Stoneridge
Transcription
Stoneridge
Stoneridge Tachograph Programmer User Manual 1 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs 1. INTRODUCTION.............................................................................. 4 1.1 What does the Tachograph Programmer do?........................................................ 4 1.2 With which Tachograph Types can the Programmer be used ?............................. 4 1.3 How do I use This Manual?.................................................................................... 4 1.4 What version of Tachograph Programmer Software does this Manual Support ? .. 5 2. PREPARATION FOR USE............................................................... 6 2.1 Power Supply......................................................................................................... 6 2.1.1 Battery Charging ............................................................................................ 6 2.2 Connectors ............................................................................................................ 6 2.3 Connection Harnesses........................................................................................... 8 2.4 Functions of the Keys ............................................................................................ 8 2.5 Switching On.......................................................................................................... 8 2.6 Diagnostics Menu .................................................................................................. 9 2.6.1 Diagnostics Menu - Function Descriptions .................................................... 9 2.6.2 Diagnostics Menu - Operation of Functions.................................................. 10 2.7 Selection of tachograph type ............................................................................... 12 2.8 Selection of Pulser type (Stoneridge VR8300/1400) ............................................ 12 2.9 Selection of SENDER TYPE (Stoneridge VR2400).............................................. 13 3. PROGRAMMER FUNCTIONS ....................................................... 14 4. FUNCTION DESCRIPTIONS ......................................................... 17 4.1 Enter PIN Code.................................................................................................... 17 4.2 W-factor (Vehicle Characteristic Coefficient) Determination ................................ 17 4.2.1 Rolling Road (Hartridge or similar) ............................................................... 19 4.2.2 Fixed Distance Method No. 1 ....................................................................... 20 4.2.3 Fixed Distance Method No. 2 ....................................................................... 23 4.3 Bench Test (Connections) ................................................................................... 25 4.4 Distance Test....................................................................................................... 27 4.5 Speed Simulator .................................................................................................. 28 4.6 Revs per minute pulse test .................................................................................. 29 4.7 Clock Test............................................................................................................ 30 4.7.1 Clock Test – Motometer, Stoneridge VR2400/SE5000, Kienzle 1324/DTCO and Actia Smartach ..................................................................................................... 30 4.7.2 Clock Test – Stoneridge VR8400/8300 Series and Kienzle 1314/1318/1319 31 4.8 Pair/Test Tacho. .................................................................................................. 32 4.9 Tacho Control ...................................................................................................... 32 2 Ltd Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Manufacturers of VEEDER-ROOT Tachographs 4.10 Identify Tacho – Stoneridge VR2400/SE5000 Series, Kienzle 1324/DTCO and Actia Smartach................................................................................................................ 33 4.11 Read/Erase DTCs – Stoneridge VR2400/SE5000 Series, Kienzle 1324/DTCO and Actia Smartach................................................................................................................ 34 4.12 K-Factor Test....................................................................................................... 35 4.13 DIL Calculate ....................................................................................................... 37 4.14 Time / Date. ......................................................................................................... 37 5. PROGRAMMING A TACHOGRAPH .............................................. 38 5.1 Programming Stoneridge VR8400 Series tachographs........................................ 38 5.2 Programming Stoneridge VR2400 Series tachographs........................................ 40 5.3 Programming Kienzle 1324 Series tachographs .................................................. 44 5.4 Programming Kienzle 1319 Series tachographs .................................................. 46 5.5 Programming MotoMeter EGK-100 tachographs ................................................ 49 5.6 Programming SE5000 Series tachographs .......................................................... 51 5.7 Programming DTCO Series tachographs ............................................................ 57 5.8 Programming Smartach Series tachographs ....................................................... 60 5.8 Reading of speed pulses from the front of Kienzle 1314, 1318 and 1319 ............ 63 ANNEX A - TEST HARNESSES FOR USE WITH THE TACHOGRAPH PROGRAMMER .....64 ANNEX B - DETAILS OF BENCH TEST ROUTINES................................................................69 (a) UK Bench Test .....................................................................................................................69 (b) French Bench Test ...............................................................................................................71 (c) German Bench Test .............................................................................................................74 (d) Swedish Bench Test.............................................................................................................80 (e) Dutch Bench Test.................................................................................................................82 (f) Belgian Bench Test...................................................................................................................86 (g) Programming of a Custom Bench Test ................................................................................90 (h) Digtial Tachograph Bench Test ............................................................................................91 ANNEX C - VR2400 SERIES TACHOGRAPH – DIAGNOSTIC TROUBLE CODES (DTC) .....93 ANNEX D - CHARACTER MAP. ................................................................................................94 ANNEX E - LANGUAGE CODES FOR PREFERRED LANGUAGE..........................................94 3 Ltd Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Manufacturers of VEEDER-ROOT Tachographs 1. INTRODUCTION 1.1 What does the Tachograph Programmer do? • Determines the characteristic coefficient (‘W-factor’) of a vehicle using a rolling road or either of two different fixed-distance methods; • Carries out bench tests of Tachographs semi-automatically; • Checks the K-factor setting of Tachographs; • Calculates the DIL switch settings for any valid K-factor; • Can be used as a Tachograph speed simulator; • Determines the appropriate pulses per engine revolution (PPR) setting for a vehicle; • Allows Tachograph internal parameters to be Read and Checked and Reprogrammed if required (Note: Stoneridge VR8400/2400/SE5000 Kienzle 1319/1324/DTCO, Motometer EGK100 and Actia Smartach tachographs only); • Allows the initiation self-test modes; • Allows the resetting of the memory to default values; • Can carry-out a Tachograph Clock Test; • Can analyse the Diagnostic Trouble Codes (DTC) stored internally in the Stoneridge VR2400/SE5000, Kienzle 1324/DTCO and Actia Smartach Tachographs (see Annex C for a full list of DTCs); • Includes internal diagnostics routines to confirm that the Programmer is functioning correctly. 1.2 With which Tachograph Types can the Programmer be used ? The Tachograph Programmer can be used with all available types of electronic tachographs, i.e. Stoneridge VR1400/8300/8400/2400/SE5000, Kienzle 1314/1318/1319/1324/DTCO, MotoMeter EGK-100 and Actia Smartach. 1.3 How do I use This Manual? This manual describes, in detail, all the functions performed by the Tachograph Programmer. The Tachograph Programmer can be used with all electronic tachographs, many of which require slightly different procedures. To make it easier to find the information you require, the manual is structured as follows: Chapter 2: PREPARATION FOR USE Basic instructions for starting to use the Programmer, including checking and charging the battery, and how to select the Tachograph type to be programmed. 4 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Chapter 3: MAIN MENU PROGRAMMER FUNCTIONS Briefly describes the functions performed by the Programmer. A quick-reference Table (Table 1) lists the functions available for each Tachograph type and the harnesses that are required for each Programmer function. Chapter 4: FUNCTION DESCRIPTIONS AND DETAILS OF TEST PROCEDURES This gives a more detailed description of the different functions available in the Tachograph Programmer and provides Step-by-step procedures for carrying out the various Tachograph tests and functions. Chapter 5: PROGRAMMING A TACHOGRAPH Once the various Tachograph parameters have been determined (using the Tests described previously), the values determined must be sent to the Tachograph so that it can be updated with the correct parameter values. 1.4 What version of Tachograph Programmer Software does this Manual Support ? This manual covers the Tachograph Programmer functionality for Software version Rev2.03. The determination of the current Software Version in a Tachograph Programmer is described in section 2.6 (Diagnostics Menu – ROM Test). A Tachograph Programmer with an older version of Software can be upgraded to the current version (i.e., version Rev2.03). For further information on programmer software upgrades, please contact Stoneridge via E-mail at “sales@elc.stoneridge.com”. A Programmer upgrade is done using a Standard PC running a dedicated installation Program which is available on a Programmer Upgrade CD. The PC (Serial Communications Port) is connected to the Programmer (Socket D on Figure 1) via a Field Download Cable (Part Number: 7780-953). 5 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs 2. PREPARATION FOR USE 2.1 Power Supply The Tachograph Programmer is powered from an internal rechargeable nickel metal hydride battery pack. The voltage of the Battery Pack may be checked at any time by selecting Battery Detect from the Diagnostics Menu - see section 2.6 (Diagnostics Menu – Battery Detect) for details. The 9.6V Battery Pack has a capacity of 600mA/hr. The idle current of the programmer is approximately 30mA, rising to a maximum of 78mA when in normal use. Standard use of the communications features results in a current consumption of around 45mA. The OFF state current consumption is around 35 A, which maintains the function of the Programmers internal temperature compensated real-time clock. Based on these figures, a fully charged battery pack should give a continuous power on time of approximately 13 hours. Assuming a badly degraded battery, the programmer should have an expected worst case power-ON time of around 7 hours before recharge is required. 2.1.1 Battery Charging The battery is recharged using the AC charger supplied in the Programmer kit (illustrated as Harness I in ANNEX A - ). When fully discharged, the battery will take approximately 14 hours to recharge. The unit will then operate for at least 8 hours before requiring recharging. To conserve battery charge, the unit will switch off automatically after 10 minutes of non-use (except when in a bench test mode) or if the Voltage drops below 8V - the Critical voltage - below which tests can become inaccurate. The Programmer should NOT be continuously connected to the charger after an overnight charge. This can greatly reduce the Batteries performance, and in extreme cases destroy the Battery. 2.2 Connectors The Tachograph Programmer has three connectors on the end of the unit above the display and two others on the side and on the bottom, as shown on Figure 1 (see below). A. 6-pin DIN socket for connection of battery charging unit, bench test leads, pulser leads for rolling road or fixed distance calibration and Stoneridge VR8400 programming leads. B. 4-pin DIN socket for connection of flexi-switch. C. 8-pin DIN socket for connection of Stoneridge VR2400/SE5000, Kienzle 1319/ 1324/DTCO, MotoMeter and Actia Smartach tachographs. D. RJ11 Socket used for upgrading the Programmer Software version. E. Smartcard Connector. Smartcards are capable of storing digital information so that the data stored can be read by suitable electronic devices. The MKII Tachograph Programmer has a smartcard slot which may be utilised in the future for a variety of uses including security. 6 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs FIGURE 1: MKII TACHOGRAPH PROGRAMMER OUTLINE Socket B Socket C Socket A Socket D Socket E 7 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs 2.3 Connection Harnesses A range of different connection harnesses is supplied in the Programmer kit to allow many different connections to tachograph systems according to the functions required. These are illustrated and described in Annex A, and are referred to as appropriate throughout this manual. 2.4 Functions of the Keys MENU - Press to return to the MAIN MENU ENTER - Either selects a setting to be changed or terminates an entry. - Cycles through the options available for a particular setting. Press either of these keys as appropriate to move to the required function and then press ENTER to select. SEND - Sends parameter information to the attached tachograph. DELETE - Allows deletion of the entered value. 0 ... 9 - Numeric keys for entry of numeric values. They also have the secondary function as shortcut keys (see below) and the tertiary function of inputting letters. - The 1 and 4 keys have an additional function and are used to alter the speed in a speed test. - Used for turning the instrument on and off. Note that if the unit is left for 10 minutes without any keys being pressed then the unit will turn off automatically (except in bench test mode). ON/OFF to facilitate faster and easier use of the Programmer, the number keys also have shortcut key functions (the shortcut keys are only active if the Tachograph type selected supports the function). The shortcuts are as follows: Shortcut keys- 123456789- Rolling Road test. Fixed Distance #1 test. Fixed Distance #2 test. Clock test. R.P.M. Pulse test. K-Factor test. Read All Data. Modify Data. Send All Data. 2.5 Switching On To switch ON the Tachograph Programmer, press the ON/OFF button on the keyboard. The unit will first display a copyright message and the software version and then, after an audible beep, will display the MAIN MENU. From this menu the required functions may be selected. If the ENTER key is held down while switching ON, the Programmer will request a Pass code – type “8642” and press “ENTER” – the Programmer will then enter the Diagnostics Menu. Please note that the use of the Pass code is only to prevent unwanted entry to the Diagnostics Menu. The Diagnostics functions are described in Section 2.6. 8 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs 2.6 Diagnostics Menu Within the Tachograph Programmer there are a number of additional functions provided which carry out various self-test functions and which allow setting of various default values. To gain access to the internal utilities, first ensure that the Tachograph Programmer is turned off. Press and hold the ENTER key and then turn on the unit by pressing the ON key. As the unit turns on it will emit a beep as usual, but in this case will request a Pass code – type “8642” and press “ENTER” – the Programmer will then enter the DIAGNOSTICS MENU. 2.6.1 Diagnostics Menu - Function Descriptions Language Select - The MKII Tachograph Programmer may be operated in a number of different languages. The available languages are dependant on the Tachograph Programmer type. Set Time and Date - This is used to set the time (24 hour clock) and date (ddMMyyyy format) used by the Programmer. Fixed Distance Length - This allows the Length of the Fixed Distance Track (used in Programmer Fixed-Distance Tests) to be altered between 20 and 1000m (previously this was fixed at 20m permanently). Hardware Test - This function is used in conjunction with an external test jig for conformance testing. It is for use by SE personnel only. Keyboard Test - This enables the user to check that the keyboard is fully functional by pressing each key in turn. Display Test - This causes the unit to display a visual routine so that the user can check that the display is functioning correctly. ROM Test - This function can be used to check the Programmer’s internal read-only memory (ROM) and display the result. Battery Detect - This is used to check the Voltage of the Programmer’s internal battery pack. If within tolerance, message “Battery OK!” should be displayed. If not then the battery needs recharging. Frequency Test - Used during conformance testing to calibrate the accuracy of the clock within the Tachograph Programmer. This function is for use by SE personnel only. Set calib no. - This enables a user to enter a default identification string for a particular tachograph fitting station. Generally this is the identification issued by the approvals authority. Bench test type - This allows the selection of the appropriate bench test for any given country. Standard bench tests are pre-programmed for several countries; selecting the Custom bench test option allows a user to define a different test sequence. See Annex B for details of the Bench Tests available and instructions for programming a custom bench test. 9 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs 2.6.2 Diagnostics Menu - Operation of Functions With the Programmer OFF, press and hold the ENTER key and switch the device ON. Enter PIN :8642 To prevent unintentional use of the Diagnostic functions, a pass code will be requested. Type in 8642, and press ENTER. By pressing the ← or → keys the required function may then be displayed. Language Select - Press ENTER and the current language and the characters ← → will be displayed (on the right of display). DIAGNOSTICS MENU :Language Select Press the required key (← or →) until the required language is shown and then press ENTER again to make the selection permanent. The language selected will