi...

More information