WALL MOUNTED SPLIT SYSTEMS G SERIES

Transcription

WALL MOUNTED SPLIT SYSTEMS G SERIES
WALL MOUNTED
SPLIT SYSTEMS
G SERIES
F
E
A T
U
R
E
S
AIR PURIFYING SYSTEM
• Negative Ion Generator (Standard)
The Ion Generator releases negative ion shower to create a refreshing
and clean environment as if you are fallen into the world of nature.
• AWM-G Series Offers Various Indoor Air Quality Features
Improved with NanoTechnology
That Redefines 21st Century Living Environment
- Effectively Inactivate & Eliminate Various Harmful Airborne Elements
99.9% bacteria free, no more worries
Acson is focused on developing new and exciting products
to improve everyday living environment of the 21st century.
The all-new NanoShield combines powerful sterilizing and
deodorizing effect of NanoSilver and nano-Photocatalyst.
Silver is used from the days of
Hippocrates (Father of Medicine)
as a healing agent and its use
has been expanded into antibacterial applications ever
since. Modern nanotechnology
provides through full - infusion
onto the filters and larger coated
surface area, with this sterilization,
deodorizing power is 150 times stronger whereas
filtration effectiveness is improved 20 times.
NanoPhotocatalyst deVOCs & deodorization
(150 times stronger than high
performance activated carbon)
NanoSilver -bacteria & germs
elimination
Pre Filter
• Triple Action
N eutralizes Harm ful G as es
High-energy oxygen plasma combines easily
with most harmful gases to neutralize, and
render them harmless to human beings. For
example, NTP Air Sterilizer can lower the
concentration of carbon monoxide (CO) that
causes fatigue, headaches, etc. When oxygen
plasmas neutralize CO, carbon dioxide is
produced. This process is irreversible. Thus
effectively reducing the amount of CO
molecules in the indoor environment.
Oxygen Plasma
R em oves Dus t
Inhibits G row th Of Harm ful
G erm s & M icrobes
Nascent oxygen plasmas combine with other
oxygen molecules to form ions (charged
particles), including small ions, mean ions,
and large ions. These attract dust particles
easily and tend to sink to the ground faster
than normal dust particles. This helps to
reduce health-problems caused by dusty
environment.
NTP Air Sterilizer disrupts the basic biological
process of microbes. Oxygen plasmas simply
combines with the cell structure to negatively
affect the growth and activity of certain
harmful microbes and germs. This will reduce
the amount of harmful entities in the air,
easily creating healthier air.
Oxygen Plasma
Micro-Organism
Oxygen Plasma
Osmongens Organically Odours (Gases)
+
+
+
Oxygen Molecules
Small Ions
Mean Ions
Large Ions
Non-Harmful Gas
Irreversible Process
Capture Dust And Particles
Inactive/non-harmful microbes
• O2 Therapy (Premium Series)
O2 Pump
A specially designed oxygen enrichment module, will
allow O2 to penetrate through its membranes at faster
rate compared to N2, which result in increase of O2 in
air. The O 2 enriched air provides a fresh living
environment in your house or office.
* Please refer to your local agent/dealer for product with this specification.
– pump the O2
enriched air to indoor
Oxygen
Enrichment
Module
Available for A(5)WM10 & 15G only.
Normal air
Oxygen
Enriched Air
Cross-section of module
Frame
O2:
O2: 21%
Oxygen
Enriched Air
Oxygen
Enrichment
Membrane
N2
N2
Normal
air
N2: 70%
N2
Frame
Oxygen
Enrichment
Membrane
O2:
O2: 30%
N2: 79%
N2
O2
N2
O2
N2
N2
N2
N2
Oxygen Enrichment
Membrane
Oxygen Enrichment Module
N2
O2
N2
N2
N2
N2
O2
O2
N2
Vacuum
Pump
• New Outdoor Condensing Unit
The new condensing unit (C series) is using the aluminium
slit fin, which can greatly increase the heat transfer efficiency
and boost up the unit capacity effectively. The valve cover
design enables the condensed water to be carried into base
pan instead of dripping onto the floor.
> Aluminium Slit Fin
• With R410A Refrigerant
• Not harmful to the Earth's ozone layer with Ozone Depletion Potential = 0.
