Aqu@Fan II
Engineering Data Manual eration New : New gen Aqu@Fan II Fan Coil Units Models AWC, AWN, AHC, AHN EC1 motor Quality, efficiency and reliability, built into every unit... Vertical console units with cabinet, AWC type Support feet supplied as optional AWC vertical console units are designed for use in three different types of installation : - as a wall hung console in areas where a skirting board prevents the use of a floor mounted console ; - as a floor console with optional front air intake RF (most frequently located below a large window) ; - as a floor console with support feet and bottom air intake. They feature a modern decorative style cabinet with matching plastic discharge grille, providing a high performance unit that is attractive and durable which will complement any room decor. The AWC models can be fitted, as optional, with electromechanical or electronic Aqu@Net control, with valve kits, etc. Vertical concealed units without cabinet, AWN type AWN vertical chassis only units are designed for applications that require a fully concealed or a fully recessed installation. These units include all the features of the AWC vertical console unit type except that only the chassis is supplied instead of decorative style cabinet. Like the AWC units, Aqu@Net control (except the remote control) as well as other electromechanical controls and valve kits can be fitted, as optional, on unit. Units can be fitted with optional feet (supplied loose), if floor mounting is required. Ceiling exposed units with cabinet, AHC type AHC ceiling exposed units are designed for ceiling mounting in areas where it is necessary to conserve floor space. They contain all the features of the AWC unit within the decorative style cabinet with matching plastic discharge grille. Standard version is designed for rear horizontal air intake without inlet grille. Similar to the previous models, the Aqu@Net control can be supplied, as optional, on AHC units with remote control. Other optional controls and valve kits are also available. Bottom air intake grille supplied as optional Ceiling concealed units without cabinet, AHN type AHN ceiling chassis units are designed for concealed or recessed ceiling installations. This unit consists of the AHC basic unit horizontally installed. AHN units contain all the features of the AHC ceiling exposed units except that only the chassis casing is supplied instead of the decorative style cabinet. Possibility of supplying separately an optional Aqu@Net type remote control for wall mounting. Other optional controls and valve kits are also available. Auxiliary drain pan supplied as optional 2 New range of fan coil units Aqu@Fan II : "Innovation for an optimum comfort" Easy to install, improvement in sound levels and performances, Aqu@Net electronic control, etc., are the key developments carried on our fan coil units. Moreover, the new technology of the fan motor assembly, through the use of optimized centrifugal impellers, associated with a 5-speed motor enables all Aqu@Fan II models to reach an average decrease in sound levels of - 4dBA, compared with the previous range, offering therefore a maximum acoustical comfort. The Aqu@Fan II fan coil unit range is issued from that development striving to meet customers’ wishes and advices. Aesthetic of the grille, associated with the casing refined finish allows a harmonious and smart integration of the fan coil units Aqu@Fan II in all types of interiors. Aqu@Fan II range is provided with an electronic control : Aqu@Net, whose ergonomic and discrete remote command can be loose or fitted on the fan coil unit. They are the ideal solution to air condition agreeably and efficiently, flats, hotels, hospitals, offices and other premises, all year long. All settings being made at factory, no needs to be done by installer. The Aqu@Fan II fan coil units range includes 7 sizes with air flows ranging from 140 thru 1400 m3/h, for cooling capacities of 2 thru 9 kW. This control, especially innovating, offers as standard a master/slave function up to 15 units from one single remote control. The Aqu@Fan II fan coil units are equipped with optimized coils to bring the best possible performances in 2-pipe, 4-pipe, or 2-pipe/2-wire versions. Other features like window contact, occupied/unoccupied, antifreeze modes are integrated without involving any price add. Design features For the 2-pipe/2-wire systems, the electric heating coil is composed of heating