HOT WATER
SYSTEMS
www.thermann.com.au
GAS STORAGE
HOT WATER SYSTEM
THE THERMANN 4* GAS HOT WATER HEATER CAN
SUIT ANY FAMILY TYPE. WITH AN ADJUSTABLE
THERMOSTAT FOR SAFETY AND EFFICIENCY
IT ALLOWS YOU TO BE IN CONTROL OF YOUR
OPERATING COSTS AND422
PERFORMANCE. THE
UNIT HAS A SMALL FOOTPRINT
WHICH MAKES
162
IT IDEAL FOR REPLACING
A 3* CHANGEOVER.
502
B
A
GAS
INLET
422
162
502
D
C
(219)
477
SPECIFICATIONS
B
Gas Tank
Selecting the right unit for you
A
Net Weight Empty (kg)
80
86
1400
1400
135NG = 23.5
170NG = 27
Relief Valve Pressure (kPA)
Gas Consumption (MJ/h)
135LPG = 22.5
2
104
119
First Hr Delivery
239
289
Dimensions (mm)
135L
170L
Height (A)
1600
1900
Hot Water Outlet (B)
1325
1620
Cold Water Inlet (C)
220
220
Gas Inlet (D)
300
300
Water Inlet/Outlet
Dual
Dual
3-4
4-5
No. People
AL
7
YEAR
IT Y
C
G UARA
N
Cylinder
Recovery rate @ 45oC rise (L/hr)
170L
AL
1
YEAR
IT Y
E
170
135L
TE
135
E
Capacity (litres)
QU
170L
QU
135L
TE
Measurements
G UARA
N
Parts and labour
ELECTRIC LARGE
HOT WATER SYSTEM
THERMANN ELECTRIC STORAGE HOT WATER UNITS
ARE AN INSULATED STORAGE VESSEL EFFICIENTLY
STORING HOT WATER, READY FOR USE, WHEN YOU
NEED IT. THE THERMANN RANGE OF ELECTRIC
WATER HEATERS OFFER SOLUTIONS IN EIGHT
DIFFERENT SIZES TO SUIT YOUR NEEDS.
B
25°
K
B
25°
A
A
C
C
K
D
D
E
E
SPECIFICATIONS
Electric Tank
Selecting the right unit for you
o
Measurements
80L
125L
160L
250L
315L
400L
Total Height (A)
925
1090
1315
1445
1745
1705
Total Diameter (B)
490
530
530
615
615
705
Outlet Height (C)
735
865
1120
1211
1531
1445
Inlet Height (D)
160
190
190
195
195
220
Electrical Entry (E)
85
100
100
105
105
130
o
o
o
o
72o
Element Angle (K)
55
Storage Capacity
o
55
55
72
88
130
161
259
321
415
Hot Water Delivery
80
125
160
250
315
400
Net Weight Empty
41
51
61
72
92
110
Element Sizes (kW)
3.6
3.6
3.6
3.6
1000
1000
1000
1.8, 3.6 2.4, 3.6
72
80L
125L
160L
Inlet/Outlet
Dual
Handed
Dual
Handed
Dual
Handed
No. People
(continuous)
2-3
3-4
3-5
0
0
1-3
250L
315L
400L
Inlet/Outlet
Dual
Handed
Dual
Handed
Dual
Handed
No. People
(continuous)
3-5
4-6
5-9
No. People
(off peak)
1-3
2-4
4-6
No. People
(off peak)
1000
Max Inlet Pressure
800
800
800
800
800
800
With an ECV (kPa)
650
650
650
650
650
650
AL
7
YEAR
IT Y
G UARA
N
Cylinder
QU
QU
Without an ECV (kPa)
AL
1
YEAR
IT Y
E
1000
TE
1000
TE
Pressure (kPa)
E
Relief Valve
G UARA
N
Parts and labour
3
ELECTRIC SMALL
HOT WATER SYSTEM
THERMANN SMALL ELECTRIC STORAGE HOT
WATER UNITS ALLOW YOU TO INSTALL
HOT WATER WHERE SPACE AND ACCESS IS
RESTRICTIVE. WITH ITS “V FIT” CONFIGURATION,
INLETS AND OUTLETS ARE CONFIGURED
FOR EASE OF INSTALLATION. AVAILABLE IN
‘APPLIANCE WHITE’ FOR A MORE AESTHETICALLY
PLEASING UNIT.
