Langendorf Supply Company, Inc.

Transcription

Langendorf Supply Company, Inc.
Langendorf Supply Company, Inc.
St Louis Office: 4653 Crossroads Industrial Drive • Bridgeton, MO • 63044
Phone: 314-291-4892 Fax: 314-291-7815
Web Page: www.lsco-inc.com • Email: lsco@lsco-inc.com
Toll Free 866-489-4892
www.lindabusa.com
www.lorencook.com
• Spiral Ductwork
• Gasket Self Sealing Fittings
• Grilles
• Drum Louvers
• Exhaust & Supply Fans
• Blowers & Ventilators
• Gravity Vents
• Energy Recovery Units
www.ruskin.com
www.titus-hvac.com
• Control Dampers
• Fire, Smoke and Fire/Smoke Dampers
• Louvers
• Duct Access Doors
• Grilles, Registers and Diffusers
• Terminal Units
• Fan Coil Units
www.ductsox.com
• Fabric Air Dispersion System
www.dsp-monoxivent.com
www.gripple.com
• Dust, Vehicle & Fume Collection Equipment
www.doncoair.com
• Cable Support System for Duct
and Equipment
• Diffusers
• Bar Grilles
• Square to Rounds
www.kees.com
www.ruskinsound.com
• Sound Attenuators
• Transfer Ducts
• Sound Panels
www.plastecvent.com
• Polypropylene Fans & Accessories
www.thermolec.com
• Security Bars & Grilles
• Kitchen Hoods
• Electric Duct Heaters, SCR Control
www.hartandcooley.com
• Grilles, Registers and Diffusers
• Baseboard Grilles
www.qmarkmep.com
www.fantech.net
www.tutco.com
• Electric Duct Heaters
• Electric Heaters, Fans and Air
Circulators
• Orifice damper - Combination Flow
Measuring & Balance
• In-line Centrifugal Duct Fan
www.smcduct.com
• Spin-in Collars
• Airtites (EZ-Taps)
www.ajmfg.com
www.milcorinc.com
www.herculesindustries.com • Access Doors
• High Efficiency Take-Offs
• Stainless Steel Grilles, Registers
• Configurable System Controllers and Diffusers
• Pre-Programmed Package AC
Controllers
• Variable Air Volume Controllers
www.asicontrols.com
www.lc-systems.com
• Air Units
• Kitchen Exhaust Hoods
www.flexibletechnologies.com
• Flex Duct & Accessories
www.sbt.siemens.com
www.spaceray.com
• Infrared Gas Heaters
• Ceramic Heaters
www.dayus.com
• Plastic Grilles and Registers
• Heat/Smoke Vents
• Hatches
• HVAC Variable Frequency Drives
www.seiho.com
• Spot Diffusers
• Round Registers
• Vents
www.veco-ny.com
• Seismic Isolators
www.nordfab.com
www.poweredaire.com
• Air Doors/Curtains - Opt Heat: direct/
indirect heat, indirect gas, electric, steam
and hot water
• Quick-fit Duct Fitting Clamping System
www.thermalcoreinc.com
• Low Temperature Air Diffusers
www.youngregulator.com
www.marsair.com
• Remote Cable Control Devices
* Damper Controls
* Dampers
• Air Doors and Curtains
www.reliablehvac.com
• Grilles, Registers and Diffusers
wwwwww.flaktwoods.com
• Tunnel Fans
• Industrial Blowers
www.markserv.com
www.donaldson.com
• Dust & Fume Collection Equipment
• Duct/Pipe/Equipment Markers
• Valve Tags
• Equipment Name Plates
• Signs
www.rpscurbs.com
• Roof Curbs, Equipment Rails,
Pipe Supports
www.continentalfan.com
• Iris Damper - Flow Measuring &
Balancing Types
• In-line Centrifugal Duct Fans
www.plasticair.com
• Fans & Exhauster (FRP & Polypropylene)
Langendorf Supply Co., Inc.
Web Page: www.lsco-inc.com • Email: lsco@lsco-inc.com
St Louis Office
4653 Crossroads Industrial Dr • Bridgeton, MO • 63044 Phone: 314-291-4892
Toll Free: 866-489-4892
ACCOUNTING
SALES TEAMS
Name
Ext Title
Email
Ken Arnsmeyer
305
karnsmeyer@lsco-inc.com
Name
Ext Title
Email
Susan Schniepp
302
sschniepp@lsco-inc.com
ESTIMATING
WAREHOUSE
Accounting
301
Accounting Assistant
kschniepp@lsco-inc.com
Laura Hufendick
330
Accounting Assistant
lhufendick@lsco-inc.com
Dawn Schmidt
300
Reception
dschmidt@lsco-inc.com
Name
Ext Title
Email
Neil Gray
304
Sales
ngray@lsco-inc.com
Cheryl Meehan
318
Sales
cmeehan@lsco-inc.com
Kim Dickey
327
Sales Assistant /CSR
kdickey@lsco-inc.com
Name
Ext Title
Email
Gary Smith
303
Sales
smittie@lsco-inc.com
Ryan Elley
319
Sales
relley@lsco-inc.com
Krista Arnsmeyer
333
Sales / Tech
kla@lsco-inc.com
Beth Jones
311
Sales Asistant / CSR
bjones@lsco-inc.com
Name
Ext Title
Email
Jim Fahrenhorst
309
Sales
jfahren@lsco-inc.com
Ed Wort
310
Sales
ewort@lsco-inc.om
Becky Wilburn
308
Sales Assistant / CSR
bwilburn@lsco-inc.com
Name
Ext Title
Email
Pat Olwig
313
Sales
polwig@lsco-inc.com
Aaron Schweiss
331
Sales
aschweiss@lsco-inc.com
Tom Finder
306
Sales
tfinder@lsco-inc.com
Sales Asistant / CSR
lhurley@lsco-inc.com
Name
Ext Title
Email
Steve Liescheidt
317
stevel@lsco-inc.com
Name
Ext Title
Email
Doug Miles
328
Estimating
dmiles@lsco-inc.com
Estimating
jcasey@lsco-inc.com
Jeff Casey
NEXTEL ID# 37156
PH# 314-486-5717
Principal
Kristi Schniepp
Lisa Hurley
ENGINEERING
Fax: 314-291-7815
Engineer, PE
Name
Ext Title
Email
Bryan Talley
312
Warehouse
warehouse-stl@lsco-inc.com
Lou Kranung
312
Warehouse
warehouse-stl@lsco-inc.com
Langendorf Supply Co., Inc.
Web Page: www.lsco-inc.com • Email: lsco@lsco-inc.com
Peoria Office
2000 West Pioneer Parkway • Peoria, IL • 61615
Name
Ext Title
Phone: 309-693-0731
Email
Fax: 309-693-0767
Tom Mueller
2
Sales
tmueller@lsco-inc.com
Mike Lalumandier
3
Sales
mlalumandier@lsco-inc.com
Felicia Clingan
1
Inside Sales
fclingan@lsco-inc.com
Indianapolis Office
9208 East 33rd Street • Indianapolis, IN • 46235 Phone: 317-890-9601 Fax: 317-890-9612
Toll Free: 866-338-9601
Name
Ext Title
Email
Steve Hannoy
Sales
shannoy@lsco-inc.com
Denise Beyer
Inside Sales
dbeyer@lsco-inc.com
Table of Contents
Titus
GRD
Pages 1-11
..............................................................................
Thermaflex
Page 28-29
Pages 1-5
Insulated FlexDuct .........................................................
Page 28
HART & COOLEY Grille ............................................
Page 2
Non-Insulated FlexDuct ................................................
Page 29
Dampers .........................................................................
Page 6
Stainless Steel Band .......................................................
Page 29
VAV Air Terminals .........................................................
Page 8-10
Accessories .....................................................................
Page 11
ASI Control
Page 12
Loren Cook
Page 13-18
Hercules
Take Offs .........................................................................
Milcor
Access Doors ........................................................
Page 30
Page 30
Page 30
Page 30
Roof Exhauster ................................................................
Page 13
Accessories ................................................................
Page 14
Gemini Fams ..................................................................
Page 15
Spin-In ..................................................................
Page 31
Accessories ................................................................
Page 16-18
EZ Tap ...................................................................
Page 31
Ruskin
Page 19-21
Fire Dampers ..................................................................
Page 19-20
Access Doors ..................................................................
Page 21
Lindab
Page 22-27
Elbows ............................................................................
Page 22
Reducers .........................................................................
Page 23
Saddle Taps ....................................................................
Page 24
Tees ................................................................................
Page 25
Couplings .......................................................................
Page 25
End Caps ..........................................................................
Sheet Metal Connectors
R & J Manufacturers
Square to Round ...................................................
Page 31
Page 31
Page 31
Gripple
Page 32
Intertape Anchor Duct Tape
Page 32
Advanced Cable Ties
Page 33
Panduit
Page 33
Flanders Filters
Page 34
Pre-Pleat Filters ....................................................
Page 34
Page 26
HD Industrial Fliters ...........................................
Page 34
Take-offs ..........................................................................
Page 26
Shipping Information ..........................................
Page 35
Starting Collar ................................................................
Page 26
Common Formulas ............................................
Pages 36-37
Dampers ...........................................................................
Page 27
Index ..................................................................
Page 38-39
Supply Registers ..............................................................
