araya® Color Tuning LED Modules CTM 119 and CTM 119NR

Transcription

araya® Color Tuning LED Modules CTM 119 and CTM 119NR
THE TRUE AND PERFECT LIGHT
araya Color Tuning LED Modules
CTM 119 and CTM 119NR (1200 Maximum Peak Lumens)
CTM 112 (1000 Maximum Peak Lumens)
CTM 109 (875 Maximum Peak Lumens)
Installation and Operation Guide
®
TABLE OF CONTENTS
1 Introduction
2
2 Heat Sinking
3
2.1 Compatible Heat Sinks
2.2 Mechanical Attachment of the Heat Sink
3 Power Supplies
5
3.1 Electrical Specifications
3.2 Recommended Power Supplies
4 CTM One Case Temperature Measurement 6
5 Secondary Optics
7
5.1 Attaching Reflectors
5.2 Compatible Reflectors
6 CTM One Cable Assemblies
10
7 CTM One Wiring Diagrams
12
7.1 Wireless Operation using LCT (to control CCT, Dimming, Saturation, Hue)
7.2 0-10V Control of CCT & Dimming / LCT Control of Saturation & Hue
7.3 0-10V Control of Dimming / LCT Control of CCT, Saturation & Hue
7.4 0-10V Control of SceneSet® / LCT to Set or Amend Scenes
7.5 Digital Control Adapter (DCA) for DALI, DMX, and Lutron EcoSystem®
7.6 Digital Control Adapter (DCA) for Bluetooth
8 CTM 109, CTM 112, CTM 119 and CTM 119NR Operation Guide
ii | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide
18
1 INTRODUCTION
This Installation and Operation Guide covers the following araya® Color Tuning Modules (CTM):
CTM 109
CTM 112
CTM 119
CTM 119NR
For complete Color Tuning Module specifications, please visit: www.lumenetix.com/downloads
This Installation and Operation Guide covers heat sinking, case temperature measurement, secondary optics,
power supply and wiring diagrams for wireless operation using the Lumenetix Light Commissioning Tool (LCT),
industry standard 0-10V wired controls or a hybrid operation that combines hard wired and wireless control.
For long term reliable operation, proper heat sinking is critical.
The CTM is fragile. Avoid touching the diffuser during
handling and assembly.
Do not rest or operate the CTM face down against a table
or other solid surface.
2 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide
2 HEAT SINKING
The Color Tuning Module requires an external heat sink in order to ensure proper operating temperature of the LEDs.
The CTM has a conductive aluminum case and an efficient thermal path to the LED array. These features promote
efficient thermal management and allow for a simple heat sink design in most applications.
Examples of heat sinking methods are cast or extruded heat sinks. Both carbon and stainless steel are much less efficient
at transferring heat than aluminum and therefore are not recommended as heat sink materials. The heat sink mounting
surface should be flat and smooth. Metal-to-metal contact surfaces will result in best performance; anodized or unfinished
mounting surfaces are recommended. Mounting the CTM on a painted aluminum surface will reduce the performance
of the heat sink material.
2.1 Compatible Heat Sinks
The following tables list heat sinks models that have compatible form factors and thermal resistance characteristics for use
with the CTM. The thermal resistances assume an approximate ambient temperature of 25C. The heat sinks listed here
are suggestions only.
MechaTronix (round)
Part Number
Dia. (mm)
Height (mm)
Thermal Resistance (°C/W)
LSB9950
99
50
1.3 – 1.5
LSB9980
99
80
1.2 – 1.4
Nano 7080
70
80
1.8
Micro 8630
86
30
1.8
Micro 8650
86
50
1.5
Micro 8680
86
80
1.2
IMPORTANT: These heat sinks are qualified in “free air”. If the CTM is installed in an insulated can fixture (IC Can), the
module may exceed the recommended operating temperature. The heat sink must be evaluated and temperature
tested in the fixture at applicable ambient temperatures for the desired application.