rod type resistances mounted inside the coil (at the place of hot water tubes). Cabinet All units are manufactured from heavy-gauge zinc coated sheet steel for long life and durability. Oven baked powder epoxy paint insures a good protection and an attractive finish for all outside panels (Standard colour : RAL 9003). Note : The water connection side is defined left-hand or right-hand when observer is looking at the unit from the discharge side. The standard discharge grille is made of "ABS" plastic and has a different colour from the cabinet (standard colour : Pantone 427C). Fan and motor assembly On the versions with optional front intake, monobloc grille, painted in RAL 9003, is mounted flush to the cabinet. Grille can be removed by releasing the two quarter turn fixing screws to get access to the filter. The units are fitted with a fan-motor assembly of which the fan is composed of double inlet forward curved centrifugal wheel(s) dynamically balanced and specially designed for an optimal air flow and a low noise level. Casing The Aqu@Fan II range can be supplied with 2 types of motor : -The standard AC motor of asynchrone direct drive type having 5 speeds, 3 of them are factory pre-wired, equipped with a built-in normally closed thermal protection of automatic reset type. Made of galvanized steel insulated with closed cell polyethylene foam. Casing has 4 slotted lugs on its rear side which allow the unit to be easily and quickly installed at site, in wall or ceiling mounting. -The EC1 motor of high efficiency and low electrical consumption type for a significant energy saving. The motor is suitable for 0-10 V input, ensuring variable speed capability. It is fitted with ECospeed3 interface card (supplied as standard) for a 3-speed optimized running. Available on sizes 20-30-40-50-60. Access to all internal components of the unit is facilitated by an easy dismounting of the casing. Condensate drain pan is fabricated from galvanized sheet steel coated with closed cell polyethylene foam on external face. The drain pan is painted to insure the anticorrosion protection. Power supply : 230 V±10%/1 Ph/50 Hz - 60 Hz (50 Hz on size 70). All models are equipped with an inclined condensate drain pan to ensure optimal condensate draining and to minimize water retention. Electrical connections Units are supplied complete with internal electrical wiring terminating in a junction block protected by a cap or the cabinet. Moreover, models 20 to 70 are also equipped with a V-shape pan in order to allow either vertical or horizontal installation. Cabinet internal space allows installation of optional control systems supplied by manufacturer or others. Coils When the optional Aqu@Net control is fitted on the unit, the controller includes a junction block for power supply connection and incorporates, as standard, a cable clamp. Made of staggered copper tubes, mechanically expanded into high efficiency hydrophilic aluminium fins, assuring maximum heat transfer efficiency. Each fan coil unit is equipped with a 3-row cooling coil plus 1 row optional heating coil. Filter On model 80, the 4-pipe and 2-pipe/2-wire coils are supplied in one finned block. On models 20 to 70, the 4-pipe and 2-pipe/2-wire coils are additionnal to the 2-pipe coil. Easily removable cleanable filter having fire class M1 and G2 efficiency. Filter media is mounted on a metallic frame. Options Each coil is supplied with headers having air vent at the highest point and drain plug at the lowest point. The water connection of each header is 1/2" gas female threaded type. Many different options and accessories are available for all units : see chapter "Mounting accessories". Controls are shown in the corresponding chapter. Models designation Aqu@Fan II fan coil unit A W N 40. 30 E 1500 W : vertical wall unit H : horizontal ceiling unit E : electric heating coil with capacity in Watts Hot water coil : 0 without coil - 1 with 1 row C : model with cabinet N : model without cabinet Chilled water coil : 3 with 3 rows Sizes : 20, 30, 40, 50, 60, 70, 80 3 Energy performance of Aqu@Fan II with new generation EC1 motor Energy class More efficient Size 20 Models 2030 2031 FCEER FCCOP Size 30 Models 3030 3031 FCEER FCCOP Less efficient Size 40 Models 4030 4031 FCEER FCCOP Size 50 Models 5030 5031 FCEER FCCOP Size 60 Models 6030 6031 FCEER FCCOP Energy savings Electrical consumption with EC1 motor (in Watts) Models Size 20 Size 30 Size 40 Size 50 Size 