then be used for all the operating menus until a different language is selected. Press MENU once to DIAGNOSTICS MENU. return to SELECT LANGUAGE :English ←→ the Set time & date - Press ENTER and type in the time in the format shown on the screen. DIAGNOSTICS MENU :Set time & date Press ENTER after setting the time to set the date in the format shown on the screen. Time: HHmm :09:45 When the time and date have been set, press ENTER to confirm the settings. Date: ddMMyyyy :01/07/2003 Note : The time entered should be UTC time. Fixed Dist leng – Press ENTER to display the Fixed Distance Length. DIAGNOSTICS MENU :Fixed Dist leng Press ENTER to change the distance (Note: Range is 20 to 1000m). Enter the distance required and press the ENTER key to accept. Enter distance :20 m Press MENU to return to the Diagnostic Menu. Hardware Test – This test is to be applied by the manufacturer only. DIAGNOSTICS MENU :Hardware Test Keyboard Test - Press ENTER and then DIAGNOSTICS MENU 10 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs press the correct key when prompted. When the test is successfully completed the message: Keyboard OK! will appear briefly on the screen. :Keyboard Test Display Test - Press ENTER to start the test procedure. DIAGNOSTICS MENU :Display Test The default contrast is 25% but this may be changed using keys 1 or 4. Adjust contrast :25% Press ENTER and the test runs automatically. ROM Test - Press ENTER to start the test procedure. DIAGNOSTICS MENU :ROM Test The Checksum will appear after a brief interval. (c)2006 Rev 2.03 :Checksum = XXXX Press the MENU key once to return to the Diagnostics Menu. Note that the actual checksum value will depend on the version of software in the Programmer. Battery Detect - Press ENTER to start the test procedure. DIAGNOSTICS MENU :Battery Detect The battery voltage will appear after a brief interval. Battery OK! :11.239V Press the MENU key once to return to the Diagnostics Menu. Frequency Test – This test is to be applied by the manufacturer only. DIAGNOSTICS MENU :Frequency Test Set calib no. - Press ENTER to view the current calibration number. DIAGNOSTICS MENU :Set calib no. Press ENTER a second time to change the calibration number if necessary. Set calib no. SE 1234 Once the number has been changed, press ENTER a third time to confirm the new values. Press the MENU key to return to the DIAGNOSTICS MENU. 11 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Benchtest type - Press ENTER to display the current Benchtest type. DIAGNOSTICS MENU :Benchtest type Use the ← or → keys to select UK, French, German, Swedish, Dutch, Belgium or to Custom the bench test procedure. Benchtest type :UK ←→ Press ENTER to select the required type. 2.7 Selection of tachograph type Before using the Programmer, the model of tachograph being calibrated must be selected from the Main Menu. When the Programmer is switched on the first item displayed on the MAIN MENU is TACHO SELECT. From elsewhere in the MAIN MENU press the ← or → keys until TACHO SELECT is displayed. VR2400 MAIN MENU :TACHO SELECT Press ENTER and the TACHO TYPE menu will be displayed. Press ENTER again and then use the ← or → keys to select TACHO TYPE the appropriate tachograph type (Stoneridge :2400 Series VR2400/8400/8300/1400/SE5000 series, Kienzle 1324/1319/1318/ 1314/DTCO, Motometer EGK-100 and Actia Smartach). Press ENTER to make the selection and then MENU to return to the MAIN MENU. 2.8 Selection of Pulser type (Stoneridge VR8300/1400) For Stoneridge VR8300 or VR1400 series tachographs, the pulser type to be used must also be selected. This is to ensure that any calibration factor determined is correct. VR1400 MAIN MENU :PULSER SELECT With the Programmer at the MAIN MENU and displaying PULSER SELECT, press ENTER and PULSER TYPE will be displayed. Use the ← or → keys to select the appropriate pulser type. Press ENTER to make the selection and then MENU to return to the MAIN MENU. PULSER TYPE :8 Pulses/Rev ← → Note: The 2 pulse/rev option should only be selected when the tachograph is fitted with a Stoneridge Veeder-Root 2-pulse sender. The 8 pulse/rev option must be selected for all other pulsers regardless of the actual number of pulses per rev from the sender. 12 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs 2.9 Selection of SENDER TYPE (Stoneridge VR2400) For Stoneridge VR2400 series tachographs, the sender type may be selected. VR2400 MAIN MENU :PULSER SELECT SENDER TYPE : Encrypted ← → With the Programmer at the VR2400 MAIN MENU and displaying PULSER SELECT, connect a Cable U between the Programmers’ Socket ‘C’ and the 2400 Tachograph and then press ENTER. Use the ← or → keys to scroll through the options until the preferred sender type is displayed. Press ENTER and again to confirm the selection. The four choices available for sender Type are: Encrypted, 4-Wire, 3-Wire and Magnetic. Please note that for all other Tachograph types no sender type is selectable. 13 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs 3. PROGRAMMER FUNCTIONS This Chapter briefly describes all the MKII Programmer functions and lists the required harnesses in Table 1. A full description of each function is included in Chapter 4. • Tacho Select - this function allows the operator to specify the tachograph type that is to be calibrated or tested by the Programmer (see section 2.7 for more details). • Pulser Select (Stoneridge VR8300/1400 and Kienzle 1314) – this function allows the operator to specify the pulser type (or sender type for VR2400) that is being used with the current tachograph (see sections 2.8 and 2.9 for more details). • Rolling Road Test (all) - this function finds the “W” factor of the vehicle using the Hartridge (or similar) Rolling Road (see section 4.1.1 for more details). • Fixed Distance #1 Test (all) - this function finds the “W” factor of the vehicle using the Physical method 20m track (see section 4.1.2 for more details). • Fixed Distance #2 Test (all) - this function finds the “W” factor of the vehicle using the Physical method 20m track with Flexi-Switch (see section 4.1.3 for more details). • Bench Test (all) - this semi-automatic function assists the fitter to bench test the tachograph using a series of commands displayed on the screen (see section 4.2 for details of Bench Test connections and Annex B for full details of all Bench Test Routines). • Speed Simulator Test - this function injects speed pulses into the tachograph for checking of tachograph speed pointer, overspeed warning, or stylus positions on chart (see section 4.3 for more details). • RPM Pulse Test (Stoneridge VR2400/8400/8300, Kienzle1318, Motometer EGK100, 4-stylus tachographs only) - this function is used to find the “Pulse Per Engine Rev” from the “W” terminal on the alternator or a revs sender (see section 4.4 for more details). • Clock Test - this function checks the accuracy of the tachograph clock. The function is automatic for Motometer EGK100 tachograph, Stoneridge VR2400/SE5000, Kienzle 1324/DTCO and Actia Smartach but uses an optional external clock-tester for other tachographs (see section 4.5 for more details). • Tacho Control (Stoneridge VR8400/2400 and Kienzle 1324) - this function is used to put the tachograph into either the “Self Test” or the “Extended Test” mode, to Reset the tachograph memory to the “Default state” or to pair a tachograph with a sender (2400/1324 only) (see section 4.8 for more details). • Identify Tacho (Stoneridge VR2400/SE5000, Kienzle 1324/DTCO and Actia Smartach) – this function interrogates the tachograph via the K-line and determines the System supplier, Manufacture date, Serial number, Hardware version, Software number, Software version and System name (see section 4.9 for more details). • Read/Erase DTCs (Stoneridge VR2400/SE5000, Kienzle 1324/DTCO and Actia Smartach) enables the Diagnostic Trouble Codes in the tachograph to be displayed on the Programmer and then erased if required (see section 4.10 for more details). • Read all data/ Modify data/ Send all data (Stoneridge VR2400/SE5000, Kienzle 1319/1324/DTCO, EGK100 and Actia Smartach) - these functions interrogate the tachograph via the K-line to allow the fitter to change the various settings on the tacho and program all the data set-up in the Programmer in a single operation (see Chapter 5 for more details). 14 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs • Program Tacho (Stoneridge VR8400) - this function can be used to select various settings such as “Ignition Recording On” and “Overspeed Setting” (see section 5.1 for more details).. • K-factor Test (Stoneridge VR8400 and Kienzle 1319, 1318, 1314) - this function measures the “K” factor currently set on the tachographs (see section 4.11 for more details). • DIL calculate (Stoneridge VR8400/8300/1400, Kienzle1318) - this function eliminates the need to look up calibration tables (see section 4.12 for more details). • Time/Date (Stoneridge SE5000, Kienzle DTCO, Actia Smartach) – this function allows the time/date, and time offset in the tachograph to be read and modified. • Pair/Test (Stoneride SE5000, Kienzle DTCO) – this function can be used to pair the sender, and allow a number of tests to be carried out on the tachograph. Table 1: Available functions and required harnesses Tachograph VR240 0 VR840 0 VR830 0 VR140 0 K1324 K1319 K1318 K1314 MotoMeter EGK10 0 SE500 0 DTCO Smartach Rolling Road U or D G+J or D G+J or D K W or D G+O+J G+J or D G+J or L N Z or D Z or D Z or D Fixed Dist #1 U or D G+J or D G+J or D K W or D G+O+J G+J or D G+J or L N Z or D Z or D Z or D Fixed Dist #2 U or D G+J or D G+J or D K W or D G+O+J G+J or D G+J or L N Z or D Z or D Z or D Bench Test C G+S+J or C C K C or O G+O+J or C G+S+J or C G+T+J or L C+M or N Z Z Z Speed Simulator U or C G+S+J or C C K W or C G+O+J or C G+S+J or C G+T+J or L C+M or N Z Z Z RPM Pulse Test E E E - W - E - N - - - Clock Test U Clock Tester Clock Tester - W Clock Tester Clock Tester Clock Tester N Z Z Z Tacho Control U G+J - - W or C - - - N - - - Identify Tacho U - - - W - - - - Z Z Z Read/Erase DTCs U - - - W - - - - Z Z Z Function Table 1: Available functions and required harnesses (continued) Tachograp h VR240 0 VR840 0 VR830 0 VR140 0 K1324 K1319 Function K1318 K1314 MotoMeter EGK1 00 SE500 0 DTCO 15 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Smartach Send All Data U G+J - - W P - - N Z Z Z Modify Data U - - - W P - - N Z Z Z Read All Data U - - - W P - - N Z Z Z Program Tacho - G+J - - - - - - - - - - K-Factor Test - G+J - - - G+O+ J G+J G+J - - - - Pair / Test - - - - - - - - - Z Z - Time / Date - - - - - - - - - Z Z Z Enter PIN - - - - - - - - - Z - - Notes: (1) Fixed Distance #2 also requires the Flexi Switch. (2) DIL Calculate and Tacho Select and Pulser Select do not require any connections. 16 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs 4. FUNCTION DESCRIPTIONS This chapter describes the application of the Tests available in the MKII Tachograph Programmer, gives details of the connections required for each and provides a step-by-step instruction guide for each function for the inexperienced user. 4.1 Enter PIN Code. In order to read or inject pulses or to write data via the front programming connector of a digital tachograph, the tachograph must be put into calibration mode. Calibration mode consists of a valid workshop card being inserted into the tachograph, and a PIN code entered. In the case of the SE5000 the PIN code can be entered either through the tachographs keypad, or via the programmer. A PIN code function is available through the Main Menu, but the programmer may also prompt for a PIN code if a function is attempted while the tachograph is not in calibration mode. Entering a PIN through the programmer operates in a similar manner to SMS messaging. Continually pressing a key will cycle through a list of characters under that key. Pressing a new key or waiting for approx 5 seconds, will move to the next character. Pressing Enter will ask the tachograph to authenticate the PIN. If too many characters are entered, use the arrow and delete keys to correct. The list of characters under each key is detailed in Annex D In the case of the DTCO the PIN code can only be entered through the tachograph keypad. Insert the workshop card into the tachograph, and insert the front connector from the programmer into the Tachograph. From the MAIN MENU select ENTER PIN using the ← and → keys. Press ENTER. SE5000 MAIN MENU :ENTER PIN The programmer should request the code to be entered. Enter the correct Code for the workshop card and Press Return Enter PIN : 4.2 W-factor (Vehicle Characteristic Coefficient) Determination The MKII Tachograph Programmer can use three different methods of determining the W-factor for a vehicle, namely Rolling Road, Fixed Distance #1 and Fixed Distance #2. In each case the W-factor (revs/km for a 2-pulse sender or pulses/km for other senders) is determined and displayed. Where appropriate the correct setting of the tachograph DIL switches is indicated. The choice of the method to be used will depend on the other facilities available. However, the connections between Programmer and tachograph or sender are the same for all three of the calibration methods used: 17 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Table 2: W-factor Test connections Tachograph Harness Connection Stoneridge VR2400 Series U or D Connect to front of tachograph or directly to the vehicle sender. Stoneridge VR8400/ 8300 Series, G+ clip J Jack plug of harness G to socket inside front of Tachograph or D only DIN plug of harness G to Programmer socket A; Use Crocodile clip J to make required ground connection to a suitable point on the vehicle. Stoneridge VR1400 Series K DIN plug of harness K to Programmer socket A; connect appropriate black plug into socket on back of tachograph; connect other black plug directly to vehicle sender. Kienzle 1314 G+J or L only As 8400 or DIN plug of harness L to Programmer socket A; Connect appropriate white plug into socket on back of tachograph; Connect other white plug directly to vehicle sender. Kienzle 1318 C or G+J Jack plug of harness G to socket inside tachograph DIN plug of harness G to Programmer socket A; Use Crocodile clip J to make required ground connection to a suitable point on the vehicle. Or DIN plug of harness C to socket A on Programmer and other end to socket B of tachograph. 18 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Kienzle 1319 C or G+O+J Jack plug of harness G to socket on harness O and 8 way connector of O to socket inside tachograph. DIN plug of harness G to Programmer socket A; Use Crocodile clip J to make required ground connection to a suitable point on the vehicle. Or DIN plug of harness C to socket A on Programmer and other end to socket B of tachograph. Kienzle1324 W DIN plug to Programmer socket C. Other end to D-shaped socket on front of tachograph. MotoMeter EGK-100 N One DIN plug of harness N to Programmer socket A; Other DIN plug to MotoMeter programming socket. SE5000/DTCO/ Smartach Z DIN plug to Programmer socket C. Other end to D-shaped socket on front of tachograph. All tachographs (Fixed Distance #2 test) Flexi-switch Connect to Programmer socket B, and mount flexi-switch on vehicle chassis. Where a suitable connection is not available on the front of the tachograph to read pulses from the sender, it is necessary to make a connection direct to the sender, using Harnesses D (Stoneridge VR8300/8400/2400/SE5000 series, Kienzle 1319/1324/DTCO Series and Actia Smartach), K (Stoneridge VR1400 series) and L (Kienzle 1314). The tachograph is bypassed completely when using these harnesses, and a separate ground connection is not required. 4.2.1 Rolling Road (Hartridge or similar) This method uses the Tachograph Programmer in conjunction with a rolling road. The vehicle to be calibrated is positioned with its driving wheels on the rollers of the rolling road and is then driven at a constant speed of 50km/h. The Tachograph Programmer will then determine the Wfactor. 19 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Procedure Select ROLLING ROAD from the Main Menu, and follow the instructions as displayed below; From the MAIN MENU select ROLLING ROAD (shortcut key 1)using the ← and → keys. Press ENTER. VR2400 MAIN MENU :ROLLING ROAD Increase the speed of the vehicle as indicated by the rolling road equipment until it is steady at 50km/h. Hold at 50km/h ENTER to Start Press ENTER and the Programmer will start counting pulses. The pulses will be audible as low-pitched clicks. Hold at 50 km/h Reading pulses After about 15 seconds it will emit an audible beep and the measured W-factor will be displayed. If appropriate for the selected tachograph type the measured K-factor and the required DIL switch setting will be displayed. For Stoneridge VR2400/SE5000, Kienzle 1319/DTCO, MotoMeter EGK-100 and Actia Smartach tachographs the required Wfactor will be retained in the Programmer (until the Programmer is turned off) ready for later programming of the tachograph, as described in Chapter 5. W=8000 K=8000 Note: In the case of the message ERROR! CHECK CONNECTIONS being displayed, ensure that the ground connection is made correctly. Otherwise check the other connections. ERROR! CHECK CONNECTIONS DIL=_23_____9_ 4.2.2 Fixed Distance Method No. 1 This method typically uses the 20m measured distance often available at tachograph fitting stations, but it is possible to set to any distance from 20 to 1000m as required. The Fixed Distance Length can be adjusted via the Diagnostics Menu (see Section 2.6). Care must be taken to ensure that the Fixed Distance Length set and the actual track length are the same, otherwise the W-Factor determined will be incorrect. The vehicle is driven along the measured track and measurements made at either end of the track are fed into the Programmer, from which the W-factor is determined. 20 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Notes: 1. This method is only suitable for use where the pulser on the vehicle continues to produce pulses even when the vehicle is moving very slowly. 2. It is not suitable for use with many proximity senders. 3. It is not suitable for use with 80mph scale tachographs. 