• Higher volumetric capacity and increased EER & COP
compared to R22 and R407C.
H
C
H
F
C
F
F
F
H
F
C
F
F
50% R125
50% R32
(R410A)
• Network Interface Module - Telephone Control (NIM-Tele)
By just making up a call, user can control the operation of the air conditioner remotely at anytime and
anywhere. This innovative technology not only provides on/off control but also operating mode control,
temperature control and status monitoring availability. The password protection function ensures more
safety operation to the system.
NIM-TELE
MODULE
New Aesthetically
Outlook
A smooth front panel makes
the cleaning process much
easier for the user. These units
blended easily into any
interior decoration and
design. The centrally located
LED light makes it easier for
user to check the operating
conditions.
3-Fold Heat Exchanger
Double Louver
The compact design of this
3-fold structure provides
a large surface
area for better &
efficient heat
exchange.
This new louver design
together with its automatic air
swing function fully
optimizes the room comfort
by distributing the air evenly
to every corner of the room.
• Easy Serviceability
Wall Mounted G series comes with a new design
of air discharge housing whereby the fan blower
can be easily accessed by just loosing up two
screws on the unit. This new feature provides a
flexible, faster and easier way to clean up the fan
blower and ionizer.
• High Performance With COP >3.5
Energy
Air Conditioner
Manufacturer
Outside Unit
Inside Unit
A5LC10CR
A5WM10GR
More efficient
A
A
B
C
D
E
F
G
Less efficient
Annual Energy Consumption,
kWh in cooling mode
433
Cooling output
2.8
(Actual consumption will depend
on how the appliance is used
and climate)
kW
3.2
Energy Efficiency Ratio
Full load (the higher the better)
Type
Cooling only
Cooling + Heating
• Enhance Skew Fan Design
The unique skew fan design provides an improved
sound quality while its larger diameter creates
better air flow to the operating environment.
Air cooled
Water cooled
Heat output
kW
Heating Performance
A: higher
G: lower
Noise
(dB(A) re 1 pW)
Further information is contained
in product brochures
Norm EN 814
Air conditioner
Energy Label Directive YY/XX/EC
2.8
ABCDEFG
According to criteria
of European Union
regulation. The
efficient Acson new air
conditioner, model
A5WM07GR and
A5WM10GR has
achieved the highest
energy rating of A, in a
scale of A to G, based
on the Energy Rating
Efficiency Ratio (EER).
• EASY-To-Use LCD Remote Controller
Ionizer
Just press the ionizer button and the air-conditioner will generates negative ion, which will refresh the
indoor air effectively.
Temperature ˚C
Turbo Mode
TURBO function is available in COOL, HEAT and DRY modes only.
Once turbo mode is activated, the air-conditioner will run into full
power with indoor fan running at HIGH speed for 20 minutes. This
enables the required set temperature to be achieved in a short time. If
TURBO and SLEEP are activated at the same time, the SLEEP mode
timer will be reset, it will resume after TURBO function is cleared.
20min
30min
TURBO MODE
CONVENTIONAL
Personalized Setting
It allows user to pre-set and store 2 groups of personal settings
(included timer setting) in the handset. This personalized settings
can be overwrite from time to time based on user requirements.
Temperature Setting
“On/Off” Button
Personalized Setting
On Timer Setting
OFF Timer Setting
Ionizer
Fan Speed Selection
Sleep Mode Setting
Operation Mode
Automatic Air Swing
Turbo Mode Setting
Cooling
Setting of Sleep mode will gradually increase
or decrease the setting temperature to provide
a comfortable surrounding for sleeping. It is
also acts as an energy saving mode.
Auto Random Restart
2
Hours
+1ºc
Temperature
Sleep Mode Auto Control
Temperature
Sleep Set On
0
1/2
1
-1ºc
-2ºc
+0.5˚c
+0.5˚c
-3ºc
Heating
0
1/2
1
Sleep Set On
HEATING
When there is power failure occurred during operation, the unit
will automatically restart as the last setting condition once the
power is resumed. Option is provided to cancel this feature.
Hours
2
COOLING
Auto Restart System
Power Failure
Operation
Power Returns
Stop
Restart
2
E PROM
Setting stored before power failure.
