Central Fan Catalog
Transcription
Central Fan Catalog
CENTRAL W NE FAN CO. ST GE AR L D’S LAN G EN 3890 MYSTIC VALLEY PARKWAY, MEDFORD, MA 02155 PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 INDEX ITEM PAGE BLOWERS Double Inlet . . . . . . . . . . . . . . .47 Duct Blower . . . . . . . . . . . . . . .23 General Industrial — Material handling . . . . . .26, 27, 34, 35 General Purpose-utility . . . .28 thru 33 Pressure . . . . . . . . . . . . . . .27, 34 PVC-Corrosion Resistant . . .36, 37, 38 Supply or Make-Up (Roof Top) . . . .45 FANS ALL ITEMS SHOWN IN THIS CATALOG ARE CARRIED IN STOCK FOR IMMEDIATE DELIVERY MANUFACTURERS OF CENTRAL-AIRE ® Exhaust Fans FROM 8 TO 60 INCHES WITH SAFETY GUARDS STOCKING DISTRIBUTOR FOR ACME FANTECH PEERLESS BROAN FASCO TJERNLUND COOLAIR LAU VENT-AXIA DELHI NEW YORK AND OTHERS REPLACEMENT PARTS Fan Blades Electric Motors Blower Wheels Blower Shafts & Bearings Belts Pulleys Attic . . . . . . . . . . . . . . . . . . .11 Bathroom . . . . . . . .15, 16, 18, 19, 20 Ceiling . . . . . . . . . . . . . . . . . .20 Darkroom . . . . . . . . . . . . . . . .21 Duct-In Line . . .16, 17, 20, 22, 23, 24, 25 Exhaust, prop. . . . . . . . . . .4, 5, 6, 7 Kitchen . . . . . . . . .16, 18, 19, 42, 43 Roof, axial up-blast . . . .BACK COVER centrifugal up-blast . . . . .42, 43, 44 centrifugal . . . . . . . .16, 17, 40, 41 Sidewall, centrifugal . . . .16, 42, 43, 44 U.L., NFPA 96 APPROVED . . . . .42, 43 Window (Vent-Axia) . . . . . . . . . . .21 OTHER Chemical resistance data . . . . . . .38 Curbs, roof . . . . . . . . . . . . .40, 46 Darkroom (Vent-Axia) . . . . . . . . .21 Draft inducers, duct boosters . . .12, 13 Make-up air fans . . . . . . . . . .14, 45 Motor & fan controls . . . . . . . . . .10 Relief-Supply vents . . . . . . . . . . .46 Shutters & louvers . . . . . . . . . .8, 9 Static vents . . . . . . . . . . . . . .9, 46 Special Motors . . . . . . . . . . . .5, 10 Thermostats . . . . . . . . . . . . . . .10 Vibration Isolators . . . . . . . . . . .39 General Ventilation Info . . . . . . . . . .2 General Motor Info . . . . . . . . . . . . .3 Fans & Blowers Repaired CALL FOR PRICING. Wholesale, distributor and OEM discounts are quoted on request. TERMS: Net 30 Days We specialize in engineering practical solutions to all ventilating problems. Call direct to our engineering staff: Phone: (781) 393-4456 1-800-937-4326 Fax: (781) 396-4581 www.centralfan.com FREIGHT: F.O.B. Medford, MA GUARANTEE: ONE YEAR against defects in material or workmanship. We do not assume any responsibility for incidental or consequential damages. Details of terms and conditions; and limitations of warranty and liability available on request. ALL EQUIPMENT IS COMPLETELY ASSEMBLED AND TESTED BEFORE SHIPPING PRICE $3.00 CATALOG #37 GENERAL INFORMATION ASSUME: Air @ sea level (.075 lb/ft ), 70°F, 50% RH, 29.92 in. Hg. This is STP condition. 3 Volume varies directly New CFM = Old CFM x as speed: Horsepower varies as cube of speed: New HP = Old HP x Pressure varies as square of volume: New SP = Old SP x Horsepower varies as cube of volume: New HP = Old HP x 1750 to 3500 RPM = 8 x HP 1140 to 1750 RPM = 3.6 x HP 850 to 1140 RPM = 2.4 x HP RPM ( New Old RPM ) RPM ( New Old RPM ) CFM ( New Old CFM ) CFM ( New Old CFM ) 3 2 NOISE, SOUND RATINGS, & SONES 3 Typical Sound Levels Sones VENTILATION OF HOODS & BOOTHS Process Canopy Hoods Slotted Sides Steam Tanks Canopy Hood Threshold of feeling 110 15,000 CFM blower elevated train; chipping hammer, loud street noise 90 90* Noisy factory; highway auto 38 80 Shouting; noisy gathering 150–250 1500–2000 10 60 Average factory; Average restaurant 75–150 9 50 Average office 75–125 1 40 Quiet home: average auditorium Quiet conversation 30 Whisper 10 Sound proof room Threshold of human audibility 75–250 100–150 200–250 Paint Spraying Open Front Booth Furnaces Canopy Hood Enclosed Booth Laboratory Booth Source 500,000 CFM blower 120 Canopy Hood Island Hood Updraft Plating Tanks dB 140 150 Capture Velocity FPM Type of Hood Kitchen Ranges 100–200 150–250 Open Front Booth 75–125 0 KITCHEN RANGE HOODS 1. CFM required is length x width (in feet) x velocity as per above table. (Depth of hood does not enter into calculations) 2. Hood should extend approximately 12 inches beyond front and sides of range. Depth should be two feet or more to accommodate bursts of smoke. 3. Duct velocity can be 500 to 2000 FPM. 4. Two smaller ventilators are recommended in place of one for more flexible operation and also to provide ventilation should one fan fail. Recommended ventilators for kitchen range hoods are radial blade and backward curve blowers. 5. U.L. classification YZHW and NFPA 96 provide more detail. STATIC PRESSURE LOSSES (in. H2O) 10' .13 .31 .49 Duct Length 20' .17 .35 .53 30' .21 .39 .57 VEL. FPM 1800 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000 4200 VP In. Water .202 .249 .302 .359 .421 .489 .561 .638 .721 .808 .900 .998 1.10 VEL. FPM 4400 4600 4800 5000 5200 5400 5600 5800 6000 6200 6400 6600 6800 Recommended Ventilation Requirements Max. occupant Load, (persons per 1000ft.2) Classification Auditorium 150 Classroom 50 CFM per person or area Although fan noise is a function of a multitude of factors the principal sources are (a) air turbulence (b) mechanical and (c) vibration. Generally the quietest fan is also the most mechanically efficient. Because a given fan location characteristics dictate audible noise, fan dBA cannot be guaranteed. However, relative noise levels of fans can be suitable for considering one fan versus another. The SONE number used in this catalog is a mathematically derived loudness (sound pressure) value as heard by the human ear 5 feet from the inlet of the noise source in free air (no ducts). Under these conditions, 10 SONES is twice as loud as 5 SONES; or 20 SONES is 1/2 as loud as 40 SONES. Thus, SONE NUMBERS can be used as guides for fan selection. Where noise is a critical factor a more detailed, scientific analysis of the noise source and its surroundings would be desirable. However, lined ducts, especially near the fan, provide ample sound attenuation for most clean air situations. Also, to double the loudness (SONES) of a given fan, 13 more of the same fan must be added. Training Shops 15 15 0.5 cfm/ft.2 Locker Room Grease Filter 2" Mesh Baffle .25 .55 .25 .55 .25 .55 VP In. Water 1.21 1.32 1.44 1.56 1.69 1.82 1.96 2.10 2.24 2.40 2.72 2.72 2.88 Education *Max. permissible noise per 8 hr.-day No. of Elbows 0 1 2 VELOCITY PRESSURES (At Std. Density .075#/Ft.3) MOTOR RPM CHANGES & HP REQUIRED BASIC FAN LAWS 30 20 Lounge 100 30 Dining Room 70 15 Restaurant Offices Conference Room 50 20 Office Space 7 20 Reception 60 20 Public Spaces 0.5 cfm/ft.2 Locker Rooms Public Restrooms 75 cfm/closet or urinal Smoking Lounges 70 60 Specialty Shops 1.5/ft.2 Auto Service Stations Beauty Salons 25 25 0.30 cfm/ft.2 Clothing Stores 1.0 cfm/ft.2 Pet Shops Supermarkets 8 15 Sports & Facilities Ball Rooms 100 25 Gymnasiums 30 20 Ice Rinks 0.5 cfm/ft.2 Swimming Pools 0.5 cfm/ft.2 Workrooms ROOM SONES dBA CORRELATION Darkrooms 0.5 cfm/ft.2 Duplicating, Printing 0.5 cfm/ft.2 SUPPLY OR MAKE-UP AIR Unnecessary loss of summer air conditioning or winter heating can be avoided if 80-90% of exhaust air is supplied at or near the exhaust hood. Make-up air appropriately introduced into the exhaust hood need not be treated. 2 CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 Loudness, Sones Based on average duct velocity of 1700 FPM. CONVEYING VELOCITIES Material Sound Level dBA CATALOG #37 www.centralfan.com Air & Smoke Residential Public Buildings Industrial Kitchen Hood Fine Dry Dust Coarse Dust, Sawdust Large Particles, Moist Material PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 Duct Velocity FPM 500–1000 1100–1500 1500–2000 500–2500 2500–3500 3000–4500 4500 & Up MOTOR INFORMATION Central Fan Co. uses motors that comply with EPACT (see page 10) Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA). TYPE OF MOTOR USUALLY REQUIRED The great majority of small motors (1⁄2 HP & smaller) are 115 volts single phase. NEMA MOTOR FRAME DIMENSIONS-INCHES Sizes of 3⁄4 to 11⁄2 are fairly divided between 208/230 volts single phase and 208 to 550 volts 3 phase. Sizes of 2 HP and larger are generally three phase as they are less expensive and less troublesome than single phase motors. 1750 Frame Size* HP 3500 RPM 1750 RPM 1 ⁄20 ⁄12-1⁄3 1 ⁄2-11⁄2 1 ⁄8-1⁄2 3 ⁄4-2 D Shaft Height 3 42 48 56 1 U Shaft Dia. ⁄8 ⁄2 5 ⁄8 7 ⁄8 7 ⁄8 11⁄8 11⁄8 13⁄8 13⁄8 15⁄8 15⁄8 17⁄8 17⁄8 1 11⁄2 3 1 2 143T 145T 5 5-71⁄2 3 5 182T 184T 10 15 71⁄2 10 213T 215T 20 25 15 20 254T 256T 30 40 25 30 284T 286T V 2F Shaft Parallel Len. To Shaft 2E Across Shaft BA To First Bolt Hole 31⁄2 slot 41⁄4 slot 47⁄8 slot 21⁄16 21⁄2 23⁄4 25⁄8 3 31⁄2 11⁄8 11⁄2 17⁄8 13⁄4 23⁄4 3 31⁄2 31⁄2 21⁄4 21⁄4 4 5 51⁄2 51⁄2 21⁄4 21⁄4 41⁄2 41⁄2 23⁄4 23⁄4 41⁄2 51⁄2 71⁄2 71⁄2 23⁄4 23⁄4 51⁄4 51⁄4 33⁄8 33⁄8 51⁄2 7 81⁄2 81⁄2 31⁄2 31⁄2 61⁄4 61⁄4 4 4 81⁄4 10 10 10 41⁄4 41⁄4 7 7 41⁄2 41⁄2 91⁄2 11 11 11 43⁄4 43⁄4 Frames without ‘T’ (preceding smaller size shaft). *3500 RPM motors are smaller. APPROXIMATE MOTOR AMPS-1750 RPM * HP 1 ⁄6 1 ⁄4 1 ⁄3 1 ⁄2 3 ⁄4 1 Phase 115V 230V 200V 3 Phase 230V 460V 575V 3.0 4.0 5.2 7.0 1.5 2.0 2.6 3.5 .9 1.1 1.6 2.3 .8 1.0 1.4 2.0 .40 .50 .70 1.0 1 11⁄2 2 10.4 13.0 19.0 24.0 5.2 6.5 9.5 12.0 3.2 4.3 5.7 7.1 2.8 3.8 5.0 6.2 1.4 1.9 2.5 3.1 1.1 1.5 2.0 2.5 3 5 71⁄2 10 34.0 52.0 76.0 90.0 17.0 26.0 38.0 45.0 10.8 16.0 24.0 30.0 9.4 14.0 21.0 26.0 4.7 7.0 11.5 13.0 3.8 5.6 8.4 10.0 46.0 57.0 76.0 85.0 40.0 50.0 66.0 74.0 20.0 25.0 33.0 38.0 16.0 20.0 26.0 30.0 15 20 25 30 For 3600 RPM motors multiply by .90 For 1140 RPM motors multiply by 1.1 .32 .40 .56 .80 *60 Hertz Starting amps are approximately five times running amps. Fuses must be large enough to carry this current. Delayed action fuses of only 25% above rated current may be substituted for better protection. NEMA VOLTAGE VARIATIONS * Nameplate Rating EFFECT OF VOLTAGE IMBALANCE A small voltage imbalance between phases will cause an abnormal temperature rise and abnormal current. For example, temperature & current will rise 6-10 times the voltage difference. Notify the power company if voltage exceeds 1% (2 volts at 200v). PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 Suitable for line voltages 200/400 208,220 or 440 220/440 208,220,230 or 440,460 230/460 208,220,230,240 or 440,460,480 550 or 575 550 to 600 NEMA ratings are plus or minus 10% of nameplate. *60 Hertz Variations are suitable for fan or blower duty or other easy to start applications only. CATALOG #37 www.centralfan.com CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 3 CENTRAL-AIRE ® Model K Exhaust Fans HEAVY DUTY-GENERAL PURPOSE-DIRECT DRIVE-ENCLOSED MOTOR Quiet operating general purpose fans for ventilation of most small areas where the usual low pressure conditions exist. For long duct runs use a centrifugal blower. Suitable for use in restaurants, bars, clubs, laundries, bakeries, barns, stores, offices, industrial plants and electronic equipment cooling. Moderately priced and economical in operation-Built for years of dependable service-Broad deep pitch blades for quiet, high air delivery-Attractive design, Gray green finish. Quality is equal or superior to higher priced fans. • Thermally protected motors • Variable speed operation • Ball and sleeve bearings • Aluminum fan blades • OSHA type wire guards • 125°F max. temp. of operation General purpose exhaust fans for most small areas. Available with reverse air flow (suction type) at no extra charge. Suitable for operation to 125°F—Over 125°F use a centrifugal blower IMMEDIATE DELIVERY MODEL K-SINGLE PHASE-115 VOLTS• HP 1 Speed S Variable Speed Wall V Shutter 115 v. Amps Speed RPM 0 APPROXIMATE CFM Static Pressure (inches H2O) 1 1 3 .1 ⁄8 ⁄4 ⁄8 *K80 *K10 1/80 1/40 X X X X A8 A10 .6 1.0 1550 1550 300 600 220 500 190 450 100 300 — 210 *K12 *K14 1/20 X X X X A12 A14 1.4 2.1 1550 1100 1000 1500 920 1300 880 1200 700 1000 450 720 1/6 X X X —. A16 1860 1800 1560 1330 1/4 X X — — A18 2900 2660 2570 2340 2100 *KB20 1/4 X — A20 1160 1160 1160 1160 1160 2000 *K18 2.8 2.4 4.9 3.8 3.8 3600 3400 3330 3000 2700 *KB24 1/2 X — A24 6.5 1160 5800 5500 5200 4600 3700 *K16 *KB16 *KB18 1/15 *115/208-230v 1Ø (Ball Bearing) (v) Variable speed includes Solid State Control (X) Available Model K12 K14 16 18 71/2 8 K16 KB16 20 20 K18 KB18 3/4 15 17 14 16 11 13 1 1 19 19 18 18 22 22 105/8 13 1 1 21 21 20 20 KB20 24 13 1 23 22 KB24 30 13 11/2 27 26 3/4 ⁄8 Ship Wt. 7 12 15 20 28 30 29 32 35 51 •See p.5 for 3Ø Exhaust fans Exhaust Air Flow Reverse (suction) air flow requires motorized shutter with #C10 switch See page 8 *Fan and shutter mount over the hole **Add 2" for suction fan configuration 4 5 For mounting fan in opening larger than fan panel. Price includes mounting fan and shutter on plywood (3⁄4" outdoor type) of required size painted green. Models K12K24 require next size shutter. Dimensions (inches) Shutter Min. Hole B** C D Round* 5 0 111/4 8 51/2 0 13 10 A 101/2 13 ⁄2 MODEL K FAN AND SHUTTER ON PLYWOOD ACCESSORIES: Motorized shutter Chemical resistant coating fan Chemical resistant coating shutter Model No. K8 K10 1 See Page 5 For Fans In This Static Pressure Range Model No. CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 CATALOG #37 www.centralfan.com PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 CENTRAL-AIRE ® Model P Exhaust Fans SPECIAL PURPOSE—DIRECT DRIVE—HIGH PERFORMANCE Features include extra high outputs at higher static pressures, larger sizes, 3 phase and explosion proof motors. • • • • • • Sturdy construction for years of heavy duty service Fans may be mounted in any position Available with plywood panels for easy window installation Open drip proof Ball Bearing motors-1 & 2 Speed Totally enclosed Ball Bearing motors-1 & 2 Speed Explosion proof fans include non-sparking blade and Class I Group D, Class II Group F and G motors (See below “caution”) Explosion proof motors are single speed only All fans available with reverse air flow (suction type). Suitable for use to 125°F-Over 125°F use a centrifugal blower. For applications with special requirements SINGLE PHASE: 115 VOLTS‡ Model No. P10 P12 P14 P16A P16B P18A P18B P20A P20B P24A P24B P24C P30B HP 1 ⁄25 1 ⁄6 1 ⁄4 1 ⁄8 1 ⁄3 1 ⁄6 1 ⁄2 1 ⁄4 3 ⁄4 1 ⁄2 1 ⁄2 3 ⁄4 11⁄2 Fan with safety guard. 3 PHASE: 208, 230, 460 VOLTS With Open Motor With Enclosed Motor Expl. Proof* 1 Phase‡ 3 Phase 1 Phase 3 Phase 1 Phase 3 Phase 1 Speed 2 Speed 1 Speed 1 Speed 2 Speed 1 Speed 1 Speed 1 Speed S M T‡ S M T‡ SX TX CFM Static Pressure (inches water) RPM 0 1 1 ⁄8 ⁄4 5 ⁄2 — X X(v) — — — 1500 800 X X X X X X X X 1750 1470 1350 1200 900 –0 –0 X X X X X X X X 1750 2300 2100 1950 1600 1500 1400 X X — X X X X X — X — X X X — X 1140 1750 2000 3150 1800 3050 1500 2800 1100 2600 800 2300 –0 2000 X X — X X X X X — X — X X X — X 1140 1750 2900 4300 2600 4000 2200 3800 1700 3400 1500 3100 1300 2800 X X — X X X X X — — — X X X X X 1140 1750 3600 6000 3300 5800 3000 5600 2700 5300 2400 5000 2000 4700 X X X — X — — X X X X X — — — — X X — X — — X — 800 1140 1140 4800 6000 8000 4600 5800 6900 3900 5500 6200 2900 4500 5700 1800 3800 5500 1000 3400 5000 — — X — — X — — 1140 11000 10500 10000 9500 9000 8100 Caution: Explosion Proof motors and non-sparking blades are usually required in operating environments where explosive or ignitable gases or dust are present. Proper motor selection requires full understanding of U.L. and N.E.C. code designations. Article 500 (N.E.C.) covers the requirements for electrical equipment and wiring. Equipment selection and wiring is a customer (user) responsibility. Motors and impellers misapplied in hazardous environments are dangerous to personnel and property. Examples of some hazardous materials: Class I (Gases, Vapors) Group AAcetylene. Group BButadiene, ethylene oxide, hydrogen, propylene oxide. Group CAcetaldehyde, cyclopropane, diethyl ether, ethylene, isoprene. Group DAcetone, acrylonitrile, ammonia, benzene, butane, ethylene dichloride, gasoline, hexane, methane, methanol, naphtha, propane, propylene, styrene, toluene, vinyl acetate, vinyl chloride, xylene. Note: A motor rated for Class I, Group D should not be used in the presence of Group A,B or C substances; and a Class II, Group F & G motor should not be used with Group E substances. 300 –0 (X) Available Model Accessories: Model No. P10 P12 P14 P16 P18 P20 P24 P30 Wall Inlet Chem. Res. Shutter Guard Coating* X X X X X X X X X X X X X X X X X X X X X X X X *Fan only. See page 8 for shutter coating. D Opening Nec. (Round) Approx. Wt. (Lbs.) 1 1 13 15 17 19 10 14 16 18 25 30 35 45 11⁄2 11⁄2 11⁄2 2 21 23 27 33 20 22 26 32 50 60 80 110 Dimensions (inches) Class II (Combustibles Dusts) Group EAluminum, magnesium and other metal dusts with similar characteristics. Group FCarbon black, coke or coal dust. Group GFlour, starch or grain dust. Additionally, all hazardous location motors carry a “T code” which identifies the maximum motor surface temp. (operating and burnout) which must be correlated with the “minimum ignition temp.” of the hazardous substance. PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 400 ⁄8 X(v) (v) Variable speed includes solid state control 480 1 ⁄8 X ‡ See Pg.10 for 2 speed 3Ø, 208 1Ø and switches *Incl. Non-sparking blade 700 3 Model No. A B C P10 P12 P14 P16 13 16 18 20 10 11 12 13 0 P18 P20 P24 P30 22 24 30 36 13 13 14 15 ⁄4 3 Model number indicates fan blade diameter. CATALOG #37 www.centralfan.com CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 5 CENTRAL-AIRE ® Model R Exhaust Fans ALL PURPOSE—BELT DRIVE—RUGGED WELDED CONSTRUCTION All Purpose-Belt Drive-Rugged Welded Construction An all purpose high performance fan suitable for ventilation of most large areas requiring dependable ventilation. Large selection of speeds and motors to choose from to cover a wide range of commercial and industrial requirements. Recommended for ventilation of stores, halls, offices, restaurants, garages, barns, air conditioning equipment rooms and all types of industrial buildings. Moderately priced yet built for years of dependable service. WARNING: OSHA guards recommended when installing fan within 7' of floor. SEE page 7 IMPORTANT FEATURES • • • • • • • All purpose exhaust fans for most large areas. SPECIFY EXHAUST OR SUCTION Quiet operation-High air output-Slow speed. Flexible choice of speeds and motors available. Easy and economical motor replacement if necessary. Ball Bearing throughout-motor & fan. Generously sized belt drive for trouble free operation. Heavy duty propellers, designed for low static and high air volume…either exhaust or suction. Not designed for motor reversing operations. WITH OPEN MOTOR-WHEN ORDERING: SPECIFY LINE VOLTAGE AND PHASE Model R24 R30 R36 B C* D E F C D* E F G D E* F G H Single Phase** Three Phase Approx. Tip 1 Speed 2 Speed 1 Speed 2 Speed Wall Fan Speed Noise S M T R Shutter RPM FPM Rating HP 1 ⁄4 1 ⁄3 1 ⁄2 3 ⁄4 1 1 ⁄3 1 ⁄2 3 ⁄4 1 11⁄2 1 ⁄2 ⁄4 3 1 11⁄2 2 3 ⁄4 X X X X X X X X X X X X X X X – – X X X X X X X X X X X X – X X X X X – X X X X X X X X X X X X – – X X X X X X X X X X X X – – – X X X X X X X X X X R42 E F* G H J 1 11⁄2 2 3 X X X X X R48 F G* H J K 1 11⁄2 2 3 5 X X X X – X – – – – X X X X X X X X X X R54 G H* J K 11⁄2 2 3 5 X X X – – – – – X X X X X X X X R60 H J* K L 2 3 5 71⁄2 X X – – – – – – X X X X X X X X *Recommended for most commercial and industrial applications. See page 10 for special motors. (X) Available models **Single Phase 120v or 230v. See p.10 for 208v 1Ø. CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 0 1 ⁄8 1 ⁄4 3 1 ⁄8 5 ⁄2 ⁄8 540 600 690 750 850 3390 3770 4335 4710 5300 A A B C D 4800 5300 6000 7000 8000 3900 4600 5400 6400 7500 3100 4300 5600 6800 2800 3800 5400 3100 4300 3600 460 480 530 570 640 3770 4080 4710 5100 5890 A A B C D 7000 8000 9000 10000 12000 5700 6900 8100 9200 11300 4600 6500 8000 10300 4200 5400 8200 4400 6500 5300 480 600 620 700 760 3770 4712 5655 6597 7540 A B B C D 10000 12000 14000 16000 18000 8200 10300 12600 14700 17000 6900 10100 6400 12800 8600 15500 12200 7100 9800 7900 A42 400 480 520 600 670 3848 4398 5497 6322 7147 A B B C D 16000 18000 20000 22000 25000 13100 15400 18000 20200 23500 10400 14400 9200 17600 11900 9700 21500 17000 13500 11000 A48 400 460 500 580 650 3770 4712 5684 6597 8167 A B B C D 21000 24000 26000 30000 36000 17200 20600 23400 27600 33800 13900 16200 13200 24000 16200 13200 30900 24500 19500 16000 A54 300 350 420 500 4241 4948 5655 6361 A B B C 27000 30000 35000 42000 23200 27000 32200 39500 15600 21600 13800 28000 18900 15400 36000 28500 22000 18500 A60 270 300 375 470 4271 4712 5890 6744 A B B C 34000 41000 48000 55000 30600 37000 45000 53000 24500 32800 41000 49000 A24 A30 A36 See page 10 for motor controls. 