Page 27
Spiral Duct .....................................................................
Page 27
Langendorf is Proud to Represent many UL, SMACNA, ADC and other Certified Products!
www.ul.com
www.smacna.org
www.greenguard.org
www.ashrae.org
www.flexibleduct.org
Disclaimers:
• Install products per manufacturer’s installation instructions (usually found on manufacturer’s website or call us
for installation instructions)
- Lindab’s Leakage Guarentee Warrenty only valid if installed per Lindab’s installation instructions
• All dimensions in catalog are in inches unless otherwise stated
• All Products shown as we stock them, call us for additional options and products
• Repair parts for many stocked items are also available in stock
Nominal Duct Size
• White Finish (#26)
• Roll Formed Steel
• 3/4” Blade Spacing
• Double Deflection
• Individually Adjustable Blades
• Countersunk Screw Holes
• Front Blades Parallel to Short Dimension
• AG-15 Damper Included (Page 6 )
• White Finish (#26)
• Roll Formed Steel
• 3/4” Blade Spacing
• 35 Degree Fixed Deflection
• Reinforced Corners
• Lay in Frame (No Screw Holes)
• Blades Parallel to Long Dimension
• Optional AG-15 Damper (Page 6)
• Optional TRM Rapid Mount Frame for
Surface Mounting (Page 7)
• Optional TRM Rapid Mount Frame for
Surface Mounting (Page 7)
12 x 4
30 x 8
6x6
36 x 8
8x6
10 x 10
10 x 6
12 x 10
12 x 6
14 x 10
14 x 6
16 x 10
16 x 6
18 x 10
18 x 6
20 x 10
20 x 6
24 x 10
24 x 6
30 x 10
30 x 6
36 x 10
36 x 6
12 x 12
8x8
14 x 12
10 x 8
16 x 12
12 x 8
18 x 12
14 x 8
24 x 12
16 x 8
30 x 12
18 x 8
36 x 12
Nominal Duct Size
Module
22 x 6
24 x 8
22 x 8
24 x 10
22 x 10
24 x 12
22 x 12
24 x 14
22 x 22*
24 x 24
* Indicates that fitting damper is in stock
Nominal Duct Size
* Indicates that fitting damper is in stock
• Matches general appearance of parabolic
lighting fixtures
20 x 8
24 x 8
14 x 14
• White Finish (#26)
• Roll Formed Steel
• 3/4” Blade Spacing
• 35 Degree Fixed Deflection
• Reinforced Corners
• Countersunk Screw Holes (Surface Mount)
• Blades Parallel to Long Dimension
• Optional AG-15 Damper (Page 6)
• White Finish (#26)
• Aluminum Border
• 1/2” x 1/2” x 1/2” Aluminum Core
• High Free Area Core
• Minimized Pressure Drop
• Lay in Border
8x4
10 x 4
8x4
12 x 10
10 x 4
14 x 10
6 x 6*
16 x 10
8x6
24 x 10
10 x 6
12 x 12*
12 x 6
14 x 12
14 x 6
18 x 12
16 x 6
24 x 12
20 x 6
30 x 12
32 x 6
36 x 12
8 x 8*
14 x 14*
10 x 8
16 x 16*
12 x 8
18 x 18*
14 x 8
24 x 18
16 x 8
30 x 18
18 x 8
24 x 24
24 x 8
30 x 24
10 x 10*
36 x 24
Nominal Duct Size
Module
22 x 10
24 x 12
22 x 22*
24 x 24
22 x 46
24 x 48
• White Finish (#26)
• Aluminum Border and Filter Frame (1 inch)
• 1/2” x 1/2” x 1/2” Aluminum Core
• High Free Area Core
• Minimized Pressure Drop
• Lay in Border
• Hidden Screw Holes
• 1” Filter (optional) See Page 34
Nominal Duct Size
Module
20 x 20
24 x 24
• Optional TRM Rapid Mount Frame for
Surface Mounting (Page 7)
• White Finish (#26)
• Roll Formed Steel
• 3/4” Blade Spacing
• 35 Degree Fixed Deflection
• Lay in Border
• Blades Parallel to Long Dimension
• 1” Filter (optional) See Page 34
• Optional TRM Rapid Mount Frame for
Surface Mounting (Page 7)
• Steel construction
• Lanced face design
• Flushed, removable face with concealed latches and
hinges, can be installed in any direction
• Uses 1’ thick disposable filters (not included)
• Bright White Finish
2
Nominal Duct Size
Module
20 x 20
24 x 24
Nominal Duct Size
20 x 20
Pattern Contollers (#22)
•Discharge Pattern is adjustable to vertical
and 1, 2, 3, or 4-way horizontal
•Lay in Border
•Heavy Gauged Steel Backpan and Steel
Panel
• Optional TRM Rapid Mount Frame for
Surface Mounting (Page 7)
•White Face w/ Black Backpan and Black
Pattern Contollers (#22)
•Discharge Pattern is adjustable to vertical
and 1, 2, 3, or 4-way horizontal
Nominal Duct Size
Module Size
6
12 x 12
6
12 x 24
6
20 x 20
8
20 x 20
10
20 x 20
12
20 x 20
14
20 x 20
6
24 x 24
8
24 x 24
10
24 x 24
12
24 x 24
14
24 x 24
16
24 x 24
Nominal Duct Size
Module
6
24 x 24
8
24 x 24
10
24 x 24
•Lay in Border
12
24 x 24
14
24 x 24
•Heavy Gauged Steel Backpan and Steel
Panel
16
24 x 24
• Optional TRM Rapid Mount Frame for
Surface Mounting (Page 7)
•White Face w/ Black Backpan (#22)
Nominal Duct Size
Module Size
10 x 10
12 x 12
10 x 22
12 x 24
18 x 18
20 x 20
22 x 22
24 x 24
•Lay in Border
•Heavy Gauged Steel Backpan and Steel
Panel
• Optional TRM Rapid Mount Frame for
Surface Mounting (Page 7)
•White Face w/ Black Backpan (#22)
•Lay in Border
Neck Size
Module
22 x 22
24 x 24
•Heavy Gauged Steel Backpan and Steel
Panel
• Optional TRM Rapid Mount Frame for
Surface Mounting (Page 7)
•Lay in Border
•No Backpan
Module
24 x 24
• Optional TRM Rapid Mount Frame for
Surface Mounting (Page 7)
3
Surface Mount
Lay-in
Nominal Duct Size
Frame
Pattern
6x6
Surface Mount
Bevel Drop Face
Lay-in
1 way
2 way Corner
2 way Opposite
3 way
4 way
9x9
Surface Mount
Bevel Drop Face
Lay-in
1 way
2 way Corner
2 way Opposite
3 way
4 way
12 x 12
Surface Mount
Bevel Drop Face
Lay-in
1 way
2 way Corner
2 way Opposite
3 way
4 way
15 x 15
Surface Mount
Bevel Drop Face
Lay-in
1 way
2 way Corner
2 way Opposite
3 way
4 way
18 x 18
Surface Mount
Bevel Drop Face
Lay-in
1 way
2 way Corner
2 way Opposite
3 way
4 way
1Way
2 Way Opposite
2 Way Corner
• White Finish (#26)
• Fixed Discharge
• Optional square to round adapter (Page 31)
• Optional AG-95 Damper (Page 6)
4 Way
3Way
• White Finish (#26)
• Deliver supply air in a true 360 degree
pattern
Nominal Duct Size
Module
6
24 x 24
• excellent performance in VAV systems
8
24 x 24
10
24 x 24
12
24 x 24
14
24 x 24
Nominal Duct Size
Module
6
24 x 24
• Optional D-100/AG-75 Damper
(Page 6)
• Optional R-6 Molded Insulation (Page 7)
• Optional TRM Rapid Mount Frame for
Surface Mounting (Page 7)
White Finish (#26)
• Fixed Discharge Pattern
• For Variable Air Volume systems
(excellent turn down for VAV systems)
• Optional D-100/AG-75 Damper
(Page 6)
• Optional R-6 Molded Insulation (Page 7)
• Optional TRM Rapid Mount Frame for
Surface Mounting (Page 7)
4
8
24 x 24
10
24 x 24
12
24 x 24
14
24 x 24
• #26 White Tees, Black Pattern Controllers
Length
Slots
48"
2
48"
3
48"
4
72"
2
72"
3
72"
4
• Project a uniform blanket of air that
adheres to the ceiling even at low flow
rates. Excellent for VAV Applications.
