1. INTRODUCTION.............................................................................. 4
1.1
What does the Tachograph Programmer do?........................................................ 4
1.2
With which Tachograph Types can the Programmer be used ?............................. 4
1.3
How do I use This Manual?.................................................................................... 4
1.4
What version of Tachograph Programmer Software does this Manual Support ? .. 5
2. PREPARATION FOR USE............................................................... 6
2.1
Power Supply......................................................................................................... 6
2.1.1
Battery Charging ............................................................................................ 6
2.2
Connectors ............................................................................................................ 6
2.3
Connection Harnesses........................................................................................... 8
2.4
Functions of the Keys ............................................................................................ 8
2.5
Switching On.......................................................................................................... 8
2.6
Diagnostics Menu .................................................................................................. 9
2.6.1
Diagnostics Menu - Function Descriptions .................................................... 9
2.6.2
Diagnostics Menu - Operation of Functions.................................................. 10
2.7
Selection of tachograph type ............................................................................... 12
2.8
Selection of Pulser type (Stoneridge VR8300/1400) ............................................ 12
2.9
Selection of SENDER TYPE (Stoneridge VR2400).............................................. 13
3. PROGRAMMER FUNCTIONS ....................................................... 14
4. FUNCTION DESCRIPTIONS ......................................................... 17
4.1
Enter PIN Code.................................................................................................... 17
4.2
W-factor (Vehicle Characteristic Coefficient) Determination ................................ 17
4.2.1
Rolling Road (Hartridge or similar) ............................................................... 19
4.2.2
Fixed Distance Method No. 1 ....................................................................... 20
4.2.3
Fixed Distance Method No. 2 ....................................................................... 23
4.3
Bench Test (Connections) ................................................................................... 25
4.4
Distance Test....................................................................................................... 27
4.5
Speed Simulator .................................................................................................. 28
4.6
Revs per minute pulse test .................................................................................. 29
4.7
Clock Test............................................................................................................ 30
4.7.1
Clock Test – Motometer, Stoneridge VR2400/SE5000, Kienzle 1324/DTCO
and Actia Smartach ..................................................................................................... 30
4.7.2
Clock Test – Stoneridge VR8400/8300 Series and Kienzle 1314/1318/1319 31
4.8
Pair/Test Tacho. .................................................................................................. 32
4.9
Tacho Control ...................................................................................................... 32
2
Ltd
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics
Manufacturers of VEEDER-ROOT Tachographs
4.10 Identify Tacho – Stoneridge VR2400/SE5000 Series, Kienzle 1324/DTCO and
Actia Smartach................................................................................................................ 33
4.11 Read/Erase DTCs – Stoneridge VR2400/SE5000 Series, Kienzle 1324/DTCO and
Actia Smartach................................................................................................................ 34
4.12
K-Factor Test....................................................................................................... 35
4.13
DIL Calculate ....................................................................................................... 37
4.14
Time / Date. ......................................................................................................... 37
5. PROGRAMMING A TACHOGRAPH .............................................. 38
5.1
Programming Stoneridge VR8400 Series tachographs........................................ 38
5.2
Programming Stoneridge VR2400 Series tachographs........................................ 40
5.3
Programming Kienzle 1324 Series tachographs .................................................. 44
5.4
Programming Kienzle 1319 Series tachographs .................................................. 46
5.5
Programming MotoMeter EGK-100 tachographs ................................................ 49
5.6
Programming SE5000 Series tachographs .......................................................... 51
5.7
Programming DTCO Series tachographs ............................................................ 57
5.8
Programming Smartach Series tachographs ....................................................... 60
5.8
Reading of speed pulses from the front of Kienzle 1314, 1318 and 1319 ............ 63
ANNEX A -
TEST HARNESSES FOR USE WITH THE TACHOGRAPH PROGRAMMER .....64
ANNEX B -
DETAILS OF BENCH TEST ROUTINES................................................................69
(a)
UK Bench Test .....................................................................................................................69
(b)
French Bench Test ...............................................................................................................71
(c)
German Bench Test .............................................................................................................74
(d)
Swedish Bench Test.............................................................................................................80
(e)
Dutch Bench Test.................................................................................................................82
(f)
Belgian Bench Test...................................................................................................................86
(g)
Programming of a Custom Bench Test ................................................................................90
(h)
Digtial Tachograph Bench Test ............................................................................................91
ANNEX C -
VR2400 SERIES TACHOGRAPH – DIAGNOSTIC TROUBLE CODES (DTC) .....93
ANNEX D -
CHARACTER MAP. ................................................................................................94
ANNEX E -
LANGUAGE CODES FOR PREFERRED LANGUAGE..........................................94
3
Ltd
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics
Manufacturers of VEEDER-ROOT Tachographs
1. INTRODUCTION
1.1 What does the Tachograph Programmer do?
•
Determines the characteristic coefficient (‘W-factor’) of a vehicle using a rolling road or either of
two different fixed-distance methods;
•
Carries out bench tests of Tachographs semi-automatically;
•
Checks the K-factor setting of Tachographs;
•
Calculates the DIL switch settings for any valid K-factor;
•
Can be used as a Tachograph speed simulator;
•
Determines the appropriate pulses per engine revolution (PPR) setting for a vehicle;
•
Allows Tachograph internal parameters to be Read and Checked and Reprogrammed if required
(Note: Stoneridge VR8400/2400/SE5000 Kienzle 1319/1324/DTCO, Motometer EGK100 and Actia
Smartach tachographs only);
•
Allows the initiation self-test modes;
•
Allows the resetting of the memory to default values;
•
Can carry-out a Tachograph Clock Test;
•
Can analyse the Diagnostic Trouble Codes (DTC) stored internally in the Stoneridge
VR2400/SE5000, Kienzle 1324/DTCO and Actia Smartach Tachographs (see Annex C for a full
list of DTCs);
•
Includes internal diagnostics routines to confirm that the Programmer is functioning correctly.
1.2 With which Tachograph Types can the Programmer be used ?
The Tachograph Programmer can be used with all available types of electronic tachographs, i.e.
Stoneridge VR1400/8300/8400/2400/SE5000, Kienzle 1314/1318/1319/1324/DTCO, MotoMeter
EGK-100 and Actia Smartach.
1.3 How do I use This Manual?
This manual describes, in detail, all the functions performed by the Tachograph Programmer. The
Tachograph Programmer can be used with all electronic tachographs, many of which require
slightly different procedures.
To make it easier to find the information you require, the manual is structured as follows:
Chapter 2: PREPARATION FOR USE
Basic instructions for starting to use the Programmer, including checking and charging the battery,
and how to select the Tachograph type to be programmed.
4
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Chapter 3: MAIN MENU PROGRAMMER FUNCTIONS
Briefly describes the functions performed by the Programmer. A quick-reference Table (Table 1)
lists the functions available for each Tachograph type and the harnesses that are required for each
Programmer function.
Chapter 4: FUNCTION DESCRIPTIONS AND DETAILS OF TEST PROCEDURES
This gives a more detailed description of the different functions available in the Tachograph
Programmer and provides Step-by-step procedures for carrying out the various Tachograph tests
and functions.
Chapter 5: PROGRAMMING A TACHOGRAPH
Once the various Tachograph parameters have been determined (using the Tests described
previously), the values determined must be sent to the Tachograph so that it can be updated with
the correct parameter values.
1.4 What version of Tachograph Programmer Software does this Manual Support ?
This manual covers the Tachograph Programmer functionality for Software version Rev2.03. The
determination of the current Software Version in a Tachograph Programmer is described in
section 2.6 (Diagnostics Menu – ROM Test).
A Tachograph Programmer with an older version of Software can be upgraded to the current
version (i.e., version Rev2.03). For further information on programmer software upgrades, please
contact Stoneridge via E-mail at “sales@elc.stoneridge.com”.
A Programmer upgrade is done using a Standard PC running a dedicated installation Program
which is available on a Programmer Upgrade CD.
The PC (Serial Communications Port) is connected to the Programmer (Socket D on Figure 1) via
a Field Download Cable (Part Number: 7780-953).
5
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
2. PREPARATION FOR USE
2.1 Power Supply
The Tachograph Programmer is powered from an internal rechargeable nickel metal hydride
battery pack. The voltage of the Battery Pack may be checked at any time by selecting Battery
Detect from the Diagnostics Menu - see section 2.6 (Diagnostics Menu – Battery Detect) for
details.
The 9.6V Battery Pack has a capacity of 600mA/hr. The idle current of the programmer is
approximately 30mA, rising to a maximum of 78mA when in normal use. Standard use of the
communications features results in a current consumption of around 45mA. The OFF state current
consumption is around 35 A, which maintains the function of the Programmers internal
temperature compensated real-time clock. Based on these figures, a fully charged battery pack
should give a continuous power on time of approximately 13 hours. Assuming a badly degraded
battery, the programmer should have an expected worst case power-ON time of around 7 hours
before recharge is required.
2.1.1 Battery Charging
The battery is recharged using the AC charger supplied in the Programmer kit (illustrated as
Harness I in ANNEX A - ). When fully discharged, the battery will take approximately 14 hours to
recharge. The unit will then operate for at least 8 hours before requiring recharging. To conserve
battery charge, the unit will switch off automatically after 10 minutes of non-use (except when in a
bench test mode) or if the Voltage drops below 8V - the Critical voltage - below which tests can
become inaccurate.
The Programmer should NOT be continuously connected to the charger after an overnight
charge. This can greatly reduce the Batteries performance, and in extreme cases destroy the
Battery.
2.2 Connectors
The Tachograph Programmer has three connectors on the end of the unit above the display and
two others on the side and on the bottom, as shown on Figure 1 (see below).
A. 6-pin DIN socket for connection of battery charging unit, bench test leads, pulser leads for rolling
road or fixed distance calibration and Stoneridge VR8400 programming leads.
B. 4-pin DIN socket for connection of flexi-switch.
C. 8-pin DIN socket for connection of Stoneridge VR2400/SE5000, Kienzle 1319/ 1324/DTCO,
MotoMeter and Actia Smartach tachographs.
D. RJ11 Socket used for upgrading the Programmer Software version.
E. Smartcard Connector. Smartcards are capable of storing digital information so that the data
stored can be read by suitable electronic devices. The MKII Tachograph Programmer has a
smartcard slot which may be utilised in the future for a variety of uses including security.
6
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
FIGURE 1: MKII TACHOGRAPH PROGRAMMER OUTLINE
Socket B
Socket C
Socket A
Socket D
Socket E
7
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
2.3 Connection Harnesses
A range of different connection harnesses is supplied in the Programmer kit to allow many
different connections to tachograph systems according to the functions required. These are
illustrated and described in Annex A, and are referred to as appropriate throughout this manual.
2.4 Functions of the Keys
MENU
- Press to return to the MAIN MENU
ENTER
-
Either selects a setting to be changed or terminates an entry.
-
Cycles through the options available for a particular setting. Press either of
these keys as appropriate to move to the required function and then press
ENTER to select.
SEND
-
Sends parameter information to the attached tachograph.
DELETE
-
Allows deletion of the entered value.
0 ... 9
-
Numeric keys for entry of numeric values. They also have the secondary
function as shortcut keys (see below) and the tertiary function of inputting
letters.
-
The 1 and 4 keys have an additional function and are used to alter the speed
in a speed test.
-
Used for turning the instrument on and off. Note that if the unit is left for 10
minutes without any keys being pressed then the unit will turn off
automatically (except in bench test mode).
ON/OFF
to facilitate faster and easier use of the Programmer, the number keys also
have shortcut key functions (the shortcut keys are only active if the Tachograph
type selected supports the function). The shortcuts are as follows:
Shortcut keys-
123456789-
Rolling Road test.
Fixed Distance #1 test.
Fixed Distance #2 test.
Clock test.
R.P.M. Pulse test.
K-Factor test.
Read All Data.
Modify Data.
Send All Data.
2.5 Switching On
To switch ON the Tachograph Programmer, press the ON/OFF button on the keyboard. The unit
will first display a copyright message and the software version and then, after an audible beep, will
display the MAIN MENU. From this menu the required functions may be selected.
If the ENTER key is held down while switching ON, the Programmer will request a Pass code –
type “8642” and press “ENTER” – the Programmer will then enter the Diagnostics Menu. Please
note that the use of the Pass code is only to prevent unwanted entry to the Diagnostics Menu. The
Diagnostics functions are described in Section 2.6.
8
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
2.6 Diagnostics Menu
Within the Tachograph Programmer there are a number of additional functions provided which
carry out various self-test functions and which allow setting of various default values.
To gain access to the internal utilities, first ensure that the Tachograph Programmer is turned off.
Press and hold the ENTER key and then turn on the unit by pressing the ON key. As the unit
turns on it will emit a beep as usual, but in this case will request a Pass code – type “8642” and
press “ENTER” – the Programmer will then enter the DIAGNOSTICS MENU.
2.6.1 Diagnostics Menu - Function Descriptions
Language Select
- The MKII Tachograph Programmer may be operated in a number of
different languages. The available languages are dependant on the
Tachograph Programmer type.
Set Time and Date
-
This is used to set the time (24 hour clock) and date (ddMMyyyy format)
used by the Programmer.
Fixed Distance Length
-
This allows the Length of the Fixed Distance Track (used in Programmer
Fixed-Distance Tests) to be altered between 20 and 1000m (previously
this was fixed at 20m permanently).
Hardware Test
- This function is used in conjunction with an external test jig for
conformance testing. It is for use by SE personnel only.
Keyboard Test
- This enables the user to check that the keyboard is fully functional by
pressing each key in turn.
Display Test
-
This causes the unit to display a visual routine so that the user can check
that the display is functioning correctly.
ROM Test
-
This function can be used to check the Programmer’s internal read-only
memory (ROM) and display the result.
Battery Detect
-
This is used to check the Voltage of the Programmer’s internal battery
pack. If within tolerance, message “Battery OK!” should be displayed. If
not then the battery needs recharging.
Frequency Test
-
Used during conformance testing to calibrate the accuracy of the clock
within the Tachograph Programmer. This function is for use by SE
personnel only.
Set calib no.
-
This enables a user to enter a default identification string for a particular
tachograph fitting station. Generally this is the identification issued by the
approvals authority.
Bench test type
-
This allows the selection of the appropriate bench test for any given
country. Standard bench tests are pre-programmed for several countries;
selecting the Custom bench test option allows a user to define a different
test sequence. See Annex B for details of the Bench Tests available and
instructions for programming a custom bench test.
9
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
2.6.2
Diagnostics Menu - Operation of Functions
With the Programmer OFF, press and hold the
ENTER key and switch the device ON.
Enter PIN
:8642
To prevent unintentional use of the
Diagnostic functions, a pass code will be
requested.
Type in 8642, and press
ENTER. By pressing the ← or → keys the
required function may then be displayed.
Language Select - Press ENTER and the
current language and the characters ← → will
be displayed (on the right of display).
DIAGNOSTICS MENU
:Language Select
Press the required key (← or →) until the
required language is shown and then press
ENTER again to make the selection
permanent.
The language selected will then be used for all
the operating menus until a different language
is selected.
Press MENU once to
DIAGNOSTICS MENU.
return
to
SELECT LANGUAGE
:English
←→
the
Set time & date - Press ENTER and type in
the time in the format shown on the screen.
DIAGNOSTICS MENU
:Set time & date
Press ENTER after setting the time to set the
date in the format shown on the screen.
Time: HHmm
:09:45
When the time and date have been set, press
ENTER to confirm the settings.
Date: ddMMyyyy
:01/07/2003
Note : The time entered should be UTC time.
Fixed Dist leng – Press ENTER to display the
Fixed Distance Length.
DIAGNOSTICS MENU
:Fixed Dist leng
Press ENTER to change the distance (Note:
Range is 20 to 1000m). Enter the distance
required and press the ENTER key to accept.
Enter distance
:20
m
Press MENU to return to the Diagnostic Menu.
Hardware Test – This test is to be applied by
the manufacturer only.
DIAGNOSTICS MENU
:Hardware Test
Keyboard Test - Press ENTER and then
DIAGNOSTICS MENU
10
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
press the correct key when prompted. When
the test is successfully completed the
message: Keyboard OK! will appear briefly on
the screen.
:Keyboard Test
Display Test - Press ENTER to start the test
procedure.
DIAGNOSTICS MENU
:Display Test
The default contrast is 25% but this may be
changed using keys 1 or 4.
Adjust contrast
:25%
Press ENTER and the test runs automatically.
ROM Test - Press ENTER to start the test
procedure.
DIAGNOSTICS MENU
:ROM Test
The Checksum will appear after a brief
interval.
(c)2006 Rev 2.03
:Checksum = XXXX
Press the MENU key once to return to the
Diagnostics Menu.
Note that the actual checksum value will depend on
the version of software in the Programmer.
Battery Detect - Press ENTER to start the
test procedure.
DIAGNOSTICS MENU
:Battery Detect
The battery voltage will appear after a brief
interval.
Battery OK!
:11.239V
Press the MENU key once to return to the
Diagnostics Menu.
Frequency Test – This test is to be applied by
the manufacturer only.
DIAGNOSTICS MENU
:Frequency Test
Set calib no. - Press ENTER to view the
current calibration number.
DIAGNOSTICS MENU
:Set calib no.
Press ENTER a second time to change the
calibration number if necessary.
Set calib no.
SE 1234
Once the number has been changed, press
ENTER a third time to confirm the new values.
Press the MENU key to return to the
DIAGNOSTICS MENU.
11
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Benchtest type - Press ENTER to display the
current Benchtest type.
DIAGNOSTICS MENU
:Benchtest type
Use the ← or → keys to select UK, French,
German, Swedish, Dutch, Belgium or to
Custom the bench test procedure.
Benchtest type
:UK
←→
Press ENTER to select the required type.
2.7 Selection of tachograph type
Before using the Programmer, the model of tachograph
being calibrated must be selected from the Main Menu.
When the Programmer is switched on the first item displayed
on the MAIN MENU is TACHO SELECT. From elsewhere in
the MAIN MENU press the ← or → keys until TACHO
SELECT is displayed.
VR2400 MAIN MENU
:TACHO SELECT
Press ENTER and the TACHO TYPE menu will be displayed.
Press ENTER again and then use the ← or → keys to select TACHO TYPE
the
appropriate
tachograph
type
(Stoneridge :2400 Series
VR2400/8400/8300/1400/SE5000
series,
Kienzle
1324/1319/1318/ 1314/DTCO, Motometer EGK-100 and
Actia Smartach). Press ENTER to make the selection and then MENU to return to the MAIN
MENU.
2.8 Selection of Pulser type (Stoneridge VR8300/1400)
For Stoneridge VR8300 or VR1400 series tachographs, the
pulser type to be used must also be selected. This is to
ensure that any calibration factor determined is correct.
