araya® Color Tuning LED Modules CTM 119 and CTM 119NR
Transcription
araya® Color Tuning LED Modules CTM 119 and CTM 119NR
THE TRUE AND PERFECT LIGHT araya Color Tuning LED Modules CTM 119 and CTM 119NR (1200 Maximum Peak Lumens) CTM 112 (1000 Maximum Peak Lumens) CTM 109 (875 Maximum Peak Lumens) Installation and Operation Guide ® TABLE OF CONTENTS 1 Introduction 2 2 Heat Sinking 3 2.1 Compatible Heat Sinks 2.2 Mechanical Attachment of the Heat Sink 3 Power Supplies 5 3.1 Electrical Specifications 3.2 Recommended Power Supplies 4 CTM One Case Temperature Measurement 6 5 Secondary Optics 7 5.1 Attaching Reflectors 5.2 Compatible Reflectors 6 CTM One Cable Assemblies 10 7 CTM One Wiring Diagrams 12 7.1 Wireless Operation using LCT (to control CCT, Dimming, Saturation, Hue) 7.2 0-10V Control of CCT & Dimming / LCT Control of Saturation & Hue 7.3 0-10V Control of Dimming / LCT Control of CCT, Saturation & Hue 7.4 0-10V Control of SceneSet® / LCT to Set or Amend Scenes 7.5 Digital Control Adapter (DCA) for DALI, DMX, and Lutron EcoSystem® 7.6 Digital Control Adapter (DCA) for Bluetooth 8 CTM 109, CTM 112, CTM 119 and CTM 119NR Operation Guide ii | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide 18 1 INTRODUCTION This Installation and Operation Guide covers the following araya® Color Tuning Modules (CTM): CTM 109 CTM 112 CTM 119 CTM 119NR For complete Color Tuning Module specifications, please visit: www.lumenetix.com/downloads This Installation and Operation Guide covers heat sinking, case temperature measurement, secondary optics, power supply and wiring diagrams for wireless operation using the Lumenetix Light Commissioning Tool (LCT), industry standard 0-10V wired controls or a hybrid operation that combines hard wired and wireless control. For long term reliable operation, proper heat sinking is critical. The CTM is fragile. Avoid touching the diffuser during handling and assembly. Do not rest or operate the CTM face down against a table or other solid surface. 2 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide 2 HEAT SINKING The Color Tuning Module requires an external heat sink in order to ensure proper operating temperature of the LEDs. The CTM has a conductive aluminum case and an efficient thermal path to the LED array. These features promote efficient thermal management and allow for a simple heat sink design in most applications. Examples of heat sinking methods are cast or extruded heat sinks. Both carbon and stainless steel are much less efficient at transferring heat than aluminum and therefore are not recommended as heat sink materials. The heat sink mounting surface should be flat and smooth. Metal-to-metal contact surfaces will result in best performance; anodized or unfinished mounting surfaces are recommended. Mounting the CTM on a painted aluminum surface will reduce the performance of the heat sink material. 2.1 Compatible Heat Sinks The following tables list heat sinks models that have compatible form factors and thermal resistance characteristics for use with the CTM. The thermal resistances assume an approximate ambient temperature of 25C. The heat sinks listed here are suggestions only. MechaTronix (round) Part Number Dia. (mm) Height (mm) Thermal Resistance (°C/W) LSB9950 99 50 1.3 – 1.5 LSB9980 99 80 1.2 – 1.4 Nano 7080 70 80 1.8 Micro 8630 86 30 1.8 Micro 8650 86 50 1.5 Micro 8680 86 80 1.2 IMPORTANT: These heat sinks are qualified in “free air”. If the CTM is installed in an insulated