Electrak Lightrak lighting control system
Transcription
Electrak Lightrak lighting control system
Lightrak ... ® KNX lighting control system LIGHTRAK / SYSTEM GUIDE INCLUDING BUSCOM POWERED BY SPECIALISTS LTK_Bro_Covers v1.indd 1 29/08/2012 12:21 ® Electrak ... the specialist in power distribution throughout the workplace Electrak, part of the Legrand Group in the UK, is a leading manufacturer of power distribution and lighting control solutions. Its power track, floor boxes and grommets, desk modules and lighting control ranges are installed in high specification offices around the world. LTK_Bro_002_003 v1.indd 2 29/08/2012 12:14 Legrand is the global specialist in electrical and digital building infrastructures. Innovation is the driving force behind its development. With an increasing investment in research and development (circa 5% of sales) and more than 4,000 active patents, the Legrand Group is focused on maintaining a high rate of new product launches that present innovative solutions to the market. CONTENTS Buscom trunking Lightrak system - features Adapting to changing buildings Integration with KNX and DALI Lightrak sensors System support service Case studies 4 6 8 10 12 14 15 SUSTAINABLE DEVELOPMENT From design through to manufacturing, the Legrand Group selects materials and processes that respect people and the environment. • Efficient and environmentally aware product design • Product functions that help to avoid energy waste • Management of manufacturing and logistics sites • Integration of environmental concerns and ISO 14001 procedures at the Group’s global sites.* ORDERING INFORMATION System components, lighting control units, sub-cabling 16 Standard switching devices 17 Sub-bus addressable devices 18 Buscom trunking 24 - 37 TECHNICAL INFORMATION Lightrak Buscom trunking 19 - 23 38 - 43 * 84% of sites are ISO 14001:2004 accredited including all UK sites. LEGRAND IN THE UK POWERED BY SPECIALISTS In the UK Legrand has developed a customer focused structure which harnesses the power of its market leading specialist brands to deliver innovative, integrated solutions for every phase of construction. LTK_Bro_002_003 v1.indd 3 29/08/2012 12:14 Buscom trunking... a unique power and data backbone Buscom is at the heart of Electrak’s lighting control solutions... distributing both power and communications within a single busbar trunking system, it provides a lexible and simple alternative to traditional wiring installations. THE HEART OF YOUR LIGHTING CONTROL SYSTEM Installing a matrix of Buscom trunking in the ceiling void creates an accessible power and communications backbone throughout a building. The backbone can be tapped into at any point to facilitate instant connection to power and control circuits. Buscom incorporates a shielded twisted pair communications bus inside each length and tap-off, and is suitable for use with any lighting control protocol, including: KNX, LonWorks and DALI. MODULAR. FLEXIBLE. SIMPLE. Trunking lengths simply push it together, saving time and money on installation. With cable terminations only required for power and control circuits in the feed unit, Buscom delivers a plug and play solution that allows for future lighting layout changes to be made quickly and eficiently, whilst drastically reducing the potential points of failure in comparison with traditional wiring methods. 04 • Power and communications within a single trunking system • Suitable for use with any lighting control protocol, including: KNX, LonWorks and DALI • Modular, lexible system which is quick and simple to install and adapt • Reduced potential points of failure in comparison with traditional wiring installations LTK_Bro_004_005 v1.indd 4 29/08/2012 12:15 Buscom adds a new dimension to lighting busbar that extends the unquestionable plug and play advantages from the power circuit to the control circuit. This unique system for distributing lighting control signals delivers unrivalled flexibility, regardless of the location of the intelligence... INTELLIGENCE IN THE PANEL INTELLIGENCE IN THE BUSBAR Lighting control modules located in a central cabinet are connected to the Buscom system via communication circuits that terminate in the feed unit. Control signals are then distributed along the trunking run and made available at any tap-off outlet. Integrating lighting control technology into the Buscom feed unit is particularly effective for DALI control. Each trunking run converts to an individual DALI network into which luminaires can tap-in at any point. INTELLIGENCE IN THE LCU Lighting control units (LCUs) are mounted onto and plugged into Buscom trunking, providing a hub into which multiples of luminaires and switching devices are plugged. Buscom’s integrated communication bus provides the backbone which networks all control devices together. 05 ENERGY SAVING As with all Electrak solutions, Buscom is a modular system designed to be quick and simple to install, reducing man hours and energy usage on site. energy saving LTK_Bro_004_005 v1.indd 5 29/08/2012 12:15 Lightrak ... ® fully addressable lighting control Designed to work in harmony with Electrak’s Buscom trunking, Lightrak’s lighting control system offers high end sophistication with unbeatable lexibility and speed of installation. PRESENCE OR ABSENCE DETECTION Saves energy and ensures that lighting is only on when needed TIMED EVENT CONTROLLER Programmable touch screen units optimise energy saving SCENE SETTING SWITCH Multiple lighting scenarios are memorised and retrieved at the touch of a button EMERGENCY TEST MULTI-GANG SWITCHES Traditional key switch to enable testing of self-contained emergency luminaires 1, 2, 4 and 8 gang options connect via CAT. 5 cable and RJ 45 plugs 06 SNAP ON... PLUG IN Lightrak lighting control units (LCUs) simply snap on and plug into Electrak’s Buscom trunking and are easily unplugged, moved and reprogrammed to accommodate future lighting layout changes. LTK_Bro_006_007 v1.indd 6 29/08/2012 12:16 SOPHISTICATED TECHNOLOGY FULLY ADDRESSABLE Analogue and DSI dimming through to full DALI control in addressable mode. A full KNX network can support in excess of 64,000 KNX devices. Each output of every lighting control unit (LCU) is individually controllable. Lightrak offers full building-wide control for even the largest of projects. Networked over a KNX backbone that can be integrated onto IP or BMS systems. DALI EMERGENCY FEEDBACK WIDE RANGING CONTROL Two way DALI communication facilitates feedback from DALI emergency inverters onto the KNX bus. A comprehensive range of control devices is available: PIR / ultrasonic sensors - wireless reconiguration of sensor parameters - scene setting - remote control - time scheduling - traditional switching and emergency key switch. Monitoring and reporting software can be easily integrated with KNX. DAYLIGHT LINKING ABSENCE DETECTION Lighting levels are adjusted in relation to the natural daylight contribution. Optimise energy savings in cellular ofices and meeting rooms. The occupant chooses when the lights are on; the system ensures they are switched off when the space is vacated. Sensors initiate dimming, saving energy and delivering a constant luminance at the desk. 07 • Fast, easy installation. Snap on / plug in • Fully addressable and PC reconigurable • Analogue, DSI and DALI control • Comprehensive range of energy saving switching, sensing and scheduling devices available • Seamless connectivity with KNX devices from close to 300 manufacturers • Interface with other building control systems via the open KNX protocol • Two way communication with DALI, facilitating control and feedback • Traditional emergency lighting test functions • Comprehensive design and commissioning service LTK_Bro_006_007 v1.indd 7 29/08/2012 12:17 The ability to adapt with the b 08 At the Category A stage of an ofice it-out the lighting requirements of the inal tenant are not known. With Lightrak, developers are able to install a cost-effective lighting control solution that is adequate for the client attraction phase, but can be upgraded to meet the needs of the incoming tenant with a minimum level of investment in time and labour. LTK_Bro_008_009 v3.indd 8 30/08/2012 16:19 e building throughout its life 09 With a matrix of Buscom trunking installed, a Lightrak installation provides a future proof solution where lighting schemes can be completely reconigured without the need to run or terminate any additional cables. Lighting control units are simply unplugged, moved and reprogrammed; additional devices and control units can also be added to extend the capability of any installation. LTK_Bro_008_009 v3.indd 9 30/08/2012 16:19 Lightrak ... ® seamless integration with your technology of choice The Lightrak system operates over a KNX backbone. This enables all control devices connected to the system to communicate with each other, and facilitates seamless interoperability with any KNX certified product. KNX PROTOCOL SYSTEMS KNX is the worldwide standard for all applications in home and building control, ranging from lighting and shutter control to security, HVAC, metering and energy management. With close to 300 members and approximately 7000 certified product ranges, the KNX Association holds partnership agreements with over 30,000 installer companies in over 100 countries. All products bearing the KNX logo are certified in order to guarantee system compatibility, interworking and interoperability and are commissioned via a single, manufacturer independent design and commissioning tool. LEFT: KNX was used as the underlying technology at Terminal 5, Heathrow... possibly the largest lighting control installation in Europe 10 KNX IS APPROVED AS: ENERGY SAVING Lighting accounts for up to 40% of a commercial building’s electricity use. • European Standard (CENELEC EN 50090 and CEN EN 13321-1) • International Standard (ISO/IEC 14543-3) (Lighting Industry Federation) Lighting controls can provide energy savings of 30% to 55%. energy saving LTK_Bro_010_011 v1.indd 10 For more information about KNX, visit: www.knx.org 29/08/2012 12:18 DALI: DIGITAL LIGHTING CONTROL DALI (Digital Addressable Lighting Interface) is a protocol dedicated purely to lighting control, as set out in the technical standard IEC 62386. Each unit in a DALI network has its own address, allowing direct communication with each individual itting. DALI FEATURE IMAGE TECHNICAL FEATURES The information low with DALI is bi-directional. Rather than only giving commands about the light level from the control system to the itting, DALI also enables information feedback on the condition of the ittings. The itting can transmit information related to: • whether the light is switched on or off • the preset light level • the ballast condition Therefore DALI is ideal for use with building automation systems where remote supervising and service reports are required. 