March 31st, 2016 28767 West Hils Drive Santa Clarita, California
Transcription
March 31st, 2016 28767 West Hils Drive Santa Clarita, California
CONSTRUCTION DOCUMENTS West Creek Academy 28767 West Hils Drive Santa Clarita, California 91354 March 31st, 2016 PTN 64998-55 CONSTRUCTION TYPE: V- B SPRINKLERS: YES TOTAL BUILDING AREA: 9,048 SQ FT STORIES: 1 BUILDING HEIGHT: NOTE: SEE CP1.1 FOR ADDITIONAL CODE ANALYSIS DESIGN TEAM DLR GROUP 3130 WILSHIRE BLVD., 6TH FLOOR SANTA MONICA, CALIFORNIA 90403 CONTACT: VIRGINIA MARQUARDT vmarquardt@dlrgroup.com (310) 828-0040 WE ST H ILLS DRI VE CIVIL ENGINEER PSOMAS 28480 AVENUE STANFORD, STE 200 SANTA CLARITA, CA 91355 DAVID MARTIN dmartin@psomas.com (661) 705-4439 GEOTECHNICAL ENGINEER RMA GEOSCIENCE, INC. 9854 GLENOAKS BLVD SUN VALLEY, CA 91352 MARK SWIATEK mswiatek@rmageoscience.com (800) 762-4396 WES T CR EEK DR. COVER SHEET SYMBOLS, ABBREVIATIONS and GENERAL NOTES FIRE ACCESS PLAN CIVIL; C-0.0 C-1.0 C-1.1 C-2.0 TITLE SHEET DEMOLITION PLAN EROSION AND SEDIMENT CONTROL PLAN FINE GRADING & DRAINAGE PLAN ARCHITECTURAL; CP1.1 CODE PLAN AS1.00 ARCHITECTURAL SITE PLAN AS1.01 SITE DETAILS ELECTRICAL; E0.0 E0-1 E1.1 E1.2 E2-1 E3-1 E4-1 E5-1 GENERAL NOTES AND SYMBOL LIST ELECTRICAL SPECIFICATIONS ELECTRICAL SITE PLAN ELECTRICAL SITE PLAN, ENLARGED ENLARGED POWER AND DATA PLAN ENLARGED FIRE ALARM PLAN ELECTRICAL DETAILS ELECTRICAL ONE-LINE DIAGRAM PORTABLE BUILDING PC DRAWINGS WEST CREEK ACADEMY CAMPUS DSA # 04-103659 ARCHITECTURAL T G.1 G.2 G.3 G.4 A.1.24 A.3.24 A.4.24 M.1.24 M.1.24 TITLE SHEET GENERAL SPECIFICATIONS SPECIFICATIONS AND SCHEDULES ARCHITECTURAL STANDARD DETAILS PLUMBING GENERAL NOTE AND DETAILS 24'x40' FLOOR PLAN, ELEVATION & ROOF PLAN (DUAL PITCH) 24'x40' INTERIOR ELEVATIONS 24'x40' REFLECTED CEILING PLAN & DETAILS 24'x40' MECHANICAL PLAN 24'x40' ELECTRICAL PLAN Interim Housing E & A3 GENERAL; 0.0 0.1 FP-01 COVER SHEET OCCUPANCY: CLIENT SAUGUS UNION SCHOOL DISTRICT 24930 AVENUE STANFORD SANTA CLARITA, CA 91355 MAGDY ABDALLA mabdalla@saugususd.org (661) 294-5300 VIS TA DE LR IO DR IVE 28767 WEST HILLS DRIVE, SANTA CLARITA 91354 Index of Drawings Vicinity Map HIL LD RIV E ADDRESS: Project Directory CO PP ER Building Information Saugus Union School District - West Creek Academy 28767 WEST HILLS DRIVE INTERIM HOUSING Saugus Union School District Project Scope ADDITION OF FOUR (4) RELOCATABLE CLASSROOM BUILDINGS FIRE ALARM SYSTEM CONNECTED TO THE CAMPUS FIRE ALARM SYSTEM S.70 S.70A S.73 S.73A R-1 RELATED SITE AND ACCESSIBLE PATH OF TRAVEL; FINE GRADING FLATWORK SITE UTILITIES 4/4/2016 3:46:25 PM 2013 CALIFORNIA BUILDING STANDARDS ADMINISTRATIVE CODE, TITLE 24 C.C.R. 2013 CALIUFORNIA BUILDING CODE, TITLE 24 C.C.R. (2012 INTERNATIONAL BUILDING CODE OF THE INTERNATIONAL CODE COUNCIL, WITH CALIFORNIA AMENDMENTS) PART 3 2013 CALIFORNIA ELECTRICAL CODE, TITLE 24 C.C.R. (2012 NATIONAL ELECTRICAL CODE OF THE NATIONAL FIRE PROTECTION ASSOCIATION, NFPA) PART 4 2013 CALIFORNIA MECHANICAL CODE, TITLE 24 C.C.R. (2012 UNIFORM MECHANICAL CODE OF THE INTERNALTIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS, IAPMO) PART 5 2013 CALIFORNIA PLUMBING CODE, TITLE 24 C.C.R. (2012 UNIFORM PLUMBING CODE OF THE INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS, IAPMO) PART 6 2013 CALIFORNIA ENERGY CODE, TITLE 24 C.C.R. PART 9 2013 CALIFORNIA FIRE CODE, TITLE 24 C.C.R. (2012 INTERNATIONAL FIRE CODE OF THE INTERNATIONAL CODE COUNCIL) PART 10 2010 CALIFORNIA EXISTING BUILDING CODE, TITLE 24, C.C.R. (2009 INTERNATIONAL EXISTING BUILDING CODE OF THE INTERNATIONAL CODE COUNCIL, WITH AMENDMENTS) PART 11 2010 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREEN CODE), TITLE 24 C.C.R. PART 12 2010 CALIFORNIA REFERENCED STANDARDS CODE, TITLE 24 C.C.R. C:\Revit\75-15270-01_AR_2015_Cental_mfrey.rvt PART 1 PART 2 DSA REQUIREMENTS ALL WORK SHALL CONFORM TO 2013 EDITION, TITLE 24 CALIF. CODE OF REGULATIONS (CCR) CHANGES TO THE APPROVED DRAWINGS AND SPECIFICATIONS SHALL BE MADE BY ADDENDA OR CHANGE ORDERS APPROVED BY THE DIVISION OF THE STATE ARCHITECT, AS REQUIRED BY SECTION 4-338, PART I, TITLE 24, CALIFORNIA CODE OF REGULATIONS. GRADING PLANS, DRAINAGE AND ROAD IMPROVEMENTS, AND ENVIRONMENTAL HEALTH CONSIDERATIONS SHALL COMPLY WITH ALL LOCAL ORDINANCES. A CLASS 3 INSPECTOR CERTIFIED BY THE DIVISION OF THE STATE ARCHITECT, EMPLOYED BY THE OWNER, AND APPROVED BY THE DIVISION OF THE STATE ARCHITECT SHALL PROVIDE CONTINUOUS INSPECTION OF THE WORK. THE DUTIES OF THE INSPECTOR ARE DEFINED IN SECTION 4-342, PART I, TITLE-24, CALIFORNIA CODE OF REGULATIONS. COMPLIANCE WITH CFC CHAPTER 14 - FIRE SAFETY DURING CONSTRUCTION AND DEMOLITION. A DSA ACCEPTED TESTING LABORATORY DIRECTLY EMPLOYED BY THE SCHOOL BOARD SHALL CONDUCT ALL REQUIRED TESTS AND INSPECTIONS FOR THE PROJECT. THE TEMPORARY CERTIFICATION GRANTED UNDER THIS APPLICATION PER THE CALIFORNIA ADMINISTRATIVE CODE, SECTION 4-302 (b) IS VALID FOR TWENTY-FOUR MONTHS. Symbol Legend EXISTING FIRE ACCESS LANE PROPOSED FIRE ACCESS LANE SCOPE OF WORK PROPOSED BUILDING Statement of General Conformance STATEMENT OF GENERAL CONFORMANCE I FIND THAT: FOR ARCHITECTS/ENGINEERS WHO UTILIZE PLANS, INCLUDING BUT NOT LIMITED TO SHOP DRAWINGS, PREPARED BY OTHER LICENSED DESIGN PROFESSIONALS AND/OR CONSULTANTS FOR THE FOLLOWING DRAWINGS OR SHEETS: ALL CIVIL DRAWINGS PER "INDEX OF DRAWINGS " ON SHEET 0.0-1 HAVE BEEN PREPARED BY OTHER DESIGN PROFESSIONALS OR CONSULTANTS WHO ARE LICENSED AND/OR AUTHORIZED TO PERPARE SUCH DRAWINGS IN THIS STATE. THESE DRAWINGS OR SHEETS HAVE BEEN EXAMINED BY ME FOR: 1. DESIGN INTENT AND APPEARS TO MEET THE APPROPRIATE REQUIREMENTS OF TITLE 24, CCR, AND THE PROJECT SPECIFICATIONS PREPARED BY ME, AND 2. COORDINATION WITH MY PLANS AND SPECIFICATIONS AND IS ACCEPTABLE FOR INCORPORATION INTO THE CONSTRUCTION OF THIS PROJECT. THIS STATEMENT OF GENERAL CONFORMANCE SHALL NOT BE CONSTRUED AS RELIEVING ME OF MY RIGHTS, DUTIES, AND RESPONSIBILITIES UNDER SECTION 17302 AND 81138 OF THE EDUCATION CODE AND SECTIONS 4-306, 4-341, AND 4-344 OT THE TITLE 24 , PART 1. (TITLE 24, PART 1, SECTION 4-317(b)). COVER SHEET, BLDG DATA, SHEET INDEX GENERAL NOTES AND SPECIFICATIONS CONSTRUCTION NOTES, BLDG, MATERIALS, DOOR, WINDOW & SCHEDULES STANDARD ARCHITECTURAL DETAILS 24'X40' FLOOR PLAN, DUAL SLOPE EXTERIOR ELEVATIONS & ROOF PLAN 24'X40' INTERIOR ELEVATIONS 24'X40' REFLECTED CEILING PLAN & DETAILS 24'X40' MECHANICAL PLAN 24'X40' ELECTRICAL LIGHTING/POWER PLAN & FIRE ALARM STUCTURAL ALL DRAWINGS OR SHEETS LISTED ON THE COVER OR INDEX SHEET FOR EACH DISCIPLINE (SEE SHEET INDEX FOR LIST OF DISCIPLINES) S.1 S-5 THIS DRAWING OR PAGE ARE IN GENERAL CONFORMANCE WITH THE PROJECT DESIGN, AND HAVE BEEN COORDINATED WITH THE PROJECT PLANS AND SPECIFICATIONS. CS G.1 G.2 G.4 A.1.24 A.2.24 A.3.24 M.1.24 E.1.24 ARE IN GENERAL CONFORMANCE WITH THE PROJECT DESIGN INTENT, AND HAVE BEEN COORDINATED WITH THE PROJECT PLANS AND SPECIFICATIONS. S.10 S.20 S.30 S.41 S.51 S.60 GENERAL NOTES & SPECIFICATIONS RIGID FRAME SECTRIONS & DETAILS, DUAL SLOPE W/ LIGHT GA SIDEWALL BEAM W/ TRUSS @ MODLINE W/ PLYWOOD FLOOR (80 MPH WIND) FLOOR FRAMING PLAN & DETAILS W/PLYWOOD FLOOR (80 & 90 MPH WIND) EXTERIOR WALL FRAMING ELEVATIONS (WOOD STUDS, 80 MPH WIND) WOOD STUD WALL FRAMING DETAILS (80 MPH WIND) ROOF FRAMING PLAN W/22 GA. ROOF (80 & 90 MPH WIND) ROOF FRAMING DETAILS W/22 GAUGE ROOF (80 & 90 MPH WIND) DUAL SLOPE TRUSS & DETAILS 20 PSF ROOF (80 MPH WIND) R-1 RAMP FRAMING & DETAILS (4'-0" WIDE RAMP) FOUNDATION SIGNATURE DATE ARCHITECT OR ENGINEER DESIGNATED TO BE IN GENERAL RESPONSIBLE CHARGE SIGNATURE DATE ARCHITECT OR ENGINEER DELEGATED RESPONSIBILITY FOR THIS PORTION OF THE WORK VIRGINIA MARQUARDT, AIA PRINT NAME PRINT NAME C 33423 06/30/2017 LICENSE NUMBER EXPIRATION DATE LICENSE NUMBER EXPIRATION DATE F-1 WOOD PAD FPUNDATION & DETAILS (50 PSF FLOOR, 20 & © LIST OF CODES AND STANDARDS , DLR Group inc., a California corporation, ALL RIGHTS RESERVED DSA # 04-106743 ARCHITECTURAL Architecture Engineering Planning Interiors 2013 CALIFORNIA BUILDING CODE (FOR SFM) REFERENCED STANDARDS CHAPTER 35 NFPA 17 DRY CHEMICAL EXINGUISHING SYSTEMS 2002 EDITION NFPA 17A WET CHEMICAL EXINGUISHING SYSTEMS 2002 EDITION NFPA 24 PRIVATE FIRE NFPA 72 NATIONAL FIRE ALARM CODE (CALIFORNIA AMENDED) 2010 EDITION (NOTE: SEE UL STANDARD 1971 FOR "VISUAL DEVICES") NFPA 80 FIRE DOOR AND OTHER OPENING PROTECTIVES 2007 EDITION NFPA 253 CRITICAL RADIANT FLUX OF FLOOR COVERING SYSTEMS 2006 EDITION 2005 NFPA 110 EMERGENCY AND STANDBY POWER SYSTEMS ASTM STANDARD CHANGES (EXAMPLE: ASTM E648-04 STANDARD TEST METHOD FOR CRITICAL RADIANT FLUX OF FLOOR) UL STANDARD CHANGES (EXAMPLES :2005 UL 38 MANUAL OPERATING SIGNAL BOXES AND 2005 UL 1424 CABLES FOR POWER- LIMITED FIRE PROTECTIVE SIGNALING CIRCUITS) TITLE 19 CCR STATE FIRE MARSHAL REGULATIONS 2003 UL 464 AUDIBLE SIGNAL APPLIANCES 1999 UL 521 HEAT DETECTORS FOR FIRE PROTECTIVE SIGNALING SYSTEMS 2002 UL 1971 SIGNALING DEVICES FOR THE HEARING IMPAIRED Revisions PARTIAL LIST OF APPLICALBE STANDARDS: STRUCTURAL GENERAL NOTE WELDING REQUIREMENTS GENERAL NOTES 80 MPH DOUBLE STOP COLD ROLLED/TRUSS RIGID FRAME 90 MPH RIGID FRAME SECTION & DETAILS 80 & 90 MPH FLOOR CONSTRUCTION DETAILS 80 & 90 MPH FLOOR FRAMING PLAN 80 MPH WALL FRAMING WOOD STUDS 80 & 90 MPH WALL FRAMING STEEL STUDS 90 MPH EXTERIOR WALL FRAMING STUDS 80 & 90 MPH STEEL STUD FRAMING DETAIL 80 & 90 MPH STEEL STUD FRAMING DETAIL 80 & 90 MPH INT. AND EXT. WALL CONSTRUCTION DETAILS 80 MPH ROOF CONSTRUCTION PLAN 20 & 30 PSF ROOF 80 MPH ROOF CONSTRUCTION PLAN 20 & 30 PSF ROOF 80 & 90 MPH ROOF CONSTRUCTION DETAILS FOR COLD ROLLED WITH METAL ROOFING 20 & 30 PSF ROOF 80 MPH STEEL TRUSS FOR DOUBLE PITCHED ROOF (20 PSF) 80 MPH STEEL TRUSS FOR DOUBLE PITCHED ROOF (30 PSF) 90 MPH STEEL TRUSS FOR DOUBLE PITCHED ROOF (20 PSF) 90 MPH STEEL TRUSS FOR DOUBLE PITCHED ROOF (30 PSF) RAMP FRAMING PLAN AND DETAILS 75-15270-01 Issue Date; 03/31/2016 General Notes S.1 S.1A S.5A S.6 S.10 S.11 S.20 S.20A S.21 S.25 S.26 S.30 S.40 S.41 S.60 0.0 STRUCTURAL ABBREVIATIONS L L LA LAB LAM LAT LAV LB LBR LBS LDG LF LG LIN LINO LKR LL LLH LLV LOC LONG LOX LPG LPR LPS LR LS LSC LT LTD LTG LV LV LW LWT ANGLE LAVATORY LABORATORY COMPRESSED AIR LABORATORY LAMINATE(D) LEAVING AIR TEMPERATURE LAVATORY POUND LUMBER POUNDS LOADING LINEAR FOOT (FEET) LENGTH (LONG) LINEAR LINOLEUM LOCKER LIVE LOAD LONG LEG HORIZONTAL LONG LEG VERTICAL LOCATION LONGITUDINAL LIQUID OXYGEN LIQUEFIED PETROLEUM GAS LOW PRESSURE STEAM RETURN LOW PRESSURE STEAM SUPPLY LIVING ROOM LAWN SPRINKLER LIFE SAFETY CODE LIGHT LINED TRANSFER DUCT LIGHTING LOUVER LABORATORY VACUUM LONG WAY LEAVING WATER TEMPERATURE M MA MA MAC MAG MAINT MAN MAS MATL MAU MAV MAX MB MB MBD MBH MBTUH MC MC MCA MCB MCM MD MDO MECH MEMB MET MEZZ MFR MFRG MG MH MH MH MIN MISC ML MLDG MLO MLWK MO MPG MPR MPS MR MR/S MS MTD MTG MTL MTWR MTWS MUL MV MV MW THOUSAND MIXED AIR MEDICAL COMPRESSED AIR MACHINE MAGNETIC MAINTENANCE MANUAL MASONRY MATERIAL MAKEUP AIR UNIT MANUAL AIR VENT MAXIMUM MACHINE BOLT MOP BASIN MARKER BOARD THOUSAND BTU PER HOUR THOUSAND BTU PER HOUR MECHANICAL CONTRACTOR MEDICINE CABINET MINIMUM CIRCUIT AMPS MAIN CIRCUIT BREAKERJ THOUSAND CIRCULAR MILLS MANUAL VOLUME DAMPER MEDIUM DENSITY OVERLAY MECHANICAL MEMBRANE METAL MEZZANINE MANUFACTURER MANUFACTURING MOTOR GENERATOR MANHOLE METAL HALIDE MOP HOLDER MINIMUM MISCELLANEOUS MOTORIZED LOUVER MOLDING MAIN LUGS ONLY MILLWORK MASONRY OPENING MEDIUM PRESSURE GAS MEDIUM PRESSURE STEAM RETURN MEDIUM PRESSURE STEAM SUPPLY MIRROR MIRROR WITH SHELF MAGNETIC STARTER MOUNTED MOUNTING METAL MEDIUM TEMP HOT WATER RETURN MEDIUM TEMP HOT WATER SUPPLY MULLION MERCURY VAPOR MEDICAL VACUUM MARKER WALL N N N2O N/A NITROGEN NORTH NITROUS OXIDE NOT APPLICABLE P PAINT P POLE P/T PRESSURE/TEMPERATURE TEST PORT P PUMP PA PUBLIC ADDRESS PAN B PANIC BOLT PAR PARALLEL PB PARTICLE BOARD PB PULL BOX PB PUSH BUTTON PBS PUSH BUTTON STATION PC PRECAST PC PUMPED CONDENSATE PCD PAPER CUP DISPENSER PCF POUNDS PER CUBIC FOOT PCT PORCELAIN CERAMIC TILE PD PRESSURE DROP PD PUMP DISCHARGE PDI PLUMBING & DRAINAGE INSTITUTE PENT PENTHOUSE PERF PERFORATED PERP PERPENDICULAR PF POWER FACTOR PG PRESSURE GAGE PH PHASE PI POINT OF INTERSECTION PI PRESSURE INDICATOR PIC PORTABLE INSTRUMENT CONNECTION PIV POST INDICATOR VALVE PL PLACE(S) PL PLATE PLAM;PL PLASTIC LAMINATE PLAS PLASTER PLBG PLUMBING PLYWD PLYWOOD PNEU PNEUMATIC PNL PANEL POC POINT OF CONNECTION PORC PORCELAIN PPM PARTS PER MILLION PR PAIR PREFAB PREFABRICATED PROJ PROJECTION PRV PRESSURE REDUCING VALVE PS PIPE SUPPORT PS PROJECTION SCREEN PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PSV PRESSURE SAFETY VALVE PT PLASTER TRAP PT POINT PT POTENTIAL TRANSFORMER PTD PAPER TOWEL DISPENSER PTD/R COMBINATION TOWEL DISPENSER/RECEPTACLE PTN PARTITION PVC POLYVINYL CHLORIDE PVI POINT OF VERTICAL INTERSECTION PVT POINT OF VERTICAL TANGENCY PWL SOUND POWER LEVEL PWR POWER QT QUARRY TILE QTR RND QUARTER ROUND R RA RAD RAD or R RB RC RCP RCP RCU RD RD RECP REF REFL REFR REFR REG REINF REM REQ(D) RESIL RET REV RF RF RFM RH RH RHC RH RHG RI&C RIJS RL RM RND RO RISER RETURN AIR RADIATOR RADIUS RUBBER BASE REMOVE CONTROL REFLECTED CEILING PLAN REINFORCED CONCRETE PIPE RECIPROCATING CHILLER JOINT ROOF DRAIN REFRIGERANT DISCHARGE RECEPTACLE REFERENCE REFLECTED REFRIGERANT REFRIGERATOR REGISTER REINFORCEMENT REMOVABLE REQUIRE(D) RESILIENT RETAINING (WALL) REVISIONS RETURN FAN RUBBER FLOOR RECESSED FLOOR MAT RELATIVE HUMIDITY RELIEF HOOD REHEAT COIL ROBE HOOK REFRIGERANT HOT GAS ROUGH IN AND CONNECT RISE IN JOIST SPACE REFRIGERANT LIQUID ROOM ROUND ROUGH OPENING S SINK S SANITARY SEWER S SOAP DISH S SOUTH S SPRINKLER LINE SA SHOCK ABSORBER SA SUPPLY AIR SAN SANITARY WASTE SC SECURITY SC SOLID CORE SC SHOWER CURTAIN SC SPECIAL COATING SCD SEAT COVER DISPENSER SCH SHOWER CURTAIN HOOKS SCHED SCHEDULE SCR SHOWER CURTAIN ROD SCT STRUCTURAL CLAY TILE SCUT SCUTTLE SCW SOFT COLD WATER SD SOAP DISPENSER SD SMOKE DAMPER SD SMOKE DETECTOR SD STORM DRAIN SE STEAM EXHAUST VENT SEC SECONDARY SECT SECTION SECY SECRETARY SENS SENSIBLE SF SQUARE FOOT SF SUPPLY FAN SFCMU SPLIT-FACED CONCRETE MASONRY UNIT SFU STRUCTURAL FACING UNIT SGL SINGLE SH SHOWER SHEATH SHEATHING SHM SECURITY HOLLOW METAL SHT SHEET SHWSOFT HOT WATER SIM SIMILAR SL SHORT LEG SLNT SEALANT SM SHEET METAL SM SPRINKLER MAIN SND SANITARY NAPKIN DISPOSAL SNV SANITARY NAPKIN VENDOR SP STATIC