• Direction and Volume are adjustable by
moving the pattern controllers
• Aluminum
• 1” Slot
• Border Style 2A
• White Tees w/ Black Pattern Controllers
• Lay in Border
• Non-insulated
• All Stocked have 1” Slots
• Optional PF Plaster Frame for Surface Mount(Page 7)
TBD10
• Aerodynamically Curved Blades
• High Capacity
TBD80
• Gasket Edge Blade (directional control)
• Airflow Direction is Adjustable through Face
Dimensions
Inlet
Option
Diffuser
L
W
H
Inlet
A
B
Option
No. Slots
No. Tees
TBD 10
24”
2”
8”
6”
6 1/4”
5 1/4”
1
1
1
TBD 10
24”
4”
8”
6”
6 1/4”
5 1/4”
5
2
2
TBD 10
24”
4”
8”
8”
9 3/8”
5 1/4”
3
2
3
TBD 10
24”
4”
8”
8”
9 3/8”
5 1/4”
5
2
2
TBD 10
48”
2”
8”
6”
6 1/4”
5 1/4”
1
1
1
TBD 10
48”
4”
8”
8”
9 3/8”
5 1/4”
3
2
3
TBD 10
48”
4”
8”
8”
9 3/8”
5 1/4”
5
2
2
TBD 10
48”
4”
8”
10”
12 1/2”
5 1/4”
3
2
3
TBD 10
48”
4”
8”
10”
12 1/2”
5 1/4”
5
2
2
TBD 10
48”
4”
8”
12”
15 9/16”
5 1/4”
5
2
2
TBD 80
48”
6”
8”
10”
12 1/2”
5 1/4”
3
3
4
TBD 80
48”
8”
8”
12”
15 9/16”
5 1/4”
3
4
5
5
Nominal Duct Size
6x6
8x8
• Mill Finish
10 x 10
• Galvanized Steel
14 x 14
12 x 12
16 x 16
• Uses Steel S-clips for easy Mounting and
Removal
18 x 18
22 x 22
• Slot Operated
• For use with 300/350 Grilles and Registers
Nominal Duct Size
6x6
• Mill Finish
9x9
• Galvanized Steel
12 x 12
15 x 15
• Neck Mounted
18 x 18
22 x 22
• Operating Lever Accessibility
• Uses Sheet Metal Screws for Mounting
• For use with TDC Diffusers
•Opposed Blade (four sets)
• Mounted Directly into Hard Duct above
Diffuser Neck
• Adjustable from face side of Diffuser
Nominal Duct Size
14
16
• For use with PAS, TMS, or OMNI Diffusers
Nominal Duct Size
6
• Gang operated radial blades
• Mounted Directly on the diffuser neck
• Used with Flex Duct or where height is limited
6
8
10
12
14
• Insulation is R-6 where blanket has most depth
• 1” clearance on each side of neck for insulated duct connection
Size
24 x 24
• Fits TMS and OMNI, size 24 x 24
• Die cut for various neck sizes
• To convert lay-in diffusers to surface mount
Module Size
12 x 12
• For installation in Plaster and Sheet Rock Ceilings
20 x 20
24 x 12
• Similar features as a T-bar installation
24 x 24
• Adjustable fastening clips
• “Access Door” alternative for entry to the plenum
space above the ceiling (by lifting lay-in air device)
• To convert lay-in plenum diffusers (TBD10/80) to surface mount
• For installation in Plaster and Sheet Rock Ceilings
• Similar features as a T-bar installation
• Adjustable fastening clips
Length
Slots
24
1
24
2
48
1
48
2
48
3
48
4
7
Standard Features
• Titus AeroCross multi-point, center averaging velocity sensor for accuracy
• 1/2” 2lb matte face lining standard
• Beaded inlet collar for consistent roundness
• 22 gauge casing with slip and drive connections standard
• Pressure independent control
• TA1 Controller for all standard control strategies (see below)
• 24 Vac tri-state damper actuator
• Operates up to 3 stages of reheat
• Controls 0-10 Vdc proportional hot water valves
• Controls 24 Vac on/off auxiliary heat
Optional Features
• Water Coils (Page 11)
• Thermostat (Page 11)
Control Strategy
Control Code
Thermostat
Cooling Only
AT31
102696-01 (CTE-5101)
Additional Components Required
None
Cooling With Electric Heat
AT33
102696-04 (CTE-5104)
None
Cooling with Auxilary Heat
AT33
102696-04 (CTE-5104)
None
Heating/Cooling Autochangeover
AT34
102696-03 (CTE-5103)
103065-01 (Duct Thermistor)
Cooling with Prop Hot Water Heat
AT35
102696-04 (CTE-5104)
None
Cooling with Marning Warmup
AT36
102696-01 (CTE-5101)
103065-01 (Duct Thermistor)
Cooling with Morning Warmup*
AT36-1
102696-01 (CTE-5101)
101618-01 (2 Pole Relay)
* Requires External Signal
8
Inlet Size
cfm Range
D
G
H
L
M
W
6
0-500
5 7/8
7 3/8
8
15 1/2
3 3/8
12
8
0-900
7 7/8
7 3/8
10
15 1/2
3 3/8
12
10
0-1400
9 7/8
5 3/8
12 1/2
15 1/2
3 3/8
14
12
0-2000
11 7/8
5 3/8
15
15 1/2
3 3/8
16
14
0-3000
13 7/8
5 3/8
17 1/2
15 1/2
3 3/8
20
16
0-4000
15 7/8
5 3/8
18
15 1/2
3 3/8
24
Standard Features
• Aerocross Flow Sensor
• Titus II Controller
• Pneumatic Actuator
• Multiple Control Strategies
• 1/2” 2lb Density Liner
• 22 Gauge Housing
• Right Hand Configuration
Optional Features
• Water Coils (Page 11)
• Thermostat (Page 11)
• SteriLoc Liner (Rigid Foil Faced)
Standard
Control Strategy
Optional
Control Code
Controller
Thermostat
Restrictor Tee
High Pressure Selector
Hot Water Valve
Cooling Only
DA/NO
00
Titus II
CTC.1001-10 (DA)
HFO-0010
------------------------
DA/NC
00
Titus II
CTC.1001-10 (DA)
HFO-0010
------------------------
RA/NO
00
Titus II
CTC.1002-10 (RA)
HFO-0010
------------------------
RA/NC
00
Titus II
CTC.1002-10 (RA)
HFO-0010
------------------------
DA/NO
00
Titus II
CTC.1001-10 (DA)
HFO-0010
------------------------
Normally Open
DA/NC
00
Titus II
CTC.1001-10 (DA)
HFO-0010
------------------------
Normally Open
Cooling (Hot Water Reheat)
RA/NO
00
Titus II
CTC.1002-10 (RA)
HFO-0010
------------------------
Normally Closed
RA/NC
00
Titus II
CTC.1002-10 (RA)
HFO-0010
------------------------
Normally Closed
DA/NO
00
Titus II
CTC.1001-10 (DA)
HFO-0010
------------------------
DA/NC
00
Titus II
CTC.1001-10 (DA)
HFO-0010
------------------------
Cooliong (Electric Reheat)
RA/NO
00
Titus II
CTC.1002-10 (RA)
HFO-0010
------------------------
RA/NC
00
Titus II
CTC.1002-10 (RA)
HFO-0010
------------------------
DA/NO
00
Titus II
CTC.1001-10 (DA)
HFO-0010
RCC-1008
DA/NC
00
Titus II
CTC.1001-10 (DA)
HFO-0010
RCC-1008
Cooling (Morning Warmup- Remote Signal)
RA = Reverse Acting
DA= Direct Acting
NO= Normally Open
NC=Normally Closed
Inlet Size
cfm Range
D
G
H
L
M
W
6
0-500
5 7/8
7 3/8
8
15 1/2
3 3/8
12
8
0-900
7 7/8
7 3/8
10
15 1/2
3 3/8
12
10
0-1400
9 7/8
5 3/8
12 1/2
15 1/2
3 3/8
14
12
0-2000
11 7/8
5 3/8
15
15 1/2
3 3/8
16
14
0-3000
13 7/8
5 3/8
17 1/2
15 1/2
3 3/8
20
16
0-4000
15 7/8
5 3/8
18
15 1/2
3 3/8
24
9
Standard Features
• Standard Box: without controls
• Aerocross Flow Sensor
• Control Enclosure (Field Mounted Controls)
• 1/2” 2lb Density Liner
• 22 Gauge Housing
• Right Hand Configuration
Optional Features
• Water Coils (Page 11)
• SteriLoc Liner (Rigid Foil Faced)
• TDI /ASI Digital Controls (Page 12)
Optional Titus Control Strategies
Control Strategy
Control Code (Personality)
Controller
Standard Wall Sensor
Cooling Only
1
ASIC/1-8055
WS-001
VAV w/ 1 Stage Electric ReHeat
2
ASIC/1-8055
WS-001
2
3
ASIC/1-8055
WS-001
3
4
ASIC/1-8055
WS-001
VAV w/ Hot Water ReHeat
5
ASIC/1-8055
WS-001
Additional Digital Components (Page 13)
10
Inlet Size
cfm Range
D
G
H
L
M
W
6
0-500
5 7/8
7 3/8
8
15 1/2
3 3/8
12
8
0-900
7 7/8
7 3/8
10
15 1/2
3 3/8
12
10
0-1400
9 7/8
5 3/8
12 1/2
15 1/2
3 3/8
14
12
0-2000
11 7/8
5 3/8
15
15 1/2
3 3/8
16
14
0-3000
13 7/8
5 3/8