11 DELIVERING DALI EMERGENCY FEEDBACK The DALI lighting control unit (LCU) incorporates a KNX to DALI interface that enables full DALI control in addressable mode, and also facilitates the feedback from the DALI network back onto the KNX bus. Utilising widely available KNX gateways, this DALI feedback can then be fed into building management systems (BMS) or other monitoring and reporting software, allowing emergency lighting test data to be logged and alarms raised should essential maintenance be required. For more information about DALI, visit: www.dali-ag.org LTK_Bro_010_011 v1.indd 11 29/08/2012 12:18 The simple way to instant energy savings Combining lighting management sensors with traditional light switches puts users in complete control. Lights can be manually switched on and off or, if users forget to switch off lights, the sensors will do so automatically. EVEN GREATER SAVINGS Independent research shows that the added control available through using absence detection can provide an additional 10% energy saving over and above the significant savings already offered by presence detection. IN DARKNESS Users feel in complete control by turning on lights using a traditional switch, typically located by the door IN BRIGHT LIGHT The sensor will automatically switch off lights to save energy when available light is sufficient (although lights can still be switched on if preferred)* IN NORMAL LIGHT IN WEAK LIGHT The sensor will automatically switch on lights when movement is detected and available light is insufficient* When leaving the room, lights can be manually turned off using a switch. If lights are not turned off, the occupancy sensor will do so automatically 12 ENERGY SAVING Lighting controls are eligible for 100% Enhanced Capital Allowance under the Carbon Trust administered scheme. energy saving * Lux levels can be set according to user preferences LTK_Bro_012_013 v2.indd 12 30/08/2012 09:51 THE RIGHT TECHNOLOGY FOR EVERY ENVIRONMENT Legrand lighting management solutions are available in three different technologies to provide effective occupancy detection in different environments... all of which can be controlled and commissioned remotely at the touch of a button. For small, enclosed spaces PIR sensors detect occupancy using the heat difference between people and the ambient space. For large spaces and open areas Ultrasonic sensors transmit sound waves throughout an area and measure the speed at which they come back. For spaces with low or infrequent movement from occupants Dual technology, as the name suggests, combines both infra-red and ultrasonic detection. 13 REMOTE CONFIGURATORS FOR INSTANT PROGRAMMING OF EACH SENSOR Sensors can be quickly and easily re-configured at the touch of a button, and without the need to ever remove the sensors from the ceiling... putting users in complete control and reducing health and safety risks. • Advanced commissioning tool with LCD display - Precise digital programming - Instant visibility of individual sensor settings - PIR / ultrasonic priority preferences for dual technology sensors • Basic commissioning tool - Pre-programmed settings Save time. Save money. And, of course, save energy. LTK_Bro_012_013 v2.indd 13 30/08/2012 09:22 Legrand... supporting you from initial design through installation and beyond DEDICATED DESIGN TEAM Lighting control units can either be supplied unprogrammed for third party system integration, or complete with a full in-house project design and commissioning service. Our experienced team provides support at all stages of a project, from the outline brief through to inal site commissioning. Sales engineers work with designers at the early stages of a project to recommend optimum Buscom layouts and lighting control options. This service is backed by a specialist support team who are on hand to work with clients to complete detailed design schemes and provide full support through the installation phase. BESPOKE SOLUTIONS Every project is unique and sets its own challenges. Our bespoke product development service enables us to provide solutions to these challenges, and has delivered tailor-made lighting control installations in a wide range of building developments, including: Terminal 5, Heathrow, London Underground, Canary Wharf and Central Bank of Kuwait. 14 LTK_Bro_014_015 v1.indd 14 29/08/2012 12:19 TRUSTED THOUGHOUT THE UK AND ACROSS THE WORLD LIGHTRAK PROJECTS • Royal Bank of Scotland – Delhi, India • Fidelity Investments – Delhi, India • Cyprus Postal Service – Nicosia, Cyprus • 2 x ITTL Showrooms – Nicosia, Cyprus • Barclays Bank – Pane, India • UKPS – Liverpool, England • Lloyds TSB Bank – Old Broad Street, London, England • Bridgewater Place, Mixed use Development – Leeds, England • Lloyds TSB Card Contact Centre Petriies, Scotland • Gray’s School of Art - Robert Gordon University, Aberdeen, Scotland • Rolls Royce - Glasgow, Scotland • Liverpool School of Tropical Medicine Ofice and Labs – University of Liverpool, England • Quorum Business Park, Ofice Development (16 Buildings) - Newcastle upon Tyne, England • Mann Island, Ofice Development – Liverpool, England • Rotherham Civic Quarters, Local Government Ofices - Rotherham, England • First Street Manchester, Manchester City Council - England • Velocity Buildings, Ofice Development Brooklands, Surrey, England • Broadgate West, Ofice Development – London, England • Abbey Gardens, Ofice Development Reading, England • HSE – Dublin, Ireland • KPMG – Manchester, England • KPMG – Watford, England • Rackspace Data Centre – Slough, England • Translational Research Building – Newcastle University, England • Shadon House Care Facility – Gateshead, England 15 LTK_Bro_014_015 v1.indd 15 29/08/2012 12:20 Lightrak® KNX lighting control system system components, lighting control units (LCUs) and sub-cabling to luminaires Feed unit Buscom mounting power supply unit See p. 28-29 Luminaire sub cabling FFA010 - - -/- - - FFE115 Timed event controller Powered line coupler FFA004 FFA008 Lighting control unit FFD060 Dimensions and technical information (p. 19-23) Proprietory lighting control system to work alongside Electrak’s 25 and 40 A buscom trunking with integral communications bus Offers high speed installation and unrivaled flexibility for future reconfiguration. PC configurable, covers all lighting control requirements Based on the KNX open protocol and compatible with 1-10 V, DSI and DALI lighting installations Designed and manufactured in the UK from robust galvanised steel Pack Cat. Nos. System components 1 1 1 1 1 1 1 1 FFA001 FFA004 FFA006 FFA008 FFA010 FFA012 FFA014 FFA016 Statutory warning plaque Timed event controller (flush) Timed event controller (surface) Powered line coupler Buscom mounting power supply unit Line power supply KNX signal cable – 100 m USB to KNX interface Lighting control units (LCUs) – 9 outputs (fully addressable) 1 1 1 1 1 FFD054 FFD054B1 FFD054B2 FFD054B3 FFD055 Analogue dimming (1-10 V) Buscom mounting (standard buscom) L1 Key ‘B’ buscom mounting (3 phase buscom) L2 Key ‘B’ buscom mounting (3 phase buscom) L3 Key ‘B’ buscom mounting (3 phase buscom) Rewirable surface mounting 1 1 1 1 1 FFD056 FFD056B1 FFD056B2 FFD056B3 FFD057 Digital dimming (DSI) Buscom mounting (standard buscom) L1 Key ‘B’ buscom mounting (3 phase buscom) L2 Key ‘B’ buscom mounting (3 phase buscom) L3 Key ‘B’ buscom mounting (3 phase buscom) Rewirable surface mounting FFD060 FFD060B1 FFD060B2 FFD060B3 FFD061 DALI (digital addressable lighting interface) Buscom mounting (standard buscom) L1 Key ‘B’ buscom mounting (3 phase buscom) L2 Key ‘B’ buscom mounting (3 phase buscom) L3 Key ‘B’ buscom mounting (3 phase buscom) Rewirable surface mounting NEW 1 1 1 1 1 Pack Cat. Nos. Sub-cabling to luminaires 1 FFE080 Plugs only 6 pole rewirable plug (male) 1 1 1 1 1 FFE085 FFE095 FFE115 FFE135 FFE120 1 FFE125 Pre-wired plugs and leads (5 m LSOH) With 6 pole male plug to free end – 5 core With 6 pole male plug to free end – 6 core With 6 pole male plug to 6P female plug – 6 core With 6 pole male plug to 4P female plug – 4 core With 6 pole male plug to free end – 3 core no dimming With 6 pole male plug to free end – 4 core no dimming 16 LTK_Bro_016_017 v4.indd 16 22/08/2012 15:31 Lightrak® KNX lighting control system standard switching devices Lighting control unit - - -/- - - See p. 16 Multi-gang switch interface - - -/- - - FFB020 4 gang switch FFB022-4 Presence detector 1 gang switch 1 gang key switch FFC047 FFB030 FFB032 Dimensions and technical information (p. 19-23) Standard switching devices connect into the system via simple CAT 5 cabling either straight into a lighting control unit or into a multi-gang switch interface. The inputs of the control units are addressable and can be commissioned to control any output or group of outputs throughout the entire KNX network. Future layout changes can be accommodated easily as all control units are plug and play and can be re-commissioned through KNX ETS software Pack Cat. Nos. Standard presence detector 1 FFC047 Plug into lighting control unit Presence detector Pack Cat. Nos. CAT 5 cabling to switching devices 1 1 FFF205 FFF210 5 m CAT 5 lead – plug to plug 10 m CAT 5 lead – plug to plug Switches Switches for 1 gang back box 1 1 1 1 FFB030 FFB032 FFB033 FFB034 Plug into lighting control unit (see p. 16) 1 gang switch 1 gang key switch 1 gang key switch – surface (including back