Additional product information at www.led-heatsink.com
Aavid Thermalloy Heat Sink Extrusions (square/rectangular)
Part Number
Width (mm)
Length
Height (mm)
Thermal Resistance (°C/W)
67590
88
88
31
1.5 – 1.7
61085
136
85
33
1.4 – 1.6
Additional product information at www.aavid.com
3 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide
2.2 Mechanical Attachment of the Heat Sink
The CTM One light engines have a Zhaga-compliant front mount option for heat sink mounting, using two 4-40 or M2.5 screws.
Mechanical Specifications
Dimensions
8
Diameter:
1.97 inches (50 mm)
Height:
0.67 inches (17 mm); CTM 119NR: 0.84 inches (21.44 mm)
Light Emitting Surface
9.5, 12.75 and 22 mm
Weight
0.12 pounds (0.06kg)
Heat Sink Attachment
Front mount, M2.5 or 4-40 Screws
Max Case Temperature
<80°C
5
6
7
4
2
3
5X
2X
CTM 119NR – Raised Face
5X
50
1.97
3.40 THRU
.13
5
6
7
35 B.C.
1.38
50
1.97
D
1
8
CTM 119, CTM 112, CTM 109
4
35 B.C.
1.38
2X 3.40 THRU
.13
USE M3X0.5 SCREW
D
D
3X
1.30 4
.05
USE M1.8 X4
SCREW
(REFLECTOR ATTACHMENT)
C
Model
CTM1-19
LES Diameter
CTM 109
67°
37°
53°
C
EMITTING
MODEL LIGHT
SURFACE DIA
C
22mm
12.75mm
CTM1-12
CTM1-09
9.5 mm (0.37
inches)9mm
CTM 112
12.75 mm (0.50 inches)
CTM 119
22 mm (0.87 inches)
.866".
.502"
.354"
37°
67°
53°
B
B
B
17
.67
21.44
.84
A
UNLESS OTHERWISE SPECIFIED:
NAME
DATE
DIMENSIONS ARE IN MILLIMETERS DRAWN
TOLERANCES:
CHECKED
ANGULAR: MACH 0.5
ONE PLACE DECIMAL
0.5
ENG APPR.
TWO PLACE DECIMAL
0.15
A.N.
05/13/13
MFG APPR.
A
INTERPRET GEOMETRIC
TOLERANCING PER: ASME Y14.5
PROPRIETARY AND CONFIDENTIAL
Lumenetix
UNLES
TITLE:
DIMEN
TOLER
ANGU
ONE P
TWO P
A
CTM-12V, 19 DIA, FINAL ASSEMBLY
Q.A.
COMMENTS:
SIZE DWG. NO.
REV
NOTES
Note: Upper dimensions areSEEin
inches; lower dimensions
are in millimeters.
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
LUMENETIX. ANY REPRODUCTION IN
PART OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF LUMENETIX
IS PROHIBITED.
8
7
6
5
MATERIAL
USED ON
NEXT ASSY
APPLICATION
4
1
B
FINISH
SHEET 2 OF 2
SCALE: 1:1 WEIGHT:
DO NOT SCALE DRAWING
2
3
8
Figure 1: Heat Sink Attachment Specifications
4 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide
1
7
INTERPR
TOLERA
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
LUMENETIX. ANY REPRODUCTION IN
PART OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF LUMENETIX
IS PROHIBITED.
6
5
MATER
USED ON
NEXT ASSY
APPLICATION
4
FINISH
DO
3 POWER SUPPLY REQUIREMENTS
3.1 Electrical Specifications
Description and Nominal Power Input
CTM 109/112/119/119NR, 12.5W
CTM 109/112/119/119NR, 20W
Input Voltage
12V DC
12V DC
Nominal Current Input
12.5W: 1.0A
20W: 1.7A
Power Supply Classification
Class 2
Class 2
IMPORTANT
The Color Tuning Module has on-board drive electronics, including dimming. A dimming driver is NOT required.
