a0.0 328 4th ave s, kirkland, wa 98033 east unit
Transcription
a0.0 328 4th ave s, kirkland, wa 98033 east unit
328 4TH AVE S, KIRKLAND, WA 98033 EAST UNIT MUST REMAIN ON Install amended soils per City of Kirkland pre-approved plan CK-E.12 112' - 0" " 111' - 0" 110' - 0 N 89'47'36"E 109' - 0" 108' - 0" 0" 107' - 0" 106' - 105' - 0" 104' - 0" 0" TREE #204 TREE # 1 30' - 0" 5' - 0" TREE # 2 TREE # 3 C - 105.7' REAR PATIO 63 SF REAR PATIO 63 SF TREE #106 LOT 8 LOT 9 F.F.E. 100.12' F.F.E. 104.29' F.F.E. 107.27 5' - 0" TREE #105 5' - 0" A - 107.7' 2.0 FRONT ENTRY 87 SF TREE # 5 CONCRETE WALKWAY 82 SF 14.9 % DRIVEWAY 394 SF FRONT SETBACK TREE # 4 20' - 0" 11.5 % 21' - 8 3/4" 13.5 % 20' - 0" FRONT SETBACK DRIVEWAY 394 SF CONCRETE WALKWAY 82 SF DRIVEWAY 394 SF TREE #201 TREE #104 TREE # 6 2.0 % WATER METER TYP. PER CIVIL DRAWINGS 2.0 % PROPERTY LOT LINE BOTTOM EL=96.0 2.0 % 5' - 0" 2.0 % BOTTOM EL=93.0 1236 SF 87 SF 63 SF 14 SF 394 SF 82 SF 0 SF 1876 SF 58.62 % 112' - 0" 111' 0" " 4TH AVENUE SOUTH PCD Approved Site Plan: Any proposed changes to the approved site plan, such as but not limited to added hard surfaces, HVAC units, tree removals, and accessory structures, must be submitted to the Building Department as a revision to the building permit for review and approval by all departments prior to implementation. RELOCATE EX. WATER METER AS REQUIRED PER CIVIL DRAWINGS All mechanical units shall comply with the maximum environmental noise levels established pursuant to the Noise Control Act of 1974, Revised Code of Washington (RCW) 70.107. See Chapter 173-60 Washington Administrative Code (WAC). LOT 9 - SITE PLAN 1" = 10'-0" HOURS OF WORK: 7 AM to 8 PM Mon-Fri and 9 AM to 6 PM Sat. No work Sundays & holidays (per KZC 115.25). Exceptions must be approved in writing by Planning Official. LOT 8 HEIGHT CALCULATION A B C D 99.9 98.3 97.7 99.7 a b c d AVERAGE GRADE MAX. HEIGHT 30 46.67 30 46.67 2997 4588 2928 44653 153.33 15166.5 98.91 (98' - 10 7/8") 30 128.91 (128' - 10 7/8") A B C D 104.3 102.3 102.2 103.8 a b c d AVERAGE GRADE MAX. HEIGHT LOT 9 HEIGHT CALCULATION LOT 7 GARAGE 1ST FLOOR 2ND FLOOR 3RD FLOOR TOTAL 397 SF 884 SF 1280 SF 1223 SF 3784 SF LOT 8 GARAGE 1ST FLOOR 2ND FLOOR 3RD FLOOR TOTAL 397 SF 884 SF 1291 SF 1281 SF 3853 SF LOT 9 GARAGE 1ST FLOOR 2ND FLOOR 3RD FLOOR TOTAL 30 46.67 30 46.67 3129 4774 3066 4844 153.34 15814 103.125 (103' - 1 1/2") 30 133.125 (133' - 1 1/2") A B C D 107.7 104.1 105.7 107.4 2 STRUCTURAL ENGINEER: CORNELL E. BURT, P.E. BURT ENGINEERING PLLC 18530 MERIDIAN AVE. N. SHORELINE, WA 98133 P: 206.779.6856 F: E: CB@BURTENGINEERING.COM a b c d 30 46.67 30 46.67 3231 4858 3171 5012 153.34 16273 REGISTRATION: EMILY D. BUCHWALTER ZONING & CODE INFORMATION STATE OF WASHINGTON SINGLE FAMILY SET BACKS REQUIRED: FRONT YARD - 20'-0" SIDE YARD - 5'-0" REAR YARD - 10'-0" SET BACKS PROVIDED: 397 SF 765 SF 1143 SF 1165 SF (-100) SF 3370 SF LOT 9 GARAGE 1ST FLOOR 2ND FLOOR 3RD FLOOR INTERNAL STAIRCASE TOTAL 397 SF 765 SF 1133 SF 1165 SF (-100) SF 3360 SF CREDIT 5 1 1 2 7 3 3 OCCUPANCY: QT. SECT. MAP 1" = NTS FRONT YARD - 20'-0" SIDE YARD - 5'-0" REAR YARD - 10'-0" BUILDING CLASSIFICATION A. OCCUPANCY CLASSIFICATION: SINGLE FAMILY RESIDENCE B. TYPE OF CONSTRUCTION: 1. AUTOMATIC SPRINKLERS PROVIDED __ YES X NO 2. TYPE OF CONSTRUCTION: TYPE V-B BUILDING, ELECTRICAL, MECHANICAL, AND PLUMBING ARE INCLUDED WITH THIS PERMIT CODE INFORMATION ALL MATERIALS, WORKMANSHIP, DESIGN AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE FOLLOWING APPLICABLE CODES USED IN THIS DESIGN FOR CITY OF KIRKLAND. 2012 INTERNATIONAL BUILDING CODE (IBC) 2012 INTERNATIONAL RESIDENTIAL CODE (IRC) 2012 INTERNATIONAL MECHANICAL CODE (IMC) 2012 INTERNATIONAL FUEL GAS CODE (IFGC) 2012 INTERNATIONAL FIRE CODE (IFC) WASHINGTON STATE ENERGY CODE, WAC 51-11 (WSEC) 2012 UNIFORM PLUMBING CODE (UPC) 2012 NATIONAL ELECTRIC CODE (NEC) 2012 NATIONAL FUEL GAS CODE (NFGC) NFPA 54, WAC ENERGY CODE COMPLIANCE GENERAL PRESCRIPTIVE METHOD SEE SHEET A0.1 & A5.0 HEAT SOURCE SYSTEM: 95% FORCED AIR FURNACE TABLE 6-1: 5b MAX. HEIGHT 106.12 (106' - 1 9/32") 30 136.12 (136' - 1 9/32") LOT SIZE +/- 0.22 ACRES 0.22 X 30 = 6.6 REQUIRED MINIMUM TREE DENSITY = 7 TREE CREDITS TREE CREDIT RETAINED = 0 SUPPLEMENTAL TREES REQUIRED = 7 Issue Date INTAKE DATE: PARCEL LOCATION DUNCANS ADD TO KIRKLAND PLat Block: 1 Plat Lot: 7-8-9 397 SF 765 SF 1151 SF 1164 SF (-100) SF 3377 SF ACTION REMOVE REMOVE REMOVE REMOVE REMOVE REMOVE CITY OF KIRKLAND PLA6D 212020-0035 ARCHITECTURAL SHEET INDEX A0.0 A0.1 A0.2 A1.0 A2.0 A2.1 A2.2 A3.0 A4.0 A4.1 A4.2 A5.0 A6.0 A6.1 A6.2 A6.3 A6.4 COVER SHEET & SITE PLAN GENERAL NOTES SCHEDULES FOUNDATION PLAN 1ST FLOOR PLAN 2ND FLOOR PLAN 3RD FLOOR PLAN ROOF PLAN ELEVATIONS ELEVATIONS PERSPECTIVES SECTION DETAILS DETAILS DETAILS DETAILS DETAILS DATE: REVISIONS: 1. CRAWL SPACE 2. 3. 4. 5. 8-29-14 PROJECT / CLIENT: TERRI BELLA RESIDENCES 3 SISTERS LLC 335 PARKPLACE CENTER G119 KIRKLAND, WA 98033 JOB ADDRESS: 328 4TH AVE. S KIRKLAND, WA 98033 LOT 9 - EAST UNIT DRAWING NAME: STRUCTURAL SHEET INDEX TITLE SHEET/ SITE PLAN S0.0 S1.1E S1.2E S1.3E S2.1 S2.2 S2.3 S2.4 S2.5 S2.6 Drawn By: US Checked By: EB Owner Approval: GENERAL NOTES FOUNDATION AND FIRST FLOOR FRAMING PLANS SECOND AND THIRD FLOOR FRAMING PLANS ROOF FRAMING PLAN FOUNDATION SECTIONS FOUNDATION SECTIONS SCHEDULES FLOOR FRAMING SECTIONS FLOOR FRAMING SECTIONS ROOF FRAMING SECTIONS CIVIL SHEET INDEX 1 2 3 4 5 6 7 SITE PLAN T.E.S.C. PLAN 4TH AVENUE SOUTH PLAN & PROFILE NOTES DETAILS 1 DETAILS 2 DETAILS 3 PHASE: PERMIT SET This drawing is the exclusive property of medici architects, and can be reproduced only with the permission of the architect. variations and modifications to work shown on this drawing shall not be carried out without written permission from the architect. APPROVED FOR CONSTRUCTION: LANDSCAPE SHEET INDEX OPTION 3a & 4 for 1.5 CREDITS L1.0 AVERAGE GRADE REGISTERED ARCHITECT 6926 LEGAL DESCRIPTION: LOT 8 GARAGE 1ST FLOOR 2ND FLOOR 3RD FLOOR INTERNAL STAIRCASE TOTAL DBH 18 6 9 10, 10 13,12,10,13 15 VICINITY MAP 1" = NTS 11661 SE1st Street, Suite 200 Bellevue, Washington 98005 Tel: (425) 453-9298 Fax: (425) 452-8448 PROJECT DESCRIPTION NEW SINGLE FAMILY RESIDENCE JURISDICTION: ZONING: PARCEL ASSESSOR'S #: 397 SF 884 SF 1281 SF 1281 SF 3843 SF LOT 7 GARAGE 1ST FLOOR 2ND FLOOR 3RD FLOOR INTERNAL STAIRCASE TOTAL TREE # TREE#101 TREE#102 TREE#103 TREE#104 TREE#105 TREE#106 PROJECT LOCATION THIS PROJECT IS SUBMITTED UNDER THE APPROVAL OF ZON07-00024. TREE DENSITY CALCULATION LOT 7 HEIGHT CALCULATION City of Kirkland Reviewed by R Braun 03/11/2015 ARCHITECT: MEDICI ARCHITECTS EMILY BUCHWALTER, AIA 11661 SE 1ST STREET, SUITE 200 BELLEVUE, WA 98005 P: 425.453.9298 F: 425.452.8448 E: EMILY@MEDICIARCHITECTS.COM F.A.R. CALCULATION 110' 0" 109 '-0 0" DRY WELL OVERFLOW CATCH BASIN 6" SD IE=101.0 PER CIVIL DRAWINGS 108' 0" 107 '- 106' 0" DRY WELL OVERFLOW CATCH BASIN 6" SD IE=98.0 PER CIVIL DRAWINGS - 0" CB RIM=101.59 IE=98.59 (12" IN-E) IE=94.70 (12" IN-N) IE=94.70 (12" IN-W) BENCH MARK 105' 104 '-0 " 10 '3 -0 " DRY WELL OVERFLOW CATCH BASIN 6" SD IE=96.5 PER CIVIL DRAWINGS 1 120.00' 1244 SF 87 SF 63 SF 14 SF 394 SF 82 SF 0 SF 1884 SF 58.87 % NO SPECIAL REGULATION ON MULTI FAMILY RESIDENTIAL ZONE PLA6D 102' - 0" 101' - 0" STUB TO ROOF, DRIVEWAY AND FOOTING DRAINAGE (TYP) PER CIVIL DRAWINGS 2.0 % 5' - 0" 2.0 % TREE # 7 BOTTOM EL=91.7 1236 SF 87 SF 63 SF 14 SF 394 SF 82 SF 0 SF 1876 SF 58.62 % TREE #202 5'-0" MIN. CONCRETE WALKWAY 82 SF LOT 9 HOUSE FOOTPRINT FRONT ENTRY REAR PATIO ROOF OVERHANG > 18" DRIVEWAY FRONT WALKWAY (CONCRETE) 100% UNCOVERED REAR PATIO TOTAL OF EXISTING LOT Architecture Programming Accessible Design Interior Design CONTRACTOR: WACHTLER MARSHALL, INC. 335 PARKPLACE CENTER SUITE G119 KIRKLAND, WA 98033 P: 253.381.1107 F: 253.225.1904 E1: WACHTLERMARSHALL@GMAIL.COM E2: DAN.WACHTLER@GMAIL.COM FIRE CALCULATION N00'36'24"W 4" SD IE=100.0 PER CIVIL DRAWINGS 2.0 5' - 0" PROPERTY LOT LINE PROPERTY LOT LINE PROPERTY LOT LINE 5' - 0" FRONT ENTRY 87 SF D - 107.4' 112' - 0" LINE OF FRONT SETBACK FROM PROPERTY LINE B - 104.1' 111' -0" 4" SD TREE #103 IE=97.0 PER CIVIL DRAWINGS TREE #102 HOUSE FOOTPRINT 1236 SF 110' -0" 5' - 0" 109' -0" TREE #101 80.00' LOT 7 PROPERTY LOT LINE 80.00' TREE #203 4" SD FRONT IE=95.7 PER CIVIL ENTRY DRAWINGS 87 SF OWNERS: 3 SISTERS LLC LOT 8 HOUSE FOOTPRINT FRONT ENTRY REAR PATIO ROOF OVERHANG > 18" DRIVEWAY FRONT WALKWAY (CONCRETE) 100% UNCOVERED REAR PATIO TOTAL OF EXISTING LOT REAR SETBACK 5' - 0" REAR PATIO 63 SF LOT SIZE: 3200SF LOT COVERAGE ALLOWABLE = 60%: 1920 SF BUILDABLE AREA WITH SETBACKS: 1500 SF 120.00' 10' - 0" " 103' - 0" 10 2' - 0 0" 101' - 1 -' 0 9'0" TREE #205 PROPERTY LOT LINE PROJECT DATA LOT 7 HOUSE FOOTPRINT FRONT ENTRY REAR PATIO ROOF OVERHANG > 18" DRIVEWAY FRONT WALKWAY (CONCRETE) 100% UNCOVERED REAR PATIO TOTAL OF EXISTING LOT JOB SITE 9 98' - 0" 97' - 0" LOCALIZED FILL MAY BE REQ'D AS PART OF THE INFILTRATION TRENCH INSTALLATION IN ORDER TO MAINTAIN MIN. COVER OVER THE 6" DIAMTER TRENCH OVERFLOW PIPE. PER CIVIL DRAWINGS LOT COVERAGE CALCULATION MEDICI ARCHITECTS PLANTING PLAN SURVEY 1 BOUNDARY AND TOPOGRAPHIC SURVEY PROJECT No.: 2014036 DATE/ TIME: CALL 48 HOURS BEFORE YOU DIG 1-800-424-5555 2/11/2015 1:32:42 PM PLOT SCALE: 1:1 A0.0 DIVISION 1 - GENERAL REQUIREMENTS: THERMAL INSULATION: DIVISION 9 - INTERIOR FINISHES: THE GENERAL CONTRACTOR SHALL REVIEW THE CONSTRUCTION DOCUMENTS TO COMPLETE THE WORK AND NOTIFY THE ARCHITECT OF RESOLUTION FOR ALL DISCREPANCIES BETWEEN ARCHITECTURAL DRAWINGS, STRUCTURAL DRAWINGS AND CIVIL DRAWINGS PRIOR TO CONSTRUCTION. (PER WSEC 2012 TABLE R402.1.1, REFER TO TABLE FOOTNOTES FOR ADDITIONAL INFORMATION) FENESTRATION U-FACTOR .30 SKYLIGHT U-FACTOR .50 GLAZED FENESTRATION SGHC NR CEILING R-VALUE 49 WOOD FRAME WALL R-VALUE 21 INT (FRAMING @ 16" O.C., R-10 MIN. @ HEADERS) MASS WALL R-VALUE 21 / 21 FLOOR R-VALUE 30 BELOW GRADE WALL R-VALUE 21 INT (FURRED WALL FRAMING @ 16" O.C.,) + THERMAL BREAK BETWEEN SLAB AND BASEMENT WALL. SLAB R-VALUE & DEPTH 10, 2FT. (FOR HEATED SLABS, INSULATION TURNED UP SIDES & CONTINUOUS UNDER ENTIRE SLAB). GYPSUM DRYWALL: SMOOTH FINISH 1/2" GWB ON WALLS AND CEILINGS; 5/8" GWB ON ANY CEILINGS WITH FRAMING @ 24" O.C. PROVIDE GYPSUM DRYWALL CONSTRUCTION FIRE RESISTANT RATINGS INDICATED INSTALL WATER- RESISTANT BACKING BOARD IN BATHROOMS AND OTHER SIMILAR “WET” AREAS NOT OTHERWISE INDICATED TO REVIVE “WONDERBOARD” AND TILE. INSTALL COMPOUND IN 3 COATS (PREFILL OF CRACKS RECOMMENDED BY MANUFACTURE); SAND AFTER LAST 2 COATS. ATTACHMENTS: SCREW (ABSOLUTELY NO NAILS) ACCESSORIES AND TAPE: AS RECOMMENDED BY GYPSUM BOARD MANUFACTURE AND AS INDICATED IN THE DRAWINGS. JOINT COMPOUND: UNITED STATES GYPSUM CO. USE WATER-RESISTANT JOINT COMPOUND WITH WATER RESISTANT BACKING BOARD. FINISH: SMOOTH-WALLS REGLETS AND BEADS: VERIFY WITH ARCHITECT & OWNER AS REQUIRED. ACOUSTIC INSULATION: PROVIDE ACOUSTIC INSULATION AT ALL CEILINGS AND OUTER WALLS OF BEDROOMS, BATHROOMS AND LAUNDRY ROOMS. WALLS: R-19 ACOUSTIC BATT INSULATION IN 2X6 WALLS R-13 ACOUSTIC BATT INSULATION IN 2X4 WALLS CEILINGS: R-19 ACOUSTIC BATT INSULATION HARDWOOD FLOORING: TO BE SELECTED BY OWNER. APPLY (3) COATS SWEDISH FINISH. INSTALL FLUSH WOODEN FLOOR GRILLES PER MECHANICAL REQUIREMENTS FOR AIR VENTING. VERIFY LOCATION OF GRILLES WITH ARCHITECT & OWNER. DO NOT SCALE DRAWINGS - NOTIFY ARCHITECT OF DIMENSIONS IN QUESTION. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CHECKING AND REVIEWING THE BUILDING DEPARTMENT APPROVED SET OF CONSTRUCTION DOCUMENTS. THE ARCHITECT SHALL BE PROMPTLY NOTIFIED OF REQUIRED CHANGES; AT THAT TIME, THE ARCHITECT WILL INITIATE APPROPRIATE ACTION. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR DISSEMINATING ALL INFORMATION CONTAINED IN THE DRAWINGS, SPECIFICATIONS AND BID DOCUMENTS TO EACH SUBCONTRACTOR. INSTALLATION OF MATERIALS: ALL PRODUCTS IN THE DRAWINGS OR INTERIOR SPECIFICATIONS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S CURRENT PUBLISHED INSTRUCTIONS. MANUFACTURER'S INSTRUCTIONS IN CONFLICT WITH THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF THE WORK. PRODUCTS NOT PROVIDED WITH INSTALLATION INSTRUCTIONS SHALL BE INSTALLED IN ACCORDANCE WITH THE BEST TRADE PRACTICES OF THE INDUSTRY. IN ANY CASE, WORKERS EXPERIENCED AND SKILLED IN THE INSTALLATION OF THESE ITEMS SHALL INSTALL ALL PRODUCTS. APPROVAL OF SUBSTITUTIONS: THE GENERAL CONTRACTOR SHALL SUPPORT SUBSTITUTION REQUESTS FOR SPECIFIED MATERIALS WITH COMPLETE DATA, DRAWINGS AND SAMPLES AS NECESSARY FOR REVIEW BY THE ARCHITECT AND OWNER. ALLOW TIME FOR INVESTIGATION BEFORE A DECISION MUST BE MADE. WHEN THE ARCHITECT APPROVES A SUBSTITUTION, IT IS WITH THE UNDERSTANDING THAT THE GENERAL CONTRACTOR GUARANTEES THE SUBSTITUTED ARTICLE TO BE EQUAL OR BETTER THAN THE ONE SPECIFIED. ANY CHANGES TO THE CONTRACT SHALL BE DONE BY CHANGE ORDER. DIVISION 2 - SITE WORK: THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS BEFORE PROCEEDING. ANY VARIATION FROM THE DRAWINGS AND DIMENSION DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. PRIOR TO ANY FIELD CHANGES THERE MUST BE APPROVAL FROM THE ARCHITECT. SITE EXCAVATION, BACKFILL, AND FINISH GRADING: EXCAVATION SITE TO GRADES AS SHOWN ON DRAWINGS (NOTIFY ARCHITECT OF ANY DEVIATIONS). REMOVE ALL EXCESS MATERIAL FROM SITE. DO NOT ASSUME ON-SITE MATERIAL ACCEPTABLE FOR BACKFILL. PLACE WASHED GRAVEL AS SHOWN. PROVIDE COMPACT FILL UNDER SLABS PER STRUCTURAL ENGINEERS SPECIFICATIONS. FINISH-GRADE SITE FOR LAWN. CONCRETE STAIRS: PROVIDE NEW CONCRETE STAIRS AS INDICATED ON DRAWINGS. PREPARE GRADE, FILL, AND COMPACT ANY SOFT AREAS. PLACE 4" PAVING OVER 2" CRUSHED ROCK AND SLOPE TO DRAINS AS INDICATED ON SITE PLAN, SHEET A0.0. SITE UTILITIES: RELOCATE EXISTING UTILITIES AS REQUIRED TO ACCOMMODATE NEW RESIDENCE AS INDICATED ON DRAWINGS. COORDINATE DISCONNECTION OF UTILITIES WITH OWNER & CITY OF MUKILTEO. THE SIDE SEWER MUST BE CAPPED IN THE PRESENCE OF A UTILITY INSPECTOR. THE CAPPING MUST BE AT THE PROPERTY LINE; OR AT THE SEWER MAIN IF ON THE PROPERTY. ANY TEST TEES MUST BE REMOVED. A SIDE SEWER PERMIT IS REQUIRED FOR RECONNECTION. A WATER SERVICE APPLICATION IS REQUIRED TO UPGRADE EXISTING METER. SITE DRAINAGE: CONNECT ALL DOWNSPOUTS TO STORM SYSTEM PER CIVIL DRAWINGS. DIVISION 3 - CONCRETE: FOUNDATIONS: PATCH ROCK PACKETS WHEN ABOVE GRADE WITH SACK FINISH. SEE STRUCTURAL GENERAL NOTES FOR SUPPLEMENTAL INFORMATION. CAST-IN-PLACE ARCHITECTURAL CONCRETE: ALL CONCRETE SHALL BE MIXED, PROPORTIONED CONVEYED, AND PLACED IN ACCORDANCE WITH IRC SECTIONS R402.2 AND R403. PROVIDE NEW CONCRETE PATIO AND WALKWAY WITH CONTROL JOINTS AS INDICATED ON DRAWINGS. PREPARE GRADE, FILL, AND COMPACT AND SOFT AREAS. SEE STRUCTURAL PLANS AND NOTES. DIVISION 4 - MASONRY: NOT USED BUILDING WRAP: WRAP ENTIRE BUILDING WITH 15 LB ASPHALT-IMPREGNATED FELT. OR OTHER PRODUCT APPROVED BY SIDING MANUFACTURE FOR SPECIFIC SIDING MATERIAL SUCH AS HARDIE PANEL SIDING. SIDING: HARDIE PLANK HORIZONTAL LAP SIDING WITH 6", 8" & 4"/8" EXPOSURE, PAINTED WITH PAINTABLE SPLINE. SEE ELEVATIONS. CEDAR TIGHT KNOT LAP SIDING WITH 4" EXPOSURE - SEAL AND STAIN ALL SIDES BEFORE INTALLING @ ALL CUTS. FASTEN WITH STAINLESS STEEL FASTENERS. NORSTONE ROCK PANELS (3/4"-1 3/4") CHARCOAL. SEE ELEVATIONS FOR LOCATION. SOFFIT: EXTERIOR SOFFIT TO BE 4" HARDIE PANEL PAINTED WITH PAINTABLE SPLINE WHERE APPLICABLE PER IRC R302.1(1). INSTALL GALVANIZED METAL RAFTER CAPS AT EXPOSED RAFTER TAILS. EXTERIOR STRUCTURAL WOOD SEALER: STAIN EXPOSED WOOD BEAMS, OUTLOOKERS, COLUMNS, KNEE BRACES, RAFTER TAILS, ETC. WITH 2-COATS MINIMUM BENJAMIN MOORE "MOORWOOD" ALKYD SEMI-TRANSPARENT DECK AND SIDING STAIN OR EQUAL. COLOR TO BE DETERMINED. VERIFY W ARCHITECT / OWNER. WATERPROOF DECK: AT DECKSFIBERGLASS WATERPROOF MEMBRANE OVER 1/2 " THICK MARINE PLYWOOD OVER 3/4 " PLYWOOD, PLYWOOD MUST BE ACX CROSS-PLUGGED (NO TONGUE AND GROOVE) UNDERLAYMENT, PLYWOOD SUBSTRATE SHOULD BE INSTALLED JUST PRIOR TO FIBERGLASS LAMINATION PROCESS, PLYWOOD MUST NOT BE ALLOWED TO ABSORB ANY MOISTURE WHAT SO EVER. AT EXPOSED DECKSEXPOSED LAYER OF FIBERGLASS MIXTURE TO INCLUDE SAND FOR UV PROTECTION AND PROVIDE SLIP RESISTANCE. FIBERGLASS WATERPROOF MEMBRANE OVER 1/2" THICK PLYWOOD OVER 3/4" PLYWOOD, PLYWOOD MUST BE ACX CROSS-PLUGGED (NO TONGUE AND GROOVE) UNDERLAYMENT, PLYWOOD SUBSTRATE SHOULD BE INSTALLED JUST PRIOR TO FIBERGLASS LAMINATION PROCESS, PLYWOOD MUST NOT BE ALLOWED TO ABSORB ANY MOISTURE WHAT SO EVER. LOCAL INSTALLER: AROUND THE SOUND, 6201 NE 175TH ST, KENMORE, WA 98028. CONTACT: JOE @206-719-7709. ROOFING MATERIAL: ARCHITECTURAL : MANUFACTURER: STYLE: COLOR: FASTENERS: ICE & WATER SHIELD: WEATHERBOND TPO - MECHANICALLLY ATACHED TO BE SELECTED BY OWNER INSTALL 36" WIDE ACROSS ALL HIPS AND VALLEYS, AND (2) 36" WIDE COURSES AT ALL EAVES UNDERLAYMENT: TYPE 30 PER ASTM D-226 VALLEY FLASHING: 28 GAUGE, ENAMELED, MIN. 24" "W"-FLASHING WALL TRAYS: 26 GAUGE, ENAMELED, MIN. 6" TROUGH ROOF TO WALL FLASHING: 26 GAUGE, ENAMELED, MIN. 4" COMP. COVERAGE PIPE FLASHING: 26 GAUGE, ENAMELED, MIN. 12" SKIRT CHIMNEY & SKYLIGHT FLASHING: 26 GAUGE, ENAMELED SADDLE WITH DIVERTER WHERE WIDTH EXCEEDS 2 FEET IN-WALL COUNTER FLASHING: 26 GAUGE, ENAMELED 7-BAR FLASHING * DELIVER AND INSTALL PER IRC SECTION R905 * DELIVER AND INSTALL PER IRC SECTION R905 DIVISION 5 - METALS: METAL FABRICATIONS: CUSTOM-FABRICATED METAL ITEMS INCLUDING EXTERIOR AND INTERIOR RAILINGS AND HANDRAILS TO BE APPROVED BY OWNER AND ARCHITECT, INSTALLED BY CONTRACTOR. ALL EXPOSED STRUCTURAL METAL CONNECTORS TO BE POWDER COATED, UNLESS NOTED OTHERWISE. COLOR TO BE DETERMINED. PROVIDE NEOPRENE GASKET AT ALL DISSIMILAR METAL CONNECTIONS, TYP. STRUCTURAL STEEL AND METAL FABRICATION REFER TO AND COMPLY WITH STRUCTURAL ENGINEERING NOTES, SPECIFICATION AND DRAWINGS. PROVIDE SHOP DRAWINGS SHOWING DETAILS OF FABRICATION, ASSEMBLY AND INSTALLATION INCLUDING TEMPLATES FOR ANCHOR BOLT PLACEMENT. GRIND SMOOTH EXPOSED WELDS. STEEL FINISHES: EXTERIOR STEEL UNLESS NOTED OTHERWISE - GALVANIZED, INCLUDING ALL BOLTS, NUTS AND WASHERS. INTERIOR STEEL - SEE SHOP DRAWINGS DIVISION 6 - WOODS & PLASTICS: REFER TO AND COMPLY WITH STRUCTURAL ENGINEERING NOTES, SPECIFICATION AND DRAWINGS. PROVIDE BLOCKING FOR PLUMBING FIXTURES, BATH ACCESSORIES AND ELECTRICAL DEVICES.PER R317.4 WOOD/PLASTIC COMPOSITES USED IN EXTERIOR DECK BOARDS, STAIRS TREADS, HANDRAILS AND GUARD RAIL SYSTEMS SHALL BEAR A LABEL INDICATING THE REQUIRED PERFORMANCE LEVELS AND DEMONSTRATING COMPLIANCE WITH THE PROVISIONS OF ASTM D 7032. TREATED WOOD: PRESSURE TREATED LUMBER AND PLYWOOD WITH WATER-BORN PRESERVATIVES FOR WOOD TO MASONRY, WOOD TO STRUCTURAL STEEL CONTACT AND AS SPECIFICALLY NOTED IN THE DRAWINGS. STRUCTURALLY GLUED LAMINATED UNITS: REFER TO AND COMPLY WITH STRUCTURAL ENGINEERING NOTES, SPECIFICATION AND DRAWINGS. SEAL ALL SURFACES, INCLUDING CUT ENDS AND DRILLED BOLT HOLES PRIOR TO PLACING MEMBERS. ALL EXPOSED TO WEATHER UNITS TO BE TREATED. FINISH CARPENTRY: COMPLY WITH AWI QUALITY STANDARDS “CUSTOM”, UNLESS INDICATED OTHERWISE. USE ONLY SEASONED LUMBER. CONCEAL FASTENERS WHEREVER POSSIBLE, EXCEPT WHERE EXPOSED FASTENERS ARE SHOW. HOT-DIP GALVANIZED OR STAINLESS STEEL FASTENERS FOR WORK EXPOSED TO EXTERIOR AND HIGH HUMIDITY. INSTALL EXTERIOR TRIM WITH MINIMAL POSSIBLE NUMBER OF JOINTS. CENTER JOINTS OVER VERTICAL MEMBERS WHEREVER POSSIBLE. STAGGER JOINTS IN ADJACENT RELATED MEMBERS. COPING TO RETURN, MITER AT CORNERS TO PRODUCE TIGHT FITTING JOINTS. USE SCARF JOINTS FOR END TO END JOINTS, INSTALL WITH FLUSH APPEARANCE. KERF BACKS AS REQUIRED TO AVOID WARPING. HAND SELECT LUMBER FOR INTERIOR TRIM OF SIMILAR GRAIN AND COLORATION. PRE-STAIN SEAL AND FINISH PER OWNER. STAIRWAY CONSTRUCTION: CONSTRUCT ALL STAIRS IN ACCORDANCE WITH IRC SECTION R311.7, AND AS DETAILED ON THE DRAWINGS. FIREBLOCKS: INSTALL FIRE BLOCKING IN WALL/CEILING LINE OF CONCEALED SOFFIT SPACES AND 10-FOOT INTERVALS BOTH VERTICAL AND HORIZONTAL, PER IRC SECTION R302.11. DRAFTSTOPS: INSTALL DRAFTSTOPS (IN COMMON WALLS SEPARATING LIVING UNITS AND ATTICS) PER IRC SECTION R302.12. FIRESTOPS: INSTALL DWELLING UNIT RATED PENETRATIONS PER IRC R302.4. DIVISION 7 - THERMAL & MOISTURE PROTECTION: MOISTURE CONTROL: PER WSEC R301.1. FOUNDATION WALL DAMPROOFING: APPLY ASPHALTIC EMULSION TO ALL BELOW-GRADE FOUNDATION WALLS. ALL BELOW-GRADE FOUNDATION WALLS GREATER THAN 48" HIGH SHALL ALSO BE PROTECTED WITH DRAINAGE MATTING (MIRRODRAIN, DELTA-DRAIN, ENKADRAIN, OR APPROVED EQUAL). FOUNDATION WALL WATERPROOFING: ALL BELOW-GRADE FOUNDATION WALLS TO BE SPRAYED WITH GRAYWALL WATERPROOFING BY RUBBER POLYMER CORPORATION. THE MEMBRANE SHALL BE APPLIED TO A MINIMUM THICKNESS OF 40-MILS TO EXTERIOR SURFACES WHICH ARE CLEAN AND DRY, AND THE AMBIENT AIR TEMPERATURE IS 15° F OR ABOVE. FILL HONEYCOMBED AREAS, CRACKS, AND TIE-HOLES WITH NON-SHRINKING GROUT BEFORE APPLYING THE MEMBRANE. ALL FOUNDATION WALLS GREATER THAN 48" HIGH (BELOW GRADE) SHALL ALSO BE PROTECTED BY DELTA-DRAIN DAMPPROOFING MEMBRANE BY COSELLA-DORKEN PRODUCTS, INC. SUPPLY ALL SYSTEM COMPONENTS INCLUDING DELTA-MS SHEET BARRIER, DELTA TERMINATION BAR, DELTA MOLDING STRIP, DELTA PLUG-AND-NAIL, AND ALL APPLICABLE SEALANTS. STONE FLOORING: WHERE APPLICABLE, INSTALL FLUSH WOODEN FLOOR GRILLES PER MECHANICAL REQUIREMENTS. VERIFY LOCATION OF GRILLES W/OWNER. BUILT-IN CABINETRY: VERIFY W/OWNER. INTERIOR STONE