VR1400 MAIN MENU
:PULSER SELECT
With the Programmer at the MAIN MENU and displaying
PULSER SELECT, press ENTER and PULSER TYPE will be
displayed. Use the ← or → keys to select the appropriate
pulser type. Press ENTER to make the selection and then
MENU to return to the MAIN MENU.
PULSER TYPE
:8 Pulses/Rev ← →
Note: The 2 pulse/rev option should only be selected when the tachograph is fitted with a
Stoneridge Veeder-Root 2-pulse sender. The 8 pulse/rev option must be selected for all other
pulsers regardless of the actual number of pulses per rev from the sender.
12
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
2.9 Selection of SENDER TYPE (Stoneridge VR2400)
For Stoneridge VR2400 series tachographs, the sender type
may be selected.
VR2400 MAIN MENU
:PULSER SELECT
SENDER TYPE
: Encrypted ← →
With the Programmer at the VR2400 MAIN MENU and displaying PULSER SELECT, connect a
Cable U between the Programmers’ Socket ‘C’ and the 2400 Tachograph and then press ENTER.
Use the ← or → keys to scroll through the options until the preferred sender type is displayed.
Press ENTER and again to confirm the selection. The four choices available for sender Type are:
Encrypted, 4-Wire, 3-Wire and Magnetic.
Please note that for all other Tachograph types no sender type is selectable.
13
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
3. PROGRAMMER FUNCTIONS
This Chapter briefly describes all the MKII Programmer functions and lists the required harnesses in
Table 1. A full description of each function is included in Chapter 4.
•
Tacho Select - this function allows the operator to specify the tachograph type that is to be
calibrated or tested by the Programmer (see section 2.7 for more details).
•
Pulser Select (Stoneridge VR8300/1400 and Kienzle 1314) – this function allows the operator
to specify the pulser type (or sender type for VR2400) that is being used with the current
tachograph (see sections 2.8 and 2.9 for more details).
•
Rolling Road Test (all) - this function finds the “W” factor of the vehicle using the Hartridge (or
similar) Rolling Road (see section 4.1.1 for more details).
•
Fixed Distance #1 Test (all) - this function finds the “W” factor of the vehicle using the
Physical method 20m track (see section 4.1.2 for more details).
•
Fixed Distance #2 Test (all) - this function finds the “W” factor of the vehicle using the
Physical method 20m track with Flexi-Switch (see section 4.1.3 for more details).
•
Bench Test (all) - this semi-automatic function assists the fitter to bench test the tachograph
using a series of commands displayed on the screen (see section 4.2 for details of Bench Test
connections and Annex B for full details of all Bench Test Routines).
•
Speed Simulator Test - this function injects speed pulses into the tachograph for checking of
tachograph speed pointer, overspeed warning, or stylus positions on chart (see section 4.3 for
more details).
•
RPM Pulse Test (Stoneridge VR2400/8400/8300, Kienzle1318, Motometer EGK100, 4-stylus
tachographs only) - this function is used to find the “Pulse Per Engine Rev” from the “W”
terminal on the alternator or a revs sender (see section 4.4 for more details).
•
Clock Test - this function checks the accuracy of the tachograph clock. The function is
automatic for Motometer EGK100 tachograph, Stoneridge VR2400/SE5000, Kienzle
1324/DTCO and Actia Smartach but uses an optional external clock-tester for other
tachographs (see section 4.5 for more details).
•
Tacho Control (Stoneridge VR8400/2400 and Kienzle 1324) - this function is used to put the
tachograph into either the “Self Test” or the “Extended Test” mode, to Reset the tachograph
memory to the “Default state” or to pair a tachograph with a sender (2400/1324 only) (see
section 4.8 for more details).
•
Identify Tacho (Stoneridge VR2400/SE5000, Kienzle 1324/DTCO and Actia Smartach) – this
function interrogates the tachograph via the K-line and determines the System supplier,
Manufacture date, Serial number, Hardware version, Software number, Software version and
System name (see section 4.9 for more details).
•
Read/Erase DTCs (Stoneridge VR2400/SE5000, Kienzle 1324/DTCO and Actia Smartach) enables the Diagnostic Trouble Codes in the tachograph to be displayed on the Programmer
and then erased if required (see section 4.10 for more details).
•
Read all data/ Modify data/ Send all data (Stoneridge VR2400/SE5000, Kienzle
1319/1324/DTCO, EGK100 and Actia Smartach) - these functions interrogate the tachograph
via the K-line to allow the fitter to change the various settings on the tacho and program all the
data set-up in the Programmer in a single operation (see Chapter 5 for more details).
14
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
•
Program Tacho (Stoneridge VR8400) - this function can be used to select various settings
such as “Ignition Recording On” and “Overspeed Setting” (see section 5.1 for more details)..
•
K-factor Test (Stoneridge VR8400 and Kienzle 1319, 1318, 1314) - this function measures the
“K” factor currently set on the tachographs (see section 4.11 for more details).
•
DIL calculate (Stoneridge VR8400/8300/1400, Kienzle1318) - this function eliminates the need
to look up calibration tables (see section 4.12 for more details).
•
Time/Date (Stoneridge SE5000, Kienzle DTCO, Actia Smartach) – this function allows the
time/date, and time offset in the tachograph to be read and modified.
•
Pair/Test (Stoneride SE5000, Kienzle DTCO) – this function can be used to pair the sender,
and allow a number of tests to be carried out on the tachograph.
Table 1: Available functions and required harnesses
Tachograph
VR240
0
VR840
0
VR830
0
VR140
0
K1324
K1319
K1318
K1314
MotoMeter
EGK10
0
SE500
0
DTCO
Smartach
Rolling
Road
U or D
G+J or
D
G+J or
D
K
W or D
G+O+J
G+J or
D
G+J or
L
N
Z or D
Z or D
Z or D
Fixed Dist
#1
U or D
G+J or
D
G+J or
D
K
W or D
G+O+J
G+J or
D
G+J or
L
N
Z or D
Z or D
Z or D
Fixed Dist
#2
U or D
G+J or
D
G+J or
D
K
W or D
G+O+J
G+J or
D
G+J or
L
N
Z or D
Z or D
Z or D
Bench Test
C
G+S+J
or C
C
K
C or O
G+O+J
or C
G+S+J
or C
G+T+J
or L
C+M
or N
Z
Z
Z
Speed
Simulator
U or C
G+S+J
or C
C
K
W or C
G+O+J
or C
G+S+J
or C
G+T+J
or L
C+M
or N
Z
Z
Z
RPM Pulse
Test
E
E
E
-
W
-
E
-
N
-
-
-
Clock Test
U
Clock
Tester
Clock
Tester
-
W
Clock
Tester
Clock
Tester
Clock
Tester
N
Z
Z
Z
Tacho
Control
U
G+J
-
-
W or C
-
-
-
N
-
-
-
Identify
Tacho
U
-
-
-
W
-
-
-
-
Z
Z
Z
Read/Erase
DTCs
U
-
-
-
W
-
-
-
-
Z
Z
Z
Function
Table 1: Available functions and required harnesses (continued)
Tachograp
h
VR240
0
VR840
0
VR830
0
VR140
0
K1324
K1319
Function
K1318
K1314
MotoMeter
EGK1
00
SE500
0
DTCO
15
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Smartach
Send All
Data
U
G+J
-
-
W
P
-
-
N
Z
Z
Z
Modify
Data
U
-
-
-
W
P
-
-
N
Z
Z
Z
Read All
Data
U
-
-
-
W
P
-
-
N
Z
Z
Z
Program
Tacho
-
G+J
-
-
-
-
-
-
-
-
-
-
K-Factor
Test
-
G+J
-
-
-
G+O+
J
G+J
G+J
-
-
-
-
Pair / Test
-
-
-
-
-
-
-
-
-
Z
Z
-
Time / Date
-
-
-
-
-
-
-
-
-
Z
Z
Z
Enter PIN
-
-
-
-
-
-
-
-
-
Z
-
-
Notes:
(1) Fixed Distance #2 also requires the Flexi Switch.
(2) DIL Calculate and Tacho Select and Pulser Select do not require any connections.
16
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
4. FUNCTION DESCRIPTIONS
This chapter describes the application of the Tests available in the MKII Tachograph Programmer,
gives details of the connections required for each and provides a step-by-step instruction guide for
each function for the inexperienced user.
4.1 Enter PIN Code.
In order to read or inject pulses or to write data via the front programming connector of a digital
tachograph, the tachograph must be put into calibration mode. Calibration mode consists of a
valid workshop card being inserted into the tachograph, and a PIN code entered.
In the case of the SE5000 the PIN code can be entered either through the tachographs keypad, or
via the programmer. A PIN code function is available through the Main Menu, but the programmer
may also prompt for a PIN code if a function is attempted while the tachograph is not in calibration
mode.
Entering a PIN through the programmer operates in a similar manner to SMS messaging.
Continually pressing a key will cycle through a list of characters under that key. Pressing a new
key or waiting for approx 5 seconds, will move to the next character. Pressing Enter will ask the
tachograph to authenticate the PIN. If too many characters are entered, use the arrow and delete
keys to correct.
The list of characters under each key is detailed in Annex D
In the case of the DTCO the PIN code can only be entered through the tachograph keypad.
Insert the workshop card into the tachograph, and insert the front connector from the programmer
into the Tachograph.
From the MAIN MENU select ENTER PIN
using the ← and → keys. Press ENTER.
SE5000 MAIN MENU
:ENTER PIN
The programmer should request the code to
be entered. Enter the correct Code for the
workshop card and Press Return
Enter PIN
:
4.2 W-factor (Vehicle Characteristic Coefficient) Determination
The MKII Tachograph Programmer can use three different methods of determining the W-factor
for a vehicle, namely Rolling Road, Fixed Distance #1 and Fixed Distance #2. In each case the
W-factor (revs/km for a 2-pulse sender or pulses/km for other senders) is determined and
displayed. Where appropriate the correct setting of the tachograph DIL switches is indicated.
The choice of the method to be used will depend on the other facilities available. However, the
connections between Programmer and tachograph or sender are the same for all three of the
calibration methods used:
17
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Table 2: W-factor Test connections
Tachograph
Harness
Connection
Stoneridge VR2400
Series
U or
D
Connect to front of tachograph or directly to the
vehicle sender.
Stoneridge VR8400/
8300 Series,
G+
clip J
Jack plug of harness G to socket inside front of
Tachograph
or D only
DIN plug of harness G to Programmer socket A;
Use Crocodile clip J to make required ground
connection to a suitable point on the vehicle.
Stoneridge VR1400
Series
K
DIN plug of harness K to Programmer socket A;
connect appropriate black plug into socket on
back of tachograph;
connect other black plug directly to vehicle
sender.
Kienzle 1314
G+J or L only
As 8400 or
DIN plug of harness L to Programmer socket A;
Connect appropriate white plug into socket on
back of tachograph;
Connect other white plug directly to vehicle
sender.
Kienzle 1318
C or G+J
Jack plug of harness G to socket inside
tachograph
DIN plug of harness G to Programmer socket A;
Use Crocodile clip J to make required ground
connection to a suitable point on the vehicle.
Or DIN plug of harness C to socket A on
Programmer and other end to socket B of
tachograph.
18
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Kienzle 1319
C or G+O+J
Jack plug of harness G to socket on harness O
and 8 way connector of O to socket inside
tachograph.
DIN plug of harness G to Programmer socket A;
Use Crocodile clip J to make required ground
connection to a suitable point on the vehicle.
Or DIN plug of harness C to socket A on
Programmer and other end to socket B of
tachograph.
Kienzle1324
W
DIN plug to Programmer socket C. Other end to
D-shaped socket on front of tachograph.
MotoMeter EGK-100
N
One DIN plug of harness N to Programmer
socket A;
Other DIN plug to MotoMeter programming
socket.
SE5000/DTCO/
Smartach
Z
DIN plug to Programmer socket C. Other end to
D-shaped socket on front of tachograph.
All tachographs (Fixed
Distance #2 test)
Flexi-switch
Connect to Programmer socket B, and mount
flexi-switch on vehicle chassis.
Where a suitable connection is not available on the front of the tachograph to read pulses from the
sender, it is necessary to make a connection direct to the sender, using Harnesses D (Stoneridge
VR8300/8400/2400/SE5000 series, Kienzle 1319/1324/DTCO Series and Actia Smartach), K
(Stoneridge VR1400 series) and L (Kienzle 1314). The tachograph is bypassed completely when
using these harnesses, and a separate ground connection is not required.
4.2.1 Rolling Road (Hartridge or similar)
This method uses the Tachograph Programmer in conjunction with a rolling road. The vehicle to
be calibrated is positioned with its driving wheels on the rollers of the rolling road and is then
driven at a constant speed of 50km/h. The Tachograph Programmer will then determine the Wfactor.
19
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Procedure
Select ROLLING ROAD from the Main Menu, and follow the instructions as displayed below;
From the MAIN MENU select ROLLING
ROAD (shortcut key 1)using the ← and →
keys. Press ENTER.
VR2400 MAIN MENU
:ROLLING ROAD
Increase the speed of the vehicle as indicated
by the rolling road equipment until it is steady
at 50km/h.
Hold at 50km/h
ENTER to Start
Press ENTER and the Programmer will start
counting pulses. The pulses will be audible as
low-pitched clicks.
Hold at 50 km/h
Reading pulses
After about 15 seconds it will emit an audible
beep and the measured W-factor will be
displayed. If appropriate for the selected
tachograph type the measured K-factor and
the required DIL switch setting will be
displayed. For Stoneridge VR2400/SE5000,
Kienzle 1319/DTCO, MotoMeter EGK-100 and
Actia Smartach tachographs the required Wfactor will be retained in the Programmer (until
the Programmer is turned off) ready for later
programming of the tachograph, as described
in Chapter 5.
W=8000 K=8000
Note: In the case of the message ERROR!
CHECK CONNECTIONS being displayed,
ensure that the ground connection is made
correctly.
Otherwise check the other
connections.
ERROR! CHECK
CONNECTIONS
DIL=_23_____9_
4.2.2 Fixed Distance Method No. 1
This method typically uses the 20m measured distance often available at tachograph fitting
stations, but it is possible to set to any distance from 20 to 1000m as required. The Fixed
Distance Length can be adjusted via the Diagnostics Menu (see Section 2.6).
Care must be taken to ensure that the Fixed Distance Length set and the actual track length are
the same, otherwise the W-Factor determined will be incorrect.
The vehicle is driven along the measured track and measurements made at either end of the track
are fed into the Programmer, from which the W-factor is determined.
20
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Notes:
1. This method is only suitable for use where the pulser on the vehicle continues to produce
pulses even when the vehicle is moving very slowly.
2. It is not suitable for use with many proximity senders.
3. It is not suitable for use with 80mph scale tachographs.
4. If testing a Kienzle 1319 tachograph, ensure that the km/h scale is selected (see Section 5.4 for
details).
Procedure
A
B
20 metre track
Pointer
Distance 1
Distance 2
To use Fixed Distance Method No. 1 reliably, a method is needed of indicating accurately when
the vehicle is at the beginning and end of the measured distance. For the duration of the test some
form of pointer should be attached to the vehicle with its pointing end close to the ground. The
vehicle is driven such that the pointer passes directly over the marks at either end of the measured
distance. It is then much easier to measure the distance between each mark and the point at
which the next pulse occurs.
When attaching the pointer to the vehicle it is preferable to fix it to a point rigidly attached to the
chassis (e.g. the end of the front bumper) and not to the cab which is often sprung.
Select FIXED DISTANCE #1 from the Main Menu, and follow the instructions displayed in the
step-by-step details of the procedure that follow;
Select FIXED DISTANCE #1 on the MAIN
MENU (shortcut key 2) using the ← and →
keys, and press ENTER.
VR8400 MAIN MENU
:FIXED DIST #1
21
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Move the vehicle to the beginning of the 20m
track (position A) such that the pointer is over
the marker at the beginning of the track and
then press ENTER.
Drive to point A
Press <ENTER>
Move the vehicle slowly forward until an
audible beep is heard indicating that a pulse
has been received. Stop the vehicle and
press ENTER.
<ENTER> when new
pulse received
Measure in mm the distance just moved by
the vehicle from point A. Key this distance
into the Programmer as Distance 1 and press
ENTER to terminate the entry.
Enter Distance 1
:
mm
Move the vehicle to the end of the 20m track
(position B), again so that the pointer is over
the marker, and press ENTER. Low-pitched
clicks will be heard as the pulses are received.
<ENTER> when at
position B
Move the vehicle slowly forward again until a
louder audible beep is heard indicating that a
pulse has been received. Stop the vehicle
and press ENTER.
<ENTER> when new
pulse received
Measure in mm the distance just moved by
the vehicle from point B. Key this distance
into the Programmer as Distance 2 and press
ENTER to terminate the entry.
Enter Distance 2
:
mm
The W-factor measured for run #1 will be
displayed. Press ENTER.
End of run #1
W factor = 8005
Repeat steps 2 to 7, this time moving back
from point B to point A.
Repeat steps 2 to 7 once more in each
direction giving a total of two runs in each
direction. The measured W-factor will be
displayed at the end of each run. After keying
in the last distance and pressing ENTER, the
W-factor for the last run will be displayed.
Press ENTER again and the average of the
measured W-factors for the four runs will be
displayed, as well as the K-factor.
W=8000 K=8000
DIL=_23_____9_
The required W-factor will be retained in the Programmer (until the Programmer is turned off)
ready for later programming of the tachograph.
22
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
If appropriate for the selected tachograph type the required DIL switch setting will also be
displayed. For Stoneridge VR2400/SE5000 Series, Kienzle 1319/DTCO, MotoMeter and Actia
Smartach tachographs the required W-factor will be retained in the Programmer (until the
Programmer is turned off) ready for later programming of the tachograph.
Note: For best accuracy two runs should be carried out in each direction rather than four in
one direction since this will take account of any slight gradient of the track.
4.2.3 Fixed Distance Method No. 2
This method typically uses the 20m measured distance often available at tachograph fitting
stations, but it is possible to set to any distance from 20 to 1000m as required. The Fixed
Distance Length can be adjusted via the Diagnostics Menu (see Section 2.6).
Care must be taken to ensure that the Fixed Distance Length set and the actual track length are
the same, otherwise the W-Factor determined will be incorrect.
The vehicle is driven along the measured track but all measurements are automatically carried out
by the Programmer, which then automatically determines the W-factor.
