Federal Rowco Brochure

Transcription

Federal Rowco Brochure
Federal/Rowco . . . Heavy Duty Industrial Switchgear Solutions
Built to Last
Heavy Duty
The FEDERAL & ROWCO range uses diecast
aluminium exteriors that offer excellent impact
resistance, ensuring long product life, indoors or
outdoors. The materials used are proven to
operate in extreme temperatures from –20oC to
+60oC ambient.
FEDERAL & ROWCO products have been in the
field for decades, with a reputation for
performance excellence in harsh environments.
Use FEDERAL & ROWCO where you need a
product that can take a beating or withstand high
temperatures without compromising performance
or safety.
Switch status information is cast onto product to
ensure it is visible even in the harshest of
conditions.
Both FEDERAL and ROWCO products are made
from high quality aluminium, providing you a
lightweight, corrosion resistant product suitable
for demanding industrial applications, where
safety and durability is a priority.
IP Rating
FEDERAL and ROWCO are true heavy duty
industrial solutions.
FEDERAL & ROWCO products are rated to IP66.
FEDERAL & ROWCO synthetic gaskets provide
high performance protection in all situations for
peace of mind.
Rigorous Testing
FEDERAL switches are the most versatile available.
Besides testing to AS3133, FEDERAL switches
have been tested to EN60947-3, providing several
specialist ratings specific to certain applications.
This means that a FEDERAL switch can be
matched directly and accurately to an application,
providing confidence to specifiers and end-users.
All FEDERAL one-way switches are Switch
Disconnectors, meaning they are suitable for use
as isolating switches.
Modular Design
Based upon 3 frame sizes, the FEDERAL &
ROWCO range has been designed as a family of
products, allowing interchangeability. This means
that junction / utility boxes can be mounted and
with only a cover change, can be turned into a
switch or switched socket outlet.
Besides ensuring versatility, the vigorous testing
regime undertaken by FEDERAL switches is
testament to the superior quality of the product
offer. This superiority translates to less equipment
downtime and improved safety in the workplace,
both issues of great importance to business
managers and their technical experts.
The same high-performance switches used in
FEDERAL are also used in all ROWCO switched
socket outlets.
Page 2
Safety in action
Easy installation
ROWCO switched socket outlets have been
designed for safety. All single phase products
feature double pole switching and all three phase
products feature an interlock mechanism between
switch and socket. This prevents the insertion or
withdrawal of plugtops when the switch is in the
ON position.
FEDERAL and ROWCO products were designed
with installers in mind. All products can be
mounted using internal or external options,
depending on what the application requires. This
flexibility extends to the earthing point - these can
be relocated within the enclosure to suit on-site
requirements.
All switches can be padlocked off in two locations.
Each of these two padlock positions can accept an
8mm hasp padlock or a scissor lockout tag. This
feature supports important occupational health
and safety procedures employed throughout
industry.
All larger switches in the FEDERAL range are base
mounted, in recognition of the large cable sizes
used in these applications. Through this we
support simpler and faster installation.
All products are supplied with stainless steel cover
screws. These screws offer excellent noncorrosive properties and are treated to prevent
chemical reaction with the aluminium castings.
These cover screws are standard metric thread, so
alternatives can be easily arranged should the need
arise.
All conduit entry points and rear cut-out guides are
metric for familiarity and ease of use.
FEDERAL Metal Isolator Switches
Size 1
1 Pole
Size 2
Size 3
20A
32A
20A
32A
40A
50A
63A
80A
4 Pole
20A
32A
40A
50A
63A
80A
6 Pole
20A
32A
3 Pole
7 Pole
16A
63A
32A
FEDERAL Metal Changeover Switches
FEDERAL Metal Forward / Reverse Switches
Page 3
100A
125A
FEDERAL Metal Isolator Switches
•
•
•
FEDERAL Metal Isolator Switches
•
•
•
Page 4
14
Frame Size 1
1 Pole – 4 Pole
20A – 32A
FEDERAL Metal Changeover and
Forward / Reverse Switches
•
•
•
12
Frame Size 3
3 Pole – 6 Pole
63A – 125A
FEDERAL Metal Changeover and
Forward / Reverse Switches
•
•
•
8
Frame Size 2
3 Pole – 7 Pole
20A – 63A
FEDERAL Metal Isolator Switches
•
•
•
6
Frame Size 1
1 Pole – 4 Pole
16A – 32A
Frame Size 2 & Frame Size 3
3 Pole - 4 Pole
32A - 63A
16
Contents
FEDERAL Metal Retrofit Isolator Switches
•
•
•
Frame Size A & B
3 Pole – 4 Pole
20A – 32A
ROWCO Metal Switched Socket Outlets
•
•
•
26
3 Pin – 7 Pin
10A – 50A
VARIO Add-on Auxiliary Contacts
Page 5
24
Frame Size 1 & 2
MATRIX Straight and Angled Plugs
•
•
20
Frame Size 2
3 Pin – 7 Pin
10A – 50A
ROWCO Junction Boxes
•
18
28
FEDERAL Metal Isolator Switches - IP66
Dimensional
Drawings
WR320M
Frame Size 1
Feature:
A range of top-performing switches built to
handle heavy duty environments. FEDERAL
isolator switches are industry leaders, in
terms of versatility, range and ease of
installation.
•
•
•
•
•
•
•
•
•
All switches meet the requirements of
isolation required by AS3000:2000 and are
classified as Switch Disconnectors under
AS3947-3.
1 - 4 pole switches up to 32A
Cover mounted switch mechanisms
Comprehensive switching ratings
IP66 weather protection rating
Dual padlocking points
Multiple earthing points
Multiple mounting options
Long-life synthetic gasket
Earth bonding wire from cover to base
supplied with each product as standard
All versions feature ease of installation
benefits, multiple ratings for versatility and
have been designed to ensure user safety.
