Aqu@Fan II

Transcription

Aqu@Fan II
Engineering Data Manual
eration
New : New gen
Aqu@Fan II
Fan Coil Units
Models AWC, AWN, AHC, AHN
EC1 motor
Quality, efficiency and reliability, built into every unit...
Vertical console units with
cabinet, AWC type
Support feet supplied as optional
AWC vertical console units are designed for use in three different types of
installation :
- as a wall hung console in areas where a skirting board prevents the use of a
floor mounted console ;
- as a floor console with optional front air intake RF (most frequently located
below a large window) ;
- as a floor console with support feet and bottom air intake.
They feature a modern decorative style cabinet with matching plastic discharge
grille, providing a high performance unit that is attractive and durable which will
complement any room decor.
The AWC models can be fitted, as optional, with electromechanical or electronic
Aqu@Net control, with valve kits, etc.
Vertical concealed units without
cabinet, AWN type
AWN vertical chassis only units are designed for applications that require a
fully concealed or a fully recessed installation.
These units include all the features of the AWC vertical console unit type
except that only the chassis is supplied instead of decorative style cabinet.
Like the AWC units, Aqu@Net control (except the remote control) as well
as other electromechanical controls and valve kits can be fitted, as optional,
on unit.
Units can be fitted with optional feet (supplied loose), if floor mounting is
required.
Ceiling exposed units with
cabinet, AHC type
AHC ceiling exposed units are designed for ceiling mounting in areas where
it is necessary to conserve floor space.
They contain all the features of the AWC unit within the decorative style
cabinet with matching plastic discharge grille.
Standard version is designed for rear horizontal air intake without inlet
grille.
Similar to the previous models, the Aqu@Net control can be supplied, as
optional, on AHC units with remote control. Other optional controls and
valve kits are also available.
Bottom air intake grille supplied as optional
Ceiling concealed units without
cabinet, AHN type
AHN ceiling chassis units are designed for concealed or recessed ceiling
installations. This unit consists of the AHC basic unit horizontally installed.
AHN units contain all the features of the AHC ceiling exposed units except
that only the chassis casing is supplied instead of the decorative style
cabinet.
Possibility of supplying separately an optional Aqu@Net type remote control
for wall mounting. Other optional controls and valve kits are also available.
Auxiliary drain pan supplied as optional
2
New range of fan coil units Aqu@Fan II : "Innovation for an optimum comfort"
Easy to install, improvement in sound levels and performances, Aqu@Net
electronic control, etc., are the key developments carried on our fan coil units.
Moreover, the new technology of the fan motor assembly, through the use of
optimized centrifugal impellers, associated with a 5-speed motor enables
all Aqu@Fan II models to reach an average decrease in sound levels of
- 4dBA, compared with the previous range, offering therefore a maximum
acoustical comfort.
The Aqu@Fan II fan coil unit range is issued from that development striving
to meet customers’ wishes and advices.
Aesthetic of the grille, associated with the casing refined finish allows a
harmonious and smart integration of the fan coil units Aqu@Fan II in all
types of interiors.
Aqu@Fan II range is provided with an electronic control : Aqu@Net, whose
ergonomic and discrete remote command can be loose or fitted on the fan
coil unit.
They are the ideal solution to air condition agreeably and efficiently, flats,
hotels, hospitals, offices and other premises, all year long.
All settings being made at factory, no needs to be done by installer.
The Aqu@Fan II fan coil units range includes 7 sizes with air flows ranging
from 140 thru 1400 m3/h, for cooling capacities of 2 thru 9 kW.
This control, especially innovating, offers as standard a master/slave
function up to 15 units from one single remote control.
The Aqu@Fan II fan coil units are equipped with optimized coils to bring the
best possible performances in 2-pipe, 4-pipe, or 2-pipe/2-wire versions.
Other features like window contact, occupied/unoccupied, antifreeze modes
are integrated without involving any price add.
Design features
For the 2-pipe/2-wire systems, the electric heating coil is composed of
heating rod type resistances mounted inside the coil (at the place of hot
water tubes).
Cabinet
All units are manufactured from heavy-gauge zinc coated sheet steel for long
life and durability. Oven baked powder epoxy paint insures a good protection
and an attractive finish for all outside panels (Standard colour : RAL 9003).
Note : The water connection side is defined left-hand or right-hand when
observer is looking at the unit from the discharge side.
The standard discharge grille is made of "ABS" plastic and has a different
colour from the cabinet (standard colour : Pantone 427C).
Fan and motor assembly
On the versions with optional front intake, monobloc grille, painted in RAL