SPECIFICATIONS
Selecting the right unit for you
Total Height (A)
455
695
Total Diameter (B)
405
405
Outlet Height (C)
280
520
Inlet Height (D)
155
155
65
55°
Storage Capacity (litres)
31
53
Hot Water Delivery (litres)
25
50
Net Weight Empty (kg)
17
23
Element Size (kW)
2.4*, 3.6 2.4*, 3.6
Relief Valve
Pressure (kPa)
1000
1000
Max Inlet Pressure
Without an ECV (kPa)
800
800
With an ECV (kPa)
650
650
*2.4kW plug in only
4
Inlet/Outlet
Dual
Handed
Dual
Handed
No. People
(continuous)
1
1-2
No. People
(off peak)
0
0
AL
7
YEAR
IT Y
G UARA
N
Cylinder
QU
65
55°
50L
QU
Electrical Entry (E)
Element Angle (K)
25L
AL
1
YEAR
IT Y
E
50L
TE
25L
E
Measurements
TE
Electric Tank
G UARA
N
Parts and labour
CONTINUOUS FLOW 5*
HOT WATER SYSTEMS
THE THERMANN 5* GAS CONTINUOUS FLOW
SYSTEM HEATS WATER AS IT FLOWS THROUGH
A COILED PIPE AROUND A GAS BURNER, WHICH
MEANS YOU’LL NEVER RUN OUT OF HOT WATER.
350
350
165
165
8.812
1515
585
585
2525
Recess Box
Painted
8484
COLD INLETR1/2 /15
COLD WATER
WATER INLET
WATER INLET FILTER
INLET FILTER
GAS
SUPPLY INLET
GAS
SUPPLY
INLET R3/4 /20
CABLE
ENTRY POINT
CABLE
ENTRY POINT
65
60
WATER
HOTHOT
WATER
OUTLET
OUTLET
R1/2 /15
71
35
31
623
619
575
575
8
8
13
13
50505050
PRESSURE
RELIEF VALVE
PRESSURE
RELIEF VALVE
330
330
12
165
Kitchen
Controller
15
Bathroom/Ensuite
Controller
8
13
68
350
198
50 50
278
SPECIFICATIONS
585
575
623
Continuous Flow 5*
26L
Accessories
Code
Kitchen controller with 15m cable
9504157
Bathroom controller with 15m cable
9504158
Ensuite controller with 15m cable
9504159
Recess Box Gal
9504553
Measurements
16L
20L
Nominal hourly gas consumption
(MJ/h)
125
160
Test point pressure NG (kPa)
0.4
0.56
Test point pressure LPG (kPa)
0.4
0.61
0.7
Minimum water pressure (kPa)
260
260
210
Maximum water pressure (kPa)
1200
1200
1200
NG 1.13
LPG 2.75
NG 1.13
LPG 2.75
NG 1.13
LPG 2.75
NG 5.0
LPG 7.0
NG 5.0
LPG 7.0
NG 5.0
LPG 7.0
Minimum Flow Rate Ignition (l/min)
2.7
2.7
2.7
No. Bathrooms
Input voltage single phase 50Hz (v)
240
240
240
200
35
0.68
25
84
COLD WATER INLETR3/4 /20
Minimum gas inlet pressure (kPa)
Maximum gas inlet pressure (kPa)
9504555
HOT WATER OUTLET
R3/4 /20
GASBracket
SUPPLY INLET
Locking
9504554
R3/4 /20
PRESSURE RELIEF VALVE
330
Selecting the right unit for you
16L
20L
26L
1
1-2
2-3
Energy Rating (Stars)
5.2
5.3
5.8
Capacity @ 25° rise
(L/min)
16L
20L
26L
0.45
0.47
Inlet gas connection male thread
R3/4" (20mm)
R3/4” (20mm)
R3/4” (20mm)
Cold water connection male thread
R1/2" (15mm)
R1/2" (15mm)
R3/4" (20mm)
Capacity @ 40° rise
(L/min)
10
12.5
16.25
Hot water connection male thread
R1/2" (15mm)
R1/2" (15mm)
R3/4" (20mm)
Gas Type Available
NG, LPG
NG, LPG
NG, LPG
Relief valve pressure setting (kPa)
1400
1400
1400
16
16
17
575x350x165
575x350x165
575x350x165
SAIG Approval certificate no. GSCS20021. Watermark Certificate of compliance WMKA 00506
YEAR
IT Y
G UARA
N
AL
3
YEAR
IT Y
E
AL
TE
10
QU
Dimensions (HxWxDmm)
E
Weight dry (kg)
QU
0.42
TE
Maximum output current (A)
Recess Box Painted
WATER INLET FILTER
CABLE ENTRY POINT
G UARA
N
Heat Exchanger Parts and labour
5
CONTINUOUS FLOW 6*
HOT WATER SYSTEMS
15mm
12mm
546mm
546mm
25mm
15mm
200mm
584mm
520mm
68mm
Recess Box
Painted
68mm
68mm
39mm
39mm
200mm
12mm
12mm
68mm350mm
68mm
68mm
12mm
350mm
68mm
584mm
520mm
25mm
THE THERMANN 6*, ENERGY EFFICIENT GAS
CONTINUOUS FLOW UNIT ENSURES YOU WILL
HAVE ENOUGH HOT WATER, WHEN YOU NEED
IT. WITH A 12 YEAR WARRANTY, YOU CAN REST
ASSURED YOU ARE COVERED FOR THE LIFE
OF THE UNIT, AND UNIVERSAL CONTROLLERS
ENSURE YOU ALWAYS HAVE PRECISE CONTROL
OF YOUR HOT WATER TEMPERATURE SETTINGS.
