Infinity Support System
Transcription
Infinity Support System
MAYFIELD ® Infinity Support System SET-UP The Infinity Support System attaches to any MAYFIELD® Base Unit to provide excellent head support, and greatly improves patient positioning for all patient age groups. With the patient’s head supported, the Infinity Support System creates a method for simultaneous application of a Skull Clamp (ages 5+). Ease of positioning is facilitated by independent lateral, vertical, and horizontal movement of the chosen Head Support. Slide Coupler onto Base Unit • Slide Coupler onto any MAYFIELD® 2 Base Unit with the Lock Knob facing the OR table (1). Keep the unit loose enough to easily move for positioning freedom (2). 3 MAYFIELD® Infinity Support System (A1112) Coupler • Secure the Base Unit into the OR 1 table, as usual (3). Place Desired Headrest into Coupler Ball Joint • Choose the desired Headrest (3 options) and place ball base firmly into the Coupler Ball Joint (1). 2 Headrests • Tighten Socket T-Knob to secure Headrest into Coupler, but allow for some movement for ease of positioning (2). 1 Position Infinity Support into Desired Location 4 • Lateral movement can be modified 2 3 MAYFIELD® Infinity Skull Clamp (A1114) by placement of the Coupler on the Base Unit (1). Position the Headrest as close as possible to the OR table for optimal support. • For vertical adjustments, wind the Gear Housing Knob up or down (2). • Horizontal adjustments can be made freely inside the width of the Base Unit Supports until the Lock Knob is tightened (3). • Secure Infinity Support System in the desired location (4). OPTIONAL SKULL CLAMP APPLICATION • After the patient is resting on the 1 Infinity Support, apply the MAYFIELD® Infinity Skull Clamp to the patient using normal practices. Connect the Skull Clamp to the Adaptor (1) and lock the Base Unit handle (2). • Curved arms designed for use with horseshoe. • Elongated arms for optimal placement. • Four rocker arm attachments and two pressure knobs available in system (18-lb Torque Screw not shown). 2 Refer to Instruction Manual for complete instructions. Final set-up is dependent upon surgeon preference. NS1515-08/07 United Kingdom +44 (0) 1 264 345 700 +44 (0) 1 264 363 782 (Fax) CustSvcUK@Integra-LS.com France +33 (0) 4 37 47 59 10 +33 (0) 4 37 47 59 29 (Fax) CustSvcFrance@Integra-LS.com Germany +49 (0) 800 1010 755 +49 (0) 2102 5536 636 (Fax) CustSvcGermany@Integra-LS.com Benelux +32 (0) 2 257 41 30 +32 (0) 2 253 24 66 (Fax) CustSvcBenelux@Integra-LS.com Switzerland +41 (0) 2 27 21 23 30 +41 (0) 2 27 21 23 32 (Fax) CustSvcSuisse@integra-ls.com The Integra wave logo is a trademark of Integra LifeSciences Corporation. MAYFIELD is a registered trademark of SM USA, Inc., and is used by Integra LifeSciences Corporation under license. All Rights Reserved. ©2007 Integra LifeSciences Corporation. Integra LifeSciences Corporation • 4900 Charlemar Drive, Bldg. A • Cincinnati, OH 45227 • Toll Free: 877-444-1114 • Phone: 513-533-7979 • Fax: 513-271-1915
Similar documents
MAYFIELD®
• Always refer to the appropriate instructions for use for complete clinical instructions.
More information