Water Source Heat Pumps - Vertical Mounting Version Models 07 to
Transcription
Water Source Heat Pumps - Vertical Mounting Version Models 07 to
Refrigerant R407C CW-AR Water Source Heat Pumps - Vertical Mounting Version Models 07 to 12 2.4 to 3.1kW 1.9 to 2.7kW Some advantages... RAL 9010 painted cabinet 3-fan speeds G2 filter is supplied as standard. Front or bottom access to the filter. Temperature range : 13 to 45 °C EC version is available as optional Front panel is very easy to remove in order to facilitate access to internal components. Direct external access Schrader valves (HP&LP) available for a pressure tap on the refrigerant circuit. STORM 2 electronic board and RCL remote control are delivered as standard 1 RCL x 10 units 2 Unit Description Generalities Water connections RAL 9010 painted cabinet with optimal compactness. High efficiency units with high COP values. The water source outlet and return connectors are located on the outside of the unit in several configurable positions. They are of female gas threaded type (1/2"). Complete access to the compressor, fan and electrical box, through front removable panel. The condensate drain connection is of smooth tube type with an outside diameter of 16 mm. Condensate drain pan with anti-corrosion treatment by oven-baked epoxy paint.. Water feeding sides : BACK / RIGHT / LEFT / MIDDLE. Fan motor equipped with 3 ventilation speed, or optional EC version. A flow switch of SIKA type will be factory supplied as standard in order to avoid any compressor damage. Heat exchanger with brazed stainless steel plates on the water/ refrigerant side, for improved efficiency. Electrical box Stand-alone control by a STORM 2 electronic board which can be configured using the RCL user remote control, which comprises a digtal display and essential control keys. Holes are provided in the casing for entry of electrical power supply and remote control cables. Optional TAC branded XENTIA type LON control associated to TH STR 106. The electrical power supply for CW-AR units is 230V/1Ph/50Hz. Compressor is standard equipped with an internal thermal protection with an automatic reset function. Introduction Refrigerant circuit The new generation of CW-AR water source heat pumps is the fruit of our considerable product experience and our awareness of the market, all combined with a technology based on the energy efficiency of machines, in order to provide on the market units with the highest performance in terms of COP. The refrigerant circuit comprises a rotary type hermetic compressor, a cycle reversal valve, a water/refrigerant heat exchanger, a liquid receiver, and a finned coil. The refrigerant circuit also comprises an HP pressure switch with automatic reset function (range 29-24 bar) and an LP pressure switch with an automatic reset function (range 1.4-2.4 bar). Two direct external access Schrader valves (HP & LP) are available for pressure tapping on the refrigerant circuit. Operating range To enable a much wider operating range and installation using a water source in an application with a dry cooler, the standard CW-AR units are designed to operate in a water source temperature range between 13 and 45 °C. The water/refrigerant heat exchanger is of the brazed stainless steel plate type, for increased efficiency. The anti-freeze safety of the heat exchanger is provided by a water pipe sensor located on the water outlet of the unit monitored by the electronic board. Maximum service pressure water side (27.5 bar) and refrigerant side (30 bar). The heat exchangers are particularly well adapted to the operation of reversible heat pumps with high thermal transfer