9003, is mounted flush to the cabinet. Grille can be removed by releasing the
two quarter turn fixing screws to get access to the filter.
The units are fitted with a fan-motor assembly of which the fan is composed
of double inlet forward curved centrifugal wheel(s) dynamically balanced and
specially designed for an optimal air flow and a low noise level.
Casing
The Aqu@Fan II range can be supplied with 2 types of motor :
-The standard AC motor of asynchrone direct drive type having 5 speeds,
3 of them are factory pre-wired, equipped with a built-in normally closed
thermal protection of automatic reset type.
Made of galvanized steel insulated with closed cell polyethylene foam. Casing
has 4 slotted lugs on its rear side which allow the unit to be easily and quickly
installed at site, in wall or ceiling mounting.
-The EC1 motor of high efficiency and low electrical consumption type
for a significant energy saving. The motor is suitable for 0-10 V input,
ensuring variable speed capability. It is fitted with ECospeed3 interface
card (supplied as standard) for a 3-speed optimized running. Available on
sizes 20-30-40-50-60.
Access to all internal components of the unit is facilitated by an easy
dismounting of the casing.
Condensate drain pan is fabricated from galvanized sheet steel coated with
closed cell polyethylene foam on external face. The drain pan is painted to
insure the anticorrosion protection.
Power supply : 230 V±10%/1 Ph/50 Hz - 60 Hz (50 Hz on size 70).
All models are equipped with an inclined condensate drain pan to ensure
optimal condensate draining and to minimize water retention.
Electrical connections
Units are supplied complete with internal electrical wiring terminating in a
junction block protected by a cap or the cabinet.
Moreover, models 20 to 70 are also equipped with a V-shape pan in order to
allow either vertical or horizontal installation.
Cabinet internal space allows installation of optional control systems supplied
by manufacturer or others.
Coils
When the optional Aqu@Net control is fitted on the unit, the controller
includes a junction block for power supply connection and incorporates, as
standard, a cable clamp.
Made of staggered copper tubes, mechanically expanded into high efficiency
hydrophilic aluminium fins, assuring maximum heat transfer efficiency.
Each fan coil unit is equipped with a 3-row cooling coil plus 1 row optional
heating coil.
Filter
On model 80, the 4-pipe and 2-pipe/2-wire coils are supplied in one finned
block. On models 20 to 70, the 4-pipe and 2-pipe/2-wire coils are additionnal
to the 2-pipe coil.
Easily removable cleanable filter having fire class M1 and G2 efficiency. Filter
media is mounted on a metallic frame.
Options
Each coil is supplied with headers having air vent at the highest point and
drain plug at the lowest point. The water connection of each header is 1/2"
gas female threaded type.
Many different options and accessories are available for all units : see chapter
"Mounting accessories". Controls are shown in the corresponding chapter.
Models designation
Aqu@Fan II fan coil unit
A W N 40. 30 E 1500
W : vertical wall unit
H : horizontal ceiling unit
E : electric heating coil with capacity in Watts
Hot water coil : 0 without coil - 1 with 1 row
C : model with cabinet N : model without cabinet
Chilled water coil : 3 with 3 rows
Sizes : 20, 30, 40, 50, 60, 70, 80
3
Energy performance of Aqu@Fan II with new generation EC1 motor
Energy class
More efficient
Size 20
Models
2030
2031
FCEER
FCCOP
Size 30
Models
3030
3031
FCEER
FCCOP
Less efficient
Size 40
Models
4030
4031
FCEER
FCCOP
Size 50
Models
5030
5031
FCEER
FCCOP
Size 60
Models
6030
6031
FCEER
FCCOP
Energy savings
Electrical consumption with EC1 motor (in Watts)
Models
Size 20
Size 30
Size 40
Size 50
Size 60
V1
14
28
23
32
47
V2
13
18
14
17
36
V3
7
13
10
14
23
V4
6
10
8
8
19
V5
4
7
6
7
13
Without control consumption, static pressure 0 Pa.
3-speed control interface for EC1 motor
Aqu@Net
Interface card
3 speeds
EC1 motor
0 to 10 V
ECoSpeed3
4
EC1, EC and AC motor absorbed power comparison
Aqu@Fan II size 20
50
45
AC motor
40
Pabs (W)
35
30
EC motor
25
20
15
10
EC1 motor
5
0
0
50
100
150
200
250
300
350
Qv (m /h)
3
Aqu@Fan II size 30
70
60
AC motor
50
Pabs (W)
40
EC motor
30
20
10
EC1 motor
0
0
100
200
300
400
500
Qv (m3/h)
Aqu@Fan II size 40
60
AC motor
50
Pabs (W)
40
EC motor
30
20
10
EC1 motor
0
0
100
200
300
Qv (m3/h)
5
400
500
600
EC1, EC and AC motor absorbed power comparison (continued)
Aqu@Fan II size 50
70
AC motor
60
Pabs (W)
50
40
EC motor
30
20
EC1 motor
10
0
0
200
400
600
800
Qv (m3/h)
Aqu@Fan II size 60
120
100
AC motor
Pabs (W)
80
60
EC motor
40
20
EC1 motor
0
0
200
400
600
800
1000
Qv (m3/h)
Operating range with EC1 motor : Voltage setpoint
Models
Minimum starting voltage
(V)
Minimum voltage with electric heater
(V)
Maximum optimized voltage
(V)
20
1.5
1.7
5.5
30
1.5
3.1
8.2
40
1.5
2.4
6.6
50
1.5
2.8
7.6
60
1.5
4.4
9.0
6
Aqu@Fan II AWC Models - Mounting Accessories
Options and accessories
STD
standard version for wall mounting (no support feet supplied).
MP
support feet for floor mounting.
MPG
air intake grille between feet.
RF
front air intake grille (no support feet supplied).
RP