60 V1 14 28 23 32 47 V2 13 18 14 17 36 V3 7 13 10 14 23 V4 6 10 8 8 19 V5 4 7 6 7 13 Without control consumption, static pressure 0 Pa. 3-speed control interface for EC1 motor Aqu@Net Interface card 3 speeds EC1 motor 0 to 10 V ECoSpeed3 4 EC1, EC and AC motor absorbed power comparison Aqu@Fan II size 20 50 45 AC motor 40 Pabs (W) 35 30 EC motor 25 20 15 10 EC1 motor 5 0 0 50 100 150 200 250 300 350 Qv (m /h) 3 Aqu@Fan II size 30 70 60 AC motor 50 Pabs (W) 40 EC motor 30 20 10 EC1 motor 0 0 100 200 300 400 500 Qv (m3/h) Aqu@Fan II size 40 60 AC motor 50 Pabs (W) 40 EC motor 30 20 10 EC1 motor 0 0 100 200 300 Qv (m3/h) 5 400 500 600 EC1, EC and AC motor absorbed power comparison (continued) Aqu@Fan II size 50 70 AC motor 60 Pabs (W) 50 40 EC motor 30 20 EC1 motor 10 0 0 200 400 600 800 Qv (m3/h) Aqu@Fan II size 60 120 100 AC motor Pabs (W) 80 60 EC motor 40 20 EC1 motor 0 0 200 400 600 800 1000 Qv (m3/h) Operating range with EC1 motor : Voltage setpoint Models Minimum starting voltage (V) Minimum voltage with electric heater (V) Maximum optimized voltage (V) 20 1.5 1.7 5.5 30 1.5 3.1 8.2 40 1.5 2.4 6.6 50 1.5 2.8 7.6 60 1.5 4.4 9.0 6 Aqu@Fan II AWC Models - Mounting Accessories Options and accessories STD standard version for wall mounting (no support feet supplied). MP support feet for floor mounting. MPG air intake grille between feet. RF front air intake grille (no support feet supplied). RP back partial air intake with support feet. RT back full air intake with support feet. RC floor air intake with support feet. RVCA-RT air intake arrangement with motorized (non controlled) on/off damper (back or front intake). RVCA-RC air intake arrangement with motorized (non controlled) on/off damper (floor or front intake). RVCM-RT air intake arrangement with manual damper (back or/and front intake). RVCM-RC air intake arrangement with manual damper (floor or/and front intake). TMT telescopic wall sleeve. TMTG telescopic wall sleeve with external grille (filter not supplied). RH cabinet backwrap for plinth. ALV finished back panel (for unit mounted in front of glass wall). BAC auxiliary drain pan (for units without motorized valves). FLOOR FIX floor fixing brackets (for MP and ALV). STD MP/MPG RC TMTG RVCA-RC * RVCM-RT * RF RP * RT RVCA-RT * RVCM-RC * * Can be fitted with optional intake grille between feet. 7 RH * ALV * Aqu@Fan II AWN Models - Mounting Accessories Options and accessories STD standard version for wall mounting (no support feet supplied). MP support feet for floor mounting. RD front air intake. RP back partial air intake with support feet. RT back full air intake with support feet. RC floor air intake with support feet. RVCA-RT air intake arrangement with motorized (non controlled) on/off damper (back or front intake). RVCA-RC air intake arrangement with motorized (non controlled) on/off damper (floor or front intake). RVCM-RT air intake arrangement with manual damper (back or/and front intake). RVCM-RC air intake arrangement with manual damper (floor or/and front intake). TMT telescopic wall sleeve. TMTG telescopic wall sleeve with external grille (filter not supplied). BAC auxiliary drain pan (for units without motorized valves). CRG discharge duct collar. STD MP RP RT RVCA-RC RVCM-RC RC RVCA-RT RVCM-RT TMTG 8 RD CRG Aqu@Fan II AHC Models - Mounting Accessories Options and accessories STD standard ceiling mounted version with rear air intake (no inlet grille). RF bottom air intake grille. RVCA-RC air intake arrangement with motorized (non controlled) on/off damper. RVCM-RC air intake arrangement with manual damper. RC rear air intake with support feet. MP support feet. MPG air intake grille between feet. THI return air perforated panel with filter media. TMT telescopic wall sleeve. TMTG telescopic wall sleeve with external grille (filter not supplied). BAC auxiliary painted drain pan (for units without motorized valves). std thi rvca-rc/rvcm-rc rf mp/mpg rc tmtg Aqu@Fan II AHN Models - Mounting Accessories Options and accessories STD standard ceiling mounted version with rear air intake (no inlet grille). RVCA-RC air intake arrangement with motorized (non controlled) on/off damper. RVCM-RC air intake arrangement with manual damper. RD bottom air intake. RC rear air intake with support feet. CRG discharge duct collar. TMT telescopic wall sleeve. TMTG telescopic wall sleeve with external grille (filter not supplied). BAC auxiliary painted drain pan (for units without motorized valves). std CRG RC TMTG 9 RD RVCA-RC/RVCM-RC Aqu@Fan II - Available Options Coils AWC AWN AHC AHN XX30 3 row main coil - 2 pipe system Yes Yes Yes Yes XX31 3 row main coil + 1-row additional coil - 4 pipe system Yes Yes Yes Yes XX30E 3 row main coil + standard electric heating coil - 2 pipe / 2 wire system Yes Yes Yes Yes Note : XX = size of unit (for example : 2030 = fan coil size 20 with 3-row main coil - 2 pipe system). 