50At - Stelrad
Transcription
50At - Stelrad
The Radiator Book There’s so much more to Stelrad There’s so much more to Stelrad quality established classic best sellers reliable great value flexibility creativity ™ radical modern newcomers innovative energy saving availability You probably know that Stelrad is the brand behind the UK’s best selling and most popular radiator ranges. With nationwide availability from stock, models to perfectly suit any domestic or commercial application and a reputation for reliability and service. But now we’d like to introduce you to some of the other ideas and innovations we’ve introduced - with great new designs, styles and technological advances, making Stelrad even more of a flexible choice for you. Think radiators, think Stelrad every time. There’s so much more to Stelrad Contents Best Sellers Designer Energy Saving Safety Technical Information Technical Information Elite 6 44-48 Compact Range 7-9 49-56 STR 10 57-58 Towel Rail Range 11 59-60 Caliente Towel Rail Range 12-13 61-62 Concord Towel Rail 14 63 Esprit 15 64-65 Softline 16 66-70 Compact with Style Range 18-19 73-79 Planar Range 20-21 80-86 Concord Range 22-23 87-95 Classic Column Range 24-25 96-99 Swing 26 100-101 Caliente 27 102-104 Excel 28 105 Arc 29 106 Wave 29 106 Vistaline 30 107 Ellipse 31 108 Optia 32 109 Radical 34 110-126 LST Standard 36 129-132 LST Plus Vertical 37 133-134 LST Plus 38 135-140 LST i Plus 39 141-144 LST Range Components 145 Introduction 40-41 Accessories 42 Best Sellers 43-70 Designer 71-109 Energy Saving 110-126 Safety 127-145 Colour Options 146-147 Glossary 148 Product Summary 151 best sellers Stelrad radiators are the ‘go to’ choice for almost every application. With hundreds of models and sizes to select from, and instant availability from stock nationwide, Stelrad has become the best selling choice for fitters and specifiers reliable, efficient, easy to install and providing a great heating performance. A choice of functional but stylish towel rails, and the elegant contours of our Softline radiators, complement the ever popular Compact and Elite ranges. Elite Best Sellers Outstanding choice, versatility, quality and performance make Stelrad Elite the UK’s most popular radiator - the perfect solution when maximum heat output is needed from a steel panel radiator. The Elite range is readily available nationwide. 183 models Heights: 300mm to 700mm Lengths: 400mm to 3000mm BIM Outputs: 190 to 6033 watts, 650 to 20585 Btu/hr Types: P1, K1, P+ & K2 For full details please refer to pages 44-48 6 Compact Range Horizontal Best Sellers The Compact is the UK’s best selling and most comprehensive range of compact radiators. They’re proven, high performance winners - ideal for every room and every application where space is at a premium. 200 horizontal models Heights: 300mm to 700mm Lengths: 400mm to 3000mm Outputs: 190 to 5883 watts, 647 to 20073 Btu/hr Types: P1, K1, P+ & K2 BIM For full details please refer to pages 49-56 7 Compact Range K3 Best Sellers The Compact K3 is the ideal choice for low energy systems, providing outstanding heat output from a smaller footprint. 40 K3 models Heights: 300mm to 700mm Lengths: 400mm to 2400mm BIM Outputs: 956 to 5734 watts, 3262 to 19564 Btu/hr Type: K3 For full details please refer to pages 49-56 8 Compact Range Vertex Best Sellers The Compact Vertex is a stylish, attractive radiator for applications where space is at a premium. The Compact Vertex is designed to complement the Stelrad Compact range 21 vertex models Heights: 1800mm, 2000mm & 2200mm Lengths: 300mm to 700mm Outputs: 1146 to 3003 watts, 3910 to 10246 Btu/hr Types: BIM P2 & K2 For full details please refer to pages 49-56 9 STR Best Sellers This simple design is the ultimate in neat, efficient functionality for towel warming and space heating. The superbly integrated unit allows towels and clothes to warm without interfering with the vital flow of convected room heat. 5 models Heights: 645mm & 745mm Lengths: 425mm & 625mm Outputs: 419 to 922 watts, 1430 to 3147 Btu/hr Type: K1 For full details please refer to pages 57-58 10 Towel Rail Range Best Sellers Stelrad Towel Rails offer stylish looks and effective heating and drying performance - in the bathroom or in the kitchen. Available from stock in white or chrome. 26 models Heights: 678mm to 1744mm Lengths: 400mm, 500mm & 600mm Outputs: 240 to 1022 watts, 820 to 3489 Btu/hr Types: BIM Straight, curved, white or chrome For full details please refer to pages 59-60 11 Caliente Range Straight Towel Rails Best Sellers Elegant tube on tube design consisting of a tight array of slim tubes makes the Caliente Towel Rail an easy choice for any bathroom or kitchen whether it’s a modern, contemporary or period interior. Double Single 32 straight models (single & double rail) Heights: 755mm to 2013mm Lengths: 450mm to 750mm BIM Outputs: 389 to 2321 watts, 1327 to 7919 Btu/hr For full details please refer to pages 61-62 For colour options please refer to page 146 12 Caliente Range New Curved Towel Rail Best Sellers The stylish Caliente Curved Towel Rail will complement your bathroom or en-suite whatever your décor. Colour shown is ML130 Blue Grey 6 curved models Heights: 1199mm, 1791mm & 2013mm Lengths: 496mm & 595mm Outputs: 675 to 1294 watts, 2303 to 4415 Btu/hr BIM For full details please refer to pages 61-62 For colour options please refer to page 146 13 Concord Towel Rail Best Sellers The Concord Towel Rail offers a stunning alternative to tubular towel rails. Offering visual appeal combined with advanced technology, the Concord Towel Rail provides a contemporary solution for a wide range of building applications. 8 models Heights: 730mm to 1770mm Lengths: 450mm & 600mm BIM Outputs: 342 to 1010 watts, 1167 to 3446 Btu/hr For full details please refer to page 63 For colour options please refer to page 146 14 Esprit Best Sellers Elegant and ultra slim, Esprit is a beautifully stylish range of radiators that’s great for space saving and it looks simply stunning. 16 models Heights: 900mm to 1800mm Lengths: 450mm & 550mm Outputs: 316 to 1056 watts, 1078 to 3604 Btu/hr Types: BIM Straight, curved, white or chrome For full details please refer to pages 64-65 15 Softline Best Sellers Compact and with a beautifully curved top grille and end panels, the designer looks of the Softline range give you extra choice and flexibility for domestic and commercial applications. 102 models Heights: 300mm to 700mm Lengths: 400mm to 2000mm BIM Outputs: 255 to 3922 watts, 870 to 13382 Btu/hr Types: K1, P+ and K2 For full details please refer to pages 66-70 16 designer With a brilliant blend of form and function, Stelrad’s range of super-stylish radiators give you extensive options to express and complement any design concept. Subtle, striking, classic or contemporary there are hundreds of models to choose from, in all sorts of shapes, sizes and colours, to suit any living space. Radiators which can become a design feature, or a discreet addition to any room - whatever effect you’re looking for, Stelrad help you achieve it, and all with great heating performance too. 17 Compact with Style Range Designer Horizontal & Lo-Line The subtle architectural look and feel of the Compact with Style is combined with value, range and availability to give you sophisticated designer styling for any room, commercial or domestic, at affordable prices. Horizontal BIM 52 horizontal models 12 Lo-Line models Heights: 200mm to 600mm 200mm Lengths: 400mm to 2000mm 500mm to 2000mm Outputs: 235 to 3202 watts, 802 to 10925 Btu/hr 125 to 966 watts, 425 to 3296 Btu/hr Types: K1, P+ & K2 K1, P+ & K2 For full details please refer to pages 73-79 18 Lo-Line For colour options please refer to page 146 Compact with Style Range Designer Vertical 24 vertical models Heights: 1600mm to 2200mm Lengths: 300mm to 700mm Outputs: 693 to 2772 watts, 2365 to 9458 Btu/hr Types: P2 & K2 BIM For full details please refer to pages 73-79 19 Planar Range Designer Horizontal Simple and understated design makes Planar the ultimate in minimalism for radiators. With its completely flat, smooth finish and integrated top grille and side panels it has a remarkably slim and stylish profile that will enhance any space. 100 horizontal models BIM Heights: 300mm to 700mm Lengths: 400mm to 3000mm Outputs: 235 to 4901 watts, 802 to 16729 Btu/hr Types: K1 & K2 For full details please refer to pages 80-86 For colour options please refer to page 146 20 Planar Range Designer Vertical 12 vertical models Heights: 1800mm, 2000mm & 2200mm Lengths: 400mm to 700mm Outputs: 1476 to 2961 watts, 5036 to 10103 Btu/hr Types: K2 BIM For full details please refer to pages 80-86 21 Designer Concord Range Concord creates a distinctive look for any room, with four super-stylish design options from the Lo-Line at just 144mm high to the Vertical at up to 2 metres, and every height in between. Flexible, highly efficient and very, very good looking. Choice of 4 different radiator options 1. Concord Vertical: Slimline 6 models, 2 heights and 3 lengths 2. Concord Slimline: 8 models, 2 heights and 4 lengths 3. Concord Lo-Line: 16 models, 2 heights and 8 lengths Vertical BIM 4. Concord Plane: Outputs: 102 models, 3 heights, lengths from 500mm to 3000mm 382 to 6276 watts, 1303 to 21419 Btu/hr For full details please refer to pages 87-95 22 For colour options please refer to page 147 Designer Concord Range Colour shown is RAL 1004 Lo-Line Plane 23 Classic Column Range Designer Horizontal 54 horizontal models Heights: 300mm to 750mm Lengths: 444mm to 1870mm Outputs: 288 to 2972 watts, 983 to 10140 Btu/hr Types: 2, 3 & 4 columns For full details please refer to pages 96-99 For colour options please refer to page 147 24 BIM Classic Column Range Designer Vertical A timeless classic design, to complement both contemporary and traditional interiors. The Classic Column is a real style statement, with a beautiful finish and sizes to suit almost any space. 6 vertical models Heights: 1800mm, 2000mm & 2500mm Lengths: 352mm & 444mm Outputs: 868 to 1539 watts, 2962 to 5251 Btu/hr Types: 2 column BIM For full details please refer to pages 96-99 For colour options please refer to page 147 25 Designer Swing The curved cover of the Swing makes it a focal point in any room. And with a choice of 35 colours you can make a real statement. Colour shown is A3002 Carmine Red 12 models Heights: 1820mm & 2020mm Lengths: 504mm to 727mm BIM Outputs: 1224 to 2376 watts, 4176 to 8107 Btu/hr Types: P+ & K2 For full details please refer to page 100-101 For colour options please refer to page 146 26 Designer Caliente Smart design, with slim tubes in a tight row, not only makes the Caliente range look great it also delivers a high heat output. Available in horizontal or vertical models to add style to any interior. 15 models Heights: 594mm to 1800mm Lengths: 330mm to 1400mm Outputs: 485 to 2120 watts, 1655 to 7233 Btu/hr Types: BIM Single, Double, Horizontal & Vertical For full details please refer to pages 102-104 27 Designer Excel Both a screen and a radiator, the Excel - which can be floor or wall mounted - is a practical and stylish design for domestic or commercial applications. Available in six models. 6 models Heights: 1800mm & 2000mm Lengths: 380mm & 500mm Outputs: 727 to 1048 watts, 2481 to 3577 Btu/hr Types: Wall & floor mounted For full details please refer to page 105 28 Designer Arc & Wave Precision curved fine tubes create the flowing, elegant form of the Arc & Wave - making them a clear style statement for any living space. 6 models Heights: 1800mm Lengths: 380mm, 440mm & 620mm Outputs: 882 to 1438 watts, 3010 to 4908 Btu/hr For full details please refer to page 106 29 Designer Vistaline The tightly aligned slim tubes of the Vistaline don’t just look great, they also deliver a superb heating performance. Available with tubes in a single or staggered double row for maximum output flexibility, and in a wide range of colours. 11 models Heights: 1800mm & 2000mm Lengths: 320mm to 740mm Outputs: 742 to 1886 watts, 2542 to 6437 Btu/hr Types: 2&3 For full details please refer to page 107 For colour options please refer to page 147 30 Designer Ellipse Vertical C shaped tubes in inward or outward facing columns give the Ellipse a distinctive look and make it a feature in any room. The large capacity of the tubes also delivers outstanding heating performance. Available in a wide range of colours. 