WORK/ HARD SURFACE COUNTERTOPS: WHERE APPLICABLE, COMPLY WITH RECOMMENDATION CONTAINED IN NATIONAL GRANITE QUARRIES ASSOC., INC. (NBGQA). STONE SLAB: NOT YET DETERMINED, VERIFY WITH OWNER. GROUT: HYDROMENT, COLOR AS SELECTED BY OWNER. SEALANTS: AS RECOMMENDED BY INSTALLER. INTERIOR WOOD TRIM: ALL INTERIOR WOOD TRIM TO BE MDF UNLESS NOTED OTHERWISE. VERIFY W/OWNER. BASEBOARD TRIM: ENTIRE RESIDENCE FIRST FLOOR SHALL HAVE A 1/2 X 5 VERIFY W/OWNER MDF BASEBOARD TRIM. ROOMS WITH CERAMIC TILE FLOORING SHALL HAVE A CERAMIC TILE BASE. VERIFY W/OWNER. TILE: COMPLY WITH MORTAR AND GROUT MATERIALS AND INSTALLATION STANDARD OF THE AMERICAN NATIONAL STANDEE INSTITUTE (ANSI) STANDARD SPECIFICATION FOR CERAMIC TILE AND MANUFACTURER'S INSTRUCTIONS FOR GLASS MESH MORTAR UNITS (WONEDERBOARD) PER MANUFACTURE'S REQUIREMENT AT BATHROOMS. VERIFY EXPOSED EDGE OF THE TILE MEETING CARPET, WOOD, OR RESILIENT FLOORING, UNLESS OTHERWISE INDICATED. GROUT: HYDROMENT, COLOR AS SELECTED BY OWNER. SEALANTS: ONE -PART MILDEW-RESISTANT SILICONE SEALANTS PER MANUFACTURE. PAINT SPECIFICATIONS: VERIFY ALL FINISH WITH OWNER PRIOR TO PROCEEDING. COLORS WILL BE SELECTED BY OWNER FROM STANDARD COLOR AVAILABLE FOR THE COATINGS REQUIRED. APPLY REQUIRED PRIME COAT TO MATERIALS. PROVIDE BARRIER COATS OVER INCOMPATIBLE PRIMERS WHERE REQUIRED. PROVIDE FINISH COATS WHICH ARE COMPATIBLE WITH PRIMERS. SAND LIGHTLY BETWEEN LACQUER COATS. APPLY ADDITIONAL CATS UNTIL PAINT FILM IS OF UNIFORM FINISH, COLOR AND APPEARANCE. PRIMED AND PAINTED METAL: FIRST COAT: POLY-AMIDE EPOXY SECOND COAT: ALIPHATIC POLYESTER FINISH COAT: URETHANE GALVANIZED STEEL: EXPOSED EXTERIOR GALVANIZED STEEL LEFT UNPAINTED. EXTERIOR: DECKING, SIDING, EXTERIOR CEDAR TRIM AND SOFFIT BOARDS: SEE SPECIFICATION - DIVISION 6 - WOOD AND PLASTICS SECTION. WOOD PAINTED DOORS: PRIME AND TWO COATS BENJAMIN MOORE IMPREVO. COLOR TO BE SELECTED BY OWNER. WOOD LACQUER DOORS: TWO COATS TINTED SEMI-TRANSPARENT UV RESISTANT LACQUER. - COLOR TO BE SELECTED BY OWNER. INTERIOR WOOD TRIM: TWO COASTS CLEAR SEMI-GLOSS TRANSPARENT UV RESISTANT LACQUER OR PRIME AND TOW COAST OIL BASED SEMI-GLOSS ENAMEL. REVIEW WITH OWNER LOCATIONS OF PAINT VERSUS LACQUER. GWB: FIRST COAT: PVA SEALER-PRIMER SECOND COAT: INTERIOR FLAT LATEX (SEMI-GLOSS LATEX ENAMEL IN WET LOCATIONS) THIRD COAT: INTERIOR FLAT LATEX (SEMI-GLOSS AT WET LOCATIONS). INTERIOR WOOD PANELS: TWO COATS SHOP APPLIED CLEAR TINTED SEMI-TRANSPARENT UV RESISTANT LACQUER. TOUCH UP FIELD CUTS AS REQUIRED. VERIFY W/OWNER. DIVISION 10 - SPECIALTIES: TOWEL & BATH ACCESSORIES: VERIFY W/OWNER SPECS. FOR ALL MIRRORS, TOWEL BARS, TOILET PAPER DISPENSERS AND ANY OTHER ACCESSORIES, WHETHER SHOWN ON PLANS OR NOT. PROVIDE BLOCKING FOR ALL ACCESSORIES AS INDICATED ON DRAWINGS. STORAGE SYSTEMS: CONSULT WITH OWNER ON CLOSET STORAGE SYSTEMS. ATTIC SPACES: PER IRC SECTION R807.1. BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF CONSTRUCTION SHALL HAVE AN ATTIC ACCESS OPENING TO ATTIC AREAS THAT EXCEED 30 SQUARE FEET AND HAVE A VERTICAL HEIGHT OF 30 INCHES OR GREATER. THE VERTICAL HEIGHT FROM THE TOP OF THE CEILING FRAMING MEMBERS TO THE UNDERSIDE OF THE ROOF FRAMING MEMBERS. SMOKE & CARBON MONOXIDE DETECTORS: SEE SHEETS A2.0, A2.1. PROVIDE AND INSTALL SMOKE DETECTORS PER IRC SECTION R314. HARDWIRE 110-VOLT UNIT WITH BATTERY BACKUP. IN ALTERATIONS, REPAIRS AND ADDITIONS PROVIDE AND INSTALL ADDITIONALLY PER IRC SECTION R314. PROVIDE AND INSTALL CARBON MONOXIDE DETECTORS PER IRC SECTION R315. WALL MOUNTED LIGHT FIXTURES: ALL WALL MOUNTED FIXTURES SHALL BE MOUNTED +80" FROM FINISH FLOOR TO CENTERLINE OF FIXTURE, UNLESS NOTED OTHERWISE. AT BOTTOM LIGHT VALENCE, LIGHT FIXTURE SHALL BE MOUNTED AT +84" AND TOP OF MIRROR SHALL BE AT +80". EAVES: PROVIDE WATERPROOF DUPLEX OUTLETS UNDER THE EAVES. COLOR SHALL BE APPROVED BY ARCHITECT & OWNER. BUILT-IN IRONING BOARD: N/A DOOR CHIME: PROVIDE WIRED DIMANGO DOOR CHIME AND PUSH BUTTON; STYLE AND COLOR TO BE DETERMINED. VERIFY W/OWNER. INTERNAL MEDIA WIRING: VERIFY AND PROVIDE TELEPHONE, CABLE, AND INTERNET REQUIREMENTS PER OWNER. GROUND FAULT CIRCUIT INTERRUPTER PROTECTION: GROUND FAULT INTERRUPTER REQUIRED IN ALL BATHROOMS, ON OR ABOVE COUNTERTOPS WITHIN SIX FEET OF ANY SINK, IN ALL ACCESSIBLE GARAGE AREAS, IN ALL CRAWL SPACES, ALL OUTDOOR AREAS, AND ANY OTHER LOCATIONS AS REQUIRED BY THE NEC. SWITCHES/OUTLETS AND COVER PLATES: ALL SWITCHES AND OUTLETS SHALL BE BLOCKED OUT FROM OPENINGS SUCH THAT COVER PLATES WILL NOT CONFLICT WITH DOOR AND WINDOW TRIM OR DECORATIVE MOLDING, UNLESS NOTED OTHERWISE. SUPPLY AND INSTALL COVER PLATES ON ALL ELECTRICAL, TELEPHONE, AND CABLE OUTLETS. ALL COVER PLATES SHALL BE DECORA OR EQUAL; COLOR TO BE DETERMINED. EXCEPTION: THE TOTAL LEAKAGE TEST IS NOT REQUIRED FOR DUCTS AND AIR HANDLERS LOCATED ENTIRELY WITHIN THE BUILDING THERMAL ENVELOPE. DUCTS LOCATED IN CRAWL SPACES DO NOT QUALIFY FOR THIS EXCEPTION. 2. A RESIDENTIAL ENERGY COMPLIANCE CERTIFICATE COMPLYING WITH WSEC 401.3 IS REQUIRED TO BE COMPLETED BY THE DESIGN PROFESSIONAL OR BUILDER AND PERMANENTLY POSTED WITHIN 3' OF THE ELECTRICAL PANEL PRIOR TO THE FINAL INSPECTION. 3. MINIMUM 75% OF ALL INTERIOR LUMINARIES SHALL BE HIGH EFFICACY LUMINARIES AND ALL EXTERIOR LIGHTING SHALL BE HIGH EFFICACY LUMINARIES. DIVISION 8 - DOORS AND WINDOWS: METAL DUCTS: JOINTS TAPED, INSULATED PER WSEC 403.2. *TPZ FENCES MUST BE INSPECTED PRIOR TO THE BEGINNING OF ANY CONSTRUCTION ACTIVITIES. WINDOWS: ALL WINDOWS TO BE DOUBLE-PANED, VINYL - ANODIZED BRONZE FINISH, WITH INSULATED LOW-E GLAZING. WINDOW PERFORMANCE AND CONSTRUCTION TO CONFORM WITH IRC SECTION R612. SIMULATED DIVIDED LITES SHALL HAVE 1" BEAD STOP PROFILE. HARDWARE FINISH SHALL MATCH DOOR HARDWARE. ALL CASEMENT OPENINGS SHALL HAVE ROTO HARDWARE. ALL OPENINGS WEATHER-STRIPPED BY MANUFACTURER; GENERAL CONTRACTOR SHALL INSTALL "Z"-FLASHING AT HEADS OF ALL WINDOWS AND SEAL WINDOW PERIMETER PER MANUFACTURER'S SPECIFICATIONS. PROVIDE INSECT SCREENS AT ALL OPERABLE LOCATIONS. EGRESS SHALL BE PROVIDED FROM ALL SLEEPING ROOMS PER IRC SECTION R310. GENERAL CONTRACTOR SHALL REVIEW ALL TEMPERED GLASS AND EGRESS LOCATIONS. PROVIDE SAFETY GLAZING PER IRC SECTION R308.4. U-VALUE OF ALL NEW WINDOW GLAZING TO BE 0.30 OR BETTER. PROVIDE LOEWEN, SIERRA PACIFIC, WEATHERSHIELD OR EQUAL, AS APPROVED BY ARCHITECT/OWNER. ACCESS DOORS: CRAWL SPACE AND ATTIC SPACE ACCESS DOORS: SEE FLOOR PLANS FOR SIZES AND LOCATION. 5. EACH DWELLING UNIT IS REQUIRED TO BE PROVIDED WITH AT LEAST ONE PROGRAMMABLE THERMOSTAT FOR THE REGULATION OF TEMPERATURE. TREE PROTECTION GUIDELINES ALL REMAINING TREES ARE TO HAVE A TREE PROTECTION ZONE (TPZ) ESTABLISHED BEFORE COMMENCEMENT OF ANY CONSTRUCTION OR DELIVERY ACTIVITIES. THE FOLLOWING GUIDELINES ARE TO BE OBSERVED AND PRACTICED DURING ALL CONSTRUCTION ACTIVITIES. *ACCESS IS TO BE RESTRICTED INTO TPZ'S WITH READILY VISIBLE TEMPORARY TREE FENCING ALONG THE LOD WHICH COMPLETELY SURROUNDS THE PROTECTED AREAS OF RETAINED TREES. FENCES SHALL BE CONSTRUCTED OF CHAIN LINK AND BE AT LEAST 4 FT TALL, CONSTRUCTED USING PIER BLOCK, AND MAJOR ROOTS SHOULD BE AVOIDED WHILE STAKING. REGISTERED ARCHITECT 6926 EMILY D. BUCHWALTER STATE OF WASHINGTON 2. ROUGH-IN TEST: TOTAL LEAKAGE SHALL BE LESS THAN OR EQUAL TO 4 CFM (113.3 L/MIN) PER 100 SQUARE FEET (9.29 M2) OF CONDITIONED FLOOR AREA WHEN TESTED AT A PRESSURE DIFFERENTIAL OF 0.1 INCHES W.G. (25 PA) ACROSS THE SYSTEM, INCLUDING THE MANUFACTURER'S AIR HANDLER ENCLOSURE. ALL REGISTERS SHALL BE TAPED OR OTHERWISE SEALED DURING THE TEST. IF THE AIR HANDLER IS NOT INSTALLED AT THE TIME OF THE TEST, TOTAL LEAKAGE SHALL BE LESS THAN OR EQUAL TO 3 CFM (85 L/MIN) PER 100 SQUARE FEET (9.29 M2) OF CONDITIONED FLOOR AREA. THE TEST RESULTS SHALL BE POSTED ON THE RESIDENTIAL ENERGY COMPLIANCE CERTIFICATE (WSEC 401.3). THIS SHALL BE PRESENT TO THE INSPECTOR AS A SIGNED AFFIDAVIT DOCUMENTING THE DUCT LEAKAGE TESTING RESULTS. *CONSTRUCTION MATERIALS OR SUPPLIES, SOIL, DEBRIS, VEHICLES, AND EQUIPMENT ARE NOT TO BE PARKED OR STORED WITHIN TPZ. INTERIOR DOORS: TO BE SELECTED BY OWNER. PROVIDE PRIVACY LOCKS AT ALL BATHROOMS AND BEDROOMS; PASSAGE LATCH AT ALL OTHERS UNLESS NOTED OTHERWISE; MATCHING HINGES TO MATCH LATCH SETS. VERIFY W/OWNER. PROVIDE 2 PAIR BUTTS ON ALL 8'-0" HIGH DOORS, 1-1/2 PAIR BUTTS ON 6'-8" OR 7'-0" DOORS. PROVIDE DOOR-STOPS TO MATCH HARDWARE. REGISTRATION: 1. POSTCONSTRUCTION TEST: TOTAL LEAKAGE SHALL BE LESS THAN OR EQUAL TO 4 CFM (113.3 L/MIN) PER 100 SQUARE FEET (9.29 M2) OF CONDITIONED FLOOR AREA WHEN TESTED AT A PRESSURE DIFFERENTIAL OF 0.1 INCHES W.G. (25 PA) ACROSS THE ENTIRE SYSTEM, INCLUDING THE MANUFACTURER'S AIR HANDLER ENCLOSURE. ALL REGISTER BOOTS SHALL BE TAPED OR OTHERWISE SEALED DURING THE TEST. LEAKAGE TO OUTDOORS SHALL BE LESS THAN OR EQUAL TO 4 CFM (133.3 L/MIN) PER 100 SQUARE FEET OF CONDITIONED FLOOR AREA. SOURCE SPECIFIC EXHAUST FANS: PROVIDE EXHAUST FANS WHERE SHOWN. DOOR HARDWARE: EXTERIOR DOORS: TO BE SELECTED BY OWNER, KEY LOCK EXTERIOR, KNOB LOCK INTERIOR, WITH SEPARATE DEAD BOLT TO MATCH. TO BE DETERMINED BY OWNER. 11661 SE1st Street, Suite 200 Bellevue, Washington 98005 Tel: (425) 453-9298 Fax: (425) 452-8448 1. DUCT LEAKAGE TEST RESULTS SHALL BE PROVIDED TO THE BUILDING INSPECTOR AND HOME OWNER PRIOR TO THE APPROVED FINAL INSPECTION. DUCTS SHALL BE LEAK TESTED IN ACCORDANCE WITH WSU RS-33, USING THE MAXIMUM DUCT LEAKAGE RATES SPECIFIED. DUCT TIGHTNESS SHALL BE VERIFIED BY EITHER OF THE FOLLOWING: CHIMNEY FLASHING: TAYLOR METAL PRODUCTS INC.USE MANUFACTURER RECOMMENDED OR EQUAL OR GREATER PERFORMING. GARAGE DOORS: SEE ELEVATIONS FOR PANEL PATTERN, CLOPAY ALUMINUM WITH CLEAR COAT, STYLE TO BE SELECTED BY OWNER. City of Kirkland Reviewed by R Braun 03/11/2015 ENERGY CODE COMPLIANCE NOTES: 4. PER REQUIREMENT FOR MEDIUM DWELLING UNIT, 1.5 ENERGY CREDIT POINTS MUST BE MET PER TABLE R406.2. OPTIONS 3a & 4 (HIGH EFFICIENCY HVAC DISTRIBUTION SYSTEM) ARE TO BE USED. INTERIOR DOORS: ALL SWINGING INTERIOR DOORS TO BE SOLID CORE, CLEAR COATED (BOTH SIDES) WOOD VENEER OR PAINTED BOTH SIDES. COLOR TO BE DETERMINED. VERIFY W ARCHITECT / OWNER. ALL POCKET-DOORS PREMIUM TRACK AND ROLLER HARDWARE. VERIFY W/OWNER. Architecture Programming Accessible Design Interior Design SOUND SPEAKERS: PROVIDE RECESSED SOUND SPEAKERS PER OWNER. GUTTERS AND DOWNSPOUTS: LAP EAVE FLASHING INTO GALVANIZED 6" SQUARE GUTTERS WITH MATCHING GALVANIZED DOWNSPOUTS DIVISION 11 - EQUIPMENT: CONNECTED TO 4" DIAMETER RIGID PVC TIGHTLINE AND RUN TO APPROVED DISCHARGE. CUSTOM FABRICATED RAKE AT GUTTER END - SOLDERED SEAM - 4" GALVANIZED DOWNSPOUTS WITH CUSTOM FABRICATED ATTACHMENTS. GARAGE DOOR OPENERS: VERIFY WITH ARCHITECT & OWNER FOR DOWNSPOUT LOCATIONS. ROOF/DECK DRAINS AND SCUPPERS SHALL BE PROVIDE 2 MIN. EACH INSTALLED PER IRC SECTION R903.4; CONCEALED PIPING SHALL BE INSTALLED IN ACCORDANCE WITH THE UPC. DIVISION 12 - FURNISHINGS: N/A ROOF VENTING: PER IRC SECTION R806, IECC CHP 4. R38 BATT INSULATION IN SINGLE RAFTER VAULTED & LOW SLOPE CEILINGS, R38 DIVISION 13 - SPECIAL CONSTRUCTION: N/A BATT INSULATION IN CEILINGS WITH ADVANCED FRAMING, AND R49 BATT INSULATION IN STANDARD FRAMING PROVIDE 1" AIR GAP AT TOP. DIVISION 14 - CONVEYING SYSTEMS: N/A USE BEST MATERIALS BRAND TPO/PVC ROOF VENT MODEL S-VS08 WHERE DRAWN. PROVIDE EAVE AND RAKE VENTING WHERE SHOWN. UN-VENTED CAVITY: 1.625" ICYNENE CLOSED-CELL WATER-BASED SPRAY FOAM INSULATION R-4.9 DIVISION 15 - MECHANICAL: PER INCH. SPRAY-IN WHERE SHOWN. HEATING AND VENTILATION: ROOF FLASHING: Kelvinator single stage gas furnace PROVIDE FLASHING AND OTHER WEATHER PROTECTION PER IRC SECTIONS R903 AND R905. VALLEY FLASHING SHALL Model KG7S w/ 95% AFUE BE ENAMELED METAL WITH V-CRIMP TYPICAL. ROOF-TO-MASONRY CONDITIONS SHALL HAVE ENAMELED STEPFLASH AND COUNTERFLASH. All components of heating system to be installed within heated space, and no such components may be installed in crawlspace. EXTERIOR DOORS: ALL EXTERIOR DOORS SHALL BE SELECTED BY OWNER. COLOR TO BE DETERMINED. PROVIDE CONTINUOUS INTERLOCKING METAL WEATHER-STRIPPING, ANODIZED METAL THRESHOLD, CYLINDER ENTRY LOCK ACCESS AND DEADBOLT DRILLING. DOUBLE-GLAZED SAFETY GLASS, WITH LOW-E (COLOR TO MATCH WINDOWS), AS INDICATED ON DRAWINGS. U-VALUE OF DOORS TO BE 0.30 OR BETTER; DOORS WITH MORE THAN 50% GLAZING TO HAVE A U-VALUE OF 0.30 OR BETTER. PROVIDE SCREENS AT SLIDING DOORS ONLY WHEN INDICATED ON DRAWINGS. PROVIDE LOEWEN, SIERRA PACIFIC, WEATHERSHIELD OR EQUAL AS APPROVED BY OWNER. MEDICI ARCHITECTS Issue Date INTAKE DATE: DATE: REVISIONS: 1. 2. 3. 4. 5. REVISION 1 2-11-2015 REVISION 2 3-10-2015 PROJECT / CLIENT: TERRI BELLA RESIDENCES LOT 9 335 PARKPLACE CENTER G119 KIRKLAND, WA 98033 JOB ADDRESS: 328 4TH AVE S KIRKLAND, WA 98033 *HIGHLY VISIBLE SIGNS SPACED NO FURTHER THAN 15 FEET SHALL BE PLACED ALONG SIDES OF THE TPZ FENCING. EAST UNIT DRAWING NAME: *ASSESS CREW AND CONTRACTOR PENALTIES, IF NECESSARY, TO KEEP THE TPZ'S INTACT. WATER HEATER INSTALL NEW 0.82 EF GAS TANKLESS WH. Noritz Model NR66 Series or Equal *CHECK THE INTEGRITY OF TPZ FENCES WEEKLY, AND REPAIR OR REPLACE AS NEEDED. GARAGE/ CARPORT DUCTS: DUCTS IN THE GARAGE/CARPORT AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE/CARPORT MUST BE A MINIMUM OF 26 GAUGE SHEET METAL WITH NO REGISTER OUTLETS INTO THE GARAGE. DUCTS OUTSIDE THE PROTECTED ENVELOPE ARE EXCLUDED FROM THESE REGULATIONS. *WOOD CHIPS SHOULD BE USED IF POSSIBLE TO SPREAD ABOVE ROOT ZONES WITHIN THE TPZ'S TO A DEPTH OF 6-8 INCHES FOR TEMPORARY PROTECTION. EXHAUST FANS: PROVIDE EXHAUST FANS WHERE SHOWN ON FLOOR PLANS A2.0 & A2.1. *AVOID GRADE CHANGES OR TRENCHING WITHIN OR NEAR THE TPZ. IF IT IS UNAVOIDABLE, THEN FOLLOW THE GUIDELINES BELOW. THERMOSTAT(S): PROVIDED BY MECHANICAL CONTRACTOR; VERIFY LOCATION(S) W/OWNER. *TPZ'S MAY ONLY BE MOVED OR ACCESSED WITH PERMISSION FROM CITY OFFICIALS, AND ANY WORK DONE WITHIN TPZ'S MUST BE DONE WITH A CERTIFIED ARBORIST PRESENT. GAS APPLIANCE FIREPLACES: HEAT AND GLO - RED 60 OR SIMILAR - VERIFY W/OWNER. PLUMBING: ALL PLUMBING TO BE INSTALLED PER THE UPC. WATER HEATERS IN UNCONDITIONED SPACE SHALL HAVE A THERMAL RESISTANCE OF R-10 FOR THE HEATER BASE PER R403.4.3 (WSEC WAC 51-11). PROVIDE SEISMIC STRAPS PER THE UPC. DRAIN HOT WATER TANK PRESSURE-RELIEF VALVE TO OUTSIDE OF BUILDING OR TO FLOOR DRAIN (PROVIDE 1" MINIMUM AIR GAP) USING HARD-DRAWN COPPER PIPING. PROVIDE RETICULATING PUMP AND PLUMB FOR INSTANT HOT WATER. SOURCES OF IGNITION MUST BE KEPT AT LEAST 18" ABOVE FLOOR LINE. PROVIDE PLUMBING TO ALL FIXTURES SHOWN ON DRAWINGS. PROVIDE INSULATION FOAM AT ALL FLOOR, ROOF, AND WALL PLUMBING PENETRATIONS. TO ACHIEVE WSEC CREDIT OPTION 5B PER TABLE 406.2 ALL SHOWERHEAD AND KITCHEN SINK FAUCETS SHALL HAVE MAXIMUM FLOW OF 1.75 GPM. ALL OTHER LAVATORY FAUCETS SHALL BE RATED AT 1.0 GPM OR LESS. SPRINKLER SYSTEM: FOR DUPLEX - AUTOMATIC SPRINKLERS ARE REQUIRED PER NFPA 13D AND CITY OF MUKILTEO FIRE DEPARTMENT STANDARDS. PROVIDE A 1" MIN. METER CONNECTION. SPRINKLER SYSTEM TO PROVIDE COVERAGE THROUGHOUT STRUCTURE, INCLUDING DECKS AND GARAGE. DESIGNED BY A WASHINGTON STATE CERTIFIED ENGINEER. CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF INTERNATIONAL FIRE CODE CHAPTER 14. THE SYSTEM SHALL BE INSTALLED, INSPECTED, TESTED, AND APPROVED PRIOR TO FRAMING INSPECTION APPROVAL. A SEPARATE PERMIT MAY BE REQUIRED. ALL SPRINKLER HEADS SHALL BE RECESSED. COORDINATE LOCATIONS WITH LIGHTING PLAN, TYPICAL. VERIFY WITH GENERAL CONTRACTOR & ARCHITECT. DIVISION 16 - ELECTRICAL: *CEMENT TRUCKS MUST NOT DEPOSIT WASTE OR RINSE OUT TRUCKS IN THE TPZ. *IF ROOTS NEED TO PRUNED, THEY SHOULD BE CUT WITH PRUNING SAWS, MADE FLUSH WITH THE SIDE OF THE TRENCH. *TREES SHOULD BE WATERED TWICE A WEEK IF CONSTRUCTION IS TO TAKE PLACE DURING HOT SUMMER MONTHS. IF EXCAVATION OCCURS WITHIN THE DRIPLINES OF TREES SCHEDULED FOR RETENTION, THE FOLLOWING PROCEDURES MUST BE FOLLOWED TO PROTECT THEM: *THE CONTRACTOR SHALL VERIFY THE VERTICAL AND HORIZONTAL LOCATION OF EXISTING UTILITIES TO AVOID CONFLICTS AND MAINTAIN MINIMUM CLEARANCES; ADJUSTMENT SHALL BE MADE TO THE GRADE OF THE NEW UTILITY AS REQUIRED. *THE INNER ROOT ZONE SHALL NOT BE DISTURBED OR CUT (INNER ROOT ZONE = HALF THE DRIP LINE RADIUS). GENERAL NOTES Drawn By: US Checked By: EB Owner Approval: PHASE: PERMIT SET This drawing is the exclusive property of medici architects, and can be reproduced only with the permission of the architect. variations and modifications to work shown on this drawing shall not be carried out without written permission from the architect. APPROVED FOR CONSTRUCTION: *ISA CERTIFIED ARBORIST MUST WORK WITH EQUIPMENT OPERATORS DURING TRENCHING/ EXCAVATION. THE ARBORIST SHOULD HAVE A SHOVEL, HAND PRUNERS, LOPPERS, HANDSAW, AND A SAWSALL. *IF ROOTS ONE INCH OR LARGER ARE DAMAGED BY EQUIPMENT, THE ARBORIST SHALL STOP THE EQUIPMENT AND HAVE THE DIRT EXCAVATED BY HAND UNTIL THE ROOT CAN BE CLEANLY CUT. A CLEAN STRAIGHT CUT SHALL BE MADE TO REMOVE THE DAMAGED PORTION OF ROOT, AND IF POSSIBLE THE ROOTS SHOULD BE COVERED IN MOIST BURLAP UNTIL RECOVERED WITH DIRT THE SAME DAY. *BORING OR TUNNELING UNDER ROOTS OF EXISTING TREES IS A VIABLE ALTERNATIVE TO TRENCHING THROUGH ROOTS. IT SHALL BE PERFORMED UNDER THE SUPERVISION OF AN ISA CERTIFIED ARBORIST, AND NO ROOTS 1 INCH IN DIAMETER OR LARGER SHALL BE CUT. SKYLIGHTS: NOT USED. ALL WORK SHALL CONFORM TO CURRENT AND APPLICABLE CODES AND SHALL BE COORDINATED WITH THE GENERAL CONTRACTOR. ELECTRICAL CONTRACTOR SHALL VERIFY REQUIREMENTS TO WIRE AND HOOK UP ALL EXHAUST FANS, APPLIANCES, FURNACES, AIR CONDITIONERS AND ALL OTHER EQUIPMENT REQUIRING ELECTRICAL SERVICE. ELECTRICAL CONTRACTOR SHALL VERIFY AND ACQUIRE APPROVAL OF PANEL DISTRIBUTION AND SERVICE FROM OWNER AND GENERAL CONTRACTOR PRIOR TO INSTALLATION. INSULATION FOAM: PROVIDE INSULATION FOAM AT ALL FLOOR, ROOF, AND WALL ELECTRICAL PENETRATIONS. *THE GRADE SHALL NOT BE ELEVATED OR REDUCED WITHIN THE CRITICAL ROOT ZONE OF TREES TO BE PRESERVED WITHOUT THE PLANNING OFFICIAL'S AUTHORIZATION BASED ON RECOMMENDATIONS FROM A QUALIFIED PROFESSIONAL. THE PLANNING OFFICIAL MAY ALLOW COVERAGE OF UP TO ONE HALF OF THE AREA OF THE TREE'S CRITICAL ROOT ZONE WITH LIGHT SOILS (NO CLAY) TO THE MINIMUM DEPTH NECESSARY TO CARRY OUT GRADING OR LANDSCAPING PLANS, IF IT WILL NOT IMPERIL THE SURVIVAL OF THE TREE. AERATION DEVICES MAY BE REQUIRED TO ENSURE THE TREE'S SURVIVAL. PROJECT No.: 2014052 DATE/ TIME: 3/10/2015 2:30:40 PM A0.1 LIGHTING FIXTURE LAMPS: PROVIDE AND INSTALL GE OR SYLVANIA LAMPS. ALL INCANDESCENT LAMPS RECESSED INTO INSULATED AREAS SHALL BE APPROVED FOR ZERO-CLEARANCE INSULATION COVER. ALL FLUORESCENT LAMPS SHALL BE FULL-SPECTRUM. PLOT SCALE: 1:1 EXTERIOR WINDOW TYPES WINDOW SCHEDULE E 2'-0" F Egress 6.72 sf Egress 10.86 sf EGRESS AT 3RD FLOOR SG SG 4" MAX. OPENING AT OPERABLE SECTIONS OF WINDOWS 5'-0" 3'-0" 3'-0" 3'-0" 5'-0" 2'-0" 2'-0" 2'-0" 3'-0" SG K 3' - 0" 5' - 0" 2' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 3' - 0" 5' - 0" 5' - 0" 5' - 0" 2' - 0" 5' - 0" 5' - 0" 3' - 0" 5' - 0" 5' - 0" 4' - 3" 5' - 0" 5' - 8" 5' - 6" 4' - 0" 4' - 0" 4' - 0" 5' - 8" 5' - 8" 7' - 0" 7' - 0" 7' - 0" 1' - 8" 5' - 0" 5' - 0" 5' - 0" 1' - 8" 4' - 2" 7' - 0" 4' - 2" 4' - 2" SG SG MAX. 4" OPENING AT OPERABLE SECTIONS OF WINDOWS SG No 4" MAX. OPENING AT OPERABLE SECTIONS OF WINDOWS 1 2 3 4 5'-0" 5'-0" 3'-0" 2'-2" 2'-0" 5'-0" M 5'-0" 5'-0" O N P 4'-2" 2'-10" 1'-8" 3'-0" 2'-6" 2'-0" 2'-0" 0.3 Qty 3 1 2 1 Door Location Width ENTRY/BONUS RM./3RD FLR. DECK GARAGE GARAGE/ MECH. RM. 2ND FLR. DECK 3' - 0" Height 7' - 0" 16' - 0" 2' - 10" 6' - 0" 7' - 3" 7' - 0" 8' - 0" Area 63 SF 116 SF 40 SF 48 SF Screen FIXED/AWNING FIXED/ AWNING CASEMENT FIXED/CASEMENT FIXED/CASEMENT FIXED/ CASEMENT FIXED/ CASEMENT FIXED/AWNING FIXED/AWNING FIXED/ AWNING FIXED/ AWNING CASEMENT FIXED/ CASEMENT FIXED/ CASEMENT AWNING FIXED/ CASEMENT FIXED FIXED FIXED/ CASEMENT Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y N N Y Hardware TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD Comments Architecture Programming Accessible Design Interior Design SAFETY GLASS SAFETY GLASS EGRESS SAFETY GLASS, EGRESS SAFETY GLASS SAFETY GLASS SAFETY GLASS SAFETY GLASS SAFETY GLASS AT STAIR EGRESS SAFETY GLASS AT STAIR UXA= 236.4 City of Kirkland Reviewed by R Braun 03/11/2015 11661 SE1st Street, Suite 200 Bellevue, Washington 98005 Tel: (425) 453-9298 Fax: (425) 452-8448 NOTE: SEE A0.2 & A4.0-A4.1 FOR WINDOW DIVISIONS. REGISTRATION: Manufacturer TBD TBD TBD TBD U-Value 0.3 0.3 0.3 0.3 Door Type FULL GLASS PANEL DOOR Configuration REGISTERED ARCHITECT X OVERHEAD GARAGE DOOR X SOLID FLUSH DOOR X 2 PANEL SLIDING GLASS DOOR X Comments EMILY D. BUCHWALTER ALL GLAZING FOR DOORS, TRANSOM AND SIDELITES TO BE SAFETY GLASS GARAGE DOOR OPENER, SEE ELEVATIONS FOR DOOR PATTERN 20 MIN. FIRE RATED W/SELF CLOSER/INSULATED ALL GLAZING FOR DOORS, TRANSOM AND SIDELITES TO BE SAFETY GLASS STATE OF WASHINGTON Issue Date INTAKE DATE: Total Exterior Door Area (A): 267 SF - 116 SF(GARAGE) = 151 SF 0.3 U X A = 45.3 Notes: 1. GENERAL CONTRACTOR SHALL PROVIDE MANUFACTURER'S DATA ON ALL WINDOWS SHOWING COMPLIANCE WITH THE 2012 WASHINGTON STATE ENERGY CODE. 2. ALL EXTERIOR TRUE DIVIDED FIXED TRANSOM GLAZING TO BE POSITIONED AT UPPER SASH. 3. VERIFY ALL DOOR TYPES & HARDWARE W/OWNER PRIOR TO ORDERING. 4. DOOR SEPARATING UN-HEATED FROM HEATED SPACE TO BE U=0.30 MAX PER WSEC 2012. 