68mm
COLD WATER INLET
R3/4 /20
POWER CABLE ENTRY
POWER CABLE ENTRY
REMOTE CONTROLLER
CABLE ENTRY
REMOTE CONTROLLER
WATER INLET FILTERCABLE ENTRY
PRESSURE RELIEF VALVE
HOT WATER OUTLET
R3/4 /20
HOT WATER OUTLET
R3/4 /20
PRESSURE RELIEF
VALVE
COLD WATER INLET
334mm
R3/4 /20
100mm
80mm
69mm
WATER INLET FILTER
GAS SUPPLY INLET
R3/4 /20
GAS SUPPLY INLET
R3/4 /20
SPECIFICATIONS
174mm
260mm
334mm
Continuous Flow 6*
Measurements
16L
20L
26L
Accessories
Code
Nominal hourly gas consumption by
proportional electronic gas control (MJ/h)
125
158
200
Universal controller with 15m cable
9505082
6* Recess Box Painted
9505219
6* Recess Box Gal
9505218
6* Locking Bracket
9504679
6* Flue Diverter
9505161
Test point pressure (Propane) (kPa)
0.91
1.4
1.5
Minimum water pressure (kPa)
60
90
110
Maximum water pressure (kPa)
1200
1200
1200
Minimum gas inlet pressure (kPa)
NG 1.13
LPG 2.75
NG 1.13
LPG 2.75
NG 1.13
LPG 2.75
Maximum gas inlet pressure (kPa)
NG 5.0
LPG 7.0
NG 5.0
LPG 7.0
NG 5.0
LPG 7.0
Minimum Flow Rate Ignition (l/min)
2.7
2.7
2.7
Input voltage single phase 50Hz (V)
240
240
240
Maximum output current (A)
0.39
0.45
0.46
Inlet gas connection male thread
R3/4" (20mm)
R3/4" (20mm)
R3/4" (20mm)
Cold water connection male thread
R3/4" (20mm)
R3/4" (20mm)
R3/4" (20mm)
Hot water connection male thread
R3/4" (20mm)
R3/4" (20mm)
R3/4" (20mm)
Relief valve pressure setting (kPa)
1400
1400
1400
15
15
16
520x350x200
520x350x200
520x350x200
Dimensions (HxWxDmm)
16L
20L
26L
No. Bathrooms
1
1-2
2-3
Energy Rating
(Stars) (50°C)
6.3
6.5
6.1
Energy Rating
(Stars) (60°C)
6.0
6.0
6.0
Capacity @ 25°
rise (L/min)
16L
20L
26L
Capacity @ 40°
rise (L/min)
10
12.5
16.25
NG, LPG
NG, LPG
NG, LPG
Gas Type Available
AL
YEAR
IT Y
G UARA
N
QU
12
QU
SAIG Approval certificate no. GSCS20021. Watermark Certificate of compliance WMKA 00506
Selecting the right unit for you
AL
3
YEAR
IT Y
E
0.8
TE
0.8
E
0.56
TE
Test point pressure (Natural Gas) (kPa)
Weight dry (kg)
6
Universal
Controller
46mm
G UARA
N
Heat Exchanger Parts and labour
EVACUATED TUBE SOLAR
ELECTRIC BOOSTED
THERMANN EVACUATED TUBE SOLAR
ELECTRIC BOOSTED SYSTEMS HARNESS
THE SUN’S ENERGY TO HEAT YOUR
WATER. AN ELECTRIC ELEMENT IN THE
TANK PROVIDES BACK UP IF NEEDED,
ENSURING PEACE OF MIND, WHILST
ALSO REDUCING YOUR RUNNING COSTS.
