Cable Management System
Transcription
Cable Management System
Catalogue Nº 219 SUBSIDIARIES: PEMSA UK: Unit 2. Hunslet Trading Estate Severn Road, LEEDS LS10 1BL Tel.: 0113 277 9090 Fax.: 0113 277 5939 sales@pemsa.co.uk Metal tray and channel system for cable support and management PEMSA PORTUGAL: Estrada de Polima. Centro Industrial de Abóboda Edificio Fase 2. 2ºK 2785-543 São Domingos de Rana Tel: +351 21 444 5725 Fax: +351 21 444 5727 pemsa.portugal@pemsa-rejiband.com PEMSA FRANCE: ZI Le clos aux pois. 12 Rue de la Closerie, 91090 LISSES Tél.: 01 60 86 75 65 Telécopie: 01 60 87 11 83 service-client@pemsa.fr www.pemsa.fr HEADQUARTERS: PEMSA SPAIN: Galileo Galilei, 22-24. P.E. La Garena 28806 Alcalá de Henares. Madrid Tel: +34 91 802 34 88 Fax: +34 91 802 33 81 info@pemsa-rejiband.com Cable Management System Metal tray and channel system for cable support and management www.pemsa-rejiband.com cod. CYNW. E305934 F o r f u r t h e r i n f o r m a t i o n re g a rd i n g t h e s e c e r t i f i c a t e s p l e a s e c h e c k w i t h i n t h e d o c u m e n t . Depósito Legal: M-12392-2008 Catalogue Nº 219 E-mail: info@pemsa-rejiband.com General Catalogue General Catalogue Origin, development and current position Pemsa was founded in Madrid in 1969, and today it is a company engaged in the manufacture of metal tray and channel systems for the support and management of medium and low voltage electric cables, as well as the manufacture of flexible tubing, connectors, compression glands and accessories. Pemsa heads the ranking of Spanish manufacturers of metal cable trays and is second at the European level as manufacturer of wire mesh cable trays of electrically welded steel. Moreover, Pemsa is one of the top 10 leading European manufacturers. New facilities At the end of 2002, the company inaugurated its new facilities at Alcalá de Henares, (Madrid). The current surface area exceeds 45,000 m2, of which 10,500 m2 consists of building space, including 1500 m2 assigned to offices and administrative departments.The new factory is equipped with the most modern technology available in the world today. This technology also extends to the warehouse and central offices, which include the various commercial and marketing departments, the Technical Office, Production, Quality, Exports, Logistics and Customer Service. The capacity of these new facilities may be doubled in the future. Metal tray and channel system for cod. CYNW. E305934 F o r f u r t h e r i n f o r m a t i o n re g a rd i n g t h e s e c e r t i f i c a t e s p l e a s e c h e c k w i t h i n t h e d o c u m e n t . Innovation and quality Since the beginning, Pemsa has been distinguished by the design and manufacture of innovative products that facilitate assembly and installation. Thus, Pemsa was the first Spanish manufacturer to introduce the "Rejiband" wire mesh cable tray into the market, its star product leading the market and the commercial brand that has become a generic name. New products were subsequently introduced in the sector, such as the Rejitech system, specifically designed for ceilings and false ceilings; or Inducanal, a special metal channel with reduced dimensions for installations over large surface areas. Currently, the company has one of the most complete product catalogues on the market, with the greatest number of solutions for metal trays, supports and structures. Moreover, Pemsa has enjoyed ISO 9001 certification since 1997, one of the first European manufacturers to obtain it. cable support and management. PEMSA-CAT 219-2-12-REV 27/11/09 11:30 Página 1 Commercial network Pemsa currently has five commercial offices, located in Madrid, Catalunya, the Basque Country, Levante and Andalusia, as well as commercial representatives distributed throughout Spanish territory. The export office is located at our central offices in Alcalá de Henares, (Madrid). Chronological milestones 1969: First facility on Calle Nicaragua in Madrid, with 80 square metres. 1974: Transfer to facilities in Coslada (Madrid), 600 square metres. 1978: Launch of the rejiband® tray. 1995: New facilities in Mejorada del Campo (Madrid), with a surface area of 6000 square metres. 1997: 5000 square meter expansion of the surface area at the Mejorada facilities. 1998: Launch of the pemsaband® tray. 2002 (September): Transfer to the new general facilities in Alcalá de Henares (Madrid), with a surface area of 45000 square metres and the possibility of doubling this capacity. 2003 (January): Opening of Pemsa UK Ltd., its first branch abroad, and the opening of two new offices. 2003 (May): Opening of the second branch abroad: Pemsa Portugal. 2004 (January): Enlargement of Production lines of Flexible Conduits. 2006 (May): Pemsa, Global Supplier of Cable Management. Expansion of product range of Conduits, Metallic rigid Conduits, Halogen Free Conduits. 2006 (June): Enlargement of Pemsa UK Store and Facilities 2006 (October): Purchase of Production line of Metallic Trays of PINAZO company, increasing the production capacity of pemsaband® line. 2008: Opening of new branches in France. 2009: 40th Anniversary of Pemsa. International presence: new branches abroad Pemsa has initiated a new stage of international expansion by direct presence, namely its own brand, which is integrated into the strategic plan of the company. This materialised in 2003 with the opening of three branches abroad: Pemsa UK, Pemsa Portugal and Pemsa France. Furthermore, Pemsa has already established a presence in a long list of countries throughout the five continents: Europe: Austria, Belgium, Cyprus, Denmark, Slovakia, France, Germany, Greece, Hungary, Ireland, Italy, Latvia, Poland, Sweden, the Czech Republic, the Netherlands and United Kingdom. America: Antilles, Chile, Costa Rica, Ecuador, El Salvador, Guatemala, Mexico, Nicaragua, Panama and USA. Asia: Dubai, Indonesia, Lebanon and Macau. Africa: Angola, Israel and Morocco; Oceania: New Zealand. 2 PEMSA-CAT 219-2-12-REV 27/11/09 11:30 Página 2 The metal tray and channel system that provides: Graphic labels Allow perfect identification of all elements of the rejiband® system. - Facilitate storage. - Allow product identification during the entire manufacturing process. A B - Include the following: 13-digit EAN bar code, reference number, the units it contains, type of finish and part dimensions. Protective packaging With heat-sealed film and identification label. It ensures maximum protection and perfect storage. B A CE Marking All products in this catalogue comply with CE directives. EAN code All products in this catalogue have been assigned their corresponding 13-digit, European bar code (EAN). 3 PEMSA-CAT 219-2-12-REV 27/11/09 11:30 Página 3 SUPPORTS New range of Reinforced Supports Pemsa introduce a new range of reinforced supports that unify the system connection for their rejiband® and pemsaband® trays and have the following advantages and new features: ADVANTAGES Click new and fast system, in the opposite direction to load forces, which guarantees the fixing of the tray to support and prevent their displacement. Unified Standard and Click range giving reduction in logistical references for the client. DISTINCT CHARACTERISTICS O PA N TA D TE Reinforced Strength D PA TE NTE The bracket has been designed with curves for greater strength and load bearing capacity. Click System Fixing pin for quickly securing the tray thus avoiding movement in any direction. Lateral Grooves PA TE D O PA Increases the load resistance of the bracket and reinforces the area supporting the tray. N TA D TE Detail of fixing Click System NTE Side Pressing Fully embossed side enhances the strength of the bracket and improves it’s load capacity. Back Pressing Embossed back increases the resistance of the bracket and prevents any bending. 4 4 Detail of fixing with Reinforced joint clamp 11:30 Página 4 D E NT E P New Range of Accessories pemsaband TE G 27/11/09 PA PEMSA-CAT 219-2-12-REV N DIN ® 90º Bend, Crossover, Tee, Side Entry, with their corresponding covers. New Parts, Inside and Outside Risers. Full range in all heights, 35, 60 and 85. Finishes P.G. and H.D.G. 90º Bend 300, height 60 Crossover 400, height 85 Click System Joint. There is no need to use joints to connect the accessories to the straight sections of pemsaband. Accesory Covers overlap on the tray, improving stiffness and tightness of the assembly. DN20 precut conduit exits. In heights 60 and 85 for installation fittings or glands of M20, PG11 or PG13. Inside Riser 5 PEMSA-CAT 219-2-12-REV 27/11/09 11:30 Página 5 The rejiband® BYCRO tray from PEMSA respects the environment and meets the RoHS standard. Pemsa has made a series of improvements to its rejiband® tray and its Bycro finish now offers the following advantages and features: Pemsa leads the market with its bichromed electro-galvanised rejiband® tray. Using the latest generation processes and products, the Bycro finish is fully compliant with the current RoHS legislation and RAEE directives. Pemsa is committed to protecting the environment by eliminating hexavalent chromium in its electro-galvanising plants. Its rejiband® trays are manufactured without products that are harmful, contaminating or have an adverse effect on the environment. The BYCRO finish still offers superb anti-corrosion protection. N TA PA TE D O PA TE D The BYCRO finish has a unique iridescent gold finish and superb technical properties. NTE The reference and coding systems for the product remain the same. Pemsa continues to lead the way with its rejiband® BYCRO tray which incorporates superior anticorrosion properties but is free of hexavalent chromium (Cr VI) and other heavy metals in compliance with 2002/95/CE RoHS. Pemsa continues to offer its customers a tray which guarantees greater safety, a better finish and an optimum price/quality ratio while protecting our environment. UL Classified rejiband® ELECTRICAL CONTINUITY GUARANTEED. This certification ensures, when using rejiband® basket, that the correct electrical continuity between trays exists which could, under certain circumstances, be used as a protective earth without using any additional protective conductor. Any protective conductor would connect all earthed points of an installation to the earth conductor, in order to eliminate the risks through indirect contact. The UL Classified mark, achieved by PEMSA, is the result of testing electrogalvanized rejiband® basket trays (35, 60 & 100mm flange) joined with the Reinforced Joint Clamp. It certifies that the requirements of the NEMA VE 1-2000 Metal Cable Tray Systems standards are met in accordance with the Canadian Electrical Code and the National Electrical Code, NEC. The value of the UL CLASSIFIED marking UL is one of the most renowned safety certification institutions worldwide. A UL marked product is an item that has been successfully tested by the UL in accordance with certain safety requirements. These tests ensure the use of this product does not bring any significant risk of fire, electric shock or any other linked danger. The safety requirements are equally met in the long term, since UL performs periodic checks and verifications at the manufacturer’s premises. 6 4 PEMSA-CAT 219-2-12-REV 27/11/09 11:30 Página 6 Fire Resistance 1000 ºC for 90 minutes. rejiband® basket tray has successfully exceeded the fire resistance tests defined by the German Standard DIN 4102-12 “Fire behaviour of building materials and elements, Fire resistance of electric cable systems required to maintain circuit integrity”, by withstanding 1000 ºC (1832ºF) temperature for 90 minutes, thus obtaining the E90 certification. In case of fire, rejiband® basket tray does not harm either the people or the installation itself (no fumes of toxic, corrosive or opaque nature at all), and ensures enough structural resistance and the power supply to the most critical systems (emergency lighting, fire detection, etc). For further information, consult pages 122 and 123. pemsa pro is the brand new software developed by Pemsa for the calculation and selection of Wire Mesh Tray, Steel Cable Tray and Channel Systems. This program allows the user to enter and define all parameters of the installation, and produces a choice of the most suitable trays, along with the required accessories, brackets, clamps, etc, in order to correctly configure a specific electrical installation. The cable type can also be chosen, thanks to the extensive data base of the main cable manufacturers. pemsa pro provides an easy and intuitive process, via a complete set of on-screen menus, that allows the user to enter all features of the installation. The software has two modes: Quick Calculation and Installation Calculation. The latter allows the breakdown of the project into floors, areas, sections and sub-sections in order to obtain a detailed definition of the installation. pemsa pro contains a vast collection of 3D tray assemblies, and a powerful tool for visualising these graphics. The views can be exported and inserted into any report or technical document. Last but not least, the software produces a complete report with all of the technical data and prices of the individual components required for the installation. 7 PEMSA-CAT 219-2-12-REV 27/11/09 11:30 Página 7 Pemsa Metal Trays and Channels rejiband ® The market-leading electrically welded steel mesh trays, with a safety edge that prevents personal injury and cable damage. Easy to handle, its "cut, bend and link" system allows easy adaptation to every installation and provides assembly time saving exceeding 30%. AS PA P D O PA TE ME It is lightweight, offers maximum ventilation and cleanliness, provides great strength and elasticity, and allows the addition of accessories during construction. N TA D TE NTE It has a very wide range of accessories: "Click," Omega and reinforced supports; fibre optic outlet systems, etc., as well as various finishes and materials: electrolytic zinc coating, hot-dip galvanising, AISI 304 and 316 stainless steel. pemsaband System ® A SM EP The in-line manufactured sheet metal tray using an automatic, integrated process starting with steel sheet rolls. Pemsa have optimized its range of metal tray by developing three different ranges of pemsaband® tray: pemsaband® SX, RX and LX pemsaband® SX Metal tray with the base embossed and perforated, It comes packaged to protect the corners and interior parts and also to facilitate handling and transport. The slotted perforations provide maximum strength for equal weight and thickness. pemsaband® SX has at a new joggled coupling system which increases the ease of connection between lengths and substantially reduces installation time. Thanks to this Click system, you do not need any coupler just two screws for assembly. The range of pemsaband® SX trays are designed and manufactured to the highest standards of quality, based on the product standard IEC 61537. This quality is confirmed by the N mark from AENOR, which guarantees all of its technical characteristics, and the E90 Fire Resistance Certification. Full range on heights 35, 60, 85 and 100. Widths of 100 to 600 mm. pemsaband® RX Perforated and solid tray manufactured from thicker material to withstand higher loads. High load capacity. Thickness = 1.5 mm. Available in 60, 85 and 100 depths. pemsaband® LX Perforated and embossed tray with Rapid Click Coupling System in 35 and 60 depths. Overall length is 3.05 metres. Furthermore, cables are protected. All this ranges of pemsaband®, longitudinal strength is increased through the shaped ends of the lateral edges. The fitted cover is secure and easy to install, without the need for clamps or bolts. The pemsaband® metal channel requires the use of a cover. This channel may be delivered with perforations, depending on the required IP. Perforated metal channel with cover: IP 2x. Solid metal channel with IP 4x cover. Comparison of the allowable load values of various cable trays Measurements of trays 8 PVC tray Rejiband tray Pemsaband SX tray 110 N/m 220 N/m 340 N/m 460 N/m 520 N/m 480 N/m 750 N/m 780 N/m 1150 N/m 1760 N/m 1040 N/m 1040 N/m PEMSA-CAT 219-2-12-REV 27/11/09 11:30 Página 8 P ME AS false floor DD IBANBAN REJREJI SA PEM DD IBANBAN REJREJI The rejiband® tray has a specific system for installation under false floors. This system allows quick, flexible and easy installation, thereby ensuring maximum cleanliness and ventilation. DD IBANBAN REJREJI SA PEM DD IBANBAN REJREJI SA DD SA PEM IBANBAN REJREJI SA PEM DD IBANBAN REJREJI PEM The rejiband® false floor is supplied with a complete range of specific supports and accessories for these types of installation. SA PEM Supports and structures They are basic in a tray installation. If they are not appropriate, the entire installation will fail. When selecting these elements, the load capacity of the support and the corrosion resistance are the main considerations. Pemsa has a complete range of installation solutions: • Supports for Ceiling / False Ceiling installations • Supports for Floor / False Floor installations. • Supports for Vertical / Horizontal Wall installations • Supports for Ceiling / Pendulum installations. • Supports for installations Outdoors / Indoors / In highly corrosive environments. • Structures for special installations. rejitech ® Installation on ceilings and false ceilings This is a specific tray for ceilings and false ceilings. It is a tray made of high-strength, electrically welded wire mesh, which provides multiple advantages. Its design prevents the accumulation of dust and dirt. It provides maximum cleanliness and faster and easier handling. N TA PA TE D O PA TE D The reduction in installation time exceeds 55%, given that it has been designed to be fastened to the ceiling by a single bolt. Its open design ensures lateral access to cables. NTE The savings in materials exceeds 40%, and given that it is manufactured in 2 metre lengths, transport is highly simplified and it can be easily transported in a small van. Furthermore, it provides for easy and effortless cable handling, given that the cables are completely visible. inducanal ® This is a metal channel of reduced size, appropriate for industrial installations. It has great impact resistance and resistance to temperature, and is manufactured with perforations that facilitate cable outlets. The Inducanal metal channel requires the use of the IP 2x cover. Characteristics and benefits of Pemsa Metal Trays • They eliminate the possibility of trays acting as fire propagation elements. • They eliminate the risk of inhalation of toxic gases or halogens. • They facilitate sufficient time and visibility in order to completely evacuate personnel, and facilitate access to fire sources for firemen. • They eliminate harmful effects to equipment, or electronic or computer circuits, due to the corrosive effect of smoke on these elements. IN BRIEF: The use of rejiband® and pemsaband® metal trays significantly improves the safety of owners and users of electrical installations. 9 PEMSA-CAT 219-2-12-REV 27/11/09 11:30 Página 9 rejiband® Cable Management System!! rejiband® FEATURES: Open Structure Superior Strength to Weight Ratio Inventory Management Design Criteria Fire Resistance E90 Adaptability BYCRO Coating www.pemsa-rejiband.com ER-0058/1997 10 cod. CYNW. E305934 PEMSA-CAT 219-2-12-REV 27/11/09 11:30 Página 10 rejiband® Wire mesh tray Wall installation Ceiling installation with rods Ceiling installation False floor installation Page 12 30-31 38-39 44-45 50 rejitech® Wire mesh tray false ceiling installation 52 pemsaband® system Index Steel cable tray The sheet metal tray with slotted perforations Pemsaband SX Pemsaband RX Pemsaband LX Wall installation Ceiling installation with rods Ceiling installation 56 60 65 67 80-81 86-87 92-93 inducanal® Reduced dimension metal channel 98 Supports & Structures 102 Screws 107 Technical information Recommendations for the correct installation of cable trays Technical information EN 61537 Choosing the right tray and support system Surface treatment to prevent corrosion Electrical continuity Earthing Electromagnetic Compatibility (CEM) Pemsa Metal Tray Systems: Behaviour in the event of fire Fire Resistance, E90 Certification Fire test in the tunnels of El Padrún 109 113 113 115 117 118 119 121 122 124 Index by products 126 Index by references 128 11 PEMSA-CAT 219-2-12-REV 27/11/09 11:30 Página 11 rejiband ® Mesh cable tray Corrosion (White) 500 440 400 350 - Enhanced Protection against Corrosion - Safety Edge - Chrome-VI free - Compliant with RoHS 2002/95/CE and WEEE 2002/96/CE ER-0058/1997 12 HOURS BYCRO Wire Mesh rejiband® Featuring: 300 290 250 200 150 100 50 0 E.G. E.B./BYCRO Laboratory Tests performed under ASTM B117 Standard proves the excellent behaviour of Pemsa BYCRO finish against corrosion. cod. CYNW. E305934 PEMSA-CAT 219-13-20-REV- 27/11/09 11:33 Página 1 The “Click” System for supports and accessories Exclusive, developed and patented by Pemsa. It brings quick fastening with no need for bolts or special tools, giving savings of up to 30%. Fit Bend Bend Fit It takes just one movement to fasten the item down securely. Quick fastening, with no bolts needed. CABLE OUTLET (page 28) FOOT (page 50) CLICK CONNECTOR (page 22) SUPPORT 60 (page 32) 13 PEMSA-CAT 219-13-20-REV- 27/11/09 11:33 Página 2 Rejiband 35 Length 3000 mm. N TA TE PA TE D O PA D E.G. NTE H.D.G. BYCRO S.S. 304 S.S. 316 A Ref. 100 60211100 0.65 60221100 0.65 60231100 0.70 60251100 0.65 200 60211200 1.01 60221200 1.01 60231200 1.08 60251200 300 60211300 1.38 60221300 1.38 60231300 1.46 60251300 400 60211400 1.77 60221400 1.77 60231400 2.02 60251400 /m Ref. /m Ref. /m /m mm2 m 60261100 0.65 2220 24 1.00 60261200 1.01 4900 18 1.36 60261300 1.38 7580 18 1.73 60261400 1.74 10200 12 Ref. /m Ref. Rejiband 60 Length 3000 mm. N TA TE PA TE D O PA D E.G. NTE H.D.G. BYCRO S.S. 304 S.S. 316 A Ref. 060 60212060 0.67 60222060 0.67 60232060 0.71 60252060 0.67 100 60212100 0.95 60222100 0.95 60232100 1.01 60252100 150 60212150 1.01 60222150 1.01 60232150 1.07 60252150 200 60212200 1.31 60222200 1.31 60232200 1.39 300 60212300 2.07 60222300 2.07 60232300 400 60212400 2.52 60222400 2.52 500 60212500 2.97 60222500 600 60212600 3.42 60222600 /m /m mm2 m 60262060 0.67 2410 24 0.94 60262100 0.94 4310 24 1.00 60262150 1.00 6900 24 60252200 1.30 60262200 1.30 9490 18 2.19 60252300 1.66 60262300 1.66 14200 12 60232400 2.66 60252400 2.02 60262400 2.02 19300 6 2.97 60232500 3.13 60252500 2.38 60262500 2.38 24400 6 3.42 60232600 3.61 60252600 2.74 60262600 2.74 29500 6 Ref. /m Ref. /m Ref. /m Ref. Rejiband 100 Length 3000 mm. N TA TE PA TE D O PA D E.G. NTE H.D.G. BYCRO S.S. 304 S.S. 316 A Ref. 200 60213200 2.06 60223200 2.06 60233200 2.17 60253200 1.65 60263200 1.65 17600 6 300 60213300 2.51 60223300 2.51 60233300 2.65 60253300 2.01 60263300 2.03 27300 6 400 60213400 2.96 60223400 2.96 60233400 3.12 60253400 2.37 60263400 2.37 37100 6 500 60213500 3.41 60223500 3.41 60233500 3.60 60253500 2.73 60263500 2.76 46800 6 600 60213600 3.86 60223600 3.86 60233600 4.07 60253600 3.09 60263600 3.12 56500 6 /m Ref. /m Ref. /m Ref. /m Ref. /m mm2 m Angle tray Rejitech (false-ceiling tray) BYCRO E.G. 100 60215020 /m A /m mm2 m 0.66 2500 16 Ref. 0.66 60225020 A O PA TE 14 /m 0.67 /m m 0.71 18 Ref. 60230000 S.S. 316 /m 0.67 /m m 0.67 18 Ref. 60260000 Length 3000 mm. Length 2000 mm. Weight in kilos Ref. 109 60250000 NTE Material: Steel Working temperature range: -50 ºC / 150 ºC H.D.G. S.S. 304 N TA D TE Ref. 109 60220000 D Ref. PA A BYCRO E.G. BYCRO P.G. H.D.G. S.S. Electrogalvanised UNE - EN 12329 Electrolytic Bichromate UNE - EN 12329 Pre-galvanised UNE - EN 10142 Hot-dip galvanised UNE - EN-ISO 1461 Passivated stainless steel AISI 304 or AISI 316 Página 3 Rejiband 35 MAXIMUM SAFE WORKING LOAD (Kg/m) 1 kg = 9.8 N E.G., BYCRO and H.D.G. STAINLESS STEEL Width: Width: 100 - 200 - 300 400 400 100 - 200 - 300 400 60 60 55 55 50 50 45 35 45 400 40 Kg/m 40 35 30 30 25 100 - 200 - 300 25 100 - 200 - 300 20 20 15 1,0 1,5 15 2,0 1,0 Distance between supports (meter) 1,5 MAXIMUM SAFE WORKING LOAD (Kg/m) E.G., BYCRO and H.D.G. 60 - 100 - 150 200 300 - 400 600 1 kg = 9.8 N STAINLESS STEEL Width: 500 60 - 100 - 150 200 - 300 - 400 600 110 180 100 90 600 100 300 - 400 80 70 500 Kg/m 120 60 80 50 200 - 300 - 400 60 200 40 40 60 - 100 - 150 1,5 20 2,0 1,0 Distance between supports (meter) 1,5 2,0 Distance between supports (meter) Rejiband 100 MAXIMUM SAFE WORKING LOAD ((Kg/m) E.G., BYCRO and H.D.G. 300 - 400 1 kg = 9.8 N STAINLESS STEEL Width: 200 30 60 - 100 - 200 20 1,0 200 300 - 400 500 - 600 500 - 600 130 290 120 260 110 500 - 600 230 100 210 90 180 Kg/m 500 - 600 80 300 - 400 150 300 - 400 70 120 60 200 90 200 50 60 1,0 1,5 Distance between supports (meter) 600 120 140 500 500 200 160 Width: 2,0 Distance between supports (meter) Rejiband 60 Width: Kg/m 11:33 Kg/m 27/11/09 2,0 Kg/m PEMSA-CAT 219-13-20-REV- 40 1,0 1,5 2,0 Distance between supports (meter) Values obtained from test according to the UNE-EN 61537 standard, with a safety coefficient of 170% without ever reaching the collapse point. Guaranteed only using our reinforced joint clamp. Tray section joints be situated at a support distance of between L/4 and L/5, L being the distance between supports. At completed tray extreme ends, tray support distance should be a maximum of 0.4L without any type of joint. 