5. ALL DOOR WITH GLAZING TO BE NFRC CERTIFIED AND LABELED. 6. ALL HARDWARE TO BE BRUSHED NICKLE FINISH 2-PAIR BUTT HINGES. CONFIRM WITH OWNER. DATE: REVISIONS: 1. 2. 3. 4. 5. REVISION 1 2-11-2015 REVISION 2 3-10-2015 INTERIOR DOOR SCHEDULE No 5'-0" 4'-3" 3'-0" 2'-0" 7'-0" 4'-2" Door Location Width 2' - 6" 5' - 0" 2' - 10" 5' - 0" 2' - 0" 3' - 0" Height 7' - 0" 6' - 8" 7' - 0" 7' - 0" 7' - 0" 7' - 0" Manufacturer TBD TBD TBD TBD TBD TBD Door Type SLIDING CLOSET DOOR SOLID SWINGING DOUBLE SOLID SWINGING SOLID SWINGING SURFACE SLIDER Notes: 1. GENERAL CONTRACTOR SHALL PROVIDE MANUFACTURER'S DATA ON ALL WINDOWS SHOWING COMPLIANCE WITH THE 2012 WASHINGTON STATE ENERGY CODE. 2. ALL EXTERIOR TRUE DIVIDED FIXED TRANSOM GLAZING TO BE POSITIONED AT UPPER SASH. 3. VERIFY ALL DOOR TYPES & HARDWARE W/OWNER PRIOR TO ORDERING. 4. DOOR SEPARATING UN-HEATED FROM HEATED SPACE TO BE U=0.30 MAX PER WSEC 2012. 5. ALL HARDWARE TO BE BRUSHED NICKLE FINISH 1 1/2-PAIR BUTT HINGES. CONFIRM WITH OWNER. S R 4'-2" 1'-8" 3'-0" Qty 5 17 6 1 1ST FLR. GUEST ROOM 7 1 LAUNDRY 8 1 MASTER BEDROOM 9 1 3RD FLR. HALLWAY CLOSET 10 1 MASTER BATH Interior Door Total: 22 5'-0" 5'-4" 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 Window Type 267 SF Egress 8.56 sf SG NOTE: SAFETY GLASS: SG DIMENSIONS INDICATE ROUGH OPENINGS SEE NOTES FOR WINDOW FALL PROTECTION OPERABLE SECTIONS OF WINDOWS SHALL NOT PERMIT OPENINGS THAT ALLOW PASSAGE OF A 4-INCH-DIAMETER(102mm) SPHERE WHERE SUCH OPENINGS ARE LOCATED WITHIN 24 INCHES (610mm) OF THE FINISHED FLOOR, TYP. PER IRC R312.2 Comments PROJECT / CLIENT: TERRI BELLA RESIDENCES LOT 9 335 PARKPLACE CENTER G119 KIRKLAND, WA 98033 JOB ADDRESS: 328 4TH AVE S KIRKLAND, WA 98033 EAST UNIT DRAWING NAME: SCHEDULES Drawn By: US Checked By: EB Owner Approval: EXTERIOR DOOR TYPES 3'-0" 2'-10" PHASE: 6'-0" 16'-0" PERMIT SET 2 This drawing is the exclusive property of medici architects, and can be reproduced only with the permission of the architect. variations and modifications to work shown on this drawing shall not be carried out without written permission from the architect. 4 3 1 7'-0" 7'-0" SG 8'-0" SG 7'-0" TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD U-Value 1. GENERAL CONTRACTOR SHALL PROVIDE MANUFACTURER'S DATA ON ALL WINDOWS SHOWING COMPLIANCE WITH THE 2012 WASHINGTON STATE ENERGY CODE. 2. ALL EXTERIOR TRUE DIVIDED FIXED TRANSOM GLAZING TO BE POSITIONED AT UPPER SASH. 3. ALL WINDOWS TO BE NFRC CERTIFIED AND LABELED. 1'-8" SG 1'-8" 1'-8" SG 5'-0" SG 85 SF 28 SF 32 SF 40 SF 20 SF 28 SF 57 SF 147 SF 35 SF 35 SF 17 SF 60 SF 25 SF 75 SF 10 SF 21 SF 35 SF 18 SF 21 SF 788 SF Total Window Area: 788 SF Notes: Exterior Door Total: 7 Q Manufacturer 6926 MAX. 4" OPENING AT OPERABLE SECTIONS OF WINDOWS 2'-0" Area EXTERIOR DOOR SCHEDULE EGRESS AT 3RD FLOOR L Height J 1'-6" SG Width 7'-0" 5'-4" 5'-4" 7'-0" H 7'-0" 5'-8" Egress 10.86 sf SG 5'-4" I 4'-2" G Window Location 3'-0" 1'-8" 2'-0" 5'-0" 5'-0" Qty A 5 ENTRY/ MASTER BEDROOM B 1 MUD ROOM C 4 BONUS ROOM/ BEDROOM 3 D 2 BONUS ROOM/ BEDROOM 3 E 1 BONUS ROOM F 1 1ST FLR. GUEST ROOM G 2 GUEST RM./ BEDROOM 2 H 7 LIVING ROOM I 1 DINING ROOM J 1 STAIRS K 2 STAIRS/ BEDROOM 2/ MASTER BATHRM L 6 VARIOUS M 1 AWAY ROOM N 3 AWAY ROOM/ KITCHEN O 2 MASTER CLOSET/ BATHROOM #3 P 1 LAUNDRY Q 1 STAIRS R 1 MASTER BATHROOM S 1 STAIRS/ BEDROOM 2/ MASTER BATHRM Window Count: 43 5'-8" D 3'-0" 2'-2" 4'-0" 2'-10" No 1'-8" SG 3'-0" 4'-0" 5'-6" C 1'-8" SG 2'-0" 2'-0" B 1'-8" SG 2'-0" 3'-10" 5'-8" 4'-0" 3'-0" 4'-0" 3'-0" 5'-0" 5'-0" 4'-0" 5'-0" 5'-0" A MEDICI ARCHITECTS APPROVED FOR CONSTRUCTION: FINISHED FLOOR PROJECT No.: 2014052 DATE/ TIME: 3/10/2015 2:30:42 PM A0.2 PLOT SCALE: 1:1 40'-0" MEDICI ARCHITECTS PROPERTY LINE 3 1 A 4 6 2 Architecture Programming Accessible Design Interior Design 5 A5.0 5'-0" 30'-0" 5'-0" 10'-10" SIDE SETBACK FLOOR PLAN NOTES SIDE SETBACK 8'-0" 3'-4" 9'-7" 9 1/2" 8'-3 1/2" 1. PROPERTY LINE 30'-0" 11'-4" 2. 3. 4. 5. 6. 7. 18'-8" 4 A6.0 A 4'-8 1/2" 3'-0" PATIO CONCRETE SLAB SLOPE 1/4" PER 12" 9. 10. TYP. 16" X 8" CRAWL SPACE VENTS PROVIDE VENT WELLS AS NEEDED TO ENSURE AIR FLOW. (TYP.) B 11. 13'-11" 4'-8 1/2" 8. 9'-2 1/2" 8" FOUNDATION WALL PER STRUCTURAL PLANS 3 11661 SE1st Street, Suite 200 Bellevue, Washington 98005 Tel: (425) 453-9298 Fax: (425) 452-8448 SYMBOL LEGEND HOLDDOWN LOCATION PER STRUCTURE PLANS ENSURE VENTS ARE NOT AT HOLDOWN LOCATIONS (TYP.) REGISTERED ARCHITECT 6926 FOUNDATION WALL MIN. 18" CLEAR SPACE BELOW JOIST 20'-0" City of Kirkland Reviewed by R Braun 03/11/2015 REGISTRATION: CRAWL SPACE 727 SF R-30 INSULATION IN FLOOR SYSTEM, CLASS 1 VAPOR RETARDER OVER GRADE AND UP STEM WALLS, MIN. 6 MIL. A6.0 C 12. CONTRACTOR SHALL VERIFY ALL NOTES, DIMENSIONS & CONDITIONS PRIOR TO CONSTRUCTION. ALL POSTS, BEAMS & HEADERS SEE STRUCTURAL DRAWINGS PROVIDE SOLID BLOCKING OVER SUPPORTS. PROVIDE FIRE BLOCKING @ ALL PLUMBING PENETRATIONS. WINDOWS & DOORS ARE SHOWN & NOTED AS NOMINAL SIZES. DOOR JAMB 4.5" U.N.O. SEE SHEETS A0.2, A4.0 & A4.1 FOR WINDOW & DOOR HEADER HEIGHTS ABOVE FINISHED FLOOR. ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE TREATED. EXTERIOR WALLS TO BE 2x6 STUDS @ 16" O.C., U.N.O. INSTALL SIMPSON CONC. TO WOOD HOLDOWNS PER STRUCTURAL DRAWINGS, ALSO SEE MANUFACTURER'S SPECS. SMOKE & CARBON MONOXIDE DETECTORS: *SHALL BE 110V INTERCONNECTED W/ BATTERY BACKUP. *SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING ROOMS. *SHALL BE INSTALLED ON EACH FLOOR AND IN ALL BEDROOMS. *SHALL BE INSTALLED IN EACH LOCATION WHERE THERE IS A CEILING CHANGE OF GREATER THAN 24" SEE SHEET A0.1 & A0.2 FOR ADDITIONAL NOTES. EMILY D. BUCHWALTER 5 1/2" STATE OF WASHINGTON 6'-8" 6'-8" SLAB ON GRADE 7'-2 3/4" FIRST FLOOR SYSTEM TO BE HUNG ON FOUNDATION WALL (TYP.) SEE STRUCTURAL DRAWINGS POST - VERIFY SIZE AND TYPE WITH STRUCTURAL PLAN 5 1/2" CRAWL SPACE VENTILATION 6'-11 1/2" 80'-0" 5'-9 1/2" 12'-7 1/2" Crawl Space Area = Ventilation Required: Use: 727.00 s.f. 727.00 s.f. x 144/1500 = 69.8s.i. Req'd Vent Area = Vents Required = Provide: 16"X8" Foundation Vents 69.8 s.i. / vent area 9.00 / 16”x8” Vents, 50.00 s.i. 1.39 vents Area = 300.00 s.i. Total Min. Ventilation Provided = 300.00 s.i. IS GREATER THAN 4" CONCRETE SLAB ON GRADE EXPANSION JOINTS IN CONCRETE FLOOR 1'-5 1/2"2'-3 1/2" H I A6.0 8'-2" G 5 69.8 s.i. Req'd * NOTE: Per SRC R408.1...When a Class 1 vapor retarder material is used, the minimum net area of ventilation openings shall not be less than 1 square foot (0.0929 m2) for each 1,500 square feet (140 m2) of under-floor space area. 9 1/4" LINE OF FOOTINGS 20'-8" 4'-5" F DATE: REVISIONS: 9'-11" 6" E Issue Date INTAKE DATE: 45'-4 1/2" 4'-1 1/2" 45'-4 1/2" D R-30 INSULATED CRAWL SPACE ACCESS DOOR ABOVE MIN. 18"x24" THROUGH THE FLOOR PER IRC 408.4 LINE OF BUILDING SETBACK 1. 2. 3. 4. 5. REVISION 1 2-11-2015 REVISION 2 3-10-2015 PROJECT / CLIENT: TERRI BELLA RESIDENCES LOT 9 335 PARKPLACE CENTER G119 KIRKLAND, WA 98033 JOB ADDRESS: CONCRETE SLAB PER STRUCTURAL PLANS SLOPE 3" TO FRONT OF THE GARAGE 328 4TH AVE S KIRKLAND, WA 98033 6'-8 1/2" 6'-8 1/2" EAST UNIT CONCRETE SLAB PER STRUCTURAL PLANS MIN.1/4" PER 12" DRAWING NAME: FOUNDATION PLAN 104'-1" J FRONT GARAGE Drawn By: OTR/US Checked By: EB Owner Approval: START OF CONSTRUCTION PHASE: 2 NOTES: 1- REFER TO STRUCTURAL PLANS FOR ALL FRAMING & FOUNDATION INFORMATION A6.0 23'-9 1/2" 20'-11" 5'-0" 2- ALL IMPERVIOUS SURFACES TO BE GRADED TO SLOPE AND DRAIN AWAY FROM THE STRUCTURE MIN. 1/4" PER 12" 8'-3 3/4" PERMIT SET This drawing is the exclusive property of medici architects, and can be reproduced only with the permission of the architect. variations and modifications to work shown on this drawing shall not be carried out without written permission from the architect. 30'-0" APPROVED FOR CONSTRUCTION: 1'-6" DRIVEWAY 4" CONCRETE SLAB 14.9% SLOPE 18'-0" 5'-9 1/4" 4'-0" 5'-9 1/4" PROPERTY LINE PROJECT No.: 2014052 40'-0" DATE/ TIME: 3/10/2015 2:30:43 PM PROPERTY LINE 1 A1.0 FOUNDATION PLAN 1/4" = 1'-0" PLOT SCALE: 1:1 40'-0" MEDICI ARCHITECTS PROPERTY LINE 1 2 A 3 4 5 6 A5.0 SIDE SETBACK 8'-0" REAR SETBACK 3'-4" 5'-0" SIDE SETBACK 9'-7" 9 1/2" 11'-4" 8'-3 1/2" 18'-8" 3'-2" 5'-0" 3'-2" 2'-3" 5'-0" 4'-5 1/2" 5'-0" 9" A6.2 5'-0" CL 2'-6" 2'-10" 2 C 10" 2'-6 1/2" 2'-3 1/2" 5 5 6'-1 1/2" 5 STORAGE UNDER STAIRS 5 1/2" SG J 8 3'-6" 5 3'-6" CO CLR. 3'-9 1/2" 6'-8" SD 14 RISE @ 7 1/4" UP 12" ACTUAL RUN 3'-6" BATHROOM 1 1'-6" 3 107.27' 2'-10" 3'-6" B MUD ROOM 2 A6.3 4'-8" 3'-2 1/4" SD SMOKE DETECTOR CO CARBON MONOXIDE DETECTOR NOTE: GUARDS ON THE OPEN SIDES OF STAIRS SHALL NOT HAVE OPENING WHICH ALLOWS PASSAGE OF A SPHERE 4 3/8" IN DIAMETER. 1 DOORS 20'-0" CLR. A6.2 2'-3 1/2" GARAGE A WINDOWS CONCRETE SLAB PER STRUCTURAL PLANS MIN.1/4" PER 12" 6'-8 1/2" 10" A6.0 2'-5 1/2" 4" CONCRETE DRIVEWAY SLOPE 14.9% 2'-5 1/2" HOUSE VENTILATION JOB ADDRESS: 2012 IRC - PROVIDE WHOLE HOUSE VENTILATION PER M1507, INTERMITTENT WHOLE HOUSE VENTILATION USING EXHAUST FAN PER 1507.3 TABLE1507.3.3(1) & TABLE1507.3.3(2), PROVIDE CONTROLS PER 1503.2. COMPLY WITH WSEC R403.5. 328 4TH AVE S KIRKLAND, WA 98033 LOCATION MINIMUM FAN REQUIREMENTS Bath & Powder Min. 50 cfm (INTERMITTENT) @ .025" WG (TABLE M1507.3) B Kitchen Min. 100 cfm (INTERMITTENT)@ .025" WG (TABLE M1507.3) (Range hood or down draft exhaust fan rated at min. 100 cfm at 0.10" wg may be used for exhaust fan requirement.) C Laundry Room Min. 180cfm (INTERMITTENT) @ .025" WG - to function and be labeled as whole house fan (4-5 BEDROOMS 3001< 4500 SF.) TO OPERATE 50% OF EVERY FOUR HOUR PERIOD A 4'-0" 5'-9 1/4" 1'-6" 23'-9 1/2" 9'-1" 5'-9 1/4" DRYER VENT PER (TABLE M1502.4.4.1) VENTED TO OUTSIDE *ALL FANS TO VENT TO OUTSIDE ALL SHOWERHEAD AND KITCHEN SINK FAUCETS SHALL BE RATED @ 1.75 GPM OR LESS. ALL OTHER LAVATORY FAUCETS SHALL BE RATED @ 1.0 GPM OR LESS. CONTRACTOR TO KEEP PRODUCT LITERATURE ON SITE. 8'-1" 20'-11" 18'-0" 3-10-2015 EAST UNIT DRAWING NAME: LINE OF EDGE OF DECK ABOVE 16'-0" REVISION 2 PROJECT / CLIENT: 8" A6.4 2-11-2015 POST - VERIFY SIZE AND TYPE WITH STRUCTURAL PLAN SYMBOL POST PER STRUCTURAL 107.06 8" 9 REVISION 1 LINE OF BUILDING ABOVE 6'-0 1/2" 3'-0" 5'-8 1/4" 1'-5 1/2" 1'-2 3/4" A 3" 3'-0" 2% SLOPE TRENCH DRAIN TIGHTLINE AS PROPOSED PER CIVIL PLANS 1. 2. 3. 4. 5. TERRI BELLA RESIDENCES LOT 9 START OF CONSTRUCTION CONTROL JOINT AT CONCRETE SLAB @ 10' MAX. SPACING, TYP. FOUNDATION WALL & FOOTING DATE: REVISIONS: A6.3 CONCRETE SLAB PER STRUCTURAL PLANS SLOPE 3" TO FRONT OF THE GARAGE 2 Issue Date INTAKE DATE: 2X WALLS R-30 INSULATED CRAWL SPACE ACCESS DOOR MIN. 18"x24" THROUGH THE FLOOR PER IRC 408.4 1 J EMILY D. BUCHWALTER 335 PARKPLACE CENTER G119 KIRKLAND, WA 98033 8 2 CAR GARAGE CEILING HEIGHT: 8'-0" 2 REGISTERED ARCHITECT STATE OF WASHINGTON IRC R312.1.3 (1) THE TRIANGULAR OPENINGS AT THE OPEN SIDES OF A STAIR, FORMED BY THE RISER,TREAD AND BOTTOM RAIL OF A GUARD, SHALL NOT ALLOW PASSAGE OF A SPHERE 6" IN DIAMETER. IRC R312.1.3 (2) GUARDS ON THE OPEN SIDES OF STAIRS SHALL NOT HAVE OPENING WHICH ALLOWS PASSAGE OF A SPHERE 4 3/8" IN DIAMETER. 3'-11" LINE OF BUILDING ABOVE 1 6'-8 1/2" I ENTRY 11661 SE1st Street, Suite 200 Bellevue, Washington 98005 Tel: (425) 453-9298 Fax: (425) 452-8448 SYMBOL LEGEND NOTE: PER IRC 301.5 GUARDS AND HANDRAILS SHALL BE ABLE TO RESIST A SINGLE CONCENTRATED LOAD OF 200 LBS/SF APPLIED IN ANY DIRECTION AT ANY POINT ALONG THE TOP AND TO TRANSFER THIS LOAD THROUGH THE SUPPORTS TO THE STRUCTURE. PER IRC 301.5 9 1/4" A6.3 City of Kirkland Reviewed by R Braun 03/11/2015 6926 10'-3 3/4" 4'-5" 2 Architecture Programming Accessible Design Interior Design REGISTRATION: PROVIDE ILLUMINATION PER IRC R303.6 18'-1" CLR. 1'-8" 20'-0" F H R303.7 STAIRWAY ILLUMINATION ALL INTERIOR STAIRWAYS SHALL BE PROVIDED WITH A MEANS TO ILLUMINATE THE STAIRS, INCLUDING THE LANDINGS AND TREADS. STAIRWAY ILLUMINATION SHALL RECEIVE PRIMARY POWER FROM THE BUILDING WIRING. INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED IN THE IMMEDIATE VICINITY OF EACH LANDING OR THE STAIRWAY. FOR INTERIOR STAIRS THE ARTIFICIAL LIGHT SOURCE SHALL BE CAPABLE OF ILLUMINATING TREADS AND LANDINGS TO LEVELS NO LESS THAN 1 FOOT-CANDLE MEASURED AT THE CENTER TREADS AND LANDINGS. SLAB ON GRADE 13'-5 1/2" 80'-0" 1'-0" 5'-0 1/2" 8'-5 1/2" 30'-10 1/2" ON DEMAND WATER HEATER MIN. EF= 0.82, VENTED TO OUTSIDE 2'-10" 5 6" 107.27 40'-8" 9'-11" 3 5'-0" 3'-2" A ALIGN WH 2'-7" 46'-2 1/2" D CONTRACTOR SHALL VERIFY ALL NOTES, DIMENSIONS & CONDITIONS PRIOR TO CONSTRUCTION. ALL POSTS, BEAMS & HEADERS SEE STRUCTURAL DRAWINGS PROVIDE SOLID BLOCKING OVER SUPPORTS. PROVIDE FIRE BLOCKING @ ALL PLUMBING PENETRATIONS. WINDOWS & DOORS ARE SHOWN & NOTED AS NOMINAL SIZES. DOOR JAMB 4.5" U.N.O. SEE SHEETS A0.2, A4.0 & A4.1 FOR WINDOW & DOOR HEADER HEIGHTS ABOVE FINISHED FLOOR. ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE TREATED. EXTERIOR WALLS TO BE 2x6 STUDS @ 16" O.C., U.N.O. INSTALL SIMPSON CONC. TO WOOD HOLDOWNS PER STRUCTURAL DRAWINGS, ALSO SEE MANUFACTURER'S SPECS. SMOKE & CARBON MONOXIDE DETECTORS: *SHALL BE 110V INTERCONNECTED W/ BATTERY BACKUP. *SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING ROOMS. *SHALL BE INSTALLED ON EACH FLOOR AND IN ALL BEDROOMS. *SHALL BE INSTALLED IN EACH LOCATION WHERE THERE IS A CEILING CHANGE OF GREATER THAN 24" SEE SHEET A0.1 & A0.2 FOR ADDITIONAL NOTES. A6.3 45'-4 1/2" 1'-10" 5'-0" 5'-2" 4 A6.4 2'-9 1/4" 10" 5'-9 1/2" A6.2 3'-6" SD 6'-8" GUEST ROOM FURN G 2'-0" 6'-7 1/2" 9'-9 1/2" G 8" 5'-0" A6.1 12. 13'-11" 6 3 A6.3 13'-3 1/2" 8" BONUS ROOM 3 E 11. 1'-9 1/2" A6.1 C 9. 10. 2 Egress 10.86 sf 2 A6.2 95.1% AFUE FURNACE TO BE DIRECT VENTED TO OUTSIDE. COMBUSTION AIR & FRESH AIR TO BE PROVIDED THROUGH WALL. ALL COMPONENTS INSTALLED INSIDE THE CONDITIONED SPACE. 55,160 Btu/hr. MAXIMUM C 1 1 2. 3. 4. 5. 6. 7. 8. F 4'-1 1/2" 9'-2 1/2" TYPICAL@ALL WINDOWS D 2'-0" 3'-0" PATIO CONCRETE SLAB SLOPE 1/4" PER 12" 6" 4'-8 1/2" 4'-8 1/2" B 6" SQUARE DOWNSPOUT 1'-11 1/2" 1'-2 1/2" E A FLOOR PLAN NOTES 1. LINE OF CANOPY ABOVE 3'-6" 10'-0" PROPERTY LINE 30'-0" 10'-10" 5'-0" CONCRETE WALKWAY 1ST FLOOR PLAN Drawn By: US Checked By: EB Owner Approval: PHASE: PERMIT SET This drawing is the exclusive property of medici architects, and can be reproduced only with the permission of the architect. variations and modifications to work shown on this drawing shall not be carried out without written permission from the architect. 14.9% APPROVED FOR CONSTRUCTION: 14.9% PROPERTY LINE PROPERTY LINE PROJECT No.: 2014052 DATE/ TIME: 1 3/10/2015 2:30:43 PM A2.0 1ST FLOOR PLAN 1/4" = 1'-0" PLOT SCALE: 1:1 MEDICI ARCHITECTS 40'-0" 1 3 A 4 6 A5.0 FLOOR PLAN NOTES 5'-0" 30'-0" 11'-4" 9'-7" 11'-4" 9'-1" 3'-2" 2'-3" 5'-0" 4'-5 1/2" 5'-0" 7 A6.4 5'-5 1/4" 1'-0" 2'-0" 1'-8 1/2" 4'-5" 11. 3'-3" D K UP 16 RISE @ 7 1/4" 12" ACTUAL RUN 11'-1 1/2" 11'-4" 4'-1 1/2" 2'-0" 2'-6 7/8" 38'-8" 2'-0" B 5'-0" 6'-0" 5 1/2" STEEL POST PER STRUCTURAL 6'-0" A6.2 LIVING ROOM A6.2 3'-0" 2'-2 1/2" 3" H H 9" A6.2 2'-0" 3'-0" 3'-0" A WINDOWS POST - VERIFY SIZE AND TYPE WITH STRUCTURAL PLAN 13'-11" PROVIDE ILLUMINATION PER IRC R303.6 7'-9 1/2" 3'-0" 2'-2 1/2" DATE: 1. 2. 3. 4. 5. REVISION 1 2-11-2015 REVISION 2 3-10-2015 24'-0" TERRI BELLA RESIDENCES LOT 9 HOUSE VENTILATION 335 PARKPLACE CENTER G119 KIRKLAND, WA 98033 2012 IRC - PROVIDE WHOLE HOUSE VENTILATION PER M1507, INTERMITTENT WHOLE HOUSE VENTILATION USING EXHAUST FAN PER 1507.3 TABLE1507.3.3(1) & TABLE1507.3.3(2), PROVIDE CONTROLS PER 1503.2. COMPLY WITH WSEC R403.5. LOCATION MINIMUM FAN REQUIREMENTS JOB ADDRESS: A Bath & Powder Min. 50 cfm (INTERMITTENT) @ .025" WG (TABLE M1507.3) 328 4TH AVE S KIRKLAND, WA 98033 B Kitchen Min. 100 cfm (INTERMITTENT)@ .025" WG (TABLE M1507.3) (Range hood or down draft exhaust fan rated at min. 100 cfm at 0.10" wg may be used for exhaust fan requirement.) C Laundry Room Min. 180cfm (INTERMITTENT) @ .025" WG - to function and be labeled as whole house fan (4-5 BEDROOMS 3001< 4500 SF.) TO OPERATE 50% OF EVERY FOUR HOUR PERIOD SYMBOL GAS FIREPLACE: DIRECT VENT THROUGH WALL PER MANUFACTURER'S EQUIREMENTS. VERIFY JAMB & HEAD DIMENSIONS FOR REQUIRED NONCOMBUSTIBLE MATERIALS DRYER VENT PER (TABLE M1502.4.4.1) VENTED TO OUTSIDE *ALL FANS TO VENT TO OUTSIDE ALL SHOWERHEAD AND KITCHEN SINK FAUCETS SHALL BE RATED @ 1.75 GPM OR LESS. ALL OTHER LAVATORY FAUCETS SHALL BE RATED @ 1.0 GPM OR LESS. CONTRACTOR TO KEEP PRODUCT LITERATURE ON SITE. 7 A6.4 A6.2 21'-4 1/2" Issue Date PROJECT / CLIENT: 9 1/2" H 3" DOORS SLAB ON GRADE A6.2 7 1 REVISIONS: H 8 EMILY D. BUCHWALTER INTAKE DATE: 3'-0" H 3 1 DECK TYP @ ALL GUARD RAILS CARBON MONOXIDE DETECTOR 2X WALLS 3" H 2 H CO FOUNDATION WALL & FOOTING 5'-0" 2'-4 1/2" 2'-1 3/4" 14'-10 5/8" 2'-6 1/2" 9 LINE OF BUILDING AT 3RD FLOOR ABOVE J R312.3 OPENING LIMITATIONS REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM WALKING SURFACE TO THE REQUIRED HEIGHT WHICH ALLOW PASSAGE OF A SPHERE 4" IN DIAMETER. A6.1 TYPICAL @ ALL WINDOWS A6.2 2 A2.1 SMOKE DETECTOR STATE OF WASHINGTON 3'-0" 5'-0" NOTE: PER IRC 301.5 GUARDS AND HANDRAILS SHALL BE ABLE TO RESIST A SINGLE CONCENTRATED LOAD OF 200 LBS/SF APPLIED IN ANY DIRECTION AT ANY POINT ALONG THE TOP AND TO TRANSFER THIS LOAD THROUGH THE SUPPORTS TO THE STRUCTURE. PER IRC 301.5 SD 3" N 3 OVEN 3'-0" 5 1/2" 2 1/2" 2'-0" 3'-3" 4'-1" 5 1/2" 2'-0" 4'-5" 2'-3 1/2" L REGISTERED ARCHITECT 6926 DINING ROOM 4'-0" 6'-8 1/2" I I TYPICAL 2 @ ALL EXTERIOR A6.1 WALLS 4 1'-5 1/2" H 6'-8" 5'-0" 5'-9 1/2" B F G KITCHEN 11661 SE1st Street, Suite 200 Bellevue, Washington 98005 Tel: (425) 453-9298 Fax: (425) 452-8448 SYMBOL LEGEND IRC R312.1.3 (1) THE TRIANGULAR OPENINGS AT THE OPEN SIDES OF A STAIR, FORMED BY THE RISER,TREAD AND BOTTOM RAIL OF A GUARD, SHALL NOT ALLOW PASSAGE OF A SPHERE 6" IN DIAMETER. IRC R312.1.3 (2) GUARDS ON THE OPEN SIDES OF STAIRS SHALL NOT HAVE OPENING WHICH ALLOWS PASSAGE OF A SPHERE 4 3/8" IN DIAMETER. E N 4 A6.4 City of Kirkland Reviewed by R Braun 03/11/2015 REGISTRATION: NOTE: GUARDS ON THE OPEN SIDES OF STAIRS SHALL NOT HAVE OPENING WHICH ALLOWS PASSAGE OF A SPHERE 4 3/8" IN DIAMETER. 2'-9 1/4" 10" 5'-0 3/4" 3'-6" 3'-1 3/4" 5 1/2" 3'-6" 2'-6" 4'-0" 6'-7 1/2" CO SD 6'-8" 1'-11" 9'-0 3/4" 10" 12'-6 1/2" 4'-11" 5 L 5 10" 2'-6 1/2" 5 R303.7 STAIRWAY ILLUMINATION ALL INTERIOR STAIRWAYS SHALL BE PROVIDED WITH A MEANS TO ILLUMINATE THE STAIRS, INCLUDING THE LANDINGS AND TREADS. STAIRWAY ILLUMINATION SHALL RECEIVE PRIMARY POWER FROM THE BUILDING WIRING. INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED IN THE IMMEDIATE VICINITY OF EACH LANDING OR THE STAIRWAY. FOR INTERIOR STAIRS THE ARTIFICIAL LIGHT SOURCE SHALL BE CAPABLE OF ILLUMINATING TREADS AND LANDINGS TO LEVELS NO LESS THAN 1 FOOT-CANDLE MEASURED AT THE CENTER TREADS AND LANDINGS. AWAY ROOM 2'-0" 5 PANTRY C 6'-7" 4'-9 1/4" 7'-2" 7'-10" 2'-0" 3'-1 3/4" 12. 2'-0" 3'-6" 4'-1 1/2" BATHROOM 2 1'-6" L SD 2'-6" 4'-8 1/2" 9'-2 1/2" A 5'-2 1/2" 6'-8" L 9. 10. L COOKTOP EXHAUST DIRECT VENT TO OUTSIDE HVAC CHASE 6 A6.4 1'-9 1/2" 8. M Egress 8.56 sf L LINE OF BUILDING SETBACK 7 A6.4 N 7 A6.4 PROPERTY LINE 1'-11 1/2" CONTRACTOR SHALL VERIFY ALL NOTES, DIMENSIONS & CONDITIONS PRIOR TO CONSTRUCTION. ALL POSTS, BEAMS & HEADERS SEE STRUCTURAL DRAWINGS PROVIDE SOLID BLOCKING OVER SUPPORTS. PROVIDE FIRE BLOCKING @ ALL PLUMBING PENETRATIONS. WINDOWS & DOORS ARE SHOWN & NOTED AS NOMINAL SIZES. DOOR JAMB 4.5" U.N.O. SEE SHEETS A0.2, A4.0 & A4.1 FOR WINDOW & DOOR HEADER HEIGHTS ABOVE FINISHED FLOOR. ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE TREATED. EXTERIOR WALLS TO BE 2x6 STUDS @ 16" O.C., U.N.O. INSTALL SIMPSON CONC. TO WOOD HOLDOWNS PER STRUCTURAL DRAWINGS, ALSO SEE MANUFACTURER'S SPECS. SMOKE & CARBON MONOXIDE DETECTORS: *SHALL BE 110V INTERCONNECTED W/ BATTERY BACKUP. *SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING ROOMS. *SHALL BE INSTALLED ON EACH FLOOR AND IN ALL BEDROOMS. *SHALL BE INSTALLED IN EACH LOCATION WHERE THERE IS A CEILING CHANGE OF GREATER THAN 24" SEE SHEET A0.1 & A0.2 FOR ADDITIONAL NOTES. 2. 3. 4. 5. 6. 7. 9" 2'-0" 2'-6" B 1. 18'-8" 6'-2" A SIDE SETBACK 2'-0" SIDE SETBACK 5'-0" Architecture Programming Accessible Design Interior Design EAST UNIT DRAWING NAME: 2ND FLOOR PLAN Drawn By: OTR/US Checked By: EB Owner Approval: PHASE: 7'-8 1/2" PERMIT SET 13'-8 1/2" 2 NOTE: AT DECKFIBERGLASS WATERPROOF MEMBRANE OVER 1/2 " THICK MARINE PLYWOOD OVER 3/4 " PLYWOOD, PLYWOOD MUST BE ACX CROSSPLUGGED (NO TONGUE AND GROOVE) UNDERLAYMENT, PLYWOOD SUBSTRATE SHOULD BE INSTALLED JUST PRIOR TO FIBERGLASS LAMINATION PROCESS, PLYWOOD MUST NOT BE ALLOWED TO ABSORB ANY MOISTURE WHAT SO EVER. 5 This drawing is the exclusive property of medici architects, and can be reproduced only with the permission of the architect. variations and modifications to work shown on this drawing shall not be carried out without written permission from the architect. 5 1/2" 8'-0" LINE OF EDGE OF DECK AT 3RD FLOOR ABOVE 2'-1 1/2" 5 1/2" AT EXPOSED DECKSEXPOSED LAYER OF FIBERGLASS MIXTURE TO INCLUDE SAND FOR UV PROTECTION AND PROVIDE SLIP RESISTANCE. FIBERGLASS WATERPROOF MEMBRANE OVER 1/2" THICK PLYWOOD OVER 3/4" PLYWOOD, PLYWOOD MUST BE ACX CROSS-PLUGGED (NO TONGUE AND GROOVE) UNDERLAYMENT, PLYWOOD SUBSTRATE SHOULD BE INSTALLED JUST PRIOR TO FIBERGLASS LAMINATION PROCESS, PLYWOOD MUST NOT BE ALLOWED TO ABSORB ANY MOISTURE WHAT SO EVER. APPROVED FOR CONSTRUCTION: DECK AT 2ND FLOOR H 4 1/8" 7 A6.0 PROPERTY LINE 2 PROPERTY LINE 1 COLUMN AT DECK 1/2" = 1'-0" PROJECT No.: 2014052 DATE/ TIME: 3/10/2015 2:30:44 PM A2.1 2ND FLOOR PLAN 1/4" = 1'-0" PLOT SCALE: 1:1 MEDICI ARCHITECTS PROPERTY LINE 3 1 4 5'-0" 6 30'-0" 11'-4" SIDE SETBACK 5'-0" 9'-7" 9'-1" FLOOR PLAN NOTES SIDE SETBACK A LINE OF BUILDING SETBACK 1. PROPERTY LINE 7 A6.4 A5.0 3'-2" 5'-0" 2. 