To simplify the measurements at each end of the measured distance a flexi-switch is used which
makes contact with a marker at each end of the track. There is then no requirement for any
operator intervention - the only requirement is to drive the vehicle the length of the track at a
reasonably constant speed (roughly walking pace) such that the flexi-switch hits the markers at
either end of the track.
Note: this method is not suitable for use with 80mph scale tachographs. If testing a Kienzle 1319
tachograph, ensure that the km/h scale is selected (see Section 5.4 for details).
Benefits of Fixed Distance Method No. 2
• Easy to use. No manual intervention required.
•
Works with all types of pulser including those which stop generating pulses at low speeds.
•
Cheap to use - avoids the need to invest in a rolling road
•
Very accurate. The measurement accuracy is significantly greater than that of a rolling road. This
method can thus be used to check the accuracy of a rolling road.
A
B
20 metre track
Flexi-Switch
End-of-track Markers
23
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Procedure
Fixed Distance Method No. 2 requires the vehicle to be driven such that a flexi-switch attached to
the vehicle strikes a marker at either end of the fixed track. To maintain the measurement
accuracy the flexi switch should be attached to a part of the vehicle rigidly attached to the chassis
such as the front bumper.
Ideally the flexi-switch should be mounted with its operating lever pointing vertically downwards
and the markers should be placed on the ground. Alternatively, the flexi-switch may be mounted
with its operating level pointing horizontally to strike against vertical posts.
The markers at either end of the track are best implemented using wooden or concrete blocks,
ideally about 1m long with sides 100 to 150mm. Steel joist material is particularly suitable. The
requirement is to have a marker which will have a well defined point of contact with the flexi-switch
and which will not move during the test.
Although it is perfectly acceptable to mount the flexi-switch on the side of the vehicle with the
markers to the side of the vehicle, some difficulty may be experienced in ensuring that the switch
hits the markers repeatedly. A better arrangement is to mount the switch centrally on the front of
the vehicle and arrange the markers such that the vehicle passes directly over them.
Select FIXED DISTANCE #2 from the Main Menu, and follow the instructions displayed in the
step-by-step details of the procedure that follow;
Select FIXED DISTANCE #2 on the MAIN
MENU (shortcut key 3) using the ← and →
keys, and press ENTER.
KZ1319 MAIN MENU
:FIXED DIST #2
Move the vehicle to a position a short distance
before the beginning of the 20m track (position
A) such that the flexi-switch lever is in line with
the marker at the beginning of the track and
then press ENTER.
Drive to point A
Press <ENTER>
Drive the vehicle at a reasonably constant
speed past markers at points A and B. A low
pitched click will be heard as each pulse is
received and, at the same frequency as the
clicks, a visual indicator will be displayed as
shown. When a marker is passed a louder
audible beep will be heard.
Drive to point B
Reading pulses
After the second marker has been passed the
Programmer will display the measured Wfactor for that run. Stop the vehicle and press
ENTER.
End of run #1
W-factor = 8000
.
Drive to point B
Reading pulses
Drive to point B
Reading pulses
24
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Repeat steps 2 and 3, this time moving back
from position B to position A.
Drive to point B
Press ENTER
Repeat steps 2 and 3 once more in each
direction giving a total of two runs in each
direction. After passing the last marker the Wfactor for the last run will be displayed.
End of run #4
W-factor = 8000
Press ENTER again and the average of the
measured W-factors for the four runs will be
displayed as well as the K-Factor.
If
appropriate for the selected tachograph type
the required DIL switch setting will also be
displayed.
W=8000 K=8000
DIL=_23_____9_
Note: For best accuracy two runs should be carried out in each direction rather than four in
one direction since this will take account of any slight gradient of the track. The repeatability of
the Fixed Distance Calibration No 2 method is such that the effect of a slight gradient of the
fixed track is easily measurable. By taking the average of runs in opposite directions the effect
of the gradient is removed.
4.3 Bench Test (Connections)
Before installation and during recalibration it is necessary to carry out a bench test of the
tachograph. This requires the unit to be run at different speeds for different periods of time and
with different driver duty modes selected. The Tachograph Programmer provides a test signal
simulating the pulser output which gives the required speed outputs for the required times. The
only operator intervention is then to set the duty switches at the appropriate times as indicated by
the Programmer.
Connections
During a bench test the Programmer simulates the output from a vehicle speed/distance sender.
The harness suitable for connection to the sender input of the tachograph should therefore be
selected:
Table 3 : Bench Test connections
Tachograph
Harness
Connection
Stoneridge VR2400,
VR8300 Series
C
DIN plug to Socket A of Programmer; other end
of harness to appropriate connector on rear of
tachograph.
25
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Stoneridge VR8400
Series and Kienzle
1318 Series
C or G+S+J
As above or
Jack plug of harness G to socket of harness S
and jack plug of S to socket inside tachograph
DIN plug of harness G to Programmer socket A;
Use Crocodile clip J to make required ground
connection to a suitable point on the vehicle.
Kienzle 1319 Series
C or G+O+J
As above or
Jack plug of harness G to socket of harness O
and 8-way connector to socket on tachograph
DIN plug of harness G to Programmer socket A;
Use Crocodile clip J to make required ground
connection to a suitable point on the vehicle.
Stoneridge VR1400
Series
K
DIN plug to Socket A of Programmer; other end
of harness to appropriate connector on rear of
tachograph and to vehicle sender.
Kienzle 1314 Series
L or G+T+J
DIN plug to Socket A of Programmer; other end
of harness to appropriate connector on rear of
tachograph and to vehicle sender.
Or Jack plug of harness G to socket of harness
Tand jack plug of S to socket inside tachograph
DIN plug of harness G to Programmer socket A;
Use J to make a suitable ground connection
Kienzle1324 Series
O or C
DIN plug to socket A of Programmer; other end
of harness to appropriate connector on rear of
tachograph and to vehicle sender.
Or DIN plug to Socket A of Programmer; other
end of harness to appropriate connector on rear
of tachograph.
Motometer EGK100
C+
adapter M or
N
DIN plug of harness C to Socket A of
Programmer; other end to appropriate connector
on rear of tachograph through adapter M.
Or one end of N to socket C on Programmer and
other end to Socket on Tachograph.
SE5000/DTCO/
Smartach
Z
DIN plug to programmer socket C. Other end to
D-shaped socket on front of tachograph.
26
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Procedure
The Bench Test routines in the MKII Tachograph Programmer are designed to lead the operator
through the test without reference to other documents and wherever possible to automate the
tasks. The Bench Test is carried out with the tachograph removed from or in the vehicle.
Standard UK, French, German, Swedish, Dutch, Belgian tests, or a Custom test are available. A
Bench-Test Type can be selected via the Diagnostics Menu (see Section 2.6 for details).
Note that the bench test procedure used for the digital tachographs varies from other tachograph
types. For step-by-step details of the different Bench-test procedures see Annex B.
4.4 Distance Test
The Distance Test function is used to test the accuracy of the distance recording by injecting
pulses simulating a distance travelled of 1000m.
The distance test is specific to the SE5000, DTCO and Smartach tachographs.
Select Distance Test from the MAIN MENU
and press ENTER
SE5000 MAIN MENU
:DISTANCE TEST
At the beginning of the test the odometer
(High Resolution Total Vehicle Distance) of
the tachograph is read and stored in the
programmer.
Reading data
Find the K-factor that the tachograph is
currently set to. Press the DELETE key, and
key this value into the Programmer. Then
press ENTER.
Select K-factor
The programmer sends a message to allow
speed pulses to be output through the front of
the tachograph. If the Tachograph is already
in Calibration Mode (or if it is non-activated)
the PIN will NOT be requested.
If the
Programmer is not in Calibration mode, the
workshop card should be inserted into the
tachograph and the PIN code entered.
Sending data
Speed pulses are output to simulate 50km/h
for 72 seconds
Speed: 50 km/h
Time: 72s
At the end of the test the odometer (High
Resolution Total Vehicle Distance) of the
tachograph is read and stored in the
programmer.
Reading data
The total distance the tachograph has
recorded is then calculated, and the accuracy
displayed (to +/- 1%)
Distance = 1000m
+0%
:8000 Pul/km?
27
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
4.5 Speed Simulator
The speed simulator function is used to inject speed pulses into the tachograph. This can be used
to check the accuracy of the tachograph speed pointer or speed stylus position. The final distance
displayed also enables the tachograph odometer to be checked. When the tachograph is still fitted
in the vehicle, the speed simulator function is also useful for verifying the operation of speed or
distance related ancillaries such as the Road Speed Limiter.
Connections
These are the same as for the connections for the Bench test (see Table 3 in section 4.2).
Additionally, the pulses can be injected into the front of tachographs still fitted in the vehicle but
only if the engine is switched off (connections in this case are the same as for the K-factor Test see Table 10 in section 4.12).
Procedure
Select SPEED SIMULATOR from the Main Menu, and follow the instructions displayed in the stepby-step details of the procedure that follow;
Select SPEED SIMULATOR from the MAIN
MENU and press ENTER
VR2400 MAIN MENU
:SPEED SIMULATOR
Find the K-factor that the tachograph is
currently set to. Press the DELETE key, and
key this value into the Programmer. Then
press ENTER. Instructions for determining
the K-factor are given in section 4.12
Select K-factor
Key in the speed required and press ENTER.
Note that there is a minimum detectable
speed for each tachograph type, which
depends on the K-factor but may be up to
20km/h. Below this, the speed will reset to
0km/h.
Enter speed
The Programmer will now inject speed pulses
into the tachograph.
K=8000 Pul/km
:8000 Pul/km?
:
km/h
Speed=50 km/h
Use the ↑ and ↓ (7 and 4) keys to increase or
reduce speed.
K = 8000 Pul/km
When done press ENTER. The unit will now
display the total distance covered (in metres).
Distance=1090 m
Speed=51 km/h
Press <ENTER>
Press ENTER to key in a new speed or MENU
to return to the MAIN MENU.
VR2400 MAIN MENU
:SPEED SIMULATOR
28
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
4.6 Revs per minute pulse test
When fitting a tachograph which records engine speed (i.e. 4-stylus or EVENT tachograph) it is
necessary to determine the number of pulses received by the tachograph for each revolution of the
engine. The tachograph can then be programmed accordingly.
Connections
Table 4 : RPM Pulse Test connections
Tachograph
Harness
Connection
Stoneridge and Kienzle
4-stylus models
E
DIN plug to Socket A of Programmer; remove the
existing plug from socket C on the tachograph and
connect it to the harness socket;
(remove the grey seal for
VR8300 and VR8400
models)
Kienzle 1324 Series
Connect the red harness plug to socket C on rear
of tachograph.
W
DIN plug to socket C on Programmer.
D-shaped connector
tachograph
Motometer EGK100
G+
adapter Q
+
clip J
to
socket
on
front
of
DIN plug of harness G to Socket A of Programmer;
jack to socket D on rear of tachograph through
adapter Q. Note that the tachograph is not in the
circuit.
Use Crocodile clip J to make required ground
connection to a suitable point on the vehicle.
Procedure
Select RPM PULSE TEST from the Main Menu, and follow the instructions displayed in the stepby-step details of the procedure that follow;
From the MAIN MENU select RPM PULSE
TEST (shortcut key 5).
VR8400 MAIN MENU
:RPM PULSE TEST
Start the vehicle engine and run it at 1000
rpm.
Hold 1000 RPM
ENTER to start
Whilst holding 1000rpm press ENTER on the
Programmer. The unit will indicate Reading
pulses.
Hold 1000 RPM
Reading pulses
29
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
At the end of the test the measured PPR value
will be displayed.
End of RPM test
PPR = 8.0
Press ENTER or MENU to return to the MAIN
MENU.
VR8400 MAIN MENU
:RPM PULSE TEST
4.7 Clock Test
Most Benchtest procedures include the requirement to check the accuracy of the internal clock.
There are two different methods of determining the clock accuracy of Tachographs, and these two
methods are described as follows.
4.7.1 Clock Test – Motometer, Stoneridge VR2400/SE5000, Kienzle 1324/DTCO and Actia
Smartach
When checking one of the above tachograph types, the accuracy of the internal clock may be
checked as described in this Section. It is also very important with the 2400 to check that the chart
is in synch with the internal clock once the clock has been checked.
Connections
Table 5 : Clock Test Connections (2400, SE5000, 1324, DTCO, EGK100 and Smartach)
Tachograph
Harness
Connection
Stoneridge VR2400 Series
U
DIN plug to socket C on the Programmer and the Dshaped connector to the socket inside the front of the
tachograph
Kienzle 1324
W
DIN plug to socket C on the Programmer and the Dshaped connector to the socket on the front of the
tachograph
Motometer EGK-100
N
One end to socket C on Programmer and other end
to Socket on tachograph
SE5000/DTCO/
Smartach
Z
DIN plug to programmer socket C. Other end to Dshaped socket on front of tachograph.
Procedure
Select CLOCK TEST from the Main Menu, and follow the instructions displayed in the step-by-step
details of the procedure that follow;
30
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
4.7.2
From the MAIN MENU select CLOCK TEST
(shortcut key 4) using the ← and → keys.
Press ENTER to start the test.
EGK100 MAIN MENU
:CLOCK TEST
The Programmer will display the message
Testing clock.
Testing clock
After a few moments the clock accuracy in
seconds per day will be displayed.
Clock Accuracy
+0.2s/day
In the case of lack of signal from the
tachograph (caused by such as a faulty
connection
to
the
tachograph),
the
Programmer will display an error message.
ERROR! No signal
Press <ENTER>
Clock Test – Stoneridge VR8400/8300 Series and Kienzle 1314/1318/1319
Connections
Clock Tester to Programmer socket C. Set both duty knobs to Rest. Ensure that the tachograph is
powered and the speed pointer is at rest. Hold the adapter against the tachograph face, and move
it around until it makes a regular clicking sound - this is the correct location. Please note that the
correct location is not necessarily near the clock face, as the Tester detects the clock motor (this is
why the duty knobs must be at Rest and the pointer at zero - otherwise the Tester may detect the
chart motor instead of the clock motor). Similarly, the Tester must not be within 12 inches of a
mains transformer.
Procedure
Select CLOCK TEST from the Main Menu, and follow the instructions displayed in the step-by-step
details of the procedure that follow;
From the MAIN MENU select CLOCK TEST
(shortcut key 4) using the ← and → keys.
Hold the Tester at the correct location on the
Tachograph face (as described above). Press
ENTER to start the test.
KZ1314 MAIN MENU
:CLOCK TEST
The Programmer will display the message
Testing clock, and will make a regular clicking
sound.
Testing clock
After a short time the clock accuracy in
seconds per day will be displayed.
Clock Accuracy
+0.2s/day
In the case of loss of signal or inconsistent
signal from the tachograph (usually caused by
movement of the Tester away from the clock
motor), the Programmer will display an error
message.
ERROR! No signal
Press <ENTER>
31
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
4.8 Pair/Test Tacho.
This function allows several functions in the tachograph to be tested, such as; Display Test, LCD
negative, Printer Test, Hardware Test, Card Reader, Button Test. This function also allows the
Sender to be paired.
Select PAIR/TEST from the main menu and
press ENTER.
SE5000 MAIN MENU
:PAIR/TEST
Use the ← and → to select the test you wish
to perform, and press ENTER to start the test.
PAIR/TEST
:Display Test
Note : The tachograph has to be in calibration
mode (or non-activated). If the tachograph is
unable to perform a test for some reason, the
programmer will respond with ‘Transfer FAIL’.
The programmer will monitor the progress of
the test.
Sending Data
…
At the end of the test the ‘Data Transfer OK’
message should be displayed.
Sending Data
Data Transfer OK
4.9 Tacho Control
For the Stoneridge VR8400 series, this menu option can be used to initiate the Self Test or
Extended Test modes of the tachograph. It can also be used to reset the tachograph memory to
the default state.
For the Stoneridge VR2400, this can be used to reset the tachograph or pair the sender.
For the Kienzle 1324 Series, this can be used to pair the sender.
Connections
Table 8 : Tacho control Connections
Tachograph
Harness
Connection
Stoneridge VR2400 Series
U
8-pin DIN to socket C on the programmer and
the D-shaped connector to the socket inside
the front of the tachograph.
Stoneridge VR8400 Series
G
5-pin DIN plug to socket A on the
Programmer. Connect the jack plug to the
jack socket inside the front of the tachograph.
A ground connection is also needed to the
harness black wire. Clip J may be used to aid
connection to a suitable vehicle ground point.
Kienzle 1324
W
The 8-pin DIN plug to socket C on the
Programmer and the D-shaped connector to
the socket on the front of the tachograph
32
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Procedure
Select TACHO CONTROL from the Main Menu, and follow the instructions displayed in the stepby-step details of the procedure that follow;
Select TACHO CONTROL on the MAIN
MENU by using the ←and → keys, and press
ENTER.
VR 2400 MAIN MENU
:CONTROL MENU
From the CONTROL MENU make the
required selection - using the arrow keys
←and → to select Reset Tacho or PAIR
SENDER.
Press ENTER to send the
instruction to the tachograph.
CONTROL MENU
: Pair Sender
In the case of Reset Defaults, the programmer
will cause the tachograph to simulate a Power
Off/On Condition.
CONTROL MENU
:Reset Defaults
In the case of pair sender, press ENTER and
the sender will pair automatically within 60
seconds.
Sending data
Data transfer OK
Note: When paired to the encrypted sender,
the tachograph recognises only that sender.
The signal from the sender becomes unique to
that tachograph.
4.10
Identify Tacho – Stoneridge VR2400/SE5000 Series, Kienzle 1324/DTCO and Actia
Smartach
This function interrogates Stoneridge VR2400/SE5000, Kienzle 1324/DTCO or Actia Smartach
tachographs via the K-line. Parameters that can be determined are the System supplier,
Manufacture date, Serial number and Hardware version (all tachograph types) and Software
number, Software version and System name (all VR2400/SE5000 only).
Connections
Connect either Cable U between the Programmer and VR2400 Tachograph front connector, or
Cable W between the Programmer and the 1324 Tachograph front connector, or Cable Z between
the Programmer and the SE5000/DTCO/Smartach Tachograph front connector.
Procedure
Select IDENTIFY TACHO from the Main Menu, and follow the instructions displayed that follow;
From the VR2400 MAIN MENU use the ← and
VR2400 MAIN MENU
33
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
→ keys to select IDENTIFY TACHO.
:IDENTIFY TACHO
Press
ENTER
and
the
Programmer
interrogates the VR2400 tachograph. Use the
← and → keys to scroll through the available
options.
4.11
Read/Erase DTCs – Stoneridge VR2400/SE5000 Series, Kienzle 1324/DTCO and Actia
Smartach
This function enables the Diagnostic Trouble Codes in the tachograph to be displayed on the
Programmer and then erased from the Tachographs memory if required. For a full list of VR2400
Tachograph DTCs please see Annex C.