10 models Heights: 1800mm & 2000mm Lengths: 459mm, 689mm & 765mm Outputs: 858 to 1590 watts, 2928 to 5427 Btu/hr Types: Inward or outward facing columns For full details please refer to page 108 For colour options please refer to page 147 31 Designer Optia Pietro Facheris’ iconic design, affectionately known as ‘the boat’, delivers excellent heat output and cleverly integrated towel stacking spaces. Available in three lengths, and finished in cool metallic grey. 3 models Heights: 1800mm Lengths: 220mm Depths: 160mm, 200mm & 240mm Outputs: 742 to 1114 watts, 2532 to 3802 Btu/hr For full details please refer to page 109 32 energy saving Radical thinking by Stelrad The European Union are making energy consumption standards stricter, so here at Stelrad we believe the heating industry has a major role to play, by developing systems that work so efficiently that they produce more heat at lower temperatures. Reducing energy bills by up to 10.5% Up to 50% more radiant heat Up to 23% faster to heat up Up to 53% hotter at the front Significantly less heat loss from the back More comfort at a lower setting Pre-set valves save up to 6% energy Eco-friendly Compatible with renewable energy sources Easy central fitting with left or right side valve position • The power we use in buildings, accounts for 40% of global consumption • With smarter energy management, our buildings can emit up to 60% less CO2 • The European Union are making consumption standards stricter • The new Stelrad Radical produces more radiant heat than traditional radiators saving energy while raising comfort levels • At less cost to the user and to the environment 33 Radical Energy Saving The Radical Energy Saving Radiator can save up to 10.5% on energy bills, delivering higher comfort levels at a lower thermostat setting. That’s radical thinking, from Stelrad. 33 models CPD Heights: 300mm to 600mm Lengths: 400mm to 2000mm BIM Outputs: 333 to 3234 watts, 1136 to 11034 Btu/hr Types: K1 & K2 ‘Retro-fit Product of the Year’ For full details please refer to pages 110-126 34 safety The Stelrad Low Surface Temperature (LST) range offers you the ideal solution for many special environments like healthcare and schools with low surface temperatures and antibacterial paint so they’re safe to touch. LST Plus incorporates an integral remote sensing thermostat valve for even higher safety levels, the LST i Plus also offers this along with improved heat outputs. Our LST Plus Vertical gives you additional design choices and flexibility. 35 LST Range Standard Safety Stelrad’s range of Low Surface Temperature radiators is the most comprehensive in the UK, with sizes and models to suit all applications. They all meet NHS Guidance for ‘safe hot water and surface temperature’ and are finished with antibacterial paint as standard, making them the No.1 choice for safety-critical environments. Installation is simple and all components are included in a single robust pack. Standard 72 models Heights: 500mm, 600mm & 800mm Lengths: 560mm to 1960mm CPD BIM Outputs: 196 to 2767 watts, 668 to 9442 Btu/hr Types: K1, P+ & K2 For full details please refer to pages 129-132 36 LST Range Safety Plus Vertical Plus Vertical 3 models Height: 2110mm Lengths: 560mm, 660mm & 760mm Outputs: 1335 to 1862 watts, 4555 to 6353 Btu/hr Type: CPD BIM K2 For full details please refer to pages 133-134 37 LST Range Safety Plus Plus 72 models Heights: 500mm, 650mm & 750mm Lengths: 650mm to 2050mm CPD BIM Outputs: 203 to 2511 watts, 692 to 8566 Btu/hr Types: K1, P+ & K2 For full details please refer to pages 135-140 38 LST Range Safety i Plus i Plus 72 models Heights: 500mm, 650mm & 800mm Lengths: 650mm to 2050mm Outputs: 196 to 2767 watts, 669 to 9441 Btu/hr Types: CPD BIM K1, P+ & K2 For full details please refer to pages 141-144 39 Technical Introduction Technical Temperature table Many technical features are constant across the Stelrad ranges, as outlined here - apart from the Radical Energy Saving Radiator, which has its own technical information pages (see page 110). Each section’s introduction page provides you with any further technical information specific to the ranges included. Extra performance to guaranteed standards Stelrad combine the most sophisticated production resources in Europe with substantial investment in testing and verification of performance data - which has helped us create high output radiators delivering heating performance that exceeds expectation. More choice for application flexibility A range of models provide extra sizing flexibility and covers a multitude of application requirements, including those where there are installation difficulties or where wall space is at a premium. Superb quality from design to installation Our radiators are specifically designed to minimise any movement, providing a tight, professional fit, that will remain in place, even after storage, transit and installation. Convectors are precision welded directly onto the waterways for greater efficiency and economy, with flexible connection options for the highest of commercial and domestic application specifications. Stelrad radiators are manufactured under ISO 9001 quality systems in the UK and every one comes wrapped in robust, practical packaging that will keep the product pristine, right through to installation. This clever packaging design allows installation to be completed prior to removal. 40 For systems not operating at ∆t50 the factors in the table below should be applied. The output of a given radiator can be obtained by multiplying the quoted ∆t50 output by the operating factor. Conversely, to derive a non ∆t50 output, divide the heat output required by the relevant operation factor. This ‘∆t50 equivalent output’ can then be used to select a radiator from the standard tables. ∆t °C Operating Factor ∆t °F Operating Factor 5 0.050 10 0.057 10 0.123 20 0.142 15 0.209 30 0.240 20 0.304 40 0.348 25 0.406 50 0.466 30 0.515 60 0.590 35 0.629 70 0.721 40 0.748 80 0.858 45 0.872 90 1.000 50 1.000 100 1.147 55 1.132 110 1.298 60 1.267 120 1.454 65 1.406 130 1.613 70 1.549 150 1.776 75 1.694 - - Example: Exact output at ∆t50 = 2000 Btu/hr Output at ∆t30 = 2000 x 0.515 = 1030 Btu/hr Testing and operating pressures All models are high pressure tested to withstand 152.3 psi (10.5 bar). Strictly controlled independent laboratory testing ensures that all Stelrad radiators are guaranteed to perform to a maximum working pressure of 116 psi (8 bar) at a maximum temperature of 95°C. All conform to BS EN 442 - the European Standard for radiators. Connections Each radiator has 4 x 1⁄2" connections as standard. A 3⁄4" valve adaptor is also available, providing a 3 ⁄4" connector option to the valve without reducing performance. (Please note: Concord and Radical have different connections. See pages 71 and 121) Technical Introduction information Applications Stelrad radiators are suitable for two pipe installations. For single pipe applications, it is advisable to use diversion tees in the pipework, as this will assist in obtaining design performance from the radiators. Although our radiators are suitable for Microbore pipework, the back tappings make them unsuitable for twin entry valves. Installation Everything required for installation can be found within each radiator’s packaging. Brackets are of a strong design, with open top and deep slots, which facilitate easy and secure installation. Plastic inserts seat the radiator precisely on the bracket minimising expansion and contraction noise. The neat nickel-plated plug and vent provide a watertight joint, whilst complementing the superior finish. To facilitate easy one off replacement, nickel-plated brass extension pieces are also available, complete with sealing washer, in 20mm, 30mm and 40mm options. Recommended height from the floor to the base of the radiator is 150mm minimum. This allows adequate airflow when the radiator is placed on the bracket. Caution When designing for domestic systems we recommend that the Stelrad radiators are only used in heating systems complying with British Standard Code of Practice for Central Heating for Domestic Premises BS EN 12828:2003 and BS EN 12831:2003. After installation of a new Stelrad radiator the central heating system should be cleaned and flushed with cleaner to remove existing contaminants, flux residue and other installation debris which, if left, can cause damage to the new radiator. Afterwards, treat the system with an inhibitor to ensure long term protection against corrosion and limescale. A comprehensive range of quality chemicals including inhibitors, cleaners, leak sealers and noise reducers that protect and maintain central heating systems can be obtained from: Sentinel Performance Solutions Ltd The Heath Business & Technical Park, Runcorn, Cheshire WA7 4QX Tel: 01928 588 330 (UK) www.sentinel-solutions.net Fernox - Cookson Electronics, Forsyth Road, Sheerwater, Woking, Surrey GU21 5RZ www.fernox.com Two coat paint process Each Stelrad radiator is subjected to a multi stage cleaning process before the paint is applied. This involves several rinsing stages, including an iron phosphate and demineralisation rinse. The first coat of paint is applied by electrophoresis and the radiator is then stoved and cooled. The second powder coat in warm white (RAL 9016) is applied and the radiator goes through a final curing stage. It is then allowed to cool, prior to packaging. Single feed, direct cylinders are not recommended as should interchange of water occur, fresh aerated water would enter the heating system, resulting in corrosion. Water treatment On completion of the installation, the system should be properly flushed and filled in accordance with the British Standard Code of Practice BS 7593:2006 for the Treatment of Water in Domestic Hot Water Central Heating Systems, Part L of Building Regulations and Good Practice Guidance for Scotland. For further information and advice call 0844 543 6200 41 Technical Introduction Packaging Compact illustrated only Robust packaging protects the product All fixing requirements are The Stelrad STARS Heatloss right through to hand over. Installation complete within the packaging. Calculator contains an inbuilt instructions can be found on the reverse Content will vary depending U value calculator. of the identification label. on product. Save time and effort by using Example packaging only. The packaging the Stelrad STARS program - for each radiator will vary. the perfect solution for accurate sizing and design flexibility. Visit www.starsapp.co.uk Accessories Full height and anti-lift Additional Towel Rail. 30cm, brackets are available 40cm, 46cm or 62cm for a secure fixing in For Ellipse, Esprit and commercial applications. Vistaline 2 (except 320 width). Floor mounting brackets provide Classic Column floor Optional extension Chrome robe hooks. a practical solution for standard standing feet. pieces for easy For Vistaline, Ellipse replacement. and Esprit. Optional 3⁄4" inch Drying & stacking rail, valve adaptor for 55cm for Vistaline and Ellipse. and towel rail models, where situations, such as tiled walls, create installation difficulties. Electric Heater Element Kit (Towel Rail Elements) Part Supplied Optional Fittings Supplied connection without performance reduction. T-Piece Blanking Plug Preset key. (Radical only) Part of the hardware pack. ElectricHeating Element 42 UIN no. 9222. Best Sellers Elite Caliente Towel Rail • The UK’s most popular radiator now delivers • Elegant tube on tube design improved outputs for exceptional heating performance • Specifically designed accessories, such as floor standing brackets, ensure that Stelrad Elite can be fitted anywhere • Symmetrical convectors allow radiator mounting either way up • TBOE connection ensures greater efficiency and economy • Ideal for modern, contemporary or period features • Range of sizes and outputs • Available in straight or curved • For colour options refer to page 146 Concord Towel Rail • Flat rail design • All tappings are perfectly aligned, with best quality • Contemporary styling nickel-plated plugs and vents, incorporating high quality EPDM ‘O’ rings • Advanced technology • High definition pressings ensure smooth edges and corners and the perfect, run free, two-coat paint finish blends with all styles of décor • White as standard Compact Range • The vast and flexible Compact range now includes the new K3 three panel, three convector option • Range of sizes and outputs • For colour options refer to page 146 Esprit • Slim tubes give elegance to this beautiful ultra slim radiator • Floor or wall mounted • Available in 16 model options • Outstanding heat performance for smaller footprint • Available in chrome, white, straight or curved • Ideal for low energy systems Softline • White as standard STR • This simple design allows both towel warming and space heating • The ultimate in neat, efficient