rates for a low water flow rate. Cabinet The cabinet is made of galvanised sheet steel painted RAL 9010. To facilitate access to the main components, front removable panel provides access to the compressor, the fan and the electrical box. The air/refrigerant coil is made of aluminium fins which are mechanically crimped onto copper tubes. The geometry of the coil and of the fin profile have been carefully designed to provide maximum efficiency in the operation of the units. The condensate drain pan has anti-corrosion treatment consisting of ovenbaked epoxy paint. The inside of the cabinet, on the fan compartment side, is coated with 15 mm thick closed cell polyurethane foam thermal-acoustic insulation, classified M1. The cycle reversal valve is designed to be normally energised in heating mode. This logic enables the heat pump to continue to operate in cooling mode if this valve fails. On the compressor compartment side, the thermal-acoustic insulation is of 20 mm thick Isofeutre type with heavy mass. The liquid receiver enables the charge of HFC 407C refrigerant to be optimised, in order to maintain a high COP value. Versions Ventilation section The CW-AR range is available in several versions : The fan compartment contains the fan-motor assembly, the air/refrigerant coil and the condensate drain pan. The ventilation section is completely isolated from compressor compartment by a thermally and acoustically insulated partition wall. CW-AR CAR : standard version with cabinet, CW-AR CARB : low height version with cabinet, CW-AR NU : standard version without cabinet, Wide removable panels provide access to the various internal components. The condensate drain pan has an anti-corrosion treatment. CW-AR NUB : low height version without cabinet. Each version can be supplied, as standard, with feet or with front air intake RF (optional). All the units are equipped with a 3 speed direct-drive fan motor with ipsothermal protection against overheating during operation. The motor ipsothermal protection fault is displayed in the form of a coded signal on the LED of the RCL remote control. Filtration All units are equipped as standard with a disposable G2 filter. The 3 fan speeds can be controlled either manually or automatically by the electronic management board of the unit. Access to the filter can be realized by the front or the bottom (according to the version CW-AR RF or CW-AR with feet). EC optional motor available on request. 3 Versions CW-AR CAR with feet CW-AR CAR with front air intake RF CW-AR CARB with feet CW-AR CARB with front air intake RF CW-AR NU with feet CW-AR NU with front air intake RF CW-AR NUB with feet CW-AR NUB with front air intake RF 4 Control Features STORM 2 electronic board RCL user remote control All CW-AR water source heat pumps are, in their standard version, equipped with a STORM 2 electronic board which manages their operation and their safety devices. STORM 2 electronic board Master/slaves control : the standard version of the STORM 2 electronic board enables operation in master/slaves regulation mode for up to 10 water source heat pumps using a single RCL user remote control. This configuration enables the installer to save on the purchase and wiring of equipment such as auxiliary relays and multi-wire cables between the various water source heat pumps. Only a bus cable with 2 twisted pairs is necessary between the master and slave units. RCL user remote control When a request for operation in cooling mode is received, the fan-motor assembly is started up immediately and the compressor does not start until after an effective time delay of 180 seconds. The RCL remote control