Low Surface Temperature Collection

Transcription

Low Surface Temperature Collection
Safety Series
Low Surface
Temperature
Collection
16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:34 Page 36
LST Range
Standard
Stelrad’s range of Low Surface Temperature
radiators is the most comprehensive in
the UK, with sizes and models to suit
all applications. They all meet NHS
Guidance for ‘safe hot water and surface
temperature’ and are finished with antibacterial paint as standard, making
them the No.1 choice for safety-critical
environments. Installation is simple
and all components are included in
a single robust pack.
Standard 72 models
Heights: 500mm, 600mm & 800mm
CPD
BIM
Lengths: 560mm to 1960mm
Outputs: 196 to 2767 watts, 668 to 9442 Btu/hr
Types:
K1, P+ & K2
16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:34 Page 37
LST Range
Plus Vertical
Plus Vertical 3 models
Height:
2110mm
Lengths: 560mm, 660mm & 760mm
Outputs: 1335 to 1862 watts, 4555 to 6353 Btu/hr
Type:
K2
CPD
BIM
16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:34 Page 39
LST Range
i Plus
i Plus 72 models
Heights: 500mm, 650mm & 800mm
Lengths: 650mm to 2050mm
Outputs: 196 to 2767 watts, 669 to 9441 Btu/hr
Types:
K1, P+ & K2
CPD
BIM
16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:35 Page 127
Safety
Stelrad has created a range of Low Surface Temperature
radiators which provide the perfect solution for all
specification requirements in safety critical environments.
The complete choice
Stelrad LST range offers you the flexibility you need
The first coat of paint is applied by electrophoresis
and the radiator is then stoved and cooled
• The LST Standard leaves you free to specify your
preferred controls
• Followed by a second powder coat in warm white,
the emitter then goes through a final curing stage.
It is then allowed to cool prior to packaging
• The LST Plus and LST i Plus offer an integral remote
sensing thermostat valve, the highly specified Danfoss
RAS-D Remote Sensor
• All exposed painted surfaces are finished in a long
lasting anti-bacterial coating
• The LST Vertical is ideal where space is at a premium
LST i Plus
• An arthritic adaptor is supplied as standard for less able
environments - along with a lockshield valve which can
only be adjusted with a 6mm Allen key, hidden with a
neat metal dust cover to discourage unauthorised
tampering. (excludes LST Standard)
Remote sensing thermostatic valve
The complete package
• Special tools are not required, as the valve is gland
seal removable
• Every Stelrad LST radiator is supplied with an
attractive, flat panel outer casing, which is totally
reversible to allow piping flexibility
• Simple and quick to install, the casing is held by
security fittings with a unique seam fixing bracket
system to prevent unauthorised access to the
emitter accommodated inside
• For added protection, the smooth surface
is coated in anti-bacterial paint
• The emitter provides high outputs through
convection for outstanding heating performance
• Controlled independent laboratory testing ensures
that each emitter is guaranteed to perform to a
maximum working pressure of 116 psi (8 bar)
and conform to BS EN 442, the European
Standard for radiators
• The Danfoss RAS-D Remote Sensor is designed
specifically for commercial heating systems and can
be pre-set to allow adjustment of room temperature
between 5°C and 26°C
• Suitable for both 1⁄2" steel and 15mm copper piping,
with left or right hand, same end connections for flow
and return, gives flexibility of installation
Lockshield valve
• Able to withstand 10 bar static pressure, the valve
has a drain tap adaptor available, which can also
be used as a filling point
• Mandatory fittings should be used in order to comply
with current water regulations
Connections
• 2 x 1⁄2" connections as standard, complete with Danfoss
remote sensing thermostatic radiator valve, pre-piped
with 2 x 1⁄2" BSP connections at 50mm centres
positioned at either left or right of the casing
• All specified components required supplied
in one robust package
Anti-bacterial paint
• Every LST emitter is subjected to a multi-stage
cleaning process before the paint is applied. This
involves several rinsing stages, including an iron
phosphate and demineralisation phase
CP
BIM
For further information and
advice call 0844 543 6200
16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:35 Page 128
LST Standard, LST i Plus
& LST Vertical temperature table
For systems not operating at ∆t50 the factors in the table
below should be applied. The output of a given radiator
can be obtained by multiplying the quoted ∆t50 output
by the operating factor. Conversely, to derive a non ∆t50
output, divide the heat output required by the relevant
operation factor. This ‘∆t50 equivalent output’ can then
be used to select a radiator from the standard tables.