functionality • Allows towels and clothes to warm without interfering with the flow of convected heat • White as standard Towel Rails • Range of sizes and outputs • Towel rails offered with straight or curved rails • Available in a white or chrome finish • Special colour options available on request • Electric heater kits available Best Sellers Our best selling ranges make Stelrad the UK’s most popular radiator brand - not just for good looks and great heating, but also for outstanding technical performance. • Elegantly curved top grille and end panels • High output radiator with heating performance which exceeds expectation • Panels have been designed to eradicate any movement, providing a tight, professional fit • Excellent efficiency and economical • White as standard To underline their all-round dependable quality and performance, the Stelrad best selling Elite, Compact, STR and Softline come complete with a 10 year Manufacturer’s Warranty. The Towel Rail and Esprit come complete with a 5 year Manufacturer’s Warranty. For further information and advice call 0844 543 6200 43 Stelrad Elite 50 Δt Height Best Sellers - Elite 300 450 600 700 P1 K1 P+ K2 (75/65/20°C) Length mm Sections 500 1000 1500 2000 2500 3000 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 15 30 45 60 75 90 12 15 18 21 24 27 30 33 36 42 48 54 60 66 72 78 84 90 12 15 18 21 24 27 30 33 36 42 48 54 60 66 72 78 84 90 12 15 18 21 24 27 30 33 36 42 48 54 60 66 72 78 84 90 UIN 8448 8449 8450 8451 8452 8453 8454 8456 8457 8458 8459 8460 8515 8516 8517 8518 8519 8520 8521 8523 8524 8525 8526 8527 - Heat output Watts Btu/hr 190 238 286 333 381 428 476 571 666 762 952 1142 244 305 366 427 488 549 610 732 854 976 1220 1464 - 648 812 976 1136 1300 1460 1624 1948 2272 2600 3248 3897 833 1041 1249 1457 1665 1873 2081 2498 2914 3330 4163 4995 - UIN 8430 8431 8432 8433 8434 8435 8461 8462 8463 8464 8465 8466 8467 8468 8469 8470 8471 8472 8473 8474 8475 8476 8477 8478 8528 8529 8530 8531 8532 8533 8534 8535 8536 8537 8538 8539 8540 8541 8542 8543 8544 8545 8595 8596 8597 8598 8599 8600 8601 8602 8603 8604 8605 8606 8607 8608 8609 8610 8611 8612 Heat output Watts Btu/hr UIN Heat output Watts Btu/hr UIN 259 517 776 1034 1293 1551 307 384 461 538 614 691 768 845 922 1075 1229 1382 1536 1690 1843 1997 2150 2304 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 457 571 685 799 914 1028 1142 1256 1370 1599 1827 2056 2284 2512 2741 2969 3198 3426 8436 8437 8438 8439 8440 8441 8479 8480 8481 8482 8483 8484 8485 8486 8487 8488 8489 8490 8491 8492 8493 8494 8495 8496 8546 8547 8548 8549 8550 8551 8552 8553 8554 8555 8556 8557 8558 8559 8560 8561 8562 8563 8613 8614 8615 8616 8617 8618 8619 8620 8621 8622 8623 8624 8625 8626 8627 8628 8629 8630 388 776 1164 1552 1940 2328 442 553 664 774 885 995 1106 1217 1327 1548 1770 1991 2212 2433 2654 2876 3097 3318 564 705 845 986 1127 1268 1409 1550 1691 1973 2254 2536 2818 3100 3382 3663 3945 4227 639 799 958 1118 1278 1437 1597 1757 1916 2236 2555 2875 3194 3513 3833 4152 4472 4791 1324 2648 3972 5295 6621 7945 1508 1887 2266 2641 3020 3395 3774 4152 4528 5282 6039 6793 7547 8301 9055 9813 10567 11321 1924 2405 2883 3364 3845 4326 4808 5289 5770 6732 7691 8653 9615 10577 11539 12498 13460 14423 2180 2726 3269 3815 4361 4903 5449 5995 6537 7629 8718 9810 10898 11986 13078 14167 15258 16347 8442 8443 8444 8445 8446 8447 8497 8498 8499 8500 8501 8502 8503 8504 8505 8506 8507 8508 8509 8510 8511 8512 8513 8514 8564 8565 8566 8567 8568 8569 8570 8571 8572 8573 8574 8575 8576 8577 8578 8579 8580 8581 8631 8632 8633 8634 8635 8636 8637 8638 8639 8640 8641 8642 8643 8644 8645 8646 8647 8648 884 1764 2648 3528 4412 5292 1047 1310 1573 1836 2095 2358 2620 2883 3146 3668 4193 4715 5241 5766 6288 6814 7336 7861 1365 1706 2047 2388 2730 3071 3412 3753 4094 4777 5459 6142 6824 7509 8189 8871 9554 10239 1559 1948 2337 2726 3119 3508 3897 4285 4674 5456 6234 7015 7793 8571 9352 10130 10912 11690 Heat output Watts Btu/hr 506 1012 1518 2024 2530 3036 564 705 845 986 1127 1268 1409 1550 1691 1973 2254 2536 2818 3100 3382 3663 3945 4227 711 889 1067 1245 1422 1600 1778 1956 2134 2489 2845 3200 3556 3912 4267 4623 4978 5334 804 1006 1207 1408 1609 1810 2011 2212 2413 2815 3218 3620 4022 4424 4826 5229 5631 6033 1726 3453 5179 6906 8632 10359 1924 2405 2883 3364 3845 4326 4808 5289 5770 6732 7691 8653 9615 10577 11539 12498 13460 14423 2426 3033 3641 4248 4852 5459 6067 6674 7281 8492 9707 10918 12133 13348 14559 15774 16985 18200 2743 3432 4118 4804 5490 6176 6862 7547 8233 9605 10980 12351 13727 15099 16471 17847 19219 20591 ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). 44 Stelrad Elite Height 300 450 600 700 K1 P+ K2 (65/55/20°C) Length mm Sections 500 1000 1500 2000 2500 3000 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 15 30 45 60 75 90 12 15 18 21 24 27 30 33 36 42 48 54 60 66 72 78 84 90 12 15 18 21 24 27 30 33 36 42 48 54 60 66 72 78 84 90 12 15 18 21 24 27 30 33 36 42 48 54 60 66 72 78 84 90 UIN 8448 8449 8450 8451 8452 8453 8454 8456 8457 8458 8459 8460 8515 8516 8517 8518 8519 8520 8521 8523 8524 8525 8526 8527 - Heat output Watts Btu/hr 142 178 214 249 285 320 356 427 498 570 712 854 183 228 274 319 365 411 456 548 639 730 913 1095 - 485 607 730 850 972 1092 1215 1457 1700 1945 2430 2915 623 778 934 1090 1245 1401 1557 1868 2180 2491 3114 3736 - UIN 8430 8431 8432 8433 8434 8435 8461 8462 8463 8464 8465 8466 8467 8468 8469 8470 8471 8472 8473 8474 8475 8476 8477 8478 8528 8529 8530 8531 8532 8533 8534 8535 8536 8537 8538 8539 8540 8541 8542 8543 8544 8545 8595 8596 8597 8598 8599 8600 8601 8602 8603 8604 8605 8606 8607 8608 8609 8610 8611 8612 Heat output Watts Btu/hr UIN Heat output Watts Btu/hr 194 387 580 773 967 1160 230 287 345 402 459 517 574 632 690 804 919 1034 1149 1264 1379 1494 1608 1723 299 374 449 524 598 673 748 823 898 1047 1197 1346 1496 1646 1795 1945 2094 2244 342 427 512 598 684 769 854 939 1025 1196 1367 1538 1708 1879 2050 2221 2392 2563 8436 8437 8438 8439 8440 8441 8479 8480 8481 8482 8483 8484 8485 8486 8487 8488 8489 8490 8491 8492 8493 8494 8495 8496 8546 8547 8548 8549 8550 8551 8552 8553 8554 8555 8556 8557 8558 8559 8560 8561 8562 8563 8613 8614 8615 8616 8617 8618 8619 8620 8621 8622 8623 8624 8625 8626 8627 8628 8629 8630 290 580 871 1161 1451 1741 331 414 497 579 662 744 827 910 993 1158 1324 1489 1655 1820 1985 2151 2317 2482 422 527 632 738 843 948 1054 1159 1265 1476 1686 1897 2108 2319 2530 2740 2951 3162 478 598 717 836 956 1075 1195 1314 1433 1673 1911 2151 2389 2628 2867 3106 3345 3584 661 1319 1980 2639 3300 3958 784 980 1177 1373 1567 1764 1960 2157 2353 2744 3137 3527 3920 4313 4704 5097 5487 5880 1021 1276 1531 1787 2042 2297 2552 2807 3063 3573 4083 4594 5104 5615 6125 6636 7146 7657 1166 1457 1748 2039 2333 2624 2915 3206 3496 4081 4663 5247 5829 6411 6996 7577 8162 8744 990 1980 2971 3961 4951 5941 1128 1411 1695 1975 2259 2539 2823 3106 3387 3951 4517 5081 5645 6209 6773 7340 7904 8468 1439 1799 2157 2516 2876 3236 3596 3956 4316 5035 5753 6472 7192 7912 8631 9349 10068 10788 1631 2039 2445 2853 3262 3667 4076 4484 4890 5707 6521 7338 8152 8966 9782 10597 11413 12227 UIN 8442 8443 8444 8445 8446 8447 8497 8498 8499 8500 8501 8502 8503 8504 8505 8506 8507 8508 8509 8510 8511 8512 8513 8514 8564 8565 8566 8567 8568 8569 8570 8571 8572 8573 8574 8575 8576 8577 8578 8579 8580 8581 8631 8632 8633 8634 8635 8636 8637 8638 8639 8640 8641 8642 8643 8644 8645 8646 8647 8648 Heat output Watts Btu/hr 378 757 1135 1514 1892 2271 422 527 632 738 843 948 1054 1159 1265 1476 1686 1897 2108 2319 2530 2740 2951 3162 532 665 798 931 1064 1197 1330 1463 1596 1862 2128 2394 2660 2926 3192 3458 3724 3990 601 752 903 1053 1204 1354 1504 1655 1805 2106 2407 2708 3008 3309 3610 3911 4212 4513 1291 2583 3874 5166 6457 7748 1439 1799 2157 2516 2876 3236 3596 3956 4316 5035 5753 6472 7192 7912 8631 9349 10068 10788 1815 2269 2723 3177 3629 4083 4538 4992 5446 6352 7261 8167 9076 9984 10890 11799 12705 13613 2052 2567 3080 3593 4106 4619 5132 5645 6158 7184 8213 9239 10265 11291 12317 13345 14371 15397 Best Sellers - Elite 40 Δt P1 45 Stelrad Elite 30 Δt P1 P+ K2 (55/45/20°C) Height Length mm Sections 500 1000 1500 2000 2500 3000 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 15 30 45 60 75 90 12 15 18 21 24 27 30 33 36 42 48 54 60 66 72 78 84 90 12 15 18 21 24 27 30 33 36 42 48 54 60 66 72 78 84 90 12 15 18 21 24 27 30 33 36 42 48 54 60 66 72 78 84 90 300 Best Sellers - Elite K1 450 600 700 UIN 8448 8449 8450 8451 8452 8453 8454 8456 8457 8458 8459 8460 8515 8516 8517 8518 8519 8520 8521 8523 8524 8525 8526 8527 - Heat output Watts Btu/hr 98 123 147 171 196 220 245 294 343 392 490 588 126 157 188 220 251 283 314 377 440 503 628 754 - UIN 8430 8431 8432 8433 8434 8435 8461 8462 8463 8464 8465 8466 8467 8468 8469 8470 8471 8472 8473 8474 8475 8476 8477 8478 8528 8529 8530 8531 8532 8533 8534 8535 8536 8537 8538 8539 8540 8541 8542 8543 8544 8545 8595 8596 8597 8598 8599 8600 8601 8602 8603 8604 8605 8606 8607 8608 8609 8610 8611 8612 334 418 503 585 669 752 836 1003 1170 1339 1673 2007 429 536 643 750 858 965 1072 1286 1501 1715 2144 2573 - Heat output Watts Btu/hr UIN Heat output Watts Btu/hr 455 908 1364 1817 2272 2725 539 675 810 945 1079 1214 1350 1485 1620 1889 2160 2428 2699 2970 3238 3509 3778 4049 703 879 1054 1230 1406 1581 1757 1933 2109 2460 2811 3163 3514 3866 4217 4569 4920 5272 803 1003 1204 1404 1606 1806 2007 2207 2407 2810 3210 3613 4013 4414 4816 5217 5619 6020 8436 8437 8438 8439 8440 8441 8479 8480 8481 8482 8483 8484 8485 8486 8487 8488 8489 8490 8491 8492 8493 8494 8495 8496 8546 8547 8548 8549 8550 8551 8552 8553 8554 8555 8556 8557 8558 8559 8560 8561 8562 8563 8613 8614 8615 8616 8617 8618 8619 8620 8621 8622 8623 8624 8625 8626 8627 8628 8629 8630 200 400 599 799 999 1199 228 285 342 399 456 512 570 627 683 797 912 1025 1139 1253 1367 1481 1595 1709 290 363 435 508 580 653 726 798 871 1016 1161 1306 1451 1597 1742 1886 2032 2177 329 411 493 576 658 740 822 905 987 1152 1316 1481 1645 1809 1974 2138 2303 2467 133 266 400 533 666 799 158 198 237 277 316 356 396 435 475 554 633 712 791 870 949 1028 1107 1187 206 258 309 361 412 464 515 567 618 721 824 927 1030 1133 1236 1339 1442 1545 235 294 353 411 471 529 588 647 706 823 941 1059 1176 1294 1412 1529 1647 1764 682 1364 2045 2727 3409 4091 777 972 1167 1360 1555 1748 1943 2138 2332 2720 3110 3499 3887 4275 4664 5054 5442 5830 991 1239 1485 1733 1980 2228 2476 2724 2971 3467 3961 4456 4952 5447 5943 6437 6932 7428 1123 1404 1683 1965 2246 2525 2806 3087 3367 3929 4490 5052 5612 6173 6735 7296 7858 8419 UIN Heat output Watts Btu/hr 8442 8443 8444 8445 8446 8447 8497 8498 8499 8500 8501 8502 8503 8504 8505 8506 8507 8508 8509 8510 8511 8512 8513 8514 8564 8565 8566 8567 8568 8569 8570 8571 8572 8573 8574 8575 8576 8577 8578 8579 8580 8581 8631 8632 8633 8634 8635 8636 8637 8638 8639 8640 8641 8642 8643 8644 8645 8646 8647 8648 261 889 521 1778 782 2667 1042 3557 1303 4446 1564 5335 290 991 363 1239 435 1485 508 1733 580 1980 653 2228 726 2476 798 2724 871 2971 1016 3467 1161 3961 1306 4456 1451 4952 1597 5447 1742 5943 1886 6437 2032 6932 2177 7428 366 1249 458 1562 550 1875 641 2188 732 2499 824 2811 916 3124 1007 3437 1099 3750 1282 4374 1465 4999 1648 5623 1831 6249 2015 6874 2198 7498 2381 8123 2564 8747 2747 9373 414 1413 518 1768 622 2121 725 2474 829 2827 932 3180 1036 3534 1139 3887 1243 4240 1450 4946 1657 5655 1864 6361 2071 7067 2278 7774 2485 8480 2693 9188 2900 9895 3107 10601 EN 442 Certification Data – CETIAT tested in accordance with BS EN 442 46 Type Height W/m at 75/65/20 n-coefficients Heated Surface Area (m2/m) Weight (kg/m) Water Contents (l/m) 450 476 1.30 1.03 9.25 2.57 P1 Wall to tap centre (mm) 46 600 610 1.31 1.37 12.33 3.25 300 517 1.31 2.09 8.38 1.89 46 51 K1 450 600 768 1000 1.30 1.29 3.37 4.66 13.34 18.30 2.57 3.25 51 51 700 1142 1.29 5.51 21.33 3.77 51 300 776 1.33 2.44 13.71 3.70 62 P+ 450 600 1106 1409 1.33 1.33 3.84 5.24 21.31 28.90 5.15 6.60 62 62 700 1597 1.34 6.18 33.50 7.63 300 1012 1.33 3.51 15.90 3.70 62 73 K2 450 600 1409 1778 1.33 1.23 5.62 7.74 24.80 33.70 5.15 6.60 73 73 700 2011 1.34 9.15 39.13 7.63 73 Elite mounting brackets All dimensions in mm. Inches in brackets. Floor mounting brackets available. Best Sellers - Elite See page 42. E E 11 (0.43) D C 11 (0.43) D 11 (0.43) C 11 (0.43) 11 (0.43) E D B B B A A A 54 (2.13) 25 (0.98) 14 (0.55) 25 (0.98) 14 (0.55) 61 (2.40) 32 (1.26) 21 (0.83) 32 (1.26) 21 (0.83) P1 K1, P+ and K2 (300mm) Dimensions Rad height A B C D E mm 300 65 119 153 185 in 11.81 2.56 4.69 6.02 7.28 mm 450 65 99 269 303 335 in 17.72 2.56 3.90 10.59 11.93 13.19 K1, P+, K2 and P1 lug positions