15 PEMSA-CAT 219-13-20-REV- 27/11/09 11:33 Página 4 MAKING ACCESSORIES ON SITE (bends, T-sections, etc.) cut - bend - join How to cut the grid Always use ASYMMETRICAL-CUT WIRE CUTTERS Cut as close as you can to where the horizontal and vertical rods cross each other, at the position shown: Avoid using parting tools to cut the grid It damages the rod’s protection The cutting leaves burrs ● It contaminates the surroundings ● The sparks can cause accidents ● It encourages rusting ● ● Cut position 16 Side cutting PEMSA-CAT 219-13-20-REV- 27/11/09 11:33 Página 5 WHAT YOU NEED Bolt cutters Reinforced joint clamp 450 68000058 1.6 Pack unit 1 600 68000059 2.8 1 0.027 PA 64010062 0.026 50 Ref. 64060061 /u 0.028 Pack unit 50 E.B. /u 0.010 H.D.G. Ref. 64030062 Part clamp Captive bolt 64010060 /u 0.01 D Ref. O D PA 64030060 NTE Splice plate 0.016 67010053 0.016 67030047 Central hanging plate M8 M10 M8 = ø9x16 M10 = ø11x18 M8 M10 Material: Steel Working temperature range: -50 ºC / +150 ºC Weight in kilos N= Load capacity per support in Newtons as per Standard UNE-EN 61537 50 Ref. 64060062 /u 0.01 Pack unit 50 Ref. /u 64020060 0.016 Pack unit 50 Ref. /u 64060060 0.017 Pack unit 50 E.B. /u 0.065 H.D.G. Ref. 0.009 Pack unit S.S. 316 /u E.G. Ref. 64020062 /u E.B. /u H.D.G. N TA Ref. S.S. 316 E.G. Ref. PA 0.026 Pack unit S.S. 316 /u E.G. Ref. TE 64020061 /u NTE Connector plate TE Ref. D O 64030061 /u E.B. /u H.D.G. Ref. D PA 64010061 N TA TE Ref. E.G. Ref. JUST 3 PARTS! ● Captive bolt ● Simplifies assembly ● 20% improvement in mechanical performance TE A Ref. 67020053 /u 0.065 Pack unit 10 S.S. 316 /u 0.069 E.G. Ref. 67060053 /u 0.064 Pack unit 10 E.B. Type A Ref. 9x16 67010046 0.032 67020046 0.029 20 11x18 - - 67020146 0.028 20 /u H.D.G. Ref. /u Pack unit S.S. 316 Type A Ref. 9x16 67030046 0.031 67060046 0.030 20 11x18 67030146 0.032 67060146 0.032 20 /u Ref. /u E.G. E.B. Electrogalvanised UNE - EN 12329 Electrolytic Bichromated UNE - EN 12329 H.D.G. S.S. Hot-dip galvanised UNE - EN-ISO 1461 Passivated stainless steel AISI 304 or AISI 316 Pack unit 17 PEMSA-CAT 219-13-20-REV- 27/11/09 11:33 Página 6 Examples of assembly 90º BENDS CUT For 100-600 mm wide trays A B N 100 300 100 150 400 200 200 400 200 300 500 300 400 600 400 500 700 500 600 800 600 Reinforced joint clamp (page 22) For 60 mm wide trays 50 0 1 260 0 CU 10 T Reinforced joint clamp (page 22) 18 PEMSA-CAT 219-13-20-REV- 27/11/09 11:33 Página 7 90º BENDS For 100-150 mm wide trays CU T Reinforced joint clamp (page 22) For 200-600 mm wide trays CU T A B N 200 525 100 300 625 200 400 725 300 500 825 400 600 925 500 Reinforced joint clamp (page 22) Central hanging plate x 2 (page 17) DIN 603 M6x20 screw (page 107) M6 nut (page 107) 19 PEMSA-CAT 219-13-20-REV- 27/11/09 11:33 Página 8 90º BENDS For 300-600 mm wide trays L CU T X ADJUST A B L X 300 570 1300 5 400 840 1700 7 500 920 2100 9 Part clamp (page 24) 600 1300 2300 10 Splice plate (page 24) Reinforced joint clamp (page 22) LEVEL CHANGE CU T BEND 20 PEMSA-CAT 219-21-37-REV 27/11/09 11:36 Página 1 CUT REDUCER Reinforced joint clamp (page 22) Part clamp (page 24) Splice plate (page 24) T-JOINTS CU T Reinforced joint clamp (page 22) 21 PEMSA-CAT 219-21-37-REV 27/11/09 PARTS 11:36 Página 2 (for Rejiband fitting) Reinforced joint clamp E.G. E.B. Ref. 64010061 Ref. /u Pack unit PA TE 0.027 64020061 0.026 50 D O PA /u N TA D TE NTE H.D.G. S.S. 316 Ref. /u 64030061 0.026 Ref. /u 64060061 Pack unit 0.028 50 JUST 3 PARTS¡ ● Captive bolt ● Simplifies assembly ● 20% improvement in mechanical performance Click connector E.G. Ref. D AN JIB TY RE CURI SE PA TE D O PA N TA D TE NTE Ref. /u 64010020 ● ● ● ● E.B. 0.072 /u 64020030 Pack unit 0.072 25 Quick fitting No bolts No special tools Electrical continuity guaranteed Side joint-plate E.G. Ref. 64010041 E.B. /u 0.048 H.D.G. Ref. 64030041 Wire end cap Ref. 64020041 /u Pack unit 0.048 50 S.S. 316 /u 0.05 Ref. 64060041 /u Pack unit 0.048 50 BLACK POLYETHYLENE Ref. 68000049 /u 0.001 Pack unit 100 Working temperature range: -50 ºC / +60 ºC Material: Steel Working temperature range: -50 ºC / +150 ºC Weight in kilos 22 E.G. E.B. H.D.G. S.S. 316 Electrogalvanised UNE - EN 12329 Bichromate Electrolytic zinc-plating UNE - EN 12329 Hot-dip galvanised UNE - EN-ISO 1461 Passivated stainless steel AISI 316 PEMSA-CAT 219-21-37-REV 27/11/09 11:36 Página 3 Examples of assembly CONNECTORS NEEDED EVERY 3 METERS WIDE 060 100 150 200 300 400 500 600 2 2 2 2+1 2+1 2+2 2+2 2+2 Wire end cap (page 22) CONNECTORS NEEDED EVERY 3 METERS WIDE 100 150 200 300 400 500 600 NER SAFE FAS T E T Y 2 2 2+1 2+1 2+2 2+2 2+2 23 PEMSA-CAT 219-21-37-REV 27/11/09 11:36 Página 4 Splice plate E.G. Ref. E.B. /u 67010053 0.065 H.D.G. Ref. Part clamp 0.069 E.G. Ref. Captive bolt Ref. 67060053 /u 0.064 Pack unit 10 0.016 Ref. 64020060 /u 0.016 Pack unit 50 N TA O PA 10 E.B. /u 64010060 0.065 Pack unit D TE 67020053 /u S.S. 316 /u 67030047 Ref. H.D.G. D PA TE S.S. 316 NTE Ref. 64030060 /u 0.016 Ref. 64060060 /u 0.017 Pack unit 50 Earth terminal BRASS Suitable for cable sizes 16-35 mm2 Ref. 68000032 /u 0.024 Pack unit 20 New design. More economical. Less weight. Zinc paint spray Ref. Contents: 400 ml. 68000052 /u 0.52 Pack unit 1 Store and transport temperature range: -20 ºC / +40 ºC Working temperature: -50 ºC / +150 ºC Material: Steel Working temperature range: -50 ºC / +150 ºC Weight in kilos 24 E.G. E.B. H.D.G. S.S. 316 Electrogalvanised UNE - EN 12329 Electrolytic Bichromate UNE - EN 12329 Hot-dip galvanised UNE - EN-ISO 1461 Passivated stainless steel AISI 316 PEMSA-CAT 219-21-37-REV 27/11/09 11:36 Página 5 Examples of assembly CONNECTORS NEEDED EVERY 3 METERS WIDE 100 150 200 300 400 500 600 4 4 4 6 8 8 8 2 2 2 2+1 2+2 2+2 2+2 CONNECTORS NEEDED FOR EACH SUPPORT WIDE 100 150 200 300 400 500 600 1 1 2 2 2 3 3 EARTH CONNECTION Suitable for cable sizes 16-35 mm2 25 PEMSA-CAT 219-21-37-REV 27/11/09 11:36 Página 6 Rejifix Rejifix • Inexpensive and reusable. • Allows contignous cable placement. • No screws or other fixing elements are required. • Manufactured using fire retarding ABS plastic material. Colour Ref. nº Wide m/roll /u Pack unit 0.14 89011000 BLACK 10 mm 25 m 1 Working temperature range: -40 ºC / +60 ºC Suitable for installations: voice, data, fibre optic... Fixing support for Rejiband ABS Ref. Pack unit Working temperature range: -5 ºC / +90 ºC 20 /u 68000010 0.008 For fastening the ties or cleats that hold the cables supported on the Rejiband wire mesh tray. Rejiband box support PLASTIC Ref. • Inexpensive. • Hand installation by preassure. • No accessories required. • Efficiently isolated so as not to permit electric contact between box and tray. /u 68000040 0.01 Pack unit 20 Working temperature range: -15 ºC / +60 ºC Press Fit Identification plate No text - for marking by the user PLASTIC Working temperature range: -5 ºC / +105 ºC 26 Ref. 89010000 /u 0.01 Pack unit 50 PEMSA-CAT 219-21-37-REV 27/11/09 11:36 Página 7 Examples of assembly Rejifix IDENTIFICATION PLATE: TO USE FOR IDENTIFICATION pemsa es abl c a dat ce-/3 i ) o V e7 any p n i 7 m L nt o Pla (C Press Fit REJIBAND BOX SUPPORT 27 PEMSA-CAT 219-21-37-REV 27/11/09 11:36 Página 8 Cover P.G. 3m length /m m 060 73021060 0.47 73031060 0.62 73061060 0.62 24 100 73021100 0.74 73031100 0.84 73061100 0.85 24 150 73021150 1.02 73031150 1.14 73061150 1.16 12 200 73021200 1.30 73031200 1.60 73061200 1.48 12 300 73021300 2.11 73031300 2.30 73061300 2.11 6 400 73021400 2.74 73031400 3.68 73061400 2.74 6 500 73021500 4.22 73031500 4.54 73061500 3.37 6 600 73021600 5.01 73031600 5.39 73061600 4.00 6 A Ref. 25 67020610 0.26 67030610 0.30 50 67020611 0.38 67030611 0.43 80 67020612 0.53 67030612 0.60 /m Ref. P.G. E N TA /m H.D.G. /m Ref. S.S. 316 Ref. /m Ref. /m m 67060610 0.26 60 67060611 0.38 48 67060612 0.53 36 D PA TE D O PA S.S. 316 Ref. Divider plate T H.D.G. A NTE A 3m length The PG finish on the 25, 50 and 80 flange comes packaged for correct storage. HD and stainless steel finishing is supplied in plastic tensed strip packaging for easy storage. Identification label PLASTIC LABEL PA /u 68000020 0.002 Pack unit 50 D O PA TE Ref. Working temperature range: -20 ºC / +60 ºC N TA D TE NTE Connector plate E.G. Ref. 64010062 E.B. 0.01 H.D.G. Ref. /u /u 64020062 0.009 Pack unit Ref. 50 64030062 S.S. 316 /u 0.01 Ref. 64060062 /u 0.01 Pack unit 50 Universal bracket P.G. Ref. 62026011 H.D.G. /u 0.169 S.S. 316 Ref. /u 62036011 0.182 Ref. 62066011 /u 0.176 Pack unit 10 For fixing boxes, use M5 bolts Gland bracket Data outlet Press Fit For conduit size: M20 PG 13 M20 PG 16 M25 PG 21 Weight in kilos 28 10 E.G. E.B. P.G. H.D.G. S.S. 316 TE N TA TE D 0.063 Pack unit O Material: Steel Working temperature range: -50 ºC / +150 ºC 67020040 POLYPROPYLENE /u D 0.063 Ref. PA 67010040 E.B. /u PA E.G. Ref. Press Fit NTE Ref. 67020039 Electrogalvanised UNE - EN 12329 Electrolytic Bichromate UNE - EN 12329 Pre-galvanised UNE - EN 10142 Hot-dip galvanised UNE - EN-ISO 1461 Passivated stainless steel AISI 316 /u 0.011 Pack unit 10 PEMSA-CAT 219-21-37-REV 27/11/09 11:36 Página 9 Examples of assembly 3m length BEND Divider plate (page 28) Identification label Fastest Mounting Identification label! BEND 29 PEMSA-CAT 219-21-37-REV 27/11/09 11:36 Página 10 Wall assembly Horizontal Side support 60 Mini Universal Bracket Omega Bracket Omega bracket on channel 250 N 500 N 580/1660 N 580/1660 N page 32 page 32 page 34 page 34 150 page 34 page 34 200 page 34 page 34 300 page 34 page 34 Admissible load ❶ TRAY WIDTH: 060 100 page 32 400 500 600 ❶ Values obtained from test according to the UNE-EN 61537 standard, with a safety coefficient of 170% without ever reaching the collapse point. Guaranteed only for our hanger with security plug and supports reinforced with the PEMSA structural reinforcement 30 PEMSA-CAT 219-21-37-REV 27/11/09 11:36 Página 11 Horizontal Rejiband Security Pemsa Inclined Rejiband Security Pemsa Medium Duty Cantilever Medium Duty Cantilever on channel 1180/2530 N 1180/2530 N Rejiband Security Vertical Pemsa Adjustable Medium Duty Cantilever 1210/2060 N Mini Universal Bracket Stand off Bracket 500 N 1000 N REINFORCED SUPPORTS GREATER LOAD-BEARING CAPACITY page 36 page 36 page 36 page 32 page 36 page 36 page 36 page 32 page 36 page 36 page 36 page 32 page 36 page 36 page 36 page 32 page 36 page 36 page 36 page 32 page 36 page 36 page 36 page 32 page 36 page 36 page 36 page 32 NOTE!! E FIT SUITABL W E ALL! PLUGS IN TH 31 PEMSA-CAT 219-21-37-REV 27/11/09 11:36 Página 12 Side support 60 N E.G. AxB E.B. Ref. 250 104x30 N /u 62011060 0.041 250 104x30 0.04 Ref. Pack unit /u 62061060 0.041 25 0 Rejiband 60x6 D PA D O PA 25 Essential for N TA TE 0.041 S.S. 316 /u 62031060 Pack unit. /u 62021060 H.D.G. AxB Ref. TE Ref. NTE Mini universal bracket N P.G. AxB Ref. 510 65x87 Stand off bracket N 62026010 Material: Steel Working temperature range: -50 ºC / +150 ºC Weight in kilos N= Load capacity per support in Newtons as per Standard UNE-EN 61537 32 0.088 P.G. A Ref. 1000 H.D.G. /u Ref. 62036010 S.S. 316 /u 0.098 H.D.G. /u Ref. Ref. /u 62066010 0.092 Pack unit 10 S.S. 316 /u Ref. /u Pack unit 180 67030539 0.17 67030541 0.24 67060541 0.13 10 350 67030540 0.32 67030542 0.35 67060542 0.21 10 E.G. E.B. P.G. H.D.G. S.S. Electrogalvanised UNE - EN 12329 Electrolytic Bichromate UNE - EN 12329 Pre-galvanised UNE - EN 10142 Hot-dip galvanised UNE - EN-ISO 1461 Passivated stainless steel AISI 316 PEMSA-CAT 219-21-37-REV 27/11/09 11:36 Página 13 Examples of assembly HORIZONTAL VERTICAL Part clamp (page 24) 33 PEMSA-CAT 219-21-37-REV 27/11/09 11:36 Página 14 Omega Click bracket • Including new Omega plug (preassembled) and new Omega protector • Guarentees and improves the performance of the OMEGA SUPPORTS • Makes feating easier and aids proper fitting of the support. N P.G. AxB H.D.G. Ref. /u Ref. /u Pack unit 1180 100x145 62023103 0.27 62033103 0.28 5 1040 150x145 62023153 0.31 62033153 0.32 5 1150 200x145 62023203 0.48 62033203 0.51 5 870 300x145 62023303 0.62 62033303 0.65 5 580 400x145 62023403 0.75 62033403 0.79 5 Working temperature range: -5 ºC / +90 ºC Omega bracket • Including new Omega plug (preassembled) and new Omega protector • Guarentees and improves the performance of the OMEGA SUPPORTS • Makes feating easier and aids proper fitting of the support. P.G. AxB N H.D.G. Ref. /u Ref. S.S. 316 /u (PGHDG) Ref. N /u (S.S.) Pack unit 100x145 62021103 0.26 62031103 0.28 1180 62061103 0.35 1660 5 150x145 62021153 0.30 62031153 0.32 1040 62061153 0.40 1390 5 200x145 62021203 0.47 62031203 0.50 1150 62061203 0.47 1130 5 300x145 62021303 0.60 62031303 0.63 870 62061303 0.60 860 5 400x145 62021403 0.73 62031403 0.77 580 62061403 0.73 590 5 Working temperature range: -5 ºC / +90 ºC Material: Steel Working temperature range: -50 ºC / +150 ºC Weight in kilos N= Load capacity per support in Newtons as per Standard UNE-EN 61537 34 P.G. Pre-galvanised UNE - EN 10142 H.D.G. Hot-dip galvanised UNE - EN-ISO 1461 PEMSA-CAT 219-21-37-REV 27/11/09 11:36 Página 15 Examples of assembly Wall mounting Channel mounting Channel mounting (Turn and click) M10x35 screw (page 107) Washer 10 (page 107) Heavy duty channel (page 104) Channel nut M10 (page 104) Safety plug Allen screw M10x20 (page 107) Wall plug M10 M10x35 screw (page 107) Click System Fit Economy Speed Fit Bend Bend 35 PEMSA-CAT 219-21-37-REV 27/11/09 11:36 Página 16 Medium Duty Cantilever P.G. 30 35 P.G. AxB N Ref. NEW! A B PA TE Pack unit 100x54 62025103 0.18 2530 4 150x54 62025153 0.23 1890 4 200x54 62025203 0.38 1560 4 300x54 62025303 0.53 1240 4 400x92 62025403 0.76 1220 4 500x92 62025503 0.93 1210 4 600x92 62025603 1.09 1200 4 D O PA 7X20 D T E N TA /u NTE Medium Duty Cantilever 40 H.D.G. 12X16 AxB 30 30 H.D.G. N Ref. NEW! A B /u S.S. 316 Ref. N /u Pack unit 100x50 62035103 0.23 2060 62065103 0.19 1930 4 150x50 62035153 0.28 1870 62065153 0.24 1720 4 200x50 62035203 0.33 1780 62065203 0.28 1610 4 300x50 62035303 0.42 1690 62065303 0.37 1500 4 400x77 62035403 0.77 1840 62065403 0.70 1580 4 500x77 62035503 1.92 1640 62065503 0.84 1380 4 600x77 62035603 1.06 1210 62065603 0.98 1180 4 35 PA TE D O PA 7X20 N TA D TE NTE Heavy Duty Cantilever 12X16 40 AxB 30 H.D.G. N Ref. 30 A 117 NEW! B /u Pack unit 300x77 63033303 0.79 2490 4 400x77 63033403 0.99 2160 4 500x77 63033503 1.19 2000 4 600x77 63033603 1.38 1840 4 7X20 35 O PA N TA D TE D PA TE NTE Adjustable Medium Duty Cantilever Ø12 46 AxB 47 104 A NEW! B PA TE 7X20 35 Pack unit 100x74 62037103 0.54 2060 4 150x74 62037153 0.59 1870 4 200x74 62037203 0.63 1780 4 300x74 62037303 0.73 1690 4 400x74 62037403 1.08 1840 4 500x74 62037503 1.23 1640 4 600x74 62037603 1.37 1210 4 Delivered unassembled. All pieces included. NTE Material: Steel Working temperature range: -50 ºC / +150 ºC Weight in kilos N= Load capacity per support in Newtons as per Standard UNE-EN 61537 36 N /u D O PA N TA D TE H.D.G. Ref. P.G. H.D.G. S.S. Pre-galvanised UNE - EN 10142 Hot-dip galvanised UNE - EN-ISO 1461 Passivated stainless steel AISI 316 PEMSA-CAT 219-21-37-REV 27/11/09 11:36 Página 17 Examples of assembly SUPPORTS 6 3 5 4 Wall mounting 1 5 4 2 Channel assembly 1 Medium Duty Cantilever H.D.G. 2 Medium Duty Cantilever P.G. 3 Heavy duty channel 41x21 G.C. (page 104) 4 Hexagonal screw M10 (page 107) 5 Washer M10 (page 107) 6 Channel nut M10 (page 104) DISTINCT CHARACTERISTICS Reinforced Strength The bracket has been designed with curves for greater strength and load bearing capacity Click System Fixing pin for quickly securing the tray thus avoiding movement in any direction. Detail of fixing Click System Lateral Grooves Increases the load resistance of the bracket and reinforces the area supporting the tray. Side Pressing Fully embossed side enhances the strength of the bracket and improves it’s load capacity. Back Pressing Embossed back increases the resistance of the bracket and prevents any bending. Detail of fixing with Reinforced joint clamp 37 PEMSA-CAT 219-38-44-REV 27/11/09 11:38 Página 1 Fitting to ceiling with threaded rods Admissible load ❶ 250 N 890 N 890 N 690 N 100 page 40 page 40 page 40-42 150 page 40 page 40 page 40-42 200 page 40 page 40 page 40-42 TRAY WIDTH: 060 page 40 300 400 500 600 + EASY CABLE LAYING ❶ Values obtained from test according to the UNE-EN 61537 standard, with a safety coefficient of 170% without ever reaching the collapse point. Guaranteed only for our hanger with security plug and supports reinforced with the Pemsa structural reinforcement 38 PEMSA-CAT 219-38-44-REV 27/11/09 11:38 Página 2 with threaded rods 690 N 800 N 1760/2000 N 1760/3320 N 4310/4890 N page 40-42 page 40-42 page 40-42 page 40-42 page 40-42 page 40-42 page 40-42 page 40-42 page 40-42 page 40-42 page 40-42 page 40-42 page 40-42 page 40-42 page 40-42 page 40-42 page 40-42 + ASSEMBLY TIME SAVING NOTE!! E FIT SUITABL E WALL! PLUGS IN TH 39 PEMSA-CAT 219-38-44-REV 27/11/09 11:38 Página 3 Side support 60 Rod Connector M8 N TA PA TE D O PA TE D Essential for Rejiband 60x60 NTE E.B. N AxB E.G. Ref. 250 104x30 N AxB /u 62011060 0.041 Ref. /u Pack unit 0.041 4000 67020067 /u Pack unit 0.016 50 25 S.S. 316 /u 62031060 Ref. 62021060 H.D.G. Ref. 250 104x30 N E.B. 0.04 Ref. /u 62061060 Pack unit 0.04 25 Threaded rod M6/M8/M10 N E.G. AxB Ref. M6 E.B. /u Ref. /u Pack unit 67010140 0.12 67020140 0.12 - - 50 1890 M6x1000 67010141 0.24 67020141 0.24 67060141 0.24 50 N AxB E.B. Ref. /u Pack unit 67020044 0.16 67060044 0.16 50 4000 M8x1000 67020045 0.32 67060045 0.32 50 M10 5000 M10x1000 67020145 0.49 67060145 0.49 50 Type A N M8 M10 M8 = ø9x16 M10 = ø11x18 E.G. Ref. E.B. /u Ref. /u Pack unit 9 700 67010046 0.032 67020046 0.029 20 11 700 - - 67020146 0.028 20 Type A N 9 700 67030046 0.031 67060046 0.030 20 11 700 67030146 0.032 67060146 0.032 20 M8 M10 Click Central Suspension S.S. 316 /u M8 4000 M8x500 Central hanging plate Type A A H.D.G. Ref. N S.S. 316 /u E.G. Ref. M6 6.2x15.5 890 M8 8.2x15.5 890 M10 10.2x15.5 890 Ref. /u Pack unit E.B. /u Ref. /u Pack unit 67010143 0.045 67020143 0.045 20 67010043 0.044 67020043 0.044 20 67010243 0.044 67020243 0.044 20 N TA D Type PA TE D O PA Ref. 1890 M6x500 Ref. TE S.S. 316 /u NTE A Used for hanging wire mesh tray from the ceiling, it is suitable por Rejiband trays in 100, 150 and 200 widths. N H.D.G. Ref. M6 6.2x15.5 890 M8 8.2x15.5 890 M10 10.2x15.5 890 S.S. 316 /u Ref. /u Pack unit 67030143 0.047 67060143 0.044 20 67030043 0.047 67060043 0.044 20 67030243 0.047 67060243 0.044 20 Variable ceiling rod bracket Ceiling bracket Use with s M8/M10 rod H.D.G. N P.G. Ref. 67030060 Ref. /u 0.094 Material: Steel Working temperature range: -50 ºC / +150 ºC Weight in kilos N= Load capacity per support in Newtons as per Standard UNE-EN 61537 40 Pack unit 10 1275 E.G. E.B. P.G. H.D.G. S.S. 67030061 /u 0.15 Pack unit 1 Electrogalvanised UNE - EN 12329 Bichromate Electrolytic zinc-plating UNE - EN 12329 Pre-galvanised UNE - EN 10142 Hot-dip galvanised UNE - EN-ISO 1461 Passivated stainless steel AISI 316 PEMSA-CAT 219-38-44-REV 27/11/09 11:38 Página 4 Examples of assembly Position Bend Only 1 part with 2 nuts! MAX. - 700 N Click central suspension (page 40) Threaded rod M8 (page 40) M10x35 screw (page 107) Central hanging plate (page 40) Variable ceiling rod bracket (page 40) Beam clamp hanging assembly (p. 42) Threaded rod M-10 Fitting to ceiling Side support 60 (page 40) 41 PEMSA-CAT 219-38-44-REV 27/11/09 11:38 Página 5 Mesh channel N P.G. A Ref. H.D.G. /u Ref. /u Pack unit 1 rod 2 rods 3320 4890 200 63022203 0.23 63032203 0.24 10 2540 4740 300 63022303 0.33 63032303 0.34 10 1760 4600 400 63022403 0.42 63032403 0.45 10 - 4460 500 63022503 0.52 63032503 0.55 10 - 4310 600 63022603 0.62 63032603 0.65 10 Working Temperatura with Safety Plug: -5 ºC / +105ºC Safety plug PA TE D O PA N TA D TE NTE incluided for better performance on widths 200-400 Mesh Click channel PATENTEDPATENTADO N P.G. A H.D.G. Pack unit 1 rod 2 rods 3320 4890 200 63021203 0.23 63031203 0.25 10 2540 4740 300 63021303 0.34 63031303 0.35 10 1760 4600 400 63021403 0.43 63031403 0.45 10 - 4460 500 63021503 0.53 63031503 0.56 10 - 4310 600 63021603 0.63 63031603 0.66 10 Ref. /u Ref. /u Working Temperatura with Safety Plug: -5 ºC / +105ºC With safety plug incluided! Beam clamp hanging assembly (*) The Loads depends of type of assembly. Please view the below pictures. NS NS NS KG KG 2000 N 950 N 25 KG 2000 N ≥ 30º 45º E.B. N Ref. (*) 67020048 /u 0.34 Pack unit NS KG NS 1 2500 N 700 N Horizontal angle hanger NS KG KG 800 N Vertical angle hanger A A PASSIVATED N A Ref. 690 /u PASSIVATED Pack unit 1.5-5 68000721 0.05 100 4-10 68000722 0.05 100 Material: Steel Working temperature range: -50 ºC / +150 ºC Weight in kilos N= Load capacity per support in Newtons as per Standard UNE-EN 61537 42 N A Ref. 690 /u Pack unit 1.5-5 68000731 0.04 100 4-10 68000732 0.04 100 E.B. Bichromate Electrolytic zinc-plating UNE - EN 12329 P.G. Pre-galvanised UNE - EN 10142 H.D.G. Hot-dip galvanised UNE - EN-ISO 1461 PEMSA-CAT 219-38-44-REV 27/11/09 11:38 Página 6 Examples of assembly (A) Fitting with one rod LAYING + EASY CABLE ME SAVING + ASSEMBLY TI NOTE! With safety plug included! (B) Fitting with two rods Threaded rod M10 (page 40) Safety plug Hexagonal nut M10+washer (page 107) Mesh Click channel (page 42) Threaded rod M8 (page 40) Mesh Click channel (page 42) Hexagonal nut M8 (page 107) Cost comparison (A) (B) 40 100 43 PEMSA-CAT 219-38-44-REV 27/11/09 11:38 Página 7 Fitting to ceiling Omega System ❶ Bending Moment 1 ❷ Bending Moment 2 ❷ Vertical Force 320/960 N 2100/3810 N 3370 N 3370 N - 120 Nm 410 Nm 410 Nm - 110 Nm 150 Nm 150 Nm 100 page 46 page 34-36-46 page 34-36-46 page 34-36-46 150 page 46 page 34-36-46 page 34-36-46 page 34-36-46 200 page 46 page 34-36-46 page 34-36-46 page 34-36-46 300 page 46 page 34-36-46 page 34-36-46 page 34-36-46 400 page 46 TRAY WIDTH: 500 600 ANGLE TRAY ❶ Values obtained from test according to the UNE-EN 61537 standard, with a safety coefficient of 170% without ever reaching the collapse point. Guaranteed only for our hanger with security plug and supports reinforced with the Pemsa structural reinforcement 44 PEMSA-CAT 219-45-52-REV 27/11/09 11:40 Página 1 reinforced pendant bracket 3780 N 3780 N 4270 N 7270 N 700 N 360 Nm 360 Nm 930 Nm 930 Nm - 430 Nm 430 Nm 730 Nm 730 Nm - REINFORCED SUPPORTS GREATER LOAD-BEARING CAPACITY page 36-48 page 36-48 page 36-48 page 36-48 page 36-48 page 36-48 page 36-48 page 36-48 page 36-48 page 36-48 page 36-48 page 36-48 page 36-48 page 36-48 page 36-48 page 36-48 page 36-48 page 36-48 page 36-48 page 36-48 page 36-48 page 36-48 page 48 ❷ Values obtained in accordance with International Standard UNE - EN 61537 (Section H) relating to the information for safe installation of trays with horizontal supports. For further information please contact PEMSA. * Bending moment 1 : Resulting bending moment on ceiling plane. * Bending moment 2 : Resulting bending moment from cantilever bracket. NOTE!! E PLUGS FIT SUITABL L! IN THE WAL 45 PEMSA-CAT 219-45-52-REV 27/11/09 11:40 Página 2 Omega ceiling bracket D NTE PA N H.D.G. Ref. O PA TE P.G. A N TA D TE /u Ref. S.S. 316 /u (PGHDG) Ref. N /u (S.S.) Pack unit 100 62022103 0.42 62032103 0.44 760 62062103 0.56 940 4 150 62022153 0.62 62032153 0.66 960 62062153 0.62 780 4 200 62022203 0.67 62032203 0.72 800 62062203 0.69 630 4 300 62022303 0.82 62032303 0.86 650 62062303 0.82 470 4 400 62022403 0.94 62032403 0.99 340 62062403 0.94 320 4 • Including Omega plug (preassembled) and Omega protector • Guarentees and improves the performance of the OMEGA SUPPORTS • Makes feating easier and aids proper fitting of the support. Omega Click ceiling bracket N P.G. AxB Ref. H.D.G. /u Ref. /u Pack unit 760 100 62029103 0.42 62039103 0.45 4 960 150 62029153 0.63 62039153 0.67 4 800 200 62029203 0.70 62039203 0.74 4 650 300 62029303 0.84 62039303 0.88 4 340 400 62029403 0.92 62039403 1.02 4 Including Omega plug (preassembled) and Omega Protector. Click system. Fast fixing of tray without the need of bolts Omega pendant bracket P.G. A Ref. H.D.G. /u Ref. S.S. 316 /u Ref. 46 Pack unit 300 62021303 0.42 62031303 0.45 62061303 0.45 5 400 62021403 0.63 62031403 0.67 62061403 0.67 5 500 62021503 0.70 62031503 0.74 62061503 0.74 5 600 62021603 0.84 62031603 0.88 62061603 0.88 5 Including Omega plug (preassembled) and Omega Protector. Material: Steel Working temperature range: -5 ºC / +90 ºC Weight in kilos N= Load capacity per support in Newtons as per Standard UNE-EN 61537 /u P.G. H.D.G. S.S. Pre-galvanised UNE - EN 10142 Hot-dip galvanised UNE - EN-ISO 1461 Passivated stainless steel AISI 316 PEMSA-CAT 219-45-52-REV 27/11/09 11:40 Página 3 Examples of assembly 4 100/400 LOAD 300/600 According to Omega Ceiling bracket table. 