∆t
°C
Operating Factor
∆t
°F
Operating Factor
5
0.050
10
0.057
10
0.123
20
0.142
15
0.209
30
0.240
20
0.304
40
0.348
25
0.406
50
0.466
30
0.515
60
0.590
35
0.629
70
0.721
40
0.748
80
0.858
45
0.872
90
1.000
50
1.000
100
1.147
55
1.132
110
1.298
60
1.267
120
1.454
65
1.406
130
1.613
70
1.549
150
1.776
75
1.694
-
-
Example: Exact output at ∆t50 = 2000 Btu/hr
Output at ∆t30 = 2000 x 0.515 = 1030 Btu/hr
Average coefficient of 130 is used in the example above
Testing and operating pressures
All models are high pressure tested to withstand 152.3
psi (10.5 bar). Strictly controlled independent laboratory
testing ensures that all Stelrad radiators are guaranteed
to perform to a maximum working pressure of 116 psi
(8 bar) at a maximum temperature of 95°C. All conform
to BS EN 442 - the European Standard for radiators.
Caution
To ensure that the emitter complies with all aspects
of the NHS guidance for “Safe hot water and surface
temperature”, Stelrad recommends that a maximum
flow temperature of 80° be used with a 20° drop
across the system.
When designing for domestic systems we recommend
that the Stelrad LST range be used only in heating
systems complying with the British Standard Code
of Practice for Central Heating for Domestic Premises
BS EN 12828:2003 and BS EN 12831:2003.
Single feed, indirect cylinders are not recommended as
should interchange of water occur, fresh aerated water
would enter the heating system, resulting in corrosion.
Water treatment
On completion of the installation, the system should
be properly flushed and filled in accordance with the
British Standard Code of Practice BS 7593:2006 for
the Treatment of Water in Domestic Hot Water Central
Heating Systems, Part L of Building Regulations
and Good Practice Guidance for Scotland.
After installation of a new Stelrad radiator the central
heating system should be cleaned and flushed with
cleaner to remove existing contaminants, flux residue
and other installation debris which, if left, can cause
damage to the new radiator. Afterwards, treat the
system with an inhibitor to ensure long term protection
against corrosion and limescale.