enables operation in cooling-only mode or in automatic cooling/heating mode with, at a given temperature set-point used as a switch-over point, a neutral switch-over range of +/-3 °C from cooling to heating mode. In cooling mode, the fan runs permanently and the 3 speed ventilation can be implemented in automatic or manual mode : HS, MS, or LS. An RCL user remote control is supplied as standard in the electrical control box of the units. It enables individually controlled operation as stand-alone regulation. The RCL remote control is ergonomically designed and discreet. It comprises a digital display and essential functions such as : On/Off, When a request for operation in heating mode is received, the fan-motor startup is controlled by the electronic board and the temperature of the ICT sensor; the reversal valve is activated before the compressor and the latter does not start until after an effective time delay of 180 seconds. The RCL remote control enables operation in heating-only mode or in automatic heating/ cooling mode with, at a given temperature set-point used as a switch-over point, a neutral switch-over range of +/-3 °C from heating to cooling mode. In heating mode, the fan can operate either cyclically (the fan stops when the set temperature is reached) or permanently and the 3 speed ventilation can be implemented in automatic or manual mode: HS, MS, or LS. Selection of operating mode, Room temperature display, Fan speed selection, Temperature set-point adjustment. A keypad locking function is also available. The RCL user remote control comprises a Display LED which shows the operating status of the water source heat pump (Lit : On - Unlit : Off), and it also enables an operational fault to be identified by flashing a specific code. Measurement of the room air temperature : the STORM 2 card electronic regulation enables the selection of a room temperature measurement mode which uses an ambient temperature sensor (RCT) in the RCL remote control, or a return temperature sensor (RAT) located directly on the water source heat pump. Anti-short cycle : after each compressor shut-down, a time delay of 180 seconds is introduced by the electronic board. This time delay constitutes an anti-short cycle device and therefore helps to protect the compressor. 5 Control Features (continued) Variable sequential start-up function : when the system is first energised, or after a power cut, or after opening the "CLK" contact, a random time delay of 0 to 30 seconds is introduced by the electronic board to prevent the water source heat pumps from all starting up simultaneously, thus avoiding a power surge. µBMS mini-supervision station Emergency shut-down / stand-by / night setback : the electronic board has two "CLK" terminals which shut the unit down immediately. 32 water source heat pumps in 15 zones from a single point, in addition to This centralised control unit is proposed as an option, and can be connected to the STORM 2 electronic board as a supervision station to monitor and manage the local RCL remote controls. By incorporating a zone thermostat in series, the "CLK" contact can also be used as a night setback and the water source heat pump will start up again as soon as the ambient temperature drops below the set point of the setback thermostat. The µBMS mini-supervision station enables the zones to be programmed with global control for all zones, or with individual control of each zone Anti-freeze safety function : this is provided by two temperature sensors. In cooling mode an "ICT" temperature sensor located in the finned coil protects the water source heat pump against accidental freezing. with