CPH C OMMERCIAL 3- TO 5-TON SELF-CONTAINED PACKAGED HEAT PUMP P RODUCT S PECIFICATIONS The new Goodman® CPH 13 SEER Commercial Packaged Heat Pump feature the environmentally friendly refrigerant R-410A, which is chlorine-free to help prevent damage to the ozone layer. Other features include a high-efficiency scroll compressor and a high-capacity, steel-cased filter dryer. These units are housed in a heavy-gauge, galvanized-steel cabinet with UV-resistant power-paint finish. Standard Features 13 SEER / 11.3 EER 7.7 HSPF SINGLE-PHASE & THREE-PHASE • • • • • • • • • • • • Environmentally friendly R-410A refrigerant High-efficiency scroll compressor Copper tube / aluminum fin coils Contactor with lugs High-capacity, steel-cased filter dryer Single-point entry 24-volt terminal strip Convertible Easy to service Built-in filter rack with standard 2” filters Bottom utility entry ARI Certified; ETL Listed Cabinet Features COOLING CAPACITY: 35,000 — 59,500 BTU/H HEATING CAPACITY: 35,000 — 58,500 BTU/H • Heavy-gauge, galvanized-steel cabinet with UVresistant powder-paint finish • Full Perimeter Rail • Curb Fit Contents Nomenclature................................................. 2 Product Specifications................................. 3 Airflow Data .................................................... 6 Expanded Heating Data ...........................11 Heat Kit Electrical Data .............................12 Expanded Cooling Data ............................15 Dimensions....................................................21 Wiring Diagrams .........................................26 Accessories ...................................................36 SS-CPH36-60 www.goodmanmfg.com 7/08 Supersedes 5/08 PRODUCT SPECIFICATIONS NOMENCLATURE C 1 P 2 H 3 060 4,5,6 070 7,8,9 1 10 D 11 X 12 X 13 X 14 Factory-Installed Options (Coming Soon) Special Features X No Features Brand C Commercial Configuration P Packaged Multi-Position X Application C Cooling G Gas Heat H Heat Pump Economizer Options (Factory Installed) X No Economizer Supply Fan/Drive Type/Motor B Belt Drive D Direct Drive H High-Static Belt Drive Nominal Gross Cooling Capacity 036 3 Tons 120 10 Tons 048 4 Tons 150 12½ tons 060 5 Tons 180 15 Tons 072 6 Tons 240 20 Tons 090 7½ Tons 300 25 Tons 102 8½ Tons Heating Capacity CPG 070 70,000 BTU/h 105 105,000 BTU/h 140 140,000 BTU/h 210 210,000 BTU/h 350 350,000 BTU/h 400 400,000 BTU/h 2 Special Treatment No Treatment/ Standard Aluminized Heat Exchanger (AH) 1 208v 1 Phase 2 220/240V 1 Phase 5 3 208v 3 Phase 4 5 7 Voltage 460v 3 Phase 380/415v 3 Phase 50 Hz 575v 3 Phase CPC/CPH XXX No Heat 010 10 kW Electric Heater 015 15 kW Electric Heater 020 20 kW Electric Heater 025 25 kW Electric Heater www.goodmanmfg.com SS-CPH36-60 PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS — 3 TONS Cooling Capacity Total BTU/h Sensible BTU/h SEER / EER IPLV Decibels ARI Reference #s Heating Capacity BTU/h - COP (47° F) BTU/h - COP (17° F) HSPF Evaporator Motor / Coil Motor Type # of Wheels (D x W) Indoor Nominal CFM Motor Speed Tap (Cooling) Indoor Motor FLA (Cooling) Horsepower - RPM Piston Size (Cooling) Expansion Device Filter Size Drain Size (NPT) R-410A Refrigerant Charge Cir #1(oz.) Evaporator Coil Face Area (ft²) Rows Deep/ Fins per Inch Belt Drive Evap Fan Data # of Wheels (D x W) Motor Sheave Blower Sheave Belt Condenser Fan / Coil Quantity of condenser Fan Motors Horsepower - RPM Fan Diameter/ # Fan Blades Outdoor Nominal CFM Face Area (ft²) Rows Deep/ Fins per Inch Piston Size (Heating) Electrical Data Voltage/Phase/ Frequency Quantity of Compressors Compressor RLA / LRA Indoor Blower HP / FLA Outdoor Fan HP / FLA Total Unit Amps Min. Circuit Ampacity¹ Max. Overcurrent Protection (amps)² Entrance Power Supply Entrance Control Voltage Operating Weight (lbs) Ship Weight (lbs) CPH036 ***1D*** CPH036 ***3D*** CPH036 ***3B*** CPH036 ***4B*** CPH036 ***7B*** 35,000 25,900 13 / 11.3 12.30 76.7 3012031 35,000 25,900 13 / 11.3 12.30 76.7 3009015 35,000 25,900 13 / 11.3 12.30 76.7 3009015 35,000 25,900 13 / 11.3 12.30 76.7 3009016 35,000 25,900 13 / 11.3 12.30 76.7 3009017 35,000 - 3.4 20,800 / 2.3 7.7 35,000 - 3.4 20,800 / 2.3 7.7 35,000 - 3.4 20,800 / 2.3 7.7 35,000 - 3.4 20,800 / 2.3 7.7 35,000 - 3.4 20,800 / 2.3 7.7 Direct Drive 1 (10” x 9”) 12,00 Low Speed 2.50 ⅓ - 890 0.068 Orifice ( 4) 14”x20”x2” ¾” 105.0 5.4 3 / 16 Direct Drive 1 (10” x 9”) 12,00 Low Speed 2.50 ⅓ - 890 0.068 Orifice ( 4) 14”x20”x2” ¾” 105.0 5.4 3 / 16 Belt Drive 1 (11” x 10”) 12,00 --3.8 1.0 - 1725 0.068 Orifice ( 4) 14”x20”x2” ¾” 105.0 5.4 3 / 16 Belt Drive 1 (11” x 10”) 12,00 --1.9 1.0 - 1725 0.068 Orifice ( 4) 14”x20”x2” ¾” 105.0 5.4 3 / 16 Belt Drive 1 (11” x 10”) 12,00 --2.3 1.5 - 1725 0.068 Orifice ( 4) 14”x20”x2” ¾” 105.0 5.4 3 / 16 1 (10” x 9”) ------- 1 (10” x 9”) ------- 1 (11” x 10”) 1VL40 X ⅝ AK69 X 1 AX41 1 (11” x 10”) 1VL40 X ⅝ AK69 X 1 AX41 1 (11” x 10”) 1VL40 X ⅝ AK69 X 1 AX41 1 ¼ / 1,090 22 / 4 3,800 18 1 / 22 0.055 1 ¼ / 1,090 22 / 4 3,800 18 1 / 22 0.055 1 ¼ / 1,090 22 / 4 3,800 18 1 / 22 0.055 1 ¼ - 890 22 / 4 3,800 18 1 / 22 0.055 1 ¼ - 1,075 22 / 4 3,800 18 1 / 22 0.055 208-230/1/60 1 16.7 / 79.0 ⅓ / 2.5 ¼ / 1.4 20.57 25 40 Locating Dimple Locating Dimple 208-230/3/60 1 10.5 / 73.0 ⅓ / 2.5 ¼ / 1.4 14.35 17 25 Locating Dimple Locating Dimple 208-230/3/60 1 10.5 / 73.0 1.0 / 3.8 ¼ / 1.4 15.65 18 25 Locating Dimple Locating Dimple 460/3/60 1 5.8 / 38.0 1.0 / 1.9 ¼ / 0.8 8.47 10 15 Locating Dimple Locating Dimple 575/3/60 1 3.8 / 36.5 1.5 / 2.3 ¼ / 0.6 6.68 8 10 Locating Dimple Locating Dimple 570 590 570 590 570 590 570 590 570 590 ¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ² May use fuses or HACR-type circuit breakers of the same size as noted. Note: Always check the S&R plate for electrical data on the unit being installed. SS-CPH36-60 www.goodmanmfg.com 3 PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS — 4 TONS Cooling Capacity Total BTU/h Sensible BTU/h SEER / EER Decibels ARI Reference #s Heating Capacity BTU/h (47° F) COP (47°F) BTU/h (17° F) COP (17°F) HSPF Evaporator Motor / Coil Motor Type Indoor Nominal CFM Motor Speed Tap (Cooling) Indoor motor FLA (Cooling) Horsepower - RPM Piston Size (Cooling) Filter Size Drain Size (NPT) R-410A Refrigerant Charge (oz.) Evaporator Coil Face Area (ft²) Rows Deep / Fins per Inch Belt Drive Evap Fan Data # of Wheels (D x W) Motor Sheave Blower Sheave Belt Condenser Fan / Coil Quantity of condenser Fan Motors Horsepower - RPM Fan Diameter / # Fan Blades Outdoor Nominal CFM Face Area (ft²) Rows Deep / Fins per Inch Piston Size (Heating) Electrical Data Voltage/Phase/ Frequency Quantity of Compressors Compressor RLA / LRA Max External Static Outdoor Fan RLA Total Unit Amps Min. Circuit Ampacity¹ Max. Overcurrent Protection (amps)² Entrance Power Supply Entrance Control Voltage Operating Weight (lbs) Ship Weight (lbs) CPH048 ***1D*** CPH048 ***3D*** CPH048 ***3B*** CPH048 ***4B*** CPH048 ***7B*** 46,000 34,500 13 / 11.3 77.7 3012030 46,000 34,500 13 / 11.3 77.7 3009018 46,000 34,500 13 / 11.3 77.7 3009018 46,000 34,500 13 / 11.3 77.7 3009019 46,000 34,500 13 / 11.3 77.7 3009020 46,000 3.4 26,500 2.3 7.7 46,000 3.4 26,500 2.3 7.7 46,000 3.4 26,500 2.3 7.7 46,000 3.4 26,500 2.3 7.7 46,000 3.4 26,500 2.3 7.7 Direct Drive 1,600 Medium 2.87 ½ - 1,000 0.076 ( 4) 14”x20”x2” ¾” 185.0 7.8 4 / 16 Direct Drive 1,600 Medium 2.87 ½ - 1,000 0.076 ( 4) 14”x20”x2” ¾” 185.0 7.8 4 / 16 Belt Drive 1,600 --3.8 1.0 - 1,725 0.076 ( 4) 14”x20”x2” ¾” 185.0 7.8 4 / 16 Belt Drive 1,600 --1.9 1.0 - 1,725 0.076 ( 4) 14”x20”x2” ¾” 185.0 7.8 4 / 16 Belt Drive 1,600 --2.3 1.5 - 1,725 0.076 ( 4) 14”x20”x2” ¾” 185.0 7.8 4 / 16 1 (10” x 9”) ------- 1 (10” x 9”) ------- 1 (11” x 10”) VL44 X 5/8 AK66 X 1 AX41 1 (11” x 10”) VL44 X 5/8 AK66 X 1 AX41 1 (11” x 10”) VL44 X 5/8 AK66 X 1 AX41 1 ¼ / 1,090 22 / 4 3,800 18.0 2 / 18 0.057 1 ¼ / 1,090 22 / 4 3,800 18.0 2 / 18 0.057 1 ¼ / 1,090 22 / 4 3,800 18.0 2 / 18 0.057 1 ¼ - 890 22 / 4 3,800 18.0 2 / 18 0.057 1 ¼ - 1,075 22 / 4 3,800 18.0 2 / 18 0.057 208-230/1/60 1 20 / 109 0.6” 1.40 24.1 29 45 Locating Dimple 585 605 208-230/3/60 1 13.1 / 83.1 0.6” 1.40 17.4 21 30 Locating Dimple 585 605 208-230/3/60 1 13.1 / 83.1 0.8” 1.40 18.3 22 30 Locating Dimple 585 605 460/3/60 1 6.1 / 41 0.8” 0.80 8.8 10 15 Locating Dimple 585 605 575/3/60 1 4.4 / 33 0.8” 0.60 7.3 8 10 Locating Dimple 585 605 ¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ² May use fuses or HACR-type circuit breakers of the same size as noted. Note: Always check the S&R plate for electrical data on the unit being installed. 4 www.goodmanmfg.com SS-CPH36-60 PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS — 5 TONS Cooling Capacity Total BTU/h Sensible BTU/h SEER / EER Decibels ARI Reference No. Heating Capacity BTU/h / COP (47° F) BTU/h / COP (17° F) HSPF Evaporator Motor Motor Type Indoor Nominal CFM Expansion Device Piston Size (Cooling) Filter Size Drain Size (NPT) R-410A Refrigerant Charge (oz.) Evaporator Coil Face Area (ft²) Rows Deep/ Fins per Inch Tube Diameter/ Material Evaporator Fan Standard Direct Drive (D x W) HP Standard Belt Drive (D x W) HP High-Static Belt Drive (D x W) HP Condenser Fan / Coil Horsepower / RPM Fan Diameter/ # Fan Blades Outdoor Nominal CFM Face Area (ft²) Rows Deep/ Fins per Inch Tube Diameter/ Material Piston Size (Heating) Electrical Data Voltage/ Frequency/ Phase Compressor RLA / LRA Indoor Blower HP / FLA Indoor Blower LRA Max External Static Outdoor Fan HP / RLA Min. Circuit Ampacity¹ Max. Overcurrent Protection (amps)² Entrance Power Supply Entrance Control Voltage Operating Weight (lbs) Ship Weight (lbs) CPH060 ***1D*** CPH060 ***3D*** CPH060 ***3B*** CPH060 ***4B*** CPH060 ***7B*** 59,500 42,500 13 / 11.3 77.2 1487345 59,500 42,500 13 / 11.3 77.2 1487471 59,500 42,500 13 / 11.3 77.2 1487471 59,500 42,500 13 / 11.3 77.2 1487469 59,500 42,500 13 / 11.3 77.2 1487470 58,500 / 3.65 33,000 / 2.50 7.7 58,500 / 3.65 33,000 7.7 58,500 / 3.65 33,000 7.7 58,500 / 3.65 33,000 7.7 58,500 / 3.65 33,000 / 2.50 7.7 Direct 2,000 Piston 0.082 14” x 20” x 2” ¾” 185 Direct 2,000 Piston 0.082 14” x 20” x 2” ¾” 185 Belt 2,000 Piston 0.082 14” x 20” x 2” ¾” 185 Belt 2,000 Piston 0.082 14” x 20” x 2” ¾” 185 Belt 2,000 Piston 0.082 14” x 20” x 2” ¾” 185 7.8 4 / 16 5 /16”/ Copper 7.8 4 / 16 5 /16”/ Copper 7.8 4 / 16 5 /16”/ Copper 7.8 4 / 16 5 /16”/ Copper 7.8 4 / 16 5 /16”/ Copper (11” X 10”) 1 ------- (11” X 10”) 1 ------- ---(11” X 10”) 1 (11” X 10”) 1½ ---(11” X 10”) 1 (11” X 10”) 1½ ---(11” X 10”) 1½ ---- ¼ / 1,090 22 / 4 3,800 17½ 2 / 18 5 /16”/ Copper 0.064 ¼ / 1,090 22 / 4 3,800 17½ 2 / 18 5 /16”/ Copper 0.064 ¼ / 1,090 22 / 4 3,800 17½ 2 / 18 5 /16”/ Copper 0.064 ¼ / 1,090 22 / 4 3,800 17½ 2 / 18 5 /16”/ Copper 0.064 ¼ / 1,075 22 / 4 3,800 17½ 2 / 18 5 /16”/ Copper 0.064 460 / 60 / 3 7.76 / 52 1.0 / 1.9 12 1.0 ¼ / 0.80 12 20 575-3-60 5.7 / 38.9 1.5 / 2.3 12 1.0 ¼ / 0.60 10 15 208-230 / 60 / 3 208-230 / 60 / 3 208-230 / 60 / 3 26.4 / 134 15.96 / 110 15.96 / 110 1.0 / 7.6 1.0 / 7.6 1.0 / 3.8 ------24 0.9 0.9 1.0 ¼ / 1.40 ¼ / 1.40 ¼ / 1.40 42 29 25 60 45 40 Locating Dimple Locating Dimple 590 610 590 610 Locating Dimple Locating Dimple 590 610 590 610 590 610 ¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ² May use fuses or HACR-type circuit breakers of the same size as noted. Note: Always check the S&R plate for electrical data on the unit being installed. SS-CPH36-60 www.goodmanmfg.com 5 PRODUCT SPECIFICATIONS AIRFLOW DATA — DIRECT DRIVE — 3 TONS Standard Direct Drive Motor — Down Shot Standard Direct Drive Motor — Horizontal Speed Tap CFM Static Amps Watts RPM Speed Tap Low 873 960 1017 1071 1120 1164 0.6 0.5 0.4 0.3 0.2 0.1 1.34 1.42 1.49 1.53 1.59 1.63 299 312 325 335 346 354 899 857 810 775 720 663 Low 852 1037 1135 1237 1307 1365 1422 1469 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 1.54 1.70 1.81 1.90 2.00 2.07 2.16 2.24 344 379 405 424 443 461 477 494 1032 987 963 934 904 869 834 792 Med 855 1096 1219 1299 1396 1487 1552 0.9 0.8 0.7 0.6 0.5 0.4 0.3 1.91 2.09 2.19 2.27 2.37 2.47 2.55 406 452 478 499 526 547 566 1081 1045 1022 999 981 957 934 High CFM Static Amps Watts RPM 878 979 1023 1088 1144 1207 0.6 0.5 0.4 0.3 0.2 0.1 1.35 1.44 1.51 1.56 1.61 1.62 300 320 330 340 350 353 892 839 792 745 692 639 925 1057 1164 1251 1324 1402 0.8 0.7 0.6 0.5 0.4 0.3 1.61 1.74 1.85 1.93 2.02 2.12 362 391 416 434 450 471 1011 975 943 914 881 851 Med 815 1072 1225 1330 1429 0.9 0.8 0.7 0.6 0.5 1.89 2.09 2.22 2.31 2.40 403 453 486 509 533 1070 1040 1011 987 966 High Notes Assumes dry coil with filter in place; SCFM correction for wet coil = 4% Standard Belt Drive Down-Shot ESP, In H 2O 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Turns Open CFM 1515 1272 0 RPM 976 982 BHP 0.46 0.38 CFM 1427 1201 1 RPM 923 923 BHP 0.38 0.32 CFM 1384 1138 2 RPM 870 876 BHP 0.33 0.27 CFM 3 RPM BHP 1553 1366 1094 816 816 823 0.34 0.29 0.23 CFM 4 RPM BHP 1515 1314 1098 764 764 768 0.3 0.24 0.2 CFM 4 RPM BHP 1406 1238 1039 766 769 769 0.27 0.23 0.19 CFM 1521 1356 1114 5 RPM 717 717 723 BHP 0.27 0.23 0.18 CFM 1393 1244 1045 5 RPM 713 713 717 BHP 0.24 0.21 0.17 Standard Belt Drive Horizontal ESP, In H 2O 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 6 Turns Open CFM 1386 1169 859 0 RPM 976 975 981 BHP 0.42 0.35 0.27 CFM 1506 1328 1131 1 RPM 924 929 929 BHP 0.41 0.35 0.31 CFM 1472 1290 1070 2 RPM 872 874 875 BHP 0.35 0.31 0.25 CFM 3 RPM BHP 1431 1268 1073 820 822 822 0.31 0.27 0.22 www.goodmanmfg.com SS-CPH36-60 PRODUCT SPECIFICATIONS AIRFLOW DATA — DIRECT DRIVE — 4 TONS Standard Direct Drive Motor — Down Shot CFM Static Watts RPM 1165 1307 1404 1495 1577 1659 1711 0.8 0.7 0.6 0.5 0.4 0.3 0.2 476 508 526 550 578 596 541 1014 980 954 925 898 865 832 1201 1358 1487 1589 1716 1820 0.9 0.8 0.7 0.6 0.5 0.4 560 594 620 642 668 692 1045 1021 997 979 956 932 Standard Direct Drive Motor — Horizontal Speed CFM Static Watts RPM Speed Med 1307 1404 1495 1577 1659 1711 1771 0.7 0.6 0.5 0.4 0.3 0.2 0.1 508 526 550 578 596 541 558 980 954 925 898 865 832 804 Med High 1285 1448 1551 1662 1705 1818 0.8 0.7 0.6 0.5 0.4 0.3 586 620 648 672 688 724 1035 1008 992 970 947 926 1867 0.2 734 903 Notes Table represents dry coil without filter. To account for filter 0.08” should be added to measured ESP. SCFM correction for wet coil = 4%. Four-ton models are shipped from the factory with speed tap set on medium speed. High Standard Belt Drive Down-Shot Turns Open ESP, In H 2O 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1.1 0 CFM RPM 1 BHP CFM RPM 2 BHP CFM RPM 3 BHP CFM RPM 4 5 CFM RPM BHP RPM BHP 1872 1720 0.52 1576 0.44 1334 0.37 887 887 892 892 1851 826 0.5 1665 831 0.45 1503 831 0.41 0.33 0.44 0.39 0.34 RPM BHP CFM RPM BHP RPM BHP 942 942 942 947 1839 0.54 1716 0.5 1617 0.47 1478 0.41 887 887 887 888 0.5 1706 832 0.45 1591 832 0.41 1445 837 0.37 0.4 0.37 0.32 1767 942 1818 992 0.59 1564 942 1624 997 0.51 1340 947 1739 1052 0.62 1423 1000 0.45 1842 1101 0.72 1551 1052 0.54 1653 1107 0.63 1316 1057 0.45 BHP CFM Standard Belt Drive Horizontal Turns Open ESP, In H 2O 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1.1 0 CFM 1862 1687 1548 1397 SS-CPH36-60 RPM 1 BHP CFM RPM 2 BHP CFM RPM 3 BHP CFM 1851 1730 1742 997 0.56 1631 1662 997 0.53 1477 1777 1052 0.64 1519 1001 0.48 1101 0.73 1646 1052 0.58 1369 1002 0.42 1107 0.65 1491 1052 0.52 1107 0.59 1112 0.54 www.goodmanmfg.com 4 5 CFM 7 PRODUCT SPECIFICATIONS AIRFLOW DATA — DIRECT DRIVE — 5 TONS STANDARD DIRECT DRIVE MOTOR, DOWN SHOT STANDARD DIRECT DRIVE MOTOR, HORIZONTAL Standard Cfm Static Amps Watts Rpm 765 820 905 965 1040 1120 1180 1255 1440 995 1060 1130 1190 1260 1315 1375 1445 1520 1675 1715 1785 1835 1895 1950 2005 2045 2030 1685 1725 1795 1835 1905 1990 2080 2150 2200 1910 1945 1985 2045 2090 2140 2190 2225 2275 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 2.15 2.05 2.00 1.90 1.80 1.70 1.60 1.50 1.70 2.60 2.60 2.45 2.40 2.30 2.20 2.05 2.00 1.90 4.90 4.70 4.60 4.50 4.40 4.20 4.05 3.95 3.80 5.40 5.30 5.15 5.05 4.95 4.80 4.70 4.50 4.40 6.10 5.95 5.90 5.75 5.57 5.50 5.30 5.20 5.10 245 230 225 215 200 180 175 160 180 310 300 290 270 260 240 220 220 205 615 590 580 560 540 530 510 490 470 690 665 665 640 635 600 590 565 545 810 790 775 750 730 705 685 665 640 910 870 830 790 730 690 645 595 580 935 905 855 810 765 730 680 645 595 1020 980 955 930 890 855 820 790 750 1030 1005 965 940 915 875 850 810 780 1065 1035 1005 975 940 915 880 850 820 Speed Tap T1 T2 T3 T4 T5 Standard Cfm Static Amps Watts Rpm 730 785 850 915 980 1055 1120 1190 1250 955 1000 1070 1120 1185 1255 1305 1360 1415 1575 1620 1670 1750 1780 1835 1870 1900 1950 1605 1660 1690 1735 1786 1855 1905 1925 2015 1805 1890 1935 1990 2020 2070 2100 2140 2170 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 2.20 2.00 2.00 1.95 1.90 1.75 1.70 1.60 1.50 2.70 2.60 2.55 2.45 2.40 2.30 2.15 2.00 2.00 4.85 4.75 4.70 4.60 4.50 4.40 4.30 4.20 4.05 5.75 5.65 5.51 5.36 5.24 5.15 5.10 4.95 4.85 6.00 6.10 6.05 5.95 5.85 5.70 5.65 5.55 5.40 260 235 230 210 205 200 185 175 150 325 305 295 285 270 260 245 230 220 630 620 600 600 570 555 545 525 500 735 705 690 680 665 650 640 635 600 800 810 800 785 765 755 740 720 710 920 890 850 815 780 730 680 635 595 960 925 895 855 805 770 725 685 655 1065 1035 1010 975 940 920 890 865 830 1090 1055 1030 1000 975 950 925 900 875 1115 1090 1065 1040 1020 985 965 940 915 Speed Tap T1 T2 T3 T4 T5 Notes Assumes dry coil with filter in place; SCFM correction for wet coil = 4% Five-ton models are shipped from the factory with speed tap set on T4. 8 www.goodmanmfg.com SS-CPH36-60 PRODUCT SPECIFICATIONS AIRFLOW DATA — BELT DRIVE — 5 TONS (CONT.) Standard Belt Drive — Down Shot Turns Open 0 1 2 3 CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM 2,399 2,317 1,008 0.75 2,172 2,627 1,157 1.06 2,498 1,115 0.94 2,310 1,066 0.79 2,040 1,014 0.69 1,868 2,392 1,162 1.02 2,215 1,121 0.87 2,025 1,071 0.73 1,752 1,019 0.63 1,465 2,154 1,173 0.93 1,920 1,126 0.78 1,665 1,077 0.65 1,748 1,184 0.83 1,569 1,135 0.7 1,199 1,084 0.56 1,371 1,190 0.74 1,077 1,143 0.62 ESP, In H 2O 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 4 RPM 951 956 961 965 BHP 0.69 0.65 0.59 0.52 CFM 2,213 1,924 1,557 5 RPM BHP 895 0.6 899 0.55 902 0.49 High-Static, Belt Drive — Down Shot Turns Open 0 1 2 3 4 5 CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP ESP, In H 2O 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 2,690 2,661 1,355 1.34 2,466 2,437 1,360 1.27 2,167 2,132 1,371 1.18 1,865 1,299 1,302 1,311 1,316 1.28 1.22 1.13 1.05 2,705 2,521 2,188 1,870 1,496 1,241 1,245 1,250 1,256 1,261 1.21 1.14 1.06 0.98 0.9 2,498 2,269 1,966 1,566 991 Standard Belt Drive — Down Shot 1.09 1.02 0.95 0.86 0.76 1,134 1,134 1,140 1,145 1,147 1,151 1.01 0.96 0.9 0.83 0.75 0.68 2,259 2,052 1,687 1,243 647 1,079 1,079 1,085 1,090 1,090 0.91 0.85 0.79 0.71 0.64 CPG060 High-Static, Belt Drive — Down Shot 1.8 1.8 1.6 1.6 1.4 Decreasing turns 1.4 Decreasing turns 1.2 ESP, In H 2O ESP, In H 2O 1,189 1,195 1,196 1,200 1,206 2,551 2,235 2,015 1,613 1,130 615 1 0.8 0.6 1.2 1 0.8 5 Turns 0.6 0.4 0.4 5 Turns 0.2 0.2 0 0 0 500 1,000 1,500 2,000 2,500 3,000 0 Airflow, CFM SS-CPH36-60 500 1,000 1,500 2,000 2,500 3,000 Airflow, CFM www.goodmanmfg.com 9 PRODUCT SPECIFICATIONS AIRFLOW DATA — BELT DRIVE — 5 TONS (CONT.) Standard Belt Drive — Horizontal Turns Open ESP, In H 2O 0 1 CFM RPM BHP CFM RPM BHP CFM 2,533 2,451 1,120 0.89 2,278 2,436 1,175 0.95 2,227 1,122 0.84 2,065 2,236 1,181 0.89 2,011 1,129 0.78 1,839 2,008 1,187 0.82 1,777 1,137 0.71 1,555 1,746 1,193 0.75 1,467 1,143 0.64 1,128 1,012 1,148 0.56 653 0.2 0.4 0.6 0.8 1 1.2 1.4 2 RPM 1,058 1,063 1,069 1,074 1,079 1,090 1,096 BHP 0.84 0.79 0.73 0.68 0.61 0.54 0.46 CFM 2,346 2,154 1,899 1,615 1,165 710 3 RPM 1,000 1,007 1,014 1,021 1,027 1,033 BHP 0.73 0.68 0.64 0.58 0.51 0.45 CFM 2,213 1,976 1,691 1,331 852 4 RPM 950 956 961 967 972 BHP 0.64 0.6 0.55 0.49 0.43 5 RPM 898 903 903 909 BHP 0.57 0.52 0.47 0.42 5 RPM 1,074 1,077 1,081 1,084 1,088 1,090 1,095 BHP 0.91 0.87 0.84 0.79 0.74 0.67 0.63 CFM 2,004 1,742 1,450 986 1.6 High-Static Belt Drive — Horizontal Turns Open 0 1 2 3 4 CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM 2,376 2,537 1,225 1.14 2,498 1,190 1.05 2,347 1,135 0.97 2,179 2,595 1,300 1.22 2,399 1,234 1.11 2,350 1,193 1.00 2,154 1,138 0.92 1,955 2,648 1,355 1.29 2,527 1,306 1.18 2,210 1,242 1.06 2,157 1,195 0.95 1,928 1,141 0.87 1,714 2,444 1,361 1.23 2,329 1,305 1.12 2,001 1,246 1.00 1,902 1,198 0.91 1,668 1,144 0.82 1,411 2,280 1,365 1.16 2,127 1,311 1.06 1,806 1,249 0.94 1,613 1,203 0.85 1,291 1,149 0.76 997 2,061 1,367 1.11 1,872 1,316 0.99 1,557 1,256 0.89 1,226 1,206 0.77 881 1,151 0.7 605 1,826 1,372 1.05 1,590 1,319 0.93 1,197 1,264 0.81 831 1,209 0.71 ESP, In H 2O 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 High-Static, Belt Drive — Horizontal 1.8 1.8 1.6 1.6 1.4 1.4 Decreasing turns 1.2 ESP, In H 2O ESP, In H 2O Standard Belt Drive — Horizontal 1 0.8 0.6 0.4 Decreasing turns 1.2 1 0.8 0.6 5 Turns 0.4 5 Turns 0.2 0.2 0 0 0 500 1,000 1,500 2,000 2,500 3,000 0 Airflow, CFM 10 500 1,000 1,500 2,000 2,500 3,000 Airflow, CFM www.goodmanmfg.com SS-CPH36-60 PRODUCT SPECIFICATIONS EXPANDED HEATING DATA 3 TONS Outdoor Ambient Temperature 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10 MBh 44.0 41.7 39.2 36.6 35.0 33.9 31.5 29.1 25.9 23.9 22.0 20.8 20.0 18.0 15.9 13.9 11.9 9.7 T/R 33.9 32.1 30.2 28.3 27.0 26.2 24.3 22.4 20.0 18.5 17.0 16.1 15.5 13.9 12.3 10.7 9.2 7.5 kW 3.20 3.14 3.08 3.02 2.98 2.96 2.90 2.84 2.81 2.75 2.69 2.66 2.63 2.57 2.51 2.45 2.39 2.33 Amps 10.9 10.2 9.6 9.2 8.9 8.8 8.4 8.0 7.7 7.5 7.2 7.1 7.0 6.7 6.4 6.1 5.8 5.4 COP 4.03 3.89 3.73 3.56 3.44 3.36 3.18 3.00 2.70 2.55 2.40 2.29 2.23 2.05 1.86 1.66 1.45 1.22 Hi Pr 404 388 373 356 348 341 328 315 302 288 277 270 265 255 245 235 227 219 Lo Pr 183 170 159 146 138 133 122 109 98 88 77 72 69 58 50 43 37 29 Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed. High pressure is measured at the liquid line gauge port connection Amps = unit amps (comp.