Maxseal Solenoid Valves
Transcription
Maxseal Solenoid Valves
Maxseal Solenoid Valves Up to 4" Maxseal Technology from FCX Thompson Valves. An Industry Standard Evolved from an Original Concept. • Original, direct-acting design specified throughout industry for process control and related instrumentation. • Exacting standards in chemical, gas turbine, naval, nuclear power, offshore, petrochemical and pharmaceutical applications. • 40 year track record of effective safety in hazardous service duties. • 40 years experience in North Sea environments. • A worldwide market leader for proven performance and reliability. Approvals and Certification. Maxseal solenoid valves are designed for use in hazardous areas and conform to BASEEFA / SIRA and European CENELEC specifications. Factory Mutual Research Corporation Approved. Maxseal valves comply with the following EC directives and are therefore entitled to bear the CE mark. 89/392/EEC 89/336/EEC as amended by 92/31/EEC and 93/68/EEC 72/23/EEC as amended by 93/68/EEC ATEX Directive 94/9/EC PHOTOGRAPH COURTESY OF ALSTOM POWER UK LTD Machinery Directive Electromagnetic Compatibility Directive (EMCD) Low Voltage Directive (LVD) 2 We are here to help! When you've browsed this overview, talk to us about the best solution for your system. The Industry Standard Maxseal Solenoid Valve. Model Shown: ICO4S 1/4" Stainless Steel EEx d Valve. Ingress protection to IP66. Position feedback (larger models). Class “H” insulation. DC coils with suppression diodes. Low power direct acting lift. High-thrust return spring. Threaded or flanged process connections (larger models). 2/2, 3/2 and 5/2 port configurations. Low-friction poppet design. Seal/body options 0-207 bar (0-3000 psi) gases and liquids. Full flow capability. Manual and tamper-proof reset options. • Proven reliability of the original direct-acting solenoid valve design. • Certification and approvals for use in hazardous areas. • Choice of materials to suit process requirements. • Compact and lightweight unit. We are here to help! www.fcx-thompson-valves.com 3 The Power to Perform. FCX Thompson Valves is part of the FCX Flow Control division of Charles Baynes plc, a leading supplier of specialist flow control products with a network of global resources. PHOTOGRAPH COURTESY OF ALSTOM POWER UK LTD FCX Thompson Valves packaged and component solutions are specified worldwide for their high technical added value and fitness for purpose in exacting control and instrumentation applications. A Tradition of Integrity. Maxseal solenoid valves produced by FCX Thompson Valves consistently set rigorous standards for process management in the most demanding environments: aerospace, defense, gas turbine, mining, nuclear power, offshore and petrochemical industries. www.fcx-thompson-valves.c We are here to help! sales@fcx-thompson-valves.com +44 1202 697521 Safe, Reliable and Cost-Effective Solutions. Maxseal solenoid valves from FCX Thompson Valves are market leaders. In critical duties such as oil and gas, they perform on most offshore production platforms in the North Sea, as well as in all major onshore terminals. Gas t Absorption equipment Water treatment Absorption equipm Fuel systems Gas turbines, generators and compressors Air condit Pipeline shut-off Water treatment Fire safety and deluge systems Fire safety and delug Contents. Page Maxseal Technology from FCX Thompson Valves 2 Technical Information Hazardous area Model Connection size Operating pressure, bar (psi) Zone 0 ICO2S 1/4" Main valve Pilot valve Zone 1 ICO4D ICO4S ICO4D ICO4S SOV 1-2 1/4" NPT NPT 1/2" NPT 1/2" NPT 1/2" - 3/4" NPT 1/2" - 3/4" flanged 1" - 2" NPT 1" - 3" flanged 0 0 0 0 0 POICO4 1/4" NPT Dual shuttle valve 1/4" NPT POV 1/2" - 2" NPT - 4" flanged Main valve Pilot valve Main valve Pilot valve Main valve Pilot valve 1/4" SOV 3-6 Zones 1 and 2 1/2" - 20 20 20 20 20 (0 (0 (0 (0 (0 - 0 - 20 (0 - 290) 2 - 7 (29 - 101.5) 8 10 12 14 16 0 - 20 (0 - 290) 18 0 2 0 0 0 2 NPT 1" - 2" NPT 1" - 4" flanged 0 - 20 (0 - 290) 0 - 20 (0 - 290) As SOV 1-6, Zone 2 NPT As SOV 1-6, Main valve Pilot signal Main valve Pilot signal ICO4N SOV 1-6 Unclassified SOV 1-6 (weatherproof) AOV 1/4" AOV 1/2" - 2" NPT - 4" flanged 6 290) 290) 290) 290) 290) 1/4" Zone 2 1/2" com NPT - 20 10 10 10 20 10 Zone 2 0 - 20 2 - 10 0 - 20 2 - 10 (0 - 290) (29 - 145) (0 - 145) (0 - 145) (0 - 290) (29 - 145) 20 22 24 26 28 (0 - 290) (29 - 145) (0 - 290) (29 - 145) 28 30 32 Optional Valve Features Automatic Lever Manual Reset Lever Manual Override Automatic Latching Lever Tamperproof Manual Reset 34 34 34 34 34 Special Valve Features Indicating Switches High Temperature Spacer Horizontal Mounting 35 35 35 Hazardous Area Guidelines Intrinsic Safety Installation Guidelines Coding System 36 37 38 Valve Flow Characteristics 40 Valve Flow Performance Charts 1. Air Flow, ICO4 1/4", Low Pressure 2. Air Flow, ICO4 1/2", Low Pressure 3. Liquid Flow, ICO4 1/4", Low Pressure 4. Liquid Flow, ICO4 1/4", High Pressure 5. Flow Test, ICO4 1/4" 6. Flow Test, ICO4 1/2" 7. Flow Test, ICO4 1/2" 43 43 44 44 45 46 46 Conversion Chart 47 turbines, generators and compressors Pneumatic cylinders Pipeline shut-off Emergency shutdown Absorption Emergency shutdown systems Pipeline shut-off ment s Absorption equipment tioners and Air dryers conditioners and dryers Pneumatic cylinders Fuel systems ge systems Fuel systems Air conditioners and dryers Pneumatic cylinders Gas turbines, generators and compressors Hazardous Area Zone 0 Maxseal Instrument Changeover and Process Control Valve for Hazardous Areas EEx ia Model ICO2S 1/4" - 2" Certification Description II 1G SIRA / CENELEC approved EEx ia IIC T6 Ta (-40ºC to +64ºC) Complies with EN 50014:1997 (incl. amendments A1 and A2), EN 50020:1994 and EN 50284:1999 Complies with ATEX Directive 94/9/EC Complies to Electrical Safety Standard IEC 1010 Assessed compliant to Pressure Equipment Directive 97/23/EC FM approved to I.S. Class I Division 1 Groups A.B.C.D. A pilot operated solenoid valve certified for use with hazardous gases. 2-port, EO 3-port 5-port A C E A C B D B Standard Features Port thread (main body) Port configuration Operating pressure Main valve Pilot valve 1/4" NPT 0 - 20 bar(g) (0 - 290 psi) 2 - 7 bar(g) (29 - 101.5 psi) Pilot assisted Stainless steel BS EN 10088 Liquids and gases 2 - 7 bar (29 - 101.5 psi) clean and dry instrument air or inert gas Seat / Seal material High nitrile (Buna N) Operating voltage 24V DC; 0.5W at 20ºC (68ºF) through barrier M20 x 1.5 mm ISO (F) / NPT 1/4" 6 Port thread Paint finish Unpainted Coil housing material Stainless steel BS 3146 ANC.4 BFC.316 Weight 3-port version: 3 kg (6.6 lb) Cv value 0.8 (Kv 0.69) 1/4" 1/2" 3/2 Uni Valve material Conduit / Signal entry A B B Options Actuation method Media Main valve Pilot valve A 2-port, EC - 2" BSPP / BSPT - 2" NPT Port configuration 5/2 Uni; 2/2 EO; 2/2 EC Actuation method Autolatch, lever manual reset (LMR), lever manual override (LMO), tamperproof manual reset (see "Optional Valve Features") Valve material Brass BS EN 12163: 1998 Seat / Seal material Viton®, nylon 66 (high pressure seat only) Alternative materials available on request Conduit / Signal entry 1/2" CV value (main valve) 1/4" model 1/2" - 2" models NPT 0 - 50 bar(g) (0 - 725 psi) = 0.6 (Kv = 0.5) 0 - 103/207 bar(g) (0 - 1494/3000 psi) = 0.28 (Kv = 0.24) Please contact us Viton® is a registered trademark of DuPont Dow Elastomers LLC. Hazardous Area Zone 0 Maxseal Instrument Changeover and Process Control Valve for Hazardous Areas EEx ia ICO2S 1/4" - 2" Technical Specification Protection Ingress IP66 / X8. NEMA 4X Surge suppression diodes Response times (typical, dependent on coil size) Pull-in < 150 ms Drop-out < 80 ms Response times settings Pull-in: within 87.5% of nominal (factory set at less than 75% of nominal) Drop-out: normally 10-20% of nominal Operating pressure ranges (main valve) 1/4" model 0 - 20 bar(g) 0 - 50 bar(g) 0 - 103 bar(g) 0 - 207 bar(g) 1/2" - 2" models Please contact (0 (0 (0 (0 us - Dimensions in mm (inches) 290 psi) (standard) 725 psi) (option) 1494 psi) (option) 3000 psi) (option) A typical basic installation would comprise a 24V DC power supply, control switch or relay, and an EEx.ia 300Ω 28V barrier. (3/2 Uni 1/4" configuration illustrated) Pilot vent port 22.2 (0.87) ø 56 (2.20) 118 (4.65) 22.2 (0.87) 21 (0.83) 11 (0.43) 45 (1.77) Pilot inlet port 124.5 (4.90) 170 (6.69) 2 x M6 mounting studs 202 (7.95) 47 (1.85) M20 x 1.5 mm ISO conduit entry ø 58 (2.28) Port A Inlet Port B Outlet Port C Exhaust ø 50.8 (2) For your convenience, Operation and Maintenance instructions are included with each valve. 