Federal Rowco Brochure
Transcription
Federal Rowco Brochure
Federal/Rowco . . . Heavy Duty Industrial Switchgear Solutions Built to Last Heavy Duty The FEDERAL & ROWCO range uses diecast aluminium exteriors that offer excellent impact resistance, ensuring long product life, indoors or outdoors. The materials used are proven to operate in extreme temperatures from –20oC to +60oC ambient. FEDERAL & ROWCO products have been in the field for decades, with a reputation for performance excellence in harsh environments. Use FEDERAL & ROWCO where you need a product that can take a beating or withstand high temperatures without compromising performance or safety. Switch status information is cast onto product to ensure it is visible even in the harshest of conditions. Both FEDERAL and ROWCO products are made from high quality aluminium, providing you a lightweight, corrosion resistant product suitable for demanding industrial applications, where safety and durability is a priority. IP Rating FEDERAL and ROWCO are true heavy duty industrial solutions. FEDERAL & ROWCO products are rated to IP66. FEDERAL & ROWCO synthetic gaskets provide high performance protection in all situations for peace of mind. Rigorous Testing FEDERAL switches are the most versatile available. Besides testing to AS3133, FEDERAL switches have been tested to EN60947-3, providing several specialist ratings specific to certain applications. This means that a FEDERAL switch can be matched directly and accurately to an application, providing confidence to specifiers and end-users. All FEDERAL one-way switches are Switch Disconnectors, meaning they are suitable for use as isolating switches. Modular Design Based upon 3 frame sizes, the FEDERAL & ROWCO range has been designed as a family of products, allowing interchangeability. This means that junction / utility boxes can be mounted and with only a cover change, can be turned into a switch or switched socket outlet. Besides ensuring versatility, the vigorous testing regime undertaken by FEDERAL switches is testament to the superior quality of the product offer. This superiority translates to less equipment downtime and improved safety in the workplace, both issues of great importance to business managers and their technical experts. The same high-performance switches used in FEDERAL are also used in all ROWCO switched socket outlets. Page 2 Safety in action Easy installation ROWCO switched socket outlets have been designed for safety. All single phase products feature double pole switching and all three phase products feature an interlock mechanism between switch and socket. This prevents the insertion or withdrawal of plugtops when the switch is in the ON position. FEDERAL and ROWCO products were designed with installers in mind. All products can be mounted using internal or external options, depending on what the application requires. This flexibility extends to the earthing point - these can be relocated within the enclosure to suit on-site requirements. All switches can be padlocked off in two locations. Each of these two padlock positions can accept an 8mm hasp padlock or a scissor lockout tag. This feature supports important occupational health and safety procedures employed throughout industry. All larger switches in the FEDERAL range are base mounted, in recognition of the large cable sizes used in these applications. Through this we support simpler and faster installation. All products are supplied with stainless steel cover screws. These screws offer excellent noncorrosive properties and are treated to prevent chemical reaction with the aluminium castings. These cover screws are standard metric thread, so alternatives can be easily arranged should the need arise. All conduit entry points and rear cut-out guides are metric for familiarity and ease of use. FEDERAL Metal Isolator Switches Size 1 1 Pole Size 2 Size 3 20A 32A 20A 32A 40A 50A 63A 80A 4 Pole 20A 32A 40A 50A 63A 80A 6 Pole 20A 32A 3 Pole 7 Pole 16A 63A 32A FEDERAL Metal Changeover Switches FEDERAL Metal Forward / Reverse Switches Page 3 100A 125A FEDERAL Metal Isolator Switches • • • FEDERAL Metal Isolator Switches • • • Page 4 14 Frame Size 1 1 Pole – 4 Pole 20A – 32A FEDERAL Metal Changeover and Forward / Reverse Switches • • • 12 Frame Size 3 3 Pole – 6 Pole 63A – 125A FEDERAL Metal Changeover and Forward / Reverse Switches • • • 8 Frame Size 2 3 Pole – 7 Pole 20A – 63A FEDERAL Metal Isolator Switches • • • 6 Frame Size 1 1 Pole – 4 Pole 16A – 32A Frame Size 2 & Frame Size 3 3 Pole - 4 Pole 32A - 63A 16 Contents FEDERAL Metal Retrofit Isolator Switches • • • Frame Size A & B 3 Pole – 4 Pole 20A – 32A ROWCO Metal Switched Socket Outlets • • • 26 3 Pin – 7 Pin 10A – 50A VARIO Add-on Auxiliary Contacts Page 5 24 Frame Size 1 & 2 MATRIX Straight and Angled Plugs • • 20 Frame Size 2 3 Pin – 7 Pin 10A – 50A ROWCO Junction Boxes • 18 28 FEDERAL Metal Isolator Switches - IP66 Dimensional Drawings WR320M Frame Size 1 Feature: A range of top-performing switches built to handle heavy duty environments. FEDERAL isolator switches are industry leaders, in terms of versatility, range and ease of installation. • • • • • • • • • All switches meet the requirements of isolation required by AS3000:2000 and are classified as Switch Disconnectors under AS3947-3. 