Wiring
Diagrams
Page 6
A
Single Pole,
Single Throw
B
Triple Pole,
Single Throw
C
Four Pole,
Single Throw
FEDERAL Metal Isolator Switches - IP66
Cat No
WR120M
WR132M
WR316M
WR320M
WR332M
WR420M
WR432M
Volts
240
240
415
415
415
415
415
Volts
660
660
660
660
660
690
690
2.5
2.5
2.5
2.5
2.5
6
6
20
32
20
32
Rated Operational Voltage
Ue (~50Hz)
Rated Insulation Voltage
Ui (~50Hz)
Rated Impulse Withstand Voltage
Uimp (~50Hz)
kV
Rated Thermal Current Enclosed
20
32
16
Rated Duty
Amps
Uninterrupted
Uninterrupted
Uninterrupted Uninterrupted
Uninterrupted Uninterrupted
Uninterrupted
Description
Single
Single
3 Pole
3 Pole
3 Pole
4 Pole
4 Pole
Pole
Pole
Wiring Diagram
A
A
B
B
B
C
C
Frame Size
Size 1
Size 1
Size 1
Size 1
Size 1
Size 1
Size 1
Switch Mounting Type
Cover
Cover
Cover
Cover
Cover
Cover
Cover
Mount
Mount
Mount
Mount
Mount
Mount
Mount
Cable Cross Sections
Min (mm2)
1
1
1
1
1
1
1
Max (mm2)
16
16
16
16
16
10
10
0.4pf Inductive
20AX
32AX
-
-
-
-
-
415V M Rating
M150
M180
M120
M150
M180
-
-
Solid or Standard
Switch Rating @ AS3133
Switch Rating @ EN60947-3
AC21A 415V
AC23A 240/415V
Amps
20
32
16
20
32
20
32
3
4
7.5
11
15
7.5
11
21
28
15
21
28
14
21
2.2
3
5.5
7.5
11
5.5
7.5
Amps
15
21
11
15
21
11
14
Amps
-
-
16
20
32
-
-
1500
1500
1500
1500
300
384
1
1
1
1
1
1
kW
Amps
AC3 240/415V
DC21A 32V
kW
Rated Short Time
Withstand CurrentAmps/1 second 1500
Rated Short Circuit
Making Capacity
kAp
1
NOTES:
AC21A Switch of AC Resistive loads,
including moderate overloads.
AC23A Switch of motor loads or other
highly inductive loads.
AC3
Squirrel-cage motors: starting,
switching motors off during
running.
DC21A Switch of DC Resistive loads,
including moderate overloads.
Page 7
FEDERAL Metal Isolator Switches - IP66
Dimensional
Drawings
WR632M
Frame Size 2
Feature:
A range of top-performing switches built to
handle heavy duty environments. FEDERAL
isolator switches are industry leaders, in
terms of versatility, range and ease of
installation.
•
•
•
All switches meet the requirements of
isolation required by AS3000:2000 and are
classified as Switch Disconnectors under
AS3947-3.
All versions feature ease of installation
benefits, multiple ratings for versatility and
have been designed to ensure user safety.
•
•
•
•
•
•
•
•
Up to 7 pole 32A switches
Up to 4 pole 63A switches
Base mounted switch mechanisms
- with safety interlock
Comprehensive switching ratings
IP66 weather protection rating
Dual padlocking points
Multiple earthing points
Multiple mounting options
Long-life synthetic gasket
Earth bonding wire from cover to base
supplied with each product as standard
Circuit or product ID recess
All switches are base mounted, with safety
interlock to ensure cover cannot be removed
with switch in the on position.
Page 8
FEDERAL Metal Isolator Switches - IP66
Wiring
Diagrams
Cat No
WR340M
WR350M
WR363M
WR440M
Volts
415
415
415
415
Volts
660
690
690
690
kV
2.5
2.5
6
6
40
Rated Operational Voltage
Ue (~50Hz)
Rated Insulation Voltage
Ui (~50Hz)
B
Triple Pole,
Single Throw
Rated Impulse Withstand Voltage
Uimp (~50Hz)
Rated Thermal Current Enclosed
Amps
C
Four Pole,
Single Throw
40
50
63
Rated Duty
Uninterrupted
Uninterrupted
Uninterrupted
Uninterrupted
Description
3 Pole
3 Pole
3 Pole
4 Pole
C
Wiring Diagram
B
B
B
Frame Size
Size 2
Size 2
Size 2
Size 2
Switch Mounting Type
Cover Mount
Base Mount
Base Mount
Base Mount
Min (mm2)
6
6
2.5
1
Max (mm2)
35
35
25
10
Cable Cross Sections
Solid or Standard
Switch Rating @ AS3133
0.4pf Inductive
-
-
-
-
415V M Rating
M200
M250
-
-
Switch Rating @ EN60947-3
AC21A 415V
Amps
AC23A 240/415V
kW
AC3 240/415V
DC21A 32V
40
50
63
40
18.5
18.5
22
15
Amps
35
35
40
28
kW
15
15
18.5
11
Amps
28
28
35
21
Amps
40
50
-
-
2500
1500
756
480
2.5
2.1
2.1
1
-
1
1
-
Rated Short Time
Withstand Current
Amps/1 second
Rated Short Circuit
Making Capacity
kAp
Maximum number of
Add-on Auxiliary Contact
Module
See VARIO Add-on Auxiliary Contact on page 28 for further information.