7 Hazardous Area Zone 1 Maxseal Instrument Changeover and Process Control Valve for Hazardous Areas EEx d Model ICO4D 1/4" Certification Description II 2G EECS (BASEEFA) / SIRA CENELEC approved EEx d IIC T6 (Ta = -60ºC to +40ºC) or EEx d IIC T4 (Ta = -60ºC to +90ºC) Complies with BS 5501: Part 5:1977, EN 50014:1977 (amendments 1 and 2) and EN 50018:1994 Complies with ATEX Directive 94/9/EC A direct-acting solenoid valve certified for hazardous area use as well as general air and gas purposes in the offshore and petrochemical industries. 2-port, EO 3-port 5-port A C E A C B D 2-port, EC B Standard Features Options Port thread 1/4" Port configuration NPT Port thread 1/4" 3/2 Uni Port configuration 5/2 Uni; 2/2 EO; 2/2 EC Operating pressure 0 - 20 bar(g) (0 - 290 psi) Actuation method Actuation method Automatic Valve material Stainless steel BS EN 10088 Seat / Seal material High nitrile (Buna N) Autolatch, lever manual reset (LMR), lever manual override (LMO), tamperproof manual reset (see "Optional Valve Features") Operating voltage 24V DC; 4.5W at 20ºC (68ºF) Valve material Brass BS EN 12163: 1998 Seat / Seal material Conduit / Signal entry M20 x 1.5 mm ISO (F) Paint finish Standard (green) 40 µm Viton®, nylon 66 (high pressure seat only) Alternative materials available on request Coil housing material Cast iron BS EN 1561: 1997 Operating voltages DC: 12, 24, 48, 110, 125, 240 AC: 24, 50, 110, 240, 440 Conduit / Signal entry 1/2" Paint Epoxy (light grey) 150 µm CV value 0 - 50 bar(g) (0 - 725 psi) = 0.6 (Kv = 0.5) 0 - 103/207 bar(g) (0 - 1494/3000 psi) = 0.28 (Kv = 0.24) Weight 3-port version: 5 kg (11 lb) Cv value 0.8 (Kv 0.69) BSPP; 1/4" BSPT NPT, 13.5 PG Viton® is a registered trademark of DuPont Dow Elastomers LLC. 8 Hazardous Area Zone 1 Maxseal Instrument Changeover and Process Control Valve for Hazardous Areas EEx d ICO4D 1/4" Technical Specification Protection Ingress IP65 - IP68 Surge suppression diodes Response times (typical, dependent on coil size) Pull-in < 150 ms Drop-out < 80 ms Response times settings Pull-in: within 87.5% of nominal (factory set at less than 75% of nominal) Drop-out: normally 10-20% of nominal Operating pressure ranges 0 0 0 0 - 20 bar(g) 50 bar(g) 103 bar(g) 207 bar(g) (0 (0 (0 (0 - 290 psi) (standard) 725 psi) (option) 1494 psi) (option) 3000 psi) (option) Dimensions in mm (inches) (3/2 Uni configuration illustrated) 55 (2.16) 57 (2.24) 52 (2.04) 54 (2.12) M20 x 1.5 mm ISO conduit entry 54 (2.12) 22 (0.86) 20 (0.78) 30 (1.18) ø 56 (2.20) 85 (3.34) 62 (2.44) 21.5 22.2 (0.85) (0.87) 11 (0.43) 150 (5.90) 192 (7.56) 2 x M8 mounting studs Port A Inlet Port B Outlet Port C Exhaust 50.8 (2) Remember that overhaul kits and replacement coil housing assemblies are available. 9 Hazardous Area Zone 1 Maxseal Instrument Changeover and Process Control Valve for Hazardous Areas EEx d Model ICO4S 1/4" Certification Description II 2G EECS (BASEEFA) / SIRA CENELEC approved EEx d IIC T6 (Ta = -60ºC to +48ºC) or EEx d IIC T4 (Ta = -60ºC to +90ºC) Complies with EN 50014:1997 (amendments 1 and 2) and EN 50018:1994 Complies with ATEX Directive 94/9/EC FM approved to Class I Division 1 Groups A. B. C. D A direct-acting solenoid valve certified for hazardous area use as well as general air and gas purposes in the offshore and petrochemical industries. 2-port, EO 3-port 5-port A C E A C B D B Standard Features Port thread 2-port, EC Options 1/4" NPT Port thread 1/4" BSPP; 1/4" BSPT Port configuration 3/2 Uni Port configuration 5/2 Uni; 2/2 EO; 2/2 EC Operating pressure 0 - 20 bar(g) (0 - 290 psi) Actuation method Autolatch, lever manual reset (LMR), lever manual override (LMO), tamperproof manual reset (see "Optional Valve Features") Actuation method Automatic Valve material Stainless steel BS EN 10088 Seat / Seal material High nitrile (Buna N) Operating voltage 24V DC; 4.5W at 20ºC (68ºF) Conduit / Signal entry M20 x 1.5 mm ISO (F) Paint finish Unpainted Coil housing material Stainless steel BS 3146 ANC.4 BFC.316 Weight 3-port version: 5 kg (11 lb) Cv value 0.8 (Kv 0.69) Valve material Brass BS EN 12163: 1998 Seat / Seal material Viton®, nylon 66 (high pressure seat only) Alternative materials available on request Operating voltages DC: 12, 24, 48, 110, 125, 240 AC: 24, 50, 110, 240, 440 Conduit / Signal entry 1/2" CV value 0 - 50 bar(g) (0 - 725 psi) = 0.6 (Kv = 0.5) 0 - 103/207 bar(g) (0 - 1494/3000 psi) = 0.28 (Kv = 0.24) NPT, 13.5 PG Viton® is a registered trademark of DuPont Dow Elastomers LLC. 10 Hazardous Area Zone 1 Maxseal Instrument Changeover and Process Control Valve for Hazardous Areas EEx d ICO4S 1/4" Technical Specification Protection Ingress IP65 / X8. NEMA 4X Surge suppression diodes Response times (typical, dependent on coil size) Pull-in < 150 ms Drop-out < 80 ms Response times settings Pull-in: within 87.5% of nominal (factory set at less than 75% of nominal) Drop-out: normally 10-20% of nominal Operating pressure ranges 0 0 0 0 - 20 bar(g) 50 bar(g) 103 bar(g) 207 bar(g) (0 (0 (0 (0 - 290 psi) (standard) 725 psi) (option) 1494 psi) (option) 3000 psi) (option) Dimensions in mm (inches) (3/2 Uni configuration illustrated) We recommend installing a strainer or filter as close as possible to valve inlet. While protecting seating areas from potential damage, this helps maintain air quality Talk to us about filtration! 11 Hazardous Area Zone 1 Maxseal Instrument Changeover and Process Control Valve for Hazardous Areas EEx d Model ICO4D 1/2" Certification Description II 2G EECS (BASEEFA) / SIRA CENELEC approved EEx d IIC T6 (Ta = -60ºC to +40ºC) or EEx d IIC T4 (Ta = -60ºC to +90ºC) Complies with BS 5501: Part 5:1977, EN 50014:1977 (amendments 1 and 2) and EN 50018:1994 Complies with ATEX Directive 94/9/EC A direct-acting solenoid valve certified for hazardous area use as well as general air and gas purposes in the offshore and petrochemical industries. 2-port, EO 3-port A C 2-port, EC B Standard Features Options Port thread 1/2" Port configuration NPT Port thread 1/2" BSPP; 1/2" BSPT 3/2 Uni Port configuration 2/2 EO; 2/2 EC Operating pressure 0 - 20 bar(g) (0 - 290 psi) Actuation method Actuation method Automatic Valve material Stainless steel BS EN 10088 Seat / Seal material High nitrile (Buna N) Autolatch, lever manual reset (LMR), lever manual override (LMO), tamperproof manual reset (see "Optional Valve Features") Operating voltage 24V DC; 15.2W at 20ºC (68ºF) Valve material Brass BS EN 12163: 1998 Seat / Seal material Conduit / Signal entry M20 x 1.5 mm ISO (F) Paint finish Standard (green) 40 µm Viton® Alternative materials available on request Coil housing material Cast iron BS EN 1561: 1997 Operating voltages DC: 12, 24, 48, 110, 125, 240 AC: 24, 50, 110, 240, 440 Weight 3-port version: 8 kg (17.6 lb) Conduit / Signal entry 1/2" Cv value 4.2 (Kv 3.61) Paint Epoxy (light grey) 150 µm CV value 0 - 50 bar(g) (0 - 725 psi) = 3.8 (Kv = 2.7) non-universal NPT, 13.5 PG Viton® is a registered trademark of DuPont Dow Elastomers LLC. 12 Hazardous Area Zone 1 Maxseal Instrument Changeover and Process Control Valve for Hazardous Areas EEx d ICO4D 1/2" Technical Specification Protection Ingress IP65 - IP68 Surge suppression diodes Response times (typical, dependent on coil size) Pull-in < 150 ms Drop-out < 80 ms Response times settings Pull-in: within 87.5% of nominal (factory set at less than 75% of nominal) Drop-out: normally 10-20% of nominal Operating pressure ranges 0 - 20 bar(g) 0 - 50 bar(g) (0 - 290 psi) (standard) (0 - 725 psi) non-universal (option) Dimensions in mm (inches) (3/2 Uni configuration illustrated) 54 (2.12) 22 (0.86) 57 (2.24) 20 (0.78) 36 (1.41) ø 76 (3.0) 140 (5.51) 117 (4.60) 44 (1.73) 22 (0.86) 205 (8.07) 247 (9.72) 30 (1.18) 55 (2.16) 52 (2.04) M20 x 1.5 mm ISO conduit entry 54 (2.12) 2 x M8 mounting studs Port A Inlet Port B Outlet Port C Exhaust 70 (2.76) For your convenience, Operation and Maintenance instructions are included with each valve. 