2-way control valve - 2-pipe system - 230 Volt thermal actuator 1 valve, 2-way type - For 2-pipe system on cooling or heating coil W2G1 Valve Thermal attenuator 230 V - 50/60 Hz Sizes KV Ø T max amb T max fluid Id (A) In (A) P (VA) 20/60 1.6 1/2" 50 °C 110 °C 0.6 0.013 3.0 70/80 2.5 3/4" 50 °C 110 °C 0.6 0.013 3.0 2-way control valve - 4-pipe system - 230 Volt thermal actuator W2G2 2 valves. 2-way type - For 4-pipe system on cooling and heating coils Cooling valve Heating valve Thermal actuator(s) 230 V - 50/60 Hz Sizes KV Ø KV Ø T max amb T max fluid Id (A) In (A) P (VA) 20/60 1.6 1/2" 1.6 1/2" 50 °C 110 °C 0.6 0.013 3.0 70/80 2.5 3/4" 1.6 1/2" 50 °C 110 °C 0.6 0.013 3.0 4-way control valve - 2-pipe system - 230 Volt thermal actuator 1 valve. 4-way type - For 2-pipe system on cooling or heating coil W4G1 Valve Thermal actuator 230 V - 50/60 Hz Sizes KV Ø T max amb T max fluid Id (A) In (A) P (VA) 20/60 1.6 1/2" 50 °C 110 °C 0.6 0.013 3.0 70/80 2.5 3/4" 50 °C 110 °C 0.6 0.013 3.0 4-way control valve - 4-pipe system - 230 Volt thermal actuator W4G2 2 valves. 4-way type - For 4-pipe system on cooling and heating coils Cooling valve Heating valve Thermal actuator(s) 230 V - 50/60 Hz Sizes KV Ø KV Ø T max amb T max fluid Id (A) In (A) P (VA) 20/60 1.6 1/2" 1.6 1/2" 50 °C 110 °C 0.6 0.013 3.0 70/80 2.5 3/4" 1.6 1/2" 50 °C 110 °C 0.6 0.013 3.0 10 Aqu@Fan II - Main Controls (Optional) CMV (supplied fitted) Manual fan speed selector TBV (supplied fitted) Electromechanical control with valve 2 ✔ AWC 1 3 AWC ✔ AWN ✔ AHC ✔ AHN ✘ 4 AWN ✔ AHC ✔ AHN ✘ 5 P1 P3 4 3 1 2 5 1 Heat LS MS P1 P3 P1 M N (Blue) LS MS HS Extra speeds Cool HS N (Blue) Extra speeds 0 V M 1 2 3 N Ph 1 2 3 G N Ph 230V/1Ph/50Hz G 230V/1Ph/50Hz Action on valve and fan, 2-pipe system in heating or cooling mode. Set of thermostat + 4-position manual speed selector : OFF/LS/MS/HS. Option TBV1 for action on valve only with constant fan operation. For reversible 2-pipe system with summer/winter automatic changeover, possibility of mounting with a water changeover sensor PCO, use of 4-way valve is mandatory. 4 position manual fan speed selector : OFF/LS/MS/HS. TBMV (supplied fitted) Electromechanical control with valve(s) 2 1 3 AWC ✔ AWN ✔ AHC ✔ AHN ✘ 4 2 5 1 4 LS MS HS N (Blue) Extra speeds 5 2 P1 SD 1 3 M Cool 6 Heat P3 P1 HV CV 1 2 N Ph G 230V/1Ph/50Hz Action on valves and fan, 4-pipe, 2-pipe/2-wire or manual changeover 2-pipe system. Set of thermostat + summer/winter switch + 4-position manual speed selector: OFF/LS/MS/HS. Option TBMV1 for action on valve(s) only with constant fan operation. For 4-pipe or manual changeover 2-pipe system, possibility of mounting a low temperature cut-out sensor SD (temp. range 45 °C/35 °C) on hot water piping to stop fan operation. 11 Aqu@Fan II - Main Controls (Optional) (continued) CMVM (supplied loose) Manual fan speed selector TRM-FA (supplied loose) Electromechanical remote control Extra speeds AWC ✔ AWN ✔ M HS MS LS Ground M ✔ Neutral/Blue 1 2 3 4 5 6 M 1 Power supply 220-240/1/50 2 3 HV LS AHN CV MS ✔ HS AHC Yellow/Green Yellow/Green Neutral/Blue Extra speeds 4 5 6 7 8 M GROUND NEUTRAL GROUND 1N230V~ PHASE L L AWC ✔ AWN ✔ AHC ✔ AHN ✔ NEUTRAL PHASE N 0/I L TRM CMVM Wall mounted remote thermostat to control valves and fan. Suitable for 4-pipe (with cooling and heating valves), 2-pipe/2-wire (with cooling valve and electric heater), 2-pipe (with cooling or heating valve) and reversible 2-pipe (with manual changeover) systems. Control buttons : ON/OFF; Summer/Winter changeover; Manual fan speed selector : LS/MS/HS. 4 position manual fan speed selector : OFF/LS/MS/HS. TRM-VP (supplied loose) Electromechanical remote control TAE20 (supplied loose) Electronic remote thermostat M AWC ✔ AWN ✔ AHC ✔ AHN ✔ Extra speeds CV 20 HV 4 Neutral/Blue 1 2 3 5 3 30 4 5 6 7 8 M AWC ✔ AWN ✔ AHC ✔ AHN ✔ L N 3 2 1 3 2 1 1 2 3 4 5 6 7 8 NEUTRAL 9 10 M PHASE N CF 5 LS MS 4 GROUND 1N230V~ 25 10 HS Yellow/Green 15 SEH CV HV L TRM Ph N G 230V/1Ph/50Hz Adjustable dead zone electronic thermostat with summer/winter