Connections
Table 9 : Read/Erase DTCs Connections
Tachograph
Harness
Connection
Stoneridge VR2400 Series
U
8-pin DIN to socket C on the programmer and
the D-shaped connector to the socket inside
the front of the tachograph.
Kienzle 1324
W
The 8-pin DIN plug to socket C on the
Programmer and the D-shaped connector to
the socket on the front of the tachograph
SE5000/DTCO/Smartach
Z
The 8-pin DIN plug to socket C on the
Programmer and the D-shaped connector to
the socket on the front of the tachograph
Procedure
Select Read/Erase DTCs from the Main Menu, and follow the instructions displayed in the step-bystep details of the procedure that follow;
Select READ/ERASE DTCS on the MAIN
MENU by using the ←and → keys, and press
ENTER.
VR 2400 MAIN MENU
:READ/ERASE DTCS
If no connection is made, an error Message
will be displayed, before returning to the Main
Menu.
TRANSFER FAILURE
If the connections are made, the programmer
will read the DTCs data from the Tacho and
messages will be displayed to indicate this.
Reading Data
Please Wait
34
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
(2400
and
1324
tachographs)
A typical DTC screen will then be displayed.
DTC=A423 Cnt=1
14:42 10/07/2003
Use the ↑ and ↓ (7 and 4) keys to check all
the other DTCs stored.
Press the DELETE key to delete individual
DTCs stored (Note: this function VR2400 only)
(SE5000/DTCO tachograph)
A typical DTC screen will then be displayed.
002004 Cnt=1
14:42 03/02/2005
Use the ↑ and ↓ (7 and 4) keys to check all
the other DTCs stored.
Press the DELETE key to delete individual
DTCs stored.
(Smartach tachograph)
DTC= 00200708
A typical DTC screen will then be displayed.
Use the ↑ and ↓ (7 and 4) keys to check all
the other DTCs stored.
Press the MENU key to display the message
shown.
Press <ENTER>
to clear DTCs
Press the ENTER key to delete all stored
DTCs or the MENU key to return to the Main
Menu without deleting any of the DTCs.
4.12
K-Factor Test
This provides a simple way of determining the K-factor currently set on a tachograph. The test is
applicable to Stoneridge VR8400 and Kienzle 1314, 1318 and 1319 ranges of tachograph. Note:
with VR2400, SE5000, DTCO, 1324 and Smartach tachographs the K-factor can be read directly
using Read All Data (see Section 5 for details).
Connections
Table 10 : K-factor Test Connections
Tachograph
Harness
Connection
Stoneridge VR8400
Series, Kienzle 1318
G+
clip J
Jack plug of harness G to socket inside front of
Tachograph.
DIN plug of harness G to Programmer socket A;
Use Crocodile clip J to make required ground
35
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Tachograph
Harness
Connection
connection to a suitable point on the vehicle
Kienzle 1314
G+
clip J
Jack plug of harness G to socket inside front of
Tachograph;
DIN plug of harness G to Programmer socket A;
Use Crocodile clip J to make required ground
connection to a suitable point on the vehicle
Kienzle 1319
O+
G+
clip J
4-pin rectangular connector of harness O to socket
inside front of Tachograph; other end to harness G.
The 4-pin connector will fit either way up, but only
one orientation is correct - this is indicated as a
small cross marked on the connector. When
inserting the adapter, the cross should face
upwards;
DIN plug of harness G to Programmer socket A;
Use Crocodile clip J to make required ground
connection
Procedure
Select K-FACTOR TEST from the Main Menu, and follow the instructions displayed in the step-bystep details of the procedure that follow;
From the MAIN MENU select K-FACTOR
TEST (shortcut key 6) using the ← and →
keys.
VR 8400 MAIN MENU
:K-FACTOR TEST
Press ENTER. The Programmer will first
display Sending pulses, please wait.
Sending pulses
Please wait
After a few moments the Programmer will
beep, and then display the K-factor setting of
the tachograph. If the K-factor is different
from the previous test, then the Programmer
will beep and display “<>“.
Sending pulses
K = 8000
Step 3 will then repeat until the MENU or
ENTER button is pressed. Three repetitions
are recommended.
Sending pulses
K = 8000
If a significantly different K-factor (>10
pulses/km difference) is displayed, this usually
indicates a cable fault or bad connection. It
may also be due to a faulty tachograph.
Note: In the case of the message ERROR!
CHECK CONNECTIONS being displayed,
ERROR! CHECK
36
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
ensure that the ground connection is made
correctly.
Otherwise check the other
connections.
CONNECTIONS
4.13
DIL Calculate
For the Stoneridge VR8400/8300/1400 and Kienzle 1318 tachographs the K-factor is set using a
bank of 10 DIL switches (except the VR1400, which has 8). The DIL Calculate function
determines the appropriate combination of switches for any K-factor, thus avoiding the need to use
calibration tables.
If a tachograph type has been selected which does not use DIL switches for calibration then this
menu option is not available.
Connections
No connections are required whilst calculating the appropriate DIL switch settings.
Procedure
Select DIL CALCULATE from the Main Menu, and follow the instructions displayed in the step-bystep details of the procedure that follow;
From the MAIN MENU select DIL
CALCULATE using arrow keys ← → and
press ENTER.
VR8400 MAIN MENU
:DIL CALCULATE
With the unit display as shown, press ENTER.
W=8000 K=8000
DIL = _23_____9_
The W-factor of the vehicle may then be
entered using the numeric keys; terminate the
entry by pressing ENTER again.
Enter W-factor
:
Note: W-factor determination functions are
described in section 4.1.
The exact K-factor setting will be displayed,
together with the required settings of the DIL
switches.
W=5000 K=5002
DIL = 12___6_89_
Time / Date.
This function allows the time and date to be set in the tachograph, but outside the normal
calibration procedure. This test is applicable for the SE5000, DTCO and Smartach tachographs
only.
4.14
37
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
5.
Select TIME/DATE from the main menu and
press ENTER.
SE5000 MAIN MENU
:TIME/DATE
Current time - Press ENTER and a cursor will
flash. Key in the current time and press
ENTER.
Current time
:10:35
Current date - Press ENTER and a cursor will
flash. Key in the current date and press
ENTER.
Current date
:19/10/2003
Time offset - Press ENTER and use the
up/down arrow keys to choose a time offset
between +23:00 and –23:00 hours and +59
and –59 minutes.
Time offset
:+1: +00
Press the Send key to send the data to the
tachograph.
Sending data
PROGRAMMING A TACHOGRAPH
The method of programming a tachograph varies according to the type of tachograph. For earlier
types of electronic tachograph, programming is generally carried out using internal DIL switches.
Later types require an external Programmer to set some or all of the required parameters.
Of the types requiring an external Programmer, the MKII Tachograph Programmer supports
programming of the Stoneridge VR8400/2400/SE5000 series, Kienzle 1319/1324/DTCO series,
MotoMeter EGK-100 and Actia Smartach tachographs.
Note that in all cases the instructions suggest that, once settings have been altered, the SEND
ALL DATA (shortcut key 9) command be used to transfer all the information at the end. It is,
however, possible to send each individual setting after alteration by pressing the SEND key
(except Kienzle 1319, EGK-100 and Smartach).
5.1
Programming Stoneridge VR8400 Series tachographs
Parameters which may be programmed
•
Pulses Per engine Revolution (PPR) setting
•
Ignition-on recording
•
Low power Band
•
Overspeed
•
Economy band
•
Poor Economy
Connections
Table 11: VR8400 series Programming connections
38
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Tachograph
Harness
Connection
Stoneridge
VR8400
Series
G+J
DIN plug to Programmer socket A;
Jack plug to socket inside front of tachograph
Crocodile clip to make required ground connection to a
suitable point on the vehicle, or to the negative connection of
the tachograph power supply.
Procedure for Standard and Engine Speed (RPM) Recording Versions
From the MAIN MENU select PROGRAM
TACHO and press ENTER.
VR8400 MAIN MENU
:PROGRAM TACHO
Pulses per Rev - Press ENTER and the
cursor will appear on the display. Use the
numeric keys to enter the required value. This
is usually 8 pulses per rev.
Pulses per Rev
:8
Engine Speed Recording - Select each of
the engine speed recording bands (Low
Power, Economy and Poor Economy) in turn.
Press ENTER and characters ← → will
appear. Use the ← and → keys to select the
required value and terminate by pressing
ENTER.
Low Power band
:700 Revs/min
Note: that the Programmer will not allow entry of
inconsistent engine speed bands. For example,
the user may not set a minimum speed for the
Economy band which is lower than the speed
defined for the Low Power band.
Economy band
:900 Revs/min
Poor Economy
:1100 Revs/min
Ignition On Record - Press ENTER and ←
→ will appear on the display. Use the ← or →
keys to select ON or OFF and press ENTER
to terminate the selection.
Ign On Record
:OFF
Overspeed - Press ENTER and a cursor will
flash. Key in the required overspeed value
and terminate the entry by pressing ENTER.
Overspeed
:80 km/h
Select SEND ALL DATA (shortcut key 9) from
the main menu and press ENTER.
VR8400 MAIN MENU
:SEND ALL DATA
Send All Data
When programming the tachograph, the values may be entered in turn, and then all sent to
the tachograph at once.
39
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
5.2
From the MAIN MENU select SEND ALL
DATA (shortcut key 9) and press ENTER.
VR8400 MAIN MENU
SEND ALL DATA
Press ENTER to confirm that you wish to
reprogram the tachograph, or MENU to
cancel.
Are you sure?
ENTER to program
Select the required scale type and press
Enter. Options are: 125km/h,140km/h, 80mph,
160km/h.
Select the scale
:125 km/h ← →
On completion of the data transfer the
Programmer will emit an audible beep and will
indicate Data Transfer OK.
Sending data
Data transfer OK
Programming Stoneridge VR2400 Series tachographs
Parameters which may be programmed
Please note to select the SENDER TYPE option in the VR2400 MAIN MENU select the PULSER
SELECT option (see section 2.9 for details).
•
K-factor
•
CANBus enabled
•
Pin D4 Function
•
Odometer reading
•
Customer Type
•
Low Speed Limit
•
Pulses per engine Revolution
•
Dual Axle
•
Kline Speedo
•
Engine Speed Recording
•
Dual Axle Ratio
•
Current date
•
CANBus RPM
•
Speedo OP factor
•
Time Offset
•
RPM display
•
D6 pin function
•
Output shaft factor
•
Odo leading 0s
•
Serial comms
•
4 chart trace
•
Overspeed flash
•
Ign On Record
•
Service Delay
•
DTCs enabled
•
Crew auto duty
•
Install date
•
Overspeed
•
7 day eject PIN
•
Reset Heartbeat
•
Current time
•
VIN
•
Analogue Revs
th
•
2400 Programming Connections
Table 12: 2400 series Programming connections
Tachograph
Harness
Connection
40
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
2400
U
Connect DIN plug to socket C on the Programmer and the Dshaped connector to the socket inside the front of the tachograph
Procedure
Select READ ALL DATA (shortcut key 7) from
the main menu and press ENTER.
VR2400 MAIN MENU
:READ ALL DATA
Select MODIFY DATA (shortcut key 8) from
the main menu and press ENTER.
VR2400 MAIN MENU
:MODIFY DATA
Use the ← and → to select the parameter you
wish to alter.
K-factor - Press ENTER and type in the new
value. Press enter again to confirm the value.
K-factor
:8000
Odometer reading - Press ENTER and key in
the required new odometer reading. Bear in
mind that the last digit entered is the tenths
digit, thus a required reading of 100.0km
should be entered as 1000.
Odometer
:0001235.0
Pulses Per engine Revolution - Press
ENTER and a cursor will flash. Key in the
required PPR value and press ENTER. Bear
in mind that the last three digits are
thousandths and the number 19.000 must be
typed in as 19000.
Pulses per Rev
:19.000
Engine Speed Recording - Select each of
the engine speed recording bands (Low
Power, Economy and Poor Economy) in turn.
Press ENTER and characters ← → will
appear. Use the ← and → keys to select the
required value and terminate by pressing
ENTER.
Low Power band
:700 Revs/min
Note: that the Programmer will not allow entry of
inconsistent engine speed bands. For example,
the user may not set a minimum speed for the
Economy band which is lower than the speed
defined for the Low Power band.
Economy band
:900 Revs/min
Poor Economy
:1100 Revs/min
CANBus RPM - Press ENTER and use the ←
and → keys to select ON or OFF. Press
ENTER to confirm the selection.
CANBus RPM
:Off ← →
RPM display - Press ENTER and use the ←
and → keys to select ON or OFF. Press
ENTER to confirm the selection
RPM display
:Off ← →
41
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Odo leading 0s - Press ENTER and use the
← and → keys to select ON or OFF. Press
ENTER to confirm the selection
Odo leading 0s
:Off ← →
Overspeed flash - Press ENTER and use the
← and → keys to select ON or OFF. Press
ENTER to confirm the selection
Overspeed flash
:Off ← →
DTCs enabled - Press ENTER and use the ←
and → keys to select ON or OFF. Press
ENTER to confirm the selection
DTCs enabled
:Off ← →
Overspeed - Press ENTER and a cursor will
flash. Key in the required over speed value
and press ENTER.
Overspeed
:100 km/h
Current time - Press ENTER and a cursor will
flash. Key in the current time and press
ENTER.
Current time
:10:35
The time can also be set via the keys on the
fascia of the 2400 tachograph.
Current date - Press ENTER and a cursor will
flash. Key in the current date and press
ENTER. The date can also be set via the keys
on the fascia of the 2400 tachograph.
Current date
:19/10/2000
Time offset - Press ENTER and use the
up/down arrow keys to choose a time offset
between +23:00 and –23:00 hours.
Time offset
:+1:00
Output shaft factor - It is not necessary to
change this value.
O/P shaft factor
:8.140
th
4 Chart Trace - Press ENTER and use the
← and → keys to select ON or OFF.
4th chart trace
:Off ← →
Press ENTER to confirm the selection
CANBus enabled - Press ENTER and use
the ← and → keys to select ON or OFF. Press
ENTER to confirm the selection
CANBus enabled
:Off ← →
Customer Type - Press ENTER and use the
← and → keys to select the Customer type
required. Press ENTER to confirm the
selection. Options are: ISO, Renault, Scania,
MAN, DC, Ford, VW, DAF, Volvo Bus and
Volvo AH.
Customer type
:ISO ← →
Dual axle - Press ENTER and use the the ←
and → keys to select ON or OFF. Press
ENTER to confirm the selection.
Dual axle
:Off
42
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Dual Axle Ratio - Press ENTER and type the
value of the Dual Axle Ratio required.
Dual axle ratio
:1.3750
Press ENTER to confirm the selection
Speedo OP factor - Press ENTER and a
cursor will flash.
Speedo OP factor
:4971
Key in the required value and press ENTER.
D6 pin function - Press ENTER and use the
← and → keys to select OFF, Revs warning or
Speedometer.
D6 pin function
:OFF
Serial comms - Press ENTER and use the ←
and → keys to select Standard data or
Extended data.
Serial comms
:Standard data
Ignition on Record - Press ENTER and use
the the ← and → keys to select ON or OFF.
Press ENTER to confirm the selection.
Ign On Record
:Off
←→
Crew auto duty - Press ENTER and use the
the ← and → keys to select ON or OFF. Press
ENTER to confirm the selection.
Crew auto duty
:Off
←→
7 day eject PIN - Press ENTER and type the
PIN. This must be 4 digits long. Press ENTER
to confirm the selection, (for non EU use only).
7 day eject PIN
:0000
VIN - Press ENTER and type the Vehicle
Identification Number. This can be up to 17
characters long. Press ENTER to confirm the
selection.
VIN
:1234567890ABCDEFG
Service delay - Press ENTER and a cursor
will flash. Key in the number of WEEKS left
until
compulsory recalibration
of
the
tachograph and press ENTER.
Service delay
:104 weeks
Install date - Press ENTER and a cursor will
flash. Key in the date of installation of the
tachograph and press ENTER.
Install date
:25/09/2001
Reset Heartbeat - Press ENTER and use the
← and → keys to select ON or OFF. Press
ENTER to confirm the selection.
Reset Heartbeat
:Off
←→
←→
Note: when set to ON the vehicle cluster
presence is confirmed by the tachograph.
Analogue Revs - Press ENTER and use the
← and → keys to select ON or OFF.
Analogue Revs
:On
←→
Press ENTER to confirm the selection.
43
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Pin D4 Function - Press ENTER and use the
← and → keys to select the Pin D4 function
required.
Pin D4 Function
:Off
←→
Press ENTER to confirm the selection from:
Off, Dynafleet, Low Speed, Functions, DTC
Warning and Chart Change.
Low Speed Limit - Press ENTER and a
cursor will flash. Key in the required low speed
value and press ENTER.
Low Speed Limit
:5 km/h
Kline Speedo - Press ENTER and use the ←
and → keys to select the Kline Speedo
function required. Press ENTER to confirm the
selection. Options are: Off or On.
Kline Speedo
:Off
←→
Send all data
Once the new information has been entered into the programmer, it must be sent to the
tachograph to replace the old settings.
Select SEND ALL DATA (shortcut key 9) from
the main menu and press ENTER.
5.3
VR2400 MAIN MENU
SEND ALL DATA
Programming Kienzle 1324 Series tachographs
Parameters which may be programmed
•
Odometer reading
•
Time offset
•
VIN
•
Install date
•
Output shaft factor
•
CANBus Type
•
Current time
•
W-factor
•
Service delay
•
Current date
•
K-factor
•
L-Factor
Connections
Table 13: Kienzle 1324 Programming connections
Tachograph
Harness
Connection
KZ1324 Series
W
DIN plug to socket C on Programmer and D-shaped connector to
socket on front of tachograph.
Procedure
Select READ ALL DATA (shortcut key 7) from
the main menu and press ENTER.
KZ1324 MAINMENU
:READ ALL DATA
44
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Select MODIFY DATA (shortcut key 8) from
the main menu and press ENTER.
KZ1324 MAIN MENU
:MODIFY DATA
Use the ← and → keys to select the
parameter you wish to alter.
Odometer reading - Press ENTER and key in
the required new odometer reading. Bear in
mind that the last digit entered is the tenths
digit, thus a required reading of 100.0km
should be entered as 1000.
Odometer
:100.0
Install date - Press ENTER and a cursor will
flash. Key in the date of installation of the
tachograph and press ENTER.
Install date
:19/09/2001
Current time - Press ENTER and type in the
time in the format shown. Press ENTER to
confirm
Current time:
:13:45
Current date - Press ENTER and type in the
date in the format shown. Press ENTER to
confirm
Current date
:25/09/2001
Time offset - Press ENTER and use arrow
keys to set the time offset.
