F I V E WAY S T O R E D U C E T H E C O S T O F O W N E R S H I P
NO HIDDEN INSTALLATION COSTS
WITH QUIET AIR-COOLING
SAFETY SECOND TO NONE
The Ultima 2000 SE requires no special
state-of-the-art power supply ensure accura-
plumbing.
cy of exposure time and treatment power.
Quiet variable speed fans are
actuated only when cooling is required.
There is no special power requirement.
The dual-channel computer system and the
The Ultima 2000 SE has been approved by
safety agencies worldwide.
Simply plug the laser into any standard wall
NO LIMIT TO YOUR
TREATMENT OPTIONS
outlet.
The Ultima SE is flexible in meeting the
NO UNNECESSARY COSTS OF AN
ADDITIONAL LASER ROOM
The LaserLink slit lamp adapter can be used
with the diagnostic slit lamp you already
own. The laser console moves easily out of
the way,
allowing the ophthalmologist to
use the Ultima 2000 SE in even the smallest
treatment lane.
the Ultima 2000 SE to a variety of Lumenis
delivery systems to meet a specific clinical
requirement. With the accessory module
both the Laser Indirect Ophthalmoscope and
the Acculite endoprobe may be utilized.
There is no risk of obsolescence. The efficacy
of the argon laser has been proven in over
NO FINANCIAL RISKS WITH
A LUMENIS FIVE-YEAR
TUBE GUARANTEE
With Lumenis’ patented Power On Demand
technology, the Ultima 2000 SE offers virtually unlimited tube life by energizing the
laser only during each individual exposure.
Typical running time is less than one minute
per patient.
Specifications
Lumenis Inc.
2400 Condensa Street
Santa Clara, CA 95051 USA
Tel 408 764 3000
800 635 1313
Fax 408 764 3999
800 505 1133
Laser System
Lumenis (HOLLAND) BV
Amstelveen, The Netherlands
Tel + 31 20 347 50 60
Fax + 31 20 347 50 99
20 years of clinical use. As applications of the
argon laser continue to expand, utilization
of your laser will only increase.
Lumenis INNOVA® metal / ceramic Power On Demand™ plasma tube
Wavelength
Argon all lines: blue-green 488 nm - 528 nm
Argon green: 514nm, 528 nm
Power to the Cornea
1.5 watts of blue-green; 0.80 watts of green
Exposure Time
0.01, 0.02, 0.05, 0.07, 0.1, 0.15, 0.2, 0.3, 0.4, 0.5, 0.7, 1.0 seconds
Repeat Mode
Up to 3 Hz
Weight
65 lbs. (30 kg)
Dimensions
Console 8” W x 24 “ L x 18.5” H (20cm W x 61cm L x 47cm H)
100 - 120 VAC, 50/60 Hz, 15 or 20 amps
Forced Air
Aiming Beam
Red diode, adjustable intensity
Delivery System Options
Lumenis LaserLink™ slit lamp adapter attaches to these slit lamps:
Haag-Streit 900 BQ, Haag-Streit 900 BM, Haag-Streit 900 CN,
Topcon SL-3E, 5E, 7E, Marco V, Mentor SH-12, Nikon NS-1,
Nikon NS-3, Zeiss 20 SL, Zeiss 30 SL, Zeiss 125 SL, Zeiss SL-130
Lumenis Indirect Ophthalmoscope:
modified Keeler Fison headpiece at 1.2 lbs (545 gms);
spot size is 350 microns at focus
Lumenis (ITALY) Srl.
Rome, Italy
Tel + 39 06 90 75 230
Fax + 39 06 90 75 269
Acculite™ endoprobe accessory:
sterile; single-use straight or angled sterile 20-guage probes;
2-meter fiber
Lumenis (UK) Ltd.
London, UK
Tel + 44 20 8324 4200
Fax + 44 20 8324 4222
Ultima accessory module:
Laser Indirect Ophthalmoscope illumination power supply /
booster; dual eye physician filter drivers for Acculite endoprobe
or LaserLink Z slit lamp adapter.