PRESSURE (H2O) SP STAND PIPE SP STATIC PRESSURE SPEC SPECIFICATIONS SPK SPRINKLER SPL SOUND PRESSURE LEVEL SPL SPECIAL SPL BLK SPLASH BLOCK SQ SQUARE SS STAINLESS STEEL SSA STORM SHELTER AREA SS SERVICE SINK SS SOLID SURFACE ST STAIR ST STORM SEWER STAG'D STAGGERED STC SOUND TRANSMISSION CLASS STD STANDARD STE SINGLE TAPERED END STGR STRINGER STL STEEL STOR STORAGE STR STRUCTURAL - STRUCTURE SUB SUBSTATION SUBFL SUBFLOOR SURF SURFACE SUSP SUSPENDED SV SHEET VINYL SV SOLENOID VALVE SW SHORT WAY SW SWITCH SWBD SWITCH BOARD SWP STEAM WORKING PORESSURE SYM SYMMETRICAL T T T&B T& G T TA TAB TAN TB TB TBD TC TC TD TD TDH TEL TEMP TEMP TERR TEXT TGL TH TH THK TMR TMV TOB TOC TOF TOIL TOP TOS TOW TPV TR TRANS TRD TS TSP TT TT TTD TV TW TYP TEMPERED THERMOSTAT TOP & BOTTOM TONGUE & GROOVE TREAD TRANSFER AIR TEST AND BALANCE TANGENT TERMINAL BOX TOWEL BAR TACK BOARD TEMPERATURE CONTROL TIME CLOCK TRANSFER DUCT TRENCH DRAIN TOTAL DYNAMIC HEAD TELEPHONE TEMPERED - TEMPORARY TEMPERATURE TERRAZZO TEXTURED TOGGLE THRESHOLD TOWEL HOOK THICK(NESS) TILT MIRROR UNIT THERMOSTATIC MIXING VALVE TOP OF BEAM TOP OF CONCRETE TOP OF FOOTING TOILET TOP OF PAVING TOP OF STEEL TOP OF WALL TRAP PRIMER TRIP TRANSVERSE TREAD TEMPERATURE SENSOR TOTAL STATIC PRESSURE TEMPERATURE TRANSMITTER TERRAZZO TILE TOILET TISSUE DISPENSER TELEVISION TACK WALL TYPICAL U UC UG URINAL UNIT COOLER UNDERGROUND UGE UGT UH UL UNEX UNFIN UNO UR URD US UTIL UV UNDERGROUND ELECTRICAL UNDERGROUND TELEPHONE UNIT HEATER UNDERWRITERS LABORATORIES UNEXCAVATED UNFINISHED UNLESS NOTED OTHERWISE URINAL UNDERGROUND RESIDENTIAL DISTRIBUTION UTILITY SHELF UTILITY UNIT VENTILATOR V V V VA VAC VAV VB VB VBF VCB VCP VCT VD VEL VENT VENT VERT VEST VF VFD VM VOL VP VP VSMC VT VTR VWC VENT VOLT VACUUM VALVE VACUUM VARIABLE AIR VOLUME VAPOR BARRIER VINYL BASE VENT BELOW FLOOR VENTED COVE BASE VITRIFIED CLAY PIPE VINYL COMPOSITION TILE VOLUME DAMPER - MANUAL VELOCITY VENTILATION VENTILATOR VERTICAL VESTIBULE VINYL FLOOR VARIABLE FREQUENCY DRIVE VOLTMETER VOLUME VENEER PLASTER VACUUM PUMP VARIABLE SPEED MOTOR CONTROLLER VINYL TILE VENT THROUGH ROOF VINYL WALLCOVERING W W W W W W W/ W/O WB WC WC WC WCC WCL WCO WD WDW WF WH WFMD WH WHM WI WLR WLS WMG WNSCT WP WPB WPF WPFG WR WR WSP WT WW WWF WATER SERVICE WIDE; WIDTH WASTE (PLUG) WATT WEST WIDE FLANGE WITH WITHOUT WET BULB WALL COVERING WATER COLUMN WATER CLOSET WATER COOLED CONDENSER WATER CLOSET/LAVATORY COMBINATION WALL CLEAN OUT WOOD WINDOW WASH FOUNTAIN WALL HYDRANT WATER FLOW MEASURING DEVICE WATER HEATER WATT HOUR METER WROUGHT IRON WATER LOOP RETURN WATER LOOP SUPPLY WATER MOTOR GONG WAINSCOT WEATHERPROOF WHIRLPOOL BATH WATERPROOF WATERPROOFING WATER RESISTANT WASTE RECEPTACLE WET STAND PIPE WEIGHT WARM WHITE WELDED WIRE FABRIC XFMR XMTR TRANSFORMER TRANSMITTER INCLUDE OWNER-FURNISHED AND INSTALLED ITEMS AND OWNER FURNISHED AND CONTRACTOR INSTALLED ITEMS IN THE CONSTRUCTION SCHEDULE, AND COORDINATE WITH OWNER TO ACCOMMODATE THESE ITEMS. YD YH YARD YARD HYDRANT REFER TO CIVIL DRAWINGS FOR ACTUAL ELEVATION OF ARCHITECTURAL FINISH FLOOR ELEVATION 0’-0” Z ZCV ZVB IMPEDANCE ZONE CONTROL VALVE ZONE VALVE BOX & @ i.e. # AND AT THAT IS NUMBER THE FOLLOWING ABBREVIATIONS ARE USED WITH GLAZING: CG CIG CTG CTIG LG PG PIG SG TG TIG TTG TTIG WG CLEAR FLOAT GLASS CLEAR INSULATING GLASS CLEAR TEMPERED FLOAT GLASS CLEAR TEMPERED INSULATING GLASS LAMINATED GLASS PATTERN GLASS PATTERN INSULATING GLASS SPANDREL GLASS TINTED FLOAT GLASS TINTED INSULATING GLASS TINTED TEMPERED FLOAT GLASS TINTED TEMPERED INSULATING GLASS POLISHED WIRE GLASS DETAIL NUMBER SIM ? CROSS REFERENCE ??? SHEET ON WHICH DRAWN SIMILAR OR TYPICAL REFERENCE EARTH GRAVEL/BALLAST SAND ? ??? WALL SECTION SIM SIMILAR OR TYPICAL REFERENCE ? ??? CONCRETE PRECAST CONCRETE SIM DETAIL REFERENCE STEEL GYM FLOOR SIM ? ??? ? ??? ? ? SIM BUILDING SECTION BUILDING ELEVATION INTERIOR ELEVATION WOOD (CONTINUOUS BLOCKING) WOOD (NON-CONTINUOS BLOCKING) WOOD (TRIM/FINISH) GLASS XX/ A11.X CASEWORK ELEVATION STONE SHINGLES ? ? LEGEND/KEY NOTE CONCRETE MASONRY UNIT COLUMN LINE BRICK VENEER METAL STUDS ROOM NAME ??? STEEL (LARGE SCALE) ROOM NUMBER PLYWOOD (LARGE SCALE) ? DOOR NUMBER GYPSUM WALL BOARD (LARGE SCALE) ??? WINDOW NUMBER BATT INSULATION ? WALL TYPE RIGID INSULATION PROTECTION BOARD CARPET (LARGE SCALE) DESCRIPTION REVISION NUMBER ACOUSTICAL TILE (LARGE SCALE) TILE (LARGE SCALE) GENERAL NOTES GENERAL NOTES APPLY TO ALL SHEETS. DIMENSIONS ARE ACTUAL AND ARE TO FACE OF STUDS UNLESS NOTED OTHERWISE. THE OWNER SHALL FURNISH AND INSTALL ALL EQUIPMENTS AND FURNITURES. ALL PARTS OF THE WORK - INCLUDING MATERIALS, METHODS, ASSEMBLIES, ETC - MUST COMPLY WITH THE MIN REQUIREMENTS OF THE GOVERNING REGULATIONS OF ALL FEDERAL, STATE, DISTRICT, AND LOCAL AUTHORITIES HAVING JURISDICATION OVER THE PROJECT AS WELL AS THOSE GREATER REQUIREMENTSINDICATED BY THE CONTRACT DOCUMENTS. NO PART OF THE CONTRACT DOCUMENTS MAY BE CONSTRUED TO REQUIRE OR PERMIT WORK CONTRARY TO A GOVERNING REGULATION. THE ARCHITECTURAL DRAWINGS ARE A PART OF A LARGER SET OF DRAWINGS WHICH, WHEN COMPLETE, CONSISTS OF ALL DRAWINGS LISTED BY THE INDEX OF DRAWINGS. THE WORK DESCRIBED BY THE DRAWINGS OF ANY ONE DISCIPLINE MAY BE AFFECTED BY THE WORK DESCRIBED ON DRAWINGS OF ANOTHER DISCIPLINE AND MAY REQUIRE REFERENCE TO THE DRAWINGS OF NOTHER DISCIPLINE. PARTIAL SETS OF DRAWINGS ARE INCOMPLETE AND SHOULD NOT BE DISTRIBUTED OR UTILIZED BY THE CONTRACTOR. IT IS THE CONTRACTOR'S RESPONSIBILITY TO REVIEW AND COORDINATE THE WORK OF ALL SUBCONTRACTORS, TRADES, AND SUPPLIERSWITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS BEFORE COMMENCING CONSTRUCTION, AND TO ASSURE THAT ALL PARTIES ARE AWARE OF ALL REQUIREMENTS, REGARDLESS OF WHERE THE REQUIREMENTS OCCUR IN THE CONTRACT DOCUMENTS, WHICH MIGHT AFFECT THE WORK OF THAT PARTY. AS PART OF THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE THE WORK OF ALL SUBCONTRACTORS, TRADES, AND SUPPLIERS, THE CONTRACTOR SHALL ENDEAVOR TO IDENTIFY AND NOTIFY THE ARCHITECT OF ANY CONFLICTS BETWEEN THE WORK OF DIFFERENT PARTIES AT THE EARLIEST POSSIBLE DATE SO AS TO ALLOW REASONABLE AND ADEQUATE TIME FOR THE CONFLICT TO BE RESOLVED WITHOUT DELAYING THE WORK. ALL DEVIATIONS FROM THAT WHICH IS REQUIRED BY THE CONTRACT DOCUMENTS MUST BE APPROVED IN ADVANCE BY THE ARCHITECT. THE ARCHITECTURAL DRAWINGS ESTABLISH AND COORDINATE THE FINISHED APPEARANCE AND EXACT LOCATION OF ALL EXPOSED ELEMENTS OF THE WORK OF ALL TRADES, INCLUDING THAT WORK WHICH IS ILLUSTRATED PRIMARILY ON DRAWINGS OF OTHER DISCIPLINES. LOCATIONS SHOWN ON OTHER DRAWINGS ARE SCHEMATIC, UNLESS OTHERWISE NOTED ON THE ARCHITECTURAL DRAWINGS. THE ARCHITECTURAL DRAWINGS TAKE PRECEDENCE FOR THE FINISHED APPEARANCE AND EXACT LOCATION OF ALL PARTS OF THE WORK. REFER TO THE ELECTRICAL, AND PLUMBING DRAWINGS FOR THE DETAILED DESIGN OF MECHANICAL, ELECTRICAL, AND PLUMBING SYSTEMS, OF WHICH PORTIONS MAY BE SHOWN ON THE ARCHITECTURAL DRAWINGS. ADDITIONAL SYMBOLS, NOT SHOWN OR DEFINED ON THE DRAWING "ARCHITECTURAL SYMBOLS", MAY OCCUR AND ARE DEFINED ON OTHER ARCH DRAWINGS. ROOM NAMES AND NUMBERS NOTED ON THE CONTRACT DRAWINGS MAY NOT REPRESENT THE FINAL ROOM NAMES AND NUMBERS TO BE INSTALLED UNDER THE SIGNAGE DRAWINGS. CONTRACTOR TO COORDINATE WITH OWNER FINAL NUMBER AND GRAPHICS. CAULKING NOTE: CAULKING CAVITY SHALL BE NO LARGER THAN 3/8" WITH BACKER ROD. Saugus Union School District - West Creek Academy KEYED CONSTRUCTION JOINT KEENE'S CEMENT PLASTER KNOCKDOWN KITCHEN HOOD KITCHEN HOOD EXHAUST FAN KITCHEN HOOD SUPPLY FAN KITCHEN KNOCKOUT KITCHEN SINK KILOVOLT KILOVOLT AMPERES KILOVOLT AMPERES REACTIVE KILOWATT KILOWATT HOUR OPERATION AND MAINTENANCE OUT TO OUT OVERALL OUTSIDE AIR OBSCURE ON CENTER OUTSIDE DIAMETER OVERFLOW DRAIN OUTSIDE FACE OVERFLOW OWNER FURNISHED CONTRACTOR INSTALLED OFFICE OWNER FURNISHED OWNER INSTALLED OVERHEAD POWER OVERHEAD TELEPHONE OPENING OPPOSITE OVERFLOW STORM DRAIN OUTSIDE SCREW AND YOKE OPEN TO CEILING SPACE OVERHEAD OXYGEN REVOLUTIONS PER MINUTE REDUCED PRESSURE BACKFLOW PREVENTER REFRIGERANT SUCTION RAIN WATER LEADERS SENSOR CONSTRUCTION DOCUMENTS KCJ KCP KD KH KHE KHS KIT KO KS KV KVA KVAR KW KWH O&M O to O OA OA OBSC OC OD OD OF OVFL OFC OFF OFOI OHP OHT OPG OPP OSD OS&Y OTCS OVHD OX RPM RPZ RS RWL , DLR Group inc., a California corporation, ALL RIGHTS RESERVED FAHRENHEIT FIRELINE FURNACE FIRE ALARM FRESH AIR FABRICATED HEIGHT HOOK ONE END HOSE BIB HANDICAP HOLLOW CORE HANDICAP BENCH HOT / CHILLED WATER RETURN HOT / CHILLED WATER SUPPLY HAND DRYER OR HAIR DRYER HARDBOARD HEADER HARDWOOD HARDWARE HOSE END VALVE HIGH INTENSITY DISCHARGE HOLLOW METAL HAND OFF AUTOMATIC HORIZONTAL HEAT PUMP HIGH PRESSURE HORSEPOWER HIGH PRESSURE STEAM RETURN HIGH PRESSURE SODIUM HIGH PRESSURE STEAM SUPPLY HANDRAIL HOUR HEADSTUD HOLLOW STRUCTURAL SECTION HIGH STRENGTH HEIGHT HEATING HEATER HIGH TEMP HOT WATER RETURN HIGH TEMP HOT WATER SUPPLY HUMIDIFIER HEATING VENTILATING UNIT HEATING VENTILATING AND AIR CONDITIONING DOMESTIC HOT WATER DOMESTIC HOT WATER RECIRCULATING LOW TEMP HOT WATER RETURN LOW TEMP HOT WATER SUPPLY HEAT EXCHANGER HERTZ JANITOR JUNCTION BOX JUNCTION JOIST JOINT FILLER BOARD JOINT NOISE CRITERIA NORMALLY CLOSED NURSE CALL NATIONAL ELECTRIC CODE NATIONAL ELECTRICAL MANUFACTURERS ASSN. NEUTRAL NOT IN CONTRACT NORMALLY OPEN NUMBER NITROUS OXIDE NOMINAL NEUTRAL SENSOR NOT TO SCALE © F F F FA FA FAB H H 1E HB HC HC HCB HCR HCS HD HDBD HDR HDWD HDWR HEV HID HM HOA HORIZ HP HP HP HPR HPS HPS HR HR HS HSS HSTR HT HTG HTR HTWR HTWS HUM HV HVAC HW HWC HWR HWS HX HZ JAN JB JCT JST JFB JT NC NC NC NEC NEMA NEUT NIC NO NO NO NOM NS NTS Interim Housing EAST EACH EXHAUST AIR ENTERING AIR TEMPERATURE EXPANSION BOLT ELECTRICAL CONTRACTOR ELECTRIC DUCT HEATER EACH END ENERGY EFFICIENCY RATIO EMERGENCY EYEWASH EMERGENCY EYEWASH/SHOWER EACH FACE EXHAUST FAN EFFICIENCY ELECTRICAL HEATER EXTERIOR INSULATION AND FINISH SYSTEM EXPANSION JOINT ELEVATION ELASTOMERIC ELECTRIC(AL) ELEVATOR EMERGENCY ESTIMATED MAXIMUM DEMAND ELECTRICAL METALLIC TUBING EMERGENCY MIXING VALVE ENCLOSURE ENTRANCE END OF MAIN DRIP ELECTRO-PNEUMATIC EXPLOSION PROOF EMERGENCY POWER OFF EPOXY RESIN FLOORING EQUAL EQUIPMENT EXHAUST REGISTER EMERGENCY SHOWER EXTRA STRONG EXTERNAL STATIC PRESSURE ESTIMATE EXPANSION TANK EACH WAY ELECTRIC WATER COOLER ELECTRIC WATER HEATER ENTERING WATER TEMPERATURE EXCAVATE EXHAUST EXISTING EXPANSION EXPOSED EXPLOSION EXTERIOR INDOOR AIR QUALITY IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE INTERCOM INSIDE DIAMETER INVERT ELEVATION ILLUMINATING ENGINEERING SOCIETY INSIDE FACE ISOLATED GROUND INTAKE HOOD ISOLATION JOINT IN JOIST SPACE INTERMEDIATE METAL CONDUIT INCH INCLUDE (ING) INSULATION INTERIOR IRON PIPE INDIRECT WASTE 28767 WEST HILLS DRIVE E EA EA EAT EB EC EDH EE EER EEW EEWS EF EF EFF EH EIFS EJ EL ELAS ELEC ELEV EMER EMD EMT EMV ENCL ENTR EOMD EP EP EPO ERF EQ EQUIP ER ES ES ESP EST ET EW EWC EWH EWT EXC EXH EXIST EXP EXP EXPL EXT IAQ IAW IBC IC ID IE IES IF IG IH IJ IJS IMC IN INC INSUL INT IP IW Revisions CONDENSER WATER CONDUIT COMBUSTION AIR CABINET CANTILEVER CAPACITY CASING CHALKBOARD CONDENSATE DRAIN CLOSED CIRCUIT TELEVISION COVER ELEVATION CEMENT CENTRIFUGAL CERAMIC CUBIC FEET CUBIC FEET PER HOUR CUBIC FEET PER MINUTE CORNER GUARD CHANNEL CAST IRON CURB INLET CAST IN PLACE CAST IRON PIPE CIRCULATING CONTROL JOINT CONTROL JOINT ABOVE CIRCUIT CIRCUIT BREAKER CENTERLINE CIRCUIT LINE CEILING CLOSET CLEAR CEILING MOUNTED CORRUGATED METAL PIPE CONCRETE MASONRY UNIT CLEAN OUT CONDUIT ONLY CARBON DIOXIDE COLUMN COMMON COMBINATION COMMUNICATIONS COMPOSITE COMPRESSOR UNIT COMPRESSIBLE CONCRETE CONFERENCE CONFIGURATION CONNECT CONNECTION CONSTRUCTION CONTINUOUS CONTRACTOR OR CONTRACT CONVECTOR CORRIDOR CONDENSER PUMP COVER PLATE CYCLES PER SECOND CARPET CONDENSER WATER RETURN DRAIN DEPTH DATA DRY BULB DECIBEL DEFORMED BAR ANCHOR DOUBLE DIRECT CURRENT DUST COLLECTOR DUMMY CONTROL JOINT PENNY (AS NAIL 10D) DIRECT DIGITAL CONTROL DEIONIZED WATER DEGREE DEPRESS(ION)(ED) DEPARTMENT DETENTION DRINKING FOUNTAIN DIESEL FUEL RETURN DIESEL FUEL SUPPLY DIESEL FUEL VENT DOOR GRILLE DUCT HEATER DISTILLED WATER DUCTILE IRON DIAMETER DIAGONAL DIFFUSER DIMENSION DISCONNECT SWITCH DISCONNECT DISCHARGE DISTRIBUTION DEAD LOAD DAMPER MOTOR DAMPER DOWN DOWNSPOUT NOZZLE DITTO DAMPROOFING DIFFERENTIAL PRESSURE SWITCH DOOR DRAIN DOWNSPOUT DISTILLED WATER DRY STANDPIPE DETAIL DUCT THRU ROOF DISHWASHER DRAWING DOWEL DRAWER DOUBLE EXTRA STRONG FACE BRICK FOOT CANDLE FLUTED CONCRETE MASONRY UNIT FLOOR CLEAN OUT FAN COIL UNIT FIRE DAMPER FLOOR DRAIN FIRE DEPARTMENT CONNECTION FOUNDATION FEEDER FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FINISH FLOOR FINISH FLOOR ELEVATION FIRE HYDRANT FIRE HOSE CABINET FIGURE FINISH FIXTURE FLOOR FLASHING FLEXIBLE FLUORESCENT FLOORING FULL LENGTH MIRROR FACTORY MUTUAL FIRE MAIN FLOW MEASURING EQUIPMENT FACE OF FINISH OPENING FACE OF CONCRETE FACE OF FINISH FUEL OIL FILL FACE OF MASONRY FUEL OIL RETURN FACE OF STUD FUEL OIL SUPPLY FUEL OIL VENT FACE OF WALL FIREPROOFING FIRE PUMP DISCHARGE FEET PER MINUTE FIRE RESISTIVE FRAME FIBERGLASS REINFORCED PANEL FLOOR SINK FLOW SWITCH FIRE/SMOKE DAMPER FOLDING SHOWER SEAT FEET (FOOT) FIN TUBE FLOW TRANSMITTER FOOTING FUTURE FIRE VALVE CABINET FABRIC WALL COVERING GRILLE NATURAL GAS GAUGE GALLON GALVANIZED GRAB BAR GENERAL CONTRACTOR GRADE CLEAN OUT GLAZED CONCRETE MASONRY UNIT GARBAGE DISPOSAL GENERAL GENERATOR GROSS FLOOR AREA GROUND FAULT INTERRUPTER GLASS FIBER REINFORCED CONCRETE GLYCOL-WATER HEATING RETURN GLYCOL-WATER HEATING SUPPLY GALVANIZED IRON GLUE LAMINATED GLASS GLASS MASONRY UNIT GROUND GOVERNMENT GALLONS PER HOUR GALLONS PER MINUTE GUARD RAIL GRADE GRILLE GLAVANIZED RIGID CONDUIT GLASS REINFORCED CONCRETE GLASS REINFORCED GYPSUM PLASTER GALVANIZED RIGID STEEL GASOLINE GATE VALVE GREASE WASTE GYPSUM WALL BOARD GYPSUM 75-15270-01 Issue Date; 03/31/2016 C C CA CAB CANT CAP CAS CBD CD CCTV CE CEM CENT CER CF CFH CFM CG CH CI CI CIP CIP CIRC CJ CJA CKT CKT BK CL CL CLG CLOS CLR CM CMP CMU CO CO CO2 COL COM COMB COMM COMP COMP COMPR CONC CONF CONFIG CONN CONN CONST CONT CONTR CONV CORR CP CP CPS CPT CR D D D DB DB DBA DBL DC DC DCJ d DDC DE DEG DEPR DEPT DET DF DFR DFS DFV DG DH DI DI DIA DIAG DIFF DIM DISC SW DISC DISCH DISTR DL DM DMPR DN DN DO OR " DPFG DPS DR DR DS DS DSP DTL DTR DW DWG DWL DWR DXS FB FC FCMU FCO FCU FD FD FDC FDN FDR FE FEC