can fixture (IC Can), the module may exceed the recommended operating temperature. The heat sink must be evaluated and temperature tested in the fixture at applicable ambient temperatures for the desired application. Additional product information at www.led-heatsink.com Aavid Thermalloy Heat Sink Extrusions (square/rectangular) Part Number Width (mm) Length Height (mm) Thermal Resistance (°C/W) 67590 88 88 31 1.5 – 1.7 61085 136 85 33 1.4 – 1.6 Additional product information at www.aavid.com 3 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide 2.2 Mechanical Attachment of the Heat Sink The CTM One light engines have a Zhaga-compliant front mount option for heat sink mounting, using two 4-40 or M2.5 screws. Mechanical Specifications Dimensions 8 Diameter: 1.97 inches (50 mm) Height: 0.67 inches (17 mm); CTM 119NR: 0.84 inches (21.44 mm) Light Emitting Surface 9.5, 12.75 and 22 mm Weight 0.12 pounds (0.06kg) Heat Sink Attachment Front mount, M2.5 or 4-40 Screws Max Case Temperature <80°C 5 6 7 4 2 3 5X 2X CTM 119NR – Raised Face 5X 50 1.97 3.40 THRU .13 5 6 7 35 B.C. 1.38 50 1.97 D 1 8 CTM 119, CTM 112, CTM 109 4 35 B.C. 1.38 2X 3.40 THRU .13 USE M3X0.5 SCREW D D 3X 1.30 4 .05 USE M1.8 X4 SCREW (REFLECTOR ATTACHMENT) C Model CTM1-19 LES Diameter CTM 109 67° 37° 53° C EMITTING MODEL LIGHT SURFACE DIA C 22mm 12.75mm CTM1-12 CTM1-09 9.5 mm (0.37 inches)9mm CTM 112 12.75 mm (0.50 inches) CTM 119 22 mm (0.87 inches) .866". .502" .354" 37° 67° 53° B B B 17 .67 21.44 .84 A UNLESS OTHERWISE SPECIFIED: NAME DATE DIMENSIONS ARE IN MILLIMETERS DRAWN TOLERANCES: CHECKED ANGULAR: MACH 0.5 ONE PLACE DECIMAL 0.5 ENG APPR. TWO PLACE DECIMAL 0.15 A.N. 05/13/13 MFG APPR. A INTERPRET GEOMETRIC TOLERANCING PER: ASME Y14.5 PROPRIETARY AND CONFIDENTIAL Lumenetix UNLES TITLE: DIMEN TOLER ANGU ONE P TWO P A CTM-12V, 19 DIA, FINAL ASSEMBLY Q.A. COMMENTS: SIZE DWG. NO. REV NOTES Note: Upper dimensions areSEEin inches; lower dimensions are in millimeters. THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF LUMENETIX. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF LUMENETIX IS PROHIBITED. 8 7 6 5 MATERIAL USED ON NEXT ASSY APPLICATION 4 1 B FINISH SHEET 2 OF 2 SCALE: 1:1 WEIGHT: DO NOT SCALE DRAWING 2 3 8 Figure 1: Heat Sink Attachment Specifications 4 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide 1 7 INTERPR TOLERA PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF LUMENETIX. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF LUMENETIX IS PROHIBITED. 6 5 MATER USED ON NEXT ASSY APPLICATION 4 FINISH DO 3 POWER SUPPLY REQUIREMENTS 3.1 Electrical Specifications Description and Nominal Power Input CTM 109/112/119/119NR, 12.5W CTM 109/112/119/119NR, 20W Input Voltage 12V DC 12V DC Nominal Current Input 12.5W: 1.0A 20W: 1.7A Power Supply Classification Class 2 Class 2 IMPORTANT The Color Tuning Module has on-board drive electronics, including dimming. A dimming driver is NOT required. 3.2 Recommended Power Supplies (Constant Voltage)* Manufacturer Part Number Rated Power Input Voltage Mean Well APV-35-12 35W 90V - 264V Mean Well LPV-60-12 60W 90V - 264V Mean Well LPV-100-12 100W 90V - 264V Roal RSLP070-12 48W 120V - 277V Inventronics EUV-025S012PS 25W 120V - 277V Inventronics EUV-050S012ST 50W 120V - 277V Thomas Research LED24W-12 25W 120V - 277V Thomas Research LED50W-12 50W 120V - 277V Thomas Research PLED75W-012 75W 120V - 277V Excelsys Technologies LXV25-012SW 25W 120V - 277V Excelsys Technologies LXV50-012SW 