WALL MOUNTED SPLIT SYSTEMS G SERIES
Transcription
WALL MOUNTED SPLIT SYSTEMS G SERIES
WALL MOUNTED SPLIT SYSTEMS G SERIES F E A T U R E S AIR PURIFYING SYSTEM • Negative Ion Generator (Standard) The Ion Generator releases negative ion shower to create a refreshing and clean environment as if you are fallen into the world of nature. • AWM-G Series Offers Various Indoor Air Quality Features Improved with NanoTechnology That Redefines 21st Century Living Environment - Effectively Inactivate & Eliminate Various Harmful Airborne Elements 99.9% bacteria free, no more worries Acson is focused on developing new and exciting products to improve everyday living environment of the 21st century. The all-new NanoShield combines powerful sterilizing and deodorizing effect of NanoSilver and nano-Photocatalyst. Silver is used from the days of Hippocrates (Father of Medicine) as a healing agent and its use has been expanded into antibacterial applications ever since. Modern nanotechnology provides through full - infusion onto the filters and larger coated surface area, with this sterilization, deodorizing power is 150 times stronger whereas filtration effectiveness is improved 20 times. NanoPhotocatalyst deVOCs & deodorization (150 times stronger than high performance activated carbon) NanoSilver -bacteria & germs elimination Pre Filter • Triple Action N eutralizes Harm ful G as es High-energy oxygen plasma combines easily with most harmful gases to neutralize, and render them harmless to human beings. For example, NTP Air Sterilizer can lower the concentration of carbon monoxide (CO) that causes fatigue, headaches, etc. When oxygen plasmas neutralize CO, carbon dioxide is produced. This process is irreversible. Thus effectively reducing the amount of CO molecules in the indoor environment. Oxygen Plasma R em oves Dus t Inhibits G row th Of Harm ful G erm s & M icrobes Nascent oxygen plasmas combine with other oxygen molecules to form ions (charged particles), including small ions, mean ions, and large ions. These attract dust particles easily and tend to sink to the ground faster than normal dust particles. This helps to reduce health-problems caused by dusty environment. NTP Air Sterilizer disrupts the basic biological process of microbes. Oxygen plasmas simply combines with the cell structure to negatively affect the growth and activity of certain harmful microbes and germs. This will reduce the amount of harmful entities in the air, easily creating healthier air. Oxygen Plasma Micro-Organism Oxygen Plasma Osmongens Organically Odours (Gases) + + + Oxygen Molecules Small Ions Mean Ions Large Ions Non-Harmful Gas Irreversible Process Capture Dust And Particles Inactive/non-harmful microbes • O2 Therapy (Premium Series) O2 Pump A specially designed oxygen enrichment module, will allow O2 to penetrate through its membranes at faster rate compared to