automatic changeover. Wall mounted remote thermostat to regulate control valve(s). Suitable for 4-pipe (with cooling and heating valves), 2-pipe/2-wire (with cooling valve and Suitable for 4-pipe (with cooling and heating valves), 2-pipe/2-wire (with cooling valve and electric heater (TAE 20BE)), 2-pipe (with cooling or heating valve) or reversible 2-pipe (with or electric heater), 2-pipe (with cooling or heating valve) and reversible 2-pipe (with manual without extra electric heating, 4-way valve mandatory and SEH changeover sensor) system. changeover) systems. Controls buttons : ON/OFF, manual fan speed selector : LS/MS/HS, NO (normally open) or NC Control buttons : ON/OFF; Summer/Winter changeover; Manual fan speed selector : LS/MS/HS. (normally closed) window contact CF. 12 Aqu@Fan II - Main Controls (Optional) (continued) Aqu@Net communicating electronic control FCC electronic controller (supplied fitted) RCL wire remote control with digital display (supplied loose or fitted) POWER SUPPLYY 230V/1Ph/50Hz R2 CV RED LS Pump VL1 ✔ AHC ✔ AHN ✔ J1 F/M BLACK HS AWN VL2 F/L VIOLET MS SR F/H UNOC NIU M N VL1 N VL2 N BROWN ✔ GROUND to the casing EH2 N BLUE AWC L F/N EH2 EH1 EH1 N NEUTRAL BLUE LT Pump N R1 HV YELLOW/GREEN RED WIN RED ALARM RAT 4 3 2 BLACK BLACK WPT WPT 1 Controller can be configured in 2-pipe heating only or cooling only, 2-pipe/2-wire, reversible Wire remote control for wall mounting or for mounting on AWC units. 2-pipe with or without extra electric heating or 4-pipe system. Keyboard with locking device and buttons : ON/Standby; fan operation (auto or manual); operation mode (cooling, heating, auto or fan operation only); temperature setpoint Other pre-programmed functionalities included : master/slaves up to 15 units controlled from adjustment in different modes. one remote control only; NC window contact; automatic or manual selection of unoccupied Functioning LED. mode; antifreeze mode. Aqu@Net communicating electronic control System networking µBMS programmable supervision station (supplied loose) °C Wed AUTO UNIT TEMP MODE NIGHT PROG SET HOUR SWING LOCAL UNIT + DAY CLEAR µBMS Minisupervision station TEMP Bus RS485 MODE NIGHT PROG SET HOUR SWING LOCAL UNIT up to 100 units + CLEAR DAY FCC controller NIU board up to 100 units RCL wire remote control In association with FCC controllers through a communication bus and interface board (NIU), µBMS allows 15 different zones with 100 units to be managed. RS485 communication bus system allowing user to monitor 100 fan coil units through a Other functionalities included either in global or individual control by zone : supervision station (µBMS), with FCC Aqu@Net controllers fitted with interface boards (NIU) - Daily and weekly programming of running times (2 hour ranges), and with local controls (RCL). - Programming and setting of temperature setpoints (cooling, heating, auto), Max. length of bus = 1000 meters, shielded twisted pair cable. - Choice of operation mode (cooling, heating, auto or fan operation only), - Choice of fan operation speed (auto or manual). 13 Aqu@Fan II - Technical Data Air flow - 3-row dry coil Speeds V1 V2 V3 V4 V5 2030 317 282 223 178 132 3030 407 350 290 253 181 4030 570 470 385 352 295 5030 736 554 471 359 333 6030 917 770 650 593 468 7030 1150 1070 799 656 545 8030 1376 1069 934 793 665 Electrical data 230 V/1 Ph/50 Hz (standard motor) Unit sizes V1 Max. running absorbed power (W) Max. absorbed current (A) 20 30 40 50 60 70 80 45 60 57 66 107 150 188 V2 37 49 47 50 81 130 132 V3 27 40 39 45 64 110 112 V4 19 33 36 40 55 101 101 V5 16 24 33 39 41 92 90 0,17 0,28 0,27 0,31 0,5 0,7 0,95 Note : Data compatible with 60 Hz, except size 70. Water volume (liters) Sizes 20 30 40 50 60 70 80 Water volume (liters) 1-row (Heating) 0.24 0.34 0.43 0.52 0.61 0.69 0.92 3-row (Cooling) 0.62 0.90 1.18 1.46 1.73 2.19 2.60 Operating limits Environmental conditions Water circuit Minimum premise air temperature / new air intake / around the apparatus Maximale premise air temperature / new air intake / around the apparatus Max. operating pressure Min. entering water temperature Max. entering water temperature 14 5 °C / 15% RH 32 °C / 70% RH 17 bars +5 °C +90 °C Aqu@Fan II - Optional Electric Heating Coil Data Electric heaters with heating rods supplied fitted BE1 BE2 20 300 600 30 300 600 40 500 1000 50 600 1200 60 750 1500 70 750 1500 80 900 1800 BE3 BE4 900 (1) (300+600) 900 (1) (300+600) 1500 (1) (500+1000) 1800 (1) (600+1200) 2250 (1) (750+1500) 2250 (1) (750+1500) 2700 (1) (900+1800) 1200 (1) (600+600) 2000 (1) (1000+1000) 2400 (1) (1200+1200) 3000 (1) (1500+1500) 3000 (1) (1500+1500) 3600 (1) (1800+1800) BE3 BE4 NA (1) Available in 2 steps suitable for Aqu@Net control. NA : Not available. Electric heaters with heating rods supplied loose BE1 BE2 20 300 600 30 300 600 40 500 1000 50 600 1200 60 750 1500 70 750 1500 900 (1) (300+600) 900 (1) (300+600) 1500 (1) (500+1000) 1800 (1) (600+1200) 2250 (1) (750+1500) 2250 (1) (750+1500) (1) Available in 2 steps suitable for Aqu@Net control. NA : Not available. 