100/400 S.S. 316 2100 3810 Bending Moment 1 120 110 Bending Moment 2 110 130 300/600 P.G., H.D.G. Vertical Force 100/400 S.S. 316 3370 3370 Bending Moment 1 410 410 Bending Moment 2 150 190 300/600 P.G., H.D.G. Vertical Force 100/400 M10x35 screw+washer (page 107) M10x20 screw+washer+nut (page 107) M10x60 screw+washer+nut (page 107) Safety plug Omega bracket 100 (page 34) Omega Click bracket 100/300 (page 34) 100/400 100/400 P.G., H.D.G. S.S. 316 Vertical Force 3370 3370 Bending Moment 1 410 410 Bending Moment 2 150 190 47 PEMSA-CAT 219-45-52-REV 27/11/09 11:40 Página 4 Heavy duty pendant drop N BM 1 BM 2 A H.D.G. Ref. /u Pack unit 3780 360 430 500 67030660 1.51 1 3780 360 430 1000 67030661 2.47 1 N BM 1 BM 2 A Double heavy duty pendant drop 150 80 A H.D.G. Ref. /u Pack unit 4270 930 730 500 67030662 2.48 1 4270 930 730 1000 67030663 4.40 1 N BM 1 BM 2 A Heavy duty pendant channel P.G. Ref. 360 430 500 67030646 0.87 1 3780 360 430 1000 67030647 1.76 1 Angle tray fastener E.B. P.G. 67030645 /u 0.62 Pack unit 1 M10x20 hexagonal cone point screw not included. Angle tray BYCRO H.D.G. Ref. 60220000 /u 0.67 Ref. 60230000 Ref. 67020051 Ref. Length: 3000 mm Material: Steel Working temperature range: -50 ºC / +150 ºC Weight in kilos N= Load capacity per support in Newtons as per Standard UNE-EN 61537 60260000 /u m 0.67 18 /u 0.18 Pack unit 10 S.S. 304 /u 0.71 Ref. 60250000 S.S. 316 48 Pack unit 3780 Heavy duty pendant boss Ref. /u BYCRO/E.B. Electrolytic Bichromated UNE - EN 12329 P.G. Pre-galvanised UNE - EN 10142 H.D.G. Hot-dip galvanised UNE - EN-ISO 1461 S.S. Passivated stainless steel AISI 316 /u m 0.67 18 PEMSA-CAT 219-45-52-REV 27/11/09 11:40 Página 5 Examples of assembly Fit every 1 m. M8x60 screw+nut+serrated washer (page 107) M10x20 screw (page 107) Channel nut (page 104) M10x20 hexagonal cone point screw (page 107) 49 PEMSA-CAT 219-45-52-REV 27/11/09 11:40 Página 6 rejiband false floor D AN IB EJ R ® D AN IB EJ R SA M PE D AN IB EJ R SA M PE D AN IB EJ R SA M PE D AN IB EJ R SA M PE D AN IB EJ R SA M PE RE JIB AN D SA M PE Rejiband 35 Floor foot POLYSTYRENE Ref. 68000060 Rejiband 60 Pack unit /u 0.02 100 Working temperature range: -5 ºC / +60 ºC V2 according to UL 94 O PA N TA D TE Press Fit D PA TE NTE Information: page 14 Gland bracket Reinforced joint-clamp Information: page 28 PA O TE For conduit size: D PA Information: page 22 N TA D TE NTE M20 PG 13 M20 PG 16 M25 PG 21 Floor foot adhesive Comprises adhesive + hardener Contents: enough for aprox. 100 feet Store and transport temperature range: +5 ºC / +40 ºC Working temperature range: -5 ºC / +60 ºC Earth terminal BRASS Ref. Ref. 68000065 50 /u 1.80 Pack unit 1 68000032 /u 0.024 Pack unit 20 Information: page 24 PEMSA-CAT 219-45-52-REV 27/11/09 11:40 Página 7 Examples of assembly Press Fit Quick, easy installation For proper maintenance, the rack should be at least 40 mm away from the floor. If the rack crosses pipes, the rack must always be above the pipes. Rejiband ensures the highest cleaning and ventilation levels. A B Auxiliary material Cost needed, per meter comparison A M10x20 screw (page 107) Stand off bracket (page 32) Part Clamp (page 24) Exp. plug M10 100 B Floor foot (page 50) Floor foot adhesive (p. 50) 25 51 PEMSA-CAT 219-45-52-REV 27/11/09 11:40 Página 8 rejitech ® Wall and ceiling mounting in reduced spaces and false ceilings PA TE D O PA N TA D TE NTE YES - Quick Installation without joints and bends - The assembly work can be done by just one person - Tidy cabling - Easy to modify NO - Minimum height - Cables can be inserted from the side - Maximum ventilation 52 11:44 Página 1 65 O PA ERTED CABLES INS IDE FROM THE S N TA D TE TE D 27/11/09 PA PEMSA-219-53-90-REV NTE Comparative study rejitech® - PVC CONDUITS Space needed (for the same number of cables) PVC CONDUITS REJITECH Length: 1m for same cable capacity 48 80 48 48 48 48 48 36 36 36 65 1000 100 Fittings needed (per meter) REJITECH - PVC CONDUITS M6 plug M6 screw Ceiling fastener Rejitech 100x60 1 1 1 1 - M6 plugs PG 48 clamp PG 36 clamp PVC pipes 11.25 7.5 3.75 6.3 Assembly time (per meter) - Mark Drill Fit plug Screw Cable 1 1 1 1 1 - Mark Drill Fit plug Screw on cramps Cable 9 11.25* 11.25* 27 9 COST Comparison 20 100 * 0.8 per meter.s/MI.BT.019 53 PEMSA-219-53-90-REV 27/11/09 11:44 Página 2 Rejitech E.G. (Support of cables for installation on ceilings and false ceilings and walls in reduced spaces). A Ref. 100 60215020 BYCRO /m /m mm2 m 0.66 2500 16 Ref. 0.66 60225020 Length 2000 mm Sag for a distance of 1m between supports A 12 60 Sag (mm) PA TE D O PA D T E N TA 10 Maximum sag 8 6 4 NTE 2 0 0 1 2 3 4 50 6 7 8 9 10 11 12 Load (Kg/metre) Ceiling fastener (Press Fit) E.G. E.B. S I S T E M A CLICK Ref. Ø 11x16 /u 67010052 0.028 Ref. 67020052 /u Pack unit 0.028 25 Ø 7x23 Box support for Rejitech E.B. S I S T E M A CLICK Ref. 67020041 Ø 7x50 10 Mount to boxes with M6 screw. E N TA PA TE D O PA 0.023 Pack unit D T /u NTE Rejitech versatile application. Wall and ceiling installation in false ceilings and spaces with reduced accessibility. 65 False ceiling installation 65 Wall installation Material: Steel Working temperature range: -50 ºC / +150 ºC Advantages - Reduced space. Fast installation. No need for brackets. Suitable for light loads. E.G. Electrogalvanised UNE - EN 12329 BYCRO/E.B. Electrolytic Bichromate UNE - EN 12329 Weight in kilos 54 PEMSA-219-53-90-REV 27/11/09 11:44 Página 3 Examples of assembly Assembly without connectors Ceiling fitting Rejitech Assembly in just three steps 1 2 click 3 1m Fit plugs+M6 screws Fit ceiling fasteners every 1 meter aprox. on the Rejitech Fit and screw in assembly 2 Fiting boxes 1 Attach the box to the support 2 Insert assembly 1 in Rejitech 3 Swivel assembly 2 onthe Rejitech 55 PEMSA-219-53-90-REV 27/11/09 11:44 Página 4 pemsabandSystem ® Steel cable tray Metal Sheet Cable Tray manufactured under a fully automated and integrated process with feeders of metal sheet coils. Its exclusive design shows clearly distinguising advantages. 56 PEMSA-219-53-90-REV 27/11/09 11:44 Página 5 ® Pemsa have optimized its range of metal tray by developing three different ranges of pemsaband tray: Metal tray with the base embossed and perforated, it comes packaged to protect the corners and interior parts and also to facilitate hadling and transport. The slotted perforations provide maximum strength for equal weight and thickness. pemsaband SX has at a new joggled coupling system which increases the ease of connection between lenghts and substantially reduces installation time. Thanks to this Click system, you do not need 1 2 3 any coupler just two screws for assembly. NT G D P E TE E PA ® N DIN ck Cli 030/000246 ® The range of pemsaband SX trays are designed and manufactured to the highest standards of quality, based on the product standard IEC 61537. This quality is confirmed by the N mark from AENOR, which guarantees all of its technical characteristics, and the E90 Fire Resistance Certification. Full range on heights 35, 60, 85 and 100. Widths of 100 to 600 mm. NT G D P E TE E PA High load capacity. Thickness = 1.5 mm. Perforated and solid tray manufactured from thicker material to withstand higher loads. Available in 60, 85 and 100 depths. N DIN Perforated and embossed tray with Rapid Click Coupling System in 35 and 60 depths. Over all length is 3.05 metres. ® Furthermore, cables are protected. All this ranges of pemsaband , presents the following features. Embossed perforations Fixing with countersunk screws Maximum strength to weight ratio Safety edge Self fix lid cover Well-finished side/edge P P ® The pemsaband metal channel requires the use of a cover. This channel may be delivered with perforations, depending on the required IP. Perforated metal channel with cover: IP 2x. Solid metal channel with IP 4x cover. TRAY + + COVER = SECURE TRUNKING = PE M SA PE M SA 57 PEMSA-219-53-90-REV 27/11/09 11:44 Página 6 Page 1 - Joiner 2 - Bend joiner 3 - Divider plate 4 - Hinge riser/dropper 5 - Reducer 6 - Cover 7 - Universal bracket 8 - Adjustable bend 9 - 90º gusseted bend 10 - T-intersection 11 - Side entry 12 - Cross-joint 13 - Channel beam clamp 58 68 68 68 70 70 70 72 72 74 74 76 76 106 Page 14 15 16 17 18 - Mesh channel Fitting with one rod Fitting with two rods Cantilever bracket H.D.G. P.G. heavy duty cantilever 90 91 91 84 84 Page 19 20 21 22 - Channel Edge protectors Channel nut Double heavy duty pendant 104 70 104 96 PEMSA-219-53-90-REV 27/11/09 11:44 Página 7 59 PEMSA-219-53-90-REV 27/11/09 11:44 Página 8 The base of the tray is embossed and perforated, certified by the AENOR N mark and E90 DIN-410212. It comes packaged to protect the corners and interior parts and also to facilitate handling and transport. TE NT D G P E E PA P.G. Finish N DIN ø8x20 Length 3050 mm Useful Tray 3000 mm 50 B S m 3000 m Tray = m l fu e s U 0m L=305 A Rapid Click Coupling System with 35 and 60 depths. Click Perforated 35 Click Perforated 60 P.G. P.G. /m S mm2 m AxB Ref. /m S mm2 0.97 2890 24 100x60 75522100 m 1.25 5360 24 1.70 8040 12 1.99 10700 12 2.56 16100 6 75522400 3.13 21700 6 500x60 75522500 4.65 26800 6 600x60 75522600 5.35 32200 6 AxB Ref. 100x35 75521100 150x35 75521150 1.21 4360 12 150x60 75522150 200x35 75521200 1.67 5790 12 200x60 75522200 300x35 75521300 2.24 8710 12 300x60 75522300 400x35 75521400 2.81 11600 6 400x60 500x35 75521500 4.25 14400 6 600x35 75521600 4.96 17300 6 Embossed perforations Fixing with countersunk screws Safety edge System uses couplers with 85 and 100 depths. Well-finished circular flange Perforated 85 Perforated 100 P.G. S mm2 P.G. AxB Ref. 200x85 75223200 2.24 15700 6 300x85 75223300 2.80 23600 6 200x100 75224200 2.43 18600 6 400x85 75223400 4.17 31400 6 300x100 75224300 2.99 28100 6 500x85 75223500 4.90 39300 6 400x100 75224400 4.40 37400 6 600x85 75223600 5.59 47200 6 500x100 75224500 5.14 46800 6 /m m AxB Material: Steel Working temperature range: -50 ºC / +150 ºC Ref. /m S mm2 P.G. Self fix cover m P P Maximum strength to weight ratio Pre-galvanised UNE - EN 10142 H.D.G. Hot-dip galvanised UNE - EN-ISO 1461 Weight in kilos 60 PEMSA-219-53-90-REV 27/11/09 11:44 Página 9 H.D.G. Finish Connects with couplers and comes in 3 metre lengths. Perforated 35 H.D.G. Perforated 60 H.D.G. /m S mm2 m AxB Ref. /m S mm2 1.28 2870 24 100x60 75232100 m 1.64 5330 24 1.96 8040 12 2.28 10700 12 2.94 16100 6 75232400 4.35 21400 6 500x60 75232500 5.18 26800 6 600x60 75232600 5.96 32200 6 AxB Ref. 100x35 75231100 150x35 75231150 1.59 4330 12 150x60 75232150 200x35 75231200 1.92 5790 12 200x60 75232200 300x35 75231300 2.57 8710 12 300x60 75232300 400x35 75231400 3.91 11500 6 400x60 500x35 75231500 4.74 14400 6 600x35 75231600 5.52 17300 6 Embossed perforations Fixing with countersunk screws Safety edge System uses couplers with 85 and 100 depths. Well-finished circular flange Perforated 85 Perforated 100 H.D.G. S mm2 H.D.G. AxB Ref. 200x85 75233200 2.61 15700 6 300x85 75233300 3.94 23500 6 200x100 75234200 2.83 18600 6 400x85 75233400 4.71 31400 6 300x100 75234300 4.21 28000 6 500x85 75233500 5.55 39300 6 400x100 75234400 4.98 37400 6 600x85 75233600 6.33 47200 6 500x100 75234500 5.81 46800 6 /m m AxB Material: Steel Working temperature range: -50 ºC / +150 ºC Ref. /m S mm2 P.G. Self fix cover m P P Maximum strength to weight ratio Pre-galvanised UNE - EN 10142 H.D.G. Hot-dip galvanised UNE - EN-ISO 1461 Weight in kilos 61 Página 10 Width: MAXIMUM SAFE WORKING LOAD (Kg/m) Width: 100 - 150 1 kg = 9.8 N 200 - 300 120 120 110 110 100 100 90 90 80 80 70 70 60 100 - 150 1.5 1.6 1.7 1.8 1.9 50 50 40 40 2.0 1.5 1.6 1.7 1.8 1.9 MAXIMUM SAFE WORKING LOAD (Kg/m) Width: 200 500 - 600 300 - 400 170 170 160 160 150 150 140 140 130 130 120 120 110 110 100 100 90 100 - 150 1 kg = 9.8 N Kg/m 200 90 300 - 400 80 80 70 70 60 60 500 - 600 50 50 40 1.5 1.6 1.7 1.8 1.9 40 2.0 1.5 Distance between supports (metre) 1.7 1.8 1.9 MAXIMUM SAFE WORKING LOAD (Kg/m) Width: 300 200 400 - 500 - 600 140 140 130 130 120 120 110 110 100 100 90 90 80 300 80 400 - 500 - 600 70 70 60 60 50 50 40 1.5 1.6 1.7 1.8 Distance between supports (metre) 2.0 1 kg = 9.8 N Kg/m 200 1.6 Distance between supports (metre) Pemsaband SX 85 Width: 2.0 Distance between supports (metre) Pemsaband SX 60 100 - 150 60 200 - 300 Distance between supports (metre) Width: Kg/m Pemsaband SX 35 Kg/m 11:44 1.9 2.0 Kg/m 27/11/09 Kg/m PEMSA-219-53-90-REV 40 1.5 1.6 1.7 1.8 1.9 2.0 Distance between supports (metre) Values obtained from test according to the UNE-EN 61537 standard, with a safety coefficient of 170% without ever reaching the collapse point. Guaranteed only using our joiner and central joiner for widths from 300 up to 600. Tray section joints be situated at a support distance of between L/4 and L/5, L being the distance between supports. At completed tray extreme ends, tray support distance should be a maximum of 0.4L without any type of joint. 62 PEMSA-219-53-90-REV 27/11/09 11:44 Página 11 solid Solid, smooth base tray certified by the AENOR N mark and E90 DIN-4102-12. It comes packaged to protect the corners and interior parts and also to facilitate handling and transport. NT G D P E TE E PA P.G. Finish N DIN ø8x20 Length 3050 mm Useful Tray 3000 mm 50 m 3000 m Tray = Useful 050 mm L=3 S Solid 35 A Solid 60 P.G. B Rapid Click Coupling System with 35 and 60 depths. P.G. /m S mm2 m AxB Ref. /m S mm2 1.05 2890 24 100x60 75622100 m 1.32 5360 24 1.83 8040 12 2.15 10700 12 2.79 16100 6 75622400 3.43 21700 6 500x60 75622500 5.07 26800 6 600x60 75622600 5.87 32200 6 S mm2 m AxB Ref. 100x35 75621100 150x35 75621150 1.33 4360 12 150x60 75622150 200x35 75621200 1.84 5790 12 200x60 75622200 300x35 75621300 2.48 8710 12 300x60 75622300 400x35 75621400 3.11 11600 6 400x60 500x35 75621500 4.68 14400 6 600x35 75621600 5.48 17300 6 System uses couplers with 85 and 100 depths. Solid 85 Solid 100 P.G. AxB Ref. 200x85 75423200 300x85 400x85 /m S mm2 P.G. m AxB Ref. /m 2.42 15700 6 75423300 3.05 23600 6 200x100 75424200 2.61 18600 6 75423400 4.58 31400 6 300x100 75424300 3.24 28100 6 500x85 75423500 5.37 39300 6 400x100 75424400 4.82 37400 6 600x85 75423600 6.15 47200 6 500x100 75424500 5.60 46800 6 Material: Steel Working temperature range: -50 ºC / +150 ºC P.G. Pre-galvanised UNE - EN 10142 H.D.G. Hot-dip galvanised UNE - EN-ISO 1461 Weight in kilos 63 PEMSA-219-53-90-REV 27/11/09 11:44 Página 12 solid H.D.G. Finish M E P A S PEMSA Connects with couplers and comes in 3 metre lengths. Rapid Click Coupling System with 35 and 60 depths. Solid 35 Solid 60 H.D.G. H.D.G. /m S mm2 m AxB Ref. /m S mm2 1.36 2870 24 100x60 75432100 m 1.73 5330 24 2.09 8040 12 2.45 10700 12 3.19 16100 6 75432400 4.74 21400 6 500x60 75432500 5.63 26800 6 600x60 75432600 6.51 32200 6 AxB Ref. 100x35 75431100 150x35 75431150 1.73 4330 12 150x60 75432150 200x35 75431200 2.09 5790 12 200x60 75432200 300x35 75431300 2.81 8710 12 300x60 75432300 400x35 75431400 4.30 11500 6 400x60 500x35 75431500 5.18 14400 6 600x35 75431600 6.07 17300 6 System uses couplers with 85 and 100 depths. Safety edge Solid 85 Solid 100 H.D.G. AxB Ref. /m S mm2 H.D.G. m AxB Ref. /m S mm2 m 200x85 75433200 2.81 15700 6 300x85 75433300 4.29 23500 6 200x100 75434200 3.03 18600 6 400x85 75433400 5.17 31400 6 300x100 75434300 4.55 28000 6 500x85 75433500 6.06 39300 6 400x100 75434400 5.44 37400 6 600x85 75433600 6.95 47200 6 500x100 75434500 6.33 46800 6 Material: Steel Working temperature range: -50 ºC / +150 ºC P.G. Well-finished circular flange Self-fix cover Pre-galvanised UNE - EN 10142 H.D.G. Hot-dip galvanised UNE - EN-ISO 1461 Weight in kilos 64 PEMSA-219-53-90-REV 27/11/09 11:44 Página 13 High load capacity. Thickness = 1.5 mm. Perforated and solid tray manufactured from thicker material to withstand higher loads. The entire range can be supplied on request. Available in 60, 85 and 100 depths. NEW CHECK AVAILABILITY ø8x20 P.G. Finish Perforated 60 Perforated 85 P.G. Thickness mm 1,5 AxB Ref. 100x60 76122100 /m S mm2 m 2.22 5260 24 Perforated 100 P.G. AxB Ref. /m S mm2 P.G. m S mm2 m 4.49 18400 6 5.52 27700 6 400x100 76124400 6.56 37100 6 500x100 76124500 7.64 46400 6 S mm2 m AxB Ref. 200x60 76122200 3.54 10500 12 200x85 76123200 4.06 15400 6 300x60 76122300 4.65 15800 6 300x85 76123300 5.17 23300 6 200x100 76124200 400x60 76122400 5.69 21200 6 400x85 76123400 6.21 31100 6 300x100 76124300 500x60 76122500 6.79 26500 6 500x85 76123500 7.32 39000 6 600x60 76122600 7.89 31900 6 600x85 76123600 8.42 46800 6 /m H.D.G. Finish Perforated 60 Perforated 85 H.D.G. Thickness mm 1,5 AxB Ref. 100x60 76132100 /m S mm2 m 2.78 5230 24 Perforated 100 H.D.G. AxB Ref. /m S mm2 H.D.G. m AxB Ref. /m 200x60 76132200 3.86 10500 12 200x85 76133200 4.42 15400 6 300x60 76132300 5.06 15800 6 300x85 76133300 5.62 23300 6 200x100 76134200 4.88 18400 6 400x60 76132400 6.19 21200 6 400x85 76133400 6.76 31100 6 300x100 76134300 6.01 27700 6 500x60 76132500 7.40 26500 6 500x85 76133500 7.97 39000 6 400x100 76134400 7.14 37100 6 600x60 76132600 8.59 31900 6 600x85 76133600 9.16 46800 6 500x100 76134500 8.33 46400 6 Material: Steel Working temperature range: -50 ºC / +150 ºC P.G. Pre-galvanised UNE - EN 10142 H.D.G. Hot-dip galvanised UNE - EN-ISO 1461 Weight in kilos 65 PEMSA-219-53-90-REV 27/11/09 11:44 Página 14 solid NEW M E P A S CHECK AVAILABILITY PEMSA Perforated 85 P.G. Finish Perforated 100 P.G. Thickness mm 1,5 AxB Ref. /m S mm2 P.G. m S mm2 m 4.85 18400 6 6.03 27700 6 400x100 76324400 7.21 37100 6 500x100 76324500 8.39 46400 6 S mm2 m AxB Ref. 200x85 76323200 4.50 15400 6 300x85 76323300 5.68 23300 6 200x100 76324200 400x85 76323400 6.86 31100 6 300x100 76324300 500x85 76323500 8.03 39000 6 600x85 76323600 9.21 46800 6 /m Perforated 85 H.D.G. Finish Perforated 100 H.D.G. Thickness mm 1,5 Material: Steel Working temperature range: -50 ºC / +150 ºC AxB Ref. /m S mm2 H.D.G. m AxB Ref. /m 200x85 76333200 4.89 15400 6 300x85 76333300 6.17 23300 6 200x100 76334200 5.37 18400 6 400x85 76333400 7.45 31100 6 300x100 76334300 6.55 27700 6 500x85 76333500 8.73 39000 6 400x100 76334400 7.83 37100 6 600x85 76333600 10.00 46800 6 500x100 76334500 9.11 46400 6 P.G. Pre-galvanised UNE - EN 10142 H.D.G. Hot-dip galvanised UNE - EN-ISO 1461 Weight in kilos 66 PEMSA-219-53-90-REV 27/11/09 11:44 Página 15 NT G D P E TE E PA Perforated and embossed tray with Rapid Click Coupling System in 35 and 60 depths. Overall length is 3.05 metres. N DIN NEW ø8x20 50 B S m 3000 m Tray = Useful mm L=3050 A P.G. Finish Perforated Click 35 Perforated Click 60 P.G. P.G. /m S mm2 m AxB Ref. /m S mm2 0.70 2950 840 100x60 75822100 m 0.90 5420 720 1.29 8120 492 1.50 10800 360 2.23 16300 204 75822400 2.74 21600 180 500x60 75822500 3.73 27200 156 600x60 75822600 4.30 32400 72 AxB Ref. 100x35 75821100 150x35 75821150 0.87 4440 504 150x60 75822150 200x35 75821200 1.26 5860 420 200x60 75822200 300x35 75821300 1.69 8810 252 300x60 75822300 400x35 75821400 2.46 11700 288 400x60 500x35 75821500 3.42 14500 240 600x35 75821600 3.98 17400 138 Material: Steel Working temperature range: -50 ºC / +150 ºC P.G. Pre-galvanised UNE - EN 10142 H.D.G. Hot-dip galvanised UNE - EN-ISO 1461 Weight in kilos 67 PEMSA-219-53-90-REV 27/11/09 11:45 Página 16 Joiner P.G. A 7 H.D.G. 35 71021005 0.039 71031005 0.042 Pack unit 50 60 71022005 0.101 71032005 0.117 50 85 71023005 0.152 71033005 0.169 25 Ref. /u Ref. /u Central Joiner P.G. A Ref. ø7x45 Use only with 300-600 trays H.D.G. /u Ref. /u Pack unit 300 71020300 0.37 71030300 0.39 10 400 71020400 0.49 71030400 0.52 10 500 71020500 0.61 71030500 0.64 10 600 71020600 0.74 71030600 0.77 10 Divider plate PA TE D O PA S I S T E M A CLICK N TA D TE NTE P.G. A Ref. A H.D.G. /m m 25 67020610 0.26 /m 67030610 Ref. 0.30 60 50 67020611 0.38 67030611 0.43 48 80 67020612 0.53 67030612 0.60 36 The PG finish come packaged for correct storage. HD and stainless steel finishing is supplied in plastic tensed strip packaging for easy storage. Length 3 m Identification label PLASTIC LABEL Ref. O PA N TA D TE 68000020 D PA TE NTE /u 0.002 Pack unit 50 Working temperature range:: -20 ºC / +60 ºC Stand off bracket A 40 07 x 50 07 x 30 P.G. A 40 N A Ref. 012 x 25 07 x 30 1000 H.D.G. /u Ref. P.G. 67030539 0.17 67030541 0.24 10 350 67030540 0.32 67030542 0.35 10 Pre-galvanised UNE - EN 10142 H.D.G. Hot-dip galvanised UNE - EN-ISO 1461 Weight in kilos 68 Pack unit 180 012 x 25 Material: Steel Working temperature range: -50 ºC / +150 ºC /u PEMSA-219-53-90-REV 27/11/09 11:45 Página 17 Examples of assembly 2 4 PE 1 PE MS MS A A PE MS PE A PE MS A AS ME MS A P 1 1 2 1 2 3 2 1 PE MS 4 PE MS A A 1 DIN 603 M6x12 screw (page 107) 2 M6 serrated hexagon flange nut (p. 107) 3 Joiner coupler (page 68) 4 Central joiner (page 68) 69 PEMSA-219-53-90-REV 27/11/09 11:45 Página 18 Riser/Dropper 7 P.G. A Ref. 35 150 18 71021006 0.027 Ref. Bolts not included 60 44 Ref. 71031006 P.G. A A H.D.G. /u 0.03 Pack unit 4 H.D.G. /u 71022006 /u 0.072 Ref. 71032006 /u 0.078 Pack unit 4 Four units required for each riser/dropper Protector (for ends & edges) ARMOUR PVC Ref. 71000000 /m m 0.15 10 Working temperature range:: -5 ºC / +60 ºC Delivered in meters Reducer ø7x20 P.G. A A 0 10 H.D.G. 35 71021007 0.037 71031007 0.041 Pack unit 4 60 71022007 0.074 71032007 0.081 4 A Ref. /m m 060 73021060 0.47 73031060 0.62 24 100 73021100 0.74 73031100 0.84 24 150 73021150 1.02 73031150 1.14 12 200 73021200 1.30 73031200 1.60 12 300 73021300 2.11 73031300 2.30 6 400 73021400 2.74 73031400 3.68 6 500 73021500 4.22 73031500 4.54 6 600 73021600 5.01 73031600 5.40 6 Ref. Cover /m Ref. P.G. A S I S T E M A CLICK Length 3 m Self-fix installation (no bolts or nuts needed) Material: Steel Working temperature range: -50 ºC / +150 ºC P.G. H.D.G. /m Ref. Pre-galvanised UNE - EN 10142 H.D.G. Hot-dip galvanised UNE - EN-ISO 1461 Weight in kilos 70 /m PEMSA-219-53-90-REV 27/11/09 11:45 Página 19 Examples of assembly PE MS A 1 2 3 PE MS A 3 AS ME P 1 AS ME P TRAY + COVER = SAFETY TRUNKING IP 2X (Pemsaband Perforated) 4X (Pemsaband Solid) PE MS A 1 DIN 603 M6x12 screw (page 107) 2 Edge protector (page 70) 3 M6 serrated hexagon flange nut (page 107) 71 PEMSA-219-53-90-REV 27/11/09 11:45 Página 20 Universal bracket (Pemsaband) Connector plate Ø7 109 ø7x20 0 17 E.G. P.G. Ref. H.D.G. Ref. /u 70420911 0.18 0.19 H.D.G. Ref. /u 64010062 Pack unit /u 70430911 E.B. Ref. 0.01 Ref. /u 64020062 0.009 /u 64030062 0.01 Pack unit 50 10 For fixing BOXES, use M-5 bolts Adjustable bend Click NEW S I S T E M A CLICK PA TE D O PA N TA D TE NTE P.G. AxB Ref. H.D.G. /u Ref. P.G. /u Pack unit AxB H.D.G. Ref. /u Ref. /u Pack unit 35 100x35 70028110 0.22 70038110 0.24 1 60 100x60 70028210 0.30 70038210 0.32 1 150x35 70028115 0.36 70038115 0.39 1 150x60 70028215 0.45 70038215 0.48 1 200x35 70028120 0.49 70038120 0.52 1 200x60 70028220 0.57 70038220 0.61 1 300x35 70028130 0.85 70038130 0.91 1 300x60 70028230 0.96 70038230 1.03 1 Colour Width m/roll /u Rejifix ● Self-adhesive for data cables and telecommunications. ● Does not damage the cables. Re-usable. Ref. nº 89011000 NEGRO 10 mm 25 m Contents: 400 ml. Ref. 68000052 /u 0.52 Pack unit 1 Store and transport temperature range: -20 ºC / +40 ºC Working temperature range: -50 ºC / +150 ºC Weight in kilos 72 1 Working temperature range: -5 ºC / +90 ºC Zinc paint spray Material: Steel Working temperature range: -50 ºC / +150 ºC 0.14 Pack unit E.G. E.B. P.G. H.D.G. Spray OR ZINC Electrogalvanised UNE - EN 12329 Electrolytic Bichromate UNE - EN 12329 Pre-galvanised UNE - EN 10142 Hot-dip galvanised UNE - EN-ISO 1461 PEMSA-219-53-90-REV 27/11/09 11:45 Página 21 Examples of assembly 1 4 PE MS A PE MS A PE M SA 2 3 Connector plate 3 2 Suitable for 16-35 mm2 Al/Cu cables 90º Adjustable 180º 4 1 PE MS A AS P ME 1 DIN 603 M6x12 screw (page 107) 2 DIN 603 M6x20 screw + nut M6 (page 107) 3 Connector plate (page 72) 4 M6 serrated haxagon flange nut (page 107) 73 PEMSA-219-53-90-REV 27/11/09 11:45 Página 22 TE Ref. NT D G P E P.G. AxB E PA 90º Bend Click N DIN B A The finished P.G. is given in plane for later assembly. The finished H.D.G. is given shaped. 