back partial air intake with support feet.
RT
back full air intake with support feet.
RC
floor air intake with support feet.
RVCA-RT
air intake arrangement with motorized (non controlled) on/off damper (back or front intake).
RVCA-RC
air intake arrangement with motorized (non controlled) on/off damper (floor or front intake).
RVCM-RT
air intake arrangement with manual damper (back or/and front intake).
RVCM-RC
air intake arrangement with manual damper (floor or/and front intake).
TMT
telescopic wall sleeve.
TMTG
telescopic wall sleeve with external grille (filter not supplied).
RH
cabinet backwrap for plinth.
ALV
finished back panel (for unit mounted in front of glass wall).
BAC
auxiliary drain pan (for units without motorized valves).
FLOOR FIX
floor fixing brackets (for MP and ALV).
STD
MP/MPG
RC
TMTG
RVCA-RC *
RVCM-RT *
RF
RP *
RT
RVCA-RT *
RVCM-RC *
* Can be fitted with optional intake grille between feet.
7
RH *
ALV *
Aqu@Fan II AWN Models - Mounting Accessories
Options and accessories
STD
standard version for wall mounting (no support feet supplied).
MP
support feet for floor mounting.
RD
front air intake.
RP
back partial air intake with support feet.
RT
back full air intake with support feet.
RC
floor air intake with support feet.
RVCA-RT
air intake arrangement with motorized (non controlled) on/off damper (back or front intake).
RVCA-RC
air intake arrangement with motorized (non controlled) on/off damper (floor or front intake).
RVCM-RT
air intake arrangement with manual damper (back or/and front intake).
RVCM-RC
air intake arrangement with manual damper (floor or/and front intake).
TMT
telescopic wall sleeve.
TMTG
telescopic wall sleeve with external grille (filter not supplied).
BAC
auxiliary drain pan (for units without motorized valves).
CRG
discharge duct collar.
STD
MP
RP
RT
RVCA-RC
RVCM-RC
RC
RVCA-RT
RVCM-RT
TMTG
8
RD
CRG
Aqu@Fan II AHC Models - Mounting Accessories
Options and accessories
STD
standard ceiling mounted version with rear air intake (no inlet grille).
RF
bottom air intake grille.
RVCA-RC
air intake arrangement with motorized (non controlled) on/off damper.
RVCM-RC
air intake arrangement with manual damper.
RC
rear air intake with support feet.
MP
support feet.
MPG
air intake grille between feet.
THI
return air perforated panel with filter media.
TMT
telescopic wall sleeve.
TMTG
telescopic wall sleeve with external grille (filter not supplied).
BAC
auxiliary painted drain pan (for units without motorized valves).
std
thi
rvca-rc/rvcm-rc
rf
mp/mpg
rc
tmtg
Aqu@Fan II AHN Models - Mounting Accessories
Options and accessories
STD
standard ceiling mounted version with rear air intake (no inlet grille).
RVCA-RC
air intake arrangement with motorized (non controlled) on/off damper.
RVCM-RC
air intake arrangement with manual damper.
RD
bottom air intake.
RC
rear air intake with support feet.
CRG
discharge duct collar.
TMT
telescopic wall sleeve.
TMTG
telescopic wall sleeve with external grille (filter not supplied).
BAC
auxiliary painted drain pan (for units without motorized valves).
std
CRG
RC
TMTG
9
RD
RVCA-RC/RVCM-RC
Aqu@Fan II - Available Options
Coils
AWC
AWN
AHC
AHN
XX30
3 row main coil - 2 pipe system
Yes
Yes
Yes
Yes
XX31
3 row main coil + 1-row additional coil - 4 pipe system
Yes
Yes
Yes
Yes
XX30E
3 row main coil + standard electric heating coil - 2 pipe / 2 wire system
Yes
Yes
Yes
Yes
Note : XX = size of unit (for example : 2030 = fan coil size 20 with 3-row main coil - 2 pipe system).
2-way control valve - 2-pipe system - 230 Volt thermal actuator
1 valve, 2-way type - For 2-pipe system on cooling or heating coil
W2G1
Valve
Thermal attenuator 230 V - 50/60 Hz
Sizes
KV
Ø
T max amb
T max fluid
Id (A)
In (A)
P (VA)
20/60
1.6
1/2"
50 °C
110 °C
0.6
0.013
3.0
70/80
2.5
3/4"
50 °C
110 °C
0.6
0.013
3.0
2-way control valve - 4-pipe system - 230 Volt thermal actuator
W2G2
2 valves. 2-way type - For 4-pipe system on cooling and heating coils
Cooling valve
Heating valve
Thermal actuator(s) 230 V - 50/60 Hz
Sizes
KV
Ø
KV
Ø
T max amb
T max fluid
Id (A)
In (A)
P (VA)
20/60
1.6
1/2"
1.6
1/2"
50 °C
110 °C
0.6
0.013
3.0
70/80
2.5
3/4"
1.6
1/2"
50 °C
110 °C
0.6
0.013
3.0
4-way control valve - 2-pipe system - 230 Volt thermal actuator
1 valve. 4-way type - For 2-pipe system on cooling or heating coil
W4G1
Valve
Thermal actuator 230 V - 50/60 Hz
Sizes
KV
Ø
T max amb
T max fluid
Id (A)
In (A)
P (VA)
20/60
1.6
1/2"
50 °C
110 °C
0.6
0.013
3.0
70/80
2.5
3/4"
50 °C
110 °C
0.6
0.013
3.0
4-way control valve - 4-pipe system - 230 Volt thermal actuator
W4G2
2 valves. 4-way type - For 4-pipe system on cooling and heating coils
Cooling valve
Heating valve
Thermal actuator(s) 230 V - 50/60 Hz
Sizes
KV
Ø
KV
Ø
T max amb
T max fluid
Id (A)
In (A)
P (VA)
20/60
1.6
1/2"
1.6
1/2"
50 °C
110 °C
0.6
0.013
3.0
70/80
2.5
3/4"
1.6
1/2"
50 °C
110 °C
0.6
0.013
3.0
10
Aqu@Fan II - Main Controls (Optional)
CMV (supplied fitted)
Manual fan speed selector
TBV (supplied fitted)
Electromechanical control with valve
2
✔
AWC
1
3
AWC
✔
AWN
✔
AHC
✔
AHN
✘
4
AWN
✔
AHC
✔
AHN
✘
5
P1 P3
4
3
1
2
5
1
Heat
LS
MS
P1
P3 P1
M
N (Blue)
LS
MS
HS
Extra speeds
Cool
HS
N (Blue)
Extra speeds
0
V
M
1 2 3
N Ph
1 2 3
G
N Ph
230V/1Ph/50Hz
G
230V/1Ph/50Hz