50W 120V - 277V Excelsys Technologies LXV75-012SW 75W 120V - 277V Excelsys Technologies LXV100-012SW 100W 120V - 277V *IMPORTANT: Using a constant current power supply will damage the module, and will void the Lumenetix warranty. Using a triac or dimming driver will damage the module, and will void the Lumenetix warranty. NOTE: Recommendations are subject to change. Consult your Lumenetix representative for the most updated list. 5 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide 4 CTM ONE CASE TEMPERATURE MEASUREMENT The thermal management characteristics of the heat sink used with the CTM One should be validated by measuring its case temperature. This test should be done with the CTM One installed in the fixture at ambient temperature and air flow conditions similar to the end-use installation. The power draw of the CTM One family varies by approximately one watt over the CCT range with peak power draw occurring at the CCT shown in the following table. The case temperature should be measured at the following CCT setting. CCT Setting for Case Temperature (Tc) Measurement CCT range CCT Setting to Measure Tc 1650 – 4000K 3500K The proper case temperature measurement location is on the narrow metal band, next to the power lead port; see Figure 2. The case temperature reading should be made after the unit has reached steady state, where the case temperature levels out. It is recommended to design the thermal management system for a case temperature of 80˚C. Maximum case temperature: 80˚C The Color Tuning Module has on-board thermal protection to reduce the current to the LEDs when the maximum case temperature is exceeded. This prevents unacceptably high LED junction temperatures by slightly dimming the module. CASE TEMPERATURE MEASUREMENT POINT Figure 2: Case Temperature Measurement Point 6 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide 5 SECONDARY OPTICS 5.1 Attaching Compatible CTM One Reflectors The CTM 119NR accepts twist-to-lock reflectors with an attachment collar. The CTM 109, CTM 112 and CTM 119 have provisions for front mount reflectors and TE Type-2 clip reflectors. The fastener specifications are shown in the following table while mounting hole locations are shown in Figures 3, 4 & 5. CTM One Secondary Optics Fastener Specifications CTM One Reflector Fastener specifications Screw length Notes Twist Lock w/ Collar (CTM 119NR) Front Mount 2 - 28; M1.8 x 6 6 mm (1/4”) Thread forming; use flat head screws 2 - 28; M1.8 x 4 4 mm (1/6”) Thread forming TE Type 2 Clip M3-0.5 x 25 25 mm (1”) Machine screws; attach to heat sink (not directly to module) M1.8 x 4; 2 - 28 THREAD FORMING M1.8 x 6; 2 - 28 THREAD FORMING USE FLAT HEAD SCREWS Figure 3: CTM 119NR Twist-Lock Style Reflectors with Attachment Collars M3-0.5 x 25 MACHINE SCREW Figure 4: CTM 109 / CTM 112 / CTM 119 Front (Screw) Attaching Reflectors (by Alux-Luxar) 7 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide Figure 5: CTM 109 / CTM 112 / CTM 119 TE Type 2 Clip Reflectors (by Khatod) 5.2 Compatible Reflectors Compatible Reflectors for CTM 109 Manufacturer M. Part Number beam angle (deg) outer dim (mm) height (mm) optical finish optical finish 2 attach method khatod khatod khatod khatod Alux Luxar Alux Luxar nata nata nata nata 1682 ST 1683ST 1685 ST 1687 ST XLC 200 TLC 200 4-1406-E 3990E 3991E 3993E 20 24 32 31 22 28 20.3 23.2 35.7 40 65 65 65 65 94 85 / 94 110 75 75 85 35 35 35 35 49.5 50.5 66.2 43 43 50.5 diffuse diffuse diffuse diffuse