3. 4. 5. 6. 7. TYP. 3'-2" 11'-8 1/2" 5'-0" LINE OF ROOF ABOVE 1'-11 1/2" D SD 9" 12. 13'-11" A6.1 R303.7 STAIRWAY ILLUMINATION ALL INTERIOR STAIRWAYS SHALL BE PROVIDED WITH A MEANS TO ILLUMINATE THE STAIRS, INCLUDING THE LANDINGS AND TREADS. STAIRWAY ILLUMINATION SHALL RECEIVE PRIMARY POWER FROM THE BUILDING WIRING. INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED IN THE IMMEDIATE VICINITY OF EACH LANDING OR THE STAIRWAY. FOR INTERIOR STAIRS THE ARTIFICIAL LIGHT SOURCE SHALL BE CAPABLE OF ILLUMINATING TREADS AND LANDINGS TO LEVELS NO LESS THAN 1 FOOT-CANDLE MEASURED AT THE CENTER TREADS AND LANDINGS. 7'-4" 2'-0" 5'-0" 8'-7" 2'-9" 2'-6" 24'-9 1/2" 5'-0" 6" 1 CARBON MONOXIDE DETECTOR 1 DOORS A WINDOWS A A SLAB ON GRADE 1. 2. 3. 4. 5. POST - VERIFY SIZE AND TYPE WITH STRUCTURAL PLAN PROJECT / CLIENT: PROVIDE FLOOR SAVER PAN UNDER WASHER WITH TIGHTLINE DRAIN AND PROVIDE DRYER BOX IN WALL FOR DRYER VENT - TO PREVENT COMPROMISING DUCT WORK. O 2012 IRC - PROVIDE WHOLE HOUSE VENTILATION PER M1507, INTERMITTENT WHOLE HOUSE VENTILATION USING EXHAUST FAN PER 1507.3 TABLE1507.3.3(1) & TABLE1507.3.3(2), PROVIDE CONTROLS PER 1503.2. COMPLY WITH WSEC R403.5. SYMBOL LOCATION MINIMUM FAN REQUIREMENTS A Bath & Powder Min. 50 cfm (INTERMITTENT) @ .025" WG (TABLE M1507.3) B Kitchen Min. 100 cfm (INTERMITTENT)@ .025" WG (TABLE M1507.3) (Range hood or down draft exhaust fan rated at min. 100 cfm at 0.10" wg may be used for exhaust fan requirement.) C Laundry Room Min. 180cfm (INTERMITTENT) @ .025" WG - to function and be labeled as whole house fan (4-5 BEDROOMS 3001< 4500 SF.) TO OPERATE 50% OF EVERY FOUR HOUR PERIOD DRYER VENT PER (TABLE M1502.4.4.1) VENTED TO OUTSIDE 2'-0" R312.3 OPENING LIMITATIONS REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM WALKING SURFACE TO THE REQUIRED HEIGHT WHICH ALLOW PASSAGE OF A SPHERE 4" IN DIAMETER. 3'-0" 3" 3'-0" 8'-0" 3" 3'-0" 4'-4" 3'-0" *ALL FANS TO VENT TO OUTSIDE 3'-2" 22'-0" ALL SHOWERHEAD AND KITCHEN SINK FAUCETS SHALL BE RATED @ 1.75 GPM OR LESS. ALL OTHER LAVATORY FAUCETS SHALL BE RATED @ 1.0 GPM OR LESS. CONTRACTOR TO KEEP PRODUCT LITERATURE ON SITE. 30'-0" DECK AT 3RD FLOOR 8'-0" PROPERTY LINE 13'-8 1/2" 2 8'-3 1/2" STEEL BRACE PER STRUCTURAL STEEL TIE ROD PER STRUCTURAL DECK AT 2ND FLOOR 5 BEAM ABOVE PER STRUCTURAL PLANS 2 PROPERTY LINE REVISION 1 2-11-2015 REVISION 2 3-10-2015 HOUSE VENTILATION BEAM ABOVE PER STRUTURAL PLANS 2 A2.2 ENLARGED PLAN AT DECK 1/2" = 1'-0" JOB ADDRESS: 328 4TH AVE S KIRKLAND, WA 98033 EAST UNIT DRAWING NAME: 3RD FLOOR PLAN Drawn By: OTR/US Checked By: EB Owner Approval: PHASE: PERMIT SET This drawing is the exclusive property of medici architects, and can be reproduced only with the permission of the architect. variations and modifications to work shown on this drawing shall not be carried out without written permission from the architect. APPROVED FOR CONSTRUCTION: PROJECT No.: 2014052 DATE/ TIME: 1 3RD FLOOR PLAN 1/4" = 1'-0" DATE: REVISIONS: 2X WALLS 335 PARKPLACE CENTER G119 KIRKLAND, WA 98033 1'-0" A 7'-0" Issue Date INTAKE DATE: TERRI BELLA RESIDENCES LOT 9 3'-0" OPEN GRID DECKING A 1'-0" 3'-0" CO IRC M1507.3.(2) THE WHOLEHOUSE MECHANICAL VENTILATION SYSYTEM SHALL BE PROVIDED WITH CONTROLS THAT ENABLE MANUAL OVERRIDE DECK A6.2 SMOKE DETECTOR FOUNDATION WALL & FOOTING A6.2 8" A6.2 12'-1" 2'-6 1/2" 17'-0 1/4" 6" 2'-5 1/2" MASTER BEDROOM 1 9 8 SD PROVIDE ILLUMINATION PER IRC R303.6 24'-9 1/2" 4'-6" 6" CL 3'-0" 5'-0" EMILY D. BUCHWALTER STATE OF WASHINGTON 12'-9 1/2" 2'-0" 6" 6" 3'-0" 3'-3 1/2" 10 REGISTERED ARCHITECT SYMBOL LEGEND P SD 11661 SE1st Street, Suite 200 Bellevue, Washington 98005 Tel: (425) 453-9298 Fax: (425) 452-8448 6926 8 5 S 8" 8'-2" C A 3'-8" 7'-3 1/2" 4'-3" 4'-5" 2'-3 1/2" LAUDRY 1'-6" 3'-6 1/2" R IRC R312.1.3 (1) THE TRIANGULAR OPENINGS AT THE OPEN SIDES OF A STAIR, FORMED BY THE RISER,TREAD AND BOTTOM RAIL OF A GUARD, SHALL NOT ALLOW PASSAGE OF A SPHERE 6" IN DIAMETER. IRC R312.1.3 (2) GUARDS ON THE OPEN SIDES OF STAIRS SHALL NOT HAVE OPENING WHICH ALLOWS PASSAGE OF A SPHERE 4 3/8" IN DIAMETER. 2'-9 1/4" 2'-10" CO 1 MASTER BATHROOM NOTE: GUARDS ON THE OPEN SIDES OF STAIRS SHALL NOT HAVE OPENING WHICH ALLOWS PASSAGE OF A SPHERE 4 3/8" IN DIAMETER. 5 1/2" 7 2'-7 1/2" SD A A6.5 5 1/2" 1'-5 1/2" 2'-6 1/2" 1'-10" 8" 1'-6" 3'-8 1/2" 11'-11" SHELVES SHWR. 3'-6" 5 2" 32'-6" 6'-5 1/2" A BATHROOM 3 SG 4 A6.4 NOTE: PER IRC 301.5 GUARDS AND HANDRAILS SHALL BE ABLE TO RESIST A SINGLE CONCENTRATED LOAD OF 200 LBS/SF APPLIED IN ANY DIRECTION AT ANY POINT ALONG THE TOP AND TO TRANSFER THIS LOAD THROUGH THE SUPPORTS TO THE STRUCTURE. PER IRC 301.5 City of Kirkland Reviewed by R Braun 03/11/2015 REGISTRATION: 4 1/2" 5 6'-5 1/2" 1'-6" 3'-0" MIN. Q F 6'-8 1/2" 2'-6" DN 5 J 16 RISE @ 7 1/4" 12" ACTUAL RUN 6'-8" 1'-6 1/2" 3'-6" 5'-3 1/2" 6'-8" 6'-9 3/4" 1'-3 1/2" A6.2 5 1/2" 16'-8 1/4" 5'-0" 3'-8 1/2" 5'-0" 5 C 3 SD 9 9'-11" 45'-4 1/2" SD CO 4'-0" 5 2'-1" 6'-0" I 6'-7 1/2" 5'-3 3/4" 5'-0 1/4" 9'-2 1/2" CL BEDROOM 2 G 6'-8" D H 2 A6.2 C G A6.1 2 Egress 10.86 sf E 1 BEDROOM 3 5 9. 10. 11. 5'-5 1/2" 4'-1 1/2" B 8. 2'-0" 1'-6 1/2" 5 K C 2'-6" CL Egress 6.72 sf 8" 4'-8 1/2" 4'-8 1/2" 4'-8 1/2" A CONTRACTOR SHALL VERIFY ALL NOTES, DIMENSIONS & CONDITIONS PRIOR TO CONSTRUCTION. ALL POSTS, BEAMS & HEADERS SEE STRUCTURAL DRAWINGS PROVIDE SOLID BLOCKING OVER SUPPORTS. PROVIDE FIRE BLOCKING @ ALL PLUMBING PENETRATIONS. WINDOWS & DOORS ARE SHOWN & NOTED AS NOMINAL SIZES. DOOR JAMB 4.5" U.N.O. SEE SHEETS A0.2, A4.0 & A4.1 FOR WINDOW & DOOR HEADER HEIGHTS ABOVE FINISHED FLOOR. ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE TREATED. EXTERIOR WALLS TO BE 2x6 STUDS @ 16" O.C., U.N.O. INSTALL SIMPSON CONC. TO WOOD HOLDOWNS PER STRUCTURAL DRAWINGS, ALSO SEE MANUFACTURER'S SPECS. SMOKE & CARBON MONOXIDE DETECTORS: *SHALL BE 110V INTERCONNECTED W/ BATTERY BACKUP. *SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING ROOMS. *SHALL BE INSTALLED ON EACH FLOOR AND IN ALL BEDROOMS. *SHALL BE INSTALLED IN EACH LOCATION WHERE THERE IS A CEILING CHANGE OF GREATER THAN 24" SEE SHEET A0.1 & A0.2 FOR ADDITIONAL NOTES. Architecture Programming Accessible Design Interior Design 3/10/2015 2:30:45 PM A2.2 PLOT SCALE: 1:1 MEDICI ARCHITECTS PROPERTY LINE 3 1 2 10'-10" 8'-0" 4 5 6 3'-4" 9'-7" 9 1/2" 8'-3 1/2" PROPERTY LINE A 6" SQUARE DOWNSPOUT A5.0 FLOOR PLAN NOTES 6 DIRECTION OF INTERNAL GUTTER SLOPE 6" SQUARE DOWNSPOUT A6.2 1'-6" 6" SQUARE GUTTER WITH INTERNAL SLOPE 6'-2 1/2" A 4'-8 1/2" Architecture Programming Accessible Design Interior Design 30'-0" B 1. CONTRACTOR SHALL VERIFY ALL NOTES, DIMENSIONS & CONDITIONS PRIOR TO CONSTRUCTION. ALL POSTS, BEAMS & HEADERS SEE STRUCTURAL DRAWINGS PROVIDE SOLID BLOCKING OVER SUPPORTS. PROVIDE FIRE BLOCKING @ ALL PLUMBING PENETRATIONS. WINDOWS & DOORS ARE SHOWN & NOTED AS NOMINAL SIZES. DOOR JAMB 4.5" U.N.O. SEE SHEETS A0.2, A4.0 & A4.1 FOR WINDOW & DOOR HEADER HEIGHTS ABOVE FINISHED FLOOR. ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE TREATED. EXTERIOR WALLS TO BE 2x6 STUDS @ 16" O.C., U.N.O. INSTALL SIMPSON CONC. TO WOOD HOLDOWNS PER STRUCTURAL DRAWINGS, ALSO SEE MANUFACTURER'S SPECS. SMOKE & CARBON MONOXIDE DETECTORS: *SHALL BE 110V INTERCONNECTED W/ BATTERY BACKUP. *SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING ROOMS. *SHALL BE INSTALLED ON EACH FLOOR AND IN ALL BEDROOMS. *SHALL BE INSTALLED IN EACH LOCATION WHERE THERE IS A CEILING CHANGE OF GREATER THAN 24" SEE SHEET A0.1 & A0.2 FOR ADDITIONAL NOTES. 2. 3. 4. 5. 6. 7. 4 8. A6.2 9. 10. 11. 1'-6" 11661 SE1st Street, Suite 200 Bellevue, Washington 98005 Tel: (425) 453-9298 Fax: (425) 452-8448 REGISTRATION: 9'-2 1/2" 12. City of Kirkland Reviewed by R Braun 03/11/2015 UN-VENTED CAVITY - 4" ICYNENE CLOSED-CELL WATER-BASED SPRAY FOAM INSULATION R-7 PER INCH; R-21 BATT; TOTAL R-VALUE: R-49 C REGISTERED ARCHITECT 6926 SYMBOL LEGEND EMILY D. BUCHWALTER STATE OF WASHINGTON SLOPE: 1/4" = 1'-0" 58'-2" 6'-8" 1'-11 1/2" 4'-1 1/2" 45'-4 1/2" D E SD SMOKE DETECTOR CO CARBON MONOXIDE DETECTOR 1 DOORS A WINDOWS 2X WALLS FOUNDATION WALL & FOOTING 5'-9 1/2" LINE OF BUILDING BELOW TPO WATERPROOFING ROOFING SYSTEM PER IRC R905.13.(2) F Issue Date INTAKE DATE: DATE: REVISIONS: 1. 2. 3. 4. 5. REVISION 1 2-11-2015 REVISION 2 3-10-2015 SLAB ON GRADE POST - VERIFY SIZE AND TYPE WITH STRUCTURAL PLAN PROJECT / CLIENT: TERRI BELLA RESIDENCES LOT 9 1'-6" 4'-5" 335 PARKPLACE CENTER G119 KIRKLAND, WA 98033 1'-5 1/2"2'-3 1/2" G H I JOB ADDRESS: 1'-6" 328 4TH AVE S KIRKLAND, WA 98033 EAST UNIT 5 A6.2 10'-1 1/2" 6'-8 1/2" 9'-6" EAVE PER IRC R302.1(1) 2'-9" 1'-11 1/2" J DRAWING NAME: 6 A6.1 HARDIE BOARD SOFFIT ROOF PLAN Drawn By: US Checked By: EB Owner Approval: PHASE: This drawing is the exclusive property of medici architects, and can be reproduced only with the permission of the architect. variations and modifications to work shown on this drawing shall not be carried out without written permission from the architect. 23'-9 1/2" 21'-10" PERMIT SET APPROVED FOR CONSTRUCTION: PROPERTY LINE PROJECT No.: 2014052 DATE/ TIME: 3/10/2015 2:30:46 PM PROPERTY LINE 1 A3.0 ROOF PLAN 1/4" = 1'-0" PLOT SCALE: 1:1 1 2 3 4 5 MEDICI ARCHITECTS 6 CEDAR T&G HORIZONTAL SIDING WITH 4" EXPOSURE 8" CEDAR FASCIA, TYP. HARDIE LAP HORIZONTAL SIDING WITH 8" EXPOSURE, PAINTED MAXIMUM HEIGHT 136.12 GALVANIZED METAL CAP AT EXTERIOR EXPOSED WOOD BEAM PER STRUCTURAL ELEVATION NOTES: 3" 3" SG SG 5'-8" LIGTHING AT ALL EXTERIOR DOORS, TYP. CLOPAY ALUMINUM GARAGE DOOR WITH CLEAR COAT FINISH DOWNSPOUT REGISTRATION: 9' - 0" 2ND FLOOR 116.27 REGISTERED ARCHITECT 6926 1 STEEL POST PER STRUCTURAL SG 1'-4" EMILY D. BUCHWALTER STATE OF WASHINGTON 1ST FLOOR 107.27 LOCATION OF HOUSE ADDRESS OR NUMBER TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET DATE: REVISIONS: 1. 2. 3. 4. 5. PER IRC R312.2 OPERABLE SECTIONS OF WINDOWS SHALL NOT PERMIT OPENINGS THAT ALLOW PASSAGE OF A 4-INCHDIAMETER(102mm) SPHERE WHERE SUCH OPENINGS ARE LOCATED WITHIN 24 INCHES (610mm) OF THE FINISHED FLOOR, TYP. SOUTH ELEVATION 1/4" = 1'-0" Issue Date INTAKE DATE: ABE 106.12 CONCRETE SLAB PER STRUCTURAL 1 11661 SE1st Street, Suite 200 Bellevue, Washington 98005 Tel: (425) 453-9298 Fax: (425) 452-8448 CEDAR T&G HORIZONTAL SIDING WITH 4" EXPOSURE SG NORSTONE ROCK PANELS (CHARCOAL) City of Kirkland Reviewed by R Braun 03/11/2015 8' - 0" A 2 PER IRC 301.5 GUARDS AND HANDRAILS SHALL BE ABLE TO RESIST A SINGLE CONCENTRATED LOAD OF 200 LBS/SF APPLIED IN ANY DIRECTION AT ANY POINT ALONG THE TOP AND TO TRANSFER THIS LOAD THROUGH THE SUPPORTS TO THE STRUCTURE. PER IRC 301.5 1' - 0" 1'-0" SG 8. VERIFY SHEAR WALL NAILING & HOLDOWNS PER STRUCTURAL PLAN &SCHEDULE PRIOR TO INSTALLING SIDING. MASONRY & WOOD FRAME CHIMNEYS ARE TO BE CONSTRUCTED PER I.R.C. CHAPTER 10. CAULK ALL EXTERIOR JOINTS & PENETRATIONS. PROVIDE APPROVED CORROSION RESISTANT FLASHING AT EXTERIOR WALL ENVELOPE PER I.R.C. R703.8. PROVIDE FLASHING AT ROOF PENETRATIONS PER I.R.C. R903.2 & R903.2.1. PROVIDE WEATHER STRIPPING AT ALL EXTERIOR & GARAGE-INTERIOR DOORS. PROVIDE CONTINUOUS GUTTERS & DOWN SPOUTS @ ALL EAVES, TYP. SEE SHEET A0.1 FOR ADDITIONAL NOTES. NOTE: GUARDS ON THE OPEN SIDES OF STAIRS SHALL NOT HAVE OPENING WHICH ALLOWS PASSAGE OF A SPHERE 4 3/8" IN DIAMETER 7'-0" HEAD HEIGHT NOTE: TOP OF PATIO DECK TO BE 1/2" LOWER THAN FLOOR, TYP. 8'-0" HEAD HEIGHT 7'-0" 8'-0" SG 7. 3RD FLOOR 126.27 HARDIE LAP HORIZONTAL SIDING WITH 4" & 8" EXPOSURE, PAINTED PATTERN AS SHOWN H 7'-0" H 1'-0" 3'-0" REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE WALKING SURFACE TO THE REQUIRE GUARD HEIGHT WHICH ALLOW PASSAGE OF A SPHERE 4 INCHES IN DIAMETER 3'-0" N 5'-0" H 5. 6. 3" STEEL BEAM PER STRUCTURAL 3. 4. 1' - 0" 3'-7" METAL FASCIA AT DECK 2. FIREPLACE EXHAUST VENT. SEE DETAIL 3/A6.4 1'-4" 3'-0" SG 5'-4" 5'-8" 5'-8" S SG CEDAR T&G HORIZONTAL SIDING WITH 4" EXPOSURE 30'-0" O 7' - 10" A 7'-0" HEAD HEIGHT A 1'-4" OPEN GRID DECKING 2'-10" 4'-2" A 1'-8" 1. STEEL BRACE AND TIE ROD PER STRUCTURAL Architecture Programming Accessible Design Interior Design REVISION 1 2-11-2015 REVISION 2 3-10-2015 PROJECT / CLIENT: TERRI BELLA RESIDENCES LOT 9 A B C D E F G H I J 335 PARKPLACE CENTER G119 KIRKLAND, WA 98033 8" FASCIA, TYP. TIGHTLINE ALL DOWNSPOUTS TO STORM WATER SYSTEM PER CIVIL DRAWINGS, TYP. MAXIMUM HEIGHT 136.12 GALVANIZED METAL CAP AT EXTERIOR EXPOSED WOOD BEAM PER STRUCTURAL SG 1'-4" 3RD FLOOR 126.27 SG PHASE: PERMIT SET 2ND FLOOR 116.27 SG This drawing is the exclusive property of medici architects, and can be reproduced only with the permission of the architect. variations and modifications to work shown on this drawing shall not be carried out without written permission from the architect. NORSTONE ROCK PANELS (CHARCOAL). SEE DETAIL 7/A6.3 SG 8' - 0" APPROVED FOR CONSTRUCTION: STEEL POST PER STRUCTURAL 5'-8" SG G 14.9% 1'-4" 7'-0" HEAD HEIGHT NOTE: TOP OF PATIO DECK TO BE 1/2" LOWER THAN FLOOR, TYP. 1 ELEVATIONS Drawn By: OTR/US Checked By: EB Owner Approval: 30'-0" SG LIGHTING AT ALL EXTERIOR DOORS, TYP. HARDIE LAP HORIZONTAL SIDING WITH 4" & 8" EXPOSURE, PAINTED PATTERN AS SHOWN REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE WALKING SURFACE TO THE REQUIRE GUARD HEIGHT WHICH ALLOW PASSAGE OF A SPHERE 4 INCHES IN DIAMETER, TYP. 9' - 0" H 7'-0" 5'-0" 3'-0" 5'-0" 3'-0" 5'-0" 3'-0" 5'-0" 3'-0" 4 DRAWING NAME: METAL FASCIA AT DECK 8" WOOD FRAMED CANOPY WITH METAL FASCIA PER STRUCTURAL L OPEN GRID DECKING STEEL BEAM PER STRUCTURAL 1'-0" N L 8'-0" HEAD HEIGHT L 3" EAST UNIT 1' - 0" 5 1/2" HARDIE LAP HORIZONTAL SIDING WITH 6" EXPOSURE, PAINTED STEEL BRACE AND TIE ROD PER STRUCTURAL 1' - 0" SG 2'-10" SG 1'-4" SG SG 5'-8" Egress 10.86 sf 328 4TH AVE S KIRKLAND, WA 98033 7' - 10" A 1 CEDAR T&G HORIZONTAL SIDING WITH 4" EXPOSURE 3'-0" R 3'-0" O 4'-2" 5'-8" 7'-0" HEAD HEIGHT G 5'-4" NOTE: WINDOW EGRESS - MINIMUM OPENING HEIGHT SHALL BE 24 INCHES PER IRC R310.1.2 & MINIMUM OPENING WIDTH SHALL BE 20 INCHES PER IRC R310.1.3. 1'-8" 8" JOB ADDRESS: 1ST FLOOR 107.27 2.0% ABE 106.12 CONCRETE SLAB PER STRUCTURAL 2 4" CONCRETE SLAB PER STRUCTURAL HARDIE LAP HORIZONTAL SIDING WITH 8" EXPOSURE, PAINTED PROJECT No.: 2014052 MIN. 6" CLEARANCE FROM GRADE DATE/ TIME: 3/10/2015 2:30:47 PM A4.0 WEST ELEVATION 1/4" = 1'-0" PLOT SCALE: 1:1 6 5 4 3 2 MEDICI ARCHITECTS 1 GUTTER WITH INTERNAL SLOPE 8" FASCIA,TYP. 1'-8" MAXIMUM HEIGHT 136.12 5'-4" Egress 6.72 sf 1' - 0" 1'-0 3/8" WOOD FRAMED CANOPY WITH METAL FASCIA PER STRUCTURAL 1. MAXIMUM BUILDING HEIGHT 9' - 0" 5'-0" 3'-0" HARDIE LAP HORIZONTAL SIDING WITH 6" EXPOSURE, PAINTED 3'-0" 3'-0" Egress 8.56 sf 30'-0" L 5'-0" N 5'-0" M 8'-0" HEAD HEIGHT NOTE: WINDOW EGRESS - MINIMUM OPENING HEIGHT SHALL BE 24 INCHES PER IRC R310.1.2 & MINIMUM OPENING WIDTH SHALL BE 20 INCHES PER IRC R310.1.3. ELEVATION NOTES: 3RD FLOOR 126.27 1' - 0" 4'-0" 6" SQUARE GUTTER & DOWNSPOUTS TIGHTLINE TO SORMWATER SYSTEM PER CIVIL DRAWINGS, TYP. 7' - 10" 7'-0" HEAD HEIGHT K 4'-0" D Architecture Programming Accessible Design Interior Design 2. 3. 4. 5. 6. 7. 8. VERIFY SHEAR WALL NAILING & HOLDOWNS PER STRUCTURAL PLAN &SCHEDULE PRIOR TO INSTALLING SIDING. MASONRY & WOOD FRAME CHIMNEYS ARE TO BE CONSTRUCTED PER I.R.C. CHAPTER 10. CAULK ALL EXTERIOR JOINTS & PENETRATIONS. PROVIDE APPROVED CORROSION RESISTANT FLASHING AT EXTERIOR WALL ENVELOPE PER I.R.C. R703.8. PROVIDE FLASHING AT ROOF PENETRATIONS PER I.R.C. R903.2 & R903.2.1. PROVIDE WEATHER STRIPPING AT ALL EXTERIOR & GARAGE-INTERIOR DOORS. PROVIDE CONTINUOUS GUTTERS & DOWN SPOUTS @ ALL EAVES, TYP. SEE SHEET A0.1 FOR ADDITIONAL NOTES. City of Kirkland Reviewed by R Braun 03/11/2015 11661 SE1st Street, Suite 200 Bellevue, Washington 98005 Tel: (425) 453-9298 Fax: (425) 452-8448 REGISTRATION: 2ND FLOOR 116.27 REGISTERED ARCHITECT 6926 1'-4" SG 8' - 0" 7'-0" HEAD HEIGHT 5'-8" Egress 10.86 sf SG 3'-0" 3'-0" F 4'-0" E 4'-0" D EMILY D. BUCHWALTER STATE OF WASHINGTON 1ST FLOOR 107.27 MIN. 6" CLEARANCE FROM GRADE DATE: REVISIONS: CONCRETE SLAB PER STRUCTURAL R312.2.1 - WINDOW SILLS. IN DWELLING UNITS, WERE THE OPENING OF AN OPERABLE WINDOW IS LOCATED MORE THAN 72I ABOVE THE FINISHED GRADE OR SURFACE BELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW SHALL BE A MINIMUM OF 24 INCHES ABOVE THE FINISHED FLOOR OF THE ROOM IN WHICH THE WINDOW IS LOCATED. OPERABLE SECTION OF WINDOWS SHALL NOT PERMIT OPENINGS THAT ALLOW PASSAGE OF A 4 INCH DIAMETER SPHERE WHERE SUCH OPENINGS ARE LOCATED WITHIN 24 INCHES OF THE FINISHED FLOOR. LIGHTING AT ALL EXTERIOR DOORS, TYP. 1 Issue Date INTAKE DATE: ABE 106.12 HARDIE LAP HORIZONTAL SIDING WITH 8" EXPOSURE NORTH ELEVATION 1/4" = 1'-0" 1. 2. 3. 4. 5. REVISION 1 2-11-2015 REVISION 2 3-10-2015 PROJECT / CLIENT: J I H G F E D C B A PER IRC 301.5 GUARDS AND HANDRAILS SHALL BE ABLE TO RESIST A SINGLE CONCENTRATED LOAD OF 200 LBS/SF APPLIED IN ANY DIRECTION AT ANY POINT ALONG THE TOP AND TO TRANSFER THIS LOAD THROUGH THE SUPPORTS TO THE STRUCTURE. PER IRC 301.5 8" FASCIA NOTE: GUARDS ON THE OPEN SIDES OF STAIRS SHALL NOT HAVE OPENING WHICH ALLOWS PASSAGE OF A SPHERE 4 3/8" IN DIAMETER 335 PARKPLACE CENTER G119 KIRKLAND, WA 98033 MAXIMUM HEIGHT 136.12 SLOPE 1/4" PER 12" EXTERIOR EXPOSED WOOD BEAM PER STRUCTURAL TERRI BELLA RESIDENCES LOT 9 JOB ADDRESS: CEDAR T&G HORIZONTAL SIDING WITH 4" EXPOSURE 328 4TH AVE S KIRKLAND, WA 98033 SG 7'-10" EAST UNIT DRAWING NAME: 3RD FLOOR 126.27 SG SG SG 2.0% 4'-0" C 3'-0" SG 1'-6" STEEL POST PER STRUCTURAL 14.9% 4'-8" NORSTONE ROCK PANELS (CHARCOAL). SEE DETAIL 7/A6.3 3'-0" SG 5'-6" SG 4'-0" B C 7'-0" HEAD HEIGHT 7'-0" NOTE: TOP OF PATIO DECK TO BE 1/2" LOWER THAN FLOOR, TYP. LIGHTING AT ALL EXTERIOR DOORS, TYP. PERMIT SET 1'-0" 1'-0" 1'-0" J PHASE: 2ND FLOOR 116.27 This drawing is the exclusive property of medici architects, and can be reproduced only with the permission of the architect. variations and modifications to work shown on this drawing shall not be carried out without written permission from the architect. APPROVED FOR CONSTRUCTION: 8'-0" SG 3'-0" SG 3'-0" 6'-4" LINE OF STAIR LANDING 30'-0" L 9'-0" L ELEVATIONS Drawn By: US Checked By: EB Owner Approval: SG K 8'-0" HEAD HEIGHT SG 5'-0" I 5'-0" H 3'-6 1/4" H 7'-0" SG 3'-0" REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE WALKING SURFACE TO THE REQUIRE GUARD HEIGHT WHICH ALLOW PASSAGE OF A SPHERE 4 INCHES IN DIAMETER H 7'-0" NOTE: STEEL BEAM PER STRUCTURAL WINDOW EGRESS - MINIMUM OPENING HEIGHT SHALL BE 24 INCHES PER IRC R310.1.2 & MINIMUM OPENING WIDTH SHALL BE 20 INCHES PER IRC R310.1.3. 1'-8" 1'-0" SG 7'-0" HEAD HEIGHT 4'-0" C 3'-0" STEEL FASCIA AT DECK C 7'-0" P 2'-10" HARDIE LAP HORIZONTAL SIDING WITH 4" & 8" EXPOSURE, PAINTED PATTERN AS SHOWN 3'-0" 4'-2" 4'-0" Q 1ST FLOOR 107.27 ABE 106.12 TIGHTLINE ALL DOWNSPOUTS TO STORM WATER SYSTEM PER CIVIL DRAWINGS, TYP. 4" CONCRETE SLAB PER STRUCTURAL LINE OF STAIR LANDING OPERABLE SECTIONS OF WINDOWS SHALL NOT PERMIT OPENINGS THAT ALLOW PASSAGE OF A 4-INCHDIAMETER(102mm) SPHERE WHERE SUCH OPENINGS ARE LOCATED WITHIN 24 INCHES (610mm) OF THE FINISHED FLOOR, TYP. PER IRC R312.2 2 EAST ELEVATION 1/4" = 1'-0" CEDAR T&G HORIZONTAL SIDING WITH 4" EXPOSURE HARDIE LAP HORIZONTAL SIDING WITH 4" & 8" EXPOSURE, PAINTED HARDIE LAP HORIZONTAL SIDING WITH 4" & 8" EXPOSURE, PAINTED PATTERN AS SHOWN PROJECT No.: 2014052 HARDIE LAP HORIZONTAL SIDING WITH 6" EXPOSURE, PAINTED OPERABLE SECTIONS OF WINDOWS SHALL NOT PERMIT OPENINGS THAT ALLOW PASSAGE OF A 4-INCHDIAMETER(102mm) SPHERE WHERE SUCH OPENINGS ARE LOCATED WITHIN 24 INCHES (610mm) OF THE FINISHED FLOOR, TYP. PER IRC R312.2 DATE/ TIME: 3/10/2015 2:30:48 PM A4.1 PLOT SCALE: 1:1 MEDICI ARCHITECTS Architecture Programming Accessible Design Interior Design City of Kirkland Reviewed by R Braun 03/11/2015 11661 SE1st Street, Suite 200 Bellevue, Washington 98005 Tel: (425) 453-9298 Fax: (425) 452-8448 REGISTRATION: REGISTERED ARCHITECT 6926 EMILY D. BUCHWALTER STATE OF WASHINGTON Issue Date INTAKE DATE: DATE: REVISIONS: 1 3D View 1 2 3D View 2 1. 2. 3. 4. 