FF FFE FH FHC FIG FIN FIX FL FLASH FLEX FLUOR FLG FLM FM FM FME FO FO FOC FOF FOF FOM FOR FOS FOS FOV FOW FP FPD FPM FR FR FRP FS FS FSD FSS FT FT FT FTG FUT FVC FWC G G GA GAL GALV GB GC GCO GCMU GD GEN GEN GFA GFI GFRC GHR GHS GI GL GL GMU GND GOVT GPH GPM GR GR GR GRC GRC GRGP GRS GS GV GW GWB GYP SYMBOLS, ABBREVIATIONS and GENERAL NOTES BACK TO BACK BOILER BLOW OFF BALANCING COCK BURNISHED CONCRETE MASONRY UNIT BOARD BACK DRAFT DAMPER BETWEEN BACKFLOW PREVENTOR BELOW FLOOR BOILER FEED BUTTERFLY VALVE BREAK HORSE POWER BREAKER BUILDING LINE BUILDING BLOCK BLOCKING BULKHEAD BEAM BENCH MARK BOTTOM OF DUCT BOTTOM OF FOOTING BOTTOM BRIDGING BEARING BRACKET BASEMENT BATH TUB BRITISH THERMAL UNIT BRITISH THERMAL UNIT PER HOUR BUILT UP ROOFING BALL VALVE CORROSION RESISTANT COUNTERSINK COMBINATION SEWER CONDENSER WATER SUPPLY COUNTERSUNK CALCIUM SILICATE MASONRY UNIT COMBINATION STANDPIPE CONSTRUCTION JOINT CASEWORK COOLING TOWER CERAMIC TILE CURRENT TRANSFORMER CENTER COPPER CONDENSING UNIT CUBIC COMBINATION UNIT CABINET UNIT HEATER COLD WATER CONDOM VENDOR CHILLED WATER RETURN CHILLED WATER SUPPLY CUBIC YARD CYLINDER 0.1 B to B BBO BC BCMU BD BD BET BFP BFR BF BFV BHP BKR BL BLDG BLK BLKG BLKHD BM BM BOD BOF BOTT BRDG BRG BRKT BSMT BT BTU BTUH BUR BV CR CS CS CS CSK CSMU CSP CSTJ CSWK CT CT CT CTR CU CU CU CU CUH CW CV CWR CWS CY CYL East AIR CONDITIONING(ER) AMPERE COMPRESSED AIR AREA ALARM PANEL AUTOMATIC AIR VENT ANCHOR BOLT ACRYLONITRILE-BUTADIENE-STYRENE ACOUSTICAL CEILING ALTERNATING CURRENT AIR COOLED CONDENSER AIR COOLED CONDENSING UNIT ALUMINUM COMPOSITE MATERIAL ACOUSTIC ACCESS DOOR AREA DRAIN ADDITION OR ADDITIONAL ADJUSTABLE ADJACENT ADMINISTRATION AIR FILTER ABOVE FINISH FLOOR AUTHORITY HAVING JURISDICTION AIR HANDLING UNIT AREA INLET ALTERNATE ALUMINUM AMBIENT ANCHOR ACCESS PANEL ACOUSTICAL PANEL CEILING APPROXIMATE ACID RESISTING ARCHITECTURAL ASBESTOS ASPHALT AUTOMATIC ACID VENT AIR VENT AVERAGE ACID WASTE AMERICAN WIRE GAUGE ACOUSTICAL WALL PANEL Architecture Engineering Planning Interiors 3/31/2016 6:33:23 PM C:\Revit\75-15270-01_AR_2015_Cental_mfrey.rvt A/C A AMP A AAP AAV AB ABS AC AC ACC ACCU ACM ACST AD AD ADDN ADJ ADJT ADMIN AF AFF AHJ AHU AI ALT ALUM AMB ANCH AP APC APPROX AR ARCH ASB ASPH AUTO AV AV AV AW AWG AWP GENERAL SYMBOLS LEGEND NOTES 2. GATES IN THE FIRE LANE SHALL BE 20'-0" WIDE, CLEAR. WITH (2) 10'-0" LEAFS. 3. PROVIDE PAINTED LETTERING ON THE FIRE LANE IN WHITE TRAFFIC PAINT "NO PARKING - FIRE LANE". LETTERS TO BE 12" TALL. 4. PROVIDE 3" WIDE WHITE STRIPE DEFINING THE 20'-0" WIDE FIRE LANE THROUGH THE PLAY GROUND AREA. 5. FIRE DEPARTMENT VEHICULAR ACCESS ROADS MUST BE INSTALLED AND MAINTAINED IN A SERVICABLE MANNER PRIOR TO AND DURING THE TIME OF CONSTRUCTION. FIRE CODE 901.3 LEGEND; EXISTING FIRE LANE SCHOOL ADDRESS; 28767 WEST HILLS DRIVE, SANTA CLARITA 91354 (E) FIRE HYDRANT 28767 WEST HILLS DRIVE 1. FIRE LANE SHALL BE 20'-0" WIDE MINIMUM, ASPHALT PAVING CONSTRUCTION DOCUMENTS FIRE DEPARTMENT NOTES; BUILDING 'B' MEDIA A#03-110267 PLAYGR OUND G KIN PAR NO ANE EL - FIR (E) FIRE HYDRANT START LANE DROP OFF (E) FIRE LANE FIRE LANE MARKING, SEE NOTE #3 ANE EL - FIR (E) FIRE HYDRANT NO P ARK ING - BUILDING 'C-2' CLASSROOMS 2 STORY A#03-110267 (E) FIRE LANE WHITE STRIPING, SEE NOTE 4 SAFE DISPERSAL AREA CH LUN ER ELT SH NO CH LUN ER ELT SH ING RK PA NE E LA - FIR ING ARK NO P BUILDING 'C-1' CLASSROOMS 2 STORY A#03-110267 E LAN OFF OP DR FIRE LAN E Interim Housing G KIN PAR NO BUILDING 'C-3' CLASSROOMS 2 STORY A#03-110267 WHITE STRIPING, SEE NOTE #4 SITE PLAN - FIRE ACCESS NO PARKING BUILDING 'B' ADMIN A#03-110267 Saugus Union School District - West Creek Academy (E) FDC LOCATION CH LUN ER ELT H S 129' - 0" 129' - 7 1/4" PROPOSED RELOCATABLE CLASSROOM BUILDINGS FUTURE RELOCATABLE CLASSROOM BUILDING Revisions BUILDING 'A' MULTI-PURPOSE A#03-110267 FP.01 DAY CARE BUILDING 1 STORY A#03-112442 75-15270-01 Issue Date; 03/31/2016 (E) FIRE HYDRANT (E) FIRE HYDRANT SITE PLAN - FIRE ACCESS SCALE: 1" = 30'-0" NORTH 4/4/2016 3:57:01 PM C:\Revit\75-15270-01_AR_2015_Cental_mfrey.rvt ACCESSIBLE PATH OF TRAVEL , DLR Group inc., a California corporation, ALL RIGHTS RESERVED FUTURE © EXISTING Architecture Engineering Planning Interiors (E) FIRE HYDRANT LEGEND NOTES Construction Documents WEST CREEK ACADEMY 28767 WEST HILLS DRIVE SANTA CLARITA, CA 91355 PROJECT SITE HILL DR TITLE C-0.0 TITLE SHEET C-1.0 C-1.1 C-2.0 DEMOLITION PLAN EROSION AND SEDIMENT CONTROL PLAN FINE GRADING & DRAINAGE PLAN MC BE AN PK WY COPPER NO. 28767 W. Hills Dr. Santa Clarita, CA 91354 SHEET INDEX HA LL RA NC H E RD LD O D R 5 VICINITY MAP JOB ADDRESS: 28767 WEST HILLS DRIVE SANTA CLARITA, CA 91355 OWNER: CIVIL ENGINEER: PSOMAS 28480 AVENUE STANFORD, SUITE 200 SANTA CLARITA, CA 91355 TEL. (661) 219-6000 ATTN.: DAVID MARTIN PROPERTY LINE BOUNDARY RIGHT OF WAY CENTERLINE EXISTING EASEMENT MAXIMUM MINIMUM TOP OF CURB TOP OF WALL BACK OF WALK EDGE OF GUTTER EDGE OF PAVEMENT CURB AND GUTTER CONCRETE ASPHALT CONC PAVEMENT PAVEMENT CHAIN LINK FENCE TOP OF GRATE GRADE BREAK FINISHED GRADE FINISHED SURFACE FINISH FLOOR HIGH POINT LOW POINT FLOWLINE INVERT UTILITY JOINT TRENCH STORM DRAIN SANITARY SEWER WATER DW FW RW I / IRRI ICV G E T COM SL TS TSPB E-OH T-OH SDMH SSMH EMH E VLT EPB TMH T VLT TPB CB RCP FH FDC WV W VLT POC RMV RELO ABN RMN DOMESTIC WATER FIRE WATER RECLAIMED WATER IRRIGATION IRRIGATION CONTROL BOX GAS ELECTRIC TELEPHONE COMMUNICATION STREET LIGHT TRAFFIC SIGNAL TRAFFIC SIGNAL PULL BOX ELECTRIC (OVERHEAD) TELEPHONE (OVERHEAD) STORM DRAIN MANHOLE SEWER MANHOLE ELECTRIC MANHOLE ELECTRIC VAULT ELECTRIC PULL BOX TELEPHONE MANHOLE TELEPHONE VAULT TELEPHONE PULL BOX CATCH BASIN REINFORCE CONCRETE PIPE FIRE HYDRANT FIRE DEPT CONNECTION WATER VALVE WATER VAULT POINT OF CONNECTION REMOVE RELOCATE ABANDON REMAIN , DLR Group inc., California, ALL RIGHTS RESERVED PL BDRY R/W C/L EX/EXIST ESMT MAX MIN TC TW BW EG EP C&G CONC AC PVMT CLF TG GB FG FS FF HP LP FL INV UT JT SD SS W Civil Engineer 28480 Avenue Stanford, Suite 200 Santa Clarita, CA 91355 (661) 219-6000 (661) 775-2718 fax www.psomas.com © ABBREVATIONS: C-0.0 TITLE SHEET Plotted - 3/31/2016 2:45:26 PM :: Saved - 3/31/2016 2:43:02 PM :: V:\1DLR010200\ENGR\SHEETS\Interim Housing\C-0.0_TITL.dwg :: desiree.gravel SAUGUS UNION SCHOOL DISTRICT 24930 AVENUE STANFORD VALENCIA, CA 91355 Interim Housing Civil Design Plan N.T.S Saugus Union School Distrct - West Creek Academy TH E RY N CY RD Revisions 126 75-15270-01 Issue Date:03/31/2016 NE W HILLSBOROUGH PKWY 5 GRANDVIEW DR DECORO DR 3/31/2016 Construction Documents LEGEND NOTES N:4278918.41 E:4116292.69 28767 W. Hills Dr. Santa Clarita, CA 91354 1 CONSTRUCTION NOTES 1 PROPOSED ASPHALT PAVING LIMITS EXISTING LANDSCAPE AREA (GRASS) LEGEND EXISTING MAJOR CONTOUR N:4278876.01 E:4116321.07 1. 2. 3. N:4278823.19 E:4116457.25 CONSTRUCTION WASTE SHALL BE REDUCED BY 65%. CONSTRUCTION WASTE MUST BE HANDLED BY A CITY OF LOS ANGELES CERTIFIED HAULER. 100% OF EXCAVATED SOIL AND VEGETATION RESULTING FROM LAND CLEARING SHALL BE REUSED OR RECYCLED REFER TO GRN 5 FORM FOR ADDITIONAL REQUIREMENTS Civil Design Plan PROPOSED ASPHALT PAVING LIMITS N:4278763.00 E:4116433.92 C-1.0 DEMOLITION PLAN SCALE: 1" = 10' , DLR Group inc., California, ALL RIGHTS RESERVED N Civil Engineer 28480 Avenue Stanford, Suite 200 Santa Clarita, CA 91355 (661) 219-6000 (661) 775-2718 fax www.psomas.com © Plotted - 3/31/2016 3:41:18 PM :: Saved - 3/31/2016 3:35:14 PM :: V:\1DLR010200\ENGR\SHEETS\Interim Housing\C-1.0_DEMO.dwg :: desiree.gravel N:4278799.16 E:4116295.65 DEMOLITION PLAN PROPOSED ASPHALT PAVING LIMITS Interim Housing 1 Revisions MATERIAL CONSERVATION AND RESOURCE EFFICIENCY NOTES: 75-15270-01 Issue Date:03/31/2016 REMOVE EXISTING LANDSCAPE AREA (GRASS) Saugus Union School Distrct - West Creek Academy EXISTING MINOR CONTOUR 3/31/2016 28767 W. Hills Dr. Santa Clarita, CA 91354 Construction Documents LEGEND NOTES TC-1 WM-1 - STABILIZED CONSTRUCTION ENTRANCE / EXIT NOT TO SCALE SE-8 LEGEND: STABILIZED CONSTRUCTION ENTRANCE/EXIT WM-1 MATERIAL DELIVERY AND STORAGE WM-8 CONCRETE WASTE MANAGEMENT WM-9 SANITARY WASTE MANAGEMENT EROSION & SEDIMENT CONTROL PLAN , DLR Group inc., California, ALL RIGHTS RESERVED SCALE: 1" = 10' Interim Housing TC-1 Civil Design Plan GRAVEL BAG BARRIER EROSION & SEDIMENT CONTROL PLAN Civil Engineer 28480 Avenue Stanford, Suite 200 Santa Clarita, CA 91355 (661) 219-6000 (661) 775-2718 fax www.psomas.com © N SE-8 C-1.1 Plotted - 3/31/2016 3:54:34 PM :: Saved - 3/31/2016 3:46:58 PM :: V:\1DLR010200\ENGR\SHEETS\Interim Housing\C-1.1_EROS.dwg :: desiree.gravel TEMPORARY CONSTRUCTION FENCE Revisions TC-1 75-15270-01 Issue Date:03/31/2016 WM-9 Saugus Union School Distrct - West Creek Academy SE-8 WM-8 3/31/2016 JOIN EXISTING Construction Documents LEGEND NOTES 1 CONSTRUCT 2.5" A.C. PAVEMENT OVER 4" CLASS 2 AGGREGATE BASE PER DETAIL 1 2 INSTALL RAMP PER MOBILE MODULAR DSA FOUNDATION PLANS 3 LANDSCAPE AREA TO REMAIN IN PLACE 4 EXTEND PAVING AT 2:1 SLOPE TO MEET EXISTING LANDSCAPE SURFACE (GRASS) 5 PROPOSED TREE WELL 6 MATCH PROPOSED PAVING TO EXISTING MOW STRIP 8.00 ' 1 28767 W. Hills Dr. Santa Clarita, CA 91354 CONSTRUCTION NOTES 1 1 LEGEND EXISTING MINOR CONTOUR PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR 2 4 1 1 1344.10 FS 1.7% 2 JOIN EXISTING % 1.8 2 1344.36 FS PROPOSED MOBILE MODULAR BUILDING 1344.45 FS 1344.46 FS PROPOSED MOBILE MODULAR BUILDING 1344.54 FS PROPOSED MOBILE MODULAR BUILDING 1344.64 FS FUTURE MOBILE MODULAR BUILDING PAD 1345.20 FS 1345.21 FS 5 4 0.9 % 1345.07 FS 1345.12 FS 1 1345.33 FS 5 1345.35 FS 1.1 % 5 1345.47 FS 5 1345.36 FS 1.5% 1 6 1345.57 FS PROPOSED FENCE 1345.66 FS C-2.0 FINE GRADING AND DRAINAGE PLAN SCALE: 1" = 10' , DLR Group inc., California, ALL RIGHTS RESERVED N Civil Engineer 28480 Avenue Stanford, Suite 200 Santa Clarita, CA 91355 (661) 219-6000 (661) 775-2718 fax www.psomas.com © Plotted - 3/31/2016 4:57:26 PM :: Saved - 3/31/2016 4:44:09 PM :: V:\1DLR010200\ENGR\SHEETS\Interim Housing\C-2.0_GRAD_FINE.dwg :: desiree.gravel 6 Revisions 0.9% NOT TO SCALE 1 1345.09 FS 1345.04 FS 1 1344.56 FS 1345.08 FS 1 1344.40 FS TYPICAL ASPHALT SECTION Interim Housing 1344.95 FS AGGREGATE BASE FINE GRADING & DRAINAGE PLAN PROPOSED FENCE 4 % 1344.36 FS 1344.83 FS 4" EXISTING IN-SITU 12" MATERIAL - 95% RECOMPACTED % PROPOSED MOBILE MODULAR BUILDING 1 1.9 4 AC PAVEMENT 2 0.3 % 1344.27 FS 2.5" Civil Design Plan 1344.26 FS 2.0 1344.18 FS 75-15270-01 Issue Date:03/31/2016 1.7 % PROPOSED BUILDING OUTLINE Saugus Union School Distrct - West Creek Academy EXISTING MAJOR CONTOUR 1343.94 FS 3/31/2016 CODE ANALYSIS CALCULATION NOTES; 1. CHAINLINK FENCING, BETWEEN BUILDINGS, TYP. BUILDING 'A' CLASSROOM DOOR, TYP. ACTUAL STORIES GROSS SQUARE FEET ALLOWABLE HEIGHT PER CBC TABLE 503 TYPE V-B 1 1 1080 40' 12' 1 1 1080 TYPE V-B 1 1 1080 40' 40' 12' BUILDING 'C' E E TYPE V-B BUILDING 'D E TYPE V-B TOTAL BUILDING SQUARE FEET 1 1 1080 40' 12' THE ACCESSIBLE PATH OF TRAVEL (POT) IDENTIFIED IN THESE CONSTRUCTION DOCUMENTS IS COMPLIANT WITH THE CURRENT APPLICABLE CALIFORNIA BUILDING CODE ACCESSIBILITY PROVISIONS FOR PATH OF TRAVEL REQUIREMENTS FOR ALTERATIONS, ADDITIONS ANDS STRUCTURAL REPAIRS. AS PART OF THE DESIGN OF THIS PROJECT, THE POT WAS EXAMINED AND ANY ELEMENTS, COMPONENTS OR PORTIONS OF THE POT THAT WERE DETERMINED TO BE NON-COMPLIANT A) HAVE BEEN IDENTIFIED AND B) THE CORRECTIVE WORK NECESSARY TO BRING THEM INTO COMPLIANCE HAS BEEN INCLUDED WITHIN THE SCOPE OF THIS PROJECT'S WORK THROUGH DETILS, DRAWINGS, AND SPECIFICATIONS INCORPORATED INTO THESE CONSTRUCTION DOCUMENTS. ANY NON-COMPLIANT ELEMENTS, COMPONENTS OR PORTIONS OF THE POT THAT WILL NOT BE CORRECTED BY THIS PROJECT BASED ON VALUATION THRESHOLD LIMITATIONS OR A FINDING OF UNREASONABLE HARDSHP NARE SO INDICATED IN THESE CONSTRUCTION DOCUMENTS. DURING CONSTRUCTION, IF POT ITEMS WITHIN THE SCOPE OF THE PROJECT REPRESENTED AS CODE COMPLIANT ARE FOUND TO BE NON-CONFORMING BEYOND REASONABLE CONSTRUCTION TOLERANCES, THEY SHALL BE BROUGHT INTO COMPLIANCE WITH THE CBC AS PART OF THIS PROJECT BY MEANS OF A CONSTRUCTION CHANGE DOCUMENT. 12' 4,320 RELOCATABLES DETAILS INDEX North Elevation 4 2. 'PC' NUMBER BUILDING TYPE SIZE 'A' NUMBER BUILDING 'A' 04-103659 4-101244 CLASSROOM 24 X 40 BUILDING 'B' 04-101244 4-104778 CLASSROOM 24 X 40 BUILDING 'C' 04-101244 4-104778 CLASSROOM BUILDING 'D 04-101244 4-104778 CLASSROOM 24 X 40 24 X 40 MANUFACTURER MOBILE MODULE MOBILE MODULE 50 MOBILE MODULE 50 50 50 MOBILE MODULE 3 RELOCATABLE BUILDING, TYP. CP1.1 BUILDING ANALYSIS; OCCUPANCY GROUP; E CONSTRUCTION TYPE; TYPE V-B AUTOMATIC SPRINKLER SYSTEM; NO (4) PORTABLE BUILDINGS, CONSIDERED AS (1) BUIDLING PER CBC 503.1.2. GROSS SQUARE FOOTAGE OF 1080 SF PER PORTABLE X (4) PORTABLES = 4,320 SF. CBC TABLE 503, MAXIMUM ALLOWABLE SF FOR A TYPE V-B, GROUP 'E' BUILDING IS = 9,500 SF. LIVE LOAD 3. SCALE: 1/8" = 1'-0" CP1.1 DESIGN PROFESSIONAL IN GENERAL RESPONSIBLE CHARGE STATEMENT; ACTUAL HEIGHT E BUILDING 'B' ACCESSIBLE LANDING & RAMP CONSTRUCTION ALLOWABLE STORIES TYPE PER CBC TABLE 503 DETERIORATION OR EXISTING NON-COMPLIANT CONSTRUCTION; IF ANY CONDITION IS DISCOVERED WHICH, IF LEFT UNCORRECTED, WOULD MAKE THE BUILDING NON-COMPLIANT WITH THE REQUIREMENTS OF THE EDITION OF THE CBC IN FORCE AT THE TIME OF ORIGINAL CONSTRUCTION, THE CONDITION MUST BE CORRECTED IN ACCORDANCE WITH CURRENT CODE REQUIREMNTS. A CHANGE ORDER, OR A SEPERATE SET OF PLANS AND SPECIFICATIONS DETAILING AND SPECIFYING THE REQUIRED REPAIT WORK SHAL BE SUBMITTED TO AND APPROVED BY DSA BEFOR PROCEEDING WITH THE REPAIR WORK. CODE ANALYSIS CALCULATION SCALE: 1/8" = 1'-0" 4. TEMPORARY BUILDINGS THE RELOCATABLE BUILDINGS INCLUDED IN THIS PROJECT SCOPE OF WORK ARE TEMPORARY. THE MAXIMUM USE OF THE BUILDINGS WILL BE THREE (3) YEARS IN ACCORDANCE WITH CHAPTER 9, PART 2, TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR). CBC 903.2.19.1, EXCEPTION 1, FIRE SPRINKLERS ARE NOT REQUIRED IN RELOCATABLE BUILDINGS ON TEMPORARY FOUNDATIONS WHEN THEY ARE SITED WITH THE INTENT THAT THEY WILL BE ON THE SITE FOR LESS THAN THREE YEARS. 