Combination System
Compatible with the portable EPIC™
Q-switched Nd:YAG laser system
Electrical Certification
ETL listed to UL 544; CE Mark for medical devices
Quality Standards
ISO9001, EN46001
Lumenis (JAPAN) Co. Ltd.
Tokyo, Japan
Tel + 81 3 5789 8300
Fax + 81 3 5789 8310
Portable Argon Laser Photocoagulator
LUMENIS
CUSTOMER CARE
Worry-Free
Lumenis (HK) Ltd.
Kowloon, Hong Kong
Tel + 852 2174 2800
Fax + 852 2722 5151
Ultima 2000 SE
220 - 240 VAC, 50/60 Hz, 10 amps, single phase
Cooling
Lumenis (FRANCE) SARL
Suresnes, France
Tel + 33 1 41 44 99 99
Fax + 33 1 47 28 99 09
Lumenis Ltd.
Yokneam, Israel
Tel + 972 4 959 9000
Fax + 972 4 959 9050
®
Remote control 4” W x 6” L x 1.25” H (10cm W x 15cm L x 3cm H)
Power Requirements
Lumenis (GERMANY) GmbH
Dieburg, Germany
Tel + 49 6071 922 0
Fax + 49 6071 922 400
needs for both office and operating room
use. The available accessory module adapts
Argon Laser Photocoagulator
Service
and
Support
At Lumenis we understand the importance of delivering service and technical support of the highest quality.
When you buy a laser or light-based system from Lumenis, you make an investment in the world's most innovative medical technology in its category — backed by the most comprehensive service and support organization in
the industry. Customer satisfaction is paramount and the ultimate goal of our business.
Lumenis (HOLLAND) BV
Beijing Office
Beijing, China
Tel + 86 10 6510 2620
Fax + 86 10 6510 2621
LASER CLASS 4/IV
Argon Ion Laser: 476-529 nm, 3 W Max, CW
LASER CLASS 2/II
Diode Laser: 670 nm, 4 mW Max., CW
Lumenis (SWEDEN) AB
Kristianstad, Sweden
Tel + 46 44 21 21 26
Fax + 46 44 21 21 79
internet:
www.ophthalmic.lumenis.com
email: information@lumenis.com
VISIBLE LASER RADIATION
AVOID EYE OR SKIN EXPOSURE TO
DIRECT OR SCATTERED RADIATION
CLASS 4 LASER PRODUCT per EN 60825-1/1994
CLASS IV LASER PRODUCT per 21 CFR 1040
93/42/EEC
0086
EN
4
6
0
0
1
REGISTERED
Lumenis and its logo, and INNOVA, Ultima, Acculite,
LaserLink, SureSpot, and Power On Demand are trademarks or registered trademarks of the Lumenis group of
companies. Copyright © 2002, the Lumenis group of companies. Product specifications are subject to change without
notice. Caution: U.S. law restricts this device to sale by or on
the order of a physician. All rights reserved.
Printed in USA. 3/0210M
PBE000006
Formerly
Coherent Medical Group
and ESC Sharplan
Ultima SE
Ultima® 2000 SE
F I V E WAY S T O R E D U C E T H E C O S T O F O W N E R S H I P
NO HIDDEN INSTALLATION COSTS
WITH QUIET AIR-COOLING
SAFETY SECOND TO NONE
The Ultima 2000 SE requires no special
state-of-the-art power supply ensure accura-
plumbing.
cy of exposure time and treatment power.
Quiet variable speed fans are
actuated only when cooling is required.
There is no special power requirement.
The dual-channel computer system and the
The Ultima 2000 SE has been approved by
safety agencies worldwide.
Simply plug the laser into any standard wall
NO LIMIT TO YOUR
TREATMENT OPTIONS
outlet.