S P E C I F I C AT I O N S
HEAT PUMP
INDOOR UNIT
OUTDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
POWER SOURCE
COOLING
HEATING
COOLING
RUNNING CURRENT
HEATING
INDOOR UNIT
COOLING ONLY
OUTDOOR UNIT
INPUT POWER
NOMINAL COOLING CAPACITY
INDOOR UNIT
POWER SOURCE
INPUT POWER
RUNNING CURRENT
FAN TYPE
AIR FLOW
SOUND LEVEL - H / M / L
HEIGHT
DIMENSION
WIDTH
DEPTH
WEIGHT
W
Btu/h
W
Btu/h
V/Ph/Hz
W
W
A
A
W
Btu/h
V/Ph/Hz
W
A
cfm / L/s
dB(A)
mm/in
mm/in
mm/in
kg
AIR FILTRATION
COMPRESSOR TYPE
REFRIGERANT TYPE
REFRIGERANT CONTROL
SOUND PRESSURE LEVEL
HEIGHT
DIMENSION
WIDTH
DEPTH
WEIGHT (kg)
TYPE
LIQUID
PIPE SIZE
GAS
dB(A)
mm/in
mm/in
mm/in
PIPE
OUTDOOR UNIT
AIR TREATMENT DEVICES
mm/in
mm/in
[R22 Models]
AWM09GR
ALC09CR
2640
9000
2640
9000
AWM10GR
ALC10CR
2780
9500
2780
9500
AWM15GR
AWM20GR
AWM20GR
ALC15CR
ALC18CR
ALC20CR
3520
5275
5570
12000
18000
19000
3520
5420
5715
12000
18500
19500
220 -240 / 1 / 50
910
835
1760
1780
1100
750
755
980
1810
1830
4.0
3.8
5.0
7.6
8.0
3.4
3.4
4.5
7.5
8.1
AWM09G
AWM10G
AWM15G
AWM20G
AWM20G
ALC09C
ALC10C
ALC15C
ALC18C
ALC20C
2640
2780
3,520
5275
5570
9000
9500
12,000
18000
19000
220 -240 / 1 / 50
880
836
1,100
1770
1790
3.9
3.7
4.9
7.9
8.3
ANTI-FUNGUS SKEW FAN
275 / 130
300 / 142
345 / 163
510 / 241
40 / 35 / 29
39 / 34 / 28
42 / 36 / 29
44 / 40 / 36
260 / 10.2
260 / 10.2
306 / 12.0
799 / 31.4
899 / 35.4
1062 / 41.8
198 / 7.8
198 / 7.8
222 / 8.7
10
12
15
NANOSILVER-COATED ANTI-BACTERIAL SARANET FILTER
NANOPHOTOCATALYST-COATED DEODORIZING SARANET FILTER
NEGATIVE ION GENERATOR
NON-THERMAL PLASMA (NTP) AIR STERILIZER
ROTARY HERMETIC
R22
CAPILLARY TUBE
45
46
49
50
50
495/19.5
540/21.3
651 / 25.6
600/23.6
700/27.6
855 / 33.7
245/9.7
250/9.8
328 / 12.1
28
32
57
FLARE VALVE
6.35 / 1/4
9.52 / 3/8
12.7 / 1/2
15.88 / 5/8
AWM25GR
ALC25CR
6890
23500
7035
24000
2600
2540
12.6
12.5
AWM25G
ALC25C
6890
23500
2620
12.8
650 / 307
49 / 44 / 42
52
753 / 29.6
855 / 33.7
328 / 12.1
58
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151: 1994(E)
3) NOMINAL COOLING CAPACITY IS BASED ON THE CONDITIONS BELOW :
COOLING : 27°C DB / 19°C WB INDOOR AND 35°C DB OUTDOOR
4) ALLOWABLE OPERATING RANGE:
COOLING : 19.4°C DB / 13.9°C WB INDOOR AND 19.4°C DB OUTDOOR TO 26.7°C DB / 19.4°C WB INDOOR AND 46.1°C DB OUTDOOR
5) ALC18CR AVAILABLE FROM APRIL '06 ONWARDS
SPECIFICATIONS [R22-60HZ]
HEAT PUMP
INDOOR UNIT
OUTDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
POWER SOURCE
INPUT POWER
RUNNING CURRENT
COOLING ONLY
COOLING
HEATING
COOLING