0.36 70030110 0.41 1 70020115 0.56 70030115 0.63 1 200x35 70020120 0.78 70030120 0.88 1 300x35 70020130 1.32 70030130 1.48 1 100x60 70020210 0.48 70030210 0.54 1 150x60 70020215 0.69 70030215 0.78 1 200x60 70020220 0.93 70030220 1.04 1 300x60 70020230 1.49 70030230 1.68 1 400x60 70020240 2.19 70030240 2.46 1 500x60 70020250 3.00 70030250 3.38 1 600x60 70020260 3.95 70030260 4.44 1 200x85 70020320 1.06 70030320 1.20 1 300x85 70020330 1.66 70030330 1.87 1 400x85 70020340 2.39 70030340 2.69 1 500x85 70020350 3.24 70030350 3.65 1 600x85 70020360 4.21 70030360 4.74 1 P.G. A D PA E G P 0.27 73030100 0.30 1 73020150 0.43 73030150 0.48 1 200 73020200 0.62 73030200 0.70 1 300 73020300 1.10 73030300 1.24 1 400 73020400 1.70 73030400 1.92 1 500 73020500 2.44 73030500 2.74 1 600 73020600 3.29 73030600 3.70 1 NT D G P N DIN The finished P.G. is given in plane for later assembly. The finished H.D.G. is given shaped. Ref. /u Pack unit 70022110 0.47 70032110 0.52 1 70022115 0.69 70032115 0.78 1 200x35 70022120 0.94 70032120 1.06 1 300x35 70022130 1.15 70032130 1.73 1 100x60 70022210 0.60 70032210 0.68 1 150x60 70022215 0.83 70032215 0.93 1 200x60 70022220 1.09 70032220 1.22 1 300x60 70022230 1.70 70032230 1.91 1 400x60 70022240 2.43 70032240 2.74 1 500x60 70022250 3.29 70032250 3.71 1 600x60 70022260 4.28 70032260 4.82 1 200x85 70022320 1.23 70032320 1.38 1 300x85 70022330 1.85 70032330 2.09 1 400x85 70022340 2.60 70032340 2.93 1 500x85 70022350 3.48 70032350 3.92 1 600x85 70022360 4.48 70032360 5.05 1 P.G. A Ref. E G D P N DIN A Weight in kilos H.D.G. /u 150x35 NT 74 P.G. 100x35 Tee Click Cover Material: Steel Working temperature range: -50 ºC / +150 ºC Pack unit 73020100 Ref. A PA /u 150 AxB B E Ref. 100 E PA Tee Click TE H.D.G. /u NT A E Pack unit 70020110 N DIN TE /u 150x35 Ref. E Ref. 100x35 90º Bend Click Cover TE H.D.G. /u E.G. E.B. P.G. H.D.G. H.D.G. /u Ref. /u Pack unit 100 73022100 0.36 73032100 0.40 1 150 73022150 0.55 73032150 0.62 1 200 73022200 0.77 73032200 0.87 1 300 73022300 1.31 73032300 1.48 1 400 73022400 1.98 73032400 2.23 1 500 73022500 2.77 73032500 3.12 1 600 73022600 3.69 73032600 4.15 1 Electrogalvanised UNE - EN 12329 Electrolytic Bichromate UNE - EN 12329 Pre-galvanised UNE - EN 10142 Hot-dip galvanised UNE - EN-ISO 1461 PEMSA-219-53-90-REV 27/11/09 11:45 Página 23 TE NT G D P E E PA Examples of assembly N DIN Click System. It is not necessary to use joints toattach to the accessories straight sections of pemsaband. 6 2 1 5 DN20 precut conduit exits. In heights 60 and 85 for installation fittings or glands of M20, PG11 or PG13. 5 90º Bend Click 60x300 (page 74) 6 90º Bend Click Cover 60x300 (page 74) Covers accessories are overlap on the tray, improving the tightness and stiffness of the assembly. 4 3 1 2 1 Shoulder screw c/DIN 603 M6x12 3 Tee Click 35x300 (page 74) 2 Serrated hexagon flange nut M6 4 Tee Click Cover 300 (page 74) (page 107) In the schemes of the page does not show the covers straight to help better display accessories. 75 PEMSA-219-53-90-REV 27/11/09 11:45 Página 24 Side Entry Click P.G. AxB TE D G P E N DIN A B Lets build a Tee at any place and trays can be of different width (eg. 300-100) The finished P.G. is given in plane for later assembly. The finished H.D.G. is given shaped. 0.29 70033110 0.32 1 70023115 0.35 70033115 0.39 1 200x35 70023120 0.41 70033120 0.46 1 300x35 70023130 0.53 70033130 0.59 1 100x60 70023210 0.35 70033210 0.40 1 150x60 70023215 0.41 70033215 0.47 1 200x60 70023220 0.47 70033220 0.53 1 300x60 70023230 0.59 70033230 0.67 1 400x60 70023240 0.71 70033240 0.80 1 500x60 70023250 0.83 70033250 0.94 1 600x60 70023260 0.95 70033260 1.07 1 200x85 70023320 0.54 70033320 0.61 1 300x85 70023330 0.66 70033330 0.75 1 400x85 70023340 0.78 70033340 0.88 1 600x85 70023350 0.90 70033350 1.02 1 600x85 70023360 1.02 70033360 1.15 1 Ref. D /u Pack unit 100 73023100 0.19 73033100 0.22 1 150 73023150 0.24 73033150 0.27 1 200 73023200 0.29 73033200 0.32 1 300 73023300 0.38 73033300 0.43 1 400 73023400 0.47 73033400 0.53 1 500 73023500 0.57 73033500 0.64 1 600 73023600 0.66 73033600 0.75 1 P.G. AxB NT TE E D PA Ref. G N DIN Ref. G P N DIN A The finished P.G. is given in plane for later assembly. The finished H.D.G. is given shaped. Pack unit 0.58 70034110 0.65 1 70024115 0.84 70034115 0.94 1 200x35 70024120 1.12 70034120 1.26 1 300x35 70024130 1.78 70034130 2.00 1 100x60 70024210 0.73 70034210 0.82 1 150x60 70024215 0.98 70034215 1.10 1 200x60 70024220 1.26 70034220 1.42 1 300x60 70024230 1.92 70034230 2.16 1 400x60 70024240 2.70 70034240 3.04 1 500x60 70024250 3.61 70034250 4.06 1 600x60 70024260 4.64 70034260 5.23 1 200x85 70024320 1.40 70034320 1.58 1 300x85 70024330 2.06 70034330 2.32 1 400x85 70024340 2.84 70034340 3.20 1 500x85 70024350 3.75 70034350 4.22 1 600x85 70024360 4.78 70034360 5.38 1 P.G. A E NT TE G D P N DIN A 76 /u 70024110 Ref. Weight in kilos Ref. 150x35 Crossover Click cover Material: Steel Working temperature range: -50 ºC / +150 ºC H.D.G. /u 100x35 B PA H.D.G. /u E PA P.G. A Crossover Click E Pack unit 70023110 A E /u 150x35 ENT P E Ref. 100x35 Side entry Click cover T H.D.G. /u NT E PA Ref. E.G. E.B. P.G. H.D.G. H.D.G. /u Ref. /u Pack unit 100 73024100 0.46 73034100 0.52 1 150 73024150 0.80 73034150 0.77 1 200 73024200 1.11 73034200 1.05 1 300 73024300 1.82 73034300 1.73 1 400 73024400 2.66 73034400 2.55 1 500 73024500 3.63 73034500 3.51 1 600 73024600 4.72 73034600 4.61 1 Electrogalvanised UNE - EN 12329 Electrolytic Bichromate UNE - EN 12329 Pre-galvanised UNE - EN 10142 Hot-dip galvanised UNE - EN-ISO 1461 PEMSA-219-53-90-REV 27/11/09 11:45 Página 25 G E NT D P Click System. It is not necessary to use joints toattach to the accessories straight sections of pemsaband. TE E PA Examples of assembly N DIN 4 3 1 2 3 Covers accessories are overlap on the tray, improving the tightness and stiffness of the assembly. Side entry Click 60x300 (page 76) 4 Side entry Click cover 300 (page 76) 6 5 DN20 precut conduit exits. In heights 60 and 85 for installation fittings or glands of M20, PG11 or PG13. 1 Shoulder screw c/DIN 603 M6x12 2 Serrated hexagon flange nut M6 5 Crossover Click 85x300 (page 76) 6 Crossover Click cover (page 76) (page 107) In the schemes of the page does not show the covers straight to help better display accessories. 77 PEMSA-219-53-90-REV 27/11/09 11:45 Página 26 Inside Riser Click P.G. AxB TE D G P E N DIN B A The finished P.G. is given in plane for later assembly. The finished H.D.G. is given shaped. 0.33 70035110 0.38 1 70025115 0.43 70035115 0.48 1 200x35 70025120 0.53 70035120 0.60 1 300x35 70025130 0.75 70035130 0.84 1 100x60 70025210 0.42 70035210 0.48 1 150x60 70025215 0.54 70035215 0.61 1 200x60 70025220 0.65 70035220 0.74 1 300x60 70025230 0.89 70035230 1.00 1 400x60 70025240 1.12 70035240 1.26 1 500x60 70025250 1.35 70035250 1.52 1 600x60 70025260 1.58 70035260 1.78 1 200x85 70025320 0.73 70035320 0.82 1 300x85 70025330 0.96 70035330 1.08 1 400x85 70025340 1.19 70035340 1.34 1 500x85 70025350 1.43 70035350 1.61 1 600x85 70025360 1.66 70035360 1.87 1 /u /u Pack unit D G 73025100 0.13 73035100 0.15 1 150 73025150 0.19 73035150 0.21 1 200 73025200 0.25 73035200 0.28 1 300 73025300 0.36 73035300 0.40 1 400 73025400 0.47 73035400 0.53 1 500 73025500 0.59 73035500 0.66 1 600 73025600 0.70 73035600 0.79 1 P.G. Ref. NT D G B /u Ref. /u Pack unit 100x35 70026110 0.31 70036110 0.35 1 150x35 70026115 0.35 70036115 0.39 1 200x35 70026120 0.43 70036120 0.49 1 300x35 70026130 0.61 70036130 0.68 1 100x60 70026210 0.38 70036210 0.43 1 150x60 70026215 0.47 70036215 0.52 1 200x60 70026220 0.55 70036220 0.62 1 300x60 70026230 0.72 70036230 0.81 1 400x60 70026240 0.90 70036240 1.01 1 500x60 70026250 1.07 70036250 1.20 1 600x60 70026260 1.24 70036260 1.40 1 200x85 70026320 0.68 70036320 0.76 1 300x85 70026330 0.85 70036330 0.96 1 400x85 70026340 1.02 70036340 1.15 1 500x85 70026350 1.19 70036350 1.34 1 600x85 70026360 1.37 70036360 1.54 1 Outside Riser Cover Click P.G. A Ref. E NT TE G D P N DIN A Material: Steel Working temperature range: -50 ºC / +150 ºC Weight in kilos 78 H.D.G. E P N DIN The finished P.G. is given in plane for later assembly. The finished H.D.G. is given shaped. PA Ref. 100 AxB A E H.D.G. E PA Ref. Outside Riser Click PA P.G. A A E Pack unit 70025110 N DIN TE /u 150x35 NT P E Ref. 100x35 Inside Riser Cover Click TE H.D.G. /u NT E PA Ref. E.G. E.B. P.G. H.D.G. H.D.G. /u Ref. /u Pack unit 100 73026100 0.28 73036100 0.32 1 150 73026150 0.40 73036150 0.45 1 200 73026200 0.52 73036200 0.59 1 300 73026300 0.76 73036300 0.85 1 400 73026400 0.99 73036400 1.12 1 500 73026500 1.23 73036500 1.39 1 600 73026600 1.47 73036600 1.65 1 Electrogalvanised UNE - EN 12329 Electrolytic Bichromate UNE - EN 12329 Pre-galvanised UNE - EN 10142 Hot-dip galvanised UNE - EN-ISO 1461 PEMSA-219-53-90-REV 27/11/09 11:45 Página 27 Examples of assembly NEW PIECES Inside Riser Outside Riser Heights 35, 60, 85 G PA NT D P E TE E Click System. It is not necessary to use joints toattach to the accessories straight sections of pemsaband. N DIN 4 2 3 3 Outside Riser Click 60x200 (page 78) 1 4 Outside Riser Cover Click 200 (page 78) 5 Inside Riser Click 60x200 Covers accessories are overlap on the tray, improving the tightness and stiffness of the assembly. (page 78) 6 Inside Riser Cover Click 200 (page 78) 6 5 DN20 precut conduit exits. In heights 60 and 85 for installation fittings or glands of M20, PG11 or PG13. 1 Shoulder screw c/DIN 603 M6x12 (page 107) 2 Serrated hexagon flange nut M6 (page 107) 79 PEMSA-219-53-90-REV 27/11/09 11:45 Página 28 Wall assembly Horizontal Rejiband Security Pemsa Rejiband Security Pemsa Rejiband Security Pemsa Medium Duty Cantilever Rejiband Security Pemsa Medium Duty Cantilever on channel Omega support Omega support on channel 580/1180 N 580/1180 N 1200/2530 N 1200/2530 N 100 page 82 page 82 page 84 page 84 150 page 82 page 82 page 84 page 84 200 page 82 page 82 page 84 page 84 300 page 82 page 82 page 84 page 84 400 page 84 page 84 500 page 84 page 84 600 page 84 page 84 Admissible load ❶ TRAY WIDTH: ❶ Values obtained from test according to the UNE-EN 61537 standard, with a safety coefficient of 170% without ever reaching the collapse point. Guaranteed only for our hanger with security plug and supports reinforced with the PEMSA structural reinforcement. 80 PEMSA-219-53-90-REV 27/11/09 11:45 Página 29 Horizontal Heavy Duty Cantilever Heavy Duty Cantilever on channel 1840/2490 N 1840/2490 N Inclined Vertical Adjustable Medium Duty Cantilever Stand off bracket 1210/2060 N 1000 N R E I N F O R C E D S U P P O R T S G R E AT E R L O A D - B E A R I N G C A PA C I T Y page 84 page 32 page 84 page 32 page 84 page 32 page 84 page 84 page 84 page 32 page 84 page 84 page 84 page 32 page 84 page 84 page 84 page 32 page 84 page 84 page 84 page 32 NOTE!! E FIT SUITABL E WALL! PLUGS IN TH 81 PEMSA-219-53-90-REV 27/11/09 11:45 Página 30 Omega bracket O PA N TA D TE ø11x30 D PA TE NTE B 11 50 7x20 A ● Including Omega plug (preassembled) and Omega protector. ● Guarantees and improves the performance of the OMEGA SUPPORTS. ● Makes fitting easier and aids proper fitting of the support. N P.G. AxB Ref. H.D.G. /u Ref. Pack unit /u 1180 100x145 62021103 0.26 62031103 0.28 5 1040 150x145 62021153 0.30 62031153 0.32 5 1150 200x145 62021203 0.47 62031203 0.50 5 870 300x145 62021303 0.60 62031303 0.63 5 580 400x145 62021403 0.73 62031403 0.78 5 Working temperature range: -5 ºC / +90 ºC Examples of assembly 1 Hexagonal set screw M10x35 (page 107) 2 Washer M10 (page 107) 3 Safety plug 3 2 1 Material: Steel Working temperature range: -50 ºC / +150 ºC Weight in kilos N= Load capacity per support in Newtons as per Standard UNE-EN 61537 82 P.G. Pre-galvanised UNE - EN 10142 H.D.G. Hot-dip galvanised UNE - EN-ISO 1461 PEMSA-219-53-90-REV 27/11/09 11:45 Página 31 Others Omega System Products Omega ceiling bracket N P.G. A Ref. /u Pack unit 760 100 62022103 0.42 62032103 0.44 4 D PA 960 150 62022153 0.62 62032153 0.66 4 800 200 62022203 0.67 62032203 0.72 4 650 300 62022303 0.82 62032303 0.86 4 340 400 62022403 0.94 62032403 0.99 4 NTE 200 TE O PA Ref. N TA D TE H.D.G. /u ø7x20 50 11 ● Including Omega plug (preassembled) and Omega protector. ● Guarantees and improves the performance of the OMEGA SUPPORTS. ● Makes fitting easier and aids proper fitting of the support. A Omega pendant bracket P.G. A 50 Ref. H.D.G. /u Ref. /u Pack unit 300 62021303 0.42 62031303 0.45 5 400 62021403 0.63 62031403 0.67 5 500 62021503 0.70 62031503 0.74 5 600 62021603 0.84 62031603 0.88 5 A Including Omega plug (preassembled) and new Omega protector. ø7x20 11 For further information about these products and the asembly to ceiling, please consult pages 92 to 95. 83 PEMSA-219-53-90-REV 27/11/09 11:45 Página 32 Medium Duty Cantilever P.G. 30 35 P.G. AxB NEW! A B 7X20 PA TE /u Pack unit 100x54 62025103 0.18 2530 4 150x54 62025153 0.23 1890 4 200x54 62025203 0.38 1560 4 300x54 62025303 0.53 1240 4 400x92 62025403 0.76 1220 4 500x92 62025503 0.93 1210 4 600x92 62025603 1.09 1200 4 D O PA E N TA D T N Ref. NTE Medium Duty Cantilever 40 H.D.G. 12X16 30 AxB NEW! 30 H.D.G. N Ref. A B /u S.S. 316 Ref. N /u Pack unit 100x50 62035103 0.23 2060 62065103 0.19 1930 4 150x50 62035153 0.28 1870 62065153 0.24 1720 4 200x50 62035203 0.33 1780 62065203 0.28 1610 4 300x50 62035303 0.42 1690 62065303 0.37 1500 4 400x77 62035403 0.77 1840 62065403 0.70 1580 4 500x77 62035503 1.92 1640 62065503 0.84 1380 4 600x77 62035603 1.06 1210 62065603 0.98 1180 4 35 PA TE D O PA 7X20 N TA D TE NTE Heavy Duty Cantilever 12X16 40 AxB 30 H.D.G. N Ref. /u 30 NEW! A 117 B Pack unit 300x77 63033303 0.79 2490 4 400x77 63033403 0.99 2160 4 500x77 63033503 1.19 2000 4 600x77 63033603 1.38 1840 4 7X20 35 O PA N TA D TE D PA TE NTE Adjustable Medium Duty Cantilever Ø12 46 AxB 47 104 A NEW! B PA TE 7X20 35 Pack unit 100x74 62037103 0.54 2060 4 150x74 62037153 0.59 1870 4 200x74 62037203 0.63 1780 4 300x74 62037303 0.73 1690 4 400x74 62037403 1.08 1840 4 500x74 62037503 1.23 1640 4 600x74 62037603 1.37 1210 4 Delivered unassembled. All pieces included. NTE Material: Steel Working temperature range: -50 ºC / +150 ºC Weight in kilos N= Load capacity per support in Newtons as per Standard UNE-EN 61537 84 N /u D O PA N TA D TE H.D.G. Ref. P.G. H.D.G. S.S. Pre-galvanised UNE - EN 10142 Hot-dip galvanised UNE - EN-ISO 1461 Passivated stainless steel AISI 316 PEMSA-219-53-90-REV 27/11/09 11:45 Página 33 Exemples of assembly SUPPORTS 6 5 4 Wall mounting 3 1 5 2 1 Medium duty cantilever P.G. 2 Medium duty cantilever Channel mounting 4 H.D.G. 3 Heavy duty channel 41x21 H.D.G. (page 104) 4 Hexagonal screw M10 (page 107) 5 Washer M10 (page 107) 6 Channel nut M10 (page 104) PA TE D O PA DISTINCT CHARACTERISTICS N TA D TE Reinforced Strength NTE The bracket has been designed with curves for greater strength and load bearing capacity. Click System Fixing pin for quickly securing the tray thus avoiding movement in any direction. Lateral Grooves Increases the load resistance of the bracket and reinforces the area supporting the tray. PA TE D O PA N TA D TE NTE Side Pressing Fully embossed side enhances the strength of the bracket and improves it’s load capacity. Back Pressing Embossed back increases the resistance of the bracket and prevents any bending. 85 PEMSA-219-53-90-REV 27/11/09 11:45 Página 34 Ceiling assembly With threaded rods Admissible load ❶ 690 N 690 N 1275 N 100 page 88-91 page 88-91 page 88-91 150 page 88-91 page 88-91 page 88-91 TRAY WIDTH: 200 page 88-91 300 400 500 600 + EASY CABLE LAYING ❶Values obtained from test according to the UNE-EN 61537 standard, with a safety coefficient of 170% without ever reaching the collapse point. Guaranteed only for our hanger with security plug. 86 PEMSA-219-53-90-REV 27/11/09 11:45 Página 35 With threaded rods 1760/2760 N 800 N 1760/2000 N 1760/3320 N page 88-91 page 88-91 page 88-91 page 88-91 page 88-91 page 88-91 page 88-91 page 88-91 page 88-91 page 88-91 page 88-91 page 88-91 4310/4890 N page 88-91 page 88-91 page 88-91 + ASSEMBLY TIME SAVING NOTE!! E PLUGS FIT SUITABL ING! IN THE CEIL 87 PEMSA-219-53-90-REV 27/11/09 11:45 Página 36 Horizontal angle hanger Vertical angle hanger A PASSIVATED PASSIVATED N A A Ref. /u N Pack unit A Ref. Pack unit 690 1.5-5 68000721 0.05 100 690 1.5-5 68000731 0.04 100 690 4-10 68000722 0.05 100 690 4-10 68000732 0.04 100 Ceiling bracket Variable ceiling rod bracket H.D.G. P.G. N Ref. 2760 50 /u 67030060 /u 0.094 N Pack unit 10 Ref. 1275 67030061 /u 0.15 Pack unit 1 Use with M8/M10 rods 40 Rod connector M8 E.B. Ref. 30 67020067 /u 0.016 Pack unit 50 Threaded M6/M8/M10 N E.G. AxB 67010140 0.12 67020140 0.12 Pack unit 50 67010141 0.24 67020141 0.24 50 4000 M8x500 M8 4000 M8x1000 - - 67020044 0.16 50 - - 67020045 0.32 50 M10 5000 M10x1000 - - 67020145 0.49 50 Ref. M6 Material: Steel Working temperature range: -50 ºC / +150 ºC Weight in kilos N= Load capacity per support in Newtons as per Standard UNE-EN 61537 88 E.B. 1980 M6x500 1980 M6x1000 E.G. E.B. P.G. H.D.G. /u Ref. Electrogalvanised UNE - EN 12329 Electrolytic Bichromate UNE - EN 12329 Pre-galvanised UNE - EN 10142 Hot-dip galvanised UNE - EN-ISO 1461 /u PEMSA-219-53-90-REV 27/11/09 11:45 Página 37 Examples of assembly 1 1 5 3 2 4 1 4 1 6 7 1 5 2 6 Threaded rod M8 (page 88) Fitting to ceiling (page 88) 3 M10x40 screw (page 107) 4 Threaded rod M10 (page 88) 7 Fitting to sloping ceiling (page 88) Beam clamp hanging assembly (p. 90) Threaded rod M-10 (page 88) 89 PEMSA-219-53-90-REV 27/11/09 11:45 Página 38 Mesh channel N 4890 200 63022203 0.23 63032203 0.24 10 2540 4740 300 63022303 0.33 63032303 0.34 10 1760 4600 400 63022403 0.42 63032403 0.45 10 - 4460 500 63022503 0.52 63032503 0.55 10 - 4310 600 63022603 0.62 63032603 0.65 10 7x20 /u Ref. /u Working Temperature range with safety plug: -5 ºC / +105 ºC E N TA D PA TE D O PA Ref. NTE Safety plug included for better performance on widths 200-400 Fitting with one rod Fitting with two rods PE MS A PE MS A Beam clamp hanging assembly (*) The Loads depends of type of assembly. Please view the below pictures. 25 NS NS KG KG 2000 N 950 N NS KG 2000 N ≥ 30º 45º E.B. N Ref. (*) 67020048 Material: Steel Working temperature range: -50 ºC / +150 ºC Weight in kilos N= Load capacity per support in Newtons as per Standard UNE-EN 61537 90 /u 0.34 Pack unit 1 Pack unit 3320 A T H.D.G. 2 rods 25 25 P.G. A 1 rod NS KG NS 2500 N 700 N KG NS KG 800 N E.B. Electrolytic Bichromate UNE - EN 12329 P.G. Pre-galvanised UNE - EN 10142 H.D.G. Hot-dip galvanised UNE - EN-ISO 1461 PEMSA-219-91-108-REV 27/11/09 11:48 Página 1 Examples of assembly (A) Fitting with one rod LAYING + EASY CABLE ME SAVING + ASSEMBLY TI 1 3 I PE MS A 1 II 4 4 TURN & CLICK Safety plug included for better performance on widths 200-400 2 3 3 NOTE! I II Safety plug included! (B) Fitting with two rods 5 5 PE MS A 4 6 1 Threaded rod M10 (page 88) 2 Safety plug 3 Hexagonal nut M10 + washer (page 107) 4 Mesh channel (page 90) 5 Threaded rod M8 (page 88) 6 Hexagonal nut M8 (page 107) Cost comparison (A) (B) 40 100 91 PEMSA-219-91-108-REV 27/11/09 11:48 Página 2 Fitting to ceiling Omega System ❶ Bending moment 1 ❷ Bending moment 2 ❷ Vertical Force 340/760 N 2100 N 3370 N 3370 N - 120 Nm 410 Nm 410 Nm - 110 Nm 150 Nm 150 Nm 100 page 94-95 page 94-95 page 94-95 page 94-95 150 page 94-95 page 94-95 page 94-95 page 94-95 200 page 94-95 page 94-95 page 94-95 page 94-95 300 page 94-95 page 94-95 page 94-95 page 94-95 400 page 94-95 page 94-95 page 94-95 page 94-95 TRAY WIDTH: 500 600 ❶ Values obtained from test according to the UNE-EN 61537 standard, with a safety coefficient of 170% without ever reaching the collapse point. Guaranteed only for our hanger with security plug and supports reinforced with the PEMSA structural reinforcement. 92 PEMSA-219-91-108-REV 27/11/09 11:48 Página 3 reinforced pendant bracket 3780 N 4270 N 7270 N 3780 N 360 Nm 930 Nm 930 Nm 360 Nm 430 Nm 730 Nm 730 Nm 430 Nm REINFORCED SUPPORTS GREATER LOAD-BEARING CAPACITY page 96-97 page 96-97 page 96-97 page 96-97 page 96-97 page 96-97 page 96-97 page 96-97 page 96-97 page 96-97 page 96-97 page 96-97 page 96-97 page 96-97 page 96-97 page 96-97 page 96-97 page 96-97 page 96-97 page 96-97 page 96-97 page 96-97 NOTE!! E FIT SUITABL ❷ Values obtained in accordance International Standard UNE-EN 61537 L! (Section H) relating to the information for safe installation of trays with PLUGS IN THE WAL horizontal supports. (See page 111) 93 PEMSA-219-91-108-REV 27/11/09 11:48 Página 4 Omega ceiling bracket N P.G. A Ref. Pack unit 100 62022103 0.42 62032103 0.44 4 D PA /u 760 960 150 62022153 0.62 62032153 0.66 4 800 200 62022203 0.67 62032203 0.72 4 650 300 62022303 0.82 62032303 0.86 4 340 400 62022403 0.94 62032403 0.99 4 D PA NTE 200 TE Ref. O N TA TE H.D.G. /u ø7x20 50 11 A ● Including Omega plug (preassembled) and Omega protector. ● Guarantees and improves the performance of the OMEGA SUPPORTS. ● Makes fitting easier and aids proper fitting of the support. Omega pendant bracket P.G. A 50 Ref. H.D.G. /u Ref. 62021303 0.42 62031303 0.45 5 400 62021403 0.63 62031403 0.67 5 500 62021503 0.70 62031503 0.74 5 600 62021603 0.84 62031603 0.88 5 A 11 94 P.G. Pack unit 300 Including Omega plug (preassembled) and new Omega protector. ø7x20 Material: Steel Working temperature range: -5 ºC / +90 ºC Weight in kilos N= Load capacity per support in Newtons as per Standard UNE-EN 61537 /u Pre-galvanised UNE - EN 10142 H.D.G. Hot-dip galvanised UNE - EN-ISO 1461 PEMSA-219-91-108-REV 27/11/09 11:48 Página 5 Examples of assembly 4 Rejiband Security 200 1 Pemsa A SM EP 100/400 LOAD According to Omega Ceiling bracket table. 300/600 1 2 Rejiband Security Pemsa 100/400 Vertical Force 2100 Bending Moment 1 120 Bending Moment 2 110 SA M PE 6 5 1 300/600 4 2 Rejiband Security Pemsa 100/400 Vertical Force 3370 Bending Moment 1 410 Bending Moment 2 150 5 1 3 SA M PE 300/600 4 3 6 Rejiband 3 1 2 3 4 5 6 M10x35 screw+washer (page 107) M10x20 screw+washer+nut (page 107) M10x60 screw+washer+nut (page 107) Safety plug Omega bracket 100 (page 34) Omega Click bracket 100/300 (page 34) Rejiband Security 4 Pemsa 100/400 Security Pemsa 100/400 Rejiband Security Pemsa 100/400 Vertical Force 3370 Bending Moment 1 410 Bending Moment 2 150 95 PEMSA-219-91-108-REV 27/11/09 11:48 Página 6 Heavy duty pendant drop N BM 1 BM 2 H.D.G. A Ref. 150 Pack unit 3780 360 430 500 67030660 1.51 1 3780 360 430 1000 67030661 2.47 1 N BM 1 BM 2 A ø12x20 80 A /u 115 Double heavy duty pendant drop H.D.G. Ref. 150 Pack unit 4270 930 730 500 67030662 2.48 1 4270 930 730 1000 67030663 4.40 1 N BM 1 BM 2 A ø12x20 80 A /u 115 Heavy duty pendant channel 21 A P.G. Ref. 41 /u ø 8,5 50 3780 360 430 500 67030646 0.87 1 3780 360 430 1000 67030647 1.76 1 20x11 Heavy duty pendant boss 140 47 P.G. 106 108 Ø 12x20 Ref. 67030645 /u 0.62 Pack unit 1 106 Material: Steel Working temperature range: -50 ºC / +150 ºC Weight in kilos N= Load capacity per support in Newtons as per Standard UNE-EN 61537 96 Pack unit P.G. Pre-galvanised UNE - EN 10142 H.D.G. Hot-dip galvanised UNE - EN-ISO 1461 PEMSA-219-91-108-REV 27/11/09 11:48 Página 7 Examples of assembly 1 5 3 2 4 3 2 1 M8x60 screw+nut+serrated washer (page 107) 2 M10x20 screw (page 107) 3 Channel nut (page 104) 4 Heavy duty cantilever (page 84) 5 Heavy duty pendant channel (page 96) 97 PEMSA-219-91-108-REV 27/11/09 11:48 Página 8 8 5 10 4 9 6 1 3 7 1 Inducanal (page 99) 2 Central hanging plate 7 (page 100) 3 Threaded rod M6 (page 100) 4 Joiner 60 (page 100) 5 DIN 603 M6x12 screw (page 107) 6 90º bend (page 100) 7 Universal bracket (page 100) 8 Cover (page 100) 9 Omega bracket (page 34) 10 M6 serrated hexagon flange nut (page 107) 98 2 PEMSA-219-91-108-REV 27/11/09 11:48 Página 9 B S A ø8x20 90 30 ø23 3000 ø21 120 110 100 90 Ref. 3600 60x60 80 P.G. AxB 75122060 /u 1.11 Kg S 70 Pack unit 60 24 50 Recommended distance between supports: 2 m. 40 1.5 1.6 1.7 1.9 2.0 Metres 60 Safety edge 1.8 Wellfinished side/edge Self fix lid cover Push Material: Steel Working temperature range: -50 ºC / +150 ºC Weight in kilos P.G. Pre-galvanised UNE - EN 10142 Values obtained from test according to the UNE-EN 61537 standard, with a safety coefficient of 170% without ever reaching the collapse point. Tray section joints be situated at a support distance of between L/4 and L/5, L being the distance between supports. At completed tray extreme ends, tray support distance should be a maximum of 0,4L without any type of joint. 99 PEMSA-219-91-108-REV 27/11/09 11:48 Página 10 Inducanal cover P.G. A /m m 0.47 24 Ref. 73021060 60 Length 3 m. A Joiner P.G. A Ref. 7 71022005 60 Central hanging plate 7ø 7x14 0.101 50 E.G. Type 35 Ref. Pack unit /u 67010144 M6 Pack unit /u 0.032 20 59 Threaded rod M6 A N E.G. AxB Ref. B Universal bracket (Pemsaband) E.B. /u Ref. 67010140 0.12 67020140 0.12 50 1980 M6x1000 67010141 0.24 67020141 0.24 50 P.G. H.D.G. Ref. /u 70420911 0.175 Ref. /u 70430911 0.194 Pack unit 10 For fixing BOXES, use M-5 bolts 0 17 90º Bend B P.G. AxB Ref. A 60x60 /u 71022062 90º Bend cover Ref. 60 0.13 Pack unit 1 P.G. A 72020062 /u 0.027 Pack unit 1 A Material: Steel Working temperature range: -50 ºC / +150 ºC Weight in kilos 100 Pack unit 1980 M6x500 109 ø7x20 /u E.G. E.B. P.G. H.D.G. Electrogalvanised UNE - EN 12329 Electrolytic Bichromate UNE - EN 12329 Pre-galvanised UNE - EN 10142 Hot-dip galvanised UNE - EN-ISO 1461 PEMSA-219-91-108-REV 27/11/09 11:48 Página 11 Examples of assembly 3 1 2 Press fit assembly (no bolts no nuts required). Cover remains fixed even in vertical position. 