The Ultima SE is flexible in meeting the
NO UNNECESSARY COSTS OF AN
ADDITIONAL LASER ROOM
The LaserLink slit lamp adapter can be used
with the diagnostic slit lamp you already
own. The laser console moves easily out of
the way,
allowing the ophthalmologist to
use the Ultima 2000 SE in even the smallest
treatment lane.
the Ultima 2000 SE to a variety of Lumenis
delivery systems to meet a specific clinical
requirement. With the accessory module
both the Laser Indirect Ophthalmoscope and
the Acculite endoprobe may be utilized.
There is no risk of obsolescence. The efficacy
of the argon laser has been proven in over
NO FINANCIAL RISKS WITH
A LUMENIS FIVE-YEAR
TUBE GUARANTEE
With Lumenis’ patented Power On Demand
technology, the Ultima 2000 SE offers virtually unlimited tube life by energizing the
laser only during each individual exposure.
Typical running time is less than one minute
per patient.
Specifications
Lumenis Inc.
2400 Condensa Street
Santa Clara, CA 95051 USA
Tel 408 764 3000
800 635 1313
Fax 408 764 3999
800 505 1133
Laser System
Lumenis (HOLLAND) BV
Amstelveen, The Netherlands
Tel + 31 20 347 50 60
Fax + 31 20 347 50 99
20 years of clinical use. As applications of the
argon laser continue to expand, utilization
of your laser will only increase.
Lumenis INNOVA® metal / ceramic Power On Demand™ plasma tube
Wavelength
Argon all lines: blue-green 488 nm - 528 nm
Argon green: 514nm, 528 nm
Power to the Cornea
1.5 watts of blue-green; 0.80 watts of green
Exposure Time
0.01, 0.02, 0.05, 0.07, 0.1, 0.15, 0.2, 0.3, 0.4, 0.5, 0.7, 1.0 seconds
Repeat Mode
Up to 3 Hz
Weight
65 lbs. (30 kg)
Dimensions
Console 8” W x 24 “ L x 18.5” H (20cm W x 61cm L x 47cm H)
100 - 120 VAC, 50/60 Hz, 15 or 20 amps
Forced Air
Aiming Beam
Red diode, adjustable intensity
Delivery System Options
Lumenis LaserLink™ slit lamp adapter attaches to these slit lamps:
Haag-Streit 900 BQ, Haag-Streit 900 BM, Haag-Streit 900 CN,
Topcon SL-3E, 5E, 7E, Marco V, Mentor SH-12, Nikon NS-1,
Nikon NS-3, Zeiss 20 SL, Zeiss 30 SL, Zeiss 125 SL, Zeiss SL-130
Lumenis Indirect Ophthalmoscope:
modified Keeler Fison headpiece at 1.2 lbs (545 gms);
spot size is 350 microns at focus
Lumenis (ITALY) Srl.
Rome, Italy
Tel + 39 06 90 75 230
Fax + 39 06 90 75 269
Acculite™ endoprobe accessory:
sterile; single-use straight or angled sterile 20-guage probes;
2-meter fiber
Lumenis (UK) Ltd.
London, UK
Tel + 44 20 8324 4200
Fax + 44 20 8324 4222
Ultima accessory module:
Laser Indirect Ophthalmoscope illumination power supply /
booster; dual eye physician filter drivers for Acculite endoprobe
or LaserLink Z slit lamp adapter.
Combination System
Compatible with the portable EPIC™
Q-switched Nd:YAG laser system
Electrical Certification
ETL listed to UL 544; CE Mark for medical devices
Quality Standards
ISO9001, EN46001
Lumenis (JAPAN) Co. Ltd.
Tokyo, Japan
Tel + 81 3 5789 8300
Fax + 81 3 5789 8310
Portable Argon Laser Photocoagulator
LUMENIS
CUSTOMER CARE
Worry-Free
Lumenis (HK) Ltd.
Kowloon, Hong Kong
Tel + 852 2174 2800
Fax + 852 2722 5151
Ultima 2000 SE
220 - 240 VAC, 50/60 Hz, 10 amps, single phase
Cooling
Lumenis (FRANCE) SARL
Suresnes, France
Tel + 33 1 41 44 99 99
Fax + 33 1 47 28 99 09
Lumenis Ltd.