A comprehensive range of quality chemicals including
inhibitors, cleaners, leak sealers and noise reducers that
protect and maintain central heating systems can be
obtained from:
Sentinel Performance Solutions Ltd
The Heath Business & Technical Park, Runcorn,
Cheshire WA7 4QX
Tel: 01928 588 330 (UK) www.sentinel-solutions.net
Fernox - Cookson Electronics,
Forsyth Road, Sheerwater, Woking, Surrey
GU21 5RZ www.fernox.com
Pressure drops
16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:35 Page 129
Stelrad LST Range Standard
K1
50 Δt (75/65/20°C)
Casing Height
500
650
800
Casing
Length mm
Emitter
Height mm
Emitter
Length mm
UIN
560
760
960
1160
1360
1560
1760
1960
560
760
960
1160
1360
1560
1760
1960
560
760
960
1160
1360
1560
1760
1960
300
300
300
300
300
300
300
300
450
450
450
450
450
450
450
450
600
600
600
600
600
600
600
600
400
600
800
1000
1200
1400
1600
1800
400
600
800
1000
1200
1400
1600
1800
400
600
800
1000
1200
1400
1600
1800
145000
145001
145002
145003
145004
145005
145006
145007
145024
145025
145026
145027
145028
145029
145030
145031
145048
145049
145050
145051
145052
145053
145054
145055
P+
Heat output
Watts Btu/hr
1
196
293
391
489
587
685
782
880
290
435
580
725
870
1015
1160
1305
365
548
730
913
1096
1278
1461
1643
145008
145009
145010
145011
145012
145013
145014
145015
145032
145033
145034
145035
145036
145037
145038
145039
145056
145057
145058
145059
145060
145061
145062
145063
669
1000
1334
1668
2003
2337
2668
3003
989
1484
1979
2474
2968
3463
3958
4453
1245
1870
2493
3115
3740
4361
4985
5606
UIN
K2
Heat output
Watts Btu/hr
284
426
568
710
852
994
1136
1278
386
580
773
966
1159
1352
1546
1739
501
751
1002
1252
1502
1753
2003
2254
969
1454
1938
2423
2907
3392
3876
4361
1317
1979
2637
3296
3955
4613
5275
5933
1709
2562
3419
4272
5125
5981
6837
7691
UIN
145016
145017
145018
145019
145020
145021
145022
145023
145040
145041
145042
145043
145044
145045
145046
145047
145064
145065
145066
145067
145068
145069
145070
145071
Heat output
Watts Btu/hr
348
522
696
870
1044
1218
1392
1566
478
717
956
1195
1434
1673
1912
2151
615
922
1230
1537
1844
2152
2459
2767
1187
1781
2375
2968
3562
4156
4750
5343
1631
2446
3262
4077
4893
5708
6524
7341
2098
3146
4197
5244
6295
7343
8393
9441
∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have
a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer).
K1
40 Δt (65/55/20°C)
Casing Height
500
650
800
Casing
Length mm
Emitter
Height mm
Emitter
Length mm
560
760
960
1160
1360
1560
1760
1960
560
760
960
1160
1360
1560
1760
1960
560
760
960
1160
1360
1560
1760
1960
300
300
300
300
300
300
300
300
450
450
450
450
450
450
450
450
600
600
600
600
600
600
600
600
400
600
800
1000
1200
1400
1600
1800
400
600
800
1000
1200
1400
1600
1800
400
600
800
1000
1200
1400
1600
1800
UIN
P+
Heat output
Watts Btu/hr
145000 147
145001 219
145002 292
1
145003 366
145004 439
145005 512
145006 585
145007 658
145024 217
145025 325
145026 434
145027 542
145028 651
145029 759
145030 868
145031 976
145048 273
145049 410
145050 546
145051 683
145052 820
145053 956
145054 1093
145055 1229
500
748
998
1248
1498
1748
1996
2246
740
1110
1480
1850
2220
2590
2961
3331
932
1399
1863
2330
2797
3262
3729
4193
UIN
145008
145009
145010
145011
145012
145013
145014
145015
145032
145033
145034
145035
145036
145037
145038
145039
145056
145057
145058
145059
145060
145061
145062
145063
K2
Heat output
Watts Btu/hr
212
319
425
531
637
744
850
956
289
434
578
723
867
1011
1156
1301
375
562
749
936
1123
1311
1498
1686
725