programming of the operating time ranges over a 7 day period, with In heating mode, the safety function is provided by an "LWT" minimum water outlet temperature sensor. The anti-freeze fault read by the temperature sensor is displayed by a coded signal on the LED of the RCL remote control. It also provides the possibility of having different set-points in different zones. management of the heating, cooling and night setback modes. µBMS mini-supervision station High temperature safety function : the "ICT & LWT" temperature sensors check that the condensation temperature at the finned coil and the water temperature at the outlet of the water/refrigerant heat exchanger do not exceed the authorised limits. The manual reset HP pressure switch completes the high temperature safety function. The high temperature safety fault read by the ICT and LWT sensors and the HP pressure switch cut-off is displayed by a coded signal on the LED of the RCL remote control. Fault reports : the electronic regulation carried out by the STORM 2 board uses coded signals to remotely report four different possible machine faults on the display LED of the RCL remote control : - HP pressure switch triggering, - Water temperature fault in low limit, - Water temperature fault in high limit, - Anti-freeze protection. The STORM 2 electronic board also enables the general machine fault to be sent to a remote fault relay via a dry contact. Motorized valve : The STORM 2 electronic board has a 230 volt output for an (optional) motorized valve controlled by the operation of the compressor, in order to enable the flow-rate of the hydraulic pump(s) to be regulated according to the manometric pressure in the water source. 6 Operating Limits Environment This equipment is designed for an internal installation only. In general, the sheltered locations, such as garages, attic, etc, do not provide sufficient protection against extreme temperatures and/or humidity, and the performance, the reliability and the life span of the equipment can be decreased. Temperature limits Cooling Return air temperature Entering water temperature Heating Minimum 21 °C dry bulb / 15 °C wet bulb 15 °C Nominal * 27 °C dry bulb / 19 °C wet bulb 20 °C Maximum 32 °C dry bulb / 23 °C wet bulb 27 °C Minimum 23 °C 12 °C Nominal * 30 °C 20 °C Maximum 42 °C 34 °C ** Temperature and water flow limits are independant of fan speed. * Nominal conditions according to EN 14511-2. ** 32 °C for model CW-AR 07 at LS (low speed). Flow limits CW-AR 07 Water flow (l/h) 650 600 550 500 450 400 350 300 250 200 150 100 50 0 20 22 24 26 28 30 32 34 36 Entering water temperature (°C) 38 40 42 44 650 600 550 Low Speed 500 Water flow (l/h) 450 400 350 Medium Speed and High Speed 300 250 200 150 100 50 0 10 12 14 16 18 20 22 24 26 Entering water temperature (°C) 7 28 30 32 34 36 Operating Limits (continued) Flow limits Water flow (l/h) CW-AR 09 650 600 550 500 450 400 350 300 250 200 150 100 50 0 20 22 24 26 28 30 32 34 36 38 40 42 44 Entering water temperature (°C) 650 600 Water flow (l/h) 550 500 450 400 350 300 250 200 150 100 50 0 10 12 14 16 18 20 22 24 26 28 30 32 34 36 Entering water temperature (°C) Water flow (l/h) CW-AR 12 650 600 550 500 450 400 350 300 250 200 150 100 50 0 20 22 24 26 28 30 32 34 36 38 40 42 44 Entering water temperature (°C) 650 600 550 Water flow (l/h) 500 450 400 350 300 250 200 150 100 50 0 10 12 14 16 18 20 22 24 26 28 Entering water temperature (°C) 8 30 32 34 36 Physical Data Models CAPACITIES Total cooling capacities (1) Sensible cooling capacities (1) Heating capacities (2) VENTILATION Air flow (Low Speed) Air flow (Medium Speed) Air flow (High Speed) Motor