Page 9
FEDERAL Metal Isolator Switches - IP66
Cat No
WR450M
WR463M
WR620M
WR632M
WR732M
Volts
415
415
415
415
415
Volts
690
690
690
690
690
6
6
6
6
6
50
63
20
32
32
Rated Duty
Uninterrupted
Uninterrupted
Uninterrupted
Uninterrupted
Uninterrupted
Description
4 Pole
4 Pole
6 Pole
6 Pole
7 Pole
Wiring Diagram
C
C
D
D
E
Frame Size
Size 2
Size 2
Size 2
Size 2
Size 2
Switch Mounting Type
Base Mount
Base Mount
Base Mount
Base Mount
Base Mount
Min (mm2)
2.5
2.5
1
1
1
Max (mm2)
25
25
10
10
10
Rated Operational Voltage
Ue (~50Hz)
Wiring
Diagrams
Rated Insulation Voltage
Ui (~50Hz)
Rated Impulse Withstand Voltage
Uimp (~50Hz)
kV
Rated Thermal Current Enclosed
Amps
C
Four Pole,
Single Throw
D
Six Pole,
Single Throw
Cable Cross Sections
Solid or Standard
Switch Rating @ AS3133
0.4pf Inductive
-
-
-
-
-
415V M Rating
-
-
-
-
-
Switch Rating @ EN60947-3
AC21A 415V
AC23A 240/415V
AC3 240/415V
DC21A 32V
Amps
50
63
20
32
32
kW
22
22
7.5
11
11
Amps
40
40
14
21
21
18.5
18.5
5.5
7.5
7.5
Amps
35
35
11
14
14
Amps
-
-
-
-
-
Amps/1 second
756
756
300
384
384
kAp
2.1
2.1
1
1
1
kW
Rated Short Time
Withstand Current
Rated Short Circuit
Making Capacity
Page 10
E
Seven Pole,
Single Throw
Page 11
FEDERAL Metal Isolator Switches - IP66
Dimensional
Drawings
WR3125M
Frame Size 3
Feature:
A range of top-performing switches built to
handle heavy duty environments. FEDERAL
isolator switches are industry leaders, in
terms of versatility, range and ease of
installation.
•
•
•
•
•
•
•
•
•
•
•
All switches meet the requirements of
isolation required by AS3000:2000 and are
classified as Switch Disconnectors under
AS3947-3.
All versions feature ease of installation
benefits, multiple ratings for versatility and
have been designed to ensure user safety.
•
Up to 3 pole 125A switches
Up to 4 pole 80A switches
Up to 6 pole 63A switches
Base mounted switch mechanisms
Comprehensive switching ratings
IP66 weather protection rating
Dual padlocking points
Multiple earthing points
Multiple mounting options
Long-life synthetic gasket
Earth bonding wire from cover to base
supplied with each product as standard
Circuit or product ID recess
All switches are base mounted, with safety
interlock to ensure cover cannot be removed
with switch in the on position.
Page 12
FEDERAL Metal Isolator Switches - IP66
Wiring
Diagrams
Cat No
WR380M
WR3100M
WR3125M
WR480M
WR663M
Volts
415
415
415
415
415
Volts
690
690
690
690
690
6
6
6
6
6
Rated Operational Voltage
Ue (~50Hz)
Rated Insulation Voltage
Ui (~50Hz)
Rated Impulse Withstand Voltage
Triple Pole,
Single Throw
B
Uimp (~50Hz)
kV
Rated Thermal Current Enclosed
Amps
Four Pole,
Single Throw
C
80
100
125
80
63
Rated Duty
Uninterrupted
Uninterrupted
Uninterrupted
Uninterrupted
Uninterrupted
Description
3 Pole
3 Pole
3 Pole
4 Pole
6 Pole
Wiring Diagram
B
B
B
C
D
Frame Size
Size 3
Size 3
Size 3
Size 3
Size 3
Switch Mounting Type
Base Mount
Base Mount
Base Mount
Base Mount
Base Mount
Min (mm2)
2.5
10
10
2.5
2.5
Max (mm2)
25
95
95
25
25
0.4pf Inductive
-
-
-
-
-
415V M Rating
-
-
-
-
-
Cable Cross Sections
Solid or Standard
Switch Rating @ AS3133
Switch Rating @ EN60947-3
Six Pole,
Single Throw
D
AC21A 415V
AC23A 240/415V
AC3 240/415V
Amps
80
100
125
80
63
kW
30
37
37
30
22
Amps
55
66
66
55
40
kW
22
30
30
22
18.5
Amps
40
55
55
40
35
Amps
-
-
-
-
-
Amps/1 second
960
1500
1500
960
756
kAp
2.1
2.8
2.8
2.1
2.1
1
2
2
2
1
DC21A 32V
Rated Short Time
Withstand Current
Rated Short Circuit
Making Capacity
Maximum Number of
Add-on Auxiliary Contact
Module
See VARIO Add-on Auxiliary Contact on page 28 for further information.
NOTES:
AC21A Switch of AC Resistive loads,
including moderate overloads.
AC23A Switch of motor loads or other
highly inductive loads.
AC3
Squirrel-cage motors: starting,
switching motors off during
running.
DC21A Switch of DC Resistive loads,
including moderate overloads.
Page 13
FEDERAL Metal Changeover and Forward/Reverse Switches – IP66
Dimensional
Drawings
Frame Size 1
WRC320M
Frame Size 1
A range of changeover and forward / reverse
switches suited for harsh industrial
environments.
With comprehensive motor ratings, these
switches are ready for heavy duty
applications.
All versions feature ease of installation
benefits, multiple ratings for versatility and
have been designed to ensure user safety.
