Protect your Power!
Transcription
Protect your Power!
divisional profile Protect your Power! Optimised Electronic Protection and Control Systems Electronic devices for optimised protection in power generation and distribution. When electrical systems stop working, everything comes to a halt. Wherever electricity keeps the economy running, the security of the power supply is essential for success. This is where the protection and control equipment from NEWAGE AVK SEG sets new standards. MODULAR SYSTEMS + INDIVIDUALISED CONSULTANCY = PRECISELY THE RIGHT SOLUTION With our wide range of products for protection and control applications in power generation and distribution, NEWAGE AVK SEG has built a unique reputation worldwide. Our modular-design product families provide customers with an array of solutions for perfect system protection. Due to our individualised style of consultancy, our customers find precisely the right product or system to meet their requirements. We develop specifically customised packages too. EXACTLY THE RIGHT PROTECTION SYSTEM FOR YOUR NEEDS. The customer always comes first. Because we want to offer the right solution for every situation, at NEWAGE AVK SEG you will find an extremely broad range of products to meet every possible requirement. Regardless of whether a protective appliance from our standard program or a complex custom-made protective system is required, at NEWAGE AVK SEG customers are given the solution to suit their individual needs. GENERATOR SET MANUFACTURERS: Whether genset control or supervision: NEWAGE AVK SEG has acquired an outstanding level of competence based on many years of experience in this field. Custom-made monitoring and protective devices always form part of our overall solutions. These range from the simple start and stop functions of a prime mover to highly complex power station management systems. ELECTRICAL UTILITY COMPANIES: Making the correct decisions requires fact-based information and NEWAGE AVK SEG can help you with professional mains studies and accurate network calculations. We offer special protection technology for ring main units. Decentralised power supplies such as wind power plants and conventional power stations benefit from the broad range of solutions for mains decoupling. SWITCHGEAR MANUFACTURERS: Original equipment manufacturers attach great importance to flexibility and cooperation in the development of particularly high value products. Therefore, we at NEWAGE AVK SEG provide you with custom-made solutions to cover all requirements. In addition, a range of good value devices from various product lines is also available. And for planning and forecasting, our combined protection and control systems offer plenty of scope for considerable savings. INDUSTRIAL CUSTOMERS: With development and production both under the same roof, at NEWAGE AVK SEG products improving the safety of power supply and distribution are produced quickly and without excessive bureaucracy. When retrofitting your industrial plants, you will come to appreciate the flexibility of our favourably priced solutions. Regardless of your location or requirements, the team of experts at NEWAGE AVK SEG will assist you in planning, support your project, and provide reliable backup at the time of commissioning. Sophisticated product lines – it is your choice SYSTEM LINE – The digital all-rounder Protection, Control, Supervision – are you looking for a complete solution for switchboards up to 132 kV instead of numerous individual units? SYSTEM LINE devices are variable protection and control systems with feeder, line and bus-bar protection. You can adjust all functions with ease and comfort. Where do you want to control it from? Local control via the separate operating unit CMP, a control input or remote control via the SCADA system. The devices take into account the panel and system interlocking functions. All operating or fault messages are given a time stamp with date and time. Protection? – All inclusive! • feeder protection with 18 protective functions • even with line differential protection, all backup protection functions are already on board Compact, universal, flexible Compact design of the protection and control system for • smallest low-voltage niches • all common switchboards on the market • wide range power supply and universal in- and outputs • current transformer inputs for both 1 A or 5 A • four different protective parameter sets • most commonly available MV switchgear Off to the new cell! • SYSTEM LINE SOFT for parameter setting and evaluation from a PC to the CSP or vice versa • copy complete parameter sets and single line diagrams by »Drag and Drop« with the relevant interlocking logic into your SYSTEM LINE unit Measuring, Evaluation, Diagnosis • SYSTEM LINE devices record electrical values such as current, voltage, power, etc. • numerous statistical and counting functions on a few »clicks« • high-performance fault analysis of the data recorded • valuable information for cost reduction within your company Standardised communication • process visualisation, station SCADA system, building automation or energy management • standardised interface via IEC870-5-103 or Profibus DP plus Modbus • step-by-step introduction into existing or planned electrical energy distribution systems Any further benefits required? • parameter setting occasionally via the operating unit of one panel • link the operating unit CMP to your notebook • internal bus for central evaluation of up to 16 devices HIGH TECH LINE – Safe, precise, well-proven KComplex protection functions are the special features of these devices for LV, MV and HV levels. The range of this well-proven, continuously developed line covers everything from basic overcurrent time protection via machine protection to high-quality differential protection. Arrangements as required Whether you wish to protect grids, generators, transformers or motors, the SEG-relays with their modular structure and thousand-fold applications will stand up to any task using