4. If testing a Kienzle 1319 tachograph, ensure that the km/h scale is selected (see Section 5.4 for details). Procedure A B 20 metre track Pointer Distance 1 Distance 2 To use Fixed Distance Method No. 1 reliably, a method is needed of indicating accurately when the vehicle is at the beginning and end of the measured distance. For the duration of the test some form of pointer should be attached to the vehicle with its pointing end close to the ground. The vehicle is driven such that the pointer passes directly over the marks at either end of the measured distance. It is then much easier to measure the distance between each mark and the point at which the next pulse occurs. When attaching the pointer to the vehicle it is preferable to fix it to a point rigidly attached to the chassis (e.g. the end of the front bumper) and not to the cab which is often sprung. Select FIXED DISTANCE #1 from the Main Menu, and follow the instructions displayed in the step-by-step details of the procedure that follow; Select FIXED DISTANCE #1 on the MAIN MENU (shortcut key 2) using the ← and → keys, and press ENTER. VR8400 MAIN MENU :FIXED DIST #1 21 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Move the vehicle to the beginning of the 20m track (position A) such that the pointer is over the marker at the beginning of the track and then press ENTER. Drive to point A Press <ENTER> Move the vehicle slowly forward until an audible beep is heard indicating that a pulse has been received. Stop the vehicle and press ENTER. <ENTER> when new pulse received Measure in mm the distance just moved by the vehicle from point A. Key this distance into the Programmer as Distance 1 and press ENTER to terminate the entry. Enter Distance 1 : mm Move the vehicle to the end of the 20m track (position B), again so that the pointer is over the marker, and press ENTER. Low-pitched clicks will be heard as the pulses are received. <ENTER> when at position B Move the vehicle slowly forward again until a louder audible beep is heard indicating that a pulse has been received. Stop the vehicle and press ENTER. <ENTER> when new pulse received Measure in mm the distance just moved by the vehicle from point B. Key this distance into the Programmer as Distance 2 and press ENTER to terminate the entry. Enter Distance 2 : mm The W-factor measured for run #1 will be displayed. Press ENTER. End of run #1 W factor = 8005 Repeat steps 2 to 7, this time moving back from point B to point A. Repeat steps 2 to 7 once more in each direction giving a total of two runs in each direction. The measured W-factor will be displayed at the end of each run. After keying in the last distance and pressing ENTER, the W-factor for the last run will be displayed. Press ENTER again and the average of the measured W-factors for the four runs will be displayed, as well as the K-factor. W=8000 K=8000 DIL=_23_____9_ The required W-factor will be retained in the Programmer (until the Programmer is turned off) ready for later programming of the tachograph. 22 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs If appropriate for the selected tachograph type the required DIL switch setting will also be displayed. For Stoneridge VR2400/SE5000 Series, Kienzle 1319/DTCO, MotoMeter and Actia Smartach tachographs the required W-factor will be retained in the Programmer (until the Programmer is turned off) ready for later programming of the tachograph. Note: For best accuracy two runs should be carried out in each direction rather than four in one direction since this will take account of any slight gradient of the track. 4.2.3 Fixed Distance Method No. 2 This method typically uses the 20m measured distance often available at tachograph fitting stations, but it is possible to set to any distance from 20 to 1000m as required. The Fixed Distance Length can be adjusted via the Diagnostics Menu (see Section 2.6). Care must be taken to ensure that the Fixed Distance Length set and the actual track length are the same, otherwise the W-Factor determined will be incorrect. The vehicle is driven along the measured track but all measurements are automatically carried out by the Programmer, which then automatically determines the W-factor. To simplify the measurements at each end of the measured distance a flexi-switch is used which makes contact with a marker at each end of the track. There is then no requirement for any operator intervention - the only requirement is to drive the vehicle the length of the track at a reasonably constant speed (roughly walking pace) such that the flexi-switch hits the markers at either end of the track. Note: this method is not suitable for use with 80mph scale tachographs. If testing a Kienzle 1319 tachograph, ensure that the km/h scale is selected (see Section 5.4 for details). Benefits of Fixed Distance Method No. 2 • Easy to use. No manual intervention required. • Works with all types of pulser including those which stop generating pulses at low speeds. • Cheap to use - avoids the need to invest in a rolling road • Very accurate. The measurement accuracy is significantly greater than that of a rolling road. This method can thus be used to check the accuracy of a rolling road. A B 20 metre track Flexi-Switch End-of-track Markers 23 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Procedure Fixed Distance Method No. 2 requires the vehicle to be driven such that a flexi-switch attached to the vehicle strikes a marker at either end of the fixed track. To maintain the measurement accuracy the flexi switch should be attached to a part of the vehicle rigidly attached to the chassis such as the front bumper. Ideally the flexi-switch should be mounted with its operating lever pointing vertically downwards and the markers should be placed on the ground. Alternatively, the flexi-switch may be mounted with its operating level pointing horizontally to strike against vertical posts. The markers at either end of the track are best implemented using wooden or concrete blocks, ideally about 1m long with sides 100 to 150mm. Steel joist material is particularly suitable. The requirement is to have a marker which will have a well defined point of contact with the flexi-switch and which will not move during the test. Although it is perfectly acceptable to mount the flexi-switch on the side of the vehicle with the markers to the side of the vehicle, some difficulty may be experienced in ensuring that the switch hits the markers repeatedly. A better arrangement is to mount the switch centrally on the front of the vehicle and arrange the markers such that the vehicle passes directly over them. Select FIXED DISTANCE #2 from the Main Menu, and follow the instructions displayed in the step-by-step details of the procedure that follow; Select FIXED DISTANCE #2 on the MAIN MENU (shortcut key 3) using the ← and → keys, and press ENTER. KZ1319 MAIN MENU :FIXED DIST #2 Move the vehicle to a position a short distance before the beginning of the 20m track (position A) such that the flexi-switch lever is in line with the marker at the beginning of the track and then press ENTER. Drive to point A Press <ENTER> Drive the vehicle at a reasonably constant speed past markers at points A and B. A low pitched click will be heard as each pulse is received and, at the same frequency as the clicks, a visual indicator will be displayed as shown. When a marker is passed a louder audible beep will be heard. Drive to point B Reading pulses After the second marker has been passed the Programmer will display the measured Wfactor for that run. Stop the vehicle and press ENTER. End of run #1 W-factor = 8000 . Drive to point B Reading pulses Drive to point B Reading pulses 24 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Repeat steps 2 and 3, this time moving back from position B to position A. Drive to point B Press ENTER Repeat steps 2 and 3 once more in each direction giving a total of two runs in each direction. After passing the last marker the Wfactor for the last run will be displayed. End of run #4 W-factor = 8000 Press ENTER again and the average of the measured W-factors for the four runs will be displayed as well as the K-Factor. If appropriate for the selected tachograph type the required DIL switch setting will also be displayed. W=8000 K=8000 DIL=_23_____9_ Note: For best accuracy two runs should be carried out in each direction rather than four in one direction since this will take account of any slight gradient of the track. The repeatability of the Fixed Distance Calibration No 2 method is such that the effect of a slight gradient of the fixed track is easily measurable. By taking the average of runs in opposite directions the effect of the gradient is removed. 4.3 Bench Test (Connections) Before installation and during recalibration it is necessary to carry out a bench test of the tachograph. This requires the unit to be run at different speeds for different periods of time and with different driver duty modes selected. The Tachograph Programmer provides a test signal simulating the pulser output which gives the required speed outputs for the required times. The only operator intervention is then to set the duty switches at the appropriate times as indicated by the Programmer. Connections During a bench test the Programmer simulates the output from a vehicle speed/distance sender. The harness suitable for connection to the sender input of the tachograph should therefore be selected: Table 3 : Bench Test connections Tachograph Harness Connection Stoneridge VR2400, VR8300 Series C DIN plug to Socket A of Programmer; other end of harness to appropriate connector on rear of tachograph. 25 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Stoneridge VR8400 Series and Kienzle 1318 Series C or G+S+J As above or Jack plug of harness G to socket of harness S and jack plug of S to socket inside tachograph DIN plug of harness G to Programmer socket A; Use Crocodile clip J to make required ground connection to a suitable point on the vehicle. Kienzle 1319 Series C or G+O+J As above or Jack plug of harness G to socket of harness O and 8-way connector to socket on tachograph DIN plug of harness G to Programmer socket A; Use Crocodile clip J to make required ground connection to a suitable point on the vehicle. Stoneridge VR1400 Series K DIN plug to Socket A of Programmer; other end of harness to appropriate connector on rear of tachograph and to vehicle sender. Kienzle 1314 Series L or G+T+J DIN plug to Socket A of Programmer; other end of harness to appropriate connector on rear of tachograph and to vehicle sender. Or Jack plug of harness G to socket of harness Tand jack plug of S to socket inside tachograph DIN plug of harness G to Programmer socket A; Use J to make a suitable ground connection Kienzle1324 Series O or C DIN plug to socket A of Programmer; other end of harness to appropriate connector on rear of tachograph and to vehicle sender. Or DIN plug to Socket A of Programmer; other end of harness to appropriate connector on rear of tachograph. Motometer EGK100 C+ adapter M or N DIN plug of harness C to Socket A of Programmer; other end to appropriate connector on rear of tachograph through adapter M. Or one end of N to socket C on Programmer and other end to Socket on Tachograph. SE5000/DTCO/ Smartach Z DIN plug to programmer socket C. Other end to D-shaped socket on front of tachograph. 26 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Procedure The Bench Test routines in the MKII Tachograph Programmer are designed to lead the operator through the test without reference to other documents and wherever possible to automate the tasks. The Bench Test is carried out with the tachograph removed from or in the vehicle. Standard UK, French, German, Swedish, Dutch, Belgian tests, or a Custom test are available. A Bench-Test Type can be selected via the Diagnostics Menu (see Section 2.6 for details). Note that the bench test procedure used for the digital tachographs varies from other tachograph types. For step-by-step details of the different Bench-test procedures see Annex B. 4.4 Distance Test The Distance Test function is used to test the accuracy of the distance recording by injecting pulses simulating a distance travelled of 1000m. The distance test is specific to the SE5000, DTCO and Smartach tachographs. Select Distance Test from the MAIN MENU and press ENTER SE5000 MAIN MENU :DISTANCE TEST At the beginning of the test the odometer (High Resolution Total Vehicle Distance) of the tachograph is read and stored in the programmer. Reading data Find the K-factor that the tachograph is currently set to. Press the DELETE key, and key this value into the Programmer. Then press ENTER. Select K-factor The programmer sends a message to allow speed pulses to be output through the front of the tachograph. If the Tachograph is already in Calibration Mode (or if it is non-activated) the PIN will NOT be requested. If the Programmer is not in Calibration mode, the workshop card should be inserted into the tachograph and the PIN code entered. Sending data Speed pulses are output to simulate 50km/h for 72 seconds Speed: 50 km/h Time: 72s At the end of the test the odometer (High Resolution Total Vehicle Distance) of the tachograph is read and stored in the programmer. Reading data The total distance the tachograph has recorded is then calculated, and the accuracy displayed (to +/- 1%) Distance = 1000m +0% :8000 Pul/km? 27 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs 4.5 Speed Simulator The speed simulator function is used to inject speed pulses into the tachograph. This can be used to check the accuracy of the tachograph speed pointer or speed stylus position. The final distance displayed also enables the tachograph odometer to be checked. When the tachograph is still fitted in the vehicle, the speed simulator function is also useful for verifying the operation of speed or distance related ancillaries such as the Road Speed Limiter. Connections These are the same as for the connections for the Bench test (see Table 3 in section 4.2). Additionally, the pulses can be injected into the front of tachographs still fitted in the vehicle but only if the engine is switched off (connections in this case are the same as for the K-factor Test see Table 10 in section 4.12). Procedure Select SPEED SIMULATOR from the Main Menu, and follow the instructions displayed in the stepby-step details of the procedure that follow; Select SPEED SIMULATOR from the MAIN MENU and press ENTER VR2400 MAIN MENU :SPEED SIMULATOR Find the K-factor that the tachograph is currently set to. Press the DELETE key, and key this value into the Programmer. Then press ENTER. Instructions for determining the K-factor are given in section 4.12 Select K-factor Key in the speed required and press ENTER. Note that there is a minimum detectable speed for each tachograph type, which depends on the K-factor but may be up to 20km/h. Below this, the speed will reset to 0km/h. Enter speed The Programmer will now inject speed pulses into the tachograph. K=8000 Pul/km :8000 Pul/km? : km/h Speed=50 km/h Use the ↑ and ↓ (7 and 4) keys to increase or reduce speed. K = 8000 Pul/km When done press ENTER. The unit will now display the total distance covered (in metres). Distance=1090 m Speed=51 km/h Press <ENTER> Press ENTER to key in a new speed or MENU to return to the MAIN MENU. VR2400 MAIN MENU :SPEED SIMULATOR 28 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs 4.6 Revs per minute pulse test When fitting a tachograph which records engine speed (i.e. 4-stylus or EVENT tachograph) it is necessary to determine the number of pulses received by the tachograph for each revolution of the engine. The tachograph can then be programmed accordingly. Connections Table 4 : RPM Pulse Test connections Tachograph Harness Connection Stoneridge and Kienzle 4-stylus models E DIN plug to Socket A of Programmer; remove the existing plug from socket C on the tachograph and connect it to the harness socket; (remove the grey seal for VR8300 and VR8400 models) Kienzle 1324 Series Connect the red harness plug to socket C on rear of tachograph. W DIN plug to socket C on Programmer. D-shaped connector tachograph Motometer EGK100 G+ adapter Q + clip J to socket on front of DIN plug of harness G to Socket A of Programmer; jack to socket D on rear of tachograph through adapter Q. Note that the tachograph is not in the circuit. Use Crocodile clip J to make required ground connection to a suitable point on the vehicle. Procedure Select RPM PULSE TEST from the Main Menu, and follow the instructions displayed in the stepby-step details of the procedure that follow; From the MAIN MENU select RPM PULSE TEST (shortcut key 5). VR8400 MAIN MENU :RPM PULSE TEST Start the vehicle engine and run it at 1000 rpm. Hold 1000 RPM ENTER to start Whilst holding 1000rpm press ENTER on the Programmer. The unit will indicate Reading pulses. Hold 1000 RPM Reading pulses 29 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs At the end of the test the measured PPR value will be displayed. End of RPM test PPR = 8.0 Press ENTER or MENU to return to the MAIN MENU. VR8400 MAIN MENU :RPM PULSE TEST 4.7 Clock Test Most Benchtest procedures include the requirement to check the accuracy of the internal clock. There are two different methods of determining the clock accuracy of Tachographs, and these two methods are described as follows. 4.7.1 Clock Test – Motometer, Stoneridge VR2400/SE5000, Kienzle 1324/DTCO and Actia Smartach When checking one of the above tachograph types, the accuracy of the internal clock may be checked as described in this Section. It is also very important with the 2400 to check that the chart is in synch with the internal clock once the clock has been checked. Connections Table 5 : Clock Test Connections (2400, SE5000, 1324, DTCO, EGK100 and Smartach) Tachograph Harness Connection Stoneridge VR2400 Series U DIN plug to socket C on the Programmer and the Dshaped connector to the socket inside the front of the tachograph Kienzle 1324 W DIN plug to socket C on the Programmer and the Dshaped connector to the socket on the front of the tachograph Motometer EGK-100 N One end to socket C on Programmer and other end to Socket on tachograph SE5000/DTCO/ Smartach Z DIN plug to programmer socket C. Other end to Dshaped socket on front of tachograph. Procedure Select CLOCK TEST from the Main Menu, and follow the instructions displayed in the step-by-step details of the procedure that follow; 30 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs 4.7.2 From the MAIN MENU select CLOCK TEST (shortcut key 4) using the ← and → keys. Press ENTER to start the test. EGK100 MAIN MENU :CLOCK TEST The Programmer will display the message Testing clock. Testing clock After a few moments the clock accuracy in seconds per day will be displayed. Clock Accuracy +0.2s/day In the case of lack of signal from the tachograph (caused by such as a faulty connection to the tachograph), the Programmer will display an error message. ERROR! No signal Press <ENTER> Clock Test – Stoneridge VR8400/8300 Series and Kienzle 1314/1318/1319 Connections Clock Tester to Programmer socket C. Set both duty knobs to Rest. Ensure that the tachograph is powered and the speed pointer is at rest. Hold the adapter against the tachograph face, and move it around until it makes a regular clicking sound - this is the correct location. Please note that the correct location is not necessarily near the clock face, as the Tester detects the clock motor (this is why the duty knobs must be at Rest and the pointer at zero - otherwise the Tester may detect the chart motor instead of the clock motor). Similarly, the Tester must not be within 12 inches of a mains transformer. Procedure Select CLOCK TEST from the Main Menu, and follow the instructions displayed in the step-by-step details of the procedure that follow; From the MAIN MENU select CLOCK TEST (shortcut key 4) using the ← and → keys. Hold the Tester at the correct location on the Tachograph face (as described above). Press ENTER to start the test. KZ1314 MAIN MENU :CLOCK TEST The Programmer will display the message Testing clock, and will make a regular clicking sound. Testing clock After a short time the clock accuracy in seconds per day will be displayed. Clock Accuracy +0.2s/day In the case of loss of signal or inconsistent signal from the tachograph (usually caused by movement of the Tester away from the clock motor), the Programmer will display an error message. ERROR! No signal Press <ENTER> 31 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs 4.8 Pair/Test Tacho. This function allows several functions in the tachograph to be tested, such as; Display Test, LCD negative, Printer Test, Hardware Test, Card Reader, Button Test. This function also allows the Sender to be paired. Select PAIR/TEST from the main menu and press ENTER. SE5000 MAIN MENU :PAIR/TEST Use the ← and → to select the test you wish to perform, and press ENTER to start the test. PAIR/TEST :Display Test Note : The tachograph has to be in calibration mode (or non-activated). If the tachograph is unable to perform a test for some reason, the programmer will respond with ‘Transfer FAIL’. The programmer will monitor the progress of the test. Sending Data … At the end of the test the ‘Data Transfer OK’ message should be displayed. Sending Data Data Transfer OK 4.9 Tacho Control For the Stoneridge VR8400 series, this menu option can be used to initiate the Self Test or Extended Test modes of the tachograph. It can also be used to reset the tachograph memory to the default state. For the Stoneridge VR2400, this can be used to reset the tachograph or pair the sender. For the Kienzle 1324 Series, this can be used to pair the sender. Connections Table 8 : Tacho control Connections Tachograph Harness Connection Stoneridge VR2400 Series U 8-pin DIN to socket C on the programmer and the D-shaped connector to the socket inside the front of the tachograph. Stoneridge VR8400 Series G 5-pin DIN plug to socket A on the Programmer. Connect the jack plug to the jack socket inside the front of the tachograph. A ground connection is also needed to the harness black wire. Clip J may be used to aid connection to a suitable vehicle ground point. Kienzle 1324 W The 8-pin DIN plug to socket C on the Programmer and the D-shaped connector to the socket on the front of the tachograph 32 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Procedure Select TACHO CONTROL from the Main Menu, and follow the instructions displayed in the stepby-step details of the procedure that follow; Select TACHO CONTROL on the MAIN MENU by using the ←and → keys, and press ENTER. VR 2400 MAIN MENU :CONTROL MENU From the CONTROL MENU make the required selection - using the arrow keys ←and → to select Reset Tacho or PAIR SENDER. Press ENTER to send the instruction to the tachograph. CONTROL MENU : Pair Sender In the case of Reset Defaults, the programmer will cause the tachograph to simulate a Power Off/On Condition. CONTROL MENU :Reset Defaults In the case of pair sender, press ENTER and the sender will pair automatically within 60 seconds. Sending data Data transfer OK Note: When paired to the encrypted sender, the tachograph recognises only that sender. The signal from the sender becomes unique to that tachograph. 4.10 Identify Tacho – Stoneridge VR2400/SE5000 Series, Kienzle 1324/DTCO and Actia Smartach This function interrogates Stoneridge VR2400/SE5000, Kienzle 1324/DTCO or Actia Smartach tachographs via the K-line. Parameters that can be determined are the System supplier, Manufacture date, Serial number and Hardware version (all tachograph types) and Software number, Software version and System name (all VR2400/SE5000 only). Connections Connect either Cable U between the Programmer and VR2400 Tachograph front connector, or Cable W between the Programmer and the 1324 Tachograph front connector, or Cable Z between the Programmer and the SE5000/DTCO/Smartach Tachograph front connector. Procedure Select IDENTIFY TACHO from the Main Menu, and follow the instructions displayed that follow; From the VR2400 MAIN MENU use the ← and VR2400 MAIN MENU 33 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs → keys to select IDENTIFY TACHO. :IDENTIFY TACHO Press ENTER and the Programmer interrogates the VR2400 tachograph. Use the ← and → keys to scroll through the available options. 4.11 Read/Erase DTCs – Stoneridge VR2400/SE5000 Series, Kienzle 1324/DTCO and Actia Smartach This function enables the Diagnostic Trouble Codes in the tachograph to be displayed on the Programmer and then erased from the Tachographs memory if required. For a full list of VR2400 Tachograph DTCs please see Annex C. Connections Table 9 : Read/Erase DTCs Connections Tachograph Harness Connection Stoneridge VR2400 Series U 8-pin DIN to socket C on the programmer and the D-shaped connector to the socket inside the front of the tachograph. Kienzle 1324 W The 8-pin DIN plug to socket C on the Programmer and the D-shaped connector to the socket on the front of the tachograph SE5000/DTCO/Smartach Z The 8-pin DIN plug to socket C on the Programmer and the D-shaped connector to the socket on the front of the tachograph Procedure Select Read/Erase DTCs from the Main Menu, and follow the instructions displayed in the step-bystep details of the procedure that follow; Select READ/ERASE DTCS on the MAIN MENU by using the ←and → keys, and press ENTER. VR 2400 MAIN MENU :READ/ERASE DTCS If no connection is made, an error Message will be displayed, before returning to the Main Menu. TRANSFER FAILURE If the connections are made, the programmer will read the DTCs data from the Tacho and messages will be displayed to indicate this. Reading Data Please Wait 34 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs (2400 and 1324 tachographs) A typical DTC screen will then be displayed. DTC=A423 Cnt=1 14:42 10/07/2003 Use the ↑ and ↓ (7 and 4) keys to check all the other DTCs stored. Press the DELETE key to delete individual DTCs stored (Note: this function VR2400 only) (SE5000/DTCO tachograph) A typical DTC screen will then be displayed. 002004 Cnt=1 14:42 03/02/2005 Use the ↑ and ↓ (7 and 4) keys to check all the other DTCs stored. Press the DELETE key to delete individual DTCs stored. (Smartach tachograph) DTC= 00200708 A typical DTC screen will then be displayed. Use the ↑ and ↓ (7 and 4) keys to check all the other DTCs stored. Press the MENU key to display the message shown. Press <ENTER> to clear DTCs Press the ENTER key to delete all stored DTCs or the MENU key to return to the Main Menu without deleting any of the DTCs. 4.12 K-Factor Test This provides a simple way of determining the K-factor currently set on a tachograph. The test is applicable to Stoneridge VR8400 and Kienzle 1314, 1318 and 1319 ranges of tachograph. Note: with VR2400, SE5000, DTCO, 1324 and Smartach tachographs the K-factor can be read directly using Read All Data (see Section 5 for details). Connections Table 10 : K-factor Test Connections Tachograph Harness Connection Stoneridge VR8400 Series, Kienzle 1318 G+ clip J Jack plug of harness G to socket inside front of Tachograph. DIN plug of harness G to Programmer socket A; Use Crocodile clip J to make required ground 35 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Tachograph Harness Connection connection to a suitable point on the vehicle Kienzle 1314 G+ clip J Jack plug of harness G to socket inside front of Tachograph; DIN plug of harness G to Programmer socket A; Use Crocodile clip J to make required ground connection to a suitable point on the vehicle Kienzle 1319 O+ G+ clip J 4-pin rectangular connector of harness O to socket inside front of Tachograph; other end to harness G. The 4-pin connector will fit either way up, but only one orientation is correct - this is indicated as a small cross marked on the connector. When inserting the adapter, the cross should face upwards; DIN plug of harness G to Programmer socket A; Use Crocodile clip J to make required ground connection Procedure Select K-FACTOR TEST from the Main Menu, and follow the instructions displayed in the step-bystep details of the procedure that follow; From the MAIN MENU select K-FACTOR TEST (shortcut key 6) using the ← and → keys. VR 8400 MAIN MENU :K-FACTOR TEST Press ENTER. The Programmer will first display Sending pulses, please wait. Sending pulses Please wait After a few moments the Programmer will beep, and then display the K-factor setting of the tachograph. If the K-factor is different from the previous test, then the Programmer will beep and display “<>“. Sending pulses K = 8000 Step 3 will then repeat until the MENU or ENTER button is pressed. Three repetitions are recommended. Sending pulses K = 8000 If a significantly different K-factor (>10 pulses/km difference) is displayed, this usually indicates a cable fault or bad connection. It may also be due to a faulty tachograph. Note: In the case of the message ERROR! CHECK CONNECTIONS being displayed, ERROR! CHECK 36 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs ensure that the ground connection is made correctly. Otherwise check the other connections. CONNECTIONS 4.13 DIL Calculate For the Stoneridge VR8400/8300/1400 and Kienzle 1318 tachographs the K-factor is set using a bank of 10 DIL switches (except the VR1400, which has 8). The DIL Calculate function determines the appropriate combination of switches for any K-factor, thus avoiding the need to use calibration tables. If a tachograph type has been selected which does not use DIL switches for calibration then this menu option is not available. Connections No connections are required whilst calculating the appropriate DIL switch settings. Procedure Select DIL CALCULATE from the Main Menu, and follow the instructions displayed in the step-bystep details of the procedure that follow; From the MAIN MENU select DIL CALCULATE using arrow keys ← → and press ENTER. VR8400 MAIN MENU :DIL CALCULATE With the unit display as shown, press ENTER. W=8000 K=8000 DIL = _23_____9_ The W-factor of the vehicle may then be entered using the numeric keys; terminate the entry by pressing ENTER again. Enter W-factor : Note: W-factor determination functions are described in section 4.1. The exact K-factor setting will be displayed, together with the required settings of the DIL switches. W=5000 K=5002 DIL = 12___6_89_ Time / Date. This function allows the time and date to be set in the tachograph, but outside the normal calibration procedure. This test is applicable for the SE5000, DTCO and Smartach tachographs only. 4.14 37 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs 5. Select TIME/DATE from the main menu and press ENTER. SE5000 MAIN MENU :TIME/DATE Current time - Press ENTER and a cursor will flash. Key in the current time and press ENTER. Current time :10:35 Current date - Press ENTER and a cursor will flash. Key in the current date and press ENTER. Current date :19/10/2003 Time offset - Press ENTER and use the up/down arrow keys to choose a time offset between +23:00 and –23:00 hours and +59 and –59 minutes. Time offset :+1: +00 Press the Send key to send the data to the tachograph. Sending data PROGRAMMING A TACHOGRAPH The method of programming a tachograph varies according to the type of tachograph. For earlier types of electronic tachograph, programming is generally carried out using internal DIL switches. Later types require an external Programmer to set some or all of the required parameters. Of the types requiring an external Programmer, the MKII Tachograph Programmer supports programming of the Stoneridge VR8400/2400/SE5000 series, Kienzle 1319/1324/DTCO series, MotoMeter EGK-100 and Actia Smartach tachographs. Note that in all cases the instructions suggest that, once settings have been altered, the SEND ALL DATA (shortcut key 9) command be used to transfer all the information at the end. It is, however, possible to send each individual setting after alteration by pressing the SEND key (except Kienzle 1319, EGK-100 and Smartach). 5.1 Programming Stoneridge VR8400 Series tachographs Parameters which may be programmed • Pulses Per engine Revolution (PPR) setting • Ignition-on recording • Low power Band • Overspeed • Economy band • Poor Economy Connections Table 11: VR8400 series Programming connections 38 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Tachograph Harness Connection Stoneridge VR8400 Series G+J DIN plug to Programmer socket A; Jack plug to socket inside front of tachograph Crocodile clip to make required ground connection to a suitable point on the vehicle, or to the negative connection of the tachograph power supply. Procedure for Standard and Engine Speed (RPM) Recording Versions From the MAIN MENU select PROGRAM TACHO and press ENTER. VR8400 MAIN MENU :PROGRAM TACHO Pulses per Rev - Press ENTER and the cursor will appear on the display. Use the numeric keys to enter the required value. This is usually 8 pulses per rev. Pulses per Rev :8 Engine Speed Recording - Select each of the engine speed recording bands (Low Power, Economy and Poor Economy) in turn. Press ENTER and characters ← → will appear. Use the ← and → keys to select the required value and terminate by pressing ENTER. Low Power band :700 Revs/min Note: that the Programmer will not allow entry of inconsistent engine speed bands. For example, the user may not set a minimum speed for the Economy band which is lower than the speed defined for the Low Power band. Economy band :900 Revs/min Poor Economy :1100 Revs/min Ignition On Record - Press ENTER and ← → will appear on the display. Use the ← or → keys to select ON or OFF and press ENTER to terminate the selection. Ign On Record :OFF Overspeed - Press ENTER and a cursor will flash. Key in the required overspeed value and terminate the entry by pressing ENTER. Overspeed :80 km/h Select SEND ALL DATA (shortcut key 9) from the main menu and press ENTER. VR8400 MAIN MENU :SEND ALL DATA Send All Data When programming the tachograph, the values may be entered in turn, and then all sent to the tachograph at once. 39 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs 5.2 From the MAIN MENU select SEND ALL DATA (shortcut key 9) and press ENTER. VR8400 MAIN MENU SEND ALL DATA Press ENTER to confirm that you wish to reprogram the tachograph, or MENU to cancel. Are you sure? ENTER to program Select the required scale type and press Enter. Options are: 125km/h,140km/h, 80mph, 160km/h. Select the scale :125 km/h ← → On completion of the data transfer the Programmer will emit an audible beep and will indicate Data Transfer OK. Sending data Data transfer OK Programming Stoneridge VR2400 Series tachographs Parameters which may be programmed Please note to select the SENDER TYPE option in the VR2400 MAIN MENU select the PULSER SELECT option (see section 2.9 for details). • K-factor • CANBus enabled • Pin D4 Function • Odometer reading • Customer Type • Low Speed Limit • Pulses per engine Revolution • Dual Axle • Kline Speedo • Engine Speed Recording • Dual Axle Ratio • Current date • CANBus RPM • Speedo OP factor • Time Offset • RPM display • D6 pin function • Output shaft factor • Odo leading 0s • Serial comms • 4 chart trace • Overspeed flash • Ign On Record • Service Delay • DTCs enabled • Crew auto duty • Install date • Overspeed • 7 day eject PIN • Reset Heartbeat • Current time • VIN • Analogue Revs th • 2400 Programming Connections Table 12: 2400 series Programming connections Tachograph Harness Connection 40 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs 2400 U Connect DIN plug to socket C on the Programmer and the Dshaped connector to the socket inside the front of the tachograph Procedure Select READ ALL DATA (shortcut key 7) from the main menu and press ENTER. VR2400 MAIN MENU :READ ALL DATA Select MODIFY DATA (shortcut key 8) from the main menu and press ENTER. VR2400 MAIN MENU :MODIFY DATA Use the ← and → to select the parameter you wish to alter. K-factor - Press ENTER and type in the new value. Press enter again to confirm the value. K-factor :8000 Odometer reading - Press ENTER and key in the required new odometer reading. Bear in mind that the last digit entered is the tenths digit, thus a required reading of 100.0km should be entered as 1000. Odometer :0001235.0 Pulses Per engine Revolution - Press ENTER and a cursor will flash. Key in the required PPR value and press ENTER. Bear in mind that the last three digits are thousandths and the number 19.000 must be typed in as 19000. Pulses per Rev :19.000 Engine Speed Recording - Select each of the engine speed recording bands (Low Power, Economy and Poor Economy) in turn. Press ENTER and characters ← → will appear. Use the ← and → keys to select the required value and terminate by pressing ENTER. Low Power band :700 Revs/min Note: that the Programmer will not allow entry of inconsistent engine speed bands. For example, the user may not set a minimum speed for the Economy band which is lower than the speed defined for the Low Power band. Economy band :900 Revs/min Poor Economy :1100 Revs/min CANBus RPM - Press ENTER and use the ← and → keys to select ON or OFF. Press ENTER to confirm the selection. CANBus RPM :Off ← → RPM display - Press ENTER and use the ← and → keys to select ON or OFF. Press ENTER to confirm the selection RPM display :Off ← → 41 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Odo leading 0s - Press ENTER and use the ← and → keys to select ON or OFF. Press ENTER to confirm the selection Odo leading 0s :Off ← → Overspeed flash - Press ENTER and use the ← and → keys to select ON or OFF. Press ENTER to confirm the selection Overspeed flash :Off ← → DTCs enabled - Press ENTER and use the ← and → keys to select ON or OFF. Press ENTER to confirm the selection DTCs enabled :Off ← → Overspeed - Press ENTER and a cursor will flash. Key in the required over speed value and press ENTER. Overspeed :100 km/h Current time - Press ENTER and a cursor will flash. Key in the current time and press ENTER. Current time :10:35 The time can also be set via the keys on the fascia of the 2400 tachograph. Current date - Press ENTER and a cursor will flash. Key in the current date and press ENTER. The date can also be set via the keys on the fascia of the 2400 tachograph. Current date :19/10/2000 Time offset - Press ENTER and use the up/down arrow keys to choose a time offset between +23:00 and –23:00 hours. Time offset :+1:00 Output shaft factor - It is not necessary to change this value. O/P shaft factor :8.140 th 4 Chart Trace - Press ENTER and use the ← and → keys to select ON or OFF. 4th chart trace :Off ← → Press ENTER to confirm the selection CANBus enabled - Press ENTER and use the ← and → keys to select ON or OFF. Press ENTER to confirm the selection CANBus enabled :Off ← → Customer Type - Press ENTER and use the ← and → keys to select the Customer type required. Press ENTER to confirm the selection. Options are: ISO, Renault, Scania, MAN, DC, Ford, VW, DAF, Volvo Bus and Volvo AH. Customer type :ISO ← → Dual axle - Press ENTER and use the the ← and → keys to select ON or OFF. Press ENTER to confirm the selection. Dual axle :Off 42 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Dual Axle Ratio - Press ENTER and type the value of the Dual Axle Ratio required. Dual axle ratio :1.3750 Press ENTER to confirm the selection Speedo OP factor - Press ENTER and a cursor will flash. Speedo OP factor :4971 Key in the required value and press ENTER. D6 pin function - Press ENTER and use the ← and → keys to select OFF, Revs warning or Speedometer. D6 pin function :OFF Serial comms - Press ENTER and use the ← and → keys to select Standard data or Extended data. Serial comms :Standard data Ignition on Record - Press ENTER and use the the ← and → keys to select ON or OFF. Press ENTER to confirm the selection. Ign On Record :Off ←→ Crew auto duty - Press ENTER and use the the ← and → keys to select ON or OFF. Press ENTER to confirm the selection. Crew auto duty :Off ←→ 7 day eject PIN - Press ENTER and type the PIN. This must be 4 digits long. Press ENTER to confirm the selection, (for non EU use only). 