1087
1450
1812
2174
2537
2899
3262
985
1480
1973
2465
2958
3451
3946
4438
1279
1917
2557
3195
3833
4474
5112
5753
UIN
145016
145017
145018
1
145019
145020
145021
145022
145023
145040
145041
145042
145043
145044
145045
145046
145047
145064
145065
145066
145067
145068
145069
145070
145071
Heat output
Watts Btu/hr
260
390
521
651
781
911
1041
1171
358
536
715
894
1073
1251
1430
1609
460
690
920
1150
1379
1610
1839
2070
888
1332
1776
2220
2664
3109
3553
3997
1220
1830
2440
3050
3660
4270
4880
5490
1570
2353
3139
3923
4706
5492
6276
7062
16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:36 Page 130
Stelrad LST Range Standard
K1
30 Δt (55/45/20°C)
Casing Height
500
650
800
Casing
Length mm
Emitter
Height mm
Emitter
Length mm
UIN
560
760
960
1160
1360
1560
1760
1960
560
760
960
1160
1360
1560
1760
1960
560
760
960
1160
1360
1560
1760
1960
300
300
300
300
300
300
300
300
450
450
450
450
450
450
450
450
600
600
600
600
600
600
600
600
400
600
800
1000
1200
1400
1600
1800
400
600
800
1000
1200
1400
1600
1800
400
600
800
1000
1200
1400
1600
1800
145200
145201
145202
145203
145204
145205
145206
145207
145208
145209
145210
145211
145212
145213
145214
145215
145216
145217
145218
145219
145220
145221
145222
145223
P+
Heat output
Watts Btu/hr
101
151
201
252
302
353
403
453
149
224
299
373
448
523
597
672
188
282
376
470
564
658
752
846
344
515
687
859
1031
1204
1374
1546
510
764
1019
1274
1529
1784
2038
2293
641
963
1283
1604
1926
2246
2567
2887
UIN
K2
Heat output
Watts Btu/hr
145248 146
145249 219
145250 293
145251 366
145252 439
145253 512
145254 585
145255 658
145256 199
145257 299
145258 398
145259 497
145260 597
145261 696
145262 796
145263 896
145264 258
145265 387
145266 516
145267 645
145268 774
145269 903
145270 1032
145271 1161
499
749
998
1248
1497
1747
1996
2246
678
1019
1358
1697
2037
2376
2717
3056
880
1320
1761
2200
2639
3080
3520
3961
Heat output
Watts Btu/hr
UIN
145224
145225
145226
145227
145228
145229
145230
145231
145232
145233
145234
145235
145236
145237
145238
145239
145240
145241
145242
145243
145244
145245
145246
145247
179
269
358
448
538
627
717
806
246
369
492
615
739
862
985
1108
317
475
633
792
950
1108
1266
1425
611
917
1223
1529
1834
2140
2446
2752
840
1260
1680
2100
2520
2940
3360
3780
1081
1620
2161
2701
3240
3781
4321
4862
EN 442 Certification Data - CETIAT tested in accordance with BS EN 442
Type
Casing Height
Emitter Height
W/m at 75/65/20
n-coefficients
Heated Surface Area (m²/m)
Weight (kg/m)
Water Contents (l/m)
K1
500
300
489
1.19
2.09
17.80
1.89
650
450
725
1.25
3.37
23.50
2.57
P+
800
600
913
1.34
4.66
29.40
3.25
500
300
710
1.24
2.44
22.70
3.70
650
450
966
1.27
3.84
30.72
5.15
K2
800
600
1252
1.31
5.24
38.40
6.60
500
300
870
1.27
3.51
24.40
3.70
650
450
1195
1.30
5.62
33.30
5.15
800
600
1537
1.32
7.74
42.50
6.60
16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:36 Page 131
LST Standard wall fixings & bracket positions
All dimensions in mm. Inches in brackets.
195 (7.67)
134
(5.27)
102 (4.01)
100 (3.93)
Casing
Height
500
650
800
Casing Height
Casing
Length
560
760
960
24 (0.94)
195 (7.67)
165 (6.49)
165 (6.49)
Casing Length
Casing
Height
500
650
800
24 (0.94)
134
(5.27)
B
475
575
675
775
875
195 (7.67)
102 (4.01)
A
445
545
645
745
845
Casing Height
Casing
Length
1160
1360
1560
1760
1960
A
100 (3.93)
195 (7.67)
165 (6.49)
165 (6.49)
B
Casing Length
16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:36 Page 132
LST Standard connection options
All dimensions in mm. Inches in brackets.