HEATING
INDOOR UNIT
OUTDOOR UNIT
NOMINAL COOLING CAPACITY
POWER SOURCE
INPUT POWER
RUNNING CURRENT
FAN TYPE
AIR FLOW
SOUND LEVEL - H / M / L
HEIGHT
DIMENSION
WIDTH
DEPTH
WEIGHT
INDOOR UNIT
W
Btu/h
W
Btu/h
V/Ph/Hz
W
W
A
A
W
Btu/h
V/Ph/Hz
W
A
cfm / L/s
dB(A)
mm/in
mm/in
mm/in
kg
AWM10GR
ALC10BR
2700
9200
2700
9500
AWM15GR
ALC15BR
3370
11500
3520
12000
827
747
3.8
3.4
AWM10G
ALC10B
2700
9200
1221
1051
5.4
4.6
AWM15G
ALC15B
3370
11500
827
3.8
1221
5.4
300 / 142
39 / 34 / 28
PIPE
OUTDOOR UNIT
AIR TREATMENT DEVICES
dB(A)
mm/in
mm/in
mm/in
kg
mm/in
mm/in
AWM25GR
ALC25BR
6450
22000
6890
23500
1905
1773
8.4
7.9
AWM20G
ALC20B
5570
19000
2415
2285
10.7
10.1
AWM25G
ALC25B
6450
22000
1905
8.4
2415
10.7
208 - 230 / 1 / 60
AIR FILTRATION
COMPRESSOR TYPE
REFRIGERANT TYPE
REFRIGERANT CONTROL
SOUND PRESSURE LEVEL
HEIGHT
DIMENSION
WIDTH
DEPTH
WEIGHT
TYPE
LIQUID
PIPE SIZE
GAS
208 - 230 / 1 / 60
AWM20GR
ALC20BR
5570
19000
5570
19000
48
31
9.52 / 3/8
260 / 10.2
899 / 35.4
198 / 7.8
12
ANTI-FUNGUS SKEW FAN
345 / 163
510 / 241
42 / 36 / 29
44 / 40 /36
306 / 12.0
1062 / 41.8
222 / 8.7
15
NANOSILVER-COATED ANTI-BACTERIAL SARANET FILTER
NANOPHOTOCATALYST-COATED DEODORIZING SARANET FILTER
NEGATIVE ION GENERATOR
NON-THERMAL PLASMA (NTP) AIR STERILIZER
ROTARY HERMETIC
R22
CAPILLARY TUBE
49
52
494 / 19.4
646 / 25.4
740 / 29.1
840 / 33.1
270 / 10.6
330 / 13.0
34
57
FLARE VALVE
6.35 / 1/4
12.7 / 1/2
15.88 / 5/8
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) NOMINAL COOLING CAPACITY IS BASED ON THE CONDITIONS BELOW :
COOLING : 27°C DB / 19°C WB INDOOR AND 35°C DB OUTDOOR
3) ALLOWABLE OPERATING RANGE:
COOLING : 19.4°C DB / 13.9°C WB INDOOR AND 19.4°C DB OUTDOOR TO 26.7°C DB / 19.4°C WB INDOOR AND 46.1°C DB OUTDOOR
650 / 307
49 / 44 / 42
53
58
9.52 / 3/8
SPEC IFIC A T IO N S
HEAT PUMP
I NDOOR UNI T
OUTDOOR UNI T
NOMI NAL COOLI NG CAPACI TY
NOMI NAL HEATI NG CAPACI TY
POWER SOURCE
I NPUT POWER
RUNNI NG CURRENT
COOLI NG ONLY
COOLI NG
HEATI NG
COOLI NG
HEATI NG
I NDOOR UNI T
POWER SOURCE
I NPUT POWER
RUNNI NG CURRENT
FAN TYPE
AI R FLOW
SOUND LEVEL - H / M / L
HEI GHT
DI MENSI ON
WI DTH
DEPTH
WEI GHT
I NDOOR UNI T
W
Btu/ h
W
Btu/ h
V/ Ph/ Hz
W
W
A
A
A5WM09GR
A5LC10CR
2640
9000
2640
9000
680
550
3.1
2.6
A5WM07G
A5LC07C
2200
7500
OUTDOOR UNI T
NOMI NAL COOLI NG CAPACI TY
[R410A]
A5WM07GR
A5LC07CR
2200
7500
2200
7500
W
Btu/ h
V/ Ph/ Hz
W
A
620
2.9
cfm / L/ s
dB(A)
mm/ in
mm/ in
mm/ in
kg
275 / 130
40 / 35 / 29
260 / 10.2
799 / 31.5
198 / 7.8
10
AI R FI LTRATI ON
COMPRESSOR TYPE