17 1/2
15 1/2
3 3/8
20
16
0-4000
15 7/8
5 3/8
18
15 1/2
3 3/8
24
• 1/2” O.D. copper tubes, 0.016 thick wall
• Aluminum plate fins, 10 per inch
• 20 Gauge galvanized steel casing
• Copper male solder connections
• Connection is slip and drive to duct work down stream of terminal
• Leak tested to 300 PSIG
• Max working pressure: 240 PSIG
• Max 200 degree F water
Model
VAV Box Inlet Size
Rows
Height (H)
Width (W)
Length
(L)
A
B
C
D
WC-SD1
6
1
8
12
5
3
6 1/4
0
1/2
1/2
WC-SD1
8
1
10
12
5
3
8 3/4
0
WC-SD1
10
1
12 1/2
14
5
4 1/4
10 7/8
1 1/4
7/8
WC-SD1
12
1
15
16
5
4 1/4
13 3/8
1 1/4
7/8
WC-SD1
14
1
17 1/2
20
7 1/2
4 1/4
15 7/8
1 1/4
7/8
WC-SD1
16
1
18
24
7 1/2
4 1/4
15 7/8
1 1/4
7/8
WC-SD2
6
2
8
12
5
4 1/4
6 7/8
0
7/8
WC-SD2
8
2
10
12
5
4 1/4
9
1 1/8
7/8
WC-SD2
10
2
12 1/2
14
5
4 1/4
11 1/2
1 1/8
7/8
WC-SD2
12
2
15
16
5
4 1/4
14
1 1/8
7/8
WC-SD2
14
2
17 1/2
20
7 1/2
4 1/4
16 1/2
1 1/8
7/8
WC-SD2
16
2
18
24
7 1/2
4 1/4
16 1/2
1 1/8
7/8
• Designed for Proportional Control of Value & Damper Actuators
• Throttling Range is Factory set to 3°F but is Field Adjustable up to 12°F
• Dirct & Reverse Acting Models available
• External Restrictor required on Single Pipe Models
• Available Options Include Vertical Scale Plates, °C Scale Plates and Metal Covers
Model
Description
Action
Set Point Range
Color
Restrictor Tee
Drywall
Mounting Kit
2 x 4 Almond Back Plate
(For Mounting in 2 x 4 Electric Box)
CTC-1611
One Pipe Pneumatic
Direct Acting
55°F-85°F
Almond
HFO-0010
HMO-0023
HMO-5024
CTC-1612
One Pipe Pneumatic
Reverse Acting
55°F-85°F
Almond
HFO-0010
HMO-0023
HMO-5024
CTC-1621
Two Pipe Pneumatic
Direct Acting
55°F-85°F
Almond
---------
HMO-0023
HMO-5024
CTC-1622
Two Pipe Pneumatic
Reverse Acting
55°F-85°F
Almond
---------
HMO-0023
HMO-5024
11
Configurable System Controllers
ASIC/2-8040
ASIC/2-7040
Model
Universal Inputs
Binary Relay Outputs
Analog Outputs
Binary Triac Outputs
10 Year Hardware Clock
ASIC/2-7040
16
12
8
---------------------
Yes
ASIC/2-8040
8
3
4
5
Yes
Pre-Programmed Packaged AC Controller
ASIC/1-8655
Model
ASIC/1-8655
Sequences
Binary Relay Outputs
1 & 2 Stage Heat Pumps
1 & 2 Stage Air Conditioner
Analog Outputs
Additional Standard Features
2
0-10 Vdc
Modulating Economized CO2 Demand Ventilation
Auxilary Heating/Cooling
Lighting Control
8
Variable Air Volume Controller
ASIC/1-8055
Model
Sequences
ASIC/1-8055
Cooling Only
Hot Water or Electric Heat
Intermittant or Constant Fan
Dual Duct
Binary Triac Outputs
ASI Controls
12
8
Universal Binary/
Analog Inputs
8
Air Flow Sensor
Additional Standard Features
On Board
Auto-Changeover
Lighting Control
Variable User Adjust
After Hours Override
Accessories
Model
Description
Functionality
SINC/1-1030
Portable System Interface
Provides communication between a PC or laptop and the ASI Network
SINC/3-3000
Multi-Port System Interface
Provides communication between a host computer/modem and the ASI Network
Etherlink
TCP/IP System Interface
Provides communication between a host computer and the ASI Network via a
corperate LAN or WAN using TCP/IP
ASI Expert
Configuration Software
Windows based graphical configuration software
•Downblast Centrifugal Exhaust Ventilator
•Roof Mounted
• Optional Damper (Page 14)
• Optional Roof Curb (Page 14)
• Optional Fan Speed Control (Page 117)
• Optional Disconnect (Page 14)
ACED
• Direct Drive
ACEB
•Belt Drive
•Less Motor and Drive
•Fans will be Set to your CFM, Horsepower, and Voltage Specifications
Speci cations
Capacity (CFM)
Size
A
B
C
G
T Sq.
Roof Opening
Mtr HP
@ 1/8” SP
@ 1/4” SP
@ 3/8” SP
70ACEB
2 7/8
23 9/16
21 1/8
2
18
13 1/2 x 13 1/2
1/6, 1/4
96-402
70-379
63-356
@ 1/2” SP
95-331
80ACEB
2 7/8
23 9/16
21 1/8
2
18
13 1/2 x 13 1/2
1/6, 1/4
221-842
102-750
356-704
394-650
100 ACEB
2 7/8
23 9/16
21 1/8
2
18
13 1/2 x 13 1/2
1/6, 1/4
293-1093
497-1050
564-1011
389-973
120ACEB
1 13/16
28 7/16
26 7/8
2
20
15 1/2 x 15 1/2
1/6, 1/4, 1/3
709-1729
515-1668
720-1606
937-1541
135ACEB
2 3/16
28 7/16
27 1/4
2
20
15 1/2 x 15 1/2
1/6, 1/4, 1/3, 1/2
1128-2330
983-2258
640-2184
960-2108
150ACEB
3 1/16
32 7/8
28 7/8
2
24
19 1/2 x 19 1/2
1/6, 1/4, 1/3, 1/2, 3/4
1460-3096
1288-3014
1024-2930
1224-2844
165ACEB
3 9/16
32 7/8
29 3/8
2
24
19 1/2 x 19 1/2
1/6, 1/4, 1/3, 1/2, 3/4
1682-3504
1464-3397
1356-3288
1525-3175
180ACEB
3 15/16
37 11/16
34 1/2
3
30
25 1/2 x 25 1/2
1/6, 1/4, 1/3, 1/2, 3/4, 1, 1-1/2, 2
2123-5419
1875-5326
1539-5229
1759-5131
Speci cations
Capacities
Size
A
B
C
G
T Sq.
Roof Opening
Mtr HP
@ 1/8” SP
@ 1/4” SP
@ 3/8” SP
70C10DH
1 3/4
13 5/8
13 13/16
2
18
13 1/2 x 13 1/2
1/25
121
---
---
@ 1/2” SP
---
70C15DH
1 3/4
13 5/8
13 13/16
2
18
13 1/2 x 13 1/2
1/20
249
194
135
---
90C10DH
2 1/2
18 3/4
16 13/16
2
18
13 1/2 x 13 1/2
1/25
417
232
---
---
90C15DH
2 1/2
18 3/4
16 13/16
2
18
13 1/2 x 13 1/2
1/8
758
649
509
411
100C10DH
2 1/2
18 3/4
16 13/16
2
18
13 1/2 x 13 1/2
1/25
510
354
191
---
100C15DH
2 1/2
18 3/4
16 13/16
2
18
13 1/2 x 13 1/2
1/8
855
766
667
552
13
• Extruded Aluminum Frame, Aluminum
Blades and Hinge Pins w/ Brass Bushings
• For Use with ACED and ACEB
Model
ACE Units
Size
BD-12
60 70 80 90 100
11 3/4 x 11 3/4
BD-14
120 135
13 3/4 x 13 3/4
BD-18
150 165
17 3/4 x 17 3/4
BD-24
180 195 210 225 245
23 3/4 x 23 3/4
• Treated Wood Nailer
• Continuously Welded Corners
• 18 Gauge Galvanized Steel
• 1 1/2” - 3lbs Density Thermal and Acoustical
Insulation
• 13 1/2” High
Size
AC Unit Sizes
16
60 70 80 90 100
Roof Opening
13 1/2
18
120 135
15 1/2
22
150 165
19 1/2
28
180 195 210 225 245
25 1/2
34
270 300
31 1/2
40
330 365
37 1/2
• Damper shelf
• Shipped Loose for Field Mounting
• Certifications: UL/CSA
• Commercial Grade, Heavy Duty
Model
Type
*Vendor
* Vendor Model
Voltage
Phase
Capacity Range
Enclosure
Disc 115-1/2
Single Pole Toggle
Leviton
CS115-2
115
1
Up Thru 1/2 HP
2 x 4 Galvanized Handy Box
Disc 115-3/4
Single Pole Toggle
Carling Switch
2GA94-73
115
1
3/4 HP
2 x 4 Galvanized Handy Box
Disc 115-1/2
Single Pole Toggle
Leviton
1222-S
115
1
1 HP
2 x 4 Galvanized Handy Box
Disc 230-1
Single Pole Toggle
Carling Switch
2GA94-73
208-230
1
Up Thru 1 HP
2 x 4 Galvanized Handy Box
Disc 480-2
Three Pole Toggle
Carling Switch
HK274-73
208-480
3
Up Thru 2 HP
4 x 4 Galvanized Handy Box
• or equivalent from another manufacturer
14
• Centrifugal Exhaust Fan
• Direct Drive
• Ceiling Mounted
• Plastic Frame Provided
• Used in Clean Air Exhaust Applications requiring
Capacity Ranges of 50 to 251 CFM
Optional Accessories
• Roof Cap/Relief Vent (Page 16)
• Roof Jack (Page 16)
• Wall Cap (Page 17)
• Fan Speed Control (Page 17)
• Gemini Isolator Kit (Page 18)
• Brick Vent (Page 18)
• Static Pressure Capacity Ranges from free air - .875 in. of WG
• Uses Single Speed Motors