7 day eject PIN :0000 VIN - Press ENTER and type the Vehicle Identification Number. This can be up to 17 characters long. Press ENTER to confirm the selection. VIN :1234567890ABCDEFG Service delay - Press ENTER and a cursor will flash. Key in the number of WEEKS left until compulsory recalibration of the tachograph and press ENTER. Service delay :104 weeks Install date - Press ENTER and a cursor will flash. Key in the date of installation of the tachograph and press ENTER. Install date :25/09/2001 Reset Heartbeat - Press ENTER and use the ← and → keys to select ON or OFF. Press ENTER to confirm the selection. Reset Heartbeat :Off ←→ ←→ Note: when set to ON the vehicle cluster presence is confirmed by the tachograph. Analogue Revs - Press ENTER and use the ← and → keys to select ON or OFF. Analogue Revs :On ←→ Press ENTER to confirm the selection. 43 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Pin D4 Function - Press ENTER and use the ← and → keys to select the Pin D4 function required. Pin D4 Function :Off ←→ Press ENTER to confirm the selection from: Off, Dynafleet, Low Speed, Functions, DTC Warning and Chart Change. Low Speed Limit - Press ENTER and a cursor will flash. Key in the required low speed value and press ENTER. Low Speed Limit :5 km/h Kline Speedo - Press ENTER and use the ← and → keys to select the Kline Speedo function required. Press ENTER to confirm the selection. Options are: Off or On. Kline Speedo :Off ←→ Send all data Once the new information has been entered into the programmer, it must be sent to the tachograph to replace the old settings. Select SEND ALL DATA (shortcut key 9) from the main menu and press ENTER. 5.3 VR2400 MAIN MENU SEND ALL DATA Programming Kienzle 1324 Series tachographs Parameters which may be programmed • Odometer reading • Time offset • VIN • Install date • Output shaft factor • CANBus Type • Current time • W-factor • Service delay • Current date • K-factor • L-Factor Connections Table 13: Kienzle 1324 Programming connections Tachograph Harness Connection KZ1324 Series W DIN plug to socket C on Programmer and D-shaped connector to socket on front of tachograph. Procedure Select READ ALL DATA (shortcut key 7) from the main menu and press ENTER. KZ1324 MAINMENU :READ ALL DATA 44 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Select MODIFY DATA (shortcut key 8) from the main menu and press ENTER. KZ1324 MAIN MENU :MODIFY DATA Use the ← and → keys to select the parameter you wish to alter. Odometer reading - Press ENTER and key in the required new odometer reading. Bear in mind that the last digit entered is the tenths digit, thus a required reading of 100.0km should be entered as 1000. Odometer :100.0 Install date - Press ENTER and a cursor will flash. Key in the date of installation of the tachograph and press ENTER. Install date :19/09/2001 Current time - Press ENTER and type in the time in the format shown. Press ENTER to confirm Current time: :13:45 Current date - Press ENTER and type in the date in the format shown. Press ENTER to confirm Current date :25/09/2001 Time offset - Press ENTER and use arrow keys to set the time offset. Time offset :+1:00 The range is +23 to –23 hours. Press ENTER to confirm. Output shaft factor - Press ENTER and type in the required number. Bear in mind that the last three digits are thousandths and that the number 65.500 must be typed in as 65500. Press ENTER to confirm. O/P shaft factor :65.525 W-factor - Press ENTER and type in the number. Press ENTER to confirm. W-factor :8345 K-factor - This is Read Only and cannot be modified with the MKII Programmer. K-factor :8000 Pul/km VIN - Press ENTER and type the Vehicle Identification Number. This can be up to 17 characters long. VIN :1234567890ABCDEFG Press ENTER to confirm the selection. CANBus Type - Press ENTER. Enter the 2 digit code that corresponds to the tachograph type. 00 - OFF, 01 - 50ms, 02 -10ms or 03 20ms. CANBus Type :01 45 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Press ENTER to confirm the selection. Service delay - Press ENTER and a cursor will flash. Key in the number of WEEKS left until compulsory recalibration of the tachograph and press ENTER. Service delay :104 weeks L-Factor - Press ENTER and a cursor will flash. Key in the circumference of the vehicle wheel in mm and press ENTER. L-Factor :3000 mm Send all data Once the new information has been entered into the programmer, it must be sent to the tachograph to replace the old settings. Select SEND ALL DATA (shortcut key 9) from the main menu and press ENTER. 5.4 KZ1324 MAINMENU SEND ALL DATA Programming Kienzle 1319 Series tachographs Parameters which may be programmed • K-factor • Odometer reading • Over speed limit • Speed units (km/h or mph) • Calibration station Identifier • Calibration date • Installation date • Tachograph clock speed Connections Select harness P. Connect the 8-pin DIN plug to the Programmer socket C. Remove the seal and the cover over the connector on the front of the tachograph. Connect the other end of the harness to the pair of connectors on the front of the tachograph. 46 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Procedure Read the current tachograph setting prior to making changes. From the MAIN MENU select using arrow keys READ ALL DATA (shortcut key 7) and then press ENTER to read data from the tachograph. KZ1319 MAIN MENU :READ ALL DATA When the Programmer indicates that the data has been received return to the MAIN MENU and this time select MODIFY DATA (shortcut key 8) using the ← → arrow keys. Press ENTER. KZ1319 MAIN MENU :MODIFY DATA Select the parameters to be changed. Press the ← or → keys to move between the parameters to be entered. K-factor - Again press ENTER to change the current value and enter the new value which was stored during the W-factor measurement (described in Section 4.1). For Kienzle 1319 tachographs, the K-factor is remembered until the Programmer is switched off or the K-factor is changed. K-Factor :52356 Odometer reading - Press ENTER and key in the required new odometer reading. Bear in mind that the last digit entered is the tenths digit, thus a required reading of 100.0km should be entered as 1000. Odometer :0001234.5 Over speed - Press ENTER and key in the required new overspeed limit. Over Speed :100km/h Speed Units - Press ENTER and the characters <> will appear. Select km/h or mph using the ← and → keys and then press ENTER. Speed units :km/h Calibration station Identifier - This is an alphanumeric string identifying the station carrying out the calibration. Calib. Ident. :SE #1234 Press ENTER and a cursor will flash indicating which character is being changed. Press the key with the required letter a number of times to get the character. Use the arrow keys to move between characters. Terminate the entry by pressing ENTER. Note: that a default Calib. Ident. string may be programmed into the Programmer. After selecting Calib. Ident. and pressing ENTER thus causing the cursor to flash, pressing DELETE will enter the default string and terminate the entry. 47 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Calibration Date - key in the calibration date in numeric format, e.g. for 25 September 2001 enter 250901. Calib. Date :25/09/01 Installation Date - key in the calibration date in numeric format, e.g. for 24 September 2001 enter 240901. Install Date :24/09/01 Tachograph Clock Speed - Press ENTER and <> will appear on the display. Using the ← and → keys select either Normal or Fast clock speed. Fast clock speed increases the rate of rotation of the chart for test purposes. Clock speed :Normal Note: Ensure that the clock speed is returned to normal at the end of the test and before sealing the tachograph. Having entered the values to be programmed into the tachograph, return to the MAIN MENU by pressing menu button and now select SEND ALL DATA (shortcut key 9). KZ1319 MAIN MENU :SEND ALL DATA 48 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs 5.5 Programming MotoMeter EGK-100 tachographs Parameters which may be programmed • K-factor • Pulses per engine revolution Engine speed recording bands • Connections Select harness N. Connect one end of the harness to socket C on the Programmer. Connect the other end to the 8-pin connector on the front of the tachograph. Procedure If appropriate read the current tachograph setting prior to making changes. EGK100 MAIN MENU :READ ALL DATA From the MAIN MENU select READ ALL DATA (shortcut key 7) using the arrow keys ← →, and then press ENTER to read data from the tachograph. When the Programmer indicates that the data has been received return to the MAIN MENU and this time select MODIFY DATA (shortcut key 8) the arrow keys, and press ENTER. EGK100 MAIN MENU :MODIFY DATA Select the parameters to be changed. Press the ← or → keys to move between the parameters to be entered. EGK100 MAIN MENU :READ ALL DATA K-factor - Again press ENTER to change the current value and enter the new value that was stored during the W-factor measurement. K-factor :8000 Pulses per engine revolution - Press ENTER and key in the new value. For the MotoMeter tachograph values between 20.0 and 30.0 are valid. A 3-digit number should be entered, and on completion of the entry (press ENTER) the Programmer will insert a decimal point between the last two digits. Pulses per Rev :20.8 49 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Engine speed recording bands - In each case press ENTER to change the current value and enter the new value. Note: the Programmer will not allow the user to enter inconsistent engine speed bands. For example, the minimum speed for the Economy band must be higher than the speed defined for the Low Power band. Low Power band :900 Economy band :1400 Poor Economy :1600 Having entered the values to be programmed into the tachograph, return to the MAIN MENU by pressing Menu button and now select SEND ALL DATA (shortcut key 9) by pressing the arrow keys. EGK100 MAIN MENU :SEND ALL DATA As instructed on the display, press ENTER to send the data. On completion of the data transfer the Programmer will indicate Data Transfer OK. Sending Data Data Transfer OK In the event of a problem, the message Transfer FAILURE will be displayed. In that event check the harness connection. Transfer FAILURE 50 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs 5.6 Programming SE5000 Series tachographs Parameters which may be programmed • K-Factor • Tyre Size • Eng. Speed Rec. • Odometer • Next Calib. Date • VRESD • Current time • Veh. Reg. Nation • Veh. Speed Rec. • Current date • VRN • VRVSD • Time Offset • Speed Authorised • D5 pin function • Output Shaft Factor • Illum. Input • CAN trip reset • CANBus enabled • Revs Inp. C3/CAN • Pre-Overspeed • Speedo O/P Factor • Pref. Language • Pre-NextCalib • D6 pin function • CANBus type • Display Function • VIN • D7 pin function • Max.Warranty • Service delay • Serial Data Out • War.Valid Time • Install Date • Backlight Select • Warranty Time • Reset Heartbeat • Illumination Lvl • No. writes WT • D4 pin function • Illumination Off • Activation Time • Low Speed Limit • RPM Factor • W-factor • L-Factor • CAN Termination • Add. Event Rec. 51 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Connections Table 13: Stoneridge SE5000 Programming connections Tachograph Harness Connection SE5000 Series Z DIN plug to socket C on Programmer and D-shaped connector to socket on front of tachograph. Procedure Select READ ALL DATA from the main menu and press ENTER. SE5000 MAIN MENU :READ ALL DATA Select MODIFY DATA from the main menu and press ENTER. SE5000 MAIN MENU :MODIFY DATA Use the ← and → to select the parameter you wish to alter. K-factor - Press ENTER and type in the new value. Press enter again to confirm the value. K-factor :8000 Odometer reading - Press ENTER and key in the required new odometer reading. Bear in mind that the last digit entered is the tenths digit, thus a required reading of 100.0km should be entered as 1000. Odometer : 21 055 406.0 Current time - Press ENTER and a cursor will flash. Key in the current time and press ENTER. Current time :10:35 Note the time should be set to UTC time. Current date - Press ENTER and a cursor will flash. Key in the current date and press ENTER. Current date :19/10/2003 Note the time should be set to UTC time. Time offset - Press ENTER and use the up/down arrow keys to choose a time offset between +23:00 and –23:00 hours and +59 and –59 minutes. Time offset :+1: +00 O/P shaft factor – Press ENTER and a cursor will flash. Key in the required value and press ENTER. O/P shaft factor :10.000 52 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs CANBus enabled - Press ENTER and use the ← and → keys to select ON or OFF. Press ENTER to confirm the selection. CANBus enabled Speedo OP factor - Press ENTER and a cursor will flash. Speedo OP factor :4971 :On Key in the required value and press ENTER. D6 pin function - Press ENTER and use the ← and → keys to select OFF, Revs warning or Speedometer. D6 pin function :OFF VIN - Press ENTER and type the Vehicle Identification Number. VIN :1234567890ABCDEFG This can be up to 17 characters long. Press ENTER to confirm the selection. Service delay – Read Only. Service delay :104 weeks Install date - Press ENTER and a cursor will flash. Key in the date of installation of the tachograph and press ENTER. Install date :19/09/2001 Reset Heartbeat - Press ENTER and use the ← and → keys to select ON or OFF. Press ENTER to confirm the selection. Reset Heartbeat :Off ←→ Note: when set to ON the vehicle cluster presence is confirmed by the tachograph. D4 pin function - Press ENTER and use the ← and → keys to select DTC Warning, Chart Change, Dynafleet, Low speed, Functions or Off. D4 pin function ←→ Low Speed Limit - Press ENTER and a cursor will flash. Key in the Low Speed Limit value. Low Speed Limit km/h L-Factor – Press ENTER and a cursor will flash. Key in the L-Factor value. L-Factor :1234 mm Tyre Size - Press ENTER and type the Tyre Size. This can be up to 15 characters long. Press ENTER to confirm the selection. Tyre Size :1234567890ABCDE Next Calib Date - Press ENTER and a cursor will flash. Next Calib Date :19/10/2005 :Off :5 Key in the next calibration date and press ENTER. 53 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Vehicle Registration Nation - Press ENTER and type the Vehicle Registration Nation. This can be up to 3 characters long. Press ENTER to confirm the selection. The Vehicle Registration Nation can also be referred to as Registering Member State. Veh. Reg. Nation :123 VRN - Press ENTER and type the VRN. This can be up to 13 characters long. Press ENTER to confirm the selection. VRN :1234567890ABC Speed Authorised - Press ENTER and a cursor will flash. Speed Authorised :125 km/h Key in the Speed authorised value. Illumination Input - Press ENTER and use the ← and → keys to select one of the following options. OFF, CAN ONLY, A2 ONLY. Illum. Input :OFF Revs Input C3/CAN - Press ENTER and use the ← and → keys to choose between the following options. CAN ENABLED, C3 ENABLED. Revs Inp. C3/CAN :CAN ENABLED Preferred Language - Press ENTER and the cursor will flash. Enter the correct code for the required language and press ENTER to accept it. Pref. Language :en CANBus type - Press ENTER and type the CANbus type. This can be up to 2 digits long. Press ENTER to confirm the selection. CANBus type D7 pin function - Press ENTER and use the ← and → keys to select DISABLE or ENABLE. D7 pin function :DISABLE Serial Data Out - Press ENTER and use the ← and → keys to select one of the following options. DISABLE, ENABLE SRE, ENABLE 2400. Serial Data Out :ENABLE SRE Backlight Select - Press ENTER and use the ← and → keys to select one of the following options. Colour 1, Colour 2, No Colour. Backlight Select :Colour 1 Illumination Lvl - Press ENTER and type the Illumination Lvl. This can be up to 3 digits long. Press ENTER to confirm the selection. Illumination Lvl :0 Illumination Off - Press ENTER and type the Illumination Off. This can be up to 3 digits Illumination Off :24 :255 54 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs long. Press ENTER to confirm the selection. RPM Factor - Press ENTER and type the RPM Factor. This can be up to 5 digits long. Press ENTER to confirm the selection. RPM Factor :12 CAN Termination - Press ENTER and use the ← and → keys to select DISABLE or ENABLE. CAN Termination :ENABLE Add. Event Rec. - Press ENTER and use the ← and → keys to select DISABLE or ENABLE. Add. Event Rec. :ENABLE Eng. Speed Rec. - Press ENTER and use the ← and → keys to select DISABLE or ENABLE. Eng. Speed Rec. :ENABLE VRESD (Vu Ranges Engine Speed Data) Press ENTER and type the VRESD. This can be up to 7 digits long. Press ENTER to confirm the selection. VRESD :Rng1= 7999.875 Veh. Speed Rec. - Press ENTER and use the ← and → keys to select DISABLE or ENABLE. Veh. Speed Rec. :ENABLE VRVSD (Vu Ranges Vehicle Speed Data) Press ENTER and type the VRVSD. This can be up to 3 digits long. Press ENTER to confirm the selection. VRVSD :Rng1= 111 D5 pin function - Press ENTER and use the ← and → keys to select DISABLE or ENABLE. D5 pin function CAN trip reset - Press ENTER and use the ← and → keys to select ISO or MAN. CAN trip reset :MAN Pre-Overspeed - Press ENTER and type the Pre-Overspeed. This can be up to 2 digits long. Press ENTER to confirm the selection. Pre-Overspeed :6 Once done a new screen will appear requesting the input for TCO1 WARNING?, use the ← and → keys to select DISABLE or ENABLE. Pre-NextCalib - Press ENTER and type the Pre-NextCalib. This can be up to 3 digits long. Press ENTER to confirm the selection. :DISABLE TCO1 WARNING? :ENABLE Pre-NextCalib :111 55 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Display Function - Press ENTER and use the ← and → keys to select DISABLE or ENABLE. Display Function :ENABLE Max.Warranty – This parameter is READ ONLY. Max. Warranty MONTHS War.Valid Time - This parameter is READ ONLY. War.Valid Time :00/00/0000 Warranty Time - Press ENTER and type the Warranty Time. This can be up to 2 digits long. Press ENTER to confirm the selection. Warranty Time :30 MONTHS No. writes WT - This parameter is READ ONLY. No. writes WT Activation Time - This parameter is READ ONLY. Activation Time :UNACTIVATED W-Factor - Press ENTER and a cursor will flash. Key in the W-Factor value. W-Factor :8000 Having entered the values to be programmed into the tachograph, return to the MAIN MENU by pressing Menu button and now select SEND ALL DATA (shortcut key 9) by pressing the arrow keys. SE5000 MAIN MENU :SEND ALL DATA As instructed on the display, press ENTER to send the data. On completion of the data transfer the Programmer will indicate Data Transfer OK. Sending Data Data Transfer OK In the event of a problem, the message Transfer FAILURE will be displayed. In that event check the