1 - 4 pole switches up to 32A Cover mounted switch mechanisms Comprehensive switching ratings IP66 weather protection rating Dual padlocking points Multiple earthing points Multiple mounting options Long-life synthetic gasket Earth bonding wire from cover to base supplied with each product as standard All versions feature ease of installation benefits, multiple ratings for versatility and have been designed to ensure user safety. Wiring Diagrams Page 6 A Single Pole, Single Throw B Triple Pole, Single Throw C Four Pole, Single Throw FEDERAL Metal Isolator Switches - IP66 Cat No WR120M WR132M WR316M WR320M WR332M WR420M WR432M Volts 240 240 415 415 415 415 415 Volts 660 660 660 660 660 690 690 2.5 2.5 2.5 2.5 2.5 6 6 20 32 20 32 Rated Operational Voltage Ue (~50Hz) Rated Insulation Voltage Ui (~50Hz) Rated Impulse Withstand Voltage Uimp (~50Hz) kV Rated Thermal Current Enclosed 20 32 16 Rated Duty Amps Uninterrupted Uninterrupted Uninterrupted Uninterrupted Uninterrupted Uninterrupted Uninterrupted Description Single Single 3 Pole 3 Pole 3 Pole 4 Pole 4 Pole Pole Pole Wiring Diagram A A B B B C C Frame Size Size 1 Size 1 Size 1 Size 1 Size 1 Size 1 Size 1 Switch Mounting Type Cover Cover Cover Cover Cover Cover Cover Mount Mount Mount Mount Mount Mount Mount Cable Cross Sections Min (mm2) 1 1 1 1 1 1 1 Max (mm2) 16 16 16 16 16 10 10 0.4pf Inductive 20AX 32AX - - - - - 415V M Rating M150 M180 M120 M150 M180 - - Solid or Standard Switch Rating @ AS3133 Switch Rating @ EN60947-3 AC21A 415V AC23A 240/415V Amps 20 32 16 20 32 20 32 3 4 7.5 11 15 7.5 11 21 28 15 21 28 14 21 2.2 3 5.5 7.5 11 5.5 7.5 Amps 15 21 11 15 21 11 14 Amps - - 16 20 32 - - 1500 1500 1500 1500 300 384 1 1 1 1 1 1 kW Amps AC3 240/415V DC21A 32V kW Rated Short Time Withstand CurrentAmps/1 second 1500 Rated Short Circuit Making Capacity kAp 1 NOTES: AC21A Switch of AC Resistive loads, including moderate overloads. AC23A Switch of motor loads or other highly inductive loads. AC3 Squirrel-cage motors: starting, switching motors off during running. DC21A Switch of DC Resistive loads, including moderate overloads. Page 7 FEDERAL Metal Isolator Switches - IP66 Dimensional Drawings WR632M Frame Size 2 Feature: A range of top-performing switches built to handle heavy duty environments. FEDERAL isolator switches are industry leaders, in terms of versatility, range and ease of installation. • • • All switches meet the requirements of isolation required by AS3000:2000 and are classified as Switch Disconnectors under AS3947-3. All versions feature ease of installation benefits, multiple ratings for versatility and have been designed to ensure user safety. • • • • • • • • Up to 7 pole 32A switches Up to 4 pole 63A switches Base mounted switch mechanisms - with safety interlock Comprehensive switching ratings IP66 weather protection rating Dual padlocking points Multiple earthing points Multiple mounting options Long-life synthetic gasket Earth bonding wire from cover to base supplied with each product as standard Circuit or product ID recess All switches are base mounted, with safety interlock to ensure cover cannot be removed with switch in the on position. Page 8 FEDERAL Metal Isolator Switches - IP66 Wiring Diagrams Cat No WR340M WR350M WR363M WR440M Volts 415 415 415 415 Volts 660 690 690 690 kV 2.5 2.5 6 6 40 Rated Operational Voltage Ue (~50Hz) Rated Insulation Voltage Ui (~50Hz) B Triple Pole, Single Throw Rated Impulse Withstand Voltage Uimp (~50Hz) Rated Thermal Current Enclosed Amps C Four Pole, Single Throw 40 50 63 Rated Duty Uninterrupted Uninterrupted Uninterrupted Uninterrupted Description 3 Pole 3 Pole 3 Pole 4 Pole C Wiring Diagram B B B Frame Size Size 2 Size 2 Size 2 Size 2 Switch Mounting Type Cover Mount Base Mount Base Mount Base Mount Min (mm2) 6 6 2.5 1 Max (mm2) 35 35 25 10 Cable Cross Sections Solid or Standard Switch Rating @ AS3133 0.4pf Inductive - - - - 415V M Rating M200 M250 - - Switch Rating @ EN60947-3 AC21A 415V Amps AC23A 240/415V kW AC3 240/415V DC21A 32V 40 50 63 40 18.5 18.5 22 15 Amps 35 35 40 28 kW 15 15 18.5 11 Amps 28 28 35 21 Amps 40 50 - - 2500 1500 756 480 2.5 2.1 2.1 1 - 1 1 - Rated Short Time Withstand Current Amps/1 second Rated Short Circuit Making Capacity kAp Maximum number of Add-on Auxiliary Contact Module See VARIO Add-on Auxiliary Contact on page 28 for further