Time offset
:+1:00
The range is +23 to –23 hours. Press ENTER
to confirm.
Output shaft factor - Press ENTER and type
in the required number. Bear in mind that the
last three digits are thousandths and that the
number 65.500 must be typed in as 65500.
Press ENTER to confirm.
O/P shaft factor
:65.525
W-factor - Press ENTER and type in the
number. Press ENTER to confirm.
W-factor
:8345
K-factor - This is Read Only and cannot be
modified with the MKII Programmer.
K-factor
:8000 Pul/km
VIN - Press ENTER and type the Vehicle
Identification Number. This can be up to 17
characters long.
VIN
:1234567890ABCDEFG
Press ENTER to confirm the selection.
CANBus Type - Press ENTER. Enter the 2
digit code that corresponds to the tachograph
type. 00 - OFF, 01 - 50ms, 02 -10ms or 03 20ms.
CANBus Type
:01
45
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Press ENTER to confirm the selection.
Service delay - Press ENTER and a cursor
will flash. Key in the number of WEEKS left
until
compulsory recalibration
of
the
tachograph and press ENTER.
Service delay
:104 weeks
L-Factor - Press ENTER and a cursor will
flash. Key in the circumference of the vehicle
wheel in mm and press ENTER.
L-Factor
:3000 mm
Send all data
Once the new information has been entered into the programmer, it must be sent to the
tachograph to replace the old settings.
Select SEND ALL DATA (shortcut key 9) from
the main menu and press ENTER.
5.4
KZ1324 MAINMENU
SEND ALL DATA
Programming Kienzle 1319 Series tachographs
Parameters which may be programmed
•
K-factor
•
Odometer reading
•
Over speed limit
•
Speed units (km/h or mph)
•
Calibration station Identifier
•
Calibration date
•
Installation date
•
Tachograph clock speed
Connections
Select harness P. Connect the 8-pin DIN plug to the Programmer socket C. Remove the seal and
the cover over the connector on the front of the tachograph. Connect the other end of the harness
to the pair of connectors on the front of the tachograph.
46
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Procedure
Read the current tachograph setting prior to
making changes. From the MAIN MENU
select using arrow keys READ ALL DATA
(shortcut key 7) and then press ENTER to
read data from the tachograph.
KZ1319 MAIN MENU
:READ ALL DATA
When the Programmer indicates that the data
has been received return to the MAIN MENU
and this time select MODIFY DATA (shortcut
key 8) using the ← → arrow keys. Press
ENTER.
KZ1319 MAIN MENU
:MODIFY DATA
Select the parameters to be changed. Press
the ← or → keys to move between the
parameters to be entered.
K-factor - Again press ENTER to change the
current value and enter the new value which
was stored during the W-factor measurement
(described in Section 4.1). For Kienzle 1319
tachographs, the K-factor is remembered until
the Programmer is switched off or the K-factor
is changed.
K-Factor
:52356
Odometer reading - Press ENTER and key in
the required new odometer reading. Bear in
mind that the last digit entered is the tenths
digit, thus a required reading of 100.0km
should be entered as 1000.
Odometer
:0001234.5
Over speed - Press ENTER and key in the
required new overspeed limit.
Over Speed
:100km/h
Speed Units - Press ENTER and the
characters <> will appear. Select km/h or mph
using the ← and → keys and then press
ENTER.
Speed units
:km/h
Calibration station Identifier - This is an
alphanumeric string identifying the station
carrying out the calibration.
Calib. Ident.
:SE #1234
Press ENTER and a cursor will flash indicating
which character is being changed. Press the
key with the required letter a number of times
to get the character. Use the arrow keys to
move between characters. Terminate the
entry by pressing ENTER.
Note: that a default Calib. Ident. string may be
programmed into the Programmer.
After
selecting Calib. Ident. and pressing ENTER
thus causing the cursor to flash, pressing
DELETE will enter the default string and
terminate the entry.
47
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Calibration Date - key in the calibration date
in numeric format, e.g. for 25 September 2001
enter 250901.
Calib. Date
:25/09/01
Installation Date - key in the calibration date
in numeric format, e.g. for 24 September 2001
enter 240901.
Install Date
:24/09/01
Tachograph Clock Speed - Press ENTER
and <> will appear on the display. Using the
← and → keys select either Normal or Fast
clock speed. Fast clock speed increases the
rate of rotation of the chart for test purposes.
Clock speed
:Normal
Note: Ensure that the clock speed is returned
to normal at the end of the test and before
sealing the tachograph.
Having entered the values to be programmed
into the tachograph, return to the MAIN MENU
by pressing menu button and now select
SEND ALL DATA (shortcut key 9).
KZ1319 MAIN MENU
:SEND ALL DATA
48
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
5.5
Programming MotoMeter EGK-100 tachographs
Parameters which may be programmed
•
K-factor
•
Pulses per engine revolution
Engine speed recording
bands
•
Connections
Select harness N. Connect one end of the harness to socket C on the Programmer. Connect the
other end to the 8-pin connector on the front of the tachograph.
Procedure
If appropriate read the current tachograph
setting prior to making changes.
EGK100 MAIN MENU
:READ ALL DATA
From the MAIN MENU select READ ALL
DATA (shortcut key 7) using the arrow keys ←
→, and then press ENTER to read data from
the tachograph.
When the Programmer indicates that the data
has been received return to the MAIN MENU
and this time select MODIFY DATA (shortcut
key 8) the arrow keys, and press ENTER.
EGK100 MAIN MENU
:MODIFY DATA
Select the parameters to be changed. Press
the ← or → keys to move between the
parameters to be entered.
EGK100 MAIN MENU
:READ ALL DATA
K-factor - Again press ENTER to change the
current value and enter the new value that was
stored during the W-factor measurement.
K-factor
:8000
Pulses per engine revolution - Press
ENTER and key in the new value. For the
MotoMeter tachograph values between 20.0
and 30.0 are valid. A 3-digit number should
be entered, and on completion of the entry
(press ENTER) the Programmer will insert a
decimal point between the last two digits.
Pulses per Rev
:20.8
49
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Engine speed recording bands - In each
case press ENTER to change the current
value and enter the new value.
Note: the Programmer will not allow the user
to enter inconsistent engine speed bands. For
example, the minimum speed for the
Economy band must be higher than the speed
defined for the Low Power band.
Low Power band
:900
Economy band
:1400
Poor Economy
:1600
Having entered the values to be programmed
into the tachograph, return to the MAIN MENU
by pressing Menu button and now select
SEND ALL DATA (shortcut key 9) by pressing
the arrow keys.
EGK100 MAIN MENU
:SEND ALL DATA
As instructed on the display, press ENTER to
send the data. On completion of the data
transfer the Programmer will indicate Data
Transfer OK.
Sending Data
Data Transfer OK
In the event of a problem, the message
Transfer FAILURE will be displayed. In that
event check the harness connection.
Transfer FAILURE
50
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
5.6
Programming SE5000 Series tachographs
Parameters which may be programmed
•
K-Factor
•
Tyre Size
•
Eng. Speed Rec.
•
Odometer
•
Next Calib. Date
•
VRESD
•
Current time
•
Veh. Reg. Nation
•
Veh. Speed Rec.
•
Current date
•
VRN
•
VRVSD
•
Time Offset
•
Speed Authorised
•
D5 pin function
•
Output Shaft Factor
•
Illum. Input
•
CAN trip reset
•
CANBus enabled
•
Revs Inp. C3/CAN
•
Pre-Overspeed
•
Speedo O/P Factor
•
Pref. Language
•
Pre-NextCalib
•
D6 pin function
•
CANBus type
•
Display Function
•
VIN
•
D7 pin function
•
Max.Warranty
•
Service delay
•
Serial Data Out
•
War.Valid Time
•
Install Date
•
Backlight Select
•
Warranty Time
•
Reset Heartbeat
•
Illumination Lvl
•
No. writes WT
•
D4 pin function
•
Illumination Off
•
Activation Time
•
Low Speed Limit
•
RPM Factor
•
W-factor
•
L-Factor
•
CAN Termination
•
Add. Event Rec.
51
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Connections
Table 13: Stoneridge SE5000 Programming connections
Tachograph
Harness
Connection
SE5000 Series
Z
DIN plug to socket C on Programmer and D-shaped connector to
socket on front of tachograph.
Procedure
Select READ ALL DATA from the main menu
and press ENTER.
SE5000 MAIN MENU
:READ ALL DATA
Select MODIFY DATA from the main menu
and press ENTER.
SE5000 MAIN MENU
:MODIFY DATA
Use the ← and → to select the parameter you
wish to alter.
K-factor - Press ENTER and type in the new
value. Press enter again to confirm the value.
K-factor
:8000
Odometer reading - Press ENTER and key in
the required new odometer reading. Bear in
mind that the last digit entered is the tenths
digit, thus a required reading of 100.0km
should be entered as 1000.
Odometer
: 21 055 406.0
Current time - Press ENTER and a cursor will
flash. Key in the current time and press
ENTER.
Current time
:10:35
Note the time should be set to UTC time.
Current date - Press ENTER and a cursor will
flash. Key in the current date and press
ENTER.
Current date
:19/10/2003
Note the time should be set to UTC time.
Time offset - Press ENTER and use the
up/down arrow keys to choose a time offset
between +23:00 and –23:00 hours and +59
and –59 minutes.
Time offset
:+1: +00
O/P shaft factor – Press ENTER and a cursor
will flash. Key in the required value and press
ENTER.
O/P shaft factor
:10.000
52
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
CANBus enabled - Press ENTER and use
the ← and → keys to select ON or OFF. Press
ENTER to confirm the selection.
CANBus enabled
Speedo OP factor - Press ENTER and a
cursor will flash.
Speedo OP factor
:4971
:On
Key in the required value and press ENTER.
D6 pin function - Press ENTER and use the
← and → keys to select OFF, Revs warning or
Speedometer.
D6 pin function
:OFF
VIN - Press ENTER and type the Vehicle
Identification Number.
VIN
:1234567890ABCDEFG
This can be up to 17 characters long. Press
ENTER to confirm the selection.
Service delay – Read Only.
Service delay
:104 weeks
Install date - Press ENTER and a cursor will
flash. Key in the date of installation of the
tachograph and press ENTER.
Install date
:19/09/2001
Reset Heartbeat - Press ENTER and use the
← and → keys to select ON or OFF. Press
ENTER to confirm the selection.
Reset Heartbeat
:Off
←→
Note: when set to ON the vehicle cluster
presence is confirmed by the tachograph.
D4 pin function - Press ENTER and use the
← and → keys to select DTC Warning, Chart
Change, Dynafleet, Low speed, Functions or
Off.
D4 pin function
←→
Low Speed Limit - Press ENTER and a
cursor will flash. Key in the Low Speed Limit
value.
Low Speed Limit
km/h
L-Factor – Press ENTER and a cursor will
flash. Key in the L-Factor value.
L-Factor
:1234 mm
Tyre Size - Press ENTER and type the Tyre
Size. This can be up to 15 characters long.
Press ENTER to confirm the selection.
Tyre Size
:1234567890ABCDE
Next Calib Date - Press ENTER and a cursor
will flash.
Next Calib Date
:19/10/2005
:Off
:5
Key in the next calibration date and press
ENTER.
53
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Vehicle Registration Nation - Press ENTER
and type the Vehicle Registration Nation. This
can be up to 3 characters long. Press ENTER
to
confirm
the
selection.
The Vehicle Registration Nation can also be
referred to as Registering Member State.
Veh. Reg. Nation
:123
VRN - Press ENTER and type the VRN. This
can be up to 13 characters long. Press
ENTER to confirm the selection.
VRN
:1234567890ABC
Speed Authorised - Press ENTER and a
cursor will flash.
Speed Authorised
:125 km/h
Key in the Speed authorised value.
Illumination Input - Press ENTER and use
the ← and → keys to select one of the
following options. OFF, CAN ONLY, A2 ONLY.
Illum. Input
:OFF
Revs Input C3/CAN - Press ENTER and use
the ← and → keys to choose between the
following options.
CAN ENABLED, C3
ENABLED.
Revs Inp. C3/CAN
:CAN ENABLED
Preferred Language - Press ENTER and the
cursor will flash. Enter the correct code for the
required language and press ENTER to
accept it.
Pref. Language
:en
CANBus type - Press ENTER and type the
CANbus type. This can be up to 2 digits long.
Press ENTER to confirm the selection.
CANBus type
D7 pin function - Press ENTER and use the
← and → keys to select DISABLE or ENABLE.
D7 pin function
:DISABLE
Serial Data Out - Press ENTER and use the
← and → keys to select one of the following
options. DISABLE, ENABLE SRE, ENABLE
2400.
Serial Data Out
:ENABLE SRE
Backlight Select - Press ENTER and use the
← and → keys to select one of the following
options. Colour 1, Colour 2, No Colour.
Backlight Select
:Colour 1
Illumination Lvl - Press ENTER and type the
Illumination Lvl. This can be up to 3 digits
long. Press ENTER to confirm the selection.
Illumination Lvl
:0
Illumination Off - Press ENTER and type the
Illumination Off. This can be up to 3 digits
Illumination Off
:24
:255
54
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
long. Press ENTER to confirm the selection.
RPM Factor - Press ENTER and type the
RPM Factor. This can be up to 5 digits long.
Press ENTER to confirm the selection.
RPM Factor
:12
CAN Termination - Press ENTER and use
the ← and → keys to select DISABLE or
ENABLE.
CAN Termination
:ENABLE
Add. Event Rec. - Press ENTER and use the
← and → keys to select DISABLE or ENABLE.
Add. Event Rec.
:ENABLE
Eng. Speed Rec. - Press ENTER and use the
← and → keys to select DISABLE or ENABLE.
Eng. Speed Rec.
:ENABLE
VRESD (Vu Ranges Engine Speed Data) Press ENTER and type the VRESD. This can
be up to 7 digits long. Press ENTER to
confirm the selection.
VRESD
:Rng1= 7999.875
Veh. Speed Rec. - Press ENTER and use the
← and → keys to select DISABLE or ENABLE.
Veh. Speed Rec.
:ENABLE
VRVSD (Vu Ranges Vehicle Speed Data) Press ENTER and type the VRVSD. This can
be up to 3 digits long. Press ENTER to
confirm the selection.
VRVSD
:Rng1= 111
D5 pin function - Press ENTER and use the
← and → keys to select DISABLE or ENABLE.
D5 pin function
CAN trip reset - Press ENTER and use the ←
and → keys to select ISO or MAN.
CAN trip reset
:MAN
Pre-Overspeed - Press ENTER and type the
Pre-Overspeed. This can be up to 2 digits
long. Press ENTER to confirm the selection.
Pre-Overspeed
:6
Once done a new screen will appear
requesting the input for TCO1 WARNING?,
use the ← and → keys to select DISABLE or
ENABLE.
Pre-NextCalib - Press ENTER and type the
Pre-NextCalib. This can be up to 3 digits long.
Press ENTER to confirm the selection.
:DISABLE
TCO1 WARNING?
:ENABLE
Pre-NextCalib
:111
55
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Display Function - Press ENTER and use
the ← and → keys to select DISABLE or
ENABLE.
Display Function
:ENABLE
Max.Warranty – This parameter is READ
ONLY.
Max. Warranty
MONTHS
War.Valid Time - This parameter is READ
ONLY.
War.Valid Time
:00/00/0000
Warranty Time - Press ENTER and type the
Warranty Time. This can be up to 2 digits
long. Press ENTER to confirm the selection.
Warranty Time
:30 MONTHS
No. writes WT - This parameter is READ
ONLY.
No. writes WT
Activation Time - This parameter is READ
ONLY.
Activation Time
:UNACTIVATED
W-Factor - Press ENTER and a cursor will
flash. Key in the W-Factor value.
W-Factor
:8000
Having entered the values to be programmed
into the tachograph, return to the MAIN MENU
by pressing Menu button and now select
SEND ALL DATA (shortcut key 9) by pressing
the arrow keys.
SE5000 MAIN MENU
:SEND ALL DATA
As instructed on the display, press ENTER to
send the data. On completion of the data
transfer the Programmer will indicate Data
Transfer OK.
Sending Data
Data Transfer OK
In the event of a problem, the message
Transfer FAILURE will be displayed. In that
event check the harness connection.
Transfer FAILURE
:36
:0
56
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
5.7
Programming DTCO Series tachographs
Parameters which may be programmed
•
K-Factor
•
Time Offset
•
Tyre Size
•
Odometer
•
Output shaft factor
•
Next Calibration Date
•
Current time
•
VIN
•
Vehicle Reg. Nation
•
Current date
•
L-Factor
•
W-Factor
•
Pulses Per Rev
•
Speed Authorised
•
Install Date
•
CANBus type
•
VRN
Connections
Table 13: DTCO Programming connections
Tachograph
Harness
Connection
DTCO Series
Z
DIN plug to socket C on Programmer and D-shaped connector to
socket on front of tachograph.
Procedure
Select READ ALL DATA from the main menu
and press ENTER.
DTCO MAIN MENU
:READ ALL DATA
Select MODIFY DATA from the main menu
and press ENTER.
DTCO MAIN MENU
:MODIFY DATA
Use the ← and → to select the parameter you
wish to alter.
K-factor - Press ENTER and type in the new
value. Press enter again to confirm the value.
K-factor
:8000
Odometer reading - Press ENTER and key in
the required new odometer reading.
Odometer
: 21 055 406.0
Bear in mind that the last digit entered is the
tenths digit, thus a required reading of
100.0km should be entered as 1000.
Current time - Press ENTER and a cursor will
Current time
57
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
flash. Key in the current time and press
ENTER.
:10:35
Note the time should be set to UTC time.
Current date - Press ENTER and a cursor will
flash. Key in the current date and press
ENTER.
Current date
:19/10/2003
Note the time should be set to UTC time.
Time offset - Press ENTER and use the
up/down arrow keys to choose a time offset
between +23:00 and –23:00 hours and +59
and –59 minutes.
Time offset
:+1: +00
Output shaft factor - It is not necessary to
change this value.
O/P shaft factor
:8.140
VIN - Press ENTER and type the Vehicle
Identification Number. This can be up to 17
characters long. Press ENTER to confirm the
selection.
VIN
:1234567890ABCDEFG
L-Factor – Press ENTER and a cursor will
flash. Key in the L-Factor value.
L-Factor
:1234 mm
Tyre Size - Press ENTER and type the Tyre
Size. This can be up to 15 characters long.
Press ENTER to confirm the selection.