4 2 1 1 6 5 1 7 2 8 1 M6 serrated hexagon flange nut (p 107) 2 DIN 603 M6x12 screw (page 107) 3 Joiner 60 (page 100) 4 Threaded rod M6 (page 100) 5 Central hanging plate 7 (page 100) 6 Universal bracket (page 100) 7 90º bend (page 100) 8 Omega bracket (page 34) 101 PEMSA-219-91-108-REV 27/11/09 11:48 Página 12 Supports & structures In any industrial, electrical, pneumatic, hydraulic or other such installation, the support system (supports and structures) is at least as important as the conduits themselves. If the support system is not suitable, the whole installation will fail, with the attendant service cost. To avoid this, and to achieve a satisfactory installation from the outset, Pemsa has developed a comprehensive range of SUPPORTS according to the EN 61537 standard, with a STRUCTURE system made in steel with Sendzimir and Hot-dip Galvanisation protection. This range, with its accessories, makes weld-free setting up and modifying easy for all the structures commonly found in such industrial installations. PA TE D O PA N TA D TE NTE 102 PEMSA-219-91-108-REV 27/11/09 11:48 Página 13 List of supports and usage modes WALL MOUNTING CEILING MOUNTING LOAD * Use Page LOAD * Use 250 R 32 250 R Page 32 40 R 510 (1) R 1760 2760 32 R 580 1180 (2) 40 P R 34 40 1275 82 P 88 P 88 R 1210 2530 (2) 36 P 890 (2) 40 84 M6 M8 M10 R 1210 2060 R 36 P 1890 5000 84 R 40 P 88 I 100 R 40 R 1210 2060 (2) 36 P 700 84 R 1840 2490 R 36 P (1) 1760 3320 42 P 84 R R Rejiband P Pemsaband I Inducanal * Per support, in Newtons, as per IEC 61537 1760 4890 (1) 42 P R 340 960 (1) 90 46 P R 2100 3370 94 46 P R (1) Security plug included (2) With structural reinforcement 90 94 48 3780 P 96 103 PEMSA-219-91-108-REV 27/11/09 11:48 Página 14 Heavy duty channel 41x41 ø11x20 50 P.G. e mm Ref. 2.5 67030053 e mm Ref. 2.5 67030052 H.D.G. /u 2.61 S.S. 316 Ref. 67030057 /u 2.64 Ref. 67060057 /u 2.53 Pack unit 3 11 41 e 22 41 Length 3 m. Heavy duty channel 41x21 ø11x20 50 11 P.G. H.D.G. /u 1.77 S.S. 316 Ref. 67030055 /u 1.80 Ref. 67060055 e 20,5 22 41 Length 3 m. Light duty channel 41x41 Ø11x20 50 11 41 P.G. e mm Ref. 1.5 67030074 /m m 1.61 3 /m m 1.14 3 e 22 41 Length 3 m. Light duty channel 41x21 Ø11x20 50 P.G. e mm Ref. 1.5 67030075 11 20,5 e 22 Length 3 m. Channel nut 41 E.G. Type 67020055 0.020 - - Pack unit 100 67020058 0.025 67060058 0.03 100 Ref. M6 M10 Material: Steel Working temperature range: -50 ºC / +150 ºC Weight in kilos N= Load capacity per support in Newtons as per Standard UNE-EN 61537 104 S.S. 316 /u Ref. /u E.G. P.G. Electrogalvanised UNE - EN 12329 Pre-galvanised UNE - EN 10142 H.D.G. S.S. Hot-dip galvanised UNE - EN-ISO 1461 Passivated stainless steel AISI 316 /u 1.73 Pack unit 3 PEMSA-219-91-108-REV 27/11/09 11:48 Página 15 TECHNICAL DATA Y Axis x-x Dimensions Jx cm X X 4 Wx cm Axis y-y 3 r xx Jy cm 4 Wy cm3 r yy 41x41x2.5 6.11 3.00 1.42 9.15 4.41 1.75 41x21x2.5 0.95 0.95 0.71 5.29 2.55 1.66 r xx Jy cm Y Y Axix x-x Dimensions Jx cm X X 4 Wx cm Axis y-y 3 4 Wy cm3 r yy 41x41x1.5 4.25 2.03 1.45 6.10 2.94 1.75 41x21x1.5 0.73 0.67 0.74 3.60 1.73 1.64 Y J - Moment of inertia W - Section modules r - Radius of gyration Q1 L 41x41x2.5 41x21x2.5 41x41x1.5 41x21x1.5 Q1 Q2 Q1 Q2 Q1 Q2 Q2 Q2 500 719 3620 230 2010 308 3050 200 1850 1000 360 2900 78 1065 79 2010 55 1230 1500 206 2160 35 570 35 - 25 - 2000 115 1580 20 - 20 - 13 - L Q2 L mm L - Distance between supports in mm. L Q1 - Uniformly distributed load expressed in DN=kg for f= 250 Q2 - Máximum load on column expressed in DN=kg 105 PEMSA-219-91-108-REV 27/11/09 11:48 Página 16 Accesories for assembly on channel. 1 2 3 4 5 6 7 8 9 M Description Finish /u Pack unit 1 Angle bracket 67030201 H.D.G. 0.15 1 2 Angle bracket 67030202 H.D.G. 0.32 1 3 Splice plate N3 67030205 H.D.G. 0.24 1 4 Tee plate N4 67030203 H.D.G. 0.31 1 5 Tee plate N5 67030204 H.D.G. 0.45 1 6 Clamp 21 67030206 H.D.G. 0.29 1 7 Clamp 41 67030207 H.D.G. 0.36 1 8 Channel floor boss 67030064 H.D.G. 1.45 1 9 Channel beam clamp 67030101 E.G. 0.35 2 Material: Steel Working temperature range: -50 ºC / +150 ºC Weight in kilos N= Load capacity per support in Newtons as per Standard UNE-EN 61537 106 Ref. E.G. Electrogalvanised UNE - EN 12329 H.D.G. Hot-dip galvanised UNE - EN-ISO 1461 PEMSA-219-91-108-REV 27/11/09 11:48 Página 17 Screws E.G. Washer Type Ref. E.B. /u Pack unit 0.002 67020063 0.002 67060063 0.002 100 67020061 0.002 67020013 0.004 67060064 0.002 100 PASSIVATED /u M8 67020084 0.001 100 67020086 0.001 100 E.G. Type Ref. M10x20 /u 67020065 Hexagonal cone point screw 0.03 Ref. M10x20 E.G. /u 67020098 50 Pack unit 0.023 E.B. Ref. Pack unit E.B. Type /u Pack unit M10 Allen screw 10 H.D.G. /u Ref. S.S. 316 /u Ref. /u Pack unit M6x12 67010099 0.005 - - 67030099 0.005 - - 100 M6x20 67010100 0.007 67020100 0.007 67030100 0.007 67060100 0.007 100 Hexagonal set screw E.G. Type Ref. Serrated hexagon flange nut Type M6 Hexagonal nut 64010059 0.003 67020054 0.008 100 67020092 0.040 100 M10x20 67020059 0.023 100 M10x35 67020077 0.029 100 M10x60 67020010 0.042 100 Ref. 64020059 H.D.G. /u 0.003 E.G. Type Ref. Working temperature range: -50 ºC / +150 ºC Pack unit M8x65 E.B. /u /u M6x15 E.G. Ref. Weight in kilos /u 67020083 Ref. Ref. Ref. M8 Type Type /u M10 Serrated washer Shoulder screw c/DIN 603 S.S. 316 Ref. Ref. 64030059 S.S. 316 /u 0.003 E.B. /u Ref. Ref. 64060059 /u 0.003 Pack unit 50 S.S. 316 /u Ref. /u Pack unit M8 67020095 0.005 67020062 0.005 67060062 0.005 100 M10 67020079 0.008 67020014 0.008 67060014 0.008 100 E.G. E.B. Electrogalvanised UNE - EN 12329 Electrolytic Bichromate UNE - EN 12329 H.D.G. S.S. Hot-dip galvanised UNE - EN-ISO 1461 Passivated stainless steel AISI 316 107 PEMSA-219-91-108-REV 27/11/09 11:48 Página 18 Examples of assembly 2 1 3 4 5 1 1 1 Highly reinforced rail (p. 104) 2 Clamp 41 (page 106) 3 M8/10 rod (page 40) 4 M10x20 Allen screw (page 107) 5 Vertical support (page 106) 6 M10 rail nut (page 104) 7 Angle Bracket (page 106) 6 7 1 7 5 108 5 5 PEMSA-219-109 AL FINAL-REV- 27/11/09 11:51 Página 1 Recommendations for the correct installation of cable trays (BS-EN 61537, BS 20.460, REBT 2002, ITC-BT 20 and 21) Standards 1.- LOCATION 3.1.- DISTANCE BETWEEN TRAYS Must NOT be installed under water, steam, gas, tubing, etc. For correct cable ventilation, at least the minimum distance indicated in the drawing must be maintained. Security Pemsa Rejiband Security Pemsa Rejiband Security Pemsa Rejiband Security Pemsa 300 Rejiband 2.- PROTECTION 22 5 The trays are for conveying cables, NOT FOR PROTECTING THEM. In the majority of installations, the characteristics of current cables makes it unnecessary to protect them. If necessary, use the appropriate covers. 3.- VENTILATION Cables heat up while being used due to the passage of current. At the same ambient temperature and power, this heating can increase according to the type of tray being used (open or closed). With less ventilation, a greater cable cross section is required and, as a result, cost increases. Maximum ventilation: rejiband® or ladder-type trays. Medium ventilation: perforated metal sheet trays. Minimum ventilation: solid metal sheet trays. 3.2.- DISTANCE TO WALLS When trays are fastened to a wall on supports, a separation of at least 20 mm must be maintained between the tray and the wall in order to allow for cable ventilation. At Pemsa, all wall supports have a total length of 50 mm more than the width of the tray to be installed, thereby complying with legislation in force. Example: A 300 support has a length of 350 mm. 50 The use of solid bottom trays is, in most cases, due to aesthetic criteria. L 109 PEMSA-219-109 AL FINAL-REV- 27/11/09 11:51 Página 2 4.- MARKINGS Trays should facilitate labelling through markings. les cab a t da ce) Voie 7/3 any Lin nt 7 omp C a ( Pl pemsa 5.- SUPPORTS These are fundamental in a tray installation. If they are not suitable, the whole installation will be flawed. The following factors should be borne in mind when choosing them: • The load-bearing capacity of the support. • Its corrosion resistance. • Ease of installation. The recommended distance between supports or bearing points is normally 1500 mm. When this distance is changed, the performance of the tray changes. When attaching the supports to the wall or ceiling, particular attention must be paid to the fixings used, making sure it is right for the characteristics of the building. The use of CHANNEL (page 104) gives better load distribution, whilst also facilitating adjustment. 0 150 0 150 0 150 6.- RECOMMENDED POSITIONS FOR SUPPORTS ( Same for rejiband® steel wire cable trays. ) Rejiband 300 máx. (400/600) 150 máx. (100/300) Only heavy loads Rejiband 300 máx. (400/600) 150 máx. (100/300) Only heavy loads Rejiband 300 máx. (400/600) 150 máx. (100/300) Rejiband 300 máx. (400/600) 150 máx. (100/300) 110 PEMSA-219-109 AL FINAL-REV- 27/11/09 11:51 Página 3 400 max. Rejiband 300 max. (400/600) 150 max. (100/300) 400 max. 400 max. 400 max. Rejiband 300 max. (400/600) 150 max. (100/300) 400 max. 400 max. 0 40 ax. m 400 max. 7.- TRAY AND SUPPORT DEFORMATION The weight of cables deforms trays, the most visible point being in the centre between supports. L The allowable value (F) of deformation is purely aesthetic, always taking care not to exceed the values indicated by the manufacturer, which, in accordance with international standard IEC 61537, should be as follows: F max=L/100 mm. F L F On supports, maximum F deformation and twisting occurs at the ends. The standard requires that the maximum F = L/20 mm. The deformation, F is called deflection, and is expressed in mm. 8.- INFORMATION FOR A SAFE INSTALLATION OF PENDANTS WITH CANTILEVER BRACKETS (ANNEX H. IEC 61537) M1 The SWL (Safe Working Load) of a pendant with cantilever brackets is determined by the following conditions: F a. The connection of the pendant to the ceiling; defined by the Bending Moment 1 (M1). b. The connection of the cantilever bracket and the pendant; defined by Bending Moment 2 (M2). M2 c. The pendant itself by bending; defined by resulting Vertical Force (F). Installation of the assembly (including the pendant) is considered to be safe if all the following are satisfied. M1 Nm 1. M1 and F are in the safe area of the figure. 2. The applied load on each bracket is lower than the corresponding SWL declared for test. (paragraph 10.8.1 IEC – 61537). 3. The Bending Moment of the pendant itself is lower than the SWL for the pendant length. FN 111 PEMSA-219-109 AL FINAL-REV- 27/11/09 11:51 Página 4 9.- CONNECTORS The trays are shipped in pre packed lengths of 2 or 3 meters. The pieces called CONNECTORS are used for connecting them. For mechanical purposes, the weakest points in a tray installation are the joints . Only the use of the right number of CONNECTORS in the right positions as recommended by the manufacturer can ensure that the entire system will perform satisfactorily. The ideal spot for employing the CONNECTOR is at L/5 from the nearest support. Fitting the CONNECTORS between L/4 and L/5 is the most advisable approach. L ALL THE LOAD AND PERFORMANCE VALUES GIVEN IN THIS CATALOGUE WERE OBTAINED FROM TESTS CARRIED OUT IN ACCORDANCE WITH INTERNATIONAL EN 61537 STANDARD It is often found that similar trays from different manufacturers give different values. This may be due to the load tests not being carried out in accordance with this standard. For proper comparisons to be made between two similar trays from different manufacturers, check that the values given were found under equivalent test conditions. L/5 11.- EARTHING (ELECTRICAL CONTINUITY) All metal tray systems must have proper electrical continuity. However, to ensure safety, it is advisable to make an earth connection using a suitable conductor for each part of the system. L/4 L This CANNOT be done on painted or epoxy-coated trays without removing the protective layer at that point and at the join-points between the various lengths, which will inevitably lead to oxidisation WITHOUT ENSURING safety. L/5 L/4 The CONNECTORS should NOT be fitted at point L/2 (half-way between the supports), or on the supports. When L=1.5 meters, which is the commonest case, the use of 3-meter lengths ensures the best placing of the joints, unlike using 2-meter lengths. L L/2 NO L When the trays have to go through a wall, the trays should have a clear space of approximately 100 mm on each side. The earth connection must always be maintained. NO 0 10 L/2 0 10 10.- LOAD-BEARING CAPACITY This is the load (uniformly distributed, NOT concentrated) that a tray can safely cope with. It is expressed in kilos or kg per running meter, in the form of graph curves or tables. 1 kg = 9.81 Newtons The values are obtained through experiments carried out in accordance with the pertinent standards. 112 12.- THROUGH-WALL MOUNTING If the characteristics of the two rooms separated by the wall are different and may pose risks associated with moisture, gas or fire, the hole in the wall should be blocked off using suitable systems from among those available. PEMSA-219-109 AL FINAL-REV- 27/11/09 11:51 Página 5 Technical Information According to IEC 61537 Standard CLASSIFICATION ACCORDING TO IEC 61537 STANDARD Material: Flame Spreading Resistance: Electrical Continuity Characteristics: Electrical Conductivity Characteristics: Coating Material: Metallic Non Flame Spreading With Continuity With Conductivity Metallic Transport, store, installation and application temperature range: Minimum: -40 ºC Maximum: +150 ºC Perforation base Area Classification: Pemsaband® Solid: Pemsaband® Standard: Rejiband®: Classification A Classification B Classification D Impact Resistance: Up to 20 J Useful dimensions of the Rejiband Tray (wide and height in mm) Flange Useful height Width Useful wide 35 26 60 42.5 60 50 100 82.5 100 90 150 132.5 200 180.5 300 280.5 400 380.5 500 480.5 600 580.5 Torque settings for screwed connections (in Nm) Hardness Max. Torque Setting According to ISO 8.8 898-1/898-7 According to ISO 4.6-4.8 898-1/898-7 According to ISO 4.8 898-1/898-7 According to ISO 4.6-4.8 898-1/898-7 Type of Screw Allen M1Allen Screw M10x20 Ex.Cone point M10x20 C/DIN 603 M6x12/20 Ex.Cone point M6x15/x85 and M10x10/30/58 Choosing the right tray and support system You need to know the following factors in order to select a tray system: • The weight and diameter of the cables intended for use in the installation, and in future extensions. • Any non-distributed loads planned (lamp fittings, electrical boxes etc.) • The distance that can be allowed between supports or bearing points. • The corrosion protection needed. • The nature of the installation (open, closed etc.) • The method of installation (wall, ceiling, floor etc.) • The need for earthing. • Electromagnetic compatibility TRAY SIZE. When the cables involved are known, check their weight per meter and cross-section in the manufacturer’s catalogue. Add 30-50% to each of these values to allow for future extensions. THE TOTAL CROSS-SECTION NEEDED is found by adding up all the cross-section values of the cables planned and any future cables, plus the filling coefficient. The calculation involved is: S= K (100+a) ∑n 100 Where: S = total section needed in mm2 K = fill coefficient: 1.2 small cables 1.4 power cables a = space reserved for future extensions (30-50%) ∑n = The sum of the sections of the cables to be installed in the cable tray. When the value of “S” is known, the total weight per meter of the cables “P” is found from the catalogue, 113 PEMSA-219-109 AL FINAL-REV- 27/11/09 11:51 Página 6 increasing the value by that same percentage. This value “P”, in kilos/meters, is converted into Newtons, since that is the unit used in the rack load-capacity graphs. The calculation for “P” gives 29.46 kg/m, which when increased by 30% gives 38.3 kg/m. Converting this to Newtons gives 375.3 Newtons per meter. Conversion: Check on page 15 or 62 whether the cable tray chosen on the grounds of “S” have this load-bearing capacity. 1 kilo~9.8 Newtons With reference to these S and P values, find the most suitable S and P values in the tray catalogue, erring on the side of excess. If an exceptional load is planned at some point in the installation, select a tray with higher performance values for there. For example: Find the tray section needed for installing these cables: 5 cables, 4x35 10 cables, 4x25 4 cables, 4x25 2 cables, 4x4 mm. kg.m. mm2 26.8 24.1 23 14.5 1.86 1.42 1.31 0.36 563.8 456 415.2 165 4x35 4x25 3x25 4x4 “S” is calculated by applying the formula: K (100+a) S= ∑n The calculation for ∑n will be: = 2.819 mm = 4.560 mm2 = 1.661 mm2 = 330 mm2 They must have sufficient load-bearing capacity to withstand safely the system of trays plus the accessories selected, and must have the same degree of protection against corrosion. K = 1.4 and a = 30%, will be: 9.370=17.053 mm2 100 Find the nearest value on page 12 or 56, erring on the side of excess, which will correspond to a cable tray: REJIBAND, 400 x 60, total section 18.610 mm or PEMSABAND, 400 x 60, total section 22.540 mm2 2 114 For more information, see the chapter on this (page 115). There are other types of plastic coverings based on various products: PVC, Polyethylene, Polypropylene, Epoxy resin etc. These are more attractive in appearance, but give results that are very inferior to zinc-based coatings. They are fragile, and the range of working temperatures is much narrower than zinc. SELECTING THE TYPE OF SUPPORT. Once the tray has been chosen, suitable supports in terms of the type and method of installation must be chosen. The section that tray must have, where 1.4 (100+30) P.G. Sendzimir galvanizing E.G. Electrogalvanizing E.B. Electrogalvanized bichromate (Yellow) H.D.G. Hot-dipgalvanized S.S. Stainless steel METHOD OF INSTALLATION. On the wall, ceiling or the floor. See Rejiband, pages 30-31-38-39-44-45. Pemsaband, pages 80-81-86-87-92-93. 2 9.370 mm2 S= To remedy this, various surface-treatment processes based on zinc are used. TYPE OF INSTALLATION. Open, with or without covers, and closed. The latter are used when greater mechanical protection is needed. In this case, the crosssection of the cables must be increased to offset the poorer ventilation. 100 5x563.8 10x456 4x415.2 2x165 This material oxidises easily, causing significant economic losses. In the case of trays, there may also be quality of service problems. The commonest and most successful in industry are, in order of efficacy: mm2 mm2 mm2 mm2 The following is found in the cable manufacturer’s catalogue: Cable Cable Cable Cable PROTECTION AGAINST CORROSION Most tray systems available are made of steel. Pemsa gives the load-bearing capacity of all its supports in accordance with standard IEC 61537, and the capacity of their protective finish. When the Safe Working Load (SWL) for the rack chosen is known in Newtons per meter, the support must be able to withstand the value of this SWL x L, where: L = the distance between the supports in meters. PEMSA-219-109 AL FINAL-REV- 27/11/09 11:51 Página 7 Surface treatment to prevent corrosion CORROSION. Corrosion is an electro-chemical phenomenon that arises from contact between two different metals, or a metal and the environment (air, water, gases) surrounding it. All metals are liable to corrosion to some extent. The end result of the corrosion process is the total destruction of the metal affected. In view of the high costs stemming from corrosion, there are various industrial coatings that can be applied on the surface in order to retard the appearance of corrosion. The duration of the protection achieved depends on the thickness of the protective coating, expressed in microns (1 micron = 0.001 mm), the type of coating used, and the aggressiveness of the environment. TABLE I Estimated service life in years of the Thickness protective coating in different atmosin microns pheres... 30 40 80 100 Industrial Marine Urban Rural 7-14 9-18 5-10 7-15 13-25 15-35 13-28 20-40 4-12 6-18 11-33 14-40 The thickness of the coating applied varies from 8 to 12 microns - see table II. The Standard recommends applying a chrome-conversion layer (UNE 112-050). Recommended for indoor installations in a dry atmosphere with no aggressive contaminants. BYCRO-E.B. Electrogalvanized bichromate (yellow colour) BS - EN12329 This involves the above process plus subsequent treatment that improve the anti-corrosion performance - see table II. The thickness of the coat applied is 8-12 microns. The process as used by Pemsa involves no CYANIDE and no CHROME VI. Recommended for use in dry, contaminant-free atmospheres. Better performance than P.G. and E.G. H.D.G. Hot-Dip galvanising UNE - EN ISO 1461 Used for all kinds of products. It involves immersing the individual pieces to be protected into a bath full of zinc at 450 ºC after the parts have been machined. The average thickness of the protective coating is 70 microns. In the case of steel, the most highly developed industrial process is zinc coating. All the steel products made by Pemsa are protected by one of the following coatings: P.G. Sendzimir galvanising UNE - EN 10142 (NOT TO BE CONFUSED WITH HOT-DIP GALVANIZING) Used solely for protecting sheet metal of below 3 mm in thickness. Produced by dipping the rolls of steel in a zinc bath at 450 ºC. This technique is widely used in the manufacture of barcut parts and stamped parts. The cuts arising in the machining are partially regenerated by the galvanic pair formed by the steel and the zinc. The thickness of the protecting coating is from 8 to 15 microns. Recommended for indoor installations in a dry atmosphere with no aggressive contaminants. E.G. Electrogalvanizing (white colour) UNE - EN12329 This involves protecting parts made of iron and steel electrolytically using zinc. Recommended for outdoor, marine, rural, industrial and aggressive indoor installations. STAINLESS STEELS These are carbon steels alloyed with chromium, nickel, magnesium and molybdenum. The best-known ones are AISI 304 (18/8) and AISI 316. Contrary to widespread belief, these steels ALSO SUFFER CORROSION, though their performance when properly handled is generally much better than any type of protective coating. Their specific behaviour is the result of the chromium and nickel spontaneously generating a film of chromium oxide in the presence of an oxidising environment, this film then preventing subsequent oxidisation. The film is very delicate, and can be broken by blows, machining, welding etc. Stainless steels are easily CONTAMINATED, thus losing their properties, when they are machined with tools that use other types of steel. In such cases, the protective film must be generated by a chemical-attack process. To solve this problem, after the manufacturing work (punching, welding), PEMSA subjects all its REJIBAND S.S. rack and accessories to a special process for regenerating the protective layer known as THERMICRON. 