13 Hazardous Area Zone 1 Maxseal Instrument Changeover and Process Control Valve for Hazardous Areas EEx d Model ICO4S 1/2" Certification Description II 2G EECS (BASEEFA) / SIRA CENELEC approved EEx d IIC T6 (Ta = -60ºC to +48ºC) or EEx d IIC T4 (Ta = -60ºC to +90ºC) Complies with EN 50014:1997 (amendments 1 and 2) and EN 50018:1994 Complies with ATEX Directive 94/9/EC FM approved to Class I Division 1 Groups A. B. C. D A direct-acting solenoid valve certified for hazardous area use as well as general air and gas purposes in the offshore and petrochemical industries. 2-port, EO 3-port A C 2-port, EC B Standard Features Port thread Options 1/2" NPT Port thread 1/2" BSPP; 1/2" BSPT Port configuration 3/2 Uni Port configuration 2/2 EO; 2/2 EC Operating pressure 0 - 20 bar(g) (0 - 290 psi) Actuation method Autolatch, lever manual reset (LMR), lever manual override (LMO), tamperproof manual reset (see "Optional Valve Features") Actuation method Automatic Valve material Stainless steel BS EN 10088 Seat / Seal material High nitrile (Buna N) Operating voltage 24V DC; 15.2W at 20ºC (68ºF) Conduit / Signal entry M20 x 1.5 mm ISO (F) Paint finish Unpainted Coil housing material Stainless steel BS 3146 ANC.4 BFC.316 Weight 3-port version: 8 kg (17.6 lb) Cv value 4.2 (Kv 3.61) Valve material Brass BS EN 12163: 1998 Seat / Seal material Viton® Alternative materials available on request Operating voltages DC: 12, 24, 48, 110, 125, 240 AC: 24, 50, 110, 240, 440 Conduit / Signal entry 1/2" CV value 0 - 50 bar(g) (0 - 725 psi) = 3.8 (Kv = 2.7) non-universal NPT, 13.5 PG Viton® is a registered trademark of DuPont Dow Elastomers LLC. 14 Hazardous Area Zone 1 Maxseal Instrument Changeover and Process Control Valve for Hazardous Areas EEx d ICO4S 1/2" Technical Specification Protection Ingress IP65 / X8. NEMA 4X Surge suppression diodes Response times (typical, dependent on coil size) Pull-in < 150 ms Drop-out < 80 ms Response times settings Pull-in: within 87.5% of nominal (factory set at less than 75% of nominal) Drop-out: normally 10-20% of nominal Operating pressure ranges 0 - 20 bar(g) 0 - 50 bar(g) (0 - 290 psi) (standard) (0 - 725 psi) non-universal (option) Dimensions in mm (inches) (3/2 Uni configuration illustrated) 41 (1.61) 41 (1.61) 22 (0.86) 20 (0.78) 30 (1.18) 55 (2.16) 59 (2.32) M20 x 1.5 mm ISO conduit entry 36 (1.41) ø 76 (3.0) 134 (5.27) 117 (4.60) 44 (1.73) 22 (0.86) 203 (7.99) 240 (9.45) 2 x M8 mounting studs Port A Inlet Port B Outlet Port C Exhaust 70 (2.76) Remember that overhaul kits and replacement coil housing assemblies are available. 15 Hazardous Area Zone 1 Maxseal Direct Solenoid-Operated Control Valve for Hazardous Areas EEx d Model SOV, Sizes 1 & 2 (1/2" - 3/4") Certification Description EECS (BASEEFA) / CENELEC approved EEx d IIC T6 or EEx d IIC T4 (Ta = 90ºC) Complies with EN 50014:1997 and EN 50018:1977 A direct-acting solenoid valve certified for hazardous area use as well as general air and gas purposes in the offshore and petrochemical industries. 2-port, EO 3-port 5-port A C E A C B D B Standard Features Options Port thread 1/2" Port configuration 3/2 Uni - 3/4" NPT Operating pressure 0 - 20 bar(g) (0 - 290 psi) Actuation method Port connections Female threaded Flanged 1/2" Automatic Port configuration 5/2 Uni; 2/2 EO; 2/2 EC Valve material Stainless steel BS EN 10088 Actuation method Seat / Seal material High nitrile (Buna N) Autolatch, lever manual reset (LMR), lever manual override (LMO), tamperproof manual reset (see "Optional Valve Features") Operating voltage Size 1 Size 2 24V DC; 18W at 20ºC (68ºF) 24V DC; 25W at 20ºC (68ºF) Conduit / Signal entry M20 x 1.5 mm ISO (F) Paint finish Standard (green) 40 µm Coil housing material Cast iron BS EN 1561: 1997 Weight (approx.) Cv value at 20 bar (290 psi) 1/2" model 3/4" model Valve material BSPP; 1/2" BSPT - 3/4" BS 10, BS 1560 or BS 4504 1/2" Brass BS EN 12163: 1998 Flanged/cast bodies available on request Seat / Seal material Viton®, nylon 66 (high pressure seat only) Alternative materials available on request 3-port version: 20 kg (44 lb) Operating voltages 3.2 (Kv 2.7) 6.8 (Kv 5.8) DC: 12, 24, 48, 110, 125, 240 AC: 24, 50, 110, 240, 440 Conduit / Signal entry 1/2" Paint Epoxy (light grey) 150 µm CV value 0 - 50 bar(g) (0 - 725 psi) + Please contact us Viton® is a registered trademark of DuPont Dow Elastomers LLC. 16 2-port, EC NPT, 13.5 PG Hazardous Area Zone 1 Maxseal Direct Solenoid-Operated Control Valve for Hazardous Areas EEx d SOV, Sizes 1 & 2 (1/2" - 3/4") Technical Specification Protection Ingress IP65 - IP68 Surge suppression diodes Response times Pull-in: please contact us Drop-out: please contact us Response times settings Pull-in: within 87.5% of nominal (factory set at less than 75% of nominal) Drop-out: normally 10-20% of nominal Operating pressure ranges 0 0 0 0 - 20 bar(g) 50 bar(g) 103 bar(g) 207 bar(g) (0 (0 (0 (0 - 290 psi) (standard) 725 psi) bar stock body (option) 1494 psi) bar stock body (option) 3000 psi) bar stock body (option) Dimensions in mm (inches) (Size 2 3/4" solenoid 3/2 Uni configuration illustrated) 72.5 (2.85) 70 (2.76) 22 (0.86) 80 (3.15) M20 x 1.5 mm ISO conduit entry 72.5 (2.85) 65 (2.56) 2 x M8 mounting studs ø 89 (3.50) 107 (4.21) 162 (6.38) 35 (1.38) 32 (1.26) 50.8 (2) 25.4 (1) 242 (9.52) 304 (12) 25.4 (1.0) Port A Inlet Port B Outlet Port C Exhaust 82.5 (3.25) We recommend installing a strainer or filter as close as possible to valve inlet. While protecting seating areas from potential damage, this helps maintain air quality Talk to us about filtration! 17 Hazardous Area Zone 1 Maxseal Direct Solenoid-Operated Control Valve for Hazardous Areas EEx d Model SOV, Sizes 3, 4, 5 & 6 (1" - 3") Certification Description EECS (BASEEFA) / CENELEC approved EEx d IIC T6 or EEx d IIC T4 (Ta = 90ºC) Complies with EN 50014:1997 and EN 50018:1977 A direct-acting solenoid valve certified for hazardous area use as well as general air and gas purposes in the offshore and petrochemical industries. Port thread 1" - 2" NPT Port configuration 3/2 Uni Operating pressure 0 - 20 bar(g) (0 - 290 psi) Actuation method Automatic Valve material Stainless steel BS EN 10088 Seat / Seal material High nitrile (Buna N) 24V 24V 24V 24V DC; DC; DC; DC; 40W 75W 100W 150W Conduit / Signal entry M20 x 1.5 mm ISO (F) Paint finish Standard (green) 40 µm Coil housing material Cast iron BS EN 1561: 1997 35 kg (77 lb) 58 kg (128 lb) 65 kg (144 lb) 115 kg (254 lb) Cv value at 20 bar (290 psi) 1" model 11/2" model 2" model 21/2" model 3" model 12.8 (Kv 11) 28 (Kv 24) 48 (Kv 41) 70 (Kv 60) 100 (Kv 86) A C B D B 2-port, EC Options Port connections Female threaded Flanged 1" - 2" BSPP / BSPT 1" - 3" BS 10, BS 1560 or BS 4504 Port configuration 5/2 Uni; 2/2 EO; 2/2 EC Actuation method Autolatch, lever manual reset (LMR), lever manual override (LMO), tamperproof manual reset (see "Optional Valve Features") Valve material Weight (approx.) Size 3 Size 4 Size 5 Size 6 Viton® is a registered trademark of DuPont Dow Elastomers LLC. 18 A C E 2-port, EO Standard Features Operating voltage at 20ºC (68ºF) Size 3 Size 4 Size 5 Size 6 3-port 5-port Brass BS EN 12163: 1998 Flanged/cast bodies available on request Seat / Seal material Viton®, nylon 66 (high pressure seat only) Alternative materials available on request Operating voltages DC: 12, 24, 48, 110, 125, 240 AC: 24, 50, 110, 240, 440 Conduit / Signal entry 1/2" Paint Epoxy (light grey) 150 µm CV value 50 bar(g) (725 psi) + Please contact us NPT, 13.5 PG Hazardous Area Zone 1 Maxseal Direct Solenoid-Operated Control Valve for Hazardous Areas EEx d SOV, Sizes 3, 4, 5 & 6 (1" - 3") Technical Specification Protection Ingress IP65 - IP68 Surge suppression diodes Response times Pull-in: please contact us Drop-out: please contact us Response times settings Pull-in: within 87.5% of nominal (factory set at less than 75% of nominal) Drop-out: normally 10-20% of nominal Operating pressure ranges 0 0 0 0 - 20 bar(g) 50 bar(g) 103 bar(g) 207 bar(g) (0 (0 (0 (0 - 290 psi) (standard) 725 psi) bar stock body (option) 1494 psi) bar stock body (option) 3000 psi) bar stock body (option) Dimensions in mm (inches) (Size 3 1" solenoid 3/2 Uni configuration illustrated. Double conduit thread for switches) 102 (4.0) 2 holes M20 x 1.5 conduit thread ø 189 (7.44) 90 (3.54) 15 (0.59) 85.7 (3.37) 60.3 31.7 9.5 Port B Outlet (2.0) (0.375) (1.25) 50.8 Port A Inlet ø 89 (3.50) 30 (1.18) 15 (0.59) 22 (0.86) 60 (2.36) 85 (3.34) 25 (0.98) 59 (2.32) 250 (9.84) (1.57) 2 off M8 x 1.25 mm mounting studs (2.37) 403 (15.86) 157.5 (6.20) 40 50 (1.96) Port C Exhaust ø 82.5 (3.24) Remember that overhaul kits and replacement coil housing assemblies are available. 19 Hazardous Area Zones 1 and 2 Maxseal Solenoid/Pilot-Operated Valve for Hazardous Areas EEx d, Ex N Model POICO4 1/4" Certification Description Pilot operated valve optionally supplied with ICO4S, ICO4D or ICO4N. Refer to the relevant valves for certification data. A pilot-operated valve certified for hazardous area use as well as general liquid and gas purposes in the offshore and petrochemical industries. A B Standard Features B A C C A B D 2-port, EC A C A C E 2-port, EO A C 3-port A C 5-port A B Options Port thread 1/4" NPT Port configuration 3/2 Uni Operating pressure Main valve Pilot valve 0 - 20 bar(g) (0 - 290 psi) 2 - 10 bar(g) (29 - 145 psi) Port thread (pilot body) 1/4" BSPP; 1/4" BSPT Port configuration 5/2 Uni; 2/2 EO; 2/2 EC Valve material Brass BS EN 12163: 1998 Seat / Seal material Viton®, nylon 66 (high pressure seat only) Alternative materials available on request Operating voltages DC: 12, 24, 48, 110, 125, 240 AC: 24, 50, 110, 240, 440 Actuation method Solenoid-operated, external pilot liquid/gas assisted Valve material Stainless steel BS EN 10088 Seat / Seal material High nitrile (Buna N) Conduit / Signal entry 1/2" Operating voltage 24V DC; 4.5W (ICO4D/S) at 20ºC (68ºF) Paint Epoxy (light grey) 150 µm CV value 0 - 50 bar(g) (0 - 725 psi) = 0.6 (Kv = 0.5) 0 - 103/207 bar(g) (0 - 1494/3000 psi) = 0.28 (Kv = 0.24) Conduit / Signal entry M20 x 1.5 mm ISO (F) Paint finish Standard (green) 40 µm Coil housing material ICO4D and ICO4N ICO4S Cast iron BS EN 1561:1997 Stainless steel BS 3146 ANC.4 BFC.316 Weight 3-port version: 5 kg (11 lb) Cv value 0.8 (Kv 0.69) NPT, 13.5 PG Viton® is a registered trademark of DuPont Dow Elastomers LLC. 20 Hazardous Area Zones 1 and 2 Maxseal Solenoid/Pilot-Operated Valve for Hazardous Areas EEx d, Ex N POICO4 1/4" Technical Specification Protection Ingress IP65 / IP68 Surge suppression diodes Response times (typical, dependent on coil size) Pull-in < 150 ms Drop-out < 80 ms Response times settings Pull-in: within 87.5% of nominal (factory set at less than 75% of nominal) Drop-out: normally 10-20% of nominal Operating pressure ranges Main valve 0 - 20 bar(g) Up to 207 bar(g) 0 - 20 bar(g) 2 - 10 bar(g) Pilot signal (0 - 290 psi) (3000 psi) (0 - 290 psi) (29 -145 psi) 2/2 and 3/2 ports 2/2 and 3/2 ports 5/2 port 2/2, 3/2 and 5/2 ports Dimensions in mm (inches) (ICO4N 3/2 Uni configuration illustrated) ø 82.6 (3.25) 4 6 (1.81) 4 8 (1.88) t el n I A t r o P t el t u O B t r o P tsu ah x E C t r o P 22 (0.86) 2 off M8 x 1.25 mm )1 )75. 11 (0.4 3) Pilot inlet 2 Pilot exhaust )0.1( ) 2 - 10 bar(g) (29 - 145 psi) 4.5 2 .1( 23 5. )7 3. 3 ( 4 8 3 4.0( 11 )0 69( 761 ) 2 .4( 701 2 )0.1( 4.5 y r tn e tiudno c O SI m m 5.1 x 0 2 M mounting studs (2 positions) 6 8 .0( 22 8 .0( 2. 2 2 )7 50. 8 (2.0) 101 ( 3.97) 22.2 87) (0. 145 (5.70) Remember that overhaul kits and replacement coil housing assemblies are available. 21 Hazardous Area Zones 1 and 2 Maxseal Dual Shuttle Valve for Hazardous Areas EEx d, Ex N Dual Shuttle Valve 1/4" - 1/2" Certification Description Dual shuttle valve optionally supplied with ICO4S, ICO4D or ICO4N. Refer to the relevant valves for certification data. A valve certified for hazardous area use as well as general liquid and gas purposes in the offshore and petrochemical industries. 5-port 2 4 3-port 3 2 3 5 1 1 Standard Features Options Port thread Solenoid valve Shuttle valve (female) 1/4" Port configuration 3/2 Operating pressure Main valve Pilot valve 0 - 10 bar(g) (0 - 145 psi) 2 - 10 bar(g) (29 - 145 psi) NPT 1/4" NPT Port thread Solenoid valve Shuttle valve (female) 1/4" BSPP; 1/4" BSPT - 1/2" BSPP; 1/4" - 1/2" BSPT; 1/2" NPT 1/4" Port configuration 5/2 Valve material Brass BS EN 12163: 1998 Seat / Seal material Viton® Alternative materials available on request Operating voltages (solenoid) DC: 12, 24, 48, 110, 125, 240 AC: 24, 50, 110, 240, 440 Actuation method Solenoid-operated, internal pilot gas assisted Valve material Stainless steel BS EN 10088 Seat / Seal material High nitrile (Buna N) Conduit / Signal entry 1/2" Operating voltage 24V DC; 4.5W (ICO4D/S) at 20ºC (68ºF) Paint Epoxy (light grey) 150 µm CV value at 10 bar (145 psi) 1/2" model 3.2 (Kv 2.7) Conduit / Signal entry M20 x 1.5 mm ISO (F) Paint finish Standard (green) 40 µm Coil housing material ICO4D and ICO4N ICO4S NPT, 13.5 PG Cast iron BS EN 1561:1997 Stainless steel BS 3146 ANC.4 BFC.316 Weight Please contact us Cv value at 10 bar (145 psi) 1/4" model 0.8 (Kv 0.69) Viton® is a registered trademark of DuPont Dow Elastomers LLC. 22 Hazardous Area Zones 1 and 2 Maxseal Dual Shuttle Valve for Hazardous Areas EEx d, Ex N Dual Shuttle Valve 1/4" - 1/2" Technical Specification Protection (solenoid) Ingress IP65 / IP68 Surge suppression diodes Response times (typical, dependent on coil size) Pull-in: Please contact us Drop-out: Please contact us Response times settings Pull-in: within 87.5% of nominal (factory set at less than 75% of nominal) Drop-out: normally 10-20% of nominal Dimensions in mm (inches) (5/2 1/4" configuration illustrated) 183 (7.2) 2 x M8 mounting studs 2 positions 27.2 (1.07) 55 (2.16) 2 1 54.4 (2.14) 59 (2.32) 27.3 (1.07) 234 (9.21) 21.5 (0.87) 86 (3.38) 20 (0.78) 51(2.0) 58 (2.99) 5 89.4 (3.51) M20 x 1.5 mm ISO conduit entry Exhaust port 116 (4.56) 158 (6.22) ø 80 (3.14) 186 (7.32) 4 3 We recommend installing a strainer or filter as close as possible to valve inlet. While protecting seating areas from potential damage, this helps maintain air quality Talk to us about filtration! 