+fans) Low pressure is measured at the compressor suction gauge port connection. kW = Total system power Design Super Heat 7°± 2 @ Suction Service Port 47 test condition 4 TONS Outdoor Ambient Temperature 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10 MBh 57.8 54.7 51.5 48.2 46.0 44.6 41.4 38.2 33.2 30.6 28.2 26.6 25.6 23.0 20.4 17.8 15.2 12.4 T/R 33.5 31.7 29.8 27.9 26.6 25.8 24.0 22.1 19.2 17.7 16.3 15.4 14.8 13.3 11.8 10.3 8.8 7.2 kW 4.03 3.96 3.88 3.81 3.77 3.73 3.66 3.59 3.39 3.32 3.25 3.21 3.18 3.11 3.04 2.97 2.90 2.83 COP 4.20 4.05 3.88 3.70 3.58 3.49 3.31 3.11 2.86 2.69 2.53 2.42 2.36 2.16 1.96 1.75 1.53 1.28 HI PR 409 392 377 360 352 345 332 319 305 291 280 273 268 258 248 238 230 221 LO PR 135 126 118 108 102 98 90 80 73 65 57 53 51 43 37 31 27 22 Above information is for nominal CFM and 70º F indoor dry bulb. Instantaneous capacity listed. Design Superheat 7°± 2 @ suction access fittings; 47º test condition 5 TONS Outdoor Ambient Temperature 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10 MBh 73.6 69.7 65.6 61.3 58.6 56.7 52.7 48.6 41.4 38.2 35.2 33.2 32.0 28.7 25.5 22.2 18.9 15.5 ∆T 33.2 31.5 29.6 27.7 26.4 25.6 23.8 22.0 18.7 17.3 15.9 15.0 14.5 13.0 11.5 10.0 8.6 7.0 kW 4.89 4.79 4.70 4.60 4.54 4.50 4.41 4.32 4.10 4.01 3.92 3.87 3.83 3.74 3.65 3.56 3.46 3.37 Amps 16.3 15.1 14.1 13.3 12.8 12.6 11.9 11.3 10.8 10.4 9.9 9.7 9.5 9.1 8.5 8.0 7.4 6.7 COP 4.41 4.26 4.09 3.90 3.77 3.69 3.50 3.30 2.95 2.79 2.63 2.52 2.44 2.25 2.04 1.83 1.60 1.35 EER 15.1 14.5 14.0 13.3 12.9 12.6 11.9 11.3 10.1 9.5 9.0 8.6 8.4 7.7 7.0 6.2 5.5 4.6 Hi Pr 407 390 375 358 350 343 330 317 304 290 278 272 267 257 247 237 228 220 Lo Pr 125 116 109 100 94 91 83 74 67 60 53 49 47 40 34 29 25 20 Calculations are based on nominal CFM and 70°F indoor dry bulb. kW = Total system power SS-CPH36-60 Design Super Heat 7°± 2 @ Suction Service Port 47 test condition Amps = Outdoor unit amps (comp.+ fan) www.goodmanmfg.com 11 PRODUCT SPECIFICATIONS HEAT KIT ELECTRICAL DATA (BLOWER ONLY, HEAT MODE) — 3 TONS Model and Heat Kit Usage MCA¹ @ 208 / 240V MOP² (amps) @ 208 / 240V Actual kW & BTU @ 240V Recommended Airflow Range CPH036***1D*** EHK1-10 EHK1-15 25 67 / 77 89 / 103 40 70 / 80 90 / 110 10 15 1250-1350 CFM 1400-1440 CFM CPH036***3D*** EHK3-10 EHK3-15 17 41 / 47 54 / 62 25 45 / 50 60 / 70 10 15 1250-1350 CFM 1400-1440 CFM CPH036***3B*** EHK3-10 EHK3-15 18 42 / 48 55 / 63 25 45 / 50 60 / 70 10 15 1250-1350 CFM 1400-1440 CFM MCA¹ @ 480V MOP² (amps) @ 480V Actual kW & BTU @ 480V Recommended Airflow Range 10 25 33 15 25 35 10 15 1250-1350 CFM 1400-1440 CFM MCA¹ @ 575V MOP² (amps) @ 575V Actual kW & BTU @ 575V Recommended Airflow Range 8 20 26 15 25 30 10 15 1400-1475 CFM 1575-1650 CFM Model and Heat Kit Usage CPH036***4B*** EHK4-10 EHK4-15 Model and Heat Kit Usage CPH036***7B*** EHK7-10 EHK7-15 ¹ Minimum Circuit Ampacity ² Maximum Overcurrent Protection device KW CORRECTION FACTORS kW Correction Factor for 1- & 3-Phase Units Supply Voltage Correction Factor 240 230 220 210 208 1 0.93 0.82 0.78 0.76 Minimum Airflow for Electric Heat kW Correction Factor for 480V Units Actual Voltage 460 440 430 Correction Factor 0.92 0.84 0.8 Heater Size (kW) Minimum CFM 10 1,250 15 1,400 For other voltage use voltage² / 480² kW Correction Factor for 575V Units Supply Voltage 560 550 540 Correction Factor 0.95 0.91 0.88 Multiply rated kW by correction factor to get actual kW 12 www.goodmanmfg.com SS-CPH36-60 PRODUCT SPECIFICATIONS HEAT KIT ELECTRICAL DATA (BLOWER ONLY, HEAT MODE) — 4 TONS Model and Heat Kit Usage MCA¹ @ 208 / 240V MOP² (amps) @ 208 / 240V Actual kW & BTU @ 240V Recommended Airflow Range CPH048***1D*** EHK1-10 EHK1-15 EHK1-18 29 70 / 81 93 / 107 107 / 123 45 80 / 90 100 / 110 110 / 125 10 15 18 1400-1800 CFM 1575-1800 CFM 1575-1800 CFM CPH048***3D*** EHK3-10 EHK3-15 EHK3-18 21 44 / 51 57 / 66 65 / 75 30 45 / 60 60 / 70 70 / 80 10 15 18 1400-1800 CFM 1575-1800 CFM 1575-1800 CFM CPH048***3B*** EHK3-10 EHK3-15 EHK3-18 22 45 / 52 58 / 67 66 / 76 30 45 / 60 60 / 70 70 / 80 10 15 18 1400-1800 CFM 1575-1800 CFM 1575-1800 CFM MCA¹ @ 480V MOP² (amps) @ 480V Actual kW & BTU @ 480V Recommended Airflow Range 10 25 33 37 15 30 35 40 10 15 18 1400-1800 CFM 1575-1800 CFM 1575-1800 CFM MCA¹ @ 575V MOP² (amps) @ 575V Actual kW & BTU @ 575V Recommended Airflow Range 8 21 27 31 15 25 30 35 10 15 18 1400-1800 CFM 1575-1800 CFM 1575-1800 CFM Model and Heat Kit Usage CPH048***4B*** EHK4-10 EHK4-15 EHK4-18 Model and Heat Kit Usage CPH048***7B*** EHK7-10 EHK7-15 EHK7-18 ¹ Minimum Circuit Ampacity ² Maximum Overcurrent Protection device KW CORRECTION FACTORS kW Correction Factor for 1- & 3-Phase Units Supply Voltage 240 230 220 210 Correction Factor 1 0.93 0.82 0.78 kW Correction Factor for 480V Units Actual Voltage 460 440 Correction Factor 0.92 0.84 430 0.8 For other voltage use voltage² / 480² kW Correction Factor for 575V Units Supply Voltage 560 550 Correction Factor 0.95 0.91 208 0.76 MINIMUM AIRFLOW FOR ELECTRIC HEAT Heater Size 10 kW 15 kW 18 kW Minimum CFM 1,400 1,575 1,575 540 0.88 Multiply rated kW by correction factor to get actual kW. SS-CPH36-60 www.goodmanmfg.com 13 PRODUCT SPECIFICATIONS HEAT KIT ELECTRICAL DATA (BLOWER ONLY, HEAT MODE) — 5 TONS Model and Heat Kit Usage CPH060***1D*** EHK1-10 EHK1-15 EHK1-20 MCA¹ @ 208 / 240V 42 82 / 94 104 / 120 127 / 146 MOP² (amps) @ 208 / 240V 60 90 / 110 110 / 125 150 / 150 Actual kW & BTU @ 240V Recommended Airflow Range Speed Tap 10 15 20 1750-2250 CFM 1750-2250 CFM 1850-2250 CFM T3, T4, T5 T3, T4, T5 T5 CPH060***3D*** EHK3-10 EHK3-15 EHK3-20 EHK3-25 29 51 / 59 64 / 74 77 / 89 90 / 104 45 60 / 60 70 / 80 80 / 90 100 / 110 10 15 20 25 1750-2250 CFM 1750-2250 CFM 1850-2250 CFM T3, T4, T5 T3, T4, T5 T5 CPH060***3B*** EHK3-10 EHK3-15 EHK3-20 EHK3-25 25 48 / 55 61 / 70 74 / 85 87 / 100 40 50 / 60 70 / 80 80 / 90 90 / 110 10 15 20 25 1750-2250 CFM 1750-2250 CFM 1850-2250 CFM T3, T4, T5 T3, T4, T5 T5 Model and Heat Kit Usage CPH060***4B*** EHK4-10 EHK4-15 EHK4-20 EHK4-25 MCA¹ @ 480V 12 27 35 43 50 MOP² (amps) @ 480V 20 30 40 45 60 Actual kW & BTU @ 480V Recommended Airflow Range 10 15 20 25 1750-2250 CFM 1750-2250 CFM 1850-2250 CFM --- Model and Heat Kit Usage CPH060***7B*** EHK7-10 EHK7-15 EHK7-20 EHK7-25 MCA¹ @ 575V 10 23 29 35 41 MOP² (amps) @ 575V 15 25 30 40 45 Actual kW & BTU @ 575V Recommended Airflow Range 10 15 20 25 1750-2250 CFM 1750-2250 CFM 1850-2250 CFM --- ¹ Minimum Circuit Ampacity ² Maximum Overcurrent Protection Device KW CORRECTION FACTORS kW Correction Factor for 1- & 3-Phase Units Supply Voltage 240 230 220 210 Correction Factor 1 0.93 0.82 0.78 208 0.76 kW Correction Factor for 480V Units Actual Voltage 460 440 430 Correction Factor 0.92 0.84 0.8 For other voltage use voltage² / 480² kW Correction Factor for 575V Units Supply Voltage 560 550 540 Correction Factor 0.95 0.91 0.88 MINIMUM AIRFLOW FOR ELECTRIC HEAT Heater Size Minimum CFM 10 kW 1,750 15 kW 1,750 20 kW 1,850 Multiply rated kW by correction factor to get actual kW 14 www.goodmanmfg.com SS-CPH36-60 SS-CPH36-60 www.goodmanmfg.com 1050 1200 1350 1050 1200 1350 67 15 104 30.7 31.9 34.9 MBh 15 118 273 12 129 288 16 117 270 12 127 285 15 122 310 12 134 328 16 121 307 12 132 324 18 15 129 353 12 140 373 16 127 350 12 139 369 15 135 398 11 147 420 16 133 394 12 146 416 14 139 439 11 152 464 15 138 435 11 151 459 21 219 102 ∆T Hi PR Lo PR 20 108 236 16 118 249 11 126 260 22 107 246 125 279 16 129 133 292 11 137 112 280 22 115 288 21 119 301 20 123 310 20 130 318 16 134 328 16 138 332 11 142 342 11 117 319 22 121 328 21 125 343 20 129 353 20 136 362 16 140 373 16 145 378 11 150 389 11 123 358 21 127 369 21 128 19 131 386 20 135 398 19 136 402 15 143 407 16 147 420 16 149 424 11 152 425 11 157 438 11 158 442 19 127 396 20 131 408 20 132 412 17 135 426 18 139 439 18 141 444 148 450 15 152 464 15 154 469 14 146 157 469 10 162 484 10 164 489 10 - High and low pressures are measured at the liquid and suction service ports. Design Superheat 7±2 °F, Design Subcooling 12 ±2 °F pressures measured @ the suction and liquid service ports, ARI 95 test conditions 114 265 20 118 301 11 151 20 373 134 - 0.78 0.69 0.53 0.34 0.81 0.72 0.55 0.35 0.83 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.88 0.79 0.60 0.39 0.89 0.80 0.60 0.39 111 288 16 142 11 393 126 11 445 31.3 32.2 34.8 37.4 30.5 31.4 34.0 36.5 29.8 30.7 33.2 35.6 29.1 29.9 32.4 34.8 27.6 28.4 30.8 33.0 25.6 26.3 28.5 30.6 130 273 19 130 15 377 - 422 S/T 122 254 21 122 19 357 141 392 MBh 112 268 11 144 20 332 129 - 15 - - - - - - - - - - - - 105 257 16 135 11 345 122 403 17 0.78 0.66 0.45 25.2 26.1 28.6 130 404 17 0.81 0.68 0.47 27.3 28.3 31.0 131 408 16 0.85 0.71 0.49 71 Lo PR 243 19 124 15 331 - 382 - 67 21 116 19 313 135 355 12 63 226 138 20 291 124 - 16 - - - - - - - - - - - 59 28.1 29.1 31.9 ∆T 130 11 304 116 358 19 0.78 0.65 0.45 27.2 28.2 30.8 125 366 18 0.81 0.67 0.47 29.4 30.5 33.4 127 369 17 0.85 0.71 0.49 - 71 Hi PR 119 15 291 - 339 - 67 0.81 0.72 0.55 0.35 0.84 0.75 0.57 0.36 0.86 0.77 0.58 0.37 0.88 0.79 0.60 0.38 0.92 0.82 0.62 0.40 0.93 0.83 0.63 0.40 112 19 276 128 315 12 63 S/T 131 20 256 118 - 16 - - - - - - - - - - - 59 30.3 31.4 34.4 106 123 10 271 111 315 19 0.75 0.63 0.43 28.6 29.6 32.5 120 325 18 0.78 0.65 0.45 31.0 32.1 35.2 121 328 18 0.82 0.68 0.47 - 71 33.9 34.9 37.7 40.5 33.1 34.1 36.9 39.6 32.3 33.2 36.0 38.6 31.5 32.4 35.1 37.7 29.9 30.8 33.3 35.8 27.7 28.5 30.9 33.2 113 15 259 - 298 - 67 MBh 246 124 277 12 63 Lo PR 20 228 ∆T Hi PR 113 - 16 - - - - - - - - - - - 59 31.9 33.1 36.2 0.84 0.76 0.57 0.37 0.88 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.93 0.83 0.63 0.40 0.96 0.86 0.65 0.42 0.97 0.87 0.66 0.42 106 277 19 0.73 0.61 0.42 29.3 30.4 33.3 114 285 18 0.75 0.63 0.44 31.7 32.9 36.1 115 288 18 0.79 0.66 0.46 - 71 34.9 35.9 38.9 41.7 34.1 35.1 38.0 40.7 33.3 34.2 37.1 39.8 32.4 33.4 36.2 38.8 30.8 31.7 34.4 36.9 28.6 29.4 31.8 34.2 - 262 - 67 S/T 117 243 12 63 MBh 107 - 16 - - - - - - - - - - - 59 32.7 33.9 37.1 101 247 19 0.71 0.59 0.41 30.0 31.1 34.1 110 251 18 0.73 0.61 0.43 32.5 33.7 36.9 111 254 18 0.77 0.64 0.45 - 71 Lo PR 233 - 67 115 18 12 63 105 217 16 59 33.5 34.7 38.0 95 Entering Indoor Wet Bulb Temperature 85 Outdoor Ambient Temperature ∆T - - - - - - - - - - - - 71 75 Hi PR 0.68 0.57 0.40 121 S/T 110 12 254 Lo PR 16 241 18 224 ∆T Hi PR 0.71 0.59 0.41 S/T 122 105 33.3 34.5 37.8 112 11 257 MBh 243 Lo PR 17 226 ∆T Hi PR 0.74 0.62 0.43 63 S/T 59 34.3 35.5 38.9 MBh Airflow IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions. 75 70 IDB 65 PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — 3 TONS 15 16 www.goodmanmfg.com 1050 1200 1350 1050 1200 1350 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 115 67 71 21 119 130 138 304 16 116 291 24 124 313 23 135 331 20 144 345 16 122 332 24 130 357 23 142 377 20 151 393 16 153 21 128 373 23 129 377 22 136 402 22 138 406 19 149 424 20 