diffuse diffuse specular specular specular specular none none none none panel faceted super faceted super faceted super faceted super faceted TE Type 2 clip TE Type 2 clip TE Type 2 clip TE Type 2 clip screw screw none none none none Compatible Reflectors for CTM 112 Manufacturer M. Part Number beam angle (deg) outer dim (mm) height (mm) optical finish optical finish 2 attach method Diffractive Optics khatod khatod khatod khatod khatod khatod khatod khatod Alux Luxar Alux Luxar Alux Luxar Alux Luxar Alux Luxar Alux Luxar Alux Luxar Alux Luxar Alux Luxar nata nata nata nata nata Top Lighting P11218 (LES12) 1682 ST 1683 ST 1684 ST 1685 ST 1687 ST 1688 ST 1690 ST 1691 ST XLC 100 XLC 200 XLC 500 TLC 500 XLC 1100 TLC 200 TLC 300 XLC 1200 TLC 900 4-1406-E 3990E 3991E 3992E 3993E XSA-15 16 20 24 28 32 31 38 50 56 18 22 25 26 27 28 46 52 54 20.3 23.2 35.7 24.8 40 60 72.6 65 65 65 65 65 65 65 65 94 94 94 85 / 92 120 85 / 94 85 / 94 120 108 / 120 110 75 75 85 85 70 33 35 35 35 35 35 35 35 35 50.3 49.5 49.5 50 65.7 50.5 50.5 65.7 66.2 66.2 43 43 50.5 50.5 43 specular diffuse diffuse diffuse diffuse diffuse diffuse diffuse diffuse specular diffuse diffuse diffuse diffuse diffuse diffuse diffuse diffuse specular specular specular specular specular specular faceted none none none none none none none none faceted panel none TE Type 2 clip TE Type 2 clip TE Type 2 clip TE Type 2 clip TE Type 2 clip TE Type 2 clip TE Type 2 clip TE Type 2 clip screw screw screw screw screw screw screw screw screw none none none none none none faceted faceted faceted faceted faceted super faceted super faceted super faceted super faceted super faceted none NOTE: Reflectors have been recommended based on independent optical tests conducted by Lumenetix, and should be used as guidelines. Final reflector evaluation should be made by fixture manufacturers with all optics in place. 8 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide Compatible Reflectors for CTM 119 and CTM 119NR Manufacturer M. Part Number beam angle (deg) outer dim (mm) height (mm) optical finish optical finish 2 attach method Widegerm Widegerm Widegerm Edison Price Edison Price Diffractive Optics Diffractive Optics Diffractive Optics Diffractive Optics Diffractive Optics khatod khatod khatod khatod khatod khatod khatod Alux Luxar Alux Luxar Alux Luxar Alux Luxar Alux Luxar Alux Luxar Alux Luxar Alux Luxar Alux Luxar Alux Luxar Alux Luxar nata nata nata Top Lighting Top Lighting Top Lighting 3207T-XC 1009T-XC 1010T-XC 770237-D20 770237-D40 P7076 (XSA-17) P7899 (XSA-22) P6764 (XSA-21) P6680 P6645 1682 CR 1682 ST 1683 ST 1685 ST 1687 ST 1688 ST 1689 ST XLC 1300 XLC 100 XLC 500 XLC 1400 XLC 1100 TLC 200 XLC 800 TLC 300 XLC 1200 TLC 900 XLC 700 4-1406-E 3991E 3993E XSA-13 XSA-14 XSA-15 38 38 55 20 40 20 40 56 40 65 11 20 24 32 31 38 42 17.6 18 25 25 27 28 42 46 52 54 32 20.3 35.7 40 22 46 60 82 49 50 70 70 94.4 49.3 50 70 70 65 65 65 65 65 65 65 120 94 94 120 120 85 / 94 94 85 / 94 120 108 / 120 94x94 110 75 85 70 70 70 46 30.4 30.4 45 45 83 28.6 29 42 42 35 35 35 35 35 35 35 65.6 50.3 49.5 65.6 65.7 50.5 49.5 50.5 65.7 66.2 50.1 66.2 43 50.5 43 43 43 diffuse specular specular specular specular specular specular specular specular specular specular diffuse diffuse diffuse diffuse diffuse diffuse diffuse specular diffuse diffuse diffuse diffuse diffuse diffuse diffuse diffuse diffuse specular specular specular specular specular specular none faceted none faceted,sq faceted, sq faceted