Tyre Size
:1234567890ABCDE
Next Calib Date - Press ENTER and a cursor
will flash. Key in the next calibration date and
press ENTER.
Next Calib Date
:19/10/2005
Vehicle Registration Nation - Press ENTER
and type the Vehicle Registration Nation. This
can be up to 3 characters long. Press ENTER
to
confirm
the
selection.
The Vehicle Registration Nation can also be
referred to as Registering Member State.
Veh. Reg. Nation
:123
VRN - Press ENTER and type the VRN. This
can be up to 13 characters long. Press
ENTER to confirm the selection.
VRN
:1234567890ABC
Speed Authorised - Press ENTER and a
cursor will flash. Key in the Speed authorised
value.
Speed Authorised
:125 km/h
CANBus type - Press ENTER and type the
CANbus type. This can be up to 2 digits long.
Press ENTER to confirm the selection.
CANBus type
W-Factor - Press ENTER and a cursor will
W-Factor
:24
58
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
flash. Key in the W-Factor value.
:8000
Install date - Press ENTER and a cursor will
flash. Key in the date of installation of the
tachograph and press ENTER.
Install date
:19/09/2001
Pulses per Rev - Press ENTER and a
curser will flash. Enter the number required
and press ENTER again to accept.
Pulses per Rev
:4.000
CANBus Type - Press the ENTER key. This
will cause a flashing cursor to appear. Enter
the required number(0 – 99), and press
ENTER to confirm.
CANBus type
:01
Having entered the values to be programmed
into the tachograph, return to the MAIN MENU
by pressing Menu button and now select
SEND ALL DATA (shortcut key 9) by pressing
the arrow keys.
DTCO MAIN MENU
:SEND ALL DATA
As instructed on the display, press ENTER to
send the data. On completion of the data
transfer the Programmer will indicate Data
Transfer OK.
Sending Data
Data Transfer OK
In the event of a problem, the message
Transfer FAILURE will be displayed. In that
event check the harness connection.
Transfer FAILURE
59
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
5.8
Programming Smartach Series tachographs
Parameters which may be programmed
•
VIN
•
Current time
•
Current date
•
Time Offset
•
Odometer
•
K-factor
•
L-factor
•
W-factor
•
Tyre Size
•
Next Calibration date
•
Speed Authorised
•
Vehicle Reg. Nation
•
VRN
Connections
Table 13: Smartach Programming connections
Tachograph
Harness
Connection
Smartach
Series
Z
DIN plug to socket C on Programmer and D-shaped connector to
socket on front of tachograph.
Procedure
Select READ ALL DATA from the main menu
and press ENTER.
S.TACH MAIN MENU
:READ ALL DATA
Select MODIFY DATA from the main menu
and press ENTER.
S.TACH MAIN MENU
:MODIFY DATA
Use the ← and → to select the parameter you
wish to alter.
K-factor - Press ENTER and type in the new
value. Press enter again to confirm the value.
K-factor
:8000
Odometer reading - Press ENTER and key in
the required new odometer reading.
Odometer
: 21 055 406.0
Bear in mind that the last digit entered is the
tenths digit, thus a required reading of
100.0km should be entered as 1000.
60
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Current time - Press ENTER and a cursor will
flash. Key in the current time and press
ENTER.
Current time
:10:35
Note the time should be set to UTC time.
Current date - Press ENTER and a cursor will
flash. Key in the current date and press
ENTER.
Current date
:19/10/2003
Note the time should be set to UTC time.
Time offset - Press ENTER and use the
up/down arrow keys to choose a time offset
between +23:00 and –23:00 hours and +59
and –59 minutes.
Time offset
:+1: +00
VIN - Press ENTER and type the Vehicle
Identification Number.
VIN
:1234567890ABCDEFG
This can be up to 17 characters long. Press
ENTER to confirm the selection.
L-Factor – Press ENTER and a cursor will
flash. Key in the L-Factor value.
L-Factor
:1234 mm
Tyre Size - Press ENTER and type the Tyre
Size.
Tyre Size
:1234567890ABCDE
This can be up to 15 characters long. Press
ENTER to confirm the selection.
Next Calib Date - Press ENTER and a cursor
will flash. Key in the next calibration date and
press ENTER.
Next Calib Date
:19/10/2005
Vehicle Registration Nation - Press ENTER
and type the Vehicle Registration Nation. This
can be up to 3 characters long.
Veh. Reg. Nation
:123
Press ENTER to confirm the selection.
The Vehicle Registration Nation can also be
referred to as Registering Member State.
VRN - Press ENTER and type the VRN. This
can be up to 13 characters long. Press
ENTER to confirm the selection.
VRN
:1234567890ABC
Speed Authorised - Press ENTER and a
cursor will flash. Key in the Speed authorised
value.
Speed Authorised
:125 km/h
W-Factor - Press ENTER and a cursor will
flash. Key in the W-Factor value.
W-Factor
:8000
61
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Having entered the values to be programmed
into the tachograph, return to the MAIN MENU
by pressing Menu button and now select
SEND ALL DATA (shortcut key 9) by pressing
the arrow keys.
S.TACH MAIN MENU
:SEND ALL DATA
As instructed on the display, press ENTER to
send the data. On completion of the data
transfer the Programmer will indicate Data
Transfer OK.
Sending Data
Data Transfer OK
In the event of a problem, the message
Transfer FAILURE will be displayed. In that
event check the harness connection.
Transfer FAILURE
62
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
5.8
Reading of speed pulses from the front of Kienzle 1314, 1318 and 1319
When using a Tachograph Programmer with 1314, 1318 and 1319 tachographs, a minor
inconsistency occurs when using the front sockets. This has some effect when carrying out either
the K-Factor test, Bench test or the Speed simulator test using a jack plug.
The signal coming through the sender cable is a square waveform and therefore oscillates
between two states ‘high’ and ‘low’, If, at the time of performing a Bench test, the sender signal is
in its low state, then this ‘grounds’ the circuitry in the tachograph and gives the appearance that
the tachograph is inactive. There are two ways in which this can be overcome. Either disconnect
the sender or move the vehicle slightly forward. The table below recommends which method to
apply with which test:
Table 14: Kienzle 1314,1318, 1319 Speed Pulse Method
Bench Test
K-Factor Test
Speed Test
Disconnect Sender
Yes
Yes
No
*Move Vehicle slightly forward
No
Yes
Yes
• When carrying out either the K-factor test or the Speed test with the tachograph still mounted in
the cab of the vehicle, the more practical solution would be to roll the vehicle slightly forward (until the
tachograph speed pointer moves up to the correct speed being sent by the Programmer), then stop
the vehicle.
63
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
ANNEX A -
TEST HARNESSES FOR USE WITH THE TACHOGRAPH PROGRAMMER
Part Number
Harness Diagrams
Application
Yellow
(C)
7780-981
Socket A of Programmer
Tachograph
Drive Lead
6 pin DIN plug
To Socket B Tachograph
Yellow
Socket A of Programmer
Vehicle Sender
Connection
Lead
(D)
7780-982
6 pin DIN plug
Red
To Socket C
Tachograph
(E)
PPR/Engine
rev Calibration
Lead
Red
7780-983
5 pin DIN plug
“W” terminal
Alternator
Brown
(F)
7780-986
To Socket
D
Tachograp
h
4 mm Socket
Serial Data Out
Adapter Lead
Black - 0 volts
(G)
Socket A of programmer
Jack Socket
Connection
Lead
7780-984
Jack Plug to
Tachograph
5 pin DIN plug
Red
(H)
Socket B of programmer
To Serial Socket next
to DIL Switches
7780-989
Serial Data
Connection
Lead
4 pin DIN plug
Black - 0 volts
64
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Part Number
(I)
UK 7955-778
EURO -779
Harness Diagrams
Application
Socket A of programmer
Battery
Charger
5 pin DIN plug
To Mains Supply
To be pushed
on Black plugs
on harnesses
G or H
(J)
2714-377
“Crocodile Clip”
White
To socket
Km/h MPH
(L)
7780-988
White
Socket A of programmer
5 pin DIN plug
KZ1314 Drive
Lead W factor
Lead
To sender
“Note : 3 wire plug”
Yellow
Yellow
MotoMeter
bench test lead
adapter
(M)
7780-974
To Motometer
pulser socket
Minitimer pulser
connector
Socket C of programmer
(N)
7780-980
(O)
8 pin DIN plug
8 pin DIN plug
4mm Jack
socket
8 way connector
to Tacho
7780-979
MotoMeter
programming
lead
Kienzle 1319
K-factor lead
65
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Part Number
(P)
Harness Diagrams
Application
Connector to
Tacho
Socket C of programmer
Kienzle 1319
programming
lead
7780-973
8 pin DIN plug
To D Socket
(Violet)
(Q)
MotoMeter
Revs Adapter
Lead
7780-975
Jack socket
White
White
MotoMeter
Power Adapter
Lead
(R)
7780-976
(S)
To Motometer
power socket
Minitimer Power
connector
4mm socket
4mm Jack
7780-978
(T)
4mm socket
4mm Jack
7780-977
Flexible
extension for
use with
harness G
(KZ1318,
VR8400)
Flexible
extension for
use with
harness G
(KZ1314 only)
8 pin DIN plug
VR2400
Calibration/
programming
(U)
7780-954
6-pin D-shaped connector
66
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Part Number
Harness Diagrams
Application
VR2400/
VR8900/
K1324/
SE5000
Canbus
(V)
7780-956
To socket A on
tachograph
8 pin DIN plug
1324
Calibration/
programming
(W)
7780-952
D-shaped connector
8 pin DIN plug
To socket D on tachograph
2400 serial
data lead
(X)
7780-955
4mm socket
brown
Digital
tachograph
interface cable
(Z)
7945-013
8 pin DIN plug
D-shaped connector
Socket C of programmer
7955-938
SE Clock
Adapter
8 pin DIN plug
SE Clock Tester
Socket A of programmer
7780-946
5 pin DIN plug
Battery
Discharge
Device
67
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Part Number
7780-949
Harness Diagrams
6-pin female connector
Application
6-pin male connector
To PC Serial Port
To Socket D of
programmer
7780-953
RJ11 6-WAY
9-Way D-Type Socket
7955-777
To socket B on
Programmer
Flat Cable
Assembly for
Bench Test
(VR2400 only)
Field
Download
Cable Assy
(Note: Used for
Programmer
Software
Upgrades Only.
See section 1.4
for more details).
Flexi-switch is
used with the
“Fixed
Distance #2”
feature,
providing a
very simple
accurate
method of
vehicle
calibration.
Please note that all of the cables listed in Annex A are supplied as part of a standard Hand-held
programmer Kit EXCEPT the Flexi-Switch (7955-777) which must be purchased separately.
68
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
ANNEX B (a)
DETAILS OF BENCH TEST ROUTINES
UK Bench Test
Before performing the Bench Test, go to the Diagnostics menu and check that the UK Bench Test
is selected (see Section 2.6). At the end of the Benchtest perform the Clock Test (see section 4.7
for details).
From the MAIN MENU select BENCH TEST
using the ← and → keys, and press ENTER.
VR2400 MAINMENU
:BENCH TEST
Select the Tachograph scale (125 km/h, 140
km/h, 180 km/h, 100 km/h or 160 km/h) using
the ← and → keys, and press ENTER.
Select the scale
: 125 km/h ← →
Set the tachograph to a K-factor of 8000
(remember to note the original setting first), or
press delete and enter K factor required. The
display and the setting method will vary
according to the type of tachograph selected.
Press ENTER. For a VR2400 tachograph
benchtest, it is easier to read-in the K factor
first and use this value in the benchtest.
Select K-factor
:8000 Pul/km?
Select whether the change of Duty is to be
automatically changed or manually changed.
Auto Duty
: Off
<-->
Press ENTER to accept current settings or the
← and → keys to change.
Note: Auto Duty can only be programmed
via the front connector.
Perform the task displayed. Press ENTER on
completion. N.B. Some VR2400 tachographs
may not have a display in which case this
check can be omitted.
Check backlight
illuminated
Perform the task displayed. Press ENTER on
completion.
Prepare and
insert chart(s)
Note: For dual driver, 2 charts have to be
inserted. For a single driver, only 1 chart
has to be inserted.
Perform the task displayed. Press ENTER on
completion.
Driver=Active
Crew=Active
The speed will now be maximum speed for the
selected scale for 10 seconds, e.g. 125km/h,
and the time will count down to zero and then
an audible beep will be heard.
Speed: 125 km/h
Time: 10 s
69
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
The speed displayed will then go to 0km/h for
10 seconds (the time will count down to zero)
and an audible beep will be heard again.
Speed: 0 km/h
Time: 10 s
Note the current odometer reading on the
tachograph. This will be required later to
check the accuracy of the odometer. Press
ENTER.
Note odometer
reading
The speed will now go to 40km/h and will be
held for 2½ minutes (150 seconds – the time
will count down to zero). To move on to the
next test before the end of the normal time
press ENTER. At the end of the 2½ minute
test there will be an audible beep.
Speed: 40 km/h
Time: 150 s
The speed will then go up to 80 km/h. After a
further 2½ minutes (the time will count down to
zero) there will again be an audible beep
indicating the end of that test.
Speed: 80 km/h
Time: 150 s
The speed will move up to 100 km/h for a
further 3 minutes (time will count down to
zero). At the end of the time there will be a
further beep and the speed will return to zero.
Speed: 100 km/h
Time: 180 s
Perform the task displayed. Press ENTER on
completion.
Driver=Active
Crew=Active
The unit will record Active 4 duty for 2 minutes
(the time will count down to zero). After that
time an audible beep will be heard.
Recording duty
Time: 120 s
Perform the task displayed. Press ENTER on
completion.
Driver=Passive
Crew=Passive
The unit will record Passive 1 duty for 2
minutes (the time will count down to zero) and
then beep.
Recording duty
Time: 120 s
Perform the task displayed. Press ENTER on
completion.
Driver=Rest
Crew=Rest
The unit will record Rest 2 for 2 minutes (the
time will count down to zero) and then beep
Recording duty
Time: 120 s
Compare the new odometer reading with that
noted above - a difference of 10km is
expected.
Check odometer
added 10 km
The display will then show as opposite. Check
that the time on the chart corresponds with the
time indicated on the clock, then press
ENTER.
Check clock
to chart time
70
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
(b)
Remove the two chart(s) and check the
trace(s) (speed, duty and distance on chart 1,
duty on chart 2). Press ENTER.
Check chart rec.
Set K for veh.
Press the ENTER or MENU key to return to
the MAIN MENU.
VR2400 MAINMENU
:BENCH TEST
French Bench Test
Before performing the Bench Test, check that the French Bench Test is selected from the
Diagnostics menu (see Section 2.6). The speeds registered during the test will depend on the
Tachograph scale selected at Step 2. The relevant speeds for each scale, and the total distance
covered, are listed below:
Table 15: Speeds for French Bench Test
Scale
125 km/h
140 km/h
180 km/h
Step 13
125 km/h
140 km/h
180 km/h
Step 20
125 km/h
140 km/h
180 km/h
Step 22
40 km/h
40 km/h
40 km/h
Step 23
70 km/h
80 km/h
100 km/h
Step 24
100 km/h
120 km/h
160 km/h
Step 29
+16.75km
+19 km
+24 km
From the MAIN MENU select BENCH TEST
using the ← and → keys, and press ENTER.
VR2400 MAINMENU
:BENCH TEST
Select the scale of the tachograph (125 km/h,
140 km/h, 180 km/h only in France) using the
← and → keys, and press ENTER.
Select scale
:125 km/h ← →
Set the tachograph to a K-factor of 8000,
(remember to make a note of the original
setting), or press delete and enter K factor
required. The display and the setting method
will vary according to the type of tachograph
selected. Press ENTER.
Set K factor
:8000 Pul/km?
Select whether the change of Duty is to be
automatically changed or manually changed.
Auto Duty
: Off
<-->
Press ENTER to accept current settings or the
← and → keys to change.
71
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Note: Auto Duty can only be programmed
via the front connector.
Check the tachograph settings.
Check tacho
settings
Press ENTER.
Connect the drive lead. The precise lead
required will vary according to the type of
tachograph. After connection press ENTER.
Connect drive
lead to tacho
Set the power supply to 12 or 24V to match
the tachograph and turn on the supply. Press
ENTER.
Switch on at
correct voltage
For tachographs with a second hand or a
clock tell-tale check that the clock is stepping.
Check clock is
stepping OK
Perform the task displayed. Press ENTER on
completion.
Check bulbs are
illuminated
Perform the task displayed. Press ENTER on
completion.
Prepare and
insert 2 charts
Close the tachograph as appropriate for the
type of tachograph and press ENTER.
Close the
tachograph
Set both Driver 1 duty and Driver 2 duty to
Rest, 2 then press ENTER.
Driver=Rest
Crew=Rest
The speed will now be maximum speed for the
selected scale for 10 seconds, e.g. 125km/h,
and the time will count down to zero and then
an audible beep will be heard.
Speed: 125km/h
Time: 10s
The speed displayed will then go to 0km/h for
10 seconds (the time will count down to zero)
and an audible beep will be heard again.
Speed : 0km/h
Time : 10s
The display will then show as opposite. Check
that the time on the chart corresponds with the
time indicated on the clock, then press
ENTER.
Check clock
to chart time
Close the tachograph as appropriate for the
type of tachograph and press ENTER.
Close the
tachograph
Note the odometer reading.
Note odometer
reading
72
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Set Driver 2 to Active 4, then press ENTER.
Driver=Rest
Crew=Active
Note the time displayed on the Tachograph
clock.
Record time on
Tacho
The speed will go to maximum and will be held
for 3 minutes (180 seconds – the time will
count down to zero). At the end of the 3
minute test there will be an audible beep.
Speed: 125km/h
Time: 180s
The speed will return to 0km/h for a further 3
minutes (180 seconds – the time will count
down to zero), after which there will be an
audible beep.
Speed: 0km/h
Time: 180s
The speed will increase to the value shown in
Table 15. After 180 seconds (the time will
count down to zero) there will again be an
audible beep.
Speed: 40km/h
Time: 180s
The speed will increase to the value shown in
Table 15. After 180 seconds (the time will
count down to zero) there will again be an
audible beep.
Speed: 70km/h
Time: 180s
The speed will then will increase to the value
shown in Table 15. After 180 seconds (the
time will count down to zero) there will again
be an audible beep.
Speed: 100km/h
Time: 180s
Set both duty knobs to the passive position
(both 1), then press ENTER.
Driver=Passive
Crew=Passive
The unit will time 180s (the time will count
down to zero) of the duty, after which there will
again be an audible beep
Speed: 0km/h
Time: 180s
Set Driver 1 duty Active, 4, Driver 2 duty Rest,
2, then press ENTER.