Action on valve and fan, 2-pipe system in heating or cooling mode.

Set of thermostat + 4-position manual speed selector : OFF/LS/MS/HS.

Option TBV1 for action on valve only with constant fan operation.

For reversible 2-pipe system with summer/winter automatic changeover, possibility of mounting
with a water changeover sensor PCO, use of 4-way valve is mandatory.

4 position manual fan speed selector : OFF/LS/MS/HS.
TBMV (supplied fitted)
Electromechanical control with valve(s)
2
1
3
AWC
✔
AWN
✔
AHC
✔
AHN
✘
4
2
5
1
4
LS
MS
HS
N (Blue)
Extra speeds
5
2
P1
SD
1
3
M
Cool
6
Heat
P3 P1
HV
CV
1 2
N Ph
G
230V/1Ph/50Hz

Action on valves and fan, 4-pipe, 2-pipe/2-wire or manual changeover 2-pipe system.

Set of thermostat + summer/winter switch + 4-position manual speed selector: OFF/LS/MS/HS.

Option TBMV1 for action on valve(s) only with constant fan operation.

For 4-pipe or manual changeover 2-pipe system, possibility of mounting a low temperature cut-out sensor SD (temp. range 45 °C/35 °C) on hot water piping to stop fan operation.
11
Aqu@Fan II - Main Controls (Optional) (continued)
CMVM (supplied loose)
Manual fan speed selector
TRM-FA (supplied loose)
Electromechanical remote control
Extra speeds
AWC
✔
AWN
✔
M
HS
MS
LS
Ground
M
✔
Neutral/Blue
1 2 3 4 5 6 M
1
Power supply
220-240/1/50
2
3
HV
LS
AHN
CV
MS
✔
HS
AHC
Yellow/Green
Yellow/Green
Neutral/Blue
Extra speeds
4
5
6
7
8
M
GROUND
NEUTRAL
GROUND
1N230V~
PHASE
L
L
AWC
✔
AWN
✔
AHC
✔
AHN
✔
NEUTRAL
PHASE
N
0/I
L
TRM
CMVM

Wall mounted remote thermostat to control valves and fan.

Suitable for 4-pipe (with cooling and heating valves), 2-pipe/2-wire (with cooling valve and
electric heater), 2-pipe (with cooling or heating valve) and reversible 2-pipe (with manual
changeover) systems.

Control buttons : ON/OFF; Summer/Winter changeover; Manual fan speed selector : LS/MS/HS.

4 position manual fan speed selector : OFF/LS/MS/HS.
TRM-VP (supplied loose)
Electromechanical remote control
TAE20 (supplied loose)
Electronic remote thermostat
M
AWC
✔
AWN
✔
AHC
✔
AHN
✔
Extra speeds
CV
20
HV
4
Neutral/Blue
1
2
3
5
3
30
4
5
6
7
8
M
AWC
✔
AWN
✔
AHC
✔
AHN
✔
L
N
3
2
1
3
2
1
1
2
3
4
5
6
7
8
NEUTRAL
9 10
M
PHASE
N
CF
5
LS
MS
4
GROUND
1N230V~
25
10
HS
Yellow/Green
15
SEH
CV
HV
L
TRM
Ph N
G
230V/1Ph/50Hz

Adjustable dead zone electronic thermostat with summer/winter automatic changeover.

Wall mounted remote thermostat to regulate control valve(s).

Suitable for 4-pipe (with cooling and heating valves), 2-pipe/2-wire (with cooling valve and

Suitable for 4-pipe (with cooling and heating valves), 2-pipe/2-wire (with cooling valve and
electric heater (TAE 20BE)), 2-pipe (with cooling or heating valve) or reversible 2-pipe (with or
electric heater), 2-pipe (with cooling or heating valve) and reversible 2-pipe (with manual
without extra electric heating, 4-way valve mandatory and SEH changeover sensor) system.
changeover) systems.

Controls buttons : ON/OFF, manual fan speed selector : LS/MS/HS, NO (normally open) or NC

Control buttons : ON/OFF; Summer/Winter changeover; Manual fan speed selector : LS/MS/HS.
(normally closed) window contact CF.
12
Aqu@Fan II - Main Controls (Optional) (continued)
Aqu@Net communicating electronic control
FCC electronic controller (supplied fitted)
RCL wire remote control with digital display (supplied loose or fitted)
POWER SUPPLYY
230V/1Ph/50Hz
R2
CV
RED LS
Pump
VL1
✔
AHC
✔
AHN
✔
J1
F/M
BLACK HS
AWN
VL2
F/L
VIOLET MS
SR
F/H
UNOC
NIU
M
N
VL1 N
VL2 N
BROWN
✔
GROUND
to the casing
EH2 N
BLUE
AWC
L
F/N
EH2
EH1
EH1 N
NEUTRAL BLUE
LT
Pump N
R1
HV
YELLOW/GREEN
RED
WIN
RED
ALARM
RAT
4
3
2
BLACK
BLACK
WPT
WPT
1

Controller can be configured in 2-pipe heating only or cooling only, 2-pipe/2-wire, reversible 
Wire remote control for wall mounting or for mounting on AWC units.
2-pipe with or without extra electric heating or 4-pipe system.

Keyboard with locking device and buttons : ON/Standby; fan operation (auto or manual);
operation mode (cooling, heating, auto or fan operation only); temperature setpoint

Other pre-programmed functionalities included : master/slaves up to 15 units controlled from
adjustment in different modes.
one remote control only; NC window contact; automatic or manual selection of unoccupied

Functioning LED.
mode; antifreeze mode.
Aqu@Net communicating electronic control
System networking
µBMS programmable supervision station (supplied loose)
°C
Wed
AUTO
UNIT
TEMP
MODE
NIGHT
PROG
SET
HOUR
SWING
LOCAL
UNIT
+
DAY
CLEAR
µBMS
Minisupervision
station
TEMP
Bus RS485
MODE
NIGHT
PROG
SET
HOUR
SWING
LOCAL
UNIT
up to
100 units
+
CLEAR
DAY
FCC
controller
NIU board
up to
100 units
RCL
wire remote control

In association with FCC controllers through a communication bus and interface board (NIU),
µBMS allows 15 different zones with 100 units to be managed.