faceted none none none none none none none none none none panel faceted twist lock* twist lock* twist lock* twist lock* twist lock* twist lock* twist lock* twist lock* twist lock* twist lock* TE Type 2 clip TE Type 2 clip TE Type 2 clip TE Type 2 clip TE Type 2 clip TE Type 2 clip TE Type 2 clip screw screw screw screw screw screw screw screw screw screw screw none none none none none none faceted faceted faceted faceted faceted faceted faceted none super faceted super faceted super faceted none none none NOTE: Reflectors have been recommended based on independent optical tests conducted by Lumenetix, and should be used as guidelines. Final reflector evaluation should be made by fixture manufacturers with all optics in place. 9 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide 6 CTM ONE CABLE ASSEMBLIES 6.1.1 Power Cable Assembly Provides power to each module. Lumenetix part #: 28.002.001.01 3 4 2 1 PIN ONE 6.35 610 Note: All dimensions are in millimeters. ITEM NO. PART NUMBER DESCRIPTION 1 874390200 MOLEX CONNECTOR 1 2 874210000 MOLEX CRIMP 2 3 A2015R-100-ND 24 AWG WIRE, RED 1 4 A2015B-100-ND 24 AWG WIRE, BLACK 1 Figure 6: Power Cable Assembly 6.1.2 Pin Allocation Chart for Power Cable Assembly Pin # Lead Color Input Pin 1 Red Power 24V DC Pin 2 Black Power GND 10 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide QTY. 6.2.1 Control Cable Assembly Provides 0-10V control and RS-485 signals to each module. Lumenetix part #: 28.002.002.01 7X STRIP AND TIN 9 8 7 6 5 4 3 2 1 8±1.50 610 10 Note: All dimensions are in millimeters. ITEM NO. PART NUMBER DESCRIPTION QTY. 1 874390700 MOLEX CONNECTOR 1 2 874210000 MOLEX CRIMP 7 3 A2015V-100-ND 24 AWG WIRE, VIOLET 1 4 A2015L-100-ND 24 AWG WIRE, BLUE 1 5 A2015A-100-ND 24 AWG WIRE, ORANGE 1 6 A2015G-100-ND 24 AWG WIRE, GREEN 1 7 A2015N-100-ND 24 AWG WIRE, BROWN 1 8 A2015S-100-ND 24 AWG WIRE, GREY (SLATE) 1 9 A2015W-100-ND 24 AWG WIRE, WHITE 1 Figure 7: Control Cable Assembly 6.2.2 Pin Allocation Chart for Control Cable Assembly Pin # Lead Color Input Pin 1 Violet 0-10V Dimming Pin 2 Blue 0-10V Color Pin 3 Orange RS-485 (A) Pin 4 Green RS-485 (B) Pin 5 Brown Digital GND Pin 6 Gray Signal GND for 0-10V Dimming Pin 7 White Signal GND for 0-10V Color 11 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide 7 CTM ONE WIRING DIAGRAMS 7.1 Wireless Operation using LCT (to control CCT, Dimming, Saturation and Hue) Wireless Operation. CTM is shipped with the wireless mode enabled as the two pairs of control wires are grounded. In this mode the Light Commissioning Tool (LCT) provides complete control of the CCT, Dimming, Saturation & Hue. LCT INPUT LCT WIRELESS INPUT DIMMING LCT WIRELESS CCT / SAT/ HUE 100% 1% CTM One CTM One + – 12V DC POWER SUPPLY + (110V/277V AC) FROM SWITCHED CONTROL Figure 8: Wireless Operation using LCT Lead Color and Input Lead Color Input Red Positive 24V Black Negative Violet Connect to Common Gray Common White Common Blue Connect to Common Lumenetix part #s: 28.002.001.01 (power cable assembly) 28.002.002.01 (control cable assembly) 12 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide 7.2 0-10V Control of Continuous CCT and Dimming / LCT Control of Saturation and Hue 0-10V Continuous CCT Control. Remove power from the CTM. Connect a 0-10V control device to the blue (+) and white (ground) wires. When the CTM is powered up, the 0-10V control will adjust the CCT over the tunable range. The Light Commissioning Tool (LCT) will control Dimming and Saturation