information. Page 9 FEDERAL Metal Isolator Switches - IP66 Cat No WR450M WR463M WR620M WR632M WR732M Volts 415 415 415 415 415 Volts 690 690 690 690 690 6 6 6 6 6 50 63 20 32 32 Rated Duty Uninterrupted Uninterrupted Uninterrupted Uninterrupted Uninterrupted Description 4 Pole 4 Pole 6 Pole 6 Pole 7 Pole Wiring Diagram C C D D E Frame Size Size 2 Size 2 Size 2 Size 2 Size 2 Switch Mounting Type Base Mount Base Mount Base Mount Base Mount Base Mount Min (mm2) 2.5 2.5 1 1 1 Max (mm2) 25 25 10 10 10 Rated Operational Voltage Ue (~50Hz) Wiring Diagrams Rated Insulation Voltage Ui (~50Hz) Rated Impulse Withstand Voltage Uimp (~50Hz) kV Rated Thermal Current Enclosed Amps C Four Pole, Single Throw D Six Pole, Single Throw Cable Cross Sections Solid or Standard Switch Rating @ AS3133 0.4pf Inductive - - - - - 415V M Rating - - - - - Switch Rating @ EN60947-3 AC21A 415V AC23A 240/415V AC3 240/415V DC21A 32V Amps 50 63 20 32 32 kW 22 22 7.5 11 11 Amps 40 40 14 21 21 18.5 18.5 5.5 7.5 7.5 Amps 35 35 11 14 14 Amps - - - - - Amps/1 second 756 756 300 384 384 kAp 2.1 2.1 1 1 1 kW Rated Short Time Withstand Current Rated Short Circuit Making Capacity Page 10 E Seven Pole, Single Throw Page 11 FEDERAL Metal Isolator Switches - IP66 Dimensional Drawings WR3125M Frame Size 3 Feature: A range of top-performing switches built to handle heavy duty environments. FEDERAL isolator switches are industry leaders, in terms of versatility, range and ease of installation. • • • • • • • • • • • All switches meet the requirements of isolation required by AS3000:2000 and are classified as Switch Disconnectors under AS3947-3. All versions feature ease of installation benefits, multiple ratings for versatility and have been designed to ensure user safety. • Up to 3 pole 125A switches Up to 4 pole 80A switches Up to 6 pole 63A switches Base mounted switch mechanisms Comprehensive switching ratings IP66 weather protection rating Dual padlocking points Multiple earthing points Multiple mounting options Long-life synthetic gasket Earth bonding wire from cover to base supplied with each product as standard Circuit or product ID recess All switches are base mounted, with safety interlock to ensure cover cannot be removed with switch in the on position. Page 12 FEDERAL Metal Isolator Switches - IP66 Wiring Diagrams Cat No WR380M WR3100M WR3125M WR480M WR663M Volts 415 415 415 415 415 Volts 690 690 690 690 690 6 6 6 6 6 Rated Operational Voltage Ue (~50Hz) Rated Insulation Voltage Ui (~50Hz) Rated Impulse Withstand Voltage Triple Pole, Single Throw B Uimp (~50Hz) kV Rated Thermal Current Enclosed Amps Four Pole, Single Throw C 80 100 125 80 63 Rated Duty Uninterrupted Uninterrupted Uninterrupted Uninterrupted Uninterrupted Description 3 Pole 3 Pole 3 Pole 4 Pole 6 Pole Wiring Diagram B B B C D Frame Size Size 3 Size 3 Size 3 Size 3 Size 3 Switch Mounting Type Base Mount Base Mount Base Mount Base Mount Base Mount Min (mm2) 2.5 10 10 2.5 2.5 Max (mm2) 25 95 95 25 25 0.4pf Inductive - - - - - 415V M Rating - - - - - Cable Cross Sections Solid or Standard Switch Rating @ AS3133 Switch Rating @ EN60947-3 Six Pole, Single Throw D AC21A 415V AC23A 240/415V AC3 240/415V Amps 80 100 125 80 63 kW 30 37 37 30 22 Amps 55 66 66 55 40 kW 22 30 30 22 18.5 Amps 40 55 55 40 35 Amps - - - - - Amps/1 second 960 1500 1500 960 756 kAp 2.1 2.8 2.8 2.1 2.1 1 2 2 2 1 DC21A 32V Rated Short Time Withstand Current Rated Short Circuit Making Capacity Maximum Number of Add-on Auxiliary Contact Module See VARIO Add-on Auxiliary Contact on page 28 for further information. NOTES: AC21A Switch of AC Resistive loads, including moderate overloads. AC23A Switch of motor loads or other highly inductive loads. AC3 Squirrel-cage motors: starting, switching motors off during running. DC21A Switch of DC Resistive loads, including moderate overloads. Page 13 FEDERAL Metal Changeover and Forward/Reverse Switches – IP66 Dimensional Drawings Frame Size 1 WRC320M Frame Size 1 A range of changeover and forward / reverse switches suited for harsh industrial environments. With comprehensive motor ratings, these switches are ready for heavy duty applications. All versions feature ease of installation benefits, multiple ratings for versatility and have been designed to ensure user safety. Feature: • Comprehensive motor ratings for each model • Heavy duty performance • IP66 weather protection rating • Dual padlocking points • Multiple earthing points • Multiple mounting options • Long-life synthetic gasket • Earth bonding wire from cover to base supplied with each product as standard • Circuit or product ID recess Changeover Switches • 1 & 3 pole, 20A & 32A ratings • Cover mounted switch mechanisms Reversing Switches • 3 pole at 20A & 32A rating • Cover mounted mechanism Page 14 FEDERAL Metal Changeover and Forward/Reverse Switches – IP66 Wiring Diagrams Cat No WRC120M WRC132M WRC320M WRC332M WRC420M Volts 240 240 415 415 415 Amps Rated Operational Voltage Ue (~50Hz) Rated Thermal Single Pole Changeover Switch, Double Throw with Centre off A Current Enclosed 20 32 20 32 20 Wiring Diagram A A B B C Description 1 Pole 1 Pole 3 Pole 3 Pole 4 Pole Changeover Changeover Changeover Changeover Changeover Size 1 Size 1 Size 1 Size 1 Size 1 2 x 2.5 2x6 2 x 2.5 2x6 2 x 2.5 - Frame Size Cable Cross Sections mm2 Solid or Standard Switch Rating @ EN60947-3 Triple Pole Changeover Switch, Double Throw with Centre Off B AC21A 415V, 1 Phase Amps 20A 32A - - 3 Phase Amps - - 20 32 20 AC23A 415V, 3 Phase kW - - 7.5 15 7.5 Amps AC23A 240V, 1 Phase kW Amps AC3 415V, 3 Phase AC3 240V, 1 Phase - - 15 28 15 2.5 7.5 - - - 15 26 - - - kW - - 5.5 11 5.5 Amps - - 11 21 11 2.2 - - - - - - - - - 140 480 140 480 140 kW Amps Rated Short Circuit Time Withstand Current Four Pole Changeover Switch, Double Throw with Centre Off C Amps/1 second Cat No WRR320M WRR332M Volts 415 415 Amps Rated Operational Voltage Ue (~50Hz) Rated Thermal Current Enclosed 20 32 Wiring Diagram D D Description 3 Pole 3 Pole Frame Size Reversing Reversing Size 1 Size 1 2 x 2.5 2x6 Cable Cross Sections mm2 Solid or Standard Switch Rating @ EN60947-3 AC21A 415V, 1 Phase Amps - - 3 Phase Amps 20 32 7.5 15 AC23A 415V, 3 Phase kW Amps AC3 415V, 3 Phase kW Amps 15 28 5.5 11 11 21 140 480 Rated Short Circuit Time Withstand Current Amps/1 second D NOTES: AC21A Switch of AC Resistive loads, including moderate overloads. AC23A Switch of motor loads or other highly inductive loads. AC3 Squirrel-cage motors: starting, switching motors off during running. Page 15 FEDERAL Metal Changeover and Forward/Reverse Switches – IP66 Dimensional Drawings Frame Size 2 WRC432M Frame Size 2 & Frame Size 3 A range of changeover and forward / reverse switches suited for harsh industrial environments. With comprehensive motor ratings, these switches are ready for heavy duty applications. All versions feature ease of installation benefits, multiple ratings for versatility and have been designed to ensure user safety. Feature: • • • • • • • • • Comprehensive motor ratings for each model Heavy duty performance IP66 weather protection rating Dual padlocking points Multiple earthing points Multiple mounting options Long-life synthetic gasket Earth bonding wire from cover to base supplied with each product as standard Circuit or product ID recess Changeover switches • • 4 pole at 32A and 3 pole at 63A ratings Cover mounted (32A) and Base mounted (63A) switch mechanisms Reversing switches • • 3 pole at 63A ratings Base mounted (63A) switch mechanisms Page 16 Frame Size 3 FEDERAL Metal Changeover and Forward/Reverse Switches – IP66 Wiring Diagrams Cat No WRC432M Rated Operational Voltage Ue (~50Hz) Volts 415 Amps 32 Rated Thermal Current Enclosed Wiring Diagram C Description 4 Pole Frame Size Size 2 Changeover Cable Cross Sections Triple Pole Changeover Switch, Double Throw with Centre Off B mm2 Solid or Standard 2x6 Switch Rating @ EN60947-3 AC21A 415V, 1 Phase Amps 3 Phase Amps 32 AC23A 415V, 3 Phase kW 15 Amps 28 AC3 415V, 3 Phase - kW 11 Amps 21 Rated Short Circuit Time Withstand Current Amps/1 second 480 480 Four Pole Changeover Switch, Double Throw with Centre Off C Cat No WRC363M WRR363M Volts 415 415 Amps 63 63 Rated Operational Voltage Ue (~50Hz) Rated Thermal Current Enclosed Wiring Diagram B E Description 3 Pole 3 Pole Changeover Reversing Frame Size Size 3 Size 3 2 x 16 2 x 16 - E Cable Cross Sections mm2 Solid or Standard Switch Rating @ EN60947-3 AC21A 415V, 1 Phase Amps - 3 Phase Amps 63 63 AC23A 415V, 3 Phase kW 30 30 Amps 55 55 18.5 18.5 35 35 1000 1000 AC3 415V, 3 Phase kW Amps Rated Short Circuit Time Withstand Current Amps/1 second NOTES: AC21A Switch of AC Resistive loads, including moderate overloads. AC23A Switch of motor loads or other highly inductive loads. AC3 Squirrel-cage motors: starting, switching motors off during running. Page 17 FEDERAL Metal Retrofit Isolator Switches - IP56 Dimensional Drawings Frame Size A WR432RFM Frame size A & B Feature: A range of isolators designed to install onto existing enclosures for simplified maintenance. • To support existing installations into the future, these switches offer the variety of ratings available on standard FEDERAL isolators. • • • • • • • Comprehensive motor ratings for each model Heavy duty performance IP56 weather protection rating Dual padlocking points Supplied without base Long-life synthetic gasket Earth bonding wire from cover to base supplied with each product as standard Circuit or product ID recess Page 18 Frame Size B FEDERAL Metal Retrofit Isolator Switches - IP56 Wiring Diagrams Cat No WR320RFM WR332RFM WR432RFM* Volts 415 415 415 Volts 690 690 690 6 6 6 20 32 32 Rated