N2, which result in increase of O2 in air. The O 2 enriched air provides a fresh living environment in your house or office. * Please refer to your local agent/dealer for product with this specification. – pump the O2 enriched air to indoor Oxygen Enrichment Module Available for A(5)WM10 & 15G only. Normal air Oxygen Enriched Air Cross-section of module Frame O2: O2: 21% Oxygen Enriched Air Oxygen Enrichment Membrane N2 N2 Normal air N2: 70% N2 Frame Oxygen Enrichment Membrane O2: O2: 30% N2: 79% N2 O2 N2 O2 N2 N2 N2 N2 Oxygen Enrichment Membrane Oxygen Enrichment Module N2 O2 N2 N2 N2 N2 O2 O2 N2 Vacuum Pump • New Outdoor Condensing Unit The new condensing unit (C series) is using the aluminium slit fin, which can greatly increase the heat transfer efficiency and boost up the unit capacity effectively. The valve cover design enables the condensed water to be carried into base pan instead of dripping onto the floor. > Aluminium Slit Fin • With R410A Refrigerant • Not harmful to the Earth's ozone layer with Ozone Depletion Potential = 0. • Higher volumetric capacity and increased EER & COP compared to R22 and R407C. H C H F C F F F H F C F F 50% R125 50% R32 (R410A) • Network Interface Module - Telephone Control (NIM-Tele) By just making up a call, user can control the operation of the air conditioner remotely at anytime and anywhere. This innovative technology not only provides on/off control but also operating mode control, temperature control and status monitoring availability. The password protection function ensures more safety operation to the system. NIM-TELE MODULE New Aesthetically Outlook A smooth front panel makes the cleaning process much easier for the user. These units blended easily into any interior decoration and design. The centrally located LED light makes it easier for user to check the operating conditions. 3-Fold Heat Exchanger Double Louver The compact design of this 3-fold structure provides a large surface area for better & efficient heat exchange. This new louver design together with its automatic air swing function fully optimizes the room comfort by distributing the air evenly to every corner of the room. • Easy Serviceability Wall Mounted G series comes with a new design of air discharge housing whereby the fan blower can be easily accessed by just loosing up two screws on the unit. This new feature provides a flexible, faster and easier way to clean up the fan blower and ionizer. • High Performance With COP >3.5 Energy Air Conditioner Manufacturer Outside Unit Inside Unit A5LC10CR A5WM10GR More efficient A A B C D E F G Less efficient Annual Energy Consumption, kWh in cooling mode 433 Cooling output 2.8 (Actual consumption will depend on how the appliance is used and climate) kW 3.2 Energy Efficiency Ratio Full load (the higher the better) Type Cooling only Cooling + Heating • Enhance Skew Fan Design The