Z 50 AC 06 WARNINGS 07 ! DISCONNECT AND UNPLUG TEST LEADS before opening case. TEST NCV FUNCTION ON KNOWN LIVE WIRE before using. DO NOT APPLY VOLTAGE greater than 30VAC or 60VDC to the thermocouple or the jacks when the rotary dial is on °F°C. (Use only Type K thermocouples) DO NOT APPLY VOLTAGE TO THE JACKS when the rotary dial is on microamps. Even low voltages can cause a current overload and potentially harm the meter. Temperature (°F/°C) MFD NCV °F°C COM Plug any Type K thermocouple directly into the meter to measure temperature. Cold junction is located inside the meter and allows for extremely accurate measurements even in rapidly changing ambient temperatures (going from rooftop to freezer). No adapter is required. Range: -30°F to 932°F, (-35°C to 500°C) Resolution: 0.1° Accuracy: ±(1°F)* 32°F to 120°F, ±(1°C) 0°C to 49°C ±(1%+2°F) 32°F to 572°F, ±(1%+1°C) 0°C to 300°C ±(2%+6°F) -30°F to 32°F, ±(2%+3°C) -35°C to 0°C ±(2%+6°F) 572°F to 932°F, ±(2%+3°C) 300°C to 500°C Sensor type: Type K thermocouple *After field calibration Overload protection: 30 VDC or 30VAC rms 30V MAX COM 10 V 30 X MA T III CA600V MP OFF TE M CO TO pie Voltage AC (VAC) (50Hz-500Hz) PE TY K- AU ld Ho MFD NCV °F°C HZ AAC VAC VDC HZ% µADC ce MFD NCV °F°C HZ AAC VAC VDC HZ% µADC Use NCV to check 24VAC from a thermostat or live voltage up to 600VAC. Always test a known live source before using. A segment graph and RED LED will display the presence of voltage. Audible beep increases from intermittent to continuous as intensity of field (EF) increases. AC Voltage Detection Range: 24VAC to 600VAC (50-60Hz) 09 30V MAX Unplug Leads and Slide TEMP Switch to the Right Non Contact Voltage (NCV) Test power lines (120, 220, 480), test 24V going to controls, and test for transformer failure. Ranges: 500mV, 5V, 50V, 500V, 600V Resolution: 0.1mV Accuracy: ±(1.2% + 8) 500mV range (50-60Hz) ±(1.2%+8), 5V, 50V, 500V; ±(1.5% + 8) 600V range True RMS: model SC440 only Crest factor: ≤ 3 Audio/Visual Hi-V indicator: >30VAC/VDC Input impedance: >100MΩ (500mV), 10MΩ (5V), 9.1MΩ (50V-600V) AUTO OFF TYPE K 0 COM HZ AAC VAC VDC HZ% µADC S RM AUTO OFF TYPE K Please operate the instrument following all instructions of the operator's manual to avoid impairing the safety of the product. 08 30V MAX 44 SC NCV AUTO OFF TYPE K ld Backlight: 60 second duration with auto-off. Blue color. SC440 only. Overrange: (OL) or (-OL) is displayed Measurement rate: 3.3 times per second, nominal Zero: Automatic Operating environment: 32°F to 122°F (0°C to 50°C) at <70% relative humidity Storage temperature: -4°F to 140°F (-20°C to 60°C), 0 to 80% RH (with battery removed) Accuracy: Stated accuracy @ 73°F±9°F (23°C±5°C), <75%RH Temperature coefficient: 0.1 x (specified accuracy) per °C [0°C to 19°C (32°F to 66°F), 28°C to 50° C(82°F to 122°F)] APO (Auto Power Off): Approx. 30 minutes Power: Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22 Battery life: 200 hours typical alkaline (SC420); 100 hours typical alkaline (SC440) Low battery indication: Battery icon blinks and "LO.bt" is displayed when the battery voltage drops below the operating level Dimensions: 233mm(H) x 79mm(W) x 45mm(D) Weight: Approx. 315g including battery Altitude: Up to 6562 ft (2000m) Overload protection: 600 VDC or 600VAC rms unless otherwise stated Test leads: Use UL listed test leads that comply to UL61010-031 rated CATIII 600V or above. Included test leads are gold-plated and have removeable safety caps. 05 Fie Never ground yourself when taking electrical measurements. Do not touch exposed metal pipes, outlets, fixtures, etc., which might be at ground potential, while taking measurements. Keep your body isolated from ground by using dry clothing, rubber shoes, rubber mats, or any approved insulating material. Disconnect the test leads before opening the case. Inspect the test leads for damage to the insulation or exposed wire. Replace if