RS485 communication bus system allowing user to monitor 100 fan coil units through a

Other functionalities included either in global or individual control by zone :
supervision station (µBMS), with FCC Aqu@Net controllers fitted with interface boards (NIU)
- Daily and weekly programming of running times (2 hour ranges),
and with local controls (RCL).
- Programming and setting of temperature setpoints (cooling, heating, auto),
Max. length of bus = 1000 meters, shielded twisted pair cable.
- Choice of operation mode (cooling, heating, auto or fan operation only),
- Choice of fan operation speed (auto or manual).
13
Aqu@Fan II - Technical Data
Air flow - 3-row dry coil
Speeds
V1
V2
V3
V4
V5
2030
317
282
223
178
132
3030
407
350
290
253
181
4030
570
470
385
352
295
5030
736
554
471
359
333
6030
917
770
650
593
468
7030
1150
1070
799
656
545
8030
1376
1069
934
793
665
Electrical data 230 V/1 Ph/50 Hz (standard motor)
Unit sizes
V1
Max. running absorbed power (W)
Max. absorbed current (A)
20
30
40
50
60
70
80
45
60
57
66
107
150
188
V2
37
49
47
50
81
130
132
V3
27
40
39
45
64
110
112
V4
19
33
36
40
55
101
101
V5
16
24
33
39
41
92
90
0,17
0,28
0,27
0,31
0,5
0,7
0,95
Note : Data compatible with 60 Hz, except size 70.
Water volume (liters)
Sizes
20
30
40
50
60
70
80
Water volume (liters)
1-row (Heating)
0.24
0.34
0.43
0.52
0.61
0.69
0.92
3-row (Cooling)
0.62
0.90
1.18
1.46
1.73
2.19
2.60
Operating limits
Environmental conditions
Water circuit
Minimum premise air temperature / new air intake / around the apparatus
Maximale premise air temperature / new air intake / around the apparatus
Max. operating pressure
Min. entering water temperature
Max. entering water temperature
14
5 °C / 15% RH
32 °C / 70% RH
17 bars
+5 °C
+90 °C
Aqu@Fan II - Optional Electric Heating Coil Data
Electric heaters with heating rods supplied fitted
BE1
BE2
20
300
600
30
300
600
40
500
1000
50
600
1200
60
750
1500
70
750
1500
80
900
1800
BE3
BE4
900 (1)
(300+600)
900 (1)
(300+600)
1500 (1)
(500+1000)
1800 (1)
(600+1200)
2250 (1)
(750+1500)
2250 (1)
(750+1500)
2700 (1)
(900+1800)
1200 (1)
(600+600)
2000 (1)
(1000+1000)
2400 (1)
(1200+1200)
3000 (1)
(1500+1500)
3000 (1)
(1500+1500)
3600 (1)
(1800+1800)
BE3
BE4
NA
(1) Available in 2 steps suitable for Aqu@Net control.
NA : Not available.
Electric heaters with heating rods supplied loose
BE1
BE2
20
300
600
30
300
600
40
500
1000
50
600
1200
60
750
1500
70
750
1500
900 (1)
(300+600)
900 (1)
(300+600)
1500 (1)
(500+1000)
1800 (1)
(600+1200)
2250 (1)
(750+1500)
2250 (1)
(750+1500)
(1) Available in 2 steps suitable for Aqu@Net control.
NA : Not available.
15
NA
1200 (1)
(600+600)
2000 (1)
(1000+1000)
2400 (1)
(1200+1200)
3000 (1)
(1500+1500)
3000 (1)
(1500+1500)
Performance Data Aqu@Fan II - 2-pipe System
3-row main coil
Sizes
2030
3030
4030
5030
6030
7030
8030
Cooling
Heating
Speeds
Humid
air flow
(m3/h)
Pt
(W)
Ps
(W)
WPD
(kPa)
Pc
(W)
WPD
(kPa)
V1
V2
V3
V4
V5
V1
V2
V3
V4
V5
V1
V2
V3
V4
V5
V1
V2
V3
V4
V5
V1
V2
V3
V4
V5
V1
V2
V3
V4
V5
V1
V2
V3
V4
V5
292
259
205
164
121
374
322
267
233
167
524
432
354
324
271
677
510
433
330
306
844
708
598
546
431
1058
984
735
604
501
1266
983
859
730
612
1.87
1.75
1.47
1.26
1.04
2.44
2.28
2.13
1.92
1.52
3.46
3.08
2.62
2.47
2.19
4.22
3.17
2.8
2.24
2.10
5.73
4.94
4.39
4.08
3.40
7.21
6.84
5.61
4.81
3.92
9.04
7.59
6.65
5.68
4.75
1.48
1.35
1.11
0.93
0.75
1.94
1.73
1.56
1.39
1.02
2.73
2.35
1.97
1.83
1.60
2.98
2.20
1.92
1.52
1.42
3.85
3.27
2.86
2.64
2.22
5.64
5.17
4.17
3.56
2.89
6.89
5.62
4.92
4.19
3.51
8.00
7.00
5.00
4.00
3.00
16.0
15.0
12.0
10.0
7.00
33.0
26.0
20.0
18.0
14.0
29.0
17.0
14.0
9.00
8.00
42.0
32.0
26.0
23.0
16.0
25.0
22.0
16.0
12.0
8.00
39.0
29.0
23.0
17.0
12.0
2.53
2.39
2.02
1.65
1.24
3.40
3.02
2.61
2.29
1.74
4.57
4.18
3.50
3.23
2.69
5.41
4.26
3.71
3.05
2.83
7.36
6.18
5.25
4.85
3.99
9.18
8.41
6.90
6.01
4.94
11.3
9.27
8.36
7.11
5.99
8.00
7.00
5.00
4.00
3.00
13.0