harness connection. Transfer FAILURE :36 :0 56 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs 5.7 Programming DTCO Series tachographs Parameters which may be programmed • K-Factor • Time Offset • Tyre Size • Odometer • Output shaft factor • Next Calibration Date • Current time • VIN • Vehicle Reg. Nation • Current date • L-Factor • W-Factor • Pulses Per Rev • Speed Authorised • Install Date • CANBus type • VRN Connections Table 13: DTCO Programming connections Tachograph Harness Connection DTCO Series Z DIN plug to socket C on Programmer and D-shaped connector to socket on front of tachograph. Procedure Select READ ALL DATA from the main menu and press ENTER. DTCO MAIN MENU :READ ALL DATA Select MODIFY DATA from the main menu and press ENTER. DTCO MAIN MENU :MODIFY DATA Use the ← and → to select the parameter you wish to alter. K-factor - Press ENTER and type in the new value. Press enter again to confirm the value. K-factor :8000 Odometer reading - Press ENTER and key in the required new odometer reading. Odometer : 21 055 406.0 Bear in mind that the last digit entered is the tenths digit, thus a required reading of 100.0km should be entered as 1000. Current time - Press ENTER and a cursor will Current time 57 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs flash. Key in the current time and press ENTER. :10:35 Note the time should be set to UTC time. Current date - Press ENTER and a cursor will flash. Key in the current date and press ENTER. Current date :19/10/2003 Note the time should be set to UTC time. Time offset - Press ENTER and use the up/down arrow keys to choose a time offset between +23:00 and –23:00 hours and +59 and –59 minutes. Time offset :+1: +00 Output shaft factor - It is not necessary to change this value. O/P shaft factor :8.140 VIN - Press ENTER and type the Vehicle Identification Number. This can be up to 17 characters long. Press ENTER to confirm the selection. VIN :1234567890ABCDEFG L-Factor – Press ENTER and a cursor will flash. Key in the L-Factor value. L-Factor :1234 mm Tyre Size - Press ENTER and type the Tyre Size. This can be up to 15 characters long. Press ENTER to confirm the selection. Tyre Size :1234567890ABCDE Next Calib Date - Press ENTER and a cursor will flash. Key in the next calibration date and press ENTER. Next Calib Date :19/10/2005 Vehicle Registration Nation - Press ENTER and type the Vehicle Registration Nation. This can be up to 3 characters long. Press ENTER to confirm the selection. The Vehicle Registration Nation can also be referred to as Registering Member State. Veh. Reg. Nation :123 VRN - Press ENTER and type the VRN. This can be up to 13 characters long. Press ENTER to confirm the selection. VRN :1234567890ABC Speed Authorised - Press ENTER and a cursor will flash. Key in the Speed authorised value. Speed Authorised :125 km/h CANBus type - Press ENTER and type the CANbus type. This can be up to 2 digits long. Press ENTER to confirm the selection. CANBus type W-Factor - Press ENTER and a cursor will W-Factor :24 58 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs flash. Key in the W-Factor value. :8000 Install date - Press ENTER and a cursor will flash. Key in the date of installation of the tachograph and press ENTER. Install date :19/09/2001 Pulses per Rev - Press ENTER and a curser will flash. Enter the number required and press ENTER again to accept. Pulses per Rev :4.000 CANBus Type - Press the ENTER key. This will cause a flashing cursor to appear. Enter the required number(0 – 99), and press ENTER to confirm. CANBus type :01 Having entered the values to be programmed into the tachograph, return to the MAIN MENU by pressing Menu button and now select SEND ALL DATA (shortcut key 9) by pressing the arrow keys. DTCO MAIN MENU :SEND ALL DATA As instructed on the display, press ENTER to send the data. On completion of the data transfer the Programmer will indicate Data Transfer OK. Sending Data Data Transfer OK In the event of a problem, the message Transfer FAILURE will be displayed. In that event check the harness connection. Transfer FAILURE 59 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs 5.8 Programming Smartach Series tachographs Parameters which may be programmed • VIN • Current time • Current date • Time Offset • Odometer • K-factor • L-factor • W-factor • Tyre Size • Next Calibration date • Speed Authorised • Vehicle Reg. Nation • VRN Connections Table 13: Smartach Programming connections Tachograph Harness Connection Smartach Series Z DIN plug to socket C on Programmer and D-shaped connector to socket on front of tachograph. Procedure Select READ ALL DATA from the main menu and press ENTER. S.TACH MAIN MENU :READ ALL DATA Select MODIFY DATA from the main menu and press ENTER. S.TACH MAIN MENU :MODIFY DATA Use the ← and → to select the parameter you wish to alter. K-factor - Press ENTER and type in the new value. Press enter again to confirm the value. K-factor :8000 Odometer reading - Press ENTER and key in the required new odometer reading. Odometer : 21 055 406.0 Bear in mind that the last digit entered is the tenths digit, thus a required reading of 100.0km should be entered as 1000. 60 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Current time - Press ENTER and a cursor will flash. Key in the current time and press ENTER. Current time :10:35 Note the time should be set to UTC time. Current date - Press ENTER and a cursor will flash. Key in the current date and press ENTER. Current date :19/10/2003 Note the time should be set to UTC time. Time offset - Press ENTER and use the up/down arrow keys to choose a time offset between +23:00 and –23:00 hours and +59 and –59 minutes. Time offset :+1: +00 VIN - Press ENTER and type the Vehicle Identification Number. VIN :1234567890ABCDEFG This can be up to 17 characters long. Press ENTER to confirm the selection. L-Factor – Press ENTER and a cursor will flash. Key in the L-Factor value. L-Factor :1234 mm Tyre Size - Press ENTER and type the Tyre Size. Tyre Size :1234567890ABCDE This can be up to 15 characters long. Press ENTER to confirm the selection. Next Calib Date - Press ENTER and a cursor will flash. Key in the next calibration date and press ENTER. Next Calib Date :19/10/2005 Vehicle Registration Nation - Press ENTER and type the Vehicle Registration Nation. This can be up to 3 characters long. Veh. Reg. Nation :123 Press ENTER to confirm the selection. The Vehicle Registration Nation can also be referred to as Registering Member State. VRN - Press ENTER and type the VRN. This can be up to 13 characters long. Press ENTER to confirm the selection. VRN :1234567890ABC Speed Authorised - Press ENTER and a cursor will flash. Key in the Speed authorised value. Speed Authorised :125 km/h W-Factor - Press ENTER and a cursor will flash. Key in the W-Factor value. W-Factor :8000 61 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Having entered the values to be programmed into the tachograph, return to the MAIN MENU by pressing Menu button and now select SEND ALL DATA (shortcut key 9) by pressing the arrow keys. S.TACH MAIN MENU :SEND ALL DATA As instructed on the display, press ENTER to send the data. On completion of the data transfer the Programmer will indicate Data Transfer OK. Sending Data Data Transfer OK In the event of a problem, the message Transfer FAILURE will be displayed. In that event check the harness connection. Transfer FAILURE 62 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs 5.8 Reading of speed pulses from the front of Kienzle 1314, 1318 and 1319 When using a Tachograph Programmer with 1314, 1318 and 1319 tachographs, a minor inconsistency occurs when using the front sockets. This has some effect when carrying out either the K-Factor test, Bench test or the Speed simulator test using a jack plug. The signal coming through the sender cable is a square waveform and therefore oscillates between two states ‘high’ and ‘low’, If, at the time of performing a Bench test, the sender signal is in its low state, then this ‘grounds’ the circuitry in the tachograph and gives the appearance that the tachograph is inactive. There are two ways in which this can be overcome. Either disconnect the sender or move the vehicle slightly forward. The table below recommends which method to apply with which test: Table 14: Kienzle 1314,1318, 1319 Speed Pulse Method Bench Test K-Factor Test Speed Test Disconnect Sender Yes Yes No *Move Vehicle slightly forward No Yes Yes • When carrying out either the K-factor test or the Speed test with the tachograph still mounted in the cab of the vehicle, the more practical solution would be to roll the vehicle slightly forward (until the tachograph speed pointer moves up to the correct speed being sent by the Programmer), then stop the vehicle. 63 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs ANNEX A - TEST HARNESSES FOR USE WITH THE TACHOGRAPH PROGRAMMER Part Number Harness Diagrams Application Yellow (C) 7780-981 Socket A of Programmer Tachograph Drive Lead 6 pin DIN plug To Socket B Tachograph Yellow Socket A of Programmer Vehicle Sender Connection Lead (D) 7780-982 6 pin DIN plug Red To Socket C Tachograph (E) PPR/Engine rev Calibration Lead Red 7780-983 5 pin DIN plug “W” terminal Alternator Brown (F) 7780-986 To Socket D Tachograp h 4 mm Socket Serial Data Out Adapter Lead Black - 0 volts (G) Socket A of programmer Jack Socket Connection Lead 7780-984 Jack Plug to Tachograph 5 pin DIN plug Red (H) Socket B of programmer To Serial Socket next to DIL Switches 7780-989 Serial Data Connection Lead 4 pin DIN plug Black - 0 volts 64 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Part Number (I) UK 7955-778 EURO -779 Harness Diagrams Application Socket A of programmer Battery Charger 5 pin DIN plug To Mains Supply To be pushed on Black plugs on harnesses G or H (J) 2714-377 “Crocodile Clip” White To socket Km/h MPH (L) 7780-988 White Socket A of programmer 5 pin DIN plug KZ1314 Drive Lead W factor Lead To sender “Note : 3 wire plug” Yellow Yellow MotoMeter bench test lead adapter (M) 7780-974 To Motometer pulser socket Minitimer pulser connector Socket C of programmer (N) 7780-980 (O) 8 pin DIN plug 8 pin DIN plug 4mm Jack socket 8 way connector to Tacho 7780-979 MotoMeter programming lead Kienzle 1319 K-factor lead 65 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Part Number (P) Harness Diagrams Application Connector to Tacho Socket C of programmer Kienzle 1319 programming lead 7780-973 8 pin DIN plug To D Socket (Violet) (Q) MotoMeter Revs Adapter Lead 7780-975 Jack socket White White MotoMeter Power Adapter Lead (R) 7780-976 (S) To Motometer power socket Minitimer Power connector 4mm socket 4mm Jack 7780-978 (T) 4mm socket 4mm Jack 7780-977 Flexible extension for use with harness G (KZ1318, VR8400) Flexible extension for use with harness G (KZ1314 only) 8 pin DIN plug VR2400 Calibration/ programming (U) 7780-954 6-pin D-shaped connector 66 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Part Number Harness Diagrams Application VR2400/ VR8900/ K1324/ SE5000 Canbus (V) 7780-956 To socket A on tachograph 8 pin DIN plug 1324 Calibration/ programming (W) 7780-952 D-shaped connector 8 pin DIN plug To socket D on tachograph 2400 serial data lead (X) 7780-955 4mm socket brown Digital tachograph interface cable (Z) 7945-013 8 pin DIN plug D-shaped connector Socket C of programmer 7955-938 SE Clock Adapter 8 pin DIN plug SE Clock Tester Socket A of programmer 7780-946 5 pin DIN plug Battery Discharge Device 67 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Part Number 7780-949 Harness Diagrams 6-pin female connector Application 6-pin male connector To PC Serial Port To Socket D of programmer 7780-953 RJ11 6-WAY 9-Way D-Type Socket 7955-777 To socket B on Programmer Flat Cable Assembly for Bench Test (VR2400 only) Field Download Cable Assy (Note: Used for Programmer Software Upgrades Only. See section 1.4 for more details). Flexi-switch is used with the “Fixed Distance #2” feature, providing a very simple accurate method of vehicle calibration. Please note that all of the cables listed in Annex A are supplied as part of a standard Hand-held programmer Kit EXCEPT the Flexi-Switch (7955-777) which must be purchased separately. 68 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs ANNEX B (a) DETAILS OF BENCH TEST ROUTINES UK Bench Test Before performing the Bench Test, go to the Diagnostics menu and check that the UK Bench Test is selected (see Section 2.6). At the end of the Benchtest perform the Clock Test (see section 4.7 for details). From the MAIN MENU select BENCH TEST using the ← and → keys, and press ENTER. VR2400 MAINMENU :BENCH TEST Select the Tachograph scale (125 km/h, 140 km/h, 180 km/h, 100 km/h or 160 km/h) using the ← and → keys, and press ENTER. Select the scale : 125 km/h ← → Set the tachograph to a K-factor of 8000 (remember to note the original setting first), or press delete and enter K factor required. The display and the setting method will vary according to the type of tachograph selected. Press ENTER. For a VR2400 tachograph benchtest, it is easier to read-in the K factor first and use this value in the benchtest. Select K-factor :8000 Pul/km? Select whether the change of Duty is to be automatically changed or manually changed. Auto Duty : Off <--> Press ENTER to accept current settings or the ← and → keys to change. Note: Auto Duty can only be programmed via the front connector. Perform the task displayed. Press ENTER on completion. N.B. Some VR2400 tachographs may not have a display in which case this check can be omitted. Check backlight illuminated Perform the task displayed. Press ENTER on completion. Prepare and insert chart(s) Note: For dual driver, 2 charts have to be inserted. For a single driver, only 1 chart has to be inserted. Perform the task displayed. Press ENTER on completion. Driver=Active Crew=Active The speed will now be maximum speed for the selected scale for 10 seconds, e.g. 125km/h, and the time will count down to zero and then an audible beep will be heard. Speed: 125 km/h Time: 10 s 69 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs The speed displayed will then go to 0km/h for 10 seconds (the time will count down to zero) and an audible beep will be heard again. Speed: 0 km/h Time: 10 s Note the current odometer reading on the tachograph. This will be required later to check the accuracy of the odometer. Press ENTER. Note odometer reading The speed will now go to 40km/h and will be held for 2½ minutes (150 seconds – the time will count down to zero). To move on to the next test before the end of the normal time press ENTER. At the end of the 2½ minute test there will be an audible beep. Speed: 40 km/h Time: 150 s The speed will then go up to 80 km/h. After a further 2½ minutes (the time will count down to zero) there will again be an audible beep indicating the end of that test. Speed: 80 km/h Time: 150 s The speed will move up to 100 km/h for a further 3 minutes (time will count down to zero). At the end of the time there will be a further beep and the speed will return to zero. Speed: 100 km/h Time: 180 s Perform the task displayed. Press ENTER on completion. Driver=Active Crew=Active The unit will record Active 4 duty for 2 minutes (the time will count down to zero). After that time an audible beep will be heard. Recording duty Time: 120 s Perform the task displayed. Press ENTER on completion. Driver=Passive Crew=Passive The unit will record Passive 1 duty for 2 minutes (the time will count down to zero) and then beep. Recording duty Time: 120 s Perform the task displayed. Press ENTER on completion. Driver=Rest Crew=Rest The unit will record Rest 2 for 2 minutes (the time will count down to zero) and then beep Recording duty Time: 120 s Compare the new odometer reading with that noted above - a difference of 10km is expected. Check odometer added 10 km The display will then show as opposite. Check that the time on the chart corresponds with the time indicated on the clock, then press ENTER. Check clock to chart time 70 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs (b) Remove the two chart(s) and check the trace(s) (speed, duty and distance on chart 1, duty on chart 2). Press ENTER. Check chart rec. Set K for veh. Press the ENTER or MENU key to return to the MAIN MENU. VR2400 MAINMENU :BENCH TEST French Bench Test Before performing the Bench Test, check that the French Bench Test is selected from the Diagnostics menu (see Section 2.6). The speeds registered during the test will depend on the Tachograph scale selected at Step 2. The relevant speeds for each scale, and the total distance covered, are listed below: Table 15: Speeds for French Bench Test Scale 125 km/h 140 km/h 180 km/h Step 13 125 km/h 140 km/h 180 km/h Step 20 125 km/h 140 km/h 180 km/h Step 22 40 km/h 40 km/h 40 km/h Step 23 70 km/h 80 km/h 100 km/h Step 24 100 km/h 120 km/h 160 km/h Step 29 +16.75km +19 km +24 km From the MAIN MENU select BENCH TEST using the ← and → keys, and press ENTER. VR2400 MAINMENU :BENCH TEST Select the scale of the tachograph (125 km/h, 140 km/h, 180 km/h only in France) using the ← and → keys, and press ENTER. Select scale :125 km/h ← → Set the tachograph to a K-factor of 8000, (remember to make a note of the original setting), or press delete and enter K factor required. The display and the setting method will vary according to the type of tachograph selected. Press ENTER. Set K factor :8000 Pul/km? Select whether the change of Duty is to be automatically changed or manually changed. Auto Duty : Off <--> Press ENTER to accept current settings or the ← and → keys to change. 