nacelle damage description - Taca International Airlines
Transcription
nacelle damage description - Taca International Airlines
ENGINEERING ORDER EO. No: A320PR54-029/13 R0 Rev. Date: 05/17/2013 Date: 05/17/2013 Pag 2 of 15 EFFECTIVITY: P/N AIRCRAFT MODEL / COMPONENT FAN COWL DOOR 745-4000-503 REFERENCES: S/N 5470001 REMARKS Currently installed on A/C N522TA - MSN 5219 COMPLIANCE /A/ TACA EO A320TR54-027/13 NONE /B/ TACA EO A320IN54-028/13 NONE /C/ RDAS: ROHR/S067/2013 Issue A PCW /D/ TACA Message: TAI-SAL-13-051713/000 NONE /E/ Message between Goodrich and TACA: Dated 20/09/2013 FCW DUE DATE: On or before the A/C reaches 1666 FC FORM QA-073/96 TS-F R0 ENGINEERING ORDER EO. No: Date: 05/17/2013 A320PR54-029/13 R0 Rev. Date: 05/17/2013 DISTRIBUTION LIST (Planning will distribute all copies) Pag 3 of 15 PUBLICATIONS AFFECTED Chapter Technical Records .............. Stockroom .............. Reliability .............. Line Maintenance .............. Hangar Maintenance .............. Flight Operations .............. Quality Control .............. Quality Assurance .............. Technical Publicactions .............. Warranty .............. Other .............. None Publications None X X Comments: None. SUPPORT DOCUMENTATION DOCUMENT NUMBER DOCUMENT TYPE TITLE 12-34-24 PB 201 AMM Aircraft Grounding 54-20-00 Repair 004 Goodrich SRM FAN COWL HONEYCOMB DENT REPAIR LABOR ESTIMATE: SKILLS: CREW: MAN-HRS: ELAPSED: STR 1 3 3 INS 1 1 0 2 4 3 TOTAL: FORM QA-073/96 TS-F R0 ENGINEERING ORDER EO. No: Date: 05/17/2013 A320PR54-029/13 R0 Rev. Date: 05/17/2013 Pag 4 of 15 PARTS AND MATERIALS (Per Unit) PART NUMBER DESCRIPTION QTY UNIT P.O./M.R. REMARKS 01428 LPS PRESOLVE 1 Gal Or alternative. Use as required WDC WHITE WIPE 8 Oz. use as required. BJO-0930 PHENOLIC MICROBALLON 1 Lbs Use as required 1635477 LIJA 240 3 EA Or alternative. Use as required 30002 MARKING PEN 1 EA Use as required EA934NA EPOXI RESIN QUART KIT 1 KIT Alternative PN CG-1305A/B can be used. Use as required. TOOLS PART NUMBER None DESCRIPTION QTY P.O. REMARKS None FORM QA-073/96 TS-F R0 ENGINEERING ORDER E.O. No: Rev. No: A320PR54-029/13 0 DATE: PAGE: 05/17/2013 5 of 15 SUBJECT: ATA 54 - FAN COWL - O/B FAN COWL DENTS - PERMANENT REPAIR FREQUENCY: TAIL: STATION: DATE: N/A MECHANIC Q.C. INSTRUCTIONS XXX XXX ACCOMPLISHMENT INSTRUCTIONS XXX XXX A. GENERAL NOTE: Obey all of the WARNINGS and CAUTIONS included in the referenced manuals and procedures. XXX XXX B. JOB SET-UP 1. Make sure that the aircraft is electrically grounded as per AMM Task 12-34-24 PB 201. XXX 2. Locate the O/B Fan Cowl Door installed on ENG #1. 3. Confirm the Fan Cowl data is P/N 745-4000-503 and S/N 5470001: YES NO NOTE: In case answer is no, contact planning department for further disposition. 4. Confirm the damage is according to ref. /D/. YES [ ] NO [ ] If YES, continue with the next step If NO, contact engineering department before further flight. XXX XXX C. REPAIR INSTRUCTIONS 1. Repair the dents separately by means of Goodrich SRM 54-20-00 Repair #4 “FAN COWL HONEYCOMB REPAIR” NOTE: Heat lamps are to be used in order to apply heat to the affected area when the curing of compound EA 934NA is to be performed, use a thermometer in order to keep track of the temperature. FORM QA-073/96-TS-F R0 ENGINEERING ORDER E.O. No: Rev. No: A320PR54-029/13 0 DATE: PAGE: 05/17/2013 6 of 15 SUBJECT: ATA 54 - FAN COWL - O/B FAN COWL DENTS - PERMANENT REPAIR FREQUENCY: TAIL: STATION: DATE: N/A MECHANIC Q.C. XXX XXX INSTRUCTIONS D. CLOSE-UP 1. Make sure that the work area is clean and clear of tools and materials. 