• Easily Converted from Ceiling to Inline by Installing a Single
Panel in Place of Grille and Removing Back Plate
Capacities
Model
Max Watts/ BHP
RPM
A
B
@ 0” SP
@ 1/8” SP
@ 1/4” SP
GC-120
35
1200
13 1/4
14 3/4
92
74
50
@ 1/2” SP
---
GC-140
70
1500
13 1/4
14 3/4
110
109
109
106
GC-160
113
1500
13 1/4
14 3/4
154
168
173
166
GC-180
192
1500
13 1/4
14 3/4
253
249
245
235
• Centrifugal Exhaust Fan
• Direct Drive
• Ceiling Mounted
• Used in Clean Air Exhaust Applications requiring Capacity Ranges
• 74 to 852 CFM (GC220-740)
• 680-1807 CFM (GC-820-960)
• Static Pressure Capacity Ranges from
• free air - .875 in. of WG (GC220-740)
• free air - .625 in. of WG (GC-820-960)
Optional Accessories
• Roof Cap/Relief Vent (Page 16)
• Roof Jack (Page 16)
• Wall Cap (Page 17)
• Fan Speed Control (Page 17)
• Gemini Isolator Kit (Page 18)
• Brick Vent (Page 18)
• Uses
• One or Two Speed Motors (GC220-740)
• Three Speed Motor (GC-820-960)
• Easily Convertible from Ceiling to Inline by Relocating One Panel
• Single Scroll Fan (GC220-740) or Double Scroll Fan (GC-820-960)
Housing
Outlet
Steel Grille
Capacities
Model
Max
Watts/
BHP
RPM
L
W
H
A
B
J
K
@ 0” SP
@ 1/8” SP
@ 1/4” SP
GC-220
41
1050
12 3/8
9 3/4
9 3/4
8
6
12 5/16
9 11/16
120
104
73
---
GC-320
75
1365
12 3/8
10 3/4
10 3/4
8
6
12 5/16
10 11/16
217
202
182
---
GC-420
170
1145
17
11 7/8
11 7/8
8
6
16 15/16
11 15/16
327
287
260
202
GC-520
172
1205
17
11 7/8
11 7/8
8
6
16 15/16
11 15/16
356
344
332
301
GC-620
233
960
17
11 7/8
11 7/8
10 1/2
4 3/4
16 15/16
11 15/16
451
428
400
297
GC-720
301
1375
17
11 7/8
11 7/8
10 1/2
4 3/4
16 15/16
11 15/16
709
682
653
578
GC-820
287/.162
780
27
14 11/16
14 11/16
20
6
27
14 1/2
944
925
904
830
GC-920
430/.282
925
31
14 11/16
14 11/16
24 1/4
6
31
14 1/2
1471
1415
1356
1190
@ 1/2” SP
15
Curb Cap Base
• Continuously Welded Corners
Flat Plate Base
• All Aluminum Construction
• 1 1/2” - 3lbs Density Thernal and Acoustical
Insulation
• Anti-backdraft Flange
• Birdscreen
Gravity Application
Temperature Difference
10
10
20
Wind Speed
5
10
5
Stack Height
Size
Throat
8
0.394
10
20
30
40
10
20
CFM
96
104
30
40
10
118
178
182
10
20
CFM
111
20
30
40
10
CFM
187
191
104
118
20
131
143
182
191
Exhaust Application
Pressure Drop (in WG)
Size
Throat
0.050
0.100
0.125
0.150
0.200
0.250
0.300
0.375
0.500
473
518
579
669
CFM
8
0.394
212
299
334
366
Model
Gemini Units
Throat Dia.
Type
PR8
120-520
8 19/32
Curb Mount
PR8F
120-520
8 19/32
Flat Base
• Corrosion Resistant Galvanized Steel
• Black Baked Enamel Finish
• 1/2” Birdscreen
• Round Throat (RJR100) or Rectangle
(RJ200)
• 14 1/2” x 18 3/4” Base
• 6 1/2” Tall
16
423
Model
Gemini Units
RJR100
120-180
Throat Size
6 Dia
RJ200
220-520
10 1/4 X 10 3/4
30
40
200
208
CFM
WCG
• WCG are Galvanized Steel
• WCG have 1/2” Birdscreen
• Corrosion Resistant
Model
Gemini Units
A Sq
B
C Dia
D
WCG-2
220-520
10 5/16
7 3/16
6 3/8
8 5/16
WCG-6
620-740
12 13/16
6
5
10 13/16
WCG-8
820-860
22 5/16
7 3/16
6 3/16
20 5/16
WCG-9
920-960
26 9/16
7 15/16
6 15/16
24 9/16
WCR
• WCR (round w/ damper) are Aluminum
Model
Gemini Units
A Sq
B
C Dia
D
WCR6
120-340
8
7
6
8 1/2
12 3/4
E
WCR8
220-520
10
9
8
8 1/2
14 1/4
• Available 5 AMP (GC 100-800) and 10 AMP (GC 900)
• Available only on 115V and 230V Shaded Pole or Permanent Split Capacitor Motors
• Allows operation of AC Units from 100% of capacity to 50%
• Excellent Energy Conservation and Lower Sound Levels when 100% operation is not needed
• Available only on 115V and 230V shaded pole or permanent split capacitor motors
• Not available on 1140 RPM and 1725 RPM motors
17
• Used for Gemini ceiling and inline units 120-740
• Bushings are made of resilient thermoplastic
• Bushing and eyelets are sized to be used with common 1/4” X 20 tpi all thread
• Standard Gemini brackets easily accomadate isolator bushings
• Flanged nuts eliminate the need for additional washers and provide simplified field assembly
Model
Fits Gemini Series
A
BV1
120-180
4 3/4
BV5
520-720
7 3/4
• .100” minimum wall thickness
• Frame depth is 4”
• 1/8” mortar ribs on top and bottom of frame (adds 1/4” to nominal height)
• Blades: 6063T5 extruded aluminum, 45° angles, overlap for optimum visual screening
• 18 x 16 mesh aluminum insect screen
• Actual Size, not Undersized
• Grease capture and containment system to Prevent Accumulation on the roof
• Attaches to Lowest Point on Fan
• Biodegradable
• UV Protected
• Non Woven Fibers
• Retrofit Kits Available
18
Model
Size
Frame Depth
CFDR3.5
6”
6 1/2”
CFDR3.5
8”
6 1/2”
CFDR3.5
10”
6 1/2”
CFDR2
12”
8 1/2”
CFDR2
14”
8 1/2”
CFDR2
16”
11 1/2”
• 20 gage galvanized steel blades
• UL Classified insulation (as required)
• 20 gage galvanized steel frame
• Mill Finish
• Actual Size to fit over Diffuser Neck
• 20 gage galvanized steel blades
• UL Classified insulation (as required)
• 20 gage galvanized steel frame
Model
Size
Frame Depth
CFD2
22 x 22
3”
• Mill Finish
• Actual Size to fit over Diffuser Neck
• Thermal Blanket
• Also in 3” extension piece
• Size 24 x 24
• Neck to be Field Cut
19
Nominal Duct Size
6x6
• UL555 1-1/2 Hour Rated Classified Curtain Type Fire Damper
• Galvanized steel construction
• Frame: 20 gage galvanized steel channel
• Blades: 24 gage galvanized curtain type in air stream
• Closure Springs: 301 stainless steel constant force type
• Fusible Link: 165° (standard)
• Both Horizontal and Vertical Mounting
• Dampers fabricated approximately 1/4” less than given duct size
Nominal Duct Size
6x6
16 x 10
8x6
18 x 10
10 x 6
24 x 10
12 x 6
12 x 12
8x8
14 x 12
10 x 8
16 x 12
12 x 8
18 x 12
14 x 8
20 x 12
16 x 8
24 x 12
10 x 10
14 x 14
12 x 10
16 x 16
14 x 10
24 x 24
18 x 10
10 x 6
24 x 10
12 x 6
12 x 12
8x8
14 x 12
10 x 8
16 x 12
12 x 8
18 x 12
14 x 8
20 x 12
16 x 8
24 x 12
10 x 10
14 x 14
12 x 10
16 x 16
14 x 10
24 x 24
• UL555 Classified 1-1/2 Hour Rated Static Curtain Type Fire Damper
• Integral 12”, 20 gage galvanized steel sleeve
• Includes 1-1/2” Fast Angle, one side
• Galvanized steel construction
• Frame: 20 gage galvanized steel channel
• Blades: 24 gage galvanized curtain type in air stream
• Closure Springs: 301 stainless steel constant force type
• Fusible Link: 165° (standard)
• Both Horizontal and Vertical Mounting
• Dampers fabricated approximately 1/4” less than given duct size
D = Nominal Duct Size
Width = D + 2
6
8
H = Height
8 3/4
8
10
10 3/4
10
12
12 3/4
12
14
15 3/4
14
16
17 3/4
16
18
19 3/4
• UL555 1-1/2 Hour Rated Classified Curtain Type Fire Damper
• Sealed round transitions for medium pressure systems
Galvanized steel construction
Frame: 20 gage galvanized steel channel
Blades: 24 gage galvanized curtain type out of air stream
Closure Springs: 301 stainless steel constant force type