119
(4.68)
25 (0.98)
A
250
400
550
A
Casing
Height
500
650
800
Casing Height
132 (5.19)
LST Standard piping options
16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:36 Page 133
Stelrad LST Range Plus Vertical
50 Δt (75/65/20°C)
Casing Height
Casing
Length mm
Emitter
Height mm
Emitter
Length mm
UIN
2110
560
660
760
1800
1800
1800
400
500
600
142241
142242
142243
Heat output
Watts Btu/hr
1271
1588
1855
4336
5418
6329
∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have
a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer).
W
LST Plus Vertical installation instructions
All dimensions in mm. Inches in brackets.
Present casing and bottom bracket to the wall and mark drill hole positions.
Fit pipework and valve connections to the radiators.
560, 660, or 760
195 (7.68)
195 (7.68)
radiator indentation left
Looking to the front
of the radiator
radiator indentation right
2086.5 (82.15)
Looking to the front
of the radiator
L
R
indentation
1544 (60.79)
2x
Bottom view
257 (10.12)
459 (18.07)
404 (15.91)
17.5 (0.69)
359 (14.13)
165 (6.50)
16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:36 Page 134
LST Plus Vertical connection options
All dimensions in mm. Inches in brackets.
132 (5.19)
radiator indentation left
Looking to the front
of the radiator
radiator indentation right
Looking to the front
of the radiator
243 (9.56)
indentation
Casing
Length A
560
344
660
444
760
544
50
(1.96)
A
Casing length
Bottom view
16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:36 Page 141
Stelrad LST Range i Plus
K1
50 Δt (75/65/20°C)
Casing Height
500
650
800
Casing
Length mm
Emitter
Height mm
Emitter
Length mm
UIN
650
850
1050
1250
1450
1650
1850
2050
650
850
1050
1250
1450
1650
1850
2050
650
850
1050
1250
1450
1650
1850
2050
300
300
300
300
300
300
300
300
450
450
450
450
450
450
450
450
600
600
600
600
600
600
600
600
400
600
800
1000
1200
1400
1600
1800
400
600
800
1000
1200
1400
1600
1800
400
600
800
1000
1200
1400
1600
1800
145200
145201
145202
145203
145204
145205
145206
145207
145208
145209
145210
145211
145212
145213
145214
145215
145216
145217
145218
145219
145220
145221
145222
145223
P+
Heat output
Watts Btu/hr
1
196
293
391
489
587
685
782
880
290
435
580
725
870
1015
1160
1305
365
548
730
913
1096
1278
1461
1643
145248
145249
145250
145251
145252
145253
145254
145255
145256
145257
145258
145259
145260
145261
145262
145263
145264
145265
145266
145267
145268
145269
145270
145271
669
1000
1334
1668
2003
2337
2668
3003
989
1484
1979
2474
2968
3463
3958
4453
1245
1870
2493
3115
3740
4361
4985
5606
UIN
K2
Heat output
Watts Btu/hr
284
426
568
710
852
994
1136
1278
386
580
773
966
1159
1352
1546
1739
501
751
1002
1252
1502
1753
2003
2254
969
1454
1938
2423
2907
3392
3876
4361
1317
1979
2637
3296
3955
4613
5275
5933
1709
2562
3419
4272
5125
5981
6837
7691
UIN
145224
145225
145226
145227
145228
145229
145230
145231
145232
145233
145234
145235
145236
145237
145238
145239
145240
145241
145242
145243
145244
145245
145246
145247
Heat output
Watts Btu/hr
348
522
696
870
1044
1218
1392
1566
478
717
956
1195
1434
1673
1912
2151
615
922
1230
1537
1844
2152
2459
2767
1187
1781
2375
2968
3562
4156
4750
5343
1631
2446
3262
4077
4893
5708
6524
7341
2098
3146
4197
5244
6295
7343
8393
9441
∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have
a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer).