150 428 15 158 442 16 160 447 20 132 412 22 134 417 20 141 444 21 142 448 18 154 469 18 155 473 14 164 489 15 165 494 24 25 224 104 ∆T Hi PR Lo PR 25 110 241 24 121 254 20 128 265 26 110 251 127 285 24 131 136 297 21 140 114 285 26 117 294 25 121 307 25 125 317 25 132 324 24 136 334 23 141 338 21 145 349 20 120 325 26 123 335 25 127 350 25 131 361 25 139 369 24 143 381 24 148 385 21 153 397 20 125 366 25 129 377 24 131 22 133 393 25 138 406 24 139 410 22 146 416 24 150 428 23 152 433 19 155 433 20 160 447 20 162 451 20 130 404 23 134 417 22 135 421 21 138 435 23 142 448 22 144 453 151 459 22 155 473 22 157 478 21 149 160 479 19 165 494 19 167 499 18 159 High and low pressures are measured at the liquid and suction service ports. Design Superheat 7±2 °F, Design Subcooling 12 ±2 °F pressures measured @ the suction and liquid service ports, ARI 95 test conditions 117 270 25 120 307 20 154 22 381 137 15 474 0.89 0.86 0.78 0.63 0.93 0.89 0.81 0.65 0.95 0.92 0.83 0.67 0.98 0.95 0.85 0.69 1.00 0.98 0.89 0.72 1.00 0.99 0.89 0.72 113 294 23 145 20 401 128 19 455 32.4 33.0 34.6 36.9 31.6 32.2 33.8 36.0 30.9 31.5 32.9 35.1 30.1 30.7 32.1 34.3 28.6 29.2 30.5 32.6 26.5 27.0 28.3 30.2 132 278 25 133 23 385 154 21 430 S/T 124 259 25 125 23 364 144 22 400 MBh 114 273 20 147 23 338 132 16 429 107 262 23 138 19 352 124 20 411 Lo PR 248 24 126 23 338 147 23 390 25 119 24 320 138 24 362 231 141 23 297 126 16 381 ∆T 133 19 310 119 20 366 Hi PR 121 22 297 140 23 346 0.93 0.89 0.81 0.65 0.96 0.93 0.84 0.68 0.98 0.95 0.86 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.92 0.75 1.00 1.00 0.93 0.75 114 24 281 131 24 322 S/T 134 24 261 120 16 335 108 126 19 276 113 20 321 35.1 35.7 37.4 39.9 34.3 34.9 36.6 39.0 33.4 34.1 35.7 38.1 32.6 33.3 34.8 37.2 31.0 31.6 33.1 35.3 28.7 29.3 30.6 32.7 115 22 265 134 23 304 MBh 251 126 24 283 Lo PR 24 233 ∆T Hi PR 115 16 294 0.97 0.94 0.85 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.90 0.73 1.00 1.00 0.93 0.75 1.00 1.00 0.96 0.78 1.00 1.00 0.97 0.79 109 20 282 36.1 36.8 38.6 41.1 35.3 36.0 37.7 40.2 34.4 35.1 36.8 39.2 33.6 34.2 35.9 38.3 31.9 32.5 34.1 36.4 29.6 30.1 31.6 33.7 127 23 267 S/T 119 24 248 MBh 109 16 262 103 20 252 Lo PR 23 238 24 221 ∆T Hi PR 0.85 0.80 0.65 0.49 0.88 0.83 0.67 0.50 0.91 0.85 0.69 0.52 0.93 0.88 0.71 0.53 0.97 0.91 0.74 0.55 0.98 0.92 0.75 0.56 112 291 20 143 15 397 31.8 32.5 34.7 37.1 31.1 31.7 33.9 36.3 30.3 31.0 33.1 35.4 29.6 30.2 32.3 34.5 28.1 28.7 30.7 32.8 26.0 26.6 28.4 30.4 131 276 23 131 19 381 S/T 123 256 24 123 22 361 MBh 113 271 16 145 22 335 106 259 19 136 15 349 Lo PR 246 22 125 19 334 23 117 22 317 228 140 23 294 ∆T 131 15 307 Hi PR 120 19 294 0.88 0.83 0.67 0.50 0.92 0.86 0.70 0.52 0.94 0.88 0.72 0.54 0.97 0.91 0.74 0.55 1.00 0.94 0.77 0.57 1.00 0.95 0.77 0.58 113 22 278 S/T 132 23 259 107 124 15 273 34.5 35.2 37.6 40.2 33.7 34.4 36.8 39.3 32.9 33.6 35.9 38.4 32.1 32.8 35.0 37.4 30.5 31.1 33.3 35.5 28.2 28.8 30.8 32.9 114 19 262 MBh 248 Lo PR 22 231 ∆T Hi PR 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 1.00 0.92 0.75 0.56 1.00 0.95 0.78 0.58 1.00 1.00 0.81 0.60 1.00 1.00 0.81 0.61 63 105 S/T 59 95 Entering Indoor Wet Bulb Temperature 85 Outdoor Ambient Temperature 35.5 36.3 38.8 41.4 34.7 35.4 37.9 40.5 33.8 34.6 37.0 39.5 33.0 33.7 36.1 38.5 31.4 32.1 34.2 36.6 29.1 29.7 31.7 33.9 75 MBh Airflow IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects ARI Rating conditions. 85 80 IDB 65 PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — 3 TONS (CONT.) SS-CPH36-60 SS-CPH36-60 www.goodmanmfg.com 59 45.1 0.75 17 3.17 231 109 43.8 0.72 18 3.15 229 108 40.4 0.69 18 3.08 222 105 45.8 0.86 20 3.20 234 110 44.5 0.82 21 3.17 231 109 41.1 0.79 21 3.10 224 106 Airflow MBh S/T ∆T 1800 kW HI PR LO PR MBh S/T ∆T 1600 kW HI PR LO PR MBh S/T ∆T 1400 kW HI PR LO PR MBh S/T ∆T 1800 kW HI PR LO PR MBh S/T ∆T 1600 kW HI PR LO PR MBh S/T ∆T 1400 kW HI PR LO PR 47.2 0.77 18 3.26 251 117 45.8 0.73 19 3.23 249 116 42.3 0.70 20 3.16 242 113 63 46.7 0.63 15 3.23 249 116 45.4 0.60 16 3.21 246 115 41.9 0.58 16 3.14 239 112 51.1 0.58 15 3.35 266 128 49.6 0.55 16 3.33 263 127 45.8 0.53 16 3.25 255 123 67 51.2 0.44 11 3.33 263 127 49.7 0.42 12 3.30 260 126 45.9 0.40 12 3.23 252 122 54.8 0.37 10 3.45 277 136 53.2 0.36 11 3.42 274 135 49.1 0.34 11 3.35 266 131 71 44.8 0.89 20 3.42 262 117 43.5 0.85 21 3.39 260 115 40.1 0.82 22 3.32 252 112 59 44.0 0.78 18 3.39 260 115 42.7 0.74 18 3.37 257 114 39.5 0.72 19 3.29 249 111 46.1 0.79 19 3.49 282 124 44.8 0.76 19 3.46 279 123 41.3 0.73 20 3.38 271 119 63 45.6 0.65 15 3.46 279 123 44.3 0.62 16 3.43 277 122 40.9 0.60 16 3.36 268 118 49.9 0.60 15 3.59 298 135 48.4 0.57 16 3.56 295 134 44.7 0.55 16 3.48 286 130 67 50.0 0.45 12 3.56 295 134 48.5 0.43 12 3.53 292 133 44.8 0.42 12 3.46 283 129 75 53.6 0.39 11 3.70 311 144 52.0 0.37 11 3.67 308 143 48.0 0.36 11 3.58 298 138 71 43.7 0.91 20 3.61 298 121 42.4 0.87 21 3.59 295 120 39.2 0.84 22 3.51 286 116 45.0 0.81 19 3.69 321 129 43.7 0.78 19 3.66 318 128 40.3 0.75 20 3.58 308 124 48.7 0.62 15 3.80 339 141 47.3 0.59 16 3.77 336 139 43.7 0.57 16 3.68 325 135 52.3 0.40 11 3.91 353 150 50.8 0.38 11 3.88 350 148 46.8 0.36 11 3.79 339 144 42.6 0.94 20 3.79 340 127 41.4 0.90 21 3.76 336 126 38.2 0.86 22 3.67 326 122 43.9 0.84 19 3.87 366 135 42.6 0.80 20 3.84 362 134 39.3 0.77 20 3.75 351 130 47.5 0.64 15 3.98 386 148 46.1 0.61 16 3.95 382 146 42.6 0.58 16 3.86 371 142 71 - 51.0 0.41 11 4.11 403 157 49.5 0.39 11 4.07 399 156 45.7 0.38 11 3.98 387 151 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 43.0 44.5 48.8 41.9 43.5 47.6 0.80 0.67 0.46 0.83 0.69 0.48 18 15 12 18 15 12 3.59 3.66 3.77 3.76 3.84 3.95 295 318 335 336 362 382 120 128 139 126 134 146 41.7 43.2 47.4 40.7 42.2 46.2 0.76 0.64 0.44 0.79 0.66 0.46 18 16 12 18 16 12 3.56 3.63 3.74 3.73 3.81 3.92 292 315 332 333 358 378 119 126 138 125 133 145 38.5 39.9 43.7 37.6 38.9 42.7 0.74 0.61 0.43 0.76 0.63 0.44 19 16 12 19 16 12 3.48 3.55 3.65 3.65 3.72 3.83 284 305 322 323 347 367 115 123 134 121 129 140 40.5 0.97 20 3.94 382 133 39.3 0.93 21 3.91 378 132 36.3 0.90 21 3.82 367 128 59 39.8 0.86 17 3.91 378 132 38.7 0.82 18 3.88 374 131 35.7 0.79 18 3.79 363 127 41.7 0.87 19 4.02 411 142 40.5 0.83 19 3.99 407 140 37.4 0.80 20 3.89 395 136 63 41.3 0.72 15 3.99 407 140 40.1 0.68 16 3.95 403 139 37.0 0.66 16 3.86 391 135 45.1 0.66 15 4.14 434 155 43.8 0.63 16 4.11 430 153 40.5 0.61 16 4.01 417 149 67 45.2 0.50 11 4.11 430 153 43.9 0.47 12 4.08 426 152 40.5 0.46 12 3.98 413 147 105 48.5 0.42 11 4.27 453 165 47.0 0.40 11 4.24 448 163 43.4 0.39 11 4.14 435 158 71 37.5 0.98 19 4.06 422 138 36.4 0.94 20 4.03 418 137 33.6 0.90 20 3.94 405 132 59 36.9 0.86 16 4.03 418 137 35.8 0.82 17 4.00 414 135 33.1 0.80 17 3.91 401 131 38.6 0.88 17 4.15 454 147 37.5 0.84 18 4.12 450 145 34.6 0.81 18 4.02 436 141 63 38.2 0.72 14 4.11 450 145 37.1 0.69 15 4.08 445 144 34.3 0.66 15 3.99 432 140 41.8 0.67 14 4.28 480 160 40.6 0.63 15 4.24 475 159 37.5 0.61 15 4.14 461 154 67 41.9 0.50 11 4.24 475 159 40.7 0.48 11 4.21 470 157 37.5 0.46 11 4.11 456 152 115 44.9 0.43 10 4.41 500 171 43.6 0.41 10 4.38 495 169 40.2 0.39 10 4.27 481 164 71 - IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. Design Superheat 7±2 °F & Design Subcooling 12 ±2 °F pressures measured @ the suction and liquid access fittings; ARI 95° test conditions 75 70 IDB 65 PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — 4 TONS 17 18 www.goodmanmfg.com 59 46.7 0.94 22 3.22 236 111 45.3 0.90 23 3.20 234 110 41.8 0.86 24 3.13 227 107 47.5 0.98 24 3.24 238 113 46.1 0.94 25 3.22 236 111 42.5 0.91 25 3.15 229 108 Airflow MBh S/T ∆T 1800 kW HI PR LO PR MBh S/T ∆T 1600 kW HI PR LO PR MBh S/T ∆T 1400 kW HI PR LO PR MBh S/T ∆T 1800 kW HI PR LO PR MBh S/T ∆T 1600 kW HI PR LO PR MBh S/T ∆T 1400 kW HI PR LO PR 48.4 0.95 23 3.30 257 120 47.0 0.91 24 3.28 254 119 43.4 0.87 25 3.21 246 115 63 47.7 0.88 21 3.28 254 119 46.3 0.84 22 3.26 251 117 42.7 0.81 23 3.19 244 114 50.7 0.86 22 3.40 271 131 49.2 0.82 23 3.38 268 129 45.4 0.79 24 3.30 260 126 67 50.9 0.72 19 3.38 268 129 49.5 0.68 19 3.35 266 128 45.6 0.66 20 3.28 258 124 54.1 0.70 19 3.50 283 139 52.5 0.66 20 3.47 280 138 48.5 0.64 20 3.40 271 134 71 54.4 0.54 15 3.47 280 138 52.9 0.51 16 3.45 277 136 48.8 0.49 16 3.37 269 132 46.4 1.00 24 3.47 268 119 45.0 0.97 25 3.44 265 118 41.5 0.94 26 3.37 257 114 59 45.6 1.00 23 3.44 265 118 44.2 0.93 24 3.42 262 117 40.8 0.90 24 3.34 254 113 47.3 0.98 24 3.54 288 127 45.9 0.94 25 3.51 285 125 42.4 0.91 25 3.43 276 121 63 46.6 0.91 22 3.51 285 125 45.2 0.87 23 3.49 282 124 41.7 0.84 23 3.41 274 120 49.5 0.89 22 3.64 304 138 48.1 0.85 23 3.62 301 137 44.4 0.82 24 3.53 292 133 67 49.7 0.74 19 3.62 301 137 48.3 0.71 20 3.59 298 135 44.6 0.68 20 3.51 289 131 75 52.8 0.72 19 3.75 317 147 51.3 0.69 20 3.72 314 146 47.3 0.66 21 3.64 304 141 71 53.2 0.56 15 3.72 314 146 51.6 0.53 16 3.70 311 144 47.7 0.51 16 3.61 301 140 45.3 1.00 23 3.67 304 124 43.9 1.00 25 3.64 301 122 40.6 0.96 26 3.56 292 119 46.1 1.00 24 3.74 327 131 44.8 0.96 25 3.72 324 130 41.3 0.93 25 3.63 314 126 48.3 0.91 22 3.86 346 144 46.9 0.87 23 3.83 342 142 43.3 0.84 24 3.74 332 138 51.6 0.74 19 3.97 361 153 50.1 0.71 20 3.94 357 151 46.2 0.68 21 3.85 346 147 44.2 1.00 23 3.85 347 130 42.9 1.00 25 3.82 343 129 39.6 0.99 26 3.73 333 125 45.0 1.00 23 3.93 373 138 43.7 0.99 25 3.90 369 137 40.3 0.96 25 3.81 358 133 47.1 0.94 23 4.05 394 151 45.8 0.90 24 4.01 390 149 42.2 0.86 24 3.92 378 145 50.3 0.76 20 4.17 411 161 48.8 0.73 20 4.14 407 159 45.1 0.70 21 4.04 394 154 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 44.5 45.5 48.6 51.9 43.4 44.3 47.4 50.6 1.00 0.94 0.76 0.57 1.00 0.97 0.79 0.59 23 22 19 15 22 22 19 15 3.64 3.72 3.83 3.94 3.82 3.90 4.01 4.14 301 324 342 357 343 369 390 407 122 130 142 151 129 137 149 159 43.2 44.1 47.2 50.4 42.1 43.1 46.0 49.2 0.95 0.89 0.73 0.54 0.98 0.92 0.75 0.56 24 23 20 16 24 23 20 16 3.62 3.69 3.80 3.91 3.79 3.87 3.98 4.11 298 321 339 353 340 366 386 403 121 129 141 150 127 135 148 157 39.9 40.7 43.5 46.5 38.9 39.7 42.5 45.4 0.92 0.86 0.70 0.52 0.95 0.89 0.72 0.54 24 23 20 16 24 23 20 16 3.53 3.60 3.71 3.82 3.70 3.78 3.89 4.01 289 311 329 343 329 355 374 391 118 125 136 145 123 131 143 153 42.0 1.00 21 4.00 390 136 40.7 1.00 23 3.97 386 135 37.6 1.00 25 3.87 374 131 59 41.2 1.00 21 3.97 386 135 40.0 1.00 23 3.94 382 133 36.9 0.98 24 3.84 371 129 42.8 1.00 22 4.08 420 145 41.5 1.00 24 4.05 415 143 38.3 0.99 25 3.95 403 139 63 42.1 1.00 22 4.05 415 143 40.9 0.96 22 4.02 411 142 37.8 0.92 23 3.92 399 138 44.8 0.98 22 4.21 443 158 43.5 0.93 23 4.17 439 156 40.1 0.90 24 4.07 425 152 67 45.0 0.82 19 4.17 439 156 43.7 0.78 20 4.14 434 155 40.3 0.75 20 4.04 421 150 105 47.8 0.79 19 4.34 462 168 46.4 0.76 20 4.30 457 167 42.8 0.73 20 4.20 444 162 71 48.1 0.61 15 4.30 457 167 46.7 0.58 16 4.27 453 165 43.1 0.56 16 4.17 439 160 38.9 1.00 20 4.13 431 141 37.7 1.00 22 4.09 426 139 34.8 1.00 23 4.00 414 135 59 38.2 1.00 20 4.09 426 139 37.1 1.00 21 4.06 