box) 2 gang switch Switches for 2 gang back box 1 1 1 FFB022-2 FFB022-3 FFB022-4 Plug into multi-gang switch interface (Cat. No. FFB020) 2 gang switch 3 gang switch 4 gang switch Switches for 2 x 2 gang back box 1 1 1 1 FFB024-5 FFB024-6 FFB024-7 FFB024-8 Plug into multi-gang switch interface (Cat. No. FFB020) 5 gang switch 6 gang switch 7 gang switch 8 gang switch Multi-gang switch interface 1 FFB020 Buscom mounted multi-gang switch interface Back boxes 1 1 1 FFB036 FFB026 FFB028 1 gang 2 gang 2 x 2 gang 17 LTK_Bro_016_017 v4.indd 17 22/08/2012 15:32 Lightrak KNX lighting control system ® NEW 2013 able i a Av l sub-bus addressable devices FFC020 FFC058 FFC055 FFC052 FFC021 FFC050 FFC023 FFC059 FFC024 Technical information (p. 21) Addressable sensing and switching devices can be connected in series on a sub-bus Each sub-bus connects onto the KNX network via a sub-bus to KNX interface unit The addressable sensors offer a higher level of capability and functionality : • Factory set to presence mode, absence mode activated by commissioning tool • Factory pre-set light level threshold 500 lux for false ceiling, 300 lux for surface mounting / flush mounting detectors • Factory pre-set time delay 15 minutes • Precise adjustment on-site via commissioning tool Devices can be commissioned to control any output or group of outputs throughout the entire KNX network. Future layout changes can be accommodated easily as all devices can be re-commissioned through KNX ETS software Pack Cat. Nos. Sub-bus to KNX interface unit 1 FFC020 Buscom mounting interface unit Cat. Nos. Sub-bus sensor – for corridors FFC057 Connects into interface unit (Cat. No. FFC020) With absence and presence modes Includes 10 m connection lead Maximum range 30 m – IP 42 PIR sensor 140° Sub-bus sensors – ceiling mounting IR remote control Connect into interface unit (Cat. No. FFC020) With absence and presence modes Includes 5 m connection lead FFC058 For sub-bus sensors (client use) On / off – dimming controller Pack Sub-bus sensors – commissioning tool 1 FFC021 Digital hand-held commissioning tool 1 1 Other sub-bus devices PIR sensor 1 1 FFC050 FFC051 Detection field 45 m2 – Ø 8 m Optimum distance between detectors : 6 m PIR ceiling mounting switch sensor 360° Surface mounting box for FFC050 Combined PIR and ultrasonic sensor 1 1 FFC052 FFC053 Light measurement cell 1 FFC059 Sub-bus switches Detection field 90 m2 – Ø 11 m Optimum distance between detectors : 10 m PIR and ultrasonic ceiling mounting sensor 360° Surface mounting box for FFC052 Sub-bus sensors – wall mounting 1 FFC030 FFC033 Connect into interface unit (Cat. No. FFC020) Includes 10 m connection lead Complete with brushed stainless steel plate, yolk and magnesium rockers 2 gang 2 way sub-bus switch 4 scenario sub-bus switch 1 1 1 FFC022 FFC023 FFC024 Sub-bus cable – 100 m RJ45 doubler unit to extend sub-bus Sub-bus to RJ45 connector 1 Connect into interface unit (Cat. No. FFC020) With absence and presence modes Includes 10 m connection lead PIR sensor 1 FFC054 Maximum range 8 m – IP 42 PIR wall mounting sensor 180° Connects into interface unit (Cat. No. FFC020) Includes 5 m lead Photocell light level sensor Sub-bus accessories Combined PIR and ultrasonic sensor 1 FFC055 Maximum range 11 m – IP 42 PIR and ultrasonic wall mounting sensor 180° IP 55 sensor 1 FFC056 Maximum range 15 m – IP 55 PIR wall mounting sensor 270° 18 LTK_Bro_018 v4.indd 18 22/08/2012 15:37 Lightrak® KNX lighting control system technical information n KNX technical specification n Buscom trunking mounted power supply unit FFA010 Each line coupler can support 64 bus devices (lighting control units, multi-gang switch interface units, bus interface units etc) A maximum of 15 line couplers may be linked with a main bus line together to form an area; therefore an area can support up to 960 devices The system may be further expanded with the addition of a backbone bus line which would allow the linking together of 15 main bus lines via 15 line couplers, therefore any single system could support 14 400 devices By utilising additional line couplers this total can exceed 64 000 devices (for additional information, please contact us on +44 (0) 845 600 6266) Connections • 230 V : Electrak integrated tap-off • Bus : Electrak integrated tap-off Physical specifications • Housing : galvanised steel, natural finish • Dimensions : length 330 mm, width 110 mm, height 60 mm 9 mm bracket clearance from busbar trunking • Weight : approximately 1·90 kg Technical specifications Supply voltage : 230 V 50/60 Hz Protection (supply) : 13 A BS 1362 fuse fitted in tap-off Internal protection : 6·3 A fuse to IEC 127-2 Secondary output voltage : 30 Vdc +/- 2 V Secondary output current : 640 mA Tap-off ASTA approved : BS EN 60439-2 : 2000 EMC complies with : EN 50090-2-2 :1997, EN 55022B Climatic condition class : 3K4 (5ºC to 40ºC) IP rating : 4x Certification : KNX certified Within any KNX bus line the following cable lengths are permitted : • Power supply unit to bus device 350 m maximum • Bus device to bus device 700 m maximum • Total bus line length 1 000 m maximum • Minimum distance between 2 power supply units on one line is 200 m(1) n Powered line coupler FFA008 Connections • 230 V : screw connection block • Primary line : screw connection block • Secondary line : screw connection block Physical specifications • Housing : galvanised steel, natural finish • Dimensions : length 358 mm, width 200 mm, depth 75 mm • Weight : approximately 2·750 kg Technical specifications Supply voltage : 230V 50/60Hz Protection (supply) : 13 A BS 1362 fused spur Internal protection : 6·3 A fuse to IEC127-2 Primary line load : 15 mW Secondary line load : 200 mW Secondary output voltage : 30Vdc +/- 2 V Secondary output current : 630 mA EMC complies with : EN 50090-2-2 : 1997, EN 55022B Climatic condition class : 3K4 (5ºC to 40ºC) IP rating : 4x Certification : KNX certified ± ± (1) Electrak manufacture a buscom trunking mounted power supply unit for this application, Cat. No. FFA010 see p. 16 ± ± n Line power supply FFA012 Connections • 230 V : screw connection block • Bus : screw connection block Physical specifications • Housing : galvanised steel, natural finish • Dimensions : length 358 mm, width 110 mm, depth 75 mm • Weight : approximately 1·95 kg Technical specifications Supply voltage : 230 V 50/60Hz Protection (supply) : 13 A BS 362 fused spur Internal protection : 6·3 A fuse to IEC 127-2 Secondary output voltage : 30 Vdc +/- 2 V Secondary output current : 640 mA EMC complies with : EN 50090-2-2 : 1997, EN 55022B Climatic condition class : 3K4 (5ºC to 40ºC) IP rating : 4x Certification : KNX certified ± ± All dimensions (mm) are nominal 19 LTK_Bro_019_023 v4.indd 19 23/08/2012 13:55 Lightrak® KNX lighting control system technical information n Lighting control unit – analogue dimming Cat. Nos. FFD054/FFD055 Connections • 4 RJ45 inputs : CAT 5 providing switching input • 9 GST/6 providing 230 V to luminaires L1 Switched live brown E Earth green / yellow N Neutral blue L2 Maintained live black 2 Dimming common white 3 Dimming red Physical specifications • Housing : galvanised steel, natural finish • Dimensions : length 358 mm, width 182 mm, depth 35 mm plus 9 mm bracket clearance from buscom trunking • Weight : approximately 1·75 kg Technical specifications Supply voltage : 230 V 50/60Hz Maximum load : 10 A BS 1362 fuse fitted in tap-off Maximum power : 2 300 VA Bus voltage : 30 Vdc +/- 2 V Tap-off ASTA approved : BS EN 60439-2 : 2000 EMC complies with : EN 50090-2-2 : 1997 Climatic condition class : 3K4 (5ºC to 40ºC) IP rating : 4x Certification : KNX certified ± ± n Lighting control unit – DSI dimming Cat. Nos. FFD056/ FFD057 Connections • 4 RJ45 inputs : CAT 5 providing switching input • 9 GST/6 providing 230 V to luminaires L1 Switched live brown E Earth green / yellow N Neutral blue L2 Maintained live black 2 Dimming common white 3 Dimming red Physical specifications • Housing : galvanised steel, natural finish • Dimensions : length 358 mm, width 182 mm, depth 35 mm plus 9 mm bracket clearance from buscom trunking • Weight : approximately 1·75 kg Technical specifications Supply voltage : 230 V 50/60 Hz Maximum load : 10 A BS 1362 fuse fitted in tap-off Maximum power : 2 300 VA Bus voltage : 30 Vdc +/- 2 V Tap-off ASTA approved : BS EN 60439-2 : 2000 EMC complies with : EN 50090-2-2 : 1997 Climatic condition class : 3K4 (5ºC to 40ºC) IP rating : 4x Certification : KNX certified ± ± n 4 gang switch Cat. No. FFB022-4 Physical specifications • Housing : steel back box 132 mm x 72 mm minimum 48 mm deep • Dimensions : length 125 mm, width 64 mm, height 41 mm • Weight : approximately 0·668 kg Technical specifications Supply voltage : 9 Vdc EMC complies with : EN 50090-2-2 : 1997 Climatic condition class : 3K4 (5ºC to 40ºC) IP rating : 4x Certification : KNX certified n 8 gang switch Cat. No. FFB024-8 Physical specifications • Housing : steel back box 136 mm x 136 mm minimum 52 mm deep • Dimensions : length 127 mm, width 122 mm, height 41 mm • Weight : approximately 1·30 kg Technical specifications Supply voltage : 9 Vdc EMC complies with : EN 50090-2-2 : 1997 Climatic condition class : 3K4 (5ºC to 40ºC) IP rating : 4x Certification : KNX certified n Multi-gang switch interface Cat. No. FFB020 Connections • 230 V : Electrak integrated tap-off • Bus : Electrak integrated tap-off • Switch : CAT 5 lead (RJ45 to RJ45) Physical specifications • Housing : galvanised steel, natural finish • Dimensions : length 126 mm, width 102 mm, height 46 mm plus 9 mm mounting bracket • Weight : approximately 0·66 kg Technical specifications Supply voltage : 230 V 50/60 Hz Protection : 3 A BS 1362 fuse fitted in tap-off Nominal load : 24 mA Maximum bus load : 12 mA Tap-off ASTA approved : BS EN 60439-2 : 2000 EMC complies with : EN 50090-2-2 : 1997 Climatic condition class : 3K4 (5ºC to 40ºC) IP rating : 4x Certification : KNX certified ± ± n Lighting control unit – dimensions Cat. Nos. FFD054, FFD056, FFD060 n Lighting control unit – DALI Cat. Nos. FFD060/FFD061 Connections • 4 RJ45 inputs : CAT 5 providing switching input • 9 GST/6 providing 230 V to luminaires