K1
40 Δt (55/45/20°C)
Casing Height
500
650
800
Casing
Length mm
Emitter
Height mm
Emitter
Length mm
650
850
1050
1250
1450
1650
1850
2050
650
850
1050
1250
1450
1650
1850
2050
650
850
1050
1250
1450
1650
1850
2050
300
300
300
300
300
300
300
300
450
450
450
450
450
450
450
450
600
600
600
600
600
600
600
600
400
600
800
1000
1200
1400
1600
1800
400
600
800
1000
1200
1400
1600
1800
400
600
800
1000
1200
1400
1600
1800
UIN
P+
Heat output
Watts Btu/hr
145200 147
145201 219
145202 292
145203 366
145204 439
145205 512
145206 585
145207 658
145208 217
145209 325
145210 434
145211 542
145212 651
145213 759
145214 868
145215 976
145216 273
145217 410
145218 546
145219 683
145220 820
145221 956
145222 1093
145223 1229
500
748
998
1248
1498
1748
1996
2246
740
1110
1480
1850
2220
2590
2961
3331
932
1399
1863
2330
2797
3262
3729
4193
UIN
145248
145249
145250
145251
145252
145253
145254
145255
145256
145257
145258
145259
145260
145261
145262
145263
145264
145265
145266
145267
145268
145269
145270
145271
K2
Heat output
Watts Btu/hr
212
319
425
531
637
744
850
956
289
434
578
723
867
1011
1156
1301
375
562
749
936
1123
1311
1498
1686
725
1087
1450
1812
2174
2537
2899
3262
985
1480
1973
2465
2958
3451
3946
4438
1279
1917
2557
3195
3833
4474
5112
5753
UIN
145224
145225
145226
145227
145228
145229
145230
145231
145232
145233
145234
145235
145236
145237
145238
145239
145240
145241
145242
145243
145244
145245
145246
145247
Heat output
Watts Btu/hr
260
390
521
651
781
911
1041
1171
358
536
715
894
1073
1251
1430
1609
460
690
920
1150
1379
1610
1839
2070
888
Btu/hr
1332
1776
2220
2664
3109
3553
3997
1220
1830
2440
3050
3660
4270
4880
5490
1570
2353
3139
3923
4706
5492
6276
7062
16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:36 Page 142
Stelrad LST Range i Plus
K1
30 Δt (55/45/20°C)
Casing Height
500
650
800
Casing
Length mm
Emitter
Height mm
Emitter
Length mm
UIN
650
850
1050
1250
1450
1650
1850
2050
650
850
1050
1250
1450
1650
1850
2050
650
850
1050
1250
1450
1650
1850
2050
300
300
300
300
300
300
300
300
450
450
450
450
450
450
450
450
600
600
600
600
600
600
600
600
400
600
800
1000
1200
1400
1600
1800
400
600
800
1000
1200
1400
1600
1800
400
600
800
1000
1200
1400
1600
1800
145200
145201
145202
145203
145204
145205
145206
145207
145208
145209
145210
145211
145212
145213
145214
145215
145216
145217
145218
145219
145220
145221
145222
145223
P+
Heat output
Watts Btu/hr
101
151
201
252
302
353
403
453
149
224
299
373
448
523
597
672
188
282
376
470
564
658
752
846
344
515
687
859
1031
1204
1374
1546
510
764
1019
1274
1529
1784
2038
2293
641
963
1283
1604
1926
2246
2567
2887
UIN
K2
Heat output
Watts Btu/hr
145248 146
145249 219
145250 293
145251 366
145252 439
145253 512
145254 585
145255 658
145256 199
145257 299
145258 398
145259 497
145260 597
145261 696
145262 796
145263 896
145264 258
145265 387
145266 516
145267 645
145268 774
145269 903
145270 1032
145271 1161
499
749
998
1248
1497
1747
1996
2246
678
1019
1358
1697
2037
2376
2717
3056
880
1320
1761
2200
2639
3080
3520
3961
Heat output
Watts Btu/hr
UIN
145224
145225
145226
145227
145228
145229
145230
145231
145232
145233
145234
145235
145236
145237
145238