Operational Voltage Ue (~50Hz) Rated Insulation Voltage Ui (~50Hz) Rated Impulse Withstand Voltage Triple Pole, Single Throw B Uimp (~50Hz) kV Rated Thermal Current Enclosed Amps Four Pole, Single Throw C Rated Duty Uninterrupted Uninterrupted Uninterrupted Description 3 Pole 3 Pole Wiring Diagram B B C Frame Size Size A Size B Size B Switch Mounting Type Base Mount Base Mount Base Mount Min (mm2) 1 1 1 Max (mm2) 10 10 10 25 32 32 5.5 5.5 - 20 20 - 7.5 11 11 14 21 21 4 4 - 14 14 - 4 Pole Cable Cross Sections Solid or Standard Switch Rating @ EN60947-3 AC21A 415V Amps AC23A 240V kW Amps AC23A 415V kW Amps AC3 240V kW Amps AC3 415V kW Amps 5.5 7.5 7.5 11 14 14 300 384 384 1 1 1 IP 56 IP 56 IP 56 Rated Short Time Withstand Current Amps/1 second Rated Short Circuit Making Capacity kAp IP Rating Correspond to the old version of the Federal Switch. * Can be used to replace old WR420M and WR435M covers or switch mechanisms NOTES: AC21A Switch of AC Resistive loads, including moderate overloads. AC23A Switch of motor loads or other highly inductive loads. AC3 Squirrel-cage motors: starting, switching motors off during running. DC21A Switch of DC Resistive loads, including moderate overloads. Page 19 ROWCO Metal Switched Socket Outlets - IP66 Dimensional Drawings RC550M Frame Size 2 A range of heavy duty switched socket outlets designed for top performance in harsh industrial environments. Feature: Comprehensive switch ratings, including motor ratings, are standard across all products. • Safety is a key feature across the range, with double pole switching on single phase product and an interlocking mechanism between switch and socket on three phase products, as standard. • • • • • • • • One piece combinations Comprehensive switch ratings, including motor ratings Single phase combinations feature double pole switching as standard Three phase combinations feature internal switch / socket interlocking as standard 19 different pin configurations available as standard, up to 50A three phase IP66 weather protection rating Dual padlocking points Long-life synthetic gasket Earth bonding wire from cover to base supplied with each product as standard Page 20 ROWCO Metal Switched Socket Outlets - IP66 Socket Configurations Cat No RC310DPM RC310LSDPM RC310XDPM RC315DPM RC320DPM RC332DPM Volts 240 240 110 240 240 240 Amps 10 10 10 15 20 32 Yes Yes Rated Operational Voltage Ue (~50Hz) Rated Thermal Current Enclosed Interlock Feature IP Rating c d IP IP66 IP66 IP66 IP66 IP66 IP66 1 Way 1 Way 1 Way 1 Way 1 Way SWITCH Description 1 Way Double Pole Double Pole Double Pole Double Pole Double Pole Double Pole Cable Cross Sections Solid or Standard f g Min (mm2) 1 1 1 1 1 1 Max (mm2) 16 16 16 16 16 16 Switch Rating @ AS3133 0.4pf Inductive 10AX 10AX 10AX 16AX 20AX 32AX 250V M Rating M100 M100 M100 M120 M150 M180 Switch Rating @ EN60947-3 AC23A 240V kW 2.2 2.2 2.2 2.2 3 4 15 15 15 21 28 kW - - - - - - Amp - - - - - - Amps 15 j h AC23A 415V SOCKET Number of Pins Including (Earth Pin) Wiring Diagrams Configuration 3 3 3 (2 Round 3 3 3 (Flat) (Round Live & Flat (Flat) (Round) (Round) Earth) Earth) c d f g h j Cable Cross Sections Solid or Standard Min (mm2) 0.75 0.75 0.75 0.75 1 1 Max (mm2) 10 10 10 10 10 16 Matching Plug (MATRIX Series PLug) Straight MP310 Angled - 3 PIN COMBINATIONS WITH DOUBLE POLE SWITCH MP310X MP315 MP320 MP332 - - MPA320 MPA332 See MATRIX Plug on Pages 26 and 27... For further information. ALL SOCKETS VIEWED FROM FRONT EXTERNAL CONNECTIONS BY CUSTOMER INTERNAL CONNECTIONS NOTES: AC23A Switch of motor loads or other highly inductive loads. AC3 MP310L - Squirrel-cage motors: starting, switching motors off during running. Page 21 ROWCO Metal Switched Socket Outlets - IP66 Cat No RC410M RC420M RC432M RC440M RC450M Volts 415 415 415 415 415 Amps 10 20 32 40 50 Yes Yes Yes Yes Yes IP66 IP66 IP66 IP66 IP66 Rated Operational Voltage Ue (~50Hz) Socket Configurations Rated Thermal Current Enclosed Interlock Feature IP Rating IP SWITCH Description 1 Way 1 Way 1 Way 1 Way 1 Way 3 Pole 3 Pole 3 Pole 3 Pole 3 Pole Min (mm2) 1 1 1 6 6 Max (mm2) 16 16 16 35 35 0.4pf Inductive 10AX 20AX 32AX 50AX 50AX 250V M Rating M100 M150 M180 M250 M250 5.5 7.5 11 15 18 11 15 21 28 35 kW 5.5 11 15 18 15 Amp 11 21 28 35 28 A C D E F G H I J K L M Cable Cross Sections Solid or Standard Switch Rating @ AS3133 Switch Rating @ EN60947-3 AC3 415V kW Amps AC23A 415V SOCKET Number of Pins Including (Earth Pin) 4 (Round) 4 (Round) 4 (Round) 4 (Round) 4 (Round) Configuration A C D E F Min (mm2) 1 1 1 1 4 Max (mm2) 10 10 16 16 25 Cable Cross Sections Solid or Standard Matching Plug (MATRIX Series PLug) Straight MP410 MP420 MP432 MP440 MP450 Angled MPA410 MPA420 MPA432 MPA440 MPA450 RC510M RC520M RC532M RC540M RC550M Volts 415 415 415 415 415 Amps 10 20 32 40 50 Yes Yes Yes Yes Yes IP66 IP66 IP66 