unique skew fan design provides an improved sound quality while its larger diameter creates better air flow to the operating environment. Air cooled Water cooled Heat output kW Heating Performance A: higher G: lower Noise (dB(A) re 1 pW) Further information is contained in product brochures Norm EN 814 Air conditioner Energy Label Directive YY/XX/EC 2.8 ABCDEFG According to criteria of European Union regulation. The efficient Acson new air conditioner, model A5WM07GR and A5WM10GR has achieved the highest energy rating of A, in a scale of A to G, based on the Energy Rating Efficiency Ratio (EER). • EASY-To-Use LCD Remote Controller Ionizer Just press the ionizer button and the air-conditioner will generates negative ion, which will refresh the indoor air effectively. Temperature ˚C Turbo Mode TURBO function is available in COOL, HEAT and DRY modes only. Once turbo mode is activated, the air-conditioner will run into full power with indoor fan running at HIGH speed for 20 minutes. This enables the required set temperature to be achieved in a short time. If TURBO and SLEEP are activated at the same time, the SLEEP mode timer will be reset, it will resume after TURBO function is cleared. 20min 30min TURBO MODE CONVENTIONAL Personalized Setting It allows user to pre-set and store 2 groups of personal settings (included timer setting) in the handset. This personalized settings can be overwrite from time to time based on user requirements. Temperature Setting “On/Off” Button Personalized Setting On Timer Setting OFF Timer Setting Ionizer Fan Speed Selection Sleep Mode Setting Operation Mode Automatic Air Swing Turbo Mode Setting Cooling Setting of Sleep mode will gradually increase or decrease the setting temperature to provide a comfortable surrounding for sleeping. It is also acts as an energy saving mode. Auto Random Restart 2 Hours +1ºc Temperature Sleep Mode Auto Control Temperature Sleep Set On 0 1/2 1 -1ºc -2ºc +0.5˚c +0.5˚c -3ºc Heating 0 1/2 1 Sleep Set On HEATING When there is power failure occurred during operation, the unit will automatically restart as the last setting condition once the power is resumed. Option is provided to cancel this feature. Hours 2 COOLING Auto Restart System Power Failure Operation Power Returns Stop Restart 2 E PROM Setting stored before power failure. S P E C I F I C AT I O N S HEAT PUMP INDOOR UNIT OUTDOOR UNIT NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY POWER SOURCE COOLING HEATING COOLING RUNNING CURRENT HEATING INDOOR UNIT COOLING ONLY OUTDOOR UNIT INPUT POWER NOMINAL COOLING CAPACITY INDOOR UNIT POWER SOURCE INPUT POWER RUNNING CURRENT FAN TYPE AIR FLOW SOUND LEVEL - H / M / L HEIGHT DIMENSION WIDTH DEPTH WEIGHT W Btu/h W Btu/h V/Ph/Hz W W A A W Btu/h V/Ph/Hz W A cfm / L/s dB(A) mm/in mm/in mm/in kg AIR FILTRATION COMPRESSOR TYPE REFRIGERANT TYPE REFRIGERANT CONTROL SOUND PRESSURE LEVEL