L1 Switched live brown E Earth green / yellow N Neutral blue 2 DALI 3 DALI Physical specifications • Housing : galvanised steel, natural finish • Dimensions : length 358 mm, width 182 mm, depth 35 mm plus 9 mm bracket clearance from buscom trunking • Weight : approximately 1·75 kg Technical specifications Supply voltage : 230 V 50/60 Hz Maximum load : 10 A Maximum power : 2 300 VA KNX bus voltage : 30 Vdc +/- 2 V Tap-off ASTA approved : BS EN 60439-2 : 2000 EMC complies with : EN 50090-2-2 : 1997 Climatic condition class : 3K4 (5ºC to 40ºC) IP rating : 4x ± ± All dimensions (mm) are nominal 20 LTK_Bro_019_023 v4.indd 20 22/08/2012 16:06 Lightrak® KNX lighting control system sub-bus sensors technical information n Ceiling mounting All sub-bus sensors have built-in bracket systems that enable ceiling mounting. Most sensors are suitable for standard EU boxes (Ø 65). This is important for applications where the ceiling is unavailable for sensor installation. Only one Cat. No. is required for two ways of mounting n Sub-bus to KNX interface unit FFC020 Connections • Bus : Electrak integrated tap-off connecting 230 V and KNX bus Physical specifications • Housing : galvanised steel, natural finish • Dimensions : length 125 mm, width 154 mm, height 72 mm plus 9 mm mounting bracket Technical specifications Supply voltage : 230 V 50/60 Hz Protection : 3 A BS 1362 fuse fitted in tap-off Tap-off ASTA approved : BS EN 60439-2 : 2000 EMC complies with : EN 50090-2-2 : 1997 Climatic condition class : 3K4 (5ºC to 40ºC) IP rating : 4x Certification : KNX certified ± ± n Wall mounting Wall mounting sensors are supplied with mounting base Simply ix base to the wall, connect wires to the automatic wiring block and ix sensor to base n Settings Most sensors feature Smart Factory Set technology. Adjustments are typically not needed after installation If adjustments need to be made (due to last minute changes in furniture or ixture placement), sensitivity and time delays should match the activity levels of the monitored spaces Hand-held commissioning tool can be used to adjust settings : This commissioning tool enables a very precise commissioning of your sensors : - Time: from 0 seconds to 60 min - Lux: from 1 lux to 1 275 lux - Detection mode : presence, presence walkthrough, absence modes - PIR and US detection sensibility : low, medium, high, very high - Provides access to advanced functions such as calibration, alarms, choice of mode of detection (initial detection, maintain detection, retrigger), daylight function - Allows downloading, saving and duplication of sensor parameters Cat.No FFC021 Presence mode 3' Walkthrough mode Absence mode 21 LTK_Bro_019_023 v4.indd 21 23/08/2012 13:56 Lightrak® KNX lighting control system typical layout and system topology n KNX system topology schematic diagram Bus line (max. 64 LCU) Bus line (max. 64 LCU) Example of typical layout Repeater power line coupler 1.5.64 Main line powered line coupler 1.5.128 KNX standard bus cable 1.1 .0 1.2.0 1.3.0 1.4.0 1.5.0 AREA 1 main bus line 1.5.192 (maximum) 1.15.0 (maximum) KNX standard bus cable interconnecting main line powered line coupler AREA 2 main bus line AREA 3 main bus line AREA 4 main bus line Backbone powered line coupler 1.0. – AREA 15 main bus line (maximum) 1.0.1 Backbone power supply unit 1.0.2 1.0.3 1.0.4 1.0.15 Backbone bus line KNX standard bus cable interconnecting backbone powered line coupler n Example of ceiling layout for Lightrak KNX fully addressable system (see opposite) Layout key Electrical distribution board and power cabling Powered line coupler and KNX cabling Timed event controller Buscom feed unit and lengths 1/1 Lighting control unit and reference number Luminaires and sub-cabling Standard presence detector and CAT 5 sub cabling Sub-bus interface unit and sub-bus cabling PIR bus sensor Dual technology (PIR and ultrasonic) bus sensor Bus switch Bus scenario switch 22 LTK_Bro_019_023 v4.indd 22 23/08/2012 14:39 Cat A lighting layout 1/2 5/2 2/2 4/2 3/2 5/1 4/1 3/1 1/1 2/1 6/2 6/1 The left hand area fitted out to Cat B tenant layout 1/5 2/5 3/3 5/2 1/4 4/2 2/4 3/2 1/3 2/3 5/1 1/2 4/1 2/2 3/1 1/1 2/1 6/1 6/2 23 LTK_Bro_019_023 v4.indd 23 22/08/2012 17:47 ® pour exemple XXXXXXxxxxxx Electrak buscom trunking xxxxxxxx 2P, 3P, dual circuit and 3 phase systems SYSTEM IP RATING RATING 3 m track 0·5 m spacings 2 m track 0·5 m spacings 3 m track 1·0 m spacings 2 m track 1·0 m spacings Single sided BBA3145C BBA2145C BBA3141C BBA2141C Double sided BBA3245C BBA2245C BBA3241C BBA2241C Single sided CCA3145C CCA2145C CCA3141C CCA2141C Double sided CCA3245C CCA2245C CCA3241C CCA2241C Single sided BBA3155C BBA2155C BBA3151C BBA2151C Double sided BBA3255C BBA2255C BBA3251C BBA2251C Single sided CCA3155C CCA2155C CCA3151C CCA2151C Double sided CCA3255C CCA2255C CCA3251C CCA2251C Single sided BBB3145C BBB2145C BBB3141C BBB2141C Double sided BBB3245C BBB2245C BBB3241C BBB2241C Single sided CCB3145C CCB2145C CCB3141C CCB2141C Double sided CCB3245C CCB2245C CCB3241C CCB2241C Single sided BBB3155C BBB2155C BBB3151C BBB2151C Double sided BBB3255C BBB2255C BBB3251C BBB2251C Single sided CCB3155C CCB2155C CCB3151C CCB2151C Double sided CCB3255C CCB2255C CCB3251C CCB2251C Single sided BBC3145C BBC2145C BBC3141C BBC2141C Double sided BBC3245C BBC2245C BBC3241C BBC2241C Single sided CCC3145C CCC2145C CCC3141C CCC2141C Double sided CCC3245C CCC2245C CCC3241C CCC2241C Single sided BBC3155C BBC2155C BBC3151C BBC2151C Double sided BBC3255C BBC2255C BBC3251C BBC2251C Single sided CCC3155C CCC2155C CCC3151C CCC2151C Double sided CCC3255C CCC2255C CCC3251C CCC2251C Single sided BBD3145C BBD2145C BBD3141C BBD2141C Double sided BBD3245C BBD2245C BBD3241C BBD2241C Single sided CCD3145C CCD2145C CCD3141C CCD2141C Double sided CCD3245C CCD2245C CCD3241C CCD2241C Single sided BBD3155C BBD2155C BBD3151C BBD2151C Double sided BBD3255C BBD2255C BBD3251C BBD2251C Single sided CCD3155C CCD2155C CCD3151C CCD2151C Double sided CCD3255C CCD2255C CCD3251C CCD2251C OUTLETS 25 A IP 4X 40 A Electrak 30 2P + E system 25 A IP 54 40 A 25 A IP 4X 40 A Electrak 31 3P + E system 25 A IP 54 40 A 25 A IP 4X 40 A Electrak 32 Dual circuit system 25 A IP 54 40 A 25 A IP 4X 40 A Electrak 33 3 phase system 25 A IP 54 40 A 24 LTK_Bro_024_025 v2.indd 24 22/08/2012 16:16 Centre feed Suspended feed Suspended feed unit left hand unit right hand Surface feed unit left hand Surface feed unit right hand Suspended flexible corner 0·5 m Suspended flexible corner 2·0 m Surface flexible corner 0·5 m Surface flexible corner 2·0 m BBA44FC BBA14LFC BBA14RFC BBA34LFC BBA34RFC BBA140XC BBA142XC BBA340XC BBA342XC – BBA24LFC BBA24RFC – – BBA240XC BBA242XC – – CCA44FC CCA14LFC CCA14RFC CCA34LFC CCA34RFC CCA140XC CCA142XC CCA340XC CCA342XC – CCA24LFC CCA24RFC – – CCA240XC CCA242XC – – – BBA15LFC BBA15RFC BBA35LFC BBA35RFC BBA150XC BBA152XC BBA350XC BBA352XC – BBA25LFC BBA25RFC – – BBA250XC BBA252XC – – – CCA15LFC CCA15RFC CCA35LFC CCA35RFC CCA150XC CCA152XC CCA350XC CCA352XC – CCA25LFC CCA25RFC – – CCA250XC CCA252XC – – BBB44FC BBB14LFC BBB14RFC BBB34LFC BBB34RFC BBB140XC BBB142XC BBB340XC BBB342XC – BBB24LFC BBB24RFC – – BBB240XC BBB242XC – – CCB44FC CCB14LFC CCB14RFC CCB34LFC CCB34RFC CCB140XC CCB142XC CCB340XC CCB342XC – CCB24LFC CCB24RFC – – CCB240XC CCB242XC – – – BBB15LFC BBB15RFC BBB35LFC BBB35RFC BBB150XC BBB152XC BBB350XC BBB352XC – BBB25LFC BBB25RFC – – BBB250XC BBB252XC – – – CCB15LFC CCB15RFC CCB35LFC CCB35RFC CCB150XC CCB152XC CCB350XC CCB352XC – CCB25LFC CCB25RFC – – CCB250XC CCB252XC – – BBC44FC BBC14LFC BBC14RFC BBC34LFC BBC34RFC BBC140XC BBC142XC BBC340XC BBC342XC – BBC24LFC BBC24RFC – – BBC240XC BBC242XC – – CCC44FC CCC14LFC CCC14RFC CCC34LFC CCC34RFC CCC140XC CCC142XC CCC340XC CCC342XC – CCC24LFC CCC24RFC – – CCC240XC CCC242XC – – – BBC15LFC BBC15RFC BBC35LFC BBC35RFC BBC150XC BBC152XC BBC350XC BBC352XC – BBC25LFC BBC25RFC – – BBC250XC BBC252XC – – – CCC15LFC CCC15RFC CCC35LFC CCC35RFC CCC150XC CCC152XC CCC350XC CCC352XC – CCC25LFC CCC25RFC – – CCC250XC CCC252XC – – BBD44FC BBD14LFC BBD14RFC BBD34LFC BBD34RFC BBD140XC BBD142XC BBD340XC BBD342XC – BBD24LFC BBD24RFC – – BBD240XC BBD242XC – – CCD44FC CCD14LFC CCD14RFC CCD34LFC CCD34RFC CCD140XC CCD142XC CCD340XC CCD342XC – CCD24LFC CCD24RFC – – CCD240XC CCD242XC – – – BBD15LFC BBD15RFC BBD35LFC BBD35RFC BBD150XC BBD152XC BBD350XC BBD352XC – BBD25LFC BBD25RFC – – BBD250XC BBD252XC – – – CCD15LFC CCD15RFC CCD35LFC CCD35RFC CCD150XC CCD152XC CCD350XC CCD352XC – CCD25LFC CCD25RFC – – CCD250XC CCD252XC – – 25 LTK_Bro_024_025 v2.indd 25 22/08/2012 16:16 ® pour exemple XXXXXXxxxxxx Electrak buscom trunking xxxxxxxx tap-offs Rewirable 0·8 m 2m 3m 5m – DDE408FC DDE42FC DDE43FC DDE45FC DDF4F DDE408F DDE42F DDE43F DDE45F IP RATING PHASE With comms L+ N Electrak 30 2P + E system SYSTEM 13 A FUSED TAP-OFFS IP 4X No comms With comms – DDE508FC DDE52FC DDE53FC DDE55FC DDF5F DDE508F DDE52F DDE53F DDE55F – DDE408FC DDE42FC DDE43FC DDE45FC IP 54 No comms With comms L1 N No comms With comms No comms With comms No comms With comms DDE42F DDE43F DDE45F DDE508FC DDE52FC DDE53FC DDE55FC DDF5F DDE508F DDE52F DDE53F DDE55F – DDG408FC DDG42FC DDG43FC DDG45FC L1 N1 DDH4F DDG408F DDG42F DDG43F DDG45F – DDG508FC DDG52FC DDG53FC DDG55FC DDH5F DDG508F DDG52F DDG53F DDG55F – DDE408FC DDE42FC DDE43FC DDE45FC IP 54 With comms IP 4X No comms With comms DDF4F DDE408F DDE42F DDE43F DDE45F – DDE508FC DDE52FC DDE53FC DDE55FC DDF5F DDE508F DDE52F DDE53F DDE55F – DDJ408FC DDJ42FC DDJ43FC DDJ45FC IP 54 No comms With comms L2 N2 Electrak 32 DDE408F – IP 4X No comms Dual circuit system DDF4F IP 54 L1 L2 N Electrak 31 3P + E system IP 4X IP 4X No comms With comms DDK4F DDJ408F DDJ42F DDJ43F DDJ45F – DDJ508FC DDJ52FC DDJ53FC DDJ55FC DDK5F DDJ508F DDJ52F DDJ53F DDJ55F IP 54 No comms With comms L1 N IP 4X No comms With comms IP 54 No comms L2 N With comms IP 4X With comms No comms With comms DDM408L1FC DDM42L1FC DDM43L1FC DDM45L1FC DDM408L1F DDM42L1F DDM43L1F DDM45L1F – DDM508L1FC DDM52L1FC DDM53L1FC DDM55L1FC DDN5L1F DDM508L1F DDM52L1F DDM53L1F DDM55L1F – DDM408L2FC DDM42L2FC DDM43L2FC DDM45L2FC DDN4L2F DDM408L2F DDM42L2F DDM43L2F DDM45L2F – DDM508L2FC DDM52L2FC