PROTECTI ON DEVI CE
REFRI GERANT TYPE
SOUND PRESSURE LEVEL
HEI GHT
DI MENSI ON
WI DTH
DEPTH
WEI GHT (kg)
PI PE
OUTDOOR UNI T
AI R TREATMENT DEVI CES
dB(A)
mm/ in
mm/ in
mm/ in
A5WM15GR
A5LC15CR
3520
12000
3520
12000
220 -240 / 1 / 50
865
865
1200
745
745
1080
3.9
3.9
5.4
3.4
3.4
4.9
A5WM09G
A5WM10G
A5WM15G
A5LC10C
A5LC10C
A5LC15C
2640
2780
3520
9000
9500
12000
220 -240 / 1 / 50
865
865
1230
3.9
3.9
5.5
ANTI -FUNGUS SKEW FAN
300 / 142
345 / 163
39 / 34 / 28
42 / 36 / 29
260 / 10.2
899 / 35.4
198 / 7.8
12
NANOSI LVER-COATED ANTI -BACTERI AL SARANET FI LTER
NANOPHOTOCATALYST-COATED DEODORI ZI NG SARANET FI LTER
NEGATI VE I ON GENERATOR
NON-THERMAL PLASMA (NTP) AI R STERI LI ZER
ROTARY HERMETI C
EXTERNAL OVERLOAD PROTECTOR
44
495 / 19.5
600 / 23.6
245 / 9.7
26
33
PI PE SI ZE
LI QUI D
GAS
HEAT PUMP
NOMI NAL HEATI NG CAPACI TY
POWER SOURCE
I NPUT POWER
RUNNI NG CURRENT
COOLI NG ONLY
COOLI NG
HEATI NG
COOLI NG
HEATI NG
I NDOOR UNI T
OUTDOOR UNI T
NOMI NAL COOLI NG CAPACI TY
POWER SOURCE
I NPUT POWER
RUNNI NG CURRENT
FAN TYPE
AI R FLOW
SOUND LEVEL - H / M / L
HEI GHT
DI MENSI ON
WI DTH
DEPTH
WEI GHT
35
FLARE VALVE
9.52 / 3/ 8
AWM07GR
A4LC07BR
2230
7600
2170
7400
W
Btu/ h
W
Btu/ h
V/ Ph/ Hz
W
W
A
A
795
750
3.4
3.2
AWM07G
A4LC07B
2170
7400
W
Btu/ h
V/ Ph/ Hz
W
A
855
3.6
cfm / L/ s
dB(A)
mm/ in
mm/ in
mm/ in
kg
275 / 130
40 / 35 / 29
260 / 10.2
799 / 31.4
198 / 7.8
10
dB(A)
mm/ in
mm/ in
mm/ in
47
AI R TREATMENT DEVI CES
PI PE
28
TYPE
PI PE SI ZE
LI QUI D
GAS
A5LC25CR
6155
21000
6450
22000
1640
1550
6.8
6.6
A5WM20G
1900
1850
8.3
8.3
A5WM25G
A5LC20C
5275
18000
A5LC25C
6155
21000
1630
6.8
1890
8.3
510 / 241
44 / 40 / 36
650 / 307
49 / 44 / 42
306 / 12.0
1062 / 41.8
222 / 8.7
15
BUI LT-I N OVERLOAD PROTECTOR
53
753 / 29.6
855 / 33.7
328 / 12.1
58
mm/ in
mm/ in
12.7 / 1/ 2
15.88 / 5/ 8
4) ALLOWABLE OPERATI NG RANGE:
COOLI NG : 19.4°C DB / 13.9°C WB I NDOOR AND 19.4°C DB OUTDOOR
TO 26.7°C DB / 19.4°C WB I NDOOR AND 46.1°C DB OUTDOOR
[R407C]
AI R FI LTRATI ON
COMPRESSOR TYPE
PROTECTI ON DEVI CE
REFRI GERANT TYPE
REFRI GERANT CONTROL
SOUND PRESSURE LEVEL
HEI GHT
DI MENSI ON
WI DTH
DEPTH
WEI GHT (kg)
A5WM25GR
A5LC20CR
5275
18000
5275
18000
6.35 / 1/ 4
mm/ in
mm/ in
I NDOOR UNI T
OUTDOOR UNI T
NOMI NAL COOLI NG CAPACI TY
A5WM20GR
52
651 / 25.6
855 / 33.7
328 / 12.1
57
540 / 21.3
700 / 27.6
250 / 9.8
TYPE
SPEC IFIC A T IO N S
I NDOOR UNI T
R410A
49
46
1) ALL SPECI FI CATI ONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WI THOUT PRI OR NOTI CE.