IP66 IP66 Cat No Rated Operational Voltage Ue (~50Hz) Rated Thermal Current Enclosed Interlock Feature IP Rating IP SWITCH Description 1 Way 1 Way 1 Way 1 Way 1 Way 3 Pole 3 Pole 3 Pole 3 Pole 3 Pole Min (mm2) 1.0 1.0 1.0 6.0 6.0 Max (mm2) 16 16 16 35 35 Cable Cross Sections Solid or Standard Switch Rating @ AS3133 0.4pf Inductive 10AX 20AX 32AX 50AX 50AX 250V M Rating M100 M150 M180 M250 M250 Switch Rating @ EN60947-3 5AC3 415V kW Amps AC23A 415V 5.5 7.5 11 15 18.5 11 15 21 28 35 kW 5.5 11.0 15.0 18.5 15 Amp 11 21 28 35 28 SOCKET Number of Pins Including (Earth Pin) 5 (Round) 5 (Round) 5 (Round) 5 (Round) 5 (Round) Configuration G H I J K Min (mm2) 1 1 1 1 4 Max (mm2) 10 10 16 16 25 Cable Cross Sections Solid or Standard Matching Plug (MATRIX Series PLug) Straight MP510 MP520 MP532 MP540 MP550 Angled MPA510 MPA520 MPA532 MPA540 MPA550 See MATRIX Plug on Pages 26 and 27... For further information. Page 22 N ROWCO Metal Switched Socket Outlets - IP66 Wiring Diagrams Cat No RC610M RC710M RC720M Volts 415 415 415 Amps 10 10 20 Yes Yes Yes IP66 IP66 IP66 Rated Operational Voltage Ue (~50Hz) Rated Thermal Current Enclosed Interlock Feature IP Rating IP SWITCH Description 4 PIN COMBINATIONS WITH TRIPLE POLE SWITCH 1 Way 1 Way 1 Way 3 Pole 3 Pole 3 Pole Min (mm2) 1 1 1 Max (mm2) 16 16 16 0.4pf Inductive 10AX 10AX 20AX 250V M Rating M100 M100 M150 Cable Cross Sections Solid or Standard Switch Rating @ AS3133 Switch Rating @ EN60947-3 AC23A 240V kW Amps AC23A 415V 5 PIN COMBINATIONS WITH TRIPLE POLE SWITCH 5.5 5.5 11 11 11 21 kW 5.5 5.5 7.5 Amp 11 11 15 Number of Pins Including (Earth Pin) 6 (Round) 7 (Round) 7 (Round) Configuration L M N Min (mm2) 1 1 1 Max (mm2) 10 10 10 SOCKET Cable Cross Sections Solid or Standard Matching Plug (MATRIX Series PLug) 6 PIN COMBINATIONS WITH TRIPLE POLE SWITCH Straight MP610 MP710 MP720 Angled MPA610 MPA710 MPA720 See MATRIX Plug on Pages 26 and 27... For further information. 7 PIN COMBINATIONS WITH TRIPLE POLE SWITCH ALL SOCKETS VIEWED FROM FRONT EXTERNAL CONNECTIONS BY CUSTOMER INTERNAL CONNECTIONS NOTES: AC23A Switch of motor loads or other highly inductive loads. AC3 Squirrel-cage motors: starting, switching motors off during running. Page 23 ROWCO Junction Boxes – IP66 Dimensional Drawings RJ1 RJ1 A range of versatile junction / utility boxes for use in harsh industrial environments. Both sizes allow the mounting of equipment on din rail or gear tray internally as standard. Feature: • • • • • • • Lid can be drilled out to take 22mm or 30mm Telemecanique control equipment Bases can accept a section of din rail or a gear tray for the secure, protected mounting of field equipment Multiple earthing points as standard Multiple mounting options IP66 weather protection rating Long-life synthetic gasket Earth bonding wire from cover to base supplied with each product as standard Page 24 ROWCO Junction Boxes – IP66 Dimensional Drawings RJ2 Cat No RJ1 RJ2 Frame Size Size 1 Size 2 25 mm2 2 - 32 mm2 1 2 40 mm2 - 1 25/32 mm2 1 2 32 mm2 - - 40 mm2 - - Length mm 137 238 Width mm 99 120 Depth mm 96.2 96.2 Number of Mounting Conduit Entries Back Entry Cut-outs Dimensions Page 25 MATRIX Straight and Angled Plugs - IP66 Dimensional Drawings MP210 A comprehensive range of plugtops and cord extension sockets for single phase applications. All plugtops are rated to IP66 when matched to an IP66 socket, combination or cord extension socket. Designed for the food industry, MATRIX plugtops allow superior hygiene standards to be maintained where they are most important. Clean product lines minimise areas where food or waste can build up. The new small frame size MATRIX plugtops boast an M20 rear thread and standard external components, allowing cable connection flexibility and simplified maintenance. MP410 Feature: • IP66 rated • Transparent body • Designed for the food industry • M20 rear thread on small frame size plugtops, allowing flexibility in cable connection • Small frame size plugtops all share the same external components, allowing for simplified maintenance stockholdings and minimised machine downtime when replacement products are needed • All plugs feature the certainty of a cord clamp and the convenience of rear cable entry for terminals • Fully special chemical resistant option (V) MATRIX plugtops feature clear bodies, allowing for quick and easy inspection of the terminals, cord clamping and cable entry areas. Special chemical resistant versions of plugtops are available for use in harsh chemical environments. These plugtops are fully orange, without clear bodies. Page 26 MATRIX Straight and Angled Plugs - IP66 Plug Configurations Cat No. (Straight) Cat No. (Angled) MP310 MP310L MP310X MP315 MP320 MPA320 Rated Operational Voltage Ue (~50Hz) Volts 250 250 110 250 250 20 Rated Thermal Current Enclosed c d 10 10 10 15 Number