2. Restore the aircraft to a normal operating condition. XXX XXX End of this E.O. XXX XXX The following step is for documentation purposes only and is not related to the actual tasks performed on the subject aircraft TECHNICAL RECORDS: Insert a copy of this Engineering Order in the records of the subject aircraft and component. Name: ______________________________ XXX XXX Title: _______________________________ Date: _______________________________ Signature: ___________________________ FORM QA-073/96-TS-F R0 A320PR54-029/13.R0 Ref. /C/ Page 07 of 15 A320PR54-029/13.R0 Ref. /D/ Page 08 of 15 Rohr, Inc., operating as Goodrich Aerostructures Group NACELLE DAMAGE DESCRIPTION AFTERMARKET TECHNICAL SERVICES ENGINEERING 850 Lagoon Drive, Chula Vista, CA 91910-2098 *DATE REQUIRED: 05/17/2013 REQUEST TYPE: CRITICAL REPAIR (Work Stoppage) AOG (2-4 Hrs) A/C LOCATION EL SALVADOR 05/17/2013 ROUTINE REPAIR A/C NEXT SCHEDULED FLIGHT GENERAL INFORMATION A/C TAIL REGISTRATION NUMBER N522TA Inaccurate or missing information can result in delays. Please forward all other information available (photo, etc.) to help provide a clear and complete damage description. Pictures may be inserted under the “Damage Description” section. For AOG Request, please contact the Goodrich Spares Sales Desk at (619) 691-2089 or sparesales@goodrich.com and a response will be provided within 2 to 4 hours after receipt of the complete damage. Important Note: All *RED highlighted blocks must contain an entry in order to process a repair request. CUSTOMER INFORMATION Maintenance Facilities Name: TACA AIRLINES Date: 05/17/2013 *Operator: TAI Location: EL SALVADOR C.A. Contact: Jorge Salinas Ref No.: TAI-SAL-13-051713/000 Tel: (503) 2366-7544 Fax: E-mail: jorge.salinas@aviancataca.com P.O. No. AIRCRAFT INFORMATION *Engine Type: V2500-A5 *Aircraft Type: A319-132 Engine S/N: N/A *Aircraft Registration: N522TA *Engine Position: POSITION #1 *Aircraft MSN: 5219 Engine Flight Hours: N/A *Aircraft Flight Hours: 2598 Engine Flight Cycles: N/A *Aircraft Flight Cycles: 1166 PARTS INFORMATION DESCRIPTION *A/C Component: *PART NUMBER 745-4000-503 *NAME *SERIAL NUMBER FAN COWL DOOR 5470001 Affected Part Affected Part Affected Part *SUMMARY During a routine inspection several dents were found on inboard fan cowl door outer skin of engine pos #1 as depicted in Figure 1. The damage dimensions are out of repair scope in accordance with SRM. *REPORT ANY PREVIOUS REPAIR IN THE DAMAGED AREA NONE. Rohr, Inc., a subsidiary of the Goodrich Corporation, operating as Goodrich Aerostructures Group FORM NO. E8210-4 A320PR54-029/13.R0 Ref. /D/ Page 09 of 15 Rohr, Inc., operating as Goodrich Aerostructures Group NACELLE DAMAGE DESCRIPTION AFTERMARKET TECHNICAL SERVICES ENGINEERING 850 Lagoon Drive, Chula Vista, CA 91910-2098 DAMAGE DESCRIPTION PAGE 2 OF 7 ENG POS #1 – FAN COWL DOOR (O/B) – OUTER SKIN – DENT DAMAGE REFERENCES: /A/ - Fan Cowl Door P/N 745-4000-503, S/N 5470001. DESCRIPTION: While performing a routine inspection on ref. /A/ several dents were found on outer skin. The damage consists in 6 (EA) dents shown in Figure 1. Refer to Figure 1 for location and details. TACA kindly proposes to leave those dents (as depicted in Figure 1) “as is” for a period of 500 FC with repetitive DVI inspection every 50 FC. ACTION: Based in the condition above described TACA kindly requests GOODRICH the following: 1. Please confirm if the proposal is acceptable as temporary repair for the damage conditions as depicted in Figure 1. 2. An answer within 4 hours would be highly appreciated. Best Regards. Rohr, Inc., a subsidiary of the Goodrich Corporation, operating as Goodrich Aerostructures Group FORM NO. E8210-4 A320PR54-029/13.R0 Ref. /D/ Page 10 of 15 Rohr, Inc., operating as Goodrich Aerostructures Group NACELLE DAMAGE DESCRIPTION AFTERMARKET TECHNICAL SERVICES ENGINEERING 850 Lagoon Drive, Chula Vista, CA 91910-2098 DAMAGE DESCRIPTION PAGE 3 OF 7 Figure 1 – Sheet 1/5 Rohr, Inc., a subsidiary of the Goodrich Corporation, operating as Goodrich Aerostructures Group FORM NO. E8210-4 A320PR54-029/13.R0 Ref. /D/ Page 11 of 15 Rohr, Inc., operating as Goodrich