HEIGHT DIMENSION WIDTH DEPTH WEIGHT (kg) TYPE LIQUID PIPE SIZE GAS dB(A) mm/in mm/in mm/in PIPE OUTDOOR UNIT AIR TREATMENT DEVICES mm/in mm/in [R22 Models] AWM09GR ALC09CR 2640 9000 2640 9000 AWM10GR ALC10CR 2780 9500 2780 9500 AWM15GR AWM20GR AWM20GR ALC15CR ALC18CR ALC20CR 3520 5275 5570 12000 18000 19000 3520 5420 5715 12000 18500 19500 220 -240 / 1 / 50 910 835 1760 1780 1100 750 755 980 1810 1830 4.0 3.8 5.0 7.6 8.0 3.4 3.4 4.5 7.5 8.1 AWM09G AWM10G AWM15G AWM20G AWM20G ALC09C ALC10C ALC15C ALC18C ALC20C 2640 2780 3,520 5275 5570 9000 9500 12,000 18000 19000 220 -240 / 1 / 50 880 836 1,100 1770 1790 3.9 3.7 4.9 7.9 8.3 ANTI-FUNGUS SKEW FAN 275 / 130 300 / 142 345 / 163 510 / 241 40 / 35 / 29 39 / 34 / 28 42 / 36 / 29 44 / 40 / 36 260 / 10.2 260 / 10.2 306 / 12.0 799 / 31.4 899 / 35.4 1062 / 41.8 198 / 7.8 198 / 7.8 222 / 8.7 10 12 15 NANOSILVER-COATED ANTI-BACTERIAL SARANET FILTER NANOPHOTOCATALYST-COATED DEODORIZING SARANET FILTER NEGATIVE ION GENERATOR NON-THERMAL PLASMA (NTP) AIR STERILIZER ROTARY HERMETIC R22 CAPILLARY TUBE 45 46 49 50 50 495/19.5 540/21.3 651 / 25.6 600/23.6 700/27.6 855 / 33.7 245/9.7 250/9.8 328 / 12.1 28 32 57 FLARE VALVE 6.35 / 1/4 9.52 / 3/8 12.7 / 1/2 15.88 / 5/8 AWM25GR ALC25CR 6890 23500 7035 24000 2600 2540 12.6 12.5 AWM25G ALC25C 6890 23500 2620 12.8 650 / 307 49 / 44 / 42 52 753 / 29.6 855 / 33.7 328 / 12.1 58 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151: 1994(E) 3) NOMINAL COOLING CAPACITY IS BASED ON THE CONDITIONS BELOW : COOLING : 27°C DB / 19°C WB INDOOR AND 35°C DB OUTDOOR 4) ALLOWABLE OPERATING RANGE: COOLING : 19.4°C DB / 13.9°C WB INDOOR AND 19.4°C DB OUTDOOR TO 26.7°C DB / 19.4°C WB INDOOR AND 46.1°C DB OUTDOOR 5) ALC18CR AVAILABLE FROM APRIL '06 ONWARDS SPECIFICATIONS [R22-60HZ] HEAT PUMP INDOOR UNIT OUTDOOR UNIT NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY POWER SOURCE INPUT POWER RUNNING CURRENT COOLING ONLY COOLING HEATING COOLING HEATING INDOOR UNIT OUTDOOR UNIT NOMINAL COOLING CAPACITY POWER SOURCE INPUT POWER RUNNING CURRENT FAN TYPE AIR FLOW SOUND LEVEL - H / M / L HEIGHT DIMENSION WIDTH DEPTH WEIGHT INDOOR UNIT W Btu/h W Btu/h V/Ph/Hz W W A A W Btu/h V/Ph/Hz W A cfm / L/s dB(A) mm/in mm/in mm/in kg AWM10GR ALC10BR 2700 9200 2700 9500 AWM15GR ALC15BR 3370 11500 3520 12000 827 747 3.8 3.4 AWM10G ALC10B 2700 9200 1221 1051 5.4 4.6 AWM15G ALC15B 3370 11500 827 3.8 1221 5.4 300 / 142 39 / 34 / 28 PIPE OUTDOOR UNIT AIR TREATMENT DEVICES dB(A) mm/in mm/in mm/in kg mm/in mm/in AWM25GR ALC25BR 6450 22000 6890 23500 1905 1773 8.4 7.9 AWM20G ALC20B 5570 19000 2415 2285 10.7 10.1 AWM25G ALC25B 6450 22000 1905 8.4 2415 10.7 208 - 230 / 1 / 60 AIR FILTRATION COMPRESSOR TYPE REFRIGERANT TYPE REFRIGERANT CONTROL SOUND PRESSURE LEVEL HEIGHT DIMENSION WIDTH DEPTH WEIGHT TYPE LIQUID PIPE SIZE GAS 208 - 230 / 1 / 60 AWM20GR ALC20BR 5570 19000 5570 19000 48 31 9.52 / 3/8 260 / 10.2 899 / 35.4 198 / 7.8 12 ANTI-FUNGUS SKEW FAN 345 / 163 510 / 241 42 / 36 / 29 44 / 40 /36 306 / 12.0 1062 / 41.8 222 / 8.7 15 NANOSILVER-COATED ANTI-BACTERIAL SARANET FILTER NANOPHOTOCATALYST-COATED DEODORIZING SARANET FILTER NEGATIVE ION GENERATOR NON-THERMAL PLASMA (NTP) AIR STERILIZER ROTARY HERMETIC R22 CAPILLARY TUBE 49 52 494 / 19.4 646 / 25.4 740 / 29.1 840 / 33.1 270 / 10.6 330 / 13.0 34 57 FLARE VALVE 6.35 / 1/4 12.7 / 1/2 15.88 / 5/8 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) NOMINAL COOLING CAPACITY IS BASED ON THE CONDITIONS BELOW : COOLING : 27°C DB / 19°C WB INDOOR AND 35°C DB OUTDOOR 3) ALLOWABLE OPERATING RANGE: COOLING : 19.4°C DB / 13.9°C WB INDOOR AND 19.4°C DB OUTDOOR TO 26.7°C DB / 19.4°C WB INDOOR AND 46.1°C DB OUTDOOR 650 / 307 49 / 44 / 42 53 58 9.52 / 3/8 SPEC IFIC A T IO N S HEAT PUMP I NDOOR UNI T OUTDOOR UNI T NOMI NAL COOLI NG CAPACI TY NOMI NAL HEATI NG CAPACI TY POWER SOURCE I NPUT POWER RUNNI NG CURRENT COOLI NG ONLY COOLI NG HEATI NG COOLI NG HEATI NG I NDOOR UNI T POWER SOURCE I NPUT POWER RUNNI NG CURRENT FAN TYPE AI R FLOW SOUND LEVEL - H / M / L HEI GHT DI MENSI ON WI DTH DEPTH WEI GHT I NDOOR UNI T W Btu/ h W Btu/ h V/ Ph/ Hz W W A A A5WM09GR A5LC10CR 2640 9000 2640 9000 680 550 3.1 2.6 A5WM07G A5LC07C 2200 7500 OUTDOOR UNI T NOMI NAL COOLI NG CAPACI TY [R410A] A5WM07GR A5LC07CR 2200 7500 2200 7500 W Btu/ h V/ Ph/ Hz W A 620 2.9 cfm / L/ s dB(A) mm/ in mm/ in mm/ in kg 275 / 130 40 / 35 / 29 260 / 10.2 799 / 31.5 198 / 7.8 10 AI R FI LTRATI ON COMPRESSOR TYPE PROTECTI ON DEVI CE REFRI GERANT TYPE SOUND PRESSURE LEVEL HEI GHT DI MENSI ON WI DTH DEPTH WEI GHT (kg) PI PE OUTDOOR UNI T AI R TREATMENT DEVI CES dB(A) mm/ in mm/ in mm/ in A5WM15GR A5LC15CR 3520 12000 3520 12000 220 -240 / 1 / 50 865 865 1200 745 745 1080 3.9 3.9 5.4 3.4 3.4 4.9 A5WM09G A5WM10G A5WM15G A5LC10C A5LC10C A5LC15C 2640 2780 3520 9000 9500 12000 220 -240 / 1 / 50 865 865 1230 3.9 3.9 5.5 ANTI -FUNGUS SKEW FAN 300 / 142 345 / 163 39 / 34 / 28 42 / 36 / 29 260 / 10.2 899 / 35.4 198 / 7.8 12 NANOSI LVER-COATED ANTI -BACTERI AL SARANET FI LTER NANOPHOTOCATALYST-COATED DEODORI ZI NG SARANET FI LTER NEGATI VE I ON GENERATOR NON-THERMAL PLASMA (NTP) AI R STERI LI ZER ROTARY HERMETI C EXTERNAL OVERLOAD PROTECTOR 44 495 / 19.5 600 / 23.6 245 / 9.7 26 33 PI PE SI ZE LI QUI D GAS HEAT PUMP NOMI NAL HEATI NG CAPACI TY POWER SOURCE I NPUT POWER RUNNI NG CURRENT COOLI NG ONLY COOLI NG HEATI NG COOLI NG HEATI NG I NDOOR UNI T OUTDOOR UNI T NOMI NAL COOLI NG CAPACI TY POWER SOURCE I NPUT POWER RUNNI NG CURRENT FAN TYPE AI R FLOW SOUND LEVEL - H / M / L HEI GHT DI MENSI ON WI DTH DEPTH WEI GHT 35 FLARE VALVE 9.52 / 3/ 8 AWM07GR A4LC07BR 2230 7600 2170 7400 W Btu/ h W Btu/ h V/ Ph/ Hz W W A A 795 750 3.4 3.2 AWM07G A4LC07B 2170 7400 W Btu/ h V/ Ph/ Hz W A 855 3.6 cfm / L/ s dB(A) mm/ in mm/ in mm/ in kg 275 / 130 40 / 35 / 