Yokneam, Israel
Tel + 972 4 959 9000
Fax + 972 4 959 9050
®
Remote control 4” W x 6” L x 1.25” H (10cm W x 15cm L x 3cm H)
Power Requirements
Lumenis (GERMANY) GmbH
Dieburg, Germany
Tel + 49 6071 922 0
Fax + 49 6071 922 400
needs for both office and operating room
use. The available accessory module adapts
Argon Laser Photocoagulator
Service
and
Support
At Lumenis we understand the importance of delivering service and technical support of the highest quality.
When you buy a laser or light-based system from Lumenis, you make an investment in the world's most innovative medical technology in its category — backed by the most comprehensive service and support organization in
the industry. Customer satisfaction is paramount and the ultimate goal of our business.
Lumenis (HOLLAND) BV
Beijing Office
Beijing, China
Tel + 86 10 6510 2620
Fax + 86 10 6510 2621
LASER CLASS 4/IV
Argon Ion Laser: 476-529 nm, 3 W Max, CW
LASER CLASS 2/II
Diode Laser: 670 nm, 4 mW Max., CW
Lumenis (SWEDEN) AB
Kristianstad, Sweden
Tel + 46 44 21 21 26
Fax + 46 44 21 21 79
internet:
www.ophthalmic.lumenis.com
email: information@lumenis.com
VISIBLE LASER RADIATION
AVOID EYE OR SKIN EXPOSURE TO
DIRECT OR SCATTERED RADIATION
CLASS 4 LASER PRODUCT per EN 60825-1/1994
CLASS IV LASER PRODUCT per 21 CFR 1040
93/42/EEC
0086
EN
4
6
0
0
1
REGISTERED
Lumenis and its logo, and INNOVA, Ultima, Acculite,
LaserLink, SureSpot, and Power On Demand are trademarks or registered trademarks of the Lumenis group of
companies. Copyright © 2002, the Lumenis group of companies. Product specifications are subject to change without
notice. Caution: U.S. law restricts this device to sale by or on
the order of a physician. All rights reserved.
Printed in USA. 3/0210M
PBE000006
Formerly
Coherent Medical Group
and ESC Sharplan
Ultima SE
multiple treatment modalities
F O R T H E O F F I C E A N D T H E O P E R AT I N G R O O M
V E R S AT I L I T Y T O M E E T A N Y C L I N I C A L N E E D
LASERLINK TRANSFORMS
YOUR SLIT LAMP INTO A LASER
DELIVERY SYSTEM
LASER INDIRECT
OPHTHALMOSCOPE:
THE CHOICE OF SPECIALISTS
The LaserLink slit lamp adapter is compatiThe LIO is designed for the ophthalmoloble with most diagnostic slit lamps.
The
gist’s comfort and safety as well as for pre-
Ultima 2000 SE adapts easily to your
cise laser delivery. The unique high-visibilfavorite slit lamp without compromising its
ity filter is always in place. The fixed filter
normal operation. Any exam lane can be
provides eye protection at all times and
utilized.
eliminates heavy, cumbersome mechanical shutters. As a result, the headset is
lightweight,
minimizing fatigue during
long procedures.
EASY, REPEATABLE ALIGNMENT
The LaserLink’s rugged adapter attaches to
the tonometer mount and assures precise
EXPANDING TREATMENT OPTIONS
focus of the laser and parfocality with the
The LIO is indicated for treating difficult
slit lamp.
cases such as infants or physically disabled
patients.