and Hue. A 0-10V control may also be added for dimming (as shown). LCT adjustments to Dimming levels are a percentage of the 0-10V Dim setting (Trim). If a 0-10V control is not used for dimming, the gray (ground) and violet (+) wires must be grounded together. INPUT LCT WIRELESS CCT / SAT/ HUE CCT DIM INPUT LCT 10 V COMMON INPUT DIMMING COMMON Continuous CCT CTM One BLUE 0V WHITE 1% GRAY VIOLET 100% + CTM One – 12V DC POWER SUPPLY + (110V/277V AC) FROM SWITCHED CONTROL* Figure 9: 0-10V Control of Continuous CCT and Dimming Lead Color and Input Lead Color Input Red Positive 24V Black Negative Violet 0-10V Dimming Gray Common White Common Blue 0-10V CCT Notes: 1. If SceneSet® is not activated using the LCT, the CTM defaults to 0-10V control of the continuous CCT range. 2. If 0-10V control is not being used for dimming, the violet control lead must be grounded to gray common lead. 3. CTM sources current to 0-10V control at 0.2mA nominal capacity. 4. * If using a wall box dimmer, power only the DIM unit. The CCT unit does not get line-in voltage. Lumenetix part #s: 28.002.001.01 (power cable assembly) 28.002.002.01 (control cable assembly) 13 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide 7.3 0-10V Control of Dimming / LCT Control of CCT, Saturation and Hue 0-10V Dimming Control Only. Remove power from the CTM. Connect a 0-10V control device to violet (+) and gray (ground) wires. When the CTM is powered up, the 0-10V control device will adjust Dimming from 100-1%. Use the Light Commissioning Tool (LCT) to set CCT, Dimming, Saturation, and Hue to the desired levels and use Copy and Paste functions to match lamp settings. In this configuration, the LCT trims the dimming level, i.e., adjustments to Dimming levels as a percentage of the 0-10V Dimming setting (Trim). Preset controls are not available in this configuration. 0-10 V CONTROLLER LCT DIM INPUT 10 V COMMON INPUT DIMMING LCT WIRELESS CCT / SAT / HUE 0V CTM One GRAY 1% VIOLET 100% + CTM One – 12V DC POWER SUPPLY + (110V/277V AC) FROM SWITCHED CONTROL* Figure 10: 0-10V Control of Dimming Only Lead Color and Input Lead Color Input Red Positive 24V Black Negative Violet 0-10V Dimming Gray Common 1. C TM sources current to 0-10V control at 0.2mA nominal capacity. White Common 2. Only pins 1 and 6 are used. Blue Connect to Common Lumenetix part #s: 28.002.001.01 (power cable assembly) 28.002.002.01 (control cable assembly) Notes: 3. *If using a wall box dimmer, power only the DIM unit. The CCT unit does not get line-in voltage. 14 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide 7.4 0-10V Control of SceneSet® / LCT to Set or Amend SceneSet® 0-10V Preset Control. Remove power from the CTM. Connect a 0-10V control device to the blue (+) and white (ground) wires. Use the Light Commissioning Tool (LCT) to set, store and enable up to five preset scenes comprised of CCT, Dimming and Saturation & Hue levels. The 0-10V control will toggle between the preset scenes. A 0-10V control may also be added for dimming (as shown) and will proportionally Dim from the stored value in the preset. If a 0-10V control is not used for dimming, the gray (ground) and violet (+) wire must be grounded together. CCT DIM INPUT LCT 10 V COMMON INPUT COMMON DIMMING SCENESET® 100% SCENE 5 SCENE 4 CTM One SCENE 2 BLUE 0V WHITE 1% GRAY VIOLET SCENE 3 SCENE 1 + CTM One – 12V DC POWER SUPPLY + (110V/277V AC) FROM SWITCHED CONTROL* Figure 11: 0-10V SceneSet® Control Lead Color and Input Lead Color Input Red Positive 24V Black Negative Violet 0-10V Dimming Gray Common White Common Blue 0-10V Presets Notes: 1. SceneSet® is commissioned and activated using the LCT. See LCT operating instructions. 