Data sheet - hq
Transcription
Data sheet - hq
مؤسسة هيثم قاضي التجارية Hospital and Health Care (healthcare) Facilities Negative Pressure Isolation Rooms Positive Pressure Isolation Rooms All Biological Controls air purification systems and equipment are HEPA filtered and comply with all CDC Guidelines and is FDA 510K certified, mandatory for air purification systems and equipment for use in Hospitals, Health Care (healthcare), and Medical facilities. CDC, OSHA and JCAHO mandate all of the specifications below for use in negative pressure isolation rooms. FDA 510K Certified MANDATORY for use in hospital and heath care facilities in creating a Negative Pressure Isolation Room or a Positive Pressure Isolation Room. FDA Gov site Additional Applications Positive Pressure Isolation Rooms: Greater air pressure in the isolation room than in the adjacent corridor or anteroom. To prevent transmission from the outside environment to profoundly immunosuppressed persons patients (HIV infection). Fungi Spores Examples: Prevention of aspergillosis in bone-marrow transplant recipients. Anthrax, Eryptoccus, Micropolyspora 0114875686 هاتف6896-13321 الرياض، الصحافة، طريق االمام سعود بن فيصل4614 4614 Al Imam Saud Ibn Faysal Rd, As Sahafah, Riyadh 13321 – 6896 Tel: +966 11 487 5686 Info@hq-electro.com www.hq.-electro.com مؤسسة هيثم قاضي التجارية Create a Negative Pressure Isolation Room MICROCON® ExC7 with Germicidal UV Features for a Negative Pressure Isolation Room System Create negative pressure isolation room rooms Create positive pressure isolation room rooms 3 capacity fans 1/5, 1/4, 1/2 HP HEPA filtered Ceiling or shelf mounted Filter replacement from room side Built-in Minihelic pressure gauge Self-contained or isolated fan View of ExC7 from within negative pressure isolation room or positive pressure isolation room. Choice of CFM capacities depending on the size of the negative pressure isolation room and/or positive pressure isolation room Filtered exhaust can be to outside of the isolation room, exhaust, ventilation, ceiling plenums or return air system back into the isolation room One base model w/UV option All equipment units interface with ACCUSTAT® Isolation Room Monitor The MICROCON® Exhaust product line is a series of HEPA filtration systems designed to exhaust controlled amounts of room air to create negative pressure isolation rooms. CDC, OSHA and JCAHO mandate the use of negative pressure isolation rooms for known or suspected TB Tuberculosis patients and today Avian Bird Flu Influenza. Compliance is a matter of hours at a fraction of the cost of engineering controls. Negative Pressure Isolation Room Requirements: Being compliant and meeting "CDC Guidelines: Negative Pressure Isolation Rooms in hospital and healthcare facilities must create at least 12 air changes per hour." Our ExC7 has the appropriate discharge of air outdoors or monitored HEPA highefficiency filtration of room air before the air is returned through the duct work or vented to the outside. The ExC7 can also be installed into a facility's duct work in order to create a permanent Same Isolation Room view with Pre-filtered and HEPA exposed These 12 ACH Air Changes per Hour needs to be accurately monitored (CDC Guidelines) 0114875686 هاتف6896-13321 الرياض، الصحافة، طريق االمام سعود بن فيصل4614 4614 Al Imam Saud Ibn Faysal Rd, As Sahafah, Riyadh 13321 – 6896 Tel: +966 11 487 5686 Info@hq-electro.com www.hq.-electro.com مؤسسة هيثم قاضي التجارية negative pressure isolation room at a more affordable price than a standard room conversion. Negative Pressure Isolation Room Definition: The relative air pressure difference between two areas in a health care facility. An isolation room at negative pressure has a lower pressure than that of adjacent areas, which keeps air from flowing out of the isolation room and into adjacent rooms or areas. Positive Pressure Isolation Room Definition: Greater air pressure in the isolation room than in the adjacent corridor or anteroom. To prevent transmission from the outside environment to profoundly immunosuppressed persons/patients. Recirculation Ventilation in which all or most of the air that is exhausted from an area is returned to the same area or other areas of the facility. Biological Controls' ACCUSTAT™ room pressure monitor is designed specifically for monitoring low negative or positive pressure differentials. Accurate pressurization is a vital step in creating a compliant, controlled and safe environment. Ideally suited for monitoring hospital isolation rooms or pressure differentials in other critical applications. A large lighted digital display readout identifies instantaneous subfractional pressure changes when compared to the