K1, P+ and K2 (Over 300mm) mm 600 65 99 419 453 485 in 23.62 2.56 3.90 16.50 17.83 19.09 mm 700 65 99 519 553 585 in 27.56 2.56 3.90 20.43 21.77 23.03 Pressure drops All dimensions in mm. Inches in brackets. P1, P+ & K2 Dimensions A B mm 133 60 Panel Height mm in 300 11.81 450 17.72 600 23.62 700 27.56 mm 155 305 455 555 in 5.24 2.36 D K1 Dimensions A 400mm 500 - 3000mm A 400 - 3000mm B 1800 - 3000mm C mm 117 150 60 17 in 4.61 5.91 2.36 0.67 in 6.10 12.01 17.91 21.95 47 Elite wall mounting information All dimensions in mm. Inches in brackets. P+ Best Sellers - Elite K1 51 (2.01) 62 (2.45) (R) A { (R) A { 83 (3.27) 101 (3.98) 62 (2.44) 73 (2.87) B{ B{ 94 (3.70) 112 (4.41) K2 P1 73 (2.87) ONLY ONE POSITION POSSIBLE (R) A { 124 (4.88) 84 (3.31) B{ 135 (5.31) Elite bracket position A = Closest to Wall B = Furthest from Wall (R) = Recommended Mounting Position 48 46 (1.81) 78 (3.07) Elite piping options Stelrad Compact Range Height 300 450 500 600 700 K1 P+ K2 K3 (75/65/20°C) Length mm Sections 500 1000 1500 2000 2500 3000 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2400 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 15 30 45 60 75 90 12 15 18 21 24 27 30 33 36 42 48 54 60 66 72 78 84 90 18 21 24 27 30 33 36 42 48 54 60 72 12 15 18 21 24 27 30 33 36 42 48 54 60 66 72 78 84 90 12 15 18 21 24 27 30 33 36 42 48 54 60 66 72 78 84 90 UIN 143668 143669 143670 143671 143672 143673 143674 143675 143676 143677 143734 143735 143736 143737 143738 143739 143740 143741 143742 143743 - Heat output Watt Btu/hr 190 237 284 332 379 427 474 569 664 758 248 310 371 433 495 557 619 743 867 990 - 648 809 969 1133 1293 1457 1617 1941 2266 2586 846 1058 1266 1477 1689 1900 2112 2535 2958 3378 - UIN Heat output Watt Btu/hr UIN 143650 143651 143652 143653 143654 143655 143680 143681 143682 143683 143684 143685 143686 143687 143688 143689 143690 143691 143692 143693 143694 143695 143696 143697 143746 143747 143748 143749 143750 143751 143752 143753 143754 143755 143756 143757 143758 143759 143760 143761 143762 143763 143812 143813 143814 143815 143816 143817 143818 143819 143820 143821 143822 143823 143824 143825 143826 143827 143828 143829 255 870 509 1737 764 2607 1018 3473 1273 4343 1527 5210 302 1030 378 1290 454 1549 529 1805 605 2064 680 2320 756 2579 832 2839 907 3095 1058 3610 1210 4129 1361 4644 1512 5159 1663 5674 1814 6189 1966 6708 2117 7223 2268 7738 392 1338 490 1672 588 2006 686 2341 784 2675 882 3009 980 3344 1078 3678 1176 4013 1372 4681 1568 5350 1764 6019 1960 6688 2156 7356 2352 8025 2548 8694 2744 9363 2940 10031 447 1525 559 1907 670 2286 782 2668 894 3050 1005 3429 1117 3811 1229 4193 1340 4572 1564 5336 1787 6097 2011 6862 2234 7622 2457 8383 2681 9148 2904 9908 3128 10673 3351 11434 143656 143657 143658 143659 143660 143661 143698 143699 143700 143701 143702 143703 143704 143705 143706 143707 143708 143709 143710 143711 143712 143713 143714 143715 143764 143765 143766 143767 143768 143769 143770 143771 143772 143773 143774 143775 143776 143777 143778 143779 143780 143781 143830 143831 143832 143833 143834 143835 143836 143837 143838 143839 143840 143841 143842 143843 143844 143845 143846 143847 Heat output Watt Btu/hr 373 745 1118 1490 1863 2235 422 528 633 739 844 950 1055 1161 1266 1477 1688 1899 2110 2321 2532 2743 2954 3165 538 673 807 942 1076 1211 1345 1480 1614 1883 2152 2421 2690 2959 3228 3497 3766 4035 612 765 918 1071 1224 1377 1530 1683 1836 2142 2448 2754 3060 3366 3672 3978 4284 4590 1273 2542 3815 5084 6357 7626 1440 1802 2160 2521 2880 3241 3600 3961 4320 5040 5759 6479 7199 7919 8639 9359 10079 10799 1836 2296 2753 3214 3671 4132 4589 5050 5507 6425 7343 8260 9178 10096 11014 11932 12850 13767 2088 2610 3132 3654 4176 4698 5220 5742 6264 7309 8353 9397 10441 11485 12529 13573 14617 15661 UIN 143662 143663 143664 143665 143666 143667 143716 143717 143718 143719 143720 143721 143722 143723 143724 143725 143726 143727 143728 143729 143730 143731 143732 143733 143782 143783 143784 143785 143786 143787 143788 143789 143790 143791 143792 143793 143794 143795 143796 143797 143798 143799 143848 143849 143850 143851 143852 143853 143854 143855 143856 143857 143858 143859 143860 143861 143862 143863 143864 143865 Heat output Watt Btu/hr 491 982 1473 1964 2455 2946 548 686 823 960 1097 1234 1371 1508 1645 1919 2194 2468 2742 3016 3290 3565 3839 4113 693 866 1039 1212 1386 1559 1732 1905 2078 2425 2771 3118 3464 3810 4157 4503 4850 5196 784 981 1177 1373 1569 1765 1961 2157 2353 2745 3138 3530 3922 4314 4706 5099 5491 5883 1675 3351 5026 6701 8376 10052 1870 2341 2808 3276 3743 4210 4678 5145 5613 6548 7486 8421 9356 10291 11225 12164 13099 14034 2365 2955 3545 4135 4729 5319 5910 6500 7090 8274 9455 10639 11819 13000 14184 15364 16548 17729 2675 3347 4016 4685 5353 6022 6691 7360 8028 9366 10707 12044 13382 14719 16057 17398 18735 20073 UIN 3033310 3033320 3053306 3053307 3053308 3053309 3053310 3053311 3053312 3053314 3053316 3053318 3053320 3053324 3063304 3063305 3063306 3063307 3063308 3063309 3063310 3063311 3063312 3063314 3063316 3063318 3063320 3063324 3073305 3073306 3073307 3073308 3073309 3073310 3073311 3073312 3073314 3073316 3073318 3073320 - Heat output Watt Btu/hr 1349 2698 1234 1439 1645 1850 2056 2262 2467 2878 3290 3701 4112 4934 956 1195 1433 1672 1911 2150 2389 2628 2867 3345 3822 4300 4778 5734 1356 1627 1898 2170 2441 2712 2983 3254 3797 4339 4882 5424 - 4603 9206 4210 4910 5613 6312 7015 7718 8417 9820 11225 12628 14030 16835 3262 4077 4889 5705 6520 7336 8151 8967 9782 11413 13041 14672 16303 19564 4627 5551 6476 7404 8329 9253 10178 11103 12955 14805 16657 18507 - Best Sellers - Compact 50 Δt P1 ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). 49 Stelrad Compact Range 40 Δt Height Best Sellers - Compact 300 450 500 600 700 50 P1 K1 P+ K2 K3 (65/55/20°C) Length mm Sections 500 1000 1500 2000 2500 3000 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2400 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 15 30 45 60 75 90 12 15 18 21 24 27 30 33 36 42 48 54 60 66 72 78 84 90 18 21 24 27 30 33 36 42 48 54 60 72 12 15 18 21 24 27 30 33 36 42 48 54 60 66 72 78 84 90 12 15 18 21 24 27 30 33 36 42 48 54 60 66 72 78 84 90 UIN 143668 143669 143670 143671 143672 143673 143674 143675 143676 143677 143734 143735 143736 143737 143738 143739 143740 143741 143742 143743 - Heat output Watt Btu/hr 142 177 212 248 283 319 355 426 497 567 186 232 278 324 370 417 463 556 649 741 - 485 605 725 847 967 1090 1210 1452 1695 1935 633 791 947 1105 1263 1422 1580 1896 2213 2527 - UIN 143650 143651 143652 143653 143654 143655 143680 143681 143682 143683 143684 143685 143686 143687 143688 143689 143690 143691 143692 143693 143694 143695 143696 143697 143746 143747 143748 143749 143750 143751 143752 143753 143754 143755 143756 143757 143758 143759 143760 143761 143762 143763 143812 143813 143814 143815 143816 143817 143818 143819 143820 143821 143822 143823 143824 143825 143826 143827 143828 143829 Heat output Watt Btu/hr 191 381 571 761 952 1142 226 283 340 396 453 509 565 622 678 791 905 1018 1131 1244 1357 1471 1584 1696 293 367 440 513 586 660 733 806 880 1026 1173 1319 1466 1613 1759 1906 2053 2199 334 418 501 585 669 752 836 919 1002 1170 1337 1504 1671 1838 2005 2172 2340 2507 651 1299 1950 2598 3249 3897 771 965 1159 1350 1544 1735 1929 2123 2315 2700 3088 3474 3859 4244 4630 5018 5403 5788 1000 1251 1501 1751 2001 2251 2501 2751 3001 3502 4002 4502 5002 5502 6003 6503 7003 7503 1141 1427 1710 1996 2282 2565 2851 3137 3420 3992 4561 5132 5702 6271 6842 7412 7983 8552 UIN 143656 143657 143658 143659 143660 143661 143698 143699 143700 143701 143702 143703 143704 143705 143706 143707 143708 143709 143710 143711 143712 143713 143714 143715 143764 143765 143766 143767 143768 143769 143770 143771 143772 143773 143774 143775 143776 143777 143778 143779 143780 143781 143830 143831 143832 143833 143834 143835 143836 143837 143838 143839 143840 143841 143842 143843 143844 143845 143846 143847 Heat output Watt Btu/hr 279 557 836 1115 1394 1672 316 395 473 553 631 711 789 868 947 1105 1263 1420 1578 1736 1894 2052 2210 2367 402 503 604 705 805 906 1006 1107 1207 1408 1610 1811 2012 2213 2415 2616 2817 3018 458 572 687 801 916 1030 1144 1259 1373 1602 1831 2060 2289 2518 2747 2976 3204 3433 952 1901 2853 3803 4755 5704 1077 1348 1616 1886 2154 2425 2693 2963 3231 3770 4308 4847 5385 5924 6462 7001 7539 8078 1373 1718 2060 2404 2746 3091 3433 3777 4119 4806 5492 6179 6865 7552 8238 8925 9611 10298 1562 1952 2343 2733 3124 3514 3905 4295 4686 5467 6248 7029 7810 8591 9372 10153 10934 11714 UIN 143662 143663 143664 143665 143666 143667 143716 143717 143718 143719 143720 143721 143722 143723 143724 143725 143726 143727 143728 143729 143730 143731 143732 143733 143782 143783 143784 143785 143786 143787 143788 143789 143790 143791 143792 143793 143794 143795 143796 143797 143798 143799 143848 143849 143850 143851 143852 143853 143854 143855 143856 143857 143858 143859 143860 143861 143862 143863 143864 143865 Heat output Watt Btu/hr 367 735 1102 1469 1836 2204 410 513 616 718 821 923 1026 1128 1230 1435 1641 1846 2051 2256 2461 2667 2872 3077 518 648 777 907 1037 1166 1296 1425 1554 1814 2073 2332 2591 2850 3109 3368 3628 3887 586 734 880 1027 1174 1320 1467 1613 1760 2053 2347 2640 2934 3227 3520 3814 4107 4400 1253 2506 3759 5012 6266 7519 1399 1751 2100 2450 2800 3149 3499 3849 4198 4898 5599 6299 6998 7697 8397 9099 9798 10497 1769 2210 2652 3093 3537 3979 4420 4862 5303 6189 7072 7958 8841 9724 10609 11492 12378 13261 2001 2504 3004 3504 4004 4505 5005 5505 6005 7006 8009 9009 10010 11010 12011 13014 14014 15014 UIN 3033310 3033320 3053306 3053307 3053308 3053309 3053310 3053311 3053312 3053314 3053316 3053318 3053320 3053324 3063304 3063305 3063306 3063307 3063308 3063309 3063310 3063311 3063312 3063314 3063316 3063318 3063320 3063324 3073305 3073306 3073307 3073308 3073309 3073310 3073311 3073312 3073314 3073316 3073318 3073320 - Heat output Watt Btu/hr 1009 2018 923 1076 1230 1384 1538 1692 1845 2153 2461 2768 3076 3691 715 894 1072 1251 1429 1608 1787 1966 2145 2502 2859 3216 3574 4289 1014 1217 1420 1623 1826 2029 2231 2434 2840 3246 3652 4057 - 3443 6886 3149 3673 4198 4722 5247 5773 6296 7345 8397 9446 10495 12592 2440 3050 3657 4267 4877 5487 6097 6707 7317 8537 9754 10974 12194 14634 3461 4152 4844 5538 6230 6922 7613 8305 9691 11074 12460 13843 - Stelrad Compact Range Height 300 450 500 600 700 K1 P+ K2 K3 (55/45/20°C) Length mm Sections 500 1000 1500 2000 2500 3000 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2400 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 15 30 45 60 75 90 12 15 18 21 24 27 30 33 36 42 48 54 60 66 72 78 84 90 18 21 24 27 30 33 36 42 48 54 60 72 12 15 18 21 24 27 30 33 36 42 48 54 60 66 72 78 84 90 12 15 18 21 24 27 30 33 36 42 48 54 60 66 72 78 84 90 UIN 143668 143669 143670 143671 143672 143673 143674 143675 143676 143677 143734 143735 143736 143737 143738 143739 143740 143741 143742 143743 - Heat output Watt Btu/hr 98 122 146 171 195 220 244 293 342 390 128 160 191 223 255 287 319 383 447 510 - 334 416 499 583 666 750 833 1000 1167 1332 436 545 652 761 870 979 1088 1306 1523 1740 - UIN Heat output Watt Btu/hr 143650 131 143651 262 143652 393 143653 524 143654 656 143655 786 143680 156 143681 195 143682 234 143683 272 143684 312 143685 350 143686 389 143687 428 143688 467 143689 545 143690 623 143691 701 143692 779 143693 856 143694 934 143695 1012 143696 1090 143697 1168 ------------143746 202 143747 252 143748 303 143749 353 143750 404 143751 454 143752 505 143753 555 143754 606 143755 707 143756 808 143757 908 143758 1009 143759 1110 143760 1211 143761 1312 143762 1413 143763 1514 143812 230 143813 288 143814 345 143815 403 143816 460 143817 518 143818 575 143819 633 143820 690 143821 805 143822 920 143823 1036 143824 1151 143825 1265 143826 1381 143827 1496 143828 1611 143829 1726 448 894 1342 1789 2237 2683 531 664 798 930 1063 1195 1328 1462 1594 1859 2126 2392 2657 2922 3188 3455 3720 3985 689 861 1033 1205 1378 1550 1722 1894 2066 2411 2755 3100 3444 3788 4133 4477 4822 5166 785 982 1177 1374 1571 1766 1963 2160 2355 2748 3140 3534 3926 4317 4711 5103 5496 5888 UIN 143656 143657 143658 143659 143660 143661 143698 143699 143700 143701 143702 143703 143704 143705 143706 143707 143708 143709 143710 143711 143712 143713 143714 143715 143764 143765 143766 143767 143768 143769 143770 143771 143772 143773 143774 143775 143776 143777 143778 143779 143780 143781 143830 143831 143832 143833 143834 143835 143836 143837 143838 143839 143840 143841 143842 143843 143844 143845 143846 143847 Heat output Watt Btu/hr 192 384 576 767 959 1151 217 272 326 381 435 489 543 598 652 761 869 