12.0
11.0
9.00
6.00
28.0
22.0
17.0
15.0
12.0
24.0
15.0
12.0
8.00
7.00
35.0
27.0
22.0
19.0
14.0
21.0
19.0
13.0
12.0
7.00
33.0
24.0
19.0
14.0
10.0
Performances based on :
Summer : air 27 °C/19 °C (wet bulb) and chilled water 7/12 °C.
Winter : air 20 °C, entering water température 50 °C, water flow identical to cooling mode.
Pt : Total cooling capacity.
Ps : Sensible cooling capacity.
Pc : Heating capacity.
WPD : Water pressure drop.
Standard wiring of the 3 speeds. Other speed combinations available upon request.
16
Performance Data Aqu@Fan II - 4-pipe System
3-row cooling main coil + 1-row heating complementary coil
Sizes
2031
3031
4031
5031
6031
7031
8031
Cooling
Heating
Speeds
Humid
air flow
(m3/h)
Pt
(W)
Ps
(W)
WPD
(kPa)
Pc
(W)
WPD
(kPa)
V1
V2
V3
V4
V5
V1
V2
V3
V4
V5
V1
V2
V3
V4
V5
V1
V2
V3
V4
V5
V1
V2
V3
V4
V5
V1
V2
V3
V4
V5
V1
V2
V3
V4
V5
282
251
199
158
118
362
312
259
225
161
508
419
343
314
263
656
493
420
320
297
817
685
579
528
417
1024
953
712
584
486
1226
952
832
707
592
1.97
1.85
1.54
1.33
1.08
2.39
2.20
2.08
1.87
1.48
3.40
3.01
2.56
2.41
2.13
4.22
3.68
3.25
2.59
2.43
5.61
4.84
4.29
3.98
3.31
7.12
6.68
5.47
4.69
3.81
8.83
7.40
6.49
5.54
4.63
1.52
1.39
1.14
0.95
0.76
1.88
1.65
1.52
1.35
0.99
2.66
2.29
1.92
1.78
1.55
3.00
2.71
2.37
1.88
1.74
3.77
3.20
2.80
2.58
2.17
5.54
5.04
4.06
3.46
2.81
6.71
5.46
4.78
4.08
3.41
42.0
37.0
27.0
20.0
14.0
15.0
14.0
12.0
10.0
7.00
31.0
25.0
19.0
17.0
14.0
20.5
16.0
13.0
9.00
8.00
40.0
31.0
25.0
22.0
16.0
24.0
21.0
15.0
11.0
8.00
38.0
28.0
22.0
16.0
12.0
2.32
2.23
1.98
1.71
1.39
3.34
3.10
2.80
2.58
2.16
4.54
4.23
3.73
3.52
3.21
5.25
4.51
4.01
3.43
3.23
6.06
5.55
5.11
4.86
4.18
6.98
6.26
5.27
4.96
4.28
11.6
10.3
9.43
8.14
6.75
6.00
5.00
4.00
3.00
2.00
13.0
11.0
9.00
8.00
6.00
25.0
22.0
17.0
16.0
13.0
50.0
38.0
32.0
23.0
21.0
15.0
13.0
11.0
10.0
8.00
24.0
19.0
15.0
12.0
9.00
48.0
38.0
33.0
25.0
18.0
Performances based on :
Summer : air 27 °C/19 °C (wet bulb) and chilled water 7/12 °C.
Winter : air 20 °C, hot water 70/60 °C.
Pt : Total cooling capacity.
Ps : Sensible cooling capacity.
Pc : Heating capacity.
WPD : Water pressure drop.
Standard wiring of the 3 speeds. Other speed combinations available upon request.
17
Aqu@Fan II - Sound Data
AWC/AHC
Sizes
2030
3030
4030
5030
6030
7030
8030
Speeds
Lw global
(dBA)
Lp* global
(dBA)
V1
V2
V3
V4
V5
V1
V2
V3
V4
V5
V1
V2
V3
V4
V5
V1
V2
V3
V4
V5
V1
V2
V3
V4
V5
V1
V2
V3
V4
V5
V1
V2
V3
V4
V5
53
49
43
36
34
56
52
48
45
37
52
47
42
40
37
55
48
45
39
37
61
56
52
49
43
65
61
54
50
46
66
59
56
53
49
45
41
35
28
26
48
44
40
37
29
44
39
34
32
29
47
40
37
31
29
53
48
44
41
35
57
53
46
43
38
58
51
48
45
41
AWN
NR*
Lw global
(dBA)
Lp* global
(dBA)
41
37
31
24
22
44
40
36
33
24
39
35
29
27
24
43
37
33
27
23
48
44
39
36
31
52
48
41
38
34
54
48
44
41
36
53
49
45
38
34
56
52
48
45
37
52
47
42
40
37
55
48
45
39
37
61
56
52
49
43
65
61
56
50
48
66
59
56
53
49
43
39
35
28
24
46
42
38
35
27
42
37
32
30
27
45
38
35
29
27
51
46
42
39
33
55
51
46
40
38
56
49
46
43
39
AHN
NR*
Lw global
(dBA)
Lp** global
(dBA)
NR**
39
35
30
23
19
42
38
34
31
22
37
33
27
25
22
41
35
31
25
23
46
42
37
34
29
50
46
41
35
34
52
46
42
39
34
53
49
45
38
34
56
52
48
45
37
52
47
42
40
37
55
48
45
39
37
61
56
52
49
43
65
61
56
50
48
66
59
56
53
49
32
28
24
17
<15
35
31
27
24
16
31
26
21
19
16
34
27
24
18
16
40
35
31
28
22
44
40
35
29
27
45
38
35
32
28
28
24
19
<15
<15
31
27
23
20
<15
26
22
16
<15
<15
30
24
20
<15
<15
35
31
26
23
18
39
35
30
24
23
41
35
31
28
23
(*) The sound pressure levels Lp are based on (NR) characteristic of a room having volume of 100 m 3 with reverberation time of 0.5 seconds and at a
distance of 1 meter.
(**) Informative data, considering a sound attenuation of the room and installation of 21 dB.
18
Aqu@Fan II - Sound Data (continued)
AWC/AHC
Sizes
2031
3031
4031
5031
6031
7031
8031
Speeds
Lw global
(dBA)
Lp* global
(dBA)
V1
V2
V3
V4
V5
V1
V2
V3
V4
V5
V1
V2
V3