422 138 34.2 0.99 22 3.97 410 134 39.6 1.00 20 4.21 464 150 38.5 1.00 22 4.18 459 148 35.5 1.00 23 4.08 445 144 63 39.0 1.00 20 4.18 459 148 37.9 0.96 21 4.15 454 147 35.0 0.93 21 4.05 441 142 41.5 0.98 21 4.34 489 163 40.3 0.94 22 4.31 485 162 37.2 0.91 22 4.21 470 157 67 41.7 0.82 18 4.31 485 162 40.5 0.78 18 4.28 480 160 37.4 0.76 19 4.17 465 155 115 44.3 0.80 18 4.48 510 174 43.0 0.76 19 4.45 505 172 39.7 0.73 19 4.34 490 167 71 44.6 0.62 14 4.45 505 172 43.3 0.59 15 4.41 500 171 39.9 0.57 15 4.31 485 166 IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects ARI Rating conditions High and low pressures are measured at the liquid and suction access fittings. Design Superheat 7±2 °F & Design Subcooling 12 ±2 °F pressures measured @ the suction and liquid access fittings; ARI 95° test conditions 85 80 IDB 65 PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — 4 TONS (CONT.) SS-CPH36-60 SS-CPH36-60 www.goodmanmfg.com 59 58.4 0.75 17 4.00 10.5 244 105 56.7 0.71 18 3.97 10.4 242 104 52.3 0.69 18 3.87 10.2 234 101 59.4 0.85 20 4.03 10.6 246 106 57.7 0.81 21 4.00 10.5 244 105 53.2 0.78 21 3.90 10.3 237 102 Airflow MBh S/T ∆T 2306 kW Amps Hi Pr Lo Pr MBh S/T ∆T 2050 kW Amps Hi Pr Lo Pr MBh S/T ∆T 1794 kW Amps Hi Pr Lo Pr MBh S/T ∆T 2306 kW Amps Hi Pr Lo Pr MBh S/T ∆T 2050 kW Amps Hi Pr Lo Pr MBh S/T ∆T 1794 kW Amps Hi Pr Lo Pr 61.2 0.76 19 4.11 10.9 265 113 59.4 0.73 19 4.08 10.8 263 112 54.8 0.70 20 3.99 10.5 255 109 63 60.5 0.62 15 4.08 10.8 263 112 58.8 0.60 16 4.05 10.7 260 111 54.2 0.57 16 3.95 10.4 252 108 66.2 0.58 15 4.24 11.2 280 124 64.3 0.55 16 4.21 11.1 277 122 59.3 0.53 16 4.11 10.8 269 119 67 66.3 0.43 11 4.21 11.1 277 122 64.4 0.41 12 4.18 11.0 275 121 59.4 0.40 12 4.08 10.7 266 118 71.0 0.37 10 4.38 11.6 292 132 69.0 0.35 11 bb 11.5 289 130 63.7 0.34 11 4.24 11.2 281 126 71 58.0 0.88 20 4.34 11.5 277 112 56.3 0.84 21 4.30 11.4 274 111 52.0 0.81 22 4.20 11.1 266 108 59 57.0 0.78 18 4.30 11.4 274 111 55.4 0.74 18 4.27 11.3 271 110 51.1 0.71 19 4.17 11.0 263 107 59.7 0.79 19 4.43 11.7 298 120 58.0 0.75 20 4.40 11.6 295 118 53.5 0.72 20 4.29 11.3 286 115 63 59.1 0.65 15 4.39 11.6 295 118 57.4 0.62 16 4.36 11.5 292 117 53.0 0.60 16 4.25 11.2 283 114 64.7 0.60 15 4.57 12.1 314 131 62.8 0.57 16 4.54 12.0 311 129 57.9 0.55 16 4.43 11.7 302 125 67 64.8 0.45 12 4.53 12.0 311 129 62.9 0.43 12 4.50 11.9 308 128 58.1 0.41 12 4.39 11.6 299 124 75 69.4 0.38 11 4.72 12.5 328 139 67.4 0.37 11 4.68 12.4 325 138 62.2 0.35 11 4.57 12.1 315 134 71 56.6 0.90 20 4.61 12.4 315 117 55.0 0.86 21 4.57 12.3 311 116 50.7 0.83 22 4.46 12.0 302 112 58.3 0.81 19 4.71 12.7 338 124 56.6 0.77 20 4.67 12.6 335 123 52.2 0.74 20 4.56 12.3 325 119 63.1 0.61 15 4.86 13.1 357 136 61.3 0.58 16 4.82 13.0 354 134 56.6 0.56 16 4.70 12.7 343 130 67.7 0.39 11 5.02 13.6 373 145 65.8 0.38 11 4.98 13.5 369 143 60.7 0.36 11 4.86 13.1 358 139 56.9 0.83 19 4.96 13.6 386 131 55.2 0.80 20 4.92 13.5 382 129 51.0 0.77 20 4.79 13.1 370 125 61.6 0.63 16 5.12 14.0 407 143 59.8 0.60 16 5.08 13.9 403 141 55.2 0.58 16 4.95 13.5 391 137 66.1 0.41 11 5.29 14.5 425 152 64.2 0.39 11 5.25 14.4 420 150 59.2 0.37 11 5.11 14.0 408 146 71 52.5 0.97 20 5.05 14.1 403 129 51.0 0.92 21 5.01 14.0 399 127 47.0 0.89 21 4.89 13.6 387 124 59 51.6 0.85 18 5.01 14.0 399 127 50.1 0.81 18 4.97 13.8 395 126 46.3 0.78 19 4.85 13.5 383 122 54.0 0.87 19 5.17 14.4 434 137 52.5 0.83 19 5.12 14.3 429 136 48.4 0.80 20 5.00 13.9 417 131 63 53.5 0.71 15 5.12 14.3 429 135 51.9 0.68 16 5.08 14.2 425 134 47.9 0.65 16 4.95 13.8 412 130 58.5 0.66 15 5.34 14.9 458 149 56.8 0.63 16 5.29 14.8 453 148 52.4 0.60 16 5.16 14.4 440 144 67 58.6 0.49 12 5.29 14.8 453 148 56.9 0.47 12 5.25 14.6 449 146 52.5 0.45 12 5.12 14.2 435 142 105 62.8 0.42 11 5.52 15.5 478 159 61.0 0.40 11 5.47 15.3 473 158 56.3 0.39 11 5.33 14.9 459 153 71 48.6 0.98 19 5.23 14.9 445 133 47.2 0.93 20 5.19 14.8 441 132 43.6 0.90 20 5.06 14.4 428 128 59 47.8 0.86 16 5.19 14.8 441 132 46.4 0.82 17 5.14 14.6 436 130 42.8 0.79 17 5.01 14.2 423 127 50.1 0.87 17 5.35 15.3 479 142 48.6 0.83 18 5.30 15.1 474 140 44.9 0.80 18 5.17 14.7 460 136 63 49.6 0.72 14 5.30 15.1 474 140 48.1 0.68 15 5.26 15.0 470 139 44.4 0.66 15 5.13 14.6 456 135 54.2 0.66 14 5.52 15.8 506 155 52.6 0.63 15 5.48 15.6 501 153 48.6 0.61 15 5.34 15.2 486 148 67 54.3 0.50 11 5.48 15.6 501 153 52.7 0.47 11 5.43 15.5 496 151 48.7 0.46 11 5.29 15.1 481 147 115 58.2 0.43 10 5.71 16.4 528 165 56.5 0.41 10 5.66 16.2 523 163 52.1 0.39 10 5.52 15.8 507 158 71 - Shaded area is ARI Rating Conditions Design Super Heat 9 ±3 °F @ Suction Service port, ARI 95 test conditions 55.2 0.93 21 4.85 13.3 358 123 53.6 0.89 21 4.81 13.1 355 122 49.5 0.86 22 4.69 12.8 344 118 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 55.7 57.7 63.2 54.3 56.3 61.7 0.80 0.66 0.46 0.82 0.69 0.47 18 15 12 18 15 12 4.57 4.67 4.82 4.81 4.92 5.08 12.3 12.6 13.0 13.1 13.5 13.9 311 335 354 355 382 403 116 123 134 122 129 141 54.1 56.0 61.4 52.7 54.7 59.9 0.76 0.63 0.44 0.78 0.65 0.45 18 16 12 19 16 12 4.54 4.63 4.78 4.77 4.88 5.03 12.2 12.5 12.9 13.0 13.3 13.8 308 332 350 351 378 399 115 122 133 120 128 140 49.9 51.7 56.7 48.7 50.5 55.3 0.73 0.61 0.42 0.75 0.63 0.44 19 16 12 19 16 12 4.42 4.52 4.66 4.65 4.75 4.91 11.9 12.2 12.6 12.7 13.0 13.4 299 322 340 341 367 387 111 118 129 117 124 136 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65 PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — 5 TONS 19 20 Airflow MBh S/T ∆T 2306 kW Amps Hi Pr Lo Pr MBh S/T ∆T 2050 kW Amps Hi Pr Lo Pr MBh S/T ∆T 1794 kW Amps Hi Pr Lo Pr 59 60.4 0.93 22 4.06 10.7 249 108 58.7 0.89 23 4.03 10.6 247 106 54.2 0.86 24 3.93 10.4 239 103 63 61.8 0.87 22 4.15 11.0 268 114 60.0 0.83 22 4.12 10.9 265 113 55.4 0.80 23 4.02 10.6 257 110 67 66.0 0.71 19 4.28 11.3 283 125 64.1 0.68 20 4.24 11.2 280 124 59.1 0.65 20 4.14 10.9 272 120 71 70.5 0.53 15 4.42 11.7 295 133 68.5 0.51 16 4.38 11.6 292 132 63.2 0.49 16 4.27 11.3 283 128 59 59.0 0.97 23 4.37 11.6 279 114 57.3 0.92 24 4.34 11.5 277 112 52.9 0.89 24 4.23 11.2 268 109 63 60.3 0.91 22 4.47 11.8 301 121 58.6 0.86 23 4.43 11.7 298 120 54.1 0.83 23 4.32 11.4 289 116 67 64.5 0.74 19 4.61 12.2 317 132 62.6 0.70 20 4.57 12.1 314 131 57.8 0.68 20 4.46 11.8 305 127 75 71 68.9 0.55 15 4.76 12.7 331 141 66.9 0.53 16 4.72 12.5 328 139 61.7 0.51 16 4.61 12.2 318 135 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 57.6 58.9 62.9 67.3 56.2 57.5 61.4 65.6 1.00 0.93 0.76 0.57 1.00 0.96 0.78 0.58 23 22 19 15 22 22 19 15 4.65 4.75 4.90 5.07 4.89 5.00 5.16 5.33 12.5 12.8 13.3 13.7 13.4 13.7 14.1 14.7 318 342 361 377 362 389 411 429 118 126 137 146 124 132 144 153 56.0 57.2 61.1 65.3 54.6 55.8 59.6 63.7 0.95 0.89 0.72 0.54 0.98 0.92 0.74 0.56 24 23 20 16 24 23 20 16 4.61 4.71 4.86 5.02 4.85 4.96 5.12 5.29 12.4 12.7 13.1 13.6 13.3 13.6 14.0 14.5 315 339 357 373 358 386 407 425 117 124 136 145 123 131 143 152 51.6 52.8 56.4 60.3 50.4 51.5 55.0 58.8 0.91 0.85 0.70 0.52 0.94 0.88 0.72 0.54 24 23 20 16 24 23 20 16 4.50 4.59 4.74 4.90 4.73 4.83 4.99 5.16 12.1 12.4 12.8 13.2 12.9 13.2 13.6 14.1 305 328 347 362 348 374 395 412 113 121 132 140 119 127 138 147 59 53.4 1.00 21 5.10 14.2 407 130 51.9 1.00 23 5.05 14.1 403 129 47.9 0.98 24 4.93 13.7 391 125 63 54.6 1.00 22 5.21 14.6 438 138 53.0 0.95 23 5.17 14.4 434 137 48.9 0.92 23 5.04 14.0 421 133 67 58.3 0.81 19 5.38 15.0 463 151 56.6 0.77 20 5.34 14.9 458 149 52.3 0.75 20 5.20 14.5 444 145 105 71 62.3 0.61 15 5.56 15.6 483 161 60.5 0.58 16 5.52 15.5 478 159 55.9 0.56 16 5.38 15.0 463 154 59 49.5 1.00 20 5.27 15.0 450 134 48.0 1.00 22 5.23 14.9 445 133 44.3 0.98 22 5.10 14.5 432 129 63 50.6 1.00 20 5.39 15.4 484 143 49.1 0.96 21 5.35 15.3 479 142 45.3 0.92 21 5.21 14.9 465 137 67 54.0 0.82 18 5.57 15.9 511 156 52.4 0.78 18 5.53 15.8 506 155 48.4 0.75 19 5.38 15.3 491 150 115 71 57.7 0.61 14 5.76 16.5 533 166 56.1 0.58 15 5.71 16.4 528 165 51.7 0.56 15 5.57 15.9 512 160 MBh 61.5 62.7 65.7 70.1 60.1 61.2 64.1 68.4 58.6 59.8 62.6 66.8 57.2 58.3 61.1 65.2 54.4 55.4 58.0 61.9 50.3 51.3 53.8 57.3 S/T 0.98 0.94 0.85 0.69 1.00 0.98 0.88 0.72 1.00 1.00 0.90 0.73 1.00 1.00 0.93 0.76 1.00 1.00 0.97 0.79 1.00 1.00 0.98 0.79 ∆T 24 24 22 19 24 24 23 20 23 24 23 20 23 23 23 20 22 22 22 19 20 20 21 18 4.09 4.18 4.31 4.45 4.41 4.50 4.65 4.80 4.69 4.79 4.94 5.11 4.93 5.04 5.21 5.38 5.14 5.25 5.43 5.61 5.32 5.44 5.62 5.81 2306 kW Amps 10.8 11.1 11.4 11.8 11.7 11.9 12.3 12.8 12.7 13.0 13.4 13.9 13.5 13.8 14.3 14.8 14.3 14.7 15.2 15.7 15.2 15.6 16.1 16.7 Hi Pr 251 271 286 298 282 304 321 334 321 345 365 380 365 393 415 433 411 442 467 487 454 489 516 538 Lo Pr 109 116 126 134 115 122 133 142 119 127 138 147 125 133 145 155 131 140 152 162 136 144 158 168 MBh 59.7 60.9 63.7 68.0 58.3 59.5 62.3 66.4 56.9 58.0 60.8 64.8 55.5 56.6 59.3 63.3 52.8 53.8 56.3 60.1 48.9 49.8 52.2 55.7 S/T 0.93 0.90 0.81 0.66 0.97 0.93 0.84 0.68 0.99 0.96 0.86 0.70 1.00 0.99 0.89 0.72 1.00 1.00 0.92 0.75 1.00 1.00 0.93 0.76 ∆T 25 25 23 20 25 25 24 20 25 25 24 20 25 25 24 21 24 24 23 20 22 22 22 19 4.06 4.15 4.28 4.42 4.37 4.47 4.61 4.76 4.65 4.75 4.90 5.07 4.89 5.00 5.16 5.33 5.10 5.21 5.38 5.56 5.27 5.39 5.57 5.76 85 2050 kW Amps 10.7 11.0 11.3 11.7 11.6 11.8 12.2 12.7 12.5 12.8 13.3 13.7 13.4 13.7 14.1 14.7 14.2 14.6 15.0 15.6 15.0 15.4 15.9 16.5 Hi Pr 249 268 283 295 279 301 317 331 318 342 361 377 362 389 411 429 407 438 463 483 450 484 511 533 Lo Pr 108 114 125 133 114 121 132 141 118 126 137 146 124 132 144 153 130 138 151 161 134 143 156 166 MBh 55.1 56.2 58.8 62.8 53.8 54.9 57.5 61.3 52.6 53.6 56.1 59.9 51.3 52.3 54.7 58.4 48.7 49.6 52.0 55.5 45.1 46.0 48.2 51.4 S/T 0.90 0.87 0.78 0.64 0.93 0.90 0.81 0.66 0.96 0.92 0.83 0.68 0.99 0.95 0.86 0.70 1.00 0.99 0.89 0.72 1.00 1.00 0.90 0.73 ∆T 25 25 24 20 26 25 24 21 26 25 24 21 26 25 24 21 25 25 24 21 23 23 22 19 3.97 4.05 4.18 4.31 4.27 4.36 4.50 4.64 4.53 4.63 4.78 4.94 4.77 4.87 5.03 5.20 4.97 5.08 5.25 5.42 5.14 5.26 5.43 5.61 1794 kW Amps 10.4 10.7 11.0 11.4 11.3 11.5 11.9 12.3 12.2 12.5 12.9 13.4 13.0 13.3 13.8 14.3 13.8 14.2 14.6 15.2 14.6 15.0 15.5 16.1 Hi Pr 242 260 274 286 271 292 308 321 308 332 350 365 351 378 399 416 395 425 449 468 436 470 496 517 Lo Pr 104 111 121 129 110 117 128 136 115 122 133 142 120 128 140 149 126 134 146 156 130 139 151 161 IDB: Entering Indoor Dry Bulb Temperature Shaded area is ARI Rating Conditions High and low pressures are measured at the liquid and suction service valves. Design Super Heat 9 ±3 °F @ Suction Service port, ARI 95 test conditions 80 IDB 65 PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — 5 TONS (CONT.) www.goodmanmfg.com SS-CPH36-60 PRODUCT SPECIFICATIONS DIMENSIONS Downflow Horizontal L K S V X Y I U R W T N O P Q M J H G E D C B A F Z Point A B C D E F G H I J K L M SS-CPH36-60 Dimension (“) 3½ 2⅝ 11 17 4¾ 41½ 3 12 75⅛ 25 36⅜ 40⅞ 7 1/16 www.goodmanmfg.com Point N O P Q R S T U V W X Y Z Dimension (“) 17 7⅜ 11 4⅞ 1¾ 25 4½ 7½ 12 4½ 82¼ 81¼ 47⅜ 21 PRODUCT SPECIFICATIONS UNIT CLEARANCES Maintain an adequate clearance around the unit