978 1087 1195 1304 1413 1521 1630 277 347 416 485 554 624 693 762 831 970 1108 1247 1385 1524 1662 1801 1939 2078 315 394 473 552 630 709 788 867 946 1103 1261 1418 1576 1733 1891 2049 2206 2364 655 1309 1965 2618 3274 3927 742 928 1112 1299 1483 1669 1854 2040 2225 2595 2966 3337 3708 4078 4449 4820 5191 5561 945 1183 1418 1655 1891 2128 2363 2601 2836 3309 3781 4254 4727 5199 5672 6145 6618 7090 1075 1344 1613 1882 2151 2420 2688 2957 3226 3764 4302 4839 5377 5915 6452 6990 7528 8065 UIN Heat output Watt Btu/hr UIN Heat output Watt Btu/hr 143662 143663 143664 143665 143666 143667 143716 143717 143718 143719 143720 143721 143722 143723 143724 143725 143726 143727 143728 143729 143730 143731 143732 143733 143782 143783 143784 143785 143786 143787 143788 143789 143790 143791 143792 143793 143794 143795 143796 143797 143798 143799 143848 143849 143850 143851 143852 143853 143854 143855 143856 143857 143858 143859 143860 143861 143862 143863 143864 143865 253 863 506 1726 759 2588 1011 3451 1264 4314 1517 5177 282 963 353 1205 424 1446 494 1687 565 1928 636 2168 706 2409 777 2650 847 2891 988 3372 1130 3855 1271 4337 1412 4818 1553 5300 1694 5781 1836 6264 1977 6746 2118 7227 357 1218 446 1522 535 1826 624 2130 714 2435 803 2739 892 3043 981 3347 1070 3651 1249 4261 1427 4869 1606 5479 1784 6087 1962 6695 2141 7305 2319 7913 2498 8522 2676 9130 404 1378 505 1724 606 2068 707 2413 808 2757 909 3101 1010 3446 1111 3790 1212 4135 1414 4823 1616 5514 1818 6203 2020 6892 2222 7580 2424 8269 2626 8960 2828 9649 3030 10337 3033310 3033320 3053306 3053307 3053308 3053309 3053310 3053311 3053312 3053314 3053316 3053318 3053320 3053324 3063304 3063305 3063306 3063307 3063308 3063309 3063310 3063311 3063312 3063314 3063316 3063318 3063320 3063324 3073305 3073306 3073307 3073308 3073309 3073310 3073311 3073312 3073314 3073316 3073318 3073320 - 695 2370 1389 4741 636 2168 741 2529 847 2891 953 3251 1059 3613 1165 3975 1271 4335 1482 5057 1694 5781 1906 6503 2118 7226 2541 8670 492 1680 615 2100 738 2518 861 2938 984 3358 1107 3778 1230 4198 1353 4618 1477 5038 1723 5878 1968 6716 2215 7556 2461 8396 2953 10076 698 2383 838 2859 977 3335 1118 3813 1257 4289 1397 4765 1536 5242 1676 5718 1955 6672 2235 7624 2514 8579 2793 9531 - Best Sellers - Compact 30 Δt P1 51 EN 442 Certification Data – CETIAT tested in accordance with BS EN 442 P1 450 600 474 619 1.33 1.33 1.03 1.37 9.82 13.00 2.57 3.2 Type Height W/m at 75/65/20 n-coefficients Heated Surface Area (m2/m) Weight (kg/m) Water Contents (l/m) Wall to tap centre (mm) 46 K1 300 450 600 700 509 756 980 1117 1.32 1.31 1.29 1.29 2.09 3.37 4.66 5.51 9.31 14.51 19.70 22.90 1.89 2.57 3.25 3.77 46 51 51 51 P+ 300 450 600 700 745 1055 1345 1530 1.33 1.33 1.34 1.34 2.44 3.84 5.24 6.18 14.29 22.04 29.80 34.50 3.70 5.15 6.60 7.63 51 62 62 62 K2 300 450 600 700 982 1371 1732 1961 1.33 1.33 1.33 1.34 3.51 5.62 7.74 9.15 16.80 25.90 35.00 40.53 3.70 5.15 6.60 7.63 62 73 73 73 K3 300 500 1349 2056 1.31 1.32 5.26 9.49 25.20 43.40 5.40 8.33 73 73 73 600 700 2389 2712 1.32 1.34 11.61 13.72 52.50 60.77 9.80 11.37 73 73 Compact mounting brackets Best Sellers - Compact All dimension in mm. Inches in brackets. Floor mounting brackets available. See page 54. E E D 11 (0.43) 11 (0.43) D 11 (0.43) C C 11 (0.43) 11 (0.43) E D B B B A A A 54 (2.13) 25 (0.98) 14 (0.55) 25 (0.98) 14 (0.55) 61 (2.40) 32 (1.26) 21 (0.83) 32 (1.26) 21 (0.83) P1 K1, P+ and K2 (300mm) Dimensions A B C D E mm 300 65 119 153 185 in 11.81 2.56 4.69 6.02 7.28 mm 450 65 99 269 303 335 in 17.72 2.56 3.90 10.59 11.93 13.19 mm 600 65 99 419 453 485 K1, P+ and K2 (Over 300mm) in 23.62 2.56 3.90 16.50 17.83 19.09 mm 700 65 99 519 553 585 K1, P+, K2 and P1 lug positions in 27.56 2.56 3.90 20.43 21.77 23.03 Pressure drops All dimensions in mm. Inches in brackets. A A A VALUE KV A 0,01 0,1 1 10 1.000 10.000 100 D D B B 1200 (47.24) - 1700 (66.93) LONG 400 (15.75) - 1100 (43.30) LONG 10 = = A PRESSURE DROP kPA A D B 1800 (70.78) - 3000 (118.11) LONG C P1, P+ & K2 Dimensions A B Panel Height mm in 300 11.81 450 17.72 600 23.62 700 27.56 52 mm 133 60 in 5.24 2.36 D mm 155 305 455 555 in 6.10 12.01 17.91 21.95 1 K1 Dimensions mm 400mm 117 A 500 - 3000mm 150 A 400 - 3000mm 60 B 1800 - 3000mm 17 C in 4.61 5.91 2.36 0.67 0,1 1 2 3 10 100 FLOWRATE l/h 1 Type 10 (P1), 11 (K1) 2 Type 21 (P+), 22 (K2) Type 33 (K3) Compact wall mounting information All dimensions in mm. Inches in brackets. P+ Best Sellers - Compact K1 51 (2.01) (R) A { 62 (2.45) (R) A { 83 (3.27) 101 (3.98) 62 (2.44) 73 (2.87) B{ B{ 94 (3.70) 112 (4.41) K2 P1 73 (2.87) (R) A { 124 (4.88) ONLY ONE POSITION POSSIBLE Compact piping options 46 (1.81) 78 (3.07) 84 (3.31) B{ 135 (5.31) Compact bracket position A = Closest to Wall B = Furthest from Wall (R) = Recommended Mounting Position 53 Compact K3 wall mounting and lug information All dimensions in mm. Inches in brackets. Rear elevation Top elevation Side elevation C 180 (7.09) C 158 (6.22) 48 (1.89) 85 (3.35) 60 (2.36) Best Sellers - Compact 85 (3.35) 73 (2.87) L L C 400-1100 133 1200-2400 267 Compact K3 floorstanding brackets All dimensions in mm. Inches in brackets. 120 (4.72) 215 (8.46) 105 (4.13) 43 (1.69) 43 (1.69) 110 (4.33) Floorstanding brackets. L E D D C L 1200 1400 1800 H Number C E 117 150 250 250 250 - - - - L/2+17 L 400 500 1100 1200 1400 1800 2000 3pc 4pc 117 150 250 250 250 - - - - 750 817 850 - - - 817 - - - H Number 600 C D E 700 2pc 3pc 2pc C 2000 3000 300 500 54 400 500 1100 H 2200 2400 2600 2800 3000 5pc 250 750 817 L/2+17 850 Stelrad Compact Vertex K2 (75/65/20°C) Height 1800 2000 2200 Length Sections UIN 400 500 600 700 400 500 600 700 300 400 500 600 700 12 15 18 21 12 15 18 21 9 12 15 18 21 148095 148103 148107 148096 H 148104 148108 148097 148105 148109 Heat output Watts Btu/hr 1146 1719 2006 1248 1872 2184 1356 2034 2373 3910 5865 6844 4258 6387 7452 4627 6940 8097 UIN Heat output Watts Btu/hr 31182204 31182205 31182206 31182207 31202204 31202205 31202206 31202207 31222203 31222204 31222205 31222206 - 1584 5405 1980 6756 2376 8107 2772 9458 1716 5855 2145 7319 2574 8782 3003 10246 1386 4729 1848 6305 2310 7882 2772 9458 - Btu/hr Watts Best Sellers - Compact 50 Δt P2 Btu/hr ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). H Btu/hr 40 Δt P2 K2 (65/55/20°C) Height 1800 2000 2200 Watts 30 Δt Btu/hr Watts P2 Btu/hr K2 (55/45/20°C) Length mm Sections 400 500 600 700 400 500 600 700 300 400 500 600 700 12 15 18 21 12 15 18 21 9 12 15 18 21 UIN 148095 148103 148107 148096 148104 148108 148097 148105 148109 Heat output Watts Btu/hr 857 1286 1500 933 1400 1634 1014 1521 1775 2925 4387 5119 3185 4777 5574 3461 5191 6057 UIN 31182204 31182205 31182206 31182207 31202204 31202205 31202206 31202207 31222203 31222204 31222205 31222206 - Heat output Watts Btu/hr 1185 1467 1777 2073 1284 1604 1925 2246 1037 1382 1728 2073 - 4043 5004 6064 7075 4380 5474 6569 7664 3537 4716 5896 7075 - UIN 148095 148103 148107 148096 148104 148108 148097 148105 148109 Heat output Watts Btu/hr 590 885 1033 643 964 1125 698 1048 1222 2014 3020 3525 2193 3289 3838 2383 3574 4170 UIN 31182204 31182205 31182206 31182207 31202204 31202205 31202206 31202207 31222203 31222204 31222205 31222206 - Heat output Watts Btu/hr 816 1000 1224 1428 884 1105 1326 1547 714 952 1190 1428 - 2783 3412 4175 4871 3015 3769 4523 5277 2435 3247 4059 4871 - EN 442 Certification Data – CETIAT tested in accordance with BS EN 442 Type Height W/m at 75/65/20 n-coefficients Heated Surface Area (m2/m) Weight (kg/m) Water Contents (l/m) Wall to tap centre (mm) 1800 2865 1.31 8.20 71.10 16.20 65 P2 2000 3120 1.30 9.10 78.60 18.00 65 2200 3390 1.30 10.10 87.60 20.10 65 1800 3690 1.33 29.90 105.30 15.90 65 K2 2000 3960 1.33 37.74 116.40 17.70 65 2200 4230 1.33 38.66 126.60 20.10 65 65 55 Compact Vertex mounting brackets Best Sellers - Compact Height mm H2 in H3 H4 mm H4 mm in mm in in 1800 70.87 70 2.75 830 43.89 1590 63.58 2000 78.74 70 2.75 930 47.83 1790 71.46 2200 86.61 70 2.75 1030 51.77 1990 79.33 H3 H2 Compact Vertex wall mounting information All dimensions in mm. Inches in brackets. P2 K2 104(4.09) 77(3.03) 129(5.00) 102 (4.00) 28 (1.10) 28 (1.10) 50 (1.97) LENGTH - 56(2.20) 65 (2.56) 77 (3.03) Comes complete with Stelrad’s class leading safety bracket. 56 LENGTH STR STR2 (75/65/20°C) Height Length mm Sections 645 745 425 625 425 625 825 12 18 12 18 24 STR3 Heat output Watts Btu/hr UIN 140129 - 419 - Heat output Watts Btu/hr UIN 1430 - 140130 - 611 - 2085 - STR4 Heat output Watts Btu/hr UIN 140022 - 475 - 1621 - STR6 STR8 Heat output Watts Btu/hr UIN 140023 - 693 - 2365 - Heat output Watts Btu/hr UIN 140024 3146 922 Best Sellers - STR 50 Δt ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). 40 Δt STR2 (65/55/20°C) STR4 Btu/hr STR6 STR8 Btu/hr Height Length mm Sections 645 745 425 625 425 625 825 12 18 12 18 24 30 Δt STR3 Heat output Watts Btu/hr UIN 140129 - 314 - UIN 140130 - 1070 - STR2 (55/45/20°C) Height Length mm Sections 645 745 425 625 425 625 825 12 18 12 18 24 UIN 140129 - 457 - 1560 - 736 - Btu/hrHeat output Watts Btu/hr UIN 140130 - W 314 - 1074 - Heat output Watts Btu/hr UIN 140022 - STR3 Heat output W Watts Btu/hr 216 - Heat output Watts Btu/hr 355 - 1213 - UIN 140023 - STR4 UIN 140022 - Heat output Watts Btu/hr W 244 - Btu/hr 835 - Heat output Watts Btu/hr 518 - 1769 - UIN 140024 STR6 UIN 140023 - Heat output Watts Btu/hr W 356 - Btu/hr 1217 - Btu/hr Heat output Watts Btu/hr 670 2353 STR8 W Btu/hr UIN 140024 Heat output Watts Btu/hr W 475 Btu/hr 1620 EN 442 Certification Data – CETIAT tested in accordance with BS EN 442 Type Height W/m at 75/65/20 n-coefficients Heated Surface Area (m2/m) Weight (kg/m) Water Contents (l/m) STR2 645 419 1.27 1.86 8.72 1.32 STR3 645 611 1.27 2.79 13.08 1.98 STR4 745 475 1.28 2.21 9.95 1.56 STR6 745 693 1.28 3.31 14.92 2.34 STR8 745 922 1.28 4.41 19.89 3.12 57 STR mounting brackets All dimensions in mm. Inches in brackets. Floor mounting brackets available. See page 42. 68 (2.68) Best Sellers - STR 69 (2.72) C 11 (0.43) D E 11 (0.43) HEIGHT A 25 (0.98) 14 (0.55) 32 (1.26) 21 (0.94) Dimensions mm 700 A 65 B 99 C 519 D 553 E 585 in 27.56 2.56 3.90 20.43 21.77 23.03 B 25 (0.98) mm 600 65 99 419 453 485 in 23.62 2.56 3.90 16.50 17.83 19.09 51 (2.01) 83 (3.26) 62 (2.44) 94 (3.70) STR wall mounting information STR2 Dimensions mm in 425 16.73 A 167 6.57 B 60 2.36 C D 555 21.85 E 140 5.51 58 STR3 mm in 625 24.60 300 11.81 60 2.36 555 21.85 140 5.51 STR4 mm in 425 16.73 167 6.57 60 2.36 555 21.85 140 5.51 STR6 mm in 625 24.60 300 11.81 60 2.36 555 21.85 140 5.51 STR8 mm in 825 32.48 500 19.68 60 2.36 555 21.85 140 5.51 Towel Rail Straight White Height Length mm Max Projection mm UIN 760 1211 1744 500 600 500 600 500 600 100 100 100 100 100 100 148070 148071 148072 148073 148074 148075 Heat output Watts Btu/hr 376 445 576 686 844 1000 Straight Chrome Max Projection mm UIN 100 100 100 100 100 100 147002 147003 147004 147005 142768 142769 1283 1518 1965 2341 2880 3412 Heat output Watts Btu/hr 246 294 379 453 557 667 Curved White Max Projection UIN mm 839 1003 1293 1546 1900 2276 100 100 100 100 100 100 Heat output Watts Btu/hr 147006 376 147007 445 147008 576 147009 686 147010 844 147011 1000 1283 1518 1965 2341 2880 3412 Curved Chrome Max Projection mm UIN 100 100 100 100 100 100 147012 147013 147014 147015 147016 147017 Heat output Watts Btu/hr 246 294 379 453 557 667 839 1003 1293 1546 1900 2276 Best Sellers - Towel Rail 50 Δt (75/65/20°C) ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). EN 442 Certification Data - CETIAT tested in accordance with BS EN 442 Type Straight/Curved Chrome Straight/Curved White No of tubes Height Length Watts at 75/65/20 n-coefficients Heated Surface Area (m²) Weight (kg) Water Contents (l) KM (P/dTn) 760 500 246 1.2545 0.71 6.12 4.41 1.8179 760 600 294 1.2519 0.83 7.06 5.10 2.1949 1211 500 379 1.2757 1 1.11 9.63 6.89 2.5779 1211 H W600 453 1.2726 1.30 11.10 7.97 3.1188 1744 500 Btu/hr 557 1.3015 1.60 13.86 9.80 3.4249 STRAIGHT MODELS A Width (mm) B Height (mm) C Depth (mm) 400 500 600 500 600 500 600 678 760 760 1211 1211 1744 1744 30 30 30 30 30 30 30 70 70 70 70 70 70 70 216 316 416 316 416 316 416 760 500 Watts 376 1.2320 0.71 6.12 4.41 3.0343 760 600 Btu/hr 445 1.2332 0.83 7.06 5.10 3.5743 1211 500 576 1.2528 1.11 9.63 6.89 4.285 1211 600 686 1.2464 1.30 11.10 7.97 5.2327 1744 500 844 1.2783 1.60 13.86 9.80 5.6826 1744 600 1000 1.2625 1.88 15.98 11.40 7.1623 CURVED MODELS D Wall Mounting Positions Tap Centres E F G (mm) (mm) (mm) (mm) 356 456 556 456 556 456 556 1744 600 667 1.2978 1.88 15.98 11.40 4.1610 65-75 65-75 65-75 65-75 65-75 65-75 65-75 D Wall Mounting Positions C Tap Depth Centres E F G (mm) (mm) (mm) (mm) (mm) 56.0 60.0 56.0 60.0 56.0 60.0 456 556 456 556 456 556 110 110 110 110 110 110 236 336 236 336 236 336 40-45 40-45 40-45 40-45 40-45 40-45 59 Straight models Curved models All dimensions in mm. Inches in brackets. All dimensions in mm. Inches in brackets. E F E E F G G G D A D A E E E E Electric element option F F B B U U H W Btu/hr 1 Mini Towel Rail 50 Δt (75/65/20°C) Height 678 Length mm Max Projection mm 400 100 White UIN Chrome Heat output Watts Btu/hr 147000 273 931 Max Projection UIN mm 100 147001 Mini Towel Rail All dimensions in mm. Inches in brackets. Heat output Watts Btu/hr 175 597 (0.98) (0.78) ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). 