71 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Note: Auto Duty can only be programmed via the front connector. Check the tachograph settings. Check tacho settings Press ENTER. Connect the drive lead. The precise lead required will vary according to the type of tachograph. After connection press ENTER. Connect drive lead to tacho Set the power supply to 12 or 24V to match the tachograph and turn on the supply. Press ENTER. Switch on at correct voltage For tachographs with a second hand or a clock tell-tale check that the clock is stepping. Check clock is stepping OK Perform the task displayed. Press ENTER on completion. Check bulbs are illuminated Perform the task displayed. Press ENTER on completion. Prepare and insert 2 charts Close the tachograph as appropriate for the type of tachograph and press ENTER. Close the tachograph Set both Driver 1 duty and Driver 2 duty to Rest, 2 then press ENTER. Driver=Rest Crew=Rest The speed will now be maximum speed for the selected scale for 10 seconds, e.g. 125km/h, and the time will count down to zero and then an audible beep will be heard. Speed: 125km/h Time: 10s The speed displayed will then go to 0km/h for 10 seconds (the time will count down to zero) and an audible beep will be heard again. Speed : 0km/h Time : 10s The display will then show as opposite. Check that the time on the chart corresponds with the time indicated on the clock, then press ENTER. Check clock to chart time Close the tachograph as appropriate for the type of tachograph and press ENTER. Close the tachograph Note the odometer reading. Note odometer reading 72 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Set Driver 2 to Active 4, then press ENTER. Driver=Rest Crew=Active Note the time displayed on the Tachograph clock. Record time on Tacho The speed will go to maximum and will be held for 3 minutes (180 seconds – the time will count down to zero). At the end of the 3 minute test there will be an audible beep. Speed: 125km/h Time: 180s The speed will return to 0km/h for a further 3 minutes (180 seconds – the time will count down to zero), after which there will be an audible beep. Speed: 0km/h Time: 180s The speed will increase to the value shown in Table 15. After 180 seconds (the time will count down to zero) there will again be an audible beep. Speed: 40km/h Time: 180s The speed will increase to the value shown in Table 15. After 180 seconds (the time will count down to zero) there will again be an audible beep. Speed: 70km/h Time: 180s The speed will then will increase to the value shown in Table 15. After 180 seconds (the time will count down to zero) there will again be an audible beep. Speed: 100km/h Time: 180s Set both duty knobs to the passive position (both 1), then press ENTER. Driver=Passive Crew=Passive The unit will time 180s (the time will count down to zero) of the duty, after which there will again be an audible beep Speed: 0km/h Time: 180s Set Driver 1 duty Active, 4, Driver 2 duty Rest, 2, then press ENTER. Driver=Active Crew=Rest The unit will time another 180s (the time will count down to zero) . After 180 seconds there will again be an audible beep indicating completion of the test. Speed: 0km/h Time: 180s Check that the odometer reading has increased over that noted previously, by 16.75km for 125 km/h scale, or 19km for 140km/h scale, or 24km for 180km/h scale selected. Check odometer :+16.75km 73 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Remove the two charts and check the traces (speed, duty and distance on chart 1, duty on chart 2). Press ENTER. Check chart recordings Reset the K-factor of the tachograph to the correct value for the vehicle (as noted at Step 3). Press ENTER. Set K-exact for vehicle Switch off the power and disconnect the tachograph. SWITCH OFF POWER SUPPLY Press the ENTER or MENU key to return to the MAIN MENU. (c) German Bench Test Before performing the Bench Test, check that the German Bench Test is selected in the Diagnostics menu (see section 2.6). The speeds registered during the test will depend on the Tachograph scale selected at Step 2. The relevant speeds for each scale are listed below: Table 16: Speeds for German Bench Test Scale Speeds: 1 100 km/h 170 km/h 125 km/h 170 km/h 140 km/h 170 km/h 160 km/h 170 km/h 180 km/h 170 km/h 2 180 km/h 180 km/h 180 km/h 180 km/h 180 km/h 3 0 km/h 0 km/h 0 km/h 0 km/h 0 km/h 4 90 km/h 115 km/h 130 km/h 150 km/h 170 km/h 5 100 km/h 125 km/h 140km/h 160 km/h 180 km/h 6 30 km/h 40 km/h 40 km/h 60 km/h 40 km/h 7 60 km/h 80 km/h 80 km/h 100 km/h 100 km/h 8 90 km/h 120 km/h 120 km/h 140 km/h 160 km/h 9 100 km/h 125 km/h 140 km/h 160 km/h 180 km/h 10 90 km/h 120 km/h 120 km/h 140 km/h 160 km/h 11 60 km/h 80 km/h 80 km/h 100 km/h 100 km/h 12 30 km/h 40 km/h 40 km/h 60 km/h 40 km/h 13 30 km/h 40 km/h 40 km/h 60 km/h 40 km/h 14 60 km/h 80 km/h 80 km/h 100 km/h 100 km/h 15 80 km/h 110 km/h 110 km/h 110 km/h 150 km/h 16 90 km/h 120 km/h 120 km/h 140 km/h 160 km/h 17 90 km/h 115 km/h 130 km/h 150 km/h 170 km/h 18 100 km/h 125 km/h 140 km/h 160 km/h 180 km/h 19 90 km/h 120 km/h 120 km/h 140 km/h 160 km/h 20 60 km/h 80 km/h 80 km/h 100 km/h 100 km/h 21 30 km/h 40 km/h 40 km/h 60 km/h 40 km/h 74 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs From the MAIN MENU select BENCH TEST using the ← and → keys, and press ENTER. VR2400 MAINMENU :BENCH TEST Select the Tachograph scale (125 km/h, 140 km/h, 180 km/h, 100 km/h or 160 km/h). Select the scale : 125 km/h ← → Set the tachograph to a K-factor of 8000 (remember to note the original setting first), or press delete and enter K factor required. The display and the setting method will vary according to the type of tachograph selected. Press ENTER. Select K-factor :8000 Pul/km? Select whether the change of Duty is to be automatically changed or manually changed. Auto Duty : Off <--> Press ENTER to accept current settings or the ← and → keys to change. Note: Auto Duty can only be programmed via the front connector. Perform the task displayed. Press ENTER on completion. Check tacho settings Connect the drive lead. The precise lead required will vary according to the type of tachograph. After connection press ENTER. Connect drive lead to tacho Set the power supply to 12 or 24V to match the tachograph and turn on the supply. Press ENTER. Switch on at correct voltage For tachographs with a second hand or a clock tell-tale check that the clock is stepping. Press ENTER on completion. Check clock is stepping OK Perform the task displayed. Press ENTER on completion. Check bulbs are illuminated The Programmer provides a specific clock check facility incorporating a clock tester for the VR2400, K1324 and MotoMeter EGK-100 tachographs. The clock test should be carried out at the end of the benchtest for these tachographs. # Check clock for accuracy 75 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs For other tachographs a separate clock tester will be required. Press ENTER to confirm that the accuracy has been tested, or exit the Benchtest (Press MENU) to perform the clock test procedure. Perform the task displayed. Press ENTER on completion. Prepare and insert 2 charts Close the tachograph as appropriate for the type of tachograph and press ENTER. Close the tachograph The speed will now be 170 km/h (speed ‘1’ in Table 16) for 5 seconds, the time will count down to zero and then an audible beep will be heard. Speed : 170 km/h Time : 5 s The speed will now increase to 180 km/h (speed ‘2’ in Table 16) for 10 seconds, the time will count down to zero and then an audible beep will be heard. Speed : 180 km/h Time : 10 s The speed will drop to 0 km/h (Speed ‘3’ in Table 16). An audible beep will be heard after 10 seconds (the time will count down to zero). Speed : 0 km/h Time : 10 s Check that the time on the chart corresponds with the time indicated on the clock, then press ENTER on completion. Check clock to chart time Move the chart on 3 minutes by advancing the clock. Press ENTER. For the VR2400, K1319 & K1324 the clock cannot be advanced manually, and the instruction is WAIT for the time to count down to zero. Advance chart Time: 180 s Close the tachograph as appropriate for the type of tachograph and press ENTER. (Note: This screen does not appear for the K1319). Close the tachograph The speed will now be speed ‘4’ (as shown in Table 16) for 5 seconds, the time will count down to zero and then a beep will be heard. Speed : 115 km/h Time : 5 s The speed will now go to the maximum for the selected scale (speed ‘5’ as shown in Table 16) and will be held for 120 seconds (the time will count down to zero). Speed: 125 km/h Time: 120 s To move on to the next test before the end of the normal time press ENTER. At the end of the 2 minute test there will be an audible beep. 76 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Open the tachograph and move the chart on 3 minutes by advancing the clock. Close the tachograph again and press ENTER. Advance chart Time: 180 s If no keys are pressed the time count down to zero and then move on to the next stage automatically. The speed will then go to the speed shown in Table 16 (speed ‘6’). After 15 seconds (the time will count down to zero) there will be an audible beep. Speed: 40 km/h Time: 15 s The speed will then go up to the speed shown in Table 16 (speed ‘7’). After 15 seconds (the time will count down to zero) there will again be an audible beep. Speed: 80 km/h Time: 15 s The speed will then go up to the speed shown in Table 16 (speed ‘8’). After 15 seconds (the time will count down to zero) there will again be an audible beep. Speed: 120 km/h Time: 15 s The speed will then go up to maximum (speed ‘9’ as shown in Table 16). After 5 seconds (the time will count down to zero) there will again be an audible beep. Speed: 125 km/h Time: 5 s The speed will then go down to the speed shown in Table 16 (speed ‘10’). After 15 seconds (the time will count down to zero) there will again be an audible beep. Speed: 120 km/h Time: 15 s The speed will then go down to the speed shown in Table 16 (speed ‘11’). After 15 seconds (the time will count down to zero) there will again be an audible beep. Speed: 80 km/h Time: 15 s The speed will then go down to the speed shown in Table 16 (speed ‘12’). After 15 seconds (the time will count down to zero) there will again be an audible beep and the speed will return to 0 km/h. Speed: 40 km/h Time: 15 s Open the tachograph and move the chart on 3 minutes by advancing the clock. Close the tachograph again and press ENTER. If no keys are pressed the time count down to zero and then move on to the next stage automatically. Advance chart Time: 180 s The speed will then go up to the speed shown in Table 16 (speed ‘13’). After 5 seconds (the time will count down to zero) there will again be a beep and the speed will return to 0 km/h. Speed: 40 km/h Time: 5 s 77 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Open the tachograph and move the chart on 3 minutes by advancing the clock. Close the tachograph again and press ENTER. Advance chart Time: 180 s If no keys are pressed the time will count down to zero and then move on to the next stage automatically. The speed will then go up to the speed shown in Table 16 (speed ‘14’). After 10 seconds (the time will count down to zero) there will again be a beep and the speed will return to 0 km/h. Speed: 80 km/h Time: 10 s Open the tachograph and move the chart on 3 minutes by advancing the clock. Close the tachograph again and press ENTER. Advance chart Time: 180 s If no keys are pressed the time will count down to zero and then go to the next stage automatically. The speed will then go up to the speed shown in Table 16 (speed ‘15’). After 10 seconds (the time will count down to zero) there will again be a beep and the speed will return to 0 km/h. Speed: 110 km/h Time: 5 s The speed will then go up to the speed shown in Table 16 (speed ‘16’). After 10 seconds (the time will count down to zero) there will again be a beep. Speed: 120 km/h Time: 10 s Open the tachograph and move the chart on 3 minutes by advancing the clock. Close the tachograph again and press ENTER. Advance chart Time: 180 s If no keys are pressed the time will count down to zero and then move on to the next stage automatically. The speed will move down to the speed shown in Table 16 (speed ‘17’) for a further 2 minutes (the time will count down to zero). At the end of the time there will be a further beep. Speed: 115 km/h Time: 5 s The speed will then go up to the maximum speed (as shown in Table 16 - speed ‘18’). After 10 seconds (the time will count down to zero) there will again be a beep. Speed: 125 km/h Time: 10 s The speed will move down to the speed shown in Table 16 (speed ‘19’) for a further 2 minutes (the time will count down to zero). At the end of this time there will be a beep. Speed: 120 km/h Time: 120 s 78 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs The speed will move down to the speed shown in Table 16 (speed ‘20’) for a further 2 minutes (the time will count down to zero). At the end of this time there will again be a beep. Speed: 80 km/h Time: 120 s The speed will move down to the speed shown in Table 16 (speed ‘21’) for a further 2 minutes (the time will count down to zero). At the end of the time there will be a further beep and the speed will return to 0 km/h. Speed: 40 km/h Time: 120 s Perform the task displayed. Press ENTER on completion. Driver=Active Crew=Active The unit will record active 4 duty time for 180 seconds, after which time a beep will be heard. Recording duty Time: 180 s Perform the task displayed. Press ENTER on completion. Driver=Passive Crew=Passive The unit will record passive 1 duty time for 180 seconds, after which time a beep will be heard. Recording duty Time: 180 s Perform the task displayed. Press ENTER on completion. Driver=Rest Crew=Rest The unit will record rest 2 for 180 seconds, after which time a beep will be heard. Recording duty Time: 180 s Remove the two charts and check the traces (speed, duty and distance on chart 1, duty on chart 2). Press ENTER. Check chart recordings Reset the K-factor of the tachograph to the correct value for the vehicle (as noted at Step 3). Press ENTER. Set K-exact for vehicle Switch off the power and disconnect the tachograph. SWITCH OFF POWER SUPPLY Press the ENTER or MENU key to return to the MAIN MENU. VR2400 MAINMENU :BENCH TEST 79 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs (d) Swedish Bench Test Before performing the Bench Test, check that the Swedish Bench Test is selected in the Diagnostics menu (see section 2.6). From the MAIN MENU select BENCH TEST using the ← and → keys, and press ENTER. VR2400 MAIN MENU :BENCH TEST Select the required Tachograph scale (i.e., 125 km/h, 140 km/h, 180 km/h or 100 km/h). Select the scale : 125 km/h ← → Set the tachograph to a K-factor of 8000 (remember to note the original setting first), or press delete and enter K factor required. The display and the setting method will vary according to the type of tachograph selected. Press ENTER. Select K factor :8000 Pul/km? Select whether the change of Duty is to be automatically changed or manually changed. Auto Duty : Off <--> Press ENTER to accept current settings or the ← and → keys to change. Note: Auto Duty can only be programmed via the front connector. Perform the task displayed. Press ENTER on completion. Check bulbs are illuminated The Programmer provides a specific clock check facility incorporating a clock tester for the VR2400, K1324 and MotoMeter EGK-100 tachographs. The clock test should be carried out at the end of the benchtest for these tachographs. For other tachographs a separate clock tester will be required. Press ENTER to confirm that the accuracy has been tested, or exit the Benchtest (Press MENU) to perform the clock test procedure. Check clock for accuracy Perform the task displayed. Press ENTER on completion. Prepare and insert 2 charts Note the current odometer reading on the tachograph. This will be required later to check the accuracy of the odometer. Press ENTER. Note odometer reading Set both duty knobs to Active 4 and press ENTER on completion. Note: when testing VR1400 tachographs the driver knob should be set to Drive. Driver=Active Crew=Active 80 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs The speed will now be maximum speed for the selected scale for 10 seconds, e.g. 125km/h, and the time will count down to zero and then an audible beep will be heard. Speed: 125 km/h Time: 10 s The speed displayed will then go to 0km/h for 10 seconds (the time will count down to zero) and an audible beep will be heard again. Speed: 0 km/h Time: 10 s Close the tachograph as appropriate for the type of tachograph and press ENTER. Close the tachograph The speed displayed will then go to 125km/h for 10 seconds (the time will count down to zero) and a beep will be heard. Speed: 125 km/h Time: 10 s The speed will then go to 50km/h for 490 seconds (the time will count down to zero) and a beep will be heard. Speed: 50 km/h Time: 490 s The speed will go up to 100 km/h for 90 seconds (the time will count down to zero) and a beep will be heard. Speed: 100 km/h Time: 90 s The speed will go up to 125km/h for 10 seconds (the time will count down to zero) and a beep will be heard. Speed: 125 km/h Time: 10 s Set both duty knobs to Rest, 2, and press ENTER on completion. Driver=Rest Crew=Rest The unit will record duty time for 120 seconds (the time will count down to zero). After that time a beep is heard. Recording duty Time: 120s Set both duty knobs to Passive, 1, and press ENTER on completion. Driver=Passive Crew=Passive The unit will record duty for 120 seconds (the time will count down to zero). After that time a beep is heard. Recording duty Time: 120s Set both duty knobs to active, 4, and press ENTER on completion. Driver=Active Crew=Active The unit will record duty time for 120 seconds (the time will count down to zero). After that time a beep is heard. Recording duty Time: 120s Look at the odometer reading and compare it to the start to check that it has increased by 10km. Check odometer added 10 km 81 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs (e) Open the tachograph, remove the charts and check the recordings are as they should be. Check chart recordings Switch off the tachograph. SWITCH OFF POWER SUPPLY Program now returns automatically to the MAIN MENU. VR2400 MAIN MENU :BENCH TEST Dutch Bench Test Before performing the Bench Test, check that the Dutch Bench Test is selected in the Diagnostics menu (see section 2.6). The speeds registered during the test will depend on the Tachograph scale selected at Step 2. The relevant speeds for each scale are listed below: Table 17: Speeds for Dutch Bench Test Scale Speeds: 1 100 km/h 90 km/h 125 km/h 120 km/h 140 km/h 120 km/h 160 km/h 140 km/h 180 km/h 160 km/h 2 0 km/h 0 km/h 0 km/h 0 km/h 0 km/h 3 0 km/h 0 km/h 0 km/h 0 km/h 0 km/h 4 30 km/h 40 km/h 40 km/h 60 km/h 40 km/h 5 60 km/h 80 km/h 80 km/h 100 km/h 100 km/h 6 90 km/h 120 km/h 120 km/h 140 km/h 160 km/h 7 100 km/h 125 km/h 140 km/h 160 km/h 180 km/h 8 90 km/h 120 km/h 120 km/h 140 km/h 160 km/h 9 60 km/h 80 km/h 80 km/h 100 km/h 100 km/h 10 30 km/h 40 km/h 40 km/h 60 km/h 140 km/h 11 90 km/h 120 km/h 120 km/h 140 km/h 160 km/h 12 0 km/h 0 km/h 0 km/h 0 km/h 0 km/h From the MAIN MENU select BENCH TEST using the ← and → keys, and press ENTER. VR2400 MAINMENU :BENCH TEST Select the Tachograph scale required (i.e., 125 km/h, 140 km/h, 180 km/h, 100 km/h or 160 km/h). Select the scale : 125 km/h ← → Set the tachograph to a K-factor of 8000 (remember to note the original setting first), or press delete and enter the K factor required. The display and the setting method will vary according to the type of tachograph selected. Press ENTER on completion. Select K-factor :8000 Pul/km? 82 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Select whether the change of Duty is to be automatically changed or manually changed. Auto Duty : Off <--> Press ENTER to accept current settings or the ← and → keys to change. Note: Auto Duty can only be programmed via the front connector. Perform the task displayed. Press ENTER on completion. Check tacho settings Connect the drive lead. The precise lead required will vary according to the type of tachograph. After connection press ENTER. Connect drive lead to tacho Set the power supply to 12 or 24V to match the tachograph and turn on the supply. Press ENTER on completion. Switch on at correct voltage Only for tachographs with a second hand or a clock tell-tale, check that the clock is stepping. Press ENTER on completion. Check clock is stepping OK Perform the task displayed. Press ENTER on completion. Check bulbs are illuminated The Programmer provides a specific clock check facility incorporating a clock tester for the VR2400, K1324 and MotoMeter EGK-100 tachographs. The clock test should be carried out at the end of the benchtest for these tachographs. For other tachographs a separate