15 NA 1200 (1) (600+600) 2000 (1) (1000+1000) 2400 (1) (1200+1200) 3000 (1) (1500+1500) 3000 (1) (1500+1500) Performance Data Aqu@Fan II - 2-pipe System 3-row main coil Sizes 2030 3030 4030 5030 6030 7030 8030 Cooling Heating Speeds Humid air flow (m3/h) Pt (W) Ps (W) WPD (kPa) Pc (W) WPD (kPa) V1 V2 V3 V4 V5 V1 V2 V3 V4 V5 V1 V2 V3 V4 V5 V1 V2 V3 V4 V5 V1 V2 V3 V4 V5 V1 V2 V3 V4 V5 V1 V2 V3 V4 V5 292 259 205 164 121 374 322 267 233 167 524 432 354 324 271 677 510 433 330 306 844 708 598 546 431 1058 984 735 604 501 1266 983 859 730 612 1.87 1.75 1.47 1.26 1.04 2.44 2.28 2.13 1.92 1.52 3.46 3.08 2.62 2.47 2.19 4.22 3.17 2.8 2.24 2.10 5.73 4.94 4.39 4.08 3.40 7.21 6.84 5.61 4.81 3.92 9.04 7.59 6.65 5.68 4.75 1.48 1.35 1.11 0.93 0.75 1.94 1.73 1.56 1.39 1.02 2.73 2.35 1.97 1.83 1.60 2.98 2.20 1.92 1.52 1.42 3.85 3.27 2.86 2.64 2.22 5.64 5.17 4.17 3.56 2.89 6.89 5.62 4.92 4.19 3.51 8.00 7.00 5.00 4.00 3.00 16.0 15.0 12.0 10.0 7.00 33.0 26.0 20.0 18.0 14.0 29.0 17.0 14.0 9.00 8.00 42.0 32.0 26.0 23.0 16.0 25.0 22.0 16.0 12.0 8.00 39.0 29.0 23.0 17.0 12.0 2.53 2.39 2.02 1.65 1.24 3.40 3.02 2.61 2.29 1.74 4.57 4.18 3.50 3.23 2.69 5.41 4.26 3.71 3.05 2.83 7.36 6.18 5.25 4.85 3.99 9.18 8.41 6.90 6.01 4.94 11.3 9.27 8.36 7.11 5.99 8.00 7.00 5.00 4.00 3.00 13.0 12.0 11.0 9.00 6.00 28.0 22.0 17.0 15.0 12.0 24.0 15.0 12.0 8.00 7.00 35.0 27.0 22.0 19.0 14.0 21.0 19.0 13.0 12.0 7.00 33.0 24.0 19.0 14.0 10.0 Performances based on : Summer : air 27 °C/19 °C (wet bulb) and chilled water 7/12 °C. Winter : air 20 °C, entering water température 50 °C, water flow identical to cooling mode. Pt : Total cooling capacity. Ps : Sensible cooling capacity. Pc : Heating capacity. WPD : Water pressure drop. Standard wiring of the 3 speeds. Other speed combinations available upon request. 16 Performance Data Aqu@Fan II - 4-pipe System 3-row cooling main coil + 1-row heating complementary coil Sizes 2031 3031 4031 5031 6031 7031 8031 Cooling Heating Speeds Humid air flow (m3/h) Pt (W) Ps (W) WPD (kPa) Pc (W) WPD (kPa) V1 V2 V3 V4 V5 V1 V2 V3 V4 V5 V1 V2 V3 V4 V5 V1 V2 V3 V4 V5 V1 V2 V3 V4 V5 V1 V2 V3 V4 V5 V1 V2 V3 V4 V5 282 251 199 158 118 362 312 259 225 161 508 419 343 314 263 656 493 420 320 297 817 685 579 528 417 1024 953 712 584 486 1226 952 832 707 592 1.97 1.85 1.54 1.33 1.08 2.39 2.20 2.08 1.87 1.48 3.40 3.01 2.56 2.41 2.13 4.22 3.68 3.25 2.59 2.43 5.61 4.84 4.29 3.98 3.31 7.12 6.68 5.47 4.69 3.81 8.83 7.40 6.49 5.54 4.63 1.52 1.39 1.14 0.95 0.76 1.88 1.65 1.52 1.35 0.99 2.66 2.29 1.92 1.78 1.55 3.00 2.71 2.37 1.88 1.74 3.77 3.20 2.80 2.58 2.17 5.54 5.04 4.06 3.46 2.81 6.71 5.46 4.78 4.08 3.41 42.0 37.0 27.0 20.0 14.0 15.0 14.0 12.0 10.0 7.00 31.0 25.0 19.0 17.0 14.0 20.5 16.0 13.0 9.00 8.00 40.0 31.0 25.0 22.0 16.0 24.0 21.0 15.0 11.0 8.00 38.0 28.0 22.0 16.0 12.0 2.32 2.23 1.98 1.71 1.39 3.34 3.10 2.80 2.58 2.16 4.54 4.23 3.73 3.52 3.21 5.25 4.51 4.01 3.43 3.23 6.06 5.55 5.11 4.86 4.18 6.98 6.26 5.27 4.96 4.28 11.6 10.3 9.43 8.14 6.75 6.00 5.00 4.00 3.00 2.00 13.0 11.0 9.00 8.00 6.00 25.0 22.0 17.0 16.0 13.0 50.0 38.0 32.0 23.0 21.0 15.0 13.0 11.0 10.0 8.00 24.0 19.0 15.0 12.0 9.00 48.0 38.0 33.0 25.0 18.0 Performances based on : Summer : air 27 °C/19 °C (wet bulb) and chilled water 7/12 °C. Winter : air 20 °C, hot water 70/60 °C. Pt : Total cooling capacity. Ps : Sensible cooling capacity. Pc : Heating capacity. WPD : Water pressure drop. Standard wiring of the 3 speeds. Other speed combinations available upon request. 