Aerostructures Group NACELLE DAMAGE DESCRIPTION AFTERMARKET TECHNICAL SERVICES ENGINEERING 850 Lagoon Drive, Chula Vista, CA 91910-2098 DAMAGE DESCRIPTION PAGE 4 OF 7 Figure 1 – Sheet 2/5 Rohr, Inc., a subsidiary of the Goodrich Corporation, operating as Goodrich Aerostructures Group FORM NO. E8210-4 A320PR54-029/13.R0 Ref. /D/ Page 12 of 15 Rohr, Inc., operating as Goodrich Aerostructures Group NACELLE DAMAGE DESCRIPTION AFTERMARKET TECHNICAL SERVICES ENGINEERING 850 Lagoon Drive, Chula Vista, CA 91910-2098 DAMAGE DESCRIPTION PAGE 5 OF 7 Figure 1 – Sheet 3/5 Rohr, Inc., a subsidiary of the Goodrich Corporation, operating as Goodrich Aerostructures Group FORM NO. E8210-4 A320PR54-029/13.R0 Ref. /D/ Page 13 of 15 Rohr, Inc., operating as Goodrich Aerostructures Group NACELLE DAMAGE DESCRIPTION AFTERMARKET TECHNICAL SERVICES ENGINEERING 850 Lagoon Drive, Chula Vista, CA 91910-2098 DAMAGE DESCRIPTION PAGE 6 OF 7 Figure 1 – Sheet 4/5 Rohr, Inc., a subsidiary of the Goodrich Corporation, operating as Goodrich Aerostructures Group FORM NO. E8210-4 A320PR54-029/13.R0 Ref. /D/ Page 14 of 15 Rohr, Inc., operating as Goodrich Aerostructures Group NACELLE DAMAGE DESCRIPTION AFTERMARKET TECHNICAL SERVICES ENGINEERING 850 Lagoon Drive, Chula Vista, CA 91910-2098 DAMAGE DESCRIPTION PAGE 7 OF 7 Figure 1 – Sheet 5/5 Rohr, Inc., a subsidiary of the Goodrich Corporation, operating as Goodrich Aerostructures Group FORM NO. E8210-4 A320PR54-029/13.R0 Ref. /E/ Page 15 of 15 Jorge Alberto Salinas Viaud From: Sent: To: Cc: Subject: Britton, Charlie UTAS <Charlie.Britton@utas.utc.com> Friday, September 20, 2013 12:22 PM Jorge Alberto Salinas Viaud Manzano, Juan UTAS RE: Curing Procedure EA 934NA Jorge, The most common way to heat the area is with the heat lamps. No problem. Charlie Britton – Airline Support Manager – Aerostructures UTC AEROSPACE SYSTEMS 850 Lagoon Drive, Chula Vista, CA 91910 USA Tel: 1 619 691 2836 Mobile: 1 619 917 2836 Fax: 1 619 498 7322 Charlie.britton@utas.utc.com www.utcaerospacesystems.com Subject to the EAR, ECCN [9E991]. This information is subject to the export control laws of the United States, specifically including the Export Administration Regulations (EAR), 15 C.F.R. Part 730 et seq. Transfer, retransfer, or disclosure of this data by any means to a non-U.S. person (individual or company), whether in the United States or abroad, without any required export license or other approval from the U.S. Government is prohibited. CONFIDENTIALITY WARNING: This message may contain proprietary and/or privileged information of UTC Aerospace Systems and its affiliated companies. If you are not the intended recipient please 1) do not disclose, copy, distribute or use this message or its contents, 2) advise the sender by return e-mail, and 3) delete all copies (including all attachments) from your computer. Your cooperation is greatly appreciated. From: Jorge Alberto Salinas Viaud [mailto:jorge.salinas@avianca.com] Sent: Friday, September 20, 2013 11:17 AM To: Britton, Charlie UTAS Cc: Manzano, Juan UTAS Subject: [External] Curing Procedure EA 934NA Importance: High Dear Charlie, Currently we are going to perform a repair on a Fan Cowl using the Goodrich SRM 54-20-00 Repair 04, within the instructions of this repair procedure it is allowed to use the material EA 934NA improving the curing time by adding heat (93 Celsius). Our concern is that in the SRM is not specified the procedure to achieve this temperature to the compound EA 934NA and in the specifications of the material is not included either. Could you be so kind to inform us if is allowed to use heat lamps with a thermometer (in order to keep track of the temperature) or if hot bonding is to be used? Thank you for your help, Jorge Salinas Support Engineer Aeropuerto Internacional de El Salvador +503 – 2366-7544 Jorge.salinas@avianca.com 1