Excellent access to the far
periphery makes the LIO ideal for diabetic
retinopathy, retinal tears and retinal
detachment. Since no contact lens is nec-
YOU’RE IN CONTROL
essary, it is also suitable for patients with
The SureSpot™ telescope with sharprecent ocular surgery.
edged,
defocused spot allows a well-
defined spot on the retina with the assurThe Ultima 2000 SE addresses a broad range of clinical needs. Photocoagulation in the anterior or posteri-
ance of minimal power density to the
or chamber is accomplished with the LaserLink™ slit lamp adapter for existing Haag-Streit slit lamps or with
Lumenis’s complete line of dedicated slit lamp delivery systems offering both mechanical and electronic
micromanipulators for additional precision. Endophotocoagulation with Lumenis Acculite™ single-use
cornea or crystalline lens. The continuously
adjustable spot size selector is equipped
endoprobes is also possible. For treatment of the supine patient or infant, Lumenis’ proven Laser Indirect
with detents in the range of 50 to 500
Ophthalmoscope may be used. For each indication the delivery device of choice is available without com-
microns. Uniform burns and a well defined
promise.
aiming beam ensure a more rapid,
Each delivery system is designed for precise therapy with convenient operation and safety. For example, the fixed high-visibility physician filter on the LaserLink and the LIO provides dependable protection
for the ophthalmologist’s eyes and a clear view of the treatment site. Silent operation with no shutter
treatment.
safe
The remote control panel can be
The accessory module connects
The LaserLink provides clear
placed on the table on either side
the Ultima 2000 SE with mutiple
of the slit lamp, on the Ultima
delivery systems. It drives the
vision even in the far periphery.
The
accessory module, or on the oper-
selectable dual eye safety filters
unique dichroic laser mirror coaxially
ating room table instrument tray.
for the Acculite endoprobe and
reflects the laser beam while maintaining
The back-lit panel is easy to read,
provides illumination control for
clear illumination of the fundus.
even in a darkened treatment
the
room.
Illumination of the control panel
movement avoids patient anticipation of the treatment and consequent involuntary eye motion.
LIO.
Easy
simplify operation.
access
and
Ultima SE
multiple treatment modalities
F O R T H E O F F I C E A N D T H E O P E R AT I N G R O O M
V E R S AT I L I T Y T O M E E T A N Y C L I N I C A L N E E D
LASERLINK TRANSFORMS
YOUR SLIT LAMP INTO A LASER
DELIVERY SYSTEM
LASER INDIRECT
OPHTHALMOSCOPE:
THE CHOICE OF SPECIALISTS
The LaserLink slit lamp adapter is compatiThe LIO is designed for the ophthalmoloble with most diagnostic slit lamps.
The
gist’s comfort and safety as well as for pre-
Ultima 2000 SE adapts easily to your
cise laser delivery. The unique high-visibilfavorite slit lamp without compromising its
ity filter is always in place. The fixed filter
normal operation. Any exam lane can be
provides eye protection at all times and
utilized.
eliminates heavy, cumbersome mechanical shutters. As a result, the headset is
lightweight,
minimizing fatigue during
long procedures.
EASY, REPEATABLE ALIGNMENT
The LaserLink’s rugged adapter attaches to
the tonometer mount and assures precise
EXPANDING TREATMENT OPTIONS
focus of the laser and parfocality with the
The LIO is indicated for treating difficult
slit lamp.
cases such as infants or physically disabled
patients.
Excellent access to the far
periphery makes the LIO ideal for diabetic
retinopathy, retinal tears and retinal
detachment. Since no contact lens is nec-
YOU’RE IN CONTROL
essary, it is also suitable for patients with
The SureSpot™ telescope with sharprecent ocular surgery.
edged,
defocused spot allows a well-
defined spot on the retina with the assurThe Ultima 2000 SE addresses a broad range of clinical needs. Photocoagulation in the anterior or posteri-
ance of minimal power density to the
or chamber is accomplished with the LaserLink™ slit lamp adapter for existing Haag-Streit slit lamps or with
Lumenis’s complete line of dedicated slit lamp delivery systems offering both mechanical and electronic
micromanipulators for additional precision. Endophotocoagulation with Lumenis Acculite™ single-use
cornea or crystalline lens. The continuously
adjustable spot size selector is equipped
endoprobes is also possible. For treatment of the supine patient or infant, Lumenis’ proven Laser Indirect
with detents in the range of 50 to 500
Ophthalmoscope may be used. For each indication the delivery device of choice is available without com-
microns. Uniform burns and a well defined
promise.