18600 22100 18000 34000 27000 22000 44000 38000 33000 NOISE RATING Applications Dimensions & Accessories: See next page 6 CFM Static Pressure (inches water) CATALOG #37 www.centralfan.com Residences, Churches, Schools, Libraries Stores, Offices, Hall, Restaurants Laundries, Bakeries, Bowling Alleys Very noisy locations PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 Rating A A or B B or C B,C, D CENTRAL-AIRE ® Model R Exhaust Fans DIMENSIONS (INCHES) Panel Approx. Sq. Depth A B* Model No. C Shutter Opening Min. (Sq.) Req. (Rd.) Wall D O* W** Approx. Wt. Lb. 24 30 36 42 30 36 42 48 14 15 16 17 11⁄2 2 21⁄4 21⁄2 27 33 39 45 26 32 38 44 6 7 8 10 70-100 90-120 100-140 130-150 R 48 R 54 R 60 54 60 66 18 27 27 21⁄4 2 2 51 57 63 50 56 62 12 14 16 160-200 270-320 390-470 R R R R Model number indicates fan blade diameter. *Allows venturi penetration of wall. **Shutter blades will flutter if fan blade is too close to shutter. “W” dimension must be increased for higher RPM or where quieter operation is desired. OSHA COMPLIANT FAN GUARD 20 gauge galvanized steel panels, expanded metal grille. Bolt together guards shipped unassembled (mounting hardware included). Heavy gauge panels bolt together to form housing. Grille fastens to housing with screws supplied. Guard can be mounted directly to fan frame or wall. GUARD DIMENSIONS A B Depth C Ship Wt. 24 30 36 42 30 36 42 48 30 36 42 48 20 20 30 30 35 40 60 90 R 48 R 54 R 60 54 60 66 54 60 66 32 34 37 120 200 256 Model No. R R R R ACCESSORIES Model R R R R # * ** Inlet Guard Motorized Shutters 115 or 230 V #440V Chem. Resis. Coating Fan and Automatic Motor Shutter Motor* Two** Disconnect Speed Switch Controls 24 30 36 42 X X X X X X X X X X X X X X X X X X X X X X X X X X X X R 48 R 54 R 60 X X X X X X X X X X X X X X X X X X X X X 440V uses 115/230V motor with a transformer. Mounted to fan panel. All without overload protection (limited availability for larger HP’s see page 10). PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 CATALOG #37 www.centralfan.com CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 7 Model A Aluminum Wall Shutters AUTOMATIC-MOTORIZED-CHAIN OPERATED EXTRA HEAVY DUTY FRAMES FOR DIMENSIONAL STABILITY Model A Model No. • Frame is .080 x 1.50 extruded aluminum with mill finish & welded corners. • Aluminum blades are 26 gauge with 20 gauge galvanized reinforcement strip across top of blade & felt seal on leading edge of blade for quiet closing. • Stainless steel bearings and pivot pins for extended life. • POSITIVE ACTION MOTORIZED SHUTTERS: Motor is securely bolted to frame. Special linkage operates center rod for uniform and positive operation. • CHAIN OPERATED: For manual operation; coil spring positive closing. Nominal Dim. (Sq.) I.D. O.D. A B 2600 FPM Max CFM Automatic Motorized** Gravity 115 or Operated 230 V. 440 ≠ Model A Motorized Chain Operated A A A A 8* 10 12 14 8 10 12 14 11 13 15 17 1150 1800 2600 3500 X X X X –. X X X –. X X X X X X X A A A A A 16 18 20 24 30 16 18 20 24 30 19 21 23 27 33 4600 5850 7200 10400 16250 X X X X X X X X X X X X X X X X X X X X A A A A A 36 42 48 54 60 36 42 48 54 60 39 45 51 57 63 23400 31850 41600 52650 65000 X X X X X X X X X X X X X X X X X X X X SIDE VIEW AIR FLOW FRONT VIEW 5 *Steel frame with 1 ⁄8 flange….this size only **Also available as power close, fail open (for elevator machine rooms). Maximum UPS ship size is A36, B36 ≠ 440V uses 115/230V motor with a transformer (X) Available models Also available DELAY SWITCH….MOUNTED ON SHUTTER PROTECTIVE COATING Motorized shutter will not open against substantial fan induced air flow. Delay switch should be used to allow shutter to open fully before fan becomes operational. For 1Ø or 3Ø applications. Delay Switch Model C10 Air Dry PVC Coating . Models A,B or BS Model B Roof Fan Shutters Flange-less steel frame-Felted aluminum blades-Can be used inside ducts. Opens in direction of air flow. Curb drop in type to prevent backdraft when roof fan is not running. Sized to fit onto shelf of roof curb. Model No. Nominal To 1500 O.D. FPM Automatic +0 - 1⁄8 Max. Gravity (Square) CFM Operated B B B B B 9 10 12 14 15 9 10 12 14 15 800 900 1300 1800 2100 X X X X X X X X X X X X X X X B B B B B B 16 18 20 22 24 28 16 18 20 22 24 28 2400 3100 3900 4800 5700 7800 X X X X X X X X X X X X X X X X X X B B B B B 30 32 36 39 42 30 32 36 39 42 9000 10000 13000 15000 17900 X X X X X X X X X X X X X X X 20 24 28 321⁄2 391⁄2 3100 4800 7000 9000 14000 X X X X X – – – – – – – – – – BS BS BS BS BS 18 22 26 30 37 (X) Available models 8 CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 Motorized 115 or #440V 230 V. CATALOG #37 www.centralfan.com #440V use 115/230V motor with a transformer PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 STATIONARY LOUVERS • Extruded .081 aluminum alloy construction. • Drainable blades-Falling water is drained to the side, removing cascading water droplets from the air stream. • Mitered corners for dimensional stability. • Expanded 1⁄2" screen interior mounted. (insect screen optional) • 11⁄2" flange is standard (channel frame optional). • Standard mill finish (optional Baked Enamel, Kynar, Anodized). • 4" deep frame (6" Available). IN STOCK SIZES Stock No. S61 Nominal Size* (in.) 12 x 12 Free Area (ft2) 0.23 Intake CFM** 250 Ship Wt. Lbs. 9 S62 14 x 14 0.38 400 10 S63 16 x 16 0.53 570 12 S64 18 x 18 0.78 850 14 S66 24 x 24 1.64 1750 21 S67 30 x 30 2.81 3000 29 S68 36 x 36 4.31 4600 40 *Suggested hole size (Louver dimension **max. cfm before w/o flange 1⁄4" less) Max. single section 96" x 96". For larger sizes use multiple sections. Other sizes and shapes, etc. Special Order water penetration begins (1075 FPM). CUSTOM ORDER LOUVERS AND DAMPERS COMBINATION LOUVERS • Combination louvers integrate stationary blade and adjustable blade construction in a single frame. • All the features and options of stationary models. • Blade edge gaskets. BACKDRAFT DAMPERS • .064 aluminum construction. • Nylon bearings with Delrin pivot pins. • PVC foam gasketed blades. • Full 90 degree operation. • Rear mounted exposed linkage. • Flange and channel models available. • Wide variety of manual, electric or pneumatic operators. • Custom made to order maximum single size is 72" W x 96" H. For larger sizes use multiple sections. • Intake and exhaust installations. • Vertical and horizontal models. • Custom made to order maximum single size is 36" W x 72" H. For larger sizes use multiple sections. CONTROL DAMPERS • Available in 13 ga. aluminum and 16 ga. steel construction. • Opposed blade and Parallel blade models. • PVC foam gasketed blades. • Low leakage models with stainless steel jam seals. • Concealed end linkage. • Wide variety of manual, electric or pneumatic operators and operator accessories. • Custom made to order. PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 CATALOG #37 www.centralfan.com CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 9 Motor Controls for Fans & Blowers SINGLE SPEED CONTROLS Manual Type Cat. No. Phase Dimensions Nema Size Poles Fig. H W D Without Overload 6810-G 7810-GD 1 3 2 – 2 71⁄2 – 10 1 1 2 3 A A 4 4 21⁄4 21⁄4 21⁄2 21⁄2 Exp. Prf. 6810-E 1 1 2 – 00 1 B 63⁄4 31⁄2 43⁄4 B 3 1 43⁄4 Exp. Prf. Fig. A Maximum HP 208 460 115V 230 550 3 7810-E 1 7 ⁄2 – 10 00 3 6 ⁄4 3 ⁄2 TWO SPEED CONTROLS Without Overload Protection 27956 2512KG22 C61 C62 27940 3 (2 Wdg.) 3 (2 Wdg.) 1 1 1 1/3 3/4 1 1/2 7 1/2 1/3 3/4 1 10 - 00 1 00 00 00 3 3 1 2 2 C A C C C 4 1/4 4 1/4 4 1/4 4 1/4 4 1/4 2 1/8 4 5/8 2 1/8 2 1/8 2 3/4 2 3/8 2 3/8 2 2 3/8 2 1/2 JV2 JV5 3 (1 Wdg.) 3 (1 Wdg.) - 3 5 3 5 1 1 3 3 D D 8 8 3 3 3 1/2 3 1/2 SOLID STATE VARIABLE CONTROL LINE VOLTAGE THERMOSTATS (1Ø) Fig. B Max HP Max Motor Amps Temp ºF 115V 230V 115V 230V Range Diff Model Type C73 C74 C74A C76A C77* Heat/Cooling Cooling (Attic) Cooling (Attic) Heat/Cooling Heat/Cooling 3 ⁄4 3 ⁄4 – 3 ⁄4 – 11⁄2 11⁄2 – 11⁄2 – 13.8 13.8 4.4 13.8 16 10 10 – 10 8 50-90 90-130 50-120 40-110 30-110 Switch Type 2° SPST 15° SPST 15° SPST 3° SPDT 3° SPDT/SPDT (Shaded Pole or Perm. Cap. Motors) SINGLE PHASE Model No. C64 C65 C75 277V C64-3 C65-3 *2-stage (2speed or 2 motors). Fig. C MOTOR DISCONNECT SWITCHES HP 3 ⁄4 1-2 3 5 71⁄2-10 Fig. D * Single Phase 1 Sp. 2 Sp. X X X X X – – – – – 460V-550V only Three Phase 1 Sp. 2 Sp. X X X X X X X X X* – ( Volts Amps 120 6 120 10 230 6 277 6 3-wire control for constant 115v INPUT POWER SAVING (RPM CONTROL) A significant reduction in energy consumption is realized when centrifugal fan speeds are reduced only slightly. In applications where maximum demand volume is not constant (VAV Systems), RPM control with inverters (variable frequency) could result in considerable reduction in power consumption. (Fan power demand varies with RPM3) Analysis of each fan application will determine the suitability of various volume control methods (Dampers, inlet vanes & inverters). Inverters available special order. (X) Available The Energy Policy Act (EPAct) took effect October 24, 1997. This law mandates efficiency standards for general purpose, three phase, 2,4 and 6 pole AC motors from 1 to 200 horsepower manufactured for sale in the U.S. Many motors such as explosion proof, two speed, TEFC, single phase and others, are excluded. Central Fan will provide motors that comply with the mandate when applicable. SPECIAL MOTORS Two Speed 2 Winding 1 Wndg 1750/1140 1800/900 Special Enclosures Enclosed Expl. Proof 1750 or 3450 1750 or 3450 208v 1Ø ODP 277V 1Ø ODP RPM RPM *High Efficiency 1Ø ODP X X 3Ø ODP – – 3Ø ODP – – 1Ø X X 3Ø – X 1Ø X X 3Ø – – 1750 – X 3450 – X 1725/1140 – – 1750 – X 1750 – – 3450 – – X X X X – – X X X X X X X X X X X X X X X X X X – – 1 11⁄2 X – X X X X X X X X X X X X X X X X X – X X X X X X 2 3 – – X X X X X – X X – – X X X X X – – – – – X X X X 5 71⁄2 – – X – X X – – X X – – X X – – – – – – – – X X X X HP 1 ⁄4 1 ⁄3 1 ⁄2 3 ⁄4 Note: 2-sp. XP motors not available. See page 5 for expl. proof motor description. * High efficiency motors suitable for use with VFD controls. Note: All single phase ODP motors are not readily available marked for 208v 1Ø. (115v is std.) (X) Available 10 CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 CATALOG #37 www.centralfan.com PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 ) Residential Attic Fans IMPORTANT FEATURES Fan size selected should be capable of changing the entire volume of a home in approximately two minutes. (Do not include the attic space unless used for living .) • Slow speed belt driven for quietness • Ball bearing fan & motor-permanently lubricated • Compact construction with no unnecessary weight An average size home will require a 30 inch fan. Operation with a time switch is recommended. Turn fan on for hours desired and forget it. Fan shuts off automatically. • Two types to choose from • Single phase-115 Volts ODP Time switch installs in single gang switch box. Two speed operation affords additional flexibility. Two speed & timer switches in double gang box. Atlas Wall Fans Recommended for their quietness of operation. For attic window or wall installation in homes with reasonably air tight attics. Two smaller fans may be used if space is not available for one large fan. Fan installs against wall opening on the inside and the shutters on the outside. Shutters close automatically when the fan stops, keeping rain, wind and insects out. Ceiling opening may be used as an access to the attic if ceiling shutters are placed on the attic floor unfastened. FAN Model No. R24B R30C R36D R42E HP White Motorized Two 1 Speed 2 Speed Wall Ceiling Speed S M Shutter Shutter* Switch 1 ⁄4 ⁄3 1 ⁄2 3 ⁄4 X X X X 1 X X X X A24 A30 A36 A42 EM24 EM30 EM36 EM42 X X X X DIMENSIONS (inches) Fan RPM Air CFM Volume of home (Cubic ft.) 540 480 400 350 4800 7000 10000 16000 9600 14000 20000 32000 Fan O.D. Sq. 30 36 42 48 Fan Wall Wall Shutter Depth Opening Rd. O.D. Sq. 14 15 16 17 26 32 38 44 27 33 39 45 Wt. Lb. 60 70 90 110 *Motorized ceiling shutters are recommended if attic space is not air tight. Ceiling shutter dimensions are shown with Lay Down Fans. See page 7 for safety guards. (X) Available models Twelve hour timer switch available. Atlas Lay-Down Fans Easily installed-Simply cut hole in attic floor over hallway, Lay Down fan over this opening on top of sound absorbing plastic strips and install shutter on ceiling below. Sufficient vent area must be provided to let the hot air out of the attic through louvers on wall, vents under the eaves, or in ridge. Aluminum shutters fit flush with ceiling. Fan may be pulled up through ceiling opening. Most economical installation is ceiling shutter not motorized. FAN Model No. RS24B RS30B RS36C RS42C HP Gravity White Two 1 Speed 2 Speed Ceiling Speed S M Shutter* Switch 1 ⁄4 ⁄4 1 ⁄3 1 ⁄3 1 See page 7 for safety guards. X X X X X X X X E24 E30 E36 E42 *Baked white enamel Dimensions (Inches) Fan RPM 500 400 340 280 X X X X (X) Available models Air CFM Volume of home (Cubic Ft.) Fan O.D.(Sq.) Fan Height 9000 13000 18000 24000 30 36 42 48 14 15 16 17 4500 6500 9000 12000 Min. Vent Shutter Ceiling Area Req. Flange O.D. Opening (Sq. in.) 26 32 38 44 24 30 36 42 884 1248 1728 2300 Fan Wt. Lb. 60 70 80 90 Twelve hour timer switch available. Central-Aire Attic Cooling Fans FOR COOLING HOT ATTICS & REDUCING AIR CONDITIONING COSTS For easy to install sidewall installation. Complete with shutter and adjustable thermostat. Safety inlet guard. Lifetime lubricated quiet motors. Model Blade Dia. Max. attic floor area Sq. Feet* CFM HP K12AF K14AF K16AF 12" 14" 16" 1000 1500 2000 1000 1500 2000 1 ⁄20 1 ⁄15 1 ⁄8 Amp. RPM 1.4 2.1 2.4 Recommended setting for thermostat is 100 Degrees. (Shuts off at approx. 90) *1 CFM per ft2 of attic for summer venting. Recommended air intake area is exhaust CFM ÷ 300 = req. ft2 ** PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 CATALOG #37 www.centralfan.com 1500 1100 1100 Fan O.D. Opening (Sq.) Nec. (Sq.)** 16" 18" 20" 13" 15" 17" Ship Wt. Lb. 16 20 28 Optional humidistat UL 120V 7.5 amps (max.) adjustable setting Model PH CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 ® 11 DRAFT INDUCERS FOR VERTICAL VENTING [See page 14 for make-up (combustion) air devices.] DRAFT INDUCER SELECTION TABLE TJERNLUND AUTO-DRAFT INDUCERS assure positive draft when restricted boilers and furnaces, poor chimneys or negative pressures in building prevent proper exhaust of combustion gas. The Venturi action of Tjernlund Auto-Draft Inducers starts air moving up the stack instantly, keeps it moving smoothly. These units are adaptable to all heating systems. They are quick and easy to install and completely automatic in operation. Tjernlund's unique design and careful construction makes them trouble-free and reduces maintenance to a minimum. The Vari-Draft Control permits adjustment to the individual job requirement. Pipe Size In. Heater 270°F BTU Flue Gas Input S.P. CFM Model No. DJ-3 D-3 NOTE: 1. Inputs shown above are believed to be maximum capacities for inducers, when mounted on pipe sizes shown for ordinary jobs where a moderate amount of mechanical induced draft is required. 2. Consideration is given to typically higher static pressure requirements for larger installations, for the type of fuel burned, and for the type of draft control installed. 3. Where pressure requirements are unknown, or believed to be unusually severe, ask for complete performance curves or consult factory. DUCT BOOSTER MODEL DB-2 ® I IL Heater 390°F BTU Flue Gas Input S.P. CFM Heater BTU Input 530°F Flue Gas S.P. CFM 69000 .034 48 72000 .047 36 58000 .048 33 4 105000 .042 72 109000 .053 55 92000 .057 48 5 111000 .043 72 104000 .052 52 74000 .052 39 6 100000 .041 68 34000 .042 17 25000 .035 13 5 270000 .063 190 330000 .085 166 295000 .092 163 6 356000 .073 246 377000 .090 190 300000 .093 169 7 360000 .075 259 330000 .085 166 230000 .080 118 8 320000 .068 217 222000 .075 110 123000 .065 65 8 900000 .125 590 1200000 .143 603 1100000 .147 566 9 1110000 .135 765 1330000 .150 653 1100000 .148 566 10 1250000 .140 850 1260000 .145 615 840000 .136 440 12 1030000 .128 710 357 400000 .100 211 9 1460000 .145 1010 1970000 .175 989 1700000 .180 900 10 2080000 .170 1370 2460000 .185 1240 1900000 .180 1010 12 1920000 .160 1325 2230000 .182 1120 1500000 .170 789 14 1840000 .159 1270 1470000 .158 18 XL Oil Firing With Bar. Draft Control 3 16 HD The Tjernlund Duct Booster is the ORIGINAL money saving and energy efficient residential booster fan. It increases the comfort level in hard to heat or cool areas. No need to adjust the whole house thermostat or install auxillary heating or cooling equipment. Fits round or flat forced air heating/cooling ductwork. DB-2 features: easy installation, durability, economical price and manual or automatic operation. Boosts air flow up to 275 CFM (8” duct). Gas Firing With Bar. Draft Control Gas Firing With Draft Hood 710000 .115 740 825000 .135 453 184 900000 .120 620 650000 .113 340 350000 .095 650000 .099 450 440000 .095 220 200000 .075 106 16 4000000 .250 2760 4000000 .260 2010 3300000 .230 1763 18 3900000 .240 2650 3250000 .240 1660 2100000 .190 1103 20 2800000 .195 1935 2100000 .175 1079 1200000 .150 626 24 1500000 .150 1035 1100000 .125 503000 .110 266 20 5300000 .290 3690 5200000 .270 2440 3600000 .240 1870 24 3500000 .220 2415 3750000 .220 1680 2900000 .218 1550 527 MODEL D-3 MODEL I ® Model PS 1505 Proving Switch (Available as accessory. Recommended) Detects failure of motor or impeller & shuts off unit. (@ negative 0.05" w.c.) Universal Control UC-1 Used in conjunction with PS1505 eliminates control circuit compatibility issues. The UC-1 interlocks with dry contacts, 24VAC or 115V appliance control systems. Simply connect the PS1505 to UC-1 and select the system voltage required. Adjustable pre and post purge is also available. UC-1 can replace any relay or timer/relay previously installed. CLEAN AIR ONLY DO NOT USE IN FLUE Model No. DJ-3 Therm Volts HZ RPM Watts Amps Prot. 115 1550 35 D-3 115 60 1550 I IL 115 60 1725 1 XL 115 230 60 1725 3 HD 208 230 460 60 DB-2 DUCT BOOSTER 12 60 CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 .43* Unit Dimensions (in) H D X Y Ship Wt. 57⁄8 25⁄8 75⁄8 8 lbs. — 71⁄2 81⁄2 1 1 ⁄8 141⁄2 Slot W 1 ⁄8 85⁄8 10 lbs. 4 41⁄8 123⁄4 31 lbs. 15 34 lbs. 17 ⁄2 131⁄2 143⁄4 YES 187⁄8 181⁄2 101⁄2 51⁄8 163⁄4 53 lbs. NO 27 163⁄4 25 6 74 .96 YES ⁄4HP 5.4 YES ⁄4HP 10.8 5.4 1725 2 HP 6.3 6.4 3.2 9 1 ⁄2 9 7 83⁄4 10 3 241⁄2 176 lbs. * Impedance protected CATALOG #37 www.centralfan.com PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 TJERNLUND PRODUCTS, INC.