5. CONSTRUCTION DOCUMENTS OCCUPANCY GROUP BUILDING MODULE IDENTIFICATION 28767 WEST HILLS DRIVE RELOCATABLE BUILDING, TYP THE MANUFACTURER OR BUILDER SHALL PLACE TWO PERMANENT METAL IDENTIFICATION LABELS ON EACH BUILDING MODULE, ONE MECHANICALLY FASTENED AND VISIBLE FROM THE EXTERIOR AND THE OTHER MECHANICALLY FASTENED TO THE INTERIOR FRAME ABOVE THE CEILING, AT THE END OF THE MODULE. THE LABELS SHALL SHOW THE DSA APLICATION NUMBER AND CBC EDTITION UNDER WHICH THE BUILDING CONSTRUCTION WAS AUTHORIZED, THE MANUFACTURER OR BUILDER'S NAME, THE SERIAL NUMBER, THE DESIGN CLIMATE ZONES (PER TITLE 24, PART 6, SECTION 143(a)8), THE DESIGN LIVE LOADS FOR THE ROOF AND FLOOR FRAMING, THE DESIGN WIND SPEED AND EXPOSURE CATEGORY, AND SEISMIC DESIGN PARAMETER Ss. THE LOCATION OF THE IDENTIFICATION LABELS SHALL BE SHOWN ON THE BUILDING PLANS. 6. EXISTING TREES EXISTING TREES ARE TO BE PROTECTED IN PLACE. PROVIDE 8'-0" DIAMETER OPENING (TREEWELL) IN THE ASPHALT PAVING. COORDINATE EXACT SIZE AND LOCATION OF TREE WELL WITH OWNER. CARE TO BE TAKEN TO NOT DAMAGE TREE ROOTS. 7. CHAINLINK GATE PROVIDE 4' WIDE X 6' HIGH CHAIN LINK GATE WITH A PAD LOCK. GATE PROVIDES ACCESS TO ELECTRICAL AND MECHANICAL EQUIPMENT FOR THE RELOCATABLE BUILDING. NO STUDENT ACTIVITIES IN THIS AREA. POT, SEE AS1.00 FOR CONTINUATION WALKWAY ASPHALT PAVING (E) PLANTING (GRASS PLAYING FIELD) 8' - 0". JOIN FLUSH (E) ASPHALT PLAY GROUND STRENGTHED FOR FIRE TRUCK ACESS (E) WALKWAY ASPHALT PAVING (E) PLANTING (GRASS PLAYING FIELD) CP1.1 4 CODE PLAN UPPER LANDING ASPHALT PAVING 16 6' - 0" ACCESSIBLE RAMP TYP. 12' - 0" FF 1344.72' FF 1344.69' PORTABLE BUILDING 'B' GROSS SF 1080 TYPE V-B DSA # 04-106743 OCC. 'E' PORTABLE BUILDING 'C' GROSS SF 1080 TYPE V-B DSA # 04-106743 OCC. 'E' 2' - 0" 2' - 0" 24' - 0" 24' - 0" PORTABLE BUILDING 'D' GROSS SF 1080 TYPE V-B DSA # 04-106743 OCC. 'E' FUTURE MODULAR CLASSROOM 2' - 0" 24' - 0" 24' - 0" 8' - 0" 86' - 0" FF1344.63' 40' - 0" PORTABLE BUILDING 'A' GROSS SF 1080 TYPE V-B DSA # 04-103659 OCC. 'E' FF 1344.66' 5 35' - 6" 3'-0" CHAINLINK GATE, SE NOTE 7 CP1.1 EQUIPMENT PAD MECHANICAL YARD TY LINE PROPER 4/4/2016 3:57:00 PM C:\Revit\75-15270-01_AR_2015_Cental_mfrey.rvt 27' - 6" 8' -0" DIA. TREE WELL AT (E) TREES, TYP. SEE NOTE #6 26 AS1.01 Revisions AS1.01 CP1.1 JOIN FLUSH 1 CP1.1 NORTH ENLARGED SITE PLAN - CODE ANALYSIS SCALE: 1/8" = 1'-0" Architecture Engineering Planning Interiors ACCESSIBLE PATH OF TRAVEL, SEE NOTES ON AS1.00 75-15270-01 Issue Date; 03/31/2016 (E) ASPHALT PLAY GROUND Interim Housing 41' - 6". JOIN FLUSH Saugus Union School District - West Creek Academy SCALE: 1/8" = 1'-0" , DLR Group inc., a California corporation, ALL RIGHTS RESERVED CP1.1 FOR BUILDINGS THAT ARE MANUFACTURED IN-PLANT, THE IN-PLANT INSPECTOR IS TO ATTACH A VERIFIED REPORT INSIDE EACH BUILDING, WHICH SHALL INDICATE THE MANUFACTURER'S NAME AND THE SERIAL NUMBER FOR EACH BUILDING MODULE AS WELL AS THE DSA FILE AND APPLICATION NUMBERS. South Elevation © 5 DSA APPROVAL NUMBERS DSA FILE 19-97 03-110267 CERTIFIED 03-111246 03-112442 03-116701 2/29/2016 CERTIFIED CERTIFIED PROJECT IS ON-GOING CONSTRUCTION OF M.P., ADMIN/MEDIA, & (3) C.R.BUILDINGS, TRELLIS, WALKWAY STRUCTURE, & SITEWORK. 6/22/2012 SHADE STRUCTURES, LUNCH SHELTERS, SHADE CANOPIES 1/05/2016 DAY CARE BUILDING (AS OF MARCH 2016) 1. PATH OF TRAVEL: PATH OF TRAVEL (P.O.T.), AS INDICATED, IS A COMMON BARRIER FREE ACCESS ROUTE WITHOUT ANY ABRUPT VERTICAL CHANGES EXCEEDING 1/2" BEVELED AT 1:2 MAXIMUM SLOPE, EXCEPT THAT LEVEL CHANGES DO NOT EXCEED 1/4" VERTICAL AND IS AT LEAST 48" WIDE. THE PATH SURFACE IS SLIP RESISTANT, STABLE, FIRM AND SMOOTH. PASSING SPACES (1133B.7.1) AT LEAST 60"X60" ARE LOCATED NOT MORE THAN 200" APART. THE CROSS-SLOPE DOES NOT EXCEED 2% AND SLOPE IN THE DIRECTION OF TRAVEL AND IS LESS THAN 5% UNLESS OTHERWISE INDICATED. (POT) SHALL BE MAINTAINED FREE OF OVERHANGING OBSTRUCTIONS TO 80" MINIMUM (1133B.8.2) AND PROTRUDING OBJECTS GRATER THAN 4" PROJECTION FROM WALL AND ABOVE 27" AND LESS THAN 80" (1133B.8.6). 2. WALKS AND SIDEWALKS SHALL HAVE A CONTINUOUS COMMON SURFACE, NOT INTERRUPTED BY STEPS OR BY ABRUPT CHANGES IN LEVEL EXCEEDING 1/2". CONSTRUCTION DOCUMENTS LEGEND NOTES 4. WHEN CHANGES IN LEVEL NOT EXCEEDING 1/2" OCCUR, THEY SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2, EXCEPT THAT LEVEL CHANGES NOT EXCEEDING 1/4" MAY BE VERTICAL. 5. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE EXCEEDING 1/2" SHALL COMPLY WITH THE REQUIREMENTS FOR CURB RAMPS. 6. WALK AND SIDEWALK SURFACES SHALL BE SLIP-RESISTANT AS FOLLOWS: A. SURFACES WITH A SLOPE LESS THAN 6% GRADIENT SHALL BE AT LEAST A SLIP-RESISTANT AS THAT DESCRIBED AS A MEDIUM BROOM FINISH. B. SURFACES WITH A SLOPE OF 6% OR GREATER GRADIENT SHALL BE SLIP-RESISTANT WITH A HEAVY BROOM FINISH. PARKING LOT 'A', A#03-110267 STALLS 37 STANDARD ACCESIBLE STALLS 1 VAN ACCESSIBLE STALLS 1 TOTAL STALLS 39 28767 WEST HILLS DRIVE 3. WALKS AND SIDEWALKS SHALL BE 48" MINIMUM IN WIDTH, 60" IS PREFERRED. 7. WHEN THE SLOPE IN THE DIRECTION OF TRAVEL OF ANY WALK EXCEEDS 1 VERTICAL TO 20 HORIZONTAL, IT SHALL COMPLY WITH THE PROVISIONS OF SECTION 1133B.5 AS A PEDESTRIAN RAMP. STANDARD ACCESSIBLE STALL, A#03-110267 8. WALK AND SIDEWALK SURFACE CROSS SLOPES SHALL NOT EXCEED 1:50 (2% MAX.). VAN ACCESSIBLE STALL, A#03-110267 9. ALL WALKS WITH CONTINUOUS GRADIENTS SHALL HAVE LEVEL AREAS AT LEAST 5' IN LENGTH AT INTERVALS OF AT LEAST EVERY 400'. T PO CURB-CUT, A#03-110267 11. LEVEL AREA OF WALK SHALL EXTEND 24" TO THE SIDE OF THE STRIKE EDGE OF A DOOR OR GATE THAT SWINGS TOWARD THE WALK. SEE 31/CP4.1. 12. WALKS, SIDEWALKS, AND PEDESTRIAN WAYS SHALL BE FREE OF GRATINGS WHENEVER POSSIBLE. FOR GRATINGS LOCATED IN THE SURFACE OF ANY OF THESE AREAS, GRID OPENINGS IN GRATING SHALL BE LIMITED TO THE DIRECTION OF TRAFFIC FLOW. IF GRATINGS HAVE ELONGATED OPENINGS, THEY SHALL BE PLACED SO THAT THE LONG DIMENSION IS PERPENDICULAR TO THE DOMAIN DIRECTION OF TRAVEL. T PO BUILDING 'B' MEDIA A#03-110267 POT PLAYGR SR T PO 13. (E) PATH OF TRAVEL. SEE PER A# 03-110267 OUND POT R W MR T PO T PO POT T PO PO T (E) ASPHALT PLAYGROUND T PO BUILDING 'B' ADMIN A#03-110267 T PO T PO BR T PO T PO BUILDING 'C-3' CLASSROOMS 2 STORY A#03-110267 Architectural Site Plan POT SR (E) ASPHALT RUNNING TRACK PO T SR POT GR (E) PATH OF TRAVEL (SEE NOTE #13) POT POT SR BR PO T POT NS RE ILD CH E LAN OFF OP DR POT T PO BUILDING 'C-2' CLASSROOMS 2 STORY A#03-110267 PO T SAFE DISPERSAL AREA CH LUN ER ELT SH (E) ASPHALT WALKWAY, TYP. BR BUILDING 'C-1' CLASSROOMS 2 STORY A#03-110267 MR GR NO ING RK PA CH LUN ER ELT H S PO T 1 CP1.1 (E) TURF SR DAY CARE BUILDING 1 STORY A#03-112442 ASPHALT RUNNING TRACK BUILDING 'A' MULTI-PURPOSE A#03-110267 CH LUN ER ELT SH AS1.00 POT T PO Interim Housing SR JOIN FLUSH PO T - LUNCH SHELTER A#03-111246 Revisions NO PARKING GR 75-15270-01 Issue Date; 03/31/2016 LANE DROP OFF START Saugus Union School District - West Creek Academy 10. WALKS SHALL BE PROVIDED WITH A LEVEL AREA NOT LESS THAN 60" BY 60" AT A DOOR OR GATE THAT SWINGS TOWARD THE WALK, AND NOT LESS THAN 48" WIDE BY 44" DEEP AT A DOOR OR GATE THAT SWINGS AWAY FROM THE WALK. SEE 31/CP4.1. JOIN FLUSH, TYP. ASPHALT PAVING, SEE CIVIL JOIN FLUSH SHADE STRUCTURE, A#03-110267 155 '- PATH OF TRAVEL 7" POT WR FUTURE RELOCATABLE BUILDING LOCATION CP1.1 4 POT CP1.1 LEGEND EXISTING ACCESSIBLE PATH OF TRAVEL PARKING LOT 'C', A#03-110267 STALLS 79 STANDARD ACCESIBLE STALLS 3 VAN ACCESSIBLE STALLS 1 TOTAL STALLS 83 B.R. (E) ACCESSIBLE BOYS RESTROOM A# 03-1110267 G.R. (E) ACCESSIBLE GIRLS RESTROOM A# 03-1110267 M.R. (E) ACCESSIBLE MENS RESTROOM A# 03-1110267 SITE PLAN SCALE: 1" = 30'-0" NORTH 4/4/2016 3:56:59 PM C:\Revit\75-15270-01_AR_2015_Cental_mfrey.rvt FUTURE W.R. (E) ACCESSIBLE WOMENS RESTROOM A# 03-1110267 S.R. (E) ACCESSIBLE STAFF RESTROOM A# 03-1110267 , DLR Group inc., a California corporation, ALL RIGHTS RESERVED AS1.01 © 5 26 Architecture Engineering Planning Interiors 6' CHAINLINK FENCING, SEE 35/AS1.01 12 13 14 15 16 NOTE; 1. MAXIMUM SLOPE OF WALKWAYS AND LANDINGS TO BE 2% IN ANY DIRECTION ASPHALT WALKWAY 6' - 0" LANDING ASPHALT LANDING JOIN FLUSH, TYP. JOIN FLUSH, TYP. UP JOIN FLUSH 5' - 0" LANDING RAMP AND HANDRAILS PER PC DRAWINGS UP UP AS1.01 21 22 23 24 25 28767 WEST HILLS DRIVE BUILDING FOOT-PRINT 16 CONSTRUCTION DOCUMENTS 11 RAMP-LANDING, TYPICAL SCALE: 1/4" = 1'-0" 26 CONCRETE HOUSE-KEEPING PAD NOTE; 1. COORDINATE SIZE OF EQUIPMENT PAD WITH EQUIPMENT SHOP DRAWINGS. 2. EQUIPMENT PAD, 6" THICK CONCRETE SLAB ON GRADE, 3000 PSI CONCRETE WITH #4 BARS 2 12" O.C. EACH WAY EQUIPMENT PAD 31 32 33 34 35 SCALE: 1/4" = 1'-0" 36 KNUCKLED FABRIC TOP AND BOTTOM 3/8" O.C. TENSION ROD (TYP.) AT GATE, END, PULL AND CORNER POSTS POST CAP 1.66" O.D. TOP RAIL 2.875" O.D. LINE POST NOTE: 1.) PROVIDE A DOUBLE OR SINGLE GATE, PER PLAN. 2.) ALL CHAIN-LINK FENCE SHALL BE PVC-COATED AT BUILDING 'H' GATE ENCLOSURES ONLY. 3.) ADD SLATS AT BUILDING 'H' GATE ENCLOSURES ONLY. SEE PLANS SEE PLANS 9 GA. CHAINLINK FABRIC HEIGHT 6'-0" 3" O.D. END PULL AND CORNER POSTS 42 43 44 45 46 51 52 53 54 55 56 3/31/2016 6:33:24 PM C:\Revit\75-15270-01_AR_2015_Cental_mfrey.rvt AS1.01 41 Interim Housing SCALE: 1/2" = 1'-0" CANE BOLT WITH SLEEVE; STEEL PIPE SLEEVE DOWN 6" BELOW GRADE AT BOTH CLOSED AND FULLY OPEN POSITION. SET IN 6" ∅ BY 18" DEEP CONC. FTG. WHEN LOCATED IN ASPHALT PAVING Revisions CHAINLINK FENCE W/GATE TENSION WIRE ANCHOR AT EACH POST 1/4" WIRE Architecture Engineering Planning Interiors AS1.01 MIN. GAP REQ.: 1" GAP FOR LEAFS LESS THAN 8'-0"; 2" GAP FOR LEAFS GREATER THAN 8'-0" FORK LATCH 75-15270-01 Issue Date; 03/31/2016 . 10' MAX. 35 GATES WHERE SHOWN SITE DETAILS 12" O.D. CONC. FTG. (TYP.) 6" .2'-8" 2" MAX. , DLR Group inc., a California corporation, ALL RIGHTS RESERVED AS1.01 © 26 Saugus Union School District - West Creek Academy 4' - 6" 10' - 6" NOTES SYMBOLS BAS BJ BKR BLDG BMS BUILDING AUTOMATION SYSTEM BONDING JUMPER BREAKER BUILDING BUILDING MANAGEMENT SYSTEM DB DC DISC DIV DP DW DECIBEL DIRECT CURRENT DISCONNECT SPECIFICATION DIVISION DISTRIBUTION PANELBOARD DISHWASHER EA ECB ECS ELEC EMD EP EQ EQUIP ER EWC EXT EACH ENCLOSED CIRCUIT BREAKER EMERGENCY COMMUNICATIONS SYSTEM ELECTRIC(AL) ESTIMATED MAXIMUM DEMAND EXPLOSION PROOF EQUAL EQUIPMENT EXISTING (TO BE) RELOCATED ELECTRIC WATER COOLER EXTERIOR FA FAA FACP FC FLA FLUOR FS FSD FT FIRE ALARM FIRE ALARM ANNUNCIATOR FIRE ALARM CONTROL PANEL FOOT CANDLE FULL LOAD AMPS FLUORESCENT FLOW SWITCH FIRE SMOKE DAMPER FEET (FOOT) 3. IN ADDITION TO DEVICES SHOWN, SEE SCHEDULE SHEETS FOR CONNECTIONS TO ALL MECHANICAL EQUIPMENT. 7. HOMERUNS SHALL NOT EXCEED THREE CURRENT CARRYING CONDUCTORS OR ADJUST FOR CODE REQUIRED DERATING. 9. ALL PANELS SHALL COME WITH PANEL SCHEDULE DIRECTORY LOCATED INSIDE THE PANEL. ALL SWITCHBOARD CIRCUITS SHALL BE LABELED. GENERAL LIGHTING NOTES (TYPICAL ALL LIGHTING SHEETS) JB JUNCTION BOX KAIC KV KVA KW THOUSAND AMPERE INTERRUPTING CURRENT KILOVOLT KILOVOLT AMPERES KILOWATT 6. FIXTURES DENOTED WITH LOWER CASE LETTERS SHALL BE CONTROLLED BY SWITCHES DENOTED WITH THE SAME LOWER CASE LETTER IN EACH ROOM. LT LTG LIGHT LIGHTING RECEP RECEPTACLE SCCR SD SEC SIM SPD SWBD SHORT CIRCUIT CURRENT RATING SMOKE DAMPER SECONDARY SIMILAR SURGE PROTECTION DEVICE SWITCHBOARD TBB TC TGB TMGB TO TR TS TV TYP TELECOMMUNICATIONS BONDING BACKBONE TIME CLOCK TELECOMMUNICATIONS GROUNDING BUSBAR TELECOMMUNICATIONS MAIN GROUNDING BUSBAR TELECOMMUNICATIONS OUTLET TELECOMMUNICATIONS ROOM TAMPER SWITCH TELEVISION TYPICAL UG UNO UNDERGROUND UNLESS NOTED OTHERWISE V VA VFD VOLT VOLT-AMPERE VARIABLE FREQUENCY DRIVE W WA WG WP WIRE TELECOMMUNICATIONS WORK AREA WIRE GUARD WEATHER-PROOF (NEMA 3R) XFMR TRANSFORMER S LIGHTING FIXTURE ON EMERGENCY SYSTEM S 2 SWITCH, DOUBLE POLE 3 SWITCH, 3-WAY 4 SWITCH, 4-WAY D 2. PROVIDE #10AWG MINIMUM CONDUCTORS FOR ALL EXTERIOR LIGHTING CIRCUITS. 3. SEE ARCHITECTURAL BUILDING ELEVATIONS FOR LOCATION OF BUILDING MOUNTED EXTERIOR LIGHT FIXTURES. 1. TELECOMMUNICATION, AUDIO/VISUAL, SECURITY AND FIRE ALARM DESIGN ARE DONE BY OTHERS. REFER TO ARCHITECTURAL, TELECOMMUNICATION, AUDIO/VISUAL, SECURITY AND FIRE ALARM DRAWINGS FOR ELECTRICAL REQUIREMENTS. CONTRACTOR SHALL PROVIDE AND INSTALL RELEVANT SCOPE OF WORK. 2. PROVIDE THE CIRCUIT FOR THE DEVICES AND EQUIPMENT FROM DIVISION 27 AND 28 THAT REQUIRES 120V/208V OR 277V/480V POWER SUPPLY. PROVIDE CIRCUIT BREAKER, CONDUIT AND WIRES. 3. PROVIDE CONTROL CONDUITS FOR THE DEVICES AND EQUIPMENT FROM DIVISION 27 AND 28. LOW VOLTAGE SIGNAL/CONTROL CABLES SHALL BE PROVIDED BY OTHERS. 7. EXIT SIGNS SHALL NOT BE USED AS J-BOXES. PROVIDE J-BOX FOR EVERY EXIT SIGN. MICROPHONE OUTLET, WALL SR MONITOR SPEAKER RECEPTACLE, WALL X SWITCH, EXPLOSION-PROOF K LOW VOLTAGE SWITCH TO HAVE LOCKABLE PLASTIC COVER. WALL WASHER S HIGH BAY LIGHTING FIXTURE S WALL MOUNTED LIGHTING FIXTURE S S S S N TS LC PHOTOELECTRIC CELL LC LIGHTING CONTACTOR BAT REMOTE EMERGENCY BATTERY PACK LOW VOLTAGE WIRELESS LIGHTING CONTROLLER INTERFACE. OS OCCUPANCY SENSOR VS VACANCY SENSOR FACP FILE ALARM CONTROL PANEL I FAA FILE ALARM ANNUNCIATOR PANEL P NEP WALL MOUNTED LIGHTING CONTROL DEVICES: MOUNT 94-INCHES AFF, UNO OS OCCUPANCY SENSOR VS VACANCY SENSOR N.A.C. EXTENDER PANEL F MANUAL FIRE ALARM PULL STATION F FIRE ALARM BELL F FIRE ALARM HORN F FIRE ALARM VISUAL WARNING SIGNAL F FIRE ALARM BELL WITH VISUAL WARNING SIGNAL F FIRE ALARM HORN WITH VISUAL WARNING SIGNAL F MINI FIRE ALARM HORN WITH VISUAL WARNING SIGNAL F FIRE ALARM SPEAKER WITH VISUAL WARNING SIGNAL D (TYPICAL ALL DEMOLITION SHEETS) 1. ALL FIRE ALARM DEVICES ARE TO BE LEFT IN PLACE AND SUPPORTED UNTIL NEW FIRE ALARM IS INSTALLED. ELECTRICAL SHEET LIST SHEET NUMBER SHEET NAME I SMOKE DETECTOR-PHOTOELECTRIC TYPE (D = DUCT) SMOKE DETECTOR - IONIZATION TYPE P SMOKE DETECTOR - PHOTOELECTRIC TYPE D HEAT DETECTOR RATE-OF-RISE AND FIXED TEMPERATURE, 135 F HEAT DETECTOR, RATE-OF-RISE AND FIXED TEMPERATURE, 200 F HEAT DETECTOR, FIXED TEMPERATURE ONLY, 135 F HEAT DETECTOR, FIXED TEMPERATURE ONLY, 200 F S SPRINKLER SYSTEM ELECTRONIC BELL ALARM D FIRE ALARM MAGNETIC DOOR HOLDER L REMOTE INDICATOR LAMP F FIRE ALARM SPEAKER, FLUSH IN CEILING F FIRE ALARM SPEAKER WITH VISUAL WARNING SIGNAL, CEILING OSY OS&Y VALVE F FIRE ALARM VISUAL WARNING SIGNAL, CEILING FS WATER FLOW ALARM SWITCH TS TAMPER SWITCH E ECS SPEAKER, FLUSH IN CEILING PIV POST INDICATOR VALVE SWITCH E ECS SPEAKER WITH VISUAL WARNING SIGNAL, CEILING T BEAM TRANSMITTER E ECS VISUAL WARNING SIGNAL, CEILING R BEAM RECEIVER FF FIRE FIGHTERS TELEPHONE E0.0 GENERAL NOTES AND SYMBOL LIST E0.1 ELECTRICAL SPECIFICATIONS E1.0 ELECTRICAL SITE PLAN E2.1 ENLARGED POWER AND DATA PLANS E3.1 ENLARGED FIRE ALARM PLANS E5.1 ELECTRICAL ONE-LINE DIAGRAM COPIES OF THE MANUAL SHALL BE AVAILABLE ON THE JOB SITE PRIOR TO THE START OF HANGING AND BRACING OF THE PIPE, DUCTWORK, AND ELECTRICAL DISTRIBUTION SYSTEMS. 