V4
V5
V1
V2
V3
V4
V5
V1
V2
V3
V4
V5
V1
V2
V3
V4
V5
V1
V2
V3
V4
V5
53
50
44
37
35
56
52
49
45
41
52
47
42
40
37
55
48
45
39
37
62
58
55
51
47
65
61
56
51
47
66
59
57
54
49
45
42
36
29
27
48
44
41
37
33
44
39
34
32
29
47
40
37
31
29
54
50
47
43
39
57
53
48
43
39
58
51
49
46
41
AWN
NR*
Lw global
(dBA)
Lp* global
(dBA)
41
37
32
25
23
44
40
37
33
28
39
35
30
27
24
43
37
33
27
24
49
45
42
38
34
52
48
43
38
35
54
48
45
42
36
53
50
44
37
35
56
52
49
45
39
52
47
42
40
37
55
48
45
39
37
62
58
55
51
47
65
61
56
51
47
66
59
57
54
49
43
40
34
27
25
46
42
39
35
29
42
37
32
30
27
45
38
35
29
27
52
48
45
41
37
55
51
46
41
37
56
49
47
44
39
AHN
NR*
Lw global
(dBA)
Lp** global
(dBA)
NR**
39
36
29
22
20
42
38
35
31
24
37
33
27
25
22
41
35
31
25
23
47
44
40
36
33
50
46
41
36
33
52
46
43
40
34
53
50
44
37
35
56
52
49
45
41
52
47
42
40
37
55
48
45
39
37
62
58
55
51
47
65
61
56
51
47
66
59
57
54
49
32
29
23
16
<15
35
31
28
24
20
31
26
21
19
16
34
27
24
18
16
41
37
34
30
26
44
40
35
30
26
45
38
36
33
28
28
24
19
<15
<15
31
27
24
20
<15
26
22
17
<15
<15
30
24
20
<15
<15
36
32
29
25
21
39
35
30
25
22
41
35
32
29
23
(*) The sound pressure levels Lp are based on (NR) characteristic of a room having volume of 100 m3 with reverberation time of 0.5 seconds and at a
distance of 1 meter.
(**) Informative data, considering a sound attenuation of the room and installation of 21 dB.
19
Dimensional Data - Aqu@Fan II AWC Models
horizontal discharge grille
A
231
204
73
170
90
B
100
Auxiliary condensate drain pan and support feet supplied as optional
wall mounting
rightleft
220
C
Discharge
2
TOP
1
M8 fixing screws
4 x 8 mm
D
4
4
3
2
3
1
H G
I
J
BOTTOM
I
J
F
Return
L
K
G H
E
100
220
L
K
M
N
M
N
100
Ground level
Ground level
1
2
3
4
100
Ground level
: auxiliary coil water inlet
: auxiliary coil water outlet
: main coil water inlet
: main coil water outlet
Models
A
B
C
D
E
F
G
H
I
J
K
L
M
N
Weight
20
768
478
500
430
360
150
408
390
256
236
52
95
141
183
20
30
953
478
685
430
360
150
408
390
256
236
52
95
141
183
23
40
1138
478
870
430
360
150
408
390
256
236
52
95
141
183
30
50
1323
478
1055
430
360
150
408
390
256
236
52
95
141
183
35
60
1508
478
1240
430
360
150
408
390
256
236
52
95
141
183
39
70
1323
578
1055
530
365
157
506
492
289
233
41
88
145
172
42
80
1508
578
1240
530
365
157
500
489
245
234
40
83
143
186
50
Dimensions are in millimeters ; weight in kilograms.
20
Dimensional Data - Aqu@Fan II AWN Models
front view - left hand connections
wall mounting
C
A
70
15
15
Discharge
TOP
Auxiliary condensate drain pan
(Option)
M8 fixing screws
4 x 8 mm
Electrical side
protection cap
105
B
D
E
F
BOTTOM
40
100
Ground level
Return
100
top view - left hand connections
Ground level
rightleft
Auxiliary condensate drain pan (Option)
Electrical side protection cap
220
K’
220
2
105
1
70
A
G
16 mm OD condensate outlet
4
3
H
I
K’
220
L
K
Auxiliary condensate
drain pan
L
K
4
2
1
3
H
J
J
top view - discharge duct connections
G
I
108 108
M
N
100
M
N
Ground level
100
Q
O
15
P
15
1
2
3
4
A
: auxiliary coil water inlet
: auxiliary coil water outlet
: main coil water inlet
: main coil water outlet
Models
A
B
C
D
E
F
G
H
I
J
K
K'
L
M
N
O
P
Q
Weight
20
510
430
500
430
360
150
408
390
256
236
52
3
95
141
183
130
-
11.5
14
30
695
430
685
430
360
150
408
390
256
236
52
3
95
141
183
130
-
11.5
16
40
880
430
870
430
360
150
408
390
256
236
52
3
95
141
183
130
-
11.5
23
50
1065
430
1055
430
360
150
408
390
256
236
52
3
95
141
183
130
-
11.5
27
60
1250
430
1240
430
360
150
408
390
256
236
52
3
95
141
183
130
-
11.5
30
70
1065
530
1055
530
365
157
506
492
289
233
41
3
88
145
172
130
-
12.2
34
80
1250
530
1240
530
365
157
500
489
245
234
40
0
83
143
186
136
20
12.2
41
Dimensions are in millimeters ; weight in kilograms.
21
Dimensional Data - Aqu@Fan II AHC Models
bottom view
ceiling mounting
Discharge
C
A
Auxiliary condensate
pan (optional)
Discharge
M8 fixing screws
Main condensate pan