23 Hazardous Area Zones 1 and 2 Maxseal Solenoid/Pilot-Operated Valve for Hazardous Areas EEx d, Ex N Model POV 1/2" - 4" A pilot-operated valve certified for hazardous area use as well as general liquid and gas purposes in the offshore and petrochemical industries. A C E 1/2" Port configuration 1/2" - 4" 1/2" - 3" 1/2" - 2" 2/2 EO, 2/2 EC 3/2 5/2 Operating pressure Main valve Pilot valve 0 - 20 bar(g) (0 - 290 psi) 2 - 10 bar(g) (29 - 145 psi) C A B D 2-port, EC B A C Port thread 3-port A C 2-port, EO Standard Features Actuation method 5-port A C Description Pilot operated valve optionally supplied with ICO4S, ICO4D or ICO4N. Refer to the relevant valves for certification data. A C Certification - 2" NPT Solenoid-operated, external pilot liquid/gas assisted Valve material Stainless steel BS EN 10088 Seat / Seal material High nitrile (Buna N) Operating voltage 24V DC; 4.5W (ICO4D/S) at 20ºC (68ºF) Conduit / Signal entry M20 x 1.5 mm ISO (F) Paint finish A B A B Options Port thread (pilot body) 1/4" BSPP; 1/4" BSPT Port connections Female threaded 1/2" Flanged 1/2" - 2" BSPP / BSPT - 4" BS 10, BS 1504 or BS 4504 Valve material Brass BS EN 12163: 1998 Seat / Seal material Viton®, nylon 66 (high pressure seat only) Alternative materials available on request Standard (green) 40 µm Operating voltages Cast iron BS EN 1561:1997 Stainless steel BS 3146 ANC.4 BFC.316 DC: 12, 24, 48, 110, 125, 240 AC: 24, 50, 110, 240, 440 Conduit / Signal entry 1/2" Paint Epoxy (light grey) 150 µm Weight Please contact us CV value Cv value at 20 bar (290 psi) 1/2" model 3/4" model 1" model 11/2" model 2" model 3" model 4" model 3.2 (Kv 2.7) 6.8 (Kv 5.8) 12.8 (Kv 11) 28 (Kv 24) 48 (Kv 41) 100 (Kv 86) 165 (Kv 142) 0 - 50 bar(g) (0 - 725 psi) 0 - 103/207 bar(g) (0 - 1494/3000 psi) Please contact us Coil housing material ICO4D and ICO4N ICO4S NPT, 13.5 PG Viton® is a registered trademark of DuPont Dow Elastomers LLC. 24 Hazardous Area Zones 1 and 2 Maxseal Solenoid / Pilot-Operated Valve for Hazardous Areas EEx d, Ex N POV 1/2" - 4" Technical Specification Protection Ingress IP65 / IP68 Surge suppression diodes Response times Pull-in: please contact us Drop-out: please contact us Response times settings Pull-in: within 87.5% of nominal (factory set at less than 75% of nominal) Drop-out: normally 10-20% of nominal Operating pressure ranges Main valve Pilot signal 0 - 10 bar(g) (0 - 145 psi) 0 - 20 bar(g) (0 - 290 psi) 0 - 50 bar(g) (0 - 725 psi) 0 - 103 bar(g) (0 - 1494 psi) 0 - 138 bar(g) (0 - 2001 psi) 0 - 207 bar(g) (0 - 3000 psi) 2 - 10 bar(g) (29-145 psi) 2/2 port 1/2" - 4" 3/2 port 1/2" - 3" 5/2 port 1/2" - 2" 2/2 port 1/2" - 4" 3/2 port 1/2" - 3" 5/2 port 1/2" - 2" 2/2 port 1/2" - 2" 3/2 port 1/2" to 11/2" 2/2 port 1/2" to 11/2" 3/2 port 1/2" to 1" 2/2 port 1/2" to 11/2" 3/2 port 1/2" - 1" 2/2 port 1/2" to 11/2" 3/2 port 1/2" - 1" 2/2, 3/2 and 5/2 ports (option) (option) (option) (standard) (standard) (standard) (option) (option) (option) (option) (option) (option) (option) (option) Dimensions in mm (inches) (3/2 Uni 3/4" configuration illustrated) 52 (2.05) 54 (2.12) 54 (2.12) 1/4" 76 (3.0) 210 (8.26) Port A Inlet Port B Outlet Port C Exhaust 118 (4.65) 45 (1.7) 50.8 (2.0) Port A Inlet (1.0) Port C Vent 25.4 2 off M10 x 1.5 mm mounting studs 63.5 (2.5) 22.2 (0.87) 160 (6.30) NPT op. air inlet 2 - 10 bar(g) (29 - 145 psi) 11 (0.43) Conduit entry M20 x 1.5 mm ISO 161 (6.33) 89 (3.5) 31.75 (1.25) We recommend installing a strainer or filter as close as possible to valve inlet. While protecting seating areas from potential damage, this helps maintain air quality Talk to us about filtration! 25 Hazardous Area Zone 2 Maxseal Instrument Changeover and Process Control Valve for Hazardous Areas Ex N Model ICO4N 1/4" Certification Description EECS (BASEEFA) approved Ex N IIC T6 Ex N IIC T4 (Tamb = 90ºC) Complies with BS 6941: 1988 A direct-acting solenoid valve certified for hazardous area use as well as general air and gas purposes in the offshore and petrochemical industries. 3-port 2-port, EO A C 2-port, EC B Standard Features Port thread Options 1/4" NPT Port thread 1/4" BSPP; 1/4" BSPT Port configuration 3/2 Uni Port configuration 2/2 EO; 2/2 EC Operating pressure 0 - 20 bar(g) (0 - 290 psi) Actuation method Actuation method Automatic Valve material Brass BS EN 12163: 1998 Autolatch, lever manual reset (LMR), lever manual override (LMO), tamperproof manual reset (see "Optional Valve Features") Seat / Seal material High nitrile (Buna N) Operating voltage 24V DC; 7.8W at 20ºC (68ºF) Valve material Stainless steel BS EN 10088 Conduit / Signal entry M20 x 1.5 mm ISO (F) Seat / Seal material Paint finish Standard (green) 40 µm Viton®, Alternative materials available on request Coil housing material Cast iron BS EN 1561: 1997 Operating voltages Weight 3-port version: 3.5 kg (7.7 lb) DC: 12, 24, 50, 110, 125, 240 AC: 24, 50, 110, 240, 440 Cv value 0.8 (Kv 0.69) Conduit / Signal entry 1/2" Paint Epoxy (light grey) 150 µm CV value 0 - 50 bar(g) (0 - 725 psi) = 0.6 (Kv = 0.5) NPT, 13.5 PG Viton® is a registered trademark of DuPont Dow Elastomers LLC. 26 Hazardous Area Zone 2 Maxseal Instrument Changeover and Process Control Valve for Hazardous Areas Ex N ICO4N 1/4" Technical Specification Protection Ingress IP65 - IP68 Surge suppression diodes Response times (typical, dependent on coil size) Pull-in < 150 ms Drop-out < 80 ms Response times settings Pull-in: within 87.5% of nominal (factory set at less than 75% of nominal) Drop-out: normally 10-20% of nominal Operating pressure ranges 0 - 20 bar(g) 0 - 50 bar(g) (0 - 290 psi) (standard) (0 - 725 psi) (option) Dimensions in mm (inches) (3/2 Uni configuration illustrated) 22 (0.86) 48 (1.88) M20 x 1.5 mm ISO conduit entry ø 82.6 (3.25) 46 (1.81) ø 56 (2.20) 164 (6.45) 140 (5.5) 21.5 22.2 (0.85) (0.87) 11 (0.43) 62 (2.44) 84 (3.30) 25.4 (1.0) 2 x M8 mounting studs (inline) Port A Inlet Port B Outlet Port C Exhaust 50.8 (2) Remember that overhaul kits and replacement coil housing assemblies are available. 27 Hazardous Area Zone 2 Maxseal Direct Solenoid-Operated Control Valve for Hazardous Areas Ex es Model SOV, Sizes 1, 2, 3, 4, 5 & 6 (1" - 4") Certification Description EECS (BASEEFA) approved Ex es II T6 or Ex es II T4 (ambient = 85ºC) Complies with BS 5501: Part 6:1977 A direct-acting solenoid valve certified for hazardous area use as well as general air and gas purposes in the offshore and petrochemical industries. Standard Features 28 A C E 1" - 2" NPT Port configuration 3/2 Uni Operating pressure 0 - 20 bar(g) (0 - 290 psi) Actuation method Automatic Valve material Stainless steel BS EN 10088 Seat / Seal material High nitrile (Buna N) 24V 24V 24V 24V 24V 24V DC; DC; DC; DC; DC; DC; 18W 25W 40W 75W 100W 150W Conduit / Signal entry M20 x 1.5 mm ISO (F) Paint finish Standard (green) 40 µm Coil housing material Cast iron BS EN 1561: 1997 Weight (approx.) Size 1 Size 2 Size 3 Size 4 Size 5 Size 6 20 kg (44 Ib) 30 kg (66 Ib) 35 kg (77 lb) 58 kg (128 lb) 65 kg (144 lb) 115 kg (254 lb) Cv value at 20 bar (290 psi) 1" model 11/2" model 2" model 21/2" model 3" model 4" model 12.8 (Kv 11) 28 (Kv 24) 48 (Kv 41) 70 (Kv 60) 100 (Kv 86) 165 (Kv 142) A C B D 2-port, EO Port thread Operating voltage at 20ºC (68ºF) Size 1 Size 2 Size 3 Size 4 Size 5 Size 6 3-port 5-port B 2-port, EC Options Port connections Female threaded Flanged 1" - 2" BSPP / BSPT 1" - 4" BS 10, BS 1560 or BS 4504 Port configuration 5/2 Uni; 2/2 EO; 2/2 EC Actuation method Autolatch, lever manual reset (LMR), lever manual override (LMO), tamperproof manual reset (see "Optional Valve Features") Valve material Brass BS EN 12163: 1998 Flanged/cast bodies available on request Seat / Seal material Viton®, nylon 66 (high pressure seat only) Alternative materials available on request Operating voltages DC: 12, 24, 48, 110, 125, 240 AC: 24, 50, 110, 240, 440 Conduit / Signal entry 1/2" Paint Epoxy (light grey) 150 µm CV value 50 bar(g) (725 psi) + Please contact us NPT, 13.5 PG Hazardous Area Zone 2 Maxseal Direct Solenoid-Operated Control Valve for Hazardous Areas Ex es SOV, Sizes 1, 2, 3, 4, 5 & 6 (1" - 4") Technical Specification Protection Ingress IP65 - IP68 Surge suppression diodes Response times (typical, dependent on coil size) Pull-in: Please contact us Drop-out: Please contact us Response times settings Pull-in: within 87.5% of nominal (factory set at less than 75% of nominal) Drop-out: normally 10-20% of nominal Operating pressure ranges 0 0 0 0 - 20 bar(g) 50 bar(g) 103 bar(g) 207 bar(g) (0 (0 (0 (0 - 290 psi) (standard) 725 psi) bar stock body (option) 1494 psi) bar stock body (option) 3000 psi) bar stock body (option) Dimensions in mm (inches) M20 x 1.5 mm ISO conduit thread (Size 2 3/4" solenoid 3/2 Uni configuration illustrated) 130 (5.1) 80 (3.14) 12.7 (0.5) 25.4 (1.0) Port B Outlet 135 (5.31) 63.5 (2.5) Port A Inlet 50.8 (2.0) 130 (5.1) 38.1 (1.5) 64.6 (2.54) 318.5 (12.5) 22 (0.86) 35 66 (2.6) (1.37) 189 (7.4) 2 off M8 x 1.25 mm mounting studs Port C Exhaust 41.24 (1.6) 82.55 (3.25) Viton® is a registered trademark of DuPont Dow Elastomers LLC. ø 89 (3.5) We recommend installing a strainer or filter as close as possible to valve inlet. While protecting seating areas from potential damage, this helps maintain air quality Talk to us about filtration! 