Feature:
• Comprehensive motor ratings for each
model
• Heavy duty performance
• IP66 weather protection rating
• Dual padlocking points
• Multiple earthing points
• Multiple mounting options
• Long-life synthetic gasket
• Earth bonding wire from cover to base
supplied with each product as standard
• Circuit or product ID recess
Changeover Switches
• 1 & 3 pole, 20A & 32A ratings
• Cover mounted switch mechanisms
Reversing Switches
• 3 pole at 20A & 32A rating
• Cover mounted mechanism
Page 14
FEDERAL Metal Changeover and Forward/Reverse Switches – IP66
Wiring
Diagrams
Cat No
WRC120M
WRC132M
WRC320M
WRC332M
WRC420M
Volts
240
240
415
415
415
Amps
Rated Operational
Voltage Ue (~50Hz)
Rated Thermal
Single Pole Changeover
Switch, Double
Throw with Centre off
A
Current Enclosed
20
32
20
32
20
Wiring Diagram
A
A
B
B
C
Description
1 Pole
1 Pole
3 Pole
3 Pole
4 Pole
Changeover
Changeover
Changeover
Changeover
Changeover
Size 1
Size 1
Size 1
Size 1
Size 1
2 x 2.5
2x6
2 x 2.5
2x6
2 x 2.5
-
Frame Size
Cable Cross Sections
mm2
Solid or Standard
Switch Rating @ EN60947-3
Triple Pole Changeover
Switch, Double Throw
with Centre Off
B
AC21A 415V, 1 Phase
Amps
20A
32A
-
-
3 Phase
Amps
-
-
20
32
20
AC23A 415V, 3 Phase
kW
-
-
7.5
15
7.5
Amps
AC23A 240V, 1 Phase
kW
Amps
AC3 415V, 3 Phase
AC3 240V, 1 Phase
-
-
15
28
15
2.5
7.5
-
-
-
15
26
-
-
-
kW
-
-
5.5
11
5.5
Amps
-
-
11
21
11
2.2
-
-
-
-
-
-
-
-
-
140
480
140
480
140
kW
Amps
Rated Short Circuit Time
Withstand Current
Four Pole Changeover
Switch, Double Throw
with Centre Off
C
Amps/1 second
Cat No
WRR320M
WRR332M
Volts
415
415
Amps
Rated Operational
Voltage Ue (~50Hz)
Rated Thermal
Current Enclosed
20
32
Wiring Diagram
D
D
Description
3 Pole
3 Pole
Frame Size
Reversing
Reversing
Size 1
Size 1
2 x 2.5
2x6
Cable Cross Sections
mm2
Solid or Standard
Switch Rating @ EN60947-3
AC21A 415V, 1 Phase
Amps
-
-
3 Phase
Amps
20
32
7.5
15
AC23A 415V, 3 Phase
kW
Amps
AC3 415V, 3 Phase
kW
Amps
15
28
5.5
11
11
21
140
480
Rated Short Circuit Time
Withstand Current
Amps/1 second
D
NOTES:
AC21A Switch of AC Resistive loads,
including moderate overloads.
AC23A Switch of motor loads or other
highly inductive loads.
AC3
Squirrel-cage motors: starting,
switching motors off during
running.
Page 15
FEDERAL Metal Changeover and Forward/Reverse Switches – IP66
Dimensional
Drawings
Frame Size 2
WRC432M
Frame Size 2 & Frame Size 3
A range of changeover and forward / reverse switches
suited for harsh industrial environments.
With comprehensive motor ratings, these switches are
ready for heavy duty applications.
All versions feature ease of installation benefits, multiple
ratings for versatility and have been designed to ensure
user safety.
Feature:
•
•
•
•
•
•
•
•
•
Comprehensive motor ratings for each model
Heavy duty performance
IP66 weather protection rating
Dual padlocking points
Multiple earthing points
Multiple mounting options
Long-life synthetic gasket
Earth bonding wire from cover to base supplied with
each product as standard
Circuit or product ID recess
Changeover switches
•
•
4 pole at 32A and 3 pole at 63A ratings
Cover mounted (32A) and Base mounted (63A) switch
mechanisms
Reversing switches
•
•
3 pole at 63A ratings
Base mounted (63A) switch mechanisms
Page 16
Frame Size 3
FEDERAL Metal Changeover and Forward/Reverse Switches – IP66
Wiring
Diagrams
Cat No
WRC432M
Rated Operational
Voltage Ue (~50Hz)
Volts
415
Amps
32
Rated Thermal
Current Enclosed
Wiring Diagram
C
Description
4 Pole
Frame Size
Size 2
Changeover
Cable Cross Sections
Triple Pole Changeover
Switch, Double Throw
with Centre Off
B
mm2
Solid or Standard
2x6
Switch Rating @ EN60947-3
AC21A 415V, 1 Phase
Amps
3 Phase
Amps
32
AC23A 415V, 3 Phase
kW
15
Amps
28
AC3 415V, 3 Phase
-
kW
11
Amps
21
Rated Short Circuit Time
Withstand Current
Amps/1 second
480
480
Four Pole Changeover
Switch, Double Throw
with Centre Off
C
Cat No
WRC363M
WRR363M
Volts
415
415
Amps
63
63
Rated Operational
Voltage Ue (~50Hz)
Rated Thermal
Current Enclosed
Wiring Diagram
B
E
Description
3 Pole
3 Pole
Changeover
Reversing
Frame Size
Size 3
Size 3
2 x 16
2 x 16
-
E
Cable Cross Sections
mm2
Solid or Standard
Switch Rating @ EN60947-3
AC21A 415V, 1 Phase
Amps
-
3 Phase
Amps
63
63
AC23A 415V, 3 Phase
kW
30
30
Amps
55
55
18.5
18.5
35
35
1000
1000
AC3 415V, 3 Phase
kW
Amps
Rated Short Circuit Time
Withstand Current
Amps/1 second
NOTES:
AC21A Switch of AC Resistive loads,
including moderate overloads.
AC23A Switch of motor loads or other
highly inductive loads.
AC3
Squirrel-cage motors: starting,
switching motors off during
running.
Page 17
FEDERAL Metal Retrofit Isolator Switches - IP56
Dimensional
Drawings
Frame Size A
WR432RFM
Frame size A & B
Feature:
A range of isolators designed to install onto
existing enclosures for simplified
maintenance.
•
To support existing installations into the
future, these switches offer the variety of
ratings available on standard FEDERAL
isolators.