3. ALL FLOOR AND WALL MOUNTED ELECTRICAL AND DATA OUTLETS TO BE REMOVED, CONDUIT AND WIRING TO BE REMOVED BACK TO ELECTRICAL PANEL. THE STRUCTURAL ENGINEER OF RECORD SHALL VERIFY THE ADEQUACY OF THE STRUCTURE TO SUPPORT THE HANGER AND BRACE LOADS. CIRCUIT HOME RUN FURNISH AND INSTALL ALL SYSTEMS, UNITS, EQUIPMENT, AND PARTS TO MEET OR EXCEED CURRENT APPLICABLE REQUIREMENTS FOR SEISMIC RESISTANCE SPECIFIED BY CODES, REGULATIONS, OR AGENCIES HAVING JURISDICTION. INCLUDE ALL SUPPORTS, ANCHORS, BRACES, AND OTHER RESTRAINING DEVICES REQUIRED. ALL SEISMIC RESTRAINTS SHALL MEET SEISMIC REQUIREMENTS SPECIFIED BY CODES, REGULATIONS, OR AGENCIES HAVING JURISDICTION AND ARE THE RESPONSIBILITY OF THE CONTRACTOR. CONDUIT TURNING DOWN 5. REMOVE ALL EXISTING DATA CABLING WIRING/ CONDUIT OCCURRING WITHIN THE TENANT PLENUM SPACE THAT IS NO LONGER IN USE, INCLUDING SERVICE TO FLOOR MOUNTED MONUMENTS. 6. REMOVE ALL TENANT-RELATED/ VOICE CABLING/ CONDUIT IN BUILDING'S CORE ELECTRICAL AND TELEPHONE CLOSETS BACK TO THE ELECTRICAL PANELS AND BACKBOARD, (INCLUDING PUNCH DOWN BLOCKS). PROTECT ALL THROUGH-FLOOR RISER CABLING, (BOTH VOICE AND DATA,) FROM DAMAGE, AND IF ANY QUESTIONS ARISE AS TO WHETHER TO DEMOLISH OR SAVE, CONTACT THE BUILDING MANAGEMENT FOR DIRECTION. 7. DISCONNECT AND REMOVE EXISTING POWER AND TELE/ DATA CABLES FROM EXISTING WORKSTATION FURNITURE FEED OUTLET BOX. EXTEND ASSOCIATED CONDUIT AND WIRING TO THE NEAREST JUNCTION BOX. PATCH AND PAINT WALL TO MATCH EXISTING WALL FINISH. 8. REMOVE EXISTING FLOOR OUTLETS AND INSTALL ABANDONMENT PLATES AND CLOSURE PLUGS WITH SAME FINISH AS EXISTING INSTALLATION. PROVIDE THREADED COVER WITH FIRE STOPPING. FIELD VERIFY EXACT OUTLET LOCATIONS. 9. DISCONNECT AND REMOVE EXISTING POWER AND TELE/DATA CABLES FROM EXISTING WORKSTATION FURNITURE FEED OUTLET BOX. EXTEND ASSOCIATED CONDUIT AND WIRING TO THE NEAREST JUNCTION BOX. PATCH AND PAINT WALL TO MATCH EXISTING WALL FINISH. 10. PROVIDE BLANK COVER PLATES ON JUNCTION BOXES WHICH ARE NOT REUSED. 11. PROVIDE CUTTING AND PATCHING AS REQUIRED, WHETHER OR NOT SPECIFICALLY INDICATED. VERIFY EXTENT OF NEW AND EXISTING PARTITIONS WITH ARCHITECTURAL DRAWINGS. 12. REMOVE ALL UNUSED CONDUITS AND WIRING, SWITCHES, RECEPTACLES, LIGHT FIXTURES, ETC., WHERE CEILING, CEILING TILES OR WALLS ARE BEING DEMOLISHED EXCEPT AS FOLLOWS: WHERE WALLS AND CEILINGS ARE TO REMAIN, MAINTAIN EXISTING CONDUIT, WIRING AND BOXES SERVING ALL ELECTRICAL EQUIPMENT, OUTLETS AND SWITCHES IN THE THOSE AREAS. REMOVE ALL POWER WIRING BACK TO ITS OVER CURRENT DEVICE AND MARK CIRCUIT BREAKERS AS "SPARE". INSTALL BLANK COVER ON ALL BOXES. REFER TO DRAWINGS FOR ADDITIONAL REQUIREMENT AND OTHER SPECIFIC EXPECTATIONS. 13. COORDINATE ALL DEMOLITION WORK WITH NEW REQUIREMENTS TO ASSURE THAT EXISTING EQUIPMENT, WIRING, ETC., THAT IS REQUIRED FOR A COMPLETE AND OPERABLE SYSTEM IS NOT REMOVED. DISTRIBUTED ANTENNA (CEILING) PIPING, DUCTWORK, AND ELECTRICAL DISTRIBUTION SYSTEMS SHALL BE BRACED TO RESIST THE FORCES PRESCRIBED IN ASCE 7 SECTION 13 AS DEFINED IN ASCE 7 SECTION 13.6.8 - 13.6.8 - 13.6.8.4, 13.6.7, AND 13.6.5.6, RESPECTIVELY. 2. RETAIN EXISTING EMERGENCY LIGHTING, PROPERLY BRACED FOR USE ON TEMPORARY BASIS UNTIL NEW LIGHTING IS PROVIDED ON EACH FLOOR. 4. ALL ELECTRICAL CORES TO BE FILLED WITH CONCRETE. SMOKE DETECTOR - IONIZATION TYPE (D = DUCT) PIPING, DUCTWORK, AND ELECTRICAL DISTRIBUTION SYSTEM BRACING NOTES POWER CONDUIT TURNING UP CONDUIT STUB-UP CONDUIT SLEEVE * EQUIPMENT ANCHORAGE AND SUPPORT INDICATED ON THESE DRAWINGS IS CONCEPTUAL IN NATURE. FOR PROJECT SPECIFIC EQUIPMENT, DUCTWORK, PIPING, ETC. ANCHORAGE AND SUPPORT, THE CONTRACTOR SHALL ENGAGE THE SERVICES OF A STRUCTURAL ENGINEER LICENSED IN CALIFORNIA TO PROVIDE COMPLETE DESIGN OF ALL SUPPORT AND BRACING SYSTEMS. THE DESIGN AND INSTILLATION SHALL COMPLY WITH THE REQUIREMENTS OF THE 2013 CALIFORNIA BUILDING CODE, CHAPTER 16 AND ASCE 7, CHAPTER 13 AND ALL CITY AMENDMENTS AND IR'S. ALL CONNECTIONS TO STRUCTURE SHALL BE MADE BY THE USE OF HARDWARE WITH BOLTS, WELDS OF OTHER POSITIVE ATTACHMENTS. FRICTION CONNECTIONS ARE NOT PERMITTED. GENERAL DESIGN CRITERIA SHALL BE AS SHOWN ON STRUCTURAL DRAWINGS. IN APPLYING EQUATIONS FROM SECTION 13 OF ASCE 7, THE MINIMUM FOLLOWING DESIGN COEFFICIENTS SHALL BE USED: RIGID: AIR SIDE Ap = 2.5 AND Rp = 2.5 WET SIDE Ap = 1.0 AND Rp = 2.5 FLEX: NEOPRENE Ap = 2.5 AND Rp = 6.0 SPRING/RESTRAINED Ap = 1.0 AND Rp = 2.5 DIAGONAL LINE THROUGH SYMBOL OR DENOTED 'AC' INDICATES MOUNT DEVICE ABOVE COUNTER. WHERE INDICATED AS 'MOUNT ABOVE COUNTER' MOUNT BOTTOM OF BOX 2-INCHES ABOVE TOP OF BACKSPLASH OR 6-INCHES ABOVE COUNTERTOP IF NO BACKSPLASH EXISTS. SIMPLEX RECEPTACLE DUPLEX RECEPTACLE DUPLEX RECEPTACLE, GFI TYPE DUPLEX RECEPTACLE, MOUNT ABOVE COUNTER DUPLEX RECEPTACLE, GFI TYPE, MOUNT ABOVE COUNTER CONDUIT CONCEALED IN FLOOR OR UNDERGROUND, OTHER (* = SEE ABBREVIATIONS) EXPOSED CONDUIT, POWER EXPOSED CONDUIT, OTHER (* = SEE ABBREVIATIONS) * * T FOURPLEX RECEPTACLE FOURPLEX RECEPTACLE, GFI TYPE FOURPLEX RECEPTACLE, MOUNT ABOVE COUNTER FOURPLEX RECEPTACLE, GFI TYPE, MOUNT ABOVE COUNTER TRANSFORMER XXX BRANCH CIRCUIT PANEL BOARD XXX XXX CURRENT TRANSFORMER ENCLOSURE M METER DUPLEX RECEPTACLE, HORIZONTALLY MOUNTED DUPLEX RECEPTACLE, HORIZ. MTD, GFI TYPE DUPLEX RECEPTACLE, HORIZ. MTD, ABOVE COUNTER DUPLEX RECEPTACLE, HORIZ. MTD, GFI TYPE, MOUNT ABOVE COUNTER GENERATOR GEN ATS AUTOMATIC TRANSFER SWITCH WEATHER RESISTANT GFI DUPLEX RECEPTACLE, ROOF MOUNT 18-INCHES ABOVE ADJACENT STRUCTURE WITH A WEATHERPROOF, IN-USE COVER R SYSTEM GROUND ELECTRODE T WEATHER RESISTANT GFI DUPLEX RECEPTACLE, MOUNT 18-INCHES AFF WITH A WEATHERPROOF, IN-USE COVER THERMOSTAT WP MUSHROOM GFI DUPLEX RECEPTACLE TO SERVE ELECTRIC WATER COOLER, MOUNT AT HEIGHT PER EWC EQUIPMENT MANUFACTURER'S INSTALLATION GUIDELINES DUPLEX RECEPTACLE TO SERVE TELEVISION, MOUNT AT SAME HEIGHT AND WITHIN 8-INCHES TV OF ADJACENT TV OUTLET MH ELECTRICAL MANHOLE Ip = 1.0 , Ip = 1.5 (FOR FIRE & LIFE SAFETY SYSTEMS), Sds = 1.0 , AND Z/H = 1.0 HH ELECTRICAL HAND HOLE M MOTOR CONNECTION, HORSEPOWER AS INDICATED ALL MECHANICAL EQUIPMENT IS REQUIRED TO BE INCLUDED IN THE SEISMIC RESISTANCE QUALITY ASSURANCE PLAN AS DESCRIBED UNDER QUALITY ASSURANCE ON SHEET S0.1. SF ST SM MANUAL SWITCH, WITH FUSE STARTER NEMA SIZE MOTOR RATED TOGGLE SWITCH DUPLEX RECEPTACLE, EMERGENCY MAGNETIC MOTOR STARTER FOURPLEX RECEPTACLE, EMERGENCY DISCONNECT SWITCH, WITH FUSE DUPLEX RECEPTACLE, LOWER SWITCH DISCONNECT SWITCH, WITHOUT FUSE DUPLEX RECEPTACLE, SWITCHED COMBINATION MOTOR STARTER RANGE RECEPTACLE RELAY PC PHOTOELECTRIC CELL A SPECIAL RECEPTACLE (MARK INDICATES OUTLET IN SCHEDULE) MULTIDEVICE FLOOR BOX WITH DUPLEX AND DATA OUTLETS, DIVIDED 2 GANG BOX WITH SINGLE GANG PLASTER RING SWITCH, PUSH BUTTON, SINGLE SWITCH, PUSH BUTTON, DOUBLE SWITCH, PUSH BUTTON, TRIPLE MULTI-RECEPTACLE STRIP, SPACING AS INDICATED LC LIGHTING CONTACTOR DIVIDED RACEWAY OS OCCUPANCY SENSOR FLUSH JUNCTION BOX, CEILING MOUNTED JUNCTION BOX ABOVE SUSPENDED CEILING WITH FLEX CONNECTION J FLUSH JUNCTION BOX, WALL MOUNTED J SURFACE JUNCTION BOX, CEILING MOUNTED J SURFACE JUNCTION BOX, WALL MOUNTED PULL BOX EQUIPMENT CONNECTION EQUIPMENT CONNECTION XXXX/3 ENCLOSED SWITCH; MOUNT 60-INCHES AFF TO TOP XX/X = AMP RATING / NO. OF POLES XXAF = FUSE SIZE; AF=AMP FUSE; NF=NO FUSE = ENCLOSURE NEMA RATING; BLANK=NEMA 1; WP=NEMA 3R XX M STAND-ALONE CURRENT TRANSFORMER CABINET METER SOCKET/METER WITH CONNECTION TO BMS SYSTEM AMP RATING / NO. OF POLES = AMP RATING / NO. OF POLES MAIN MAIN BREAKER COMBINATION MAGNETIC CONTROLLER; MOUNT 60-INCHES AFF TO TOP XX/X = AMP RATING / NO. OF POLES XXAF = FUSE SIZE; AF=AMP FUSE; NF=NO FUSE = STARTER NEMA SIZE XX CT CAB = XXX/X DISTRIBUTION BREAKER DISTRIBUTION FUSIBLE SWITCH SYSTEM GROUND ELECTRODE INDICATES CONTROLLED RECEPTACLE TO BE C CONNECTED TO OCCUPANCY SENSOR MANUAL SWITCH, WITH THERMAL OVERLOAD R PB = DUPLEX RECEPTACLE, FLUSH IN CEILING SWITCHBOARD CT J X DISTRIBUTION PANEL BOARD EQUIPMENT CABINET, AS NOTED MAIN FUSIBLE SWITCH ENCLOSED CONTROLLER (ACROSS-THE-LINE UNO) MOUNT 60-INCHES AFF TO TOP RECEPTACLES CONDUIT CONCEALED IN CEILING OR WALLS, POWER CONDUIT CONCEALED IN CEILING OR WALLS, OTHER (* = SEE ABBREVIATIONS) CONDUIT CONCEALED IN FLOOR OR UNDERGROUND, POWER SEE STRUCTURAL DRAWINGS FOR ALL SEISMIC DESIGN LOAD FACTORS. PER ASCE 7 SECTION 13.6.7 COMPONENTS INSTALLED IN-LINE WITH THE DUCT SYSTEM AND HAVE A OPERATING WEIGHT GREATER THAN 75 LBS SHALL BE SUPPORTED AND LATERALLY BRACED INDEPENDENT OF THE DUCT SYSTEM. (VAV BOXES AND OTHER DUCT MOUNTED COMPONENTS LESS THEN 75 LBS DO NOT REQUIRE LATERAL BRACING.) ONE-LINE DIAGRAM CONDUIT SEAL NF 3/31/2016 10:41:24 PM SAFETY : CEILING MOUNTED LIGHTING CONTROL DEVICES MAXIMUM MOUNTING HEIGHT OF 10-FEET AFF DAS 14. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR MAINTAINING THE INTEGRITY AND FUNCTIONALITY OF THE EXISTING LIGHTING, POWER, FIRE ALARM, IT/AV, SECURITY AND ANY OTHER SYSTEM FEEDING EXISTING SATELLITE CONTROL ROOM TO REMAIN ENERGIZED AND OPERATIONAL AT ALL TIME DURING DEMOLITION AND CONSTRUCTION WORK. C:\Revit\75-15270-01_MEP_2015_Cental_tfritson.rvt DIRECTORS HEADSET D LOW VOLTAGE LIGHTING CONTROLLER INTERFACE. WLC FOR THOSE ELEMENTS THAT DO NOT REQUIRE DETAILS ON THE APPROVED DRAWINGS, THE INSTALLATION SHALL BE SUBJECT TO THE APPROVAL OF THE MECHANICAL ENGINEER. GENERAL DEMOLITION NOTES FLUSH FLOOR BOX WITH MICROPHONE OUTLET LOW VOLTAGE WIRELESS TOUCH SCREEN SWITCHING INTERFACE. LIGHTING CONTROL DEVICES: PC M LOW VOLTAGE TOUCH SCREEN SWITCHING INTERFACE. WTS BOLLARD LIGHT FIXTURE LOW VOLTAGE RELAY MM LOW VOLTAGE SWITCH CONTROLLING (N) ZONES. PROVIDE EITHER 2,4, OR 6 BUTTON SWITCHES. POLE MOUNTED AREA LIGHTING FIXTURE IN GRADE LIGHT FIXTURE BUZZER M SWITCH, WALL-BOX VACANCY SENSOR S TECHNOLOGY OUTLET, CEILING (MULTI-MEDIA) VOLUME CONTROL, WALL V S C V T R TELEVISION TERMINAL CABINET INTERCOM CALLBACK STATION, WALL EQUIPMENT ANCHORAGE NOTE A. EQUIPMENT WEIGHING LESS THAN 400 POUNDS SUPPORTED DIRECTLY ON THE FLOOR OR ROOF. B. FURNITURE REQUIRED TO BE ATTACHED IN ACCORDANCE WITH ASCE 7, C. TEMPORARY OR MOVABLE EQUIPMENT WITH FLEXIBLE CONNECTION TO POWER OR UTILITIES. D. EQUIPMENT WEIGHING LESS THAN 20 POUNDS SUPPORTED BY VIBRATION ISOLATORS. E. EQUIPMENT WEIGHING LESS THAN 20 POUNDS SUSPENDED FROM A ROOF OR FLOOR OR HUNG FROM A WALL. TV IC SWITCH, TIMER CENTRAL INVERTER SB SMART-BOARD TECHNOLOGY OUTLET, WALL SPEAKER/HORN, WALL O2 CVX TELEVISION OUTLET, CEILING H SWITCH, WALL-BOX OCCUPANCY SENSOR, 2-POLE LIGHTING CONTROL RELAY PANEL TV SPEAKER, CEILING O RPX MM MULTI-MEDIA TECHNOLOGY OUTLET, WALL S SWITCH, WALL-BOX OCCUPANCY SENSOR POLE WITH POLE MOUNTED AREA LIGHTING FIXTURE THE ATTACHMENT OF THE FOLLOWING ITEMS SHALL BE DESIGNED TO RESIST THE FORCES PRESCRIBED ABOVE, BUT NEED NOT BE DETAILED ON THE PLANS, AND THE PROJECT INSPECTOR WILL VERIFY THAT THESE ITEMS (EQUIPMENT) HAVE BEEN ANCHORED: TELEVISION OUTLET, WALL SWITCH, DIMMER M WALL MOUNTED LIGHTING FIXTURE ALL MECHANICAL AND ELECTRICAL EQUIPMENT SHALL BE ANCHORED OR BRACED TO MEET THE HORIZONTAL AND VERTICAL FORCES PRESCRIBE IN THE 2013 CBC, SECTION 1615.10.15-13.6.7, 1615.16-13.6.8 - 13.6.8.4, 1615A.1.21-13.6.7, 1615A.1.22-13.6.8 - 13.6.8.4 AND 1615.10.14-13.6.5.6. TV TIME CLOCK SPEAKER, WALL S WALL MOUNTED AREA LIGHTING FIXTURE 1. SEE LIGHT FIXTURE SCHEDULE OR SYMBOLS LEGEND FOR MOUNTING HEIGHTS, UNLESS NOTED OTHERWISE. TECHNOLOGY OUTLET, WALL (VOICE, DATA, CATV) CLOCK - OUTLET S SWITCH, EMERGENCY SWITCH, MASTER EXIT SIGN, CEILING MOUNTED, DIRECTIONAL ARROW(S) AS INDICATED DIVISION 27 AND 28 WORK TELEPHONE BACKBOARD, SIZE AS SHOWN TELEPHONE CABINET (PBX) FLUSH FLOOR BOX WITH TWO (2) TECHNOLOGY OUTLETS (MULTI-MEDIA) S E S LIGHTING FIXTURE CLOCK - DOUBLE FACE DS C TC CHIME LIGHTING FIXTURE ON EMERGENCY SYSTEM S CLOCK - MASTER C CEILING FIXTURE, SURFACE, RECESSED OR PENDANT LIGHTING TRACK, TRACK MOUNTED LIGHT FIXTURE SEISMIC ANCHORAGE NOTES PAY TELEPHONE OUTLET M FLUSH FLOOR BOX WITH TECHNOLOGY OUTLET S SELF CONTAINED EMERGENCY LIGHTING UNIT MOUNT 94-INCHES AFF, UNO SPECIAL SYSTEMS NOTES P SWITCH, SINGLE POLE S SITE LIGHTING - POLE 5. CIRCUIT FIXTURES DENOTED WITH 'NL' AS UNSWITCHED NIGHT LIGHTS. POLE(S) PUBLIC ADDRESS PULL BOX PHASE POST INDICATOR VALVE PANEL POWER LIGHTING FIXTURE AREA LIGHTING DEVICES: TELEPHONE OUTLET FOR WALL-MOUNTED PHONE SUBSCRIPT, SWITCH TYPE - SEE BELOW S 8. DEVICES RECESSED IN MULLIONS: BACK BOXES TO BE RECESSED FOR FLUSH NSTALLATION OF DEVICE AND WALLPLATE. EXTEND CONCEALED CONDUIT IN MULLION UP TO WALL ABOVE AND STUB OUT ABOVE ACCESSIBLE CEILING. IN AREAS WITH NO CEILING, EXTEND CONDUIT TOWARDS CABLING SOURCE TO ABOVE NEAREST ACCESSIBLE CEILING. W SWITCH SYMBOL EXIT SIGN, WALL MOUNTED, DIRECTIONAL ARROW(S) AS INDICATED. MOUNT 94-INCHES AFF, UNO 4. PROVIDE BEAD OF SILICON SEALANT AROUND RECESSED BACK BOX PERIMETER AT ALL BUILDING MOUNTED EXTERIOR LIGHT FIXTURE LOCATIONS. P PA PB PH PIV PNL PWR x X S 4. FLOOR BOXES: OBTAIN OWNER APPROVAL OF ALL BOX LOCATIONS PRIOR TO ROUGH IN. PROVIDE DEVICE PLATES AT DEVICES AND BLANK PLATES AT ALL UNUSED COMPARTMENTS. 12. CONDUIT IN CMU WALLS SHALL BE RGC, AND ROUTING TO BE APPROVED BY STRUCTURAL ENGINEER AND ARCHITECT. INTERCOM ISOLATED GROUND INCH INTERIOR OWNER FURNISHED, CONTRACTOR INSTALLED OVERHEAD CKT DESIGNATION (PNL - CKT NO.) RELAY PANEL - RELAY NO. OR LOCAL SWITCH DESIGNATION 11. ALL ELECTRICAL EQUIPMENT TO COMPLY WITH REQUIREMENTS OUTLINED IN THE SEISMIC RESISTANCE QUALITY ASSURANCE PLAN ON SHEET S0.1. IC IG IN INT OFCI OH 3. PROVIDE BOX EXTENDER FOR FLUSH INSTALLATION OF DEVICES LOCATED IN ARCHITECTURAL CASEWORK THAT IS FLUSH WITH ADJACENT WALL (SUCH AS RECEPTACLES FOR GARBAGE DISPOSERS). FIXTURE TYPE CLOCK TELEPHONE OUTLET, WALL SUPERSCRIPT , SWITCH SHALL CONTROL FIXURE DENOTED WITH SAME LOWER CASE LETTER S 10. ALL BREAKERS FEEDING FIRE LIFE SAFETY LOADS (SUCH AS FACP, CFSD, ETC.) SHALL BE PROVIDED WITH PROPER LABELING PER [ NFPA 72 - SECTION 10.5 ] AS WELL AS LOCK-ON TYPE BREAKER. HANDHOLE HAND-OFF-AUTOMATIC HORSE POWER NEUTRAL NORMALLY CLOSED NORMAL OPEN NON-FUSED NOT IN CONTRACT NIGHT LIGHT NOT TO SCALE XXX XXX-X XXX-X 7. CEILING MOUNTED RECEPTACLES: AT SUSPENDED CEILINGS, ROUTE POWER TO RECEPTACLE VIA FLEXIBLE METALLIC CONDUIT WITH 6-FOOT SERVICE LOOP. FEED FMC FROM A J-BOX RIGIDLY SUPPORTED A MAXIMUM OF 24-INCHES ABOVE SUSPENDED CEILING OR AT BOTTOM OF STRUCTURE ABOVE, WHICHEVER IS LOWER. LOCATE J-BOX DIRECTLY ABOVE RECEPTACLE AND SUPPORT VIA STRUCTURE, OR VIA THREAD ROD AND UNISTRUT HUNG FROM STRUCTURE ABOVE IN HIGH STRUCTURE APPLICATIONS. 