5. REVISION 1 2-11-2015 REVISION 2 3-10-2015 PROJECT / CLIENT: TERRI BELLA RESIDENCES LOT 9 335 PARKPLACE CENTER G119 KIRKLAND, WA 98033 JOB ADDRESS: 328 4TH AVE S KIRKLAND, WA 98033 EAST UNIT DRAWING NAME: PERSPECTIVES Drawn By: US Checked By: EB Owner Approval: PHASE: PERMIT SET This drawing is the exclusive property of medici architects, and can be reproduced only with the permission of the architect. variations and modifications to work shown on this drawing shall not be carried out without written permission from the architect. APPROVED FOR CONSTRUCTION: PROJECT No.: 2014052 3 3D View 3 4 3D View 4 DATE/ TIME: 3/10/2015 2:30:53 PM A4.2 PLOT SCALE: 1:1 THERMAL INSULATION: (Prescriptive Option III of the WSEC) Walls (below-grade, exterior): R-10 rigid insulation Walls (below-grade, interior): R-21 batt or rigid insulation Walls (above-grade): R-21 batt or rigid insulation Headers R-10 rigid insulation Ceilings (advanced framing): R-38 batt Ceilings (standard framing): R-49 batt Ceilings (vaulted): Icynene with R value of 4.9 per inch Floors: R-30 batt or rigid insulation Slab: R-10 water-resistant rigid insulation 24" @ Perimeter solid doors U-value of .20 or better Windows & doors with glazing U-value of .30 or better skylights U-value of .50 or better THERMAL INSULATION: (PER WSEC 2012 TABLE R402.1.1, REFER TO TABLE FOOTNOTES FOR ADDITIONAL INFORMATION) FENESTRATION U-FACTOR .30 SKYLIGHT U-FACTOR .50 GLAZED FENESTRATION SGHC NR CEILING R-VALUE 49 WOOD FRAME WALL R-VALUE 21 INT (FRAMING @ 16" O.C., R-10 MIN. @ HEADERS) MASS WALL R-VALUE 21 / 21 FLOOR R-VALUE 30 BELOW GRADE WALL R-VALUE 21 INT (FURRED WALL FRAMING @ 16" O.C.,) + THERMAL BREAK BETWEEN SLAB AND BASEMENT WALL. SLAB R-VALUE & DEPTH 10, 2FT. (FOR HEATED SLABS, INSULATION TURNED UP SIDES & CONTINUOUS UNDER ENTIRE SLAB). PROPERTY LINE D F G I J 4 A6.2 WATERPROOF TPO MEMBRANE SYSTEM ROOFING UN-VENTED CAVITY - 4" ICYNENE CLOSED-CELL WATER-BASED SPRAY FOAM INSULATION R-7 PER INCH; R-21 BATT; TOTAL R-VALUE: R-49 NOTE: REFER TO STRUCTURAL PLAN FOR ALL FRAMING INFORMATION 2X ROOF FRAMING PER STRUCTURAL PLAN 6 A6.1 6 A6.2 11661 SE1st Street, Suite 200 Bellevue, Washington 98005 Tel: (425) 453-9298 Fax: (425) 452-8448 CLASS I OR II VAPOR RETARDER INSTALLED ON THE WARM-INWINTER SIDE OF THE CEILING HARDIE PANEL AT SOFFIT, VENTED EAVE BEAM PER STRUCTURAL SLOPE 14/" PER 12" MAXIMUM HEIGHT 136.12 8" STRUCTURAL FASCIA EXPOSED WOOD BEAM WITH GALVANISED METAL CAP PER STRUCTURAL 2X8 FASCIA, HARDIE PANEL SOFFIT STEEL TIE ROD PER STRUCTURAL BEDROOM 3 LAUNDRY R312.3 OPENING LIMITATIONS REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM WALKING SURFACE TO THE REQUIRED HEIGHT WHICH ALLOW PASSAGE OF A SPHERE 4" IN DIAMETER. COVERED DECK STEEL POST PER STRUCTURAL NOTE: AT DECKSFIBERGLASS WATERPROOF MEMBRANE OVER 1/2 " THICK MARINE PLYWOOD OVER 3/4 " PLYWOOD, PLYWOOD MUST BE ACX CROSSPLUGGED (NO TONGUE AND GROOVE) UNDERLAYMENT, PLYWOOD SUBSTRATE SHOULD BE INSTALLED JUST PRIOR TO FIBERGLASS LAMINATION PROCESS, PLYWOOD MUST NOT BE ALLOWED TO ABSORB ANY MOISTURE WHAT SO EVER. 7'-10" 5/8" GWB @ CEILINGS, TYP. FLOOR JOIST PER STRUCTURAL DRAWINGS OPEN GRID DECKING METAL FASCIA AT DECK STEEL POST PER STRUCTURAL AWAY ROOM DINING COVERED DECK FLOOR JOIST PER STRUCTURAL DRAWINGS R-10 INSULATION @ HEADERS TYP. 7 3/4" 7 A6.2 SLOPE 1/4" PER 12" 5 A6.0 WOOD FRAMED CANOPY WITH METL FASCIA PER STRUCTURAL R-30 BATT INSULATION @ FLOORS BETWEEN HEATED AND UNHEATED SPACES TYP. 7 A6.3 COVERED PATIO GUEST ROOM PER IRC 301.5 GUARDS AND HANDRAILS SHALL BE ABLE TO RESIST A SINGLE CONCENTRATED LOAD OF 200 LBS/SF APPLIED IN ANY DIRECTION AT ANY POINT ALONG THE TOP AND TO TRANSFER THIS LOAD THROUGH THE SUPPORTS TO THE STRUCTURE. 4" CONCRETE SLAB ON GRADE SLOPE 3" TO FRONT EMILY D. BUCHWALTER STATE OF WASHINGTON AT EXPOSED DECKSEXPOSED LAYER OF FIBERGLASS MIXTURE TO INCLUDE SAND FOR UV PROTECTION AND PROVIDE SLIP RESISTANCE. FIBERGLASS WATERPROOF MEMBRANE OVER 1/2" THICK PLYWOOD OVER 3/4" PLYWOOD, PLYWOOD MUST BE ACX CROSS-PLUGGED (NO TONGUE AND GROOVE) UNDERLAYMENT, PLYWOOD SUBSTRATE SHOULD BE INSTALLED JUST PRIOR TO FIBERGLASS LAMINATION PROCESS, PLYWOOD MUST NOT BE ALLOWED TO ABSORB ANY MOISTURE WHAT SO EVER. Issue Date INTAKE DATE: DATE: 2ND FLOOR 116.27 1. 2. 3. 4. 5. REVISION 1 2-11-2015 REVISION 2 3-10-2015 PROJECT / CLIENT: TERRI BELLA RESIDENCES LOT 9 WOOD DECKING OVER FIBERGLASS WATERPROOF SYSTEM GARAGE 107.27 REGISTERED ARCHITECT 6926 REVISIONS: 8'-0" 2X6 STUD WALLS ASSEMBLE WITH 1/2" GWB AND R-21 INSULATION, TYP. 1'-0" 1 A6.3 9'-0" R312.3 OPENING LIMITATIONS REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM WALKING SURFACE TO THE REQUIRED HEIGHT WHICH ALLOW PASSAGE OF A SPHERE 4" IN DIAMETER. BEAM PER STRUCTURAL 30'-0" STEEL BEAM PER STRUCTURAL 3RD FLOOR 126.27 1'-0" SLOPE 1/4" PER 12" SIDING PER ELEVATION OVER 15 LB. BUILDING PAPER OVER SHEATHING PER PLAN REGISTRATION: STEEL BRACE PER STRUCTURAL 1'-11 1/2" 1'-6" 6" SQUARE GUTTER Architecture Programming Accessible Design Interior Design City of Kirkland Reviewed by R Braun 03/11/2015 PROPERTY LINE C MEDICI ARCHITECTS 335 PARKPLACE CENTER G119 KIRKLAND, WA 98033 14.9% LINE OF SETBACK 2.0% 1ST FLOOR 107.27 ABE 106.12 JOB ADDRESS: 328 4TH AVE S KIRKLAND, WA 98033 EAST UNIT DRAWING NAME: 3 A6.0 10'-0" REAR YARD SETBACK FOOTINGS PER STRUCTURAL PLAN DIRECT CONNECT FOOTING DRAINS AND DOWNSPOUTS TO DESIGNED STORM WATER SYSTEM SEE CIVIL DRAWINGS FOR CONNECTION R-30 INSULATION IN FLOOR SYSTEM, CLASS 1 VAPOR RETARDER OVER GRADE AND UP STEM WALLS, MIN. 6 MIL. NOTE: REFER TO STRUCTURAL PLAN FOR ALL FRAMING INFORMATION 6 MIL. BLACK V.B. ON UNDERSIDE OF SLAB FOOTINGS PER STRUCTURAL PLAN 2 A6.0 TRENCH DRAIN - TIGHTLINE CONNECT TO EXISTING STORM DRAIN SYSTEM LINE OF SETBACK 20'-0" SECTION A Drawn By: US Checked By: EB Owner Approval: FRONT SETBACK PHASE: A SECTION A 1/4" = 1'-0" PERMIT SET This drawing is the exclusive property of medici architects, and can be reproduced only with the permission of the architect. variations and modifications to work shown on this drawing shall not be carried out without written permission from the architect. APPROVED FOR CONSTRUCTION: PROJECT No.: 2014052 DATE/ TIME: 3/10/2015 2:30:54 PM A5.0 PLOT SCALE: 1:1 MEDICI ARCHITECTS FRAMING & FOUNDATION DIMENSION STEM WALL BEYOND R 30 BATT INSULATION TURN DOWN SLAB INTO CONTINUOUS FOOTING FINISH PER ELEVATION 3/4" T.G. PLYWOOD SUBFLOOR GLUED & NAILED R-30 BATT INSULATION 6" MIN. 10" MIN. TIGHTLINE DOWNSPOUTS TO EXISTING STORMWATER SYSTEMU.N.O 4" DIA. PERF. FOUNDATION DRAIN - TIGHTLINE FOOTING DRAINS TO EXISTING STORMWATER SYSTEM City of Kirkland Reviewed by R Braun 03/11/2015 18" MIN. REBAR PER STRUCTURAL DRAWINGS 6 MIL. BLACK V.B. CLR. REBAR PER STRUCTURAL DRAWINGS P.T. SILL PLATE & A.B. PER SHEAR WALL SCHEDULE AND/OR FOUNDATION PLAN REBAR PER STRUCTURAL DRAWINGS FOOTING PER FOOTING PER STRUCTURAL PLANS STRUCTURAL PLANS CRAWL SPACE FLR. JSTS. PER PLAN 0' - 3" VERIFY TRENCH DRAIN - TIGHTLINE CONNECT TO EXISTING COMBINNED SYSTEM 16" MIN. 30" MAX. UNBALANCED BACKFILL CONCRETE DRIVEWAY REBAR PER STRUCTURAL DRAWINGS VERIFY REBAR PER STRUCTURAL DRAWINGS GARAGE SLAB Architecture Programming Accessible Design Interior Design 2X8 STUDS PER PLAN 11661 SE1st Street, Suite 200 Bellevue, Washington 98005 Tel: (425) 453-9298 Fax: (425) 452-8448 REGISTRATION: REGISTERED ARCHITECT 6926 2 FOUNDATION @ TRENCH GRADE 1" = 1'-0" 3 FOUNDATION @ CRAWL SPACE 1" = 1'-0" EMILY D. BUCHWALTER STATE OF WASHINGTON ENVELOPE NOTE 1: USE MANUFACTURER PROVIDED AND/OR APPROVED FASTENERS AND ACCESSORIES FOR INSTALLATION OF MIRADRAIN DRAINAGE COMPOSITE LIVING AREA NOTE 2: APPLY MECHANICALLY ATTACHED TERM BAR PRIOR TO BACKFILL. CCW-500-R REINFORCED HOT APPLIED WATERPROOFING MEMBRANE CONC. FOUNDATION WALL ANCHOR DRAINAGE BOARD USING SPRAY GLUE PER MANUF. INSTALLTION INSTR. DATE: REVISIONS: 1. 2. 3. 4. 5. CCW MIRADRAIN 6200 DRAINAGE COMPOSITE 6" WIDE DCH REINFORCING FABRIC EMBEDDED IN CCW-500-R HOT APPLIED WATERPROOFING MEMBRANE AT COLD JOINTS ONLY BACKFILL - MATERIAL AS APPROVED BY GEOTECHNICAL ENGINEER OVERLAP DRAINAGE BD. HORIZ. & VERT. JOINTS MIN. 6" - ALIGN DIMPLES AND FASTEN @ 8" O.C. Issue Date INTAKE DATE: 5/8" TYPE X GYPSUM BOARD REVISION 1 2-11-2015 REVISION 2 3-10-2015 FILTER FABRIC CONTINUOUS CARLISLE MIRASTOP @ ALL VERICAL & HORIZONTAL COLD JOINTS 1/2" GYPSUM BOARD LIVING AREA MIXED DRAIN ROCK - PROVIDE 18"-24" COVER ABOVE DRAIN LINES, 2" MIN. BELOW SOLID PIPE TIGHTLINE PER CIVIL / ARCHITECT GARAGE 2" - 4" CONTINOUS CARLISLE MIRASTOP CCW LM-800XL CANT STRIP WATERSTOP FILLET WTIH 3/4" MIN FACE TREE PROTECTION DETAIL 3" = 1'-0" 4 FOUNDATION DRAINAGE 1" = 1'-0" TERRI BELLA RESIDENCES LOT 9 CONCRETE SLAB ON GRADE PERFORATED DRAIN LINES PER CIVIL / ARCHITECT JOB ADDRESS: 328 4TH AVE S KIRKLAND, WA 98033 FILTER FABRIC CONC. FOOTING 1 PROJECT / CLIENT: 335 PARKPLACE CENTER G119 KIRKLAND, WA 98033 1' - 0" MIN. WRAP POSTS WITH 1/2" GYPSUM BOARD EAST UNIT 5 GARAGE ENVELOPE DETAIL 1" = NTS DRAWING NAME: DETAILS Drawn By: US Checked By: EB Owner Approval: PHASE: PERMIT SET This drawing is the exclusive property of medici architects, and can be reproduced only with the permission of the architect. variations and modifications to work shown on this drawing shall not be carried out without written permission from the architect. APPROVED FOR CONSTRUCTION: NOTE: FLASHING TO PROECT WATERPROOF DECK FROM COLUMN PENETRATION. LAP WEATHER RESISTIVE BARRIER (NOT SHOWN) OVER SADDLE FLASHING 5/8" DIA X 5 1/2" LEG SCREWS TO BE COUNTERSUNK UNDERNEATH PROJECT No.: 2014052 DATE/ TIME: 6 ON DEMAND WATER HEATER 1" = 1'-0" 7 BOOT FLASHING @ POLE 3" = 1'-0" 8 3/10/2015 2:30:55 PM A6.0 SADDLE FLASHING 3" = 1'-0" PLOT SCALE: 1:1 MEDICI ARCHITECTS Architecture Programming Accessible Design Interior Design ® ® Breathable Membrane Systems for Roofs & Walls NOTE: USE VAPROSPRAY ADHESIVE TO ATTACH VAPROSHIELD AND 3-D CORNERS TO STEEL STUDS. Breathable Membrane Systems for Roofs & Walls INSTALL VAPROSHIELD 3-D PRE-FORMED CORNERS @ SILL. ATTACH WITH STAPLES OR AS REQUIRES BY BUILDING TYPE. INSTALL 3" VAPROTAPE OVERLAP OF PRE-FORMED VAPROSHIELD CORNERS. 9" INSTALL SILLSAVER PAN, CORNERAND SPACERS @ 6" O.C. TO SILL OF ROUGH OPENING.(MIN.) City of Kirkland Reviewed by R Braun 03/11/2015 NOTE: ALWAYS INSTALL SHINGLE FASHION 9" 11661 SE1st Street, Suite 200 Bellevue, Washington 98005 Tel: (425) 453-9298 Fax: (425) 452-8448 9" INSTALL VAPROFLASHING @ SILL DO NOT ATTACH LOWER 6" EDGE @ THIS STEP. ATTACH WITHN STAPLES OR AS REQUIRED BY BUILDING TYPE. VAPROSHIELD LLC 915 26TH AVE. N.W. SUITE C5 GIG HARBOR, WASHINGTON 98335 TOLL FREE: (866) 731-7663 FAX: (253) 858-3297 www.vaproshield.com 9" MIN. 9" 18" STEP 1 OF 10. PROTECT WALL ASSEMBLY FROM MOISTURE. STEP 2 OF 10. NOTE: USE VAPROSPRAY ADHESIVE TO ATTACH VAPROSHIELD & 3-D CORNERS TO STEEL STUDS. NOTE: LAP JAMB FLASHING OVER END DAMS OF SILLSAVER PAN. INSTALL VAPROSHIELD 3-D CORNERS @ HEAD. ATTACH WITH STAPLES OR AS REQUIRED BY BUILDING TYPE. INSTALL VAPROSHIELD @ JAMBS. ATTACH WITH STAPLES OR AS REQUIRED BY BUILDING TYPE. STEP 3 OF 10. NOTE: USE VAPROSPRAY ADHESIVE TO ATTACH VAPROSHIELD & 3-D CORNERS TO STEEL STUDS. REGISTRATION: INSTALL VAPROFLASHING @ HEAD. FOLD INTO ROUGH OPENING & ATTACH TO INTERIOR FRAMING. CUT INSIDE EDGES OF PREFORMEDCORNERS TO ALIGN WITH JAMB &HEAD FLASHING. DETAIL 1-1 TYPICAL OVERLAP MINIMUM 3" CENTER SECTION REGISTERED ARCHITECT 6926 EMILY D. BUCHWALTER NOTE: FOR AIR BARRIER DESIGN, USE WRAPSHIELD WITH VAPROTAPE @ ALL MEMBRANE JOINTS. (HORIZONTAL AND VERTICAL) STEP 4 OF 10. NOTE: FOR AIR BARRIER DESIGN, USE WRAPSHIELD WITH VAPROTAPE @ ALL MEMBRANE JOINTS (HORIZONTAL AND VERTICAL). NOTE: SOME WINDOW MFG'S REQUIRE CONTINUOUS SUPPORT @ SILL. STEP 5 OF 10. NOTE: INSTALL & SECURE WINDOW IN ACCORDANCE WITH WINDOW MFG'S RECOMMENDATIONS. ADD A CONTINUOUS SEALANT BEAD @ THE BACK OF THE SILLSAVER PAN AND ALONG THE PAN/END DAM CONNECTIONS. STATE OF WASHINGTON LEFT STEP 6 OF 10. MIN. 28 GA. PRE-FINISHED METAL HEAD FLASHING WITH FOLDED END DAMS. (BY OTHERS). SEAL WINDOW NAILING FLANGE TO VAPROFLASHING WITH SINGLE-SIDED 3" VAPROTAPE ALONG HEAD AND JAMBS ONLY. ROLL TO ACTIVATE ADHESIVE. PVC CEMENT FOR WRAPSHIELD AIR BARRIER DESIGN, SEAL LEG OF METAL HEAD FLASHING WITH SINGLESIDED VAPROTAPE TO VAPROFLASHING HEAD FLASHING. DETAIL 1-2 STEP 7 OF 10. STEP 8 OF 10. 2% 4" MIN. STEP 9a OF 10. 1" VERTICALLY INSTALLED WRAPSHIELD SA MATERIAL CAN BE INSTALLED LEFT-TO-RIGHT OR RIGHT-TO-LEFT. VARIES DETAIL 1-3 STEP 9b OF 10. REVISION 1 2-11-2015 REVISION 2 3-10-2015 TERRI BELLA RESIDENCES LOT 9 6" MIN. OVERLAP TYPICAL METAL HEAD FLASHING WITH FOLDED END DAMS, (BY OTHERS). 1. 2. 3. 4. 5. PROJECT / CLIENT: SEAL FIELD MEMBRANE WITH VAPROTAPE OVER JAMB FLASHING. SL OP EM IN. 1" VA RI ES SUB-FLOOR RIM JOIST OR SLAB NOTE: UPPER WALLSHIELD / WRAPSHIELD FIELD MEMBRANE MUST LAP OVER LOWER MEMBRANES, SHINGLE FASHION. INSTALLATION OF WALLSHIELD / WRAPSHIELD LAP 6" @ HORIZONTAL JOINTS & 12" @ VERTICAL END JOINTS. FOLD METAL BACK ONITSELF TO FORM ENDDAM WITHOUT PINHOLE. NOTE: FOR AIR BARRIER DESIGN, USE WRAPSHIELD WITH VAPROTAPE @ ALL MEMBRANE JOINTS (HORIZONTAL AND VERTICAL). DATE: REVISIONS: RIGHT SLIP WRAPSHIELD / WALLSHIELD FIELD MEMBRANE UNDER VAPROFLASING & SILL. NOTE: ALL WINDOW MATERIALS MUST BE COMPATIBLE WITH VAPRO PRODUCTS. Issue Date INTAKE DATE: NOTE: FOR AIR BARRIER DESIGN, USE WRAPSHIELD WITH VAPROTAPE @ ALL MEMBRANE JOINTS (HORIZONTAL AND VERTICAL). 335 PARKPLACE CENTER G119 KIRKLAND, WA 98033 STEP 10 OF 10. JOB ADDRESS: NOTES: 328 4TH AVE S KIRKLAND, WA 98033 NOTES: 1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 2. ALL DIMENSIONS ARE CONSIDERED TRUE AND REFLECT MANUFACTURER'S SPECIFICATIONS. 3. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info REFERENCE NUMBER 4110-200k. 1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 2. ALL DIMENSIONS ARE CONSIDERED TRUE AND REFLECT MANUFACTURER'S SPECIFICATIONS. 3. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info WEATHER SHIELD @ WINDOW DETAIL 1 1" = NTS EAST UNIT REFERENCE NUMBER 4110-222. WEATHER SHIELD DETAIL 2 1" = NTS DRAWING NAME: SILL WEATHERPROOFING DETAIL 3 1" = NTS DETAILS SHEATING PER STRUCTURE (0.975") (0.100") (11.063") W 0' - 4 3/16". I.D. MIN. FLANGE CONCEALED 6" JOINT COVER PHASE: QUICKFLASH PART # E-SGB-A 7/8 5/26/06 1/1 SCALE (2.250") QUICKFLASH PART # P-50 5/26/06 1/1 SCALE (0.875") FACE PER PLANS (11.063") (11.063") (3.500") 1/2". (11.063") PERMIT SET CONTIN. 24 GA. ANCHOR CLEAT This drawing is the exclusive property of medici architects, and can be reproduced only with the permission of the architect. variations and modifications to work shown on this drawing shall not be carried out without written permission from the architect. APPROVED FOR CONSTRUCTION: SECONDARY FASTENER SIZE B-700 & LARGER 0.388" 1. SLIDE QUICKFLASH PANEL ONTO PIPE FIRMLY PRESSING PANEL AGAINST THE WALL STUDS 2. USING NON-CORROSIVE FASTENERS, SECURE THE QUICKFLASH PANEL TO THE STRUCTURE FROM THE MIDPOINT OF THE PANEL TO THE TOP. 3. SLIDE THE WEATHER RESISTANT BARRIER UNDERNEATH THE QUICKFLASH PANEL TO THE BOTTOM OF THE PIPE. 4. INSTALL THE WEATHER RESISTANT BARRIER CAREFULLY CUTTING OPENING AROUND PIPE, OVER THE TOP OF QUICKFLASH PANEL USING SHINGLE STYLE METHOD EXTENDING TO THE BOTTOM OF FLASHING PANEL OR FURTHER. 1.SLIDE QUICKFLASH PANEL ONTO ELECTRICAL BOX FIRMLY PRESSING PANEL AGAINST THE WALL STUDS 2.USING NON-CORROSIVE FASTENERS, SECURE THE QUICKFLASH PANEL TO THE STRUCTURE FROM THE MIDPOINT OF THE PANEL TO THE TOP. 3. SLIDE THE WEATHER RESISTANT BARRIER UNDERNEATH THE QUICKFLASH PANEL TO THE BOTTOM OF THE ELECTRICAL BOX. 4. INSTALL THE WEATHER RESISTANT BARRIER CAREFULLY CUTTING OPENING AROUND ELECTRICAL BOX, OVER THE TOP OF QUICKFLASH PANEL USING SHINGLE STYLE METHOD EXTENDING TO THE BOTTOM OF FLASHING PANEL OR FURTHER. 1 X 2 STACK FASCIA BOARD OVER 1 X 6 2X PER STRUCTURE SOFFIT 1 1/2" RINF SHANK NAIL @ O.C. STAGGERED PATTERN (PROVIDED BY MFR.) EXTERIOR ELECTRICAL BOX FLASHING DETAIL 4 3" = 1'-0" Drawn By: US Checked By: EB Owner Approval: 5 PLUMBING PIPE FLASHING DETAIL 3" = 1'-0" 6 RAKE FLASHING DETAIL 6" = 1'-0" PROJECT No.: 2014052 DATE/ TIME: 3/10/2015 2:30:56 PM A6.1 PLOT SCALE: 1:1 MEDICI ARCHITECTS 4". SLOPE 15 DEGREES DOOR FASTEN ONLY @ JAMBS 4". MIN. 4". VINYL WINDOW FASTENED PER MFC RECOMMENDATIONS THERMAL BREAK AIR BARRIER SEALANT 24 GA. GALV. SHEET METAL W/ ALL OPEN SEAMS TO BE SOLDERED WALLSHIELD/ WRAPSHIELD ALUMINUM THRESHOLD VERT. 1/2" MIN. 4". UPTURN METAL END DAM (BEYOND) . 0' - 1 1/16" 4" MIN. (METAL HEAD FLASHING BY OTHERS) CCW EXTRUDED FOAM SILL WEDGE AND PERIMETER SEALED TO PAN W PURPOSE TO PROVIDE A DRAINAGE FINISH FLOORING FIG. WSP-1 TYPICAL WINDOW SILL PAN ISOMETRIC INSTALL WRAPSHIELD "U" BIB FLASHING TO NEXT JOINT IN WRAPSHIELD ASSEMBLY LAP 4" OVER METAL HEAD FLASHING AND SEAL WTIH NON-SKINNING BUTYL OR DOUBLE-SIDED VAPROTAPE City of Kirkland Reviewed by R Braun 03/11/2015 CDC APPROVED BACKER ROD & SEALANT 1/16" INTERMITTENT SHIM TO PROMOTE DRAINAGE. ATTACH TO LOWER NAIL FLANGE SEAL BEHIND NAILING FLANGE KICKBOARD DECKING SUBFLOOR PAN FLASHING FLOOR JOIST REFER TO ARCH. DWGS. FOR TYP. WALL CONST. REGISTRATION: SIDING 3 WINDOW SILL FLASHING DETAIL 6" = 1'-0" EMILY D. BUCHWALTER STATE OF WASHINGTON FLASHING AT GUTTER ROOF MEMBRANE STRIP IN .080 MILL ALUMINUM 1" WIDE STRAPS @30" O.C. OPTIONAL .250" ALUMINUM HANGER AVAILABLE FRAMING PER STRUCTURAL FRAMING PER STRUCTURAL BLOCKING BLOCKING WATERPROOF MEMBRANE ROOFING WATERPROOF MEMBRANE ROOFING 1. 2. 3. 4. 5. 0' - 1" 11 7/8" 0' - 7 1/4" HICKMAN MBEM - STYLE -B ( OR EQUAL) PREFORMED METAL FASCIA/ RAKE FLASHING WITH CONTINUOUS CLEAT. DATE: REVISIONS: SHEATHING PER STRUCTURAL PLAN HICKMAN MBEM - STYLE -B ( OR EQUAL) PREFORMED METAL FASCIA/ RAKE FLASHING WITH CONTINUOUS CLEAT. Issue Date INTAKE DATE: " 31/32 NGE F FLA ROO 0' - 3 FORMER GUTTER 10' LENGTHS 2' - 0" SHEATHING PER STRUCTURAL PLAN REGISTERED ARCHITECT 6926 VAPROSHIELD BLACK WALSHIELD WRB WINDOW & DOOR HEADER FLASHING DETAIL 2 3" = 1'-0" SILL WEATHERPROOF DETAIL 6" = 1'-0" 11661 SE1st Street, Suite 200 Bellevue, Washington 98005 Tel: (425) 453-9298 Fax: (425) 452-8448 VAPROSHIELD PENETRATION WRAP NAIL FLANGE WINDOW SET HEAD FLANGE IN A CONTINUOUS BEAD OF NON-SKINNING BUTYL SEALANT SECURE PER WINDOW MANUFACTURER'S INSTALLATION RECOMMENDATIONS NOTE: CONTRACTOR TO VERIFY ALL DIMENSIONS IN THE FIELD. MEMBRANE AND FLASHING COMPONENTS ARE NOT SHOWN TO SCALE FOR CLARITY. DECK FLASHING 24 GA. GALV. METAL SILL PAN. SEE DETAIL WSP-1 ABOVE 1/2" PT FURRING STRIPS @ 16" O.C. VAPROSHIELD EXPANDING FOAM TAPE 1 2X TRIM PER ARCH. W/ CANTED TOP EDGE TO DRAIN & SAWED KERF @ BOTTOM & NOTCH TO RECEIVE SIDING MIN. 26 GA. PRE-FINISHED METAL HEAD FLASHING OPTION: SEAL WINDOW W/VAPROSHIELD EXPANDING FOAM TAPE Architecture Programming Accessible Design Interior Design REVISION 1 2-11-2015 REVISION 2 3-10-2015 PROJECT / CLIENT: PER ARCH PLANS ROOF - UN-VENTED CAVITY - MIX INSULATION 1.625" ICYNENE CLOSED-CELL WATER-BASED SPRAY FOAM INSULATION R-4.9 PER INCH AND R-38C BATT INSULLATION - TOTAL R-45.96 (TO BE CALSS II VAPOR BARRIER) INSTALL PER MANUFACTURER, & IN ACCORDANCE WITH IRC 806.5. APPLY IN DIRECT CONTACT WITH UNDERSIDE OF STRUCTURAL SHEATHING FINISH PER ELEVATION ROOF - UN-VENTED CAVITY - MIX INSULATION 1.625" ICYNENE CLOSED-CELL WATER-BASED SPRAY FOAM INSULATION R-4.9 PER INCH AND R-38C BATT INSULLATION - TOTAL R-45.96 (TO BE CALSS II VAPOR BARRIER) INSTALL PER MANUFACTURER, & IN ACCORDANCE WITH IRC 806.5. APPLY IN DIRECT CONTACT WITH UNDERSIDE OF STRUCTURAL SHEATHING 5/8" GWB @ CEILING FINISH PER ELEVATION R-21 / 2 x 6 STUDS PER PLAN R - 10 RIGID INSULATION @ HEADERS Z FLASHING FACE BLOCKING & MECHANICAL FASTENER BY INSTALLER 0' - 6" PER ELEVATIONS PER ARCH. PLANS TERRI BELLA RESIDENCES LOT 9 335 PARKPLACE CENTER G119 KIRKLAND, WA 98033 TRIM BOARD PER OWNER 1X FASCIA BOARD PER ARCHITECTURAL PLAN CONCEALED JOINT SPLICE 6" WIDE WINDOW HEADER JOB ADDRESS: 328 4TH AVE S KIRKLAND, WA 98033 0' - 6" EAST UNIT BOTTOM 4 DETAIL AT UN-VENTED EAVE 1" = 1'-0" DETAIL AT EAVE 1" = 1'-0" 5 6 DRAWING NAME: 6" GUTTER BOX 6" = 1'-0" DETAILS 4 Drawn By: US Checked By: EB Owner Approval: PHASE: 0' - 2 1/4" ' 3' - 0" C12 PER STRUCTURAL PLAN WELDED "T" SUPPORT ABOVE WELDED "T" SUPPORT - 1-1/2" X 3/8" TO 1/1/2" X1/4" STEEL FLAT BARS PERMIT SET WELDED 3/8" SPACER This drawing is the exclusive property of medici architects, and can be reproduced only with the permission of the architect. variations and modifications to work shown on this drawing shall not be carried out without written permission from the architect. STEEL FLAT BAR @ 4'-0" O.C. (MIN.) 1' - 0" 0 3' - 0" 2X4 IPE HANDRAIL ABOVE 3' - 6 3/4" 3' - 0" (2) 2X BLOCKING AS SHOWN W/ 1/4" SDS. (GALV. SCREWS @ 6" O.C. TO DBL RIM) 2X4 IPE HANDRAIL -" 0' - 6" CERTIFIED WABO SHOP WELDED 3/8" SPACER APPROVED FOR CONSTRUCTION: 0' - 5" 0' - 5" 8 HANDRAIL SECTION & CORNER PLAN 1" = 1'-0" 1/4" PLATE W/ 5/8" X 3 1/2" LONG LAG SCREWS @ 5" O.C. AT EXPOSED DECKSEXPOSED LAYER OF FIBERGLASS MIXTURE TO INCLUDE SAND FOR UV PROTECTION AND PROVIDE SLIP RESISTANCE. FIBERGLASS WATERPROOF MEMBRANE OVER 1/2" THICK PLYWOOD OVER 3/4" PLYWOOD, PLYWOOD MUST BE ACX CROSS-PLUGGED (NO TONGUE AND GROOVE) UNDERLAYMENT, PLYWOOD SUBSTRATE SHOULD BE INSTALLED JUST PRIOR TO FIBERGLASS LAMINATION PROCESS, PLYWOOD MUST NOT BE ALLOWED TO ABSORB ANY MOISTURE WHAT SO EVER. 0' - 1 1/2" 0' - 3" 0' - 1 1/2" 0' -0'5"- 1 1/2" 0' - 2" AT DECKSFIBERGLASS WATERPROOF MEMBRANE OVER 1/2 " THICK MARINE PLYWOOD OVER 3/4 " PLYWOOD, PLYWOOD MUST BE ACX CROSS-PLUGGED (NO TONGUE AND GROOVE) UNDERLAYMENT, PLYWOOD SUBSTRATE SHOULD BE INSTALLED JUST PRIOR TO FIBERGLASS LAMINATION PROCESS, PLYWOOD MUST NOT BE ALLOWED TO ABSORB ANY MOISTURE WHAT SO EVER. 0' - 2" 0' - 2" 0' - 11 1/4" min. min. 0' - 8" 2" 2X @ 16"o.c. W/ SIMPSON A35 FRAMING CLIP TO DBL RIM. CABLING SYSTEM - VERIFY DIA. FOR UPRIGHT THROUGH-HOLES TYP. (4" LONG MIN.) 1/4" PLATE W/ 5/8" X 3 1/2" LONG LAG SCREWS @ 5" O.C. 0' - 1" 1/8 0' - 8" 1/4" OPEN GRID CEDAR DECK BOARD SLOPE 1/4" PER 12" DECK WATERPROOFING DETAIL 1" = 1'-0" HANDRAIL UPRIGHT SPACING PER ARCHITECTURAL PLANS 8D @ 4" O.C. HARDIE BOARD SOFFITSOFFIT 7 0' - 3 1/2" NOTCH 2X TO FORM TRENCH. FLASHING & WRAP WITH WATER PROOF MEMBRANE 5" FIBERGLASS WATERPROOF MEMBRANE PER R905.15.2 (IRC 2012) OVER 1/2" THICK MARINE PLYWOOD OVER 3/4" PLYWOOD - SLOPE 1/4" PER 12" 0' - 5 11/32" 1' - 0" AT EXPOSED DECKSEXPOSED LAYER OF FIBERGLASS MIXTURE TO INCLUDE SAND FOR UV PROTECTION AND PROVIDE SLIP RESISTANCE. FIBERGLASS WATERPROOF MEMBRANE PER IRC R905.15.