® SIDE WALL VENTING See P. 13 for make-up (combustion) air devices FLUE GAS TEMP 600°F MAX. @ POWER VENTER (DO NOT USE ON CONDENSING FURNACES) HS-Series with Universal Control (UC-1) UL ® For all your gas and oil sidewall power venting needs. The UC-1 interlocks with dry contact 24VAC or 115V appliance control systems. UC-1 can replace any relay or timer/relay previously installed. Adjustable pre & post purge, prover switch circuit and LED status diagnostics indicators are all included. Accessories available for multiple appliance control. (HSJ not recommended for oil). Maximum Pipe Length (FT) At Stack Temp Inlet/ Outlet Dia. Model Numbers Vent Pipe BTU/HR Input 4" HS1 115V 1.76 amps 100' 100' 100' 23' 4" 150,000 200,000 250,000 300,000 100' 87' 40' 4' 60' 57' 12' –n 35' 27' –n –n 6" 150,000 200,000 250,000 300,000 100' 100' 100' 30' 100' 100' 92' –n 100' 100' –n –n 350,000 400,000 450,000 500,000 550,000 600,000 100' 100' 100' 100' 94' 15' 100' 100' 100' 72' –n –n 100' 100' 67' –n –n –n 350,000 400,000 450,000 500,000 550,000 600,000 100' 100' 100' 100' 100' 67' 100' 100' 100' 100' –n –n 100' 100' 100' –n –n –n 4" 6" HS2 115V 2.0 amps HS-3 100' 100' 100' 35' 4" Inlet Outlet Dia. Model Numbers Oil Fired 500°F 50,000 75,000 100,000 125,000 HSJ 115V 1.76 amps Gas Fired 300°F 400°F Maximum Pipe Length (FT) At Stack Temp Not Recommended n Vent Pipe Dia. 25% Dilution 400°F Gas Fired Power Burner With Barometric Draft Control 8" 450,000 500,000 600,000 700,000 100' 100' 100' 7' 100' 100' 100' 100' 10" 450,000 500,000 600,000 700,000 100' 100' 100' 21' 100' 100' 100' 100' 8" 700,000 800,000 900,000 1,000,000 1,100,000 1,200,000 100' 100' 100' 70' 32' 5' 100' 100' 100' 100' 100' 100' 10" 700,000 800,000 900,000 1,000,000 1,100,000 1,200,000 100' 100' 100' 100' 97' 14' 100' 100' 100' 100' 100' 100' 12" 700,000 800,000 900,000 1,000,000 1,100,000 1,200,000 100' 100' 100' 100' 100' 34' 100' 100' 100' 100' 100' 100' 1,200,000 1,400,000 1,600,000 1,825,000 100' 100' 100' 29' 100' 100' 100' 100' 1,200,000 1,400,000 1,600,000 1,825,000 100' 100' 100' 72' 100' 100' 100' 100' 1,200,000 1,400,000 1,600,000 1,825,000 100' 100' 100' 100' 100' 100' 100' 100' 8" 115 VAC 1 ⁄4 HP 3.2 AMP HS-4 8" 115 VAC 1 ⁄3 HP 6.3 AMP 6" 8" BTU/HR Input 100% Dilution 300°F Gas Fired Atmospheric With Draft Hood Or Draft Diverter 10" HS-5 115/208/230 VAC 1 HP 6.2 AMP @ 208 6.3 AMP @ 230 13.1 AMP @ 115 10" 12" 14" Accessory Controls VH1-3-4-6 Model VH1-8-10 HIGH TEMPERATURE VENT HOOD Description MAC-1E To interlock 1 additional appliance MAC-4E To interlock 3-5 additional appliances WHK-E To interlock a millivolt water heater NOTE: INSTALLATION MUST COMPLY WITH APPLICABLE CODES. Dimensions A Dia. B C VH1-3 3" VH1-4 4" VH1-6 6" Model D E F G Rough-In Dimensions 5 ⁄4" 7 ⁄4" 6 ⁄4" sq. Ship Wt. Lbs. Water Heater Vent Kit 4 Water heaters rated at 50,000 BTU/hr. or less can be vented by the VP-2. Water heaters rated from 51,000 to 120,000 BTU/hr. can be vented by the VP-3. Both packages come complete except for the pipe. 6 ⁄4" sq. 1 8 ⁄2" 10" 71⁄2" sq. 71⁄8" 13" 85⁄8" 73⁄8" 11" 8" sq. 7 81⁄2" dia. 77⁄8" 12" 91⁄2" 101⁄2" 10" 9" dia. 6 1 10" 1 3 3 VH1-8 8" 151⁄4" 9" 183⁄8" 20" – – 81⁄2" dia 12 VH1-10 10" 151⁄4" 9" 183⁄8" 20" – – 101⁄2" dia 13 PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 CATALOG #37 www.centralfan.com CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 13 Tjernlund Products, Inc. A cost effective way to ensure adequate combustion air for maximum performance of heating appliances. The IN-FORCER can be ducted up to 100 ft. allowing isolated mechanical rooms to be supplied with outdoor combustion air. Optional control panel allows interlock with up to 4 additional appliances. Where the IN-FORCER supplies combustion and dilution air each appliance must be electrically interlocked and supplied at the rate of 50 CFM per 100,000 Btu/hr. IN-FORCER MODEL APPLICATION CHART Model PAI-5* 5.4 Amps 115v PAI-6* 5.8 Amps 115v Not Applicable Multiple IN-FORCERS may be installed for capacities larger than shown on chart. IN-FORCERS may be roof or wall mounted. DIMENSIONS *Universal Control Model UC-1 The UC-1 interlocks mechanical draft and combustion air systems with gas/oil fired heating equipment. It can be activated by an 18-130 VAC heater control signal, pressure switch or relay using a 5 VAC control supplied by dry contacts. A UC-1 is needed with all PAI systems. Accessory Controls Model Description MAC-1E To interlock 1 additional appliance MAC-4E To interlock 3-5 additional appliances WHK-E To interlock a millivolt water heater 14 CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 CATALOG #37 www.centralfan.com PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 PAI-7 Not Applicable PAI-6 12.6 Amps 115v 6.3/6.2 Amps 208/230 Gas Power Burner Max Duct Rigid Duct Length in Diameter Equiv. Feet In Inches 100 6 100 6 100 6 100 6 100 6 100 6 100 6 100 6 98 6 100 8 100 8 100 8 100 8 100 8 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 12 100 12 100 12 100 12 100 12 100 12 100 12 100 12 100 12 100 12 100 12 100 12 PAI-5 1.5 Amps 115v Oil Flame Retention With Barometric Max Duct Rigid Duct Length in Diameter Equiv. Feet In Inches 100 6 100 6 100 6 100 6 100 6 100 6 100 6 100 6 100 8 100 8 100 8 100 8 100 8 95 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 12 100 12 100 12 100 12 100 12 100 12 100 12 100 12 100 12 100 12 100 12 100 12 100 12 100 12 PAI-4 PAI-4* 150,000 200,000 250,000 275,000 300,000 350,000 400,000 450,000 500,000 550,000 600,000 650,000 700,000 775,000 850,000 900,000 950,000 1,000,000 1,200,000 1,300,000 1,400,000 1,500,000 1,600,000 1,700,000 1,800,000 1,900,000 2,000,000 2,100,000 2,200,000 2,300,000 2,400,000 2,500,000 2,600,000 2,700,000 2,800,000 2,900,000 3,000,000 3,100,000 3,200,000 3,300,000 3,400,000 3,500,000 3,600,000 3,700,000 Gas Power Burner With Barometric Max Duct Rigid Duct Length in Diameter Equiv. Feet In Inches 100 6 100 6 100 6 100 6 100 6 100 6 100 8 100 8 100 8 100 8 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 12 100 12 100 12 100 12 100 12 100 12 100 12 100 12 100 12 100 12 100 12 98 12 PAI-3 PAI-3* 1.26 Amps 115v PAI-7* BTU/HR Input Motor Amps Gas Atmospheric Max Duct Rigid Duct Length in Diameter Equiv. Feet In Inches 100 6 100 6 100 6 100 8 100 8 100 8 100 8 52 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 95 10 100 12 100 12 100 12 100 12 100 12 100 12 100 12 98 12 Direct Drive Centrifugal Fans FOR GENERAL VENTILATION SYSTEMS INCLUDING RANGE HOOD EXHAUST All fans by Fantech utilize unique external rotor motors. The motors totally enclosed design allows the fan to operate in high moisture, lint and dust laden air. The motors are permanent split capacitor with automatic reset thermal overload protection and sealed ball bearings. All motors and impellers are designed as one integral unit for excellent motor heat dissipation, even at a low RPM. Air stream temperature to 140°F and 100% speed controllable. RVF Series Wall Mount • • • • Simple to install no extras are needed Galvanized steel housing with Baked Enamel finish Housing removable for easy access to motor and wiring Variable speed controllable RPM RVF4XL 2700 RVF6XL 3000 RVF8XL 2900 1.42 ® CFM @ S.P. (inches of H2O) 120V 1Ø Amps Model UL .1 .2 .4 .6 .84 180 172 154 136 118 1.46 360 346 315 285 258 410 392 348 312 282 235 Speed Control Model No. C64 .8 1.0 Ship Wt. Lbs. 1.2 1.4 91 57 28 213 164 92 14 180 128 16 10 (See below for dampers.) Dimensions In. Model a b c d e RVF4XL 101⁄4 13 6 11⁄4 4 RVF6XL 141⁄4 17 6 11⁄2 6 RVF8XL 141⁄4 17 6 11⁄2 8 RE Series Roof or Wall Mount • • • • DAMPERS Spring Loaded Butterfly Dia. (in.) 4 6 UL ® Suitable for pitched roof or wall mounting Galvanized steel housing with Baked Powder Coat finish Cover easily removable for access to motor and wiring Variable speed controllable Model RPM 120v 1Ø Amps 0 RE6 RE8XL RE10XL 2696 2830 3250 .80 1.48 3.61 227 409 753 1 ⁄4 199 362 721 CFM @ S.P. (Inches of H2O) 3 1 3 ⁄8 ⁄2 ⁄4 1 11⁄2 184 331 705 51 130 548 169 307 690 134 259 656 106 212 622 13⁄4 Ship Wt. Lbs 508 15 15 20 Speed Control Model No. C64 Model RSK4 RSK6 8 10 12 RSK8 RSK10 RSK12 14 16 RSK14 RSK16 PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 Dimensions In. CATALOG #37 www.centralfan.com Model a c d RE6 133⁄16 b 61⁄2 151⁄2 6 RE8XL 153⁄4 6 20 8 RE10XL 193⁄4 113⁄4 20 10 CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 15 FG Series In-Line Mount FOR GENERAL VENTILATION APPLICATIONS • Galvanized steel housing • Mounting bracket included for ease of installation UL • External wiring box for ease of connection ® • Auto thermal 120V 1Ø AMPS .73 CFM @ S.P. (Inches of H2O) 0 148 1 1 3 1 3 139 130 120 111 90 ⁄8 ⁄4 ⁄8 ⁄2 ⁄4 11⁄4 42 Ship Wt. Lbs. 8 Duct 4" RPM 2800 FG5XL 5" 2650 .76 191 175 161 146 131 102 75 45 – 8 FG6XL 6" 2950 1.26 392 368 346 326 305 263 228 191 150 11 FG8XL 1. 68 11⁄2 – Model FG4XL 8" 2950 1.31 521 496 469 440 411 345 282 231 180 12 FG10XL 10" 3000 2.11 590 565 541 519 496 442 394 339 290 14 FG12XL 12" 3250 3.21 801 783 765 747 729 692 655 611 566 21 Dimensions In. d D FG4XL 7 a 1 1 4 93⁄4 FG5XL 6 1 1 5 93⁄4 FG6XL 65⁄8 1 1 6 131⁄8 8 133⁄8 10 133⁄8 12 16 Model FG8XL b c 1 1 1 ⁄8 1 1 1 ⁄8 6 FG10XL 7 5 ⁄8 1 ⁄8 FG12XL 1 1 8 ⁄4 1 ⁄16 3 1 ⁄16 FR Series In-Line Mount FOR HOSTILE ENVIRONMENT VENTILATION • • • • • DB 10 DRYER BOOSTER SWITCH U L Housing manufactured of thermoplastic resin UL listed for outdoor use or wet locations Waterproof gasket on wiring box Mounting bracket included Auto thermal DO NOT USE IN COMBUSTIBLE ATMOSPHERE Allows FR110 or RVF4 to be used as booster fan for residential clothes dryers. The automatic pressure switch turns fan off and on in 10 minute cycles only when dryer is running. Allows fans to be used on runs up to 80' and 6 elbows of 4" rigid duct. (120v only) ® CFM @ S.P. (Inches of H2O) 120V 1Ø amps 0 .2 .4 .6 .8 1.0 Ship Wt. Lbs Model Duct RPM 1.5 FR110 4" 2900 .72 167 150 133 113 88 63 – 7 FR140 6" 2850 .53 214 190 162 132 99 46 – 7 FR160 6" 2750 1.14 289 260 233 206 179 154 89 8 FR225 8" 3100 1.35 429 400 366 332 297 260 168 11 FR250 10" 2850 2.04 649 600 553 506 454 403 294 13 Dimensions In. PB100 BATH FAN 100 CFM fan, ceiling grille and grille housing with damper. Uses 4" duct. PB190 PREMIUM BATH FAN 190 CFM fan, ceiling grille and grille housing with damper. Uses 6" duct. Home Ventilating Institute guidelines recommend one CFM per square foot for bathrooms 100 ft2 and under. Over 100 ft2 use 50 CFM/fixture, i.e., 1 toilet, 1 shower, 1 tub = 150 CFM. Model a FR110 51⁄4 FR140 7 5 ⁄8 FR160 3 6 ⁄8 1 FR225 61⁄4 11⁄2 FR250 1 6 ⁄4 b c 7 ⁄8 1 – 7 ⁄8 7 ⁄8 7 ⁄8 1 1 ⁄2 11⁄2 d1 d2 37⁄8 47⁄8 7 5 ⁄8 1 6 ⁄4 113⁄4 7 5 ⁄8 1 6 ⁄4 113⁄4 77⁄8 97⁄8 131⁄4 – 7 131⁄4 9 ⁄8 Speed Control Mounting Clamps CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 91⁄2 Accessories: 4" 5" 6" 8" 10" 12" C64 C64 C64 C64 C64 C64 Backdraft Damper RSK4 RSK5 RSK6 RSK8 RSK10 16 D CATALOG #37 www.centralfan.com FC4 FC5 FC6 FC8 FC10 PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 RSK12 FC12 FKD Series In-Line Centrifugal Fans • • • • • • • Backward curve mixed flow fan impeller 100% Speed controllable ball bearing 115V motor with overload protection Galvanized heavy gauge housing with baked powdercoat finish Inlet and outlet slip type duct connections Capable of operation in air stream temperatures up to 140°F Terminal box prewired UL approved CFM @ S.P. (INCHES H2O) Model NEW FKD 8XL FKD 10XL FKD 12XL FKD 14XL FKD 16XL FKD 18XL RPM 2700 2850 1700 1550 1600 1700 120V Amps+ Sones* 2.99 4.84 4.80 7.12 12.40 3.75** 14.1 21.0 18.7 19.9 25.0 32.0 1/4 3/8 761 1187 1832 2416 4014 5995 720 1147 1746 2303 3880 5874 1/2 680 1100 1649 2180 3743 5754 11⁄4 1 3/4 595 1006 1423 1936 3452 5500 499 911 1066 1662 3137 5199 393 810 606 1294 2794 4909 11⁄2 2 286 696 460 843 2379 4602 1242 3703 Ship Wt. Lbs 16 22 46 52 84 95 *The sound ratings shown are loudness values in fan sones at 5 ft. in hemispherical free field calculated per AMCA Standard 301. Values shown are for installation Type A: free inlet fan sone levels @ 1⁄2" W.G. Dampers see pg. 15. **FKD18XL 230/460V 3PH (amps shown are for 460V) FKD 8XL-10XL FKD 12XL-14XL-16XL-18XL Dimensions (inches) Model FKD8XL FKD10XL FKD12XL FKD14XL FKD16XL NEW FKD18XL A 8 10 12 14 16 18 A1 12 14 16 18 A2 14 16 18 20 C 121⁄2 14 177⁄8 193⁄4 221⁄8 221⁄4 D 151⁄2 15 187⁄8 201⁄4 231⁄4 291⁄4 E 7 8 F 15⁄8 15⁄8 15⁄8 13⁄4 ⁄ 78 11⁄2 11⁄4 2 FSD Series In-Line Centrifugal Fans • Backward curve mixed flow fan impeller • 100% Speed controllable ball bearing 115V motor with overload protection • Galvanized heavy gauge housing with baked powdercoat finish • Inlet and outlet “ductmate” type duct connections • Capable of operation in air stream temperatures up to 140°F • Terminal box prewired • UL approved CFM @ S.P. (INCHES H2O) Model RPM 120V Amps+ FSD 18 FSD 20 FSD 22 FSD 26 1700 1600 1600 1700 4.80 6.36 15.00 3.82** Sones* 1 12.4 14.1 21.0 27.0 2237 2921 4918 6644 ⁄4 3 1 3 ⁄4 1 1 ⁄4 1 ⁄2 2126 2766 4766 6473 1987 2605 4605 6317 1644 2241 4282 5981 1180 1829 3865 5608 658 1341 3337 5177 815 2716 3469 ⁄8 ⁄2 1 2 Ship Wt. Lbs 1308 1937 62 77 115 134 1 +Amperages are maximum for the given RPM. **FSD26 230/460V/3ø Amps shown are for 460V. *The sound ratings shown are loudness values in fan sones at 5 ft. in hemispherical free field calculated per AMCA Standard 301. Values shown are for installation Type A: free inlet fan sone levels @ 1⁄2" W.G. FSD26 is @3⁄4" W.G. Side View Inlet View Speed Controls Dimensions (inches) Model A sq. C sq. Model FSD18 175⁄8 153⁄4 C64 6 FSD 20 193⁄4 173⁄4 10 FSD 22 211⁄2 C65 19 15 26 201⁄4 C66 FSD 26 7 Note: Flanges extend ⁄8" beyond the “A” dimension PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 CATALOG #37 www.centralfan.com Max. Amps Additional Accessories: Backdraft Dampers Pg. 8 Vibration Isolators Pg. 39 CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 17 BATHROOM FANS ut Abo s Ask iscount ity D t n a Qu UL ® AMCA CERTIFIED 688 671, 676, 684 HD50, HD80 679 655 CEILING OR WALL MOUNTING - With backdraft damper - Plastic grille Control† CFM Noise Level Sones 688* 671* 684* 676* C64 C64 C64 C64 50 70 80 110 4.0 6.0 2.5 4.0 3 3 4 4 45 65 75 100 .9 1.15 .5 1.3 71⁄2 71⁄2 81⁄4 81⁄4 71⁄4 71⁄4 8 8 35⁄8 35⁄8 53⁄4 53⁄4 91⁄4 91⁄4 111⁄8 111⁄8 9 9 105⁄8 105⁄8 5 5 8 8 Commercial Duty continuous operation HD 50* HD 80* C64 C64 50 80 1.5 2.5 4 4 45 75 .4 .5 81⁄4 81⁄4 8 8 53⁄4 53⁄4 101⁄4 x 101⁄4 101⁄4 x 101⁄4 7 7 Fan with Light (100 watt) Fan with Light & Heat (1300w.) 679* 655 #68 #66 70 70 3.5 4.0 4 4 65 65 2. 12.8 81⁄4 14 8 81⁄4 53⁄4 53⁄4 111⁄8 x 95⁄8 153⁄4 x 105⁄8 8 14 All 115V. AC Type Bathroom fans Model Economy Deluxe Premium Premium Model 655 has separate blower for heater. †Optional model MHR control (see p.19) Round For Outlet Area Inches Sq. Ft. *U.L. listed for use in tub/shower enclosure with GFCI wiring. QTR80, QTR110 QTXE150 Amp Housing Size L W H Grille Size x x x x Ship Wt. Lbs. Metal grille for 671, 676, 684, 688 available. QTR110L 162, 164 750 Model Control** CFM Noise Level Sones Fan Only Fan Only Fan Only Fan w/Light/Nite Light QTR80* QTR110* QTXE150* QTR110L* C64 C64 C64 #67 80 110 150 110 1.0 1.5 1.4 1.5 4 4 6 4 75 100 140 100 Fan w/Light/Nite Light 750* #67 100 3.5 4 95 1.9 9 9 9 15 Rd. 12 Fan & 250 w. Infrared bulb (I bulb) (2) 250w. Infrared bulbs (2 bulbs) 162† 164† #68 #68 70 70 3.0 3.0 4 4 65 65 3.5 5.5 121⁄2 181⁄2 111⁄2 12 53⁄4 61⁄2 101⁄2 x 10 101⁄2 x 16 8 10 All 115V. AC Type *U.L. listed for use in tub/shower enclosure with GFCI branch wiring. Round Outlet Inches For Area Sq. Ft. Amp **Optional model MHR control (see page 19) .7 .9 .5 1.8 Housing Size L W H 1 11 ⁄4 3 5 10 ⁄8 7 ⁄8 Grille Size 13 x 14 13 x 14 14 x 15 123⁄8 x 14 Ship Wt. Lbs. 12.4 12.4 13.2 13.8 †R40 Infrared bulbs not included. Broan Kitchen & Bathroom Fans L300KMG 502, 503 All 115V. AC Type Wall or Ceiling Mount Ceiling Mount only (No dampers) 673 Model CFM Noise Level Sones Outlet Size Inches Fan Size Dia. 503 502 L300KMG* 160 270 286 5.5 7.0 2.8 31⁄4 x 10 31⁄4 x 10 8 8 10 Blower Amp. 1.7 1.7 2.7 673 505 504 60 180 350 4.0 4.5 6.5 61⁄4 81⁄4 101⁄4 6 8 10 1.0 1.5 1.7 504, 505 Housing Size L W 14 163⁄4 121⁄4 12 137⁄8 121⁄4 61⁄4 dia. X 55⁄16 81⁄4 dia. X 7 101⁄4 dia. X 7 H White Polymer Grille Size† Ship Wt. Lbs. 31⁄4 31⁄4 113⁄4 111⁄2 sq. 131⁄2 sq. 14 x 14 10 12 25 8 dia. 111⁄4 sq. 131⁄2 sq. 4 8 10 No. C64 variable speed control for all fans shown above. No. 472 damper with reducer to 8" for Model 504 †Metal grille for models 502, 503, 504, 505 available. *Suitable for use above cooking surface. Motor is thermally protected for higher temp., galv. steel impeller, metal grille. Dishwasher safe aluminum mesh filter LAFI (12" x 12" p. 19) 18 CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 CATALOG #37 www.centralfan.com PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 BROAN WALL FANS With backdraft dampers - Unbreakable white polymer grilles (paintable)** CFM Noise Level Sones RPM Amp. For Wall Thickness Exterior weatherhood 509 508 C64 C64 180 270 5.0 6.0 8 10 1500 1500 1.5 1.7 41⁄2 to 91⁄2 41⁄2 to 91⁄2 9" 11" 111⁄4 131⁄2 11 16 Chain-operated w/outside door 507 506 C64 C64 250 480 5.0 6.5 8 10 1500 1500 1.5 1.7 41⁄2 to 91⁄2 41⁄2 to 91⁄2 9" 11" 111⁄4 131⁄2 11 13 Motor-door 12C C64-3 380 4.5 10 1500 1.7 5 to 10 12" Sq. 131⁄2 20 12" Sq. 12" Sq. 131⁄2 131⁄2 8 9 All 115V AC Type Model Room to room thru wall 511 510 Control* (on fan) (on fan) **Optional metal grille available for 12C, 506, 507, 508, 509 180 380 Blade Dia. 3.5 5.5 8 10 1500 1500 1 3 to 5 ⁄2 3 to 51⁄2 1.5 1.7 Hole Required Dia. Grille Size Sq. Ship Wt. Lb. *Optional model MHR control (see below) electronic delay switch. ACCESSORIES WALL CAP Spring Loaded Damper Black Enamel Finish Model 639 Flat roof installation Aluminum – natural finish Built-in screen Curb mount installation Aluminum – natural finish Built-in screen Model 611 Model 611CM SHORT EAVE ELBOW Damper & Grille Black Enamel Finish Model 430 3" or 4" WALL CAP Damper Aluminum Model 642 TRANSITIONS Duct Transition Model 31⁄4" x 10" to 6" 31⁄4" x 10" to 7" 31⁄4" x 10" to 8" 411 412 413 ROOF CAP Damper & Bird Screen Black Enamel Finish Model 634 Model 644 (Alum.) 6", 7" or 8" WALL CAP Damper & Bird Screen Aluminum Model 641 (6") Model 643 (8") (No screen) ROOF CAP 3" or 4" Duct Damper & Bird Screen Black Enamel Finish Model 636 SWITCHES Washable Filters Model 8" OØ Aluminum (fits 505 & 509) 10" OØ Aluminum (fits 12C, 504, 508, 510 & 511) LAF1 12" x 12" (fits L300KMG) PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 LONG EAVE ELBOW Damper & Grille Black Enamel Finish Model 431 Model Timers C71-5 C71-15 C71-60 C72 5 min. 15 min. 60 min. 12 hr. (+ hold) Control Model C64 C64-3 66 68 67 Vari-speedFor Model 12C For Model 655 For Model 679, 162, 164 For QTR110L, 750 Model MHR: Electronic Fan-Light-Time Delay Control 120v 7.5 amp (fans) 120v 10.0 amp (heaters) 500 w. (lamps) Adjustable timer allows fan operation after light switched off. CATALOG #37 www.centralfan.com CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 19 L100 L150 L200 L250 L300 LOWEST SOUND LEVELS IN THE INDUSTRY • • • • • • • • • L400 L500 L700 L900 L1500 Attractive white grille blends with any decor. Specially designed resilient motor mount helps eliminate vibration Low RPM motors are permanently lubricated and thermally protected. Rugged 20 ga. steel housing with 1⁄2" acoustic insulation. Automatic backdraft damper located within duct connector. 