Fusible Link: 165° (standard)
Both Horizontal and Vertical Mounting
• Dampers fabricated approximately 1/8” less than given duct size
• UL555 Classified 1-1/2 Hour Rated Static Curtain Type Fire Damper
• Sealed round transitions for medium pressure systems
D = Nominal Duct Size
• Integral 12”, 20 gage galvanized steel sleeve
6
• Includes 1-1/2” Fast Angle, one side
8
• Galvanized steel construction
10
• Frame: 20 gage galvanized steel channel
12
• Blades: 24 gage galvanized curtain type out of air stream
14
• Closure Springs: 301 stainless steel constant force type
16
• Fusible Link: 165° (standard)
• Both Horizontal and Vertical Mounting
• Dampers fabricated approximately 1/8” less than given duct size
20
16 x 10
8x6
Width = D + 2
H = Height
8
8 3/4
10
10 3/4
12
12 3/4
14
15 3/4
16
17 3/4
18
19 3/4
Duct Size Diameter
Hole Size
Door Size
6
7x3
8x4
8
7x3
8x4
• 16 gage galvanized steel door
10
11 x 7
12 x 8
12
11 x 7
12 x 8
• Synthetic knob with threaded metal inserts
14
11 x 7
12 x 8
16
11 x 7
12 x 8
18
11 x 7
12 x 8
20
11 x 7
12 x 8
24
15 x 11
16 x 12
28
15 x 11
16 x 12
32
15 x 11
16 x 12
36
15 x 11
16 x 12
• 1/2” x 3/8” neoprene gasket
• Mill galvanized finish
• SMACNA Standard Access Doors
• Removable Double Cam Fastening
• Double Skin Door
Size (w x h)
6x6
8x8
• 2 cam locks (16” & under)
4 cam locks (over 16”)
10 x 10
• SMACNA Standard: Water Pressure
Through 12” x 12” : 3” wg
Above 12” x 12” : 2” wg
16 x 16
12 x 12
14 x 14
18 x 18
24 x 24
• 1” (25) fiberglass insulation
Size (w x h)
• SMACNA Standard Access Doors
• Hinged (Continuous Piano Type)
• Double Skin Door
• 1 cam locks (16” & under)
2 cam locks (over 16”)
6x6
8x8
10 x 10
12 x 12
14 x 14
16 x 16
18 x 18
24 x 24
• SMACNA Standard: Water Pressure
Through 12” x 12” : 3” wg
Above 12” x 12” : 2” wg
• 1” (25) fiberglass insulation
• Foam Gasket Seals
21
Diameter
14
16
• 45° elbow
18
• 3 gore standing seam
20
22
• Gore locked and internally sealed
24
• Single-wall galvanized
26
28
• Centerline Radius = 1.5 x Diameter
30
32
Diameter
14
• 90° elbow
16
18
• 5 gore standing seam
20
• Gore locked and internally sealed
22
24
• Single-wall galvanized
26
• Centerline Radius = 1.5 x Diameter
28
30
32
Diameter
4
5
• 45° elbow
• Die Stamped
6
• Continuously stitch welded
7
• Rolled Edges
8
9
• Single-wall galvanized
10
• Centerline Radius = 1.5 x Diameter
12
Diameter
3
• 90° elbow
4
• Die Stamped
6
• Continuously stitch welded
• Rolled Edges
• Single-wall galvanized
• Centerline Radius = 1.5 x Diameter
22
5
7
8
9
10
12
d1
d2
5
4
L (length)
7/8
6
4
1 1/4
• Die Stamped Concentric Reducer
6
5
3/4
• Single-wall galvanized
7
5
1 1/2
7
6
1
8
4
2 1/4
8
5
1 5/8
8
6
1 1/4
8
7
3/4
10
6
2 1/4
10
8
1 1/8
10
9
5/8
12
8
2 1/8
* Fabricated. Others Die Stamped
d1
d2
L (length)
d1
d2
L (length)
12
5
10 1/4
24
16
11 1/2
12
6
8 7/8
24
18
8 7/8
14
6
12 1/8
24
20
6
• Fabricated Concentric Reducer
16
6
14 3/8
24
22
3 1/4
18
10
11 5/8
26
18
10 5/8
• Single-wall galvanized
18
12
8 7/8
26
20
8
18
14
6 1/8
26
22
5
18
16
3 5/8
26
24
3 7/8
20
10
14 1/4
28
18
15 3/8
20
12
11 1/2
28
22
9 7/8
20
14
8 3/4
28
24
7 1/8
20
16
6 1/4
28
26
4 3/8
20
18
3 3/4
30
20
14 3/4
22
12
15 1/4
30
24
12
22
14
12 1/2
30
26
9 1/4
22
16
10
30
28
6 5/8
22
18
7 1/4
32
22
14 1/8
22
20
4 3/8
32
24
11 3/8
24
14
14 1/8
32
28
6 1/8
23
• Die Stamped Saddle Tap
• Radiused Entry
• Single-wall galvanized
Fits Duct Size
D = Branch Dia
Fits Duct Size
D = Branch Dia
4
4
18
18
6
4
18/14
6
8/7
4
20
14
8/7
6
20
18
10
5
20
20
10
10
20/16
10
10/9
4
20/18
8
10/9
6
20/18
16
10/9
8
22
14
12
6
22
18
12
8
22
20
12
10
22
22
12
12
22/18
12
14
10
24
12
14
12
24
14
14
14
24
18
16
12
24
20
16
14
24
22
16
16
24
24
16/14
4
24/18
12
16/14
8
24/22
8
18
14
24/22
10
24/22
16
Fits Duct Size
• 45 Degree
24
D = Branch Dia
4
4
6
4 6
8
4 6 8
• Fabricated Lateral Saddle Tap
10
6 8 10
• Single-wall galvanized
12
5 6 8 10 12
14
5 6 8 10 12 14
16
6 8 10 12 14 16
18
6 8 10 12 14 16 18
20
6 8 10 12 14 16 18
22
6 8 10 12 14 16 18 20
24
6 8 10 12 14 16 18 20 22
• Assembled Tee
• With Fabricated or Die Stamped PSU
• Single-wall Galvanized
d1
d2
L
H
4
4
6
2 5/8
6
6
9
4 1/8
8
8
11
5
10
10
13 3/4
6
12
12
15 3/8
7 1/8
14
14
19
8
16
16
22 1/2
8 7/8
18
18
24 1/2
9 7/8
20
20
26 1/2
10 7/8
22
22
28 1/2
12 7/8
24
24
30 1/2
12 7/8
Diameter
Length
3
3 5/8
4
3 5/8
5
3 5/8
6
3 5/8
7
3 5/8
8
3 5/8
9
3 5/8
10
5 1/8
12
5 1/8
• Used for Joining Fittings (Fitting to Fitting Coupling)
14
5 1/8
16
6 5/8
• Single-wall Galvanized
18
6 5/8
20
6 5/8
22
6 3/4
24
6 3/4
26
6 3/4
28
8 5/8
30
8 5/8
32
8 5/8
• Used for Joining Spiral Ducts
• Single-wall Galvanized
Diameter
Length
3
3/8
4
3/8
5
3/8
6
3/8
7
3/8
8
3/8
9
3/8
10
3/8
12
3/8
14
3/8
16
3/8
18
3/8
20
3/8
22
1/2
24
1/2
26
1/2
28
5/8
30
5/8
32
5/8
25
Diameter
Length
3*
3/8
4
3/8
5
3/8
6
3/8
7
3/8
• End Cap for Spiral Duct
• Single-wall galvanized
8
3/8
10
3/8
12
3/8
14*
3/8
16*
3/8
18*
3/8
20*
3/8
22*
1/2
24*
1/2
26*
1/2
28*
5/8
30*
5/8
32*
5/8
* Fabricated. Others Die Stamped
• Radiused Bellmouth Take-off
• To be installed on flat side i.e. rectangular
duct or plenum
• Single-wall galvanized
Diameter
Length = radius
4
5/8
5
3/4
6
7/8
7
1
8
1
9
1
10
1
12
1
14
1
16
1
Diameter
18
20
26
• Take-off/ Starting Collar
22
• To be installed on flat side i.e. rectangular
duct or plenum
26
• Single-wall galvanized
32
24
28
30
Diameter
4
5
• Balancing Damper
• For use in systems where a complete shutoff of air flow is not required
• Gasketed, shaft-mounted load bearing
bushings
• Integral shaft-blade assembly
• 2” sheet metal insulation stand-off
• Locking blade quadrant w/ damper position
indicator
• Gasketed shaft penetrations to minimize
leakage
• Full fitting body assembly with bead stop
6
8
9
10
12
14
16
18
20
22
24
26
28
30
32
• Single-wall galvanized
Length
13 x 3
13 x 6
17 x 3
• Supply/ Return register
• Adjustable Double Deflection Blades
• Volume Damper designed specifically for
direct mounting on spiral duct
• Register Only
17 x 6
17 x 9
21 x 3
21 x 6
21 x 9
25 x 3
• Rectangular reigster taps are not required
for installation
25 x 6
• Galvanized Steel
33 x 9
33 x 3
33 x 6
41 x 6
49 x 3
49 x 6
49 x 9
Diameter
3
4
5
6
• Spiral lockseam duct
• Flat seam
• Evenly spaced integral seam locking feature
• Double corrugations on all SPIROduct 14”
diameter and larger
7
8
9
10
11
12
14
16
• Single-wall galvanized
18
• Stocked in 10’ lengths
22
20
24
26
28
30
32
27
• Stocked in 25 ft lengths
• Strong Poylester film laminated and encapsulating a heavy corrosion
resistant steel wire helix
• Wire helix suppoorts a thick blanket of fiberglass insulation over a
fiberglass scrim
Diameter
4
9
Pressure Rating (WG)
• Positive: 10 in (4”-16” ID)
6 in (18”-20” ID)
• Negative:1 in (4”-16” ID)