(2) - The installation of liquid-applied roofing shall comply with the provisions of this section) OVER 1/2" THICK PLYWOOD OVER 3/4" PLYWOOD, PLYWOOD MUST BE ACX CROSS-PLUGGED (NO TONGUE AND GROOVE) UNDERLAYMENT, PLYWOOD SUBSTRATE SHOULD BE INSTALLED JUST PRIOR TO FIBERGLASS LAMINATION PROCESS, PLYWOOD MUST NOT BE ALLOWED TO ABSORB ANY MOISTURE WHAT SO EVER. 0' - 1 1/4" AT DECKSFIBERGLASS WATERPROOF MEMBRANE PER IRC R905.15.(2) -The installation of liquid-applied roofing shall comply with the provisions of this section) OVER 1/2 " THICK MARINE PLYWOOD OVER 3/4 " PLYWOOD, PLYWOOD MUST BE ACX CROSS-PLUGGED (NO TONGUE AND GROOVE) UNDERLAYMENT, PLYWOOD SUBSTRATE SHOULD BE INSTALLED JUST PRIOR TO FIBERGLASS LAMINATION PROCESS, PLYWOOD MUST NOT BE ALLOWED TO ABSORB ANY MOISTURE WHAT SO EVER. 5" x 3/8" STEEL FLAT BAR WELDED TO C12 2" x 1/2" STEEL FLAT BARS 0' - 5" 0' - 1 1/2" 1/8 TYP. (4" LONG MIN.) PROJECT No.: 2014052 DATE/ TIME: 9 3/10/2015 2:30:57 PM A6.2 HANDRAIL ELEVATION 1" = 1'-0" PLOT SCALE: 1:1 INTERIOR SHEATHING ARTISAN R LAP WATER RESISTIVE BARRIER (HARDIE WRAP OR EQUIVALENT) WOOD FRAMING 3' - 0" INSULATION WHERE REQ'D (2) 2X BLOCKING AS SHOWN W/ 1/4" SDS. (GALV. SCREWS @ 6" O.C. TO DBL RIM) INTERIOR SHEATHING WATER RESISTIVE BARRIER (HARDIE WRAP OR EQUIVALENT) MOISTURE BARRIER 1/4" PLATE W/ 5/8" X 3 1/2" LONG LAG SCREWS @ 5" O.C. APRON FLASHING (OPTIONAL) MIN. 6" 1' - 0" 0' - 8" STARTER STRIP 0' - 2" CONCRETE FOOTING GRADE CLEARANCE 2X @ 16"o.c. W/ SIMPSON A35 FRAMING CLIP TO DBL RIM. min. min. 2" 5" SLOPE 1/4" PER 12" OVERLAP TYP. (4" LONG MIN.) EXTERIOR SHEATHING MIN. 1 1/4" 1/8 Architecture Programming Accessible Design Interior Design ARTISAN R LAP WOOD FRAMING 1/4" OPEN GRID CEDAR DECK BOARD HARDIE BOARD SOFFITSOFFIT BOTTOM PLATE EXTERIOR SHEATHING MIN. 1 1/4" OVERLAP 1" DIA STEEL ROD PER STRUCTURAL MEDICI ARCHITECTS INSULATION WHERE REQ'D City of Kirkland Reviewed by R Braun 03/11/2015 11661 SE1st Street, Suite 200 Bellevue, Washington 98005 Tel: (425) 453-9298 Fax: (425) 452-8448 PATH / DRIVEWAY / SLAB REGISTRATION: 0' - 5" STEEL BEAM PER STRUCTURAL REGISTERED ARCHITECT 6926 1 DETAIL AT OPEN GRID DECK 1" = 1'-0" 2 GRADE CLEARANCE @ HARDIE SIDING 3" = 1'-0" 3 TYP. LAP SIDING 3" = 1'-0" EMILY D. BUCHWALTER STATE OF WASHINGTON NOTE: REFER TO WINDOW MANUFACTURER'S INSTRUCTIONS FOR PROPER WINDOW INSTALATION INSULATIONS AS REQ. WOOD FRAMING PER STRUCTURE PLANS Issue Date INTAKE DATE: HARDIE LAP SIDING INSULATIONS AS REQ. WATER RESISTIVE BARRIER (HARDIE WRAP OR EQUIVALENT) WOOD FRAMING PER STRUCTURE PLANS EXTERIOR SHEATHING PER STRUCTURE PLANS WINDOW FRAME FLASH WINDOW PER MANUFACTURER RECOMMENDATION (IF TRIM IS PROTRUDING BEYOND WINDOW SILL IT MUST BE FLASHED.) 0' - 3" WATER RESISTIVE BARRIER (HARDIE WRAP OR EQUIVALENT) INSULATIONS AS REQ. EXTERIOR SHEATHING PER STRUCTURE PLANS WOOD FRAMING PER STRUCTURE PLANS HARDIE TRIM BOARD HARDIE LAP SIDING LEAVE APPROPRIATE GAP AND CAULK S.A.F. MEMBRANE NOTE: 3/8" MIN. GAP IS RECOMMENDED TO ACCOUNT FOR STRUCTURAL MOVEMENT BETWEEN FLOOR JOINTS. 1/4" MIN. CLEARANCE IS REQUIRED BETWEEN PANEL HORIZONTALS IN DIRECT TO APPLICATIONS. OVERLAP MIN. 1 1/4" Z FLASHING 1. 2. 3. 4. 5. REVISION 1 2-11-2015 REVISION 2 3-10-2015 PROJECT / CLIENT: TERRI BELLA RESIDENCES LOT 9 LAP SIDING 3/8" GAP MIN., DO NOT CAULK DATE: REVISIONS: WATER RESISTIVE BARRIER (HARDIE WRAP OR EQUIVALENT) 1/4" GAP MIN., DO NOT CAULK HEADER 335 PARKPLACE CENTER G119 KIRKLAND, WA 98033 Z - FLASHING HARDIE TRIM BOARD JOB ADDRESS: NOTE: EVERY OTHER FLOOR BREAK SHALL HAVE Z-FLASHING EXTENDING BACK TO THE WEATHER BARRIER. EXTERIOR SHEATHING PER STRUCTURE PLANS HORIZONTAL BREAK @ FLOOR TRANSITION @ HARDIE LAP 4 3" = 1'-0" 328 4TH AVE S KIRKLAND, WA 98033 WINDOW FRAME NOTE: REFER TO WINDOW MANUFACTURER'S INSTRUCTIONS FOR PROPER WINDOW INSTALATION WINDOW SILL @ HARDIE LAP SIDING 5 3" = 1'-0" EAST UNIT DRAWING NAME: WINDOW/ DOOR HEAD @ HARDIE LAP 6 3" = 1'-0" DETAILS NORSTONE ROCK PANELS (CHARCOAL) Drawn By: US Checked By: EB Owner Approval: CEDAR TIGHT KNOT LAP SIDING WITH 4" EXPOSURE - SEAL AND STAIN ALL SIDES BEFORE INTALLING @ ALL CUTS POLYMER MODIFIED THINSET INTERIOR SHEATHING WATER RESISTIVE BARRIER (HARDIE WRAP OR EQUIVALENT) CEMENT BOARD PHASE: WOOD FRAMING ANTI FRACTURE WATER PROOFING MEMBRANE PERMIT SET INSULATION WHERE REQ'D SHEATING EXTERIOR SHEATHING PER STRUCTURE PLANS FLASHING TAPE WOOD FRAMING PER STRUCTURE PLANS INSULATIONS AS REQ. This drawing is the exclusive property of medici architects, and can be reproduced only with the permission of the architect. variations and modifications to work shown on this drawing shall not be carried out without written permission from the architect. BOTTOM PLATE DOOR / WINDOW JAMB MOISTURE BARRIER LAP BUILDING PAPER OVER FLASHING & SCREED APPROVED FOR CONSTRUCTION: CRAWL SPACE METAL FLASHING, SEAL TO FOUNDATION 0' - 2" CONCRETE SLAB / MASONRY FOOTING 0' - 8" 0' - 2 1/2" MIN. 6" GRADE CLEARANCE APRON FLASHING LEAVE APPROPRIATE GAP AND CAULK PATH / DRIVEWAY / SLAB CEDAR TIGHT KNOT LAP SIDING WITH 4" EXPOSURE - SEAL AND STAIN ALL SIDES BEFORE INTALLING @ ALL CUTS WATER RESISTIVE BARRIER (HARDIE WRAP OR EQUIVALENT) PROJECT No.: 2014052 DATE/ TIME: 7 DETAIL AT NORSTONE STONE VENEER 3" = 1'-0" 8 GRADE CLEARANCE @ SIDING (TYP.) 3" = 1'-0" 9 3/10/2015 2:30:58 PM A6.3 DOOR / WINDOW JAMB @ CEDAR SIDING 3" = 1'-0" PLOT SCALE: 1:1 NOTE: REFER TO WINDOW MANUFACTURER'S INSTRUCTIONS FOR PROPER WINDOW INSTALATION HARDIE PANEL SIDING CEDAR TIGHT KNOT LAP SIDING WITH 4" EXPOSURE - SEAL AND STAIN ALL SIDES BEFORE INTALLING @ ALL CUTS INSULATIONS AS REQ. 1/4" GAP MIN., DO NOT CAULK BLOCKING AS REQ'D Z - FLASHING HARDIE TRIM BOARD City of Kirkland Reviewed by R Braun 03/11/2015 TRIM AROUND OPENING S.A.F. MEMBRANE LEAVE APPROPRIATE GAP AND CAULK WOOD FRAMING PER STRUCTURE PLANS Architecture Programming Accessible Design Interior Design EXTERIOR SHEATHING PER STRUCTURE PLANS EXTERIOR SHEATHING PER STRUCTURE PLANS WOOD FRAMING PER STRUCTURE PLANS FLASH WINDOW PER MANUFACTURER RECOMMENDATION (IF TRIM IS PROTRUDING BEYOND WINDOW SILL IT MUST BE FLASHED.) WATER RESISTIVE BARRIER (HARDIE WRAP OR EQUIVALENT) WATER RESISTIVE BARRIER (HARDIE WRAP OR EQUIVALENT) WINDOW FRAME INSULATIONS AS REQ. MEDICI ARCHITECTS VENT OPENING 1/4" GAP MIN., DO NOT CAULK WATER RESISTIVE BARRIER (HARDIE WRAP OR EQUIVALENT) HEADER Z - FLASHING HARDIE TRIM BOARD CEDAR TIGHT KNOT LAP SIDING WITH 4" EXPOSURE - SEAL AND STAIN ALL SIDES BEFORE INTALLING @ ALL CUTS 11661 SE1st Street, Suite 200 Bellevue, Washington 98005 Tel: (425) 453-9298 Fax: (425) 452-8448 WOOD RAINSCREEN FURRING AROUND FIXTURE INSTALL BUG SCREEN AS NECESSARY LEAVE APPROPRIATE GAP AND CAULK WINDOW FRAME EXTERIOR SHEATHING PER STRUCTURE PLANS REGISTRATION: NOTE: REFER TO WINDOW MANUFACTURER'S INSTRUCTIONS FOR PROPER WINDOW INSTALLATION REGISTERED ARCHITECT 6926 WINDOW SILL @ CEDAR SIDING 3" = 1'-0" 1 2 FIXTURE PENETRATION @ HARDIE PANELS OR CEDAR 3 3" = 1'-0" WINDOW/ DOOR HEAD @ CEDAR SIDING 3" = 1'-0" EMILY D. BUCHWALTER STATE OF WASHINGTON R311.7.5.1 RISERS: THE MAXIMUM RISER HEIGHT SHALL BE 73/4 INCHES. OPEN RISERS ARE PERMITTED PROVIDED THAT THE OPENING BETWEEN TREADS DOES NOT PERMIT THE PASSAGE OF A 4-INCH-DIAMETER (102 MM) SPHERE. BELOW STAIR INSTALL 5/8" TYPE 'X' G.W.B. (2) LAYERS @ CEILING, (1) LAYER @ WALLS A STAIR NOSING PROFILE PER PER IRC R311.7.4.3 B 2-11-2015 REVISION 2 3-10-2015 TERRI BELLA RESIDENCES LOT 9 INTERIOR SHEATHING INSULATION WHERE REQ'D 335 PARKPLACE CENTER G119 KIRKLAND, WA 98033 WATER RESISTIVE BARRIER (HARDIE WRAP OR EQUIVALENT) WOOD FRAMING JOB ADDRESS: 328 4TH AVE S KIRKLAND, WA 98033 ARTISAN R LAP NOTE: GREATEST AND LEAST TREAD & RISER SHALL NOT VARY MORE THAN 3/8" (PER IRC R311.7.4.1 & R311.7.4.2) INTERIOR STEEL STAIR DETAIL 4 1/2" = 1'-0" REVISION 1 PROJECT / CLIENT: BLOCKING @ MIDSPAN 36" MIN. STAIRWAY WIDTH PER IRC R311.7.1 1. 2. 3. 4. 5. ARTISAN R LAP MITERED CORNER STAIR NOSING PROFILE PER IRC R311.7.4.3 (3) 2X12 STRINGERS NOTE: GREATEST AND LEAST TREAD & RISER SHALL NOT VARY MORE THAN 3/8" (PER IRC R311.7.4.1 & R311.7.4.2) ABOVE NOSING RUN 10" MIN. 7 3/4" MAX 7 3/4" MAX 4" MAX SIMPSON U212 HANGER, PER STRUCTURE STEEL ANGLE L 3X2X1/4 UNDER TREAD 10" LENGTH @ EACH SIDE OF TREAD STEEL C CHANNEL SIDE RAILS C12 X 20.7 36" MIN. STAIRWAY WIDTH PER IRC R311.7.1 6'-8" MIN. HEADROOM MIN. BELOW STAIR INSTALL 5/8" TYPE 'X' G.W.B. (2) LAYERS @ CEILING, (1) LAYER @ WALLS 8" MI N. MAX. 4" ABOVE NOSING 0" 2'10" MIN. / 3'2" MAX. 0' - 11" HANDRAILS PER IRC R311.7.7 BALUSTERS TO CONFORM TO IRC R312.3 DATE: REVISIONS: METAL CORNER FLASHING (3) 8d TOE NAIL STRINGER TO THRUST BLOCK 4X12" WOOD SLAB STAIR TREAD 1' 6'8" MIN. HEADROOM A SUB FLOOR PER STRUCTURAL PLAN SHEET S3 Issue Date INTAKE DATE: WOOD FRAMING (HANDRAIL GRIP SIZE PER IRC R311.7.7.3) 1 1/4" DIA. MIN. HANDRAIL, CONT. FOR FULL LENGTH OF STAIR NOTE: SPACING BETWEEN INTERMEDIATE GUARDRAIL MEMBERS TO BE SUCH THAT A SPHERE OF 4 3/8" SHALL NOT PASS THROUGH ANY OPENING THE TRIANGULAR OPENINGS AT THE SIDES OF A STAIR, FORMED BY THE RISER AND BOTTOM OF THE GUARD RAIL, SHALL NOT ALLOW PASSAGE OF A SPHERE 6" IN DIAMETER. 2' - 11 31/32" 3' - 0" B (HANDRAIL GRIP SIZE PER IRC R311.7.7.3) 1 1/4" DIA. MIN. HANDRAIL, CONT. FOR FULL LENGTH OF STAIR MIN. CABLE GUARD RAIL 2'-10" MIN. /32" MAX. NOTE: GUARDS ON THE OPEN SIDES OF STAIRS SHALL NOT HAVE OPENING WHICH ALLOWS PASSAGE OF A SPHERE 4 3/8" IN DIAMETER. RISER R311.7.5.1 RISERS: THE MAXIMUM RISER HEIGHT SHALL BE 73/4 INCHES. OPEN RISERS ARE PERMITTED PROVIDED THAT THE OPENING BETWEEN TREADS DOES NOT PERMIT THE PASSAGE OF A 4-INCH-DIAMETER (102 MM) SPHERE. EAST UNIT EXTERIOR SHEATHING 3'-0" MIN. INTERIOR WOOD FRAMED STAIR DETAIL 5 3/4" = 1'-0" DRAWING NAME: INSIDE CORNER - MITERED LAP SIDING 6 3" = 1'-0" DETAILS BLOCKING PER STRUCTURAL DRAWINGS Drawn By: US Checked By: EB Owner Approval: PLATE 1/4"x4"x8" w/ 2-1/2" x4" LAGS INTO CORNER POST, SEE DETAIL 7/S2.6 PHASE: 5" ARTISAN R LAP PERMIT SET TENSION BAR/ROD PER STRUCTURAL DRAWINGS INSULATION WHERE REQ'D This drawing is the exclusive property of medici architects, and can be reproduced only with the permission of the architect. variations and modifications to work shown on this drawing shall not be carried out without written permission from the architect. EXTERIOR SHEATHING INTERIOR SHEATHING SPECIFYING ENGINEER IS RESPONSIBLE FOR CONCRETE ENCASEMENT AND REINFORCING BASED UPON APPLICATION AND LOCAL CODES FLASHING WOOD FRAMING WATER RESISTIVE BARRIER (HARDIE WRAP OR EQUIVALENT) 4" DRAIN DOWNSPOUT WATERPROOF MEMBRANE OVER 5/8" APA RATED SHTG SLOPE 1/4" PER 12" FASCIA AS SHOW TO HIDE SLOPE APPROVED FOR CONSTRUCTION: 2X PER STRUCTURAL PLANS 1 4 6_ [159] 2 X CONT LEDGER PER STRUCTURAL PLANS 4 [102] MIN. HARDIE BOARD SOFFIT 4"DOWNSPOUT ARTISAN R WITH METAL CORNER FLASHING AT LAP MITERED CORNER PLATE 1/4"x4"x6" w/ 4SDS 1/4" X 3" PER STRUCTURAL ARTISAN R LAP OUTSIDE CORNER - MITERED LAP SIDING 7 3" = 1'-0" 8 DETAIL AT CANOPY 1 1/2" = 1'-0" PER ARCHITECTURAL PLANS 4 [102] INVERT min. 2" 1/4"X8" PLATE W 4-SDS 1/4" X 3" SCREWS TO 4X BEAM PER STRUCTURAL 1 4 1_ [32] 1 4 81 _ [2064] 4 [102] MIN. 80 [2032] 'A' 'B' NOTE: + Actual Channel length is 81 1/4 [2064] to allow for overlap. TRENCH DRAIN TIGHTLINE CONNECTION TO STORM WATER SYSTEM METAL FASCIA, C8 PER STRUCTURAL 2x8 RIPPED TO TAPER @ 1/4" PER 12" @ 16"O.C. W/ SIMPSON FRAMING CLIP EA END PER STRUCTURAL PLANS PROJECT No.: 2014052 DATE/ TIME: 9 3/10/2015 2:31:00 PM A6.4 DETAIL AT TRENCH DRAIN SYSTEM 3/4" = 1'-0" PLOT SCALE: 1:1 MEDICI ARCHITECTS Architecture Programming Accessible Design Interior Design City of Kirkland Reviewed by R Braun 03/11/2015 11661 SE1st Street, Suite 200 Bellevue, Washington 98005 Tel: (425) 453-9298 Fax: (425) 452-8448 REGISTRATION: REGISTERED ARCHITECT 6926 DETAIL AT TILE-LINED SHOWER RECEPTORS 1 1" = 1'-0" EMILY D. BUCHWALTER STATE OF WASHINGTON Issue Date INTAKE DATE: DATE: REVISIONS: 1. 2. 3. 4. 5. REVISION 1 2-11-2015 REVISION 2 3-10-2015 PROJECT / CLIENT: TERRI BELLA RESIDENCES LOT 9 335 PARKPLACE CENTER G119 KIRKLAND, WA 98033 JOB ADDRESS: 328 4TH AVE S KIRKLAND, WA 98033 DRAWING NAME: DETAILS Drawn By: US Checked By: EB Owner Approval: PHASE: PERMIT SET This drawing is the exclusive property of medici architects, and can be reproduced only with the permission of the architect. variations and modifications to work shown on this drawing shall not be carried out without written permission from the architect. APPROVED FOR CONSTRUCTION: PROJECT No.: 2014052 DATE/ TIME: 3/10/2015 2:31:00 PM A6.5 PLOT SCALE: 1:1 TERRI BELLA RESIDENCES 332 4TH AVE KRIKLAND, WA 98033 2. 3. DESCRIPTION Building Name & Site Location - TERRI BELLA WEST, MIDDLE, EAST/LOT 8 Building Dept. Contact - CITY OF KIRKLAND DESIGN CODE AND STANDARDS Applicable Code (Edition/Name) - 2012 International Building Code (IBC) Other documents referenced by these notes shall be the specific edition referenced by the building code specified above, or if not specified, shall be the latest edition. Code supplement & Date - ASCE 7-10 DESIGN LOADS I. Roof Live Load II. Floor Live Load a. Snow Load See snow load 40 psf Basic ground snow load - Pg = NA Basic roof snow load - Pf = 25 psf Thermal factor - Ct = 1.0 Importance factor - Is = 1.0, Snow exposure factor - Ce = 1.0 Drifting snow (is/is not) required in the design. b. Seismic c. Wind Load 1 d. Dead loads e.Load Combinations SDS = 0.842, SD1 = 0.490, S1 = 0.486 Basic Seismic Force Resisting System = Bearing Wall System Light-framed walls sheathed with wood structural panels rated for shear resistance LAT = 47.6727 LON = 122.2015 R = 6.50 Equivalent Lateral Force Procedure used. Basic wind speed (3 sec. gust) = 110 (mph) Exposure C Importance factor Iw = 1.0. Topographic factor Kzt = 1.0 Internal pressure coefficient GCpi - + 0.18 Components & cladding = 21 psf Weight of structure. All Code required load combinations are to be used in the building design. OSHA STANDARDS THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PROVISIONS OF THE CURRENT OSHA STANDARDS. THE GENERAL CONTRACTOR SHALL REVIEW THESE STRUCTURAL DRAWINGS FOR ANY NONCOMPLIANCE WITH OSHA STANDARDS, TAKING INTO ACCOUNT THE GENERAL CONTRACTOR'S MEANS AND METHODS. THE GENERAL CONTRACTOR SHALL INFORM ENW OF ANY NONCOMPLIANCE SO THE DRAWINGS MAY BE MODIFIED FOR COMPLIANCE PRIOR TO CONSTRUCTION. THE GENERAL CONTRACTOR IS TOTALLY RESPONSIBLE FOR MEANS AND METHODS AS WELL AS JOBSITE SAFETY ON THIS PROJECT. FOUNDATION ASSUMED ALLOWABLE SOIL BEARING CAPACITY OF 2000 PSF. EXTEND ALL EXTERIOR FOOTING NATIVE SOILS OR ON STRUCTURAL FILL COMPACTED TO 95% MODIFIED PROCTOR - ASTM D-1557 OR ON UNDISTURBED SOIL. C:\Users\BHARATP\appdata\local\temp\AcPublish_9396\Terri Bella - East Unit - 48.dwg, 03-10-15, 7:12am, BHARATP, 48 SLABS ON GRADE THE SLAB ON GRADE FOR THIS PROJECT IS TYPICAL OF THAT IN OTHER BUILDINGS WITH SIMILAR FLOOR LOADINGS AND SOIL CONDITIONS. THE SLAB HAS NOT BEEN DESIGNED FOR ANY SPECIFIC LIVE LOAD (INCLUDING CONSTRUCTION LOADS) AND HAS BEEN DETAILED TO MEET LOCAL INDUSTRY STANDARDS FOR SIMILAR BUILDINGS. REVIEW WITH THE SOILS ENGINEER ANY CONSTRUCTION LOADINGS ON THE SLAB AND SOILS BELOW. TAKE NECESSARY MEASURES TO INSURE THAT THE SLAB AND SOILS BELOW WILL NOT BE EFFECTED OR DAMAGED BY THE CONSTRUCTION LOADING. CONCRETE PROVIDE 28-DAY STRENGTH PER SCHEDULE. FOR SPECIAL CONDITIONS ANOTHER TYPE MAY BE REQUIRED. SUBMIT FOR APPROVAL. ULTIMATE STRENGTH DESIGN METHOD USED. MIXING AND PLACING OF ALL CONCRETE AND SELECTION OF MATERIALS SHALL BE IN ACCORDANCE WITH THE ACI CODE 318. PROPORTIONING OF AGGREGATE TO CEMENT SHALL BE SUCH AS TO PRODUCE A DENSE WORKABLE MIX WITH 4" MAXIMUM SLUMP (UNLESS SUPERPLASTICIZERS AND WATER REDUCING AGENTS ARE USED) WHICH CAN BE PLACED WITHOUT SEGREGATION OR EXCESS FREE SURFACE WATER. FOR ADMIXTURES, SEE SPECIFICATIONS. 3/4" CHAMFER ALL EXPOSED EDGES, UNLESS INDICATED OTHERWISE ON ARCHITECTURAL DRAWINGS. WATER CURING SHALL BE USED. AIR ENTRAIN ALL CONCRETE EXPOSED TO WEATHER PER SCHEDULE. LIMIT WATER TO CEMENT RATIO PER SCHEDULE. ADD NO WATER TO CONCRETE AT SITE. IF INCREASED WORKABILITY IS REQUIRED, CONTRACTOR IS TO SUBMIT A MIX DESIGN THAT WILL ALLOW THE ADDITION OF A FIXED AMOUNT WATER REDUCING AGENT OR A FIXED AMOUNT OF SUPER-PLASTICIZER AT THE CONCRETE PLANT. ACI 306R IS TO BE FOLLOWED FOR COLD WEATHER CONCRETING. ACI 305R IS TO BE FOLLOWED FOR HOT WEATHER CONCRETING. THE TESTING LAB MUST APPROVE THE CONTRACTORS METHOD OF COMPLIANCE AND CERTIFY THEIR APPROVAL WITH EACH CONCRETE TEST CYLINDER THEY CAST. TESTING LAB TO NOTIFY THE ARCHITECT AND ENGINEER IMMEDIATELY OF ANY NONCOMPLIANCE. REINFORCING STEEL USE DEFORMED CONCRETE REINFORCING STEEL CONFORMING WITH ASTM A 615, GRADE 60 (fy=60,000 PSI). LAP CONTINUOUS REINFORCING BARS 48 BAR DIAMETERS, 2'-0" MIN. UNLESS NOTED DETAIL STEEL IN ACCORDANCE WITH "ACI MANUAL OF STANDARD PRACTICE OF DETAILING REINFORCED CONCRETE STRUCTURES". WELDED WIRE FABRIC (WWF) TO CONFORM WITH ASTM A 185. REINFORCING HOOKS TO COMPLY WITH STANDARD ACI HOOKS EXCEPT STIRRUPS AND TIES SHALL HAVE 135 DEGREE ACI SEISMIC HOOKS. COVER TO REINFORCEMENT: NONPRESTRESSED CAST-IN-PLACE CONCRETE (INCHES) FORMED SURFACES NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND SLABS, WALLS, JOISTS..........................14 AND LARGER.......................................1-1/2 #11 AND SMALLER......................................3/4 LOW HYDROGEN ELECTRODES CONFORMING TO ANSI/AWS A5.1 OR A5.5. DO NOT WELD REINFORCING IF TEMPERATURE IS BELOW 32 DEGREES FAHRENHEIT. MAINTAIN A MINIMUM PREHEAT AND INTERPASS TEMPERATURE OF 50 DEGREES FAHRENHEIT FOR NO. 7 THROUGH NO. 11 BARS. DO NOT WELD NO. 14 AND NO. 18 BARS. DO NOT WELD WITHIN 3-INCHES OF BENDS. LET BARS COOL NATURALLY TO AMBIENT TEMPERATURE AFTER WELDING; DO NOT QUENCH. USE WABO CERTIFIED WELDERS. PROVIDE SPECIAL INSPECTION PER CODE. SUBMIT MILL CERTIFICATES. REBAR DOWEL INSTALLATION DRILL HOLES FOR DOWELS IN ACCORDANCE WITH GROUT MANUFACTURERS RECOMMENDATIONS. BLOW HOLE CLEAN WITH OIL FREE COMPRESSED AIR. FILL HOLES WITH A MEASURED AMOUNT OF HILTI HIT-RE 500-SD. INSERT REBAR AND SECURE UNTIL GROUT HAS REACHED ITS INITIAL CURE. ALL WORK SHALL BE BY PERSONNEL EXPERIENCED IN THE USE OF THIS PRODUCT, AND IN ACCORDANCE WITH ICC REPORT NO ESR-2322. FRAMING LUMBER LUMBER S4S AND S-DRY UNLESS NOTED OTHERWISE. UNLESS NOTED OTHERWISE, USE THE FOLLOWING: SPECIES GRADE BASE VALUE Fb #2 #2 #1 #1 #2 #2 550 PSI 900 PSI 1000 PSI 900 PSI 900 PSI 900 PSI DOUG FIR #1 1350 PSI DOUG FIR #1 1200 PSI VISUALLY GRADED DIMENSION LUMBER STUDS - TYPICAL STUDS - WHERE NOTED JOISTS & RAFTERS - TYPICAL JOISTS & RAFTERS - WHERE NOTED PLATES & LEDGERS BEAMS & HEADERS - TYPICAL DOUG FIR DOUG FIR DOUG FIR DOUG FIR DOUG FIR DOUG FIR STRUCTURAL STEEL 1. STRUCTURAL STEEL DESIGN, FABRICATION, ERECTION SHALL BE BASED ON THE LATEST EDITIONS OF THE A.I.S.C. SPECIFICATIONS AND CODES: a) b) VISUALLY GRADED TIMBERS BEAMS & STRINGERS 2. POSTS & TIMBERS EACH PIECE SHALL BEAR A VALID GRADE STAMP THAT IS NOT TO BE REMOVED. BOLT HEADS AND NUTS BEARING AGAINST WOOD SHALL BE PROVIDED WITH STANDARD CUT WASHERS. ALL BASE VALUE STRESSES TO BE ADJUSTED WITH APPROPRIATE SIZE FACTORS. ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESERVATIVE TREATED. USE STANDARD LENGTH COMMON NAILS CONFORMING WITH FEDERAL SPECIFICATION FF-N-105B FOR ALL NAILING EXCEPT WHERE SHORTER NAILS PROVIDE THE REQUIRED PENETRATION IN DIAPHRAGMS. PROVIDE MIN. NAILING PER IBC TABLE 2304.9.1 UNLESS NOTED OTHERWISE. ALL HANGERS, TIES AND CONNECTORS ARE SIMPSON. OTHER MANUFACTURERS WITH ICC-ES APPROVED LOAD CAPACITIES EQUAL TO OR GREATER THAN THAT SPECIFIED MAY BE USED. NAIL ALL HOLES WITH NAILS AS SPECIFIED BY MANUFACTURER. CUT NO HOLES IN ANY STRUCTURAL FRAMING WITHOUT ENGINEERS APPROVAL, EXCEPT THAT 1-INCH DIAMETER HOLES MAY BE DRILLED IN 2X STUDS AND PLATES --NO MORE THAN ONE HOLE EVERY 6-INCHES. ALL FASTENERS, CONNECTORS AND ANCHORS IN CONTACT WITH PRESSURE TREATED WOOD SHALL BE STAINLESS STEEL, ZMAX (G185 HDG PER ASTM A653), HOT-DIP GALVANIZED (HDG) PER ASTM A123 FOR CONNECTORS AND ASTM A153 FOR FASTENERS, OR MECHANICALLY GALVANIZED FASTENERS PER ASTM B695, CLASS 55 OR GREATER. GLU-LAMINATED WOOD MEMBERS GLU-LAMINATED WOOD BEAMS, COAST REGION DOUGLAS FIR CONFORMING WITH ANSI/AITC A190.1-02 AND AITC 117 OF APA-EWS Y117. USE COMBINATION EWS24F-V4 (DF/DF) Fb=2400, Fvx = 190 PSI FOR SIMPLE SPAN BEAMS AND COMBINATION EWS24F-V8 (DF/DF) Fb=2400, Fvx = 190 PSI FOR CANTILEVERED BEAMS. BOTTOM LAM TO BE FREE OF UNSOUND KNOTS LARGER THAN 1/2" DIAMETER. MATERIAL MUST BE OBTAINED FROM AN APPROVED FABRICATOR. ALL GLU-LAM BEAMS SHALL FIT SNUG AND TIGHT IN THEIR CONNECTIONS AND DEVELOP FULL BEARING AS INDICATED. PROVIDE AITC OR APA-EWS STAMP ON EACH MEMBER AND SUBMIT AITC OR APA-EWS CERTIFICATE. ADHESIVE TO BE "WET USE". INDUSTRIAL APPEARANCE GRADE. WOOD STRUCTURAL PANELS CONFORM WITH P.S. 1-09 OR P.S. 2-10. ALL PANELS RATED EXPOSURE 1. SEE PLANS FOR NAILING SPACING. ROOF SHEATHING: COMMON NAILS WITH 1-5/8" MINIMUM PENETRATION. PROVIDE PLYWOOD SHEATHING CLIPS ON UNSUPPORTED EDGES MIDWAY BETWEEN FRAMING MEMBERS. SPACE NAILS AT 6" ON CENTER AT ALL EDGES AND 12" ON CENTER FIELD NAILING (BLOCK UNSUPPORTED EDGES WITH 2X FLAT) UNLESS NOTED OTHERWISE ON PLANS OR DIAPHRAGM SCHEDULE. WALL SHEATHING: COMMON NAILS WITH 1-5/8" MINIMUM PENETRATION. SPACE NAILS AT 6" ON CENTER AT ALL EDGES AND 12" ON CENTER FIELD NAILING (BLOCK UNSUPPORTED EDGES WITH 2X FLAT) UNLESS NOTED OTHERWISE ON PLANS OR DIAPHRAGM SCHEDULE. FLOOR SHEATHING: DIAMETER X 3") RINGSHANK NAILS WITH 1-5/8" MINIMUM PENETRATION. GLUE PLYWOOD TO SUPPORTS AND AT T & G JOINTS WITH ADHESIVE CONFORMING TO APA SPECIFICATION AFG-01. SPACE NAILS AT 6" ON CENTER AT ALL EDGES AND 10" ON CENTER FIELD NAILING (BLOCK UNSUPPORTED EDGES WITH 2X FLAT) UNLESS NOTED OTHERWISE ON PLANS OR DIAPHRAGM SCHEDULE. 