Product Literature
Transcription
Product Literature
Features UHMW SHOE GUIDE BAR 500 Ton 30 ft Press Break > SMOOTH SHIFT, INTERNAL BYPASS CYLINDERS DETAIL A < Remote Power Unit A HYDRAULIC QUICK DISCONNECTS LIQUID WASTE TRAPPED BEHIND THE PLATEN IS EASILY FLUSHED UNDER THE COMPACTOR CHAMBER. PLATEN FLOOR HARDENED AR-PLATE Ram Guide System The Self-Contained cross cylinder ram features side mounted full length Ultra-High Molecular Weight (UHMW) guides to support the ram providing uncompromising longevity and reliability. Door Protector > Door Protector Prevents roll-off hoist cable from contacting the door frame, preventing bent doors and leaking seals. < Door Latch w/Padlock Hasp Lockable Door Latch Hopper door can be locked preventing unauthorized usage. Sub Floor Sump Self-Contained Compactor sub floor is separated from the container floor to form a tunnel to allow liquids to drain from behind the ram when emptying. Door Custom Fitted to Container > Programmable Relay Controls Self-Contained Compactors by Cram-A-Lot are designed to use a readily available non-proprietary programmable relay. Single Piece Side Sheet and Floor Cram-A-lot’s manufacturing plant uses a 30 foot 500 ton press break to form sides and floors allowing no vertical seems. Rear Gate Hinge & Seal Self-Contained Compactors have a full door seal and a 3 point door latch that provides excellent compression and sealing properties. < Catch Latch Rust Inhibiting Primer Self-Contained Compactors are primed with rust inhibiting red oxide primer to reduce corrosion. < Full Door Seal All Cram-A-Lot compactors conform to all current ANSI Z 245.2 safety standards All information is subject to engineering and/or other changes without notice. Rust Inhibiting Primer Remote Controls Color Coded Pressure Gauge Hinged Breaker Bar Teeth Key Operation All compactors, come with on/off switch as mandated by ANSI Z 245.2 safety standards. Cram-A-lot offers additional options for increased levels of safety. Color Coded Pressure Gauge The color coded gauge indicates 50%, 75% and 100% fullness. The gauge is more accurate then fullness lights. Oil Heater Ideal for cold climate areas. The oil heater automatically maintains the oil at 70 degrees. Oil Heater Hinged Breaker Bar Teeth Hinged breaker bar teeth hold trash in place, preventing trash from springing back into the chamber. Ozone Odor Neutralizer Odor neutralizers like the Sonozaire circulate the ozone, permitting it to search out and destroy odor molecules. The result is a clean-smelling area, which does not harbor and protect bacteria ending odor complaints and assuring customer satisfaction. J.V. Manufacturing will furnish without charge: Odor Neutralizer Cram-A-Lot 1-2-3 Warranty 1) All parts and labor expenses through the first year of ownership to remedy any faults proven to be the result of defective materials or workmanship. 2) All parts through the second year of ownership to remedy any faults proven to be the result of defective materials or workmanship. 