2. If 0-10V control is not being used for dimming, the violet control lead must be grounded to gray common lead. 3. CTM sources current to 0-10V control at 0.2mA nominal capacity. 4. * If using a wall box dimmer, power only the DIM unit. The CCT unit does not get line-in voltage. Lumenetix part #s: 28.002.001.01 (power cable assembly) 28.002.002.01 (control cable assembly) 15 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide 7.5 Digital Control Adapter (DCA) for DALI, DMX, and Lutron Ecosystem® Notes: 1. Ground from external adapter (brown) does not need to be connected if the araya® module and the Digital Control Adapter use a common power supply.* *Depending on the application, wiring may be connected through but left unconnected in the junction box. 2. Maximum of 30 luminaires in Parallel/Star with two 120Ω terminators at end of run; max distance of 900 feet. Every luminaire consumes “DMX” energy. A maximum of 30 devices can be connected to one DMX line. After this, the signal needs to be boosted with a DMX-Booster. The “4 way optosplitter” splits and boosts the DMX signal. For DMX inputs: Black wire is Ground Violet is Data Positive Gray is Data Negative Brown Orange Green EcoSystem® or DALI 4. A dapter is configured at factory for EcoSystem®, DALI, DMX or Bluetooth inputs. 5. Module Data +/- (green/orange) to araya® modules is class 2 rated. 6. Control Field Wiring: Liberty cable 24-2P-485 Non-Plenum 24-2P-P485 Plenum DMX Black Violet Gray 3. 12V power (red/black) is class 2 rated. PN: 28.020.001.01 Belden cable 9842 Non-Plenum 89842 Plenum Please refer to wire manufacturer’s lighting catalog for and/equals as required by code. 7. C AUTION: The power cable should ONLY be plugged into the 2-pin power receptacle provided. Insertion of the cable into any other slot will damage the Digital Control Adapter unit. Digital Control Adapter PN: 28.002.001.01 PN: 28.020.002.01 Locate at Control System + – Black CTM One Red PN: 28.002.002.03 12V DC, Class 2 AC to DC Power Supply Black White PN: 28.002.002.01 Line in Voltage (110V/277V AC) From Switched Control CTM One + – Black Hot Red Neutral (FIXTURE 1) PN: 28.002.002.01 Black White 12V DC, Class 2 AC to DC Power Supply Line in Voltage (110V/277V AC) From Switched Control Neutral (FIXTURE 2) Figure 12: DCA for DALI, DMX, and Lutron Ecosystem® 16 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide Hot 7.6 Digital Control Adapter (DCA) for Bluetooth Notes: 1. G round from external adapter (brown) does not need to be connected if the araya® module and the Digital Control Adapter use a common power supply.* *Depending on the application, wiring may be connected through but left unconnected in the junction box. 2. Maximum of 30 luminaires in Parallel/Star with two 120Ω terminators at end of run; max distance of 900 feet. Every luminaire consumes “DMX” energy. A maximum of 30 devices can be connected to one DMX line. After this, the signal needs to be boosted with a DMX-Booster. The “4 way optosplitter” splits and boosts the DMX signal. 4. A dapter is configured at factory for EcoSystem®, DALI, DMX or Bluetooth inputs. NOT USED 5. M odule Data +/- (green/orange) to araya® modules is class 2 rated. 6. Control Field Wiring: Liberty cable 24-2P-485 Non-Plenum 24-2P-P485 Plenum Brown Orange Green 3. 