8. SWBDS, DIST BDS, PANELS, DISC SWITCHES, ATS, MAINTENANCE BYPASS DIST BDS, UPS, BATTERY CABINETS, ENCLOSED CIRCUIT BREAKERS, TRANSFORMERS, SHALL HAVE LAMICOID LABEL DENOTING POWER SOURCE. HH HOA HP N N.C. N.O. NF NIC NL NTS 2. ALL MOUNTING HEIGHTS ARE TO CENTERLINE OF BOXES UNLESS NOTES OTHERWISE. 6. COORDINATE LOCATION OF DEVICE BOXES FOR SWITCHES, RECEPTACLES, AND SYSTEMS DEVICES WITH TACKBOARDS. ADJUST BOX LOCATIONS TO AVOID TACKBOARDS. PROVIDE BOX EXTENDER FOR A FLUSH INSTALLATION WHERE DEVICES MUST BE MOUNTED AT TACKBOARD/TACKWALL. 6. ALL OVERCURRENT PROTECTION DISCONNECTING MEANS SHALL BE FULLY RATED. SERIES RATING IS NOT ALLOWED FOR THIS PROJECT. SWITCHES: MOUNT 42-INCHES AFF UNO LIGHTING FIXTURE TAG 5. COORDINATE LOCATION OF DEVICE BOXES FOR SWITCHES, RECEPTACLES, AND SYSTEMS DEVICES WITH MARKERBOARDS. ADJUST BOX LOCATIONS TO AVOID MARKERBOARDS. 5. PROVIDE #10AWG CONDUCTORS FOR ALL WARM AIR DRYER CIRCUITS. PROVIDE LOCKOUT DEVICE AT ALL BREAKERS SERVING WARM AIR DRYERS. EQUIPMENT GROUNDING CONDUCTOR GENERATOR GROUND FAULT CIRCUIT INTERRUPTER GROUND FAULT CIRCUIT INTERRUPTER EQUIPMENT GROUNDING CONDUCTOR MAXIMUM MINIMUM CIRCUIT AMPACITY MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MECHANICAL MANUFACTURER MANHOLE MINIMUM MAIN LUGS ONLY MAXIMUM OVERCURRENT PROTECTION MOTOR RATED TOGGLE SWITCH MAIN SWITCHBOARD MOUNTED MOUNTING MANUAL TRANSFER SWITCH 3. DEVICES AND LIGHT FIXTURES DENOTED 'ER' ARE EXISTING TO BE RELOCATED. NOTIFY A/E IF DEVICES OR FIXTURES ARE DAMAGED. 4. LOCATE SWITCHES FOR CONTROL OF FANS IN TWO-GANG BOX WITH LIGHT SWITCH WHERE APPLICABLE. G GEN GFI GFCI GND MAX MCA MCB MCC MECH MFR MH MIN MLO MOCP MRTS MSB MTD MTG MTS 2. EXISTING PANEL DIRECTORIES AT PANELS AFFECTED BY WORK: PROVIDE UPDATED TYPED PANEL DIRECTORY. CONSULT OWNER FOR INPUT ON LABELING OF ALL EXISTING CIRCUITS. 1. SEE SYMBOLS LEGEND THIS SHEET FOR MOUNTING HEIGHTS UNLESS NOTED OTHERWISE ON DRAWINGS. SWITCH CONDUIT CIRCUIT BREAKER CABLE TELEVISION CLOSED CIRCUIT TELEVISION CIRCUIT CEILING COPPER 2. PROVIDE DEDICATED 120-VOLT CIRCUITS TO ALL HVAC BAS CONTROL DEVICES AND PANELS. COORDINATE QUANTITY WITH DIVISION 23. UTILIZE NEAREST SPARE 120-VOLT, 20/1 BREAKER. LABEL TYPED PANEL DIRECTORY ACCORDING TO LOAD BEING SERVED. 1. MODIFICATIONS TO EXISTING POWER DISTRIBUTION EQUIPMENT: MATCH EXISTING MANUFACTURER, SWITCH TYPE, FUSE TYPE, BREAKER TYPE AND KAIC RATING FOR ALL INSTALLED DEVICES. COMMUNICATIONS FUSE SIZE C CB CATV CCTV CKT CLG CU 1. VERIFY ANY NEUTRAL WIRES REQUIRED ON 1Ø OR 3Ø MECHANICAL UNITS FURNISHED UNDER DIVISION 23. IF REQUIRED, PROVIDE NEUTRAL. LIGHTING Saugus Union School District - West Creek Academy (TYPICAL ALL SHEETS) U USB ONLY RECEPTACLE U RECEPTACLE WITH USB PORTS H HAND DRYER, INSTALL HAND DRYER SPECIFIED IN DIV. 11 FF FURNITURE FEED, FLUSH WITH FLOOR. , DLR Group inc., SELECT STATE project is IN, ALL RIGHTS RESERVED (TYPICAL ALL SHEETS) © (TYPICAL ALL POWER SHEETS) Interim Housing AMPERE ABOVE COUNTER AMPERE INTERRUPTING CAPACITY AMP FRAME (CIRCUIT BREAKER) ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AUTHORITY HAVING JURISDICTION ALUMINUM AMERICAN WIRE GAUGE WIRELESS ACCESS POINT AMP TRIP (CIRCUIT BREAKER OR FUSE) AUTOMATIC TRANSFER SWITCH AUDIO-VIDEO Revisions A AC AIC AF AFF AFG AHJ AL AWG AP AT ATS AV THIS IS A DEFAULT - Select State - THIS IS A DEFAULT DEVICE BOXES AND RACEWAYS 75-15270-01 03/31/2016 REMODEL NOTES CONSTRUCTION DOCUMENTS GENERAL POWER NOTES GENERAL NOTES AND SYMBOL LIST PHASE E0.0 ø BREAKER SIZE ABBREVIATIONS 1.09 MAINTENANCE MANUALS AND AS-BUILT DRAWINGS A. PROVIDE FOUR (4) COPIES OF OPERATING AND MAINTENANCE MANUAL FOR OWNER'S USE FOR EACH PIECE OF EQUIPMENT. EACH ITEM SHALL BE CROSS-REFERENCED AND NUMBERED WITH AS-BUILT DRAWING DESCRIPTIONS. B. AS-BUILT DRAWINGS: DELIVER TO OWNER, ONE ELECTRONIC ACAD SET OF ALL DRAWINGS AND PANEL SCHEDULES IN HARDCOPY AND ONE ON CD. 1.10 SEISMIC SUPPORT A. CONTRACTOR SHALL SUPPORT AND BRACE ALL NEW ELECTRICAL SYSTEMS IN ACCORDANCE WITH SEISMIC CODE REQUIREMENTS. 2.00 PRODUCTS 2.01 GENERAL A. NAMEPLATES: 1.FASTENED WITH EPOXY CEMENT, ENGRAVED WHITE LAMICOID SHEET WITH 3/4 IN. BLACK LETTERING. 2.INSCRIPTION: SUBJECT TO REVIEW, INDICATING EQUIPMENT AND VOLTAGE. 3.PROVIDE FOR: a. DISCONNECT SWITCHES. b. CIRCUIT BREAKERS. c. PANELS. d. CABINETS. B. INSERTS AND SUPPORTS: 1.SINGLE ROD: SIMILAR TO GRINNELL FIG. 281. 2.MULTI-ROD: SIMILAR TO FEE MASON SERIES 9000 WITH END CAPS AND CLOSURE STRIPS. 3.CLIP FROM NAILS FLUSH WITH INSERTS. % OF RATING. 4.MAXIMUM LOADING 75 5.SUPPORTS FROM BUILDING CONSTRUCTION: INSERTS, BEAM CLAMPS, STEEL FISHPLATES (IN CONCRETE FILL ONLY) OR CANTILEVER BRACKETS. 6.GROUPED LINES AND SERVICES: TRAPEZE HANGERS OF BOLTED ANGLES OR CHANNELS. 7.WHERE BUILDING CONSTRUCTION IS INADEQUATE: PROVIDE ADDITIONAL FRAMING. 2.02 MATERIALS A. RACEWAYS: 1.ELECTROMETALLIC TUBING (EMT): THIN WALL PIPE, GALVANIZED, THREADLESS. 2.FLEXIBLE STEEL CONDUIT: CONTINUOUS SINGLE STRIP, GALVANIZED. 3.WIREWAYS: a. SIZE: AS NOTED. MINIMUM NO. 16 GAUGE STEEL WITH GROUND CONTINUITY. b. FINISH: BAKED ENAMEL. c. COVER: SCREW ON. B. FITTINGS AND ACCESSORIES: 1.RACEWAY FITTINGS: a. RIGID STEEL: NONSPLIT, THREADED, STEEL OR MALLEABLE IRON. ZINC DIE CAST NOT PERMITTED b. ELECTROMETALLIC TUBING: COMPRESSION OR DOUBLE SET SCREW TYPE. GALVANIZED RIGID STEEL ELBOWS., 2 IN. OR LARGER. C. c. FLEXIBLE METALLIC CONDUIT: ANGLE WEDGE TYPE WITH INSULATED THROAT. d. BUSHINGS: METALLIC INSULATED TYPE. BOXES: 1.OUTLET BOXES: EXCEPT AS OTHERWISE REQUIRED BY CONSTRUCTION, DEVICES OR WIRING. a. STAMPED OR WELDED STEEL, 4 IN. SQUARE OR OCTAGON FOR: a.a. LIGHTING FIXTURES: 1½ IN. DEEP ABOVE CEILING, 2-1/8 IN. DEEP IN WALL. a.b. IN WALL FOR RECEPTACLES AND SWITCHES: 1½ IN. DEEP. a.c. IN WALL FOR TELEPHONE AND DATA: 2-1/8 IN. DEEP. a.d. WITH RAISED COVERS AND FIXTURE STUDS WHERE REQUIRED. a.e. THROUGH-THE-WALL TYPE, NOT PERMITTED. a.f. WITHOUT FIXTURE OR DEVICE: BLANK COVER. a.g. OFFSET BACK-TO-BACK OUTLETS: MINIMUM 6 IN. SEPARATION. b. GALVANIZED CAST IRON OR ALUMINUM WITH THREADED HUBS: 4 INCH ROUND, 2 INCH DEEP ON CEILING, AND 4 INCH SQUARE, 2 INCH DEEP ON WALL. c. BOXES FOR OUTDOORS AND DAMP LOCATIONS: WEATHERPROOF, CAST METAL. d. BOXES WITHOUT FIXTURE OR DEVICE: PROVIDE WITH BLANK COVER 2.JUNCTION AND PULL BOXES: a. GALVANIZED SHEET STEEL. b. COVERS: SCREW-ON, EXCEPT AS NOTED. c. WITH INSULATED SUPPORTS FOR CABLES. d. LOCATION: AS NOTED OR REQUIRED AND ACCESSIBLE. e. PROVIDE BARRIERS BETWEEN: e.a. 480Y/277 VOLT WIRING ENERGIZED FROM SEPARATE SERVICES. e.b. 208Y/120 VOLT AND 480Y/277 VOLT WIRING. e.c. EMERGENCY AND NORMAL WIRING. f. PROVIDE BARRIERS IN EXISTING BOXES BETWEEN: f.a. 208Y/120 VOLT 3.FLOOR BOXES: GALVANIZED CAST IRON WITH BRASS COVERS AND FLANGES, SUITABLE FOR CONDUIT AND DEVICES INDICATED. HARVEY DUALAVEL SERIES OR EQUAL. F. CONSTRUCTION DOCUMENTS I. 3.00 EXECUTION 3.01 INSTALLATION OF THE WORK A. THE CONTRACT DRAWINGS INDICATE THE GENERAL ARRANGEMENTS FOR THE ELECTRICAL SYSTEMS. 1.DRAWINGS ARE DIAGRAMMATIC AND DO NOT INDICATE NECESSARY OFFSETS, OBSTRUCTIONS OR STRUCTURAL CONDITIONS. 2.ABOVE ITEMS TO BE PERFORMED AT NO ADDITIONAL COST TO THE OWNER. 3.PROCEED AS RAPIDLY AS THE BUILDING CONSTRUCTION WILL PERMIT. 4.THOROUGHLY CLEAN ITEMS BEFORE INSTALLATION. CAP OPENINGS TO EXCLUDE DIRT UNTIL FINAL CONNECTIONS HAVE BEEN MADE. 5.CUT MATERIALS ACCURATELY, WORK INTO PLACE WITHOUT SPRINGING OR FORCING, PROPERLY CLEAR WINDOWS, DOORS AND OTHER OPENINGS. EXCESSIVE CUTTING OR OTHER WEAKENING OF THE BUILDING STRUCTURE WILL NOT BE PERMITTED. 6.MANUFACTURER'S DRAWINGS AND INSTRUCTIONS SHALL BE FOLLOWED IN ALL CASES WHERE THE MAKERS OF DEVICES AND EQUIPMENT FURNISH DIRECTIONS OR DETAILS NOT SHOWN ON THE DRAWINGS OR DESCRIBED IN THE SPECIFICATIONS. 7.DRAWINGS ARE NOT INTENDED TO BE SCALED, BUT SHALL BE FOLLOWED WITH SUFFICIENT ACCURACY TO COORDINATE WITH OTHER WORK. 8.SEISMIC DESIGN: THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ANCHORS, SUPPORTS AND CONNECTIONS OF ELECTRICAL WORK TO THE BUILDING STRUCTURE TO PREVENT DAMAGE AS A RESULT OF AN EARTHQUAKE, INCLUDING MANUFACTURED EQUIPMENT, THE CONNECTION AND INTEGRITY OF SHOP FABRICATED AND FIELD FABRICATED MATERIALS AND EQUIPMENT. ALL SUPPORTS, EQUIPMENT AND CONNECTIONS THERETO SHALL BE DESIGNED TO CONFORM TO REQUIREMENTS OF THE BUILDING CODE, OR OTHER GOVERNING CODES. 9.ALL WORK SHALL BE PROPERLY SUPPORTED FROM BUILDING STRUCTURE AND/OR FRAMING IN AN APPROVED MANNER, INDEPENDENT OF THE CEILING SUPPORT SYSTEM. WHERE OVERHEAD CONSTRUCTION DOES NOT PERMIT DIRECT FASTENING OF SUPPORTS, FURNISH ADDITIONAL FRAMING. 10. ALL EQUIPMENT SHALL BE SECURELY FASTENED TO BUILDING CONSTRUCTION WITH APPROVED SUPPORTS. 11. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF LIGHTING FIXTURES, SWITCHES, RECEPTACLES, TELEPHONE AND DATA OUTLETS (IF DEPICTED). IF ITEMS ARE NOT DEPICTED SPECIFICALLY ON ARCHITECT'S DRAWINGS, OBTAIN ARCHITECT'S APPROVAL FOR LOCATIONS PRIOR TO INSTALLATION. 12. COORDINATE THE WORK OF THIS SECTION WITH THE WORK OF OTHER SECTIONS IN AMPLE TIME FOR PROPER INSTALLATION AND CONNECTION. 13. CAREFULLY CHECK SPACE REQUIREMENTS, INCLUDING SERVICING SPACE REQUIREMENTS, WITH OTHER SECTIONS TO ENSURE THAT ALL EQUIPMENT AND MATERIALS CAN BE INSTALLED IN THE SPACES ALLOTTED THERETO. 14. PREPARE DRAWINGS, ATTEND MEETINGS, OBTAIN ALL APPROVALS REQUIRED BY ALL AUTHORITIES HAVING JURISDICTION, CONDUCT REQUIRED TESTS AND OBTAIN REQUIRED PERMITS. B. FIRE PROOFING: 1.FIRE SEALED ALL PENETRATION THRU RATED WALLS, FLOORS, AND CEILING WITH APPROVED METHOD BY LOCAL JURISDICTION. 2.SEAL PENETRATION IN ACCORDANCE WITH SECTION 07842. 3.SEAL PENETRATION THROUGH EXTERIOR WALLS AND ROOFS IN ACCORDANCE WITH SECTION 07920. C. RACEWAYS: 1.RUN CONCEALED, EXCEPT AS NOTED. 2.SUPPORTS: a. CEILING TRAPEZE, STRAP HANGERS OR WALL BRACKETS. b. U-BOLTS: AT EACH FLOOR LEVEL OF RISER RACEWAYS AND CONNECTED TO ACCEPTABLE SUPPORTS. c. RISER CLAMPS: AT EACH FLOOR LEVEL OR RISER RACEWAYS AND RESTING ON SLAB. d. SECURE RACEWAYS TO SUPPORTS WITH PIPE STRAPS OR U-BOLTS. e. SPACING: e.a. MINIMUM 10 FT. ON CENTERS FOR METALLIC RACEWA Saugus Union School District - West Creek Academy 1.08 PRODUCT DELIVERY, STORAGE AND HANDLING A. CHECK DIMENSIONS OF ACCESS ROUTE THROUGH THE SITE FROM DELIVERY POINT TO FINAL LOCATION. WHERE NECESSARY, SHIP IN CRATED SECTIONS OF SIZE TO PERMIT PASSING THROUGH AVAILABLE SPACE. DISMANTLE AND/OR REASSEMBLE, REPROVISION AND RETEST EQUIPMENT TOO LARGE TO PASS THROUGH AVAILABLE ACCESS ROUTE TO FINAL LOCATION IN ONE PIECE. SHIP EQUIPMENT IN ORIGINAL PACKAGES, TO PREVENT DAMAGING OR ENTRANCE OF FOREIGN MATTER. HANDLE AND SHIP IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. PROVIDE AND MAINTAIN PROTECTIVE COVERINGS DURING CONSTRUCTION. REPLACE AT NO EXPENSE TO OWNER, EQUIPMENT OR MATERIAL DAMAGED DURING STORAGE OR HANDLING, AS DIRECTED BY ARCHITECT. DEVICES: 1.LOCAL WALL SWITCHES: a. HEAVY DUTY, ROCKER QUIET TYPE. b. 20 AMP, 120/277 VOLT, AC. c. EQUAL TO LEVITON DECORA PLUS SERIES NOS. INDICATED. c.a. SINGLE POLE, NO. 5621-2, 1221-2. c.b. 3-WAY, NO. 5623-2, 1223-2. c.c. COORDINATE WITH ARCHITECT FOR FINISH COLOR. 2.DIMMER SWITCHES: SLIDER TYPE, SIZES AS INDICATED. EQUAL TO LUTRON LUMEA 2 SERIES WHITE AS INDICATED. a. INCANDESCENT TYPE, NT SERIES. 120V. b. LOW VOLTAGE TYPE, NTLV AND NTELV SERIES. 120V. c. FLUORESCENT TYPE, NTF SERIES, 120 VOLT AND 277 VOLT. d. COORDINATE WITH ARCHITECT FOR FINISH COLOR. 3.INSERTION RECEPTACLES: a. GROUNDED, EXCEPT AS NOTED. MEETING NEMA STANDARDS, PUBLICATION WD-1-1971. b. EQUAL TO LEVITON DECORA PLUS SERIES NOS. INDICATED. c. DUPLEX CONVENIENCE. c.a. FOR MULTI-OUTLET CIRCUITS, 125 VOLTS, 2 POLE, 3 WIRE, GROUNDED, 15 AMP, EQUAL TO NO. 16252. c.b. FOR SEPARATE CIRCUITS, 125 VOLTS, 2 POLE, 3 WIRE, GROUNDED, 20 AMP, EQUAL TO NO. 16352. c.c. GFIC TYPE, EQUAL TO 7599. c.d. COORDINATE WITH ARCHITECT FOR FINISH COLOR. d. SINGLE, EXCEPT AS NOTED. d.a. 125 VOLT, 2 POLE, 3 WIRE, GROUNDED. 20 AMP, EQUAL TO NO. 16351 e. SPECIAL USE: NON-INTERCHANGEABLE TYPES AND RATINGS. 4.FIRE RATED POKE-THROUGHS: a. TYPES, SEE DRAWINGS: 5.DEVICE PLATES: a. SEE ARCHITECT FOR TYPE AND FINISH. DEFAULT: SCREWLESS FACEPLATE IN WHITE. LOW VOLTAGE DISTRIBUTION EQUIPMENT: 1.DISCONNECT SWITCHES: a. FUSED OR NONFUSED AS NOTED. b. VOLTAGE AS REQUIRED. c. HEAVY DUTY, EXCEPT AS NOTED. d. HORSEPOWER RATED FOR MOTOR LOADS. e. TOGGLE TYPE: e.a. NON-FUSED, LOAD BREAKS. e.b. MAXIMUM RATINGS: e.b.a. 20 AMP AT 600 VOLTS. e.b.b. 30 AMP AT 250 VOLTS. e.c. 2 POLE: EQUAL TO ARROW-HART, NO. 6808F. e.d. 3 POLE: EQUAL TO ARROW-HART, NO. 7810F. f. KNIFE-BLADE TYPE: f.a. LOAD BREAK, QUICK-MAKE-QUICK-BREAK, UL CLASS R UP TO 600 VOLT. f.b. MAXIMUM RATING EXCEPT AS NOTED: 800 AMP. f.c. ARC QUENCHERS. f.d. INDIVIDUALLY MOUNTED: EQUAL TO GENERAL ELECTRIC "TH" OR EQUAL. f.e. PANELBOARD OR SWITCHBOARD MOUNTED: EQUAL TO GENERAL ELECTRIC "QMR" OR EQUAL. f.f. ENCLOSURES: DEAD FRONT, NEMA TYPE 1, EXCEPT AS NOTED. 2.FUSES: a. MATCH EXISTING. b. FOR MOTOR AND TRANSFORMER LOADS: b.a. CURRENT LIMITING, DUAL ELEMENT, TIME DELAY TYPE, MAXIMUM RATING: 600 AMP AT REQUIRED VOLTAGE. b.b. 200,000-AMP IC: EQUAL TO BUSSMANN FUSETRON FRN OR FRS OR LO-PEAK LPN OR LPS (UL CLASS R). c. FOR OTHER LOADS: c.a. CURRENT LIMITING, FAST ACTING TYPE. c.b. 200,000-AMP IC: EQUAL TO BUSSMANN LIMITRON KTN, KTS, OR KTU (UL CLASS R, UP TO 600 AMP; CLASS L, OVER 600 AMP). d. ALL FUSES: SAME MANUFACTURER. e. PROVIDE 1 SPARE MATCHING FUSE FOR EACH SET OF 3. 3.CIRCUIT BREAKERS: a. MOLDED CASE: a.a. THERMAL-MAGNETIC, QUICK-MAKE-QUICK-BREAK. a.b. MANUALLY OPERATED WITH INSULATED TRIP-FREE HANDLE. a.c. MULTI-POLE TYPES: WITH INTERNAL TRIP BAR. a.d. TERMINALS: UL LISTED FOR 75 DEGREE C AND SUITABLE FOR COPPER OR ALUMINUM CABLE. a.e. ENCLOSURES: DEAD FRONT, NEMA TYPE 1, EXCEPT AS NOTED. a.f. FRAMES, IC AND INTERCHANGEABLE TRIPS: a.f.a. 120/240 VOLTS, 100-AMP FRAMES. a.f.a.a. INTERRUPTING CAPACITY: PER DRAWINGS. a.f.a.b. 1, 2 AND 3 POLES. a.f.b. 240 VOLTS, 225 AMPERE FRAME: a.f.b.a. INTERRUPTING CAPACITY: PER DRAWINGS. a.f.b.b. 3 POLES. 