29 260 / 10.2 799 / 31.4 198 / 7.8 10 dB(A) mm/ in mm/ in mm/ in 47 AI R TREATMENT DEVI CES PI PE 28 TYPE PI PE SI ZE LI QUI D GAS A5LC25CR 6155 21000 6450 22000 1640 1550 6.8 6.6 A5WM20G 1900 1850 8.3 8.3 A5WM25G A5LC20C 5275 18000 A5LC25C 6155 21000 1630 6.8 1890 8.3 510 / 241 44 / 40 / 36 650 / 307 49 / 44 / 42 306 / 12.0 1062 / 41.8 222 / 8.7 15 BUI LT-I N OVERLOAD PROTECTOR 53 753 / 29.6 855 / 33.7 328 / 12.1 58 mm/ in mm/ in 12.7 / 1/ 2 15.88 / 5/ 8 4) ALLOWABLE OPERATI NG RANGE: COOLI NG : 19.4°C DB / 13.9°C WB I NDOOR AND 19.4°C DB OUTDOOR TO 26.7°C DB / 19.4°C WB I NDOOR AND 46.1°C DB OUTDOOR [R407C] AI R FI LTRATI ON COMPRESSOR TYPE PROTECTI ON DEVI CE REFRI GERANT TYPE REFRI GERANT CONTROL SOUND PRESSURE LEVEL HEI GHT DI MENSI ON WI DTH DEPTH WEI GHT (kg) A5WM25GR A5LC20CR 5275 18000 5275 18000 6.35 / 1/ 4 mm/ in mm/ in I NDOOR UNI T OUTDOOR UNI T NOMI NAL COOLI NG CAPACI TY A5WM20GR 52 651 / 25.6 855 / 33.7 328 / 12.1 57 540 / 21.3 700 / 27.6 250 / 9.8 TYPE SPEC IFIC A T IO N S I NDOOR UNI T R410A 49 46 1) ALL SPECI FI CATI ONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WI THOUT PRI OR NOTI CE. 2) ALL UNI TS ARE BEI NG TESTED AND COMPLY TO I SO 5151: 1994(E) 3) NOMI NAL COOLI NG CAPACI TY I S BASED ON THE CONDI TI ONS BELOW : COOLI NG : 27°C DB / 19°C WB I NDOOR AND 35°C DB OUTDOOR OUTDOOR UNI T A5WM10GR A5LC10CR 2780 9500 2780 9500 AWM15GR AWM20GR AWM25GR A4LC15BR A4LC20BR A4LC25BR 3225 5130 6010 11000 17500 20500 3665 5570 7035 12500 19000 24000 220 -240 / 1 / 50 975 2185 2775 1440 825 1290 2280 2750 4.3 6.6 10.3 13.5 3.6 6.1 10.9 13.4 AWM10G AWM15G AWM20G AWM25G A4LC10B A4LC15B A4LC20B A4LC25B 2640 3225 5365 6155 9000 11000 18300 21000 220 -240 / 1 / 50 1440 2295 2860 975 4.3 6.6 10.7 13.4 ANTI -FUNGUS SKEW FAN 300 / 142 345 / 163 510 / 241 650 / 307 39 / 34 / 28 42 / 36 / 29 44 / 40 / 36 49 / 44 / 42 260 / 10.2 306 / 12.0 899 / 35.4 1062 / 41.8 198 / 7.8 222 / 8.7 12 15 NANOSI LVER-COATED ANTI -BACTERI AL SARANET FI LTER NANOPHOTOCATALYST-COATED DEODORI ZI NG SARANET FI LTER NEGATI VE I ON GENERATOR NON-THERMAL PLASMA (NTP) AI R STERI LI ZER ROTARY HERMETI C BUI LT-I N OVERLOAD PROTECTOR EXTERNAL OVERLOAD PROTECTOR R407C CAPI LLARY TUBE 52 53 48 49 646 / 25.4 494 / 19.4 840 / 33.1 740 / 29.1 330 / 13.0 270 / 10.6 57 58 31 34 FLARE VALVE 9.52 / 3/ 8 6.35 / 1/ 4 15.88 / 5/ 8 9.52 / 3/ 8 12.7 / 1/ 2 1) ALL SPECI FI CATI ONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WI THOUT PRI OR NOTI CE. 2) ALL UNI TS ARE BEI NG TESTED AND COMPLY TO I SO 5151: 1994(E) 3) NOMI NAL COOLI NG CAPACI TY I S BASED ON THE CONDI TI ONS BELOW : COOLI NG : 27°C DB / 19°C WB I NDOOR AND 35°C DB OUTDOOR AP - AWM - G - 06A AWM10GR A4LC10BR 2640 9000 2785 9500 4) ALLOWABLE OPERATI NG RANGE: COOLI NG : 19.4°C DB / 13.9°C WB I NDOOR AND 19.4°C DB OUTDOOR TO 26.7°C DB / 19.4°C WB I NDOOR AND 46.1°C DB OUTDOOR www.acson-international.com