power Fan speeds Air filter - Number / Efficiency Air filter (front) - Dimensions / Thickness Air filter (bottom) - Dimensions / Thickness HYDRAULIC CIRCUIT Water heat exchanger Maximum water pressure Nominal water flow (1) Cutoff water flow versus nominal water flow WPD at nominal water flow Hydraulic connections - Inlet / Outlet Condensate outlet Ø REFRIGERANT CIRCUIT Number of circuit Compressor WEIGHT WITHOUT CABINET / WITH CABINET Operating weight SOUND DATA Sound power Lw (Low Speed) Sound power Lw (Medium Speed) Sound power Lw (High Speed) ELECTRICAL DATA Power input - Cooling mode (3) Power input - Heating mode (3) Electrical power supply Fan max. current Compressor nominal current (4) Compressor starting current (5) CWAR 07 CWAR 09 CWAR 12 W W W 1942 1526 2431 2136 1775 2542 2743 2340 3156 m3/h m3/h m3/h W Nbr 250 340 400 75 3 340 400 460 75 3 1 / G2 660 x 205 mm / 6 mm 595 x 187 mm / 6 mm 400 460 510 75 3 mm mm Nbr bar l/s % kPa Inches mm 0.119 44 5 0.171 31 12 1 Rotary Type kg 1 3 0.133 40 3,4 ISO G 1/2'' INT 15 x 20 55 / 70 58 / 73 60 /75 dB(A) dB(A) dB(A) 49 50 51 50 51 53 51 53 54 W W 598 710 892 954 A A A 0.2 2.8 16 647 720 230V/1Ph/50Hz ±10% 0.25 3 16 0.3 4 18.9 (1) Nominal cooling capacities based on : entering air temperature of 27 °C dry bulb, 19 °C wet bulb with entering water temperature of 30 °C. (2) Nominal heating capacities based on : entering air temperature of 20 °C dry bulb, 15 °C wet bulb with entering water temperature of 20 °C. (3) Absorbed power (compressor + fan) at nominal conditions. (4) Nominal currents are given at +/- 5%. (5) Starting currents are given at +/- 10%. Dimensions (in mm) - All Sizes Versions Length Width Height with feet Height with front air intake With cabinet CAR 1138 251 821 720÷750 With cabinet CARB 1323 251 683 580÷610 9 Without cabinet NU 1086 229 769 667÷697 Without cabinet NUB 1184.5 229 624 525÷555 Cooling Performance Data - CW-AR 07 Nominal airflow 340 m3/h - Medium Speed Entering Water Temp. (°C) 20 27 30 32 38 40 Water Water flow Pressure Drop (l/s) (kPa) 0.119 5.0 0.089 2.8 0.060 1.3 0.119 5.0 0.089 2.8 0.060 1.3 0.119 5.0 0.089 2.8 0.060 1.3 0.119 5.0 0.089 2.8 0.060 1.3 0.119 5.0 0.089 2.8 0.060 1.3 0.119 5.0 0.089 2.8 0.060 1.3 Cooling mode TEA (°C) TSE (°C) Pt (W) Ps (W) Pabs (W) CR (W) EER 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24.9 25.1 25.3 26.5 26.8 27.1 29.8 30.2 30.7 31.8 32.1 32.2 27.8 33.7 34.0 36.7 37.1 37.6 34.8 35.0 35.3 36.4 36.7 37.0 39.5 40.0 40.5 36.8 37.0 37.1 38.3 38.6 38.9 41.4 41.8 42.3 42.7 42.9 43.2 44.3 44.6 44.9 47.3 47.8 48.1 44.7 44.8 45.1 46.2 46.4 46.8 49.2 49.7 50.1 1967 2071 2170 1942 2052 2151 1935 2016 2138 1864 1992 2072 1850 1959 2054 1840 1929 2065 1829 1942 2047 1820 1928 2031 1779 1892 2012 1802 1922 1972 1776 1863 1963 1732 1835 1941 1711 1810 1915 1704 1803 1907 1650 1755 1837 1669 1748 1875 1645 1734 1852 1613 1719 1815 1538 1602 1663 1526 1595 1666 1520 1558 1652 1485 1565 1616 1474 1548 1563 1458 1533 1620 1465 1526 1608 1454 1514 1604 1441 1516 1596 1451 1530 1568 1438 1501 1520 1412 1493 1539 1404 1477 1491 1404 1477 1555 1371 1454 1493 1387 1455 1525 1366 1436 1519 1356 1430 1493 485 486 492 491 495 497 511 516 521 541 542 543 546 550 551 574 581 583 568 570 571 575 578 579 592 596 602 587 591 592 594 599 602 611 618 622 648 650 653 657 660 663 668 674 682 660 664 667 669 672 674 686 691 697 2452 2557 2662 2433 2547 2649 2446 2532 2659 2405 2534 2615 2396 2509 2605 2414 2510 2649 2397 2512 2618 2395 2506 2610 2371 2488 2614 2389 2513 2564 2370 2462 2565 2343 2453 2563 2359 2460 2568 2361 2463 2570 2318 2429 2519 2329 2412 2542 2314 2405 2526 2299 2410 2512 4.06 4.26 4.41 3.95 4.14 4.32 3.79 3.91 4.10 3.45 3.68 3.82 3.39 3.56 3.73 3.20 3.32 3.54 3.22 3.41 3.58 3.16 3.33 3.51 3.01 3.17 3.34 3.07 3.25 3.33 2.99 3.11 3.26 2.83 2.97 3.12 2.64 2.79 2.93 2.59 2.73 2.88 2.47 2.61 2.69 2.53 2.63 2.81 2.46 2.58 2.75 2.35 2.49 2.60 TEA : Entering air temperature (dry bulb/wet bulb). TSE : Leaving water temperature. Pt : Total cooling capacity. Ps : Sensible cooling capacity. Pabs : Compressor power input. CR : Total heat rejection. 