suspect. Keep your fingers behind the finger guards on the probes while taking measurements. When disconnecting from a circuit, disconnect the“RED”lead first, then the common“BLACK” lead. Use one handed testing when possible. Work with others. Turn off power to the circuit under test before cutting, unsoldering, or breaking the circuit. Do not measure resistance (ohms) when circuit is powered. Isolate load by disconnecting from circuit. Disconnect the meter from circuit before turning any inductor off, including motors, transformers, and solenoids. High voltage transients can damage the meter beyond repair. Freeze the display. Hold 30V MAX Functions Specifications Display: 5000 count dual display Do not use during electrical storms. Do not apply more than rated voltages between input and ground. Isolate capacitors from system and discharge them safely before testing. Temperature switch prevents leaving thermocouple plugged in while measuring voltage. When measuring high frequency AC current, do not exceed the rated 400AAC of the clamp. Failure to adhere may cause the clamp to heat up dangerously. All voltage tests: All voltage ranges will withstand up to 600V. Do not apply more than 600VDC or AC rms. Symbols used: Caution, risk of electric shock ! Caution, refer to manual. Ground Double insulation 600V 600V UE TR TRUE RMS TRUE RMS SC640 e ng Ra AUTO OFF SC640 04 CAT CATIIIIII Manually select a range. Hold Select COM 600V 30V MAX HZ % AAC DC VAC V HZµADC Range TYPE K TEMP TEMP t AUTO OFF TYPE K FD M V NC °C °F µADC elec 30V MAX VDC S % K-TYPE CAT III MAX 30V % K-TYPE MAX TEMP 600V TRUE TRUERMS RMS AUTO AUTOOFF OFF CAT III Activate inrush current and scroll TEMP 600V 30V 30V CAT III K-TYPE K-TYPE MAX MAX inrush ranges through different (SC440). 600VIII CAT HZ °F °C DC µADC °F °C INRUSH COM Safety Information HZ Hold SC640 Range 03 HZ 400 AAC VACHold VAC TRUE RMS Z 400 AC AC COM 02 Z AC AC AUTO OFF 01 TRUE RMS 50 TYPE K 600V CATIII 600V, class II and pollution degree 2 indoor use comply with CE, RoHS compliant. CATIII is for measurements performed in the building installation. µADC °F °C TRUE RMS CAT III WEEE VDC HZ SC640 TEMP 30V MAX C-Tick (N22675) µADC Range COM AUTO OFF MFD °F °C Se lec t TYPE K NCV % HZ 50AAC VAC HZ 400 AAC VAC µADC SC440 VDC HZ °F °C TRUE RMS Hold MFD VDC Range HZ 50AAC VAC HZ 400 AAC VAC NCV INRUSH Se lec t EN61010-1 EN61010-2-032 EN61010-2-033 EMC EN61326-1 Auto Power Off Enabled INRUSH INRUSH High Voltage Warning (>30VAC/VDC) Manual Range (RNG) Mode SEL Data Hold Mode SEL SEL Inrush Amps Mode (Model SC440) Continuity Test SEL SEL Diode TestOFF TRUE RMS AUTO TRUE RMS AUTO OFFOFF TRUE AUTO 30V RMS Frequency Test (hertz) 30VMAX K-TYPE SEL SEL 30V K-TYPE MAX K-TYPE MAXOFF Resistance Test (ohms) TEMP TRUE RMS AUTO TRUE RMSOFF AUTO TEMP OFF TEMP Capacitance Test (farads) 30V RMS TRUE RMS30VAUTO AUTO OFFK-TYPE TRUE OFF K-TYPE MAX CAT IIICycle Test (percentage) MAX Duty CAT III 30VTEMP CAT III TRUE AUTO OFF 30V TRUE RMS AUTORMS OFF 600V TEMP 600V K-TYPE K-TYPE MAX 600V Unit (10−6, one millionth) MAX Rotate dial to%the function you want to Micro TEMP 30V 30Vuse. TEMP K-TYPE K-TYPE OFF MAX CAT IIIMAX CAT III Milli Unit (10−3, one thousandth) TEMP TEMP 600V 600V CAT III CAT III KiloOFF Unit (103, one thousand) C y c l e t h r o u g h p a r a m e t e r 600V s600V TRUE RMS AUTO Se lec CAT III III Mega Unit (106, one million) CAT t within VAC/AAC/Hz and Ω/ / TRUE RMS 30V AUTO 600VOFF 600V % K-TYPE HHold MAX OFF Range switch positions. A 30V RMS AUTO TRUE OFF TEMP H V K-TYPE SC640 MAX A NCV V TRUE RMS AUTO TEMP OFF 30V K-TYPE MFD V TRUE RMS AUTO OFF MAX CAT III OFF H Illuminate backlight (SC440). 