17 Aqu@Fan II - Sound Data AWC/AHC Sizes 2030 3030 4030 5030 6030 7030 8030 Speeds Lw global (dBA) Lp* global (dBA) V1 V2 V3 V4 V5 V1 V2 V3 V4 V5 V1 V2 V3 V4 V5 V1 V2 V3 V4 V5 V1 V2 V3 V4 V5 V1 V2 V3 V4 V5 V1 V2 V3 V4 V5 53 49 43 36 34 56 52 48 45 37 52 47 42 40 37 55 48 45 39 37 61 56 52 49 43 65 61 54 50 46 66 59 56 53 49 45 41 35 28 26 48 44 40 37 29 44 39 34 32 29 47 40 37 31 29 53 48 44 41 35 57 53 46 43 38 58 51 48 45 41 AWN NR* Lw global (dBA) Lp* global (dBA) 41 37 31 24 22 44 40 36 33 24 39 35 29 27 24 43 37 33 27 23 48 44 39 36 31 52 48 41 38 34 54 48 44 41 36 53 49 45 38 34 56 52 48 45 37 52 47 42 40 37 55 48 45 39 37 61 56 52 49 43 65 61 56 50 48 66 59 56 53 49 43 39 35 28 24 46 42 38 35 27 42 37 32 30 27 45 38 35 29 27 51 46 42 39 33 55 51 46 40 38 56 49 46 43 39 AHN NR* Lw global (dBA) Lp** global (dBA) NR** 39 35 30 23 19 42 38 34 31 22 37 33 27 25 22 41 35 31 25 23 46 42 37 34 29 50 46 41 35 34 52 46 42 39 34 53 49 45 38 34 56 52 48 45 37 52 47 42 40 37 55 48 45 39 37 61 56 52 49 43 65 61 56 50 48 66 59 56 53 49 32 28 24 17 <15 35 31 27 24 16 31 26 21 19 16 34 27 24 18 16 40 35 31 28 22 44 40 35 29 27 45 38 35 32 28 28 24 19 <15 <15 31 27 23 20 <15 26 22 16 <15 <15 30 24 20 <15 <15 35 31 26 23 18 39 35 30 24 23 41 35 31 28 23 (*) The sound pressure levels Lp are based on (NR) characteristic of a room having volume of 100 m 3 with reverberation time of 0.5 seconds and at a distance of 1 meter. (**) Informative data, considering a sound attenuation of the room and installation of 21 dB. 18 Aqu@Fan II - Sound Data (continued) AWC/AHC Sizes 2031 3031 4031 5031 6031 7031 8031 Speeds Lw global (dBA) Lp* global (dBA) V1 V2 V3 V4 V5 V1 V2 V3 V4 V5 V1 V2 V3 V4 V5 V1 V2 V3 V4 V5 V1 V2 V3 V4 V5 V1 V2 V3 V4 V5 V1 V2 V3 V4 V5 53 50 44 37 35 56 52 49 45 41 52 47 42 40 37 55 48 45 39 37 62 58 55 51 47 65 61 56 51 47 66 59 57 54 49 45 42 36 29 27 48 44 41 37 33 44 39 34 32 29 47 40 37 31 29 54 50 47 43 39 57 53 48 43 39 58 51 49 46 41 AWN NR* Lw global (dBA) Lp* global (dBA) 41 37 32 25 23 44 40 37 33 28 39 35 30 27 24 43 37 33 27 24 49 45 42 38 34 52 48 43 38 35 54 48 45 42 36 53 50 44 37 35 56 52 49 45 39 52 47 42 40 37 55 48 45 39 37 62 58 55 51 47 65 61 56 51 47 66 59 57 54 49 43 40 34 27 25 46 42 39 35 29 42 37 32 30 27 45 38 35 29 27 52 48 45 41 37 55 51 46 41 37 56 49 47 44 39 AHN NR* Lw global (dBA) Lp** global (dBA) NR** 39 36 29 22 20 42 38 35 31 24 37 33 27 25 22 41 35 31 25 23 47 44 40 36 33 50 46 41 36 33 52 46 43 40 34 53 50 44 37 35 56 52 49 45 41 52 47 42 40 37 55 48 45 39 37 62 58 55 51 47 65 61 56 51 47 66 59 57 54 49 32 29 23 16 <15 35 31 28 24 20 31 26 21 19 16 34 27 24 18 16 41 37 34 30 26 44 40 35 30 26 45 38 36 33 28 28 24 19 <15 <15 31 27 24 20 <15 26 22 17 <15 <15 30 24 20 <15 <15 36 32 29 25 21 39 35 30 25 22 41 35 32 29 23 (*) The sound pressure levels Lp are based on (NR) characteristic of a room having volume of 100 m3 with reverberation time of 0.5 seconds and at a distance of 1 meter. (**) Informative data, considering a sound attenuation of the room and installation of 21 dB. 19 Dimensional Data - Aqu@Fan II AWC Models horizontal discharge grille A 231 204 73 170 90 B 100 Auxiliary condensate drain pan and support feet supplied as optional wall mounting rightleft 220 C Discharge 2 TOP 1 M8 fixing screws 4 x 8 mm D 4 4 3 2 3 1 H G I J BOTTOM I J F Return L K G H E 100 220 L K M N M N 100 Ground level Ground level 1 2 3 4 100 Ground level : auxiliary coil water inlet : auxiliary coil water outlet : main coil water inlet : main coil water outlet Models A B C D E F G H I J K L M N Weight 20 768 478 500 430 360 150 408 390 256 236 52 95 141 183 20 30 953 478 685 430 360 150 408 390 256 236 52 95 141 183 23 40 1138 478 870 430 360 150 408 390 256 236 52 95 141 183 30 50 1323 478 1055 430 360 150 408 390 256 236 52 95 141 183 35 60 1508 478 1240 430 360 150 408 390 256 236 52 95 141 183 39 70 1323 578 1055 530 365 157 506 492 289 233 41 88 145 172 42 80 1508 578 1240 530 365 157 500 489 245 234 40 83 143 186 50 Dimensions are in millimeters ; weight in kilograms. 20 Dimensional Data - Aqu@Fan II AWN Models front view - left hand connections wall mounting C A 70 15 15 Discharge TOP Auxiliary condensate drain pan (Option) M8 fixing screws 4 x 8 mm Electrical side protection cap 105 B D E F BOTTOM 40 100 Ground level Return 100 top view - left hand connections Ground level rightleft Auxiliary condensate drain pan (Option) Electrical side protection cap 220 K’ 220 2 105 1 70 A G 16 mm OD condensate outlet 4 3 H I K’ 220 L K Auxiliary condensate drain pan L K 4 2 1 3 H J J top view - discharge duct connections G I 108 108 M N 100 M N Ground level 100 Q O 15 P 15 1 2 3 4 A : auxiliary coil water inlet : auxiliary coil water outlet : main coil water inlet : main coil water outlet Models A B C D E F G H I J K K' L M N O P Q Weight 20 510 430 500 430 360 150 408 390 256 236 52 3 95 141 183 130 - 11.5 14 30 695 430 685 430 360 150 408 390 256 236 52 3 95 141 183 130 - 11.5 16 40 880 430 870 430 360 150 408 390 256 236 52 3 95 141 183 130 - 11.5 23 50 1065 430 1055 430 360 150 408 390 256 236 52 3 95 141 183 130 - 11.5 27 60 1250 430 1240 430 360 150 408 390 256 236 52 3 95 141 183 130 - 11.5 30 70 1065 530 1055 530 365 157 506 492 289 233 41 3 88 145 172 130 - 12.2 34 80 1250 530 1240 530 365 157 500 489 245 234 40 0 83 143 186 136 20 12.2 41 Dimensions are in millimeters ; weight in kilograms. 