1/2 in (14”-20”)
10
Velocity: 5000 FPM
• Outer vapor barrier is durable black polyethylene
5
• Smooth air tight innercore of polyester is designed for low-medium
pressure systems
7
6
8
12
UL 181 listed Class 1 Air Duct
14
Temp Range: -20°F - 250°F continuous
16
R Value: R-4.2
• Stocked in 25 ft lengths
• Strong Poylester film laminated and encapsulating a heavy corrosion
resistant steel wire helix
• Wire helix suppoorts a thick blanket of fiberglass insulation over a
fiberglass scrim
Diameter
4
• Bi-directional reinforced metalized vapor barrier which will not
unravel
5
• Smooth air tight innercore of polyester is designed for low-medium
pressure systems
7
6
8
9
10
12
UL 181 listed Class 1 Air Duct
Diameter
4
5
6
7
8
Pressure Rating (WG)
• Positive: 16 in (4”-11” ID)
10 in (12”-16” ID)
• Negative:2 in (4”-16” ID)
Velocity: 6000 FPM
Temp Range: -20°F - 250°F continuous
R Value: R-4.2
28
Pressure Rating (WG)
• Positive: 10 in (4”-16” ID)
6 in (18”-20” ID)
• Negative:1 in (4”-16” ID)
1/2 in (14”-20”)
Velocity: 5000 FPM
14
Temp Range: -20°F - 250°F continuous
16
R Value: R-4.2
• Stocked in 25 ft lengths
• Strong woven fiberglass fabric, with flame resistent coating and permanently
bonded to a coated steel wire helix
• Wire helix suppoorts a thick blanket of insulation and provides a double air
seal
9
• Bi-directional reinforced metalized vapor barrier which will not unravel
10
• High pressure flexible duct for use in low-high pressure heating and cooling
systems
12
14
16
UL 181 listed Class 1 Air Duct
18
20
The first Greenguard Certified
flexible duct in HVAC history
Diameter
3
4
5
6
7
8
9
10
12
Pressure Rating (WG)
• Positive: 10 in (2”-14” ID)
• Negative:1 in (2”-14” ID)
• Stocked in 25 ft lengths
• Non-insulated air connector
• Strong woven fiberglass fabric, with flame retardant coating, permanently
bonded to a corrosion resistant steel wire helix
• For use in low-medium pressure heating and cooling systems (alternative
in applications where insulated duct is not required or cannot be used)
14
Velocity: 5000 FPM
UL 181 listed Air Duct Connector
Temp Range: -20°F - 250°F continuous
Diameter
16
18
20
Pressure Rating (WG)
• Positive: 16 in (2”-10” ID)
10 in (12”-20” ID)
• Negative:1 in (2”-20” ID)
Velocity: 6000 FPM
• Stocked in 15 ft lengths
• Non-insulated Class 1 flexible air duct
• Strong woven fiberglass cloth fabric, with permanently bonded to a corrosion
resistant coated spring steel wire helix
• For use in low-high pressure heating and cooling systems (alternative in
applications where insulated duct is not required or cannot be used)
UL 181 listed Class 1 Air Duct
Temp Range: -20°F - 250°F continuous
Snaplock
• Stainless steel band
• Cadmium plated
Fits Flexduct
8
12
• Hex head bolt to attach Thermaflex to metal
fittings
29
• 14 gauge steel frame and door panel
• Standard for the industry
Door Size
Opening
8x8
8 1/4 x 8 1/4
1
10 x 10
10 1/4 x 10 1/4
1
12 x 12
12 1/4 x 12 1/4
1
14 x 14
14 1/4 x 14 1/4
1
16 x 16
16 1/4 x 16 1/4
1
18 x 18
18 1/4 x 18 1/4
1
24 x 24
24 1/4 x 24 1/4
4
• Provides a 100% clear opening with superior
strength, rigidity, and true squareness
• Door panel is mounted to the frame on
concealed spring hinges that open to 175
degrees for complete access without allowing
the door to impact the wall
No. Cams
• 14 gauge frame
• 20 gauge door panel
• 2” mineral fiber insulation between inner
and outdoor panel
• Fire-Rated - carries the UL 1 1/2 hour class
B fire rating
• Continuous type, steel hinge with stainless
steel pin
• Self latching lock
• An adhesive coated gasket that hold the fitting
securely in position during installation and
assures a tight seal
• 1” wide flange allows for easy installation
• 45˚ angle design allows for optimum air
flow
30
A = Diameter
B
C
D
Cut Hole
7
11 1/2
9 1/4
13
7 x 10
8
11 1/2
10 1/4
14
8 x 11
9
11 1/2
11 1/4
15
9 x 12
10
11 1/2
12
15
10 x 12
12
11 1/2
14
17
12 x 14
14
11 1/2
16
19
14 x 16
Door Size
Wall/Ceiling Opening
Locks
12 x 12
12 3/8 x 12 3/8
1
16 x 16
16 3/8 x 16 3/8
1
18 x 18
18 3/8 x 18 3/8
1
24 x 24
24 3/8 x 24 3/8
1
Diameter
Length
Cut Hole
Gauge
4
5 3/4
3 7/8
26
5
5 3/4
4 7/8
26
6
5 3/4
5 7/8
26
7
5 3/4
6 7/8
26
8
7 1/2
7 7/8
26
9
7 1/2
8 7/8
26
10
9 1/2
9 7/8
26
• Used for making round take off connections to rectangular sheet metal duct
• locking grove is die formed and notched for easy installation
12
9 1/2
11 7/8
26
14
13 5/8
13 7/8
24
16
13 5/8
15 7/8
24
18
17 5/8
17 7/8
24
20
17 5/8
19 7/8
24
• Damper is assembled using a spring loaded retractable bearing and positive locking hardware
• Double Quadrant on sizes 8” or Larger
• On inch flanged turn out, adding rigidity to the collar
• Double-faced gasket applied to the flange guarantees a tight seal
• Self-sealing Takeoff - Peel, stick and fasten with sheet metal screws
Diameter
Overall Length
Gauge
6
5 1/2
26
8
5 1/2
26
10
5 1/2
26
12
7
26
14
11
24
16
13 1/2
24
18
18
24
20
18
24
• Double Quadrant on sizes 8” or Larger
Square Dimensions
Diameter
6x6
6
8x8
6
8x8
8
9x9
6
9x9
8
10 x 10
8
• Riveted construction
10 x 10
10
12 x 12
8
• 3” high square with 2 1/2” high collar
12 x 12
10
12 x 12
12
15 x 15
12
15 x 15
14
18 x 18
14
18 x 18
16
18 x 18
18
• 28 gauge galvanized steel
31
Achor AC57 is the first UL-Listed HVAC Cloth Duct Tape for Flexible Duct
• Printed Cloth Tape
AC57
• Polyethylene Coated with Scientifically Designed Adhesive to meet the stringent
requirements of the HVAC contractor
• 2 Inches Wide
• Tensile strength of 50.7 lbs per inch width of tape
• Holds 100g load w/o slipping for 24 hours in a shear adhesion test after exposure of
150°F for 60 days
• Resitance to flame spread and smoke generation
• Resistance to mold growth and humidity
• Resistance to the effects of high temperatures (shows no advers affects after exposure
of 212°F for 60 days)
AC45
• For Applications where High Shear and Low Residue Characteristics are desired
• 48 MM Wide
www.intertapepolymer.com
Model
Size
Color
AC45S
2” x 60 yrds
Silver
UL 181 B
AC57B
2” x 60 yrds
Black
UL 181 B-FX
Gripple
Model
Size
Cable Length
HF0205
HF0210
HF0215
HF0230
No.2
Working Load Limit
100 lbs
LOOP SYTLE
5 ft
10 ft
15 ft
30 ft
HF0305
HF0310
HF0315
HF0330
No.2
Working Load Limit
200 lbs
LOOP SYTLE
5 ft
10 ft
15 ft
30 ft
Self-locking Wire Rope Grip
• The strength of high tensile steel cable
• All ferrules are made from aluminum
• All No. 1 and 2 are pull tested to twice the working load
limit
ALSO NOTE:
Non-standard lengths manufactured and quoted on
request
Toggle and Stud Styles are available with a two weeks
lead time
CORNERS AND CABLE CUTTERS
ARE ALSO STOCKED
• UL Listed
32
UL Rating
• Produced with high quality nylon 6/6