Driver=Active
Crew=Rest
The unit will time another 180s (the time will
count down to zero) . After 180 seconds there
will again be an audible beep indicating
completion of the test.
Speed: 0km/h
Time: 180s
Check that the odometer reading has
increased over that noted previously, by
16.75km for 125 km/h scale, or 19km for
140km/h scale, or 24km for 180km/h scale
selected.
Check odometer
:+16.75km
73
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Remove the two charts and check the traces
(speed, duty and distance on chart 1, duty on
chart 2). Press ENTER.
Check chart
recordings
Reset the K-factor of the tachograph to the
correct value for the vehicle (as noted at Step
3). Press ENTER.
Set K-exact
for vehicle
Switch off the power and disconnect the
tachograph.
SWITCH OFF
POWER SUPPLY
Press the ENTER or MENU key to return to the MAIN MENU.
(c)
German Bench Test
Before performing the Bench Test, check that the German Bench Test is selected in the
Diagnostics menu (see section 2.6). The speeds registered during the test will depend on the
Tachograph scale selected at Step 2. The relevant speeds for each scale are listed below:
Table 16: Speeds for German Bench Test
Scale
Speeds: 1
100 km/h
170 km/h
125 km/h
170 km/h
140 km/h
170 km/h
160 km/h
170 km/h
180 km/h
170 km/h
2
180 km/h
180 km/h
180 km/h
180 km/h
180 km/h
3
0 km/h
0 km/h
0 km/h
0 km/h
0 km/h
4
90 km/h
115 km/h
130 km/h
150 km/h
170 km/h
5
100 km/h
125 km/h
140km/h
160 km/h
180 km/h
6
30 km/h
40 km/h
40 km/h
60 km/h
40 km/h
7
60 km/h
80 km/h
80 km/h
100 km/h
100 km/h
8
90 km/h
120 km/h
120 km/h
140 km/h
160 km/h
9
100 km/h
125 km/h
140 km/h
160 km/h
180 km/h
10
90 km/h
120 km/h
120 km/h
140 km/h
160 km/h
11
60 km/h
80 km/h
80 km/h
100 km/h
100 km/h
12
30 km/h
40 km/h
40 km/h
60 km/h
40 km/h
13
30 km/h
40 km/h
40 km/h
60 km/h
40 km/h
14
60 km/h
80 km/h
80 km/h
100 km/h
100 km/h
15
80 km/h
110 km/h
110 km/h
110 km/h
150 km/h
16
90 km/h
120 km/h
120 km/h
140 km/h
160 km/h
17
90 km/h
115 km/h
130 km/h
150 km/h
170 km/h
18
100 km/h
125 km/h
140 km/h
160 km/h
180 km/h
19
90 km/h
120 km/h
120 km/h
140 km/h
160 km/h
20
60 km/h
80 km/h
80 km/h
100 km/h
100 km/h
21
30 km/h
40 km/h
40 km/h
60 km/h
40 km/h
74
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
From the MAIN MENU select BENCH TEST
using the ← and → keys, and press ENTER.
VR2400 MAINMENU
:BENCH TEST
Select the Tachograph scale (125 km/h, 140
km/h, 180 km/h, 100 km/h or 160 km/h).
Select the scale
: 125 km/h ← →
Set the tachograph to a K-factor of 8000
(remember to note the original setting first), or
press delete and enter K factor required. The
display and the setting method will vary
according to the type of tachograph selected.
Press ENTER.
Select K-factor
:8000 Pul/km?
Select whether the change of Duty is to be
automatically changed or manually changed.
Auto Duty
: Off
<-->
Press ENTER to accept current settings or the
← and → keys to change.
Note: Auto Duty can only be programmed
via the front connector.
Perform the task displayed. Press ENTER on
completion.
Check tacho
settings
Connect the drive lead. The precise lead
required will vary according to the type of
tachograph. After connection press ENTER.
Connect drive
lead to tacho
Set the power supply to 12 or 24V to match
the tachograph and turn on the supply. Press
ENTER.
Switch on at
correct voltage
For tachographs with a second hand or a
clock tell-tale check that the clock is stepping.
Press ENTER on completion.
Check clock is
stepping OK
Perform the task displayed. Press ENTER on
completion.
Check bulbs are
illuminated
The Programmer provides a specific clock
check facility incorporating a clock tester for
the VR2400, K1324 and MotoMeter EGK-100
tachographs. The clock test should be carried
out at the end of the benchtest for these
tachographs. #
Check clock for
accuracy
75
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
For other tachographs a separate clock tester
will be required. Press ENTER to confirm that
the accuracy has been tested, or exit the
Benchtest (Press MENU) to perform the clock
test procedure.
Perform the task displayed. Press ENTER on
completion.
Prepare and
insert 2 charts
Close the tachograph as appropriate for the
type of tachograph and press ENTER.
Close the
tachograph
The speed will now be 170 km/h (speed ‘1’ in
Table 16) for 5 seconds, the time will count
down to zero and then an audible beep will be
heard.
Speed : 170 km/h
Time : 5 s
The speed will now increase to 180 km/h
(speed ‘2’ in Table 16) for 10 seconds, the
time will count down to zero and then an
audible beep will be heard.
Speed : 180 km/h
Time : 10 s
The speed will drop to 0 km/h (Speed ‘3’ in
Table 16). An audible beep will be heard after
10 seconds (the time will count down to zero).
Speed : 0 km/h
Time : 10 s
Check that the time on the chart corresponds
with the time indicated on the clock, then
press ENTER on completion.
Check clock
to chart time
Move the chart on 3 minutes by advancing the
clock. Press ENTER. For the VR2400,
K1319 & K1324 the clock cannot be advanced
manually, and the instruction is WAIT for the
time to count down to zero.
Advance chart
Time: 180 s
Close the tachograph as appropriate for the
type of tachograph and press ENTER. (Note:
This screen does not appear for the K1319).
Close the
tachograph
The speed will now be speed ‘4’ (as shown in
Table 16) for 5 seconds, the time will count
down to zero and then a beep will be heard.
Speed : 115 km/h
Time : 5 s
The speed will now go to the maximum for the
selected scale (speed ‘5’ as shown in Table
16) and will be held for 120 seconds (the time
will count down to zero).
Speed: 125 km/h
Time: 120 s
To move on to the next test before the end of
the normal time press ENTER. At the end of
the 2 minute test there will be an audible beep.
76
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Open the tachograph and move the chart on 3
minutes by advancing the clock. Close the
tachograph again and press ENTER.
Advance chart
Time: 180 s
If no keys are pressed the time count down to
zero and then move on to the next stage
automatically.
The speed will then go to the speed shown in
Table 16 (speed ‘6’). After 15 seconds (the
time will count down to zero) there will be an
audible beep.
Speed: 40 km/h
Time: 15 s
The speed will then go up to the speed shown
in Table 16 (speed ‘7’). After 15 seconds (the
time will count down to zero) there will again
be an audible beep.
Speed: 80 km/h
Time: 15 s
The speed will then go up to the speed shown
in Table 16 (speed ‘8’). After 15 seconds (the
time will count down to zero) there will again
be an audible beep.
Speed: 120 km/h
Time: 15 s
The speed will then go up to maximum (speed
‘9’ as shown in Table 16). After 5 seconds
(the time will count down to zero) there will
again be an audible beep.
Speed: 125 km/h
Time: 5 s
The speed will then go down to the speed
shown in Table 16 (speed ‘10’). After 15
seconds (the time will count down to zero)
there will again be an audible beep.
Speed: 120 km/h
Time: 15 s
The speed will then go down to the speed
shown in Table 16 (speed ‘11’). After 15
seconds (the time will count down to zero)
there will again be an audible beep.
Speed: 80 km/h
Time: 15 s
The speed will then go down to the speed
shown in Table 16 (speed ‘12’). After 15
seconds (the time will count down to zero)
there will again be an audible beep and the
speed will return to 0 km/h.
Speed: 40 km/h
Time: 15 s
Open the tachograph and move the chart on 3
minutes by advancing the clock. Close the
tachograph again and press ENTER. If no
keys are pressed the time count down to zero
and then move on to the next stage
automatically.
Advance chart
Time: 180 s
The speed will then go up to the speed shown
in Table 16 (speed ‘13’). After 5 seconds (the
time will count down to zero) there will again
be a beep and the speed will return to 0 km/h.
Speed: 40 km/h
Time: 5 s
77
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Open the tachograph and move the chart on 3
minutes by advancing the clock. Close the
tachograph again and press ENTER.
Advance chart
Time: 180 s
If no keys are pressed the time will count
down to zero and then move on to the next
stage automatically.
The speed will then go up to the speed shown
in Table 16 (speed ‘14’). After 10 seconds (the
time will count down to zero) there will again
be a beep and the speed will return to 0 km/h.
Speed: 80 km/h
Time: 10 s
Open the tachograph and move the chart on 3
minutes by advancing the clock. Close the
tachograph again and press ENTER.
Advance chart
Time: 180 s
If no keys are pressed the time will count
down to zero and then go to the next stage
automatically.
The speed will then go up to the speed shown
in Table 16 (speed ‘15’). After 10 seconds (the
time will count down to zero) there will again
be a beep and the speed will return to 0 km/h.
Speed: 110 km/h
Time: 5 s
The speed will then go up to the speed shown
in Table 16 (speed ‘16’). After 10 seconds (the
time will count down to zero) there will again
be a beep.
Speed: 120 km/h
Time: 10 s
Open the tachograph and move the chart on 3
minutes by advancing the clock. Close the
tachograph again and press ENTER.
Advance chart
Time: 180 s
If no keys are pressed the time will count
down to zero and then move on to the next
stage automatically.
The speed will move down to the speed
shown in Table 16 (speed ‘17’) for a further 2
minutes (the time will count down to zero).
At the end of the time there will be a further
beep.
Speed: 115 km/h
Time: 5 s
The speed will then go up to the maximum
speed (as shown in Table 16 - speed ‘18’).
After 10 seconds (the time will count down to
zero) there will again be a beep.
Speed: 125 km/h
Time: 10 s
The speed will move down to the speed
shown in Table 16 (speed ‘19’) for a further 2
minutes (the time will count down to zero).
At the end of this time there will be a beep.
Speed: 120 km/h
Time: 120 s
78
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
The speed will move down to the speed
shown in Table 16 (speed ‘20’) for a further 2
minutes (the time will count down to zero).
At the end of this time there will again be a
beep.
Speed: 80 km/h
Time: 120 s
The speed will move down to the speed
shown in Table 16 (speed ‘21’) for a further 2
minutes (the time will count down to zero).
At the end of the time there will be a further
beep and the speed will return to 0 km/h.
Speed: 40 km/h
Time: 120 s
Perform the task displayed. Press ENTER on
completion.
Driver=Active
Crew=Active
The unit will record active 4 duty time for 180
seconds, after which time a beep will be
heard.
Recording duty
Time: 180 s
Perform the task displayed. Press ENTER on
completion.
Driver=Passive
Crew=Passive
The unit will record passive 1 duty time for 180
seconds, after which time a beep will be
heard.
Recording duty
Time: 180 s
Perform the task displayed. Press ENTER on
completion.
Driver=Rest
Crew=Rest
The unit will record rest 2 for 180 seconds,
after which time a beep will be heard.
Recording duty
Time: 180 s
Remove the two charts and check the traces
(speed, duty and distance on chart 1, duty on
chart 2). Press ENTER.
Check chart
recordings
Reset the K-factor of the tachograph to the
correct value for the vehicle (as noted at Step
3). Press ENTER.
Set K-exact
for vehicle
Switch off the power and disconnect the
tachograph.
SWITCH OFF
POWER SUPPLY
Press the ENTER or MENU key to return to
the MAIN MENU.
VR2400 MAINMENU
:BENCH TEST
79
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
(d)
Swedish Bench Test
Before performing the Bench Test, check that the Swedish Bench Test is selected in the
Diagnostics menu (see section 2.6).
From the MAIN MENU select BENCH TEST
using the ← and → keys, and press ENTER.
VR2400 MAIN MENU
:BENCH TEST
Select the required Tachograph scale (i.e.,
125 km/h, 140 km/h, 180 km/h or 100 km/h).
Select the scale
: 125 km/h ← →
Set the tachograph to a K-factor of 8000
(remember to note the original setting first), or
press delete and enter K factor required. The
display and the setting method will vary
according to the type of tachograph selected.
Press ENTER.
Select K factor
:8000 Pul/km?
Select whether the change of Duty is to be
automatically changed or manually changed.
Auto Duty
: Off
<-->
Press ENTER to accept current settings or the
← and → keys to change.
Note: Auto Duty can only be programmed via the
front connector.
Perform the task displayed. Press ENTER on
completion.
Check bulbs are
illuminated
The Programmer provides a specific clock
check facility incorporating a clock tester for
the VR2400, K1324 and MotoMeter EGK-100
tachographs. The clock test should be carried
out at the end of the benchtest for these
tachographs. For other tachographs a
separate clock tester will be required. Press
ENTER to confirm that the accuracy has been
tested, or exit the Benchtest (Press MENU) to
perform the clock test procedure.
Check clock for
accuracy
Perform the task displayed. Press ENTER on
completion.
Prepare and
insert 2 charts
Note the current odometer reading on the
tachograph. This will be required later to
check the accuracy of the odometer. Press
ENTER.
Note odometer
reading
Set both duty knobs to Active 4
and press ENTER on completion. Note: when
testing VR1400 tachographs the driver knob
should be set to Drive.
Driver=Active
Crew=Active
80
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
The speed will now be maximum speed for the
selected scale for 10 seconds, e.g. 125km/h,
and the time will count down to zero and then
an audible beep will be heard.
Speed: 125 km/h
Time: 10 s
The speed displayed will then go to 0km/h for
10 seconds (the time will count down to zero)
and an audible beep will be heard again.
Speed: 0 km/h
Time: 10 s
Close the tachograph as appropriate for the
type of tachograph and press ENTER.
Close the
tachograph
The speed displayed will then go to 125km/h
for 10 seconds (the time will count down to
zero) and a beep will be heard.
Speed: 125 km/h
Time: 10 s
The speed will then go to 50km/h for 490
seconds (the time will count down to zero) and
a beep will be heard.
Speed: 50 km/h
Time: 490 s
The speed will go up to 100 km/h for 90
seconds (the time will count down to zero) and
a beep will be heard.
Speed: 100 km/h
Time: 90 s
The speed will go up to 125km/h for 10
seconds (the time will count down to zero) and
a beep will be heard.
Speed: 125 km/h
Time: 10 s
Set both duty knobs to Rest, 2, and press
ENTER on completion.
Driver=Rest
Crew=Rest
The unit will record duty time for 120 seconds
(the time will count down to zero). After that
time a beep is heard.
Recording duty
Time: 120s
Set both duty knobs to Passive, 1, and press
ENTER on completion.
Driver=Passive
Crew=Passive
The unit will record duty for 120 seconds (the
time will count down to zero). After that time a
beep is heard.
Recording duty
Time: 120s
Set both duty knobs to active, 4, and press
ENTER on completion.
Driver=Active
Crew=Active
The unit will record duty time for 120 seconds
(the time will count down to zero). After that
time a beep is heard.
Recording duty
Time: 120s
Look at the odometer reading and compare it
to the start to check that it has increased by
10km.
Check odometer
added 10 km
81
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
(e)
Open the tachograph, remove the charts and
check the recordings are as they should be.
Check chart
recordings
Switch off the tachograph.
SWITCH OFF
POWER SUPPLY
Program now returns automatically to the
MAIN MENU.
VR2400 MAIN MENU
:BENCH TEST
Dutch Bench Test
Before performing the Bench Test, check that the Dutch Bench Test is selected in the Diagnostics
menu (see section 2.6). The speeds registered during the test will depend on the Tachograph
scale selected at Step 2.
The relevant speeds for each scale are listed below:
Table 17: Speeds for Dutch Bench Test
Scale
Speeds: 1
100 km/h
90 km/h
125 km/h
120 km/h
140 km/h
120 km/h
160 km/h
140 km/h
180 km/h
160 km/h
2
0 km/h
0 km/h
0 km/h
0 km/h
0 km/h
3
0 km/h
0 km/h
0 km/h
0 km/h
0 km/h
4
30 km/h
40 km/h
40 km/h
60 km/h
40 km/h
5
60 km/h
80 km/h
80 km/h
100 km/h
100 km/h
6
90 km/h
120 km/h
120 km/h
140 km/h
160 km/h
7
100 km/h
125 km/h
140 km/h
160 km/h
180 km/h
8
90 km/h
120 km/h
120 km/h
140 km/h
160 km/h
9
60 km/h
80 km/h
80 km/h
100 km/h
100 km/h
10
30 km/h
40 km/h
40 km/h
60 km/h
140 km/h
11
90 km/h
120 km/h
120 km/h
140 km/h
160 km/h
12
0 km/h
0 km/h
0 km/h
0 km/h
0 km/h
From the MAIN MENU select BENCH TEST
using the ← and → keys, and press ENTER.
VR2400 MAINMENU
:BENCH TEST
Select the Tachograph scale required (i.e.,
125 km/h, 140 km/h, 180 km/h, 100 km/h or
160 km/h).
Select the scale
: 125 km/h ← →
Set the tachograph to a K-factor of 8000
(remember to note the original setting first), or
press delete and enter the K factor required.
The display and the setting method will vary
according to the type of tachograph selected.
Press ENTER on completion.
Select K-factor
:8000 Pul/km?
82
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Select whether the change of Duty is to be
automatically changed or manually changed.
Auto Duty
: Off
<-->
Press ENTER to accept current settings or the
← and → keys to change.
Note: Auto Duty can only be programmed
via the front connector.
Perform the task displayed. Press ENTER on
completion.
Check tacho
settings
Connect the drive lead. The precise lead
required will vary according to the type of
tachograph. After connection press ENTER.
Connect drive
lead to tacho
Set the power supply to 12 or 24V to match
the tachograph and turn on the supply. Press
ENTER on completion.
Switch on at
correct voltage
Only for tachographs with a second hand or a
clock tell-tale, check that the clock is stepping.
Press ENTER on completion.
Check clock is
stepping OK
Perform the task displayed. Press ENTER on
completion.
Check bulbs are
illuminated
The Programmer provides a specific clock
check facility incorporating a clock tester for
the VR2400, K1324 and MotoMeter EGK-100
tachographs. The clock test should be carried
out at the end of the benchtest for these
tachographs. For other tachographs a
separate clock tester will be required. Press
ENTER to confirm that the accuracy has been
tested, or exit the Benchtest (Press MENU) to
perform the clock test procedure.
Check clock for
accuracy
Perform the task displayed. Press ENTER on
completion.