8 position adjustable mounting brackets permit installation flexibility. Available in ceiling or in-line models. Air volume may be varied with speed control. Available in 240 vac and 277 vac (Special order). CFM* static press. (in water) Ceiling Model In-Line Model 0 L100 L150 L100L L150L L200 L250 L300 Motor Max. 120v RPM Amps ® Wt. Lbs. ⁄4 65 124 12 94 .8 1.4 640 710 1.1 1.3 6 Dia. 121⁄4 121⁄4 113⁄4 14 x 14 (P)** 23 186 242 296 177 233 287 144 201 254 1.8 2.3 2.9 740 830 905 1.8 2.1 2.6 8 Dia. 121⁄4 121⁄4 113⁄4 14 x 14 (P)** 23 344 463 640 299 434 607 182 339 534 2.4 3.1 4.6 735 810 960 1.4 2.2 2.9 41⁄2 x 181⁄2 211⁄2 121⁄4 113⁄4 231⁄4 x 14 (S) 34 877 842 1438 1371 793 1285 636 1103 4.0 8.4 650 955 3.0 5.0 8 x 12 22 18 18 237⁄8 x 197⁄8 (S) 64 ⁄4 3 1 136 181 93 141 80 132 L200L L250L L300L 231 272 312 196 250 303 L400 L500 L700 L400L L500L L700L 480 538 722 388 491 667 L900 L1500 L900L L1500L 918 1578 ⁄8 3 ⁄2 Housing (In.) L W H Grille Molded Plastic (P) Enameled Steel (S) Sones @ 1⁄10" 1 Outlet Size (in.) UL *CFM is reduced slightly on in-line models **Metal Grille L100-L300 Available at extra charge High Volume Cabinet Ventilators • • • • • • Designed for continuous operation. May be installed in ceiling or wall. Shipped in horizontal discharge - convertible to vertical discharge. May be converted to ceiling fan with grille kit. Air volume may be varied with speed control. (see below) L2000 is 115v; L3500EXL is 230v 1Ø L2000L L3500EXL (shown with optional grille and damper kit) CFM static press. (in water) 1 1 ⁄4 3 ⁄8 1 3 Model L2000L 0 ⁄8 1891 1791 ⁄2 ⁄4 1657 1508 1347 808 1.0 – L3500EXL 3608 3452 3278 3073 2893 2429 1693 UL ® Motor Sones @ 1⁄10" 9.8 RPM 965 Volts 115 Amps 5.8 Wt. Lbs. 89 14.8 1105 230 5.4 144 DIMENSIONS Inlet Outlet Outside Dimensions Model A B C D H W L2000L 123⁄8 353⁄4 333⁄4 73⁄4 145⁄8 145⁄8 L3500EXL 1 14 ⁄2 1 43 ⁄2 3 41 ⁄8 3 9 ⁄4 3 16 ⁄4 3 16 ⁄4 L 38 3 45 ⁄4 Mounting Hole Spacing E 73⁄4 1 10 ⁄4 Grille F G N Width Length 333⁄4 125⁄8 395⁄8 161⁄4 395⁄8 3 41 ⁄4 5 12 ⁄8 3 47 ⁄8 3 18 ⁄8 471⁄4 ACCESSORIES Speed Controls C64 (L100-L900) C65 (L1500-L2000L) C75 (L3500EXL) 230V Duct Transition 423 - 4 ⁄2" x 18" to 10" (L400-500-700) T81212 - 8" x 12" to 12" (L900-1500) 1 20 CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 Wall Caps 641 - 6" 643 - 8" 613 - 12" Roof Jacks 634 - 8" 437 - 12" Damper Kit D100 (L2000) D101 (L3500EXL) Grille Kit G102 (L2000L) G103 (L3500EXL) CATALOG #37 www.centralfan.com Radiation Dampers RD1 L100-L300 RD2 L400-L700 RD3 L900 & L1500 Brick vent BV8 - 73⁄4" x 81⁄8" x 4" BV12 - 73⁄4" x 12" x 4" BV16 - 73⁄4" x 155⁄8" x 4" PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 The T-Series range boasts features and a specification that marks a radical departure from current unit ventilation technology. • Designer-styled in two-tone grey to bring slim sophisticated good looks to today's commercial and residential environments. • A Speed Control Pack which gives one of three fixed speeds at the time of installation without the need for a Controller. When set on High, T-Series fans give a performance which outclasses competitive products. • Four sizes in each model, mean 12 performance options - so sizing is no longer a hit or miss affair. • An advanced interlocking shutter system effectively closing against backdraft — controlled by state-of-the-art electronics to ensure quiet and reliable actuation whatever the angle of installation. (exhaust or supply) • A new system of mounting for Window and Roof models which accommodates varying mounting thicknesses. Wall models have telescopic liners for all types of walls and a neat decorative trim. • For cleaning, T-series units can be completely dismantled in minutes without the need for special tools and all the non-electrical components can be washed thoroughly in warm soapy water. WINDOW MODEL TX Model—with electronically controlled integral shutter Technical Data WINDOW MODEL TX6WW Mounting Exhaust Performance Impeller Hole øO Guide (cfm) O (in) ø (in) Low Medium High 71⁄4 6 1 55 2.7 TX6WL 6 111⁄4 x 113⁄8 158 205 233 55 196 257 313 60 1.9 60 1.9 TX7WL 7 ⁄2 127⁄8 x 13 9 101⁄4 275 403 467 95 2.8 TX9WL 9 143⁄8 x 143⁄4 302 443 513 95 2.8 12 131⁄4 645 833 950 130 4.1 TX12WL 12 173⁄8 x 173⁄4 697 900 1027 130 4.1 Mounting Exhaust Performance Impeller Hole ø Guide (cfm) O ø (in) O (in) Low Medium High 6 1 TX7RF 7 ⁄2 TX9RF 9 12 71⁄4 55 2.7 91⁄8 x 95⁄8 174 225 257 55 2.7 284 60 1.9 TX7PL 7 ⁄2 105⁄8 x 111⁄8 216 282 344 60 1.9 101⁄4 275 403 467 95 2.8 TX9PL 9 121⁄8 x 127⁄8 333 488 565 95 2.8 593 767 873 130 4.1 TX12PL 12 151⁄4 x 153⁄4 748 967 1108 130 4.1 TX6PL 6 Exhaust Performance Guide (cfm) Watts Sones Low Medium High (Med) (Med) 233 13 ⁄4 172 Impeller Mounting øO (in) Hole (in) 178 1 147 PANEL MODEL 8 ⁄4 3 116 Watts Sones (Med) (Med) 1 2.7 284 TX12WW TX12RF 210 Exhaust Performance Guide (cfm) Watts Sones Low Medium High (Med) (Med) 233 TX9WW TX6RF 184 Impeller Mounting øO (in) Hole (in) 178 7 ⁄2 ROOF MODEL 145 WALL MODEL 8 ⁄4 TX7WW 3 Watts Sones (Med) (Med) 1 Darkroom Model: Exhaust or supply air ventilation without light intrusion . . . automatic integral shutter. Darkroom model dimensions are similar to roof model . . . except for the additional (interior) cowl. (derate 25%) OPTIONAL CONTROLS (All models) LIGHT-TIGHT GRILLE: black finish Model LT 12 x 12 12" sq. Model TFC 3 speed flush mntg. with reversing feature Model LT 12 x 18 Model TSAT thermostat (41°-86°F) 12" x 18" PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 Model TSC 3 speed surface mntg. with reversing feature Model HSTAT humidistat (45%-90% RH) CATALOG #37 www.centralfan.com CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 21 IN-LINE CENTRIFUGAL Direct drive or belt drive available Galvanized steel construction Aluminum airfoil impeller—non-overloading Bearing assembly L-10 life of 200,000 hours Operation to 200°F on belt drive applications; 140°F direct drive Versatile . . . mounts in any position . . . square in/out Easy access to all parts without disconnection of duct AMCA B Spark resistant construction standard NOT FOR GREASE EXHAUST DIRECT DRIVE SEE PP. 17, 23, 24, 25 FOR OTHER IN-LINE FANS Model No. XD100 XD120 B C HP 1 ⁄10 1 ⁄8 ⁄3 1 Single Phase Three Phase 1 Speed 2 Speed 1 Speed 2 Speed S M T R X X X X(V) X(V) X – – X – – – Accessories @ 1⁄4" Sones Vib. Isol. Vib. Isol. Fan RPM 0 3.0 7.5 10.0 1050 1300 ‡1550 460 570 680 4.4 7.5 14.0 955 ‡1140 1750 890 1068 1635 1 1 3 350 480 610 380 530 230 430 805 995 1590 650 910 1540 730 1490 ⁄8 ‡Maximum RPM shown with the standard one speed motor. For all lower RPMs add solid state speed controller. Model No. A XB9 B C D BELT DRIVE B XB120 C D E C D XB137 E F G D E XB161 F G H 11.7 14.0 16.7 21.0 1878 2274 2524 2933 675 875 990 1100 525 700 875 1000 325 600 750 975 – – X X Supp. Brkt. w/Isol. Drive Cover Chemical Resist. Coat 13 15 18 21 1570 1725 2060 2335 1360 1515 1845 2110 1235 1410 1760 2040 930 1250 1670 1965 X X X X X – X X X X Supp.Brkt. w/Isol. Drive Cover Chemical Resistant Coating 12 14 18 21 26 1365 1605 1830 2060 2310 1790 2195 2560 2920 3310 1490 1945 2360 2755 3170 1275 1705 2120 2555 3010 X X X – – X X X X X X X X X X Supp.Brkt. w/Isol. Drive Cover Chemical Resistant Coating 12 14 17 20 24 1210 1365 1570 1710 1865 2710 3095 3600 3940 4320 2485 2930 3470 3825 4215 2165 2680 3300 3690 4100 2375 3070 3510 3960 X X – – – X X X X X – X X X X Supp.Brkt. w/Isol. Drive Cover Chemical Resistant Coating 13 14 18 23 27 985 1055 1250 1410 1525 4285 4590 5560 6350 6910 3830 4215 5250 6080 6660 3375 3815 4930 5800 6400 1890 3160 4590 5510 6140 R Accessories 1 X X X X – X X – – X X X – – – – X X X X X X X X X X X X X X X X X X X X X – X X X X X 1 11⁄2 1 ⁄2 3 ⁄4 1 1 1 ⁄2 2 3 ⁄4 V=control included Supp. Brkt. w/Isol. Drive Cover Chemical Resist. Coat T 1 ⁄4 ⁄2 3 ⁄4 E F XB200 G H J 1 1 1 ⁄2 2 3 X X X X X F G XB245 H J K 1 1 1 ⁄2 2 3 5 X X X X – X – – – – X X X X X X X X X X Supp.Brkt. w/Isol. Drive Cover Chemical Resistant Coating 12 16 19 25 34 735 855 965 1100 1295 6210 7375 8425 9700 11530 5675 6940 8045 9370 11250 4130 6435 7645 9055 10970 G H XB300 J K L 11⁄2 2 3 5 71⁄2 X X X – – – – – – – X X X X X X X X X X Supp.Brkt. w/Isol. Drive Cover Chemical Resistant Coating 13 16 20 23 30 595 670 775 875 1010 8340 9610 11340 12960 15125 7255 8720 10690 12370 14625 5560 7665 9800 11700 14090 *Single phase 120v or 230v. (X) Available models See p. 10 for 208v, other special motors and controls. Disconnect switches (p. 43) 1 3 ⁄2 ⁄4 1 37 290 105 1450 1290 860 (X) Available models 1 11⁄2 180 450 625 875 150 450 675 21⁄2 2 O.V. = 1.0 CFM 150 500 260 O.V. = .571 CFM 760 1545 1880 740 1580 720 680 O.V. = .421 CFM 1530 1930 2350 2825 5060 7160 8680 10860 1500 2045 2485 2160 3055 3580 3155 4885 5590 7600 10070 1350 2240 1550 5870 9080 12150 22 CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 Model (Direct) XD100 XD120 A 14 177⁄8 B 189⁄16 247⁄8 Model (Belt) XB9 XB120 XB137 XB161 XB200 XB245 XB300 XB365 A 14 177⁄8 201⁄2 241⁄4 30 363⁄4 45 543⁄4 B 181⁄2 247⁄8 281⁄8 3211⁄16 393⁄4 481⁄16 585⁄16 711⁄16 48 64 100 130 155 170 220 1445 3030 230 1155 O.V. = .184 CFM 300 3030 4870 330 2305 O.V. = .119 CFM 400 9180 450 5613 O.V. = .082 CFM 5570 8880 10925 13500 Ship Wt. O.V. = .291 CFM 10470 5665 600 720 Backdraft dampers, see p. 8. DIMENSIONS MODEL XB Ship Wt. O.V. =.571 CFM 1 M ⁄6 ⁄4 ⁄3 1 ⁄2 1 ⁄14 ⁄3 1 ⁄2 3 ⁄4 1 ⁄13 ⁄2 3 ⁄4 ⁄8 Fan RPM S* 1 ⁄4 @ ⁄2" Sones HP 1 1 Approx. CFM Static Pressure (inches of water) Impeller Size 97⁄8 1115⁄16 C Max 12 113⁄16 113⁄16 1311⁄16 1311⁄16 1311⁄16 163⁄8 163⁄8 D Max 14 151⁄4 151⁄4 181⁄2 181⁄2 181⁄2 20 20 MODEL XD Impeller Size 103⁄16 1115⁄16 1311⁄16 1 16 ⁄8 20 241⁄2 30 361⁄2 CATALOG #37 www.centralfan.com PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 Duct Blower and Duct Filter All-purpose indoor cabinet blower with optional compact filter. • Install in any position-ball bearing blower • Insulated cabinet for quiet operation • Drawer type filter rack for easy maintenance • Access panels on both sides DUCT BLOWER Model No. 207 209 210 A B C D E O.V. FPM 759 1139 1519 1899 2409 RPM 567 822 975 1073 1469 BHP .02 .07 .14 .21 .43 RPM 737 822 975 1149 1414 BHP .04 .05 .14 .24 .48 RPM 1019 1051 1134 1272 1526 X X X X 800 1000 1200 1400 1600 951 1189 1427 1665 1902 468 534 613 696 782 .06 .09 .15 .23 .34 581 625 682 750 828 .07 .12 .18 .26 .37 786 802 834 881 936 .12 .17 .24 .33 .44 974 964 979 1009 1050 .19 .23 .30 .40 .52 1130 1118 1115 1132 1162 .26 .31 .38 .48 .60 1379 1384 1371 1362 X X X X 1000 1200 1400 1600 1800 964 1157 1350 1543 1736 422 470 525 582 642 .06 .10 .15 .22 .29 531 559 593 640 693 .09 .13 .18 .25 .33 713 728 749 770 807 .15 .20 .26 .33 .41 869 873 886 905 928 .23 .28 .34 .42 .51 998 1005 1009 1021 1040 .31 .40 .43 .52 .62 X X X X X 1600 2000 2400 2800 3200 3400 1097 1371 1646 1920 2194 2331 423 489 562 640 721 762 .12 .21 .35 .53 .78 .92 974 1217 1461 1704 1948 2142 1297 1461 1621 1785 1945 2110 2270 2464 323 372 431 491 553 604 302 328 356 384 413 442 472 508 .15 .26 .42 .59 .94 1.23 .40 .55 .72 .94 1.19 1.50 1.83 2.31 .17 .26 .40 .59 .83 .98 .21 .33 .49 .72 1.02 1.32 .50 .66 .83 1.06 1.32 1.65 1.98 2.48 658 690 734 786 846 877 529 546 575 608 646 679 448 460 473 491 510 532 555 584 .26 .37 .53 .73 .99 1.14 .34 .46 .66 .91 1.22 1.51 .74 .92 1.11 1.35 1.61 1.94 2.28 2.81 786 809 840 882 932 959 631 650 667 693 725 753 526 538 551 563 575 592 611 635 .35 .49 .66 .88 1.16 1.32 .49 .64 .81 1.10 1.44 1.77 .97 1.18 1.41 1.68 1.95 2.45 2.66 3.18 905 915 941 973 1015 2000 2500 3000 3500 4000 4400 4000 4500 5000 5500 6000 6500 7000 7600 507 559 620 687 758 796 399 432 471 523 580 628 351 373 395 420 445 471 499 533 716 736 754 771 798 823 610 605 615 630 641 653 666 687 1 B C 9209 D E ⁄4 ⁄3 1 ⁄2 3 ⁄4 1 1 B C 9210 D E ⁄4 ⁄3 1 ⁄2 3 ⁄4 1 C ⁄3 D 1⁄2 212 3 ⁄4 9212 E F 1 1 G 1 ⁄2 E F 215 9215 G H J F G 9218 H J K OUTDOOR DUCT BLOWER WITH HOOD AND WEATHER RESISTANT CABINET Single Speed† 1Ø 3Ø HP S†† T CFM 1 X – 400 ⁄6 1 X X 600 ⁄4 1 X X 800 ⁄3 1 X X 1000 ⁄2 3 X X 1300 ⁄4 1 218 For outdoor installation use heavy duty, weather resistant 9200 models. FILTER 3 ⁄4 1 11⁄2 2 3 1 11⁄2 2 3 5 X X X X X X X X X X X X X X X X X X X X X X – X X X X X X X X X X 1 1 ⁄8" 1 ⁄4" ACCESSORIES: Vibration hangers Aluminum mesh filters Intake hood (includes filter) RPM 2020 2051 2038 2053 .41 .48 .56 .65 1578 1590 .56 .67 1210 1221 1229 .47 .55 .65 1387 .66 .47 .61 .79 1.03 1.35 1106 1108 1118 1142 .72 .88 1.08 1.35 1276 1279 1278 .99 1.19 1.40 1420 1.27 .63 .83 1.09 1.27 1.65 2.01 1.28 1.44 1.69 2.00 2.32 2.7 3.07 3.61 856 879 899 918 935 950 754 752 746 741 750 765 777 791 .96 1.19 1.48 1.80 2.14 2.44 1.93 2.10 2.39 2.65 3.00 3.45 3.91 4.53 971 998 1020 1039 1058 1.30 1.58 1.92 2.31 2.74 1071 1101 1125 1146 1.65 2.0 2.37 2.81 868 871 869 864 857 858 868 2.62 2.96 3.22 3.58 3.79 4.20 4.69 967 971 973 972 969 3.32 3.75 4.03 4.51 4.82 DUCT BLOWER 18 153⁄8 209 21 210 221⁄4 212 215 218 80 90 90 100 115 150 170 240 275 330 INTAKE HOOD FILTER **Incl. Filters. Duct Blower Dimension 207 .72 – . H09 H10 H12 H15 H18 *S.P. drop @ max. CFM shown above. Model 80 1751 Intake Hood Model** .171 .124 .124 .241 .182 .241 Ht. B Ship Wt. Lbs. 70 SEE P. 45 FOR ROOF MOUNTED, SIDE INTAKE AIR SUPPLY UNITS Aluminum Mesh Filter Model S.P.* Width A 21⁄2" RPM BHP 2242 .42 2286 .58 2292 .71 2" BHP .37 .45 .58 .70 *Static pressure reduction on blowers designed for higher pressure could result in motor overload. (X) Available models † 2 speed 1Ø or 3Ø page 10 †† 1 phase 120v or 230v. See p. 10 for 208v 1Ø F207 F209 F210 F212 F215 F218 Static Pressure (inches water)* 3 1" 11⁄2" ⁄4" BHP RPM BHP RPM BHP RPM BHP .07 1257 .11 1448 .15 1761 .24 .12 1255 .16 1437 .20 1777 .32 .18 1308 .24 1473 .30 1768 .41 .29 1400 .35 1540 .43 1809 .57 .67 1618 .62 1713 .69 ⁄2" Length C Filter Dimensions Outlet Inlet D E F G H J K 23 81⁄4 93⁄16 141⁄2 95⁄8 11⁄4 11⁄4 7 18 23 101⁄4 1113⁄16 171⁄2 113⁄4 11⁄4 13⁄4 20 243⁄4 113⁄8 131⁄8 183⁄4 133⁄8 11⁄4 13⁄4 27 23 331⁄2 28 271⁄2 137⁄16 155⁄8 231⁄2 161⁄8 11⁄4 13⁄4 32 157⁄8 185⁄8 28 191⁄2 25⁄8 13⁄4 411⁄2 34 44 195⁄8 225⁄8 35 24 23⁄4 13⁄4 PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 ⁄8 7 ⁄8 7 ⁄8 7 ⁄8 7 ⁄8 11⁄8 CATALOG #37 www.centralfan.com L Inlet M Z A B N P Filter Size 157⁄8 133⁄8 – 173⁄4 153⁄8 16 131⁄2 141⁄8 x 165⁄8 19 16 21 21 18 191⁄8 161⁄8 163⁄4 x 197⁄8 201⁄4 18 26 221⁄4 20 203⁄8 181⁄8 183⁄4 x 211⁄8 213⁄4 x 257⁄8 25 21 31 27 23 251⁄8 211⁄8 301⁄2 25 34 321⁄2 263⁄4 305⁄8 251⁄8 253⁄4 x 31 353⁄8 315⁄8 40 37 331⁄4 351⁄4 311⁄2 321⁄4 x 357⁄8 CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 23 Tubemaster BELT DRIVE TUBEAXIAL FANS • • • • • Heavy duty all welded aluminum propeller Permanently lubricated ball bearings Maximum operating temperature to 200° F Tough acrylic epoxy finish Designed to operate in any position Note: Axial fans running at relatively high tip speeds tend to be noisy. Describe installation when ordering if fan noise is a potential problem. Important: Duct must not be sharply reduced or turned near fan inlet or discharge. Model No. C HA12 D E C D HA16 E F D HA18 E F G Approx. CFM Static pressure (inches water) Approx. 1 Phase* 3 Phase Fan HP S T RPM 1 ⁄3 1 ⁄2 3 ⁄4 1 ⁄3 1 ⁄2 3 ⁄4 1 1 ⁄2 ⁄4 3 1 11⁄2 3 ⁄4 0 1 ⁄4 3 ⁄8 1 3 ⁄2 ⁄4 X X X X X X 2320 2680 3070 1970 2270 2600 1790 2120 2470 1670 2030 2400 1520 1930 2330 X X X X X X X X 1976 2267 2600 2855 2994 3435 3940 4326 2613 3121 3666 4077 2353 2919 3525 3952 1929 2683 3337 3806 2871 3463 X X X X X X X X 1730 1980 2180 2495 4060 4640 5120 5860 3660 4270 4800 5580 3440 4080 4640 5450 3160 3880 4450 5300 2000 3370 4050 4980 X X X X X 1250 1375 1570 1730 1980 6750 7450 8500 9350 10660 5950 6750 7900 8800 10220 5520 6360 7600 8520 9970 5000 5910 7250 8250 9720 4650 6450 7950 9200 E F HA24 G H J 1 11⁄2 2 3 X X X X X F G HA30 H J K 1 11⁄2 2 3 5 X X X X –. X X X X X 942 1078 1187 1358 1610 10000 11500 12600 14450 17120 8800 10450 11750 13700 16440 8050 9850 11250 13250 16070 7050 9100 10650 12800 15680 G HA36 H J K 11⁄2 2 3 5 X X X – X X X X 799 880 1007 1193 14550 16050 18350 21750 12900 14500 17000 20600 11900 13700 16300 20100 10400 12650 15500 19400 H HA42 J K L M 2 3 5 71⁄2 10 X X – – – X X X X X 683 781 926 1060 1170 19650 22500 26650 30500 33550 17250 20400 25000 29100 32240 15750 19250 24000 28300 31520 13700 17900 23000 27600 30780 *1 phase 120v or 230v. See p.10 for 208v 1Ø 1 1660 2130 6700 9150 11700 14890 7800 11700 18100 13800 20750 25900 29260 Est. Ship Wt. 1870 49 51 54 2924 67 69 72 73 4600 74 77 78 88 7630 8600 114 115 125 134 151 10250 13980 229 239 248 265 279 10250 16450 284 293 310 324 17700 23800 27530 564 581 595 646 666 See Page 10 for • Enclosed motors • Exp. Proof motors • Multi-speed motors • Motor controls ACCESSORIES Size HA12 HA16 HA18 HA24 ComAcc- Chem. panion Drive Belt ess resist. Disc. Flanges Cover Guard Door Coat* Sw. X X X X X X X X X X X X X X X X X X X X X X X X HA30 HA36 HA42 X X X X X X X X X X X X X X X X X X *See page 38 for coatings (X) Available accessories See page 10 for 2-speed motors. (X) Available models DIMENSIONS (INCHES) Model A B C D F HA12 14.69 12.00 13.44 12.19 17.00 HA16 18.75 16.50 17.50 16.06 19.00 HA18 21.13 16.50 19.88 18.44 20.50 HA24 27.00 18.00 25.75 24.38 24.00 HA30 33.75 24.00 32.25 30.50 29.00 HA36 39.75 29.00 38.25 36.50 32.00 HA42 45.75 32.00 44.25 42.50 37.00 Dimensions are shown in inches. 24 CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 CATALOG #37 www.centralfan.com PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 CENTRIFAN® BELT DRIVE IN-LINE CENTRIFUGAL FAN • • • • Backward curved wheel Space saving in-line, tubular design Floor, wall or ceiling installation Vane straightened air flow (except C1050) Suitable for Kitchen Hood Exhaust C D E C1050 F G H 1 Speed S H.P. 1 ⁄3 ⁄2 ⁄4 1 3 1 11⁄2 2 1 ⁄3 ⁄2 ⁄4 Bearings and drive out of airstream All welded, rugged 10-16 ga. steel const. Max. temp. 150°F Arr. #9 Class 1 See Pages 16, 17, 22, 23, 24 For Other In-Line Fans SINGLE PHASE* Model No. • • • • THREE PHASE 2 Speed 1 Speed M T Approx. CFM 2 Speed R 1 1 ⁄4 3 ⁄2 RPM O.Vel @ 1 ⁄4 S.P. S.P. S.P. S.P. 1 S.P. 11⁄2 S.P. 2 S.P. 21⁄2 S.P. 3 S.P. 31⁄2 S.P. 4 S.P. ⁄4 X X X X X X X X X – – – X X X X X X – – – – – – 2010 2310 2639 2904 3325 3660 920 1086 1260 1408 1624 1794 1000 1180 1370 1530 1765 1950 900 1100 1300 1460 1700 1900 790 1000 1220 1390 1640 1850 640 900 1140 1310 1580 1800 –m 605 950 1160 1450 1675 –m –m 660 970 1315 1560 –m –m –m 640 1150 1425 –m –m –m –m 935 1275 –m –m –m –m –m 1100 –m –m –m –m –m 800 X X X X X X X X X X X – – – X X X X X X X – X X X X – – 1447 1657 1897 2088 2390 2630 3011 1000 1173 1367 1500 1740 1933 2250 1500 1760 2050 2250 2610 2900 3375 1360 1640 1950 2175 2550 2825 3275 1175 1510 1850 2090 2460 2750 3210 750 1335 1725 2000 2400 2700 3150 –m –m 1375 1750 2200 2550 3025 –m –m –m 1275 1975 2350 2900 –m –m –m –m 1625 2150 2750 –m –m –m –m –m 1700 2550 –m –m –m –m –m –m 2325 –m –m –m –m –m –m 2000 X X X X X X – X X X – – – – X X X X X X X X X X X X X X 1194 1367 1504 1722 1895 2170 2458 1040 1217 1361 1560 1726 1991 2257 2350 2750 3075 3525 3900 4500 5100 2150 2600 2950 3410 3800 4435 5015 1900 2400 2775 3300 3700 4325 4950 –m 2150 2600 3150 3600 4235 4890 –m –m 1900 2800 3300 4025 4700 – – – 2100 2925 3800 4500 –m –m –m –m –m 3450 4300 –m –m –m –m –m 2950 4000 –m –m –m –m –m –m 3675 –m –m –m –m –m –m 3100 C D E C1220 F G H J 1 11⁄2 2 3 D E F C1500 G H J K 1 11⁄2 2 3 5 E F C1820 G H J K 1 11⁄2 2 3 5 X X X X X – X X – – – – X X X X X X X X X X X X 1010 1112 1273 1401 1603 1901 1017 1130 1325 1479 1717 2048 3375 3750 4400 4910 5700 6800 3100 3500 4150 4700 5500 6625 2775 3210 3950 4500 5300 6450 2000 2900 3700 4300 5100 6300 –m –m 2900 3800 4725 6000 –m –m –m –m 4300 5700 –m –m –m –m 3200 5350 –m –m –m –m –m 4900 –m –m –m –m –m 3900 –m –m –m –m –m –m F G H C2220 J K L 1 11⁄2 2 3 5 71⁄2 X X X X – – X – – – – – X X X X X X X X X X X X 790 910 1000 1160 1370 1550 1000 1200 1350 1550 1850 2000 5100 5900 6700 7800 9200 10300 4800 5700 6400 7500 9000 10100 4100 5200 6000 7200 8700 10000 3400 4600 5600 6700 8500 9800 –m –m 4480 6100 8000 9500 – – – 5000 7200 9100 – – – – 6500 8500 –m –m –m –m 5580 7900 –m –m –m –m –m 7100 –m –m –m –m –m 6100 G H C2450 J K L M 11⁄2 2 3 5 71⁄2 10 X X X – – – – – – – – – X X X X X X X X X X X – 780 850 980 1160 1330 1470 1120 1250 1480 1720 2000 2200 6700 7400 8800 10400 12000 13000 6300 7200 8400 9800 11800 13000 5600 6600 7850 9700 11300 12600 4800 6000 7600 9500 11000 12200 –m –m 6500 8800 10500 12000 –m –m –m 7800 9800 11400 –m –m –m 6600 9300 10800 –m –m –m –m 8400 10000 –m –m –m –m 7200 9000 –m –m –m –m –m 8400 1 3 1 ⁄2 ⁄4 3 3 ⁄4 *1 phase 120v or 230v. See page 10 for 208v 1Ø and other special motors. Bare Wt. 110 130 195 260 390 460 (X) Available models Model Pair Comp. Flanges Belt Guard Floor Legs Access Door Chemical Resist. Coating Weather Cover Spark Resist. C1050 X X X X X X C1220 X X X X X X X X X X X C1500 X X X X X X X X X X X C1820 X X X X X X X X X X X C2220 X X X X X X X X X X X C2450 X X X X X X X X X X X Ceiling Vlb. Brackets Isolators X X B* C* Disc. Switch X X X SEE PAGES 16, 17, 22, 23, 24 FOR OTHER CENTRIFUGAL IN-LINE FANS *See page 38 for description of spark resist. constr. (X) Available accessories Fan Dimensions Size A C1050 14 1 C1220 16 9 C1500 C1820 C2220 C2450 ⁄8 ⁄16 5 20 ⁄16 11 24 ⁄16 5 30 ⁄16 1 33 ⁄4 B C 1 16 5 18 ⁄2 ⁄8 5 26 ⁄8 3 32 ⁄8 1 39 ⁄2 5 43 ⁄8 18 21 D E 1 16 9 18 ⁄8 ⁄16 5 22 ⁄16 11 26 ⁄16 3 32 ⁄4 3 35 ⁄4 PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 F 23 H 2 2 9 1 ⁄2 1 18 ⁄4 1 22 ⁄2 – – – – – – – – 26 ⁄8 1 31 ⁄8 7 36 ⁄8 1 24 30 18 39 33 19 3 ⁄4 3 43 ⁄4 L 14 21 ⁄4 1 12 ⁄4 3 14 ⁄8 1 K ⁄8 1 29 ⁄8 7 34 ⁄8 1 10 1 J 9 ⁄2 1 22 ⁄4 1 26 ⁄2 1 9 G 1 1 12 1 2 2 CATALOG #37 www.centralfan.com ⁄16 ⁄16 9 ⁄16 9 ⁄16 9 ⁄16 7 ⁄8 M P Q 4 5 8 19 3 15 4 5 8 22 5 17 4 4 6 6 N ⁄16 ⁄16 5 ⁄16 5 ⁄16 5 ⁄16 3 ⁄8 12 ⁄4 ⁄8 1 24 ⁄2 1 29 ⁄2 12 – 16 – 8 BC Shaft Dia. 1 1 9 1 ⁄8 ⁄16 5 21 ⁄16 11 25 ⁄16 9 31 ⁄16 1 34 ⁄2 1 3 ⁄16 ⁄16 7 1 ⁄16 1 3 1 CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 25 RADIAL BLADE BLOWERS DIRECT DRIVE - ARRANGEMENT 4 Recommended for small kitchen hoods where grease filters may or may not be used-also for air containing dirt, dust, lint or other foreign material. Wheels-Constructed with straight radial blades of heavy cast aluminum-Self cleaning. Dynamically balanced, Spark resistant. Suitable for 250°F. Max. CLOCKWISE ROTATION-bottom horizontal discharge is furnished unless otherwise specified. Discharge position and rotation can be changed. Rotation is as viewed from motor end. (See page 31.) CW-BH Blower ASSEMBLED AND TESTED-WITH BALL BEARING MOTOR WHEN ORDERING: INCLUDE PHASE, VOLTS, ROTATION & DISCHARGE 115/230V CFM Static pressure (inches water) SINGLE PHASE THREE PHASE Model No. KE KE KE KE KE 8 9 11 12 14 1 Spd. 2 Spd. 1 Spd. 2 Spd. ⁄8 S M T R RPM 0 1 X X X X X X X X X – X X X X X – – X X X 1750 1750 1750 1750 1750 550 880 1430 2375 3420 ⁄6 1 ⁄4 1 ⁄2 1 2 Special Motors: Multi-speed, enclosed, expl. prf - see page 10 *Single phase - 120v or 230v For 208v 1Ø - see page 10. 