115 PEMSA-219-109 AL FINAL-REV- 27/11/09 11:51 Página 8 A 304 STAINLESS STEEL AISI-304 For guideline purposes, since each installation is different, the following protective coatings can be advised: Suitable for: • Fresh water • Industrial atmosphere • Marine atmosphere • Normal chemical industry • FOOD INDUSTRY (except high temperatures) TABLE III TABLE FOR CHOOSING SURFACE TREATMENTS IN VIEW OF THE ENVIRONMENT Bycro Inox. Inox. EB PG HDG 304 316 TYPE EG Specially recommended for: Indoor B B B B B B • Marine and coastal areas • Aggressive chemical environments • High temperature food industry applications. Indoor, near sea NR P NR B B B P B P B B B A 316 STAINLESS STEEL AISI-316 Outdoor, dry climate Laboratory tests carried out in a salt-spray chamber in accordance with ASTM-B117 produced the following results: TABLE II Corrosion resistance in hours E.B./BYCRO Electrolytic zinc coating, E.G. H.D.G. S.S. Outdoor, near sea NR NR NR P P B Coast NR NR NR P NR B Sulphurous NR NR NR P P B Mineral acids NR NR NR P P B Ammonium NR NR NR P P B Caustic soda NR NR NR P P B birchromate (yellow) 440 Electrolytic zinc coating (white) 290 Organic acids NR NR NR P B B >600 Hydrocarbons NR NR NR P B B Chlorine NR NR NR NR P B B B Hot-dip galvanizing Stainless steel AISI 304 No trace after 450 An approximate way of finding out how laboratory values translate into real-world values is: 1 laboratory hour = 1 week In the case of an industrial marine atmosphere, divide the above results by 2. P Food industry B: Good P P: Possible P P NR: Not recommended Recommended by Pemsa CORROSION E.B./BYCRO 440 E.G. 290 0 50 100 150 200 250 300 HOURS 116 350 400 450 500 PEMSA-219-109 AL FINAL-REV- 27/11/09 11:51 Página 9 Electrical continuity To ensure electrical safety in a cable-carrying tray installation, the installation must have suitable electrical continuity. The design of the joining has decisive importance in the R1 value, as do the material, the surface finish and the method of assembly. This is stipulated in Standard IEC 61537 section 11.1, which gives the pertinent tests for checking this. Contact between different materials or finishes encourages oxidisation, thereby reducing electrical continuity. The same condition may arise through insufficient contact pressure at the join point. This is done in this way: measuring the electrical-resistance values at the most unfavourable point R1 (joining between racks) and R2 (material resistance) measured across two points that are 500 mm apart in the same straight run. YS AND EMBLE TRA DO NOT ASS INISHES IFFERENT F D H IT W S T JOIN The maximum admissible values according to IEC 61537 are: R1< 50 mΩ R2< 5 mΩ R1 In tests performed at Pemsa’s request in the Central Laboratory of the Electrical Engineering Office under number 99 121006 on 10/12/99, involving various samples of rejiband® and pemsaband®., the values given in the following tables were found: R2 G RESISTANCE (mΩ) Rack mm Tigtening torque at connectors R1 R2 3 Nm 0,18 0,79 4 connectors - 1,41 0,79 2 connectors 3 Nm 1,11 1,38 2 connectors - 2,86 1,38 4 connectors 3 Nm 1,18 0,73 4 connectors - 0,39 0,73 100x60 2 connectors 3 Nm 2,57 4,58 100x60 2 connectors 3 Nm 0,27 0,35 3 Nm 0,12 0,22 Connector used and number 4 connectors 600x60 E.B. / BYCRO D AN RITY REJIB SECU REJIBAND 100x60 600x60 D AN RITY REJIB SECU P.G. PEMSABAND Inox 304 H.D.G. D AN RITY REJIB SECU 2 side connectors 400x60 1 central connector 117 PEMSA-219-109 AL FINAL-REV- 27/11/09 11:51 Página 10 Earthing If it is deemed, in view of the installation, to be necessary to have an independent earth conductor, its section must be at least 16 mm2, and must be mounted on the outside throughout the tray system, connected using the right accessories to each length of the installation. A cable-carrying tray system comprises straight lengths and accessories (bends, crossovers, Tee-joints) joined together using suitable fasteners. The electrical continuity in the system ifself (in the case of metal trays), which is necessary to achieve proper earthing and to ensure personal safety, can be adversely affected by a wide range of causes (oxidisation, nuts coming loose, insulating coatings, etc.). To avoid this, it is advisable to install an independent earth circuit by connecting up every single element in the system (trays and accessories) to a suitable sized conductor - with a section of at least 16 mm2. In the case of trays that are painted or coated with epoxy resin, the electrical continuity needed in the system is broken. In such cases, arranging an earth connection is absolutely essential. That is a difficult operation, since it can only be done by removing the protective layer by mechanical means at the earth-connection point. This inevitably creates an oxidisation zone which further hinders the earthing. That is why electrically safe tray systems must be made of metal with metal coating or made solely of insulating material. The earth connection is to be made using the right parts - see rejiband® page 24 or pemsaband® page 72. PE MS A 118 Rejiband Pemsaband page 24 page 72 PEMSA-219-109 AL FINAL-REV- 27/11/09 11:51 Página 11 Electromagnetic Compatibility (CEM) Power supply cables and signal cables can share the same cable conveyance systems (Trays, Channels, etc.). Adequate separation must be provided (by distance or shielding) between power cables and signal cables. Power cables and signal cables must cross at right angles. In order to prevent disturbances, the minimum separation between power cables and signal cables depends on many factors, such as the following: a) The level of immunity from the various electromagnetic interference (surges, overcurrents, lighting impulses, ring waves, continuous waves, etc.) of the equipment connected to the signal cabling system. b) The connection of the equipment to the grounding system. c) The local electromagnetic environment (the simultaneous appearance of disturbances: for example, harmonics added to discharges and to continuous waves). d) The electromagnetic spectrum. e) The distances that the cables run parallel to each other (the coupling zone). f) The kind of cable. g) Cable attenuation against coupling. h) The quality of the connections between the connectors and the cable. i) The type of cable conveyance system and its accessories. Separation between signal cabling and power cabling Distance Without a dividing wall or with a non metal divider(1) Aluminium divider Unshielded power cable and unshielded signal cable 200 mm 100 mm 50 mm ✔ Unshielded power cable and shielded signal cable (2) 50 mm 20 mm 5 mm ✔ Shielded power cable and unshielded signal cable 30 mm 10 mm 2 mm ✔ Shielded power cable and shielded signal cable (2) 0 mm 0 mm 0 mm ✔ Type of instalation Steel divider 1) It is assumed that in the event of a metal divider, the design of the cable conveyance system will provide shielding attenuation that is approximate to the material used in the divider. 2) Shielded signal cables must comply with the EN 50288 series. 119 PEMSA-219-109 AL FINAL-REV- 27/11/09 11:51 Página 12 Electromagnetic Compatibility (CEM) Metal systems for cable conveyance: trays, channels, etc. Metal systems for cable conveyance should always be connected to the local ground at both ends. Over long distances (more than 50 m), additional connections to the ground systems are recommended at irregular intervals. All ground connections should be as short as possible. Non-metal systems for cable conveyance: trays, channels, etc. In order to improve the EMC behaviour of non-metal systems for cable conveyance, when devices connected to the wiring systems with unshielded cables are not affected by low frequency disturbances, it is advisable to add a cable to the cable conveyance system, such as a parallel ground conductor connected at both ends to the local ground system. Connections should be made to metal parts with low impedance (for example, to a large piece of the sheet metal of an electrical cabinet). The parallel ground conductor should be designed to resist the common mode and fault currents. Grounds and equipotential connections Overview. The basic purposes of connection and grounding applicable to unshielded and shielded wiring systems are as follows: - Safety: to limit contact voltage and provide a return path in the event of a fault to ground; - EMC: to have zero potential and equipotentiality, which provide a shielding effect. Source: UNE-EN 50174-2 Rejiband installed with a divider. 120 PEMSA-219-109 AL FINAL-REV- 27/11/09 11:51 Página 13 Pemsa Metal Tray Systems: Behaviour in the event of fire: A1 (the Safest: Non Combustible) New European Classification System in compliance with the Directive 89/106/EC, according to the Fire Behaviour of the Materials. Classification (*) 1 A1 Non combustible 2 A2 Slightly combustible 3 B ““ 4 The safest Additional Classification Less Safe (in decreasing order) C Smoke Production (S) Smoke Density Combustible Flaming droplets/particles (D) 5 D ““ 6 E ““ 7 F No performance determined - (*) In accordance with EN 13501-1:2002 BEHAVIOUR IN THE EVENT OF FIRE Smoke Opacity Smoke Toxicity Contained Halogens No Smoke No Smoke No Smoke NO COMBUSTIBLE / FIRE RESISTANT Reduced Smoke Emission Reduced Opacity of Smoke Smoke with Low Toxic Particles Level NO COMBUSTIBLE / FLAME PROPAGATOR Dangerous Smoke Emission High Opacity of Smoke Smoke with Toxic Particles Level YES MATERIALS Directive 89/106/EC Steel Trays NON-COMBUSTIBLE Halogen-free cables P.V.C. Smoke Emissions The Rejiband and Pemsaband Metal Tray (A1) systems guarantee safety in that they do NOT emit toxic gases or halogens, they do NOT emit opaque smoke (luminous transmittance), they do NOT emit corrosive gases and they do NOT propagate fire. MAXIMUM SERVICE TEMPERATURES OF CABLES AND TRAYS (*) Conventional PVC Cables 70ºC Halogen-free Cables 90ºC PVC Trays 60ºC Rejiband and Pemsaband Metal Trays 150ºC (*) For cables and trays, data according to manufacturer catalogues. Rejiband and Pemsaband Metal Trays do not limit the maximum service temperature of halogen-free cables. 121 PEMSA-219-109 AL FINAL-REV- 27/11/09 11:51 Página 14 Fire Resistance rejiband ® Safety is a growing concern within electrical installations. In the event of a fire the behaviour of electrical equipment, when exposed to high temperatures, determines whether the installation achieves a certain safety level. rejiband® wire mesh cable tray complies with these requirements with a number of features and properties as described in the E90 Certification. rejiband® wire mesh cable tray is manufactured in accordance with the requirements and tests of the product standard IEC 61537 "Cable Tray and Cable Ladder Systems". So far this standard has not yet covered the fire risks and fire resistance. DIN 4102-12 “Cable Tray and Cable Ladder Systems” E30 E60 When studying the properties of rejiband® wire mesh cable tray against fire, Pemsa has used the German Standard DIN 4102-12 which is the main reference in other European countries. This standard tests the complete installations, in order to evaluate the structural integrity of the assembly and how the components react when exposed to fire. A 3m length of wire mesh tray, accessories and power cables are the subject of the test. According to the final results, the certification may be issued at three different levels: Table 1. Standards. STANDARDS E30 E60 E90 Time Temperature 30 min. 840 ºC E660 min.0 950 ºC E990 min.0 1000 ºC0 The purpose of this test is to validate the correct operation of the electrical system and to ensure that critical services (fire suppression system, emergency lighting, ventilation and other basic installations) remain functional for long enough to organise evacuation in the event of fire. 122 PEMSA-219-109 AL FINAL-REV- 27/11/09 11:51 Página 15 Fire Resistance Test Set-up Figure 1: General View Of The Assembly The test set-up consisted of a 3m length of wire mesh tray, including joints and accessories, supported on brackets at intervals of 1.2m. The power cables, up to 1kV, should be fire resistant at the same or higher level than halogen free, high safety cables. The wire mesh tray was then loaded with chains to simulate the cable weight and other standard conditions of the test. During the test, a standardised temperature vs. time curve is imposed in the test oven, obtaining the 3 levels of certification and their corresponding times and temperatures as shown on table 1. The results prove that the cables maintain electrical continuity during the test, and therefore the operational integrity of the installation is maintained. As the test was progressing, both cables and trays were damaged by the high temperatures as defined in DIN 4102-12. Trays are deformed but maintain their support function. The cable sheathing starts to burn causing risk to the correct functioning of the system. As shown in figure 3, rejiband® wire mesh cable tray and its accessories neither collapsed nor were they detached from the supports, ensuring enough structural resistance within the system. Figure 2: Assembly Before Test rejiband® Figure 3: Assembly After Test Conclusions The wire mesh cable tray exceeded the fire resistance test, qualifying for the highest level of resistance proposed by this standard, the E90. The tray with cables were tested for 90 minutes at temperatures of 1,000ºC (in accordance with the conditions of DIN 4102-12), maintaining circuit integrity against fire. The combined use of rejiband® wire mesh tray with high safety halogen-free electrical cables improves substantially the safety of the installation. Since both components provide a self extinguishing system, which does not produce toxic, corrosive or opaque fumes (more typical for polymeric & halogen materials), this allows a period of time long enough for evacuation and emergency works. Investing in safety equipment and systems with high fire resistance must be accompanied by a safe installation that ensures their correct functioning in the most critical situations. 123 PEMSA-219-109 AL FINAL-REV- 27/11/09 11:51 Página 16 Fire test in the tunnels of El Padrún. Asturias-Spain Test objectives In the tests at the El Padrún tunnels, it was especially taken into account that a fire might occur with the tunnel in service (see bibliography). It was deemed appropriate to perform a fire test in a real environment, in the tunnel itself. Even though this kind of testing could be performed in specialised laboratories, the extrapolation to a real scale could be complicated, and, of course, would have made it difficult to attain some of the most important objectives, which can be summarised as follows: - To maintain direct contact with the Civil Protection and Fire Fighting services that would have to intervene in the event of a fire. - To test materials that have been used traditionally in other tunnels. Fire test area, with a waterproofing layer and two cable tray models installed. - To study the movement of smoke in a tunnel fire, to measure the temperatures reached and to study the composition of the gases emitted. - To allow the fire to develop up to the maximum threshold and then have it extinguished by the Fire Department. Materials tested and measurements taken Cable Trays: Cable trays were fastened to the walls of the tunnel to house the energy cables (lighting, ventilation, communications, etc.). Two kinds of trays were tested: a PVC tray and a metal tray (Rejiband). Chemical Analysis of the Combustion: Possible products from the combustion. Toxic gases: - Carbon monoxide: Produced by the incomplete combustion of carbon, caused by combustion with an oxygen deficit. Highly toxic gas, which, added to the fact that it is colourless and odourless, is very dangerous. - Lack of oxygen: Produced by the needs of the combustion itself. In air, the concentration of oxygen is 21% by volume (nitrogen, 78%; oxygen, 21%; carbon dioxide, 0.035%, etc.). When the oxygen level falls to 12%, headaches and fatigue appear, and if it falls to 6%, death occurs after about 5 to 8 minutes. Tunnel in flames. 124 PEMSA-219-109 AL FINAL-REV- 27/11/09 11:51 Página 17 Fire test in the tunnels of El Padrún. Asturias-Spain - Other gases: From the combustion of the various materials used, the following can be produced: Carbon dioxide, CO2. Hydrochloric acid, CIH. Phosgene, CI2CO. Hydrocyanic acid, CNH: Smoke: - Smoke is produced as a mixture of gases, droplets of liquids and solid particles that are given off in combustion and transported by air. - Even though the previously stated gases are more worrisome from the point of view of their toxicity, in a fire, smoke creates panic, and linked with a reduction in visibility, this almost always results in more victims than the fire itself. Results and conclusions Temperatures reached The maximum temperatures, in the section where the vehicles were set on fire, varied between 40º and 190º C, recorded by the probe at the keystone (straight above the fire). On the side faces of the same section, the maximum temperatures reached was 75º C. In the area behind the fire, in the direction of the gas motion impelled by the ventilation, the maximum temperatures measured were 60º at the keystone and 37º on the side faces. Smoke and gases produced The test clearly showed the fundamental importance of smoke production in a tunnel fire, given that it cancels out visibility in a very short period of time over long sections. Frequently, the reactions that may be caused by panic must be added to this difficulty. Behaviour of the tested materials Both the waterproofing layer as well as the PVC cable tray that were tested were rapidly sensitive to the effects of the fire (the metal tray was not affected at all). The PVC cable tray began to undergo a process of deformation due to the effect of heat, and continued to deform (without burning), thereby reaching a point where, if the tray held cables (its real task), the cables would have fallen or they would have held the tray. Final notes Reduction of visibility: After the fire, the area between the damaged vehicle and the smoke outlet filled completely with smoke within a few minutes. The solution to the problems that can occur in a tunnel in service have to be planned for, the material and human resources have to be operational (trained personnel are required), and they must all be backed up by the various entities that could be involved. 125 PEMSA-219-109 AL FINAL-REV- 27/11/09 11:51 Página 18 Product Index by Description Description Adjustable bend Click Adjustable medium duty cantilever RPLUS Angle bracket Angle tray Angle tray fastener Beam clamp hanging assembly Bend 90º Click Bend 90º Click cover Bend cover 90º for Inducanal Bend 90º for Inducanal Bolt cutter Box support for Rejitech Ceiling bracket Ceiling fastener for Rejitech Central hanging plate Central hanging plate 7 Central joiner Clamp Click central suspension Click connector Connector plate Cover Crossover Click Crossover Click cover Channel beam clamp Channel floor boss Channel nut Data outlet Divider plate Double heavy duty pendant drop Earth terminal Fixing support for Rejiband Floor foot Floor foot adhesive Gland bracket Heavy duty cantilever RPLUS Heavy duty channel 41x41 Heavy duty channel 41x21 Heavy duty pendant boss Heavy duty pendant channel Heavy duty pendant drop Horizontal angle hanger Identification label Identification plate Inducanal Inducanal Cover Inside riser Click Inside riser cover Click Joiner Light duty channel 41x21 Light duty channel 41x41 Medium duty cantilever RPLUS 126 Page 72 36-84 106 14-48 48 42-90 74 74 100 100 17 54 40-88-103 54 17-40-103 100 68 106 40-103 22 17-28-72 28-70 76 76 106 106 104 28 28-68 48-96 24-50 26 50 50 28-50 36-84 104 104 48-96 48-96 48-96-103 42-88 28-68 26 98 100 78 78 68-100 104 104 36-84 PEMSA-219-109 AL FINAL-REV- 27/11/09 11:51 Description Mesh channel Mesh Click channel Mini universal bracket Nuts Omega bracket Omega ceiling bracket Omega Click bracket Omega Click ceiling bracket Omega pendant bracket Outside riser Click Outside riser cover Click Part clamp Pemsaband System Pemsaband SX Pemsaband RX Pemsaband LX Protector for ends & edges Reducer Reinforced joint clamp Rejiband Rejiband box support Rejifix Rejitech Riser/Dropper Rod connector M8 Screws Side entry Click Side entry Click cover Side joint-plate Side support 60 Splice plate Stand off bracket Supports & structures Threaded rod Tee Click Tee Click cover Tee plate Universal bracket Universal bracket for Pemsaband Variable ceiling rod bracket Vertical angle hanger Washers Wire end cap Zinc paint spray Página 19 Page 42-90-103 42 32-103 107 34-82-103 46-83-94 34 46-103 46-83-94-103 78 78 17-24 56 60 65 67 70 70 17-22 14-50 26 26-72 14-52-54 70 40-88 107 76 76 22 32-40-106 17-24-106 32-68 102 40-88-100-103 74 74 106 28 72-100 40-88-103 42-88 107 22 24-72 127 PEMSA-219-109 AL FINAL-REV- 27/11/09 11:51 Página 20 Product Index by Reference Number Ref Description Finish Quantity EAN 13 Page 60.21 60.211.100 60.211.200 60.211.300 60.211.400 60.212.060 60.212.100 60.212.150 60.212.200 60.212.300 60.212.400 60.212.500 60.212.600 60.213.200 60.213.300 60.213.400 60.213.500 60.213.600 60.215.020 REJIBAND 35x100 REJIBAND 35x200 REJIBAND 35x300 REJIBAND 35x400 REJIBAND 60x 60 REJIBAND 60x100 REJIBAND 60x150 REJIBAND 60x200 REJIBAND 60x300 REJIBAND 60x400 REJIBAND 60x500 REJIBAND 60x600 REJIBAND 100x200 REJIBAND 100x300 REJIBAND 100x400 REJIBAND 100x500 REJIBAND 100x600 REJITECH 60x100 E.G. E.G. E.G. E.G. E.G. E.G. E.G. E.G. E.G. E.G. E.G. E.G. E.G. E.G. E.G. E.G. E.G. E.G. m m m m m m m m m m m m m m m m m m 24 18 18 12 24 24 24 18 12 6 6 6 6 6 6 6 6 16 8431927012395 8431927012401 8431927012418 8431927015907 8431927012425 8431927012432 8431927012449 8431927012456 8431927012463 8431927012470 8431927012487 8431927012494 8431927012500 8431927012517 8431927012524 8431927012531 8431927012548 8431927012562 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14-54 ANGLE WIRE MESH TRAY REJIBAND 35x100 REJIBAND 35x200 REJIBAND 35x300 REJIBAND 35x400 REJIBAND 60x 60 REJIBAND 60x100 REJIBAND 60x150 REJIBAND 60x200 REJIBAND 60x300 REJIBAND 60x400 REJIBAND 60x500 REJIBAND 60x600 REJIBAND 100x200 REJIBAND 100x300 REJIBAND 100x400 REJIBAND 100x500 REJIBAND 100x600 REJITECH 60x100 BYCRO BYCRO BYCRO BYCRO BYCRO BYCRO BYCRO BYCRO BYCRO BYCRO BYCRO BYCRO BYCRO BYCRO BYCRO BYCRO BYCRO BYCRO BYCRO m m m m m m m m m m m m m m m m m m m 18 24 18 18 12 24 24 24 18 12 6 6 6 6 6 6 6 6 16 8431927006462 8431927006479 8431927006486 8431927006493 8431927015914 8431927006509 8431927006516 8431927006523 8431927006530 8431927006547 8431927006554 8431927006561 8431927006578 8431927006585 8431927006592 8431927006608 8431927006615 8431927006622 8431927006646 14-48 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14-54 ANGLE WIRE MESH TRAY REJIBAND 35x100 REJIBAND 35x200 REJIBAND 35x300 REJIBAND 35x400 REJIBAND 60x 60 REJIBAND 60x100 REJIBAND 60x150 REJIBAND 60x200 REJIBAND 60x300 REJIBAND 60x400 REJIBAND 60x500 REJIBAND 60x600 REJIBAND 100x200 REJIBAND 100x300 REJIBAND 100x400 REJIBAND 100x500 REJIBAND 100x600 H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. m m m m m m m m m m m m m m m m m m 18 24 18 18 12 24 24 24 18 12 6 6 6 6 6 6 6 6 8431927006653 8431927006660 8431927006677 8431927006684 8431927015921 8431927006691 8431927006707 8431927006714 8431927006721 8431927006738 8431927006745 8431927006752 8431927006769 8431927006776 8431927006783 8431927006790 8431927006806 8431927006813 14-48 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 ANGLE WIRE MESH TRAY REJIBAND 35x100 REJIBAND 35x200 REJIBAND 35x300 REJIBAND 35x400 S.S.304 S.S.304 S.S.304 S.S.304 S.S.304 m m m m m 18 24 18 18 12 8431927006820 8431927006837 8431927006844 8431927006851 8431927015938 14-48 14 14 14 14 60.22 60.220.000 60.221.100 60.221.200 60.221.300 60.221.400 60.222.060 60.222.100 60.222.150 60.222.200 60.222.300 60.222.400 60.222.500 60.222.600 60.223.200 60.223.300 60.223.400 60.223.500 60.223.600 60.225.020 60.23 60.230.000 60.231.100 60.231.200 60.231.300 60.231.400 60.232.060 60.232.100 60.232.150 60.232.200 60.232.300 60.232.400 60.232.500 60.232.600 60.233.200 60.233.300 60.233.400 60.233.500 60.233.600 60.25 60.250.000 60.251.100 60.251.200 60.251.300 60.251.400 128 PEMSA-219-109 AL FINAL-REV- Ref 60.252.060 60.252.100 60.252.150 60.252.200 60.252.300 60.252.400 60.252.500 60.252.600 60.253.200 60.253.300 60.253.400 60.253.500 60.253.600 27/11/09 11:51 Página 21 Description Finish Quantity EAN 13 Page REJIBAND 60x 60 REJIBAND 60x100 REJIBAND 60x150 REJIBAND 60x200 REJIBAND 60x300 REJIBAND 60x400 REJIBAND 60x500 REJIBAND 60x600 REJIBAND 100x200 REJIBAND 100x300 REJIBAND 100x400 REJIBAND 100x500 REJIBAND 100x600 S.S.304 S.S.304 S.S.304 S.S.304 S.S.304 S.S.304 S.S.304 S.S.304 S.S.304 S.S.304 S.S.304 S.S.304 S.S.304 m m m m m m m m m m m m m 24 24 24 18 12 6 6 6 6 6 6 6 6 8431927006868 8431927006875 8431927006882 8431927006899 8431927006905 8431927006912 8431927006929 8431927006936 8431927006943 8431927006950 8431927006967 8431927006974 8431927006981 14 14 14 14 14 14 14 14 14 14 14 14 14 ANGLE WIRE MESH TRAY REJIBAND 35x100 REJIBAND 35x200 REJIBAND 35x300 REJIBAND 35x400 REJIBAND 60x 60 REJIBAND 60x100 REJIBAND 60x150 REJIBAND 60x200 REJIBAND 60x300 REJIBAND 60x400 REJIBAND 60x500 REJIBAND 60x600 REJIBAND 100x200 REJIBAND 100x300 REJIBAND 100x400 REJIBAND 100x500 REJIBAND 100x600 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 m m m m m m m m m m m m m m m m m m 18 24 18 18 12 24 24 24 18 12 6 6 6 6 6 6 6 6 8431927108458 8431927018465 8431927018472 8431927018489 8431927018496 8431927018502 8431927014726 8431927014733 8431927014740 8431927014757 8431927014764 8431927014771 8431927014788 8431927018519 8431927018526 8431927018533 8431927018540 8431927018557 14-48 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 SIDE SUPPORT 60 E.G. u 25 8431927012579 32-40 SIDE SUPPORT 60 OMEGA BRACKET 100 OMEGA BRACKET 150 OMEGA BRACKET 200 SUPPORT/PENDANT OMEGA BRACKET 300 SUPPORT/PENDANT OMEGA BRACKET 400 OMEGA PENDANT BRACKET 500 OMEGA PENDANT BRACKET 600 OMEGA CEILING BRACKET 100 OMEGA CEILING BRACKET 150 OMEGA CEILING BRACKET 200 OMEGA CEILING BRACKET 300 OMEGA CEILING BRACKET 400 OMEGA CLICK BRACKET 100 OMEGA CLICK BRACKET 150 OMEGA CLICK BRACKET 200 OMEGA CLICK BRACKET 300 OMEGA CLICK BRACKET 400 MED DUTY CANTILEVER RPLUS 100 MED DUTY CANTILEVER RPLUS 150 MED DUTY CANTILEVER RPLUS 200 MED DUTY CANTILEVER RPLUS 300 MED DUTY CANTILEVER RPLUS 400 MED DUTY CANTILEVER RPLUS 500 MED DUTY CANTILEVER RPLUS 600 MINI UNIVERSAL BRACKET UNIVERSAL BRACKET REJIBAND OMEGA CLICK CEILING BRACKET 100 OMEGA CLICK CEILING BRACKET 150 OMEGA CLICK CEILING BRACKET 200 OMEGA CLICK CEILING BRACKET 300 OMEGA CLICK CEILING BRACKET 400 E.B. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u 25 5 5 5 5 5 5 5 4 4 4 4 4 5 5 5 5 5 4 4 4 4 4 4 4 10 10 4 4 4 4 4 8431927006998 32-40 8431927017543 34-82 8431927017550 34-82 8431927017567 34-82 8431927017574 34-46-82-83-94 8431927017581 34-46-82-83-94 8431927017598 46-83-94 8431927017604 46-83-94 8431927017611 46-83-94 8431927017628 46-83-94 8431927017635 46-83-94 8431927017642 46-83-94 8431927017659 46-83-94 8431927017666 34 8431927017673 34 8431927017680 34 8431927017697 34 8431927017703 34 8431927039811 36-84 8431927039828 36-84 8431927039835 36-84 8431927039842 36-84 8431927039859 36-84 8431927039866 36-84 8431927039873 36-84 8431927007186 32 8431927007193 28 8431927017710 46 8431927017727 46 8431927017734 46 8431927017741 46 8431927017758 46 H.D.G. H.D.G. H.D.G. u u u 25 5 5 8431927007247 8431927017765 8431927017772 60.26 60.260.000 60.261.100 60.261.200 60.261.300 60.261.400 60.262.060 60.262.100 60.262.150 60.262.200 60.262.300 60.262.400 60.262.500 60.262.600 60.263.200 60.263.300 60.263.400 60.263.500 60.263.600 62.01 62.011.060 62.02 62.021.060 62.021.103 62.021.153 62.021.203 62.021.303 62.021.403 62.021.503 62.021.603 62.022.103 62.022.153 62.022.203 62.022.303 62.022.403 62.023.103 62.023.153 62.023.203 62.023.303 62.023.403 62.025.103 62.025.153 62.025.203 62.025.303 62.025.403 62.025.503 62.025.603 62.026.010 62.026.011 62.029.103 62.029.153 62.029.203 62.029.303 62.029.403 62.03 62.031.060 62.031.103 62.031.153 SIDE SUPPORT 60 OMEGA BRACKET 100 OMEGA BRACKET 150 32-40 34-82 34-82 129 PEMSA-219-109 AL FINAL-REV- Ref 62.031.203 62.031.303 62.031.403 62.031.503 62.031.603 62.032.103 62.032.153 62.032.203 62.032.303 62.032.403 62.033.103 62.033.153 62.033.203 62.033.303 62.033.403 62.035.103 62.035.153 62.035.203 62.035.303 62.035.403 62.035.503 62.035.603 62.036.010 62.036.011 62.037.103 62.037.153 62.037.203 62.037.303 62.037.403 62.037.503 62.037.603 62.039.103 62.039.153 62.039.203 62.039.303 62.039.403 27/11/09 11:51 Página 22 Description Finish Quantity EAN 13 Page OMEGA BRACKET 200 SUPPORT/PENDANT OMEGA BRACKET 300 SUPPORT/PENDANT OMEGA BRACKET 400 OMEGA PENDANT BRACKET 500 OMEGA PENDANT BRACKET 600 OMEGA CEILING BRACKET 100 OMEGA CEILING BRACKET 150 OMEGA CEILING BRACKET 200 OMEGA CEILING BRACKET 300 OMEGA CEILING BRACKET 400 OMEGA CLICK BRACKET 100 OMEGA CLICK BRACKET 150 OMEGA CLICK BRACKET 200 OMEGA CLICK BRACKET 300 OMEGA CLICK BRACKET 400 MED DUTY CANTILEVER RPLUS 100 MED DUTY CANTILEVER RPLUS 150 MED DUTY CANTILEVER RPLUS 200 MED DUTY CANTILEVER RPLUS 300 MED DUTY CANTILEVER RPLUS 400 MED DUTY CANTILEVER RPLUS 500 MED DUTY CANTILEVER RPLUS 600 MINI UNIVERSAL BRACKET UNIVERSAL BRACKET REJIBAND ADJUST HEAVY DUTY CANTILEVER RPLUS 100 ADJUST HEAVY DUTY CANTILEVER RPLUS 150 ADJUST HEAVY DUTY CANTILEVER RPLUS 200 ADJUST HEAVY DUTY CANTILEVER RPLUS 300 ADJUST HEAVY DUTY CANTILEVER RPLUS 400 ADJUST HEAVY DUTY CANTILEVER RPLUS 500 ADJUST HEAVY DUTY CANTILEVER RPLUS 600 OMEGA CLICK CEILING BRACKET 100 OMEGA CLICK CEILING BRACKET 150 OMEGA CLICK CEILING BRACKET 200 OMEGA CLICK CEILING BRACKET 300 OMEGA CLICK CEILING BRACKET 400 H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u 5 5 5 5 5 4 4 4 4 4 5 5 5 5 5 4 4 4 4 4 4 4 10 10 4 4 4 4 4 4 4 4 4 4 4 4 8431927017789 34-82 8431927017796 34-46-82-83-94 8431927017802 34-46-82-83-94 8431927017819 46-83-94 8431927017826 46-83-94 8431927017833 46-83-94 8431927017840 46-83-94 8431927017857 46-83-94 8431927017864 46-83-94 8431927017871 46-83-94 8431927017888 34 8431927017895 34 8431927017901 34 8431927017918 34 8431927017925 34 8431927039880 36-84 8431927039897 36-84 8431927039903 36-84 8431927039910 36-84 8431927039927 36-84 8431927039934 36-84 8431927039941 36-84 8431927007667 32 8431927007674 28 8431927039958 36-84 8431927039965 36-84 8431927039972 36-84 8431927039989 36-84 8431927039996 36-84 8431927040008 36-84 8431927040015 36-84 8431927017932 46 8431927017949 46 8431927017956 46 8431927017963 46 8431927017970 46 SIDE SUPPORT 60 OMEGA BRACKET 100 OMEGA BRACKET 150 OMEGA BRACKET 200 SUPPORT/PENDANT OMEGA BRACKET 300 SUPPORT/PENDANT OMEGA BRACKET 400 OMEGA PENDANT BRACKET 500 OMEGA PENDANT BRACKET 600 OMEGA CEILING BRACKET 100 OMEGA CEILING BRACKET 150 OMEGA CEILING BRACKET 200 OMEGA CEILING BRACKET 300 OMEGA CEILING BRACKET 400 MED DUTY CANTILEVER RPLUS 100 MED DUTY CANTILEVER RPLUS 150 MED DUTY CANTILEVER RPLUS 200 MED DUTY CANTILEVER RPLUS 300 MED DUTY CANTILEVER RPLUS 400 MED DUTY CANTILEVER RPLUS 500 MED DUTY CANTILEVER RPLUS 600 MINI UNIVERSAL BRACKET UNIVERSAL BRACKET REJIBAND S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 u u u u u u u u u u u u u u u u u u u u u u 25 5 5 5 5 5 5 5 4 4 4 4 4 4 4 4 4 4 4 4 10 10 8431927018564 8431927018571 8431927018588 8431927018595 8431927018601 8431927018618 8431927018625 8431927018632 8431927018649 8431927018656 8431927018663 8431927018670 8431927018687 8431927040022 8431927040039 8431927040046 8431927040053 8431927040060 8431927040077 8431927040084 8431927018762 8431927018779 32-40 34 34 34 34-46 34-46 46 46 46 46 46 46 46 36-84 36-84 36-84 36-84 36-84 36-84 36-84 32 28 MESH CLICK CHANNEL 200 MESH CLICK CHANNEL 300 MESH CLICK CHANNEL 400 MESH CLICK CHANNEL 500 MESH CLICK CHANNEL 600 MESH CHANNEL 200 MESH CHANNEL 300 MESH CHANNEL 400 MESH CHANNEL 500 MESH CHANNEL 600 P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. u u u u u u u u u u 10 10 10 10 10 10 10 10 10 10 8431927018106 8431927018113 8431927018120 8431927018137 8431927018144 8431927018151 8431927018168 8431927018175 8431927018182 8431927018199 42 42 42 42 42 42-90 42-90 42-90 42-90 42-90 MESH CLICK CHANNEL 200 MESH CLICK CHANNEL 300 H.D.G. H.D.G. u u 10 10 8431927018205 8431927018212 42 42 62.06 62.061.060 62.061.103 62.061.153 62.061.203 62.061.303 62.061.403 62.061.503 62.061.603 62.062.103 62.062.153 62.062.203 62.062.303 62.062.403 62.065.103 62.065.153 62.065.203 62.065.303 62.065.403 62.065.503 62.065.603 62.066.010 62.066.011 63.02 63.021.203 63.021.303 63.021.403 63.021.503 63.021.603 63.022.203 63.022.303 63.022.403 63.022.503 63.022.603 63.03 63.031.203 63.031.303 130 PEMSA-219-109 AL FINAL-REV- Ref 63.031.403 63.031.503 63.031.603 63.032.203 63.032.303 63.032.403 63.032.503 63.032.603 63.033.303 63.033.403 63.033.503 63.033.603 27/11/09 11:51 Página 23 Description MESH CLICK CHANNEL 400 MESH CLICK CHANNEL 500 MESH CLICK CHANNEL 600 MESH CHANNEL 200 MESH CHANNEL 300 MESH CHANNEL 400 MESH CHANNEL 500 MESH CHANNEL 600 HEAVY DUTY RPLUS CANTILEVER 300 HEAVY DUTY RPLUS CANTILEVER 400 HEAVY DUTY RPLUS CANTILEVER 500 HEAVY DUTY RPLUS CANTILEVER 600 Finish Quantity EAN 13 Page H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. u u u u u u u u u u u u 10 10 10 10 10 10 10 10 4 4 4 4 8431927018229 8431927018236 8431927018243 8431927018250 8431927018267 8431927018274 8431927018281 8431927018298 8431927040091 8431927040107 8431927040114 8431927040121 42 42 42 42-90 42-90 42-90 42-90 42-90 36-84 36-84 36-84 36-84 CLICK CONNECTOR SIDE JOINT PLATE SERRATED HEXAGON FLANGE NUT M 6 PART CLAMP REINFORCED JOINT PLATE CONNECTOR PLATE E.G. E.G. E.G. E.G. E.G. E.G. u u u u u u 25 50 50 50 50 50 8431927012586 8431927012593 8431927008435 8431927012609 8431927012616 8431927012623 22 22 107 17-24 17-22 17-28-72 CLICK CONNECTOR SIDE JOINT PLATE SERRATED HEXAGON FLANGE NUT M 6 PART CLAMP REINFORCED JOINT PLATE CONNECTOR PLATE E.B. E.B. E.B. E.B. E.B. E.B. u u u u u u 25 50 50 50 50 50 8431927008442 8431927008459 8431927008466 8431927008473 8431927008480 8431927008497 22 22 107 17-24 17-22 17-28-72 SIDE JOINT PLATE SERRATED HEXAGON FLANGE NUT M 6 PART CLAMP REINFORCED JOINT PLATE CONNECTOR PLATE H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. u u u u u 50 50 50 50 50 8431927008503 8431927008510 8431927008527 8431927008534 8431927008541 22 107 17-24 17-22 17-28-72 SIDE JOINT PLATE SERRATED HEXAGON FLANGE NUT M6 PART CLAMP REINFORCED JOINT PLATE CONNECTOR PLATE S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 u u u u u 50 50 50 50 50 8431927018786 8431927018793 8431927014818 8431927014825 8431927014832 22 107 17-24 17-22 17-28 CONDUIT GLAND BRACKET CLICK CENTRAL SUSPENSION M 8 CENTRAL HANGING PLATE 9 CEILING FASTENER FOR REJITECH SPLICE PLATE SOULDER SCREW C/DIN603 M 6x12 SOULDER SCREW C/DIN603 M 6x20 THREADED ROD M 6x500 THREADED ROD M 6x1000 CLICK CENTRAL SUSPENSION M 6 CENTRAL HANGING PLATE 7 CLICK CENTRAL SUSPENSION M10 E.G. E.G. E.G. E.G. E.G. E.G. E.G. E.G. E.G. E.G. E.G. E.G. u u u u u u u u u u u u 10 20 20 25 10 100 100 50 50 20 20 20 8431927012630 8431927015945 8431927012654 8431927015839 8431927012685 8431927008602 8431927008619 8431927008626 8431927008633 8431927015952 8431927008664 8431927015969 28 40 17-40 54 17-24 107 107 40-88-100 40-88-100 40 100 40 HEXAGONAL SET SCREW M10x60 WASHER M10 HEXAGONAL NUT M10 DATA OUTLET CONDUIT GLAND BRACKET BOX SUPPORT FOR REJITECH CLICK CENTRAL SUSPENSION M 8 THREADED ROD M 8X500 THREADED ROD M 8x1000 CENTRAL HANGING PLATE 9 BEAM CLAMP HANGING ASS ANGLY TRAY FASTENER CEILING FASTENER FOR REJITECH SPLICE PLATE HEXAGONAL SET SCREW M 6x15 E.G. E.B. E.B. u u u u u u u u u u u u u u u 100 100 100 10 10 10 20 50 50 20 1 10 25 10 100 8431927008718 8431927008725 8431927008732 8431927008749 8431927008756 8431927008763 8431927015976 8431927008770 8431927008787 8431927008794 8431927014672 8431927008824 8431927008831 8431927008848 8431927008855 107 107 107 28 28 54 40 40-88 40-88 17-40 42-90 48 54 17-24 107 64.01 64.010.020 64.010.041 64.010.059 64.010.060 64.010.061 64.010.062 64.02 64.020.030 64.020.041 64.020.059 64.020.060 64.020.061 64.020.062 64.03 64.030.041 64.030.059 64.030.060 64.030.061 64.030.062 64.06 64.060.041 64.060.059 64.060.060 64.060.061 64.060.062 67.01 67.010.040 67.010.043 67.010.046 67.010.052 67.010.053 67.010.099 67.010.100 67.010.140 67.010.141 67.010.143 67.010.144 67.010.243 67.02 67.020.010 67.020.013 67.020.014 67.020.039 67.020.040 67.020.041 67.020.043 67.020.044 67.020.045 67.020.046 67.020.048 67.020.051 67.020.052 67.020.053 67.020.054 E.B. E.B. E.B. E.B. E.B. E.B. E.B. E.B. E.B. E.B. E.G. 131 PEMSA-219-109 AL FINAL-REV- Ref 67.020.055 67.020.058 67.020.059 67.020.061 67.020.062 67.020.063 67.020.065 67.020.067 67.020.077 67.020.079 67.020.083 67.020.084 67.020.086 67.020.092 67.020.095 67.020.098 67.020.100 67.020.140 67.020.141 67.020.143 67.020.145 67.020.146 67.020.243 67.020.610 67.020.611 67.020.612 27/11/09 11:51 Página 24 Description CHANNEL NUT M 6 CHANNEL NUT M10 HEXAGONAL SET SCREW M10x20 WASHER M10 HEXAGONAL NUT M 8 WASHER M 8 SOULDER SCREW C/ALLEN M10x20 ROD CONNECTOR M 8 HEXAGONAL SET SCREW M10x35 HEXAGONAL NUT M10 WASHER M 8 SERRATED WASHER M 8 SERRATED WASHER M10 HEXAGONAL SET SCREW M 8x65 HEXAGONAL NUT M 8 HEXAGONAL CONE POINT SCREW M10x20 SOULDER SCREW C/DIN603 M 6x20 THREADED ROD M 6x 500 THREADED ROD M 6x1000 CLICK CENTRAL SUSPENSION M 6 THREADED ROD M10x1000 CENTRAL HANGING PLATE 11 CLICK CENTRAL SUSPENSION M10 CLICK DIVIDER PLATE 25 CLICK DIVIDER PLATE 50 CLICK DIVIDER PLATE 80 Finish Quantity EAN 13 Page E.G. E.G. E.G. E.G. E.B. E.B. E.G. E.B. E.G. E.G. E.G. PASSIVATED PASSIVATED E.G. E.G. E.B. E.B. E.B. E.B. E.B. E.B. E.B. E.B. P.G. P.G. P.G. u u u u u u u u u u u u u u u u u u u u u u u m m m 100 100 100 100 100 100 50 50 100 100 100 100 100 100 100 10 100 50 50 20 50 20 20 60 48 36 8431927008862 8431927008879 8431927008886 8431927008893 8431927008909 8431927008916 8431927015181 8431927008923 8431927008930 8431927008947 8431927008954 8431927008961 8431927008978 8431927008985 8431927008992 8431927009012 8431927009029 8431927016065 8431927016072 8431927015983 8431927009036 8431927009043 8431927015990 8431927017024 8431927017031 8431927017048 104 104 107 107 107 107 107 40-88 107 107 107 107 107 107 107 107 107 40-88-100 40-88-100 40 40-88 17-40 40 28-68 28-68 28-68 CLICK CENTRAL SUSPENSION M 8 CENTRAL HANGING PLATE 9 SPLICE PLATE HEAVY DUTY CHANNEL HEAVY DUTY CHANNEL HEAVY DUTY CHANNEL HEAVY DUTY CHANNEL CEILING BRACKET VARIABLE CEILING ROD BRACKET CHANNEL FLOR BOSS LIGHT DUTY CHANNEL 41 LIGHT DUTY CHANNEL 21 SOULDER SCREW C/DIN603 M 6x12 SOULDER SCREW C/DIN603 M 6x20 CHANNEL BEAM CLAMP CLICK CENTRAL SUSPENSION M 6 CENTRAL HANGING PLATE 11 ANGLE BRACKET Nº1 ANGLE BRACKET Nº2 TEE PLATE Nº4 TEE PLATE Nº5 SPICE PLATE Nº3 CLAMP 21 CLAMP 41 CLICK CENTRAL SUSPENSION M10 STAND OFF BRACKET 180 STAND OFF BRACKET 350 STAND OFF BRACKET 180 STAND OFF BRACKET 350 CLICK DIVIDER PLATE 25 CLICK DIVIDER PLATE 50 CLICK DIVIDER PLATE 80 HEAVY DUTY PENDANT BOX HEAVY DUTY PENDANT CHANNEL 500 HEAVY DUTY PENDANT CHANNEL 1000 HEAVY DUTY PENDANT DROP 500 HEAVY DUTY PENDANT DROP 1000 DOUBLE HEAVY DUTY PENDANT DROP 500 DOUBLE HEAVY DUTY PENDANT DROP 1000 H.D.G. H.D.G. H.D.G. P.G. P.G. H.D.G. H.D.G. P.G. H.D.G. H.D.G. P.G. P.G. H.D.G. H.D.G. E.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. P.G. P.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. P.G. P.G. P.G. H.D.G. H.D.G. H.D.G. H.D.G. u u u m m m m u u u m m u u u u u u u u u u u u u u u u u m m m u u u u u u u 20 20 10 3 3 3 3 10 1 1 3 3 100 100 1 20 20 1 1 1 1 1 1 1 20 10 10 10 10 60 48 36 1 1 1 1 1 1 1 8431927016003 8431927009050 8431927009067 8431927009074 8431927009081 8431927009098 8431927009104 8431927009128 8431927009135 8431927009142 8431927009159 8431927009166 8431927009210 8431927009227 8431927009234 8431927016010 8431927009241 8431927009258 8431927009265 8431927009272 8431927009289 8431927009296 8431927009302 8431927009319 8431927016027 8431927009326 8431927009333 8431927009340 8431927009357 8431927017055 8431927017062 8431927017079 8431927009401 8431927009418 8431927009425 8431927009432 8431927009449 8431927009456 8431927009463 40 17-40 17-24 104 104 104 104 40-88 40-88 106 104 104 107 107 106 40 17-40 106 106 106 106 106 106 106 40 32-68 32-68 32-68 32-68 28-68 28-68 28-68 48-96 48-96 48-96 48-96 48-96 48-96 48-96 HEXAGONAL NUT M10 CLICK CENTRAL SUSPENSION M 8 THREADED ROD M 8x 500 THREADED ROD M 8x1000 CENTRAL HANGING PLATE 9 SPLICE PLATE HEAVY DUTY CHANNEL HEAVY DUTY CHANNEL S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 u u u u u u u u 100 20 50 50 20 10 3 3 8431927018809 8431927016034 8431927016089 8431927016096 8431927014849 8431927018816 8431927018823 8431927018830 107 40 40 40 17-40 17-24 104 104 67.03 67.030.043 67.030.046 67.030.047 67.030.052 67.030.053 67.030.055 67.030.057 67.030.060 67.030.061 67.030.064 67.030.074 67.030.075 67.030.099 67.030.100 67.030.101 67.030.143 67.030.146 67.030.201 67.030.202 67.030.203 67.030.204 67.030.205 67.030.206 67.030.207 67.030.243 67.030.539 67.030.540 67.030.541 67.030.542 67.030.610 67.030.611 67.030.612 67.030.645 67.030.646 67.030.647 67.030.660 67.030.661 67.030.662 67.030.663 67.06 67.060.014 67.060.043 67.060.044 67.060.045 67.060.046 67.060.053 67.060.055 67.060.057 132 PEMSA-219-109 AL FINAL-REV- Ref 67.060.058 67.060.062 67.060.063 67.060.064 67.060.100 67.060.141 67.060.143 67.060.145 67.060.146 67.060.243 67.060.541 67.060.542 67.060.610 67.060.611 67.060.612 27/11/09 11:51 Página 25 Description CHANNEL NUT M10 HEXAGONAL NUT M 8 WASHER M 8 WASHER M10 SOULDER SCREW C/DIN603 M 6x20 THREADED ROD M 6x1000 CLICK CENTRAL SUSPENSION M 6 THREADED ROD M10x1000 CENTRAL HANGING PLATE 11 CLICK CENTRAL SUSPENSION M10 STAND OFF BRACKET 180 STAND OFF BRACKET 360 CLICK DIVIDER PLATE 25 CLICK DIVIDER PLATE 50 CLICK DIVIDER PLATE 80 Finish S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 Quantity EAN 13 Page u u u u u u u u u u m m m m m 100 100 100 100 100 50 20 50 20 20 10 10 60 48 36 8431927018847 8431927018854 8431927018861 8431927018878 8431927018885 8431927016119 8431927016041 8431927016102 8431927014856 8431927016058 8431927018892 8431927018908 8431927017086 8431927017093 8431927017109 104 107 107 107 107 40 40 40 17-40 40 32 32 28 28 28 u 8431927015860 8431927017017 8431927016126 8431927017529 8431927009647 8431927009654 8431927009661 8431927014719 8431927009678 8431927009685 8431927009692 8431927009708 8431927009715 8431927009722 26 28-68 24-50 26 22 24-72 17 17 50 50 42-88 42-88 42-88 42-88 8431927037046 8431927037053 8431927037060 8431927037077 8431927037084 8431927037091 8431927037107 8431927037114 8431927037121 8431927037138 8431927037145 8431927037152 8431927037169 8431927037176 8431927037183 8431927037190 8431927037206 8431927037213 8431927037220 8431927037237 8431927037244 8431927037251 8431927037268 8431927037275 8431927037282 8431927037299 8431927037305 8431927037312 8431927037329 8431927037336 8431927037343 8431927037350 8431927037367 8431927037374 8431927037381 8431927037398 8431927037404 8431927037411 8431927037428 8431927037435 8431927037442 8431927037459 8431927037466 8431927037473 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 76 76 76 76 76 76 76 76 76 76 76 76 68.00 68.000.010 68.000.020 68.000.032 68.000.040 68.000.049 68.000.052 68.000.058 68.000.059 68.000.060 68.000.065 68.000.721 68.000.722 68.000.731 68.000.732 FIXING SUPPORT FOR REJIBAND IDENTIFICATION LABEL EARTH TERMINAL FOR REJIBAND REJIBAND BOX SUPPORT WIRE END CAP ZINC PAINT SPRAY 400 ml BOLT CUTTER SPECIAL BOLT CUTTER FLOOR FOOT FLOOR FOOT ADHESIVE (A+B) HORIZONTAL ANGLE HANGER 1,50 / 5 HORIZONTAL ANGLE HANGER 5,00 / 9 VERTICAL ANGLE HANGER 1,50 / 5 VERTICAL ANGLE HANGER 4,00 / 10 PASSIVATED PASSIVATED PASSIVATED PASSIVATED u u u u 20 50 20 20 100 1 1 1 100 1 100 100 100 100 P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 u u u u u u 70.02 70.020.110 70.020.115 70.020.120 70.020.130 70.020.210 70.020.215 70.020.220 70.020.230 70.020.240 70.020.250 70.020.260 70.020.320 70.020.330 70.020.340 70.020.350 70.020.360 70.022.110 70.022.115 70.022.120 70.022.130 70.022.210 70.022.215 70.022.220 70.022.230 70.022.240 70.022.250 70.022.260 70.022.320 70.022.330 70.022.340 70.022.350 70.022.360 70.023.110 70.023.115 70.023.120 70.023.130 70.023.210 70.023.215 70.023.220 70.023.230 70.023.240 70.023.250 70.023.260 70.023.320 BEND 90º CLICK 35x100 BEND 90º CLICK 35x150 BEND 90º CLICK 35x200 BEND 90º CLICK 35x300 BEND 90º CLICK 60x100 BEND 90º CLICK 60x150 BEND 90º CLICK 60x200 BEND 90º CLICK 60x300 BEND 90º CLICK 60x400 BEND 90º CLICK 60x500 BEND 90º CLICK 60x600 BEND 90º CLICK 85x200 BEND 90º CLICK 85x300 BEND 90º CLICK 85x400 BEND 90º CLICK 85x500 BEND 90º CLICK 85x600 TEE CLICK 35x100 TEE CLICK 35x150 TEE CLICK 35x200 TEE CLICK 35x300 TEE CLICK 60x100 TEE CLICK 60x150 TEE CLICK 60x200 TEE CLICK 60x300 TEE CLICK 60x400 TEE CLICK 60x500 TEE CLICK 60x600 TEE CLICK 85x200 TEE CLICK 85x300 TEE CLICK 85x400 TEE CLICK 85x500 TEE CLICK 85x600 SIDE ENTRY CLICK 35x100 SIDE ENTRY CLICK 35x150 SIDE ENTRY CLICK 35x200 SIDE ENTRY CLICK 35x300 SIDE ENTRY CLICK 60x100 SIDE ENTRY CLICK 60x150 SIDE ENTRY CLICK 60x200 SIDE ENTRY CLICK 60x300 SIDE ENTRY CLICK 60x400 SIDE ENTRY CLICK 60x500 SIDE ENTRY CLICK 60x600 SIDE ENTRY CLICK 85x200 133 PEMSA-219-109 AL FINAL-REV- Ref 70.023.330 70.023.340 70.023.350 70.023.360 70.024.110 70.024.115 70.024.120 70.024.130 70.024.210 70.024.215 70.024.220 70.024.230 70.024.240 70.024.250 70.024.260 70.024.320 70.024.330 70.024.340 70.024.350 70.024.360 70.025.110 70.025.115 70.025.120 70.025.130 70.025.210 70.025.215 70.025.220 70.025.230 70.025.240 70.025.250 70.025.260 70.025.320 70.025.330 70.025.340 70.025.350 70.025.360 70.026.110 70.026.115 70.026.120 70.026.130 70.026.210 70.026.215 70.026.220 70.026.230 70.026.240 70.026.250 70.026.260 70.026.320 70.026.330 70.026.340 70.026.350 70.026.360 70.028.110 70.028.115 70.028.120 70.028.130 70.028.210 70.028.215 70.028.220 70.028.230 27/11/09 11:51 Página 26 Description SIDE ENTRY CLICK 85x300 SIDE ENTRY CLICK 85x400 SIDE ENTRY CLICK 85x500 SIDE ENTRY CLICK 85x600 CROSSOVER CLICK 35x100 CROSSOVER CLICK 35x150 CROSSOVER CLICK 35x200 CROSSOVER CLICK 35x300 CROSSOVER CLICK 60x100 CROSSOVER CLICK 60x150 CROSSOVER CLICK 60x200 CROSSOVER CLICK 60x300 CROSSOVER CLICK 60x400 CROSSOVER CLICK 60x500 CROSSOVER CLICK 60x600 CROSSOVER CLICK 85x200 CROSSOVER CLICK 85x300 CROSSOVER CLICK 85x400 CROSSOVER CLICK 85x500 CROSSOVER CLICK 85x600 INSIDE RISER CLICK 35x100 INSIDE RISER CLICK 35x150 INSIDE RISER CLICK 35x200 INSIDE RISER CLICK 35x300 INSIDE RISER CLICK 60x100 INSIDE RISER CLICK 60x150 INSIDE RISER CLICK 60x200 INSIDE RISER CLICK 60x300 INSIDE RISER CLICK 60x400 INSIDE RISER CLICK 60x500 INSIDE RISER CLICK 60x600 INSIDE RISER CLICK 85x200 INSIDE RISER CLICK 85x300 INSIDE RISER CLICK 85x400 INSIDE RISER CLICK 85x500 INSIDE RISER CLICK 85x600 OUTSIDE RISER CLICK 35x100 OUTSIDE RISER CLICK 35x150 OUTSIDE RISER CLICK 35x200 OUTSIDE RISER CLICK 35x300 OUTSIDE RISER CLICK 60x100 OUTSIDE RISER CLICK 60x150 OUTSIDE RISER CLICK 60x200 OUTSIDE RISER CLICK 60x300 OUTSIDE RISER CLICK 60x400 OUTSIDE RISER CLICK 60x500 OUTSIDE RISER CLICK 60x600 OUTSIDE RISER CLICK 85x200 OUTSIDE RISER CLICK 85x300 OUTSIDE RISER CLICK 85x400 OUTSIDE RISER CLICK 85x500 OUTSIDE RISER CLICK 85x600 ADJUSTABLE BEND CLICK 35x100 ADJUSTABLE BEND CLICK 35x150 ADJUSTABLE BEND CLICK 35x200 ADJUSTABLE BEND CLICK 35x300 ADJUSTABLE BEND CLICK 60x100 ADJUSTABLE BEND CLICK 60x150 ADJUSTABLE BEND CLICK 60x200 ADJUSTABLE BEND CLICK 60x300 Finish Quantity EAN 13 Page P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 8431927037480 8431927037497 8431927037503 8431927037510 8431927037527 8431927037534 8431927037541 8431927037558 8431927037565 8431927037572 8431927037589 8431927037596 8431927037602 8431927037619 8431927037626 8431927037633 8431927037640 8431927037657 8431927037664 8431927037671 8431927037688 8431927037695 8431927037701 8431927037718 8431927037725 8431927037732 8431927037749 8431927037756 8431927037763 8431927037770 8431927037787 8431927037794 8431927037800 8431927037817 8431927037824 8431927037831 8431927037848 8431927037855 8431927037862 8431927037879 8431927037886 8431927037893 8431927037909 8431927037916 8431927037923 8431927037930 8431927037947 8431927037954 8431927037961 8431927037978 8431927037985 8431927037992 8431927043832 8431927043849 8431927043856 8431927043863 8431927043870 8431927043887 8431927043894 8431927043900 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 72 72 72 72 72 72 72 72 H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. u u u u u u u u u u u u u u u u 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 8431927038005 8431927038012 8431927038029 8431927038036 8431927038043 8431927038050 8431927038067 8431927038074 8431927038081 8431927038098 8431927038104 8431927038111 8431927038128 8431927038135 8431927038142 8431927038159 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 70.03 70.030.110 70.030.115 70.030.120 70.030.130 70.030.210 70.030.215 70.030.220 70.030.230 70.030.240 70.030.250 70.030.260 70.030.320 70.030.330 70.030.340 70.030.350 70.030.360 134 90º BEND CLICK 35x100 90º BEND CLICK 35x150 90º BEND CLICK 35x200 90º BEND CLICK 35x300 90º BEND CLICK 60x300 90º BEND CLICK 60x150 90º BEND CLICK 60x200 90º BEND CLICK 60x300 90º BEND CLICK 60x400 90º BEND CLICK 60x500 90º BEND CLICK 60x600 90º BEND CLICK 85x200 90º BEND CLICK 85x300 90º BEND CLICK 85x400 90º BEND CLICK 85x500 90º BEND CLICK 85x600 PEMSA-219-109 AL FINAL-REV- Ref 70.032.110 70.032.115 70.032.120 70.032.130 70.032.210 70.032.215 70.032.220 70.032.230 70.032.240 70.032.250 70.032.260 70.032.320 70.032.330 70.032.340 70.032.350 70.032.360 70.033.110 70.033.115 70.033.120 70.033.130 70.033.210 70.033.215 70.033.220 70.033.230 70.033.240 70.033.250 70.033.260 70.033.320 70.033.330 70.033.340 70.033.350 70.033.360 70.034.110 70.034.115 70.034.120 70.034.130 70.034.210 70.034.215 70.034.220 70.034.230 70.034.240 70.034.250 70.034.260 70.034.320 70.034.330 70.034.340 70.034.350 70.034.360 70.035.110 70.035.115 70.035.120 70.035.130 70.035.210 70.035.215 70.035.220 70.035.230 70.035.240 70.035.250 70.035.260 70.035.320 70.035.330 70.035.340 70.035.350 70.035.360 70.036.110 70.036.115 70.036.120 70.036.130 70.036.210 70.036.215 70.036.220 70.036.230 70.036.240 70.036.250 70.036.260 70.036.320 70.036.330 70.036.340 70.036.350 27/11/09 11:51 Página 27 Description TEE CLICK 35x100 TEE CLICK 35x150 TEE CLICK 35x200 TEE CLICK 35x300 TEE CLICK 60x100 TEE CLICK 60x150 TEE CLICK 60x200 TEE CLICK 60x300 TEE CLICK 60x400 TEE CLICK 60x500 TEE CLICK 60x600 TEE CLICK 85x200 TEE CLICK 85x300 TEE CLICK 85x400 TEE CLICK 85x500 TEE CLICK 85x600 SIDE ENTRYCLICK 35x100 SIDE ENTRYCLICK 35x150 SIDE ENTRYCLICK 35x200 SIDE ENTRYCLICK 35x300 SIDE ENTRYCLICK 60x100 SIDE ENTRYCLICK 60x150 SIDE ENTRYCLICK 60x200 SIDE ENTRYCLICK 60x300 SIDE ENTRYCLICK 60x400 SIDE ENTRYCLICK 60x500 SIDE ENTRYCLICK 60x600 SIDE ENTRYCLICK 85x200 SIDE ENTRYCLICK 85x300 SIDE ENTRYCLICK 85x400 SIDE ENTRYCLICK 85x500 SIDE ENTRYCLICK 85x600 CROSSOVER CLICK 35x100 CROSSOVER CLICK 35x150 CROSSOVER CLICK 35x200 CROSSOVER CLICK 35x300 CROSSOVER CLICK 60x100 CROSSOVER CLICK 60x150 CROSSOVER CLICK 60x200 CROSSOVER CLICK 60x300 CROSSOVER CLICK 60x400 CROSSOVER CLICK 60x500 CROSSOVER CLICK 60x600 CROSSOVER