clock tester will be required. Press ENTER to confirm that the accuracy has been tested, or exit the Benchtest (Press MENU) to perform the clock test procedure. Check clock for accuracy Perform the task displayed. Press ENTER on completion. Prepare and insert 2 charts Close the tachograph as appropriate for the type of tachograph and press ENTER. Close the tachograph Set both duty knobs to Rest, 2, and press ENTER on completion. Driver=Rest Crew=Rest The speed will now be speed ‘1’ (as shown in Table 17) for 10 seconds, the time will count down to zero and then an audible beep will be heard. Speed: 120 km/h Time: 10 s The speed displayed will then go to 0km/h for 10 seconds (the time will count down to zero) and an audible beep will be heard again. Speed: 0 km/h Time: 10 s 83 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs The display will then show as opposite. Check that the time on the chart corresponds with the time indicated on the clock, then press ENTER. Check clock to chart time The speed will remain at 0 km/h for 2 minutes (120 seconds - the time will count down to zero) and then an audible beep will be heard. To move on to the next test before the end of the normal time press ENTER. Speed: 0 km/h Time: 120 s The speed will then go up to speed ‘4’ shown in Table 17. After 120 seconds (the time will count down to zero) there will again be an audible beep. To move on to the next test before the end of the normal time press ENTER. Speed: 40 km/h Time: 120 s The speed will then go up to speed ‘5’ shown in Table 17. After 120 seconds (the time will count down to zero) there will again be an audible beep. To move on to the next test before the end of the normal time press ENTER. Speed: 80 km/h Time: 120 s The speed will then go up to speed ‘6’ shown in Table 17. After 120 seconds (the time will count down to zero) there will again be an audible beep. To move on to the next test before the end of the normal time press ENTER. Speed: 120 km/h Time: 120 s The speed will then go up to speed ‘7’ shown in Table 17. After 120 seconds (the time will count down to zero) there will again be an audible beep. To move on to the next test before the end of the normal time press ENTER. Speed: 125 km/h Time: 120 s The speed will then go down to speed ‘8’ shown in Table 17. After 120 seconds (the time will count down to zero) there will again be an audible beep. To move on to the next test before the end of the normal time press ENTER. Speed: 120 km/h Time: 120 s The speed will then go down to speed ‘9’ shown in Table 17. After 120 seconds (the time will count down to zero) there will again be an audible beep. To move on to the next test before the end of the normal time press ENTER. Speed: 80 km/h Time: 120 s 84 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs The speed will then go down to speed ‘10’ shown in Table 17. After 120 seconds (the time will count down to zero) there will again be an audible beep. To move on to the next test before the end of the normal time press ENTER. Speed: 40 km/h Time: 120 s The speed will then go up to speed ‘11’ shown in Table 17. After 120 seconds (the time will count down to zero) there will again be an audible beep. To move on to the next test before the end of the normal time press ENTER. Speed: 120 km/h Time: 120 s The speed will now go to 0 km/h and will be held for 2 minutes (120 seconds - the time will count down to zero). To move on to the next test before the end of the normal time press ENTER. At the end of the 2 minute test there will be an audible beep. Speed: 0 km/h Time: 120 s Set both duty knobs to active, 4, and press ENTER on completion. Driver=Active Crew=Active The unit will record duty time for 120 seconds (the time will count down to zero). After that time a beep is heard. Recording duty Time: 120 s Remove the two charts and check the traces (speed, duty and distance on chart 1, duty on chart 2). Press ENTER. Check chart recordings Reset the K-factor of the tachograph to the correct value for the vehicle (as noted at Step 3). Press ENTER. Set K-exact for vehicle Switch off the power and disconnect the tachograph. SWITCH OFF POWER SUPPLY Press the ENTER or MENU key to return to the MAIN MENU. VR2400 MAINMENU :BENCH TEST 85 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs (f) Belgian Bench Test Before performing the Bench Test, check that the Belgian Bench Test is selected in the Diagnostics menu (see section 2.6). The maximum speed registered during the test will depend on the Tachograph scale selected at Step 2 below. From the MAIN MENU select BENCH TEST using the ← and → keys, and press ENTER. VR2400 MAINMENU :BENCH TEST Select the Tachograph scale required (i.e., 125 km/h, 140 km/h, 180 km/h, 100 km/h or 160 km/h). Select the scale : 125 km/h ← → Set the tachograph to a K-factor of 8000 (remember to note the original setting first), or press delete and enter the K factor required. The display and the setting method will vary according to the type of tachograph selected. Press ENTER on completion. Select K-factor :8000 Pul/km? Select whether the change of Duty is to be automatically changed or manually changed. Auto Duty : Off <--> Press ENTER to accept current settings or the ← and → keys to change. Note: Auto Duty can only be programmed via the front connector. Perform the task displayed. Press ENTER on completion. Check tacho settings Connect the drive lead. The precise lead required will vary according to the type of tachograph. After connection press ENTER. Connect drive lead to tacho Set the power supply to 12 or 24V to match the tachograph and turn on the supply. Press ENTER on completion. Switch on at correct voltage Only for tachographs with a second hand or a clock tell-tale, check that the clock is stepping. Press ENTER on completion. Check clock is stepping OK Perform the task displayed. Press ENTER on completion. Check bulbs are illuminated Perform the task displayed. Press ENTER on completion. Prepare and insert 2 charts Close the tachograph as appropriate for the type of tachograph and press ENTER. Close the tachograph 86 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Set both duty knobs to active, 4, and press ENTER on completion. Driver=Active Crew=Active The speed displayed will then go to 60km/h for 10 seconds (the time will count down to zero) and then an audible beep will be again. Speed: 60 km/h Time: 10 s The speed displayed will then go to 0km/h for 10 seconds (the time will count down to zero) and an audible beep will be heard again. Speed: 0 km/h Time: 10 s Open the tachograph as appropriate for the type of tachograph and press ENTER. Open the tachograph The display will then show as opposite. Check that the time on the chart corresponds with the time indicated on the clock, then press ENTER. Check clock to chart time Close the tachograph as appropriate for the type of tachograph and press ENTER. Close the tachograph Note the current odometer reading on the tachograph. This will be required later to check the accuracy of the odometer. Press ENTER. Note odometer reading Set both duty knobs to active, 4, and press ENTER on completion. Driver=Active Crew=Active Note the time displayed on the Tachograph clock. Record time on Tacho The speed ’39,0km/h’ will then be displayed on the Programmer. Press ENTER to continue. Speed39,0km/h Press <ENTER> Use the ↑ and ↓ (7 and 4) keys to increase or reduce the speed indicated by the speed pointer on the cluster until it is exactly 40km/h. Press ENTER to continue. ↑↓Pointer to 40 39,0 km/h The final speed selected will be shown and after 120 seconds (the time will count down to zero) there will be an audible beep. To move on to the next test before the end of the normal time press ENTER. Speed40,0km/h Time: 120 s The speed ’79,0km/h’ will then be displayed on the Programmer. Press ENTER to continue. Speed79,0km/h Press <ENTER> 87 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Use the ↑ and ↓ (7 and 4) keys to increase or reduce the speed indicated by the speed pointer on the cluster until it is exactly 80km/h. Press ENTER to continue. ↑↓Pointer to 80 79,0 km/h The final speed selected will be shown and after 120 seconds (the time will count down to zero) there will be an audible beep. To move on to the next test before the end of the normal time press ENTER. Speed80,0km/h Time: 120 s The maximum speed (minus 1 km/h) for the currently selected scale e.g. ‘124,0km/h’ will then be displayed on the Programmer. Press ENTER to continue. Speed124,0km/h Press <ENTER> Use the ↑ and ↓ (7 and 4) keys to increase or reduce the speed indicated by the speed pointer on the cluster until it is exactly maximum speed (e.g. 125km/h). Press ENTER to continue. ↑↓Pointer to 125 124,0 km/h The final speed selected will be shown and after 120 seconds (the time will count down to zero) there will be an audible beep. To move on to the next test before the end of the normal time press ENTER. Speed125,0km/h Time: 120 s The speed ‘101.0km/h’ will then be displayed on the Programmer. Press ENTER to continue. Speed101,0km/h Press <ENTER> Use the ↑ and ↓ (7 and 4) keys to increase or reduce the speed indicated by the speed pointer on the cluster until it is exactly 100km/h. Press ENTER to continue. ↑↓Pointer to 100 101,0 km/h The final speed selected will be shown and after 120 seconds (the time will count down to zero) there will be an audible beep. To move on to the next test before the end of the normal time press ENTER. Speed100,0km/h Time: 120 s The speed ‘61.0km/h’ will then be displayed on the Programmer. Press ENTER to continue. Speed61,0km/h Press <ENTER> Use the ↑ and ↓ (7 and 4) keys to increase or reduce the speed indicated by the speed pointer on the cluster until it is exactly 60km/h. Press ENTER to continue. ↑↓Pointer to 60 61,0 km/h 88 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs The final speed selected will be shown and after 120 seconds (the time will count down to zero) there will be an audible beep. To move on to the next test before the end of the normal time press ENTER. Speed60,0km/h Time: 120 s Set both duty knobs to active, 4, and press ENTER on completion. Driver=Active Crew=Active The unit will record duty time for 120 seconds (the time will count down to zero). After that time a beep is heard. To move on to the next test before the end of the normal time press ENTER. Active Time: 120 s Set both duty knobs to Passive, 1, and press ENTER on completion. Driver=Passive Crew=Passive The unit will record duty for 120 seconds (the time will count down to zero). After that time a beep is heard. To move on to the next test before the end of the normal time press ENTER. Passive Time: 120s Set both duty knobs to Rest, 2, and press ENTER on completion. Driver=Rest Crew=Rest The unit will record duty time for 120 seconds (the time will count down to zero). After that time a beep is heard. Rest Time: 120s Check that the odometer reading has increased over that noted previously, by the amount shown. (Note: this will vary for each scale type selected and also depending on how long it takes to adjust each speed setting up or down). Check odometer +26.705km Remove the two charts and check the traces (speed, duty and distance on chart 1, duty on chart 2). Press ENTER. Check chart recordings Press the ENTER or MENU key to return to the MAIN MENU. VR2400 MAINMENU :BENCH TEST 89 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs (g) Programming of a Custom Bench Test Custom Bench Tests may be programmed from the DIAGNOSTICS MENU. To access the Diagnostics menu, hold down the ENTER key while switching the Programmer on. To prevent unintentional use of the Diagnostic functions, a pass code will be requested. Type in 8642, and press ENTER. Enter Code :8642 Select Benchtest Type, using the arrow keys (← →) and press ENTER. DIAGNOSTICS MENU :Benchtest type Select bench-test type Custom using the arrow keys (← →) then press ENTER. Benchtest Type :Custom ← → A series of 15 screens similar to that shown opposite are then presented in turn. Each defines one stage of the speed test. To move to the definition of the next stage press →; to move to the previous stage press ←; to change the definition of that stage press ENTER. 1 Time = 250 s Speed 80 km/h Having pressed ENTER, enter the required speed for that stage of the test. If the entered speed is lower than the 10km/h, then it will automatically reset to 0km/h. Terminate the entry by pressing ENTER. Enter speed : km/h Then enter the required time for the stage (in seconds) again terminating the entry with ENTER. Thereafter press → to move on to the next stage. Setting the test time to zero will cause the unit to skip on to the next stage having a time greater than zero. Enter time : s Stages 16 to 20 allow definition of test stages where different duty modes are recorded - this must be carried out without speed since automatic tachographs would otherwise record Drive. To move to the definition of the next stage press →; to move to the previous stage press ←; to change the definition of that stage press ENTER. 16 Time= 120 s Duty=Active The Programmer will then display a screen similar to the one shown. Use the ← and → arrow keys to select the required duty mode for both Driver 1 and Driver 2 then press ENTER. Select duty : Active ← → 90 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Again enter the required test time and terminate the entry by pressing ENTER. As before enter zero time to cause that stage to be skipped. Enter time : s After stage 20 has been completed, stage 1 appears on the screen again. 1 Time = 250 s Speed 80 km/h Press the MENU key once to return to the DIAGNOSTICS MENU. DIAGNOSTICS MENU :Benchtest type On completion of the required bench test definition press MENU twice to return to the MAIN MENU. The test sequence just entered will be memorised until it is next changed and will be the selected Bench Test type. If a pre-programmed bench test type is subsequently selected the details of the entered Custom test sequence will remain in the Programmer memory. (h) Digtial Tachograph Bench Test From the MAIN MENU select BENCH TEST using the ← and → keys, and press ENTER. SE5000 MAINMENU :BENCH TEST Set the tachograph to a K-factor of 8000 (remember to note the original setting first), or press delete and enter K factor required. The display and the setting method will vary according to the type of tachograph selected. Select K-factor :8000 Pul/km? The speed will then go up to 40km/h. After 10 seconds (the time will count down to zero) there will again be an audible beep. To move on to the next test before the end of the normal time press ENTER. Speed: 40km/h Time: 10 s The speed will then go up to 80km/h. After 10 seconds (the time will count down to zero) there will again be an audible beep. To move on to the next test before the end of the normal time press ENTER. Speed: 80km/h Time: 10 s The speed will then go up to 180km/h. After 60 seconds (the time will count down to zero) there will again be an audible beep. To move on to the next test before the end of the normal time press ENTER. Speed: 180km/h Time: 60 s Set both duty knobs to Work, and press ENTER on completion. Driver=Work Crew=Work The unit will record duty time for 120 seconds (the time will count down to zero). After that time a beep is heard. Recording duty Time: 120 s 91 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs Set both duty knobs to Rest, and press ENTER on completion. Driver=Rest Crew=Rest The unit will record duty time for 120 seconds (the time will count down to zero). After that time a beep is heard. Recording duty Time: 120 s Set both duty knobs to Passive, and press ENTER on completion. Driver=Passive Crew=Passive The unit will record duty time for 120 seconds (the time will count down to zero). After that time a beep is heard. Recording duty Time: 120 s 92 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs ANNEX C DTC VR2400 SERIES TACHOGRAPH – DIAGNOSTIC TROUBLE CODES (DTC) Description Store d (Y/N) Remarks Suggested Action A00C Internal Error Y Internal device error. Reset tachograph and re-test. 9010 LCD Error Y Fascia communications. Check fascia functions (keypress, display, etc.) A400 Tachograph Power Supply Y Power interruption. Check power supply and connections. 9060 Drawer Error Y Drawer catch failure. Check drawer function. 9061 Speed Rack Error Y Speed rack motor or opto failure. Check charts inserted correctly. Reset tachograph and re-test. 9062 Duty Rack Error Y Duty rack motor or opto failure. Check charts inserted correctly. Reset tachograph and retest 9063 Cam Error Y Cam motor or opto failure. Check charts inserted correctly. Reset tachograph and retest. 9064 Chart Table Error Y Chart table motor or opto failure. Check charts inserted correctly. Reset tachograph and retest. A822 Sender-Tachograph Key/Serial Number Mismatch Y Encrypted data errors. Re-pair tachograph to Sender. Check wiring to B-socket. A423 Sender-Tachograph Communications Problem Y Encrypted communications errors (encrypted sender) or complimentary signal failure (4 wire sender) or sender disconnection. Check tachograph settings – Sender Type. Re-pair sender if necessary. Check wiring to B-socket. 9430 V-pulse Output Error Y Monitoring of V-Pulse output. Disconnect all V-pulse supported equipment. Retest tachograph. If DTC does not reappear, suspect Vpulse driven equipment. 900F Keyboard Error Y Key jammed or held for excessive period. Check all keys/buttons on tachograph. Retest tachograph. A00E Calibration Error Y Requires configuration Check tachograph settings – Install Date and Service Delay. Retest tachograph. The service delay applies to tachographs fitted with battery backed clock only – DC, Renault, MAN. A050 Driving without Chart N Speed pulses detected with drawer open, driver chart missing or chart recording complete. Ensure driver chart present and drawer properly closed. 9051 No Driver Chart Present N Drawer closed with no driver chart present. Insert driver chart 9052 No Crew Chart Present N Drawer closed with no crew chart present. Insert crew chart if required. 93 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs ANNEX D Character Map. Under certain functions, various characters can be entered by continually pressing the numeric keys on the programmer. The mapping for the characters against each key is listed below; 0!“#$%&'() 1 *+,-./:; 2ABCabc=>? 3DEFdef@[\ 4GHIghI]^_ 5 J K L j k l `{ | 6MNOmno}~ 7PQRSpqrs 8TUVtuv 9W XYZwxyz< ANNEX E - Language codes for preferred language Here is the list of the character codes for the preferred language that can be used in the MKII programmer, each code is a 2 digit character that references to a language. Code Language Code Language “en” English “it” Italian “sv” Swedish “Iv” Latvian “fr” French “It” Lithuanian “nl” Dutch “hu” Hungarian “de” German “mt” Maltese(English) “es” Spanish “pl” Polish “cs” Czech “pt” Portuguese “da” Danish “sk” Slovakian “et” Estonian “sl” Slovenian “el” Greek “fi” Finnish “ga” Irish(English) “no” Norwegian “is” Icelandic Please note that if an invalid code is entered e.g. “zk” then the language will be automatically set to English. 94 Document No. 6957-193 June 2006 Revision 2.3 ©Copyright Stoneridge Electronics Ltd Manufacturers of VEEDER-ROOT Tachographs