pages - Ares Make
Transcription
pages - Ares Make
DIRECT FIRED SUBMITAL INDEX Index Page 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 27 28 29 30 31 32 33 34 35 36 37 38 39 41 43 45 47 Description Index ARES DFG Make Up Air Specification Page 1 ARES DFG Make Up Air Specification Page 2 Direct fired Small (ADF 9), CFM range 800 to 3250 9 Unit 9 Unit w/optional inlet damper 9 Unit w/hood 9 Unit w/v-bank and optional inlet damper 9 Unit w/hood and optional inlet damper 9 Unit w/hood, v-bank and optional inlet damper 9 Unit w/CEV 6000 Stainless Steel Evaporative Cooler up to 6000 CFM 9 Unit w/Inlet Damper and CEV 6000 Stainless Steel Evaporative Cooler up to 6000 CFM Direct fired Medium (ADF 15), CFM range 2750 to 8500 15 Unit w/optional inlet damper 15 Unit w/v-bank and optional inlet damper 15 Unit w/hood and optional inlet damper 15 Unit w/hood, v-bank and optional inlet damper 15 Unit w/Top discharge (special) 15 Unit w/Inlet damper & CEV6000 Stainless Steel Evaporative Cooler up to 6000 CFM 15 Unit w/Inlet damper & CEV6000 (no transition) Stainless Steel Evaporative Cooler up to 6000 CFM 15 Unit w/Inlet Damper & CEV12000 Stainless Steel Evaporative Cooler up to 12000 CFM Direct fired Large (ADF 20), CFM range 8000 to 16000 20 Unit w/optional inlet damper 20 Unit w/v-bank and optional inlet damper 20 Unit w/hood and optional inlet damper 20 Unit w/hood, v-bank and optional inlet damper 20 Unit w/Inlet damper & CEV12000 Stainless Steel Evaporative Cooler up to 12000CFM Accessories/Misc. Discharge damper for unit 9, 15 and 20 Roof curb drawing for unit 9, 15 and 20 Roof curb w/exhaust fan by others for unit 9, 15 and 20 9 Unit fan curve 15 Unit fan curve 20 Unit fan curve Remote control drawing for 9-15-20 unit Piping diagram single burner STD and FM/IRI Piping diagram multi-burner STD Piping diagram multi-burner FM/IRI (optional) High CFM unit A5-D2500-925 Horizontal w/inlet damper & v-bank High CFM unit A5-D2500-925 horizontal w/hood, V-bank and inlet damper High CFM unit A5-D2500-925 down discharge w/hood, v-bank and inlet damper Typical wiring diagram for 120-1 volt unit 9-15-20 Typical wiring diagram for 208-1 volt unit 9-15-20 Typical wiring diagram for 3 phase unit 9-15-20 Direct Fired Work Sheet Drawing Number ADF-NDX02/16/05 ADF-SPEC1 ADF-SPEC2 ADF9 ADF9I ADF9H ADF9VI ADF9HI ADF9HVI ADF9CEV6 ADF9ICEV6 ADF15I ADF15VI ADF15HI ADF15HVI ADF15T ADF15ICEV6 ADF15ICEV6NT ADF15ICEV12 ADF20I ADF20VI ADF20HI ADF20HVI ADF20ICEV12 ADF-MBD ADF-SRC ADF-CRC ADF9FC ADF15FC ADF20FC ADF-RC rev ADF PIPING1 ADF PIPING2 ADF PIPING3 A5-IND-VB A5-HOR-VB-IS A5-DD-VB WD-115V-1PH WD-1PH WD-3PH ADF-WS ADF-NDX 021605 This Page is blank ARES DIRECT FIRED MAKE-UP AIR SPECIFICATION ARES DIRECT FIRED MODEL NUMBERS * 9 * 15 * 20 (NOTE: Some additional model numbers & letters are necessary when design conditions. Consult factory for modified model number.) GENERAL The ARES Direct Fired Series Heated Make Up Air Unit is an ETL Listed direct-fired gas-burning unit for use in tempering make-up air for installations requiring frequent air changes. The units conform to ANSI Z83.4a – 2001 / CSA 3.7a - 2001 standards, and produce from 16,000 BTU/hour to 1,650,000 BTU/hour depending on energy requirements. Units are ETL listed for natural gas and liquid propane applications. The heaters are intended for indoor or outdoor installations in commercial kitchens, factories, foundries, and similar commercial and industrial occupancies where unvented open-flame combustion equipment is permitted. They are intended to be installed and used in accordance with the Standards of the National Fire Protection Association, NFPA No. 54 and the National Fuel Gas Code. The unit is ETL Listed for horizontal unit with horizontal, down or top discharge air direction and in combination with centrifugal upblast exhaust fan (by others). Each unit is equipped with controls having the capabilities of stand-alone operation, or interfacing with the total integrated system controls. Units consist of a casing with a gas burner or burners suspended approximately in the center, which burns directly in the outside air stream. The products of combustion mix with the make-up air, which is introduced into the heater intake directly from outside the building, and a centrifugal-type blower forces the resultant mixture into the building. Units are provided with a hot surface-ignited burner. In the event of flame outage, all gas is shut off to the main burner. Units are factory assembled, tested, and shipped as a complete package, consisting of the following. a. b. c. d. e. f. g. Gas burner DWDI Centrifugal blower AMCA Certified Motor and adjustable drive assembly Fuel burning safety equipment Temperature control system Gas piping Contactor, and overload (for three phase application, when required) h. i. j. Optional external service disconnect with integrated auxiliary contacts for control circuit (when required) Optional intake hood with birds screen (maybe shipped separate for field mounting by others) 1” thick, UL Listed, Class 2 washable filter CASING 1. 