Prepare and
insert 2 charts
Close the tachograph as appropriate for the
type of tachograph and press ENTER.
Close the
tachograph
Set both duty knobs to Rest, 2, and press
ENTER on completion.
Driver=Rest
Crew=Rest
The speed will now be speed ‘1’ (as shown in
Table 17) for 10 seconds, the time will count
down to zero and then an audible beep will be
heard.
Speed: 120 km/h
Time: 10 s
The speed displayed will then go to 0km/h for
10 seconds (the time will count down to zero)
and an audible beep will be heard again.
Speed: 0 km/h
Time: 10 s
83
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
The display will then show as opposite. Check
that the time on the chart corresponds with the
time indicated on the clock, then press
ENTER.
Check clock
to chart time
The speed will remain at 0 km/h for 2 minutes
(120 seconds - the time will count down to
zero) and then an audible beep will be heard.
To move on to the next test before the end of
the normal time press ENTER.
Speed: 0 km/h
Time: 120 s
The speed will then go up to speed ‘4’ shown
in Table 17. After 120 seconds (the time will
count down to zero) there will again be an
audible beep. To move on to the next test
before the end of the normal time press
ENTER.
Speed: 40 km/h
Time: 120 s
The speed will then go up to speed ‘5’ shown
in Table 17. After 120 seconds (the time will
count down to zero) there will again be an
audible beep. To move on to the next test
before the end of the normal time press
ENTER.
Speed: 80 km/h
Time: 120 s
The speed will then go up to speed ‘6’ shown
in Table 17. After 120 seconds (the time will
count down to zero) there will again be an
audible beep. To move on to the next test
before the end of the normal time press
ENTER.
Speed: 120 km/h
Time: 120 s
The speed will then go up to speed ‘7’ shown
in Table 17. After 120 seconds (the time will
count down to zero) there will again be an
audible beep. To move on to the next test
before the end of the normal time press
ENTER.
Speed: 125 km/h
Time: 120 s
The speed will then go down to speed ‘8’
shown in Table 17. After 120 seconds (the
time will count down to zero) there will again
be an audible beep. To move on to the next
test before the end of the normal time press
ENTER.
Speed: 120 km/h
Time: 120 s
The speed will then go down to speed ‘9’
shown in Table 17. After 120 seconds (the
time will count down to zero) there will again
be an audible beep. To move on to the next
test before the end of the normal time press
ENTER.
Speed: 80 km/h
Time: 120 s
84
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
The speed will then go down to speed ‘10’
shown in Table 17. After 120 seconds (the
time will count down to zero) there will again
be an audible beep. To move on to the next
test before the end of the normal time press
ENTER.
Speed: 40 km/h
Time: 120 s
The speed will then go up to speed ‘11’ shown
in Table 17. After 120 seconds (the time will
count down to zero) there will again be an
audible beep. To move on to the next test
before the end of the normal time press
ENTER.
Speed: 120 km/h
Time: 120 s
The speed will now go to 0 km/h and will be
held for 2 minutes (120 seconds - the time will
count down to zero). To move on to the next
test before the end of the normal time press
ENTER. At the end of the 2 minute test there
will be an audible beep.
Speed: 0 km/h
Time: 120 s
Set both duty knobs to active, 4, and press
ENTER on completion.
Driver=Active
Crew=Active
The unit will record duty time for 120 seconds
(the time will count down to zero). After that
time a beep is heard.
Recording duty
Time: 120 s
Remove the two charts and check the traces
(speed, duty and distance on chart 1, duty on
chart 2). Press ENTER.
Check chart
recordings
Reset the K-factor of the tachograph to the
correct value for the vehicle (as noted at Step
3). Press ENTER.
Set K-exact
for vehicle
Switch off the power and disconnect the
tachograph.
SWITCH OFF
POWER SUPPLY
Press the ENTER or MENU key to return to
the MAIN MENU.
VR2400 MAINMENU
:BENCH TEST
85
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
(f)
Belgian Bench Test
Before performing the Bench Test, check that the Belgian Bench Test is selected in the
Diagnostics menu (see section 2.6). The maximum speed registered during the test will depend
on the Tachograph scale selected at Step 2 below.
From the MAIN MENU select BENCH TEST
using the ← and → keys, and press ENTER.
VR2400 MAINMENU
:BENCH TEST
Select the Tachograph scale required (i.e.,
125 km/h, 140 km/h, 180 km/h, 100 km/h or
160 km/h).
Select the scale
: 125 km/h ← →
Set the tachograph to a K-factor of 8000
(remember to note the original setting first), or
press delete and enter the K factor required.
The display and the setting method will vary
according to the type of tachograph selected.
Press ENTER on completion.
Select K-factor
:8000 Pul/km?
Select whether the change of Duty is to be
automatically changed or manually changed.
Auto Duty
: Off
<-->
Press ENTER to accept current settings or the
← and → keys to change.
Note: Auto Duty can only be programmed
via the front connector.
Perform the task displayed. Press ENTER on
completion.
Check tacho
settings
Connect the drive lead. The precise lead
required will vary according to the type of
tachograph. After connection press ENTER.
Connect drive
lead to tacho
Set the power supply to 12 or 24V to match
the tachograph and turn on the supply. Press
ENTER on completion.
Switch on at
correct voltage
Only for tachographs with a second hand or a
clock tell-tale, check that the clock is stepping.
Press ENTER on completion.
Check clock is
stepping OK
Perform the task displayed. Press ENTER on
completion.
Check bulbs are
illuminated
Perform the task displayed. Press ENTER on
completion.
Prepare and
insert 2 charts
Close the tachograph as appropriate for the
type of tachograph and press ENTER.
Close the
tachograph
86
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Set both duty knobs to active, 4, and press
ENTER on completion.
Driver=Active
Crew=Active
The speed displayed will then go to 60km/h for
10 seconds (the time will count down to zero)
and then an audible beep will be again.
Speed: 60 km/h
Time: 10 s
The speed displayed will then go to 0km/h for
10 seconds (the time will count down to zero)
and an audible beep will be heard again.
Speed: 0 km/h
Time: 10 s
Open the tachograph as appropriate for the
type of tachograph and press ENTER.
Open the
tachograph
The display will then show as opposite. Check
that the time on the chart corresponds with the
time indicated on the clock, then press
ENTER.
Check clock
to chart time
Close the tachograph as appropriate for the
type of tachograph and press ENTER.
Close the
tachograph
Note the current odometer reading on the
tachograph. This will be required later to
check the accuracy of the odometer. Press
ENTER.
Note odometer
reading
Set both duty knobs to active, 4, and press
ENTER on completion.
Driver=Active
Crew=Active
Note the time displayed on the Tachograph
clock.
Record time on
Tacho
The speed ’39,0km/h’ will then be displayed
on the Programmer. Press ENTER to
continue.
Speed39,0km/h
Press <ENTER>
Use the ↑ and ↓ (7 and 4) keys to increase or
reduce the speed indicated by the speed
pointer on the cluster until it is exactly 40km/h.
Press ENTER to continue.
↑↓Pointer to 40
39,0 km/h
The final speed selected will be shown and
after 120 seconds (the time will count down to
zero) there will be an audible beep. To move
on to the next test before the end of the
normal time press ENTER.
Speed40,0km/h
Time: 120 s
The speed ’79,0km/h’ will then be displayed
on the Programmer. Press ENTER to
continue.
Speed79,0km/h
Press <ENTER>
87
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Use the ↑ and ↓ (7 and 4) keys to increase or
reduce the speed indicated by the speed
pointer on the cluster until it is exactly 80km/h.
Press ENTER to continue.
↑↓Pointer to 80
79,0 km/h
The final speed selected will be shown and
after 120 seconds (the time will count down to
zero) there will be an audible beep. To move
on to the next test before the end of the
normal time press ENTER.
Speed80,0km/h
Time: 120 s
The maximum speed (minus 1 km/h) for the
currently selected scale e.g. ‘124,0km/h’ will
then be displayed on the Programmer. Press
ENTER to continue.
Speed124,0km/h
Press <ENTER>
Use the ↑ and ↓ (7 and 4) keys to increase or
reduce the speed indicated by the speed
pointer on the cluster until it is exactly
maximum speed (e.g. 125km/h). Press
ENTER to continue.
↑↓Pointer to 125
124,0 km/h
The final speed selected will be shown and
after 120 seconds (the time will count down to
zero) there will be an audible beep. To move
on to the next test before the end of the
normal time press ENTER.
Speed125,0km/h
Time: 120 s
The speed ‘101.0km/h’ will then be displayed
on the Programmer. Press ENTER to
continue.
Speed101,0km/h
Press <ENTER>
Use the ↑ and ↓ (7 and 4) keys to increase or
reduce the speed indicated by the speed
pointer on the cluster until it is exactly
100km/h. Press ENTER to continue.
↑↓Pointer to 100
101,0 km/h
The final speed selected will be shown and
after 120 seconds (the time will count down to
zero) there will be an audible beep. To move
on to the next test before the end of the
normal time press ENTER.
Speed100,0km/h
Time: 120 s
The speed ‘61.0km/h’ will then be displayed
on the Programmer. Press ENTER to
continue.
Speed61,0km/h
Press <ENTER>
Use the ↑ and ↓ (7 and 4) keys to increase or
reduce the speed indicated by the speed
pointer on the cluster until it is exactly 60km/h.
Press ENTER to continue.
↑↓Pointer to 60
61,0 km/h
88
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
The final speed selected will be shown and
after 120 seconds (the time will count down to
zero) there will be an audible beep. To move
on to the next test before the end of the
normal time press ENTER.
Speed60,0km/h
Time: 120 s
Set both duty knobs to active, 4, and press
ENTER on completion.
Driver=Active
Crew=Active
The unit will record duty time for 120 seconds
(the time will count down to zero). After that
time a beep is heard. To move on to the next
test before the end of the normal time press
ENTER.
Active
Time: 120 s
Set both duty knobs to Passive, 1, and press
ENTER on completion.
Driver=Passive
Crew=Passive
The unit will record duty for 120 seconds (the
time will count down to zero). After that time a
beep is heard. To move on to the next test
before the end of the normal time press
ENTER.
Passive
Time: 120s
Set both duty knobs to Rest, 2, and press
ENTER on completion.
Driver=Rest
Crew=Rest
The unit will record duty time for 120 seconds
(the time will count down to zero). After that
time a beep is heard.
Rest
Time: 120s
Check that the odometer reading has
increased over that noted previously, by the
amount shown. (Note: this will vary for each
scale type selected and also depending on
how long it takes to adjust each speed setting
up or down).
Check odometer
+26.705km
Remove the two charts and check the traces
(speed, duty and distance on chart 1, duty on
chart 2). Press ENTER.
Check chart
recordings
Press the ENTER or MENU key to return to
the MAIN MENU.
VR2400 MAINMENU
:BENCH TEST
89
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
(g)
Programming of a Custom Bench Test
Custom Bench Tests may be programmed from the DIAGNOSTICS MENU. To access the
Diagnostics menu, hold down the ENTER key while switching the Programmer on.
To prevent unintentional use of the Diagnostic
functions, a pass code will be requested.
Type in 8642, and press ENTER.
Enter Code
:8642
Select Benchtest Type, using the arrow keys
(← →) and press ENTER.
DIAGNOSTICS MENU
:Benchtest type
Select bench-test type Custom using the
arrow keys (← →) then press ENTER.
Benchtest Type
:Custom ← →
A series of 15 screens similar to that shown
opposite are then presented in turn. Each
defines one stage of the speed test. To move
to the definition of the next stage press →; to
move to the previous stage press ←; to
change the definition of that stage press
ENTER.
1 Time = 250 s
Speed 80 km/h
Having pressed ENTER, enter the required
speed for that stage of the test. If the entered
speed is lower than the 10km/h, then it will
automatically reset to 0km/h. Terminate the
entry by pressing ENTER.
Enter speed
:
km/h
Then enter the required time for the stage (in
seconds) again terminating the entry with
ENTER. Thereafter press → to move on to
the next stage. Setting the test time to zero will
cause the unit to skip on to the next stage
having a time greater than zero.
Enter time
:
s
Stages 16 to 20 allow definition of test stages
where different duty modes are recorded - this
must be carried out without speed since
automatic tachographs would otherwise record
Drive. To move to the definition of the next
stage press →; to move to the previous stage
press ←; to change the definition of that stage
press ENTER.
16 Time= 120 s
Duty=Active
The Programmer will then display a screen
similar to the one shown. Use the ← and →
arrow keys to select the required duty
mode for both Driver 1 and Driver 2 then press
ENTER.
Select duty
: Active ← →
90
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Again enter the required test time and
terminate the entry by pressing ENTER. As
before enter zero time to cause that stage to
be skipped.
Enter time
:
s
After stage 20 has been completed, stage 1
appears on the screen again.
1 Time = 250 s
Speed 80 km/h
Press the MENU key once to return to the
DIAGNOSTICS MENU.
DIAGNOSTICS MENU
:Benchtest type
On completion of the required bench test definition press MENU twice to return to the MAIN MENU.
The test sequence just entered will be memorised until it is next changed and will be the selected
Bench Test type. If a pre-programmed bench test type is subsequently selected the details of the
entered Custom test sequence will remain in the Programmer memory.
(h)
Digtial Tachograph Bench Test
From the MAIN MENU select BENCH TEST
using the ← and → keys, and press ENTER.
SE5000 MAINMENU
:BENCH TEST
Set the tachograph to a K-factor of 8000
(remember to note the original setting first), or
press delete and enter K factor required. The
display and the setting method will vary
according to the type of tachograph selected.
Select K-factor
:8000 Pul/km?
The speed will then go up to 40km/h. After 10
seconds (the time will count down to zero)
there will again be an audible beep. To move
on to the next test before the end of the
normal time press ENTER.
Speed: 40km/h
Time: 10 s
The speed will then go up to 80km/h. After 10
seconds (the time will count down to zero)
there will again be an audible beep. To move
on to the next test before the end of the
normal time press ENTER.
Speed: 80km/h
Time: 10 s
The speed will then go up to 180km/h. After
60 seconds (the time will count down to zero)
there will again be an audible beep. To move
on to the next test before the end of the
normal time press ENTER.
Speed: 180km/h
Time: 60 s
Set both duty knobs to Work, and press
ENTER on completion.
Driver=Work
Crew=Work
The unit will record duty time for 120 seconds
(the time will count down to zero). After that
time a beep is heard.
Recording duty
Time: 120 s
91
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
Set both duty knobs to Rest, and press
ENTER on completion.
Driver=Rest
Crew=Rest
The unit will record duty time for 120 seconds
(the time will count down to zero). After that
time a beep is heard.
Recording duty
Time: 120 s
Set both duty knobs to Passive, and press
ENTER on completion.
Driver=Passive
Crew=Passive
The unit will record duty time for 120 seconds
(the time will count down to zero). After that
time a beep is heard.
Recording duty
Time: 120 s
92
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
ANNEX C DTC
VR2400 SERIES TACHOGRAPH – DIAGNOSTIC TROUBLE CODES (DTC)
Description
Store
d
(Y/N)
Remarks
Suggested Action
A00C
Internal Error
Y
Internal device error.
Reset tachograph and re-test.
9010
LCD Error
Y
Fascia communications.
Check fascia functions (keypress,
display, etc.)
A400
Tachograph Power Supply
Y
Power interruption.
Check power supply and
connections.
9060
Drawer Error
Y
Drawer catch failure.
Check drawer function.
9061
Speed Rack Error
Y
Speed rack motor or opto failure.
Check charts inserted correctly.
Reset tachograph and re-test.
9062
Duty Rack Error
Y
Duty rack motor or opto failure.
Check charts inserted correctly.
Reset tachograph and retest
9063
Cam Error
Y
Cam motor or opto failure.
Check charts inserted correctly.
Reset tachograph and retest.
9064
Chart Table Error
Y
Chart table motor or opto failure.
Check charts inserted correctly.
Reset tachograph and retest.
A822
Sender-Tachograph Key/Serial Number
Mismatch
Y
Encrypted data errors.
Re-pair tachograph to Sender.
Check wiring to B-socket.
A423
Sender-Tachograph Communications
Problem
Y
Encrypted communications errors
(encrypted sender) or complimentary
signal failure (4 wire sender) or
sender disconnection.
Check tachograph settings – Sender
Type. Re-pair sender if necessary.
Check wiring to B-socket.
9430
V-pulse Output Error
Y
Monitoring of V-Pulse output.
Disconnect all V-pulse supported
equipment. Retest tachograph. If
DTC does not reappear, suspect Vpulse driven equipment.
900F
Keyboard Error
Y
Key jammed or held for excessive
period.
Check all keys/buttons on
tachograph. Retest tachograph.
A00E
Calibration Error
Y
Requires configuration
Check tachograph settings – Install
Date and Service Delay. Retest
tachograph. The service delay
applies to tachographs fitted with
battery backed clock only – DC,
Renault, MAN.
A050
Driving without Chart
N
Speed pulses detected with drawer
open, driver chart missing or chart
recording complete.
Ensure driver chart present and
drawer properly closed.
9051
No Driver Chart Present
N
Drawer closed with no driver chart
present.
Insert driver chart
9052
No Crew Chart Present
N
Drawer closed with no crew chart
present.
Insert crew chart if required.
93
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs
ANNEX D Character Map.
Under certain functions, various characters can be entered by continually pressing the numeric
keys on the programmer. The mapping for the characters against each key is listed below;
0!“#$%&'()
1 *+,-./:;
2ABCabc=>?
3DEFdef@[\
4GHIghI]^_
5 J K L j k l `{ |
6MNOmno}~
7PQRSpqrs
8TUVtuv
9W XYZwxyz<
ANNEX E -
Language codes for preferred language
Here is the list of the character codes for the preferred language that can be used in the MKII
programmer, each code is a 2 digit character that references to a language.
Code
Language
Code
Language
“en”
English
“it”
Italian
“sv”
Swedish
“Iv”
Latvian
“fr”
French
“It”
Lithuanian
“nl”
Dutch
“hu”
Hungarian
“de”
German
“mt”
Maltese(English)
“es”
Spanish
“pl”
Polish
“cs”
Czech
“pt”
Portuguese
“da”
Danish
“sk”
Slovakian
“et”
Estonian
“sl”
Slovenian
“el”
Greek
“fi”
Finnish
“ga”
Irish(English)
“no”
Norwegian
“is”
Icelandic
Please note that if an invalid code is entered e.g. “zk” then the language will be automatically set to
English.
94
Document No. 6957-193
June 2006 Revision 2.3
©Copyright Stoneridge Electronics Ltd
Manufacturers of VEEDER-ROOT Tachographs