3.2 Recommended Power Supplies (Constant Voltage)*
Manufacturer
Part Number
Rated Power
Input Voltage
Mean Well
APV-35-12
35W
90V - 264V
Mean Well
LPV-60-12
60W
90V - 264V
Mean Well
LPV-100-12
100W
90V - 264V
Roal
RSLP070-12
48W
120V - 277V
Inventronics
EUV-025S012PS
25W
120V - 277V
Inventronics
EUV-050S012ST
50W
120V - 277V
Thomas Research
LED24W-12
25W
120V - 277V
Thomas Research
LED50W-12
50W
120V - 277V
Thomas Research
PLED75W-012
75W
120V - 277V
Excelsys Technologies
LXV25-012SW
25W
120V - 277V
Excelsys Technologies
LXV50-012SW
50W
120V - 277V
Excelsys Technologies
LXV75-012SW
75W
120V - 277V
Excelsys Technologies
LXV100-012SW
100W
120V - 277V
*IMPORTANT: Using a constant current power supply will damage the module, and will void the Lumenetix warranty.
Using a triac or dimming driver will damage the module, and will void the Lumenetix warranty.
NOTE: Recommendations are subject to change. Consult your Lumenetix representative for the most updated list.
5 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide
4 CTM ONE CASE TEMPERATURE MEASUREMENT
The thermal management characteristics of the heat sink used with the CTM One should be validated by measuring its
case temperature. This test should be done with the CTM One installed in the fixture at ambient temperature and air
flow conditions similar to the end-use installation.
The power draw of the CTM One family varies by approximately one watt over the CCT range with peak power draw occurring at
the CCT shown in the following table. The case temperature should be measured at the following CCT setting.
CCT Setting for Case Temperature (Tc) Measurement
CCT range
CCT Setting to Measure Tc
1650 – 4000K
3500K
The proper case temperature measurement location is on the narrow metal band, next to the power lead port; see Figure 2.
The case temperature reading should be made after the unit has reached steady state, where the case temperature levels out.
It is recommended to design the thermal management system for a case temperature of 80˚C.
Maximum case temperature: 80˚C
The Color Tuning Module has on-board thermal protection to reduce the current to the LEDs when the maximum case
temperature is exceeded. This prevents unacceptably high LED junction temperatures by slightly dimming the module.
CASE TEMPERATURE
MEASUREMENT
POINT
Figure 2: Case Temperature Measurement Point
6 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide
5 SECONDARY OPTICS
5.1 Attaching Compatible CTM One Reflectors
The CTM 119NR accepts twist-to-lock reflectors with an attachment collar. The CTM 109, CTM 112 and CTM 119
have provisions for front mount reflectors and TE Type-2 clip reflectors. The fastener specifications are shown in
the following table while mounting hole locations are shown in Figures 3, 4 & 5.
CTM One Secondary Optics Fastener Specifications
CTM One Reflector
Fastener specifications
Screw length
Notes
Twist Lock w/ Collar (CTM 119NR)
Front Mount
2 - 28; M1.8 x 6
6 mm (1/4”)
Thread forming; use flat head screws
2 - 28; M1.8 x 4
4 mm (1/6”)
Thread forming
TE Type 2 Clip
M3-0.5 x 25
25 mm (1”)
Machine screws; attach to heat sink
(not directly to module)
M1.8 x 4; 2 - 28
THREAD FORMING
M1.8 x 6; 2 - 28
THREAD FORMING
USE FLAT HEAD SCREWS
Figure 3: CTM 119NR Twist-Lock Style
Reflectors with Attachment Collars
M3-0.5 x 25
MACHINE SCREW
Figure 4: CTM 109 / CTM 112 / CTM 119