3) All labor expenses through the third year of ownership to remedy any structural faults proven to be the result of defective materials or workmanship. This warranty does not apply to any damage caused by negligence, misuse, modifications, alterations, or accidents by purchaser or third parties. Refer to operation manual for specific warranty coverage. Standard and Special Applications Hydraulic Tailgate Integral Rear Feed Cart Dumper Walk-On Full Enclosure Side Load Through-The-Wall Break-A-Way Hopper Rear Load Through-The-Wall Break-A-Way Hopper ELECTRICAL FEATURES ON ALL MODELS UL Listed Control Panel Only Major Brand Electrical Components Used Weather Tight Electrical Enclosure C B ONE YARD SELF-CONTAINED COMPACTOR Specifications SC-T1-1 0/15/20 SC-T1-1 6/20/25-H TG Char ge B ox Capac ity W ASTEC Rating Clea r To p Op enin g Th eore tical Cy cle Ti me To tal F orce Ra m F ac e Pre ss ure 1 Cu Yd 0.75 Cu Yd 31" 28 Sec Normal Max imum Normal Max imum Ra m F ac e Dim ension s, W X H Ra m Penetra tion Moto r - 3Phase - 20 8/230/460 Vac Pum p Ca pacity Hyd ra ulic Res er voir Capac ity B ore Dia. Hyd ra ulic Cy linder Stroke Rod Dia. Normal Op er ating Pres sure Max imum DIMENSIONS SC-T1-1 0 SC-T1-1 5 SC-T1-2 0 SC-T1-1 6-H TG SC-T1-2 0-H TG 1 Cu Yd 0.75 Cu Yd 31" 28 Sec 42,700 Ibs 42,700 Ibs 51,200 Ibs 51,200 Ibs 38.7 Psi 38.7 Psi 46.4 Psi 46.4 Psi 48" x 23" 48" x 23" 6" 10 Hp 6" 10 Hp 10.5 Gpm 10.5 Gpm 22 gal 22 gal Two, 4" Two, 4" 26" 26" 2" 2000 Psi 2" 2000 Psi 2400 Psi 2400 Psi (A ) OVER ALL LENGT H 13' - 2" 16' - 6" 19' - 10" (B ) CLEA R TO P LENGT H 31" 31" 31" (C) PA CK ER LENGT H 60" 60" 60" B ASE UN IT W EIG H 6,500 lbs 7,000 Ibs 7,500 Ibs NORMAL CONTA INER CAPA CITY 10 CU YD 15 CU YD 20 CU YD 18' 19' 8" 31" 31" 60" 60" 8,000 Ibs 8,200 Ibs 16 CU YD 20 CU YD C B ** Above drawings are shown with universal understructures. ** Self-Contained Compactors Units can be custom designed and factory installed to suit your special applications ELECTRICAL FEATURES ON ALL MODELS UL Listed Control Panel Only Major Brand Electrical Components Used Weather Tight Electrical Enclosure T WO Y ARD SELF -CONT AINED COMP Specif ications Char ge B ox Capac ity W ASTEC Rating Clea r To p Op enin g Th eore tical Cy cle Ti me To tal F orce Ra m F ac e Pre ss ure Normal Max imum Normal Max imum Ra m F ac e Dim ension s, W X H Ra m Penetra tion Moto r - 3Phase - 20 8/230/460 Vac Pum p Ca pacity Hyd ra ulic Res er voir Capac ity Hyd ra ulic Cy linder B ore Dia. Stroke Rod Dia. Op er ating Pres sure DIMENSIONS Normal Max imum SC-T2-2 0/25/30/34/38 2 Cubic Yard 1.52 41" x 58" 37 Sec 42,700 Ibs 51,250 Ibs 24.5 Psi 29.5 Psi 60" x 29" 8" 10 Hp 10.5 Gpm SC-0 2-2 0/25/30/34 2 Cubic Yard 1.31 34" x 58" 32 Sec 39,300 Ibs 47,100 Ibs 22.6 Psi 27.1 Psi 60" x 29" 5.5" 10 Hp 10.5 Gpm SC-T2-2 0/25/30/34-HTG 2 Cubic Yard 1.52 41" x 58" 37 Sec 42,700 Ibs 51,250 Ibs 24.5 Psi 29.5 Psi 60" x 29" 8" 10 Hp 10.5 Gpm 22 GAL Two - 4" 34" 2" 2000 Psi 2400 Psi 22 Gal 5" 40" 3" 2000 Psi 2400 Psi 22 Gal Two - 4" 34" 2" 2000 Psi 2400 Psi (A ) (B ) (C) OVER ALL LENGT H 17' 4 " 19' - 11" 22' - 1" 23' 9" 25' - 10" CLEA R TO P LENGT H 41" 41" 41" 41" 41" PA CK ER LENGT H 71" 71" 71" 71" 71" B ASE UN IT W EIG HT 9800 Ibs 10,000 Ibs 10,800 Ibs 10,900 Ibs 12,000 Ibs NORMAL CONTA INER CAPA CITY 20 CU YD 25 CU YD 30 CU YD 34 CU YD 38 CU YD 2-2 0 2-2 5 2-3 0 2-3 4 19' 21' - 7" 23' - 9" 25' - 5" 34" 34" 34" 34" 90 1/2" 90 1/2" 90 1/2" 90 1/2" 9,860 Ibs 10,100 Ibs 10,800 Ibs 10,900 Ibs 20 CU YD 25 CU YD 30 CU YD 34 CU YD SC-T2-2 0-H TG SC-T2-2 5-H TG SC-T2-3 0-H TG 17' 19' - 8" 21' 9" 41" 41" 41" 71" 71" 71" 10,260 Ibs 10,900 Ibs 11,540 Ibs 20 CU YD 25 CU YD 30 CU YD SC-T2-2 SC-T2-2 SC-T2-3 SC-T2-3 SC-T2-3 SC-0 SC-0 SC-0 SC-0 0 5 0 4 8 ACT OR ** Above drawings are shown with universal understructures. **