DDM53L2FC DDM55L2FC DDN5L2F DDM508L2F DDM52L2F DDM53L2F DDM55L2F – DDM408L3FC DDM42L3FC DDM43L3FC DDM45L3FC DDN4L3F DDM408L3F DDM42L3F DDM43L3F DDM45L3F – DDM508L3FC DDM52L3FC DDM53L3FC DDM55L3FC DDN5L3F DDM508L3F DDM52L3F DDM53L3F DDM55L3F – – – – – DDP4SF – – – – – – – – – L3 N IP 4X No comms With comms IP 54 No comms L+L+L+N Phase selectable Electrak 33 IP 54 3 phase system No comms – DDN4L1F With comms IP 4X No comms With comms IP 54 DDP5SF – – – – With comms No comms – – – – – No comms – – – – – With comms – – – – – No comms – – – – – IP 4X IP 54 26 LTK_Bro_026_027 v2.indd 26 22/08/2012 16:17 16 A UNFUSED TAP-OFFS Rewirable 0·8 m 2m 3m 5m – DDE408C DDE42C DDE43C DDE45C DDF4 DDE408 DDE42 DDE43 DDE45 – DDE508C DDE52C DDE53C DDE55C DDF5 DDE508 DDE52 DDE53 DDE55 – DDE408C DDE42C DDE43C DDE45C DDF4 DDE408 DDE42 DDE43 DDE45 – DDE508C DDE52C DDE53C DDE55C DDF5 DDE508 DDE52 DDE53 DDE55 – DDG408C DDG42C DDG43C DDG45C DDH4 DDG408 DDG42 DDG43 DDG45 – DDG508C DDG52C DDG53C DDG55C DDH5 DDG508 DDG52 DDG53 DDG55 – DDE408C DDE42C DDE43C DDE45C DDF4 DDE408 DDE42 DDE43 DDE45 – DDE508C DDE52C DDE53C DDE55C DDF5 DDE508 DDE52 DDE53 DDE55 – DDJ408C DDJ42C DDJ43C DDJ45C DDK4 DDJ408 DDJ42 DDJ43 DDJ45 – DDJ508C DDJ52C DDJ53C DDJ55C DDK5 DDJ508 DDJ52 DDJ53 DDJ55 – DDM408L1C DDM42L1C DDM43L1C DDM45L1C DDN4L1 DDM408L1 DDM42L1 DDM43L1 DDM45L1 – DDM508L1C DDM52L1C DDM53L1C DDM55L1C DDN5L1 DDM508L1 DDM52L1 DDM53L1 DDM55L1 – DDM408L2C DDM42L2C DDM43L2C DDM45L2C DDN4L2 DDM408L2 DDM42L2 DDM43L2 DDM45L2 – DDM508L2C DDM52L2C DDM53L2C DDM55L2C DDN5L2 DDM508L2 DDM52L2 DDM53L2 DDM55L2 – DDM408L3C DDM42L3C DDM43L3C DDM45L3C DDN4L3 DDM408L3 DDM42L3 DDM43L3 DDM45L3 – DDM508L3C DDM52L3C DDM53L3C DDM55L3C DDN5L3 DDM508L3 DDM52L3 DDM53L3 DDM55L3 – – – – – DDP4S – – – – – – – – – DDP5S – – – – – – – – – – DDR408 DDR42 DDR43 DDR45 – – – – – – DDR508 DDR52 DDR53 DDR55 27 LTK_Bro_026_027 v2.indd 27 22/08/2012 16:17 Electrak® 30 2P + E buscom trunking power and communication distribution CCA3145C CCA2145C CCA14RFC CCA142XC CCA14LFC Selection chart (p. 24-27) Dimensions and technical information (p. 38-43) Integral communication bus suitable for KNX, Lonworks, DALI protocols, etc. 25 A and 40 A systems Outlets on one or two sides. IP 4X or IP 54 ingress protection Fast installation (trunking push fits together in seconds). High quality materials. Suspended or surface mounted Pack Cat. Nos. Electrak 30 2 P + E + comms – single sided system Pack Cat. Nos. 2P + E buscom trunking system with integral communications bus circuit available in IP 4X and IP 54 versions Socket outlets are colour coded white and are located on just one side of the bar 2P + E trunking lengths Trunking lengths push fit into each other, and feed units or flexible lengths. Trunking lengths can be surface mounted or suspended using the various bracket options 1 1 1 1 1 1 1 1 25 A BBA3145C BBA2145C BBA3141C BBA2141C 40 A CCA3145C CCA2145C CCA3141C CCA2141C Length (m) Tap-off outlets Weight (kg)(1) 3 2 3 2 6 4 3 2 4·47 3·27 4·42 3·24 3 2 3 2 6 4 3 2 4·57 3·36 4·52 3·31 C Flexible lengths for single sided system Flexible lengths can be used to change direction, change level or overcome obstructions Suspended – right to left 1 1 1 1 BBA140XC BBA142XC CCA140XC CCA142XC Length (m) Rating (A) Weight (kg)(1) 0·5 2 0·5 2 25 25 40 40 2·91 3·21 2·94 3·33 Surface mounted – right to left 1 1 1 1 BBA340XC BBA342XC CCA340XC CCA342XC Length (m) Rating (A) Weight (kg)(1) 0·5 2 0·5 2 25 25 40 40 2·99 3·05 3·02 3·41 L N PE Feed units for single sided system Feed units come with 2 x 25 mm Ø and 2 x 16 mm Ø cable entry holes and single screw cable terminals for power and data Left feed units are supplied with right end stop Right feed units are supplied with left end stop Centre feed units are supplied with right and left end stops Suspended Weight (kg)(1) 1 1 1 1 BBA14LFC BBA14RFC CCA14LFC CCA14RFC 25 A left 25 A right 40 A left 40 A right 1·22 1·49 1·27 1·49 Surface mounted Weight (kg)(1) 1 1 1 1 BBA34LFC BBA34RFC CCA34LFC CCA34RFC 25 A left 25 A right 40 A left 40 A right 1·31 1·54 1·31 1·54 Centre feed Weight (kg)(1) 1 1 BBA44FC CCA44FC 25 A 40 A 1·8 1·8 (1) Weights shown are for IP 4X rated buscom. For all other weights, contact us on +44 (0) 845 600 6266 Key : How to select the correct components All examples on this page show IP 4X buscom trunking IP rating is dictated by the red letters 4 = IP 4X. For IP 54 version, replace 4 with 5 28 LTK_Bro_028_029 v3.indd 28 23/08/2012 13:58 Electrak® 30 2P + E buscom trunking power and communication distribution CCA3245C CCA2245C DDE45 DDE45C DDF4F Selection chart (p. 24-27) Dimensions and technical information (p. 38-43) Integral communication bus suitable for KNX, Lonworks, DALI protocols, etc. 25 A and 40 A systems Outlets on one or two sides. IP 4X or IP 54 ingress protection Fast installation (trunking push fits together in seconds). High quality materials. Suspended or surface mounted Pack Cat. Nos. Electrak 30 2 P + E + comms – double sided system Pack Cat. Nos. 2P + E buscom trunking system with integral communications bus circuit available in IP 4X and IP 54 versions Socket outlets are colour coded white and are located on both sides of the bar The comms circuit is only available on one side of the bar as shown in the diagram below 2P + E trunking lengths Trunking lengths push fit into each other, and feed units or flexible lengths. Double sided trunking must be fixed using suspended fixing brackets 1 1 1 1 1 1 1 1 25 A BBA3245C BBA2245C BBA3241C BBA2241C 40 A CCA3245C CCA2245C CCA3241C CCA2241C Length (m) Tap-off outlets Weight (kg)(1) 3 2 3 2 11 7 6 4 4·85 3·52 4·70 3·47 3 2 3 2 11 7 6 4 PE N L Pre-wired tap-off units to pick-up L1+N, colour coded white Length (m) 1 1 1 1 DDE408C DDE42C DDE43C DDE45C 5·05 3·65 4·96 3·61 0·8 2 3 5 Fixed polarity Weight (kg)(1) L+N 0·2 0·4 0·5 0·7 13 A fused tap-off units Pre-wired tap-off units to pick-up L1+N, supplied with BS 1362 fuse, colour coded white C L N PE Tap-off units with and without comms Power only tap-offs can plug into any tap-off outlet Tap-offs with comms can only be plugged into the comms side of the bar 16 A unfused tap-off units 1 1 1 1 DDE408FC DDE42FC DDE43FC DDE45FC Length (m) Fixed polarity Weight (kg)(1) 0·8 2 3 5 L+N 0·2 0·4 0·5 0·7 Tap-off units without comms – rewirable 16 A unfused tap-off unit Feed units for double sided system Double sided feed units come with 2 x 25 mm Ø cable entry holes for each side of the bar, plus a further 2 x 16 mm Ø. holes for the comms side of the bar Single screw cable terminals are provided for power and data. Supplied with end stops Rewirable tap-off unit to pick-up L1+N, colour coded white, can plug into any tap-off outlet 1 DDF4 25 A left 25 A right 40 A left 40 A right 1·29 1·51 1·39 1·61 1 Flexible lengths for double sided system Flexible lengths can be used to change direction, change level or overcome obstructions Suspended – right to left 1 1 1 1 BBA240XC BBA242XC CCA240XC CCA242XC Length (m) Rating (A) Weight (kg)(1) 0·5 2 0·5 2 25 25 40 40 3·14 3·67 3·25 3·91 L+N 0·14 Rewirable tap-off unit to pick-up L1+N, supplied with BS 1362 fuse, colour coded white, can plug into any tap-off outlet Weight(kg)(1) BBA24LFC BBA24RFC CCA24LFC CCA24RFC Weight (kg)(1) 13 A fused tap-off unit Suspended 1 1 1 1 Fixed polarity DDF4F Fixed polarity Weight (kg)(1) L+N 0·14 (1) Weights shown are for IP 4X rated buscom. For all other weights, contact us on +44 (0) 845 600 6266 Key : How to select the correct components All examples on this page show IP 4X buscom trunking IP rating and tap-off type is dictated by the red letters 4 = IP 4X. For IP 54 version, replace 4 with 5 C = Tap-off with communications circuit For power only, remove the C 29 LTK_Bro_028_029 v3.indd 29 22/08/2012 16:18 Electrak® 31 3P + E buscom trunking power and communication distribution CCB3145C CCB2145C CCB14RFC CCB142XC CCB14LFC Selection chart (p. 24-27) Dimensions and technical information (p. 38-43) Integral communication bus suitable for KNX, Lonworks, DALI, protocols etc. 25 A and 40 A systems Outlets on one or two sides. IP 4X or IP 54 ingress protection Fast installation (trunking push fits together in seconds). High quality materials. Suspended or surface mounted Pack Cat. Nos. Electrak 31 3P + E – single sided system Pack Cat. Nos. Flexible lengths can be used to change direction, change level or overcome obstructions 3P + E buscom trunking system with integral communications bus circuit available in IP 4X and IP 54 versions Socket outlets are colour coded white and are located on just one side of the bar 3P + E trunking lengths Trunking lengths push fit into each other, and feed units or flexible lengths. Trunking lengths can be surface mounted or suspended using the various bracket options 1 1 1 1 1 1 1 1 25 A BBB3145C BBB2145C BBB3141C BBB2141C 40 A CCB3145C CCB2145C CCB3141C CCB2141C Length (m) Tap-off outlets Weight (kg)(1) 3 2 3 2 6 4 3 2 4·62 3·37 4·58 3·34 3 2 3 2 6 4 3 2 4·77 3·47 4·73 3·44 C L2 L1 N PE Flexible lengths for single sided system Suspended – right to left 1 1 1 1 BBB140XC BBB142XC CCB140XC CCB142XC Length (m) Rating (A) Weight (kg)(1) 0·5 2 0·5 2 25 25 40 40 3·04 3·40 3·08 3·56 Surface mounted – right to left 1 1 1 1 BBB340XC BBB342XC CCB340XC CCB342XC Length (m) Rating (A) Weight (kg)(1) 0·5 2 0·5 2 25 25 40 40 2·99 3·32 3·00 3·48 Feed units for single sided system Feed units come with 2 x 25 mm Ø and 2 x 16 mm Ø cable entry holes and single screw cable terminals for power and data Left feed units are supplied with right end stop Right feed units are supplied with left end stop Centre feed units are supplied with right and left end stops Suspended Weight (kg)(1) 1 1 1 1 BBB14LFC BBB14RFC CCB14LFC CCB14RFC 25 A left 25 A right 40 A left 40 A right 1·25 1·48 1·33 1·55 Surface mounted Weight (kg)(1) 1 1 1 1 BBB34LFC BBB34RFC CCB34LFC CCB34RFC 25 A left 25 A right 40 A left 40 A right 1·29 1·52 1·37 1·59 Centre feed Weight (kg)(1) 1 1 BBB44FC CCB44FC 25 A 40 A 1·8 1·8 (1) Weights shown are for IP 4X rated buscom. For all other weights, contact us on +44 (0) 845 600 6266 Key : How to select the correct components All examples on this page show IP 