Front (Screw) Attaching Reflectors (by Alux-Luxar)
7 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide
Figure 5: CTM 109 / CTM 112 / CTM 119
TE Type 2 Clip Reflectors (by Khatod)
5.2 Compatible Reflectors
Compatible Reflectors for CTM 109
Manufacturer
M. Part Number
beam angle (deg)
outer dim (mm)
height (mm)
optical finish
optical finish 2
attach method
khatod
khatod
khatod
khatod
Alux Luxar
Alux Luxar
nata
nata
nata
nata
1682 ST
1683ST
1685 ST
1687 ST
XLC 200
TLC 200
4-1406-E
3990E
3991E
3993E
20
24
32
31
22
28
20.3
23.2
35.7
40
65
65
65
65
94
85 / 94
110
75
75
85
35
35
35
35
49.5
50.5
66.2
43
43
50.5
diffuse
diffuse
diffuse
diffuse
diffuse
diffuse
specular
specular
specular
specular
none
none
none
none
panel
faceted
super faceted
super faceted
super faceted
super faceted
TE Type 2 clip
TE Type 2 clip
TE Type 2 clip
TE Type 2 clip
screw
screw
none
none
none
none
Compatible Reflectors for CTM 112
Manufacturer
M. Part Number
beam angle (deg)
outer dim (mm)
height (mm)
optical finish
optical finish 2
attach method
Diffractive Optics
khatod
khatod
khatod
khatod
khatod
khatod
khatod
khatod
Alux Luxar
Alux Luxar
Alux Luxar
Alux Luxar
Alux Luxar
Alux Luxar
Alux Luxar
Alux Luxar
Alux Luxar
nata
nata
nata
nata
nata
Top Lighting
P11218 (LES12)
1682 ST
1683 ST
1684 ST
1685 ST
1687 ST
1688 ST
1690 ST
1691 ST
XLC 100
XLC 200
XLC 500
TLC 500
XLC 1100
TLC 200
TLC 300
XLC 1200
TLC 900
4-1406-E
3990E
3991E
3992E
3993E
XSA-15
16
20
24
28
32
31
38
50
56
18
22
25
26
27
28
46
52
54
20.3
23.2
35.7
24.8
40
60
72.6
65
65
65
65
65
65
65
65
94
94
94
85 / 92
120
85 / 94
85 / 94
120
108 / 120
110
75
75
85
85
70
33
35
35
35
35
35
35
35
35
50.3
49.5
49.5
50
65.7
50.5
50.5
65.7
66.2
66.2
43
43
50.5
50.5
43
specular
diffuse
diffuse
diffuse
diffuse
diffuse
diffuse
diffuse
diffuse
specular
diffuse
diffuse
diffuse
diffuse
diffuse
diffuse
diffuse
diffuse
specular
specular
specular
specular
specular
specular
faceted
none
none
none
none
none
none
none
none
faceted
panel
none
TE Type 2 clip
TE Type 2 clip
TE Type 2 clip
TE Type 2 clip
TE Type 2 clip
TE Type 2 clip
TE Type 2 clip
TE Type 2 clip
screw
screw
screw
screw
screw
screw
screw
screw
screw
none
none
none
none
none
none
faceted
faceted
faceted
faceted
faceted
super faceted
super faceted
super faceted
super faceted
super faceted
none
NOTE: Reflectors have been recommended based on independent optical tests conducted by Lumenetix, and should be used as guidelines.
Final reflector evaluation should be made by fixture manufacturers with all optics in place.
8 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide
Compatible Reflectors for CTM 119 and CTM 119NR
Manufacturer
M. Part Number
beam angle (deg)
outer dim (mm)
height (mm)
optical finish
optical finish 2
attach method
Widegerm
Widegerm
Widegerm
Edison Price
Edison Price
Diffractive Optics
Diffractive Optics
Diffractive Optics
Diffractive Optics
Diffractive Optics
khatod
khatod
khatod
khatod
khatod
khatod
khatod
Alux Luxar
Alux Luxar
Alux Luxar
Alux Luxar
Alux Luxar
Alux Luxar
Alux Luxar
Alux Luxar
Alux Luxar
Alux Luxar
Alux Luxar
nata
nata
nata
Top Lighting
Top Lighting
Top Lighting
3207T-XC
1009T-XC
1010T-XC
770237-D20
770237-D40
P7076 (XSA-17)
P7899 (XSA-22)
P6764 (XSA-21)
P6680
P6645
1682 CR
1682 ST
1683 ST
1685 ST
1687 ST
1688 ST
1689 ST
XLC 1300
XLC 100
XLC 500
XLC 1400
XLC 1100
TLC 200
XLC 800
TLC 300
XLC 1200
TLC 900
XLC 700