•
•
•
•
•
•
•
Comprehensive motor ratings for each
model
Heavy duty performance
IP56 weather protection rating
Dual padlocking points
Supplied without base
Long-life synthetic gasket
Earth bonding wire from cover to base
supplied with each product as standard
Circuit or product ID recess
Page 18
Frame Size B
FEDERAL Metal Retrofit Isolator Switches - IP56
Wiring
Diagrams
Cat No
WR320RFM
WR332RFM
WR432RFM*
Volts
415
415
415
Volts
690
690
690
6
6
6
20
32
32
Rated Operational Voltage
Ue (~50Hz)
Rated Insulation Voltage
Ui (~50Hz)
Rated Impulse Withstand Voltage
Triple Pole,
Single Throw
B
Uimp (~50Hz)
kV
Rated Thermal Current Enclosed
Amps
Four Pole,
Single Throw
C
Rated Duty
Uninterrupted Uninterrupted Uninterrupted
Description
3 Pole
3 Pole
Wiring Diagram
B
B
C
Frame Size
Size A
Size B
Size B
Switch Mounting Type
Base Mount
Base Mount
Base Mount
Min (mm2)
1
1
1
Max (mm2)
10
10
10
25
32
32
5.5
5.5
-
20
20
-
7.5
11
11
14
21
21
4
4
-
14
14
-
4 Pole
Cable Cross Sections
Solid or Standard
Switch Rating @ EN60947-3
AC21A 415V
Amps
AC23A 240V
kW
Amps
AC23A 415V
kW
Amps
AC3 240V
kW
Amps
AC3 415V
kW
Amps
5.5
7.5
7.5
11
14
14
300
384
384
1
1
1
IP 56
IP 56
IP 56
Rated Short Time
Withstand Current
Amps/1 second
Rated Short Circuit Making Capacity
kAp
IP Rating
Correspond to the old version of the Federal Switch.
* Can be used to replace old WR420M and WR435M covers or switch mechanisms
NOTES:
AC21A Switch of AC Resistive loads,
including moderate overloads.
AC23A Switch of motor loads or other
highly inductive loads.
AC3
Squirrel-cage motors: starting,
switching motors off during
running.
DC21A Switch of DC Resistive loads,
including moderate overloads.
Page 19
ROWCO Metal Switched Socket Outlets - IP66
Dimensional
Drawings
RC550M
Frame Size 2
A range of heavy duty switched socket
outlets designed for top performance in
harsh industrial environments.
Feature:
Comprehensive switch ratings, including
motor ratings, are standard across all
products.
•
Safety is a key feature across the range, with
double pole switching on single phase
product and an interlocking mechanism
between switch and socket on three phase
products, as standard.
•
•
•
•
•
•
•
•
One piece combinations
Comprehensive switch ratings, including
motor ratings
Single phase combinations feature
double pole switching as standard
Three phase combinations feature
internal switch / socket interlocking as
standard
19 different pin configurations available
as standard, up to 50A three phase
IP66 weather protection rating
Dual padlocking points
Long-life synthetic gasket
Earth bonding wire from cover to base
supplied with each product as standard
Page 20
ROWCO Metal Switched Socket Outlets - IP66
Socket
Configurations
Cat No
RC310DPM
RC310LSDPM RC310XDPM RC315DPM
RC320DPM
RC332DPM
Volts 240
240
110
240
240
240
Amps 10
10
10
15
20
32
Yes
Yes
Rated Operational
Voltage Ue (~50Hz)
Rated Thermal
Current Enclosed
Interlock Feature
IP Rating
c
d
IP IP66
IP66
IP66
IP66
IP66
IP66
1 Way
1 Way
1 Way
1 Way
1 Way
SWITCH
Description
1 Way
Double Pole Double Pole
Double Pole Double Pole Double Pole
Double Pole
Cable Cross Sections
Solid or Standard
f
g
Min (mm2) 1
1
1
1
1
1
Max (mm2) 16
16
16
16
16
16
Switch Rating @ AS3133
0.4pf Inductive 10AX
10AX
10AX
16AX
20AX
32AX
250V M Rating M100
M100
M100
M120
M150
M180
Switch Rating @ EN60947-3
AC23A 240V
kW 2.2
2.2
2.2
2.2
3
4
15
15
15
21
28
kW -
-
-
-
-
-
Amp -
-
-
-
-
-
Amps 15
j
h
AC23A 415V
SOCKET
Number of Pins Including (Earth Pin)
Wiring
Diagrams
Configuration
3
3
3 (2 Round
3
3
3
(Flat)
(Round
Live & Flat
(Flat)
(Round)
(Round)
Earth)
Earth)
c
d
f
g
h
j
Cable Cross Sections
Solid or Standard
Min (mm2) 0.75
0.75
0.75
0.75
1
1
Max (mm2) 10
10
10
10
10
16
Matching Plug
(MATRIX Series PLug)
Straight MP310
Angled -
3 PIN COMBINATIONS WITH
DOUBLE POLE SWITCH
MP310X
MP315
MP320
MP332
-
-
MPA320
MPA332
See MATRIX Plug on Pages 26 and 27... For further information.
ALL SOCKETS VIEWED
FROM FRONT
EXTERNAL
CONNECTIONS BY
CUSTOMER
INTERNAL
CONNECTIONS
NOTES:
AC23A Switch of motor loads or other
highly inductive loads.
AC3
MP310L
-
Squirrel-cage motors: starting,
switching motors off during running.