30V A TEMP 600V INRUSH UL 61010-1, Third Edition HZ AAC VAC VDC HZ% µADC MFD NCV °F°C HZ HZ AAC VAC VDC HZ% µADC °C °C °F °F INRUSH MFD NCV °F°C %% INRUSH Models SC440 SC420 Certifications Fieldpiece Display MFD Controls MFD Hz Hz The new SC400 series clamp meters are designed for HVACR service. Hang clamp meter to any metallic surface with the redesigned heavy-duty magnet and keep your hands free to do more (SC440 only). See both voltage and amperage readings at the same time on the dual LCD display, even in low light conditions using the bright blue backlight (backlight SC440 only). Take measurements with one hand using the single test lead holder for added safety. Test leads come with removable gold plated tips to connect with Fieldpiece accessory heads. Take more accurate VAC and AAC readings on VFDs with True RMS sensing technology (SC440 only). Measure the starting amp draw of a compressor with Inrush current feature (SC440 only). Find the wire you want to test with the automatic clamp jaw light (SC440 only). The SC400 series clamp meters are built toSelect NCV withstand the rigors of HVACR with high impactRange MFD plastic and a display you can read in hot or cold environments. Move from a cold freezer to a hot roof top and get accurate temperature measurements that lesser thermometers canSe lec t not measure properly. MFD Essential Clamp Meters OPERATOR'S MANUAL Description 1.For electrical testing, connect test leads to "COM" and "+" jacks. 2. Rotate the dial to your desired measurement. 3. Connect to test points and read measurement. 4. For temperature testing, remove test leads, slide TEMP switch to the right and connect Type K thermocouple. HZ 50AAC VAC HZ 400 AAC VAC Quick Start OFF Fieldpiece O F Hz AAC SEL SEL SEL INRUSH F VAC AAC VDC NCV MFD °F°C% Hz HOLD HOLD %MFD°C F VAC V DC INRUSH NCV OO Hz Hz % Hz °F SEL NCV SEL FF AAAC °CHz AC INRUSH °F °C AC AC°F FFVV VV DC DC SEL SEL INRUSH Battery Life (replace 9V if blinking) NCV NCV INRUSH SEL SEL F AAC F VAC VDC MFD SC56 % NCV Hz °F°C Select VDC and measure DC voltages on circuit boards on more INRUSH advanced HVACR systems. Ranges: 500mV, 5V, 50V, 500V, 600V Resolution: 0.1mV Accuracy: ±(0.5% + 2) HOLD Input impedance: O Hz >100MΩ (500mV), 10MΩ (5V), F A AC 9.1MΩ (50V-600V) F VAC VDC MFD % NCV Hz °C °F Used for “ohming out” aSEL compressor. 0.1Ω resolution is necessary INRUSH to test the resistance between the motor poles because the values are typically very low. Ranges: 500Ω, 5kΩ, 50kΩ, 500kΩ, 5MΩ, 50MΩ Resolution: 0.1Ω Overload Protection: 600VDC or 600VAC rms Accuracy: ±(1.0% + 5) 500Ω to 500kΩ, ±(1.5% + 5) 5MΩ, ±(3.0% + 5) 50MΩ Voltage DC (VDC) Check incoming voltages to ensure they are cycling at 60Hz. For frequency measurements on VFD equipment, use the amp clamp. Ranges: 500Hz, 5kHz, 50kHz, 500kHz, 1MHz Resolution: 0.1Hz Accuracy: ±(0.1% + 5) Sensitivity: 10Hz to 1MHz: >3.5Vrms PW: >1µs Duty Cycle Limits: >30% and <70% MFD NCV °F°C HZ AAC VAC VDC HZ% µADC Capacitance (MFD) MFD NCV °F°C English Metric Ft/min MPH ºF M/s KM/hr ºC READ Metric Real time OFF MFD NCV °F°C HZ AAC VAC VDC % HZ µADC AUTOOFF AAV3 Select Hold Range TRUE RMS SC440 AUTO OFF TYPE K 30V MAX TEMP COM CAT III 600V Visit www.fieldpiece.com to see all of the different accessory heads that Fieldpiece offers. 16 17 HOLD LO BATT Air Velocity & Temperature Average English (16 sec) Head Fieldpiece MFD NCV °F°C HZ AAC VAC VDC HZ% µADC Auto power off or APO will automatcially turn off your meter after 30 minutes of inactivty. By default it is activated and APO will show on the display. To disable, turn meter off. Hold and SC240 power on the meter by turning the selector dial to any range. Release after the beep. APO will no longer displaySC240 over the battery icon. MFD OFF HZ 400 AAC VAC VAC NCV MFD HZ 50AAC M/m HZ % µADC OFF Auto Hold NCV Se lec t HZ 50AAC VAC HZ 400 AAC VAC MFD VDC This meter is warranted against defects in material or workmanship for one year from date of purchase. Fieldpiece will replace or repair the defective unit, at its option, subject to verification of the defect. This warranty does not apply to defects resulting from abuse, neglect, accident, unauthorized