29 Unclassified Maxseal Air Operated Valve Model AOV 1/4" Description A general purpose direct-acting valve for liquid and gas management in industrial applications. 5-port 2-port, EO 3-port A C E A C B D A B Standard Features 2-port, EC A B B Options Port thread 1/4" NPT Port configuration 3/2 Uni Operating pressure Main valve Pilot signal 0 - 20 bar(g) (0 - 290 psi) 2 - 10 bar(g) (29 - 145 psi) Actuation method Liquid/gas operated Valve material Port thread 1/4" Port configuration 5/2, 2/2 EO; 2/2 EC Valve material Stainless steel BS EN 10088 Seat / Seal material Brass BS EN 12163: 1998 Viton® Alternative materials available on request Paint Epoxy (light grey) 150 µm Seat / Seal material High nitrile (Buna N) CV value Paint finish Standard (green) 40 µm 0 - 50 bar(g) (0 - 725 psi) = 0.6 (Kv = 0.5) 0 - 103/207 bar(g) (0- 1494/3000 psi) = 0.28 (kv = 0.24) Weight 3-port version: 2 kg (4.4 lb) Cv value 0.8 (Kv 0.69) BSPP; 1/4" BSPT Viton® is a registered trademark of DuPont Dow Elastomers LLC. 30 Unclassified Maxseal Air Operated Valve AOV 1/4" Technical Specification Response times 60 - 100 ms Operating pressure ranges Main valve 0 - 20 bar(g) Up to 207 bar(g) 0 - 20 bar(g) 2 - 10 bar(g) Pilot signal (0 - 290 psi) (3000 psi) (0 - 290 psi) (29 - 145 psi) 2/2 and 3/2 ports 2/2 and 3/2 ports 5/2 port 2/2, 3/2 and 5/2 ports Dimensions in mm (inches) (3/2 Uni configuration illustrated) 58 (2.28) 58 (2.28) Note: Housing size may vary with different pressure ratings 11 (0.43) 62 (2.44) 22.2 21.5 56 (2.20) (0.87) Port A Inlet Port B Outlet Port C Exhaust (0.85) 115 (4.52) 2 x M8 mounting studs 50.8 (2) For your convenience, Operation and Maintenance instructions are included with each valve. 31 Unclassified Maxseal Air Operated Valve Model AOV 1/2" - 4" Description A general purpose direct-acting valve for liquid and gas management in industrial applications. 5-port 2-port, EO 3-port A C E A C B D A B Standard Features 2-port, EC A B B Options Port thread 1/2" - 2" NPT Port configuration 1/2" - 4" 1/2" - 3" 1/2" - 2" 2/2 EO, 2/2 EC 3/2 5/2 Operating pressure Main valve Pilot signal 0 - 20 bar(g) (0 - 290 psi) 2 - 10 bar(g) (29 - 145 psi) Actuation method Air operated, external pilot liquid/gas assisted Valve material Brass BS EN 12163: 1998 Seat / Seal material High nitrile (Buna N) Paint finish Standard (green) 40 µm Weight Please contact us Cv value Please contact us Port thread 1/2" Port connections Female threaded Flanged 1/2" BSPP; 1/2" BSPT - 2" BSPP / BSPT - 4" BS 10, BS 1504 or BS 4504 1/2" Valve material Stainless steel BS EN 10088 Seat / Seal material Viton® Alternative materials available on request Paint Epoxy (light grey) 150 µm CV value Please contact us Viton® is a registered trademark of DuPont Dow Elastomers LLC. 32 Unclassified Maxseal Air Operated Valve AOV 1/2" - 4" Technical Specification Response times 60 - 100 ms Operating pressure ranges Main valve 0 - 10 bar(g) (0 - 145 psi) 0 - 20 bar(g) (0 - 290 psi) 0 - 50 bar(g) (0 - 725 psi) 0 - 103 bar(g) (0 - 1494 psi) 0 - 138 bar(g) (0 - 2001 psi) 0 - 207 bar(g) (0 - 3000 psi) 2 - 10 bar(g) (29-145 psi) Pilot signal 2/2 port 1/2" - 4" 3/2 port 1/2" - 3" 5/2 port 1/2" - 2" 2/2 port 1/2" - 4" 3/2 port 1/2" - 3" 5/2 port 1/2" - 2" 2/2 port 1/2" to 2" 3/2 port 1/2" to 11/2" 2/2 port 1/2" to 11/2" 3/2 port 1/2" to 1" 2/2 port 1/2" - 11/2" 3/2 port 1/2" to 1" 2/2 port 1/2" - 11/2" 3/2 port 1/2" - 1" 2/2, 3/2 and 5/2 ports (option) (option) (option) (standard) (standard) (standard) (option) (option) (option) (option) (option) (option) (option) (option) Dimensions in mm (inches) (2/2 EO 4" configuration illustrated) 20 3 (8.0) I nlet - pilot )5 7. 6 ( 5.1 7 1 )5 )0. 7 .21( 4 2 3 2 4 ( 6 .101 ø )52.8( 01 Closed Open 1 63.5 (6.43) 327 (12.875) For your convenience, Operation and Maintenance instructions are included with each valve. 33 Maxseal Solenoid Valves. Optional Valve Features. Automatic Latching Lever. Automatic (Standard). An electrical and/or air/gas supply energizes the valve, opening, closing or changing over valve ports, depending on model and porting configuration. When the valve is de-energized, it is spring-returned to its original position. When the solenoid is energized, the lever (standard) drops and latches the valve in the energized position. On loss of electrical supply, it remains latched until manually unlatched. Lever in reset position, i.e. valve de-energized to close Valve energized "open" when lever is in position shown Lever Manual Reset. After the valve operator is energized, the manual reset lever (or button) must be operated to move the valve to the energized position. When the valve is de-energized, it is spring-returned to its original position. Lever option: ICO4 and SOV. Button option: ICO2 and ICO4. Tamperproof Manual Reset. Models ICO2 and ICO4 3-port only. • When de-energized and with air on inlet port (A), • • • • Lever Manual Override. A jackscrew or lever (as shown) fitted to the base of the valve moves it to the energized or de-energized position without electrical power. 34 • the valve will not change-over, even when the reset button is pressed. When the coil is energized and the reset button pressed, the reset button lifts the spool assembly into the magnetic field of the coil, thereby holding the spool assembly in the energized position. No air will flow through the valve until the reset button is released. In the energized position, air flows from inlet port (A), via the “gallery drilling”, through the valve body and out through outlet port (B). At this point, exhaust port (C) is isolated. When the coil is de-energized, the spool assembly is spring-returned to the Port B de-energized position, Outlet Port C isolating inlet port (A) Exhaust and venting air from outlet port (B) to exhaust port (C). Port A If the push button is Inlet held, jammed or wire-locked in the depressed position, the air inlet supply remains isolated. Special Valve Features. Indicating Switches. High Temperature Spacer. Micro-switches, available on models SOV, AOV and POV only, indicate valve open and closed positions (2 x spdt standard). They can be fitted inside the coil housing (SOV) or to the base of the main valve (AOV and POV), and are electrically certified for the hazardous area required. Available on models ICO4 and SOV direct-acting solenoid valves only, high-temperature spacers are fitted between coil housing and valve assembly where media temperature exceeds 80ºC (176ºF). This feature dissipates heat away from the coil housing, preventing overheating of the coil itself. 1 2 3 4 5 6 7 8 9 10 11 12 Horizontal Mounting. For SOV direct-acting solenoid valves only, this feature is used on valves requiring the coil housing to be installed horizontally. It prevents excessive wear of dynamic seals within the valve body. We are here to help! Remember that complete spares kits are available. 