10 Heating Performance Data - CW-AR 07 Nominal airflow 340 m3/h - Medium Speed Entering Water Temp. (°C) Water Water flow Pressure Drop (l/s) (kPa) 0.119 5.0 0.089 2.8 0.119 5.0 0.089 2.8 0.060 1.3 0.119 5.0 0.089 2.8 0.060 1.3 0.119 5.0 0.089 2.8 0.060 1.3 0.119 5.0 0.089 2.8 0.060 1.3 0.119 5.0 0.089 2.8 0.060 1.3 13 16 20 27 30 32 Heating mode TEA (°C) Pc (W) Pabs (W) CA (W) COP 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 2204 2055 2246 1994 1977 1952 2251 2280 2329 2158 2166 2110 2046 2035 2012 2457 2431 2395 2386 2363 2326 2264 2238 2055 2896 2864 2811 2805 2778 2727 2638 2609 2582 3090 3054 2992 3000 2959 2904 2819 2785 2738 2974 2937 2875 2868 2842 2789 2703 2685 2622 611 660 752 575 613 689 614 664 766 599 675 722 583 625 702 636 682 769 628 672 758 612 656 739 665 719 820 661 714 811 652 700 795 671 727 832 671 723 827 661 713 813 606 659 758 607 659 753 605 653 745 1593 1394 1494 1419 1364 1264 1637 1616 1563 1558 1491 1387 1463 1410 1310 1821 1749 1626 1758 1691 1568 1652 1582 1315 2231 2145 1991 2143 2064 1916 1986 1909 1788 2420 2327 2159 2330 2236 2078 2157 2072 1925 2368 2279 2117 2262 2183 2036 2099 2031 1877 3.61 3.11 2.99 3.47 3.22 2.83 3.66 3.44 3.04 3.60 3.21 2.92 3.51 3.26 2.87 3.86 3.56 3.11 3.80 3.52 3.07 3.70 3.41 2.78 4.36 3.98 3.43 4.24 3.89 3.36 4.05 3.73 3.25 4.61 4.20 3.59 4.47 4.09 3.51 4.26 3.91 3.37 4.91 4.46 3.79 4.73 4.31 3.70 4.47 4.11 3.52 TEA : Entering air temperature. Pc: Heating capacity. Pabs : Compressor power input. CA : Total heat absorption. 11 Cooling Performance Data - CW-AR 09 Nominal airflow 400 m3/h - Medium Speed Entering Water Temp. (°C) 20 27 30 32 38 40 Water Water flow Pressure Drop (l/s) (kPa) 0.133 3.4 0.100 1.2 0.067 0.5 0.133 3.4 0.100 1.2 0.067 0.5 0.133 3.4 0.100 1.2 0.067 0.5 0.133 3.4 0.100 1.2 0.067 0.5 0.133 3.4 0.100 1.2 0.067 0.5 0.133 3.4 0.100 1.2 0.067 0.5 Cooling mode TEA (°C) TSE (°C) Pt (W) Ps (W) Pabs (W) CR (W) EER 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24.8 25.0 25.2 26.4 26.7 26.9 29.6 29.9 30.4 31.7 32.0 32.1 27.8 33.6 33.8 36.5 36.8 37.4 34.7 35.0 35.1 36.3 36.6 36.8 39.3 39.8 40.3 36.7 36.9 37.0 38.2 38.4 38.7 41.2 41.6 42.0 42.6 42.8 43.0 44.2 44.4 44.7 47.1 47.5 47.9 44.6 44.7 45.0 46.0 46.3 46.6 49.0 49.4 49.8 2164 2278 2387 2136 2257 2366 2128 2217 2352 2050 2191 2279 2035 2155 2259 2024 2122 2271 2012 2136 2252 2002 2121 2234 1957 2081 2213 1982 2114 2169 1953 2049 2159 1905 2018 2135 1882 1991 2106 1874 1983 2097 1815 1930 2020 1836 1923 2062 1809 1907 2037 1774 1891 1996 1789 1864 1934 1775 1855 1938 1768 1812 1922 1727 1821 1880 1715 1801 1818 1696 1784 1885 1704 1775 1870 1691 1761 1866 1676 1764 1856 1688 1780 1824 1673 1745 1768 1642 1737 1790 1633 1718 1734 1633 1718 1808 1595 1691 1737 1614 1692 1774 1589 1670 1766 1577 1663 1737 517 518 524 523 528 530 544 550 555 576 577 578 582 586 587 611 619 621 605 607 608 613 616 617 630 635 641 625 629 630 632 638 641 651 658 662 690 692 695 700 703 706 712 717 726 703 707 711 713 715 717 731 736 743 2680 2796 2911 2659 2785 2896 2672 2767 2907 2626 2768 2857 2616 2741 2846 2635 2741 2893 2616 2743 2860 2614 2736 2851 2587 2716 2854 2607 2743 2799 2586 2687 2800 2556 2676 2797 2572 2683 2802 2574 2686 2804 2527 2648 2747 2539 2630 2773 2522 2622 2754 2505 2627 2739 4.19 4.40 4.55 4.08 4.28 4.47 3.91 4.03 4.24 3.56 3.80 3.94 3.50 3.68 3.85 3.31 3.43 3.66 3.33 3.52 3.70 3.27 3.44 3.62 3.10 3.28 3.45 3.17 3.36 3.44 3.09 3.21 3.37 2.93 3.07 3.22 2.73 2.88 3.03 2.68 2.82 2.97 2.55 2.69 2.78 2.61 2.72 2.90 2.54 2.67 2.84 2.43 2.57 2.69 TEA : Entering air temperature (dry bulb/wet bulb). TSE : Leaving water temperature. Pt : Total cooling capacity. Ps : Sensible cooling capacity. Pabs : Compressor power input. CR : Total heat rejection. 