yaggy colby - Olmsted County
Transcription
yaggy colby - Olmsted County
SITE SUMMARY BLVD. TREES TYP. (6 EA.) - OWNER TO INSTALL THE APPROPRIATE BLVD. TREE AND PROVIDE WARRANTY TO THE CITY OF ROCHESTER PARKS DEPARTMENT OR - BLVD. TREES TO BE INSTALLED BY CITY OF ROCHESTER PARKS DEPARTMENT AND THE OWNER TO PAY THE GOING RATE PER TREE TO THE PARKS DEPARTMENT ZONING CLASSIFICATION: PROPOSED USAGE: B-4 TRADE SHOPS (TYPE 1) TOTAL SITE AREA = TOTAL SITE ACREAGE = 13TH AVENUE NW 9,480.00 S.F. 0.22 ACRES FLOOR AREA CALCULATIONS B-4 MAXIMUM = 2,332 + 2,478EX = 4,810 TOTAL G.F.A. = 0.50 F.A.R. 0.50 F.A.R. PARKING CALCULATIONS REQUIRED (1/EMP + 1/200SF SALES AREA) 7 PROPOSED STALLS W/O HAN DICAP STALLS = 7 PROPOSED HANDICAPPED STALLS = 1 GREENSPACE CALCULATIONS REQUIRED (9,480 SQ. FT. x 10%) = PROPOSED = 948 S.F. 969 S.F. EXTERIOR LIGHTING REGULATION STANDARD: SIGN REGULATION STANDARD: EXTERIOR STORAGE REGULATION STANDARD: BUFFERYARD INDICATOR: BUFFERYARD CLASS (10' WIDTH): D C YAGGY COLBY ASSOCIATES ENGINEERS LANDSCAPE ARCHITECTS SURVEYORS • PLANNERS 717 THIRD AVENUE SOUTHEAST ROCHESTER, MINNESOTA 55904 507-288-6464 FAX 507-288-5058 EMAIL INFO@YAGGY.COM T,S,50% VIII D CANOPY PLANTINGS (2.5*607100') UNDERSTORY PLANTINGS (5.0*607100") SHRUBS (8.0*607100') 2: ti LU oi SETBACK REQUIREMENTS: REQUIRED FRONT YARD: MIN. REQUIRED SIDE YARDS: X MIN. SUM OF SIDE YARD: MIN. REAR YARD: REQUIRED SIDE STREET SIDE YARD: 15 FEET 0 FEET 0 FEET 0 FEET 7.5 FEET* * TYPE 1 DESIGN MODIFICATION APPLIED FOR. OWNER JOSEPH AND CINDY BOWMAN 1219 7TH STREET NW ROCHESTER, MINNESOTA 55901 PHONE NO. (507) 282-7779 u O _i < Q Z < I- o co LU Z z < Q_ UJ LT) H CD SITE ADDRESS 1219 7TH STREET NW ROCHESTER, MN 55901 I U < o DESCRIPTION Lot 10, Block 4 Repldt 4 & 10 Gooding's Addition, according to the plat therefore on file at the County Recorder's office, Olmsted County, Minnesota. LEGEND o CO PROPOSED BUILDING GENERAL NOTES UTILITY CLASSIFICATION PER MINNESOTA STATUTES 2002, SECTION 216D.04, SUBDIVISION 1A. THE EXISTING UNDERGROUND UTILITIES FOR THIS PROJECT SHALL BE CONSIDERED A "D" CLASSIFICATION. UTILITY CONNECTIONS NOTE IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PERFORM OR COORDINATE ALL NECESSARY UTILITY CONNECTIONS FROM EXISTING UTILITY LOCATIONS TO THE PROPOSED BUILDING AND PROPOSED ON SITE AMENITIES. THESE CONNECTIONS INCLUDE BUT ARE NOT LIMITED TO WATER. SANITARY SEWER, CABLE T.V.. TELEPHONE. GAS. ELECTRIC. ON-SITE ELECTRIC. SITE LIGHTING. SIGNAGE. ETC. 1.) ALL WORK SHALL CONFORM TO AND BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES. 2.) THE SPECIFICATIONS AND DETAILS AS PREPARED BY THE CITY ROCHESTER SHALL BE CONSIDERED A PART OF THESE DOCUMENTS AS IF BOUND HEREIN. 3.) THE CONTFiACTOR SHALL NOTIFY ALL APPROPRIATE ENGINEERING DEPARTMENTS AND UTILITY COMPANIES 72 HOURS PRIOR TO CONSTRUCTION. ALL NECESSARY PRECAUTIONS SHALL BE TAKEN TO AVOID DAMAGE TO ANY EXISTING UTILITY. 4.) THE LOCATION OF EXISTING UNDERGROUND UTILITIES AND ROCK ELEVATIONS ARE SHOWN IN AN APPROXIMATE WAY ONLY AND HAVE NOT BEEN INDEPENDENTLY VERIFIED ffY THE OWNER OR ITS REPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES AND ROCK ELEVATIONS BEFORE COMMENCING WORK. AND AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT BE OCCASIONED BY THE CONTRACTOR'S FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES AND ROCK ELEVATIONS. 5.) THE CONTRACTOR SHALL VISIT THE SITE AND INSPECT THE PROJECT AREA AND THOROUGHLY FAMILIARIZE HIMSELF WITH THE ACTUAL JOB CONDITIONS PRIOR TO BIDDING AND THE START OF ANY WORK. FAILURE TO VISIT THE SITE SHALL NOT REUEVE THE CONTRACTOR PROPOSED LANDSCAPING O or RECEIVED ^ o CANOPY PLANTINGS (2 EA.) I? to UNDERSTORY PLANTINGS (3 EA.) 00 REVISION HISTORY BOULEVARD TREES (6 EA.) - SEE NOTE ABOVE THE CONTRACTOR SHALL VERIFY AT THE SITE, ALL DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS, AND SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES. OMISSIONS, AND/OR CONFLICTS PRIOR TO PROCEEDING WITH THE WORK. 7.) THE CONTRACTOR SHALL NOT SCALE DRAWINGS. DIMENSIONS SHALL GOVERN. LARGE SCALE DRAWINGS SHALL GOVERN OVER SMALL SCALE DRAWINGS. NOTES AND DETAILS ON THE DRAWINGS SHALL APPLY TO ALL SIMILAR CONDITIONS WHETHER THEY ARE REPEATED OR NOT. J.) THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL "AS-BUILT" LOCATIONS OF PUBLIC AND PRIVATE INFRASTRUCTURE. AND MUST NOTIFY THE PROJECT ENGINEER PRIOR TO INSTALLATION. 6.) SHRUBS (5 EA.) SHEET NUMBER EXISTING TREE 2"TREE SCALE IN FEET < _J C1.0 ONE CO