35 Intrinsic Safety. This type of protection is based on the minimum energy needed to ignite a hazardous atmosphere. The risk of ignition can be avoided by designing the whole circuit in such a way that this energy is never available, either under normal operating conditions or under specific fault conditions. Typical Intrinsically Safe Circuit. Hazardous area Unlike other types of protection which apply to single electrical devices, “intrinsic safety” applies to the whole electrical circuit. Intrinsic safety implies: An intrinsically safe electrical device such as a solenoid valve must be installed together with a safety device which limits the available power (energy) to specific values. • limiting peak current and voltage at open circuit conditions, • limiting thermal and electrical energy storage. Safe area Supply via certified energy limiting device PHOTOGRAPH COURTESY OF SHELL 36 Hazardous Area Installation Guidelines. A simplified appreciation of hazardous area types and risk levels involved. The ultimate decision as to what constitutes a hazardous area (or zone) rests with the company chemist, usually in consultation with health and safety executives or an authorizing body. The role of the instrument or 1 design engineer is to ensure that emergency shutdown apparatus (ESD), e.g. Maxseal solenoid valves, complies with operating speed and zoning requirements. International Electrotechnical Commission 2 Most countries or trade areas have their own certifying authorities. Hazardous area installation standards in force in the EU are written by CENELEC1/IEC2. They can be certified by any recognized authorizing body, such as BASEEFA in the UK, and enjoy wide global acceptance, except in the USA and dollar areas where American standards prevail. European Committee for Electrotechnical Standards. Current CENELEC/IEC Hazardous Area Classification. An open area of plant or factory is considered hazardous when a fire or explosion may result from specific potential conditions. Three zones are defined: Zone 0 (Category 1 from 2003 as per the ATEX directive) “An area in which a hazardous or gas/air mixture is continuously present or present for long periods.” Zone 1 (Category 2 from 2003 as per the ATEX directive) “An area in which a hazardous gas/air mixture is likely to occur in normal operation.” Zone 2 (Category 3 from 2003 as per the ATEX directive) “An area where a hazardous gas/air mixture is unlikely to occur under normal operation, but if it occurred it would only be for a short duration.” Both the risk level and zoning definition are affected by ventilation, quantity and type of gas (heavier/lighter than air), as well as the need for a heat source to prompt ignition. 37 Hazardous Area Coding System. Solenoids should be selected according to the standard identification code for hazardous area equipment. E Exd IIC T6 CENELEC approved Type of protection e.g. “flameproof” Gas group e.g. “group II for hydrogen” See paragraph 1 See paragraph 2 Surface temperature rating e.g. “85°C” See paragraph 3 1. Protection Methods in Hazardous Areas. 3 Theoretical. Little precedent for use in Zone 1. Type Symbol Zone Comments Flameproof ‘d’ 1 &2 Relies on containment of any explosion inside the coil housing Intrinsic safety ‘ia’ 0 Increased safety ‘e’ 1&2 Relies on design criteria Non-incendive ‘N’ 2 Relies on design criteria 3 Low power technique. Insignificant energy to create an explosion. (permits two failure conditions) Other protection methods such as oil immersion (‘o’) or powder filling (‘q’) are usually associated with products other than solenoid valves. 2. Apparatus or Gas Groups. There are 2 main gas groups: Group I relates specifically to mining applications. Group II applies to all applications other than mining and is subdivided into: Group IIA - Propane Group IIB - Ethylene Group IIC - Hydrogen Group IIA includes the least incendive gases and IIC the most incendive. For standardization and safety reasons, valve manufacturers usually fit solenoids certified for group IIC gases. It should be noted that American incendivity groups go in reverse, A being the most incendive and D the least. PHOTOGRAPH COURTESY OF BAE SYSTEMS MARINE LIMITED We are here to help! Protect your system with a relief valve. 38 3. Surface Temperature. 4 Most gases will not ignite without a heat source. This could be any heated object, not necessarily a naked flame, approaching the gas flash point. Hazardous area equipment is therefore designed to limit surface temperature in continuous or intermittent operation, so as to minimize the risk of ignition of surrounding gases. ‘G’ in Germany. 5 Based on an ambient of 40°C (104ºF). Apparatus Temperature Classification Class Maximum (T)4 Surface Temperature (°C/ºF)5 T1 450°C/842ºF T2 300°C/572ºF T3 200°C/392ºF T4 135°C/275ºF T5 100°C/212ºF T6 85°C/185ºF Maxseal solenoid valves can be installed in ambient temperatures of up to 90°C (194ºF) while still retaining a T4 rating. Hazardous areas standards for dust and fibres (zones 10 and 11) are not covered here, nor are the USA standards. Please contact FCX Thompson Valves regarding these types of hazardous areas, and any other matter where installation guidance or valve selection information is needed. PHOTOGRAPH COURTESY OF SHELL General Note. 39 Maxseal Solenoid Valves. Valve Flow Characteristics. Table 1 Flow Coefficients Valve Type Nominal Size Flow Path (") (mm) 1/4 6 10 15 20 25 32 40 50 60 75 100 3/8 1/2 3/4 1 11/4 11/2 2 21/2 3 4 Cv Kv (bar g) Valve Flow Coefficients C B Conductance Critical Pressure (l/s/ Ratio bar abs) (USgpm for 1 psi ∆p) (l/min (m3/hr for 1 bar ∆p) for 1 bar ∆p) 20 20 20 20 20 20 20 20 20 20 20 3.7 10 15 27 50 70 106 190 270 380 630 0.8 1.7 3.2 6.8 12.8 18 28 48 70 100 165 11.5 24.5 46 98 184 259 403 691 1008 1440 2376 Maximum Pressure Any Any Any Any Any Any Any Any Any Any Any Density Relative to Air (G) 1.0 0.068 0.96 1.10 0.138 1.38 0.69 2.90 4.55 1.52 0.96 0.59 0.55 Symbol N2 + O 2 H2 N2 O2 He A Ne Kr Xe CO2 CO NH3 CH4 Actual Density (kg/m3) 1.2 0.082 1.15 1.32 0.166 1.66 0.83 3.48 5.46 1.824 1.15 0.71 0.67 Density figures at 293ºK and 1.018 bar (14.7 psi). Glossary of Terms. Conductance (C) The conductance is a constant value that is the ratio of airflow across the valve to inlet pressure p1 at choked flow conditions. Critical Pressure Ratio (B) The critical pressure ratio of a pneumatic component is the ratio of outlet pressure to inlet pressure where choked flow is reached. Table 3 Media Characteristics - Liquids 40 0.69 1.46 2.75 5.84 11 15.5 24 41.2 60.2 86 141.9 We are here to help! www.fcx-thompson-valves.com Table 2 Media Characteristics - Gases Medium Air Hydrogen Nitrogen Oxygen Helium Argon Neon Krypton Xenon Carbon dioxide Carbon monoxide Ammonia Methane 0.32 0.33 0.35 0.35 0.36 0.38 0.39 0.39 0.4 0.4 0.4 Kv Medium Symbol Mass Density (kg/l) Water Heavy water Shell Tellus T15 Olive oil Ethanol H2O D2O C2H5OH 1.0 1.1 0.86 0.9 0.8 Kv The Kv value for a valve is the flow rate of water through the valve in l/min or in m3/hr when the ∆p across the valve is 1 bar. Cv The Cv value for a valve is the flow rate of water through the valve in USgpm for a 1 psi ∆p. Liquid Flow. Gas Flow. The flow rate of a liquid through a valve is given by: The following modes of calculation are based on BS 7294:1990; ISO 6358:1989. Q = Kv • ∆p γ Where: Q = Flow rate l/min γ = Mass density in kg/l at process temperature and pressure (water @ 20ºC = 1 kg/l) ∆p = p1 - p2 p1 = inlet pressure in bar abs. p2 = outlet pressure in bar abs. Kv = Flow rate of water through the valve in l/min when ∆p across the valve is 1 bar. For comparison and conversion purposes, the Cv (USgpm for 1 psi) and Kv (m3/hr for 1 bar) are also given in Table 1. 