CLICK 85x200 CROSSOVER CLICK 85x300 CROSSOVER CLICK 85x400 CROSSOVER CLICK 85x500 CROSSOVER CLICK 85x600 INSIDE RISER CLICK 35x100 INSIDE RISER CLICK 35x150 INSIDE RISER CLICK 35x200 INSIDE RISER CLICK 35x300 INSIDE RISER CLICK 60x100 INSIDE RISER CLICK 60x150 INSIDE RISER CLICK 60x200 INSIDE RISER CLICK 60x300 INSIDE RISER CLICK 60x400 INSIDE RISER CLICK 60x500 INSIDE RISER CLICK 60x600 INSIDE RISER CLICK 85x200 INSIDE RISER CLICK 85x300 INSIDE RISER CLICK 85x400 INSIDE RISER CLICK 85x500 INSIDE RISER CLICK 85x600 OUTSIDE RISER CLICK 35x100 OUTSIDE RISER CLICK 35x150 OUTSIDE RISER CLICK 35x200 OUTSIDE RISER CLICK 35x300 OUTSIDE RISER CLICK 60x100 OUTSIDE RISER CLICK 60x150 OUTSIDE RISER CLICK 60x200 OUTSIDE RISER CLICK 60x300 OUTSIDE RISER CLICK 60x400 OUTSIDE RISER CLICK 60x500 OUTSIDE RISER CLICK 60x600 OUTSIDE RISER CLICK 85x200 OUTSIDE RISER CLICK 85x300 OUTSIDE RISER CLICK 85x400 OUTSIDE RISER CLICK 85x500 Finish H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. Quantity u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 EAN 13 8431927038166 8431927038173 8431927038180 8431927038197 8431927038203 8431927038210 8431927038227 8431927038234 8431927038241 8431927038258 8431927038265 8431927038272 8431927038289 8431927038296 8431927038302 8431927038319 8431927038326 8431927038333 8431927038340 8431927038357 8431927038364 8431927038371 8431927038388 8431927038395 8431927038401 8431927038418 8431927038425 8431927038432 8431927038449 8431927038456 8431927038463 8431927038470 8431927038487 8431927038494 8431927038500 8431927038517 8431927038524 8431927038531 8431927038548 8431927038555 8431927038562 8431927038579 8431927038586 8431927038593 8431927038609 8431927038616 8431927038623 8431927038630 8431927038647 8431927038654 8431927038661 8431927038678 8431927038685 8431927038692 8431927038708 8431927038715 8431927038722 8431927038739 8431927038746 8431927038753 8431927038760 8431927038777 8431927038784 8431927038791 8431927038807 8431927038814 8431927038821 8431927038838 8431927038845 8431927038852 8431927038869 8431927038876 8431927038883 8431927038890 8431927038906 8431927038913 8431927038920 8431927038937 8431927038944 Page 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 135 PEMSA-219-109 AL FINAL-REV- Ref 70.036.360 70.038.110 70.038.115 70.038.120 70.038.130 70.038.210 70.038.215 70.038.220 70.038.230 27/11/09 11:51 Página 28 Description OUTSIDE RISER CLICK 85x600 ADJUSTABLE BEND CLICK 35x100 ADJUSTABLE BEND CLICK 35x150 ADJUSTABLE BEND CLICK 35x200 ADJUSTABLE BEND CLICK 35x300 ADJUSTABLE BEND CLICK 60x100 ADJUSTABLE BEND CLICK 60x150 ADJUSTABLE BEND CLICK 60x200 ADJUSTABLE BEND CLICK 60x300 Finish Quantity EAN 13 Page H.D.G. H.D.G. H.D.G. H.D.G H.D.G H.D.G H.D.G H.D.G H.D.G u u u u u u u u u 1 1 1 1 1 1 1 1 1 8431927038951 8431927043917 8431927043924 8431927043931 8431927043948 8431927043955 8431927043962 8431927043979 8431927043986 78 72 72 72 72 72 72 72 72 UNIVERSAL BRACKET PEMSABAND P.G. u 10 8431927009739 72-100 UNIVERSAL BRACKET PEMSABAND H.D.G. u 10 8431927009746 72-100 10 8431927009753 70 70.42 70.420.911 70.43 70.430.911 71.00 71.000.000 PROTECTOR FOR ENDS & EDGES 71.02 71.020.300 71.020.400 71.020.500 71.020.600 71.021.005 71.021.006 71.021.007 71.022.005 71.022.006 71.022.007 71.022.062 71.023.005 CENTRAL JOINER 300 CENTRAL JOINER 400 CENTRAL JOINER 500 CENTRAL JOINER 600 JOINER 35 RISER/DROPER 35 REDUCER PEMSABAND 35 JOINER 60 RISER/DROPER 60 REDUCER PEMSABAND 60 90º BEND INDUCANAL JOINER 85 P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. u u u u u u u u u u u u 10 10 10 10 50 4 4 50 4 4 1 25 8431927009760 8431927009777 8431927009784 8431927009791 8431927009814 8431927009821 8431927009838 8431927010056 8431927010063 8431927010070 8431927010087 8431927013019 68 68 68 68 68 70 70 68-100 70 70 100 68 CENTRAL JOINER 300 CENTRAL JOINER 400 CENTRAL JOINER 500 CENTRAL JOINER 600 JOINER 35 RISER/DROPER 35 REDUCER PEMSABAND 35 JOINER 60 RISER/DROPER 60 REDUCER PEMSABAND 60 JOINER 85 H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. u u u u u u u u u u u 10 10 10 10 50 4 4 50 4 4 25 8431927010414 8431927010421 8431927010438 8431927010445 8431927010469 8431927010476 8431927010483 8431927010704 8431927010711 8431927010728 8431927013026 68 68 68 68 68 70 70 68 70 70 68 90º BEND COVER INDUCANAL P.G. u 1 8431927011060 100 BEND COVER 90º CLICK 100 BEND COVER 90º CLICK 150 BEND COVER 90º CLICK 200 BEND COVER 90º CLICK 300 BEND COVER 90º CLICK 400 BEND COVER 90º CLICK 500 BEND COVER 90º CLICK 600 COVER 60x3 m COVER 100x3 m COVER 150x3 m COVER 200x3 m COVER 300x3 m COVER 400x3 m COVER 500x3 m COVER 600x3 m TEE COVER CLICK 100 TEE COVER CLICK 150 TEE COVER CLICK 200 TEE COVER CLICK 300 TEE COVER CLICK 400 TEE COVER CLICK 500 TEE COVER CLICK 600 P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. u u u u u u u m m m m m m m m u u u u u u u 1 1 1 1 1 1 1 24 24 12 12 6 6 6 6 1 1 1 1 1 1 1 8431927038968 8431927038982 8431927038975 8431927038999 8431927039002 8431927039019 8431927039026 8431927016133 8431927016140 8431927016157 8431927016164 8431927016171 8431927016188 8431927016195 8431927016201 8431927039033 8431927039040 8431927039057 8431927039064 8431927039071 8431927039088 8431927039095 74 74 74 74 74 74 74 28-70-100 28-70 28-70 28-70 28-70 28-70 28-70 28-70 74 74 74 74 74 74 74 71.03 71.030.300 71.030.400 71.030.500 71.030.600 71.031.005 71.031.006 71.031.007 71.032.005 71.032.006 71.032.007 71.033.005 72.02 72.020.062 73.02 73.020.100 73.020.150 73.020.200 73.020.300 73.020.400 73.020.500 73.020.600 73.021.060 73.021.100 73.021.150 73.021.200 73.021.300 73.021.400 73.021.500 73.021.600 73.022.100 73.022.150 73.022.200 73.022.300 73.022.400 73.022.500 73.022.600 136 PEMSA-219-109 AL FINAL-REV- Ref 73.023.100 73.023.150 73.023.200 73.023.300 73.023.400 73.023.500 73.023.600 73.024.100 73.024.150 73.024.200 73.024.300 73.024.400 73.024.500 73.024.600 73.025.100 73.025.150 73.025.200 73.025.300 73.025.400 73.025.500 73.025.600 73.026.100 73.026.150 73.026.200 73.026.300 73.026.400 73.026.500 73.026.600 27/11/09 11:51 Página 29 Description Finish Quantity EAN 13 Page SIDE ENTRY COVER CLICK 100 SIDE ENTRY COVER CLICK 150 SIDE ENTRY COVER CLICK 200 SIDE ENTRY COVER CLICK 300 SIDE ENTRY COVER CLICK 400 SIDE ENTRY COVER CLICK 500 SIDE ENTRY COVER CLICK 600 CROSSOVER CLICK COVER 100 CROSSOVER CLICK COVER 150 CROSSOVER CLICK COVER 200 CROSSOVER CLICK COVER 300 CROSSOVER CLICK COVER 400 CROSSOVER CLICK COVER 500 CROSSOVER CLICK COVER 600 INSIDE RISER COVER CLICK 100 INSIDE RISER COVER CLICK 150 INSIDE RISER COVER CLICK 200 INSIDE RISER COVER CLICK 300 INSIDE RISER COVER CLICK 400 INSIDE RISER COVER CLICK 500 INSIDE RISER COVER CLICK 600 OUTSIDE RISER COVER CLICK 100 OUTSIDE RISER COVER CLICK 150 OUTSIDE RISER COVER CLICK 200 OUTSIDE RISER COVER CLICK 300 OUTSIDE RISER COVER CLICK 400 OUTSIDE RISER COVER CLICK 500 OUTSIDE RISER COVER CLICK 600 P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. u u u u u u u u u u u u u u u u u u u u u u u u u u u u 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 8431927039101 8431927039118 8431927039125 8431927039132 8431927039149 8431927039156 8431927039163 8431927039170 8431927039187 8431927039194 8431927039200 8431927039217 8431927039224 8431927039231 8431927039248 8431927039255 8431927039262 8431927039279 8431927039286 8431927039293 8431927039309 8431927039316 8431927039323 8431927039330 8431927039347 8431927039354 8431927039361 8431927039378 76 76 76 76 76 76 76 76 76 76 76 76 76 76 78 78 78 78 78 78 78 78 78 78 78 78 78 78 BEND COVER 90º CLICK 100 BEND COVER 90º CLICK 150 BEND COVER 90º CLICK 200 BEND COVER 90º CLICK 300 BEND COVER 90º CLICK 400 BEND COVER 90º CLICK 500 BEND COVER 90º CLICK 600 COVER 60x3 m COVER 100x3 m COVER 150x3 m COVER 200x3 m COVER 300x3 m COVER 400x3 m COVER 500x3 m COVER 600x3 m TEE COVER CLICK 100 TEE COVER CLICK 150 TEE COVER CLICK 200 TEE COVER CLICK 300 TEE COVER CLICK 400 TEE COVER CLICK 500 TEE COVER CLICK 600 SIDE ENTRY COVER CLICK 100 SIDE ENTRY COVER CLICK 150 SIDE ENTRY COVER CLICK 200 SIDE ENTRY COVER CLICK 300 SIDE ENTRY COVER CLICK 400 SIDE ENTRY COVER CLICK 500 SIDE ENTRY COVER CLICK 600 CROSSOVER CLICK COVER 100 CROSSOVER CLICK COVER 150 CROSSOVER CLICK COVER 200 CROSSOVER CLICK COVER 300 CROSSOVER CLICK COVER 400 CROSSOVER CLICK COVER 500 CROSSOVER CLICK COVER 600 INSIDE RISER COVER CLICK 100 INSIDE RISER COVER CLICK 150 INSIDE RISER COVER CLICK 200 INSIDE RISER COVER CLICK 300 INSIDE RISER COVER CLICK 400 INSIDE RISER COVER CLICK 500 INSIDE RISER COVER CLICK 600 OUTSIDE RISER COVER CLICK 100 OUTSIDE RISER COVER CLICK 150 OUTSIDE RISER COVER CLICK 200 OUTSIDE RISER COVER CLICK 300 OUTSIDE RISER COVER CLICK 400 H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. u u u u u u u m m m m m m m m u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u 1 1 1 1 1 1 1 24 24 12 12 6 6 6 6 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 8431927039385 8431927039392 8431927039408 8431927039415 8431927039422 8431927039439 8431927039446 8431927016218 8431927016225 8431927016232 8431927016249 8431927016256 8431927016263 8431927016270 8431927016287 8431927039453 8431927039460 8431927039477 8431927039484 8431927039491 8431927039507 8431927039514 8431927039521 8431927039538 8431927039545 8431927039552 8431927039569 8431927039576 8431927039583 8431927039590 8431927039606 8431927039613 8431927039620 8431927039637 8431927039644 8431927039651 8431927039668 8431927039675 8431927039682 8431927039699 8431927039705 8431927039712 8431927039729 8431927039736 8431927039743 8431927039750 8431927039767 8431927039774 74 74 74 74 74 74 74 28-70 28-70 28-70 28-70 28-70 28-70 28-70 28-70 74 74 74 74 74 74 74 76 76 76 76 76 76 76 76 76 76 76 76 76 76 78 78 78 78 78 78 78 78 78 78 78 78 73.03 73.030.100 73.030.150 73.030.200 73.030.300 73.030.400 73.030.500 73.030.600 73.031.060 73.031.100 73.031.150 73.031.200 73.031.300 73.031.400 73.031.500 73.031.600 73.032.100 73.032.150 73.032.200 73.032.300 73.032.400 73.032.500 73.032.600 73.033.100 73.033.150 73.033.200 73.033.300 73.033.400 73.033.500 73.033.600 73.034.100 73.034.150 73.034.200 73.034.300 73.034.400 73.034.500 73.034.600 73.035.100 73.035.150 73.035.200 73.035.300 73.035.400 73.035.500 73.035.600 73.036.100 73.036.150 73.036.200 73.036.300 73.036.400 137 PEMSA-219-109 AL FINAL-REV- Ref 73.036.500 73.036.600 27/11/09 11:51 Página 30 Description Finish Quantity EAN 13 Page OUTSIDE RISER COVER CLICK 500 OUTSIDE RISER COVER CLICK 600 H.D.G. H.D.G. u u 1 1 8431927039781 8431927039798 78 78 COVER 60x3 m COVER 100x3 m COVER 150x3 m COVER 200x3 m COVER 300x3 m COVER 400x3 m COVER 500x3 m COVER 600x3 m S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 S.S.316 m m m m m m m m 24 24 12 12 6 6 6 6 8431927016294 8431927016300 8431927016317 8431927016324 8431927016331 8431927016348 8431927016355 8431927016362 28 28 28 28 28 28 28 28 PEMSABAND INDUCANAL P.G. m 24 8431927011862 99 PEMSABAND SX PERFORATED 85x200 PEMSABAND SX PERFORATED 85x300 PEMSABAND SX PERFORATED 85x400 PEMSABAND SX PERFORATED 85x500 PEMSABAND SX PERFORATED 85x600 PEMSABAND SX PERFORATED 100x200 PEMSABAND SX PERFORATED 100x300 PEMSABAND SX PERFORATED 100x400 PEMSABAND SX PERFORATED 100x500 P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. m m m m m m m m m 6 6 6 6 6 6 6 6 6 8431927012708 8431927012715 8431927012722 8431927012739 8431927012746 8431927036995 8431927043696 8431927037008 8431927043702 60 60 60 60 60 60 60 60 60 PEMSABAND SX PERFORATED 35x100 PEMSABAND SX PERFORATED 35x150 PEMSABAND SX PERFORATED 35x200 PEMSABAND SX PERFORATED 35x300 PEMSABAND SX PERFORATED 35x400 PEMSABAND SX PERFORATED 35x500 PEMSABAND SX PERFORATED 35x600 PEMSABAND SX PERFORATED 60x100 PEMSABAND SX PERFORATED 60x150 PEMSABAND SX PERFORATED 60x200 PEMSABAND SX PERFORATED 60x300 PEMSABAND SX PERFORATED 60x400 PEMSABAND SX PERFORATED 60x500 PEMSABAND SX PERFORATED 60x600 PEMSABAND SX PERFORATED 85x200 PEMSABAND SX PERFORATED 85x300 PEMSABAND SX PERFORATED 85x400 PEMSABAND SX PERFORATED 85x500 PEMSABAND SX PERFORATED 85x600 PEMSABAND SX PERFORATED 100x200 PEMSABAND SX PERFORATED 100x300 PEMSABAND SX PERFORATED 100x400 PEMSABAND SX PERFORATED 100x500 H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. m m m m m m m m m m m m m m m m m m m m m m m 24 12 12 12 6 6 6 24 12 12 6 6 6 6 6 6 6 6 6 6 6 6 6 8431927011985 8431927011992 8431927012005 8431927012012 8431927041555 8431927041562 8431927041579 8431927012029 8431927012036 8431927012043 8431927012050 8431927012067 8431927012074 8431927012081 8431927012753 8431927012760 8431927012777 8431927012784 8431927012791 8431927043719 8431927043726 8431927043733 8431927043740 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 PEMSABAND SX SOLID 85x200 PEMSABAND SX SOLID 85x300 PEMSABAND SX SOLID 85x400 PEMSABAND SX SOLID 85x500 PEMSABAND SX SOLID 85x600 PEMSABAND SX SOLID 100x200 PEMSABAND SX SOLID 100x300 PEMSABAND SX SOLID 100x400 PEMSABAND SX SOLID 100x500 P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. m m m m m m m m m 6 6 6 6 6 6 6 6 6 8431927012807 8431927012814 8431927012821 8431927012838 8431927012845 8431927043757 8431927043764 8431927043771 8431927043788 63 63 63 63 63 63 63 63 63 PEMSABAND SX SOLID 35x100 PEMSABAND SX SOLID 35x150 PEMSABAND SX SOLID 35x200 PEMSABAND SX SOLID 35x300 PEMSABAND SX SOLID 35x400 PEMSABAND SX SOLID 35x500 PEMSABAND SX SOLID 35x600 PEMSABAND SX SOLID 60x100 H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. m m m m m m m m 24 12 12 12 6 6 6 24 8431927012852 8431927012869 8431927012876 8431927012883 8431927041586 8431927041593 8431927041609 8431927012890 64 64 64 64 64 64 64 64 73.06 73.061.060 73.061.100 73.061.150 73.061.200 73.061.300 73.061.400 73.061.500 73.061.600 75.12 75.122.060 75.22 75.223.200 75.223.300 75.223.400 75.223.500 75.223.600 75.224.200 75.224.300 75.224.400 75.224.500 75.23 75.231.100 75.231.150 75.231.200 75.231.300 75.231.400 75.231.500 75.231.600 75.232.100 75.232.150 75.232.200 75.232.300 75.232.400 75.232.500 75.232.600 75.233.200 75.233.300 75.233.400 75.233.500 75.233.600 75.234.200 75.234.300 75.234.400 75.234.500 75.42 75.423.200 75.423.300 75.423.400 75.423.500 75.423.600 75.424.200 75.424.300 75.424.400 75.424.500 75.43 75.431.100 75.431.150 75.431.200 75.431.300 75.431.400 75.431.500 75.431.600 75.432.100 138 PEMSA-219-109 AL FINAL-REV- Ref 75.432.150 75.432.200 75.432.300 75.432.400 75.432.500 75.432.600 75.433.200 75.433.300 75.433.400 75.433.500 75.433.600 75.434.200 75.434.300 75.434.400 75.434.500 27/11/09 11:51 Página 31 Description PEMSABAND SX SOLID 60x150 PEMSABAND SX SOLID 60x200 PEMSABAND SX SOLID 60x300 PEMSABAND SX SOLID 60x400 PEMSABAND SX SOLID 60x500 PEMSABAND SX SOLID 60x600 PEMSABAND SX SOLID 85x200 PEMSABAND SX SOLID 85x300 PEMSABAND SX SOLID 85x400 PEMSABAND SX SOLID 85x500 PEMSABAND SX SOLID 85x600 PEMSABAND SX SOLID 100x200 PEMSABAND SX SOLID 100x300 PEMSABAND SX SOLID 100x400 PEMSABAND SX SOLID 100x500 Finish Quantity EAN 13 Page H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. m m m m m m m m m m m m m m m 12 12 6 6 6 6 6 6 6 6 6 6 6 6 6 8431927012906 8431927012913 8431927012920 8431927012937 8431927012944 8431927012951 8431927012968 8431927012975 8431927012982 8431927012999 8431927013002 8431927043795 8431927043801 8431927043818 8431927043825 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 PEMSABAND SX CLICK PERFORATED 35x100 PEMSABAND SX CLICK PERFORATED 35x150 PEMSABAND SX CLICK PERFORATED 35x200 PEMSABAND SX CLICK PERFORATED 35x200 PEMSABAND SX CLICK PERFORATED 35x400 PEMSABAND SX CLICK PERFORATED 35x500 PEMSABAND SX CLICK PERFORATED 35x600 PEMSABAND SX CLICK PERFORATED 60x100 PEMSABAND SX CLICK PERFORATED 60x150 PEMSABAND SX CLICK PERFORATED 60x200 PEMSABAND SX CLICK PERFORATED 60x200 PEMSABAND SX CLICK PERFORATED 60x400 PEMSABAND SX CLICK PERFORATED 60x500 PEMSABAND SX CLICK PERFORATED 60x600 P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. m m m m m m m m m m m m m m 24 12 12 12 6 6 6 24 12 12 6 6 6 6 8431927034922 8431927034939 8431927034946 8431927034953 8431927041616 8431927041623 8431927041630 8431927016416 8431927016423 8431927016430 8431927034960 8431927041647 8431927041654 8431927041661 60 60 60 60 60 60 60 60 60 60 60 60 60 60 PEMSABAND SX CLICK SOLID 35x100 PEMSABAND SX CLICK SOLID 35x150 PEMSABAND SX CLICK SOLID 35x200 PEMSABAND SX CLICK SOLID 35x300 PEMSABAND SX CLICK SOLID 35x400 PEMSABAND SX CLICK SOLID 35x500 PEMSABAND SX CLICK SOLID 35x600 PEMSABAND SX CLICK SOLID 60x100 PEMSABAND SX CLICK SOLID 60x150 PEMSABAND SX CLICK SOLID 60x200 PEMSABAND SX CLICK SOLID 60x300 PEMSABAND SX CLICK SOLID 60x400 PEMSABAND SX CLICK SOLID 60x500 PEMSABAND SX CLICK SOLID 60x600 P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. m m m m m m m m m m m m m m 24 12 12 12 6 6 6 24 12 12 6 6 6 6 8431927034977 8431927034984 8431927034991 8431927035004 8431927041678 8431927041685 8431927041692 8431927016737 8431927016744 8431927016751 8431927035011 8431927041708 8431927041715 8431927041722 63 63 63 63 63 63 63 63 63 63 63 63 63 63 PEMSABAND LX CLICK PERFORATED 35x100 PEMSABAND LX CLICK PERFORATED 35x150 PEMSABAND LX CLICK PERFORATED 35x200 PEMSABAND LX CLICK PERFORATED 35x300 PEMSABAND LX CLICK PERFORATED 35x400 PEMSABAND LX CLICK PERFORATED 35x500 PEMSABAND LX CLICK PERFORATED 35x600 PEMSABAND LX CLICK PERFORATED 60x100 PEMSABAND LX CLICK PERFORATED 60x150 PEMSABAND LX CLICK PERFORATED 60x200 PEMSABAND LX CLICK PERFORATED 60x300 PEMSABAND LX CLICK PERFORATED 60x400 PEMSABAND LX CLICK PERFORATED 60x500 PEMSABAND LX CLICK PERFORATED 60x600 P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. m m m m m m m m m m m m m m 840 504 420 252 288 240 138 720 492 360 204 180 156 72 8431927040541 8431927040558 8431927040565 8431927040572 8431927040589 8431927040596 8431927040602 8431927040619 8431927040626 8431927040633 8431927040640 8431927040657 8431927040664 8431927040671 67 67 67 67 67 67 67 67 67 67 67 67 67 67 PEMSABAND RX PERFORATED 60x100 PEMSABAND RX PERFORATED 60x200 PEMSABAND RX PERFORATED 60x300 PEMSABAND RX PERFORATED 60x400 PEMSABAND RX PERFORATED 60x500 PEMSABAND RX PERFORATED 60x600 PEMSABAND RX PERFORATED 85x200 PEMSABAND RX PERFORATED 85x300 PEMSABAND RX PERFORATED 85x400 PEMSABAND RX PERFORATED 85x500 PEMSABAND RX PERFORATED 85x600 PEMSABAND RX PERFORATED 100x200 P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. m m m m m m m m m m m m 24 12 6 6 6 6 6 6 6 6 6 6 TO CONSULT 8431927043023 8431927043030 8431927043047 8431927043054 8431927043061 8431927043078 8431927043085 8431927043092 8431927043108 8431927043115 8431927043122 65 65 65 65 65 65 65 65 65 65 65 65 75.52 75.521.100 75.521.150 75.521.200 75.521.300 75.521.400 75.521.500 75.521.600 75.522.100 75.522.150 75.522.200 75.522.300 75.522.400 75.522.500 75.522.600 75.62 75.621.100 75.621.150 75.621.200 75.621.300 75.621.400 75.621.500 75.621.600 75.622.100 75.622.150 75.622.200 75.622.300 75.622.400 75.622.500 75.622.600 75.82 75.821.100 75.821.150 75.821.200 75.821.300 75.821.400 75.821.500 75.821.600 75.822.100 75.822.150 75.822.200 75.822.300 75.822.400 75.822.500 75.822.600 76.12 76.122.100 76.122.200 76.122.300 76.122.400 76.122.500 76.122.600 76.123.200 76.123.300 76.123.400 76.123.500 76.123.600 76.124.200 139 PEMSA-219-109 AL FINAL-REV- Ref 76.124.300 76.124.400 76.124.500 27/11/09 11:51 Página 32 Description Finish Quantity EAN 13 Page PEMSABAND RX PERFORATED 100x300 PEMSABAND RX PERFORATED 100x400 PEMSABAND RX PERFORATED 100x500 P.G. P.G. P.G. m m m 6 6 6 8431927043139 8431927043146 8431927043153 65 65 65 PEMSABAND RX PERFORATED 60x100 PEMSABAND RX PERFORATED 60x200 PEMSABAND RX PERFORATED 60x300 PEMSABAND RX PERFORATED 60x400 PEMSABAND RX PERFORATED 60x500 PEMSABAND RX PERFORATED 60x600 PEMSABAND RX PERFORATED 85x200 PEMSABAND RX PERFORATED 85x300 PEMSABAND RX PERFORATED 85x400 PEMSABAND RX PERFORATED 85x500 PEMSABAND RX PERFORATED 85x600 PEMSABAND RX PERFORATED 100x200 PEMSABAND RX PERFORATED 100x300 PEMSABAND RX PERFORATED 100x400 PEMSABAND RX PERFORATED 100x500 H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. m m m m m m m m m m m m m m m 24 12 6 6 6 6 6 6 6 6 6 6 6 6 6 TO CONSULT 8431927043160 8431927043177 8431927043184 8431927043191 8431927043207 8431927043214 8431927043221 8431927043238 8431927043245 8431927043252 8431927043269 8431927043276 8431927043283 8431927043290 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 PEMSABAND RX SOLID 60x200 PEMSABAND RX SOLID 60x300 PEMSABAND RX SOLID 60x400 PEMSABAND RX SOLID 60x500 PEMSABAND RX SOLID 60x600 PEMSABAND RX SOLID 100x200 PEMSABAND RX SOLID 100x300 PEMSABAND RX SOLID 100x400 PEMSABAND RX SOLID 100x500 P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. P.G. m m m m m m m m m 6 6 6 6 6 6 6 6 6 8431927043481 8431927043498 8431927043504 8431927043511 8431927043528 8431927043535 8431927043542 8431927043559 8431927043566 66 66 66 66 66 66 66 66 66 PEMSABAND RX SOLID 60x200 PEMSABAND RX SOLID 60x300 PEMSABAND RX SOLID 60x400 PEMSABAND RX SOLID 60x500 PEMSABAND RX SOLID 60x600 PEMSABAND RX SOLID 100x200 PEMSABAND RX SOLID 100x300 PEMSABAND RX SOLID 100x400 PEMSABAND RX SOLID 100x500 H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. H.D.G. m m m m m m m m m 6 6 6 6 6 6 6 6 6 8431927043573 8431927043580 8431927043597 8431927043603 8431927043610 8431927043627 8431927043634 8431927043641 8431927043658 66 66 66 66 66 66 66 66 66 8431927012203 8431927014689 26 26-72 76.13 76.132.100 76.132.200 76.132.300 76.132.400 76.132.500 76.132.600 76.133.200 76.133.300 76.133.400 76.133.500 76.133.600 76.134.200 76.134.300 76.134.400 76.134.500 76.32 76.323.200 76.323.300 76.323.400 76.323.500 76.323.600 76.324.200 76.324.300 76.324.400 76.324.500 76.33 76.333.200 76.333.300 76.333.400 76.333.500 76.333.600 76.334.200 76.334.300 76.334.400 76.334.500 89.01 89.010.000 89.011.000 140 IDENTIFICATION PLATE REJIFIX BLACK u 50 ROLL 1 General Catalogue Origin, development and current position Pemsa was founded in Madrid in 1969, and today it is a company engaged in the manufacture of metal tray and channel systems for the support and management of medium and low voltage electric cables, as well as the manufacture of flexible tubing, connectors, compression glands and accessories. Pemsa heads the ranking of Spanish manufacturers of metal cable trays and is second at the European level as manufacturer of wire mesh cable trays of electrically welded steel. Moreover, Pemsa is one of the top 10 leading European manufacturers. New facilities At the end of 2002, the company inaugurated its new facilities at Alcalá de Henares, (Madrid). The current surface area exceeds 45,000 m2, of which 10,500 m2 consists of building space, including 1500 m2 assigned to offices and administrative departments.The new factory is equipped with the most modern technology available in the world today. This technology also extends to the warehouse and central offices, which include the various commercial and marketing departments, the Technical Office, Production, Quality, Exports, Logistics and Customer Service. The capacity of these new facilities may be doubled in the future. Metal tray and channel system for cod. CYNW. E305934 F o r f u r t h e r i n f o r m a t i o n re g a rd i n g t h e s e c e r t i f i c a t e s p l e a s e c h e c k w i t h i n t h e d o c u m e n t . Catalogue Nº 219 SUBSIDIARIES: PEMSA UK: Unit 2. Hunslet Trading Estate Severn Road, LEEDS LS10 1BL Tel.: 0113 277 9090 Fax.: 0113 277 5939 sales@pemsa.co.uk Metal tray and channel system for cable support and management PEMSA PORTUGAL: Estrada de Polima. Centro Industrial de Abóboda Edificio Fase 2. 2ºK 2785-543 São Domingos de Rana Tel: +351 21 444 5725 Fax: +351 21 444 5727 pemsa.portugal@pemsa-rejiband.com PEMSA FRANCE: ZI Le clos aux pois. 12 Rue de la Closerie, 91090 LISSES Tél.: 01 60 86 75 65 Telécopie: 01 60 87 11 83 service-client@pemsa.fr www.pemsa.fr HEADQUARTERS: PEMSA SPAIN: Galileo Galilei, 22-24. P.E. La Garena 28806 Alcalá de Henares. Madrid Tel: +34 91 802 34 88 Fax: +34 91 802 33 81 info@pemsa-rejiband.com Cable Management System Metal tray and channel system for cable support and management www.pemsa-rejiband.com cod. CYNW. E305934 F o r f u r t h e r i n f o r m a t i o n re g a rd i n g t h e s e c e r t i f i c a t e s p l e a s e c h e c k w i t h i n t h e d o c u m e n t . Depósito Legal: M-12392-2008 Catalogue Nº 219 E-mail: info@pemsa-rejiband.com General Catalogue
Similar documents
NEW - Aste
Its design prevents the accumulation of dust and dirt. It provides maximum cleanliness and faster and easier handling. The reduction in installation time exceeds 55%, given that it has been designe...
More informationpemsaband® Sheet steel trays - Pemsa Cable Management Systems
(*) T he hot dip galvanized finish is NOT AN ACCURATE AESTHETIC FINISH. It is a very effective corrosion protection. COLOUR DIFFERENCES CAN OCCUR (shades of grey), brightness and surface finish
More information