4X buscom trunking IP rating is dictated by the red letters 4 = IP 4X. For IP 54 version, replace 4 with 5 30 LTK_Bro_030_031 v3.indd 30 23/08/2012 14:05 Electrak® 31 3P + E buscom trunking power and communication distribution CCB3245C CCB2245C DDE45 DDE45C DDH4F Selection chart (p. 24-27) Dimensions and technical information (p. 38-43) Integral communication bus suitable for KNX, Lonworks, DALI protocols, etc. 25 A and 40 A systems Outlets on one or two sides. IP 4X or IP 54 ingress protection Fast installation (trunking push fits together in seconds). High quality materials. Suspended or surface mounted Pack Cat. Nos. Trunking lengths push fit into each other, and feed units or flexible lengths. Double sided trunking must be fixed using suspended fixing brackets 1 1 1 1 Length (m) Tap-off outlets Weight (kg)(1) 3 2 3 2 11 7 6 4 5·15 3·72 5·06 3·68 3 2 3 2 11 7 6 4 5·45 3·92 5·36 3·88 Length (m) 1 1 1 1 1 1 1 1 DDE408C DDE42C DDE43C DDE45C DDG408C DDG42C DDG43C DDG45C PE N L1 L2 C L2 L1 N PE Suspended Weight (kg)(1) 25 A left 25 A right 40 A left 40 A right Length (m) 1 1 1 1 1 1 1 1 DDE408FC DDE42FC DDE43FC DDE45FC DDG408FC DDG42FC DDG43FC DDG45FC 0·8 2 3 5 0·8 2 3 5 Fixed polarity L+N L1 + L2 + N Weight (kg)(1) 0·2 0·4 0·5 0·7 0·2 0·4 0·5 0·7 Tap-off units without comms – rewirable 1 1 DDF4 DDH4 Fixed polarity Weight (kg)(1) L+N L1 L2 N1 0·14 0·14 13 A fused tap-off unit Rewirable tap-off units supplied with BS 1362 fuse, colour coded white, can plug into any tap-off outlet Flexible lengths can be used to change direction, change level or overcome obstructions Suspended – right to left BBB240XC BBB242XC CCB240XC CCB242XC L1 + L2 + N 0·2 0·4 0·5 0·7 0·2 0·4 0·5 0·7 16 A unfused tap-off unit Rewirable tap-off units colour coded white, can plug into any tap-off outlet 1·35 1·58 1·49 1·72 Flexible lengths for double sided system 1 1 1 1 L+N Weight (kg)(1) Pre-wired tap-off units to pick-up L1, L2+N, supplied with BS 1362 fuse, colour coded white Feed units for double sided system BBB24LFC BBB24RFC CCB24LFC CCB24RFC 0·8 2 3 5 0·8 2 3 5 Fixed polarity 13 A fused tap-off units Double sided feed units come with 2 x 25 mm Ø cable entry holes for each side of the bar, plus a further 2 x 16 mm Ø. holes for the comms side of the bar. Single screw cable terminals are provided for power and data 1 1 1 1 Tap-off units with and without comms Power only tap-offs can plug into any tap-off outlet Tap-offs with comms can only be plugged into the comms side of the bar 16 A unfused tap-off units Pre-wired tap-off units to pick up L1, L2+N, colour coded white 3P + E trunking lengths 25 A BBB3245C BBB2245C BBB3241C BBB2241C 40 A CCB3245C CCB2245C CCB3241C CCB2241C Cat. Nos. Electrak 31 3P + E – double sided system 3P + E buscom trunking system with integral communications bus circuit available in IP 4X and IP 54 versions Socket outlets are colour coded white and are located on both sides of the bar The comms circuit is only available on one side of the bar as shown in the diagram below 1 1 1 1 Pack Length (m) Rating (A) Weight (kg)(1) 0·5 2 0·5 2 25 25 40 40 3·45 4·03 3·53 4·35 1 1 DDF4F DDH4F Fixed polarity Weight (kg)(1) L+N L1 L2 N1 0·14 0·14 (1) Weights shown are for IP 4X rated buscom. For all other weights, contact us on +44 (0) 845 600 6266 Key : How to select the correct components All examples on this page show IP 4X buscom trunking IP rating and tap-off type is dictated by the red letters 4 = IP 4X. For IP 54 version, replace 4 with 5 C = Tap-off with communications circuit. For power only, remove the C 31 LTK_Bro_030_031 v3.indd 31 22/08/2012 16:20 Electrak® 32 4P + E (dual circuit) buscom trunking power and communication distribution CCC3145C CCC2145C CCC14RFC CCC142XC CCC14LFC Selection chart (p. 24-27) Dimensions and technical information (p. 38-43) Integral communication bus suitable for KNX, Lonworks, DALI protocols, etc. 25 A and 40 A systems Outlets on one or two sides. IP 4X or IP 54 ingress protection Fast installation (trunking push fits together in seconds). High quality materials. Suspended or surface mounted Pack Cat. Nos. Electrak 32 4P + E (dual circuit) – single sided system Pack Cat. Nos. Flexible lengths can be used to change direction, change level or overcome obstructions Dual circuit buscom trunking system with integral communications bus circuit available in IP 4X and IP 54 versions Socket outlets are colour coded white and are located on just one side of the bar 4 P + E trunking lengths Trunking lengths push fit into each other, and feed units or flexible lengths. Trunking lengths can be surface mounted or suspended using the various bracket options 1 1 1 1 1 1 1 1 25 A BBC3145C BBC2145C BBC3141C BBC2141C 40 A CCC3145C CCC2145C CCC3141C CCC2141C Length (m) Tap-off outlets Weight (kg)(1) 3 2 3 2 6 4 3 2 4·77 3·47 4·73 3·44 3 2 3 2 6 4 3 2 4·97 3·61 4·93 3·58 C L2 N2 L1 N1 PE Flexible lengths for single sided system Suspended – right to left 1 1 1 1 BBC140XC BBC142XC CCC140XC CCC142XC Length (m) Rating (A) Weight (kg)(1) 0·5 2 0·5 2 25 25 40 40 3·17 3·59 3·22 3·79 Surface mounted – right to left 1 1 1 1 BBC340XC BBC342XC CCC340XC CCC342XC Length (m) Rating (A) Weight (kg)(1) 0·5 2 0·5 2 25 25 40 40 3·09 3·51 3·14 3·71 Feed units for single sided system Feed units come with 2 x 25 mm Ø and 2 x 16 mm Ø cable entry holes and single screw cable terminals for power and data Left feed units are supplied with right end stop Right feed units are supplied with left end stop Centre feed units are supplied with right and left end stops Suspended Weight (kg)(1) 1 1 1 1 BBC14LFC BBC14RFC CCC14LFC CCC14RFC 25 A left 1·29 25 A right 1·52 40 A left 1·38 40 A right 1·61 Surface mounted Weight (kg)(1) 1 1 1 1 BBC34LFC BBC34RFC CCC34LFC CCC34RFC 25 A left 25 A right 40 A left 40 A right Centre feed 1·33 1·56 1·42 1·65 Weight (kg)(1) 1 1 BBC44FC CCC44FC 25 A 40 A 1·8 1·8 (1) Weights shown are for IP 4X rated buscom. For all other weights, contact us on +44 (0) 845 600 6266 Key : How to select the correct components All examples on this page show IP 4X buscom trunking IP rating is dictated by the red letters 4 = IP 4X. For IP 54 version, replace 4 with 5 32 LTK_Bro_032_033 v3.indd 32 23/08/2012 14:06 Electrak® 32 4P + E (dual circuit) buscom trunking power and communication distribution CCC3245C CCC2245C DDJ45 DDJ45C DDK4F Selection chart (p. 24-27) Dimensions and technical information (p. 38-43) Integral communication bus suitable for KNX, Lonworks, DALI protocols, etc. 25 A and 40 A systems Outlets on one or two sides. IP 4X or IP 54 ingress protection Fast installation (trunking push fits together in seconds). High quality materials. Suspended or surface mounted Pack Cat. Nos. 4 P + E trunking lengths Trunking lengths push fit into each other, and feed units or flexible lengths. Double sided trunking must be fixed using suspended fixing brackets 1 1 1 1 25 A BBC3245C BBC2245C BBC3241C BBC2241C 40 A CCC3245C CCC2245C CCC3241C CCC2241C Length (m) Tap-off outlets Weight (kg)(1) 3 2 3 2 11 7 6 4 5·46 3·92 5·37 3·88 3 2 3 2 11 7 6 4 5·86 4·70 5·77 4·15 BBC24LFC BBC24RFC CCC24LFC CCC24RFC PE N1 L1 N2 L2 C L2 N2 L1 N1 PE DDE408C DDE42C DDE43C DDE45C DDJ408C DDJ42C DDJ43C DDJ45C 0·8 2 3 5 0·8 2 3 5 Fixed polarity L1 + N1 L2 + N2 Weight (kg)(1) 0·2 0·4 0·5 0·6 0·2 0·4 0·5 0·6 13 A fused tap-off units Pre-wired tap-off units to pick up L1+N1 or L2+N2, supplied with BS 1362 fuse, colour coded white 1 1 1 1 1 1 1 1 DDE408FC DDE42FC DDE43FC DDE45FC DDJ408FC DDJ42FC DDJ43FC DDJ45FC 0·8 2 3 5 0·8 2 3 5 Fixed polarity L1 + N1 L2 + N2 Weight (kg)(1) 0·2 0·4 0·5 0·6 0·2 0·4 0·5 0·6 Feed units for double sided system Tap-off units without comms – rewirable 16 A unfused tap-off units Rewirable tap-off units to pick up required circuit, colour coded white, can plug into any tap-off outlet 25 A left 25 A right 40 A left 40 A right 1 1 DDF4 DDK4 Fixed polarity Weight (kg)(1) L1 + N1 L2 + N2 0·14 0·14 13 A fused tap-off units Rewirable tap-off units to pick up required circuit, supplied with BS 1362 fuse, colour coded white, can plug into any tap-off outlet 1·42 1·64 1·60 1·83 Flexible lengths can be used to change direction, change level or overcome obstructions Suspended – right to left BBC240XC BBC242XC CCC240XC CCC242XC Length (m) 1 1 1 1 1 1 1 1 Double sided feed units come with 2 x 25 mm Ø cable entry holes for each side of the bar, plus a further 2 x 16 mm Ø. holes for the comms side of the bar. Single screw cable terminals are provided for power and data Supplied with end stops Suspended Flexible lengths for double sided system 1 1 1 1 Tap-off units with and without comms Power only tap-offs can plug into any tap-off outlet Tap-offs with comms can only be plugged into the comms side of the bar 16 A unfused tap-off units Pre-wired tap-off units to pick up L1+N1 or L2+N2, colour coded white Length (m) Weight (kg)(1) 1 1 1 1 Cat. Nos. Electrak 32 4P + E (dual circuit) – double sided system Dual circuit buscom trunking system with integral communications bus circuit available in IP 4X and IP 54 versions Socket outlets are colour coded white and are located on both sides of the bar The comms circuit is only available on one side of the bar as shown in the diagram below 1 1 1 1 Pack Length (m) Rating (A) Weight (kg)(1) 0·5 2 0·5 2 25 25 40 40 3·42 4·52 3·91 5·32 1 1 DDF4F DDK4F Fixed polarity Weight (kg)(1) L1 + N1 L2 + N2 0·14 0·14 (1) Weights shown are for IP 4X rated buscom. For all other weights, contact us on +44 (0) 845 600 6266 Key : How to select the correct components All examples on this page show IP 4X buscom trunking IP rating and tap-off type is dictated by the red letters 4 = IP 4X. For IP 54 version, replace 4 with 5 C = Tap-off with communications circuit. For power only, remove the C 33 LTK_Bro_032_033 v3.indd 33 22/08/2012 16:21 Electrak® 33 4P + E (3 phase) buscom trunking power and communication distribution CCD3145C CCD2145C CCD14RFC CCD142XC CCD14LFC Selection chart (p. 24-27) Dimensions and technical information (p. 38-43) Integral communication bus suitable for KNX, Lonworks, DALI protocols, etc. 25 A and 40 A systems Outlets on one or two sides. IP 4X or IP 54 ingress protection Fast