for safety, service, maintenance, and proper unit operation. Leave a total clearance of 75” on the main control panel side of the unit for possible removal of fan shaft, coil, electric heat, and gas furnace. Leave a clearance of 48” on all other sides of the unit for possible compressor removal or service access, and to ensure proper ventilation and condenser airflow. Do not install the unit beneath any obstruction. Install the unit away from all building exhausts to inhibit ingestion of exhaust air into the unit’s fresh-air intake. ELECTRICAL ENTRANCE LOCATIONS 8½” High-Voltage Entrance 8⅝” Low-Voltage Entrance 2¾” 22 www.goodmanmfg.com SS-CPH36-60 PRODUCT SPECIFICATIONS ROOF CURB INSTALLATION — RIGGING Provisions for forks have been included in the unit base frame. No other fork locations are approved. • Unit must be lifted by the four lifting holes located at the base frame corners. • Lifting cables should be attached to the unit with shackles. • The distance between the crane hook and the top of the unit must not be less than 60”. • Two spreader bars must span over the unit to prevent damage to the cabinet by the lift cables. Spreader bars must be of sufficient length so that cables do not come in contact with the unit during transport. Remove wood struts mounted beneath unit base frame before setting unit on roof curb. These struts are intended to protect unit base frame from fork lift damage. To remove the struts, extract the sheet metal retainers and pull the struts through the base of the unit. Refer to rigging label on the unit. Important: If using bottom discharge with roof curb, duct-work should be attached to the curb prior to installing the unit. Duct-work dimensions are shown in Roof Curb Installation Instructions Manual. Refer to the Roof Curb Installation Instructions for proper curb installation. Curbing must be installed in compliance with the National Roofing Contractors Association Manual. Compressor 23½” Return Lower unit carefully onto roof mounting curb. While rigging the unit, the center of Evaporator Coil gravity will cause the condenser end to be lower than the supply air end. Condenser Supply Bring condenser end of unit into alignment Coil with the curb. With condenser end of the unit resting on curb member and using curb as a fulcrum, lower opposite end of the unit until entire unit is seated on the curb. When a rectangular cantilever curb is 37” used, take care to center the unit. Check for proper alignment and orientation of supply Corner & Center-of-Gravity Locations and return openings with duct. Unit Weights To assist in determining rigging requirements, unit weights are shown to the right. Note: These weights are calculated without accessories installed. SS-CPH36-60 3-Ton Weights (lbs) 4-Ton Weights (lbs) 5-Ton Weights (lbs) Weight A 165 170 172 Weight B 160 164 163 Weight C 125 128 130 Weight D 120 123 123 Shipping Weight 590 605 610 Operating Weight 570 585 590 www.goodmanmfg.com 23 PRODUCT SPECIFICATIONS ROOF CURB INSTALLATION (CONT.) Curb installations must comply with local codes and should follow the established guidelines of the National Roofing Contractors Association. Proper unit installation requires that the roof curb be firmly and permanently attached to the roof structure. Check for adequate fastening method prior to setting the unit on the curb. Full perimeter roof curbs are available from the factory and are shipped unassembled. The installing contractor is responsible for field assembly, squaring, leveling, and mounting on the roof structure. All required hardware necessary for the assembly of the sheet metal curb is included in the curb accessory package. • Determine sufficient structural support before locating and mounting the curb and package unit. • Duct-work must be constructed using industry guidelines. The duct-work must be placed into the roof curb before mounting the package unit. Our full perimeter curbs include duct connection frames to be assembled with the curb. Cantilevered-type curbs are not available from the factory. • Contractor furnishes curb insulation, cant strips, flashing, and general roofing material. • Support curbs on parallel sides with roof members. To prevent damage to the unit, the roof 40¼ members cannot penetrate supply and return duct openings. Note: The unit and curb accessories are designed to allow vertical duct installation before unit 14 placement. Duct installation after unit placement is not recommended. 1/ ¾ See the manual shipped with the roof curb for 14 assembly and installation instructions. 3-D VIEW 74 19½ x 13⅜ Supply Opening 28⅞ x 12½ Return Opening 5 6 1⅜ TOP VIEW 74 40¼ 37 ID POWER AND LOW-VOLTAGE BLOCK LOCATIONS Single-Point Power Terminal Block 70¾ ID Low-Voltage Terminal Block (TB1) 24 www.goodmanmfg.com SS-CPH36-60 PRODUCT SPECIFICATIONS HAIL GUARD DIMENSIONS SS-CPH36-60 www.goodmanmfg.com 25 PRODUCT SPECIFICATIONS WIRING DIAGRAM — CPH036/48**1D** (SINGLE-PHASE DIRECT DRIVE) PU BK BK RD RD RD GR 1 2 3 C 208 240 TR G EBTDR NO K1 R XFMR-R COM XFMR-C K1 C NC NOTE #2 SPEED M1 M2 UP BL BL RD S2 3 1 S1 TB1 BK YL/PK GND O OR O BK GR YL PU RD R RD H C WH F 3 6 9 2 5 8 1 4 7 PU GR WH DFT DF1 RCCF RD RD RD RD YL LVJB BR RD R 3 6 2 5 1 4 BL WH W2 HVDR YL OR PLF 2 YL Y DF2 BK SEE NOTE #2 L1 T1 YL BK 4 LVDR BK BK SMOKE/FIRE DETECTOR REPLACES JUMPER BR BK C C RD PU 2 2 0 8 2 4 0 / 1 / 6 0 RD L2 BK RD BK DC PB T2 PK BL BL RD BL RD RD BL BL BK BL BL 24V RD YL PLF 1 PU BR WH BR OR OR BL BL BL TB1 BL T H E R M O S T A T Y1 Y/Y2 R G W1 W2 O C PU YL RD GR SA (IF USED) SEE NOTE 4 BK RD RD PU FC 3 SPEED BK BK BR EM RD BL RD PU BR BK RD EM PU BR 3 SPEED BK RD BK FC PU BL/PK CONTROL BOX T3 T2 T1 ALTERNATE MOTOR 6-WIRES SEE NOTE 7 BL DFT YL/PK YL CM HPS COMP LPS RVC L1 L2 SUPPLY VOLTAGE 208-240/1/60 C T2 C R T1 C COMP S C H DF1 DF2 HVDR RCCF F S.A. CM IF USED SA TB1 TR EM EBTDR BR 208-240V BLOWER INTERLOCK RELAY CONTACTOR CONDENSER MOTOR COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT ELECTRONIC BLOWER TIME DELAY ECONOMIZER EVAPORATOR MOTOR EQUPIMENT GROUND HIGH PRESSURE SWITCH HIGH VOLTAGE DEFROST RELAY LOW PRESSURE SWITCH LOW VOLTAGE DEFROST RELAY LOW VOLTAGE JUNCTION BOX POWER DISTRIBUTION BLOCK FEMALE PLUG / CONNECTOR REVERSING VALVE COIL RUN CAPACITOR FOR COMPRESSOR AND FAN START ASSIST TERMINAL BLOCK (24V SIGNAL) TRANSFORMER NOTES: SEE NOTE #3 3 1 TB1 TR 24V DFT R DFT W2 R DC Y LVDR C RVC O BR 7 4 8 5 9 6 C EBTDR R W2 O W1 Y Y2 LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRE CODE BK BLACK BL BLUE BR BROWN GR GREEN OR ORANGE PK PINK PU PURPLE RD RED WH WHITE YL YELLOW BL/PK BLUE WITH PINK STRIP YL/PK YELLOW WITH PINK STRIP THERMOSTAT FIELD WIRING NO ECONOMIZER W WH W G GR G R RD R YL Y2 Y1 Y/Y2 C BL O OR C O STAT TB1 WITH ECONOMIZER OPTION W G WH GR R RD Y1 W G R YL Y Y/Y2 C BL O OR C O STAT TB1 2 STAGE COOLING 6 5 4 3 2 1 R G XFMR 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE M1 OR M2 WIRE TO COM WHERE RD WIRE IS AND PLACE RD WIRE ON EMPTY M1 OR M2 TERMINAL. 3. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE AND RED WIRES FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER. 4. START ASSIST FACTOR EQUIPED WHEN REQUIRED 5. USE COPPER CONDUCTORS ONLY ++ USE N.E.C. CLASS 2 WIRE 6. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO ECONOMIZER ACCESSORY. 7. PURPLE WIRE CONNECTS TO TRANSFORMER (PIN 3) HPS PLF R C LPS FACTORY WIRING COMPONENT LEGEND BR C CM COMP DC DFT EBTR ECON EM GND HPS HVDR LPS LVDR LVJB PB PLF RVC RCCF Y1 THERMOSTAT G W PLF2 SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION C SEE NOTE #6 208-240/1/60 0140L00132 REV. B WH GR W G R RD Y1 YL R Y1 Y/Y2 PK Y2 C BL O OR G C 4 STAT TB1 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. WARNING 26 High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. www.goodmanmfg.com SS-CPH36-60 PRODUCT SPECIFICATIONS WIRING DIAGRAM — CPH036/48**3D** (THREE-PHASE DIRECT DRIVE) PU BK BK RD RD RD G BL GR 2 3 C 208 240 BK BL TR EBTDR R XFMR-R XFMR-C C BL COM K1 PK BL NC NOTE #2 M1 M2 RD RD BL S2 BK BK 3 1 BL TB1 YL T3 RD RD T2 RD L2 BK SEE NOTE #2 L1 T1 YL BK YL/PK GND YL OR BK BR C GR 3 6 2 5 1 4 YL Y O OR O BK PLF 2 YL PU LVDR RD LVJB RD R WH BK R HVDR RD C RCCF 3 F 6 GR PU 9 DFT DF1 DF2 YL BR WH W2 2 0 8 2 4 0 / 3 / 6 0 C BK BK SMOKE/FIRE DETECTOR REPLACES JUMPER PB OR L3 PU 2 4 DC RD S1 RD BL BL 24V RD NO K1 SPEED UP BL 1 RD RD RD 2 5 8 1 4 7 PLF 1 WH BR OR BL BL T H E R M O S T A T Y1 Y/Y2 R G W1 W2 O C PU YL RD GR WH BR OR BL BL TB1 PU BK RD RD BK RD BL PU PU BR EM BK FC 3 SPEED PU BR BK YL/PK BL/PK T3 T2 T1 EM BR CONTROL BOX RD YL RD DFT 3 SPEED ALTERNATE MOTOR 6-WIRES SEE NOTE 6 BL BK RD BK FC PU CM HPS COMP LPS RVC L1 LINE VOLTAGE LOW VOLTAGE C T2 C T1 COMP BR C CM COMP DC DFT ECON EM GND HPS HVDR LPS LVDR LVJB PB PLF RVC RCCF C T3 T3 C DF2 DF1 RCCF HVDR F CM EM EBTDR BR 208-240V SEE NOTE #3 3 TB1 TR 1 TB1 TR 24V DFT LVDR DC Y DFT W2 C RVC O BR 7 4 8 5 9 6 BLOWER INTERLOCK RELAY CONTACTOR CONDENSER MOTOR COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT ECONOMIZER EVAPORATOR MOTOR EQUPIMENT GROUND HIGH PRESSURE SWITCH HIGH VOLTAGE DEFROST RELAY LOW PRESSURE SWITCH LOW VOLTAGE DEFROST RELAY LOW VOLTAGE JUNCTION BOX POWER DISTRIBUTION BLOCK FEMALE PLUG / CONNECTOR REVERSING VALVE COIL RUN CAPACITOR FOR CONDENSER FAN TERMINAL BLOCK (24V SIGNAL) TRANSFORMER NOTES: R C LPS 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE M1 OR M2 COM WHERE RD WIRE IS AND PLACE RD WIRE ON EMPTY M1 OR M2 TERMINAL. 3. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE AND RED WIRES FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER. 4. USE COPPER CONDUCTORS ONLY ++ USE N.E.C. CLASS 2 WIRE 5. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO ECONOMIZER ACCESSORY. 