Page 21
ROWCO Metal Switched Socket Outlets - IP66
Cat No
RC410M
RC420M
RC432M
RC440M
RC450M
Volts
415
415
415
415
415
Amps
10
20
32
40
50
Yes
Yes
Yes
Yes
Yes
IP66
IP66
IP66
IP66
IP66
Rated Operational
Voltage Ue (~50Hz)
Socket
Configurations
Rated Thermal
Current Enclosed
Interlock Feature
IP Rating
IP
SWITCH
Description
1 Way
1 Way
1 Way
1 Way
1 Way
3 Pole
3 Pole
3 Pole
3 Pole
3 Pole
Min (mm2)
1
1
1
6
6
Max (mm2)
16
16
16
35
35
0.4pf Inductive
10AX
20AX
32AX
50AX
50AX
250V M Rating
M100
M150
M180
M250
M250
5.5
7.5
11
15
18
11
15
21
28
35
kW
5.5
11
15
18
15
Amp
11
21
28
35
28
A
C
D
E
F
G
H
I
J
K
L
M
Cable Cross Sections
Solid or Standard
Switch Rating @ AS3133
Switch Rating @ EN60947-3
AC3 415V
kW
Amps
AC23A 415V
SOCKET
Number of Pins Including (Earth Pin)
4 (Round)
4 (Round)
4 (Round)
4 (Round)
4 (Round)
Configuration
A
C
D
E
F
Min (mm2)
1
1
1
1
4
Max (mm2)
10
10
16
16
25
Cable Cross Sections
Solid or Standard
Matching Plug
(MATRIX Series PLug)
Straight
MP410
MP420
MP432
MP440
MP450
Angled
MPA410
MPA420
MPA432
MPA440
MPA450
RC510M
RC520M
RC532M
RC540M
RC550M
Volts
415
415
415
415
415
Amps
10
20
32
40
50
Yes
Yes
Yes
Yes
Yes
IP66
IP66
IP66
IP66
IP66
Cat No
Rated Operational
Voltage Ue (~50Hz)
Rated Thermal
Current Enclosed
Interlock Feature
IP Rating
IP
SWITCH
Description
1 Way
1 Way
1 Way
1 Way
1 Way
3 Pole
3 Pole
3 Pole
3 Pole
3 Pole
Min (mm2)
1.0
1.0
1.0
6.0
6.0
Max (mm2)
16
16
16
35
35
Cable Cross Sections
Solid or Standard
Switch Rating @ AS3133
0.4pf Inductive
10AX
20AX
32AX
50AX
50AX
250V M Rating
M100
M150
M180
M250
M250
Switch Rating @ EN60947-3
5AC3 415V
kW
Amps
AC23A 415V
5.5
7.5
11
15
18.5
11
15
21
28
35
kW
5.5
11.0
15.0
18.5
15
Amp
11
21
28
35
28
SOCKET
Number of Pins Including (Earth Pin)
5 (Round)
5 (Round)
5 (Round)
5 (Round)
5 (Round)
Configuration
G
H
I
J
K
Min (mm2)
1
1
1
1
4
Max (mm2)
10
10
16
16
25
Cable Cross Sections
Solid or Standard
Matching Plug
(MATRIX Series PLug)
Straight
MP510
MP520
MP532
MP540
MP550
Angled
MPA510
MPA520
MPA532
MPA540
MPA550
See MATRIX Plug on Pages 26 and 27... For further information.
Page 22
N
ROWCO Metal Switched Socket Outlets - IP66
Wiring
Diagrams
Cat No
RC610M
RC710M
RC720M
Volts
415
415
415
Amps
10
10
20
Yes
Yes
Yes
IP66
IP66
IP66
Rated Operational
Voltage Ue (~50Hz)
Rated Thermal
Current Enclosed
Interlock Feature
IP Rating
IP
SWITCH
Description
4 PIN COMBINATIONS WITH
TRIPLE POLE SWITCH
1 Way
1 Way
1 Way
3 Pole
3 Pole
3 Pole
Min (mm2)
1
1
1
Max (mm2)
16
16
16
0.4pf Inductive
10AX
10AX
20AX
250V M Rating
M100
M100
M150
Cable Cross Sections
Solid or Standard
Switch Rating @ AS3133
Switch Rating @ EN60947-3
AC23A 240V
kW
Amps
AC23A 415V
5 PIN COMBINATIONS WITH
TRIPLE POLE SWITCH
5.5
5.5
11
11
11
21
kW
5.5
5.5
7.5
Amp
11
11
15
Number of Pins Including (Earth Pin)
6 (Round)
7 (Round)
7 (Round)
Configuration
L
M
N
Min (mm2)
1
1
1
Max (mm2)
10
10
10
SOCKET
Cable Cross Sections
Solid or Standard
Matching Plug
(MATRIX Series PLug)
6 PIN COMBINATIONS WITH
TRIPLE POLE SWITCH
Straight
MP610
MP710
MP720
Angled
MPA610
MPA710
MPA720
See MATRIX Plug on Pages 26 and 27... For further information.
7 PIN COMBINATIONS WITH
TRIPLE POLE SWITCH
ALL SOCKETS VIEWED
FROM FRONT
EXTERNAL
CONNECTIONS BY
CUSTOMER
INTERNAL
CONNECTIONS
NOTES:
AC23A Switch of motor loads or other
highly inductive loads.
AC3
Squirrel-cage motors: starting,
switching motors off during running.
Page 23
ROWCO Junction Boxes – IP66
Dimensional
Drawings
RJ1
RJ1
A range of versatile junction / utility boxes for
use in harsh industrial environments.
Both sizes allow the mounting of equipment
on din rail or gear tray internally as standard.
Feature:
•
•
•
•
•
•
•
Lid can be drilled out to take 22mm or
30mm Telemecanique control equipment
Bases can accept a section of din rail or a
gear tray for the secure, protected
mounting of field equipment
Multiple earthing points as standard
Multiple mounting options
IP66 weather protection rating
Long-life synthetic gasket
Earth bonding wire from cover to base
supplied with each product as standard
Page 24
ROWCO Junction Boxes – IP66
Dimensional
Drawings
RJ2
Cat No
RJ1
RJ2
Frame Size
Size 1
Size 2
25 mm2
2
-
32 mm2
1
2
40 mm2
-
1
25/32 mm2
1
2
32 mm2
-
-
40 mm2
-
-
Length mm
137
238
Width mm
99
120
Depth mm
96.2
96.2
Number of Mounting
Conduit Entries
Back Entry Cut-outs
Dimensions
Page 25
MATRIX Straight and Angled Plugs - IP66
Dimensional
Drawings
MP210
A comprehensive range of plugtops and cord
extension sockets for single phase
applications. All plugtops are rated to IP66
when matched to an IP66 socket,
combination or cord extension socket.
Designed for the food industry, MATRIX
plugtops allow superior hygiene standards to
be maintained where they are most
important. Clean product lines minimise
areas where food or waste can build up.
The new small frame size MATRIX plugtops
boast an M20 rear thread and standard
external components, allowing cable
connection flexibility and simplified
maintenance.
MP410
Feature:
• IP66 rated
• Transparent body
• Designed for the food industry
• M20 rear thread on small frame size
plugtops, allowing flexibility in cable
connection
• Small frame size plugtops all share the
same external components, allowing for
simplified maintenance stockholdings and
minimised machine downtime when
replacement products are needed
• All plugs feature the certainty of a cord
clamp and the convenience of rear cable
entry for terminals
• Fully special chemical resistant option (V)
MATRIX plugtops feature clear bodies,
allowing for quick and easy inspection of the
terminals, cord clamping and cable entry
areas.