installation (trunking push fits together in seconds). High quality materials. Suspended or surface mounted Pack Cat. Nos. Electrak 33 4P + E (3 phase) – single sided system Pack Cat. Nos. 3 phase buscom trunking system with integral communications bus circuit available in IP 4X and IP 54 versions Socket outlets are colour coded grey and are located on just one side of the bar 4 P + E trunking lengths Trunking lengths push fit into each other, and feed units or flexible lengths. Trunking lengths can be surface mounted or suspended using the various bracket options 1 1 1 1 1 1 1 1 25 A BBD3145C BBD2145C BBD3141C BBD2141C 40 A CCD3145C CCD2145C CCD3141C CCD2141C Length (m) Tap-off outlets Weight (kg)(1) 3 2 3 2 6 4 3 2 4·77 3·47 4·75 3·44 3 2 3 2 6 4 3 2 4·97 3·61 4·93 3·58 C L3 L2 L1 N1 PE Flexible lengths for single sided system Flexible lengths can be used to change direction, change level or overcome obstructions Suspended – right to left 1 1 1 1 BBD140XC BBD142XC CCD140XC CCD142XC Length (m) Rating (A) Weight (kg)(1) 0·5 2 0·5 2 25 25 40 40 3·17 3·59 3·22 3·79 Surface mounted – right to left 1 1 1 1 BBD340XC BBD342XC CCD340XC CCD342XC Length (m) Rating (A) Weight (kg)(1) 0·5 2 0·5 2 25 25 40 40 3·09 3·51 3·14 3·71 Feed units for single sided system Feed units come with 2 x 25 mm Ø and 2 x 16 mm Ø cable entry holes and single screw cable terminals for power and data Left feed units are supplied with right end stop Right feed units are supplied with left end stop Centre feed units are supplied with right and left end stops Suspended Weight (kg)(1) 1 1 1 1 BBD14LFC BBD14RFC CCD14LFC CCD14RFC 25 A left 1·29 25 A right 1·52 40 A left 1·38 40 A right 1·61 Surface mounted Weight (kg)(1) 1 1 1 1 BBD34LFC BBD34RFC CCD34LFC CCD34RFC 25 A left 25 A right 40 A left 40 A right Centre feed 1·33 1·56 1·42 1·65 Weight (kg)(1) 1 1 BBD44FC CCD44FC 25 A 40 A 1·80 1·80 (1) Weights shown are for IP 4X rated buscom. For all other weights, contact us on +44 (0) 845 600 6266 Key : How to select the correct components All examples on this page show IP 4X buscom trunking IP rating is dictated by the red letters 4 = IP 4X. For IP 54 version, replace 4 with 5 34 LTK_Bro_034_036 v2.indd 34 23/08/2012 14:07 Electrak® 33 4P + E (3 phase) buscom trunking power and communication distribution CCD3245C CCD2245C DDM408L1C DDM408L1 Selection chart (p. 24-27) Dimensions and technical information (p. 38-43) Integral communication bus suitable for KNX, Lonworks, DALI protocols, etc. 25 A and 40 A systems Outlets on one or two sides. IP 4X or IP 54 ingress protection Fast installation (trunking push fits together in seconds). High quality materials. Suspended or surface mounted Pack Cat. Nos. Electrak 33 4P + E (3 phase) – double sided system Pack Cat. Nos. 3 phase buscom trunking system with integral communications bus circuit available in IP 4X and IP 54 versions Socket outlets are colour coded grey and are located on both sides of the bar The comms circuit is only available on one side of the bar as shown in the diagram below Pre-wired tap-off units to pick up required circuit, colour coded grey Length (m) 4 P + E trunking lengths Trunking lengths push fit into each other, and feed units or flexible lengths. Double sided trunking must be fixed using suspended fixing brackets 1 1 1 1 1 1 1 1 25 A BBD3245C BBD2245C BBD3241C BBD2241C 40 A CCD3245C CCD2245C CCD3241C CCD2241C Length (m) Tap-off outlets Weight (kg)(1) 3 2 3 2 11 7 6 4 5·46 3·92 5·37 3·88 3 2 3 2 11 7 6 4 5·86 4·70 5·77 4·15 PE N L1 L2 L3 C L3 L2 L1 N PE 1 1 1 1 1 1 1 1 1 1 1 1 DDM408L1C DDM42L1C DDM43L1C DDM45L1C DDM408L2C DDM42L2C DDM43L2C DDM45L2C DDM408L3C DDM42L3C DDM43L3C DDM45L3C Double sided feed units come with 2 x 25 mm Ø cable entry holes for each side of the bar, plus a further 2 x 16 mm Ø. holes for the comms side of the bar. Single screw cable terminals are provided for power and data Suspended BBD24LFC BBD24RFC CCD24LFC CCD24RFC 25 A left 25 A right 40 A left 40 A right 1·42 1·64 1·60 1·83 Flexible lengths for double sided system Flexible lengths can be used to change direction, change level or overcome obstructions Fixed polarity L1 + N L2 + N L3 + N Weight (kg)(1) 0·2 0·4 0·5 0·6 0·2 0·4 0·5 0·6 0·2 0·4 0·5 0·6 Pre-wired tap-off units to pick up required circuit, supplied with BS 1362 fuse, colour coded grey, can plug into any Electrak 33 tap-off outlet Length (m) 1 1 1 1 1 1 1 1 Weight (kg)(1) 0·8 2 3 5 0·8 2 3 5 0·8 2 3 5 13 A fused tap-off units Feed units for double sided system 1 1 1 1 Tap-off units Power only tap-offs can plug into any tap-off outlet of the 3 phase bar Tap-offs with comms can only be plugged into the comms side of the 3 phase bar 16 A unfused tap-off units 1 1 1 1 DDM408L1FC DDM42L1FC DDM43L1FC DDM45L1FC DDM408L2FC DDM42L2FC DDM43L2FC DDM45L2FC DDM408L3FC DDM42L3FC DDM43L3FC DDM45L3FC 0·8 2 3 5 0·8 2 3 5 0·8 2 3 5 Fixed polarity L1 + N L2 + N L3 + N Weight (kg)(1) 0·2 0·4 0·5 0·6 0·2 0·4 0·5 0·6 0·2 0·4 0·5 0·6 (1) Weights shown are for IP 4X rated buscom. For all other weights, contact us on +44 (0) 845 600 6266 Suspended – right to left 1 1 1 1 BBD240XC BBD242XC CCD240XC CCD242XC Length (m) Rating (A) Weight (kg)(1) 0·5 2 0·5 2 25 25 40 40 3·42 4·52 3·91 5·32 Key : How to select the correct components All examples on this page show IP 4X buscom trunking IP rating and tap-off type is dictated by the red letters 4 = IP 4X. For IP 54 version, replace 4 with 5 C = Tap-off with communications circuit. For power only, remove the C 35 LTK_Bro_034_036 v2.indd 35 22/08/2012 16:22 Electrak® 33 4P + E (3 phase) buscom trunking power and communication distribution DDN4L1F DDR43 Selection chart (p. 24-27) Dimensions and technical information (p. 38-43) Integral communication bus suitable for KNX, Lonworks, DALI protocols, etc. 25 A and 40 A systems Outlets on one or two sides. IP 4X or IP 54 ingress protection Fast installation (trunking push fits together in seconds). High quality materials. Suspended or surface mounted Pack Cat. Nos. Tap-off units without comms – rewirable Pack Cat. Nos. 16 A unfused tap-off units Rewirable tap-off units to pick up required circuit, colour coded grey, can plug into any Electrak 33 tap-off outlet 1 1 1 DDN4L1 DDN4L2 DDN4L3 Fixed polarity Weight (kg)(1) L1 + N L2 + N L3 + N 0·14 0·14 0·14 13 A fused tap-off units Rewirable tap-off units to pick up required circuit, supplied with BS 1362 fuse, colour coded grey, can plug into any Electrak 33 tap-off outlet 1 1 1 DDN4L1F DDN4L2F DDN4L3F Fixed polarity Weight (kg)(1) L1 + N L2 + N L3 + N 0·14 0·14 0·14 Tap-off units without comms – 4P + E pre-wired (LSOH 5 x 1·5 mm2 cable) 16 A unfused tap-off units Pre-wired tap-off units to pick up required circuit, colour coded grey, can plug into any Electrak 33 tap-off outlet 1 1 1 1 DDR408 DDR42 DDR43 DDR45 Length (m) Fixed polarity 0·8 2 3 5 L+L+L+N L+L+L+N L+L+L+N L+L+L+N Weight (kg)(1) 0·20 0·36 0·50 0·63 Phase selectable tap-off units without comms 2P + E terminals – rewirable 16 A unfused tap-off unit Rewirable tap-off units, phase selectable, colour coded grey, can plug into any Electrak 33 tap-off outlet 1 DDP4S Fixed polarity Weight (kg)(1) L+N 0·14 13 A fused tap-off unit Rewirable tap-off units, phase selectable, supplied with BS 1362 fuse, colour coded grey, can plug into any Electrak 33 tap-off outlet 1 DDP4SF Fixed polarity Weight (kg)(1) L+N 0·14 (1) Weights shown are for IP 4X rated buscom. For all other weights, contact us on +44 (0) 845 600 6266 Key : How to select the correct components All examples on this page show IP 4X buscom trunking IP rating is dictated by the red letters 4 = IP 4X. For IP 54 version, replace 4 with 5 36 LTK_Bro_034_036 v2.indd 36 23/08/2012 14:08 Electrak® buscom trunking fixings and ancillary items EEC348 EEA304 EEC356 EEB340 EEB344 EEA312 EEA308 EEA328 EEA332 EEA324 EEC352 EEC360 EEC364 Dimensions and technical information (p. 41) Brackets are manufactured from robust galvanised steel, ensuring that the entire installation can be expected to stand up to all normal site conditions Pack Cat. Nos. Fixings 1 EEA304 Ancillary items Pack Cat. Nos. Trunking 57 mm edge surface mounting fixing bracket 1 EEC356 2 m empty length for adjusting the length at the end of a run (to be cut) 1 EEA308 Trunking suspended fixing bracket 1 EEC360 IP 54 outlet cover (spare or replacement) 1 EEA312 Trunking suspended fixing bracket c/w cable duct stirrup. Used when running cable duct on top of buscom trunking 1 EEC364 Joint sleeve is used if load is hung off trunking joint or near when joint is centre of a fixing span 1 EEC366 Left hand end stop spare 1 EEA324 Luminaire suspension fixing bracket 1 EEC368 Right hand end stop spare 1 EEA328 Luminaire 45 mm edge suspension fixing bracket (clip on) 1 EEA332 Luminaire 57 mm edge suspension fixing bracket (clip on) 1 EEB340 Open hook luminaire suspended bracket 1 EEB344 Closed ring on luminaire 1 EEC348 Cable duct 3 m long x 50 mm(w) x 13 mm(h) 1 EEC357 Joint bracket cable duct 1 EEC352 Cable duct fixing bracket 37 LTK_Bro_037 v2.indd 37 22/08/2012 16:24 Electrak® buscom trunking technical information n Standards Electrical test data ASTA approved to BS EN 60439-2 and IEC 439-2 Manufactured within an approved ISO 9001 : 2008 facility Assessed Quality Assurance Certificate No. 10679 Electrak fully complies with the requirements of BS 7671 : 2008 (IEE Wiring Regulations) n Buscom trunking options •L •N PE • L2 • L1 •N PE • L2 • N2 • L1 • N1 PE • L3 • L2 • L1 •N PE 25 A 40 A UOM Derating factor for Electrak 32 single sided – 0·8 – Derating factor for Electrak 32 double sided 0·8 0·7 – Derating factor for Electrak 33 double sided – 0·8 – Rated operational voltage (Ue) 230/400 230/400 V Rated insulation voltage (Ui) 500 500 V Frequency (f) 50/60 50/60 Hz Rated impulse withstand voltage 4·0 4·0 KV 3·9 2·7 mΩ/m Busbar resistance (R20) 4·2 3·0 mΩ/m Resistance (R1) 4·8 3·4 mΩ/m Impedance (Z1) 2·5 1·6 mΩ/m Reactance (X1) Protective conductor 1·5 1·5 mΩ/m ± ± Communication bus Electrak buscom trunking can be used with Electrak’s cost effective lighting control system, Lightrak KNX, or any other systems using control protocols such as KNX, Lonworks, DALI, etc. Electrak’s