individual or combination relays. HIGH TECH LINE the third generation with a high degree of perfection for applications like overcurrent time protection, mains decoupling and motor protection: • display of date and time • two parameter sets • disturbance recorder • fault value memory • free configuration of the output relays (matrix) • CB failure protection • display of primary values • triggering of the disturbance recorder by a digital input • Modbus RTU protocol Manifold additional functions • integrated into the relays for fault analysis and flexible adaptation to changing operating conditions • integrated communication interface to the SCADA system • SEG's additional software for parameter setting and fault analysis Fast fault detection If a protective function is triggered, the display level changes to the trigger level and shows the measured values at the moment of triggering which simplifies fault diagnosis. HIGH TECH LINE with its extensive protection functions, great number of additional functions, intuitive operation and 19"-compatible compact housing design, guarantees high-tech protection everywhere power is generated, converted or distributed. PROFESSIONAL LINE – The DIN-rail trendsetter in medium-voltage applications In this line you will find all common protective functions for LV and MV in individual or combination units. A special feature of the PROFESSIONAL LINE products is their attractive price due to their intelligent DIN bar design which is limited to essentials. Small but efficient – fast and safe • SMD technology with universal architecture for grid, generator and motor protection • micro-processor technology for top precision and reliability • complex measured value processing of the relays covers the effective values, real power measuring and communication capability in addition to characteristic lines Flexible adaptation • easily select rated voltages and rated frequencies • additional protective functions • great number of standard characteristic curves for individual application Universal supply • wide range power pack for operation with AC or DC voltage • to integrate the product into almost any operating environment Easy adjustment • DIP switches and potentiometers for quick and safe adjustment of protective functions and tripping values • adjustment via PC or notebook for this purpose • optional interface adapter plus appropriate software • active protection against alterations in the settings Compact design • standard DIN rail-mounted housings • fast installation at optimum costs • LV and MV practice-oriented terminals • suited for easy installation and easily accessible • first choice for everyone who is not obliged to use door installation With a variety of applications, SEG PROFESSIONAL LINE devices prove themselves in the most varied stationary applications – such as in type-tested energy supply systems – as well as in mobile applications: in construction site systems, container systems, in supply systems for trains, and in the most varied maritime applications, GL certified. SEG units fulfill the most stringent testing conditions, all requirements of IEC 60255 and are resistant to vibration and climate. WI LINE – Tripping without auxiliary voltage Customer-oriented design the protection relays in this line were developed in close cooperation with our customers. This cooperative development resulted in products which will match any circuit breaker commonly available in the market. As they work independent of auxiliary voltage, they are excellently suited for application in self-sustaining transfer, local grid and distribution stations as well as ring-main-units. Always live All products of the WI LINE are overcurrent time relays • two-step independent overcurrent time protection (DEFT) • dependent (INV) • specialist characteristic curves • integrated earth current protection as a further option Cleverly sourced • WI protection relays supplied from the measured current of the current transformers • low-energy tripping for all WI devices • integrated energy storage • operating mode independent of auxiliary voltage • solutions for standard transformer with 1 A or 5 A available For rough conditions For over 15 years more than 23,000 WI relays have been used and neither dirt, greatly fluctuating temperatures nor high humidity have had adverse effects on them. Did you know… ... that the WIP, flag ship of the WI LINE, offers additional functions? An optional, redundant voltage supply permits the following additional features, independent of whether a primary current is flowing: • display of up-to-date measuring values • earthfault protection (|E> 0.05 x |N) • free configuration of the output signals • communication via RS485 The communication interface allows online parameter setting with WI-Soft, reading of the fault value memory and connection to the SCADA system via the Modbus RTU Protocol. FUNCTION LINE – Plant automation All over the world SEG function and synchronising systems for automation of power generating systems secure the power supply and are used in a wide range of applications. SEG Auto Controllers compact, multi-functional and easy to use. AMF Controller Type NB2-1 • safe basis for emergency power systems • uninterrupted change back to mains operation after mains failure by additional synchronising unit • mains and generator supervision • speed, dynamo and battery voltage supervision AMF Controller NC3-1 • mains parallel operation in addition to the normal emergency power function • improved version of the basis unit NB2 • standard software for controlling synchronising procedures (overlapping operation) • relay matrix for configuring outputs operation and alarm • two-step load control Gen-set Controller NC3-2 • for all applications where mains supervision nor control of the mains CB is not required • for systems in prime power operation as gen-set controller in single sets and in systems where gen-sets are running in parallel • remote control of most functions • two-step load control Automatic