Special chemical resistant versions of
plugtops are available for use in harsh
chemical environments. These plugtops are
fully orange, without clear bodies.
Page 26
MATRIX Straight and Angled Plugs - IP66
Plug
Configurations
Cat No.
(Straight)
Cat No.
(Angled)
MP310
MP310L
MP310X
MP315
MP320
MPA320
Rated Operational
Voltage
Ue (~50Hz) Volts
250
250
110
250
250
20
Rated Thermal
Current Enclosed
c
d
10
10
10
15
Number of Pins
Amps
3
3 (2 Flat and
3 (2 Round
3
(Include Earth Pin)
(Flat)
Round Earth)
and Flat Earth) (Flat)
Plug Configuration
f
g
3
(Round)
c
d
f
g
h
6
6
6
6
7
Cable Entry Diameter
Min (mm)
Max (mm)
9
12.5
12.5
12.5
16
Terminal Capacity
Min (mm2)
0.75
0.75
0.75
1
1
Max (mm2)
1.5
1.5
1.5
2.5
6
IP66
IP66
IP66
IP66
IP66
IP Rating
IP
Cat No.
(Straight)
MP332
MP410
MP420
MP432
MP440
Cat No.
(Angled)
MPA332
MPA410
MPA420
MPA432
MPA440
250
500
500
500
500
40
Rated Operational
h
j
Voltage
Ue (~50Hz) Volts
Rated Thermal
Current Enclosed
32
10
20
32
Number of Pins
Amps
3
4
4
4
4
(Include Earth Pin)
(Round)
(Round)
(Round)
(Round)
(Round)
Plug Configuration
A
D
C
E
j
A
C
D
E
10
7
7
10
10
Cable Entry Diameter
Min (mm)
Max (mm)
27
16
16
27
27
Terminal Capacity
Min (mm2)
2.5
1
1
2.5
2.5
Max (mm2)
16
6
6
16
16
IP66
IP66
IP66
IP66
IP66
IP Rating
IP
Cat No.
(Straight)
MP450
MP510
MP520
MP532
MP540
Cat No.
(Angled)
MPA450
MPA510
MPA520
MPA532
MPA540
500
500
500
500
500
50
Rated Operational
Voltage
Ue (~50Hz) Volts
Rated Thermal
Current Enclosed
F
G
50
20
32
40
Number of Pins
Amps
4
5
5
5
5
(Include Earth Pin)
(Round)
(Round)
(Round)
(Round)
(Round)
Plug Configuration
H
I
F
G
H
I
J
10
7
7
10
10
Cable Entry Diameter
Min (mm)
Max (mm)
27
16
16
27
27
Terminal Capacity
Min (mm2)
4
1
1
2.5
2.5
Max (mm2)
16
6
6
16
16
IP66
IP66
IP66
IP66
IP66
IP Rating
IP
Cat No.
(Straight)
MP550
MP610
MP710
MP720
Cat No.
(Angled)
MPA550
MPA610
MPA710
MPA720
500
500
500
500
20
Rated Operational
Voltage
J
K
Ue (~50Hz) Volts
Rated Thermal
Current Enclosed
10
10
Number of Pins
Amps
5
6
7
7
(Include Earth Pin)
(Round)
(Round)
(Round)
(Round)
Plug Configuration
L
L
M
N
7
7
7
Min (mm)
Max (mm)
27
16
16
16
Terminal Capacity
Min (mm2)
4
1
1
1
Max (mm2)
16
6
6
6
IP66
IP66
IP66
IP66
M
IP Rating
N
K
10
Cable Entry Diameter
IP
Page 27
VARIO Add-on Auxiliary Contacts
Dimensional
Drawings
VZ20
FEDERAL Series offer 2 VARIO Clip-on
auxiliaries contacts for control circuit
applications.
Both auxiliaires are easily clippied to
the switch.
Feature:
• Clip on auxiliaries cover both LV and ELV
applications.
• The VZ7 offer 1x late N/O, 1x early break
N/C contacts.
Some switches can accept 2 Auxiliaries.
Page 28
VARIO Add-on Auxiliary Contacts
Wiring
Diagrams
Cat No
VZ7
VZ20
Volts
415
415
Volts
690
690
6
6
10
10
Rated Operational Voltage
Ue (~50Hz)
Rated Insulation Voltage
14
13
21
22
Ui (~50Hz)
Rated Impulse Withstand Voltage
Uimp (~50Hz)
kV
Rated Thermal
VZ7
Current Enclosed
Amps
Auxiliary Contact Discriptions
14
13
24
23
N/O+N/C* N/O+N/O
Cable Cross Sections
Solid or Standard
VZ20
Flexible cable + cable end mm2
Solid cable mm2
2 x 0.75 ... 1.5 2 x 0.75 ... 1.5
2 x 1 ... 2.5
2 x 1 ... 2.5
AC Switch Rating @ EN60947-5
AC15 230V
Amps
6
6
240V
Amps
6
6
400V
Amps
4
4
415V
Amps
4
4
DC Switch Rating @ EN60947-5
DC11 24V
Amps
8
8
48V
Amps
8
8
60V
Amps
4
4
110V
Amps
2
2
220V
Amps
1
1
250V
Amps
0.8
0.8
*Late make N / O, early break N / C contacts
Page 29
Socket Configurations
240 Volt - To AS3112 and AS3123
10A
10A
10A
15A
32A
20A
3 pin
310LS
310
d
c
310X
f
320
315
h
g
500 Volt - To AS3124
10A
20A
32A
40A
50A
4 pin
410
A
420
C
432
D
440
E
450
F
5 pin
520
510
H
G
532
I
540
J
550
K
6 pin
610
L
7 pin
720
710
M
N
Page 30
332
j
Plug Configurations
240 Volt - To AS3112 and AS3123
10A
10A
10A
15A
32A
20A
3 pin
310
c
310LS
d
310X
f
315
g
320
h
500 Volt - To AS3124
10A
20A
32A
40A
50A
4 pin
410
A
420
C
432
D
440
E
450
F
5 pin
520
510
H
G
532
I
540
J
6 pin
610
L
7 pin
720
710
M
N
Page 31
550
K
332
j
Rating Conversion
1 Phase
3 Phase
kW
hp
415V
A
500V
A
kW
hp
240V
A
0.37
0.55
0.75
1.1
1.5
0.5
0.75
1
1.5
2
3.6
4.8
6.1
8.8
11.7
0.37
0.55
0.75
1.1
1.5
0.5
0.75
1
1.5
2
2
2.5
3.5
1
1.21
1.5
2
2.6
1.8
2.2
3
4
4.4
2.5
3
4
5
6
14.4
17.1
22.2
27.1
31.8
2.2
3
3.7
4
5.5
3
4
5
5.5
7.5
5
6.5
7.5
8.4
11
3.8
5
5.9
6.5
9
7.5
9
10
11
15
10
12
13.5
15
20
14
17
21
28
12
13.9
15
18.4
23
18.5
22
25
30
33
25
30
35
40
45
35
40
47
55
60
28.5
33
39.4
45
50
37
40
45
51
55
50
54
60
70
75
66
71
80
90
100
55
60
65
75
80
59
63
75
80
85
100
105
115
135
85
89
125
These values are given as a guide only.