4-1406-E
3991E
3993E
XSA-13
XSA-14
XSA-15
38
38
55
20
40
20
40
56
40
65
11
20
24
32
31
38
42
17.6
18
25
25
27
28
42
46
52
54
32
20.3
35.7
40
22
46
60
82
49
50
70
70
94.4
49.3
50
70
70
65
65
65
65
65
65
65
120
94
94
120
120
85 / 94
94
85 / 94
120
108 / 120
94x94
110
75
85
70
70
70
46
30.4
30.4
45
45
83
28.6
29
42
42
35
35
35
35
35
35
35
65.6
50.3
49.5
65.6
65.7
50.5
49.5
50.5
65.7
66.2
50.1
66.2
43
50.5
43
43
43
diffuse
specular
specular
specular
specular
specular
specular
specular
specular
specular
specular
diffuse
diffuse
diffuse
diffuse
diffuse
diffuse
diffuse
specular
diffuse
diffuse
diffuse
diffuse
diffuse
diffuse
diffuse
diffuse
diffuse
specular
specular
specular
specular
specular
specular
none
faceted
none
faceted,sq
faceted, sq
faceted
faceted
none
none
none
none
none
none
none
none
none
none
panel
faceted
twist lock*
twist lock*
twist lock*
twist lock*
twist lock*
twist lock*
twist lock*
twist lock*
twist lock*
twist lock*
TE Type 2 clip
TE Type 2 clip
TE Type 2 clip
TE Type 2 clip
TE Type 2 clip
TE Type 2 clip
TE Type 2 clip
screw
screw
screw
screw
screw
screw
screw
screw
screw
screw
screw
none
none
none
none
none
none
faceted
faceted
faceted
faceted
faceted
faceted
faceted
none
super faceted
super faceted
super faceted
none
none
none
NOTE: Reflectors have been recommended based on independent optical tests conducted by Lumenetix, and should be used as guidelines.
Final reflector evaluation should be made by fixture manufacturers with all optics in place.
9 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide
6 CTM ONE CABLE ASSEMBLIES
6.1.1 Power Cable Assembly
Provides power to each module.
Lumenetix part #: 28.002.001.01
3
4
2
1
PIN ONE
6.35
610
Note: All dimensions are in millimeters.
ITEM NO.
PART NUMBER
DESCRIPTION
1
874390200
MOLEX CONNECTOR
1
2
874210000
MOLEX CRIMP
2
3
A2015R-100-ND
24 AWG WIRE, RED
1
4
A2015B-100-ND
24 AWG WIRE, BLACK
1
Figure 6: Power Cable Assembly
6.1.2 Pin Allocation Chart for Power Cable Assembly
Pin #
Lead Color
Input
Pin 1
Red
Power 24V DC
Pin 2
Black
Power GND
10 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide
QTY.
6.2.1 Control Cable Assembly
Provides 0-10V control and RS-485 signals to each module.
Lumenetix part #: 28.002.002.01
7X STRIP AND TIN
9
8
7
6
5
4
3
2
1
8±1.50
610 10
Note: All dimensions are in millimeters.
ITEM NO.
PART NUMBER
DESCRIPTION
QTY.
1
874390700
MOLEX CONNECTOR
1
2
874210000
MOLEX CRIMP
7
3
A2015V-100-ND
24 AWG WIRE, VIOLET
1
4
A2015L-100-ND
24 AWG WIRE, BLUE
1
5
A2015A-100-ND
24 AWG WIRE, ORANGE
1
6
A2015G-100-ND
24 AWG WIRE, GREEN
1
7
A2015N-100-ND
24 AWG WIRE, BROWN
1
8
A2015S-100-ND
24 AWG WIRE, GREY (SLATE)
1
9
A2015W-100-ND
24 AWG WIRE, WHITE
1
Figure 7: Control Cable Assembly
6.2.2 Pin Allocation Chart for Control Cable Assembly
Pin #
Lead Color
Input
Pin 1
Violet
0-10V Dimming
Pin 2
Blue
0-10V Color
Pin 3
Orange
RS-485 (A)
Pin 4
Green
RS-485 (B)
Pin 5
Brown
Digital GND
Pin 6
Gray
Signal GND for 0-10V Dimming
Pin 7
White
Signal GND for 0-10V Color
11 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide
7 CTM ONE WIRING DIAGRAMS
7.1 Wireless Operation using LCT (to control CCT, Dimming, Saturation and Hue)
Wireless Operation. CTM is shipped with the wireless mode enabled as the two pairs of control wires are grounded.
In this mode the Light Commissioning Tool (LCT) provides complete control of the CCT, Dimming, Saturation & Hue.