2. 3. 4. 5. 6. Units are constructed of G-90 galvanized, 20-gage steel. All casing panels are attached with sheet metal screws. Units are built with drop-over support frame 12 and/or 14 gage G90 galvanized, suitable for mounting on roof curbs. An observation port is located on the exterior of the unit to observe the main flame. Access panels are gasketed hinged and lift off, with drawdown tight locks, water resistant access panels provides access to all internal components. Hinged and easily removable access panels are provided to allow servicing of the blower/motor/drives, and manifold/electrical components. Insulation is UL Listed Class 1, 1” 1-1/2 pounds foil face fiberglass insulation (optional). BLOWER AND DRIVES 1. 2. Blowers are forward curved, belt driven, double width, double inlet, and class II centrifugal type and contain cast iron pillow block lubricated Stainless Steel ball bearings (150,000 hours average life). Blowers are constructed of galvanized steel covered with an enamel finish. Motor sheaves are adjustable for balancing. Blower sizes are 9” 15” and 20” DWDI FC. Blowers are factory tested and set at rated speed after installation in the factory-assembled unit. Blower shafts are equipped with keyways. MOTOR 1. UL recognized motors have thermal or amperage protection and are high efficiency open drip proof type with adjustable drives and motor mount. Adjustable pulleys and heavy-duty belt(s) are standard. BURNER 1. 2. 3. The gas burner is a direct-fired draw through type, and is sized to provide desired output using natural gas at an inlet supply pressure to the unit of 13.5” water column max, or 11” for propane. The gas burner has a maximum discharge temperature of 100°F natural gas and 90°F liquid propane. The flame extends the entire length of the burner at all times when the system is in operation. The burner consists of non-clogging stainless steel combustion baffles attached to a cast iron gas supply section with no moving parts. The burner is capable of 100% thermal efficiency with a maximum turndown ratio of 100 to 1 per 3-burner unit (1,650 MBTUH). 4. 5. A smart valve with hot surface ignition and flame rod is used to prove flame. A dependable ceramic Nitride composite igniter is used to initiate combustion. WIRING AND ELECTRICAL 1. 2. 3. The control circuit voltage is 115-1-60 and 24V grounded and 24V non-grounded. Control transformers are provided. Wiring in control enclosures is in accordance with the National Electrical Code. The unit is shipped complete with all items such as relays, starters, switches, and safety controls as required for proper operation. All factory-mounted controls are factory pre-wired to the unit control panel. All loose controls must be field installed and wired in accordance with the manufacturer’s specifications and/or local codes. CONTROL SYSTEM The ARES sophisticated Micro Controller provides digital logic to the next level of temperature control. The ARES Micro Controller has been engineered with digital technology to provide accuracy of 99%. Burners 550 MBH and below have an approximate 30 to 1 turndown, 1,100 to 550 MBH have an approximate 60 to 1 turndown and units 1,650 to 1,100 MBH have an approximate 100 to 1 turndown. With the Micro Controller technology ARES unit is the cleanest burning direct fired unit manufactured. The Micro Controller comes standard with a service switch, Off/Auto/Fan switch, and discharge set point slide 55°F to 100°F. The technology allows the Micro Controller to troubleshoot the complete system by referencing labeled LED’s. These LED’s show you immediately the reason for failure. The standard warning LED’s on the Micro Controller are “Fan Enable”, “Freeze Relay”, “Burner Statues Relay” and optional “Cooling”. The “COOLING” option is available only on one and two burner