3. 4. SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS- ALLOWABLE STRESS DESIGN. SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS. STRUCTURAL STEEL, INCLUDING PLATES AND ROLLED SHAPES, SHALL CONFORM TO ASTM A36, FY = 36 KSI. STEEL PIPES SHALL CONFORM TO ASTM A-53, TYPE E OR S, GRADE B, FY =35 KSI. STRUCTURAL TUBING SHALL CONFORM TO ASTM A500, GRADE B, FY = 46 KSI. ANCHOR BOLTS AND CONNECTION BOLTS SHALL CONFORM TO ASTM A307. ALL WELDING SHALL BE IN CONFORMANCE WITH A.I.S.C. AND A.W.S. STANDARDS AND SHALL BE PERFORMED BY W.A.B.O. CERTIFIED WELDERS USING E70 XX ELECTRODES. ONLY PRE-QUALIFIED WELDS (AS DEFINED BY A.W.S.) SHALL BE USED. ANCHOR BOLTS SHALL CONFORM TO ASTM A307 AND HAVE A WELDED HEAD. EMBED ANCHOR BOLTS A MINIMUM OF 7" INTO CONCRETE OR MASONRY. CONNECTION BOLTS AND THREADED STUDS SHALL CONFORM TO ASTM A307. SPECIAL CONDITIONS CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND SHALL PROVIDE ADEQUATE SHORING AND BRACING OF ALL STRUCTURAL MEMBERS DURING CONSTRUCTION. CONTRACTOR SHALL NOTIFY ENGINEER OF ALL FIELD CHANGES PRIOR TO INSTALLATION. OTHER INSPECTIONS BY BUILDING OFFICIAL IN ACCORDANCE WITH SECTION 109 OF IBC. ABBREVIATIONS AB, A.B. ABV. ADD'L ADJ. ALT. APPRX. ARCH @ BOT. BF, B.F. BEL. BLDG BLKG BN, B.N. BNDRY BM B.O. BRDG BRG B/W CAM ANCHOR BOLT ABOVE ADDITIONAL ADJACENT ALTERNATE APPROXIMATE ARCHITECTURAL AT BOTTOM BRACED FRAME BELOW BUILDING BLOCKING BOUNDARY NAIL BOUNDARY BEAM BOTTOM OF BRIDGE (ING) BEARING BETWEEN CAMBER(ED) CANTILEVER(ED) CG CENTER OF GRAVITY CIP CAST IN PLACE CJ, C.J. CONTRACTUAL JOINT CL CENTER LINE CLR CLEAR CMU CONC. MASONRY UNIT COL. COLUMN CONC. CONCRETE CONN. CONNECT(ION) CONST. CONSTRUCTION CONT. CONTINUOUS CTSK COUNTERSINK d PENNY (NAILS) DET. DETAIL DBL DOUBLE DF, D.F. DOUGLAS FIR DIA. DIAMETER DIAG. DIAGONAL DIAPH. DIAPHRAGM do DITTO (DO OVER) D DEPTH DWG DRAWING DWL DOWEL (E) EXISTING MEMBER EA. EACH EF, E.F. EACH FACE EJ, E.J. EXPANSION JOINT EMBED. EMBEDMENT EL, ELEV. ELEVATION EN, E.N. EDGE NAIL ENG ENGINEER EQ EQUAL ES, E.S. EACH SIDE EXIST EXISTING EXT. EXTERIOR FFE FINISH FLOOR ELEV. FAB. FABRICATION FND FOUNDATION FIN. FINISH(ED) FLG FLANGE FLR FLOOR FN, F.N. FACE NAIL FO, F.O. FACE OF FRM'G FRAMING FS, F.S. FAR SIDE FTG FOOTING GA GAGE GALV. GALVANIZED GB, G.B. GRADE BEAM GLB GLU-LAM. BEAM GRD GRADE GWB GYPSUM WALL BOARD HDR HEADER HF, H.F. HEM-FIR HGR HANGER HORZ. HORIZONTAL HSB HIGH STRENGTH BOLT (A325 UNO) HT HEIGHT IF, I.F. INSIDE FACE INT. INTERIOR JST JOIST JT K LAT. LDGR LF LLH LLV LS LSL LT WT LVL MAS. MAT'L MB MD MRF MFR MTL (N) NS, N.S. NTS OC, O.C. OF, O.F. OH OPN'G ORNT PAR P/C PERP. PL PLYWD PSL PT, P.T. P/T QTY REF. REINF. REQ'D RO, R.O. SCHD SHT SHTG SIM. SKW SOG SPC SQ. SS STD STGR STIFF. STIR. STL STRUC. SYM. T T&G THR'D TJ TMPRY TN, T.N. T.A. TRANS. TYP. UNO VERT. VFY W/ WHS WP WS WTS WWF X-STG XX-STG JOINT KIPS (1,000 POUNDS) LATERAL LEDGER LINEAL FEET LONG LEG HORIZ. LONG LEG VERTICAL LAG SCREW TIMBER STRAND BEAM LIGHT WEIGHT MICROLLAM BEAM MASONRY MATERIAL MACHINE BOLT (A307) MID-DEPTH MOMENT RESISTING FRAME MANUFACTURER METAL NEW MEMBER NEAR SIDE NOT TO SCALE ON CENTER OUTSIDE FACE OVER HANG OPENING ORIANTATE(ION) PARALLEL PRECAST CONCRETE PERPENDICULAR PLATE PLYWOOD PARALLAM BEAM PRESSURE TREATED POST TENSIONED QUANTITY REFERENCE REINFORCEMENT REQUIRED ROUGH OPENING SCHEDULE SHEET SHEATHING SIMILAR SKEW(ED) SLAB ON GRADE SPACING SQUARE SELECT STRUCTURAL STANDARD STAGGER STIFFENER STIRRUP STEEL STRUCTURE(AL) SYMMETRICAL TOP TONGUE AND GROOVE THREAD(ED) TRUSS JOIST MACMILLAN TEMPORARY TOE NAIL TOP OF TRANSVERSE TYPICAL UNLESS OTHERWISE NOTED VERTICAL VERIFY WITH WELDED HEADED STUD WORK POINT WESTERN SERIES WELDED THREADED STUD WELDED WIRE FABRIC EXTRA STRONG DOUBLE EXTRA STRONG 332 4TH AVE KIRKLAND, WA 98033 1. REINFORCING STEEL WELDING USE ASTM A 706 GRADE 60 (fy = 60000 PSI) FOR ANY REINFORCING THAT IS TO BE WELDED. FOLLOW CONCRETE AND MASONRY ANCHORS (BOLTS, THREADED RODS) DRILLED IN EXPANSION ANCHORS: CONCRETE HILTI KWIK BOLT TZ PER ESR-1917 POWERS POWER-STUD+ SD2 PER ESR-2502 SIMPSON STRONG-BOLT 2 PER ESR-3037 CONCRETE MASONRY HILTI KWIK BOLT 3 PER ESR-1385 POWERS POWER-STUD+ SD1 PER ESR-2966 SIMPSON WEDGE-ALL PER ESR-1396 ADHESIVE ANCHORS: CONCRETE HILTI HIT-RE 500-SD PER ESR-2322 POWERS PE1000+ PER ESR-2583 SIMPSON SET-XP PER ESR-2508 CONCRETE MASONRY HILTI HIT HY 150 MAX PER ESR-1967 SIMPSON SET PER ESR-1772 SCREW ANCHORS: CONCRETE HILTI KWIK HUS-EZ (KH-EZ) PER ESR-3027 POWERS WEDGE-BOLT+ PER ESR-2526 SIMPSON TITEN HD PER ESR-2713 CONCRETE MASONRY POWERS WEDGE-BOLT+ PER ESR-1678 SIMPSON TITEN HD PER ESR-1056 CAST-IN-PLACE BOLTS - (UNLESS NOTED OTHERWISE) CONCRETE - EMBED PER IBC TABLE 1911.2 MASONRY - EMBED 7 BOLT DIAMETERS. PROVIDE 1/2 INCH OF GROUT BETWEEN BOLT AND MASONRY. FOLLOW INSTALLATION PROCEDURES OF ESR REPORT PROVIDE SPECIAL INSPECTION AS NOTED OR REQUIRED BY ESR REPORT. TERRI BELLA RESIDENCES THE FOLLOWING NOTES APPLY UNLESS NOTED OTHERWISE - ASTM'S NOTED ARE TO BE LATEST EDITION. BEAMS, COLUMNS PRIMARY REINFORCEMENT, TIES, STIRRUPS,SPIRALS..........................................1-1/2 GENERAL NOTES GENERAL NOTES 18530 Meridian AVE North Shoreline, WA 98133 206-779-6850 City of Kirkland Reviewed by R Braun 03/11/2015 REVISIONS: 1 03-10-15 CADD FILE: 15012 DATE: 01-25-15 DRAWN: B. PATEL CHECKED: C. BURT S0.0 1 3 2 5 4 6 1 3 2 30'-0" 8'-0" 3'-4" 5 4 6 30'-0" 9'-7" 9 1/2" 8'-3 1/2" 8'-0" 3'-4" 9'-7" 9 1/2" 8'-3 1/2" 1 N U 1 LD 1 D O W H D O N W D 18530 Meridian AVE North Shoreline, WA 98133 206-779-6850 W N O 9'-2 1/2" O LD D 5 U D H H O LD D 5 O W N H U D H N W O LD D 5 U D W4 H H N W O LD 6'-8" 45'-4 1/2" W4 8E 1. L PS 1/ 2 M 4'-5" N 3 LU 2'-3 1/2" LEGEND: J/S2.1 J/S2.1 4" CONCRETE SLAB ON GRADE w/ W1.4xW1.4 6x6 WELDED WIRE REINFORCING AT MID-DEPTH. VAPOR BARRIER AND SUBGRADE BY OTHERS J/S2.1 STRUCTURAL WALL STRUCTURAL WALL BELOW Wx Wx PLYWOOD SHEAR WALL SIMPSON SSTB20 ANCHOR TO SPAN DIRECTION OF JOISTS ALIGN W/HOLD DOWN ABOVE 8'-3 1/2" 8'-0" 13'-8 1/2" 8'-3 1/2" SPAN DIRECTION OF JOISTS WOOD BEAM PER PLAN STRUCTURAL WALL 30'-0" 5'-9 1/2" N M OPP./S2.1 PLYWOOD SHEAR WALL 13'-8 1/2" O W ST H D/S2.2 O STRUCTURAL WALL BELOW WOOD POST PER DETAILS SSTB D 5 LD 14 D RJ O W N J H LEGEND: CONCRETE STEM WALL LD O H O AB O N 2x 1/ 3 4" CONCRETE SLAB ON GRADE w/ W1.4xW1.4 6x6 WELDED WIRE REINF. AT MID-DEPTH. VAPOR BARRIER AND SUBGRADE BY OTHERS D M/S2.1 M OPP./S2.1 H I F/S2.1 J F2.0 WALL PER 8" CONCRETE WALL PER U D H 6'-8 1/2" 6'-8 1/2" J J/S2.1 G 6'-8 1/2" I L/S2.1 B/S2.2 I 2x12 @ 16"oc CONC. SHEAR WALL PANEL w M BS J D/S2.2 O C H L/S2.1 / H F B/S2.1 CONC. SHEAR WALL PANEL G LU .4 x Q 4C 44 O FA 1 S.J. 2'-3 1/2" G N FA C 1'-6" CONT. FOOTING P. T 6'-8 1/2" REINF. PER C/S2.1 LU . H 4" CONCRETE SLAB ON GRADE w/ W1.4xW1.4 6x6 WELDED WIRE REINFORCING AT MID-DEPTH. VAPOR BARRIER AND SUBGRADE BY OTHERS M 4'-5" 4'-5" 3 F3.0 8" CONCRETE WALL w/ S S. 1 VE 3 2x 1/ C 8E 1. F 16 3/ x 2 1/ 3 VE x 2 1/ BO 3 A S. MN . .S LU H O C S.J. 6 /1 x3 /2 .3 L/S2.1 B/S2.2 5'-9 1/2" 5'-9 1/2" H/S2.2 SL F 2'-3 1/2" L/S2.1 E/S2.1 FOUNDATION AND FIRST FLOOR FRAMING PLANS -EAST- 4'-1 1/2" K-2.1 E TERRI BELLA RESIDENCES -EAST UNIT- O D LD H O H D U 5 W N 2x12 @ 16"oc W N O E C/S2.1 C 1/2 O x LU 3 1 M /2 N P LU . 3 M 1/2 N AB x3 1 O /2x VE 3 /1 6 H C O O .S .S A SIM./S2.1 8'-0" D CRAWL SPACE ACCESS K/S2.1 D LD O H H O H H W4 D U D 5 O K/S2.1 LD D U 5 W N 1 K-2.1 4'-1 1/2" 45'-4 1/2" 45'-4 1/2" 4'-1 1/2" PER ARCH., TYP. FOUNDATION VENTS 4 4x P. T. D E D 11 U D LD H H A/S2.1 ST E/S2.1 D C O N W D O 11 U D H H LD W4 1 O J 6'-8" 6'-8" 4 O H D /P B4 ST H D 14 R N W O 1 PO 4 4x T. P. 1'-6" CONT. FOOTING /1 6 REINF. PER C/S2.1 8" CONCRETE WALL w/ D/S2.1 .S .S LU . 3 M 1/2 N AB x3 1 O /2x VE 3 D/S2.1 A/S2.1 C 332 4TH AVE KIRKLAND, WA 98033 H ST D D/S2.1 J 14 R N W O w 4 B4 /P w ST PO F2.0 E/S2.1 C H N O 9'-2 1/2" 9'-2 1/2" D D/S2.1 D/S2.1 H/S2.2 .F D B/S2.1 8" CONCRETE W 2x12 @ 16"oc 1'-6" CONT. FOOTING REINF. PER C/S2.1 8" CONCRETE WALL w/ 1'-6" CONT. FOOTING REINF. PER C/S2.1 8" CONCRETE WALL w/ 9'-2 1/2" 6'-8" 4'-1 1/2" 5'-9 1/2" 4'-5" 2'-3 1/2" O N 45'-4 1/2" D W6 I C:\Users\BHARATP\appdata\local\temp\AcPublish_9396\Terri Bella - East Unit - 48.dwg, 03-10-15, 7:13am, BHARATP, 48 O W 11 DO LD U 11 LD D H O H LD B A/S2.1 U D O H K/S2.1 F2.0 M/S2.1 N 4 4x 1 H W 11 DO LD 2 .# K/S2.1 F3.5 U 4 4x .F D E G H F/S2.1 1'-6" CONT. FOOTING C 2 .# F D REINF. PER C/S2.1 N 8" CONCRETE WALL w/ A/S2.1 A/S2.1 O W D H O D F/S2.2 LD A/S2.1 C O 1'-6" CONT. FOOTING U 11 H 8" CONCRETE WALL w/ N H D O W B H O H H B A/S2.1 D D 4'-8 1/2" U 5 O LD H 4'-8 1/2" 4'-8 1/2" B/S2.1 4'-8 1/2" LD 11 O U D H 2W4 B REINF. PER C/S2.1 H H/S2.2 City of Kirkland Reviewed by R Braun A 03/11/2015 H H D U 1 O LD 1 D O W N N D U 1 O LD 1 D O W H N A 2W4 H A H A H H D U 1 O LD 1 D O W B/S2.1 4" CONCRETE SLAB ON GRADE w/ W1.4xW1.4 6x6 WELDED WIRE REINFORCING AT MID-DEPTH. VAPOR BARRIER AND SUBGRADE BY OTHERS J/S2.1 H/S2.2 B/S2.1 F/S2.2 REINF. PER C/S2.1 8" CONCRETE WALL w/ PER ARCH., TYP. 1'-6" CONT. FOOTING FOUNDATION VENTS 30'-0" HD SIMPSON HOLD DOWN ANCHOR WOOD BEAM PER PLAN REVISIONS: 1 2 1 4 5 6 FOUNDATION PLAN 1/4" = 1'-0" NOTES: 1.) SLAB ON GRADE SHALL BE 4" THICK, UNLESS OTHERWISE NOTED. SLAB SHALL BE REINFORCED WITH 6x6 W1.4-W1.4 WELDED WIRE MESH. PREPARE SUBGRADE BY PLACING AND COMPACTING A MINIMUM 4" OF CLEANED, CRUSHED ROCK AS A CAPILLARY BREAK. SUBGRADE BELOW SLAB SHALL BE UNDISTURBED NATIVE SOIL OR COMPACTED FILL PER PLAN NOTE 2. 2.) FOOTINGS SHALL BE PLACED ON UNDISTURBED NATIVE SOIL OR STRUCTURAL FILL COMPACTED TO 95% MAXIMUM WET DENSITY PLACED IN MAX. 12" LIFTS. 3.) SEE S2.1 FOR TYPICAL SPREAD FOOTING INFORMATION, AND S2.1 FOR TYPICAL CONTINUOUS FOOTING INFORMATION. 4.) TYPICAL FLOOR JOISTS SHALL BE 2x12 DF-L#1 OR BETTER UNLESS OTHERWISED NOTED. REFER TO PLAN FOR JOIST SPACING (16"oc IF NOT NOTED). 5.) BEAMS AT THIS LEVEL SHALL BE LSL 3-1/2" x 11-7/8" 1.55E UNLESS OTHERWISE NOTED. 6.) VENEER TIES TO BE SPACED AT MAXIMUM 24"oc HORIZONTAL AND VERTICAL. USE ONLY ICC-ES APPROVED MASONRY ANCHORS FOR ALL STONE OR MASONRY VENEER INSTALLED 8'-0" ABOVE GRADE. 7.) TYPICAL EXTERIOR WALL W6, U.N.O. PER SHEAR WALL SCHEDULE ON S2.3. FOOTING SCHEDULE MARK F2.0 SIZE 2'-0"x2'-0"x10" 1 F3.0 3'-0"x3'-0"x12" 4- #4 EACH WAY BOTTOM F3.5 3'-6"x3'-6"x14" 4- #4 EACH WAY BOTTOM FA 2'-6"x4'-0"x12" 4- #4 EACH WAY BOTTOM NOTES: 1.) VERIFY MINIMUM 2000psf BEARING CAPACITY w/ GEOTECH PRIOR TO CASTING FOOTINGS. 2.) CENTER ALL FOOTINGS ON COLUMN AND WALL TYPICAL, U.N.O. 3.) AT LOCATONS WHERE FOOTINGS ARE SHOWN SHARING A COMMON BEARING AREA, CST MONOLITHICALLY w/ INDIVIDUAL REINFORCING PER SCHEDULE & OVERLAP AS REQUIRED. 4 5 6 FLUSH OR DROP HEADER PER PLAN NOTE 5. HD SIMPSON HOLD DOWN ANCHOR 1 REINFORCEMENT 3- #4 EACH WAY BOTTOM 2 HDR 2 FIRST FLOOR FRAMING PLAN 1/4" = 1'-0" NOTES: 1.) TYPICAL FLOOR FRAMING CONSISTS OF 3/4" T&G PLYWOOD ON SAWN JOISTS. NAIL ALL SUPPORTED PANEL EDGES WITH 10d NAILS @ 6"oc & ALL INTERMEDIATE SUPPORTS WITH 10d NAILS @ 12"oc. 2.) TYPICAL FLOOR JOISTS SHALL BE 2x12 DF-L #1 JOISTS UNLESS OTHERWISE NOTED. REFER TO PLAN FOR JOIST SPACING (16"oc IF NOT NOTED). 3.) BEAMS AT THIS LEVEL SHALL BE GL 3 1/8" x 12 1/2" U.N.O. UNLESS OTHERWISE NOTED. 4.) TYPICAL EXTERIOR WALL SHALL BE FRAMED WITH 2x6 DF STUDS @ 16"oc, UNLESS OTHERWISE NOTED. TYPICAL INTERIOR WALLS SHALL BE FRAMED WITH 2x4 DF STUDS @ 16"oc UNLESS OTHERWISE NOTED. REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION PERTAINING TO WALL THICKNESSES. 5.) TYPICAL EXTERIOR WALL HEADERS SHALL BE FRAMED WITH (3) PLIES OF 2x10 DF #2, UNLESS OTHERWISE NOTED 6.) ALL EXTERIOR WALLS TO BE SHEATHED WITH 1/2" EXTERIOR PLYWOOD OR 7/16" EXTERIOR RATED OSB. INTERMEDIATE STUDS. IF HORIZONTAL PANEL JOINT DOES NOT FALL ON A FRAMING MEMBER, PROVIDE 2x4 FLAT BLOCKING BEHIND AND FASTEN AS NOTED ABOVE. 7.) TYPICAL EXTERIOR WALL W6, U.N.O. PER SHEAR WALL SCHEDULE ON S2.3. 03-10-15 WOOD POST STEEL POST CADD FILE: 15012 DATE: 01-25-15 DRAWN: B. PATEL CHECKED: C. BURT S1.1E 3 5 4 6 1 3 2 4 R ST S1 6 C W4 C 6 9'-2 1/2" AP ST R 6 S1 W N O D 2W6 ST R S1 C NOTE: BLOCK UNDER ALL CANTILEVERS THIS LEVEL J LEGEND: 3 STRUCTURAL WALL STRUCTURAL WALL BELOW INTERMEDIATE STUDS. IF HORIZONTAL PANEL JOINT DOES NOT FALL ON A FRAMING MEMBER, PROVIDE 2x4 FLAT BLOCKING BEHIND AND FASTEN AS NOTED ABOVE. 7.) TYPICAL EXTERIOR WALL W6, U.N.O. PER SHEAR WALL SCHEDULE ON S2.3. 48 U H PLYWOOD SHEAR WALL 30'-0" 48 U C 4x8 D.F. #1 2x8 D.F.#1 1/2" PLYWOOD SHEATHING STRONG AXIS PERPENDICULAR 2x LEDGER w/ 3- SDS 1/4"x3 @ 16"oc H U C 48 B 3 1 2 4 5 6 WOOD BEAM PER PLAN HDR FLUSH OR DROP HEADER PER PLAN NOTE 5. HD SIMPSON HOLD DOWN ANCHOR 2- 2x8 HEADER 2x8 D.F.#1 1/4" = 1'-0" NOTES: 1.) TYPICAL FLOOR FRAMING CONSISTS OF 3/4" T&G PLYWOOD ON SAWN JOISTS. NAIL ALL SUPPORTED PANEL EDGES WITH 10d NAILS @ 6"oc & ALL INTERMEDIATE SUPPORTS WITH 10d NAILS @ 12"oc. 2.) TYPICAL FLOOR JOISTS SHALL BE 2x12 DF-L #1 JOISTS UNLESS OTHERWISE NOTED. REFER TO PLAN FOR JOIST SPACING (16"oc IF NOT NOTED). 3.) BEAMS AT THIS LEVEL SHALL BE GL 3 1/8" x 9" U.N.O. UNLESS OTHERWISE NOTED. 4.) TYPICAL EXTERIOR WALL SHALL BE FRAMED WITH 2x6 DF STUDS @ 16"oc, UNLESS OTHERWISE NOTED. TYPICAL INTERIOR WALLS SHALL BE FRAMED WITH 2x4 DF STUDS @ 16"oc UNLESS OTHERWISE NOTED. REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION PERTAINING TO WALL THICKNESSES. 5.) TYPICAL EXTERIOR WALL HEADERS SHALL BE FRAMED WITH (3) PLIES OF 2x10 DF #2, UNLESS OTHERWISE NOTED 6.) ALL EXTERIOR WALLS TO BE SHEATHED WITH 1/2" EXTERIOR PLYWOOD OR 7/16" EXTERIOR RATED OSB. Wx REVISIONS: H 2'-0" 4'-8 1/2" 6 SECOND FLOOR FRAMING PLAN 8'-3 1/2" SPAN DIRECTION OF JOISTS 2'-0" 5 13'-8 1/2" 4x8 D.F. #1 A 4 8'-0" C w/ CLEVIS EACH END F/S2.6 8'-3 1/2" TERRI BELLA RESIDENCES -EAST UNIT- 45'-4 1/2" H SECOND AND THIRD FLOOR FRAMING PLANS -EAST- S1 6 6 ST ST R C O C CS16 STRAP PER F/S2.5 @ GRID J AP PLATE 1/4"x3"x4" 30'-0" 1 6'-8" 2'-3 1/2" N 1/ 1/ M 2 C 6 3/S1.3E S1 LD PLATE 1/4"x4"x6" w/ 4- SDS 1/4"x3" D/S2.4 TYP. @ HD OVER BEAM 13'-8 1/2" 2 G 6'-8 1/2" 4 x5 L PS 3'-4" 1 5'-9 1/2" 4'-5" N M LU O C 3 1/2x10 1/2 G.L.B. TYPICAL 2x12 D.F.#1 @ 16"oc G/S2.6 I A/S2.3 AP R AP N W O J 2 8'-0" 4'-1 1/2" C C 2- 2x10 S1 6 ST R AP E/S2.6 E/S2.6 HDR. 1/ 1/ 3 1/8x9 GLB J 18530 Meridian AVE North Shoreline, WA 98133 206-779-6850 AP ST R 6 S1 C 2x 6 PI PE N M O LU 3" X XS SL 2x 3 M 1/2 N P 1/ LU O 3 C 2- 2x8 R AP ST 6 C S1 6'-8 1/2" 6'-8 1/2" W10x15 3 D 5 U x5 2 3 G/S2.6 D LD O N 4 HDR. H LD 1/ 2 1/ UM L 3 O C O W 2'-3 1/2" I C 2x12 D.F.#1 @ 16"oc 2- 2x8 5'-9 1/2" 4'-5" 4'-5" I TYPICAL 4'-1 1/2" 45'-4 1/2" 45'-4 1/2" 4'-1 1/2" 5'-9 1/2" N W O 2'-3 1/2" H N H 4 x5 F L PS LU O W U H 5 O LD D O LD O 5 U D G L PS O W N O H D B/S2.3 N G O H O D 5 U D 3- 3 1/8x9 G.L.B. LD O H N W O D LD F E H H D N W N D 5 U D LD A/S2.5 H O H O W N W O D 5 U F D AP LD 3 1/8x9 G.L.B. AP R ST O 2x 6 R 6 H 3- ST S1 D E C C H H TYPICAL 3 1/2x9 G.L.B. PE R F O O PR E A/S2.4 B/S2.3 ST M OPP./S2.1 K/S2.5 D PO 2W4 M/S2.1 OPEN FOR STAIR/LANDING 4 W10x22 J H N D 2 U D H O W N W O D 2 U H O H LD D R ST 6 S1 C 6'-8" HDR. 4x N N HDR. N W W W O H 2x12 D.F.#1 @ 16"oc C H .) G AR IN BE AR D 5 U D H H ST PO 4x 4 AP ST S1 6 C EE L ST ED N 1/ O 2x5 LU M 1/4 N 1 AB .8E O VE O R D O VE LD LI O D D 5 H 5 U D U LD C H D O LD H 5 O S1 6 W6 E SIM./S2.4 3 5 1/8x9 G.L.B. CANTILEVER H H O U IN LD 2- 2x10 D H N W O D LD O H E/S2.6 E/S2.6 U C D 6'-8 1/2" H O PE PI M N S XX C TYPICAL D H x R x4 4 TE . A .S (W .S E H T A PL D O 3" VE 8E O AB 1. 4 1/ O LU M N x5 1/ 2 3 C 5 H LINE OF STRUCTURE ABOVE 16 3/ H W4 R 2'-3 1/2" A/S2.3 6'-8" LD 2x12 D.F.#1 @ 16"oc 5'-9 1/2" 4'-5" 16 3/ x 2 1/ 3 VE x 2 1/ BO 3 A S. MN . .S LU H O C E OPP./S2.4 AP B/S2.3 I C:\Users\BHARATP\appdata\local\temp\AcPublish_9396\Terri Bella - East Unit - 48.dwg, 03-10-15, 7:13am, BHARATP, 48 5 U x6 D LD O H H U O 2 U LD D D W4 C 1 LU 4'-1 1/2" 45'-4 1/2" 32 W16x31 H 2- 2x10 D HDR. H D 6 2x C 6 S1 AP W O 11 U D O H LD AP W6 R ST W4 C HDR. N W 6 S1 C AP R H O ST S1 ST 6 C 2 D R AP AP B S1 H N N W O D 11 U D O H H H 5 3- F N B/S2.3 C W O 6'-8" D M/S2.5 6 S1 W4 U 5 1/2x10 1/2 G.L.B. E 5 LD AP K/S2.5 R ST C U D OPEN FOR STAIR/LANDING D G C H 1 O 6 S1 W4 H C R ST 1 C S1 HDR. B/S2.3 W4 C 4'-8 1/2" S ST R AP C 6 S1 C 9'-2 1/2" 9'-2 1/2" N O W D LD O HDR. H S 6 O W D O 5 U D AP R T 2- 2x8 LD D H TYPICAL ST 48 M ST AP 5 U H 6 S1 B N AP R AP R ST 48 M ST R ST 2x12 D.F.#1 @ 16"oc C 6 S1 AP S S1 C W4 2- 2x10 6 S1 9'-2 1/2" C R ST 6 AP R T 2x12 D.F.#1 @ 16"oc B HDR. HDR. 2- 2x8 4'-8 1/2" 4'-8 1/2" B City of Kirkland Reviewed by R Braun A 03/11/2015 HDR. ACROSS C TO D C S1 S1 6 6 ST ST R R AP AP W B/S2.3 AP R T R 2W4 HDR. A O D LD O H HDR. HDR. AP ST R M ST 48 ST R H AP 48 5 U D R M ST ST 2W4 CS16 STRAP GRID 1 TO 3 48 4'-8 1/2" ST M AP N A 8'-3 1/2" AP AP ST C S1 6 8 T4 9 1/2" R R ST ST S M 9'-7" AP ST R 48 M ST 48 2W4 HDR. 3'-4" 2- 2x8 1 M ST 2W4 HDR. A 8'-0" ST R R M ST 48 2W4 ST A/S2.3 R ST M ST 48 3/S1.2E 8'-3 1/2" AP 9 1/2" AP 9'-7" AP 3'-4" 6 30'-0" AP 8'-0" 5 332 4TH AVE KIRKLAND, WA 98033 30'-0" A/S2.3 2 TYPICAL 1 CANOPY FRAMING PLAN 1/2" = 1'-0" 2 THIRD FLOOR FRAMING PLAN 1/4" = 1'-0" NOTES: 1.) TYPICAL FLOOR FRAMING CONSISTS OF 3/4" T&G PLYWOOD ON SAWN JOISTS. NAIL ALL SUPPORTED PANEL EDGES WITH 10d NAILS @ 6"oc & ALL INTERMEDIATE SUPPORTS WITH 10d NAILS @ 12"oc. 2.) TYPICAL FLOOR JOISTS SHALL BE 2x12 DF-L #1 JOISTS UNLESS OTHERWISE NOTED. REFER TO PLAN FOR JOIST SPACING (16"oc IF NOT NOTED). 3.) BEAMS AT THIS LEVEL SHALL BE GL 3 1/8" x 9" U.N.O. UNLESS OTHERWISE NOTED. 4.) TYPICAL EXTERIOR WALL SHALL BE FRAMED WITH 2x6 DF STUDS @ 16"oc, UNLESS OTHERWISE NOTED. TYPICAL INTERIOR WALLS SHALL BE FRAMED WITH 2x4 DF STUDS @ 16"oc UNLESS OTHERWISE NOTED. REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION PERTAINING TO WALL THICKNESSES. 5.) TYPICAL EXTERIOR WALL HEADERS SHALL BE FRAMED WITH (3) PLIES OF 2x10 DF #2, UNLESS OTHERWISE NOTED 6.) ALL EXTERIOR WALLS TO BE SHEATHED WITH 1/2" EXTERIOR PLYWOOD OR 7/16" EXTERIOR RATED OSB. INTERMEDIATE STUDS. IF HORIZONTAL PANEL JOINT DOES NOT FALL ON A FRAMING MEMBER, PROVIDE 2x4 FLAT BLOCKING BEHIND AND FASTEN AS NOTED ABOVE. 7.) TYPICAL EXTERIOR WALL W6, U.N.O. PER SHEAR WALL SCHEDULE ON S2.3. WOOD POST STEEL POST 1 03-10-15 CADD FILE: 15012 DATE: 01-25-15 DRAWN: B. PATEL CHECKED: C. BURT S1.2E 1 3 2 4 PER 5 6 30'-0" 8'-0" 3'-4" H.S.S. 4x8x3/16 PER 9'-7" 9 1/2" NOTE: NAILER NOT SHOWN 8'-3 1/2" A/S1.3E WELD STUDS @ 32"oc 9" 6" MAX. HDR. PEEN THREADS A 4'-8 1/2" 12 H.S.S. PER PLAN HDR. A ARCH. PER A/S2.6 W4 H.S.S. PER PLAN PLATE 1/4"x12"x0'-4" 4'-8 1/2" PER ARCH. A/S2.6 DOUBLE NUT WHERE OCCURS D/S2.6 PER ARCH. 1 City of Kirkland Reviewed by R Braun 03/11/2015 H.S.S TO PLATE 3/16 W4 HDR. 3 1/8x9 G.L.B. HDR. 6'-8" HDR. N/S2.5 5'-9 1/2" HDR. 4'-5" E/S2.6 E/S2.6 2'-3 1/2" HDR. 2 ELEVATION 1/2" = 1'-0" H 6'-8 1/2" 2- 2x12 2- 2x12 5'-0" MIN. H HDR. DROP H.S.S. 4x8x3/16 J CS16 STRAP 3 1/8x9 G.L.B. J CS16 STRAP CS16 STRAP I 2W6 H/S2.6 WATERPROOF MEMBRANE PER ARCH. B/S2.6 B/S1.3E G LEGEND: H.S.S. WHERE OCCURS STRUCTURAL WALL 3/4" STRUC-I PLYWOOD ON JOISTS RIPPED TO DRAIN PER ARCH. MIN 8 REMAIN. STRUCTURAL WALL BELOW 8'-0" 3/4" = 1'-0" I HDR. J/S2.6 D/S2.6 W10x12 DROP H.S.S. 4x8x3/16 FLAT OUTRIGGERS BRACE ELEVATION THIS SHEET HDR. 4'-5" 6'-8 1/2" I C:\Users\BHARATP\appdata\local\temp\AcPublish_9396\Terri Bella - East Unit - 48.dwg, 03-10-15, 7:13am, BHARATP, 48 B F SECTION 13'-8 1/2" 8'-3 1/2" Wx ROOF FRAMING PLAN -EAST- 5'-9 1/2" D/S2.6 OPP. 2'-3 1/2" H H.S.S. PER PLAN E F G PLATE 1/4"x6" w/ B/S2.4 332 4TH AVE KIRKLAND, WA 98033 4'-1 1/2" 4'-1 1/2" 3" XX C BE OL S P LO UM IPE W N D TERRI BELLA RESIDENCES -EAST UNIT- H.S.S. PER PLAN 3 1/8x9 G.L.B. D 45'-4 1/2" K/S2.6 3/16 1 E 3/4" = 1'-0" E/S2.5 HDR. 6'-8" W6 SECTION C E/S2.5 K/S2.6 W4 2x6 OUTRIGGERS @ 24"oc SLOPE PER ARCH. HDR. 9'-2 1/2" C W4 A 9'-2 1/2" 2x6 OUTRIGGERS @ 24"oc D/S2.6 OPP. 18530 Meridian AVE North Shoreline, WA 98133 206-779-6850 B 45'-4 1/2" B PLYWOOD SHEAR WALL PER 30'-0" PER SPAN DIRECTION OF JOISTS REVISIONS: 1 2 4 5 6 WOOD BEAM PER PLAN HDR 1 ROOF FRAMING PLAN 1/4" = 1'-0" NOTES: 1.) TYPICAL ROOF FRAMING CONSISTS OF 5/8" PLYWOOD ON 2x WOOD RAFTERS NAIL ALL SUPPORTED PANEL EDGES WITH 10d NAILS @ 6"oc & ALL INTERMEDIATE SUPPORTS WITH 10d NAILS @ 12"oc. 2.) TYPICAL ROOF RAFTERS SHALL BE SPACED @ 24"oc UNLESS OTHERWISE NOTED. 3.) BEAMS AT THIS LEVEL SHALL BE GL 3 1/8 x 9 OTHERWISE NOTED. 4.) TYPICAL EXTERIOR WALL SHALL BE FRAMED WITH 2x6 DF STUDS @ 16"oc, UNLESS OTHERWISE NOTED. TYPICAL INTERIOR WALLS SHALL BE FRAMED WITH 2x4 DF STUDS @ 16"oc UNLESS OTHERWISE NOTED. REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION PERTAINING TO WALL THICKNESSSES. 5.) TYPICAL EXTERIOR WALL HEADERS SHALL BE FRAMED WITH (3) PLIES OF 2x10 DF #2, UNLESS OTHERWISE NOTED 6.) TYPICAL EXTERIOR WALL W6, U.N.O. PER SHEAR WALL SCHEDULE ON S2.3. HD J H.S.S. 4x8x3x3/16 BEAM PEEN THREADS @ ROD 1 FLUSH OR DROP HEADER PER PLAN NOTE 5. 