12 Heating Performance Data - CW-AR 09 Nominal airflow 400 m3/h - Medium Speed Entering Water Temp. (°C) Water Water flow Pressure Drop (l/s) (kPa) 0.133 3.4 0.100 1.2 0.133 3.4 0.100 1.2 0.067 0.5 0.133 3.4 0.100 1.2 0.067 0.5 0.133 3.4 0.100 1.2 0.067 0.5 0.133 3.4 0.100 1.2 0.067 0.5 0.133 3.4 0.100 1.2 0.067 0.5 13 16 20 27 30 32 Heating mode TEA (°C) Pc (W) Pabs (W) CA (W) COP 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 2305 2148 2348 2085 2067 2042 2354 2384 2435 2256 2265 2206 2139 2127 2104 2569 2542 2505 2495 2471 2432 2368 2340 2148 3028 2995 2939 2933 2904 2852 2758 2728 2700 3231 3193 3128 3137 3094 3037 2947 2912 2863 3370 3329 3259 3251 3220 3161 3063 3042 2971 609 658 750 574 611 687 612 662 764 598 673 720 582 623 699 634 680 767 626 670 756 610 654 737 663 717 817 659 712 808 650 698 792 669 725 830 669 721 824 659 711 811 667 726 836 669 726 830 666 720 821 1696 1490 1599 1512 1456 1355 1741 1722 1672 1659 1592 1486 1558 1505 1404 1935 1862 1738 1869 1801 1677 1757 1687 1411 2365 2278 2122 2273 2192 2043 2108 2030 1908 2563 2468 2298 2469 2373 2213 2288 2201 2053 2703 2603 2423 2582 2495 2331 2397 2322 2150 3.78 3.26 3.13 3.64 3.38 2.97 3.84 3.60 3.19 3.78 3.37 3.06 3.68 3.42 3.01 4.05 3.74 3.27 3.99 3.69 3.22 3.88 3.58 2.91 4.57 4.18 3.60 4.45 4.08 3.53 4.24 3.91 3.41 4.83 4.41 3.77 4.69 4.29 3.68 4.47 4.10 3.53 5.05 4.59 3.90 4.86 4.44 3.81 4.60 4.23 3.62 TEA : Entering air temperature. Pc: Heating capacity. Pabs : Compressor power input. CA : Total heat absorption. 13 Cooling Performance Data - CW-AR 12 Nominal airflow 460 m3/h - Medium Speed Entering Water Temp. (°C) 20 27 30 32 38 40 Water Water flow Pressure Drop (l/s) (kPa) 0.171 12.0 0.128 6.8 0.086 3.0 0.171 12.0 0.128 6.8 0.086 3.0 0.171 12.0 0.128 6.8 0.086 3.0 0.171 12.0 0.128 6.8 0.086 3.0 0.171 12.0 0.128 6.8 0.086 3.0 0.171 12.0 0.128 6.8 0.086 3.0 Cooling mode TEA (°C) TSE (°C) Pt (W) Ps (W) Pabs (W) CR (W) EER 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24/17 27/19 30/21 24.9 25.1 25.3 26.5 26.8 27.0 29.7 30.1 30.6 31.8 32.1 32.2 28.1 33.7 33.9 36.6 37.0 37.6 34.8 35.0 35.2 36.4 36.7 36.9 39.5 39.9 40.4 36.8 37.0 37.1 38.3 38.6 38.8 41.4 41.8 42.2 42.7 42.9 43.1 44.3 44.6 44.8 47.3 47.7 48.1 44.7 44.8 45.1 46.2 46.4 46.7 49.2 49.6 50.0 2778 2925 3065 2743 2898 3038 2733 2848 3020 2633 2814 2927 2613 2767 2901 2599 2725 2917 2583 2743 2891 2571 2723 2869 2513 2672 2842 2545 2715 2785 2508 2631 2773 2446 2592 2742 2417 2556 2705 2407 2547 2694 2330 2479 2595 2357 2469 2648 2323 2449 2616 2278 2428 2564 2358 2457 2549 2340 2446 2554 2330 2389 2533 2277 2400 2478 2260 2374 2397 2236 2351 2485 2246 2340 2465 2230 2322 2460 2210 2325 2447 2225 2346 2405 2205 2301 2330 2165 2290 2359 2153 2265 2286 2153 2265 2384 2103 2230 2290 2127 2231 2338 2095 2202 2329 2079 2192 2290 717 719 728 727 733 736 756 763 771 800 802 803 808 814 815 849 860 863 840 843 845 851 855 857 875 881 891 868 874 875 878 886 891 904 914 920 958 961 966 972 976 981 989 996 1009 976 982 987 990 993 996 1015 1022 1032 3496 3644 3793 3470 3631 3774 3489 3611 3791 3433 3615 3730 3421 3581 3717 3448 