6. PURPLE WIRE CONNECTS TO TRANSFORMER (PIN 3) 6 5 4 3 2 1 R C G XFMR W1 Y/ Y2 THERMOSTAT FIELD WIRING NO ECONOMIZER W W G WH GR R RD R YL Y2 Y/Y2 C BL O OR G C O STAT TB1 WITH ECONOMIZER OPTION W WH G GR R RD Y1 YL W G R Y Y/Y2 C BL O OR TB1 W PLF2 R O HIGH VOLTAGE LOW VOLTAGE WIRE CODE BK BLACK BL BLUE BR BROWN GR GREEN OR ORANGE PK PINK PU PURPLE RD RED WH WHITE YL YELLOW BL/PK BLUE WITH PINK STRIP YL/PK YELLOW WITH PINK STRIP C O STAT 2 STAGE COOLING HPS EBTDR W2 FIELD WIRING Y1 PLF R OPTIONAL HIGH VOLTAGE COMPONENT LEGEND T2 T1 R FACTORY WIRING L3 L2 SUPPLY VOLTAGE 208-240/3/60 Y1 THERMOSTAT O G C SEE NOTE #5 SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION 208-240/3/60 0140L00129 REV. B WH GR W G R RD Y1 YL R Y1 Y/Y2 PK Y2 C BL O OR TB1 G C 4 STAT Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. WARNING SS-CPH36-60 High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. www.goodmanmfg.com 27 PRODUCT SPECIFICATIONS WIRING DIAGRAM — CPH36/48/60**3B*** (THREE PHASE, BELT DRIVE) OR BK BK BK OR RD RD RD RD GR S1 PK S2 1 3 208 240 C G EBTDR R XFMR-R XFMR-C C BL 85**) :5 BL RD NO K1 GR COM K1 OR BL YL T3 RD RD T2 RD BL REPLACE JUMPER WITH SMOKE/FIRE DETECTOR BK BK RD L2 C BL BK SEE NOTE #2 L1 T1 YL YL/PK BL BL 2 0 8 2 4 0 / 3 / 6 0 PB OR L3 TR 24V TB1 PU NC M2 M1 BL GND YL DC OR C GR YL Y OR O BK LVDR GR BL PLF 2 O BR L2 T1 T2 RD R HVDR C RCCF F 3 6 9 2 5 8 PU YL RD GR WH BR OR BL 1 4 7 RD GR WH OR BL BL DFT DF1 DF2 RD BR RD BC RD PU RD WH PU RD BK T3 YL LVJB WH R L3 C BK YL BL RD W2 L1 PU 3 6 2 5 1 4 PLF 1 OR BL TB1 RD RD RD PU BK BR BK BK T H E R M O S T A T Y1 Y/Y2 R G W1 W2 O C CONTROL BOX YL/PK YL BL/PK T3 T1 T2 EM DFT BK CM COMP LPS HPS RVC L1 FACTORY WIRING L3 L2 SUPPLY VOLTAGE 208-240/3/60 T2 C BC C CM COMP DC DFT ECON EBTD EMR R EM FC GND HPS HVDR LPS LVDR LVJB PB PLF RVC RCCF C T2 T1 T1 COMP C T3 T3 C DF1 RCCF DF2 HVDR F CM BC 1 EM 3 BC TB1 TR BC 208-240V 1 TR 24V NOTES: R R HVDR EBTDR BC EBTDR DFT R W2 LVDR DC Y DFT C RVC OPTIONAL HIGH VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRE CODE BK BLACK BL BLUE BR BROWN GR GREEN OR ORANGE PK PINK PU PURPLE RD RED WH WHITE YL YELLOW BL/PK BLUE WITH PINK STRIP YL/PK YELLOW WITH PINK STRIP THERMOSTAT FIELD WIRING NO ECONOMIZER < , 7 > >> ( 4 < , 7 WH GR RD > ( 4 YL BL OR STAT TB1 C G R R BLOWER CONTACTOR CONTACTOR CONDENSER MOTOR COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT ECONOMIZER ELECTRONIC BLOWER TIME DELAY EVAPORATOR MOTOR RELAY RELAY EVAPORATOR MOTOR FAN CAPACITOR EQUPIMENT GROUND HIGH PRESSURE SWITCH HIGH VOLTAGE DEFROST RELAY LOW PRESSURE SWITCH LOW VOLTAGE DEFROST RELAY LOW VOLTAGE JUNCTION BOX POWER DISTRIBUTION BLOCK FEMALE PLUG / CONNECTOR REVERSING VAVLE COIL RUN CAPACITOR FOR CONDENSER FAN TERMINAL BLOCK (24V SIGNAL) TRANSFORMER 3 TB1 EBTDR LINE VOLTAGE LOW VOLTAGE COMPONENT LEGEND 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. USE COPPER CONDUCTORS ONLY ++ USE N.E.C. CLASS 2 WIRE 3. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY. O WITH ECONOMIZER OPTION < , 7 > >> ( 4 WH GR RD YL BL OR LPS O R W2 O W1 THERMOSTAT Y/ Y2 2 STAGE COOLING C HPS 6 5 4 PLF2 3 2 1 Y1 G SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION C SEE NOTE #3 ( 4 STAT TB1 P 4 L F 5 1 6 < , 7 > 208-240/3/60 0140L00064 REV. C < , 7 > >> ( 4 WH GR RD YL PK BL OR < , 7 > > ( 4 STAT TB1 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. WARNING 28 High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. www.goodmanmfg.com SS-CPH36-60 PRODUCT SPECIFICATIONS WIRING DIAGRAM — CPH36/48/60**4B (460V BELT DRIVE) OR BK RD RD 3 1 S2 S1 480 PK EBTDR R XFMR-R XFMR-C C BL 85**) :5 BL K1 NO K1 COM RD M1 YL T3 L3 RD RD T2 L2 OR BK BK BK SEE NOTE #2 L1 T1 YL YL/PK BL GND YL DC BL OR GR PLF 2 YL C YL Y O OR O BK LVDR GR R HVDR RD C RCCF F DF1 RD BL RD 6 9 5 8 PU YL RD GR WH BR OR BL 1 4 7 RD GR WH OR BL BR BC 1 RD RD 3 2 DFT T3 DF2 BK WH PU BK C T2 T1 YL BL LVJB RD R L3 3 6 2 5 1 4 WH W2 L2 PU BR RD BL L1 4 6 0 / 3 / 6 0 RD C BL REPLACE JUMPER WITH SMOKE/FIRE DETECTOR PU NC M2 PB BL C 24V TB1 GR BK RD BL TR G BL BL RD GR OR BK OR RD PU 3 CMR 2 OR PLF 1 BL T H E R M O S T A T Y1 Y/Y2 R G W1 W2 O C TB1 RD RD RD RD PU BK BR BK BK YL/PK BL/PK YL CONTROL BOX T3 T1 T2 EM DFT BK CM HPS COMP LPS RVC L1 T2 C T1 BC C CM CMR COMP DC DFT ECON EBTD EMR R EM FC GND HPS HVDR LPS LVDR LVJB PB PLF RVC RCCF C COMP C T3 T3 C DF1 RCCF DF2 HVDR F CM BC 1 EM 3 BC 460V BC 1 TB1 TR 3 TB1 24V NOTES: R CMR R HVDR EBTDR BC EBTDR DFT R W2 LVDR DC Y DFT C RVC OPTIONAL HIGH VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRE CODE BK BLACK BL BLUE BR BROWN GR GREEN OR ORANGE PK PINK PU PURPLE RD RED WH WHITE YL YELLOW BL/PK BLUE WITH PINK STRIP YL/PK YELLOW WITH PINK STRIP THERMOSTAT FIELD WIRING NO ECONOMIZER < , 7 > >> ( 4 WH GR RD YL BL OR 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. USE COPPER CONDUCTORS ONLY ++ USE N.E.C. CLASS 2 WIRE 3. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY. O LPS O < , 7 > >> ( 4 WH GR RD YL BL OR R W2 O W1 THERMOSTAT Y/ Y2 6 5 4 PLF2 3 2 1 Y1 SEE NOTE 5 G SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION C SEE NOTE #3 < , 7 > ( 4 STAT 2 STAGE COOLING C HPS > ( 4 WITH ECONOMIZER OPTION TB1 P 4 L F 5 1 6 < , 7 STAT TB1 C G R R BLOWER CONTACTOR CONTACTOR CONDENSER MOTOR CONDENSER MOTOR RELAY COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT ECONOMIZER ELECTRONIC BLOWER TIME DELAY EVAPORATOR MOTOR RELAY RELAY EVAPORATOR MOTOR FAN CAPACITOR EQUPIMENT GROUND HIGH PRESSURE SWITCH HIGH VOLTAGE DEFROST RELAY LOW PRESSURE SWITCH LOW VOLTAGE DEFROST RELAY LOW VOLTAGE JUNCTION BOX POWER DISTRIBUTION BLOCK FEMALE PLUG / CONNECTOR REVERSING VAVLE COIL RUN CAPACITOR FOR CONDENSER FAN TERMINAL BLOCK (24V SIGNAL) TRANSFORMER TR EBTDR LINE VOLTAGE LOW VOLTAGE COMPONENT LEGEND T2 T1 FACTORY WIRING L3 L2 SUPPLY VOLTAGE 460/3/60 460/3/60 0140L00017 REV. C < , 7 > >> ( 4 WH GR RD YL PK BL OR TB1 < , 7 > > ( 4 STAT Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. WARNING SS-CPH36-60 High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. www.goodmanmfg.com 29 PRODUCT SPECIFICATIONS WIRING DIAGRAM — CPH36/48/60***7B*** (575V, BELT DRIVE) OR BK BK OR OR RD RD RD BL 85**) :5 BL RD K1 NO K1 COM RD 24V TB1 GR C YL T3 L3 PB RD RD T2 L2 OR 5 7 5 / 3 / 6 0 TR BL BL REPLACE JUMPER WITH SMOKE/FIRE DETECTOR BK BK PU NC M2 M1 575 S1 PK S2 BK RD BL 3 1 GR G EBTDR R XFMR-R XFMR-C C BL BL RD C BK SEE NOTE #2 L1 T1 YL YL/PK GND C YL O LVDR GR PU BK C WH DF1 DF2 RD C RCCF F RD BL RD 1 RD RD 3 6 2 5 8 1 4 7 GR 9 PU 3 CMR 2 OR WH OR BR BC BK PU YL RD GR WH BR OR BL PLF 1 DFT T3 T2 BR RD BK RD R HVDR T1 LVJB WH R L3 YL BL RD W2 L2 L1 3 6 2 5 1 4 OR O BL BL YL GR YL Y DC PLF 2 OR BL BL T H E R M O S T A T Y1 Y/Y2 R G W1 W2 O C TB1 RD RD PU BK EM BR BK YL/PK BK YL T3 T1 T2 DFT BK CONTROL BOX BL/PK RD RD HPS CM COMP LPS RVC L1 T2 C T1 C T3 T3 DF1 RCCF DF2 HVDR F CM BC 1 EM 3 BC 575V BC 3 TB1 TR 1 TB1 TR 24V EBTDR NOTES: R CMR EBTDR R BC EBTDR DFT R W2 LVDR DC Y DFT C RVC OPTIONAL HIGH VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRE CODE BK BLACK BL BLUE BR BROWN GR GREEN OR ORANGE PK PINK PU PURPLE RD RED WH WHITE YL YELLOW BL/PK BLUE WITH PINK STRIP YL/PK YELLOW WITH PINK STRIP THERMOSTAT FIELD WIRING NO ECONOMIZER < , 7 > >> ( 4 WH GR RD YL BL OR 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. USE COPPER CONDUCTORS ONLY ++ USE N.E.C. CLASS 2 WIRE 3. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY. O LPS O < , 7 > >> ( 4 WH GR RD YL BL OR 6 5 4 PLF2 3 2 1 6 R W2 O W1 THERMOSTAT Y/ Y2 Y1 SEE NOTE 5 G SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION C SEE NOTE #3 < , 7 > ( 4 STAT 2 STAGE COOLING C HPS > ( 4 WITH ECONOMIZER OPTION TB1 P 4 L F 5 1 < , 7 STAT TB1 C G R R HVDR BLOWER CONTACTOR CONTACTOR CONDENSER MOTOR CONDENSER MOTOR RELAY COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT ECONOMIZER ELECTRONIC BLOWER TIME DELAY EVAPORATOR MOTOR RELAY RELAY EVAPORATOR MOTOR FAN CAPACITOR EQUPIMENT GROUND HIGH PRESSURE SWITCH HIGH VOLTAGE DEFROST RELAY LOW PRESSURE SWITCH LOW VOLTAGE DEFROST RELAY LOW VOLTAGE JUNCTION BOX POWER DISTRIBUTION BLOCK FEMALE PLUG / CONNECTOR REVERSING VAVLE COIL RUN CAPACITOR FOR CONDENSER FAN TERMINAL BLOCK (24V SIGNAL) TRANSFORMER BC C CM CMR COMP DC DFT ECON EBTD EMR R EM FC GND HPS HVDR LPS LVDR LVJB PB PLF RVC RCCF C COMP C LINE VOLTAGE LOW VOLTAGE COMPONENT LEGEND T2 T1 FACTORY WIRING L3 L2 SUPPLY VOLTAGE 575/3/60 575/3/60 0140L00067 REV. C < , 7 > >> ( 4 WH GR RD YL PK BL OR < , 7 > > ( 4 STAT TB1 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. WARNING 30 High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. www.goodmanmfg.com SS-CPH36-60 PRODUCT SPECIFICATIONS WIRING DIAGRAM — CPH060***1D*** (SINGLE-PHASE, DIRECT DRIVE) BK RD RD REPLACE JUMPER W ITH SMOKE/FIRE DETECTOR TB1 RD BL PB 2 3 C 208 TR 240 RD RD T2 RD L2 BK C BL BK BK BL BK SEE NOTE #2 L1 T1 YL YL YL/PK RD LVDR GR YL PU YL O OR O BK BR W2 WH R PLF 1 RD H C F 3 6 9 2 5 8 1 4 7 GR WH DFT GR WH DF1 DF2 RCCF RD RD 1 RD RD 5 OR BR YL YL TB1 WH BR WH BR OR OR BL BL BL TB1 SA (IF USED) SEE NOTE 4 WH PU RD RD RD 1 2 3 4 5 EM C L G N PU BK BR BK BK YL/PK YL BL/PK CONTROL BOX T3 T1 T2 DFT BK BL CM HPS ,7 '0 COMP 7) LPS RVC FACTORY WIRING L2 L1 C C CM COMP DC DFT ECON EM GND HPS HVDR LPS LVDR LVJB PB PLF RVC RCCF C T2 R T1 C COMP S C H DF1 DF2 HVDR RCCF F S.A. CM IF USED N SA TB1 TR L EM CONTACTOR CONDENSER MOTOR COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT ECONOMIZER EVAPORATOR MOTOR EQUPIMENT GROUND HIGH PRESSURE SWITCH HIGH VOLTAGE DEFROST RELAY LOW PRESSURE SWITCH LOW VOLTAGE DEFROST RELAY LOW VOLTAGE JUNCTION BOX POWER DISTRIBUTION BLOCK FEMALE PLUG / CONNECTOR REVERSING VALVE COIL RUN CAPACITOR FOR COMPRESSOR AND FAN START ASSIST TERMINAL BLOCK (24V SIGNAL) TRANSFORMER OPTIONAL HIGH VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRE CODE BK BLACK BL BLUE BR BROWN GR GREEN OR ORANGE PK PINK PU PURPLE RD RED WH WHITE YL YELLOW BL/PK BLUE WITH PINK STRIP YL/PK YELLOW WITH PINK STRIP THERMOSTAT FIELD WIRING NO ECONOMIZER G 208-240V NOTES: SEE NOTE #3 3 1 TB1 TR 24V DFT W2 R LINE VOLTAGE LOW VOLTAGE COMPONENT LEGEND SUPPLY VOLTAGE 208-240/1/60 R T H E R M O S T A T Y1 Y/Y2 R G W1 W2 O C PU YL RD GR BL PU YL LVJB BK RD R HVDR 3 6 2 5 1 4 BL WH RD YL YL OR PLF 2 C Y 6 0 GND BL DC 2 0 8 2 4 0 / 1 / BL 24V PK RD BL 1 S1 S2 BK DC Y DFT C RVC O LVDR 1 2 3 4 5 P 4 L F 5 1 6 SEE NOTE #2 EM C 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW LEADS FROM "3" AND "4" TO "4" AND "5". IF BOTH LEADS ARE ENERGIZED, THE HIGHER SPEED SETTING IS USED. 3. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRES FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER. 4. START ASSIST FACTOR EQUIPED WHEN REQUIRED 5. USE COPPER CONDUCTORS ONLY ++ USE N.E.C. CLASS 2 WIRE 6. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO ECONOMIZER ACCESSORY. C LPS < , 7 > >> ( 4 WH GR RD YL BL OR < , 7 > ( 4 STAT TB1 WITH ECONOMIZER OPTION < , 7 > >> ( 4 WH GR RD YL BL OR < , 7 > ( 4 STAT TB1 2 STAGE COOLING HPS 6 5 4 3 2 1 PLF2 R W2 O W1 Y Y2 Y1 THERMOSTAT G C SEE NOTE #6 SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION 208-240/1/60 0140L00016 REV. C < , 7 > >> ( 4 WH GR RD YL PK BL OR TB1 < , 7 > > ( 4 STAT Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. WARNING SS-CPH36-60 High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. www.goodmanmfg.com 31 PRODUCT SPECIFICATIONS WIRING DIAGRAM — CPH060***3D*** (3-PHASE, DIRECT DRIVE) RD BK RD REPLACE JUMPER WITH SMOKE/FIRE DETECTOR RD BK BK BL BL TB1 S2 1 2 3 C 208 TR 240 S1 24V PK RD PB YL T3 RD RD T2 BK BK OR L3 RD L2 C BL BL BK SEE NOTE #2 L1 T1 YL BL YL GND YL/PK YL OR RD DC C GR LVDR O OR O BK PLF 2 YL PU BR RD WH RD R PLF 1 BK WH R HVDR RD C RCCF F 3 6 9 2 5 8 1 4 7 GR WH DFT YL DF1 DF2 TB1 RD RD 1 RD 5 OR BR WH BR OR BL TB1 PU RD RD CONTROL BOX BK RD 1 2 3 4 5 EM C L G N PU BR BK BK YL/PK YL BL/PK T3 T1 T2 DFT BL BK CM HPS ,7 '0 COMP 7) LPS RVC L1 FACTORY WIRING L3 L2 LINE VOLTAGE LOW VOLTAGE SUPPLY VOLTAGE 208-240/3/60 OPTIONAL HIGH VOLTAGE COMPONENT LEGEND C CM COMP DC DFT ECON EM GND HPS HVDR LPS LVDR LVJB PB PLF RVC RCCF C T2 C T2 T1 T1 COMP C T3 T3 C DF2 DF1 RCCF HVDR F CM L EM N TB1 TR G CONTACTOR CONDENSER MOTOR COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT ECONOMIZER EVAPORATOR MOTOR EQUPIMENT GROUND HIGH PRESSURE SWITCH HIGH VOLTAGE DEFROST RELAY LOW PRESSURE SWITCH LOW VOLTAGE DEFROST RELAY LOW VOLTAGE JUNCTION BOX POWER DISTRIBUTION BLOCK FEMALE PLUG / CONNECTOR REVERSING VALVE COIL RUN CAPACITOR FOR CONDENSER FAN TERMINAL BLOCK (24V SIGNAL) TRANSFORMER 208-240V SEE NOTE #3 3 TR 24V DFT R W2 LVDR NOTES: 1 TB1 R T H E R M O S T A T Y1 Y/Y2 R G W1 W2 O C PU YL RD GR WH BR OR BL BL BL YL WH PU YL LVJB WH W2 GR 3 6 2 5 1 4 YL Y 2 0 8 2 4 0 / 3 / 6 0 BL DC Y DFT C RVC O 1 2 3 4 5 SEE NOTE #2 EM C C LPS 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW LEADS FROM "3" AND "4" TO "4" AND "5". IF BOTH LEADS ARE ENERGIZED, THE HIGHER SPEED SETTING IS USED. 3. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRES FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER. 4. USE COPPER CONDUCTORS ONLY ++ USE N.E.C. CLASS 2 WIRE 5. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO ECONOMIZER ACCESSORY. FIELD WIRING FIELD WIRING HIGH HIGH VOLTAGE VOLTAGE LOW VOLTAGE VOLTAGE LOW WIRE CODE WIRE CODE BK BLACK BL BLUEBK BLACK BR BROWN BL BLUE GR GREEN BR BROWN OR ORANGE GR GREEN PK PINKOR ORANGE PU PURPLE PK PINK RD RED PU PURPLE WH WHITE RD RED YL YELLOW WH WHITE BL/PK BLUE PINK STRIP YL WITH YELLOW YL/PK YELLOW WITH PINK STRIP THERMOSTAT FIELD WIRING NO ECONOMIZER < , 7 > >> ( 4 < , 7 WH GR RD > ( 4 YL BL OR STAT TB1 WITH ECONOMIZER OPTION < , 7 > >> ( 4 < , 7 > WH GR RD YL ( 4 BL OR STAT TB1 2 STAGE COOLING P 4 L F 5 1 6 HPS 6 5 4 3 2 1 PLF2 R W2 O W1 Y/ Y2 Y1 THERMOSTAT O G C SEE NOTE #5 SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION 208-240/3/60 0140L00012 REV. C < , 7 > >> ( 4 < , 7 > > ( 4 WH GR RD YL PK BL OR STAT TB1 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. WARNING 32 High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. www.goodmanmfg.com SS-CPH36-60 PRODUCT SPECIFICATIONS WIRING DIAGRAM — CPH60***3B*** (THREE PHASE, BELT DRIVE) OR BK BK BK OR RD RD RD RD GR S1 PK S2 1 3 208 240 C G EBTDR R XFMR-R XFMR-C C BL 85**) :5 BL RD NO K1 GR COM K1 OR BL YL T3 RD RD T2 RD BL REPLACE JUMPER WITH SMOKE/FIRE DETECTOR BK BK RD L2 C BL BK SEE NOTE #2 L1 T1 YL YL/PK BL BL 2 0 8 2 4 0 / 3 / 6 0 PB OR L3 TR 24V TB1 PU NC M2 M1 BL GND YL DC OR C GR YL Y O BR BK LVDR GR BL PLF 2 LVJB C RCCF F DF1 RD 6 PU YL RD GR WH BR OR BL 2 5 8 1 4 7 RD GR WH OR BL BL 9 BR RD BC RD PU RD 3 DFT T3 DF2 BK WH PU RD BK RD R C T2 YL BL WH R L3 HVDR T1 PU RD W2 L2 L1 YL OR O 3 6 2 5 1 4 PLF 1 OR BL TB1 RD RD RD PU BK BR BK BK T H E R M O S T A T Y1 Y/Y2 R G W1 W2 O C CONTROL BOX YL/PK YL BL/PK T3 T1 T2 EM DFT BK CM COMP LPS HPS RVC L1 FACTORY WIRING L3 L2 SUPPLY VOLTAGE 208-240/3/60 T2 C BC C CM COMP DC DFT ECON EBTD EMR R EM FC GND HPS HVDR LPS LVDR LVJB PB PLF RVC RCCF C T2 T1 T1 COMP C T3 T3 C DF1 RCCF DF2 HVDR F CM BC 1 EM 3 BC TB1 TR BC 208-240V 1 TR 24V NOTES: R R HVDR EBTDR BC EBTDR DFT R W2 LVDR DC Y DFT C RVC OPTIONAL HIGH VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRE CODE BK BLACK BL BLUE BR BROWN GR GREEN OR ORANGE PK PINK PU PURPLE RD RED WH WHITE YL YELLOW BL/PK BLUE WITH PINK STRIP YL/PK YELLOW WITH PINK STRIP THERMOSTAT FIELD WIRING NO ECONOMIZER < , 7 > >> ( 4 WH GR RD YL BL OR 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. USE COPPER CONDUCTORS ONLY ++ USE N.E.C. CLASS 2 WIRE 3. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY. O LPS O < , 7 > >> ( 4 WH GR RD YL BL OR R W2 O W1 THERMOSTAT Y/ Y2 6 5 4 PLF2 3 2 1 Y1 G SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION C SEE NOTE #3 < , 7 > ( 4 STAT 2 STAGE COOLING C HPS > ( 4 WITH ECONOMIZER OPTION TB1 P 4 L F 5 1 6 < , 7 STAT TB1 C G R R BLOWER CONTACTOR CONTACTOR CONDENSER MOTOR COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT ECONOMIZER ELECTRONIC BLOWER TIME DELAY EVAPORATOR MOTOR RELAY RELAY EVAPORATOR MOTOR FAN CAPACITOR EQUPIMENT GROUND HIGH PRESSURE SWITCH HIGH VOLTAGE DEFROST RELAY LOW PRESSURE SWITCH LOW VOLTAGE DEFROST RELAY LOW VOLTAGE JUNCTION BOX POWER DISTRIBUTION BLOCK FEMALE PLUG / CONNECTOR REVERSING VAVLE COIL RUN CAPACITOR FOR CONDENSER FAN TERMINAL BLOCK (24V SIGNAL) TRANSFORMER 3 TB1 EBTDR LINE VOLTAGE LOW VOLTAGE COMPONENT LEGEND 208-240/3/60 0140L00064 REV. C < , 7 > >> ( 4 WH GR RD YL PK BL OR TB1 < , 7 > > ( 4 STAT Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. WARNING SS-CPH36-60 High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. www.goodmanmfg.com 33 PRODUCT SPECIFICATIONS WIRING DIAGRAM — CPH60***4B (460V BELT DRIVE) OR BK RD RD BL 85**) :5 BL 3 1 G EBTDR R XFMR-R XFMR-C C BL S2 K1 NO K1 COM S1 RD 480 PK YL T3 L3 RD RD T2 L2 OR C BL REPLACE JUMPER WITH SMOKE/FIRE DETECTOR BK BK BK SEE NOTE #2 L1 T1 YL YL/PK GND YL DC OR GR PLF 2 YL C YL Y O OR O BK LVDR GR T1 T2 RD R HVDR C RCCF F 3 6 9 2 5 8 PU YL RD GR WH BR OR BL 1 4 7 RD GR WH OR BL DFT T3 DF1 DF2 RD BL RD BR BC 1 RD RD WH PU BK C BK YL BL LVJB RD R L3 3 6 2 5 1 4 WH W2 L2 PU BR RD BL L1 4 6 0 / 3 / 6 0 RD BL BL PB BL C 24V TB1 GR BK RD BL TR PU NC M2 M1 BL RD GR OR BK OR RD PU 3 CMR 2 OR PLF 1 BL T H E R M O S T A T Y1 Y/Y2 R G W1 W2 O C TB1 RD RD RD RD PU BK BR BK BK YL/PK BL/PK YL CONTROL BOX T3 T1 T2 EM DFT BK CM HPS COMP LPS RVC L1 T2 C T1 BC C CM CMR COMP DC DFT ECON EBTD EMR R EM FC GND HPS HVDR LPS LVDR LVJB PB PLF RVC RCCF C COMP C T3 T3 C DF1 RCCF DF2 HVDR F CM BC 1 EM 3 BC 460V BC 1 TB1 TR 3 TB1 24V NOTES: R CMR EBTDR R BC EBTDR DFT R W2 LVDR DC Y DFT C RVC OPTIONAL HIGH VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRE CODE BK BLACK BL BLUE BR BROWN GR GREEN OR ORANGE PK PINK PU PURPLE RD RED WH WHITE YL YELLOW BL/PK BLUE WITH PINK STRIP YL/PK YELLOW WITH PINK STRIP THERMOSTAT FIELD WIRING NO ECONOMIZER < , 7 > >> ( 4 < , 7 WH GR RD > ( 4 YL BL OR STAT TB1 C G R R HVDR BLOWER CONTACTOR CONTACTOR CONDENSER MOTOR CONDENSER MOTOR RELAY COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT ECONOMIZER ELECTRONIC BLOWER TIME DELAY EVAPORATOR MOTOR RELAY RELAY EVAPORATOR MOTOR FAN CAPACITOR EQUPIMENT GROUND HIGH PRESSURE SWITCH HIGH VOLTAGE DEFROST RELAY LOW PRESSURE SWITCH LOW VOLTAGE DEFROST RELAY LOW VOLTAGE JUNCTION BOX POWER DISTRIBUTION BLOCK FEMALE PLUG / CONNECTOR REVERSING VAVLE COIL RUN CAPACITOR FOR CONDENSER FAN TERMINAL BLOCK (24V SIGNAL) TRANSFORMER TR EBTDR LINE VOLTAGE LOW VOLTAGE COMPONENT LEGEND T2 T1 FACTORY WIRING L3 L2 SUPPLY VOLTAGE 460/3/60 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. USE COPPER CONDUCTORS ONLY ++ USE N.E.C. CLASS 2 WIRE 3. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY. O WITH ECONOMIZER OPTION < , 7 > >> ( 4 < , 7 > WH GR RD YL ( 4 BL OR STAT TB1 LPS O P 4 L F 5 1 6 R W2 O W1 THERMOSTAT Y/ Y2 2 STAGE COOLING C HPS 6 5 4 PLF2 3 2 1 Y1 SEE NOTE 5 G SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION C SEE NOTE #3 460/3/60 0140L00017 REV. C < , 7 > >> ( 4 < , 7 > > ( 4 WH GR RD YL PK BL OR STAT TB1 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. WARNING 34 High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. www.goodmanmfg.com SS-CPH36-60 PRODUCT SPECIFICATIONS WIRING DIAGRAM — CPH60***7B*** (575V, BELT DRIVE) OR BK BK OR OR RD RD RD BL 85**) :5 BL RD GR S1 PK S2 G EBTDR R XFMR-R XFMR-C C BL K1 NO K1 COM RD 1 3 575 C BK RD BL YL T3 L3 RD RD T2 L2 PB OR 5 7 5 / 3 / 6 0 TR 24V TB1 GR BL BL REPLACE JUMPER WITH SMOKE/FIRE DETECTOR BK BK PU NC M2 M1 BL RD C BK SEE NOTE #2 L1 T1 YL YL/PK GND C LVDR GR O OR O BK PU BR RD WH RD RD R HVDR C RCCF F DF1 RD BL RD 6 5 9 8 1 4 7 1 RD PU 3 CMR 2 OR WH OR BR BC RD 3 2 GR DFT T3 DF2 BK PU YL RD GR WH BR OR BL PLF 1 BK C T2 T1 LVJB WH R L3 YL BL RD W2 L2 L1 3 6 2 5 1 4 YL BL BL YL GR YL Y DC PLF 2 OR BL BL T H E R M O S T A T Y1 Y/Y2 R G W1 W2 O C TB1 RD RD PU BK EM BL/PK RD RD BR BK YL T3 T1 T2 DFT BK CONTROL BOX YL/PK BK HPS CM COMP LPS RVC L1 T2 C T1 C T3 T3 DF1 RCCF DF2 HVDR F CM BC 1 EM 3 BC 575V BC 3 TB1 TR 1 TB1 TR 24V EBTDR NOTES: R CMR EBTDR R BC EBTDR DFT R W2 LVDR DC Y DFT C RVC OPTIONAL HIGH VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRE CODE BK BLACK BL BLUE BR BROWN GR GREEN OR ORANGE PK PINK PU PURPLE RD RED WH WHITE YL YELLOW BL/PK BLUE WITH PINK STRIP YL/PK YELLOW WITH PINK STRIP THERMOSTAT FIELD WIRING NO ECONOMIZER < , 7 > >> ( 4 WH GR RD YL BL OR 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. USE COPPER CONDUCTORS ONLY ++ USE N.E.C. CLASS 2 WIRE 3. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY. O LPS O < , 7 > >> ( 4 WH GR RD YL BL OR 6 5 4 PLF2 3 2 1 6 R W2 O W1 THERMOSTAT Y/ Y2 Y1 SEE NOTE 5 G SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION C SEE NOTE #3 < , 7 > ( 4 STAT 2 STAGE COOLING C HPS > ( 4 WITH ECONOMIZER OPTION TB1 P 4 L F 5 1 < , 7 STAT TB1 C G R R HVDR BLOWER CONTACTOR CONTACTOR CONDENSER MOTOR CONDENSER MOTOR RELAY COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT ECONOMIZER ELECTRONIC BLOWER TIME DELAY EVAPORATOR MOTOR RELAY RELAY EVAPORATOR MOTOR FAN CAPACITOR EQUPIMENT GROUND HIGH PRESSURE SWITCH HIGH VOLTAGE DEFROST RELAY LOW PRESSURE SWITCH LOW VOLTAGE DEFROST RELAY LOW VOLTAGE JUNCTION BOX POWER DISTRIBUTION BLOCK FEMALE PLUG / CONNECTOR REVERSING VAVLE COIL RUN CAPACITOR FOR CONDENSER FAN TERMINAL BLOCK (24V SIGNAL) TRANSFORMER BC C CM CMR COMP DC DFT ECON EBTD EMR R EM FC GND HPS HVDR LPS LVDR LVJB PB PLF RVC RCCF C COMP C LINE VOLTAGE LOW VOLTAGE COMPONENT LEGEND T2 T1 FACTORY WIRING L3 L2 SUPPLY VOLTAGE 575/3/60 575/3/60 0140L00067 REV. C < , 7 > >> ( 4 WH GR RD YL PK BL OR TB1 < , 7 > > ( 4 STAT Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. WARNING SS-CPH36-60 High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. www.goodmanmfg.com 35 PRODUCT SPECIFICATIONS ACCESSORIES Item # Description Fits Model Sizes Dimensions (“) Ship Weight 16 x 6 x 76 119 14CURB3672 Roof Curb – 14” Tall 3-6 tons 25FD3672 25% Manual Fresh Air Damper 3-6 tons 11 25MFD3672 25% Motorized Fresh Air Damper 3-6 tons 12 CDK36 Concentric Duct Kit 3 tons 25 x 48 x 16 35 CDK4872 Concentric Duct Kit 4-6 tons 25 x 48 x 16 35 DNECONGS3672 Downflow Economizer for CPC/CPG 3-6 tons 32½ x 20½ x 38 75 DNECONHP3672 Downflow Economizer for CPH 3-6 tons 32½ x 20½ x 38 75 DNSQRRND36 Downflow Square-to-Round Adapter – 16” Round 3 tons DNSQRRND4872 Downflow Square-to-Round Adapter – 18” Round 4-6 tons HailGD01 Condenser Coil Hail Guard 3-6 tons HAKT36300 High-Altitude Kit 3-5 tons HZECONGS3672 Horizontal Economizer for CPC/CPG 3-6 tons 75 HZECONHP3672 Horizontal Economizer for CPH 3-6 tons 75 LPKT36150 LP Conversion Kit 40 x 36 x 2 All Models Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2008 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. 36 www.goodmanmfg.com SS-CPH36-60
Similar documents
Commercial Products Catalog - Tasso Lake Heating Solutions
• Steel louver coil guard protects coil from damage and adds strength to the unit • Heavy-gauge, galvanized-steel cabinet • Attractive architectural gray powder-paint finish with 500-hour salt-s...
More information