model. The Cooling option requires a relay to energize the ARES EVAP cooling system or DX coils provided by others. An optional remote control station also provides labeled LED’s. These LED’s are “Fan On”, “Heat On”, “Freeze Shutdown” and optional “Clogged Filter”. A low temperature room override option is available for the remote control station, (if the space temperature falls below room override t-stat setting, it will override the duct stat set point and drive the burner to high fire until the space temperature is satisfied). The Micro Controller can be hard wired to any EMS system at no additional charge. If you would like to communicate with a specific EMS system you must contact factory for specific details. The ARES Micro Controller intelligent programming cycles the burners on and off as needed. This allows maximum energy savings because it supplies the precise BTU’s to provide the desired comfort. To provide this comfort and savings the Micro Controller monitors inlet air and discharge air temperatures checking them at 20 intervals a second providing a constant defined temperature. The signal from the Micro Controller is sent to the ARES exclusive amplifier, this amplifier processes the signal to control the modulating gas valve. On two and three burner units the processor sends a signal to an on/off valve controlling it as needed and modulating at least one burner to provide the precise BTU’s for the desired comfort. The ARES Micro Controller has two exclusive features, the first feature, FREEZE PROTECTION. If the discharge temperature drops to 40°F or less for four continuous minutes the unit will halt all its functions until it is reset. Reset is accomplished by positioning the selector switch to the “OFF” mode on the Micro Controller until the Freeze LED turns off. The second feature, MILD WEATHER LOCKOUT, will disable the burner when the ambient temperature is within two degrees below set point. The modulating burner will start again when the temperature is 5°F below set point. STEPPED DIRECT IGNITION SYSTEM 1. 2. Employs hot surface ignition with flame rectification to main burner. High reliability with fewer gas handling parts (reduces possibility of leakage). ENCLOSURERS AND WEATHER PROOFING 1. 2. 3. 4. The ETL Listed unit is provided for outdoor or indoor installation, with factory mounted controls inside the unit casing and control enclosures. The unit construction is a fully weatherproof design. The burner control vestibule includes full size, gasketed hinged access panels that require the use of a tool to open, to gain access to controls and gas train components. The blower section includes a full size gasketed-hinged access panel that requires the use of a tool to open, to gain access to the blower, motor, and drives. A roof curb can be provided, specifically designed for installation of the unit furnished to provide a fully weatherproof design. FACTORY TESTS All units are operated, tested and set at the factory using specified job site conditions for electrical and gas input. All operating and safety controls are tested and set at the factory. Adjustable sheaves are set for proper RPM at specified conditions. The gas pressure regulator is set for specified burning rate. NOTE: Since field conditions may vary from submitted specifications, the “Start up Check List” must be completed to insure proper operation and warranty validation at specified inlet pressure (this is found in the control cabinet shipped with the unit). ADF-SPEC2 11/06/03 This Page is blank Performance curves based on tests made in accordance with A.M.C.A. 210-85. Tested with discharge duct. Horsepower does not include drive loses. Standard air density 0.075 Lb/Cu. Ft. External static pressure to unit and unit accessories (Inches W.C.). You must add the accessories static pressure losses to the ARES unit. (See chart below) The fan curve includes all internal loses and with your required unit accessories (Job specific) from the chart below will you will then get the total external static pressure or total system static pressure. Inlet Hood with Filters .25" W.C. Inlet Damper .13" W.C. Discharge Damper .15" W.C. V-bank filter Box .25" W.C. CEV .25” W.C. Cabinet .50” W.C. These are estimated values and may vary based on actual condition and CFM. ARES DIRECT FIRED MODEL 9 (9” x 9” DWDI FC) AIR REPLACEMENT ENGINEERED SYSTEMS 3.00 2000 2.50 1900 2.25 1800 2.00 1700 1.75 ) 3 1600 Curve(s 1.50 