of Pins Amps 3 3 (2 Flat and 3 (2 Round 3 (Include Earth Pin) (Flat) Round Earth) and Flat Earth) (Flat) Plug Configuration f g 3 (Round) c d f g h 6 6 6 6 7 Cable Entry Diameter Min (mm) Max (mm) 9 12.5 12.5 12.5 16 Terminal Capacity Min (mm2) 0.75 0.75 0.75 1 1 Max (mm2) 1.5 1.5 1.5 2.5 6 IP66 IP66 IP66 IP66 IP66 IP Rating IP Cat No. (Straight) MP332 MP410 MP420 MP432 MP440 Cat No. (Angled) MPA332 MPA410 MPA420 MPA432 MPA440 250 500 500 500 500 40 Rated Operational h j Voltage Ue (~50Hz) Volts Rated Thermal Current Enclosed 32 10 20 32 Number of Pins Amps 3 4 4 4 4 (Include Earth Pin) (Round) (Round) (Round) (Round) (Round) Plug Configuration A D C E j A C D E 10 7 7 10 10 Cable Entry Diameter Min (mm) Max (mm) 27 16 16 27 27 Terminal Capacity Min (mm2) 2.5 1 1 2.5 2.5 Max (mm2) 16 6 6 16 16 IP66 IP66 IP66 IP66 IP66 IP Rating IP Cat No. (Straight) MP450 MP510 MP520 MP532 MP540 Cat No. (Angled) MPA450 MPA510 MPA520 MPA532 MPA540 500 500 500 500 500 50 Rated Operational Voltage Ue (~50Hz) Volts Rated Thermal Current Enclosed F G 50 20 32 40 Number of Pins Amps 4 5 5 5 5 (Include Earth Pin) (Round) (Round) (Round) (Round) (Round) Plug Configuration H I F G H I J 10 7 7 10 10 Cable Entry Diameter Min (mm) Max (mm) 27 16 16 27 27 Terminal Capacity Min (mm2) 4 1 1 2.5 2.5 Max (mm2) 16 6 6 16 16 IP66 IP66 IP66 IP66 IP66 IP Rating IP Cat No. (Straight) MP550 MP610 MP710 MP720 Cat No. (Angled) MPA550 MPA610 MPA710 MPA720 500 500 500 500 20 Rated Operational Voltage J K Ue (~50Hz) Volts Rated Thermal Current Enclosed 10 10 Number of Pins Amps 5 6 7 7 (Include Earth Pin) (Round) (Round) (Round) (Round) Plug Configuration L L M N 7 7 7 Min (mm) Max (mm) 27 16 16 16 Terminal Capacity Min (mm2) 4 1 1 1 Max (mm2) 16 6 6 6 IP66 IP66 IP66 IP66 M IP Rating N K 10 Cable Entry Diameter IP Page 27 VARIO Add-on Auxiliary Contacts Dimensional Drawings VZ20 FEDERAL Series offer 2 VARIO Clip-on auxiliaries contacts for control circuit applications. Both auxiliaires are easily clippied to the switch. Feature: • Clip on auxiliaries cover both LV and ELV applications. • The VZ7 offer 1x late N/O, 1x early break N/C contacts. Some switches can accept 2 Auxiliaries. Page 28 VARIO Add-on Auxiliary Contacts Wiring Diagrams Cat No VZ7 VZ20 Volts 415 415 Volts 690 690 6 6 10 10 Rated Operational Voltage Ue (~50Hz) Rated Insulation Voltage 14 13 21 22 Ui (~50Hz) Rated Impulse Withstand Voltage Uimp (~50Hz) kV Rated Thermal VZ7 Current Enclosed Amps Auxiliary Contact Discriptions 14 13 24 23 N/O+N/C* N/O+N/O Cable Cross Sections Solid or Standard VZ20 Flexible cable + cable end mm2 Solid cable mm2 2 x 0.75 ... 1.5 2 x 0.75 ... 1.5 2 x 1 ... 2.5 2 x 1 ... 2.5 AC Switch Rating @ EN60947-5 AC15 230V Amps 6 6 240V Amps 6 6 400V Amps 4 4 415V Amps 4 4 DC Switch Rating @ EN60947-5 DC11 24V Amps 8 8 48V Amps 8 8 60V Amps 4 4 110V Amps 2 2 220V Amps 1 1 250V Amps 0.8 0.8 *Late make N / O, early break N / C contacts Page 29 Socket Configurations 240 Volt - To AS3112 and AS3123 10A 10A 10A 15A 32A 20A 3 pin 310LS 310 d c 310X f 320 315 h g 500 Volt - To AS3124 10A 20A 32A 40A 50A 4 pin 410 A 420 C 432 D 440 E 450 F 5 pin 520 510 H G 532 I 540 J 550 K 6 pin 610 L 7 pin 720 710 M N Page 30 332 j Plug Configurations 240 Volt - To AS3112 and AS3123 10A 10A 10A 15A 32A 20A 3 pin 310 c 310LS d 310X f 315 g 320 h 500 Volt - To AS3124 10A 20A 32A 40A 50A 4 pin 410 A 420 C 432 D 440 E 450 F 5 pin 520 510 H G 532 I 540 J 6 pin 610 L 7 pin 720 710 M N Page 31 550 K 332 j Rating Conversion 1 Phase 3 Phase kW hp 415V A 500V A kW hp 240V A 0.37 0.55 0.75 1.1 1.5 0.5 0.75 1 1.5 2 3.6 4.8 6.1 8.8 11.7 0.37 0.55 0.75 1.1 1.5 0.5 0.75 1 1.5 2 2 2.5 3.5 1 1.21 1.5 2 2.6 1.8 2.2 3 4 4.4 2.5 3 4 5 6 14.4 17.1 22.2 27.1 31.8 2.2 3 3.7 4 5.5 3 4 5 5.5 7.5 5 6.5 7.5 8.4 11 3.8 5 5.9 6.5 9 7.5 9 10 11 15 10 12 13.5 15 20 14 17 21 28 12 13.9 15 18.4 23 18.5 22 25 30 33 25 30 35 40 45 35 40 47 55 60 28.5 33 39.4 45 50 37 40 45 51 55 50 54 60 70 75 66 71 80 90 100 55 60 65 75 80 59 63 75 80 85 100 105 115 135 85 89 125 These values are given as a guide only. They may vary depending on the type of motor and the manufacturer. Page 32 Switch Rating Information AS3947-3 AC23A - Switching of motor or other highly inductive loads. As above, this rating covers AC supply and frequent operation. AC23A is the best utilisation category for switching of most common types of motors. Most other highly inductive loads typically involve motors of some type. Examples are heat pumps, compressors and air conditioners. The AC23A rating of an WR350M switch is 35is Amps (18.5kW). ThisThis switch can can be matched to ato motor thatthat has has a fulla full loadload current MSW350WH switch 35 Amps (18.5kW). switch be matched a motor of up to of 35up Amps. current to 35 Amps. Generally these switches are used in conjunction with other