1 1 HP 3 ⁄4 510 825 1385 2300 3325 1 ⁄8 470 765 1335 2220 3230 3 ⁄2 425 705 1275 2140 3125 365 635 1225 2060 3025 ⁄4 1 150 480 1100 1890 2820 200 945 1700 2595 11⁄4 11⁄2 730 1485 2350 Ship Wt. Lb. 2 430 1185 2045 35 40 60 120 150 350 1010 (X) Available models ACCESSORIES Blower Model KE KE KE KE KE Vibration Pads Drive Cover Chemical Resistant Coating X X X X X X X X X X X X X X X 8 9 11 12 14 *Square…Model A14 shutter (p. 8.) Shutter to fit Discharge Disc. Switch X X X X X* X X X X X (X) Available accessories Outlet Velocity (FPM) = CFM Area (Sq. Ft.) Tip Speed (FPM) At 1750 RPM = 458 x Dia. (in.) Construction is of 16 gauge steel housings and bases— Arc welded for rigidity. Finish is Dark Gray epoxy. Blower Dimensions Model No. KE-8 Wheel 73⁄4 x 4 KE-9 9x5 KE-11 7 3 1 1 10 ⁄8 x 5 ⁄8 KE-12 12 ⁄2 x 7 ⁄2 KE-14 131⁄2 x 81⁄8 Bore* 1 ⁄2 1 ⁄2 5 ⁄8 5 ⁄8 7 ⁄8 Certified Dimension Prints furnished upon request OUTLET A 11 1 12 ⁄8 3 14 ⁄4 3 B C D E 8 81⁄4 53⁄8 5 8 3 1 9 1 10 ⁄4 3 11 ⁄4 1 6 ⁄2 8 5 16 ⁄8 10 ⁄2 13 ⁄4 9 ⁄8 175⁄8 101⁄2 145⁄8 103⁄4 5 5 ⁄8 F 7 7 7 1 6 ⁄8 7 ⁄2 3 3 7 ⁄8 8 ⁄4 8 83⁄4 INLET G H J K L M* 1 6 45⁄8 63⁄4 67⁄8 103⁄4 5 5 ⁄8 3 7 ⁄4 1 7 ⁄8 3 6 ⁄4 1 9 ⁄8 1 8 ⁄8 13 ⁄4 10 ⁄8 1 8 ⁄2 1 11 ⁄2 1 10 ⁄2 3 15 ⁄16 111⁄8 93⁄8 125⁄8 113⁄8 163⁄4 ⁄2 1 ⁄2 3 ⁄4 7 ⁄8 7 ⁄8 3 6 ⁄4 8 1 3 11 ⁄4 1 N 3 ⁄8 3 ⁄8 3 ⁄8 9 ⁄16 9 ⁄16 O P R V X 33⁄4 8 8 – 81⁄2 1 9 ⁄4 – 93⁄8 3 – 113⁄4 5 4 ⁄16 9 1 5 ⁄16 10 3 1 10 ⁄4 1 1 6 ⁄8 13 ⁄4 13 ⁄4 11 ⁄8 17 7 141⁄2 145⁄8 121⁄4 17 *Bore & "M" varies with frame. 26 CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 CATALOG #37 www.centralfan.com PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 Pressure Blowers DIRECT DRIVE - ARRANGEMENT 4 Pressure blowers are generally used on industrial applications for small high pressure exhaust systems where air is laden with dust or grit and also for supplying high pressure air for conveying and cooking. Not suitable for heavy, coarse material. See p. 34. WHEELS—Constructed with straight radial blades of heavy cast aluminum for self cleaning features, dynamically balanced and designed for efficient operation—Spark resistant. Suitable for 250°F Max. CLOCKWISE ROTATION—Bottom Horizontal discharge is furnished unless otherwise specified. Discharge position and rotation can be changed. Rotation is as viewed from motor end. (See p.31.) CW-BH Blower ASSEMBLED AND TESTED - WITH BALL BEARING MOTOR WHEN ORDERING: INCLUDE PHASE, VOLTS, ROTATION AND DISCHARGE Model No. PW PW PW PW PW 8 9 11 12 14 HP With Standard Open Motor 1 Phase* 3 Phase S T 1 ⁄3 1 ⁄3 X X X X – 1 2 5 X X X X X *Single phase is 115V or 230V RPM 1 3500 3500 3500 3500 3500 291 526 800 1190 2280 2 3 231 470 741 1130 2180 CFM Static pressure (inches water) 5 6 7 8 4 165 410 676 1065 2070 330 600 1000 1960 200 500 930 1840 400 860 1720 300 780 1570 9 690 1400 575 1240 10 11 410 1080 880 12 Ship Wt. Lb. 670 35 40 65 80 135 (X) Available models ACCESSORIES Special Motor Model PW PW PW PW PW 8 9 11 12 14 Chemical Vibration Drive Resistant 3Ø Pads Cover Coating Enclosed Exp.Proof‡ 1Ø 3Ø 1Ø X X X – – X X X X X X X X – – ‡See p. 5 for motor description – – X X X X X X X X X X X X X Disc. Switch X X X X X X X X X X (X) Available accessories Outlet Velocity (FPM) = CFM Area (Sq. Ft.) OV [4005 ]2 Vel. Press.= Tip Speed (FPM) At 3500 RPM = 916 x Dia. (in.) Construction is of 16 gauge steel housings and bases—Arc welded for rigidity. Finish is Dark Gray Baked epoxy. Blower Dimensions Blower Wheel 3 1 PW-8 7 ⁄4 x 2 ⁄4 PW-9 9 x 23⁄4 PW-11 105⁄8 x 3 PW-12 121⁄2 x 3 PW-14 131⁄2 x 43⁄8 Bore* Certified Dimension Prints furnished upon request OUTLET A B C D E F 1 11 8 3 3 5 7 1 121⁄8 8 31⁄2 31⁄2 55⁄8 7 143⁄4 9 4 31⁄2 67⁄8 71⁄2 17 8 5 4 8 61⁄2 71⁄8 53⁄4 8 99⁄16 ⁄2 ⁄2 5 ⁄8 7 ⁄8 11⁄8 175⁄8 111⁄4 INLET P R 16 4 5 6 ⁄8 1 8 ⁄2 203⁄4 5 71⁄2 93⁄8 75⁄8 203⁄4 6 85⁄8 95⁄8 201⁄8 7 22 8 G H J K L 1 3 5 ⁄8 7 4 ⁄8 7 5 ⁄8 7 5 ⁄8 1 63⁄8 53⁄4 67⁄8 63⁄4 71⁄4 61⁄2 8 81⁄4 71⁄2 9 101⁄2 95⁄8 113⁄8 ⁄2 ⁄2 3 ⁄4 3 ⁄4 1 11 O X S T V 13 ⁄8 12 – 145⁄8 16 – 113⁄4 181⁄4 16 – 10 105⁄8 183⁄8 15 – 111⁄2 125⁄8 211⁄2 15 71⁄4 1 *Could vary depending on motor frame size used. PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 CATALOG #37 www.centralfan.com CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 27 DIRECT DRIVE UTILITY BLOWERS FORWARD CURVE WHEELS - SINGLE INLET - ARRANGEMENT 4 For general ventilation where duct systems are required. Compact, easy to mount and quiet in operation, these blowers are designed to deliver large volumes of air economically. Ideal for wash rooms, boiler rooms, restaurants, and small hood exhaust. Note: Low static pressure systems may overload certain motors. Where this condition exists, increase the static pressure with duct work, dampers, etc. CLOCKWISE ROTATION—Bottom horizontal discharge (as shown in photo) furnished unless otherwise specified. DISCHARGE POSITION easily changed to any one of eight different positions. Rotation as viewed from the motor end. (See page 31.) Suitable for temperatures to 250°F. (500° with slinger) Wheels are heavy gauge steel construction. Available with spark resistant aluminum wheels. CW-BH Blower ASSEMBLED & TESTED: With Open Ball Bearing Motor. CFM Model HP D5 A A D6 B 1 A D8 C ⁄6 ⁄6 1 ⁄6 1 ⁄6 1 ⁄3 D9 C 14 D11 E 12 Static Pressure (inches water) 120v Single Phase 3 Phase 1 Speed 2 Speed 1 Speed S M T 1 ⁄ ⁄ 1 ⁄8 1 184 390 595 169 330 560 144 250 515 112 100 470 420 365 300 1140 1750 760 1150 680 1085 620 1050 535 1005 430 960 915 865 RPM 0 1750 1140 1750 3 ⁄4 1 ⁄8 5 ⁄2 3 ⁄8 ⁄4 60 X X X X X(v) X X X X(v) X X – X – X X X(v) X 850 1140 875 1180 835 1160 780 1125 680 1090 470 1035 965 855 X X X 850 1140 1520 2060 1380 1970 1290 1870 1145 1800 1010 1710 860 1605 1500 (V) = Variable speed includes solid state control Ship Wt. 11⁄4 1 25 25 25 750 40 40 580 70 1290 80 1020 (X) Available models HIGH SPEED UTILITY BLOWERS For high static pressure applications such as garage monoxide systems, electronic cooling and installations requiring extra long duct lengths. 115/230V CFM Static pressure (inches water) SINGLE PHASE THREE PHASE Model No. D** D9 E** F** F** D11 G** H** 1 Spd. 2 Spd. 1 Spd. 2 Spd. HP S M T R RPM 1/2 1 X X X X X X X X – 1750 1 X X X X X 1720 1 11⁄2 2 X X X X – – X X X – – X 1750 X X X ⁄2 3 ⁄4 1 3/4 1020 895 X X 1675 1620 X X X X X X *120v or 230v 1Ø See p.10 for 208v 1Ø motors. **D9D Not available spark resistant or CCW. EXTRAS Model No. 1 1/4 1 1/2 1 3/4 2 810 1550 1550 733 1445 1445 615 1290 1290 2 1/4 1100 1100 X 1900 2500 1465 1840 2415 1425 1730 2240 1280 1600 2130 2 1/2 Ship Wt. Lb. 2 3/4 60 70 80 1120 1450 1990 X = Low S.P. will cause motor overload. 910 1280 1850 100 110 120 1040 1660 (X) Available models Spark Shutter Chemical XP Vib. Resist. to fit Heat Resist. Motor‡ Pads Wheel Disch. Slinger Coating 1 Phase Drive Cover D5 D6 D8 X X X X X X X X X X X X X X X X X X X X X D9 D11 X X X X X X X X X X X X X X *Square…Model A8 (Page 8) ‡See p. 5 for motor description (X)Available accessories SEE PAGES 36, 37, 38 FOR SOLID PVC BLOWERS BLOWER DIMENSIONS Model No. D5 D6 D8 D9† D11 E,H D11 F D11 G Wheel ⁄4 x 21⁄2 61⁄4 x 3 73⁄4 x 37⁄8 1 9 x 4 ⁄2† 5 10 ⁄8 x 51⁄4 105⁄8 x 3 5 10 ⁄8 x 4 4 A 3 28 C B 3 ⁄8 93⁄8 8 11 ⁄8 14 ⁄4 3 8 8 1 11 D 1 ⁄8 73⁄8 81⁄4 3 10 ⁄4 3 11 ⁄4 5 7 8 1 12 *M varies with motor frame size OUTLET ⁄2 3 ⁄8 41⁄4 53⁄8 1 6 ⁄2 3 E 3 6 5 7 5 ⁄8 6 ⁄8 5 7 8 F ⁄4 41⁄4 3 7 7 10 INLET G 1 ⁄2 1 ⁄2 1 ⁄2 1 ⁄2 3 ⁄4 H 1 3 ⁄2 CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 3 3 ⁄4 L M* 1 ⁄2 117⁄8 121⁄2 1 13 ⁄4 151⁄2 4 ⁄8 4 6 6 45⁄8 63⁄4 67⁄8 5 3 1 3 6 ⁄4 8 ⁄8 †D9, C, E, F wheel = 9 x 41⁄2 K ⁄8 5 7 5 J 3 3 ⁄8 6 ⁄4 5 ⁄4 9 ⁄8 5 7 3 1 ⁄8 8 ⁄8 7 1 1 11 N 3 ⁄8 3 ⁄8 3 ⁄8 3 ⁄8 3 ⁄8 O P R 3 4 4 ⁄4 31⁄8 33⁄4 3 4 ⁄8 2 5 1 5 6 ⁄8 71⁄8 8 8 81⁄2 9 10 1 ⁄4 10 ⁄4 As above (D11) except as shown D9D wheel = 9 x 3 (cw steel only) CATALOG #37 www.centralfan.com X 5 PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 9 3 ⁄4 81⁄2 7 9 ⁄8 ⁄4 3 11 BELT DRIVE UTILITY BLOWERS Recommended for clean air ventilation where static pressures do not vary over a wide range. Use backward curved blowers (next page) where system conditions vary or pressure not known. Not recommended for kitchen hood exhaust. BLOWER DIMENSIONS PAGE 31 Wheel rotation and discharge position - page 31 Blower dimensions - page 31 Special motors and controls - page 12 CCW SIZES SHOWN ARE NORMAL STOCK. OTHER SIZES ALSO AVAILABLE. 115/230v SINGLE PHASE Model No. A B 8 C D E A B 9 C D E B C 11 D E F C D 12 E F G D E 15 F G H E F 18 G H J HP 1 ⁄6 ⁄4 ⁄3 1 ⁄2 3 ⁄4 1 ⁄6 1 ⁄4 1 ⁄3 1 ⁄2 3 ⁄4 1 ⁄4 1 ⁄3 1 ⁄2 3 ⁄4 1 1 1 1 ⁄3 1 ⁄2 3 ⁄4 1 11⁄2 1 ⁄2 ⁄4 3 1 11⁄2 2 3 ⁄4 1 11⁄2 2 3 3 ⁄4 CCW-TH Blower See Note Below for CFM vs. RPM vs. S.P. Relationship THREE PHASE 1 @ ⁄4" S.P. 1 Speed 2 Speed 1 Speed 2 Speed Blower S M T R RPM* Approx. CFM* Static pressure (inches water) ⁄4 1 11⁄2 2 O.V. FPM 1 1 3 ⁄4 ⁄2 X X X X X – X X X X – X X X X – – – – – 1200 1300 1400 1600 1800 2200 2700 2900 3400 4000 650 800 850 1000 1200 590 700 800 950 1150 560 650 750 900 1100 500 600 700 850 1050 X X X X X – X X X X – X X X X – – – – – 800 900 1000 1200 1400 1700 2000 2200 2600 3000 800 950 1050 1200 1400 750 875 1000 1150 1350 650 800 950 1100 1300 600 750 850 1000 1250 X X X X X X X X X X X X X X X – – X X X 700 800 900 1100 1200 1700 2000 2400 2700 3100 1100 1300 1500 1700 2000 1050 1200 1400 1600 1900 950 1100 1250 1550 1800 800 1000 1200 1500 1700 X X X X X X X X X – X X X X X – X X X X 600 700 800 900 1000 1900 2200 2600 2900 3400 1650 1900 2200 2500 2900 1500 1750 2100 2400 2800 1300 1650 2000 2200 2700 1150 1500 1900 2150 2600 X X X X X X X X – – X X X X X X X X X X 500 600 700 800 900 2000 2300 2600 2900 3300 2500 2900 3300 3700 4200 2350 2800 3200 3600 4100 2100 2700 3000 3500 3800 1900 2400 2800 3400 3700 X X X X X X X – – – X X X X X X X X X X 400 500 550 600 700 1900 2200 2500 2800 3100 3600 4100 4700 5300 5800 3400 3800 4500 5000 5700 3200 3600 4300 4800 5600 2800 3400 4100 4700 5500 X X – – – X X X X X X X X X X 350 400 450 500 550 1900 2100 2400 2700 3100 4300 4800 5600 6200 7200 4000 4500 5300 6000 7000 3500 4200 5000 5700 6700 3000 3700 4700 5300 6500 E F 20 G H J 1 11⁄2 2 3 X X X X X F G 22 H J K 1 11⁄2 2 3 5 X X X X – X – – – – X X X X X X X X X X 350 400 425 475 500 2000 2400 2600 3000 3200 5600 6700 7300 8500 9000 5000 6200 6800 8000 9000 4700 5600 6400 7600 9000 4200 5200 6200 7400 9000 F G 24 H J K 1 11⁄2 2 3 5 X X X X – X – – – – X X X X X X X X X X 300 350 400 450 500 1900 2200 2500 2900 3500 6600 7700 8800 10000 12000 5900 7200 8300 9600 11600 5200 6600 7600 9000 11100 4200 5900 6900 8500 10500 500 650 800 950 3 Ship Wt. O.V. = 3.38 x CFM 60 2 500 750 900 1 ⁄2 650 800 750 80 O.V. = 2.14 X CFM 750 950 1200 900 1100 1000 65 900 90 O.V. = 1.57 X CFM 1050 1350 1600 1500 1300 105 O.V. = 1.17 X CFM 1200 1700 2000 2500 1400 1700 2300 1500 2000 1800 O.V. = .78 X CFM 2000 2500 3100 3500 2100 2800 3300 2400 3000 2700 O.V. = .53 X CFM 2800 3600 4200 5300 3200 3800 4900 3500 4500 4100 4800 4100 180 200 265 290 300 340 400 420 6200 7800 5200 7400 7000 O.V. = .29 X CFM 5100 6000 7500 9800 160 320 4000 5500 O.V. = .35 X CFM 4600 5400 6700 8400 140 280 O.V. = .43 X CFM 3900 4800 6000 75 5000 6000 8900 5800 7800 6500 430 460 510 1 *Exhibited blower RPM (above) relates to ⁄4 " static pressure performance only. Higher RPM are necessary to yield the performance shown at higher static pressures. AMCA CLASSIFICATION FOR SPARK RESISTANT CONSTRUCTION TYPE A All parts of the fan in contact with the air or gas being handled shall be made of nonferrous material. Steps must also be taken to assure that the impeller, bearings, and shaft are adequately attached and/or restrained to prevent a lateral or axial shift in these components. Model 8 9 11 12 15 18 20 22 24 Weather Vib. Cover Isolators X X X X X X X X X X X X X X X X X X †Max temp. for Type "B" = 250°F. Disch. Shutter X X X X X X X X X For special motors - p.10 Access Door X X X X X X X X X Blower Dimensions: (Page 31) TYPE B The fan shall have a nonferrous impeller and nonferrous ring about the opening through which the shaft passes. Ferrous hubs, shafts, and hardware are allowed provided construction is such that a shift of impeller or shaft will not permit two ferrous parts of the fan to rub or strike. Steps must also be taken to assure that the impeller, bearings, and shaft are adequately attached and/or restrained to prevent a lateral or axial shift in these components. PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 Drain X X X X X X X X X CATALOG #37 www.centralfan.com Chem. Spark Resist. Resist. Coat° B† C X X X X X X X X X X X X X X X X X X NOT AVAILABLE See Page 30 for Backward Curve Low static pressure can result in motor overload on blowers designed to operate at higher static pressures. °Coatings described p. 38 Heat Slinger 500°F X X X X X X X X X Disc. Switch X X X X X X X X X (X) Available acces- TYPE C The fan shall be so constructed that a shift of the impeller or shaft will not permit two ferrous parts of the fan to rub or strike. CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 29 ULTRAFAN-PAK BELT DRIVE UTILITY BLOWERS NON-OVERLOADING • Baked epoxy finish standard. • Heavy gauge all welded construction. AIR FOIL CONSTR. STD. FOR SIZE 270 AND LARGER • 250°F max. operating temp. (500°F with heat slinger) • Full class I performance to 5" static pressure…AMCA certified. • Self-aligning pillow block ball bearings with grease fitting (100,000 hrs.) • Available in CW or CCW rotation and eight different discharge positions. (see next page) • Suitable for kitchen hood exhaust, dirt laden air, or where system pressures may vary or are unknown. CW-BH Blower SINGLE PHASE Model No. C D 105 E F D E 122 F G D E 135 F G THREE PHASE 1 Speed 2 Speed 1 Speed 2 Speed HP S M T R 1 ⁄3 1 ⁄2 3 ⁄4 1 1 ⁄2 ⁄4 3 1 11⁄2 1 ⁄2 3 ⁄4 1 11⁄2 3 ⁄4 @1⁄2" S.P. Blower RPM O.V. FPM 1 ⁄2 3 1 ⁄4 1 1 ⁄2 Approx. CFM* Static pressure (inches water) 1 2 21⁄2 3 3 ⁄2 X X X X X X X X X X X X – X X X 2069 2474 2890 3167 2100 2500 3000 3300 1300 1600 1900 2100 1200 1500 1800 2000 1100 1400 1700 1900 900 1300 1600 1800 700 1000 1400 1700 800 1300 1500 1000 1400 X X X X X X X – X X X X X X X X 1744 1964 2187 2484 2300 2700 3000 3500 2000 2300 2600 3000 1800 2200 2500 2900 1700 2100 2400 2800 1400 1900 2200 2600 1200 1600 2000 2500 1300 1700 2300 1500 2100 X X X X X X X – X X X X X X X X 1454 1666 1886 2107 2100 2500 2900 3300 2200 2600 3000 3400 2100 2500 2800 3300 1900 2300 2700 3200 1400 2000 2400 3000 1600 2100 2700 1700 2500 2200 X X – – X X X X X X X X 1490 1652 1900 2106 2400 2700 3200 3600 3100 3500 4100 4600 2800 3200 3900 4400 2600 3000 3700 4200 2100 2600 3300 3900 1700 2200 3000 3500 2600 3300 2000 2900 800 1200 ⁄2 1500 CFM Max. @ 5" 2 HP** 2400 CFM Max. @ 5" 3 HP** 1 1 1 ⁄2 2 F G 165 H J 1 11⁄2 2 3 X X X X X – – – X X X X X X X X 1391 1604 1789 2070 2500 3000 3300 3900 3900 4600 5200 6100 3600 4400 5000 5900 3300 4100 4700 5700 2800 3600 4300 5200 2100 3200 3900 4800 2700 3400 4500 3000 4100 F G 182 H J 1 1 1 ⁄2 2 3 X X X X X – – – X X X X X X X X 1195 1358 1501 1740 2300 2700 3000 3500 4300 5000 5600 6600 3900 4800 5400 6400 3600 4500 5200 6200 3000 3900 4900 5700 3400 4200 5300 3600 4900 3000 4500 G H 200 J K 11⁄2 2 3 5 X X X – – – – – X X X X X X X X 1169 1293 1453 1759 2500 2800 3200 3900 5700 6400 7300 9000 5400 6100 7200 8800 5000 5800 7000 8600 4300 5100 6300 8200 3400 4500 6000 7700 3500 5300 7300 4500 6800 G H 222 J K 11⁄2 2 3 5 X X X – – – – – X X X X X X X X 954 1051 1214 1418 2300 2600 3000 3600 6500 7300 8600 10200 6100 6900 8200 9800 5600 6500 7900 9700 4500 5600 7000 9300 4500 6400 8700 5400 7900 G H 245 J K L 11⁄2 2 3 5 71⁄2 X X X – – – – – – – X X X X X X X X X X 810 897 1035 1233 1419 2100 2400 2800 3400 4000 7300 6600 5900 8300 7700 7200 9800 9300 8900 11900 11500 11100 13900 13500 13000 4500 5900 7700 10300 12300 6600 9500 11600 8800 7600 10800 10000 9300 H J 270 K L 2 3 5 71⁄2 X X – – – – – – X X X X X X X X 936 1046 1261 1448 2100 2400 2900 3400 8800 8000 7400 10000 9600 9200 12300 12000 11300 14300 14000 13600 6300 5000 8100 7100 10600 9500 12900 12000 6200 8800 8100 11000 10500 7300 9600 H J 300 K L 2 3 5 1 7 ⁄2 X X – – – – – – X X X X X X X X 839 980 1177 1328 2100 2500 3100 3500 10800 9600 8700 12900 12000 11000 15800 15100 14200 18000 17600 17000 6700 9400 7400 12900 11400 16000 14200 10300 8500 13300 12600 J K 330 L M 3 5 1 7 ⁄2 10 X – – – – – – – X X X X X X X – 859 1053 1213 1246 2400 3000 3500 3900 15000 18800 21900 24200 10000 14300 12300 17700 16000 20800 19500 10000 8200 14400 13000 18000 16700 3000 CFM Max. @ 5" 5 HP** 2500 3500 CFM Max. @ 5" 5 HP** 3800 4400 CFM Max. @ 5" 5 HP** 3900 5000 CFM Max. @ 5" 5 HP** 6200 6500 CFM Max. @ 5" 7 1⁄2 HP** 7300 6300 7900 CFM Max. @ 5" 10 HP** 9200 CFM Max. @ 5" 10 HP** 12000 CFM Max. @ 5" 15 HP** 10700 14000 CFM Max. @ 5" 15 HP** 15000 *CFM Exhibited is max for HP shown. Each model is capable of higher CFM than shown if equipped with larger motors at higher blower RPM. Note max. motor sizes. **Max. motor size 2-speed switches - page 10. (X) Available models 30 CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 CATALOG #37 www.centralfan.com 5 1800 X X X X 12600 16100 20000 22200 1 4 2000 CFM Max. @ 5" 3 HP** E F 150 G H 13500 17200 21000 23500 4 PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 ULTRAFAN-PAK Max. Disch. CFM* Shutter (75% F.A.) Vib. Isolators Weather Cover Model Access Door Drain Chem. Resist. Coat** Spark Resist.