LCT
INPUT
LCT WIRELESS
INPUT
DIMMING
LCT WIRELESS
CCT / SAT/ HUE
100%
1%
CTM One
CTM One
+
–
12V DC POWER SUPPLY
+
(110V/277V AC)
FROM SWITCHED CONTROL
Figure 8: Wireless Operation using LCT
Lead Color and Input
Lead Color
Input
Red
Positive 24V
Black
Negative
Violet
Connect to Common
Gray
Common
White
Common
Blue
Connect to Common
Lumenetix part #s:
28.002.001.01 (power cable assembly)
28.002.002.01 (control cable assembly)
12 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide
7.2 0-10V Control of Continuous CCT and Dimming / LCT Control of Saturation and Hue
0-10V Continuous CCT Control. Remove power from the CTM. Connect a 0-10V control device to the blue (+) and white
(ground) wires. When the CTM is powered up, the 0-10V control will adjust the CCT over the tunable range. The Light
Commissioning Tool (LCT) will control Dimming and Saturation and Hue. A 0-10V control may also be added for dimming
(as shown). LCT adjustments to Dimming levels are a percentage of the 0-10V Dim setting (Trim). If a 0-10V control is not
used for dimming, the gray (ground) and violet (+) wires must be grounded together.
INPUT
LCT WIRELESS
CCT / SAT/ HUE
CCT
DIM
INPUT
LCT
10 V
COMMON
INPUT
DIMMING
COMMON
Continuous CCT
CTM One
BLUE
0V
WHITE
1%
GRAY
VIOLET
100%
+
CTM One
–
12V DC POWER SUPPLY
+
(110V/277V AC)
FROM SWITCHED CONTROL*
Figure 9: 0-10V Control of Continuous CCT and Dimming
Lead Color and Input
Lead Color
Input
Red
Positive 24V
Black
Negative
Violet
0-10V Dimming
Gray
Common
White
Common
Blue
0-10V CCT
Notes:
1. If SceneSet® is not activated using the LCT, the CTM defaults to
0-10V control of the continuous CCT range.
2. If 0-10V control is not being used for dimming, the violet control
lead must be grounded to gray common lead.
3. CTM sources current to 0-10V control at 0.2mA nominal capacity.
4. *
If using a wall box dimmer, power only the DIM unit. The CCT
unit does not get line-in voltage.
Lumenetix part #s:
28.002.001.01 (power cable assembly)
28.002.002.01 (control cable assembly)
13 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide
7.3 0-10V Control of Dimming / LCT Control of CCT, Saturation and Hue
0-10V Dimming Control Only. Remove power from the CTM. Connect a 0-10V control device to violet (+) and gray
(ground) wires. When the CTM is powered up, the 0-10V control device will adjust Dimming from 100-1%. Use the Light
Commissioning Tool (LCT) to set CCT, Dimming, Saturation, and Hue to the desired levels and use Copy and Paste functions
to match lamp settings. In this configuration, the LCT trims the dimming level, i.e., adjustments to Dimming levels as a
percentage of the 0-10V Dimming setting (Trim). Preset controls are not available in this configuration.
0-10 V CONTROLLER
LCT
DIM
INPUT
10 V
COMMON
INPUT
DIMMING
LCT WIRELESS
CCT / SAT / HUE
0V
CTM One
GRAY
1%
VIOLET
100%
+
CTM One
–
12V DC POWER SUPPLY
+
(110V/277V AC)
FROM SWITCHED CONTROL*
Figure 10: 0-10V Control of Dimming Only
Lead Color and Input
Lead Color
Input
Red
Positive 24V
Black
Negative
Violet
0-10V Dimming
Gray
Common
1. C
TM sources current to 0-10V control at 0.2mA
nominal capacity.
White
Common
2. Only pins 1 and 6 are used.
Blue
Connect to Common
Lumenetix part #s:
28.002.001.01 (power cable assembly)
28.002.002.01 (control cable assembly)
Notes:
3. *If using a wall box dimmer, power only the DIM
unit. The CCT unit does not get line-in voltage.