164 (6.46) 124 (4.88) EN 442 Certification Data CETIAT tested in accordance with BS EN 442 678 (26.69) +3 (0.11) -2 (0.07) Best Sellers - Mini Towel Rail Brackets positions E 328 (12.91) Type White Chrome No of tubes Height Length Watts at 75/65/20 n-coefficients Heated Surface Area (m²) Weight (kg) Water Contents (l) KM (P/dTn) 14 678 400 1.2232 0.51 4.57 3.20 2.2803 14 678 175 1.2535 0.51 4.57 3.20 1.2983 1 60 42+-(1.0) 1.65+-(0.03) Stelrad Caliente Towel Rail 50∆t (75/65/20°C) Single Towel Rail Length mm UIN 450 500 600 750 450 500 600 750 450 500 600 750 450 500 600 750 407501450 407501500 407501600 407501750 401101450 401101500 401101600 401101750 401701450 401701500 401701600 401701750 402001450 402001500 402001600 402001750 755 1199 1791 2013 Heat output Watts Btu/hr 389 431 517 645 615 675 794 972 900 986 1158 1416 1002 1099 1294 1586 Length mm UIN 450 500 600 750 450 500 600 750 450 500 600 750 450 500 600 750 407502450 407502500 407502600 407502750 401102450 401102500 401102600 401102750 401702450 401702500 401702600 401702750 402002450 402002500 402002600 402002750 1327 1471 1764 2201 2098 2303 2709 3316 3071 3364 3951 4831 3419 3750 4415 5411 Heat output Watts Btu/hr 552 616 748 947 868 963 1154 1441 1268 1402 1670 2073 1427 1576 1874 2321 1883 2102 2552 3231 2962 3286 3937 4917 4326 4784 5698 7073 4869 5377 6394 7919 Best Sellers - Caliente Towel Rail Height Double Towel Rail ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). Caliente Towel Rail Single ½” ½” ½” 10 tubes 333 (13.11) 111 (4.37) 10 tubes H = 2013 (79.25) 333 (13.11) ½” ½” A=L-50 (1.96) ½” ½” A=L-50 (1.96) L 18 tubes 629 (24.76) 14 tubes 14 tubes 481 (18.9) 111 (4.37) 111 (4.37) 10 tubes 10 tubes H = 1791 (47.20) 111 (4.37) 111 (4.37) 333 (13.11) 111 (4.37) 481 (18.9) H = 1199 (47.20) H - 163 (6.41) 91 (3.58) 60-80 (2.36)-(3.14) 10 tubes 333 (13.11) ½” 111 (4.37) L-160 (6.29) 4 tubes ½” 333 (13.11) 65-68 (2.55)-(3.34) Caliente Towel Rail piping options Single and Double 111 (4.37) 8 tubes 255 (10.04) ½” 111 (4.37) 50 (1.96) 10 tubes L-160 (6.29) ½” 333 (13.11) All dimensions in mm. Inches in brackets. ½” L-160 (6.29) ½” ½” ½” L ½” ½” A=L-50 (1.96) ½” L Caliente Towel Rail Double 333 (13.11) Bottom, Opposite, End) 2x10 tubes 111 (4.37) H = 2013 (79.25) 333 (13.11) 2x10 tubes 2x10 tubes 2x10 tubes 111 (4.37) 2x8 tubes 259 (10.19) 333 (13.11) 111 (4.37) H = 1791 (70.54) Piping options: BBOE (Bottom, ½”½” A=L-50 (1.96) L ½” ½” ½” ½” A=L-50 (1.96) L ½” 2x17 tubes 592 (23.31) 444 (17.48) 2x13 tubes ½” 2x13 tubes 111 (4.37) 2x10 tubes 333 (13.11) 444 (17.48) H = 1199 (47.21) 111 (4.37) H - 200 (7.87) 128 (5.03) 94-114 (3.7)-(4.48) 333 (13.11) ½” 2x4 tubes 111 (4.37) 80 (3.14) 134-154 (5.27)-(6.06) L-160 (6.29) 111 (4.37) ½” 2x10 tubes 333 (13.11) ½” 50 (1.96) 65-85 (2.55)-(3.34) ½” 111 (4.37) L-160 (6.29) ½” L-160 (6.29) ½” All dimensions in mm. Inches in brackets. ½” ½” ½ “ A=L-50 (1.96) ½” L 61 New Stelrad Curved Caliente Towel Rail Best Sellers - Curved Caliente Towel Rail 50∆t (75/65/20°C) Single Towel Rail Height Length mm UIN 1199 1791 2013 496 595 496 595 496 595 401111496 401111595 401711496 401711595 402011496 402011595 Heat output Watts Btu/hr 675 794 986 1158 1099 1294 2303 2709 3364 3951 3750 4415 ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). Curved Caliente Towel Rail ½” L Curved Caliente Towel Rail piping options Piping options: BBOE (Bottom, Bottom, Opposite, End) 111 (4.37) 8 tubes 10 tubes 111 (4.37) 10 tubes 333 (13.11) H = 2013 (79.25) 333 (13.11) 10 tubes 111 (4.37) 10 tubes 333 (13.11) 111 (4.37) ½” ½” ½” A=L-62 (2.44) L ½” 18 tubes 629 (24.76) 14 tubes 14 tubes ½” 481 (18.94) 111 (4.37) 10 tubes H = 1791 (70.51) 111 (4.37) 333 (13.11) 111 (4.37) H = 1199 (47.21) 481 (18.94) H - 163 (6.42) 91 (3.58) ½” ½” ½” A=L-62 (2.44) 62 333 (13.11) ½” 4 tubes ½” 10 tubes ½” 259 (10.19) 10° 111 (4.37) ±115 (4.52) ±85 (3.34) ½” 50 (1.96) ½” 333 (13.11) All dimensions in mm. Inches in brackets. ½” ½” ½” A=L-62 (2.44) L ½” Stelrad Concord Towel Rail 50∆t (75/65/20°C) Single Height Length mm Tapping centres (A) UIN 731 1186 1511 1771 450 600 450 600 450 600 450 600 400 550 400 550 400 550 400 550 148581 148582 148583 148584 148585 148586 148587 148588 Heat output Watts Btu/hr 342 447 530 694 666 869 777 1010 Best Sellers - Concord Towel Rail 1167 1525 1808 2368 2272 2965 2651 3446 ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). Concord Towel Rail single wall mounting information ½”½” ½” ½”½” ½” 4 tubes 6 tubes 325 (12.79) H = 1771 (69.72) 130 (5.11) 6 tubes 325 (12.79) 8 tubes 5 tubes 7 tubes ½” 130 (5.11) 3 tubes 130 (5.11) 7 tubes ½” 390 (15.35) 130 (5.11) 6 tubes 5 tubes 130 (5.11) H = 1186 (46.69) 130 (5.11) 325 (12.79) 260 (10.24) ½” 390 (15.35) H - 146 (5.75) 73 (2.87) 43-63 (1.69)-(2.48) ½” H = 1511 (59.48) 130 (5.11) L-160 (6.29) 3 tubes ½” L-160 (6.29) 260 (10.24) 70-90 (2.75)-(3.54) ½” ½” 455 (17.91) 50 (1.96) L-160 (6.29) 130 (5.11) 195 (7.67) ½” All dimensions in mm. Inches in brackets. ½” ½”½” A=L-50 (1.96) A=L-50 (1.96) A=L-50 (1.96) L L L ½” Concord Towel Rail piping options Piping options: BBOE (Bottom, Bottom, Opposite, End) 63 Stelrad Esprit Best Sellers - Esprit 50 Δt (75/65/20°C) Straight White Height Length mm Max Projection mm 900 1200 1500 1800 450 550 450 550 450 550 450 550 100 100 100 100 UIN Heat output Watts Btu/hr 148049 405 148050 554 148051 676 148052 1056 1382 1891 2307 3604 Straight Chrome Max Projection mm UIN 100 100 100 100 148053 148054 148055 148056 Curved White Max Heat output Projection Watts Btu/hr mm 316 432 527 824 1078 1474 1799 2812 75 75 75 75 UIN 148057 148058 148059 148060 Curved Chrome Max Heat output Projection Watts Btu/hr mm 452 676 860 1056 1543 2307 2935 3604 75 75 75 75 UIN 148061 148062 148063 148064 ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). Straight EN 442 Certification Data - CETIAT tested in accordance with BS EN 442 Type Height (mm) Width (mm) Btu/h* t50 Watt* t50 Wall to tap centre (mm) Centres from wall (mm) Max. Projection (mm) Weight (mm) Water contents (ltrs) Element watt White 900 450 1382 405 310 80 100 6 1.79 350 1200 450 1891 554 310 80 100 8 2.46 650 1200 550 2307 676 410 80 100 9 2.79 650 Chrome 1800 550 3604 1056 410 80 100 14 4.3 900 900 450 1078 316 310 80 100 6 1.79 350 1200 450 1474 432 310 80 100 8 2.46 350 1200 550 1799 527 410 80 100 9 2.79 350 1800 550 2812 824 410 80 100 14 4.3 900 Curved EN 442 Certification Data - CETIAT tested in accordance with BS EN 442 Type 64 White Chrome Height Width (mm) Btu/h* t50 Watt* t50 Wall to tap centre (mm) Centres from wall (mm) 900 550 1679 492 410 40 1200 550 2307 676 410 40 1500 550 2935 860 410 40 1800 550 3604 1056 410 40 900 550 1311 384 410 40 1200 550 1799 527 410 40 1500 550 2290 671 410 40 1800 550 2812 824 410 40 Max. Projection (mm) Weight (mm) Water contents (ltrs) Element watt 75 6 2.03 350 75 9 2.79 650 75 11 3.54 900 75 14 4.3 900 75 6 2.03 350 75 9 2.79 350 75 11 3.54 650 75 14 4.3 900 Heat output Watts Btu/hr 384 527 671 824 1311 1799 2290 2812 Esprit Straight 1800 1200 550 450 450 Esprit Curved Best Sellers - Esprit 900 550 1800 1500 1200 900 550 550 550 550 Floor mounting brackets available. See page 42. Brackets positions for Straight and Curved Electric element option for Straight and Curved Bracket assembly for Straight and Curved We recommend that you place the brackets between the 2nd and 3rd pipes 80mm from the radiator to the centre of the bracket. 80mm 35mm 30mm 20mm The tapping centres are the width of the radiator minus 60mm. (300mm either side) 30mm The element goes in at the bottom 80mm 65 Stelrad Softline 50 Δt Height Best Sellers - Softline 300 450 600 700 K1 P+ K2 (75/65/20°C) Length mm Sections 500 1000 1500 2000 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 15 30 45 60 12 15 18 21 24 27 30 33 36 42 48 54 60 12 15 18 21 24 27 30 33 36 42 48 54 60 12 15 18 21 24 27 30 33 36 42 48 54 60 UIN 80301105 80301110 80301115 80301120 80451104 80451105 80451106 80451107 80451108 80451109 80451110 80451111 80451112 80451114 80451116 80451118 80451120 80601104 80601105 80601106 80601107 80601108 80601109 80601110 80601111 80601112 80601114 80601116 80601118 80601120 80701104 80701105 80701106 80701107 80701108 80701109 80701110 80701111 80701112 80701114 80701116 80701118 80701120 Heat output Watts Btu/hr 255 509 764 1018 302 378 454 529 605 680 756 832 907 1058 1210 1361 1512 392 490 588 686 784 882 980 1078 1176 1372 1568 1764 1960 447 559 670 782 894 1005 1117 1229 1340 1564 1787 2011 2234 870 1737 2607 3473 1030 1290 1549 1805 2064 2320 2579 2839 3095 3610 4129 4644 5159 1338 1672 2006 2341 2675 3009 3344 3678 4013 4681 5350 6019 6688 1525 1907 2286 2668 3050 3429 3811 4193 4572 5336 6097 6862 7622 UIN 80452110 80452111 80452112 80452114 80452116 80602104 80602105 80602106 80602107 80602108 80602109 80602110 80602111 80602112 80602114 80602116 - Heat output Watts Btu/hr 1055 1161 1266 1477 1688 538 673 807 942 1076 1211 1345 1480 1614 1883 2152 - 3600 3961 4320 5040 5761 1836 2296 2753 3214 3671 4132 4589 5050 5507 6425 7343 - UIN 80302205 80302210 80302215 80302220 80452204 80452205 80452206 80452207 80452208 80452209 80452210 80452211 80452212 80452214 80452216 80452218 80452220 80602204 80602205 80602206 80602207 80602208 80602209 80602210 80602211 80602212 80602214 80602216 80602218 80602220 80702204 80702205 80702206 80702207 80702208 80702209 80702210 80702211 80702212 80702214 80702216 80702218 80702220 Heat output Watts Btu/hr 491 982 1473 1964 548 686 823 960 1097 1234 1371 1508 1645 1919 2194 2468 2742 693 866 1039 1212 1386 1559 1732 1905 2078 2425 2771 3118 3464 784 981 1177 1373 1569 1765 1961 2157 2353 2745 3138 3530 3922 1675 3351 5026 6701 1870 2341 2808 3276 3743 4210 4678 5145 5613 6548 7486 8421 9356 2365 2955 3545 4135 4729 5319 5910 6500 7090 8274 9455 10639 11819 2675 3347 4016 4685 5353 6022 6691 7360 8028 9366 10707 12044 13382 ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). 66 Stelrad Softline Height 300 450 600 700 P+ K2 (65/55/20°C) Length mm Sections 500 1000 1500 2000 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 15 30 45 60 12 15 18 21 24 27 30 33 36 42 48 54 60 12 15 18 21 24 27 30 33 36 42 48 54 60 12 15 18 21 24 27 30 33 36 42 48 54 60 UIN 80301105 80301110 80301115 80301120 80451104 80451105 80451106 80451107 80451108 80451109 80451110 80451111 80451112 80451114 80451116 80451118 80451120 80601104 80601105 80601106 80601107 80601108 80601109 80601110 80601111 80601112 80601114 80601116 80601118 80601120 80701104 80701105 80701106 80701107 80701108 80701109 80701110 80701111 80701112 80701114 80701116 80701118 80701120 Heat output Watts Btu/hr 191 381 571 761 226 283 340 396 453 509 565 622 678 791 905 1018 1131 293 367 440 513 586 660 733 806 880 1026 1173 1319 1466 334 418 501 585 669 752 836 919 1002 1170 1337 1504 1671 651 1299 1950 2598 771 965 1159 1350 1544 1735 1929 2123 2315 2700 3088 3474 3859 1000 1251 1501 1751 2001 2251 2501 2751 3001 3502 4002 4502 5002 1141 1427 1710 1996 2282 2565 2851 3137 3420 3992 4561 5132 5702 UIN 80452110 80452111 80452112 80452114 80452116 80602104 80602105 80602106 80602107 80602108 80602109 80602110 80602111 80602112 80602114 80602116 - Heat output Watts Btu/hr 789 868 947 1105 1337 402 503 604 705 805 906 1006 1107 1207 1408 1610 - 2693 2963 3231 3770 4561 1373 1718 2060 2404 2746 3091 3433 3777 4119 4806 5492 - UIN Heat output Watts Btu/hr 80302205 80302210 80302215 80302220 80452204 80452205 80452206 80452207 80452208 80452209 80452210 80452211 80452212 80452214 80452216 80452218 80452220 80602204 80602205 80602206 80602207 80602208 80602209 80602210 80602211 80602212 80602214 80602216 80602218 80602220 80702204 80702205 80702206 80702207 80702208 80702209 80702210 80702211 80702212 80702214 80702216 80702218 80702220 367 1253 735 2506 1102 3759 1469 5012 410 1399 513 1751 616 2100 718 2450 821 2800 923 3149 1026 3499 1128 3849 1230 4198 1435 4898 1641 5599 1846 6299 2051 6998 518 1769 648 2210 777 2652 907 3093 1037 3537 1166 3979 1296 4420 1425 4862 