They may vary depending on the type of motor and the manufacturer.
Page 32
Switch Rating Information
AS3947-3 AC23A - Switching of motor or other highly inductive loads.
As above, this rating covers AC supply and frequent operation. AC23A is the best utilisation category for switching of most
common types of motors. Most other highly inductive loads typically involve motors of some type. Examples are heat pumps,
compressors and air conditioners.
The AC23A rating of an WR350M
switch
is 35is Amps
(18.5kW).
ThisThis
switch
can can
be matched
to ato
motor
thatthat
has has
a fulla full
loadload
current
MSW350WH
switch
35 Amps
(18.5kW).
switch
be matched
a motor
of
up to of
35up
Amps.
current
to 35 Amps.
Generally these switches are used in conjunction with other motor control equipment such as motorstarters or soft starters and only
have to operate during a fault or period of isolation.
AS3947-3 AC3 - Switching of squirrel cage motors.
AC3 has no A or B classification for frequency of operation and all ratings are for frequent operation, as described above. AC3
provides ratings directly applicable to the direct starting and switching off of motors during operation and as such is one of the
harshest switch ratings available for motors.
The AC3 rating of an WR350M switch is 28 Amps (15kW). This switch can be used to start or stop a motor that has a full load
current of up to 28 Amps.
AC3 is the rating best suited for control equipment being turned on or off directly under load. Examples include conveyors, lathes
and process equipment. With a frequent operation classification, these switches may be operated many times per hour.
AS3947-5 AC15 - Control of electromagnetic loads.
This rating covers the switch control of electromagnetic loads, including control devices such as relays, contactors and valves.
AS3947-3 DC21A - Switching of DC Resistive loads.
As for AC21A except covers DC applications.
AS3947-3 Rated short time withstand current (Icw / kA).
This is the recommended maximum current the switch can withstand under fault conditions without failing or showing signs of
damage and is the switch equivalent of a 4.5kA or 6kA rating assigned to an MCB. Values are expressed as kA.
An WR350M switch has a 1.5kA rating so it can carry a 1500 Amp load for 1 second without damage.
AS3947-3 requires performance of at least 12x rated current for 1 second. Federal switches offer performance levels much
higher than this.
IMPORTANT
The above information is an opinion only. All installers and equipment users should satisfy themselves as to the suitability of equipment for
each particular application. No liability will be accepted for reliance on this information.
Page 33
Switch Rating Information
AS3947-3 Rated short circuit making capacity (Icm / kAp).
This rating provides performance information relating to the presence of a short circuit condition when the switch is switched ON.
Values are given as kAp and indicate what current load can be carried until circuit protection devices activate.
An WR350M switch has a 2.1kAp rating so it can switch ON a 2100 Amp prospective short circuit and carry it for as long as the
principle protection devices (MCB or Fuses) take to operate.
A "Rated short circuit breaking capacity" relates to the opposite - switching OFF in the presence of a short circuit condition.
This rating is not typically published as circuit protection devices are designed to act before a manual switch operation can be
undertaken.
Uninterrupted Duty
A duty without any off-load period in which the main contacts of an equipment remain closed, whilst carrying a steady current without
interruption for periods of more than eight hours (weeks, months, or even years).
AS3133 Resistive rating
This rating is typically the one quoted most widely for a particular switch. The rating relates to resistive loads with a moderate
inductive element.
An WR350M switch has a 50 Amp resistive rating so it can switch ON and OFF a resistive load of 50 Amps.
AS3133 M Motor Rating
M rating indicates the Switch is suitable for control of motors with a nominated locked rotor current of XX amps - MXX.
An WR350M switch has an M200 rating so it can switch ON or OFF under locked rotor conditions a Motor with a 200 Amp locked
rotor current. The locked rotor current is generally 8 to 10 times the full load current and simulates current draw when a motor is
stalled.
IMPORTANT
The above information is an opinion only. All installers and equipment users should satisfy themselves as to the suitability of equipment for
each particular application. No liability will be accepted for reliance on this information.
Page 34
IP Ratings
1st Figure
2nd Figure
Protection against solid objects.
Protection against harmful lngress of water.
2
1
Protected against solid bodies larger
than 12mm. (e.g. finger of the hand)
Protected against vertically falling
drops of water.
3
2
Protected against solid bodies larger
than 2.5mm. (e.g. tools, wire)
Protected against drops of water falling
at up to 15° from the vertical.
4
3
Protected against solid bodies larger than
1mm. (fine tools and small wires)
Protected against spraying water at
up to 60° from the vertical.
5
4
Protected against dust (no harmful
deposits)
Protected against splashing water
from all directions.
6
5
Completely protected against dust
Protected against jets of water from
all directions.
6
Protected against jets of water of
similar force to heavy seas.
Page 35
AUS031102
As standards, specifications change from time to time.
Please ask for confirmation of the information given in this publication.