aiming beam ensure a more rapid,
Each delivery system is designed for precise therapy with convenient operation and safety. For example, the fixed high-visibility physician filter on the LaserLink and the LIO provides dependable protection
for the ophthalmologist’s eyes and a clear view of the treatment site. Silent operation with no shutter
treatment.
safe
The remote control panel can be
The accessory module connects
The LaserLink provides clear
placed on the table on either side
the Ultima 2000 SE with mutiple
of the slit lamp, on the Ultima
delivery systems. It drives the
vision even in the far periphery.
The
accessory module, or on the oper-
selectable dual eye safety filters
unique dichroic laser mirror coaxially
ating room table instrument tray.
for the Acculite endoprobe and
reflects the laser beam while maintaining
The back-lit panel is easy to read,
provides illumination control for
clear illumination of the fundus.
even in a darkened treatment
the
room.
Illumination of the control panel
movement avoids patient anticipation of the treatment and consequent involuntary eye motion.
LIO.
Easy
simplify operation.
access
and
Ultima SE
multiple treatment modalities
F O R T H E O F F I C E A N D T H E O P E R AT I N G R O O M
V E R S AT I L I T Y T O M E E T A N Y C L I N I C A L N E E D
LASERLINK TRANSFORMS
YOUR SLIT LAMP INTO A LASER
DELIVERY SYSTEM
LASER INDIRECT
OPHTHALMOSCOPE:
THE CHOICE OF SPECIALISTS
The LaserLink slit lamp adapter is compatiThe LIO is designed for the ophthalmoloble with most diagnostic slit lamps.
The
gist’s comfort and safety as well as for pre-
Ultima 2000 SE adapts easily to your
cise laser delivery. The unique high-visibilfavorite slit lamp without compromising its
ity filter is always in place. The fixed filter
normal operation. Any exam lane can be
provides eye protection at all times and
utilized.
eliminates heavy, cumbersome mechanical shutters. As a result, the headset is
lightweight,
minimizing fatigue during
long procedures.
EASY, REPEATABLE ALIGNMENT
The LaserLink’s rugged adapter attaches to
the tonometer mount and assures precise
EXPANDING TREATMENT OPTIONS
focus of the laser and parfocality with the
The LIO is indicated for treating difficult
slit lamp.
cases such as infants or physically disabled
patients.
Excellent access to the far
periphery makes the LIO ideal for diabetic
retinopathy, retinal tears and retinal
detachment. Since no contact lens is nec-
YOU’RE IN CONTROL
essary, it is also suitable for patients with
The SureSpot™ telescope with sharprecent ocular surgery.
edged,
defocused spot allows a well-
defined spot on the retina with the assurThe Ultima 2000 SE addresses a broad range of clinical needs. Photocoagulation in the anterior or posteri-
ance of minimal power density to the
or chamber is accomplished with the LaserLink™ slit lamp adapter for existing Haag-Streit slit lamps or with
Lumenis’s complete line of dedicated slit lamp delivery systems offering both mechanical and electronic
micromanipulators for additional precision. Endophotocoagulation with Lumenis Acculite™ single-use
cornea or crystalline lens. The continuously
adjustable spot size selector is equipped
endoprobes is also possible. For treatment of the supine patient or infant, Lumenis’ proven Laser Indirect
with detents in the range of 50 to 500
Ophthalmoscope may be used. For each indication the delivery device of choice is available without com-
microns. Uniform burns and a well defined
promise.
aiming beam ensure a more rapid,
Each delivery system is designed for precise therapy with convenient operation and safety. For example, the fixed high-visibility physician filter on the LaserLink and the LIO provides dependable protection
for the ophthalmologist’s eyes and a clear view of the treatment site. Silent operation with no shutter
treatment.
safe
The remote control panel can be
The accessory module connects
The LaserLink provides clear
placed on the table on either side
the Ultima 2000 SE with mutiple
of the slit lamp, on the Ultima
delivery systems. It drives the
vision even in the far periphery.