4.DISTRIBUTION PANELS: a. MATCH EXISTING MANUFACTURER WHERE MANUFACTURER IS KNOWN AND IT IS POSSIBLE AND APPLICABLE, OR REPLACE WITH EATON CUTLER HAMMER SQUARE D. b. COPPER BUSSING c. HINGED ACCESS AND HINGED COVER: DOOR-IN-DOOR CONSTRUCTION. , DLR Group inc., SELECT STATE project is IN, ALL RIGHTS RESERVED E. H. LIGHTING FIXTURES: 1.PROVIDE FIXTURES, COMPONENTS AND LAMPS. 2.TYPE OF FIXTURES INDICATED BY LETTERS. 3.INCANDESCENT: 120 VOLT, EXCEPT AS NOTED. 4.FLUORESCENT: a. 277 VOLT, EXCEPT AS NOTED. b. SHALL BE CERTIFIED BY THE MANUFACTURER TO COMPLY WITH TITLE 24. 5.FIXTURE CATALOG NUMBERS USED TO ILLUSTRATE EQUIPMENT TYPE DO NOT NECESSARILY DENOTE REQUIRED MOUNTING EQUIPMENT OR ACCESSORIES. PROVIDE ACCESSORIES TO SUIT. 6.ELECTRONIC BALLASTS: a. BALLASTS SHALL BE COMPLETELY OF SOLID STATE DESIGN. b. BALLAST FACTOR OF 0.90 OR HIGHER. c. LAMP CURRENT CREST FACTOR LESS THAN 1.7. d. OPERATION SHALL BE AT A FREQUENCY GREATER THAN 20,000 HZ. e. POWER FACTOR SHALL BE 0.90 OR HIGHER. f. TOTAL HARMONIC DISTORTION SHALL BE 10 PERCENT OR LESS. g. LIGHT OUTPUT SHALL REMAIN CONSTANT FOR LINE VOLTAGE VARIATIONS OF PLUS OR MINUS 10 PERCENT. h. SOUND RATING OF "A". i. SPECIFIC DESIGN FOR 32-WATT T8 LAMPS. j. PROVIDE FILAMENT HEATING DURING STARTING TO AVOID ANY REDUCTION IN RATED LAMP LIFE. k. LISTED AS CLASS P. l. MEET ANSI SPECIFICATIONS AND FCC REQUIREMENTS FOR TRANSIENT PROTECTION AND EMI/RFI LIMITATION. m. A WARRANTY MUST BE IN FORCE COVERING REPLACEMENT OF BALLASTS, WHICH FAIL WITHIN FIVE (5) YEARS OF DATE OF INSTALLATION. n. ELECTRONIC BALLAST SHALL BE MANUFACTURED BY MAGNETEK, ADVANCE, MOTOROLA, OR LUTRON COMPANY. 7.CONTRACTOR'S BASE BID IS TO INCLUDE FIXTURES ON SCHEDULE (SEE DRAWINGS). OCCUPANCY SENSORS 1.120 VOLT OR 277 VOLT AS REQUIRED. 2.20 AMP CONTACT RATING. 3.SOURCE: ULTRASONIC OR INFRARED. 4.CEILING OR WALL MOUNTED AS REQUIRED. 5.CONTROL TRANSFORMER AND SWITCHING CONTROL: CLASS 2 WITH APPROVED PLENUM WIRING. 6.PROVIDE CONTROL SWITCHPACKS AS REQUIRED. 7.FIELD ADJUSTMENTS: a. SENSITIVITY. b. OFF DELAY (15 SEC. TO 30 MIN.). 8.COVERAGE PATTERNS, APPLICATION AND SENSOR LOCATIONS SHALL BE COORDINATED WITH MANUFACTURERS REPRESENTATIVE. 9.AS SCHEDULED ON DRAWINGS. 10. MANUFACTURER: WATT STOPPER TELEPHONE/DATA CONDUIT SYSTEM: 1.COMPLETE SYSTEM OF: a. EMPTY CONDUIT. b. PULL BOXES. c. OUTLETS. d. SLEEVES. e. FISHWIRES. f. TERMINAL BOARDS. g. TERMINAL STRIP CABINETS. 2.OUTLETS: a. WALL: 4 IN. SQUARE WITH BUSHED COVER PLATE. b. FLOOR: POKE-THROUGH FITTINGS. 3.TERMINAL BOARDS: FIREPROOF PLYWOOD, SIZES AS INDICATED. 4.CONDUIT: 3/4 IN. MINIMUM. Interim Housing 1.07 JOB CONDITIONS A. CONNECTIONS TO EXISTING WORK: 1.INSTALL NEW WORK AND CONNECT TO EXISTING WORK WITH MINIMUM INTERFERENCE TO EXISTING FACILITIES. 2.TEMPORARY SHUTDOWNS OF EXISTING SERVICES: a. AT NO ADDITIONAL CHARGES. b. AT TIMES NOT TO INTERFERE WITH NORMAL OPERATION OF EXISTING FACILITIES. c. ONLY WITH WRITTEN CONSENT OF OWNER. 3.ALARM AND EMERGENCY SYSTEMS: NOT TO BE INTERRUPTED. 4.MAINTAIN CONTINUOUS OPERATION OF EXISTING FACILITIES AS REQUIRED WITH NECESSARY TEMPORARY CONNECTIONS BETWEEN NEW AND EXISTING WORK. 5.CONNECT NEW WORK TO EXISTING WORK IN NEAT AND ACCEPTABLE MANNER. RESTORE EXISTING DISTURBED WORK TO ORIGINAL CONDITION INCLUDING MAINTENANCE OF WIRING CONTINUITY AS REQUIRED. B. REMOVAL AND RELOCATION OF EXISTING WORK: 1.DISCONNECT, REMOVE OR RELOCATE ELECTRICAL MATERIAL, EQUIPMENT AND OTHER WORK NOTED AND REQUIRED BY REMOVAL OR CHANGES IN EXISTING CONSTRUCTION. 2.PROVIDE NEW MATERIAL AND EQUIPMENT REQUIRED FOR RELOCATED EQUIPMENT. 3.DISCONNECT LOAD AND LINE END OF CONDUCTORS FEEDING EXISTING EQUIPMENT. 4.REMOVE CONDUCTORS FROM EXISTING RACEWAYS TO BE REWIRED. 5.TAPE BOTH ENDS OF ABANDONED CONDUCTORS AND CAP OUTLETS AND ABANDONED RACEWAYS. 6.CUT AND CAP ABANDONED FLOOR RACEWAYS FLUSH WITH CONCRETE FLOOR OR BEHIND WALLS AND CEILINGS. 7.DISPOSE OF REMOVED RACEWAYS AND WIRE. 8.DISPOSE OF REMOVED ELECTRICAL EQUIPMENT AS DIRECTED. 9.IF ASBESTOS INSULATION IS FOUND WHEN WORKING IN EXISTING AREAS, IMMEDIATELY STOP WORK AND NOTIFY ARCHITECT. DO NOT RESTART WORK UNTIL ADVISED IN WRITING BY ARCHITECT THAT IT IS SAFE TO DO SO FOLLOWING ABATEMENT, ENCAPSULATIONS, ETC. G. © 3/31/2016 10:41:24 PM C:\Revit\75-15270-01_MEP_2015_Cental_tfritson.rvt 1.05 REFERENCE STANDARDS A. PUBLISHED CODES, SPECIFICATIONS, STANDARDS, TESTS OR RECOMMENDED METHODS OF TRADE, INDUSTRY OR GOVERNMENTAL ORGANIZATIONS, OR LOCAL UTILITIES APPLY TO WORK IN THIS DIVISION WHERE CITY BELOW: 1.ANSI - AMERICAN NATIONAL STANDARDS INSTITUTE. 2.ASTM - AMERICAN SOCIETY OF TESTING AND MATERIALS. 3.CBM - CERTIFIED BALLAST MANUFACTURERS. 4.ETL - ELECTRICAL TESTING LABORATORIES. 5.FCC - FEDERAL COMMUNICATIONS COMMISSION. 6.FM - FACTORY MUTUAL. 7.ICEA - INSULATED CABLE ENGINEERS ASSOCIATION. 8.IEEE - INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS. 9.IES - ILLUMINATING ENGINEERING SOCIETY. 10. NEC - NATIONAL ELECTRICAL CODE. 11. NEMA - NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION. 12. NFPA - NATIONAL FIRE PROTECTION ASSOCIATION. 13. OSHA - OCCUPATIONAL SAFETY AND HEALTH ACT. 14. UBC - UNIFORM BUILDING CODE. 15. UL - UNDERWRITERS' LABORATORIES, INC. 16. LOCAL UTILITY AUTHORITIES. 17. ADA - AMERICANS WITH DISABILITIES ACT. 18. STATE OF CALIFORNIA CODES. 19. CITY OF LOS ANGELES CODES AND THEIR BUILDING DEPARTMENT. 1.06 PERMITS AND INSPECTIONS A. THE CONTRACTOR SHALL SECURE ALL APPROVALS AND PAY ALL FEES FOR ALL WORK INSTALLED. CERTIFICATE SHALL BE DELIVERED TO OWNER BEFORE FINAL PAYMENT WILL BE MADE. WIRE AND CABLE: 1.CONDUCTORS: SHALL BE BASED ON 75°C TEMPERATURE RAITING a. ASTM STANDARD SOLID NO. 10 AND SMALLER, STRANDED NO. 8 AND LARGER. a.a. TYPE: COPPER. a.b. SIZES: a.b.a. GENERAL USE: a.b.a.a. NO. 12 MINIMUM. a.b.a.b. AT 120 VOLTS AND OVER 100 FT. CIRCUIT LENGTH: NO. 10 MINIMUM. a.b.a.c. AT 277 VOLTS AND OVER 200 FT. CIRCUIT LENGTH: NO. 10 MINIMUM. a.b.b. CONTROL AND ALARM, EXCEPT AS NOTED: a.b.b.a. NO. 14 MINIMUM. a.b.b.b. AT 120 VOLTS AND OVER 200 FT. CIRCUIT LENGTH: NO. 12 MINIMUM. a.b.c. OTHER VOLTAGES AND PHASES: AS REQUIRED TO MAINTAIN VOLTAGE DROP. a.b.d. INCREASE RACEWAY SIZES FOR LARGER WIRE AS REQUIRED. 2.INSULATION: a. THWN/THHN: FEEDERS AND BRANCH CIRCUITS EXCEPT AS NOTED. b. ARMORED CABLE (AC) AND METAL CLAD CABLE (MC): NOT ALLOWED c. COLOR CODING: CONDUCTORS SHALL BE COLOR CODED TO DIFFERENTIATE THE PHASES, THE SAME COLOR CODE BEING ASSIGNED TO THE SAME PHASE THROUGHOUT THE PROJECT. 3.ACCESSORIES: a. TAGS: a.a. FLAMEPROOF LINEN OR FIBER IN ACCESSIBLE LOCATIONS. a.b. FEEDERS: INDICATE FEEDER NUMBER, SIZE, PHASE AND POINTS OF ORIGIN AND TERMINATIONS. a.c. CONTROL AND ALARM WIRING: INDICATE TYPE (CONTROL OR ALARM), SIZE OF WIRE, AND POINTS OR ORIGIN AND TERMINATIONS. b. TERMINATIONS, SPLICES AND TAPS UNDER 600 VOLTS: b.a. COPPER CONDUCTORS NO. 10 AND SMALLER: WITH COMPRESSION-TYPE OF TWIST-ON SPRING-LOADED CONNECTORS AND CLEAR NYLON-INSULATED COVERING. b.b. COPPER CONDUCTORS NO. 8 AND LARGER: MECHANICAL BOLTED PRESSURE OR HYDRAULIC COMPRESSION TYPE USING MANUFACTURER'S RECOMMENDED TOOLING. b.c. CABLE LUGS AND CONNECTORS: COMPRESSION TYPE OF SAME METAL AS CONDUCTOR. PROVIDE TO MATCH CABLE, WITH MARKING INDICATING SIZE AND TYPE. b.d. COPPER LUG CONNECTIONS TO BUS BARS: USE ANTI SEIZE COMPOUND ON TANG. Revisions 1.04 QUALITY ASSURANCE A. QUALITY AND GAUGES OF MATERIALS: 1.QUALITY OF MATERIALS: a. NEW, BEST OF THEIR RESPECTIVE KINDS, FREE FROM DEFECTS AND LISTED BY UNDERWRITERS' LABORATORIES, INC., OR BEARING THEIR LABEL. b. MATERIALS AND EQUIPMENT OF SIMILAR APPLICATION: SAME MANUFACTURE, EXCEPT AS NOTED. c. CONFORM TO NEMA, ANSI AND IEEE STANDARDS. B. CURRENT CHARACTERISTICS: 1.DISTRIBUTION: a. 480Y/277 VOLTS, 60 HERTZ WITH GROUNDED NEUTRAL. b. 208Y/120 VOLTS, 60 HERTZ WITH GROUNDED NEUTRAL. C. HEIGHTS OF OUTLETS: 1.FROM FINISHED FLOOR TO CENTERLINE OF OUTLETS FOR: a. RECEPTACLES AND TELEPHONES: a.a. GENERALLY: 1 FT. - 6 IN. a.b. OVER WORK BENCHES: 3 FT. - 6 IN. b. WALL SWITCHES: 3 FT. - 6 IN. c. MOTOR CONTROLLERS: 5 FT. - 0 IN. 2.EXCEPTIONS: a. AT JUNCTION OF DIFFERENT WALL FINISH MATERIALS b. ON MOLDING OR BREAK IN WALL SURFACE. c. IN VIOLATION OF CODE. d. AS NOTED OR DIRECTED. D. THIS IS A DEFAULT - Select State - THIS IS A DEFAULT 1.03 SUBMITTALS A. PROVIDE SIX (6) COPIES OF SUBMITTAL MATERIAL WITH DESCRIPTIVE DATA FOR ALL PRODUCTS AND MATERIALS, INCLUDING BUT NOT LIMITED TO THE FOLLOWING, PRIOR TO INSTALLATION. ALL SUBMITTALS SHALL BE HIGHLIGHTED TO INDICATE SPECIFIC PRODUCTS OR MATERIALS BEING USED. B. SHOP DRAWINGS: 1.SUBMIT PRIOR TO INSTALLATION. 2.COORDINATED LAYOUT PLANS, SHOWING WORK OF ALL TRADES, INCLUDING BUT NOT LIMITED TO DUCTWORK; HVAC, PLUMBING, FIRE PROTECTION PIPING; ELECTRICAL CONDUITS AND BUS DUCTS; EQUIPMENT. 3.PANELBOARDS: DIMENSIONS, SCHEDULES AND CATALOG CUTS. 4.WALL SWITCHES. 5.INSERTION RECEPTACLES. 6.DIMMER SWITCHES. 7.DEVICE PLATES. 8.POKE-THROUGHS. 9.LIGHTING FIXTURES WITH BALLAST/TRANSFORMER INFORMATION. IN ADDITION TO COMPLYING WITH ALL OTHER LEGAL REQUIREMENTS, COMPLY WITH CURRENT PROVISIONS OF GOVERNING CODES AND REGULATIONS IN EFFECT DURING THE PROGRESS OF THE WORK, AND WITH THE FOLLOWING: 1.DRAWINGS AND SPECIFICATION REQUIREMENTS SHALL GOVERN WHERE THEY EXCEED CODE AND REGULATION REQUIREMENTS. 2.WHERE REQUIREMENTS BETWEEN GOVERNING CODES AND REGULATIONS VARY, THE MORE STRINGENT SHALL APPLY. 3.NOTHING CONTAINED IN CONTRACT DOCUMENTS SHALL BE CONSTRUED AS AUTHORITY OR PERMISSION TO DISREGARD OR VIOLATE LEGAL REQUIREMENTS. THE CONTRACTOR SHALL IMMEDIATELY DRAW THE ATTENTION OF THE ARCHITECT TO ANY SUCH CONFLICTS NOTED IN THE CONTRACT DOCUMENTS. 75-15270-01 03/31/2016 1.02 PRINCIPAL WORK IN THIS SECTION A. GENERAL REQUIREMENTS: 1.RELATED DOCUMENTS: ARCHITECTURAL SPECIFICATIONS, LIGHTING FIXTURE SPECIFICATION PACKAGE, GENERAL, SPECIAL AND SUPPLEMENTARY CONDITIONS, SHALL FORM A PART OF THESE SPECIFICATIONS. 2.SCOPE OF WORK: PROVIDE ALL REQUIRED LABOR, MATERIALS, EQUIPMENT AND CONTRACTOR'S SERVICES NECESSARY FOR COMPLETE AND SAFE INSTALLATION OF ELECTRICAL WORK IN CONFORMITY WITH REQUIREMENTS OF ALL AUTHORITIES HAVE JURISDICTION; AS INDICATED ON DRAWINGS AND/OR HEREIN SPECIFIED OR DESCRIBED. 3.DAMAGE TO OTHER WORK: REPAIR ANY DAMAGE CAUSED BY THIS SECTION TO WORK OF OTHER SECTIONS. 4.DAMAGE TO FIREPROOFING: REPAIR ANY DAMAGED FIREPROOFING CAUSED BY THIS SECTION TO INTEGRITY OF ORIGINAL CONSTRUCTION. 5.SITE SAFETY: CONTRACTOR COVENANTS AND AGREES THAT HE AND HIS SUBCONTRACTORS AND HIS AND THEIR AGENTS, SERVANTS AND EMPLOYEES WILL PROVIDE AND MAINTAIN A SAFE PLACE TO WORK AND THAT HE AND THEY WILL COMPLY WITH ALL LAWS AND REGULATIONS OF ANY GOVERNMENTAL AUTHORITY HAVING JURISDICTION THEREOF, AND CONTRACTOR AGREES TO INDEMNIFY, DEFEND AND HOLD HARMLESS, ENGINEER, OWNER AND ARCHITECT FROM AND AGAINST ANY LIABILITY, LOSS, DAMAGE OR EXPENSE, INCLUDING ATTORNEY'S FEES, ARISING FROM A FAILURE OR ALLEGED FAILURE ON THE PART OF CONTRACTOR, THIS SUBCONTRACTORS AND HIS AND THEIR AGENTS, SERVANTS AND EMPLOYEES TO PROVIDE AND MAINTAIN A SAFE PLACE TO WORK OR TO COMPLY WITH ALL LAWS AND REGULATIONS OF ANY GOVERNMENTAL AUTHORITY HAVING JURISDICTION THEREOF. 6.VERIFICATION OF EXISTING: BEFORE SUBMITTING BID, BECOME THOROUGHLY FAMILIAR WITH ACTUAL EXISTING CONDITIONS AND OF THE PRESENT INSTALLATIONS TO WHICH CONNECTIONS MUST BE MADE OR WHICH MUST BE CHANGED OR ALTERED. THE INTENT OF THE WORK IS SHOWN ON THE DRAWINGS AND DESCRIBED HEREIN, AND NO CONSIDERATION WILL BE GRANTED BY REASON OF LACK OF FAMILIARITY ON THE PART OF THE CONTRACTOR WITH ACTUAL PHYSICAL CONDITIONS, REQUIREMENTS, AND PRACTICES AT THE SITE. 7.REQUIREMENTS OF OTHER SECTIONS: CAREFULLY CHECK THE DOCUMENTS OF OTHER SECTIONS TO ASCERTAIN THE REQUIREMENTS OF ANY INTERFACING MATERIALS OR EQUIPMENT BEING FURNISHED AND/OR INSTALLED BY THAT SECTION WHICH RELATE TO THIS SECTION, AND PROVIDE THE PROPER INSTALLATION AND/OR CONNECTION. 8.INFORMATION TRANSFER: TRANSMIT ALL INFORMATION REQUIRED FOR WORK BEING PERFORMED BY OTHER SECTIONS IN AMPLE TIME FOR THE PROPER INSTALLATION AND CONNECTION, AND FOR THE PROVISION OF ALL OPENINGS REQUIRED IN FLOORS AND WALLS. 9.HOLES AND STRUCTURE: FIELD DRILLING AND CUTTING OF HOLES IN BUILDING STRUCTURE REQUIRED FOR WORK UNDER THIS SECTION SHALL BE COORDINATED THROUGH THE GENERAL CONTRACTOR AND APPROVED BY OWNER AND BUILDING STRUCTURAL ENGINEER. ALL SUCH CO-ORDINATION, DRILLING, CUTTING AND REINFORCING COSTS SHALL BE BORNE BY THIS CONTRACTOR. 10. SLEEVES: FURNISH AND SET ALL SLEEVES FOR THE PASSAGE OF CONDUIT THROUGH WALLS, ROOF AND FLOORS AND ELSEWHERE AS WILL BE REQUIRED FOR THE PROPER PROTECTION OF EACH CONDUIT PASSING THROUGH BUILDING SURFACES. COORDINATE THIS WORK WITH THE GENERAL CONTRACTOR IN ORDER TO PROPERLY EXPEDITE AND PERFORM THIS WORK. 11. PASSAGE OF EQUIPMENT: CHECK THE DIMENSIONAL REQUIREMENTS OF EQUIPMENT OF THIS SECTION TO ENSURE THAT SUCH EQUIPMENT CAN PASS THROUGH THE NECESSARY AREAS TO REACH ITS ULTIMATE INSTALLED LOCATION. INCLUDE IN BID COSTS FOR ALL WORK REQUIRED, INCLUDING ANY WORK REQUIRED TO MOVE THE EQUIPMENT THROUGH THE SITE TO THIS FINAL LOCATION, INCLUDING ANY DISMANTLING AND RE-ASSEMBLY. 12. FIRE/SMOKE DAMPER ASSEMBLIES: VERIFY EXACT LOCATIONS WITH THE MECHANICAL DRAWINGS. PROVIDE LINE VOLTAGE MOTOR CONNECTIONS AND LOCAL DISCONNECT SWITCHES AS REQUIRED. PROVIDE AND CONNECT DUCT AND/OR AREA SMOKE DETECTORS AS REQUIRED FOR ACTUATION OF THE DAMPER MOTORS. 13. SIGNAGE: PROVIDE SIGNAGE REQUIRED BY CODES AND AUTHORITIES HAVING JURISDICTION. 14. GUARANTEE: SUBMIT A SINGLE GUARANTEE STATING THAT ALL PORTIONS OF THE WORK ARE IN ACCORDANCE WITH CONTRACT REQUIREMENTS. GUARANTEE ALL WORK AGAINST FAULTY AND IMPROPER MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE BY OWNER, EXCEPT THAT WHERE GUARANTEES OR WARRANTIES FOR LONGER TERMS ARE SPECIFIED BY CONTRACT, SUCH LONGER TERM SHALL APPLY. 15. RECTIFICATION: AT NO ADDITIONAL COST TO THE OWNER, WITHIN 24 HOURS AFTER NOTIFICATION, CORRECT ANY DEFICIENCIES WHICH OCCUR DURING THE GUARANTEE PERIOD, ALL TO THE SATISFACTION OF THE OWNER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE CAUSED BY SUCH DEFICIENCIES AND REPAIR THEREOF AND REIMBURSE THE OWNER FOR ALL COSTS INCURRED. B. GENERAL ITEMS: 1.ACCESS DOORS/PANELS: PROVIDE CONCEALED OUTLET, JUNCTION BOXES AND EQUIPMENT REQUIRING ACCESS WITH ADEQUATELY SIZED ACCESS DOORS/PANELS. IN REMOVABLE TYPE CEILING, PROVIDE ACCESS TILE IDENTIFICATION ONLY. 2.CUTTING AND PATCHING FOR ELECTRICAL WORK. B. ELECTRICAL SPECIFICATIONS 1.01 GENERAL REQUIREMENTS A. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 1 SPECIFICATION SECTIONS, APPLY TO THIS SECTION. E0.1 ELECTRICAL SPECIFICATIONS GENERAL NOTES A. PROVIDE ALL ITEMS SHOWN FULL-TONE. B. ALL ITEMS SHOWN AS EXISTING '(E)' ARE PROVIDED AS PART OF PRE-WIRED MODULAR BUILDING. ITEMS SHOWN AS NEW '(N)' SHALL BE PROVIDED WITH NEW CONDUIT ROUTING AND DEVICES IN FIELD UPON INSTALLATION OF MODULAR BUILDING. 1 PROVIDED REMOTE EQUIPMENT CABINET FOR NETWORK SWITCH. HUBBELL RE2 OR EQUAL. PROVIDE PATCH PANEL FOR HORIZONTAL CABLING. TERMINATE ALL DATA RECEPTACLES IN PORTABLE AT PATCH PANEL. INSTALL DISTRICT PROVIDED SWITCH IN CABINET. PROVIDE FIBER FROM SWITCH TO NEAREST IDF ROOM (CONFIRM WITH DISTRICT) VIA UNDERGROUND CONDUITS. CONFIRM FIBER STANDARDS WITH DISTRICT. 2 PROVIDED DUPLEX RECEPTACLE WITH INTEGRAL 5V POWER SUPPLY TO POWER HDMI OVER UTP PLATE. HUBBELL #AVPS15W OR EQUAL. PROVIDE FACEPLATES WITH HDMI AND USB OVER TWISTED PAIR. PROVIDE CAT6 WIRING BETWEEN DEVICES. 'SB' DEVICE INDICATES OUTPUT PLATE AND 'AV' INDICATES INPUT PLATE. PROVIDE 5V POWER TO DEVICE FROM ADJACENT RECEPTACLE. 3 WAP (N) (E) FEEDER FROM PANEL 'TDBL'. REFER TO SHEET E1.0 FOR CONTINUATION. 3/31/2016 10:41:25 PM C:\Revit\75-15270-01_MEP_2015_Cental_tfritson.rvt ENLARGED POWER / DATA PLAN - BUILDING 4 SCALE: 1/4" = 1'-0" PANEL A 2 5 (N) (E) E2.1 ENLARGED POWER / DATA PLAN - BUILDING 3 SCALE: 1/4" = 1'-0" J (N) 2 (N) WAP PANEL PROVIDED WITH PRE-MANUFACTURED PORTABLE BUILDING. REFER TO ARCHITECTURAL PLANS FOR PANEL SIZE, SCHEDULE, AND EXACT LOCATION. 1 FEEDER FROM PANEL 'TDBL'. REFER TO SHEET E1.0 FOR CONTINUATION. 3 4 WAP PANEL PROVIDED WITH PRE-MANUFACTURED PORTABLE BUILDING. REFER TO ARCHITECTURAL PLANS FOR PANEL SIZE, SCHEDULE, AND EXACT LOCATION. 5 CLOCK PROVISIONS PROVIDED WITH MODULAR BUILDING. 2 2 WAP 1 2 +70" AFF (N) (N) (E) 3 PANEL A 2 1 5 (N) (E) FEEDER FROM PANEL 'TDBL'. REFER TO SHEET E1.0 FOR CONTINUATION. 2 E2.1 ENLARGED POWER / DATA PLAN - BUILDING 2 SCALE: 1/4" = 1'-0" PANEL PROVIDED WITH PRE-MANUFACTURED PORTABLE BUILDING. REFER TO ARCHITECTURAL PLANS FOR PANEL SIZE, SCHEDULE, AND EXACT LOCATION. PANEL A 2 (E) FEEDER FROM PANEL 'TDBL'. REFER TO SHEET E1.0 FOR CONTINUATION. 1 E2.1 ENLARGED POWER / DATA PLAN - BUILDING 1 SCALE: 1/4" = 1'-0" , DLR Group inc., SELECT STATE project is IN, ALL RIGHTS RESERVED 2 4 2 2 (N) CLOCK PROVISIONS PROVIDED WITH MODULAR BUILDING. SB (N) 2 (E) 3 2 +70" AFF (E) SB J J SB SB 4 (N) PANEL PROVIDED WITH PRE-MANUFACTURED PORTABLE BUILDING. REFER TO ARCHITECTURAL PLANS FOR PANEL SIZE, SCHEDULE, AND EXACT LOCATION. PANEL A (N) CLOCK PROVISIONS PROVIDED WITH MODULAR BUILDING. 2 2 2 (E) 3 2 +70" AFF (E) J 2 (N) CLOCK PROVISIONS PROVIDED WITH MODULAR BUILDING. 2 2 (E) (E) WAP E2.1 2 2 (E) © 2 (E) (N) WAP Revisions WAP Interim Housing 4 (N) (N) 2 4 2 5 (E) 4 2 1 AV 4 (E) 4 2 3 2 (E) 2 +70" AFF 2 3 2 3 (E) 3 2 (E) (N) AV 3 WAP 4 2 THIS IS A DEFAULT - Select State - THIS IS A DEFAULT 2 PROVIDE RECEPTACLE IN IDF CABINET FOR SWITCH. 75-15270-01 03/31/2016 (E) 5 ENLARGED POWER AND DATA PLANS AV PROVIDE FACEPLATES WITH HDMI AND USB OVER TWISTED PAIR. PROVIDE CAT6 WIRING BETWEEN DEVICES. 'SB' DEVICE INDICATES OUTPUT PLATE AND 'AV' INDICATES INPUT PLATE. PROVIDE 5V POWER TO DEVICE FROM ADJACENT RECEPTACLE. E2.1 2 4 FACP 2 FACP (E) FACP AV FACP 2 X Saugus Union School District - West Creek Academy KEYED NOTES BY SYMBOL - CONSTRUCTION DOCUMENTS LEGEND NOTES GENERAL NOTES A. PROVIDE ALL ITEMS SHOWN FULL-TONE. B. ALL ITEMS SHOWN AS EXISTING '(E)' ARE PROVIDED AS PART OF PRE-WIRED MODULAR BUILDING. ITEMS SHOWN AS NEW '(N)' SHALL BE PROVIDED WITH NEW CONDUIT ROUTING AND DEVICES IN FIELD UPON INSTALLATION OF MODULAR BUILDING. C. PROVIDE ALL FIRE ALARM DEVICES, CONDUIT, AND FACP AS NEW. KEYED NOTES BY SYMBOL - SCALE: 1/4" = 1'-0" E3.1 ENLARGED FIRE ALARM PLAN - BUILDING 2 SCALE: 1/4" = 1'-0" 1 E3.1 HEAT DETECTOR IN CEILING SPACE ENLARGED FIRE ALARM PLAN - BUILDING 1 SCALE: 1/4" = 1'-0" Saugus Union School District - West Creek Academy WAP Interim Housing 15 J 2 HEAT DETECTOR IN CEILING SPACE , DLR Group inc., SELECT STATE project is IN, ALL RIGHTS RESERVED ENLARGED FIRE ALARM PLAN - BUILDING 3 WAP Revisions E3.1 HEAT DETECTOR IN CEILING SPACE © 3/31/2016 10:41:26 PM F 15 J F 15 J F I C:\Revit\75-15270-01_MEP_2015_Cental_tfritson.rvt I SCALE: 1/4" = 1'-0" 3 I E3.1 ENLARGED FIRE ALARM PLAN - BUILDING 4 WAP HEAT DETECTOR IN CEILING SPACE I 4 HEAT DETECTOR IN CEILING SPACE THIS IS A DEFAULT - Select State - THIS IS A DEFAULT I HEAT DETECTOR IN CEILING SPACE HEAT DETECTOR IN CEILING SPACE TYP. 75-15270-01 03/31/2016 I WAP 1 TYP. I HEAT DETECTOR IN CEILING SPACE FACP 1 TYP. ENLARGED FIRE ALARM PLANS 1 TYP. WAP 15 J 1 WAP REFER TO TABLE BELOW FOR FIRE ALARM WIRING SIZES. E3.1 WAP F F WAP F FACP FACP F I F X FACP 1 CONSTRUCTION DOCUMENTS LEGEND NOTES NOTE: PROVIDE ADDITIONAL GROUND RODS IN CONCRETE BOXES 72" O.C. AS NEEDED TO MEET 5 OHM REQUIREMENT EXTENDING SAME CONDUIT AND WIRE AND USING SAME CLAMPS. 5 OHM RESISTANCE TO GROUND MAXIMUM SHALL BE PROVIDED USING GROUND RODS ONLY, PRIOR TO THE CONNECTION OF CONDUIT AT ROD OR PANEL OR OTHER GROUND PATH. SIGNAL 48" 48" TYP. KNOCKOUT 20"x20" CAST IRON LOCKING COVER OR CAST IRON BOLT DOWN COVER LOCKING COVER POWER FINISH GRADE 3/4"∅ PULL IRON TYP. FOR ALL PULL BOXES CAST IRON FRAME GROUND CLAMP SEE DETAIL "A-1" GROUND CONNECTOR CONDUIT TO ROD WITH FEED THRU CABLE RACK TYP. 36" TYPICAL LAYOUT 21"MIN. COPPER ALLOY GROUND CLAMPS BY BURNDY 8"∅ CLAY SOIL PIPE FILL WITH SOIL SET PULL BOX 1" ABOVE TOP OF FINISHED GRADE FINISHED GRADE BRASS BURNDY GROUND CONNECTOR TYPE "GKP" @4'-0" c/c (4 MIN) WT=1344# MAX 4. CHECK RESISTANCE TO GROUND IF RESISTANCE EXCEEDS 25 OHMS, INSTALL ADDITOINAL GROUND RODS (CEC 250-56) AS REQUIRED WITH CONDUCTORS AS SHOWN, SEPARATED BY AT LEAST 6'-0" UNTIL RESISTANCE IS 25 OHMS OR LESS. SEE 21/S-0.03 FOR ADDITIONAL INFORMATION W=24",L=23",H=42" ICC ESR-1771 OR ICC ESR-1917 5. FIELD INSPECTOR SHALL WITNESS AND VERIFY THE GROUNDING TEST. TRANSFORMER PAD f'c=2,500 PSI 4" MIN (E) S.O.G. 3/4" x 10'-0" LONG COPPER CLAD GROUND ROD OR OTHER ELECTRODE, DETAIL 1 ON THIS SHEET. GROUND ROD GROUND WIRE 6" #4 REBAR 12" ON CENTER EACH WAY DEPTH AS REQUIRED GROUND WIRE 6" DRAIN COVER FLUSHE WITH FLOOR RIGID CONDUIT 4" PLAN VIEW OF GROUND CLAMP TO RIGID CONDUIT DETAIL "A" GROUND ROD PER SPECIFICATION 6" COMPACT SAND MIFARI 140NC 36" SECTION OF 6" CLAY PIPE 1 CONCRETE FOUNDATION RAMP 10% LOCALLY WITH A.C. TO JOIN PULLBOX. TRAFFIC COVER "T" CONDUIT FOR SEPARATE EQUIPMENT GROUNDING CONDUCTOR BONDED TO METAL BUILDING FRAME 1/2" EXPANSION ANCHORS TRANSFORMER RIGID CONDUIT PRE-CAST CONCRETE BOX. 19"x14" BROOKS #36HFI OR EQ. TOP VIEW . DETAIL "B" 3. ALL MODULES OF THE METAL FRAME BUILDING SHALL BE ELECTRICALLY BONDED WITH #8 SOLID COPPER. (ASSEMBLY BOLTING IS NOT AN ACCEPTABLE BONDING). FINISH FLOOR TYP. KNOCKOUT 8"x16" GROUND ROD AND PRE-CAST CONCRETE GROUND BOX DETAIL,SD-3.6 SCALE NONE 2 PRE-CAST CONCRETE PULLBOX DETAIL, SD-3.1 36" 48" NOTE: FOR STRUCTURAL SUPPORT DETAIL, SEE STRUCTURAL DRAWING DETAIL 21 IN SHEET NO. S-0.03. FOR ANY DISCREPANCY, SPECIFICATIONS IN STRUCTURAL DETAILS SHALL TAKE PRECEDENCE. 3/4" CRUSHED ROCK MIN. SIZE PULL BOX BASE DIMENSION x 48" DEEP, FILLED TO TOP SCALE NONE 3 PORTABLE CLASSROOM GROUNDING DETAIL SCALE NONE 4 SCALE NONE TRANSFORMER MOUNTING DETAIL (E) PLASTER FINISH ON EXT CONDUIT (3) 4" MAX. FASTEN UNISTRUT TO 2x4@16" MIN WOOD STUD WALL USING 3/8" LAG SCREW CTR @ STUD 1-1/2" EMBED INTO STUD NOT USED SCALE NONE NOT USED SCALE NONE 10 NOT USED SCALE NONE 6 NOT USED SCALE NONE 11 NOT USED SCALE NONE 7 8 EXPOSED CONDUIT SUPPORT DETAIL SCALE NONE THIS IS A DEFAULT - Select State - THIS IS A DEFAULT 3/31/2016 10:41:26 PM C:\Revit\75-15270-01_MEP_2015_Cental_tfritson.rvt E4.1 5 Interim Housing MIN. 7'-0" A.F.F Revisions UNISTUT #P1000 GALVANIZED CHANNEL 1 5/8" MIN. X 18" MIN. EVERY 10' 1-1/2" TO EDGE MIN. 75-15270-01 03/31/2016 (E) 2X WOOD STUD ELECTRICAL DETAILS RIGID STEEL CONDUIT PIPE CLAMPS UNISTUT #P1100 SERIES (TYPICAL) 9 NOT USED SCALE NONE 12 NOT USED SCALE - Saugus Union School District - West Creek Academy COOPER WIRE, SIZE AS REQUIRED 24" 1 1/2"C, 3#1, 1#8 (PWR) ADJACENT TO GROUND CONDUIT 2. BOND SEPARATE CONDUCTORS FROM GROUND ROD TO ELECTRICAL PANEL AND TO METAL BUILDING FRAME IN ADDITIONAL TO THE DETAIL ABOVE. BOND THE ELECTRICAL GROUND TO METAL WATER PIPE EMBEDDED AT LEAST 10 FT. INTO THE SOIL IF AVAILABLE. (CEC 250-104). , DLR Group inc., SELECT STATE project is IN, ALL RIGHTS RESERVED GROUND CONNECTOR BURNDY TYPE GKP SEE DETAIL "B" 1. SIZE OF CONDUCTORS SHALL COMPLY WITH CEC TABLE 250-122. PANEL BONDED TO GROUND CONDUCTOR ELECTRICAL PANEL NOTES: © 3/4"∅ x 10'-0" COPPER CLAD GROUND ROD 1/2"C RIGID CONDUIT WITH #8 CONDUCTOR ATTACHED TO WALL WITH 2-HOLE STRAPS USE A BARRIER OR PROVIDE SEPARATE NONMETALLIC 8" X 8" X 4" PULL BOX INSTALLED INSIDE SIGNAL PULL BOX TO ISOLATE FIRE ALARM SYSTEM CONSTRUCTION DOCUMENTS 1. IN THE PRECAST CONCRETE PULL BOXES FURNISH AND INSTALL CABLE RACKS ON WALLS INDICATED. EACH RACK SHALL BE EQUIPPED WITH THREE PORCELAIN CABLE HOLDERS ON A VERTICAL STEEL MOUNTING BAR. BOLT HOLES SHALL BE PRE-CAST PULL BOXES QUICKSET UTILITY VAULT SERIES TPB-1001 OR EQUAL WITH STAINLESS STEEL FLAT HEAD SCREWS AND SELF CLEANING HOLES. LOOP ALL CABLES AROUND THE LONGEST LENGTH IN THE PULL BOX. BLDG 1 PANEL BLDG 2 PANEL BLDG 3 PANEL BLDG 4 PANEL 5 3. FEEDER LENGTH SHOWN ARE FOR SHORT CIRCUIT CALCULATION AND PLANCHECK PURPOSE ONLY. 4. ALL NEW CIRCUIT BREAKERS SHALL BE FULLY RATED, UNLESS OTHERWISE INDICATED. 5. ALL TERMINATIONS AND ENCLOSURES SHALL BE RATED FOR USE WITH 75 DEGREE CELCIUS CONDUCTORS 6. ELECTRICAL CONTRACTOR SHALL PERFORM SHORT CIRCUIT AND ARC FLASH STUDY NECESSARY FOR THE NEW SWITCHGEAR. PROVIDE ARC FLASH WARNING LABEL STICKERS AT ALL PANELS. 7. ALL ROUTING SHOWN ON ELECTRICAL DRAWINGS ARE DIAGRAMMATIC. CONTRACTOR TO VERIFY IN THE FIELD EXACT LOCATIONS OF FINAL ROUTING PRIOR TO INSTALLATION. 8. PROVIDE ARC-FLASH WARNING PLAQUE SHOW ABOVE ON EVERY SWITCHBOARD, INDUSTRIAL CONTROL PANEL, MOTOR CONTROL CENTER, ON THIS PROJECT PER NEC 110-16. KEYED NOTES BY SYMBOL DISTRIBUTION "TDBL" WP 100A 2P 400A 3P 1 Ph:a,b 100A 2P 2 Ph:a,c 100A 2P 3 Ph:b,c 100A 2P 100A 2P 4 5 Ph:a,b Ph:a,c 6 (E) FEEDER 208/120V DISTRIBUTION 1 1 (E) FEEDER 1 40A 3P 2 40A 3P 4 5 200AS 175AF 3P WP 1 40A 3P 2 175A 3P 90A 3P 6 (N) XFMR 480V-120/240V, HI LEG, 3PH 112.5KVA WP (E) FEEDER 1 7 FEEDER 4W MARK (E) XFMR 480-120/240V 3PH, 4W 112.5KVA (E) MAU 1 (E) FEEDER 1 40A 3P 3 (E) AC 4 (E) FEEDER (E) FEEDER 1 100A 3P 400A 3P (E) AC 3 EXISTING BREAKERS IN EXISTING SWITCHBOARD. 2 PROVIDE BREAKER TO MATCHING EXISTING BREAKERS TYPE AND EXISTING OR HIGHER AIC RATING. 3 PROVIDE 1#1/0 CU IN 1"C AND PROVIDE AND CONNECT TO A 3/4"D X 8' LONG GROUNDING ELECTRODE. 4 100A, 120/240 V, 1∅, 3W PANELS BY MODULAR BUILDING MANUFACTURER WITH 100A MAIN CIRCUIT BREAKER, SHOWN FOR REFERENCE ONLY. 5 CONDUIT TO BE STBBED AND CAPPED FOR FUTURE BUILDING. 6 42 CIRCUITS, 400A, FULLY RATED, 240/120V, 3∅, 4W B HILEG, 18 KAIC, WITH 400A/3P MCB, BOTTOM GED 175A 3P 8 FEEDER 3W MARK (AMPACITY) # SETS ø&N GND C (AMPACITY) # SETS ø GND C F415 1 12 12 3/4" F315 1 12 12 3/4" F420 1 12 12 3/4" F320 1 12 12 3/4" F430 1 10 10 3/4" F330 1 10 10 3/4" F440 1 8 10 1" F340 1 8 10 3/4" F450 1 6 10 1" F350 1 6 10 1" F460 F470 1 1 4 4 10 8 1 1/4" 1 1/4" F360 F370 1 1 4 4 10 8 1" 1 1/4" F480 1 3 8 1 1/4" F380 1 3 8 1 1/4" F490 1 2 8 1 1/2" F390 1 2 8 1 1/4" F4100 1 1 8 1 1/2" F3100 1 1 8 1 1/2" F4110 1 1 6 1 1/2" F3110 1 1 6 1 1/2" F4125 1 1/0 6 2" F3125 1 1/0 6 1 1/2" F4150 1 1/0 6 2" F3150 1 1/0 6 1 1/2" F4175 1 2/0 6 2" F3175 1 2/0 6 2" F4200 1 3/0 6 2" F3200 1 3/0 6 2" F4225 1 4/0 4 2 1/2" F3225 1 4/0 4 2" F4250 1 250 4 3" F3250 1 250 4 2 1/2" F4300 1 350 4 3" F3300 1 350 4 3" F4400 2 3/0 3 2 1/2" F3300 2 3/0 3 2" F4450 2 4/0 3 2 1/2" F3350 2 4/0 3 2" F4500 2 250 2 3" F3500 2 250 2 2 1/2" F4600 2 350 1 3" F3600 2 350 1 3" F4700 2 500 1/0 4" F3700 2 500 1/0 3-1/2" F4800 3 300 1/0 3" F3800 3 300 1/0 2 1/2" F41000 3 400 2/0 3" F31000 3 400 2/0 3" F41200 4 350 3/0 3-1/2" F31200 4 350 3/0 3" F41600 5 400 4/0 3-1/2" F31600 5 400 4/0 3" F42000 6 500 250 4" F32000 6 500 250 3-1/2" F42500 7 500 350 4" F32500 7 500 350 3-1/2" F43000 8 500 400 4" F33000 8 500 400 3-1/2" E5.1 1 (E) AC 2 (E) FEEDER (E) FEEDER (E) FEEDER (E) DISTRIBUTION "AHD-1" 277/480V-3PH-4W 400A BUS AIC=42K (E) AC 1 1 3ø FEEDER SCHEDULE (COPPER) 3 (E) PANEL 1AH X Interim Housing 4 WHERE EXISTING PANELBOARDS, TRANSFORMERS, ETC ARE SHOWN WITH NEW FEEDER CONNECTION, CONTRACTOR SHALL REMOVE EXISTING FEEDER TO EQUIPMENT AND CONNECT WITH NEW AS INDICATED. Revisions 4 2. 75-15270-01 03/31/2016 4 ALL PANEL BOARDS SHALL BE CAMPUS STANDARDS WITH BOLT-ON CIRCUIT BREAKER AND COPPER BUS. ELECTRICAL ONE-LINE DIAGRAM 4 1. Saugus Union School District - West Creek Academy GENERAL NOTES CONSTRUCTION DOCUMENTS LEGEND NOTES NOTES LEGEND FEEDER SHALL BE 4-WIRE (4W) UNLESS DENOTED OTHERWISE. ALL FEEDERS SHALL HAVE AN EQUIPMENT GROUND CONDUCTOR. TO & FROM CAMPUS MAIN SWITCHBOARD NOT ALL SIZES USED NEW ELECTRICAL CONDUIT TO BE INSTALLED TRANSFORMER FEEDER TABLE (COPPER) EXISTING ELECTRICAL CONDUIT GENERAL PURPOSE TRANSFORMERS FT15 4#6,#8G-1"C 60A #8 50A 4#1,#6G-1 1/2"C 100A #6 3#4,#8G-1 1/4"C 70A 4#1/0,#6G-2"C 150A #6 3#1,#8G-1 1/2"C 100A 4#4/0,#2G-2 1/2"C 225A #2 3#1/0,#6G-2"C 150A (2)2"C EACH WITH 4#3/0, #1/0G PARALLEL FEEDER 400A #1/0 150 3#4/0,#2G-2 1/2"C 225A (2)3"C EACH WITH 4-250Kcmil, #1/0G-PARALLEL FEEDER 500A #1/0 225 3-350Kcmil,#2G-3"C 300A (2)3"C EACH WITH 4-350Kcmil, #2/0G-PARALLEL FEEDER 650A #2/0 15 3#10,#10G-3/4"C 30A FT30 30 3#6,#10G-1"C FT45 45 FT75 75 FT112.5 112.5 FT150 FT225 SEC (SECONDARY) FT15K 15 3#10,#10G-3/4"C 30A 3#4,#2(N),#8G-1 1/2"C 60A #8 FT30K 30 3#6,#10G-1"C 50A 3#1/0,#3/0(N),#6G-2 1/2"C 100A #6 FT45K 45 3#4,#8G-1 1/4"C 70A 3#3/0,#250Kcmil(N),#4G-2 1/2"C 150A #4 FT75K 75 3#1,#8G-1 1/2"C 100A 3-300Kcmil,2#4/0(N),#1/0G-3"C 225A #1/0 * GEC (GROUNDING ELECTRODE CONDUCTOR PER NEC 250-66) , DLR Group inc., a California corporation, ALL RIGHTS RESERVED GEC CB © CB PRI (PRIMARY) Architecture Engineering Planning Interiors KVA K4-RATED TRANSFORMERS 3/31/2016 10:41:27 PM C:\Revit\75-15270-01_MEP_2015_Cental_tfritson.rvt ROOM SEPARATION LINE MARK