‡ Blower with Motor B C Heat Slinger Disc. Switch Ship Wt. HP 105 122 X X X X X X 1400 1900 X X X X X X X X X X X X X X 100 190 1 11⁄2 135 150 X X X X X X 2300 2800 X X X X X X X X X X X X X X 210 230 11⁄2 2 165 182 X X X X X X 2900 3500 X X X X X X X X X X X X X X 280 350 3 3 200 222 X X X X X X 4300 5200 X X X X X X X X X X X X X X 480 480 5 5 245 270 X X X X X X 6300 7700 X X X X X X X X X X X X X X 620 720 71⁄2 71⁄2 300 330 X X X X X X 9400 9500 X X X X X X X X X X X X X X 820 1100 71⁄2 10 *When centrifugal fan outlet velocities exceed 2000 ft/min. shutters and other fittings should be located at least 21⁄2 duct diameters of straight duct from the blower discharge. Unpredictable shutter performance will result if the shutter is on the blower discharge. Blower performance is enhanced by a properly designed expander (evasé) mounted on the discharge. Shutters ( and other fittings) should be installed downstream of the evasé. **See p. 38 for coatings and pp. 36 and 37 for PVC and FRP blowers. ‡See p. 29 for spark resistant construction. (X) Available accessories Blower Rotation & Discharge Designation (viewed from drive side) Peerless ULTRAFAN-PAK Class I Arr. 10 OUTLET (OUTSIDE) DIMENSIONS Shaft Dia. Size Size Wheel FC BC Dia. CL. 1 8 73⁄4 9 9 105 15 10 ⁄2 101⁄2 11 12 1 3 ⁄4 3 ⁄4 3 ⁄4 3 ⁄4 INLET (OUTSIDE) TH, DB, BH, UB Straight Disch. A B Max. Motor Frame BAU, TAU, TAD, BAD Angular Disch. C D E F H J K L H J K L M N P Q R S 91⁄8 13 81⁄4 53⁄8 141⁄4 71⁄2 6 45⁄8 63⁄4 67⁄8 103⁄8 61⁄4 73⁄8 51⁄4 201⁄8 33⁄4 8 – – 18 181⁄2 103⁄8 13 103⁄4 61⁄2 141⁄4 83⁄8 63⁄4 55⁄8 73⁄4 71⁄8 115⁄8 71⁄2 81⁄4 61⁄8 203⁄4 45⁄16 9 – – 18 181⁄2 3 7 3 1 1 7 5 1 7 3 1 1 5 7 1 T 12 ⁄8 13 11 ⁄4 8 14 ⁄4 10 ⁄4 7 ⁄8 6 ⁄4 9 ⁄8 8 ⁄16 13 ⁄4 8 ⁄8 9 ⁄8 7 ⁄8 19 ⁄8 6 12 ⁄8 – – 20 ⁄2 17 127⁄8 13 113⁄4 8 141⁄4 103⁄4 77⁄8 63⁄4 91⁄8 81⁄16 131⁄4 87⁄8 95⁄8 71⁄8 211⁄2 51⁄8 10 – – 201⁄2 17 95⁄8 237⁄8 63⁄8 131⁄4 111⁄4 123⁄4 251⁄4 20 122 121⁄4 1 163⁄8 131⁄2 131⁄4 95⁄8 131⁄2 143⁄4 101⁄8 81⁄2 111⁄2 101⁄2 165⁄8 103⁄4 121⁄2 135 131⁄2 1 175⁄8 131⁄2 145⁄8 103⁄4 131⁄2 16 111⁄8 93⁄8 125⁄8 113⁄8 181⁄4 117⁄8 133⁄4 10 243⁄8 7 141⁄2 123⁄8 137⁄8 257⁄8 20 150 15 1 191⁄4 151⁄2 161⁄4 113⁄4 151⁄2 175⁄8 123⁄8 103⁄8 141⁄8 123⁄8 201⁄8 131⁄4 151⁄4 111⁄8 267⁄8 71⁄2 161⁄8 133⁄8 147⁄8 275⁄8 22 165 161⁄2 1 213⁄8 15 151⁄2 193⁄4 135⁄8 113⁄8 151⁄2 135⁄8 217⁄8 145⁄8 163⁄4 121⁄4 271⁄2 81⁄2 177⁄8 141⁄2 17 301⁄8 22 1 3 7 173⁄4 13 5 1 1 1 5 1 5 1 1 5 5 18 182 18 ⁄4 1 ⁄16 23 ⁄8 17 19 ⁄8 14 ⁄4 17 ⁄2 21 ⁄2 15 12 ⁄8 17 ⁄8 14 ⁄8 24 ⁄8 16 18 ⁄2 13 ⁄8 30 ⁄8 20 200 20 13⁄16 25 211⁄2 157⁄8 17 233⁄8 161⁄2 133⁄4 183⁄4 153⁄4 263⁄8 175⁄8 203⁄8 147⁄8 311⁄2 22 222 221⁄4 13⁄16 273⁄8 161⁄2 24 173⁄8 17 253⁄4 181⁄4 151⁄4 207⁄8 171⁄4 29 191⁄2 225⁄8 161⁄2 24 245 241⁄2 17⁄16 301⁄4 161⁄2 261⁄4 191⁄4 163⁄4 235⁄8 201⁄8 167⁄8 23 197⁄8 321⁄2 211⁄2 247⁄8 270 27 17⁄16 33 211⁄4 161⁄2 261⁄4 221⁄8 181⁄2 251⁄4 211⁄2 353⁄8 235⁄8 300 30 111⁄16 361⁄4 161⁄2 321⁄4 233⁄8 161⁄2 291⁄2 245⁄8 201⁄2 281⁄8 235⁄8 393⁄8 330 33 111⁄16 391⁄2 213⁄8 353⁄8 257⁄8 215⁄8 331⁄8 271⁄8 221⁄2 307⁄8 255⁄8 43 17 161⁄2 29 1 5 3 1 3 19 ⁄8 15 ⁄4 18 ⁄4 33 ⁄8 25 10 211⁄2 177⁄8 201⁄8 361⁄4 25 323⁄4 105⁄8 237⁄8 193⁄8 225⁄8 393⁄4 26 181⁄4 335⁄8 113⁄4 263⁄8 211⁄4 241⁄2 427⁄8 26 273⁄8 20 345⁄8 125⁄8 29 233⁄4 261⁄2 47 26 263⁄8 301⁄2 221⁄4 36 133⁄4 321⁄4 26 283⁄4 517⁄8 27 287⁄8 331⁄2 243⁄8 413⁄8 15 353⁄8 283⁄8 311⁄8 581⁄8 303⁄8 9 ⁄8 V 7 ⁄16 7 ⁄16 7 ⁄16 7 ⁄16 1 ⁄2 1 ⁄2 1 ⁄2 1 ⁄2 1 ⁄2 1 ⁄2 1 ⁄2 1 ⁄2 1 ⁄2 1 ⁄2 7 ⁄8 X Size 12 145T 12 145T 14 145T 14 145T 17 182T 17 182T 177⁄8 182T 191⁄2 184T 217⁄8 184T 233⁄4 213T 261⁄8 213T 273⁄4 215T 301⁄2 215T 333⁄4 254T 383⁄8 254T NOTE: Letters “C” and “D” are outside housing dimensions. PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 CATALOG #37 www.centralfan.com CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 31 New York General Purpose Blowers BACKWARD CURVE - BELT DRIVE - SINGLE INLET - ARRANGEMENT 10 • FULL AMCA CLASS II CONSTRUCTION— Rugged heavy gauge steel construction for dependable, trouble free heavy duty service. • AIRSTREAM TEMPERATURES TO 650°F— Heat slingers for temperature > 200°F Sizes 12 and 15 require PLR wheel > 200°F • CHOICE OF TWO WHEEL DESIGNS — BOTH STOCKED Acoustafoil-airfoil blade is quieter and more efficient for relatively clean air PLR-flat BC blade for particulate laden air. • STABLE PERFORMANCE FOR VAV SYSTEMS— Acoustafoil wheel yields stable pressure curve from wide open to completely closed off. • Motors are standard ODP See p.10 for special motors CW-TH CW Rotation SEE P.33 FOR BLOWER DIMENSIONS Performance data exhibited are for the acoustafoil wheel and depict typical maximum CFM at designated motor HP. Complete AMCA certified data are available. PLR wheel performance will be different, especially for higher S.P. and corresponding low CFM. Both AcF and PLR models are stocked. Acoustafoil SINGLE PHASE Model No. HP 3 ⁄4 THREE PHASE @ 2" S.P. 1 Speed 2 Speed Blower T R* RPM O.V. FPM – – – – – – 2500 2800 3250 3600 3800 –n 1800 2200 2700 3200 3400 3400 1 Speed S 2 Speed M X – – – – – X X X X X X E F G 123 H J K 1 1 1 ⁄2 2 3 5 X X X X X X F G 153 H J K L 1 1 1 ⁄2 2 3 5 1 7 ⁄2 X X X X X X X – – – – – X X X X X X X X X X – – 1940 2220 2480 2860 2966 –n 1800 2300 2700 3300 3400 3400 G H J 183 K L M 1 ⁄2 2 3 5 1 7 ⁄2 10 1 X X X X X – – – – – – – X X X X X X X X X – – – 1550 1720 2000 2352 –n –n 1800 2200 2800 3400 3400 3400 H J K 223 L M N 2 3 5 1 7 ⁄2 10 15 X X – – – – – – – – – – X X X X X X X X X X – – 1250 1500 1800 2012 –n –n 1700 2300 3000 3400 3400 3400 J K 273 L M N P 3 5 1 7 ⁄2 10 15 20 X – – – – – – – – – – – X X X X X X X X X – – – 1000 1220 1420 1563 –n –n 1800 2500 3100 3400 3400 3400 K L M 303 N P W 5 1 7 ⁄2 10 15 20 25 – – – – – – – – – – – – X X X X X X X X – – – – 1020 1180 1345 1397 –n –n 2200 2800 3300 3400 3400 3400 L M N 333 P W X 7 10 15 20 25 30 – – – – – – – – – – – – X X X X X X X – – – – – 1000 1120 1270 –n –n –n 2500 3000 3400 3400 3400 3400 1 ⁄2 *2 speed - 1 winding See page 10 for special motors and motor controls. 1 1 ⁄2 1 2230 2550 2920 2923 1930 2250 2680 2923 1 ⁄2 1740 2060 2540 2920 2923 MAX. Speed - 4900 RPM 3340 3850 4350 4385 2900 3580 3920 4385 3050 3200 3750 4385 Model AcF Approx. CFM Static Pressure (inches water) 1 2 2 ⁄2 3 4 5 1520 1870 2340 2710 2923 1275 1600 2180 2520 2923 1030 1380 2000 2370 2923 (687) 950 1610 2040 2610 2923 (687) (687) (687) 1200 1700 2385 2923 765 1350 2100 2923 1400 2600 2300 2930 3400 4280 4385 1900 2610 3130 3930 4385 1500 2390 2900 3770 4385 (1031) 1600 2420 3300 4385 (1031) (1031) (1031) 1650 2840 4280 4385 2000 3700 4385 1000 2900 4127 3460 4225 5320 6527 2850 3780 4960 6527 2115 3100 4560 6200 6527 (1535) 1900 3600 5450 6527 (1535) (1535) (1535) 2420 4730 6500 6527 1500 3840 5800 6527 2000 4300 6100 4700 6500 8500 9689 3800 5600 7900 9689 2650 4800 7350 9400 9689 (2279) 3280 5900 8300 9689 (2279) (2279) (2279) 4560 7000 9100 9689 2950 6000 8100 9689 3200 5680 9100 7100 10400 12800 14245 6000 9500 11900 14245 4300 8400 11000 13400 14245 (3351) 3800 9500 12000 14245 (3351) 3355 7000 10400 14000 14245 (3351) (3351) 4800 8200 12550 14245 4180 9150 12700 11200 14000 16900 17600 10000 13000 15700 17600 8400 12000 14800 17600 4750 9400 13000 16600 17600 (4135) 6300 10000 14800 17600 (4135) 4000 7200 13000 16200 17600 (4135) 15800 18000 21300 14000 17200 21300 12700 16000 20050 21300 8700 13000 18000 21300 5500 9200 15400 19000 21300 (5007) 6200 12300 17000 20500 21300 (5007) Max. Speed - 3800 RPM 4980 5620 6500 4570 5280 6100 6527 4150 4800 5680 6527 Max. Speed - 3005 RPM 6950 8500 9689 6300 7880 9650 9689 5600 7000 9100 9689 Max. Speed - 2570 RPM 10850 13000 14245 9500 12000 14245 8700 11000 13700 14245 Max. Speed - 2010 RPM 15000 17600 14000 16400 17600 12700 15000 17600 Max. Speed - 1805 RPM 19000 21300 18000 21000 21300 17000 19800 21300 Max. Speed - 1650 RPM 6 8 7700 12200 15800 6260 11200 16000 19000 (X) Available models ACCESSORIES Set of Vib. Disch. Access Pads Shutter Door X X X X X X Chem. Spark Resist.‡ Resist. Drain Coating* B C X X X X X X X X AcF Model 123 153 Drive Cover X X 183 223 X X X X X X X X X X X X X X 273 303 333 X X X X X X X X X X X X X X X X X X X X X See page 33 for blower dimensions. Solid PVC and FRP blowers pp. 36 and 37. (X) Available accessories 32 CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 Disc. Switch X X Heat Slinger X X Bare Wt. 145 195 X X X X X X 300 425 X X X X X X X X X 645 720 940 *Blower coatings p.38. ‡See p. 29 for description CATALOG #37 www.centralfan.com AMCA Spark Resist Options TYPE B: Blower equipped with Aluminum wheel and shaft ring. (Not suitable for abrasive or 200°F plus. Use Type C.) TYPE C: Blower equipped with non-ferrous inlet cone, non-ferrous rubbing blocks, and ring at housing opening thru which shaft passes. See p. 29 for AMCA spark resist. options. SEE P. 33 FOR AVAILABLE DISCHARGE POSITIONS PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 New York General Purpose Blower BACKWARD CURVE - BELT DRIVE - SINGLE INLET - ARRANGEMENT 10 AVAILABLE FAN DISCHARGES - VIEWED FROM DRIVE SIDE NEW YORK GEN. PURPOSE BLOWER - CLASS 2 -ARR. 10 - PLR WHEEL AND ACOUSTAFOIL WHEEL DIMENSIONS (INCHES) OUTLET INLET OUTLET Model A B C D E F G H J K L M 12 15 18 22 27 30 33 151⁄2 171⁄2 211⁄4 251⁄2 321⁄2 321⁄2 391⁄2 10 12 14 17 201⁄2 221⁄2 241⁄2 123⁄8 151⁄8 181⁄2 221⁄2 271⁄4 303⁄8 333⁄8 133⁄4 167⁄8 201⁄2 247⁄8 301⁄4 331⁄2 367⁄8 77⁄8 93⁄4 113⁄4 143⁄8 173⁄8 193⁄8 211⁄4 13 157⁄8 193⁄8 235⁄8 285⁄8 317⁄8 35 103⁄8 123⁄4 151⁄2 187⁄8 227⁄8 253⁄8 28 313⁄16 365⁄16 3813⁄16 457⁄8 511⁄4 531⁄2 583⁄4 21⁄8 31⁄8 31⁄8 31⁄8 41⁄8 41⁄8 41⁄8 21⁄2 3 31⁄2 4 5 51⁄2 6 131⁄2 161⁄2 20 241⁄2 30 33 361⁄2 93⁄8 113⁄8 137⁄8 167⁄8 203⁄8 225⁄8 247⁄8 Shaft Model R S T V W a b c d Dia. 12 15 18 22 27 30 33 65⁄8 75⁄8 93⁄8 113⁄8 133⁄8 141⁄2 155⁄8 163⁄8 183⁄8 173⁄8 203⁄8 203⁄4 203⁄4 233⁄4 73⁄8 87⁄8 93⁄8 107⁄8 135⁄8 135⁄8 16 61⁄2 8 81⁄4 93⁄4 113⁄4 113⁄4 14 8 91⁄2 101⁄4 113⁄4 143⁄4 143⁄4 17 115⁄8 141⁄8 171⁄4 21 253⁄8 281⁄4 311⁄8 161⁄4 193⁄4 235⁄8 283⁄4 343⁄4 383⁄8 421⁄8 127⁄8 153⁄4 191⁄8 231⁄4 281⁄4 313⁄8 345⁄8 91⁄4 113⁄8 137⁄8 163⁄4 203⁄8 225⁄8 251⁄4 17⁄16 17⁄16 111⁄16 115⁄16 115⁄16 115⁄16 23⁄16 *Approximate shipping weight in lbs. Model no. is approx. wheel dia. Keyway Base holes 3 ⁄8 x 3⁄16 3 ⁄8 x 3⁄16 3 ⁄8 x 3⁄16 1 ⁄2 x 1⁄4 1 ⁄2 x 1⁄4 1 ⁄2 x 1⁄4 1 ⁄2 x 1⁄4 9 ⁄16 9 ⁄16 9 ⁄16 9 ⁄16 3 ⁄4 3 ⁄4 3 ⁄4 N 1915⁄16 2115⁄16 2115⁄16 26 267⁄8 267⁄8 297⁄8 CATALOG #37 www.centralfan.com Q 61⁄8 71⁄4 83⁄4 101⁄4 121⁄2 133⁄8 143⁄4 Maximum motor frame** Bare fan weight* Open TE 145 195 300 425 645 720 940 184T 215T 215T 256T 284T 284T 324T 184T 215T 215T 254T 254T 254T 286T **These maxima can be exceeded on most model sizes. . . with special assembly techniques PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 O 311⁄2 359⁄16 389⁄16 455⁄8 501⁄2 523⁄4 58 CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 Tolerance: ± 1 ⁄8" 33 NEW YORK G.I. BLOWERS GENERAL INDUSTRIAL - BELT DRIVEN - FLAT RADIAL WHEELS INDUSTRIAL AIR-MOVING APPLICATIONS • Dust Collection • Combustion air • Pneumatic Conveying • Heat recovery • Moisture blow-off • Incinerators • Oven and dryer exhaust (NICKELALUMINUM BRONZE) CW-TH LS WHEEL (STEEL) CW-UB Models 144 & Larger Series 20 Arrangement 10 Flat radial-blade design best for material-conveying applications with airstreams containing coarse material or heavy dust and particulate. Models 85, 106, 126 – With nickel-aluminum bronze wheel 180°F Max. temp. (300° with heat slinger) Model 144 & up - With steel wheels Type LS 200°F Max. temp. (600° with heat slinger) Compact Models 85, 106, 126 Arrangement 9 AMCA CERTIFIED AMCA CERTIFIED ASSEMBLED & TESTED- WITH OPEN BALL BEARING MOTOR & ADJUSTABLE SHEAVE DRIVE 1 ⁄4 ⁄3 1 ⁄2 3 ⁄4 1 ⁄2 3 ⁄4 B C 85 D E X X X X 1 D E 106 F G H X X X X X 1 11⁄2 2 3 ⁄4 E F 126 G H J X X X X X 1 11⁄2 2 3 Series 20 3 PHASE 1 SP 2 SP‡ T R 1 PHASE* Model No. X X X X X X X X X X X X X X 1 ⁄4 1 ⁄2 1 2 3 – 3360 3585 4050 330 380 470 556 300 351 465 530 230 310 415 505 145 230 345 465 60 145 270 392 2780 3000 3250 3580 3890 740 880 1000 1200 –n 695 850 1000 1100 –n 640 790 920 1050 1200 520 670 810 970 1100 420 560 700 900 1040 300 500 620 830 960 2400 2520 2830 3000 3300 1140 1270 –n –n –n 1100 1250 1400 –n (Max. Safe 1000 840 700 1160 990 870 1380 1240 1100 1300 –n 1400 RPM = 4000 @ 70°F) 580 750 990 1210 1440 4 6 8 10 –n (Max. safe RPM = 4800 @ 70°F) 60 –n –n –n 220 60 –n –n 345 235 –n –n 60 70 122 (RPM Max. = 4600 @70°F) 300 180 –n 500 350 250 710 575 465 860 750 630 280 490 780 1000 1300 –n 200 600 790 1175 –n –n 360 640 1010 75 90 100 130 Exhibited performance data are condensed. Each blower can be equipped to perform at greater capacity with higher RPM and HP. 3 PHASE 1 SPD S 2 SPD M 1 SPD T 2 SPD‡ R Fan RPM** CFM @ Static Pressure (in. water) 8 10 14 16 2 4 6 F G 144 H J K 1 11⁄2 2 3 5 X X X X X X – – – – X X X X X X X X X – 2000 2110 2360 2510 2870 1120 1460 1710 2100 2500 770 1050 1300 1710 2300 420 774 1035 1440 2050 G H 174 J K L 11⁄2 2 3 5 71⁄2 X X X X X – – – – – X X X X X X X X – – 1680 1751 1900 2150 2400 1750 2150 2660 3400 3800 1200 1520 2140 2850 3600 720 1100 1600 2400 3100 G 194 H J K 1 1 ⁄2 2 3 5 X X – – – – – – X X X X X X X X 1446 1504 1618 1822 1975 2350 2850 3600 1250 1650 2250 3100 700 1100 1700 2600 H J 224 K L M 2 3 5 71⁄2 10 X X – – – – – – – – X X X X X X X X – – 1220 1300 1430 1585 1720 2750 3500 4550 5220 5600 1800 2680 3800 4670 5400 1100 1800 3000 4100 4950 J K 264 L M N 3 5 71⁄2 10 15 X – – – – – – – – – X X X X X X X X – – 1070 1150 1270 1375 1490 3850 5200 6300 7100 8000 2700 3950 5300 6340 7200 1700 3000 4300 5280 6800 2200 3400 4500 6050 K L 294 M N P 5 71⁄2 10 15 20 – – – – – – – – – – X X X X X – – – – – 970 1060 1130 1250 1320 6030 7400 8400 9800 11000 4400 6000 7260 9100 10000 2900 4600 5900 7800 9200 2080 3400 4700 6678 8480 HP Ship Wt. Lbs. CFM @ Static Pressure (in. water) Fan RPM** NOT AVAILABLE HP 1 PHASE* 1 SPD 2 SP S M NOT AVAILABLE Compact Model No. 500 775 1200 1720 635 1250 2050 2750 517 950 1530 518 1200 880 1750 2440 1100 1800 18 22 (Max. RPM @ 70°F = 4600) 180 1020 225 800 430 (Max. RPM @ 70°F = 3745) 235 760 1600 330 1300 750 (Max. RPM @ 70°F = 3114) 600 1250 2100 800 1700 950 1750 2750 3600 1800 2700 1300 2700 3720 5250 1240 2400 3950 2500 3800 5700 7300 2100 3940 5460 365 420 (Max. RPM @ 70°F = 2635) 1120 2300 3350 4200 Ship Wt. Lbs. 1310 2230 1850 920 500 580 (Max. RPM @ 70°F = 2280) 635 1760 3380 720 2860 1736 (Max. RPM @ 70°F = 1995) 890 3180 4700 990 2500 4100 2600 **Fan RPM listed will result in CFM shown @ 4" S.P. Other CFM exhibited are maxima at corresponding S.P. and motor HP, and will require other RPM. ‡ One winding See page 10 for special motors. *120v or 230v 1Ø See page 10 for 208v. 1Ø (X) Available models AMCA Spark Resistant Options ACCESSORIES Model Drive Cover Vib. Isolators Drain Fitting in Housing Bolted Access Door Bare Blower TYPE C Spark Resist. Heat Slinger Chemical Resistant Coating† Inlet Flange◊ Outlet Flange◊ Disc. Swich 85 106 126 X X X X X X X X X X X X X X X * * * X X X X X X – – – – – – X X X 144 174 194 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 224 264 294 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X *Models 85, 106 and 126 are not available as Type C. They are avail. as Type B 34 CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 †See p. 38 for coatings. ◊Welded to housing (X) Available accessories CATALOG #37 www.centralfan.com TYPE B: Blower equipped with non-ferrous wheel and shaft ring. (Not suitable for abrasives or 200°F plus. Use Type C.) TYPE C: A spark-resistant alloy buffer attached to the housing interior adjacent to the wheel front and back and a buffer at the housing shaft opening. Suitable to 600°F w/slinger. (Series 20 only) Dimensions p. 35 PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 NEW YORK GEN. INDUSTRIAL BLOWER ARR. 10 LS WHEEL (STEEL) L, M, & D ARE OUTSIDE DIMENSIONS DIMENSIONS (Inches) OUTLET INLET OUTLET Size A B C D E F G H J K L M N O 144 174 194 224 151⁄2 171⁄2 211⁄4 251⁄2 101⁄2 125⁄8 14 161⁄2 111⁄8 131⁄8 16 187⁄8 81⁄4 101⁄8 101⁄4 13 93⁄8 111⁄8 117⁄8 14 12 141⁄2 18 211⁄4 101⁄4 121⁄4 137⁄8 163⁄8 30 341⁄8 363⁄8 413⁄8 15⁄8 15⁄8 31⁄8 31⁄8 21⁄2 3 31⁄2 4 9 11 11 13 77⁄8 91⁄2 93⁄4 103⁄4 20 22 22 26 197⁄8 217⁄8 337⁄8 387⁄8 264 294 334 364 28 321⁄2 391⁄2 391⁄2 181⁄2 21 23 251⁄2 213⁄4 245⁄8 273⁄8 301⁄4 15 167⁄8 183⁄4 203⁄4 161⁄8 181⁄4 203⁄8 221⁄2 241⁄2 273⁄4 307⁄8 341⁄8 187⁄8 213⁄8 237⁄8 263⁄8 441⁄2 48 531⁄8 56 41⁄8 41⁄8 41⁄8 51⁄4 41⁄2 51⁄2 6 6 15 17 19 21 123⁄8 14 155⁄8 171⁄4 26 267⁄8 297⁄8 30 411⁄2 44 485⁄8 503⁄8 Size Q R S T V W a b c d Shaft diameter 144 174 194 224 – – 6 61⁄2 57⁄8 65⁄8 71⁄4 81⁄4 163⁄8 183⁄8 173⁄8 203⁄8 73⁄8 87⁄8 93⁄8 107⁄8 61⁄2 8 81⁄4 93⁄4 8 91⁄2 101⁄4 113⁄4 103⁄4 131⁄8 15 175⁄8 16 191⁄4 225⁄8 265⁄8 111⁄2 133⁄4 17 20 93⁄4 111⁄2 13 151⁄4 17⁄16 17⁄16 111⁄16 115⁄16 264 294 334 364 77⁄8 85⁄8 93⁄8 101⁄4 93⁄8 101⁄8 11 117⁄8 197⁄8 203⁄4 233⁄4 233⁄4 121⁄4 135⁄8 16 16 11 113⁄4 14 14 13 143⁄4 17 17 201⁄4 23 253⁄4 281⁄2 303⁄8 343⁄8 381⁄8 421⁄8 23 261⁄8 291⁄4 321⁄4 171⁄2 197⁄8 223⁄8 245⁄8 115⁄16 115⁄16 23⁄16 23⁄16 Keyway ⁄8 x 3⁄16 ⁄8 x 3⁄16 3 ⁄8 x 3⁄16 1 ⁄2 x 1⁄4 1 ⁄2 x 1⁄4 1 ⁄2 x 1⁄4 1 ⁄2 x 1⁄4 1 ⁄2 x 1⁄4 Base holes 3 9 3 9 ⁄16 ⁄16 9 ⁄16 9 ⁄16 3 ⁄4 3 ⁄4 3 ⁄4 3 ⁄4 NEW YORK COMPACT G.I. BLOWER NICKEL—ALUMINUM—BRONZE RADIAL WHEEL ARRANGEMENT 9 DIMENSIONS (Inches) OUTLET Model 85 106 126 INLET A B C D* E F G H 101⁄2 101⁄2 121⁄2 6 71⁄2 81⁄2 63⁄8 77⁄8 10 45⁄8 55⁄8 7 53⁄8 65⁄8 71⁄2 67⁄8 81⁄2 111⁄4 57⁄8 71⁄4 83⁄4 17 19 221⁄8 Dimensions should not be used for construction unless certified. PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 OUTLET L* M* N 5 6 8 35⁄8 55⁄8 55⁄8 101⁄4 101⁄4 125⁄8 R 33⁄8 43⁄8 4 **Angular discharge dimensions. CATALOG #37 www.centralfan.com S T U a** b** c** d** Shaft Dia. 6 6 101⁄2 61⁄4 61⁄4 81⁄8 63⁄4 63⁄4 85⁄8 61⁄4 73⁄4 93⁄8 91⁄8 111⁄4 137⁄8 65⁄8 8 105⁄8 55⁄8 63⁄4 81⁄8 1 1 1 See figure above. *D,. L and M are outside dimensions. CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 35 GENERAL-PURPOSE FUME EXHAUSTERS Corrosion-Resistant resin construction for use in severe chemical environments • • • • • • • Fiberglass reinforced plastic construction For severe corrosive fumes and aerosols Efficient backwardly inclined wheel Blower discharge rotatable Standard CW wheel rotation is stock unit Flanged outlet-slip inlet 250°F max. operating temperature • WEATHER/DRIVE COVER STD. STANDARD MOTORS ARE ODP. SINGLE PHASE Model No. C D E GFE12 F G H J D E F GFE15 G H J K E F G GFE18 H J K L M HP 1 ⁄3 ⁄2 ⁄4 1 3 1 11⁄2 2 3 1 ⁄2 3 ⁄4 1 11⁄2 2 3 5 3 ⁄4 1 11⁄2 2 3 5 71⁄2 10 CCW Rotation (special order for CCW units) NOTE: Sizes 24, 30 & 36 are also available with several week lead time. (See page 37 for other plastic blowers.) CW-UB (stock unit) SEE PAGE 10 FOR SPECIAL MOTORS. THREE PHASE @ 1 ⁄2" S.P. CFM 1 Speed S 2 Speed M 1 Speed T 2 Speed R Blower RPM O.V. FPM X X X X X X X X X X – – – – X X X X X X X – X X – – – – 1846 2197 2560 2925 3315 3506 3506 1600 1700 2400 2800 3200 3400 –0 1360 1700 2040 2300 2720 2890 1020 1400 1800 2100 2500 2800 765 1125 1530 1825 2300 2650 2890 850 1275 1600 2100 2450 2720 X X X X X X X X X X – – – – X X X X X X X X X X X – – – 1550 1820 2090 2285 2500 2950 3195 1400 1700 2000 2200 2400 3000 3200 1750 2150 2450 2850 3200 3750 1400 1806 2125 2600 2900 3550 4128 1050 1525 1875 2400 2800 3300 3870 645 1200 1550 2100 2500 3100 3612 X X X X X X X – X X – – – – – – X X X X X X X X X X X X X X – – 1220 1350 1575 1715 1975 2385 2638 2638 1600 1900 2300 2500 2900 3600 4000 –0 3150 3600 4300 4800 5600 6900 2500 3000 3800 4400 5100 6500 7680 1950 2500 3300 4000 4800 6200 7300 (See page 10 for other motors.) Optional set of vibration isolators available. 