Product Literature

Transcription

Product Literature
Features
UHMW SHOE
GUIDE BAR
500 Ton 30 ft
Press Break >
SMOOTH SHIFT, INTERNAL
BYPASS CYLINDERS
DETAIL A
< Remote
Power
Unit
A
HYDRAULIC QUICK
DISCONNECTS
LIQUID WASTE TRAPPED BEHIND
THE PLATEN IS EASILY FLUSHED
UNDER THE COMPACTOR CHAMBER.
PLATEN FLOOR
HARDENED AR-PLATE
Ram Guide System
The Self-Contained cross cylinder ram features side mounted full
length Ultra-High Molecular Weight (UHMW) guides to support
the ram providing uncompromising longevity and reliability.
Door Protector >
Door Protector
Prevents roll-off hoist cable from contacting the door frame,
preventing bent doors and leaking seals.
< Door Latch w/Padlock Hasp
Lockable Door Latch
Hopper door can be locked preventing unauthorized usage.
Sub Floor Sump
Self-Contained Compactor sub floor is separated from the container
floor to form a tunnel to allow liquids to drain from behind the ram
when emptying.
Door Custom Fitted to Container >
Programmable Relay Controls
Self-Contained Compactors by Cram-A-Lot are designed to use a
readily available non-proprietary programmable relay.
Single Piece Side Sheet and Floor
Cram-A-lot’s manufacturing plant uses a 30 foot 500 ton press
break to form sides and floors allowing no vertical seems.
Rear Gate Hinge & Seal
Self-Contained Compactors have a full door seal and a 3 point door
latch that provides excellent compression and sealing properties.
< Catch Latch
Rust Inhibiting Primer
Self-Contained Compactors are primed with rust inhibiting red oxide
primer to reduce corrosion.
< Full Door Seal
All Cram-A-Lot compactors conform
to all current ANSI Z 245.2 safety standards
All information is subject to engineering
and/or other changes without notice.
Rust Inhibiting Primer
Remote
Controls
Color Coded
Pressure
Gauge
Hinged Breaker Bar Teeth
Key Operation
All compactors, come with on/off switch as mandated by
ANSI Z 245.2 safety standards. Cram-A-lot offers additional
options for increased levels of safety.
Color Coded Pressure Gauge
The color coded gauge indicates 50%, 75% and 100% fullness.
The gauge is more accurate then fullness lights.
Oil Heater
Ideal for cold climate areas. The oil heater automatically maintains
the oil at 70 degrees.
Oil Heater
Hinged Breaker Bar Teeth
Hinged breaker bar teeth hold trash in place, preventing trash from
springing back into the chamber.
Ozone Odor Neutralizer
Odor neutralizers like the Sonozaire circulate the ozone, permitting
it to search out and destroy odor molecules. The result is a
clean-smelling area, which does not harbor and protect bacteria
ending odor complaints and assuring customer satisfaction.
J.V. Manufacturing will furnish without charge:
Odor Neutralizer
Cram-A-Lot 1-2-3 Warranty
1) All parts and labor expenses through the first year of ownership to remedy any faults proven to be the result of defective materials or workmanship.
2) All parts through the second year of ownership to remedy any faults proven to be the result of defective materials or workmanship.
3) All labor expenses through the third year of ownership to remedy any structural faults proven to be the result of defective materials or workmanship.
This warranty does not apply to any damage caused by negligence, misuse, modifications, alterations, or accidents by purchaser or third parties.
Refer to operation manual for specific warranty coverage.
Standard and Special Applications
Hydraulic Tailgate
Integral Rear Feed
Cart Dumper
Walk-On
Full Enclosure
Side Load
Through-The-Wall
Break-A-Way Hopper
Rear Load
Through-The-Wall
Break-A-Way Hopper
ELECTRICAL FEATURES ON ALL MODELS
UL Listed Control Panel
Only Major Brand Electrical Components Used
Weather Tight Electrical Enclosure
C
B
ONE YARD
SELF-CONTAINED COMPACTOR
Specifications SC-T1-1 0/15/20 SC-T1-1 6/20/25-H TG
Char ge B ox Capac ity
W ASTEC Rating
Clea r To p Op enin g
Th eore tical Cy cle Ti me
To tal F orce
Ra m F ac e Pre ss ure
1 Cu Yd
0.75 Cu Yd
31"
28 Sec
Normal
Max imum
Normal
Max imum
Ra m F ac e Dim ension s, W X H
Ra m Penetra tion
Moto r - 3Phase - 20 8/230/460 Vac
Pum p Ca pacity
Hyd ra ulic Res er voir Capac ity
B ore Dia.
Hyd ra ulic Cy linder
Stroke
Rod Dia.