A
HW
Outlet
A
B
PTRV
Top Sensor
Solar
Return
B
Bottom
Sensor
Flow
Inlet
SPECIFICATIONS
Selecting the right unit for you
400L
BOT
400L
MID
Tank Diameter (A)
648
648
648
648
731
731
Tank Height (B)
1388
1388
1682
1682
1731
1731
HW Outlet
1167
1167
1470
1470
1474
1474
PTRV Port
1167
1167
1470
1470
1474
1474
Top Sensor Port
759
759
841
841
841
841
Solar Return Port
564
432
564
509
564
564
250L
315L
400L
No. People
3-5
4-6
5-9
No. Tubes
22
30
44
*Other kit configurations available
369
303
369
342
369
369
Solar Flow
174
174
174
174
174
174
Cold Water Inlet
74
74
74
74
74
74
Dry Weight (kg)
86
86
98
98
130
130
YEAR
IT Y
G UARA
Tubes
N
10
AL
YEAR
IT Y
G UARA
Tank
N
QU
Bottom Sensor
AL
QU
QU
15
AL
1
YEAR
IT Y
E
315L
MID
TE
315L
BOT
E
250L
MID
TE
250L
BOT
E
Measurements
(mm)
TE
Electric Boosted Tank
G UARA
N
Parts and Labour
Roof Collector
Measurements (mm)
Dry Weight
Collector
Width (A)
Length (B)
WO/Tubes
W/Tubes
22 Tubes
1636
2025
20kg
85kg
30 Tubes
2196
2025
24kg
112kg
Dry weights based on 3 track flush mount frame.
7
EVACUATED TUBE SOLAR
GAS BOOSTED
THERMANN EVACUATED TUBE SOLAR GAS
BOOSTED SYSTEMS OFFER RELIABILITY AND
EFFICIENCY. PASSIVE SUN TRACKING MEANS
MORE OF THE SUN’S RAYS ARE CONVERTED
TO USABLE HOT WATER THROUGHOUT THE
DAY - REDUCING YOUR POWER BILLS. WITH
THE GAS BOOSTED CONTINUOUS FLOW
UNIT, YOU’LL NEVER RUN OUT OF HOT
WATER, NO MATTER THE WEATHER.
A
HW
Outlet
A
PTRV
350
585
619
575
Bottom
Sensor
31
Flow
Inlet
84
25
SPECIFICATIONS
540
648
648
731
Tank Height (B)
1502
1389
1682
1721
HW Outlet
1300
1167
1470
1464
PTRV Port
1300
1167
1470
1464
Top Sensor Port
Tank Diameter (A)
1056
953
1196
1207
Solar Return Port
812
740
922
950
Bottom Sensor
497
457
548
562
160L
250L
315L
400L
No. People
1-2
3-5
4-6
5-9
No. Tubes
22
22
30
44
26L
26L
26L
26L
Gas Booster
Solar Flow
182
174
174
174
Cold Water Inlet
82
74
74
74
Dry Weight (kg)
61
86
98
130
For 26L Gas Continuous Flow specifications and warranty information refer to page 5.
Roof Collector
Measurements (mm)
Dry Weight
Collector
Width (A)
Length (B)
WO/Tubes
W/Tubes
22 Tubes
1636
2025
20kg
85kg
30 Tubes
2196
2025
24kg
112kg
Dry weights based on 3 track flush mount frame.
8
YEAR
IT Y
G UARA
Tubes
N
10
AL
YEAR
IT Y
G UARA
Tank
N
QU
AL
QU
QU
15
AL
1
YEAR
IT Y
E
400L GAS
TE
315L GAS
E
250L GAS
TE
160L GAS
E
Measurements (mm)
Selecting the right unit for you
TE
Gas Boosted Tank
15
8
165
Top Sensor
Solar
Return
B
8.8
5050
13
B
G UARA
N
Parts and Labour
STEP 1
H eat T rans f er
Heat Transfer
The sunlight strikes the dark absorber coating
inside the tube.
STEP 2
nd
es
e
ns
ed
liq
ui
d
Evacuated tube
absorbs sunlight
and converts to
usable heat
m
tto
r
o
st
ise
STEP 3
r
ur
po
Va
A circulator moves water from the storage
tank
pipe warming the water.