2) ALL UNI TS ARE BEI NG TESTED AND COMPLY TO I SO 5151: 1994(E)
3) NOMI NAL COOLI NG CAPACI TY I S BASED ON THE CONDI TI ONS BELOW :
COOLI NG : 27°C DB / 19°C WB I NDOOR AND 35°C DB OUTDOOR
OUTDOOR UNI T
A5WM10GR
A5LC10CR
2780
9500
2780
9500
AWM15GR
AWM20GR
AWM25GR
A4LC15BR
A4LC20BR
A4LC25BR
3225
5130
6010
11000
17500
20500
3665
5570
7035
12500
19000
24000
220 -240 / 1 / 50
975
2185
2775
1440
825
1290
2280
2750
4.3
6.6
10.3
13.5
3.6
6.1
10.9
13.4
AWM10G
AWM15G
AWM20G
AWM25G
A4LC10B
A4LC15B
A4LC20B
A4LC25B
2640
3225
5365
6155
9000
11000
18300
21000
220 -240 / 1 / 50
1440
2295
2860
975
4.3
6.6
10.7
13.4
ANTI -FUNGUS SKEW FAN
300 / 142
345 / 163
510 / 241
650 / 307
39 / 34 / 28
42 / 36 / 29
44 / 40 / 36
49 / 44 / 42
260 / 10.2
306 / 12.0
899 / 35.4
1062 / 41.8
198 / 7.8
222 / 8.7
12
15
NANOSI LVER-COATED ANTI -BACTERI AL SARANET FI LTER
NANOPHOTOCATALYST-COATED DEODORI ZI NG SARANET FI LTER
NEGATI VE I ON GENERATOR
NON-THERMAL PLASMA (NTP) AI R STERI LI ZER
ROTARY HERMETI C
BUI LT-I N OVERLOAD PROTECTOR
EXTERNAL OVERLOAD PROTECTOR
R407C
CAPI LLARY TUBE
52
53
48
49
646 / 25.4
494 / 19.4
840 / 33.1
740 / 29.1
330 / 13.0
270 / 10.6
57
58
31
34
FLARE VALVE
9.52 / 3/ 8
6.35 / 1/ 4
15.88 / 5/ 8
9.52 / 3/ 8
12.7 / 1/ 2
1) ALL SPECI FI CATI ONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WI THOUT PRI OR NOTI CE.
2) ALL UNI TS ARE BEI NG TESTED AND COMPLY TO I SO 5151: 1994(E)
3) NOMI NAL COOLI NG CAPACI TY I S BASED ON THE CONDI TI ONS BELOW :
COOLI NG : 27°C DB / 19°C WB I NDOOR AND 35°C DB OUTDOOR
AP - AWM - G - 06A
AWM10GR
A4LC10BR
2640
9000
2785
9500
4) ALLOWABLE OPERATI NG RANGE:
COOLI NG : 19.4°C DB / 13.9°C WB I NDOOR AND 19.4°C DB OUTDOOR
TO 26.7°C DB / 19.4°C WB I NDOOR AND 46.1°C DB OUTDOOR
www.acson-international.com