The
accessory module, or on the oper-
selectable dual eye safety filters
unique dichroic laser mirror coaxially
ating room table instrument tray.
for the Acculite endoprobe and
reflects the laser beam while maintaining
The back-lit panel is easy to read,
provides illumination control for
clear illumination of the fundus.
even in a darkened treatment
the
room.
Illumination of the control panel
movement avoids patient anticipation of the treatment and consequent involuntary eye motion.
LIO.
Easy
simplify operation.
access
and
Ultima SE
Ultima® 2000 SE
F I V E WAY S T O R E D U C E T H E C O S T O F O W N E R S H I P
NO HIDDEN INSTALLATION COSTS
WITH QUIET AIR-COOLING
SAFETY SECOND TO NONE
The Ultima 2000 SE requires no special
state-of-the-art power supply ensure accura-
plumbing.
cy of exposure time and treatment power.
Quiet variable speed fans are
actuated only when cooling is required.
There is no special power requirement.
The dual-channel computer system and the
The Ultima 2000 SE has been approved by
safety agencies worldwide.
Simply plug the laser into any standard wall
NO LIMIT TO YOUR
TREATMENT OPTIONS
outlet.
The Ultima SE is flexible in meeting the
NO UNNECESSARY COSTS OF AN
ADDITIONAL LASER ROOM
The LaserLink slit lamp adapter can be used
with the diagnostic slit lamp you already
own. The laser console moves easily out of
the way,
allowing the ophthalmologist to
use the Ultima 2000 SE in even the smallest
treatment lane.
the Ultima 2000 SE to a variety of Lumenis
delivery systems to meet a specific clinical
requirement. With the accessory module
both the Laser Indirect Ophthalmoscope and
the Acculite endoprobe may be utilized.
There is no risk of obsolescence. The efficacy
of the argon laser has been proven in over
NO FINANCIAL RISKS WITH
A LUMENIS FIVE-YEAR
TUBE GUARANTEE
With Lumenis’ patented Power On Demand
technology, the Ultima 2000 SE offers virtually unlimited tube life by energizing the
laser only during each individual exposure.
Typical running time is less than one minute
per patient.
Specifications
Lumenis Inc.
2400 Condensa Street
Santa Clara, CA 95051 USA
Tel 408 764 3000
800 635 1313
Fax 408 764 3999
800 505 1133
Laser System
Lumenis (HOLLAND) BV
Amstelveen, The Netherlands
Tel + 31 20 347 50 60
Fax + 31 20 347 50 99
20 years of clinical use. As applications of the
argon laser continue to expand, utilization
of your laser will only increase.
Lumenis INNOVA® metal / ceramic Power On Demand™ plasma tube
Wavelength
Argon all lines: blue-green 488 nm - 528 nm
Argon green: 514nm, 528 nm
Power to the Cornea
1.5 watts of blue-green; 0.80 watts of green
Exposure Time
0.01, 0.02, 0.05, 0.07, 0.1, 0.15, 0.2, 0.3, 0.4, 0.5, 0.7, 1.0 seconds
Repeat Mode
Up to 3 Hz
Weight
65 lbs. (30 kg)
Dimensions
Console 8” W x 24 “ L x 18.5” H (20cm W x 61cm L x 47cm H)
100 - 120 VAC, 50/60 Hz, 15 or 20 amps
Forced Air
Aiming Beam
Red diode, adjustable intensity
Delivery System Options
Lumenis LaserLink™ slit lamp adapter attaches to these slit lamps:
Haag-Streit 900 BQ, Haag-Streit 900 BM, Haag-Streit 900 CN,
Topcon SL-3E, 5E, 7E, Marco V, Mentor SH-12, Nikon NS-1,
Nikon NS-3, Zeiss 20 SL, Zeiss 30 SL, Zeiss 125 SL, Zeiss SL-130
Lumenis Indirect Ophthalmoscope:
modified Keeler Fison headpiece at 1.2 lbs (545 gms);
spot size is 350 microns at focus
Lumenis (ITALY) Srl.