1554 5303 1814 6189 2073 7072 2332 7958 2591 8841 586 2001 734 2504 880 3004 1027 3504 1174 4004 1320 4505 1467 5005 1613 5505 1760 6005 2053 7006 2347 8009 2640 9009 2934 10010 Best Sellers - Softline 40 Δt K1 67 Stelrad Softline 30 Δt K1 K2 (55/45/20°C) Height 300 Best Sellers - Softline P+ 450 600 700 Length mm Sections 500 1000 1500 2000 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 15 30 45 60 12 15 18 21 24 27 30 33 36 42 48 54 60 12 15 18 21 24 27 30 33 36 42 48 54 60 12 15 18 21 24 27 30 33 36 42 48 54 60 UIN Heat output Watts Btu/hr 80301105 131 80301110 262 80301115 393 80301120 524 80451104 156 80451105 195 80451106 234 80451107 272 80451108 312 80451109 350 80451110 389 80451111 428 80451112 467 80451114 545 80451116 623 80451118 701 80451120 779 80601104 202 80601105 252 80601106 303 80601107 353 80601108 404 80601109 454 80601110 505 80601111 555 80601112 606 80601114 707 80601116 808 80601118 908 80601120 1009 80701104 230 80701105 288 80701106 345 80701107 403 80701108 460 80701109 518 80701110 575 80701111 633 80701112 690 80701114 805 80701116 920 80701118 1036 80701120 1151 448 894 1342 1789 531 664 798 930 1063 1195 1328 1462 1594 1859 2126 2392 2657 689 861 1033 1205 1378 1550 1722 1894 2066 2411 2755 3100 3444 785 982 1177 1374 1571 1766 1963 2160 2355 2748 3140 3534 3926 Heat output Watts Btu/hr UIN 80452110 80452111 80452112 80452114 80452116 80602104 80602105 80602106 80602107 80602108 80602109 80602110 80602111 80602112 80602114 80602116 - 543 598 652 761 920 277 347 416 485 554 624 693 762 831 970 1108 - 1854 2040 2225 2595 3140 945 1183 1418 1655 1891 2128 2363 2601 2836 3309 3781 - Heat output Watts Btu/hr UIN 80302205 80302210 80302215 80302220 80452204 80452205 80452206 80452207 80452208 80452209 80452210 80452211 80452212 80452214 80452216 80452218 80452220 80602204 80602205 80602206 80602207 80602208 80602209 80602210 80602211 80602212 80602214 80602216 80602218 80602220 80702204 80702205 80702206 80702207 80702208 80702209 80702210 80702211 80702212 80702214 80702216 80702218 80702220 253 506 759 1011 282 353 424 494 565 636 706 777 847 988 1130 1271 1412 357 446 535 624 714 803 892 981 1070 1249 1427 1606 1784 404 505 606 707 808 909 1010 1111 1212 1414 1616 1818 2020 863 1726 2588 3451 963 1205 1446 1687 1928 2168 2409 2650 2891 3372 3855 4337 4818 1218 1522 1826 2130 2435 2739 3043 3347 3651 4261 4869 5479 6087 1378 1724 2068 2413 2757 3101 3446 3790 4135 4823 5514 6203 6892 EN 442 Certification Data – CETIAT tested in accordance with BS EN 442 Type Height W/m at 75/65/20 n-coefficients Heated Surface Area (m2/m) Weight (kg/m) Water Contents (l/m) Wall to tap centre (mm) 68 K1 P+ K2 300 509 1.32 2.09 9.31 1.89 450 756 1.31 3.37 14.51 2.57 600 980 1.29 4.66 19.70 3.25 700 1117 1.29 5.51 22.90 3.77 450 1055 1.33 3.84 22.04 5.15 600 1345 1.34 5.24 29.80 6.60 300 982 1.33 3.51 16.80 3.70 450 1371 1.33 5.62 25.90 5.15 600 1732 1.33 7.74 35.00 6.60 700 1961 1.34 9.15 40.53 7.63 54 54 54 64 64 64 64 72 72 72 17 (0.66) Softline mounting brackets 31 (1.22) All dimensions in mm. Inches in brackets. 17 (0.66) J Best Sellers - Softline D C G 12 (0.47) I H 31 (1.22) D 15 (0.59) 15 (0.59) 13 (0.51) 13 (0.51) A A B B E E F G H J 12 (0.47) H450-600-700 Height mm 300 16 44 144 77 125 155 173 155 A B C D E F G H I J in 11.81 0.63 1.73 5.67 3.03 4.92 6.10 6.81 6.10 mm 450 16 44 266 294 77 107 275 305 323 305 in 17.72 0.63 1.73 10.47 11.57 3.03 4.21 10.83 12.01 12.72 12.01 mm 600 16 44 416 444 77 107 425 455 473 455 in 23.62 0.63 1.73 16.38 17.48 3.03 4.21 16.73 17.91 18.62 17.91 mm 700 16 44 516 544 77 107 525 555 573 555 in 27.56 0.63 1.73 20.31 21.42 3.03 4.21 20.67 21.85 22.56 21.85 Pressure drops K1, P+ and K2 lug positions All dimensions in mm. Inches in brackets. A 85 (3.35) 60 (2.36) A L P+/K2 85 (3.35) B K1 D C 85 (3.35) 85 (3.35) 60 (2.36) C L K1 L 400 500 - 1100 1200 - 1600 1800 - 2000 A mm 117 150 283 283 B in - mm in (L/2) +17 C mm 133 133 267 267 TYPE P+ / K2 D in mm in (L/2) 69 Softline wall mounting information All dimensions in mm. Inches in brackets. Floor mounting brackets available. See page 42. Best Sellers - Softline K1 86 (3.39) 102 (4.02) 61 (2.40) 77 (3.03) 54 (2.13) 70 P+ 64 (2.52) K2 125 (4.92) 100 (3.94) 72 (2.83) Designer Stelrad’s designer ranges provide additional options to make a real style statement in any commercial or domestic environment. Compact with Style Range Classic Column Range • Stunning looks and value, bridging the gap between • At home in either traditional or modern environments • Height options from 200mm up to 2200mm • Standard model supplied in RAL 9016, also available and lengths from 400mm to 2000mm in a wide choice of other RAL or BS colour options to harmonise with the boldest or most neutral of decors • Horizontal, Vertical and Lo-Line options • 7 height options, six vertical and a choice of two, three available to suit any space • For colour options refer to page 146 Planar Range • Supplied fully assembled, and easy to install • Every model comes with a directional air vent to direct waterflow during venting • Choice of four heights and 74 models in the most popular sizes • Wide range of outputs with outstanding heating performance or four columns to provide a versatile sizing flexibility ideal for use in a minimalist project, or for applications where work space is restricted • For colour options refer to page 147 Swing Designer standard radiators and more expensive models • Stylish curved cover • High output vertical models where space is at a premium • Choice of 2 heights and 3 lengths • For colour options refer to page 146 • For colour options refer to page 146 Caliente Concord Range • Stylish tube on tube high output design • The Stelrad Concord incorporates flat oval precision • Vertical, horizontal, single and double tube versions tubes, pressure welded with a 4mm air gap to symmetric water channels. Flat oval steel tubes 70mm x 8mm. Water channel tubing 37mm x 32mm • Concord Plane - slim flat horizontal tubes • Concord Lo-Line - Despite having only two panels the Lo-Line offers performance which belies its size • Concord Vertical - The same highly engineered tubes in a vertical model • Concord Slimline - Subtle visual appeal displaying the slim form of the tubes • 15 models in three heights and a variety of widths • High quality construction and paint finish rounded edges • Available in white (RAL 9016) only Excel • Floor or wall mounted • Available in 3 sizes • Optional outputs • Sophisticated black as standard (RAL 9005) • All models available in a wide range of height, width and output options • 2 x 15mm connections BOE are fitted as standard. 4 x 15mm connections available as an optional extra, prices available on request • For colour options refer to page 147 71 Arc & Wave Ellipse • Precision curved fine tubes • Range of sizes and outputs • Available in 3 sizes and 3 heat output options • Choice of outward or inward facing columns • Large range of colour options available Vistaline (see page 147) • Range of sizes and outputs • Available with additional row of tubes for greater heat output • Large range of colour options available • Available in 3 lengths and 3 output options • Incorporates towel warmer • Cold metallic grey (BR 0007) Designer (see page 147) Optia For further information and advice call 0844 543 6200 72 Stelrad Compact with Style Range Btu/hr Height 300 500 600 K2 (75/65/20°C) Length mm Sections 500 1000 1400 2000 400 600 800 1000 1200 1400 1600 1800 2000 400 600 800 1000 1200 1400 1600 1800 2000 15 30 42 60 12 18 24 30 36 42 48 54 60 12 18 24 30 36 42 48 54 60 UIN 7431105 7431110 7431114 7431120 7451104 7451106 7451108 7451110 7451112 7451114 7451116 7451118 7451120 7461104 7461106 7461108 7461110 7461112 7461114 7461116 7461118 7461120 Heat output Watts Btu/hr 235 469 658 940 298 448 597 746 895 1044 1194 1343 1492 348 522 696 870 1044 1218 1392 1566 1740 802 1600 2245 3207 1017 1529 2037 2545 3054 3562 4074 4582 5091 1187 1781 2375 2968 3562 4156 4750 5343 5937 Btu/hr Btu/hr UIN Heat output Watts Btu/hr 7432205 7432210 7432214 7432220 7452204 7452206 7452208 7452210 7452212 7452214 7452216 7452218 7452220 7462204 7462206 7462208 7462210 7462212 7462214 7462216 7462218 7462220 449 1532 898 3064 1257 4289 1796 6128 555 1894 833 2842 1110 3787 1388 4736 1666 5684 1943 6630 2221 7578 2498 8523 2776 9472 640 2184 961 3279 1281 4371 1601 5463 1921 6554 2241 7646 2562 8742 2882 9833 3202 10925 Designer - Compact with Style 50 Δt 7 K1 ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). 40 Δt Height 300 500 600 K1 K2 (65/55/20°C) Length mm 500 1000 1400 2000 400 600 800 1000 1200 1400 1600 1800 2000 400 600 800 1000 1200 1400 1600 1800 2000 Sections UIN 15 30 42 60 12 18 24 30 36 42 48 54 60 12 18 24 30 36 42 48 54 60 7431105 7431110 7431114 7431120 7451104 7451106 7451108 7451110 7451112 7451114 7451116 7451118 7451120 7461104 7461106 7461108 7461110 7461112 7461114 7461116 7461118 7461120 Heat output Watts Btu/hr 176 351 491 702 223 335 447 558 669 781 893 1005 1116 260 390 521 651 781 911 1041 1171 1302 600 1197 1677 2394 761 1143 1524 1904 2284 2664 3047 3428 3808 888 1332 1776 2220 2664 3109 3553 3997 4441 UIN 7432205 7 7432210 7432214 7432220 7452204 7452206 7452208 7452210 7452212 7452214 7452216 7452218 7452220 7462204 7462206 7462208 7462210 7462212 7462214 7462216 7462218 7462220 Heat output Watts Btu/hr 335 671 940 1343 415 623 830 1038 1246 1453 1661 1869 2076 479 719 958 1198 1437 1676 1916 2156 2395 1148 2291 3208 4583 1416 2126 2833 3542 4252 4959 5668 6375 7085 1633 2453 3269 4086 4903 5719 6539 7355 8172 73 Stelrad Compact with Style Range 30 Δt Height 300 500 Designer - Compact with Style 600 K1 K2 (55/45/20°C) Length mm 500 1000 1400 2000 400 600 800 1000 1200 1400 1600 1800 2000 400 600 800 1000 1200 1400 1600 1800 2000 Sections Heat output Watts Btu/hr UIN 15 30 42 60 12 18 24 30 36 42 48 54 60 12 18 24 30 36 42 48 54 60 7431105 7431110 7431114 7431120 7451104 7451106 7451108 7451110 7451112 7451114 7451116 7451118 7451120 7461104 7461106 7461108 7461110 7461112 7461114 7461116 7461118 7461120 121 242 338 483 153 231 307 384 461 538 615 692 768 179 269 358 448 538 627 717 806 896 413 824 1154 1648 524 787 1049 1311 1573 1834 2098 2360 2622 611 917 1223 1529 1834 2140 2446 2752 3057 UIN Heat output Watts Btu/hr 7432205 7432210 7432214 7432220 7452204 7452206 7452208 7452210 7452212 7452214 7452216 7452218 7452220 7462204 7462206 7462208 7462210 7462212 7462214 7462216 7462218 7462220 788 231 462 1577 647 2208 924 3155 975 286 429 1464 572 1950 715 2439 858 2927 1001 3414 1144 3903 1286 4389 1430 4878 330 1125 495 1689 660 2251 825 2813 Btu/hr 989 3376 1154 3938 1319 4502 1484 5064 1649 5626 EN 442 Certification Data – CETIAT tested in accordance with BS EN 442 Type Height W/m at 75/65/20 n-coefficients Heated Surface Area (m2/m) Weight (kg/m) Water Contents (l/m) Wall to tap centre (mm) Floor standing 300 470 1.26 2.09 14.13 1.81 54 - K1 500 746 1.28 3.80 20.23 2.77 54 - P+ 200 483 1.31 1.51 12.14 2.64 76 600 870 1.28 4.66 24.27 3.23 54 - K2 200 614 1.29 2.10 13.15 2.70 76 300 898 1.30 3.51 19.30 3.10 76 500 1388 1.31 6.33 32.03 5.17 76 600 1601 1.31 7.74 38.40 6.20 76 Stelrad Compact with Style Lo-Line K1 50 Δt Height Length mm Sections 50 500 1000 1400 2000 15 30 42 60 ∆t (75/65/20°C) K2 Heat output Watts Btu/hr UIN - - - UIN 7422205 7422210 7422214 7422220 7 Heat output Watts Btu/hr 307 614 860 1228 1047 2095 2934 4190 ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). 