• Angled Tail features finger grips and a stay-tab for easy handling
--allows the tie to be partially closed without engaging the pawl
• The one piece design, transition rails and teeth provide a low
insertion force while maintaining a high tensile strength
• UL 181B-C Rated for Air Handling Spaces
• Complies with New & Future Builiding Codes
• Meets Air Diffusion Council Installation Instruction
• Insures consistent material, smooth edges and 0% mold growth
Model
Color
Length
Width
Thickness
Tie Tensile
Diameter
AL-48-175-8-L
Gray
48.5
.340
.090
175 lbs
14.5
Per Bag
50
AL-36-175-9-L
Natural/White
37.1
.340
.090
175 lbs
11
50
Heavy Duty Tension Tool
• 120lb to 175lb Duct Straps
• Manual Tension Control
• Neatly cuts off Straps
• Metal Construction
• Used for making round take off connections
to rectangular sheet metal duct
• locking grove is die formed and notched for
easy installation
• Damper is assembled using a spring loaded
retractable bearing and positive locking
hardware
33
Common Formulas
General Ventilation
Electrical
Air Quality Method
CFM = People x Outdoor Air Requirmentss (CFM/Person)
Ohm’s Law
Ohms =
where
People =
Occupancy
10000
x Floor Area (ft 2 )
Volts
Amperes
R=
E
I
Vollts
Ohms
I=
E
R
Amperes =
Air Change Method
Volts = Amperes x Ohms
BLDG Volume (ft 3 )
Air Change Frequency
Heat Removal Method
CFM =
A-C Circuit
Suggested Air Changes
 btu 
Heat Removal 

 Hr 
CFM =
1.10 x Temp Diff
Type of Space
Suggested Air Quality
Space
Outdoor Air
Required
E = IR
Occupancy
Air Change
Frequency(mins)
Assembly Halls
3-10
Auditoriums
4-15
Bakeries
1-3
Boiler Rooms
2-4
Bowling Alleys
2-8
1-5
746 x ( Horsepower )
Three Phase Amperes =
1.732 x ( Volts ) x ( Eff ) x ( Power Factor )
Single Phase Amperes =
( Volts ) x ( Eff ) x ( Power Factor )
746 x ( Horsepower )
DC Circuits
Watts = Volts x Amperes
w = EI
(CFM/person)
(people/1000
sq ft)
Auditoriums
15
150
Dry Cleaners
Ballrooms/Discos
25
100
Engine Rooms
Bars
30
100
Factories
Beauty Shops
25
25
1-5
Forges
Classrooms
15
50
1-2
Foundries
Conference Rooms
20
50
1-4
Garages
Correctional Facility Cells
20
20
Generating Rooms
Dormitory Sleeping Rooms
15
20
Glass Plants
1-2
Dry Cleaners
30
30
Gymnasiums
2-10
Gambling Casinos
30
120
Heat Treat Rooms
0.5-1
Game Rooms
25
70
Kitchens
1-3
Hardware Stores
15
8
Laundries
2-5
Hospital Operating Rooms
30
20
Locker Rooms
2-5
Hospital Patient Rooms
25
10
Machine Shops
3-5
Laboratories
20
30
Mills (Paper)
2-3
Libraries
15
20
Mills (Textile)
5-15
Motor and Drive Basics
Medical Procedure Rooms
15
20
Packing Houses
2-15
Office Spaces
20
7
Full Load Current
Three Phase Motor
Pharmacies
15
Photo Studios
15
Physical Therapy
Watts
w
I=
Volts
E
Volts x Amperes x Eff
HP =
746
Amps =
1-1.5
2-10
2-5
Fan Laws
SP1  RPM1 
=

SP2  RPM2 
CFM1 RPM1
=
CFM2 RPM2
2
HP1  RPM1 
=

HP2  RPM2 
V Belt Length Formula
 ( D − d )2 
L = 2c + 1.57( D + d ) + 

 4c 
where
L = Pitch Length of Belt
c = Center Distance of Sheaves
D = Picth Diameter of Large Sheave
d = Pitch Diameter of Small Sheave
Recreation Rooms
2-8
20
Residences
2-5
HP
115V
200V
230V
460V
575V
10
Resturants
5-10
1/2
4
2.3
2
1
.8
15
20
Retail Stores
3-10
3/4
5.6
3.2
2.8
1.4
1.1
Resturant Dining Areas
20
70
Shops (General)
1
7.2
4.15
3.6
1.8
1.4
Retail Facilities
15
20
Theaters
3-8
Toilets
2-5
Transformer Rooms
1-5
Smoking Lounges
60
70
Sporting Spectator Areas
15
150
Supermarkets
15
8
Theaters
15
150
3-10
Turbine Rooms
2-6
Warehouses
2-10
Duct Design
Typical Design Velocities for HVAC Components
Circle Formulas
π d2
4
C = πd
A=
Intake Louvers
7000 CFM and Greater
Where:
A = Area
C = Circumference
d = diameter
Velocity (FPM)
400
Exhaust Louvers
5000 CFM and Greater
500
Filters - Pleated
Low Efficiency
350
Medium Efficiency
500
High Efficiency
500
HEPA
250
3
Full Load Current
Single Phase Motor
1 1/2
10.4
6
5.2
2.6
2.1
2
13.6
7.8
6.8
3.4
2.7
3
11
9.6
4.8
3.9
5
17.5
15.2
7.6
6.1
7 1/2
25
22
11
9
10
32
28
14
11
15
48
42
21
17
HP
115V
200V
230V
20
62
54
27
22
1/6
4.4
2.5
2.2
25
78
68
34
27
1/4
5.8
3.3
2.9
30
92
80
40
32
1/3
7.2
4.1
3.6
40
120
104
52
41
1/2
9.8
5.6
4.9
50
150
130
65
52
2300V
4000V
8.8
3/4
13.8
7.9
6.9
60
177
154
77
62
15.4
1
16
9.2
8
75
221
192
96
77
19.2
11
1 1/2
20
11.5
10
100
285
248
124
99
24.8
14.3
2
24
13.8
12
125
358
312
156
125
31.2
18
3
34
19.6
17
150
415
360
180
144
36
20.7
5
56
32.2
28
200
550
480
240
192
48
27.6
Over 200 HP
Approx. Amps/HP
2.75
2.4
1.2
.96
.24
.14
7 1/2
80
46
40
10
100
57.5
50
.02 .03 .04 .06 .08.1
.2
.3 .4
.6 .8 1
2
3 4
6 8 10
32
30
28
26
24
22
20
18
0
00
ity
12
loc
0
Ve
00
m
10 0 Fp
0
9000
80 0
0
75000
7 00
65 00
6000
55 0
0
50 0
0
45
00
40
00
36 0
0
3200
30 00
2800
2600
24 0
0
22
00
20
00
18 0
0
16
00
14
00
12
.01
100,000
80,000
60,000
40,000
0
30,000 8
0
20,000 7
r
ete
In.
ct
Du
m
Dia
60
55
10,000 50
8,000 5
4
6,000
40
4,000
6
3,000 3
32
2,000 30
28
26
4
1,000 2
800 22
0
600 2
18
400
4
300 1
14
12
CFM
10
9
8
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
By
4047.0
.4047
43560.0
4840.0
2.471 x 10-4
640.0
1.273
.8361
Multiply Length
centimeters
fathoms
feet
feet
inches
kilometers
meters
meters
meters
miles
miles
rods
yards
x
x
x
x
x
x
x
x
x
x
x
x
x
By
.3937
6.0
12.0
.3048
2.54
.6214
3.281
39.37
1.094
5280.0
1.609
5.5
.9144
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
7.854x10-7
.7854
2.471
1.076 x 105
.155
144.0
.0929
6.452
1.196
To Obtain
Square meters
Hectares
Square feet
Square yards
Square inches
Square mils
Acres
Square feet
Square inches
Square inches
Square meters
Square cm.
Square yards
Acres
Acres
Circular mils
Square meters
7
6
5
4
200 12
100
80
60
Multiply Area
acres
acres
acres
acres
circular mils
circular mils
hectares
hectares
square centimeters
square feet
square feet
square inches
square meters
square meters
square miles
square mils
square yards
3
10
9
8
2
Fp
7
ter
m
20
5
me
cit
6
lo
Ve
40
30
y
In.
00
18
00
16
00
14
00
12
00
10
0
90
0
80
0
.3 .4
/2
1-1
c
Du
70
0
60
0
.2
50
0
0
0
40
30
20
10 4
.01
.02 .03 .04 .06 .08 1
ia
tD
.6 .8 1
2
3 4
Friction in Inches of Water per 100 Feet
Friction of Air in Straight Duct
6
8 10
=
=
=
=
=
=
=
=
=
=
=
=
=
To Obtain
Inches
Feet
Inches
Meters
Centimeters
Miles
Feet
Inches
Yards
Feet
Kilometers
Yards
Meters
Visit Us
Welcome to Langendorf Supply Co., Inc
WAREHOUSE HOURS 7:30 - 4:30 CENTRAL TIME
BRYAN TALLEY AND LOU KRANUNG
314-291-4892 EXT 312
NEXTEL 314-486-5717 ID NUMBER 37156

Similar documents

2015/2016 stock catalog - Hahn Mason Air Systems, Inc

2015/2016 stock catalog - Hahn Mason Air Systems, Inc environmental air flow control. Cleanroom and hospital OR integrated ceiling diffuser systems Gas Fired Infrared Radiant Heaters - Dry Tube System Gas/Electric make-up air & DOAS units VAV Diffuser...

More information