145239
145240
145241
145242
145243
145244
145245
145246
145247
179
269
358
448
538
627
717
806
246
369
492
615
739
862
985
1108
317
475
633
792
950
1108
1266
1425
611
917
1223
1529
1834
2140
2446
2752
840
1260
1680
2100
2520
2940
3360
3780
1081
1620
2161
2701
3240
3781
4321
4862
EN 442 Certification Data - CETIAT tested in accordance with BS EN442
Type
Casing Height
Emitter Height
W/m at 75/65/20
n-coefficients
Heated Surface Area (m²/m)
Weight (kg/m)
Water Contents (l/m)
K1
500
300
489
1.19
2.09
17.80
1.89
650
450
725
1.25
3.37
23.50
2.57
P+
800
600
913
1.34
4.66
29.40
3.25
500
300
710
1.24
2.44
22.70
3.70
650
450
966
1.27
3.84
30.72
5.15
K2
800
600
1252
1.31
5.24
38.40
6.60
500
300
870
1.27
3.51
24.40
3.70
650
450
1195
1.30
5.62
33.30
5.15
800
600
1537
1.32
7.74
42.50
6.60
16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:36 Page 143
LST i Plus wall fixings and bracket positions
134 (5.27)
100 (3.93)
Casing
Height
500
650
800
270 (10.63)
102 (4.01)
Casing
Length
650
850
1050
Casing Height
270 (10.63)
24 (0.94)
All dimensions in mm. Inches in brackets.
237 (9.33)
237 (9.33)
Casing Length
24 (0.94)
Casing
Height
500
650
800
134 (5.27)
B
448
548
648
748
848
100 (3.93)
A
415
515
615
715
815
Casing Height
Casing
Length
1250
1450
1650
1850
2050
270 (10.63)
A
102 (4.01)
270 (10.63)
237 (9.33)
B
237 (9.33)
Casing Length
16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:36 Page 144
LST i Plus connection options
All dimensions in mm. Inches in brackets.
25 (0.98)
A
Casing Height
87 (3.42)
Casing
Height A
500
250
650
400
800
550
35 (1.37)
60 (2.36)
50 (1.96)
87 (3.42)
Control on left-hand side
35 (1.37)
50 (1.96)
Pipe configurations
120 (4.72)
132 (5.19)
Control on right-hand side
16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:36 Page 145
LST Range Components
LST Standard front case view.
LST Standard inside the
casing showing the
emitter.
LST Standard emitter,
showing high level valve
option (valve not included).
LST Standard circular
knockout for TRV. Oblong
knockout for pipe.
LST Plus inside the casing
showing the emitter.
LST Vertical front case view.
LST i Plus front case view.
LST i Plus inside the casing
showing the emitter.
LST Plus front case view.
LST Plus and LST i Plus Components
Optional cover cap to
discourage unauthorised
tampering.
An arthritic adaptor is
supplied as standard
for special needs
environments.
Accommodated within the
casing, the Stelrad LST Plus
emitter, with TBSE valve
arrangement and 2 x 1⁄2"
BSP connections as
standard.
Connection arrangement
bottom.
Connection arrangement top.
The Stelrad STARS Heatloss Calculator
contains an inbuilt U value calculator.
Save time and effort by using the
Stelrad STARS program - the perfect
solution for accurate sizing and
design flexibility.
www.starsapp.co.uk
Includes Danfoss RA-2000
TRV and copper pipe
configuration.
The remote sensing
thermostatic valve gives
accuracy of operation
and the limiting device is
completely hidden to
prevent the maximum
temperature being
exceeded.
Safety Series
Stelrad House
Marriot Road
Mexborough
Rotherham
S64 8BN
www.stelrad.com
info@stelrad.com
01709 578 950
Merchant Enquiries Telephone