03-10-15 H/S2.6 SIMPSON HOLD DOWN ANCHOR CADD FILE: 8'-0" WOOD POST 15012 STEEL POST 1 2 DATE: 01-25-15 DRAWN: B. PATEL CHECKED: C. BURT 3 3RD FLOOR DECK FRAMING PLAN 1/2" = 1'-0" S1.3E JB212 HANGERS 2x6 @ 16"oc 2x6 @ 16"oc SHEATHING NAIL PER NOTES 2x BLKG. 4'-0"oc 4- 8d EACH BLK'G. SHEAR WALL PER PLAN SILL PLATE AND A.B. PER S.W. SCHEDULE JB212 HANGERS EDGE NAIL PER S.W. SCHEDULE 2- #5 CONT. SHEATHING PER PLAN JB212 HANGERS EDGE NAIL PER S.W. SCHEDULE STEM WALL PER C/S2.1 2- #5 CONT. EQ. EQ. PER PLAN EQ. B REINF. PER C/S2.1 STEM WALL PER C/S2.1 EQ. PER PLAN 3/4" = 1'-0" P.T. SILL PLATE AND ANCHOR BOLT PER S.W. SCHED. EQ. EQ. PER PLAN SECTION 3/4" = 1'-0" C EQ. PER PLAN SECTION 3/4" = 1'-0" D SECTION 3/4" = 1'-0" DOUBLE STUDS @ HOLD DOWN NOTE: SLAB NOT SHOWN BLOCK @ BEAM LINE SILL PLATE & ANCHOR BOLT PER S.W. SCHEDULE SHEARWALL PER PLAN ANCHOR PER SCHEDULE SIMPSON ACE GRADE VARIES NOTE: BALANCE OF INFO. PER C/S2.1 POST PER PLAN BEAM PER PLAN P.T. POST PER PLAN w/ BC4/PB44 P.T. PLATE NOTE: BALANCE OF INFO. PER C/S2.1 #4 @ 12"oc TRANSVERSE EQ. EQ. EQ. PER PLAN EQ. PER PLAN SECTION 3/4" = 1'-0" F PER PLAN SECTION 3/4" = 1'-0" G PER PLAN SECTION 3/4" = 1'-0" H SECTION 3/4" = 1'-0" NOTE: FLOOR ABOVE NOT SHOWN 1/4 2" MIN. W16 TO PLATE PLATE TO WALL C:\Users\BHARATP\appdata\local\temp\AcPublish_9396\Terri Bella - East Unit - 48.dwg, 03-10-15, 7:13am, BHARATP, 48 COLUMN PER PLAN 2'-0" LINE OF CONCRETE WALL BEYOND NEW 4" SLAB w/ 6x6 W1.4xW1.4 W.W.F. @ CENTERLINE #4 PLATE 1/2"4"x0'-10" w/ EMBED 8" @ 16"oc 3- #4 ASPHALT/CONCRETE DRIVEWAY PER PLAN @ TOP 8"oc SLAB ON GRADE PER PLAN W16 PER PLAN 18" NON-SHRINK GROUT CONCRETE STEM WALL 332 4TH AVE KIRKLAND, WA 98033 SIMPSON HOLDOWN SEE PLAN FOR TYPE AND LOCATION TERRI BELLA RESIDENCES BEAM PER PLAN 2- #4 PLATE 1/2"x8"x0'-4" 4" WELD #5 @ END TO 1/2" PLATE FOUNDATION SECTIONS SHEAR WALL PER PLAN E City of Kirkland Reviewed by R Braun 03/11/2015 2- #5 CONT. EQ. SECTION JOIST PER PLAN 8" C.I.P. WALL w/ #5 VERT. @ 16"oc @ CENTERLINE #4 HORIZ. @ 12"oc STEM WALL PER C/S2.1 2- #5 CONT. A GRADE VARIES P.T. SILL PLATE AND ANCHOR BOLT PER S.W. SCHED. GRADE VARIES 18530 Meridian AVE North Shoreline, WA 98133 206-779-6850 P.T. SILL PLATE AND ANCHOR BOLT PER S.W. SCHED. GRADE VARIES SLAB AND REINF. PER PLAN #5 @ 12"oc E.W. NOTE: BALANCE OF INFO. PER C/S2.1 REVISIONS: 1- #5 TOP & BOTTOM 1 03-10-15 CONTINUE BARS INTO FA 4" PERFORATED PVC DRAINPIPE w/ HOLES DOWNWARD SLOPE TO STORM DRAIN BACKFILL WITH FREE DRAINING MATERIAL 8" EQ. EQ. CADD FILE: 15012 PER PLAN 4'-0" DATE: 01-25-15 DRAWN: B. PATEL CHECKED: C. BURT J SECTION 3/4" = 1'-0" K SECTION 3/4" = 1'-0" L SECTION 3/4" = 1'-0" M SECTION 3/4" = 1'-0" S2.1 STUDS PER PLAN MULTIPLE JOISTS OR SOLID BLOCKING SAME THICKNESS AS POST ABOVE MAXIMUM SPACING & LOCATION PER FOUNDATION PLAN 2- 2x STUDS @ END OF EACH SHEAR WALL PER SHEAR WALL SCHEDULE 1/8" SAWN JOINT C.I.P. CONC. WALL SLAB PER PLAN CONT. FTG. HOLDOWN PER PLAN @ CENTERLINE OF STUD w/ ALL-THREAD EMBEDDED PER PLAN TOP OF CONCRETE REINFORCING PER PLAN @ CENTERLINE SLAB 2x PRESSURE-TREATED SILL PLATE City of Kirkland Reviewed by R Braun 03/11/2015 2 1 1'-6" 4- #5 18530 Meridian AVE North Shoreline, WA 98133 206-779-6850 SHEATHING & NAILING PER SHEAR WALL SCHEDULE 1'-6" TYPICAL HOLDDOWN DETAIL @ FOUNDATION AND FRAMED FLOOR 1.5 H A SECTION B 3/4" = 1'-0" SECTION C 3/4" = 1'-0" SECTION 3/4" = 1'-0" CENTERLINE PLINTH & FOOTING ANCHOR BOLT (WITHIN 12" OF END OF PLATE) PER SCHEDULE PLYWOOD SHEATHING 2x STUD HOLDOWN PER PLAN REINF. PER SCHED. EDGE NAILING ALTERNATE CORNER BARS TYPICAL HOLD DOWN @ CORNERS MIN. 2- END STUDS, FACE NAIL w/ 1/2 OF S.W. EDGE NAILING, STAGGERED 12"x12" C.I.P. PLINTH w/ 4- #6 VERT. & 3- #3 TIES @ 1 1/2"oc TOP & REMAINDER @ 4"oc ADDITIONAL STUD FOR SHEAR WALL EDGE NAILING. FACE NAIL SAME AS EDGE NAILING. [PER PLAN] CORNER BARS TO MATCH HORIZ. REINF. C.I.P. WALL PER PLAN SIMPSON STRAP PER PLAN USE ALL SPECIFIED FASTENERS PER SIMPSON 2- #5 @ CENTERLINE OF PIER (OMIT AT PIERS 12" WIDE OR LESS) CROSS WALL PER PLAN 2- #5 TYP. @ OPENINGS EXTEND BARS 2'-0" MIN. BEYOND OPENING, HOOK AS NECESSARY CONCRETE WALL WRAP AROUND #4 BAR MIN. @ CORNER PER WIDTH 332 4TH AVE KIRKLAND, WA 98033 SIMPSON CBSQ POST BASE #3 TIES @ 10"oc (WHEN PIER WIDTH EXCEEDS 24" USE TYP. HORIZ. REINF.) TERRI BELLA RESIDENCES DOUBLE 2x OR 4x 1 1/2" MIN. CORNER CONDITION @ C.I.P. WALL F3.0 - 3'-0"x3'-0"x0'-11" TYPICAL OPENING REINF. @ CONCRETE WALLS C:\Users\BHARATP\appdata\local\temp\AcPublish_9396\Terri Bella - East Unit - 48.dwg, 03-10-15, 7:13am, BHARATP, 48 D SECTION 3/4" = 1'-0" E SECTION 3/4" = 1'-0" F SECTION 3/4" = 1'-0" G SECTION 3/4" = 1'-0" NOTES: 1.) REINFORCING SHOWN IS MINIMUM. SEE PLANS, WALL ELEVATION FOR ANY ADDITIONAL REQ'D. REINF. 2.) THIS DETAIL APPLES TO ALL WALL OPENINGS, UNLESS NOTED OTHERWISE ON PLANS, ELEVATONS, OR DETAILS. FOUNDATION SECTIONS w/ 3- #5 E.W. BOT. REVISIONS: 1 03-10-15 CADD FILE: 15012 DATE: 01-25-15 DRAWN: B. PATEL CHECKED: C. BURT S2.2 16d @ 6"oc SHEAR WALL SCHED. (DOUG FIR OR HEM-FIR LUMBER PER GEN. NOTES) 16d @ 6"oc A35 @ 2'-0"oc APA RATED SHEATHING (NOTES 1,2,4,12,13) JOIST PER PLAN EDGE NAILING PER SHEAR WALL SCHEDULE 2X WALL PLATE TO BLOCKING / RIM (NOTE 9) SILL PLATE ATTACHMENT FOUNDATION 5/8" DIA ANCHOR SILL PLATE BOLT SPACING (NOTE 11) (NOTES 10,15) DOUG-FIR SHEAR CAPACITY (PLF) HEM-FIR SHEAR CAPACITY (PLF) APPLICATION PANEL EDGE NAIL SPACING (NOTES 4,5) W6 ONE SIDE 0.131 X 2-1/2 @ 6" OC 2x CLIP @ 20"oc 0.148 X 3-1/4 @ 6" oc 40"oc 2x 260 242 W4 ONE SIDE 0.131 X 2-1/2 @ 4" OC 2x CLIP @ 14"oc 0.148 X 3-1/4 @ 4" oc 28"oc 2x 380 353 W3 ONE SIDE 0.131 X 2-1/2 @ 3" OC 2x CLIP @ 11"oc 0.148 X 3-1/4 @ 3" oc 21"oc 2x 490 455 2W6 BOTH SIDES 0.131 X 2-1/2 @ 6" OC 3x (2) CLIPS @ 20" oc (2) CLIPS @ 20" oc 26"oc 3x 520 484 2W4 BOTH SIDES 0.131 X 2-1/2 @ 4" OC 3x (2) CLIPS @ 14" oc (2) CLIPS @ 14" oc 18"oc 3x 760 2W3 BOTH SIDES 0.131 X 2-1/2 @ 3" OC STAGGERED 3x (2) CLIPS @ 11" oc (2) CLIPS @ 11" oc 12"oc 2x 980 2W2 BOTH SIDES 0.131 X 2-1/2 @ 2" STAGGERED 3x (3) CLIPS @ 12" oc (3) CLIPS @ 12" oc 10"oc 3x 1280 JOIST PER PLAN EDGE NAILING PER SHEAR WALL SCHEDULE RIM JOIST/BLOCK TO TOP PLATE (NOTES 7,8) STUD & EDGE BLK'G (NOTES 3,6,14) MARK City of Kirkland 706 Reviewed by R Braun 912 03/11/2015 JOIST BLOCKING @ 48"oc 1190 SHEARWALL SCHEDULE NOTES: 2. WHERE SHEATHING IS APPLIED ON BOTH SIDES OF WALL, PANEL EDGE JOINTS ON 2X FRAMING SHALL BE STAGGERED SO THAT JOINTS ON OPPOSITE SIDES ARE NOT LOCATED ON THE SAME STUDS 10. WHERE PLATE ATTACHMENT SPECIFIES (2) ROWS OF NAILS, PROVIDE DOUBLE JOIST, RIM, OR EQUAL. ATTACH PER DETAILS 18530 Meridian AVE North Shoreline, WA 98133 206-779-6850 1. INSTALL PANELS EITHER HORIZONTALLY OR VERTICALLY FOR ENTIRE LENGTH SHOWN ON PLANS 11. IN SEISMIC DESIGN CATEGORY D, E, AND F, ANCHOR BOLTS SHALL BE PROVIDED WITH 3x3x1/4" PLATE WASHERS. EMBED ANCHOR BOLTS 7" INTO CONCRETE. 1 3. BLOCKING IS REQUIRED AT ALL PANEL EDGES. 5. SHEATHING EDGE NAILING IS REQUIRED AT ALL HOLDDOWN POSTS. EDGE NAILING MAY ALSO BE REQUIRED TO EACH STUD USED IN BUILT-UP HOLDDOWN POSTS. REFER TO THE HOLDDOWN DETAILS FOR ADDITIONAL INFORMATION. 3/4" = 1'-0" 6. INTERMEDIATE FRAMING TO BE WITH 2X MINIMUM MEMBERS. FIELD NAILING SHALL BE AT 12"oc MAX. 7. USE 0.131 X 1 1/2" LONG NAILS TO ATTACH FRAMING CLIPS DIRECTLY TO FRAMING. USE 0.131x2 1/2" NAILS WHEN CLIPS ARE INSTALLED OVER SHEATHING. 8. FRAMING CLIPS ARE EITHER A35 OR LTP5, OR APPROVED EQUIVALENT 9. FOR ALL SLOTTED PLATE WASHERS ARE ACCEPTABLE SHEAR WALLS, LOCATE THE PLATE WASHERS WITHIN 1/2" OF SHEAR PANEL SHEATHING. 1 2- TOP PLATE U.N.O. TYPICAL EDGE NAILING, SEE NOTES 3/8" MIN. TO EDGE OF PLYWOOD SHEET & SUPPORT 13. EDGE NAILS SHALL BE LOCATED 3/8" FROM PANEL EDGES. 1 14. 7/16" APA RATED SHEATHING (OSB) MAY BE USED IN LIEU OF 15/32" SHEATHING PROVIDED THAT ALL STUDS ARE SPACED 16" OC AND ENGINEER OF RECORD HAS BEEN NOTIFIED IN WRITING AND APPROVES. 15. WHERE WOOD SHEATHING IS APPLIED OVER GYPSUM WALL BOARD SHEATHING (GWB), CONTACT ENGINEER OF RECORD FOR APPROVAL AND ALTERNATE FASTENING REQUIREMENTS. 16. AT ADJOINING PANEL EDGES, (2) 2X STUDS NAILED TOGETHER MAY BE USED IN LIEU OF A SINGLE 3X STUD. DOUBLE 2X STUDS MAY BE CONNECTED TOGETHER WITH 3" NAILS OF THE SAME SPACING AND DIAMETER AS THE PLATE NAILING. 17. CONTACT ENGINEER OF RECORD FOR ADHESIVE OR EXPANSION BOLT ALTERNATIVES TO CAST-IN-PLACE ANCHOR BOLTS. TYPICALLY SET-XP ADHESIVE WILL BE ALLOWED AS AN ALTERNATE. 1 EDGE NAIL TO TOP PLATE FLOOR/ROOF JOIST PER PLAN 2x4 FLAT BLOCKING @ PLYWOOD EDGES, PERPENDICULAR TO FLOOR/ROOF JOIST WHERE NOTED ON PLANS OR NOTES FIELD NAIL 2x BLOCKING, EDGE NAIL 3x WHEN NOTED ON SCHEDULE. SHEATHING PER SCHEDULE 332 4TH AVE KIRKLAND, WA 98033 3/4" = 1'-0" B SECTION 12. PRESSURE PRESERVATIVE TREATED STAINLESS OR MATERIAL CAN CAUSE EXCESSIVE CORROSION AND DEGRADATION OF FASTENERS. PROVIDE HOT DIPPED GALVANIZED NAILS AND CONNECTOR PLATES FOR ALL CONNECTORS IN CONTACT WITH PRESERVATIVE TREATED FRAMING MEMBERS. TERRI BELLA RESIDENCES A SECTION 4. PROVIDE SHEAR WALL SHEATHING AND NAILING FOR THE ENTIRE LENGTH OF THE WALLS INDICATED ON THE PLANS. ENDS OF FULL HEIGHT WALLS ARE DESIGNATED BY EXTERIOR OF THE BUILDING, CORRIDORS, WINDOWS, OR DOORWAYS OR AS DESIGNATED ON THE PLANS. SEE PLANS FOR HOLDDOWN REQUIREMENTS. ALTERNATE WALLS DESIGNATED AS PERFORATED SHEARWALLS REQUIRE SHEATHING ABOVE AND BELOW ALL OPENINGS. NOTE: NAILING TO BE 3/8" MIN. TO EDGE OF SUPPORTS & SHEETS TYPICAL INTERMEDIATE NAILING PER NOTES SCHEDULES C:\Users\BHARATP\appdata\local\temp\AcPublish_9396\Terri Bella - East Unit - 48.dwg, 03-10-15, 7:13am, BHARATP, 48 NOTE: ALL ENDS OF PLYWOOD SHEETS TO SPLICE OVER CENTERLINE JOISTS OR SUPPORTING MEMBERS. BLOCK ALL PANELS LESS THAN 12" IN WIDTH STAGGER PLYWOOD JOINTS, SEE PLANS 2x SILL PLATE HOLDDOWNS PER PLAN FINISH FLOOR LINE ANCHOR BOLTS SEE SCHEDULE TYPICAL FLOOR/ROOF SHEATHING C PLAN VIEW 1/2" = 1'-0" NOTES: 1.) ANCHOR SHALL BE ASTM A307 HEADED ANCHOR BOLT, UNLESS NOTED OTHERWISE. CONNECT TO FOOTING PER XX / THIS SHEET 2.) WOOD MEMBERS (MIN) ABOVE AND BELOW WHERE OCCURS AT FLOOR LEVEL. DO NOT USE LAG BOLTS TO FASTEN HOLDOWNS TO WOOD MEMBERS. 3.) HOLDOWN SCHEDULE IS PROVIDED FOR GENERAL INSTALLATION INFORMATION. NOT ALL OF HARDWARE SCHEDULED IS REQUIRED SEE PLANS FOR HOLDOWN CALL-OUTS AND LOCATIONS. CONSULT MANUFACTURER FOR ADDITIONAL INFORMATION. 4.) QUANTITY OF NAILS FOR STRAPS ARE EVENLY DIVIDED BETWEEN ENDS OF STRAPS ABOVE AND BELOW THE DEPTH OF THE FLOOR SYSTEM, SEE M/S2.4. USE 16d COMMON NAILS, U.N.O. 5.) IF SHEAR WALL REQUIRES 3x STUDS, USE 3x INSTEAD OF 2x. 6.) PHDX ANCHORS REQUIRE SIMPSON SDS 1/4x3 WOOD SCREWS. 7.) SEE DETAILS F/S2.2 AND J/S2.2 FOR INSTALLATION. REVISIONS: 1 03-10-15 TYPICAL WALL FRAMING D CADD FILE: SECTION 15012 3/4" = 1'-0" DATE: 01-25-15 DRAWN: B. PATEL CHECKED: C. BURT S2.3 Special Inspection Required for welding 1 PER PLAN 4x BLOCKING FULL DEPTH w/ U410 HANGERS 2x PLATE PER ARCH. TRIPLE 2x BLOCKING OVER RIM OR BLOCKING NOTE: BEAMS CAN BE DROPPED OR FLUSH PER ARCH. THIS LOCATION COLUMN PER ARCH. A35 PLATE 3/16"x4" HD PER PLAN POST PER PLAN 2x NAILER 1 BEAM PER PLAN KERF FOR WT FIT PER ARCH. 1/4" STIFFENER PLATE 3/16 PLATE 3/8"x12"x6" w/ 3/16 ANCHOR TO BEAM POST PER PLAN AND SCHEDULE H.S.S. COLUMN PER PLAN City of Kirkland Reviewed by R Braun 03/11/2015 1 2x NAILER w/ NAILER 3/16 BASE PLATE 4"x0'-10" 3/16 1 2ND FLOOR 2- MST48 ACROSS RUN 1 WT6x8 x 0'-6" w/ 3/16 1 BEAM PER PLAN BLOCKING BEYOND A SECTION B 3/4" = 1'-0" 4x3 1/2x1/4x1'-0" L.L.V. w/ 3 SIMPSON 1/4"x3" SDS EACH SIDE OF BEAM SECTION C 3/4" = 1'-0" SECTION 3/4" = 1'-0" JOIST PER PLAN PLATE 1/2"x6"x0'-7" w/ BEAM PER PLAN 3/16 D E 3/4" = 1'-0" BEAM PER PLAN FILL WEB FULL WIDTH w/ SOLID BLOCKING THROUGH BOLT w/ 1 H.S.S. COLUMN PER PLAN SECTION 18530 Meridian AVE North Shoreline, WA 98133 206-779-6850 1/4" STIFF. PLATE SECTION 3/4" = 1'-0" BEAM PER PLAN. PERPENDICULAR NOT SHOWN FOR CLARITY FULL HEIGHT STUD, TYP. 2- 2x BEARING STUDS, TYP. U.N.O. SEE PLANS STUDS TO MATCH BEAM WIDTH NAIL STUD TOGETHER w/16d @ 12"oc TYP. 3- 16d THRU WALL KING STUD SIMPSON ACE POST CAP EA. SIDE POST PER PLAN KING STUD WHERE WALL IS PARALLEL TO BEAM 2- STUDS AT EACH HOLDDOWN MIN., SEE PLAN FOR FOR ADDITIONAL POSTS AND TYPICAL POSTS UNDER BEAM STUDS TO MATCH BM WIDTH (MIN. 2) U.N.O. ON PLANS 2x SILL PLATE SEE PLANS & SHEARWALL SCHEDULE WINDOW SILL CROSS WALL PLAN SIMPSON AC/ACE MIN. EACH SIDE PERPENDICULAR PARALLEL CORNER PLAN TYPICAL BEAM TO WALL TYPICAL WALL INTERSECTION F SECTION TYPICAL STUD FRAMING DETAIL @ OPENING G 3/4" = 1'-0" BEAM TO WOOD POST CONNECTION SECTION H 3/4" = 1'-0" J SECTION SECTION 3/4" = 1'-0" 3/4" = 1'-0" 8- 16d NAILS EA. SIDE OF SPLICE C:\Users\BHARATP\appdata\local\temp\AcPublish_9396\Terri Bella - East Unit - 48.dwg, 03-10-15, 7:13am, BHARATP, 48 (NO BOT. SPLICE IN THIS AREA) 16d @ 12"oc STAGGER TYP. 4'-0" 4'-0" MIN. MIN. NOTCH PLYWOOD AS REQ'D FOR STRAP STAGGER TOP PLATE 4'-0" MIN. TYPICAL NOTE: AT ALL EXTERIOR WALLS USE 20d FOR 3x PLATE TYPICAL STUDS PER PLAN/DETAIL HEADER PER PLAN 2x6 STUDS @ 16"oc ABOVE AND BELOW SEE PLAN 16d @ 12"oc STAGGER TYP. PLAN 16d NAILS SEE SHEAR WALL SCHED. FOR SPACING TYPICAL SINGLE TRIMMER STUD. MULTIPLE TRIMMER STUDS WHERE REQUIRED PER PLAN OR PER NOTES/SPECIFIC DETAIL TOP PLATE SPLICE AT STUD CENTERLINE, TYP. BOTTOM PLATE SPLICE AT STUD CENTERLINE, TYP. STRAP & NAILING PER PLANS & HOLDDOWN SCHED. MULTIPLE JOISTS OR SOLID BLOCKING SAME THICKNESS AS STUD OR POST 2- 2x TOP PLATES 2x6 STUDS 2x4 PLATE 2x6 PLATE 2- 2x HEADER HEADER PER PLAN, U.N.O. REVISIONS: 1/2" PLYWOOD FILLER PROVIDE DOUBLE STUDS OR POST AT STRAP LOCATIONS, SEE SCHED. SINGLE FULL HEIGHT KING STUD. MULTIPLE KING STUDS WHERE REQ'D. PER PLAN 2x4 STUDS 2x PLATE 2- 16d EA SIDE OF BOTTOM PLATE SPLICE 3- 16d 332 4TH AVE KIRKLAND, WA 98033 CROSS WALL BEAM PER PLAN EDGE NAILING PER SHEARWALL SCHEDULE, TYP. FLOOR FRAMING SECTIONS EXTRA STUDS AS SHOWN, SEE PLAN FOR ADDITIONAL POSTS AND TYPICAL POSTS UNDER BM. TERRI BELLA RESIDENCES BEAM PER PLAN 3 1/2" 1/2" PLYWOOD FILLER, TYP. 5 1 03-10-15 CADD FILE: 15012 TYPICAL HEADER SUPPORT DETAIL ELEVATION STUD WALL TOP PLATE SPLICE K SECTION 3/4" = 1'-0" L SECTION 3/4" = 1'-0" TYPICAL FLOOR TO FLOOR HOLD DOWN STRAP M SECTION 3/4" = 1'-0" TYPICAL HEADER SECTIONS N DATE: 01-25-15 DRAWN: B. PATEL CHECKED: C. BURT SECTION 3/4" = 1'-0" S2.4 4x POST @ 8'-0"oc MAX. RAILING BY OTHERS 8d @ 6"oc 2x BLKG. CONT. DECKING PER PLAN SIMPSON DTT2Z SIMPSON A35 JOIST PER PLAN POST PER PLAN 2x6 FLAT RAILING, TYP. SIMPSON A35 H2A EA. SIDE TYP. CANTILEVER WALL CONNECTION SECTION B 3/4" = 1'-0" RAILING ANCHORAGE SECTION C 3/4" = 1'-0" SECTION D 3/4" = 1'-0" 2x6 STUDS @ 16"oc 2x12 RIM JOIST w/ FULL DEPTH BLOCKING AT INSIDE NOTCH PLYWOOD AS REQ'D. FOR STRAP SIMPSON STRAP PER PLAN CENTER AT END OF BEAM BEAM TO JOIST CONNECTION SECTION E 3/4" = 1'-0" 2x6 STUDS @ 16"oc 16d NAILS SEE SHEAR WALL SCHED. FOR SPACING NOTCH PLYWOOD AS REQ'D. FOR STRAP 2x PLATE 16d NAILS SEE SHEAR WALL SCHED FOR SPACING SECTION 3/4" = 1'-0" SHEARWALL PER PLAN PLYWOOD SHEATHING ANCHOR BOLT (WITHIN 12" OF END OF PLATE) PER SCHEDULE HOLD DOWN PER PLAN 2x STUD DOUBLE 2x OR 4x . STRAP & NAILING PER PLANS & HOLDOWN SCHED. SOLID BLOCKING SAME THICKNESS AS STUD OR POST STRAP & NAILING PER PLANS & HOLDOWN SCHED. DRAG STRAP DETAIL F TYPICAL FLOOR FLUSH BEAM HOLD DOWN STRAP SECTION 3/4" = 1'-0" G BEAM PER PLAN COUNTERSINK BOLT/WASHER EDGE NAILING HOLDOWN PER PLAN BEAM PER PLAN WRAP STRAP UNDER BEAM NECESSARY CENTERLINE BOLT BEAM TYPICAL FLOOR FLUSH BEAM HOLD DOWN STRAP SECTION H 3/4" = 1'-0" SECTION TYPICAL HOLDOWN @ CORNERS (PLAN) J 3/4" = 1'-0" FLOOR FRAMING SECTIONS BEAM PER PLAN SECTION 3/4" = 1'-0" 1 1/2" 2- ROWS OF 10d @ 6"oc, DRIVE ADJACENT NAILS FROM OPP. SIDE C:\Users\BHARATP\appdata\local\temp\AcPublish_9396\Terri Bella - East Unit - 48.dwg, 03-10-15, 7:13am, BHARATP, 48 CENTERLINE OF NAILS SIMP. U212 HANGER, U212-2 AT DBL. HDR. LANDING JOIST OR FLOOR JOIST 2- 2x6 BUILT-UP POST PIPE COLUMN PLAN 11/2" LSL STRINGER 1 1/2" PLATE 1/4"x6"x6" EACH SIDE 3/16 2 1/2" 2- 2x8 HEADER BEAM PER PLAN 1 EACH PLATE SIMP. 'U' HANGER 3/16 NOTE: USE IN LIEU OF SINGLE 3x AT PANEL EDGES, TYPICAL LANDING JOIST OR FLOOR JOIST REVISIONS: CAP PLATE 1/4"x4"x4" BEAM PER PLAN 3/16 BUILD-UP STUD AT SHEAR WALL STRINGER 2- 2x8 18530 Meridian AVE North Shoreline, WA 98133 206-779-6850 STUD WALL SEE PLAN AND SHEARWALL SCHEDULE HEADER PER PLAN POST PER PLAN A JOIST PER PLAN w/ SIMPSON 'U' FACE HANGER OR SIMPSON 'JB' OR FLANGE HANGER BEAM PER PLAN 332 4TH AVE KIRKLAND, WA 98033 2x6 CEDAR NAILER w/ 16d @ 6"oc TYP. @ DECKING BLOCKING @ 24"oc w/ LU HANGERS JOIST PER PLAN TERRI BELLA RESIDENCES CANTILEVERED BEAM PER PLAN City of Kirkland Reviewed by R Braun 03/11/2015 COLUMN PER PLAN 1 03-10-15 NOTE: RAFTERS NOT SHOWN SIMP. U212 HANGER, U212-2 AT DBL. CADD FILE: 15012 K SECTION 3/4" = 1'-0" L SECTION 3/4" = 1'-0" M SECTION 3/4" = 1'-0" N SECTION 1 DATE: 01-25-15 DRAWN: B. PATEL CHECKED: C. BURT 3/4" = 1'-0" S2.5 1 2x FULL DEPTH BLOCKING 2x NAILER x FULL WIDTH OF BEAM w/ DOUBLE 2x6 TOP PLATE. STAGGER SPLICES 4'-0" TYPICAL 4" LAP NAIL 3- 10d TYP. PLYWOOD PER PLAN COUNTER SINK 2x6 (MIN) OUTRIGGERS @ 24"oc BLOCKING NOTCH FOR FULL BEARING BLOCKING FULL WIDTH OF WEB @ W16 SHEATHING PER PLAN SPLICE RAFTERS FASCIA & SOFFIT DETAIL PER ARCH. SIMPSON H2.5, TYP. 2x VENTED BLK'G. * BUILT-UP HEADER. LOCATE/ELEVATE AS REQ'D. * JOISTS PER PLAN SIMP. LTP4 SPACING PER WALL SCHEDULE SIMPSON U HANGER BEAM PER PLAN NOTE: BALANCE PER A/S2.6 RAFTER PER PLAN H2.5 TYP. * = 10d @ 6"oc City of Kirkland Reviewed by R Braun JOIST PER PLAN JB212 TOP FLANGE 03/11/2015 HANGER, TYPICAL USE ALL NAILS TO ROOF NAILER 18530 Meridian AVE North Shoreline, WA 98133 206-779-6850 PLYWOOD PER SHEAR WALL SCHED. CONT. UP TO BOT. OF OUTRIGGERS * = 10d @ 6"oc B 3/4" = 1'-0" C SECTION 3/4" = 1'-0" D SECTION 3/4" = 1'-0" E SECTION 3/4" = 1'-0" 1 PLATE 1/4"x4"x8" w/ INTO CORNER POST 3/16 2x NAILER BLOCKING @ BEARING LET IN FLAT 2x OUTLOOKER PLATE 3/16"x4"x12" w/ 8- SDS 1/4"x4" SCREWS TO STUD H.S.S. PER PLAN BLOCKING NAILER JOIST PER PLAN BEAM PER PLAN ROD w/ CLEVIS H.S.S. PER PLAN H.S.S. PER PLAN SHEARWALL PER PLAN H.S.S. TO H.S.S. 3/16 PLATE 3/16x3"x4" w/ 1 H.S.S. BEYOND PSL POST PER PLAN 332 4TH AVE KIRKLAND, WA 98033 3/4" = 1'-0" SECTION TERRI BELLA RESIDENCES A SECTION BEAM PER PLAN C:\Users\BHARATP\appdata\local\temp\AcPublish_9396\Terri Bella - East Unit - 48.dwg, 03-10-15, 7:13am, BHARATP, 48 F PLATE 1/4"x8" w/ 4- SDS 1/4"x3" SCREWS TO 4x BEAM SECTION 3/4" = 1'-0" G SECTION 3/4" = 1'-0" H SECTION 3/4" = 1'-0" J SECTION 3/4" = 1'-0" K SECTION 3/4" = 1'-0" ROOF FRAMING SECTIONS SIDE OF FRONT REVISIONS: 1 03-10-15 CADD FILE: 15012 DATE: 01-25-15 DRAWN: B. PATEL CHECKED: C. BURT S2.6 JGM LEGEND TREE #204 REAR SETBACK 5' - 0" 30' - 0" 5' - 0" TREE # 2 TREE # 3 REAR PATIO 63 SF LANDSCAPE ARCHITECTURE URBAN DESIGN SITE PLANNING PARKS AND RECREATION PLANNING 12610 NE 104TH ST. KIRKLAND WA 98033 PH: 425.454.5723 FX: 425.822.3525 E-: jgm@jgm-inc.com City of Kirkland Reviewed by R Braun 03/11/2015 120.00' 10' - 0" REAR PATIO 63 SF 112' - 0" TREE # 1 111' - 0" N 89'47'36"E " PROPERTY LOT LINE 110' - 0 " TREE #205 109' - 0" 108' - 0" 0 107' - 0" 106' - 105' - 0" 104' - 0" -0 " 0" " " 103' - 0" 10 2' -0 '0 101 ' - 10 0 99 ' 98' - 0" 97' - 0" LOCALIZED FILL MAY BE REQ'D AS PART OF THE INFILTRATION TRENCH INSTALLATION IN ORDER TO MAINTAIN MIN. COVER OVER THE 6" DIAMTER TRENCH OVERFLOW PIPE. PER CIVIL DRAWINGS INCORPORATED P.S. REAR PATIO 63 SF TREE #106 LOT 9 F.F.E. 100.12' F.F.E. 104.29' F.F.E. 107.27 CONCRETE WALKWAY 82 SF TREE # 4 N00'36'24"W TREE #202 COVERED FRONT ENTRY 87 SF 107.15 CONCRETE WALKWAY 82 SF TREE #201 TREE #104 2.0 % 2.0 % BOTTOM EL=93.0 5' - 0" 106.68 TREE # 7 110.38 WATER METER TYP. PER CIVIL DRAWINGS PROPERTY LOT LINE BOTTOM EL=96.0 110.27 110.40 111' - 0" 0" 112' - 0" 110' - " 0" '-0 109 DRY WELL OVERFLOW CATCH BASIN 6" SD IE=101.0 PER CIVIL DRAWINGS 108' - " '-0 107 - 0" 106' 0" 105' " 0" '-0 104 103' - " 102' - 0 101' - 0" DRY WELL DRY WELL OVERFLOW CATCH BASIN 6" SD IE=98.0 PER CIVIL DRAWINGS 2.0 % 102.98 120.00' 106.56 2.0 % 2.0 % BOTTOM EL=91.7 3 SISTERS LLC TREE # 6 106.66 102.85 TREE #105 DRIVEWAY 394 SF TREE # 5 2.0 % 5' - 0" CONCRETE WALKWAY 82 SF DRIVEWAY 394 SF 102.96 STUB TO ROOF, DRIVEWAY AND FOOTING DRAINAGE (TYP) PER CIVIL DRAWINGS 104.16 107.18 5' - 0" 14.9 % DRIVEWAY 394 SF 5' - 0" 11.5 % 21' - 8 3/4" 13.5 % 5' - 0" 2.0 5' - 0" 4" SD IE=97.0 PER CIVIL 5' - 0" DRAWINGS COVERED FRONT ENTRY 87 SF TREE #102 104.19 4" SD IE=100.0 PER CIVIL DRAWINGS 2.0 PROPERTY LOT LINE PROPERTY LOT LINE 4" SD COVERED IE=95.7 PER CIVIL FRONT ENTRY DRAWINGS 87 SF FRONT SETBACK 20' - 0" TREE #103 LINE OF GARAGE 112' - 0" LINE OF GARAGE 111' - 0" 5' - 0" 110' - 0" LINE OF FRONT SETBACK FROM PROPERTY LINE LINE OF GARAGE HOUSE FOOTPRINT 1244 SF 109' - 0" TREE #101 80.00' LOT 8 PROPERTY LOT LINE LOT 7 PROPERTY LOT LINE 80.00' TREE #203 RELOCATE EX. WATER METER AS REQUIRED PER CIVIL NOTES L1.0 City of Kirkland Reviewed by R Braun 03/11/2015 City of Kirkland Reviewed by R Braun 03/11/2015 City of Kirkland Reviewed by R Braun 03/11/2015 City of Kirkland Reviewed by R Braun 03/11/2015 City of Kirkland Reviewed by R Braun 03/11/2015 City of Kirkland Reviewed by R Braun 03/11/2015 City of Kirkland Reviewed by R Braun 03/11/2015 City of Kirkland Reviewed by R Braun 03/11/2015