1 ⁄2 Static Pressure - inches of water 1 11⁄2 2 3 (10" S.P. Max.) 5 6 Approx. Ship Wt. 3800RPM Max @ 70°F 150 4 850 1200 1700 2150 2550 800 1350 1750 2210 950 1400 2040 1100 1700 220 3315 RPM Max. @ 70°F 950 1600 2050 2700 3354 1100 1600 2400 3096 1100 1950 2838 200 600 1550 2322 260 2900 RPM Max. @ 70°F 1920 2880 3500 4400 5850 7000 7680 1900 2650 3750 5150 6450 7296 1800 3000 4600 5900 6912 2300 4000 5400 6528 290 3400 4650 6144 350 (X) Available models ( ) SLIP INLET Tolerance ±1⁄8" O.D. of inlet collar. Slip inlet only 36 Size A• B• C* D 12 15 18 91⁄8 111⁄8 135⁄8 133⁄4 167⁄8 203⁄4 13 16 191⁄2 341⁄8 385⁄8 413⁄4 E 81⁄2 91⁄2 103⁄4 •Inside dimensions *Outside dimensions F G H J K L M N Q 25 28 293⁄8 151⁄2 171⁄2 211⁄4 141⁄4 171⁄8 203⁄8 93⁄4 12 135⁄8 12 145⁄8 16 121⁄4 145⁄8 173⁄8 131⁄8 161⁄8 191⁄2 321⁄2 361⁄2 383⁄4 53⁄4 63⁄4 81⁄4 Shaft Dia. Base holes Bare fan weight Open TE 135 170 240 184T 215T 215T 184T 215T 215T Size R S T V W a b c d 12 15 18 67⁄8 87⁄8 93⁄4 163⁄8 173⁄8 173⁄8 73⁄8 87⁄8 93⁄8 61⁄2 8 81⁄4 8 91⁄2 101⁄4 131⁄2 151⁄2 18 181⁄8 211⁄4 251⁄8 12 14 165⁄8 165⁄8 193⁄4 233⁄4 CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 CATALOG #37 www.centralfan.com 13⁄16 17⁄16 111⁄16 5 ⁄8 5 ⁄8 5 ⁄8 Maximum motor frame PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 Lab Blowers DIRECT DRIVE SEE PP. 36, 38 FOR FRP BELT DRIVEN BLOWERS AND A BRIEF LISTING OF SOME CORROSIVE VAPORS AND PROTECTIVE COATINGS FOR METALS. CCW-UB Model AA, A Lab blowers for corrosion resistance where metal blowers with or without protective coatings prove unsatisfactory. Standard motors are ODP and not exposed to ducted fumes through blower. Max. temp. - 140°F. Model AA - Polypropylene wheel and PVC housing CCW-UB or CCW-TH Model A - Polypropylene wheel and FRP housing CCW rotation - any disch. NOTE: When strong oxidizing acids (nitric, sulfuric, chronic) are present use Model A with PVC wheel PVC wheel is not suitable when vapor phase solvents are present, however. Model AA A HP 1 ⁄6 ⁄3 1 RPM 1725 1725 *1Phase 1 SPD 2 SPD S M X X 3 Phase Motor T Cover 0 X X X X 250 1100 X X DO NOT EXPOSE THESE BLOWERS TO PERCHLORIC ACID. Shp. CFM @ S.P. 1 ⁄2 1 11⁄2 Wt. Lbs. 180 995 800 500 30 50 1 ⁄4 225 1025 (X) Available models *1Ø X.P. models available. Dimensions INLET OUTLET Model A, in. B, in. C, in. D, in. E, in. F, in. G, in. J, in. K, in. AA A 55⁄8 91⁄2 65⁄8 71⁄4 33⁄4 41⁄2 51⁄2 8 9 101⁄2 7 71⁄4 131⁄2 171⁄4 11 151⁄8 41⁄2 8 Belt Drive Industrial PVC Blowers Corrosion Resistant Radial Blade Blower See page 38 for summary of chemical activity *NOTE: SPECIFY CHEMICAL SUBSTANCE & OPERATING TEMP. AMCA CERTIFIED SOLID POLYVINYL CHLORIDE HOUSING • • • • • • • Clockwise Rotation Upblast Discharge ARR. #9 100% corrosion Resistant to most inorganic chemicals* Non-flammable…Self extinguishing Operation to 150°F Electrical Insulator Drain Steel Reinforced Wheel Belt and shaft guard standard See p. 36 for FRP blowers BELT DRIVE WITH TEFC MOTOR* Model No. HP 1 ⁄3 ⁄2 3 ⁄4 C D PVC10 E F G 1 11⁄2 E F PVC14 G H J 1 11⁄2 2 3 F G PVC17 H J K 1 11⁄2 2 3 5 Wheel Dia. 101⁄2 1 3 ⁄4 O.V = CFM 0.196 14 O.V. = CFM 0.349 171⁄2 O.V. = CFM 0.545 Blwr. RPM @ 1" 1 3 Phase Phase S T* DIMENSIONS CFM Static Pressure (inches water) 1 2 3 4 5 6 400 550 700 800 950 300 450 600 700 850 200 350 500 650 800 250 450 550 750 350 500 650 7 Approx. Ship Wt. Lbs. 1829 2157 2390 2632 3013 X X X X X X X X X X 500 650 750 850 1000 1510 1660 1910 2068 2393 X X X X – X X X X X 1050 1200 1450 1600 1900 900 700 500 1050 900 700 550 400 1300 1150 1000 850 700 550 1450 1350 1200 1050 950 800 1750 1650 1550 1400 1300 1000 220 1175 1225 1442 1625 1709 X X X – – X X X X X 1550 1850 2100 2450 2600 1250 1600 1850 2250 2600 260 *See p. 10 for special motors including 2-speed PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 (X) Available models 900 1350 1600 2050 2600 600 1050 800 1350 1100 900 650 1850 1650 1400 1200 2500 2300 2100 1900 175 10 A B C D O.D. E F G J K O.D. L M N P R Max. S Max. T V 1 10 ⁄2 91⁄16 815⁄16 6 4 11 14 17 6 75⁄8 123⁄4 133⁄4 15 181⁄2 141⁄2 93⁄4 13⁄16 Model 14 1 14 ⁄4 12 1015⁄16 8 5 14 16 18 8 99⁄16 143⁄4 16 171⁄4 231⁄2 165⁄16 121⁄2 13⁄16 17 171⁄4 1415⁄16 135⁄8 10 6 17 17 19 10 111⁄8 153⁄4 191⁄2 203⁄4 26 183⁄4 151⁄2 17⁄16 Vibration isolators available CATALOG #37 www.centralfan.com CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 37 Caution: Use these data as a guide only at 70°F. Consult the chemical mfr. for complete data. CHEMICAL RESISTANCE OF POLYVINYL CHLORIDE (PVC) & VINYL ESTER (FRP) PVC provides FAIR-EXCELLENT protection to base metals exposed to the following chemicals at room temperature: Acetic acid (dilute) Alcohol-methyl ethyl Aluminum chloride o Aluminum flouride Aluminum hydroxide Aluminum nitrate Aluminum sulphate Alum Ammonia gas (Dry) Ammonium chloride Ammonium carbonate o Ammonium hydroxide Ammonium nitrate Ammonium sulphate • • • • • • • • • • Aqua regia Barium carbonate Beer Benzoic acid Calcium carbonate Calcium chloride Calcium nitrate Calcium sulphate Caustic Chlorine Chromic acid Citric acid Copper sulphate Crude oil Ethyl alcohol Does not actively corrode bare aluminum • Ethylene glycol Ferric chloride Ferric nitrate Ferric sulphate o Flourine o Formaldehyde o Hydrochloric acid Hydrogen peroxide Hydrogen sulphide Kerosene Lead acetate Magnesium carbonate Magnesium chloride Magnesium sulphate • • • • • • • • • • • • • Mineral oil Naptha Nitric acid (dilute) Nitrous oxide Oxygen Perchloric acid (dilute) Phosphoric acid Photo solutions Plating solutions Propane o Potassium hydroxide Soda ash Sodium chloride Sodium cyanide Sodium hydroxide • • • Sodium nitrate Sodium sulphate Stannous chloride Sulphuric acid (dilute) Tannic acid Trisodium phos. Urea Water-salt Zinc chloride Zinc sulphate o Will attack glass in FRP or Vinyl Ester PVC is ATTACKED to the degree that it does NOT provide adequate protection against the following chemicals at room temperature: • † * o* * * * * o* • • Acetone Alcohol-Amyl, Benzyl Ammonia (liquid) Ammonium flouride Ammonium phosphate Amyl acetate Amyl chloride Aniline • • * * • * * * • Asphalt Benzene Bromine Butane Butyl acetate Carbon tet. Chloroform Creosote Esters Does not actively corrode bare aluminum o o * • * * * * o* * Ethers Ethly acetate Ethylene oxide Formic acid Gasoline Heptane Hexane Hydrogen phosphide Hydroflouric acid Iodine †Use 316 stainless * Use PVDF † Ketones Methyl-Ethyl ketone Methylene chloride * Naphthalene Nitric acid (anhyd.) o* Phenol Phosgene * Propyl alcohol * Sodium bisulphate * Sodium nitrite * Sodium peroxide • • • • * Sodium acetate * Sodium phosphate * Stearic acid Sulphate liquors * Sulphur dioxide (wet) * Toluene o* Trichlorethylene * Turpentine Vinyl acetate * Xylene • • • • • o Will attack glass in FRP or Vinyl Ester Coatings Summary: (Central Fan will apply the following coatings.) PVC-Sprayed, air dryed, multilayer coatings have good-to-excellent resistance to most acids, alkalies and marine exposures. Coatings are flexible, fairly durable, and good to 150°F. The most commonly used protective coating. Unsuitable in most vapor phase organic solvents. Eisenheiss-Synthetic polyester resin which is sprayed, air dryed in multilayer coatings providing tough impermeable coatings good to 150°F. Chemical resistance similar to PVC except notably a slightly better performance when exposed to tricholorethylene, benzene, carbon tet., or gasoline. Does not perform well in hydrogen peroxide. Heresite-A sprayed phenolic resin coating which provides good resistance to most common solvents, organic and inorganic acids. Not recommended for caustics, alkalies, and oxidizing agents. Good to 120°F. Affords fair resistance to methyl ethyl ketone, methylene chloride, trichlorethylene. Epoxy-One of the most durable all-purpose coatings which withstands reasonable abrasion and most chemicals. Baked epoxy-(Factory applied by Peerless on all blowers) effectively protects carbon steel surfaces from normal atmospheric conditions. Is attacked by acids, alkalies, and certain solvents. Can provide effective undercoating. CENTRAL FAN DOES NOT APPLY BAKED EPOXY COATINGS. NOTE: BECAUSE OF THE INHERENT FRAGILITY OF ALL COATINGS, NO EXPLICIT WARRANTY OF SERVICEABILITY CAN BE MADE. BLOWERS: Rigid PVC has good all-around corrosion resistance and is usually the economic material of choice. However, PVC becomes brittle at sub-zero temperatures and loses its strength above 150°F. Thus, steel reinforcement is used in PVC blower wheels. Do not use FRP above 250°F, or PVDF above 180°F. All are spark resistant (electric insulator). Graphite impregnation into FRP can make it conductive to control static electricity. UV radiation (direct sun) will destroy polypropylene. Although slightly more in initial cost, FRP blowers prove to be more economical where the environment is severe and maximum durability is desired. Polyvinylidene (PVDF) will withstand inorganic acids and bases, organic acids, alcohols, aliphatic and aromatic hydrocarbons and halogenated solvents and halogens (except fluorine). 38 CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 CATALOG #37 www.centralfan.com PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 Isolators for Vibration and Noise Control The most effective vibration and noise control is obtained when the isolator deflects up to its maximum limit…without exceeding that maximum deflection. For proper selection: 1. Equipment weight - greater deflection (up to max.) provides maximum isolation 2. Equipment RPM - lower than 1200RPM use springs for maximum isolation (Higher RPM’s use rubber regardless of substructure) 3. Equipment Location(a)Rigid sub-structure-use rubber or springs (b)Flexible sub-structure-use springs (such as on upper levels of building) Model Isolator Color Cap lbs. A RD RD RD RD RD Blue Red Blue Red Black 35 70 135 240 375 .40 .40 .50 .50 .50 B FDS-35 FDS-70 FDS-120 FDS-220 FDS-370 Blue Green Gray Brown Orange 35 70 120 220 370 C FRS-35 FRS-70 FRS-120 FRS-220 FRS-375 Blue Green Gray Brown Orange D SL-35 SL-70 SL-120 SL-220 SL-370 Fig. Max. Defl. In. Spring O.D. Dimensions (in.) A B C D E F .– .– .– .– .– 1.75 1.75 2.37 2.37 2.37 3.13 3.13 3.87 3.87 3.87 .85 .85 1.25 1.25 1.25 5⁄ 16 5⁄ 16 3 ⁄8 3⁄ 8 3⁄ 8 1.25 1.25 1.75 1.75 1.75 2.37 2.37 3.00 3.00 3.00 .34 .34 .34 .34 .34 1.52 1.36 1.18 1.10 1.00 1.75 1.75 1.75 1.75 1.75 2.63 2.63 2.63 2.63 2.63 2.63 2.63 2.63 2.63 2.63 3.50 3.50 3.50 3.50 3.50 .62 .62 .62 .62 .62 3.88 3.88 3.88 3.88 3.88 3⁄ 8 3⁄ 8 3⁄ 8 3⁄ 8 3⁄ 8 .– .– .– .– .– 35 70 120 220 370 1.52 1.36 1.18 1.10 1.00 1.75 1.75 1.75 1.75 1.75 3.0 3.0 3.0 3.0 3.0 4.75 4.75 4.75 4.75 4.75 5.0 5.0 5.0 5.0 5.0 .50 .50 .50 .50 .50 5.0 5.0 5.0 5.0 5.0 3.75 3.75 3.75 3.75 3.75 .44 .44 .44 .44 .44 Blue Green Gray Brown Orange 35 70 120 220 370 1.52 1.36 1.18 1.10 1.00 1.75 1.75 1.75 1.75 1.75 2.12 2.12 2.12 2.12 2.12 6.12 6.12 6.12 6.12 6.12 3.50 3.50 3.50 3.50 3.50 3⁄ 8 3⁄ 8 3⁄ 8 3⁄ 8 3⁄ 8 4.00 4.00 4.00 4.00 4.00 5.63 5.63 5.63 5.63 5.63 .31 .31 .31 .31 .31 RHD-35 RHD-75 RHD-120 RHD-170 Blue Red Green Black 35 75 120 170 .40 .40 .40 .50 .– .– .– .– 2.25 2.25 2.25 3.00 2.0 2.0 2.0 2.25 3.0 3.0 3.0 4.5 .421 .421 .421 .656 1.37 1.37 1.37 1.87 .375 .375 .375 .625 .– .– .– .– F SH-35 SH-70 SH-120 SH-220 SH-370 Blue Green Gray Brown Orange 35 70 120 220 370 1.52 1.36 1.18 1.10 1.00 1.75 1.75 1.75 1.75 1.75 3.69 3.69 3.69 3.69 3.69 2.25 2.25 2.25 2.25 2.25 5.25 5.25 5.25 5.25 5.25 .88 .88 .88 .88 .88 3.00 3.00 3.00 3.00 3.00 .– .– .– .– .– .– .– .– .– .– G SRH-35 SRH-70 SRH-120 SRH-220 SRH-370 Blue Green Gray Brown Orange 35 70 120 220 370 1.55 1.42 1.29 1.30 1.33 1.75 1.75 1.75 1.75 1.75 3.69 3.69 3.69 3.69 3.69 2.25 2.25 2.25 2.25 2.25 7.38 7.38 7.38 7.38 7.38 .75 .75 .75 .75 .75 3.00 3.00 3.00 3.00 3.00 1.48 1.48 1.48 1.48 1.48 .– .– .– .– .– H ARS-30 ARS-70 (For VAV) Boxes 30 70 .50 .50 .– .– 4.75 4.75 2.19 2.19 .50 .50 .27 .27 .– .– .– .– .– .– E 35 70 135 240 375 PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 CATALOG #37 www.centralfan.com CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 G 39 Centrifugal Roof Exhausters Direct Driven • All aluminum construction - compact design • A non-overloading, aluminum wheel • Quiet, vibration free motor mountings • Motor outside exhaust air stream, auto thermal, ODP • Bird screen • Disconnect switch • Galvanized steel frame for strength Roof Model HP 120v 1 Phase 3 Phase 1 Speed Var. Sp. 1 Speed S M T PRN80 2.0 Amps 1 X X(v) – PRN100 3.0 Amps 1 X X(v) – PRN110 3.0 Amps 1 ⁄10 1750 RPM 120v 1Ø XP Motor SX† 12" Ht. Curb Drop-in Shutter . – B9. C1312 ⁄6 HP B12 C1512 B12 C1512 B16 . C2012 B16 C2012 . ⁄10 ⁄10 X X(v) – PRN126 3.0 Amps 1 X X(v) – PRN145 6.3 Amps 1 X X(v) – ⁄4 1 . 1 ⁄6 HP 1 ⁄4 HP . ⁄2 1 ⁄2 HP RPM Sones @ 1⁄4 0 B 9 131⁄4 163⁄8 C 183⁄4 211⁄8 273⁄4 E 37⁄8 47⁄8 1 ⁄8 3 ⁄2 ⁄4 1 328 248 *1550 5.8 4.0 3.0 770 650 520 430 690 550 410 270 610 450 210 520 280 380 11.3 7.6 4.7 1090 910 740 600 990 790 590 420 890 670 400 780 510 650 270 12.0 9.0 6.6 1760 1410 1140 1670 1560 1450 1320 1040 1290 1150 980 800 270 980 790 540 150 14.5 10.7 7.6 2540 2030 1640 2420 2300 2180 2060 1780 1440 1880 1730 1580 1400 920 1460 1270 1030 710 1300 1050 850 *1550 1300 1050 860 *1625 1300 1050 *1625 1300 1050 Shutter O.D. 9 12 16 • 18 gauge galv. steel • fiberglass insulation • neoprene pad • continuous welds • sturdy shutter shelf • self flashing Standard height = 12" (other heights available) Curb O.D. I.D. 121⁄2 91⁄2 1 15 ⁄4 12 20 163⁄4 24 27 210 27 680 43 46 Dimensions Curb Model No. O.D. I.D. C1312 C1512 121⁄2 151⁄4 91⁄4 12 8 10 18 21 C1912 C2012 181⁄2 20 151⁄4 163⁄4 131⁄2 143⁄4 26 31 C2412 C2812 231⁄2 271⁄2 201⁄4 241⁄4 181⁄4 221⁄4 34 39 C3212 C3412 311⁄2 331⁄2 281⁄4 301⁄4 261⁄4 281⁄4 43 46 C3612 C3812 351⁄2 371⁄2 321⁄4 341⁄4 301⁄4 * 48 50 C4012 C4312 391⁄2 43 361⁄4 393⁄4 341⁄4 373⁄4 52 56 C4612 C4912 451⁄2 49 421⁄4 453⁄4 401⁄4 65 69 C5512 C6112 55 61 513⁄4 573⁄4 Ship Wt. M * * * * No shelf CURB ADAPTERS** Model No. Pitched curbs are special order. CURB ADAPTERS • Sturdy…weather tight. • Continuous welds. • 18 ga. galv. steel Adapter permits equal (based on performance) fan replacement without disturbing existing roof curb. **Many other sizes not shown are in stock. CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 3 ⁄4 382 ROOF FAN CURBS AND ADAPTERS 40 1 ⁄8 9.0 DIMENSIONS A 131⁄2 16 21 1 *1550 *Maximum RPM shown obtained with the standard one speed motor. For all other RPMs add solid state speed controller (v) Variable speed w/control. Chemical resistant coating available (X) Available models † Because of 1725 RPM XP motor, the CFM shown will be increased proportionately. Expl. Proof motors are single speed only. Disc. sw. extra (Not installed) See p. 10 Model PRN 80 PRN 100, 110 PRN 126, 145 Ship Wt. lbs. (Fan) CFM Static Press. (in. water) CATALOG #37 www.centralfan.com Dimensions A B CA 1815 CA 1855 CA 1915 18 181⁄2 19 151⁄2 151⁄2 151⁄2 CA 2015 CA 2118 201⁄2 21 151⁄2 181⁄2 CA 2218 CA 2220 22 22 181⁄2 201⁄2 CA 2515 CA 2518 CA 2520 25 25 25 151⁄2 181⁄2 201⁄2 CA 2820 CA 2823 28 28 201⁄2 231⁄2 PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 75 80 CENTRIFUGAL EXHAUSTERS FEATURES • New, quiet, high efficiency PV models • Heavy gauge aluminum housings • Non-overloading aluminum impeller • Performance certified to 2" static press. • Prelubricated, sealed bearings • Motor and drive out of exhaust stream • Bird screen • Welded 18 ga. galv. insulated curb std. curb ht. = 12" See p. 40 for curb detail. ALUMINUM IMPELLER SINGLE PHASE* Model No. PV75 A B A PV100 B C A PV120 B C B PV135 C D C PV150 D E B C PV165 D E F D E PV180 F G D E PV200 F G H D E PV240 F G H HP 1 ⁄6 1 ⁄4 1 ⁄6 1 ⁄4 1 ⁄3 1 ⁄6 1 ⁄4 1 ⁄3 1 ⁄4 1 ⁄3 1 ⁄2 1 ⁄3 1 ⁄2 3 ⁄4 1 ⁄14 ⁄3 1 ⁄2 3 ⁄4 1 1 ⁄2 3 ⁄4 1 11⁄2 1 ⁄2 3 ⁄4 1 1 1 ⁄2 2 1 ⁄2 3 ⁄4 1 1 1 ⁄2 2 3 ⁄4 3 PHASE 1 Speed 2 Speed 1 Speed S M T BELT DRIVEN CFM 2 Speed R 12" Curb Shutter Static Pressure (inches H2O) 1 1 3 1 ⁄4 ⁄2 ⁄4 Fan RPM Sones @ 1⁄4" 0 8.6 10.7 830 940 730 860 620 770 480 660 140 530 11⁄2 X X – X – X – – C2012 B16 1669 1909 X X X – X X – X X – – – C2012 B16 1625 1869 1993 9.1 12.5 14.6 1200 1400 1500 1100 1300 1400 850 1200 1300 550 1000 1200 300 700 1100 600 X X X – X X – X X – – – C2012 1300 1580 1750 7.8 10.9 13.4 1440 1750 1940 1270 1610 1810 1050 1450 1680 730 1270 1520 1020 1345 750 X X X X X X X X X – – X C2012 B16 1480 1616 1823 11.7 13.6 17.1 2000 2200 2500 1800 2000 2300 1600 1800 2200 1200 1600 2000 900 1300 1800 X X X X X X X X X – X X B20 1185 1365 1555 11.2 14.1 17.6 2500 2870 3270 2240 2650 3080 1950 2400 2870 1610 2130 2660 1170 1830 2410 X X X X X X X X X X X X X X X – – X X X B20 975 1074 1244 1456 1584 9.1 11.4 15.7 19.2 21 2700 3000 3400 3900 4200 2200 2500 3000 3600 3900 1700 2100 2700 3300 3700 1100 1600 2300 2900 3400 X X X X X X X – X X X X X X X X B24 830 940 1050 1185 11.7 15.6 19.7 22.0 4340 4920 5490 6200 3800 4440 5060 5800 3080 3920 4600 5430 1930 3100 4030 5010 2020 3250 4440 X X X X X X X X – – X X X X X X X X X X B24 798 904 1000 1133 1250 10.9 13.9 16.7 20 23 4500 5100 5700 6500 7100 3900 4600 5200 6000 6700 2900 3700 4600 5500 6300 1900 3000 3800 5000 5800 1400 2100 3200 4200 5200 X X X X X X X X – – X X X X X X X X X X 657 758 856 977 1033 10.4 13.7 17 21 23 5900 6700 7400 8500 8800 4800 5800 6700 7800 8300 3400 4600 5600 6900 7800 2200 3300 4500 6100 7200 X X – – – X X X X X X X X X X 583 646 749 814 834 15.5 18 21 24 25 8800 9800 11000 12000 –m 7400 5900 8400 7000 10000 8800 11000 10100 11300 10600 4000 5500 7400 9000 9900 X – – – – X X X X X X X X X X 443 515 571 658 731 13 16.1 18.7 23 27 12200 14000 15500 17600 19000 10000 12100 13700 16100 18100 E F PV300 G H J 1 1 1 ⁄2 2 3 X X X X X F G PV365 H J K 1 11⁄2 2 3 5 X X X X – C2412 C2412 C2812 C2812 C3412 C4012 C4612 B16 B30 B36 B42 2 Ship wt. lbs. 85 85 90 93 1300 400 97 111 730 1840 119 112 1800 2600 3200 1600 2400 1600 130 206 2870 227 207 3000 3800 2100 226 254 2400 3300 5000 6500 2600 4600 1000 274 360 3400 6000 7800 9200 5200 7500 3900 418 7500 4600 2700 10000 8200 5200 12000 10000 7900 14600 13000 11400 7300 17200 16200 15300 12800 10000 422 487 *Single phase 120v or 230v. See p. 10 for 208v 1Ø and other special motors. See p. 10 for other special motors. (X) Available models Motor controls p.10 DIMENSIONS 12" CURB SHUTTER PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 Model A B C ID OD PV 75 PV 100 21 21 231⁄2 1 23 ⁄2 233⁄4 3 23 ⁄4 2 2 D 20 20 163⁄4 3 16 ⁄4 16 16 PV 120 PV 135 21 21 263⁄4 263⁄4 291⁄2 291⁄2 2 2 20 20 163⁄4 163⁄4 16 16 PV 150 PV 165 24 24 31 31 35 35 2 2 231⁄2 231⁄2 20 ⁄4 201⁄4 20 20 PV 180 PV 200 28 28 351⁄2 1 35 ⁄2 391⁄2 1 39 ⁄2 2 2 271⁄2 1 27 ⁄2 241⁄4 1 24 ⁄4 24 24 PV 240 34 381⁄2 461⁄2 2 331⁄2 301⁄4 30 PV 300 40 37 53 2 391⁄2 361⁄4 36 PV 365 46 46 64 2 45 CATALOG #37 www.centralfan.com OD 1 ⁄2 1 1 42 ⁄4 42 CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 41 MEETS NATIONAL FIRE PROTECTION ASSOCIATION STANDARD NFPA 96 LISTED CLASSIFICATION YZHW SUBJECT 762 UL ® BELT DRIVE Centrifugal Upblast Ventilators for Commercial Kitchen Exhaust Systems BELT DRIVE Roof and Wall Mounting • UL LISTED • NFPA 96 COMPLIANCE • AMCA CERTIFIED AIR & SOUND• • GREASE COLLECTOR & DRAIN • BIRD SCREEN • ALUMINUM WHEEL & HOUSING • PRELUBRICATED SEALED BEARINGS • EXTERNAL WIRING BOX IF NFPA 96 COMPLIANCE REQUIRED SEE NOTE BELOW Model No. HP 1 ⁄4 ⁄3 1 ⁄2 3 ⁄4 C 1⁄3 D 1⁄2 PNU165RG E 3⁄4 B C PNU135RG D E 1 PHASE‡ 3 PHASE 1 Speed 2 Speed 1 Speed 2 Speed S M T R X X X X X X X X X X X X – – X X F 1 G 11⁄2 X X X X X X X X X –m X X X X X – X X X X D 1⁄2 E 3⁄4 PNU200RG F 1 G 11⁄2 H 2 X X X X X X X X – – X X X X X X X X X X X X – – – X X X X X X X X X X 1 3 ⁄4 E F PNU245RG G H J 1 11⁄2 2 3 X X X X X F G PNU300RG H Roof J Only K 1 11⁄2 2 3 5 X X X X – X – – – – X X X X X X X X X X G H PNU365RG J Roof K Only L 11⁄2 2 3 5 71⁄2 X X X – – – – – – – X X X X X X X X X X ‡1 phase 120v or 230v. Curb 12" Optional Fan 18" Shutter RPM 2012 2230 2565 2950 1774 2016 2380 2790 1527 1788 2187 2630 1282 1578 1992 2455 B24 1120 1287 1480 1632 1771 13.8 17.0 22.0 25.0 27.0 2936 3377 3881 4400 4708 2570 3064 3608 4100 4487 2196 2728 3323 3750 4277 1810 2417 3034 3390 4071 2063 2766 3050 3866 B24 948 1085 1194 1360 1496 14.0 17.2 21.0 26.0 28.0 4414 5052 5560 6328 6966 3746 4406 4924 5698 6332 3285 4064 4666 5548 6263 2664 3574 4216 5145 5897 1724 2994 3742 4752 5532 B30 725 797 913 1005 1150 15.3 17.5 21.0 24.0 27.0 5890 6474 7417 8164 9342 5188 5840 6863 7660 8900 4448 5185 6297 7150 8460 3588 4457 5706 6632 8010 B36 596 692 760 879 987 14.5 17.3 21.0 26.0 31.0 9541 10652 11615 13225 14622 7975 9515 10625 12450 14131 6373 8215 9575 11515 13619 5078 6910 8480 10225 13055 490 548 633 757 813 15.2 17.0 23.0 31.0 35.0 13750 15022 17503 20500 21692 11810 13500 15925 19390 20967 9914 11640 14350 18175 20210 7700 9575 12410 16750 19378 C2818* C2812 C2818* C3412 C3418* C4012 C4018* C4612 B42 C4618* See page 10 for special motors and disconnect switches *NFPA 96 Requires: • Min. curb height 18" (disch. > 40" above roof) Fan-curb hinge assembly to allow cleaning fan and duct 500 FPM min. duct velocity External grease trough Prohibits duct damper (shutter) A B 273⁄8 PNU165 PNU200 PNU245 28 28 34 26 1 31 ⁄2 1 36 ⁄4 1 Curb 1 ⁄6-3⁄4 1-2 3 5 71⁄2-10 Shutter Wall Flange C D OD ID OD OD Flange 221⁄8 231⁄2 201⁄4 20 231⁄2 271⁄2 38 3 39 ⁄4 3 44 ⁄4 3 22 ⁄2 3 28 ⁄4 1 31 ⁄2 1 27 ⁄2 1 27 ⁄2 1 33 ⁄2 1 1 24 ⁄4 1 24 ⁄4 24 24 1 311⁄2 1 311⁄2 1 27 ⁄2 27 ⁄2 1 30 33 ⁄2 371⁄2 1 30 ⁄4 PNU300 40 42 ⁄2 55 ⁄8 34 ⁄4 39 ⁄2 36 ⁄4 36 – – PNU365 46 46 66 411⁄4 451⁄2 421⁄4 42 – – PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 Ship Wt. 120 1320 1960 1500 135 180 2066 2600 3300 2700 215 240 2457 3878 4807 2645 3918 275 290 3510 5060 6074 7556 2289 4780 6570 5346 340 415 5701 7125 9580 12444 8196 11262 9904 530 510 8473 10885 15479 18476 12450 16730 Single Phase HP 331⁄2 1 2 13815 620 Motor Disconnect Switches (PNU245 max. size for wall mtg.) #Requires smaller O.D. curb (PNU245 max. size for hinge kit) 1 882 1333 1810 2290 11⁄2 (X) Available models ACCESSORIES: Curb hinge kit# External grease trough Wall mount flange Dimensions 24 ⁄4 14.5 16.2 17.5 21.0 C2812 Model 0 1 1400 1550 1780 2050 C2418* PNU135 CFM Static Pressure (in. H2O) 3 ⁄2 ⁄4 1 1 B20 C2412 NOTE: • • • • Sones @ 1⁄4" CATALOG #37 www.centralfan.com Three Phase 1 Sp. 2 Sp. 1 Sp. X X X – – X X – – – X X X X X* *460V-550V only 2 Sp. X X X X – (X) Available WALL MOUNT CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 43 Belt Drive Centrifugal Upblast Ventilators Roof and Wall Mounting • • • • • • • • BELT DRIVE Suitable for mounting on roof or wall applications Exhausts air containing odors, fumes, grease etc. Integral trough and drain allow for drainage of liquids Bird screen Pre-lubricated sealed ball bearings Motor and drive assembly out of exhaust air Heavy gauge, aluminum construction - non-overloading wheel Welded 18 ga. galv. Insulated curb (std. 12" high) Special curbs page 40. 