Normal
Op er ating Pres sure
Max imum
DIMENSIONS
SC-T1-1 0
SC-T1-1 5
SC-T1-2 0
SC-T1-1 6-H TG
SC-T1-2 0-H TG
1 Cu Yd
0.75 Cu Yd
31"
28 Sec
42,700 Ibs
42,700 Ibs
51,200 Ibs
51,200 Ibs
38.7 Psi
38.7 Psi
46.4 Psi
46.4 Psi
48" x 23"
48" x 23"
6"
10 Hp
6"
10 Hp
10.5 Gpm
10.5 Gpm
22 gal
22 gal
Two, 4"
Two, 4"
26"
26"
2"
2000 Psi
2"
2000 Psi
2400 Psi
2400 Psi
(A )
OVER
ALL
LENGT H
13' - 2"
16' - 6"
19' - 10"
(B )
CLEA R
TO P
LENGT H
31"
31"
31"
(C)
PA CK ER
LENGT H
60"
60"
60"
B ASE
UN IT
W EIG H
6,500 lbs
7,000 Ibs
7,500 Ibs
NORMAL
CONTA INER
CAPA CITY
10 CU YD
15 CU YD
20 CU YD
18'
19' 8"
31"
31"
60"
60"
8,000 Ibs
8,200 Ibs
16 CU YD
20 CU YD
C
B
** Above drawings are shown with universal understructures. **
Self-Contained Compactors Units can be custom designed and factory installed to
suit your special applications
ELECTRICAL FEATURES ON ALL MODELS
UL Listed Control Panel
Only Major Brand Electrical Components Used
Weather Tight Electrical Enclosure
T WO Y ARD SELF -CONT AINED COMP
Specif ications
Char ge B ox Capac ity
W ASTEC Rating
Clea r To p Op enin g
Th eore tical Cy cle Ti me
To tal F orce
Ra m F ac e Pre ss ure
Normal
Max imum
Normal
Max imum
Ra m F ac e Dim ension s, W X H
Ra m Penetra tion
Moto r - 3Phase - 20 8/230/460 Vac
Pum p Ca pacity
Hyd ra ulic Res er voir Capac ity
Hyd ra ulic Cy linder
B ore Dia.
Stroke
Rod Dia.
Op er ating Pres sure
DIMENSIONS
Normal
Max imum
SC-T2-2 0/25/30/34/38
2 Cubic Yard
1.52
41" x 58"
37 Sec
42,700 Ibs
51,250 Ibs
24.5 Psi
29.5 Psi
60" x 29"
8"
10 Hp
10.5 Gpm
SC-0 2-2 0/25/30/34
2 Cubic Yard
1.31
34" x 58"
32 Sec
39,300 Ibs
47,100 Ibs
22.6 Psi
27.1 Psi
60" x 29"
5.5"
10 Hp
10.5 Gpm
SC-T2-2 0/25/30/34-HTG
2 Cubic Yard
1.52
41" x 58"
37 Sec
42,700 Ibs
51,250 Ibs
24.5 Psi
29.5 Psi
60" x 29"
8"
10 Hp
10.5 Gpm
22 GAL
Two - 4"
34"
2"
2000 Psi
2400 Psi
22 Gal
5"
40"
3"
2000 Psi
2400 Psi
22 Gal
Two - 4"
34"
2"
2000 Psi
2400 Psi
(A )
(B )
(C)
OVER
ALL
LENGT H
17' 4 "
19' - 11"
22' - 1"
23' 9"
25' - 10"
CLEA R
TO P
LENGT H
41"
41"
41"
41"
41"
PA CK ER
LENGT H
71"
71"
71"
71"
71"
B ASE
UN IT
W EIG HT
9800 Ibs
10,000 Ibs
10,800 Ibs
10,900 Ibs
12,000 Ibs
NORMAL
CONTA INER
CAPA CITY
20 CU YD
25 CU YD
30 CU YD
34 CU YD
38 CU YD
2-2 0
2-2 5
2-3 0
2-3 4
19'
21' - 7"
23' - 9"
25' - 5"
34"
34"
34"
34"
90 1/2"
90 1/2"
90 1/2"
90 1/2"
9,860 Ibs
10,100 Ibs
10,800 Ibs
10,900 Ibs
20 CU YD
25 CU YD
30 CU YD
34 CU YD
SC-T2-2 0-H TG
SC-T2-2 5-H TG
SC-T2-3 0-H TG
17'
19' - 8"
21' 9"
41"
41"
41"
71"
71"
71"
10,260 Ibs
10,900 Ibs
11,540 Ibs
20 CU YD
25 CU YD
30 CU YD
SC-T2-2
SC-T2-2
SC-T2-3
SC-T2-3
SC-T2-3
SC-0
SC-0
SC-0
SC-0
0
5
0
4
8
ACT OR
** Above drawings are shown with universal understructures. **