overhead trunking couples high quality engineering with rigidity of design, and provides power for a variety of applications including lighting, heating and ventilation. The robust easy fix modular system permits loads to be suspended directly from the trunking using Electrak’s various fixing brackets Push fit connection keeps installation costs to a minimum Volt drops 25 A 40 A UOM Live and neutral : busbars (R1+R2) Feed unit Tap-off 0·8 m Tap-off 2·0 m Flexible length assembly 0·5 m Flexible length assembly 2 m 9·0 3·0 22·0 52·0 5·0 20·0 6·0 2·4 22·0 52·0 3·5 14·0 mV/A/m mV/A mV/A mV/A mV/A mV/A Earth fault loop 25 A 40 A UOM Impedance : busbar Earth housing Feed unit Tap-off 0·8m Tap-off 2·0m Flexible length assembly 0·5 m Flexible length assembly 2 m Rated conditional short-circuit current (Icc) Rated short time withstand current (Icw) at 1 sec Rated peak short-circuit current (Ipk) Ambient temperature 4·5 1·5 2·4 23·0 53·0 2·5 10·0 16·0 0·65 0·975 35·0 3·0 1·5 2·4 23·0 53·0 1·75 7·0 16·0 1·0 1·5 35·0 mΩ/m mΩ/m mΩ mΩ mΩ mV/A mV/A KA KA KA ˚C Mechanical data 25 A 40 A UOM Track lengths simply push fit together n Feed units 25 A rated - max. conductor size 6 mm2 40 A rated - max. conductor size 16 mm2 Double sided trunking feed units have power cable terminals on both sides. IP 4X galvanised steel IP 54 ABS Number of conductors Busbar conductor cross sectional area Cable terminal capacity Cable terminal capacity bus Tap-off cable 16 A Tap-off cable 13 A fused Tap-off entry Feed unit entry holes power Feed unit entry holes bus IP rating (optional) 2-10 2-10 4·0 6·0 6·0 16·0 1·5 1·5 1·5 1·5 1·5 1·5 16·0 16·0 25·0 25·0 16·0 16·0 4 X (54) 4 X (54) – mm2 mm2 mm2 mm2 mm2 mmØ mmØ mmØ – Direct protection by enclosure. Indirect protection by protective circuit 2 pole + earth + comms Comms bus Max. conductor size 1·5 mm2 Red + Black - 38 LTK_Bro_038_043 v3.indd 38 22/08/2012 16:27 Electrak® buscom trunking technical data Communication control circuit Type Construction Insulation - conductor Sheath Bus cable (LSOH) Sheathed 0·5 mm2 copper twisted pair Flame retardant low emission HCL LSOH material Rated insulation voltage (Ui) (between power circuit and bus) 500 V Max. bus operating voltage 50 V Max. bus operating current 0·65 A Max. conductor resistance (@20˚C) 73·2 Ω/km Max. mutual capacitance 100 nf/km Material specifications Buscom trunking housing Galvanised steel Busbars High conductivity copper Busbar insulator Flame retardant LSOH to BS 7211 Trunking connector / tap-off entry box / cable connector Flame retardant polycarbonate Tap-off housing Flame retardant polycarbonate Trunking connector blades / tap-off blades Copper Feed unit IP 4X Galvanised steel Feed unit IP 54 ABS Flexible length conduit Flame retardant LSOH nylon Feed unit terminals / earth block Brass Brackets Galvanised steel 13 A tap-off, fuse To BS 1362, ASTA approved Durability Electrak power and communications distribution systems are well designed and extremely robust. They can be expected to stand up to all normal site conditions Electrak has been short circuit strength tested by ASTA Earth fault loop impedance BS 7671 : 2008 IEE Wiring Regulations require accurate determination of the total earth loop impedance, which must be sufficiently low to allow the protective device to operate within the specified time, which for socket outlets is 0·4 seconds The values relevant to Electrak for calculating the earth fault loop impedance are shown in the electrical test data table, see opposite Buscom trunking rating in ambient temperatures Average ambient air temperature Rating factor (K1) 25˚C 30˚C 35˚C 40˚C 45˚C 50˚C 1·1 1·05 1 0·95 0·90 0·85 For ambient temperatures other than 35˚C apply the multiplier factor K1 to the rated current Buscom trunking mechanical loading For point loads and evenly distributed loads the maximum weight that can be supported is given below Maximum loading for suspended buscom trunking Fixing distance (m) 1·5 2 2·5 3 3·5 4 Max. point load (deflection = 1/500 x span) (Kg) 20 17 13 12 9 7 Max. distributed load (deflection = 1/500 x span) (Kg) 33 28 22 20 15 12 Max. point load (deflection = 1/350 x span) (Kg) 33 24 18 16 10 9 Max. distributed load (deflection = 1/350 x span) (Kg) 55 40 30 26 16 15 Maximum loading for surface mounted buscom trunking Fixing distance in metres (m) 1·5 2 2·5 3 3·5 4 Max. point load (deflection = 1/500 x span) (Kg) 10 6 4·5 4 3·5 3 Max. distributed load (deflection = 1/500 x span) (Kg) 16 10 7·5 7 6 5 Max. point load (deflection = 1/350 x span) (Kg) 13 10 7 6 5 0 Max. distributed load (deflection = 1/350 x span) (Kg) 20 16 11 10 8 0 Notes 1. Where trunking joints occur in the middle of the suspension span, and weight is to be suspended from that point, it is recommened to use a strenghting bracket EEC364 over the joint to stop deflection 2. If the load requirements exceed the above figures, please contact us on +44 (0) 845 600 6266 For design information and technical specification, please contact us on +44 (0) 845 600 6266 Suspension rods and fixings should be of suitable size to carry the weight of both the track and suspended load 39 LTK_Bro_038_043 v3.indd 39 22/08/2012 16:27 Electrak® buscom trunking dimensions n Fixing dimensions Buscom trunking 3 m 0·5 m outlet spacings 220 195·5 3 000 500 195·5 500 500 500 1 000 500 1 000 304·5 804·5 0·5 m outlet spacings Buscom trunking 2 m Buscom trunking End view 0·5 m outlet spacings 2 000 45 195·5 220 500 500 500 304·5 32 57 195·5 1 000 804·5 Suspended feed unit 0·5 m outlet spacings Feed unit – left Single sided system Feed unit – right Double sided system 2 x 16 Ø 2 x 16 Ø 148 57 209 308 220 517 2 x 25 Ø 209 104 End view both have 2 x 16 mm holes extra in comms feed 429 Surface feed unit – end view End stop – left End stop – right 4 x 25 Ø 52 148 52 10 220 320 2 x 25 Ø 2 x 16 Ø Centre feed – front view 57 2 x 25 Ø 220 218 2 x 16 Ø 300 308 828 ( All dimensions (mm) are nominal 40 LTK_Bro_038_043 v3.indd 40 22/08/2012 16:28 Cat. No. EEA304 Surface trunking fixing bracket with trunking clipped in 107 7·5 Cat. No. EEA324 Luminaire suspended fixing bracket 30 92 7·5 82 7Ø 99·7 7Ø 7Ø 94·5 60 15 8.5 Ø 22 57 12 8·5 Ø 38 Cat. No. EEA308 Suspended trunking fixing bracket 82 8·5 Ø Cat. No. EEA328 Luminaire 45 mm edge suspension fixing bracket 12 70 38 21 21 13 108 125 130 8·5 Ø 30 6Ø 6Ø 60 35 Cat. No. EEA332 Luminaire 57 mm edge suspension fixing bracket 21 82 38 53·5 Cat. No. EEA312 Suspended trunking fixing bracket cable duct stirrup 12 8·5 Ø 8·5 39 6Ø 6Ø 30 78 141 163 8·5 Ø Fused tap-off Cat. No. EEC352 Cable duct fixing bracket 12 Fuse holder Tap-off fuse removal 77 13 35 50 95 59 Pre-wired tap-offs – 33 mm deep 68 Cat. No. EEB344 Closed ring hook Cat. No. EEB340 Open hook M5 70 70 M5 All dimensions (mm) are nominal 96 Rewirable and phase selection tap-offs – 35 mm deep 68 136 41 LTK_Bro_038_043 v3.indd 41 22/08/2012 16:28 Electrak® buscom trunking installation n Design and installation Electrak’s buscom trunking system comprises continuous lengths of galvanised steel trunking available in 2 m and 3 m lengths with integral connectors and regular tap-off outlets on one or both sides Each trunking run commences with a feed unit for electrical and comms bus cable termination. The connection between the trunking, the feed unit and subsequent trunking lengths is push fit and requires no tools to terminate the connection or ensure good earthing. Each complete track run is finished with an end stop. Flexible lengths can be used to overcome obstructions or used as corners where required The trunking system is available with IP 4X or IP 54 ingress protection, fully factory tested and ASTA approved to BS EN 60439-2 : 2008 End stop Push fit connection 1 2 To install - push fit parts together To take apart - use a screwdriver to depress the locking catch 2 1 1 2 Left feed unit Buscom trunking lengths 2 1 2 1 Push in to release Considerations before installation Calculate the distance between fixing brackets - the maximum fixing distance should not exceed 4 m. If loads are to be hung, please consult loading charts on page 39. The maximum buscom trunking weight is 2 kg/m When fixing brackets to drop rods or surfaces, see mounting details below Suspended trunking fixing brackets Cable duct clips into bracket EEA312 When using cable duct along trunking EEA308 EEC352 Cable duct bracket EEB344 Surface mounted trunking fixing brackets 2 1 EEA304 57 mm Edge surface fixing bracket Considerations before installation Ensure surface is level. Screw fix through both fixing holes of surface fixing brackets to surface with No. 8 fixing screws Hook trunking into place and push fit to close 42 LTK_Bro_038_043 v3.indd 42 22/08/2012 16:28 Luminaire mounting fixing brackets : suspended trunking EEA324 Luminaire fixing brackets EEA328 45 mm Edge luminaire fixing brackets (maximum load 5 kg) Luminaire mounting fixing brackets : surface trunking EEA304 EEA304 EEA332 EEA332 EEB340 EEB344 EEA332 57 mm Edge luminaire fixing bracket (maximum load 5 kg) See maximum loading charts p. 39 All dimensions (mm) are nominal 43 LTK_Bro_038_043 v3.indd 43 22/08/2012 16:29 Contact details Quotations and Technical Support: The Power Distribution Division of Legrand Electric Ltd. Great King Street North, Birmingham, B19 2LF Tel: +44 (0) 845 600 6266 Fax: +44 (0) 845 600 6760 E-mail: powersales.uk@legrand.co.uk Customer Services: The Power Distribution Division of Legrand Electric Ltd. No. 1 Industrial Estate Medomsley Road, Consett, County Durham, DH8 6SR Tel: +44 (0) 845 600 6266 Fax: +44 (0) 845 600 6366 E-mail: powersales.uk@legrand.co.uk Accounts: Legrand Electric Ltd. Great King Street North, Birmingham, B19 2LF Tel: +44 (0) 870 608 9000 Fax: +44 (0) 870 608 9004 Head office (UK and Ireland): Legrand Electric Limited Great King Street North, Birmingham, B19 2LF Tel: 0870 608 9000 Fax: 0870 608 9004 Website: www.legrand.co.uk This document is printed on sustainably sourced paper. Please recycle. LTK_Bro_Covers v1.indd 2 Lightrak lighting control guide 09/2012. 3.5K Distributor: The Legrand logo is a registered trademark of the Legrand group of companies. 29/08/2012 12:21