21 Dimensional Data - Aqu@Fan II AHC Models bottom view ceiling mounting Discharge C A Auxiliary condensate pan (optional) Discharge M8 fixing screws Main condensate pan 16 mm OD condensate outlet D B E F Return 90 170 Return left hand water connections side view Auxiliary condensate pan (optional) 16 mm OD condensate outlet Auxiliary condensate pan (optional) 16 mm OD condensate outlet 4 1 220 2 3 2 3 231 K L 204 4 N M K’ 1 B J I Models 20 30 40 50 60 70 80 A 768 953 1138 1323 1508 1323 1508 : auxiliary coil water inlet : auxiliary coil water outlet : main coil water inlet : main coil water outlet B 478 478 478 478 478 578 578 C 500 685 870 1055 1240 1055 1240 D 430 430 430 430 430 530 530 204 1 2 3 4 E 360 360 360 360 360 365 365 F 150 150 150 150 150 157 157 G 408 408 408 408 408 506 500 H 390 390 390 390 390 492 489 Dimensions are in millimeters ; weight in kilograms. 22 I 256 256 256 256 256 289 245 J 236 236 236 236 236 233 234 K 52 52 52 52 52 41 40 K' 3 3 3 3 3 3 0 L 95 95 95 95 95 88 83 M 141 141 141 141 141 145 143 N 183 183 183 183 183 172 186 231 discharge view H G Weight 20 23 30 35 39 42 50 Dimensional Data - Aqu@Fan II AHN Models bottom view - left hand water connections 145 C 70 A Auxiliary condensate pan (optional) ceiling mounting Discharge Main condensate pan M8 fixing screws D D E F 16 mm OD condensate outlet Electrical side protection side Return discharge view left hand water connections A 15 15 Auxiliary condensate pan (optional) Auxiliary condensate pan (optional) 16 mm OD condensate outlet Electrical side protection cap 220 Main condensate pan 4 145 N M 70 O 220 2 3 K’ K L 1 discharge duct connections J I H G S P Q R 15 15 A 1 2 3 4 70 Caution ! Do not fix duct to edge of condensate drain pan, in order to allow pan removal. Models A C D E F G H I J K K' L : auxiliary coil water inlet : auxiliary coil water outlet : main coil water inlet : main coil water outlet M N O P Q R S Weight 20 510 500 430 360 150 408 390 256 236 52 3 95 141 183 723 11.5 130 21 72 14 30 695 685 430 360 150 408 390 256 236 52 3 95 141 183 908 11.5 130 21 72 16 40 880 870 430 360 150 408 390 256 236 52 3 95 141 183 1093 11.5 130 21 72 23 50 1065 1055 430 360 150 408 390 256 236 52 3 95 141 183 1278 11.5 130 21 72 27 60 1250 1240 430 360 150 408 390 256 236 52 3 95 141 183 1463 11.5 130 21 72 30 70 1065 1055 530 365 157 506 492 289 233 41 3 88 145 172 1278 12.2 130 26 68 34 80 1250 1240 530 365 157 500 489 245 234 40 0 83 143 186 1463 12.2 125 30 65 41 Dimensions are in millimeters ; weight in kilograms. 23 To provide optimal fan-coil unit selection, we supplies computer selection capability. The SELECT'IT selection program will select the most economical unit size to meet the specification. To operate the SELECT'IT software, the user needs a microcomputer using Windows : XP, Vista or Seven. Ref. : EDM AQF-A.11GB/03.13 - Supersedes : EDM AQF-A.10GB/02.13 Contact your nearest representative for a copy of SELECT'IT software or for a unit selection that meets the most exacting specifications. www.airwell.com AIRWELL France SAS 1bis, Avenue du 8 mai 1945 - Saint Quentin en Yvelines 78284 GUYANCOURT - France Tel. +33 (0)1 39 44 78 00 Fax +33 (0)1 39 44 65 17 As part of our ongoing product improvement programme, the technical data and colours of our products are subject to change without prior notice. Non contractual photos. Computer fan-coil selection by SELEC'IT software
Similar documents
Carisma CRC-ECM
refer to Carisma CRC Fan Coil Unit, except for Electronic motor: three phase permanent magnet brushless electronic motor that is controlled with current reconstructed according to a BLAC sinusoidal...
More informationWater Source Heat Pumps - Vertical Mounting Version Models 07 to
High temperature safety function : the "ICT & LWT" temperature sensors check that the condensation temperature at the finned coil and the water temperature at the outlet of the water/refrigerant he...
More information