Ab sto
o rbthe
er C ocopper
ating
The solar heated water is then pushed down
into the storage tank for use. Anti-frost is built
Vacu u m Sp ace
in to the Thermann system to ensure solar hot
water can be provided even in cold regions.
uid
ns
ur
t
re
to
liq
en
nd
Co
d
se
p
to
bo
Absorber Coating
Vacuum Space
PASSIVE SUN TRACKING
Midday
Afternoon
The round tube design of the system passively
tracks the sun throughout the day giving
the highest possible performance from early
morning through to late afternoon.
Morning
ELECTRIC & GAS SETUPS
Electric Booster
Gas Booster
Thermann Solar Collector
Thermann Solar Collector
Thermann Solar Collector
Storage
Tank
Storage
Tank
Solar Return
Solar Return
Solar Return
Pump
Station
Pump
Station
Solar Flow
ris
to
m
The heat pipe
transfers the heat up to the
to
ot
b
coppert o header pipe location in the insulated
ns
p
box.
ur
t o manifold
et
Solar Flow
Co
HOW IT WORKS
Solar Flow
r
ou
EVACUATED TUBE SOLAR
Storage
Tank
Pump
Station
Hot water
to house
Gas
Booster Hot water
to house
Hot water
to house
Cold Inlet
Cold Inlet
Cold Inlet
Note: Diagram not to scale - basic system overview (not installation guide).
Note: Diagram not to scale - basic system overview (not installation guide).
Note: Diagram not to scale - basic system overview (not installation guide).
9
HEAT PUMP
HOT WATER SYSTEM
Heat output
30-60
670
1267
185
1267
18530°
16°12°
30-60
30-60
670
670
185
30-60
Heat Pump
670
30°
16°12°
SPECIFICATIONS
30°
16°12°
30°
16°12°
1267
1840
1840
1840
1638
1638
1638
1638
1840
MADE IN GERMANY, THE THERMANN HEAT PUMP
EXTRACTS HEAT FROM AMBIENT AIR AND QUIETLY
TRANSFERS IT TO HEAT WATER. IT COMES WITH A
REMOVABLE INTAKE GRILL FOR EASY CLEANING
AND SERVICING WHERE ACCESS IS LIMITED.
kW
Dimensions
Heat output at A15/W15-55
1.7
Capacity (litres)
300
Power consumption
kW
Relief valve pressure (kPa)
700
Consumption at A15/W15-55
0.5
Expansion control valve setting* (kPa)
550
Max Supply Pressure - without an ECV (kPa)
500
Sound data
dB(A)
Sound pressure level at 1m distance in a free field
56
Energy data
kWh
Standby energy consumption/24h at 65°C (Air 15°C)
1.14
Electrical details
Max Supply Pressure - with an ECV (kPa)
420
Minimum water pressure (kPa)
200
Dimensions
mm
Height of unit when tilted
1990
Fuses
C 10 A
Height (adjustable feet)
Rated voltage
240V
Diameter
670
Weights
kg
Weight (dry)
125
Weight (wet)
428
Connections
mm
Condensate drain
20
Water connection
RP3/4" (20mm)
Phases
1/N/PE
Frequency
50Hz
Rated current
2.5 A
Max. power consumption
700W
1870-1900
G UARA
N
Cylinder
10
YEAR
IT Y
Values
E
AL
2
TE
TE
YEAR
IT Y
QU
QU
AL
5
E
* ECV not supplied
G UARA
N
Parts and labour
Air flow rate
550 m3/h
Lower air temperature limit
0°C
Upper air temperature limit
42°C
HEAT PUMP
HOT WATER SYSTEM
HOW IT WORKS
1
4
2
AIR IN
(THERMAL ENERGY)
AIR OUT
HOT WATER OUTLET
3
COLD WATER INLET
1. A fan draws air through an evaporator. Thermal energy
within the air is transferred to a liquid refrigerant causing it
to change into a gas.
2. The refrigerant gas is then drawn into a compressor
which increases the pressure and as a result increases the
temperature.
3. A condenser (heat exchanger) then transports the hot
gas refrigerant around the outside of the water tank. This
heats the water inside the tank and the gaseous refrigerant
reverts into a liquid.
4. The pressure of the refrigerant is reduced as it goes
through an expansion valve and returns to the evaporator
for the process to start again.
11
www.thermann.com.au
Reece. Works for you.™
Call 1800 032 566 or visit www.reece.com.au for your nearest Reece store.
Due to limitations in the printing process the colours in this brochure are a guide only.
The manufacturer/distributor reserves the right to vary specifications or delete models from their range
without prior notification. The manufacturer/distributor takes no responsibility for printing errors.
All products enjoy a product replacement warranty. For full warranty details visit www.reece.com.au/productquality
V8 [BROCHURE CODE 2130530]