1500 System 14 0 0 1300 2 .75 1/ 1- 1.00 2 1.25 1200 1 External Static Pressure (In. W.G.) 2.75 3/ 1000 .25 1 1/ 3 RPM H 4 1100 .50 /2 P .00 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 Volume (CFM - 00's omitted) ADF9-FC 11/19/03 TJ Performance curves based on tests made in accordance with A.M.C.A. 210-85. Tested with discharge duct. Horsepower does not include drive loses. Standard air density 0.075 Lb/Cu. Ft. External static pressure to unit and unit accessories (Inches W.C.). You must add the accessories static pressure losses to the ARES unit. (See chart below) The fan curve includes all internal loses and with your required unit accessories (Job specific) from the chart below will you will then get the total external static pressure or total system static pressure. Inlet Hood with Filters .25" W.C. Inlet Damper .13" W.C. Discharge Damper .15" W.C. V-bank filter Box .25" W.C. CEV .25” W.C. Cabinet .50” W.C. These are estimate values and may vary based on actual condition and CFM. ARES DIRECT FIRED MODEL 15 (15” x 15” DWDI FC) AIR REPLACEMENT ENGINEERED SYSTEMS 3.00 1300 2.50 1200 2.25 2.00 1100 (s) 2 1/ 7- 1.75 1000 900 Syste m 1.25 5 Curve 1.50 1.00 .75 3 External Static Pressure (In. W.G.) 2.75 800 2 1 .50 /2 1/ 2 3 H /4 1 .25 -1 700 RPM P .00 0 4 8 12 16 20 24 28 32 36 40 44 48 52 56 60 64 68 72 76 80 84 88 92 Volume (CFM - 00's omitted) ADF15-FC 11/19/03 TJ Performance curves based on tests made in accordance with A.M.C.A. 210-85. Tested with discharge duct. Horsepower does not include drive loses. Standard air density 0.075 Lb/Cu. Ft. External static pressure to unit and unit accessories (Inches W.C.). You must add the accessories static pressure losses to the ARES unit. (See chart below) The fan curve includes all internal loses and with your required unit accessories (Job specific) from the chart below will you will then get the total external static pressure or total system static pressure. Inlet Hood with Filters .25" W.C. Inlet Damper .13" W.C. Discharge Damper .15" W.C. V-bank filter Box .25" W.C. CEV .25” W.C. Cabinet .50” W.C These are estimated values and may vary based on actual condition and CFM. ARES DIRECT FIRED MODEL 20 (20” x 20” DWDI FC) AIR REPLACEMENT ENGINEERED SYSTEMS 3.00 2.50 900 2.25 850 15 2.00 800 1.75 (s) 750 Curve System 700 .75 650 /2 1.00 1 7- 1.25 10 1.50 600 5 External Static Pressure (In. W.G.) 2.75 3 550 .50 1 RPM H P /2 -1 1 .25 2 500 450 .00 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Volume (CFM - 000's omitted) ADF20-FC 11/19/03 TJ ARES A5-D.2500-925 DIRECT FIRED M.U.A. WITH V-BANK FILTERED INTAKE This Page is blank This Page is blank This Page is blank This Page is blank ARES DIRECT-FIRED ORDER WORKSHEET & TRANSMITTAL Date:___/___/___ Ref # __________ Invoice to: Address MODEL # Price BASE UNIT MOTOR ___ HP VOLTAGE ___/___/___ P.O. # Ship to: Address BURNER INPUT BTU'S ______________ Contact Name: CFM Elevation INDOOR / OUTDOOR Unit External Static Pressure: Inlet Hood w/ Birdscreen 0.13" W.C. Inlet Hood w/ Filters 0.25" W.C. V-Bank Filter Section 0.25" W.C. Discharge Damper 0.15" W.C. Inlet Damper 0.13" W.C. ______" W.C. System Duct Work TOTAL EXTERNAL STATIC PRESSURE Horse Power Voltage High Efficiency ODP (STD) T.E.F.C. Super Efficiency O.D.P. T.E.F.C. 115/1 208/1 230/1 208/3 230/3 460/3 6" 12" 2 -12" 3 - 12" w/ high gas pressure switch w/ low gas pressure switch w/ high & low gas pressure switch ACCESSORIES Inlet Hood w/Birdscreen w/ 1" Cleanable filters V-Bank Filter Section w/ 2" Cleanable filters w/ 2" Pleated Throwaway Dampers Inlet Motorized 2 Position Discharge Motorized 2 Position Insulation 1" Foil Face Indoor (burner and filter section) Outdoor (Blower Section) EVAP Cooling (CEV Only) Roof Curb Flat 14" High Non Canted Flat 24" High Non Canted Combo 14" with Exhaust Fan Exhaust Fan ID Inlet Air Temperature Outlet Air Temperature Temperature Rise 6-14" W.C. Normal Inlet Gas Pressure Required Input BTU's Natural Gas Propane Freeze Stat Mild Weather Lockout Exhaust Fan Interlock Standard/Included Standard/Included Standard/Included AGENTS SIGNATURE _______________________________ Date: ____/____/____ ____" x ____" ELECTRICAL OPTIONS Remote Control Station 7 Day/24 Hour Time Clock Clogged Filter Light & Switch Fused Disconnect Switch 600 Volt 300 Volt Convenience GFI Outlet Box Misc. Option Explain Interface Control Panel TOTAL LIST PRICE EACH (PER UNIT) DISCOUNT MULTIPLIER X TOTAL NET FREIGHT ESTIMATE