1 PHASE* Model No. B C PNU8RF D E HP 1 ⁄4 ⁄3 1 ⁄2 3 ⁄4 1 ⁄4 1 ⁄3 1 ⁄2 3 ⁄4 1 ⁄3 1 ⁄2 3 ⁄4 3 PHASE 1 Speed 2 Speed 1 Speed 2 Speed S M T R X X X X X X X X X X X X – – X X X X X X X X X X X X X X – – X X C D PNU165RF E F 1 G 11⁄2 X X X X X X X X X – X X X X X – X X X X D 1⁄2 E 3⁄4 PNU200RF F 1 G 11⁄2 H 2 X X X X X X X X – – X X X X X X X X X X X X – – – X X X X X X X X X X B C PNU135RF D E 1 3 ⁄4 E F PNU245RF G H J 1 11⁄2 2 3 X X X X X F G PNU300RF H Roof J Only K 1 11⁄2 2 3 5 X X X X – X – – – – X X X X X X X X X X G H PNU365RF J Roof K Only L 11⁄2 2 3 5 71⁄2 X X X – – – – – – – X X X X X X X X X X *1 phase 120v or 230v. (X) Available models 12" Curb CFM Static Pressure (in. H2O) 1 3 ⁄2 ⁄4 1 11⁄2 2 485 540 640 750 440 500 600 720 390 450 525 690 350 415 525 660 225 330 450 590 200 375 530 2012 2230 2585 2950 1774 2016 2380 2790 1527 1788 2187 2630 1282 1578 1992 2455 882 1333 1810 2290 13.8 17.0 22.0 25.0 27.0 2936 3377 3881 4400 4708 2570 3064 3608 4100 4487 2196 2728 3323 3750 4277 1810 2417 3034 3390 4071 2063 2766 3050 3866 948 1085 1194 1360 1496 14.0 17.2 18.2 21.0 24.0 4414 5052 5560 6328 6332 3746 4406 4924 5698 6615 3285 4064 4666 5548 6263 2664 3574 4216 5145 5897 1724 2994 3742 4752 5532 B30 725 797 913 1005 1150 15.3 17.5 21.0 24.0 27.0 5890 6474 7417 8164 9342 5188 5840 6863 7660 8900 4448 5185 6297 7150 8460 3588 4457 5706 6632 8010 3510 5060 6074 7556 B36 596 692 760 879 987 14.5 17.3 21.0 26.0 31.0 9541 10652 11615 13225 14622 7975 9515 10625 12450 14131 6373 8215 9575 11515 13619 5078 6910 8480 10225 13055 490 548 633 757 813 15.2 17.0 23.0 31.0 35.0 13750 15022 17503 20500 21692 11810 13500 15925 19390 20967 9914 11640 14350 18175 20210 7700 9575 12410 16750 19378 Fan RPM Sones @ 1⁄4" 0 B20 2103 2315 2705 3131 11.1 12.6 16.1 19.9 530 600 700 800 B20 1400 1550 1780 2050 14.5 16.2 17.5 21.0 B24 1120 1287 1480 1632 1771 B24 Shutter C2412 C2412 C2812 C2812 C3412 C4012 C4612 B42 1 ⁄4 See page 10 for special motors 44 Dimensions A B C 24 273⁄8 331⁄2 24 273⁄8 331⁄2 28 26 38 28 311⁄2 393⁄4 1 34 36 ⁄4 443⁄4 1 40 42 ⁄2 553⁄8 46 46 66 CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 D 221⁄8 221⁄8 221⁄2 283⁄4 311⁄2 341⁄4 411⁄4 Curb OD ID 231⁄2 201⁄4 231⁄2 201⁄4 1 27 ⁄2 241⁄4 1 27 ⁄2 241⁄4 1 33 ⁄2 301⁄4 1 39 ⁄2 361⁄4 1 45 ⁄2 421⁄4 Ship Wt. 120 140 120 1320 1960 1500 135 180 2066 2600 3300 2700 215 240 2457 3878 4807 2645 3918 275 290 2289 4780 6570 5346 340 415 5701 7125 9580 12444 8196 11262 9904 530 510 8473 10885 15479 18476 12450 16730 13815 620 Motor Disconnect Switches ACCESSORIES: Curb hinge kit (Requires smaller O.D. curb. PNU245 max. size.) External grease trough Wall mount flange (PNU245 max. size for wall mtg.) Chemical resistant coating Model PNU8 PNU135 PNU165 PNU200 PNU245 PNU300 PNU365 KITCHEN EXHAUST FANS NFPA 96 AND UL YZHW #762 PAGES 42,43 Shutter OD 20 20 24 24 30 36 42 CATALOG #37 www.centralfan.com Wall Flange OD Flange 231⁄2 271⁄2 1 23 ⁄2 271⁄2 1 27 ⁄2 311⁄2 1 27 ⁄2 311⁄2 1 33 ⁄2 371⁄2 – – – – Single Phase Three Phase HP 1 Sp. 2 Sp. ⁄6-3⁄4 X X X – – X X – – – 1 1-2 3 5 71⁄2-10 1 Sp. 2 Sp. *460V-550V only WALL MOUNT PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 X X X X X* X X X X – ROOF AIR SUPPLY SIDE INTAKE CONSERVES ENERGY IN MAKE-UP AIR SYSTEMS • Can be located on roof directly over kitchen exhaust hoods, reducing cost of electrical hook-up, expensive insulated interior ducts and fittings. • May also reduce the number of roof penetrations required. FEATURES • Easy on site addition of duct extension* to meet code requirements for supply and exhaust separation • Permanent filters serviceable from exterior of unit. • Blower equipped with ball bearings with an operating temperature range of -65° to +250°F. • Latched top cover provides easy access to blower, motor and drives. • Weather resistant finish of enamel paint on galvanized steel. • Permanent aluminum mesh filters mounted in intake hood (except Model SIS-20) • SIS-20 has large drawer type filter section with screened inlet (not illustrated). • Large filter surface areas for efficient filtering (Intake velocities do not exceed 600 FPM) *Intake duct not supplied Model No. B C D SIS9 E F G HP 1 ⁄4 ⁄3 ⁄2 3 ⁄4 1 1 1 1 1 ⁄2 1 ⁄3 C 1 ⁄2 D 3 SIS10 E ⁄4 F 1 1 G 1 ⁄2 1 D ⁄2 3 E ⁄4 SIS12 F 1 1 G 1 ⁄2 H 2 3 ⁄4 E F 1 1 SIS15 G 1 ⁄2 H 2 J 3 F 1 1 G 1 ⁄2 SIS18 H 2 J 3 K 5 H 2 J 3 SIS20 K 51 L 7 ⁄2 M 10 SINGLE SPEED* 12" 1 Phase 3 Phase S* T Roof Curb X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X – X X – – – X X X X X X X X X X X X X X X X X X X X Static Pressure (inches water)°° Supply° Shutter 1 1 ⁄4" 3 ⁄2" ⁄4" 1 1 ⁄2" 1" CFM RPM HP RPM HP RPM HP RPM C2412 BS18 600 800 1200 1600 1800 2000 577 622 746 901 985 1072 .06 .10 .23 .46 .63 .84 785 809 899 1022 1092 1168 .11 .15 .30 .56 .73 .95 964 968 1032 1139 1200 1265 .16 .21 .38 .66 .85 1.08 1115 1108 1155 1295 1302 1362 C2812 BS22 800 1200 1600 2000 2400 525 600 701 810 925 .08 .18 .33 .58 .93 704 754 828 923 1029 .14 .26 .45 .71 1.09 874 881 945 1023 1118 .20 .34 .55 .85 1.25 C3212 BS26 1600 2000 2400 2800 3000 3400 497 551 614 685 721 792 .21 .34 .52 .77 .92 1.28 633 671 721 775 805 870 .31 .45 .66 .93 1.10 1.48 767 778 816 865 891 945 C3612 BS30 2000 2500 3000 3500 4000 4500 5000 384 409 444 486 533 584 637 .23 .36 .54 .78 1.09 1.50 2.01 508 527 521 577 610 649 692 .37 .53 .73 .99 1.32 1.74 2.25 C3612 BS30 4000 4500 5000 5500 6000 6500 7000 7500 378 402 428 456 485 515 546 578 .65 .85 1.11 1.41 1.77 2.18 2.67 3.22 464 484 505 527 551 576 602 630 C4312 BS37 5000 6000 7000 8000 9000 10000 11000 12000 374 419 464 512 562 614 667 720 .85 1.31 1.90 2.69 3.68 4.91 6.47 8.20 443 482 529 571 616 662 709 758 HP 1 2" 2 ⁄2" RPM HP Ship Wt. RPM HP RPM HP .23 .28 .47 .77 .97 1.21 1346 1367 1377 1439 1483 1536 .36 .45 .65 .98 1.20 1.47 1573 1570 1618 1652 .62 .84 1.21 1.45 1743 1752 1784 .79 1.06 1.46 1013 997 1051 1118 1201 .27 .42 .66 .99 1.42 1299 1231 1234 1293 .41 .60 .87 1.25 1404 1433 1408 .56 .80 1.10 1555 1600 1584 .72 1.00 1.34 .42 .58 .80 1.10 1.27 1.68 884 886 905 945 969 1020 .55 .72 .95 1.26 1.45 1.88 1075 1083 1085 1099 1114 .82 1.04 1.29 1.61 1.81 1233 1245 1252 1.11 1.37 1.67 1371 1386 1.41 1.72 622 623 643 667 691 720 755 .37 .70 .94 1.24 1.58 2.01 2.55 721 717 723 744 769 792 819 .73 .88 1.14 1.48 1.87 2.32 2.86 871 883 878 881 898 922 1.10 1.35 1.58 1.94 2.41 2.95 988 1014 1019 1014 1017 1.46 1.84 2.15 2.47 2.95 1088 1121 1138 1.81 2.30 2.74 200 .93 1.15 1.40 1.72 2.10 2.54 3.05 3.63 537 553 572 592 669 635 658 682 1.22 1.49 1.78 2.10 2.47 2.92 3.44 4.05 620 617 632 650 669 690 711 733 1.60 1.80 2.14 2.52 2.92 3.37 3.89 4.49 780 774 757 756 770 787 806 2.57 2.85 2.97 3.29 3.79 4.36 4.94 893 900 899 883 870 3.29 3.83 4.28 4.72 4.72 987 999 3.97 4.63 345 1.17 1.69 2.36 3.21 4.26 5.53 7.06 8.88 513 539 576 618 663 708 753 799 1.53 2.08 2.80 3.72 4.85 6.19 7.78 9.64 581 597 625 662 704 748 793 1.92 2.50 3.26 4.23 5.41 6.84 8.51 701 710 724 748 780 818 861 3.66 3.45 4.25 5.29 6.57 8.10 9.90 797 812 821 835 857 887 3.66 4.50 5.38 6.45 7.79 9.40 879 899 910 920 934 4.50 5.55 6.60 7.72 9.10 84 110 104 130 140 173 267 387 670 800 *Single phase 120v or 230v Damper spring return. (See p. 8.) °Supply damper is mounted in horizontal plane; opens downward with airflow. See page 10 for special motors All dampers are square. Model No. indicates size - nominal size minus 1⁄8". °°Static pressure reduction on blowers designed for higher pressure could result in motor overload (X) Available models Curb Cap Model SIS9 SIS10 SIS12 SIS15 SIS18 SIS20 Dimensions A* B D E F G H L 243⁄8 283⁄8 323⁄8 363⁄8 363⁄8 443⁄8 193⁄8 213⁄8 245⁄8 283⁄8 421⁄2 49 101⁄4 113⁄8 137⁄16 157⁄8 187⁄8 243⁄4 113⁄16 131⁄8 155⁄8 185⁄8 217⁄8 243⁄4 69⁄32 75⁄8 81⁄16 81⁄2 71⁄4 913⁄16 71⁄16 81⁄2 93⁄8 73⁄4 6 147⁄16 71⁄16 81⁄2 93⁄8 125⁄16 111⁄2 53⁄16 191⁄4 201⁄2 253⁄8 313⁄16 355⁄8 385⁄8 M 169⁄16 189⁄16 219⁄16 2513⁄16 3211⁄16 359⁄16 Z 211⁄4 253⁄4 303⁄4 331⁄2 401⁄4 451⁄2 *Inside dimension PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 CATALOG #37 www.centralfan.com CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 45 Exhaust Relief or Fresh Air Intake Gravity Trimline Ventilators LOW SILHOUETTE • Hood perimeter opening-to-throat area = 2:1 • Inlet velocity at hood opening less than 650 FPM to prevent snow intake • Welded, heavy (.080") aluminum • Bird screen • Optional powered fan supply or exhaust OUTSIDE DIMENSION Dimensions Vent Model 12" High Curb Intake 115v Motorized Shutter A° C E O.D. I.D. Vent Ship Wt. IV 1212 IV 1616 IV 2020 C2012 C2412 C2812 BM15L BM20L BM24L B15 B20 B24 1300 2310 3500 1.0 1.8 2.8 20 24 28 21 28 35 7 9 11 181⁄2 231⁄2 271⁄2 151⁄4 201⁄4 241⁄4 37 46 74 IV 2424 IV 3030 IV 3636 C3212 C3612 C4312 BM28L BM32L BM39L B28 B32 B39 5240 7870 11610 4.0 6.25 9.0 32 38 44 42 53 63 11 13 15 311⁄2 351⁄2 43 281⁄4 323⁄4 393⁄4 79 116 140 Exhaust† Gravity Shutter Supply CFM* .18" S.P. **Throat Area Sq. Ft. Vent 12" Curb *Max. supply for < 650 FPM (snow intake velocity) Max. exhaust. = 1.5X air supply °Outside dimension †Gravity damper will not operate as barometric damper. **Throat dimensions equivalent to model number (X) Available models ROOF FAN CURBS AND ADAPTERS • 18 gauge galv. steel • fiberglass insulation • neoprene pad • continuous welds • sturdy shutter shelf • self flashing Standard height = 12" (other heights available) Pitched curbs are special order. Adapter permits equal (based on performance) fan replacement without disturbing existing roof curb. Many other sizes not shown available. • Sturdy…weather tight • Continuous welds. • 18 ga. galv. Steel. CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 DIMENSIONS M Ship Wt. O.D. I.D. C1312 C1512 121⁄2 151⁄4 91⁄4 12 8 10 18 21 C1912 C2012 181⁄2 20 151⁄4 163⁄4 131⁄2 143⁄4 26 31 C2412 C2812 231⁄2 271⁄2 201⁄4 241⁄4 181⁄4 221⁄4 34 39 C3212 C3412 311⁄2 331⁄2 281⁄4 301⁄4 261⁄4 281⁄4 43 46 C3612 C3812 351⁄2 371⁄2 321⁄4 341⁄4 301⁄4 * 48 50 C4012 C4312 391⁄2 43 361⁄4 393⁄4 341⁄4 373⁄4 52 56 C4612 C4912 451⁄2 49 421⁄4 453⁄4 401⁄4 65 69 C5512 C6112 55 61 513⁄4 573⁄4 * * * 75 80 *No shelf CURB ADAPTERS CURB ADAPTERS 46 Curb Model No. CATALOG #37 www.centralfan.com Dimensions Model No. A B CA 1815 CA 1855 CA 1915 18 181⁄2 19 151⁄2 151⁄2 151⁄2 CA 2015 CA 2118 201⁄2 21 151⁄2 181⁄2 CA 2218 CA 2220 22 22 181⁄2 201⁄2 CA 2515 CA 2518 CA 2520 25 25 25 151⁄2 181⁄2 201⁄2 CA 2820 CA 2823 28 28 201⁄2 231⁄2 PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 Lau Double Inlet Blowers FORWARD CURVE - DOUBLE WIDTH WHEELS - BELT DRIVE Low cost double inlet blowers with double width wheels for those applications not requiring duct to the inlet end. Their compact design and quietness of operation make these blowers popular for residential and commercial heating and air conditioning. Belt driven for flexible choice of speeds and air outputs, with standard motors that are easy and economical to replace if necessary. CLOCKWISE OR CCW ROTATION - (facing motor shaft). Bottom horizontal discharge unless otherwise specified. Discharge position can be easily changed. Long life bronze bearings - Oversized belt drive - True running balanced wheels. Furnished with soft rubber vibration bushings. Use ball bearings for 3/4 HP or greater motor. BARE BLOWER (NO MOTOR DRIVE) Model Wt. No. Lbs A9-6 17 A9-7 19 A9-9 22 A10-6 22 A10-8 23 A10-10 26 A12-6 37 A12-9 39 A12-12* 41 A15-9 50 A15-11 52 A15-15* 65 A18-13 90 A18-18* 100 See p.10 for special motors Assembled & Tested Blower (With motor and drive on blower) Model A B C D E* F* G* H* HP 1Ø 1 Speed 1Ø 2 Speed 3Ø 1 Speed 1 X X X – X X – X X 1 X X X X X X X X X 11⁄2 2 X X – – X X ⁄6 1 ⁄4 1 ⁄3 1 ⁄2 3 ⁄4 *Use ball bearings (X) Available models DIMENSIONS Model Number A A A A A A A A A A A A A A 9-6 ACE 9-7 ACE 9-9 ACE 10-6 ACE 10-8 ACE 10-10 ACE 12-6 ACE 12-9 ACE 12-12 ACE 15-9 ACE 15-11 ACE 15-15 ACE 18-13 ACE 18-18 ACE K 81⁄4 93⁄16 117⁄8 81⁄4 101⁄2 131⁄8 813⁄16 123⁄8 153⁄4 1213⁄16 1411⁄16 185⁄8 173⁄8 217⁄8 E A 101⁄4 101⁄4 101⁄4 113⁄8 113⁄8 113⁄8 137⁄16 137⁄16 137⁄16 157⁄8 157⁄8 157⁄8 187⁄8 187⁄8 157⁄16 157⁄16 157⁄16 171⁄4 171⁄4 171⁄4 207⁄16 207⁄16 207⁄16 241⁄8 241⁄8 241⁄8 293⁄16 293⁄16 B 1415⁄16 1415⁄16 1415⁄16 161⁄2 161⁄2 161⁄2 195⁄16 195⁄16 195⁄16 225⁄8 225⁄8 225⁄8 27 27 Shaft Size ⁄4 ⁄4 ⁄4 3 ⁄4 3 ⁄4 3 ⁄4 3 3 3 1 1 1 1 1 1 1 1 BLOWER PERFORMANCE 1 ⁄4" SP CFM 400 600 800 1000 400 600 800 1000 600 800 1000 1200 1400 400 600 800 1000 1200 1400 600 800 1000 1200 1400 800 1000 1200 1400 1600 1800 600 800 1000 1200 1400 1600 1800 1000 1200 1400 1600 1800 2000 1400 1600 1800 2000 2200 2400 2600 1500 2000 2500 3000 3500 4000 4500 5000 2000 2500 3000 3500 4000 2000 2500 3000 3500 4000 4500 3000 3500 4000 4500 5000 5500 6000 3000 3500 4000 4500 5000 5500 6000 6500 7000 RPM 556 575 630 700 553 586 599 644 566 589 623 663 710 491 500 529 577 635 695 477 492 517 550 586 490 507 529 558 591 635 414 417 439 472 509 542 581 400 410 424 447 470 496 424 436 451 463 486 507 530 347 375 411 458 493 540 589 637 344 368 396 441 479 350 370 395 429 467 505 309 327 352 377 400 427 455 302 315 340 351 367 388 407 423 439 HP .07 .09 .12 .18 .07 .09 .11 .14 .10 .12 .15 .19 .25 .06 .09 .12 .16 .21 .30 .06 .10 .12 .17 .21 .13 .16 .18 .22 .25 .32 .11 .11 .14 .18 .23 .30 .32 .11 .13 .15 .19 .23 .27 .16 .18 .22 .26 .30 .36 .42 .17 .25 .36 .52 .73 1.05 1.37 1.75 .21 .30 .41 .50 .84 .20 .27 .36 .49 .68 .88 .31 .41 .58 .70 .90 1.17 1.33 .28 .36 .48 .61 .74 .90 1.12 1.28 1.50 1 ⁄2" SP RPM 783 769 794 845 807 790 793 813 788 787 803 828 863 704 686 697 724 765 813 700 693 690 727 734 700 693 705 718 739 763 593 577 586 602 623 647 677 566 563 566 575 580 600 574 579 587 596 609 623 638 472 483 503 534 564 605 648 690 459 467 487 512 543 480 488 504 524 552 579 415 423 435 448 463 483 502 414 418 427 437 449 463 476 492 508 HP .11 .13 .16 .22 .09 .13 .16 .19 .14 .16 .20 .25 .32 .11 .13 .16 .21 .29 .38 .11 .14 .17 .23 .28 .20 .21 .26 .29 .34 .40 .18 .19 .22 .27 .32 .37 .43 .18 .21 .23 .27 .31 .37 .26 .29 .32 .37 .42 .47 .54 .24 .34 .46 .62 .87 1.22 1.58 2.05 .30 .40 .53 .73 1.00 .31 .40 .52 .67 .86 1.06 .52 .58 .73 .90 1.10 1.36 1.62 .47 .56 .65 .80 .96 1.13 1.36 1.60 1.87 3 ⁄4" SP RPM 992 950 958 986 986 954 946 954 998 972 964 980 1005 872 841 838 854 880 918 863 836 829 836 847 859 843 841 847 863 883 735 712 708 712 726 744 765 714 697 688 689 695 705 700 702 704 711 718 728 740 582 576 590 608 633 667 703 745 562 563 573 590 611 595 592 598 610 626 647 497 500 506 514 527 541 557 505 503 505 511 521 531 542 556 571 HP .15 .17 .21 .27 .14 .19 .22 .26 .20 .23 .27 .33 .40 .15 .16 .21 .27 .34 .45 .17 .18 .22 .30 .35 .28 .30 .33 .38 .43 .50 .24 .26 .30 .34 .39 .45 .55 .28 .29 .32 .36 .41 .48 .33 .37 .42 .47 .52 .58 .65 .34 .44 .60 .81 1.06 1.42 1.80 2.30 .42 .52 .67 .89 1.17 .45 .55 .67 .83 1.02 1.25 .64 .76 .92 1.11 1.38 1.60 1.89 .61 .71 .83 .99 1.19 1.42 1.67 1.88 2.20 1" SP RPM 1156 1102 1092 1100 1133 1118 1097 1092 1148 1127 1109 1111 1123 1014 983 963 969 989 1017 1013 981 963 958 960 1002 977 967 968 987 991 852 835 812 811 820 832 851 828 815 800 794 791 795 816 809 811 812 817 823 831 666 657 665 680 702 729 761 800 654 652 654 663 679 695 682 679 685 695 712 570 571 576 582 590 599 613 593 585 581 583 589 596 606 616 629 HP .19 .21 .25 .37 .19 .22 .31 .34 .25 .29 .33 .39 .47 .18 .21 .26 .31 .40 .52 .22 .25 .31 .35 .44 .37 .38 .42 .45 .53 .60 .30 .32 .36 .41 .47 .54 .64 .36 .38 .42 .45 .51 .57 .42 .47 .51 .56 .62 .69 .76 .43 .56 .72 .95 1.23 1.55 2.02 2.50 .52 .66 .82 1.05 1.32 .56 .69 .81 .97 1.17 1.44 .76 .94 1.13 1.37 1.54 1.85 2.14 .82 .93 1.06 1.22 1.43 1.66 1.94 2.20 2.52 *Ball bearings std. PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 CATALOG #37 www.centralfan.com CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 47 American Coolair BELT DRIVE UPBLAST AXIAL ROOF FAN • • • • Heavy gauge steel construction with baked epoxy finish Fiberglass butterfly dampers serve as skylight when not in operation Unpainted galvanized steel windband Magnetic latches prevent damper flap when fan is not in operation SPECIAL ORDER MODELS JT AND HS MODEL JBH • JT Model has motor & drive removed from air stream and accessible from roof. • HS model for heat & smoke removal. Continuous operation at 650°F. Intermittent to 1200°F STD. Model JBH Open Motor* Model No. HP 1 Phase S 3 Phase T X X X Model JBH Performances CFM Static pressure (inches H2O) 12" High Curb Fan RPM 0 949 1048 1075 7901 8725 8950 6564 7537 7795 6860 7143 C4312 798 887 965 1113 11780 13094 14245 16430 9724 11255 12559 14969 10279 11692 14234 607 670 725 826 15425 17026 18423 20990 14082 15774 18688 14162 17417 15759 19534 1 3 ⁄4 E JBH24 F G 3 1 11⁄2 X X X F JBH30 G H J 1 11⁄2 2 3 X X X X X X X X F JBH36 G H J 1 11⁄2 2 3 X X X X X X X X C4912 G JBH42 H J 1 1 ⁄2 2 3 X X X X X X C5512 533 579 659 20363 22121 25177 15703 18007 21857 H JBH48 J 2 3 X X X X C6112 469 533 26870 30537 20378 25086 ⁄4 C3812 ⁄8 1 ⁄2 Sones @5' JBH Ship Wt. 31 38 40 240 242 282 26 31 36 48 315 335 340 362 23 27 31 38 367 385 395 412 27 31 38 470 475 500 29 35 620 640 5000† 6489 7700† 10727 13478 9000† 15989 14000† 17737 17000† 21687 † Min. CFM to yield O.V. = 1850 FPM prevents entry of rain during operation. Low speed operation (2-sp. motor) could allow PPT. entry Two speed operation is therefore limited. *Special motors p. 10. (X) Available models Note: Motor and drive assembled and tested on fan panel Fan panel, dampers and windband are separate for ease of handling in shipping and site location. SPECIAL ORDER MODELS JT-HS STANDARD MODEL JBH MODEL JBH DIMENSIONS Model No. A B C D JBH 24 JBH 30 32 38 283⁄4 335⁄8 38 44 32 38 117⁄8 163/4 51⁄8 51⁄8 JBH 36 JBH 42 44 50 335⁄8 381⁄2 50 56 44 50 17 17 JBH 48 56 391⁄2 62 56 17 48 E F MODEL JT Model No. MODEL HS DIMENSIONS Model No. DIMENSIONS A B C D H J JT 24 JT 30 32 38 531⁄4 581⁄4 38 44 301⁄4 361⁄4 28 28 301⁄2 341⁄2 HS 24 HS 30 57 57 51⁄8 51⁄8 JT 36 JT 42 44 50 661⁄8 71 50 56 421⁄4 481⁄2 36 36 415⁄8 451⁄4 HS 36 HS 42 51⁄8 JT 48 56 71 62 545⁄8 36 483⁄4 HS 48 CENTRAL FAN CO., INC. 3890 MYSTIC VALLEY PKWY. MEDFORD, MA 02155 CATALOG #37 www.centralfan.com A B D F 18 18 67 78 14 38 30 14 44 36 SEE MODEL JT 15 50 42 17 56 48 C 88 20 27 62 PHONE: (781) 393-4456 1-800-937-4326 FAX: (781) 396-4581 54 19 20
Similar documents
Die BUCHSTAVIER - Das Dosierte Leben
Das Dosierte Leben Das Avant-Avantgarde-Magazin 16. Jahrgang
More information