14 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide
7.4 0-10V Control of SceneSet® / LCT to Set or Amend SceneSet®
0-10V Preset Control. Remove power from the CTM. Connect a 0-10V control device to the blue (+) and white (ground)
wires. Use the Light Commissioning Tool (LCT) to set, store and enable up to five preset scenes comprised of CCT, Dimming
and Saturation & Hue levels. The 0-10V control will toggle between the preset scenes. A 0-10V control may also be added
for dimming (as shown) and will proportionally Dim from the stored value in the preset. If a 0-10V control is not used for
dimming, the gray (ground) and violet (+) wire must be grounded together.
CCT
DIM
INPUT
LCT
10 V
COMMON
INPUT
COMMON
DIMMING
SCENESET®
100%
SCENE 5
SCENE 4
CTM One
SCENE 2
BLUE
0V
WHITE
1%
GRAY
VIOLET
SCENE 3
SCENE 1
+
CTM One
–
12V DC POWER SUPPLY
+
(110V/277V AC)
FROM SWITCHED CONTROL*
Figure 11: 0-10V SceneSet® Control
Lead Color and Input
Lead Color
Input
Red
Positive 24V
Black
Negative
Violet
0-10V Dimming
Gray
Common
White
Common
Blue
0-10V Presets
Notes:
1. SceneSet® is commissioned and activated using the LCT.
See LCT operating instructions.
2. If 0-10V control is not being used for dimming, the violet
control lead must be grounded to gray common lead.
3. CTM sources current to 0-10V control at 0.2mA
nominal capacity.
4. *
If using a wall box dimmer, power only the DIM unit.
The CCT unit does not get line-in voltage.
Lumenetix part #s:
28.002.001.01 (power cable assembly)
28.002.002.01 (control cable assembly)
15 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide
7.5 Digital Control Adapter (DCA) for DALI, DMX, and Lutron Ecosystem®
Notes:
1. Ground from external adapter (brown) does not need to be connected if the araya®
module and the Digital Control Adapter use a common power supply.*
*Depending on the application, wiring may be connected through but left
unconnected in the junction box.
2. Maximum of 30 luminaires in Parallel/Star with two 120Ω terminators at end of run;
max distance of 900 feet.
Every luminaire consumes “DMX” energy. A maximum of 30 devices can be connected
to one DMX line. After this, the signal needs to be boosted with a DMX-Booster. The
“4 way optosplitter” splits and boosts the DMX signal.
For DMX inputs:
Black wire is Ground
Violet is Data Positive
Gray is Data Negative
Brown
Orange
Green
EcoSystem®
or DALI
4. A
dapter is configured at factory for EcoSystem®, DALI, DMX or Bluetooth inputs.
5. Module Data +/- (green/orange) to araya® modules is class 2 rated.
6. Control Field Wiring:
Liberty cable
24-2P-485 Non-Plenum
24-2P-P485 Plenum
DMX
Black
Violet
Gray
3. 12V power (red/black) is class 2 rated.
PN: 28.020.001.01
Belden cable
9842 Non-Plenum
89842 Plenum
Please refer to wire manufacturer’s lighting catalog for and/equals as required by code.
7. C
AUTION: The power cable should ONLY be plugged into the 2-pin power
receptacle provided. Insertion of the cable into any other slot will damage
the Digital Control Adapter unit.
Digital Control Adapter
PN: 28.002.001.01
PN: 28.020.002.01
Locate at Control System
+
–
Black
CTM One
Red
PN: 28.002.002.03
12V DC, Class 2
AC to DC Power Supply
Black
White
PN: 28.002.002.01
Line in Voltage
(110V/277V AC)
From Switched Control
CTM One
+
–
Black
Hot
Red
Neutral
(FIXTURE 1)
PN: 28.002.002.01
Black
White
12V DC, Class 2
AC to DC Power Supply
Line in Voltage
(110V/277V AC)
From Switched Control
Neutral
(FIXTURE 2)
Figure 12: DCA for DALI, DMX, and Lutron Ecosystem®
16 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide
Hot
7.6 Digital Control Adapter (DCA) for Bluetooth
Notes:
1. G
round from external adapter (brown) does not need to be connected if the araya®
module and the Digital Control Adapter use a common power supply.*
*Depending on the application, wiring may be connected through but left
unconnected in the junction box.