repair, alteration, or unreasonable use of the instrument. Any implied warranties arising from the sale of a Fieldpiece product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above. Fieldpiece shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim of such damage, expenses, or economic loss. State laws vary. The above limitations or exclusions may not apply to you. AUTO OFF TYPE K TEMP 30V MAX Press and hold for two seconds. Meter AUTO OFF will beep andSC640 HOLD will blink on LCD. After 6 seconds the measurement on screen will freeze automatically. Press to exit this mode. Range A HZ Hold TRUE RMS °F TYPE K % µADC 30V °C MAX TEMP COM COM CAT III 600V Se lec t Range CAT III 600V TRUE RMS Hold SC640 Battery Replacement AUTO OFF DO NOT SWITCH FROM J2 30V MAX When your meter’s battery is low, the battery icon will appear empty and blink for 30 seconds. AUTOmeter OFF “LO.bt” will display and will power off. Turn dial to OFF position, disconnect test leads and remove the battery cover with magnet strap (SC440 only) on the back of your meter. Remove old battery and replace with a standard 9V battery only. Be sure to re-insert the magnet strip before re-installing the battery cover. TYPE K COM C TYPE K 30V MAX COM TEMP CAL B 18 30V MAX Hold AUTO K TYPE RMS VDC µADC SC640 TRUE HZ % OFF Range °F °C HZ AC HZ 50A VAC 400AAC VAC COM OFF INRUSH 19 Inrush feature captures starting current of a compressor motor. Starting current can assist in diagnosing a motor before it fails. To activate Inrush feature 1. Turn selector switch to VAC/AAC/Hz 2. Press SELECT once to show AAC on upper display. 3. Press INRUSH once to select 50AAC range. Press INRUSH twice to select 400AAC range. 4. Clamp meter around compressor start wire. Turn motor on. The starting current will hold on the upper display. 5. Hold INRUSH for 2 seconds to exit Inrush feature or press and release INRUSH to measure starting current again. Inrush measurement period: 100-milliseconds Minimum input: >2A on 50A range; >20A on 400A range ! Note: AAC through the clamp and voltage through the test leads can be measured simultaneously. However, if only AAC, Frequency (Hz), or Inrush is measured through the clamp, test leads and thermcouple must be unplugged from the meter. Call Fieldpiece Instruments for one-pricefix-all out-of-warranty service pricing. Send check or money order for the amount quoted. Send the meter freight prepaid to Fieldpiece Instruments. Send proof of date and location of purchase for in-warranty service. The meter will be repaired or replaced, at the option of Fieldpiece, and returned via least cost transportation. For international customers, warranty for products purchased outside of the U.S. should be handled through local distributors. Limited Warranty e Rang ge M/mVDC Ran Select °F °C Select HZ AAC VAC VDC HZ% µADC Obtaining Service Clean the exterior with a dry cloth. Do not use liquid. AAC VAC VDC NCV °F°C 15 Maintenance AAC VAC VDC NCV °F°C INRUSH LCD X 100 HOLD ON MFD Fieldpiece INRUSH MFD NCV °F°C HZ AAC VAC VDC HZ% µADC Fieldpiece Auto Power Off For accuracies of ±1°F, calibrate to a known temperature. A glass of stabilized ice water is very close to 32°F (0°C) and is usually very convenient but any known temperature can be used. 1. Select the °F °C range. 2. Plug thermocouple to be calibrated into the Type K jack. 3. Unscrew A and B and remove the battery cover. 4. Stabilize a large cup of ice water. Stir the ice with the water until temperature stays at a stable value. 5. Immerse the thermocouple probe and let it stabilize. Keep stirring water to prevent micro-environments. 