Rome, Italy
Tel + 39 06 90 75 230
Fax + 39 06 90 75 269
Acculite™ endoprobe accessory:
sterile; single-use straight or angled sterile 20-guage probes;
2-meter fiber
Lumenis (UK) Ltd.
London, UK
Tel + 44 20 8324 4200
Fax + 44 20 8324 4222
Ultima accessory module:
Laser Indirect Ophthalmoscope illumination power supply /
booster; dual eye physician filter drivers for Acculite endoprobe
or LaserLink Z slit lamp adapter.
Combination System
Compatible with the portable EPIC™
Q-switched Nd:YAG laser system
Electrical Certification
ETL listed to UL 544; CE Mark for medical devices
Quality Standards
ISO9001, EN46001
Lumenis (JAPAN) Co. Ltd.
Tokyo, Japan
Tel + 81 3 5789 8300
Fax + 81 3 5789 8310
Portable Argon Laser Photocoagulator
LUMENIS
CUSTOMER CARE
Worry-Free
Lumenis (HK) Ltd.
Kowloon, Hong Kong
Tel + 852 2174 2800
Fax + 852 2722 5151
Ultima 2000 SE
220 - 240 VAC, 50/60 Hz, 10 amps, single phase
Cooling
Lumenis (FRANCE) SARL
Suresnes, France
Tel + 33 1 41 44 99 99
Fax + 33 1 47 28 99 09
Lumenis Ltd.
Yokneam, Israel
Tel + 972 4 959 9000
Fax + 972 4 959 9050
®
Remote control 4” W x 6” L x 1.25” H (10cm W x 15cm L x 3cm H)
Power Requirements
Lumenis (GERMANY) GmbH
Dieburg, Germany
Tel + 49 6071 922 0
Fax + 49 6071 922 400
needs for both office and operating room
use. The available accessory module adapts
Argon Laser Photocoagulator
Service
and
Support
At Lumenis we understand the importance of delivering service and technical support of the highest quality.
When you buy a laser or light-based system from Lumenis, you make an investment in the world's most innovative medical technology in its category — backed by the most comprehensive service and support organization in
the industry. Customer satisfaction is paramount and the ultimate goal of our business.
Lumenis (HOLLAND) BV
Beijing Office
Beijing, China
Tel + 86 10 6510 2620
Fax + 86 10 6510 2621
LASER CLASS 4/IV
Argon Ion Laser: 476-529 nm, 3 W Max, CW
LASER CLASS 2/II
Diode Laser: 670 nm, 4 mW Max., CW
Lumenis (SWEDEN) AB
Kristianstad, Sweden
Tel + 46 44 21 21 26
Fax + 46 44 21 21 79
internet:
www.ophthalmic.lumenis.com
email: information@lumenis.com
VISIBLE LASER RADIATION
AVOID EYE OR SKIN EXPOSURE TO
DIRECT OR SCATTERED RADIATION
CLASS 4 LASER PRODUCT per EN 60825-1/1994
CLASS IV LASER PRODUCT per 21 CFR 1040
93/42/EEC
0086
EN
4
6
0
0
1
REGISTERED
Lumenis and its logo, and INNOVA, Ultima, Acculite,
LaserLink, SureSpot, and Power On Demand are trademarks or registered trademarks of the Lumenis group of
companies. Copyright © 2002, the Lumenis group of companies. Product specifications are subject to change without
notice. Caution: U.S. law restricts this device to sale by or on
the order of a physician. All rights reserved.
Printed in USA. 3/0210M
PBE000006
Formerly
Coherent Medical Group
and ESC Sharplan