3584 3780 3423 3586 3736 3421 3578 3726 3388 3554 3732 3413 3588 3661 3387 3517 3663 3351 3505 3661 3375 3517 3670 3378 3523 3674 3319 3475 3603 3334 3451 3635 3313 3442 3612 3293 3450 3595 3.87 4.07 4.21 3.78 3.96 4.13 3.62 3.73 3.92 3.29 3.51 3.64 3.23 3.40 3.56 3.06 3.17 3.38 3.08 3.25 3.42 3.02 3.18 3.35 2.87 3.03 3.19 2.93 3.11 3.18 2.86 2.97 3.11 2.71 2.84 2.98 2.52 2.66 2.80 2.48 2.61 2.75 2.36 2.49 2.57 2.41 2.51 2.68 2.35 2.47 2.63 2.25 2.37 2.49 TEA : Entering air temperature (dry bulb/wet bulb). TSE : Leaving water temperature. Pt : Total cooling capacity. Ps : Sensible cooling capacity. Pabs : Compressor power input. CR : Total heat rejection. 14 Heating Performance Data - CW-AR 12 Nominal airflow 460 m3/h - Medium Speed Entering Water Temp. (°C) Water Water flow Pressure Drop (l/s) (kPa) 0.171 12.0 0.128 6.8 0.171 12.0 0.128 6.8 0.086 3.0 0.171 12.0 0.128 6.8 0.086 3.0 0.171 12.0 0.128 6.8 0.086 3.0 0.171 12.0 0.128 6.8 0.086 3.0 0.171 12.0 0.128 6.8 0.086 3.0 13 16 20 27 30 32 Heating mode TEA (°C) Pc (W) Pabs (W) CA (W) COP 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 16 20 27 2861 2667 2916 2589 2567 2535 2922 2960 3023 2801 2813 2739 2656 2641 2612 3190 3156 3110 3098 3068 3020 2939 2905 2667 3759 3718 3649 3641 3606 3540 3425 3387 3352 4012 3964 3884 3895 3842 3770 3659 3615 3555 4184 4133 4046 4036 3998 3925 3803 3777 3689 811 876 998 763 814 914 815 881 1016 795 896 958 774 829 931 844 905 1021 833 891 1006 812 870 981 882 954 1088 878 948 1076 865 929 1054 890 964 1105 890 960 1097 878 946 1079 888 966 1112 890 966 1105 887 958 1092 2051 1791 1918 1826 1753 1621 2107 2079 2007 2006 1917 1781 1882 1813 1681 2346 2251 2089 2265 2176 2014 2127 2036 1686 2877 2765 2561 2764 2658 2465 2559 2458 2298 3122 3000 2779 3005 2882 2673 2782 2669 2476 3296 3167 2934 3146 3032 2820 2917 2819 2596 3.53 3.04 2.92 3.39 3.15 2.77 3.59 3.36 2.98 3.52 3.14 2.86 3.43 3.19 2.81 3.78 3.49 3.05 3.72 3.44 3.00 3.62 3.34 2.72 4.26 3.90 3.35 4.15 3.81 3.29 3.96 3.64 3.18 4.51 4.11 3.52 4.38 4.00 3.44 4.17 3.82 3.30 4.71 4.28 3.64 4.54 4.14 3.55 4.29 3.94 3.38 TEA : Entering air temperature. Pc: Heating capacity. Pabs : Compressor power input. CA : Total heat absorption. 15 Dimensions - CW-AR CAR with Feet 251 105 716 1138 16 Dimensions - CW-AR CAR with Front Air Intake 251 716 720 mini 750 maxi 1138 17 Dimensions - CW-AR CARB Low Height with Feet 251 105 683 578 1323 18 Dimensions - CW-AR CARB Low Height with Front Air Intake 251 580 mini 610 maxi 1323 19 Dimensions - CW-AR NU with Feet 40.5 1005 40.50 24 92 105 624 769 522 142.5 229 54 530 20 Dimensions - CW-AR NU with Front Air Intake 502 525 mini 555 maxi 142.50 229 1005 24 92 38.50 54 530 21 Dimensions - CW-AR NUB Low Height with Feet 229 1005 139 105 624 522 40.5 18 100 1183 54 530 22 Dimensions - CW-AR NUB Low Height with Front Air Intake 229 38.50 1144 100 18 138.50 502 525 mini 555 maxi 1005 54 530 23 Systemair Airwell SAS · route de Verneuil, 27570 Tillières-sur- Avre · Tél. 02 32 60 61 00 · Fax 02 32 32 55 13 september 2014 Systemair · EDM CWAR-S-1GB/09.14 As part of our ongoing product improvement programme, our products are subject to change without prior notice. Non contractual photos. www.systemair.fr
Similar documents
Aqu@Fan II
cabinet, AWN type AWN vertical chassis only units are designed for applications that require a fully concealed or a fully recessed installation. These units include all the features of the AWC vert...
More informationtechnical annual 2002
FOR RETURNING FAULTY MODULES ALLEGARE AL PEZZO CHE VIENE RIMANDATO INDIETRO POUR RETOURRNER AVEC LE MODULE DEFECTUEUX PARA DEVOLUCIÓN DE MÓDULOS AVERIADOS
More information