12V power (red/black) is class 2 rated. NOT USED Belden cable 9842 Non-Plenum 89842 Plenum Please refer to wire manufacturer’s lighting catalog for and/equals as required by code. 7. C AUTION: The power cable should ONLY be plugged into the 2-pin power receptacle provided. Insertion of the cable into any other slot will damage the Digital Control Adapter unit. Digital Control Adapter PN: 28.002.001.01 PN: 28.020.002.01 Locate at Control System + – Black CTM One Red PN: 28.002.002.03 12V DC, Class 2 AC to DC Power Supply Black White PN: 28.002.002.01 Line in Voltage (110V/277V AC) From Switched Control CTM One + – Black Hot Red Neutral (FIXTURE 1) PN: 28.002.002.01 Black White 12V DC, Class 2 AC to DC Power Supply Line in Voltage (110V/277V AC) From Switched Control Neutral (FIXTURE 2) Figure 13: DCA for Bluetooth 17 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide Hot 8 CTM ONE OPERATION GUIDE The araya® Color Tuning Modules CTM 109, CTM 112, CTM 119 and CTM 119NR utilize standard 0-10V building controls and/or a wireless Light Commissioning Tool (LCT) for controlling on-Planckian correlated color temperatures (CCT), dimming values, off-Planckian color points (color tinting) using the Saturation & Hue feature, and commissioning and activating SceneSet®. This document describes how to control the CTM utilizing 0-10V controls, the wireless remote or a combination of the two. Light Commissioning Tool (LCT). The araya® LCT \wirelessly controls the CTM. While the LCT can act as a stand-alone wireless controller, it is primarily intended to commission the CTM after installation. Each CTM has a unique address and the operator uses the LCT to select the desired CTM, turn power on/off and then set CCT, Dim, Saturation & Hue, and set Scene Presets. The LCT can also be used to trim the dimming levels when 0-10V dimming control is enabled. Consult the LCT Operation Guide for detailed instructions. 0-10V Control. The CTM has 0-10V control wire pairs to control Dimming and CCT. Dimming is controlled by the violet (+) and grey (ground) wires. CCT is controlled by the blue (+) and white (ground) wires. When a control wire pair is grounded together, the 0-10V control mode is disabled, and the corresponding function is controlled via the LCT. Hybrid (wired & wireless) Control. 0-10V controls and the LCT can be used together to control the CTM. These are the features: Trim. When 0-10V Dimming is enabled, the LCT can adjust the dimming level as a percentage of the 0-10V wired setting. SceneSet®. The LCT can set up to 5 Scene Presets which are recalled using a wired 0-10V controller. A scene is comprised of a CCT, Dim and Saturation & Hue level. Individual preset scenes also can be modified and activated with the LCT . On-Off Control. The CTM may be turned on-off by switching the input power from the 12V supply. To store the settings, the lamp needs to remain on for at least 45 seconds after the CTM is initially set using the LCT. When Scene Presets are activated using the LCT, the settings are stored immediately and no wait time is needed. The lamp may also be turned on-off using the LCT without switching the power supply, but a power draw of about 1W will remain. 18 | araya® CTM 109, CTM 112, CTM 119 and CTM 119NR Installation and Operation Guide Lumenetix Inc. 4742 Scotts Valley Drive Scotts Valley, CA 95066 877.805.7284 www.lumenetix.com Revised 06.29.15 Specifications subject to change without notice