6. Do not let the thermocouple come in direct contact with ice. 7. Use a small screwdriver to adjust calibration pot C below the battery as close to 32°F (0°C) as you would like. Note: J1-J2 switch is for autocalibration purposes only. Do not switch from J2. HZ AAC VAC VDC HZ% µADC 14 K-TYPE CAT III 600V Temp. Calibration Your new Swivel Clamp Meter is compatible with all Fieldpiece Accessory Heads. With Fieldpiece Accessory Heads, you can measure any available parameter, and read the measurement on your new meter's display in real-time. Just set the range to VDC and press the RANGE button until mV is displayed. Remove the probe tips of your test leads, and connect your accessory head (model AAV3 shown). TEMP MFD NCV °F°C K-TYPE TEMP Test diodes forIIIproper forward and reversed-biased functions. CAT Test current:600V 0.8mA (Approx.) Accuracy: ±(1.5% + 5) Open circuit volts: 3.2VDC typical Audible beep: <0.03V Visual Indicator: Green LED Overload 600VDC or 600VAC rms TRUE RMS Protection: AUTO OFF 30V 13MAX HZ AAC VAC VDC HZ% µADC MFD NCV °F°C Diode Test ( ) Discharge Cap First! 12 Modular Expandability 30V MAX HZ AAC VAC VDC HZ% µADC Measure Hz on variable frequency drive motors. Turn dial to VAC/ AAC/Hz and press SELECT twice. Hz will show in upper display. Range: 10Hz to 400Hz Accuracy: ±(0.1% + 5) Minimum current range: > 5AAC Overload Protection: 400AAC Resolution: 0.1Hz Inrush Current (SC440 only) Use the continuity feature to test if a circuit is open or closed. Use this feature to check fuses as well. A steady “beep” and green LED indicate you have continuity. Press SELECT once. Range: 500Ω Resolution: 0.1Ω Response time: 100ms AudibleRMS beep: <30Ω Overload TRUE AUTO OFF Protection: 600VDC or 600VAC rms Duty cycle shows the % On Time of a 5V logic signal square wave. Ranges: 5%-95% (40Hz to 10kHz), 10%-90% (10kHz to 20kHz) Accuracy (5V logic): ±(2% + 10) Resolution: 0.1% PW: >10µs Overload Protection: 600VDC or 600VAC rms 11 MFD NCV °F°C Continuity SEL ( ) Duty Cycle (%) Test any isolated power line. Press SELECT on VAC/AAC/Hz position. Read AAC in upper display. True RMS on SC440 only. Ranges: 50A, 400A Resolution: 0.01A Crest factor: ≤ 3 Accuracy: ±(2.0% + 10) 50-60Hz Jaw Opening: 1.2in (30 mm) Frequency (Hz) Through Clamp Resistance (Ω) Frequency (Hz) Through Leads Set to MFD to test motor start and run capacitors. Capacitors are one of the most failure prone components in a HVACR system. Disconnect from power and resistors between terminals. Discharge capacitor before testing. If dIS.C is displayed, capacitor is not discharged completely. Ranges: 5µF, 50µF, 500µF, 5mF Resolution: 1nF Accuracy: ±(3% + 15) 5µF, ±(3% + 5) 50µF to 500µF, ±(5% + 20) 5mF Overload Protection: 600VDC or 600VAC rms MFD NCV °F°C Select MFD NCV °F°C HZ AAC VAC VDC HZ% µADC Amps AC (AAC) True RMS HZ AAC VAC VDC HZ% µADC MFD Microamps for flame rectifier diode test on a heater control. Connect leads between flame sensor probe and control module and turn heating unit on to read µA measurement. When the flame is on, there should be a measurable µADC signal, typically under 10µADC. Compare measurement to manufacturer’s specification to determine if replacement is necessary. Ranges: 500µA Resolution: 0.1µA Accuracy: ±(1.0% + 2) Voltage burden: 1V Overload Protection: 600VDC or 600VAC rms NCV MicroAmps DC (µADC) www.fieldpiece.com © Fieldpiece Instruments, Inc 2014; v21 20
Similar documents
User Manuals - Fieldpiece Instruments
APO (Auto Power Off): Approx. 30 minutes Power: Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22 Battery life: 200 hours typical alkaline (SC620); 100 hours typical alkaline (SC640) Lo...
More informationOperations Manual - Fieldpiece Instruments
Battery life: 200 hours typical alkaline (SC220/SC240); 150 hours typical alkaline (SC260) Low battery indication: Battery icon blinks and "LO.bt" is displayed when the battery voltage drops below ...
More informationWireless Clamp Meter - Fieldpiece Instruments
advanced HVACR systems and logic control boards. In ADC/VDC dial position, VDC is shown on lower display. Press SELECT button to show ADC on the top display at the same time. Ranges: 1000mV, 10V, 1...
More information