motor control equipment such as motorstarters or soft starters and only have to operate during a fault or period of isolation. AS3947-3 AC3 - Switching of squirrel cage motors. AC3 has no A or B classification for frequency of operation and all ratings are for frequent operation, as described above. AC3 provides ratings directly applicable to the direct starting and switching off of motors during operation and as such is one of the harshest switch ratings available for motors. The AC3 rating of an WR350M switch is 28 Amps (15kW). This switch can be used to start or stop a motor that has a full load current of up to 28 Amps. AC3 is the rating best suited for control equipment being turned on or off directly under load. Examples include conveyors, lathes and process equipment. With a frequent operation classification, these switches may be operated many times per hour. AS3947-5 AC15 - Control of electromagnetic loads. This rating covers the switch control of electromagnetic loads, including control devices such as relays, contactors and valves. AS3947-3 DC21A - Switching of DC Resistive loads. As for AC21A except covers DC applications. AS3947-3 Rated short time withstand current (Icw / kA). This is the recommended maximum current the switch can withstand under fault conditions without failing or showing signs of damage and is the switch equivalent of a 4.5kA or 6kA rating assigned to an MCB. Values are expressed as kA. An WR350M switch has a 1.5kA rating so it can carry a 1500 Amp load for 1 second without damage. AS3947-3 requires performance of at least 12x rated current for 1 second. Federal switches offer performance levels much higher than this. IMPORTANT The above information is an opinion only. All installers and equipment users should satisfy themselves as to the suitability of equipment for each particular application. No liability will be accepted for reliance on this information. Page 33 Switch Rating Information AS3947-3 Rated short circuit making capacity (Icm / kAp). This rating provides performance information relating to the presence of a short circuit condition when the switch is switched ON. Values are given as kAp and indicate what current load can be carried until circuit protection devices activate. An WR350M switch has a 2.1kAp rating so it can switch ON a 2100 Amp prospective short circuit and carry it for as long as the principle protection devices (MCB or Fuses) take to operate. A "Rated short circuit breaking capacity" relates to the opposite - switching OFF in the presence of a short circuit condition. This rating is not typically published as circuit protection devices are designed to act before a manual switch operation can be undertaken. Uninterrupted Duty A duty without any off-load period in which the main contacts of an equipment remain closed, whilst carrying a steady current without interruption for periods of more than eight hours (weeks, months, or even years). AS3133 Resistive rating This rating is typically the one quoted most widely for a particular switch. The rating relates to resistive loads with a moderate inductive element. An WR350M switch has a 50 Amp resistive rating so it can switch ON and OFF a resistive load of 50 Amps. AS3133 M Motor Rating M rating indicates the Switch is suitable for control of motors with a nominated locked rotor current of XX amps - MXX. An WR350M switch has an M200 rating so it can switch ON or OFF under locked rotor conditions a Motor with a 200 Amp locked rotor current. The locked rotor current is generally 8 to 10 times the full load current and simulates current draw when a motor is stalled. IMPORTANT The above information is an opinion only. All installers and equipment users should satisfy themselves as to the suitability of equipment for each particular application. No liability will be accepted for reliance on this information. Page 34 IP Ratings 1st Figure 2nd Figure Protection against solid objects. Protection against harmful lngress of water. 2 1 Protected against solid bodies larger than 12mm. (e.g. finger of the hand) Protected against vertically falling drops of water. 3 2 Protected against solid bodies larger than 2.5mm. (e.g. tools, wire) Protected against drops of water falling at up to 15° from the vertical. 4 3 Protected against solid bodies larger than 1mm. (fine tools and small wires) Protected against spraying water at up to 60° from the vertical. 5 4 Protected against dust (no harmful deposits) Protected against splashing water from all directions. 6 5 Completely protected against dust Protected against jets of water from all directions. 6 Protected against jets of water of similar force to heavy seas. Page 35 AUS031102 As standards, specifications change from time to time. Please ask for confirmation of the information given in this publication.