2. Maximum of 30 luminaires in Parallel/Star with two 120Ω terminators
at end of run; max distance of 900 feet.
Every luminaire consumes “DMX” energy. A maximum of 30 devices can be connected
to one DMX line. After this, the signal needs to be boosted with a DMX-Booster. The
“4 way optosplitter” splits and boosts the DMX signal.
4. A
dapter is configured at factory for EcoSystem®, DALI, DMX or Bluetooth inputs.
NOT USED
5. M
odule Data +/- (green/orange) to araya® modules is class 2 rated.
6. Control Field Wiring:
Liberty cable
24-2P-485 Non-Plenum
24-2P-P485 Plenum
Brown
Orange
Green
3. 12V power (red/black) is class 2 rated.
NOT USED
Belden cable
9842 Non-Plenum
89842 Plenum
Please refer to wire manufacturer’s lighting catalog for and/equals as required by code.
7. C
AUTION: The power cable should ONLY be plugged into the 2-pin power
receptacle provided. Insertion of the cable into any other slot will damage
the Digital Control Adapter unit.
Digital Control Adapter
PN: 28.002.001.01
PN: 28.020.002.01
Locate at Control System
+
–
Black
CTM One
Red
PN: 28.002.002.03
12V DC, Class 2
AC to DC Power Supply
Black
White
PN: 28.002.002.01
Line in Voltage
(110V/277V AC)
From Switched Control
CTM One
+
–
Black
Hot
Red
Neutral
(FIXTURE 1)
PN: 28.002.002.01
Black
White
12V DC, Class 2
AC to DC Power Supply
Line in Voltage
(110V/277V AC)
From Switched Control
Neutral
(FIXTURE 2)
Figure 13: DCA for Bluetooth
17 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide
Hot
8 CTM ONE OPERATION GUIDE
The araya® Color Tuning Modules CTM 109, CTM 112, CTM 119 and CTM 119NR utilize standard 0-10V building
controls and/or a wireless Light Commissioning Tool (LCT) for controlling on-Planckian correlated color temperatures
(CCT), dimming values, off-Planckian color points (color tinting) using the Saturation & Hue feature, and
commissioning and activating SceneSet®. This document describes how to control the CTM utilizing 0-10V
controls, the wireless remote or a combination of the two.
Light Commissioning Tool (LCT). The araya® LCT \wirelessly controls the CTM. While the LCT can act as
a stand-alone wireless controller, it is primarily intended to commission the CTM after installation. Each CTM has
a unique address and the operator uses the LCT to select the desired CTM, turn power on/off and then set CCT,
Dim, Saturation & Hue, and set Scene Presets. The LCT can also be used to trim the dimming levels when
0-10V dimming control is enabled. Consult the LCT Operation Guide for detailed instructions.
0-10V Control. The CTM has 0-10V control wire pairs to control Dimming and CCT. Dimming is controlled
by the violet (+) and grey (ground) wires. CCT is controlled by the blue (+) and white (ground) wires. When
a control wire pair is grounded together, the 0-10V control mode is disabled, and the corresponding function
is controlled via the LCT.
Hybrid (wired & wireless) Control. 0-10V controls and the LCT can be used together to control the CTM.
These are the features:
Trim. When 0-10V Dimming is enabled, the LCT can adjust the dimming level as a percentage of
the 0-10V wired setting.
SceneSet®. The LCT can set up to 5 Scene Presets which are recalled using a wired 0-10V controller.
A scene is comprised of a CCT, Dim and Saturation & Hue level. Individual preset scenes also can be
modified and activated with the LCT .
On-Off Control. The CTM may be turned on-off by switching the input power from the 12V supply. To store the
settings, the lamp needs to remain on for at least 45 seconds after the CTM is initially set using the LCT. When Scene
Presets are activated using the LCT, the settings are stored immediately and no wait time is needed. The lamp may
also be turned on-off using the LCT without switching the power supply, but a power draw of about 1W will remain.
18 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide
Lumenetix Inc.
4742 Scotts Valley Drive
Scotts Valley, CA 95066
877.805.7284
www.lumenetix.com
Revised 06.29.15
Specifications subject to
change without notice