adjoining areas. Pressure readings are accurate to within .001” WG with audio and visual alarms identifying unsatisfactory conditions. The ACCUSTAT™ utilizes a highly sensitive pressure transducer eliminating the varying inconsistencies of “airflow” monitors. Air pressure tends to be more consistent and less corrupted by airflow direction disruption, thereby reducing the frequency of false alarms and inconsistent. ExC7 for Negative Pressure Isolation Rooms The ExC7 is a high capacity self-contained HEPA filtered exhaust unit. When placed in a 2x2 drop ceiling grid, it requires only 13" of ceiling clearance. Its fan is housed in a separate enclosure while the ExC7 fan is integrated into the filter housing. This unit is highly recommended for creating hospital negative pressure isolation rooms for TB patients and Avian Bird Flu Influenza H5N1 patients and assistance with preparedness. Positive Isolation Rooms for HIV infection. ExC7 Isolation Room Equipment Blower Box and Diffuser A swing-down stainless steel grille allows easy and safe in-room access to filters for maintenance and replacement. Individual components are connected by 10" or 12" ducting which directs a high volume of filtered air to your choice of exhaust locations. Filtered air can also be returned to the room through a ceiling- mounted diffuser to provide dilution and in-room air changes. A built-in pressure gauge continually monitors the unit's performance. 0114875686 هاتف6896-13321 الرياض، الصحافة، طريق االمام سعود بن فيصل4614 4614 Al Imam Saud Ibn Faysal Rd, As Sahafah, Riyadh 13321 – 6896 Tel: +966 11 487 5686 Info@hq-electro.com www.hq.-electro.com مؤسسة هيثم قاضي التجارية Isolation Room Equipment Built-In Pressure G auge ExC7-UV Isolation Room requiring UV The ExC7-UV is identical to the ExC7, except for the addition of four UV lamps. In applications requiring UV, this configuration improves performance by the addition of HEPA filtration. Four high intensity UV lamps are placed upstream of the filters, virtually eliminating periodic bulb maintenance within the isolation room by preventing particle buildup on the lamps surfaces, thereby cutting down their irradiation effectiveness. Lamps are shielded and a built-in digital hour meter and electronic light sensor bar provide constant bulb performance status. A built-in pressure differential gauge monitors filter performance to assure operation at peak performance levels. This will help keep the isolation room fully compliant. ExC7-UV Isolation Room with view of UV, HEPA & Pre-filter 0114875686 هاتف6896-13321 الرياض، الصحافة، طريق االمام سعود بن فيصل4614 4614 Al Imam Saud Ibn Faysal Rd, As Sahafah, Riyadh 13321 – 6896 Tel: +966 11 487 5686 Info@hq-electro.com www.hq.-electro.com مؤسسة هيثم قاضي التجارية ExC7-UV for in-room irradiation and filtration or creating negative pressure isolation rooms housing TB and Avian Bird Flu Influenza H5N1 patients. EXC7 Sample Configurations for Negative Pressure Rooms Diagram Drawing Picture Photos of Negative Pressure Isolation Rooms - with Design Variations 0114875686 هاتف6896-13321 الرياض، الصحافة، طريق االمام سعود بن فيصل4614 4614 Al Imam Saud Ibn Faysal Rd, As Sahafah, Riyadh 13321 – 6896 Tel: +966 11 487 5686 Info@hq-electro.com www.hq.-electro.com مؤسسة هيثم قاضي التجارية 2 Models Available Building Management System Specs Part Number Blower Type Bearing Type Volts FLA Amps HP/Speed Elec. Protection Free Air CFM Delivered CFM RPM Service MountPosition Oper. Temp FM Interface Facility Elec Interface Fuse/Breaker Hangers Chassis Duct Collars Weight Dimensions Agency Blower Module 1/4 HP Blower Module 1/2 HP EXC7 BM 1.25 (115V) Or EXC7 BM 2.25 (230V) EXC7 BM 1.5 (115V) Or EXC7 BM 2.25 (230V) PSC Direct Drive Fwd Curve Perm. Lub Ball 115V or 230v ,50/60Hz 1Ph 3.66A@115V,1.8@230v 1/4 HP, single speed Auto-Reset Thermal Overload 990 CFM 500 CFM 1080 Maintenance Free ALL POSITIONS -20º to 104º F Cable & Chassis Connector Included 2X4” Elec Box Included PSC Direct Drive Fwd Curve Perm. Lub Ball 115V or 230v ,50/60Hz 1Ph 3.66A@115V,1.8@230v 1/2 HP, single speed Auto-Reset Thermal Overload 1202 CFM 800 CFM 1390 Maintenance Free ALL POSITIONS -20º to 104º F Cable & Chassis Connector Included 2X4” Elec Box Included 10A Circuit Breaker 4 Eye-Hooks 20ga Galvz Steel, Powder Coat Paint 12”Diam x 2”high 2ea-In and Out 49 LBS 18”x17”x15” (W x L x H) FDA Approval 10A Circuit Breaker 4 Eye-Hooks 20ga Galvz Steel, Powder Coat Paint 12”Diam x 2”high 2ea-In and Out 36 LBS 18”x17”x15” (W x L x H) FDA Approval 0114875686 هاتف6896-13321 الرياض، الصحافة، طريق االمام سعود بن فيصل4614 4614 Al Imam Saud Ibn Faysal Rd, As Sahafah, Riyadh 13321 – 6896 Tel: +966 11 487 5686 Info@hq-electro.com www.hq.-electro.com