1. For non-choked flow (low flow conditions i.e. p2/p1>B) p2 Q = C • p1 √G T0 • • T1 1- p1 2 -B 1-B Where: Q = Flow rate in normal (N) l/s C = Conductance in l/s/bar abs. See Table 1. B = Critical pressure ratio. See Table 1. p = Pressure in bar abs. p1 = inlet pressure in bar abs. p2 = outlet pressure in bar abs. G = Specific gravity relative to air. T = Temperature. T0 = 293ºK T1 = Upstream temperature ºK 2. For choked flow (high flow conditions i.e. p2/p1<B) Q = C • p1 √G T0 • T1 Critical pressure ratio Choked flow Non-choked flow Flow rate Varying inlet pressure p2 We are here to help! When you've browsed this overview, talk to us about the best solution for your system. 41 Maxseal Solenoid Valves. Valve Flow Characteristics. Example Gas Flow Calculations. Non-choked flow. What is the maximum flow of methane through a 1" SOV with an inlet pressure of 15 bar and a pressure drop of 7 bar? Choked flow. What is the maximum flow of air (to atmosphere) through a 1/4" ICO4 valve with an inlet pressure of 4.5 bar? Is the flow choked? For choked flow, p2/p1 = 0.36 (critical pressure ratio). p2, the outlet pressure, is equal to 9 bar abs (16 - 7 bar) and p1, the inlet pressure, is equal to 16 bar abs (1 + 15 bar). Is the flow choked? For choked flow, p2/p1 = 0.32 (critical pressure ratio). p2, the ambient air pressure, is equal to 1 bar abs and p1, the inlet pressure, is equal to 5.5 bar abs (1 + 4.5 bar). As p2/p1 = 0.56, the flow is choked. As p2/p1 = 0.18, the flow is choked. Determine flow Using Table 1, conductance C for 1" valve = 50 l/s/bar abs And, from Table 2, specific gravity of methane relative to air is 0.55 Determine flow Using Table 1, conductance C for 1/4" valve = 3.7 l/s/bar abs Therefore Q = C • p1 = 3.7 x 5.5 = 20.4 l/s Therefore p2 Q = C • p1 √G 1- p1 2 -B 1-B = 9 50 x 16 0.55 1- 16 2 - 0.36 = 1022 l/s 1 - 0.36 We are here to help! Filters contribute to longer system life. 42 Valve Flow Performance. Chart 1. Air Flow, ICO4 1/4", Low Pressure 20 bar max., universal C = 3.7, B = 0.3, Cv = 0.8 USgpm 90 80 Inlet pressure (bar g) Flow rate (N l/s) air 70 20 60 18 50 16 14 40 Ex. 2 30 12 10 8 20 6 4 10 0 0 5 10 15 Outlet pressure (bar g) Ex. 1 20 25 Example 1: What is the flow rate at 20 bar inlet and 18 bar outlet pressures (i.e. 2 bar ∆p)? Answer: 40 N l/s. Example 2: What is the ∆p at inlet 10 bar and 32 l/s flow? Answer: 10 - 7 = 3 bar. Chart 2. Air Flow, ICO4 1/2", Low Pressure 20 bar max., universal C = 15, B = 0.35, Cv = 4.2 USgpm 350 300 Flow rate (N l/s) air Inlet pressure (bar g) 250 20 18 200 16 14 150 12 10 100 8 6 4 50 0 0 5 10 15 20 25 Outlet pressure (bar g) 43 Maxseal Solenoid Valves. Valve Flow Performance. Chart 3. Liquid Flow, ICO4 1/4", Low Pressure 20 bar max., Cv = 0.8 USgpm Fluid water at density 1 kg/l 70.0 Flow rate (N l/min) water 60.0 50.0 40.0 30.0 Inlet pressure (bar g) 20.0 10.0 2 6 4 8 12 10 14 16 18 20 0.0 0 5 10 15 20 25 Outlet pressure (bar g) Chart 4. Liquid Flow, ICO4 1/4", High Pressure 207 bar max., Cv = 0.28 USgpm 160.0 140.0 Flow rate (N l/min) water 120.0 100.0 80.0 Inlet pressure (bar g) 60.0 40.0 20 20.0 60 40 80 100 120 140 160 180 207 220 0.0 0 50 100 150 Outlet pressure (bar g) 44 200 250 Chart 5. Flow Test, ICO4 1/4" 90 80 70 Q Flow rate (N l/s) 60 N M P O 50 L I J 40 R K H 30 G D 20 B C F A E 10 0 0 5 10 15 20 25 Outlet pressure (bar g) A B C D E F G H I J K L M N O P Q R Theoretical flow for 4 bar g inlet pressure Actual flow for 4 bar g inlet pressure Theoretical flow for 6 bar g inlet pressure Actual flow for 6 bar g inlet pressure Theoretical flow for 8 bar g inlet pressure Actual flow for 8 bar g inlet pressure Theoretical flow for 10 bar g inlet pressure Actual flow for 10 bar g inlet pressure Theoretical flow for 12 bar g inlet pressure Actual flow for 12 bar g inlet pressure Theoretical flow for 14 bar g inlet pressure Actual flow for 14 bar g inlet pressure Theoretical flow for 16 bar g inlet pressure Actual flow for 16 bar g inlet pressure Theoretical flow for 18 bar g inlet pressure Actual flow for 18 bar g inlet pressure Theoretical flow for 20 bar g inlet pressure Actual flow for 20 bar g inlet pressure 45 Maxseal Solenoid Valves. Valve Flow Performance. Chart 6. Flow Test, ICO4 1/2" At 10 bar inlet pressure for lift of 0.055" 200 180 Actual flow rate 160 Theoretical flow rate Flow rate (N l/s) 140 120 100 80 60 40 20 0 0 2 4 6 8 10 12 Outlet pressure (bar g) Chart 7. Flow Test, ICO4 1/2" At 20 bar inlet pressure for lift of 0.055" 400 Actual flow rate 350 Flow rate (N l/s) 300 Theoretical flow rate 250 200 150 100 50 0 0 5 10 15 Outlet pressure (bar g) 46 20 25 Maxseal Solenoid Valves. Conversion Chart. To convert Unit (Symbol) into Unit (Symbol) To convert Unit (Symbol) from Unit (Symbol) atmospheres (Atm) bar (bar) 1.013250 cubic feet (ft3) Multiply by Divide by litres (l) 28.3161 cubic inches (in3) centilitres (cl) 1.63866 feet (ft) metres (m) 0.3048 feet of water (ft H2O) bar (bar) 0.0298907 foot pounds force (ft lbf) joules (J) 1.35582 foot pounds force/minute (ft lbf/min) watts (W) 81.3492 gallons, UK (UK gal) litres (l) 4.54596 gallons, US (US gal) litres (l) 3.78531 horsepower (hp) kilowatts (kW) 0.7457 inches of mercury (in Hg) millibar (mbar) 33.8639 inches of water (in H2O) millibar (mbar) 2.49089 inches (in) centimetres (cm) 2.54 kilogramme force (kgf) newtons (N) 9.80665 kilogramme force metre (kgf m) newton metres (Nm) 9.80665 kilopascals (kPa) bar (bar) 0.01 millimetres of mercury (mm Hg) millibar (mbar) 1.33322 millimetres of water (mm H2O) millibar (mbar) 0.09806 bar (bar) 0.1 kilogrammes (kg) 0.4536 newtons/square centimetre (N/cm2) pounds (lb) pounds/cubic foot (lb/ft3) pounds/cubic inch kilogrammes/cubic metre (kg/m3) (lb/in3) kilogrammes/cubic centimetre (kg/cm3) 16.0185 0.0276799 pounds force (lbf) newtons (N) 4.44822 pound force feet (lbf ft) newton metres (Nm) 1.35582 newton metres (Nm) 0.112985 bar (bar) 0.06894 pounds force inches (lbf in) pounds force/square inch square feet (ft2) square inches (in2) (lbf/in2) square metres (m2) square centimetres (cm2) 0.092903 6.4516 We are here to help! Remember that complete spares kits are available. 47 FCX Thompson Valves designs and manufactures exclusive valve products for the most demanding applications. We offer cost-effective integrated product packages, supported by the resources of the FCX Flow Control division. Maxseal Solenoid Valves Resilient, low power consumption, fast acting instrument changeover and solenoid valves. Ashford BellowsSealed and Gland Packed Needle Valves and Manifolds Compact, lightweight and robust, widely used in nuclear applications. Maxseal IVP Pressure Regulators NHI Bellows-Sealed Globe Valves Pressure regulators and relief valves with high performance accuracy for all process fluids, including nuclear applications. High-integrity forged valves, specifically designed for nuclear duties. Service and Refurbishment Centre Specialist Packaged Solutions Dedicated service engineers for installation and refurbishment. • HP air management systems. • Cryogenic valves for aerospace applications. product specifications or designs without notice. Information is given in good faith and no liability can be accepted for any error or omission. Classes 1, 2 and 3 A Division of FCx Manufacturing UK Ltd QACA 225 Rev. 3 BASEEFA/EECS Licence M3782 BS EN ISO 9001: 1994 Certificate No. FM 315 FCX Thompson Valves 17 Balena Close Creekmoor, Poole Dorset BH17 7EF, England Tel +44 (0)1202 697521 Fax +44 (0)1202 605385 sales@fcx-thompson-valves.com www.fcx-thompson-valves.com FRONT COVER PHOTOGRAPH COURTESY OF SHELL FCX Thompson Valves reserves the right to amend
Similar documents
to view catalog
CHAIN LINK………………………………………...43 – 47 Black and green colored chain link system………………………………….43,44 Galvanized systems…………………………………………………………..44-47
More information