16 mm OD condensate outlet
D
B
E
F
Return
90
170
Return
left hand water connections
side view
Auxiliary condensate
pan (optional)
16 mm OD
condensate outlet
Auxiliary
condensate pan (optional)
16 mm OD
condensate outlet
4
1
220
2
3
2
3
231
K L
204
4
N M
K’
1
B
J
I
Models
20
30
40
50
60
70
80
A
768
953
1138
1323
1508
1323
1508
: auxiliary coil water inlet
: auxiliary coil water outlet
: main coil water inlet
: main coil water outlet
B
478
478
478
478
478
578
578
C
500
685
870
1055
1240
1055
1240
D
430
430
430
430
430
530
530
204
1
2
3
4
E
360
360
360
360
360
365
365
F
150
150
150
150
150
157
157
G
408
408
408
408
408
506
500
H
390
390
390
390
390
492
489
Dimensions are in millimeters ; weight in kilograms.
22
I
256
256
256
256
256
289
245
J
236
236
236
236
236
233
234
K
52
52
52
52
52
41
40
K'
3
3
3
3
3
3
0
L
95
95
95
95
95
88
83
M
141
141
141
141
141
145
143
N
183
183
183
183
183
172
186
231
discharge view
H
G
Weight
20
23
30
35
39
42
50
Dimensional Data - Aqu@Fan II AHN Models
bottom view - left hand water connections
145
C
70
A
Auxiliary condensate
pan (optional)
ceiling mounting
Discharge
Main condensate pan
M8 fixing screws
D
D
E
F
16 mm OD
condensate outlet
Electrical side
protection side
Return
discharge view
left hand water connections
A
15
15
Auxiliary
condensate
pan
(optional)
Auxiliary
condensate pan (optional)
16 mm OD
condensate outlet
Electrical side protection cap
220
Main condensate
pan
4
145
N M
70
O
220
2
3
K’
K L
1
discharge duct connections
J
I
H
G
S
P
Q
R
15
15
A
1
2
3
4
70
Caution ! Do not fix duct to edge of condensate drain pan, in order to allow pan removal.
Models
A
C
D
E
F
G
H
I
J
K
K'
L
: auxiliary coil water inlet
: auxiliary coil water outlet
: main coil water inlet
: main coil water outlet
M
N
O
P
Q
R
S
Weight
20
510
500
430
360
150
408
390
256
236
52
3
95
141
183
723
11.5
130
21
72
14
30
695
685
430
360
150
408
390
256
236
52
3
95
141
183
908
11.5
130
21
72
16
40
880
870
430
360
150
408
390
256
236
52
3
95
141
183
1093
11.5
130
21
72
23
50
1065 1055
430
360
150
408
390
256
236
52
3
95
141
183
1278
11.5
130
21
72
27
60
1250 1240
430
360
150
408
390
256
236
52
3
95
141
183
1463
11.5
130
21
72
30
70
1065 1055
530
365
157
506
492
289
233
41
3
88
145
172
1278
12.2
130
26
68
34
80
1250 1240
530
365
157
500
489
245
234
40
0
83
143
186
1463
12.2
125
30
65
41
Dimensions are in millimeters ; weight in kilograms.
23
To provide optimal fan-coil unit selection, we supplies computer selection capability. The SELECT'IT selection program will select
the most economical unit size to meet the specification.
To operate the SELECT'IT software, the user needs a microcomputer using Windows : XP, Vista or Seven.
Ref. : EDM AQF-A.11GB/03.13 - Supersedes : EDM AQF-A.10GB/02.13
Contact your nearest representative for a copy of SELECT'IT software or for a unit selection that meets the most exacting
specifications.
www.airwell.com
AIRWELL France SAS
1bis, Avenue du 8 mai 1945 - Saint Quentin en Yvelines
78284 GUYANCOURT - France
Tel. +33 (0)1 39 44 78 00
Fax +33 (0)1 39 44 65 17
As part of our ongoing product improvement programme, the technical data and colours of our products are subject to change without prior notice. Non contractual photos.
Computer fan-coil selection by SELEC'IT software

Similar documents

Carisma CRC-ECM

Carisma CRC-ECM refer to Carisma CRC Fan Coil Unit, except for Electronic motor: three phase permanent magnet brushless electronic motor that is controlled with current reconstructed according to a BLAC sinusoidal...

More information

Water Source Heat Pumps - Vertical Mounting Version Models 07 to

Water Source Heat Pumps - Vertical Mounting Version Models 07 to High temperature safety function : the "ICT & LWT" temperature sensors check that the condensation temperature at the finned coil and the water temperature at the outlet of the water/refrigerant he...

More information