controller NC3-3 for pump sets • has been specially designed for the control of pump sets • the pump set is started and stopped by the integrated mains supervision as well as by the level control Software NB2/NC3-Soft • diagnosis and setting software • adaption to different mains-generator configurations and system specific requirements • connection between PC/notebook (RS232 interface) and controller via cable with Sub-D plugs. Gen-set control system PCL1 For diesel- and gas engines with generator and mains circuit breaker control. Basic functions like NC3, but additionally equipped with • integrated generator protection • integrated synchronisation for uninterrupted switchover of the consumers, external operation of the circuit breakers • frequency and voltage control • counter for kWh, operating hours, maintenance request, gen-set starts • CAN-Bus interface for remote parameter setting and SCADA connection Gen-set control system PCM1 Basic functions like PCL1, however additionally equipped with • active power and power failure control during mains parallel operation • reactive and active power balancing of up to eight gen-sets among each other • automatic load management in accordance with availability and operating hours • event recorder with real-time clock • CAN-Bus interface for connection of up to 8 PCM1-M devices and SCADA system • second CAN-Bus interface for extension modules • minimum cost and time required for commissioning even with very complex power generation systems This high-end device is available in two versions PCM1-GG M: and PCM1-M PCM1-G For gen-set in isolated operation. Either a single gen-set or multiple systems in parallel operation. PCM1-M For mains standby and mains parallel operation of individual gen-sets and multiple sets in parallel. Software PCx/MPU-Soft • setting software • adaption to different mains-generator configurations and system specific requirements • interconnection between PC/notebook (RS232 interface) and controller via RJ45 and SUB-D plugs Multiple measuring converter MPU1-F • combined measuring, monitoring and data transmission device • measured values are recorded, processed, displayed and transferred • RS232 interface for parameter setting with PC • interface for communication: CAN-Bus or Modbus RTU (RS485) Multiple measuring converter with protection and control functions MPU2-S Functions like MPU1-F, but additionally equipped with • control, regulating, synchronising and protection functions • control system for frequency, voltage, active and reactive power, cos (ϕ) • integrated generator mains protection • event recorder with real-time clock • RS232 interface for parameter setting with PC • interfaces for communication: CAN-Bus or Modbus RTU (RS485) Synchronising system PSY Quick, safe and reliable for better availability. Variants of this system are available, so that all known synchronising applications can be covered • type PSY-F for automatic synchronisation of two gen-sets • a flush-mounting unit on a 19''-rack system including adjustable frequency balance • type PSY-FU for additional voltage balance necessary during synchronisation of gen-set with the mains • synchronising check relay SY/SP for additional security during manual synchronisation of generators • type PSY3-CB with external selection of CB operating times and max. frequency difference • type PSY3-N for secure release for connecting two synchronous voltage systems • type PSY2 for back panel mounting • alphanumerical display of the synchronising systems PSY3 showing all operating values and setting values BASIC LINE – A bargain buy The BASIC LINE supervision relays are the lowest-priced in the protection relay range. Even in this »Low-Cost« category, our relays are provided with micro-controllers and have a high quality housing for DIN-rail mounting with short-circuit-proof connection terminals (500 A/1 s). BU1-AC AC Voltage relay BF1 Frequency relay BV1 Phase sequence relay • application: voltage supervision of 1-phase or 3-phase systems • functions: undervoltage and overvoltage supervision • application: single phase frequency supervision • functions: underfrequency and overfrequency supervision • application: supervision of phase sequence and undervoltage in three or four wire systems BU1-DC2 AC Voltage relay BI1 Time overcurrent relay • application: voltage supervision of DC systems • functions: undervoltage and overvoltage supervision • application: three phase under- and overcurrent supervision BUA1 AC Voltage and voltage balance relay BZ1–P/G Speed relay • application: supervision of voltage unbalance in 3-phase systems, phase loss, phase sequence, undervoltage and overvoltage. Also available as BA1 without over-/undervoltage function • application: speed supervision of gensets via generator voltage or pick-up • functions: - 3 adjustable speed switchpoints - ignition speed - under- and overspeed BP1-R Directional power relay • application: detection of reverse power at gensets in parallel operation BN1 Mains decoupling relay • application: mains decoupling acc. to VDEW rules • functions: - over-/undervoltage - over-/underfrequency - phase sequence - vector surge supervision Visit us at newage-avkseg.com NEWAGE International Limited PO Box 17 Barnack Road Stamford, Lincolnshire PE9 2NB England Tel.: +44 (0)17 80 48 40 00 Fax: +44 (0)17 80 48 41 00 email: infostamford@newage-avkseg.com email: infomarkon@newage-avkseg.com AVK Deutschland GmbH & Co. KG Benzstraße 47– 49 63303 Dreieich Germany Tel.: +49 (0)61 03 50 39 0 Fax: +49 (0)61 03 50 39 40 email: infoavkdr@newage-avkseg.com SEG-Schaltanlagen-Elektronik-Geräte GmbH & Co. KG Krefelder Weg 47 47906 Kempen Germany Tel.: +49 (0)21 52 14 51 Fax: +49 (0)21 52 14 52 00 email: infoseg@newage-avkseg.com Please contact us for further information at: SEG-Schaltanlagen-Elektronik-Geräte GmbH & Co. KG Power Protection Division Krefelder Weg 47, 47906 Kempen Tel.: +49 (0) 21 52 1 45 2 08 Fax: +49 (0) 21 52 1 45 3 54 e-mail: electronics@newage-avkseg.com PM_PPDIV_03.03_03_GB