40 ∆t (65/55/20°C) 30 ∆t (55/45/20°C) 74 500 1000 1400 2000 15 30 42 60 - - - 7422205 7422210 7422214 7422220 7 230 459 643 919 784 1567 2195 3134 500 1000 1400 2000 15 30 42 60 - - - 7422205 7422210 7422214 7422220 7 158 316 443 632 539 1079 1511 2158 Stelrad Compact with Style Vertical 50 Δt P2 (75/65/20°C) Height Length mm Sections 1600 300 500 600 300 400 500 600 700 300 400 500 600 700 300 400 500 600 9 15 18 9 12 15 18 21 9 12 15 18 21 9 12 15 18 1800 2000 2200 K2 UIN 148140 148148 148152 148141 148149 148153 148142 148150 148154 148143 148151 148155 Heat output Watts Btu/hr 693 1155 1386 760 1266 1519 824 1374 1649 887 1479 1775 2365 3941 4729 2593 4320 5183 2811 4688 5626 3026 5046 6056 Heat output Watts Btu/hr UIN 32182204 32182205 32182206 32182207 32202204 32202205 32202206 32202207 32222203 32222204 32222205 32222206 1476 1845 2214 2583 1588 1980 2376 2772 1269 1692 2115 2538 5036 6295 7554 8813 5405 6756 8107 9458 4330 5773 7216 8660 40 Δt P2 Length mm 1600 300 500 600 300 400 500 600 700 300 400 500 600 700 300 400 500 600 2000 2200 K2 (65/55/20°C) Height 1800 Designer - Compact with Style ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). Sections UIN 9 15 18 9 12 15 18 21 9 12 15 18 21 9 12 15 18 148140 148148 148152 148141 148149 148153 148142 148150 148154 148143 148151 148155 Heat output Watts Btu/hr 518 H863 1036 568 947 1136 616 1028 1233 663 1106 1328 1769 2947 3537 1940 3231 3877 2103 3507 4210 2263 3774 4530 UIN Heat output Watts Btu/hr 32182204 32182205 32182206 32182207 32202204 32202205 32202206 32202207 32222203 32222204 32222205 32222206 - Btu/hr1104 3767 1380 4709 1656 5651 1932 6592 1188 4043 1481 5053 1777 6064 2073 7075 949 3239 1266 4318 1582 5398 1898 6477 75 Stelrad Compact with Style Vertical P2 30 Δt (55/45/20°C) Height Length mm Sections 1600 300 500 600 300 400 500 600 700 300 400 500 600 700 300 400 500 600 9 15 18 9 12 15 18 21 9 12 15 18 21 9 12 15 18 1800 2000 Designer - Compact with Style 2200 UIN 148140 148148 148152 148141 148149 148153 148142 148150 148154 148143 148151 148155 K2 Heat output Watts Btu/hr 356 594 713 391 652 782 424 708 849 457 762 914 1217 2029 2435 1335 2225 2669 1448 2414 2897 1558 2599 3119 Heat output Watts Btu/hr UIN 32182204 32182205 32182206 32182207 32202204 32202205 32202206 32202207 32222203 32222204 32222205 32222206 760 950 1140 1330 818 1020 1224 1428 654 871 1089 1307 2594 3242 3890 4539 2784 3479 4175 4871 2230 2973 3716 4460 EN 442 Certification Data – CETIAT tested in accordance with BS EN 442 Type Height W/m at 75/65/20 n-coefficients Heated Surface Area (m2/m) Weight (kg/m) Water Contents (l/m) Wall to tap centre (mm) 76 P2 1600 2310 1.27 7.33 77.70 14.10 65 1800 2532 1.27 8.25 86.70 16.20 65 K2 2000 2748 1.27 9.17 95.40 18.30 65 2200 2958 1.27 10.09 105.60 20.10 65 1600 3420 1.32 28.99 94.20 14.10 77 1800 3690 1.32 29.90 105.30 15.90 77 2000 3960 1.33 37.74 116.40 17.70 77 2200 4230 1.33 38.66 126.60 20.10 77 Compact with Style 300mm, 500mm & 600mm wall mounting information All dimensions in mm. Inches in brackets. Floor mounting brackets available. See page 42. K1 K2 Compact with Style piping options 63 (2.48) 54 (2.13) 88 (3.46) Designer - Compact with Style 102 (4.02) 76 (2.99) 127 (5.00) K1 and K2 lug positions Pressure drops All dimensions in mm. Inches in brackets. A Length 400mm 500 - 1000mm 1200 - 16000mm 1800 - 2000mm *K1 + 17mm K1 K2 mm in mm in 117 4.61 133 5.24 150 5.91 133 5.24 283 11.14 267 10.51 3rd lug in rad. centre* 77 Compact with Style Lo-Line panel information Compact with Style piping options All dimensions in mm. Inches in brackets. Designer - Compact with Style 102 (4.02) 200 (7.87) P+ and K2 Compact with Style Lo-Line floor mounting information 150 (5.91) All dimensions in mm. Inches in brackets. Floor mounting bracket comes as standard (200mm only) 78 Compact with Style Vertical mounted brackets and piping options H4 in 63 70.9 78.7 86.6 H2 mm in 70 2.75 70 2.75 70 2.75 70 2.75 H3 mm in 730 36.02 830 43.89 930 47.83 1030 51.77 H4 mm in 1390 55.71 1590 63.58 1790 71.46 1990 79.33 H3 H2 Designer - Compact with Style Height mm 1600 1800 2000 2200 Compact with Style Vertical wall mounting information All dimensions in mm. Inches in brackets. P2 K2 104 (4.09) ( 77 (3.03) 129 (5.00) 102 (4.00) 28 (1.10) 28 (1.10) The Stelrad STARS Heatloss Calculator contains an inbuilt U value calculator. Save time and effort by using 28 (1.10) 28 (1.10) 50 (1.97) 56 (2.20) 65 (2.56) 77 (3.03) the Stelrad STARS program ( the perfect solution for accurate sizing and design flexibility. Visit www.starsapp.co.uk 79 Stelrad Planar Range K1 50∆t (75/65/20°C) Height Length mm Sections UIN 300 500 1000 1400 2000 400 600 800 1000 1200 1400 1600 1800 2000 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 400 600 800 1000 1200 1400 1600 1800 2000 15 30 42 60 12 18 24 30 36 42 48 54 60 12 18 24 30 36 42 48 54 60 66 72 78 84 90 12 18 24 30 36 42 48 54 60 66 72 78 84 90 12 18 30 36 42 48 54 60 66 140900 140901 140902 140903 140908 140909 140910 140911 140912 140913 140914 140915 140916 140926 140927 140928 140929 140930 140931 140932 140933 140934 141100 141101 141102 141103 141104 140944 140945 140946 140947 140948 140949 140950 140951 140952 141110 141111 141112 141113 141114 140974 140975 140976 140977 140978 140979 140980 140981 140982 400 Designer - Planar 500 600 700 K2 Heat output Watts Btu/hr 235 469 657 938 250 376 501 626 751 876 1002 1127 1252 310 464 619 774 929 1084 1238 1393 1548 1702 1858 2013 2168 2321 364 547 729 911 1093 1275 1458 1640 1822 2005 2186 2368 2550 2734 415 623 830 1038 1246 1453 1661 1868 2076 802 1600 2242 3200 853 1283 1709 2136 2562 2989 3419 3845 4272 1058 1583 2112 2641 3170 3699 4224 4753 5282 5812 6341 6871 7394 7924 1242 1866 2487 3108 3729 4350 4975 5596 6217 6840 7461 8081 8708 9329 1416 2126 2832 3542 4251 4958 5667 6374 7083 UIN 140904 140905 140906 140907 140917 140918 140919 140920 140921 140922 140923 140924 140925 140935 140936 140937 140938 140939 140940 140941 140942 140943 141105 141106 141107 141108 141109 140953 140954 140955 140956 140957 140958 140959 140960 140961 141115 141116 141117 141118 141119 140983 140984 140985 140986 140987 140988 140989 140990 140991 Heat output Watts Btu/hr 465 929 1301 1858 471 706 942 1177 1412 1648 1883 2119 2354 564 847 1129 1411 1693 1975 2258 2540 2822 3105 3386 3668 3950 4234 654 980 1307 1634 1961 2288 2614 2941 3268 3594 3922 4249 4576 4901 739 1095 1460 1824 2189 2554 2919 3284 3649 1587 3170 4439 6339 1607 2409 3214 4016 4818 5623 6425 7230 8032 1924 2890 3852 4814 5777 6739 7704 8666 9629 10595 11556 12518 13486 14448 2231 3344 4459 5575 6691 7807 8919 10035 11150 12269 13386 14502 15613 16729 2521 3736 4980 6224 7469 8713 9960 11205 12449 Please note: All products over 2 metres wide will take 6 weeks to be delivered from date of order. When this product is ordered it cannot be cancelled. ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). 80 Stelrad Planar Range 40∆t (65/55/20°C) Height Length mm Sections UIN 300 500 1000 1400 2000 400 600 800 1000 1200 1400 1600 1800 2000 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 400 600 800 1000 1200 1400 1600 1800 2000 15 30 42 60 12 18 24 30 36 42 48 54 60 12 18 24 30 36 42 48 54 60 66 72 78 84 90 12 18 24 30 36 42 48 54 60 66 72 78 84 90 12 18 30 36 42 48 54 60 66 140900 140901 140902 140903 140908 140909 140910 140911 140912 140913 140914 140915 140916 140926 140927 140928 140929 140930 140931 140932 140933 140934 141100 141101 141102 141103 141104 140944 140945 140946 140947 140948 140949 140950 140951 140952 141110 141111 141112 141113 141114 140974 140975 140976 140977 140978 140979 140980 140981 140982 400 500 600 700 K2 Heat output Watts Btu/hr 176 351 491 702 187 281 375 468 562 655 749 843 936 232 347 463 579 695 811 926 1042 1158 1274 1390 1505 1621 1737 272 409 545 681 818 954 1091 1227 1363 1499 1635 1772 1908 2044 310 466 621 776 932 1087 1242 1397 1553 600 1197 1677 2394 638 960 1279 1598 1917 2236 2557 2876 3195 791 1184 1580 1975 2371 2767 3160 3555 3951 4346 4742 5135 5531 5926 929 1396 1861 2325 2790 3254 3721 4186 4650 5115 5579 6046 6511 6975 1059 1590 2118 2649 3180 3708 4239 4767 5298 UIN 140904 140905 140906 140907 140917 140918 140919 140920 140921 140922 140923 140924 140925 140935 140936 140937 140938 140939 140940 140941 140942 140943 141105 141106 141107 141108 141109 140953 140954 140955 140956 140957 140958 140959 140960 140961 141115 141116 141117 141118 141119 140983 140984 140985 140986 140987 140988 140989 140990 140991 Heat output Watts Btu/hr 348 695 973 1390 352 528 705 880 1056 1233 1408 1585 1761 422 634 844 1055 1266 1477 1689 1900 2111 2322 2533 2744 2955 3166 489 733 978 1222 1467 1711 1955 2200 2444 2689 2934 3178 3422 3667 546 819 1092 1365 1637 1910 2184 2456 2729 1187 2371 3320 4742 1202 1802 2404 3004 3604 4206 4806 5408 6008 1439 2162 2881 3601 4321 5041 5763 6483 7202 7922 8642 9364 10084 10803 1669 2501 3336 4170 5005 5839 6671 7506 8341 9175 10010 10842 11676 12511 1861 2794 3725 4656 5586 6517 7450 8381 9312 Designer - Planar K1 Please note: All products over 2 metres wide will take 6 weeks to be delivered from date of order. When this product is ordered it cannot be cancelled. 81 Stelrad Planar Range K1 30∆t (55/45/20°C) Height Length mm Sections UIN 300 500 1000 1400 2000 400 600 800 1000 1200 1400 1600 1800 2000 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 400 600 800 1000 1200 1400 1600 1800 2000 15 30 42 60 12 18 24 30 36 42 48 54 60 12 18 24 30 36 42 48 54 60 66 72 78 84 90 12 18 24 30 36 42 48 54 60 66 72 78 84 90 12 18 30 36 42 48 54 60 66 140900 140901 140902 140903 140908 140909 140910 140911 140912 140913 140914 140915 140916 140926 140927 140928 140929 140930 140931 140932 140933 140934 141100 141101 141102 141103 141104 140944 140945 140946 140947 140948 140949 140950 140951 140952 141110 141111 141112 141113 141114 140974 140975 140976 140977 140978 140979 140980 140981 140982 400 Designer - Planar 500 600 700 K2 Heat output Watts Btu/hr 121 242 338 483 129 194 258 322 387 451 516 580 645 160 239 319 399 478 558 638 717 797 877 957 1036 1116 1196 187 282 375 469 563 657 751 845 938 1032 1126 1220 1314 1407 214 321 427 535 642 748 855 962 1069 413 824 1154 1648 439 661 880 1100 1320 1539 1761 1980 2200 545 815 1088 1360 1632 1905 2175 2448 2720 2992 3265 3535 3808 4080 640 961 1281 1601 1921 2240 2562 2882 3202 3521 3841 4163 4483 4802 729 1095 1458 1824 2189 2553 2919 3282 3648 UIN 140904 140905 140906 140907 140917 140918 140919 140920 140921 140922 140923 140924 140925 140935 140936 140937 140938 140939 140940 140941 140942 140943 141105 141106 141107 141108 141109 140953 140954 140955 140956 140957 140958 140959 140960 140961 141115 141116 141117 141118 141119 140983 140984 140985 140986 140987 140988 140989 140990 140991 Heat output Watts Btu/hr 239 478 670 957 243 364 485 606 727 849 970 1091 1212 290 436 581 727 872 1017 1163 1308 1453 1599 1744 1890 2035 2180 337 505 673 842 1010 1178 1346 1515 1683 1851 2020 2188 2356 2525 381 564 752 939 1127 1332 1503 1691 1879 817 1632 2286 3265 828 1241 1655 2068 2481 2896 3309 3723 4136 991 1488 1984 2479 2975 3470 3968 4463 4959 5454 5950 6447 6943 7438 1149 1722 2297 2871 3446 4020 4593 5168 5742 6317 6892 7465 8039 8614 1282 1924 2565 3206 3846 4487 5130 5770 6411 Please note: All products over 2 metres wide will take 6 weeks to be delivered from date of order. When this product is ordered it cannot be cancelled. 82 Stelrad Planar Range EN 442 Certification Data - CETIAT tested in accordance with BS EN 442 Type K1 Height W/m at 75/65/20 n-coefficients Heated Surface Area (m²/m) Weight (kg/m) Water contents (l/m) Wall to tap centre (mm) K2 300 400 500 600 469 629 774 911 1.30 1.29 1.28 1.27 2.09 2.95 3.80 4.66 11.88 16.13 20.39 24.65 1.89 2.34 2.80 3.25 54 54 54 54 700 1038 1.27 5.51 28.91 3.77 54 300 929 1.29 3.51 19.60 3.70 76 400 500 600 700 1177 1411 1634 1848 1.30 1.31 1.32 1.33 4.92 6.33 7.74 9.15 26.40 33.20 40.00 46.80 4.67 5.63 6.60 7.63 76 76 76 76 Stelrad Planar Vertical Height Length mm Sections 400 500 600 700 400 500 600 700 400 500 600 700 12 15 18 21 12 15 18 21 12 15 18 21 1800 2000 2200 50 Δt (75/65/20°C) UIN Heat output Watts Btu/hr 30182204 30182205 30182206 30182207 30202204 30202205 30202206 30202207 30222204 30222205 30222206 30222207 1476 5036 1845 6295 2214 7554 2583 8813 1584 5405 1980 6756 2376 8107 2772 9458 1692 5773 2115 7216 2538 8660 2961 10103 Designer - Planar K2 ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). K2 Height Length mm Sections 400 500 600 700 400 500 600 700 400 500 600 700 12 15 18 21 12 15 18 21 12 15 18 21 1800 2000 2200 40 Δt (65/55/20°C) 30 Δt (55/45/20°C) UIN 30182204 30182205 30182206 30182207 30202204 30202205 30202206 30202207 30222204 30222205 30222206 30222207 Heat output Watts Btu/hr 1104 1380 1656 1932 1185 1481 1777 2073 1266 1582 1898 2215 3767 4709 5651 6592 4043 5053 6064 7075 4318 5398 6477 7557 UIN 30182204 30182205 30182206 30182207 30202204 30202205 30202206 30202207 30222204 30222205 30222206 30222207 Heat output Watts Btu/hr 760 950 1140 1330 816 1020 1224 1428 871 1089 1307 1525 2594 3242 3890 4539 2783 3479 4175 4871 2973 3716 4460 5203 EN 442 Certification Data – CETIAT tested in accordance with BS EN 442 Type Height W/m at 75/65/20 n-coefficients Heated Surface Area (m2/m) Weight (kg/m) Water Contents (l/m) Wall to tap centre (mm) 1800 3690 1.32 29.90 105.30 15.90 77 K2 2000 3960 1.33 37.74 116.40 17.70 77 2200 4230 1.33 38.66 126.60 20.10 77 83 Planar Horizontal mounting brackets 17 (0.66) 31 (1.22) All dimensions in mm. Inches in brackets. Floor mounting brackets available. See page 42. 17 (0.66) H I 31 (1.22) C G D 12 (0.47) D A A B B E E F G H I 12 (0.47) 15 (0.59) 15 (0.59) K1 and K2 (300mm) Designer - Planar Dimensions mm in 300 11.81 A 16 0.62 B 44 1.73 C D 144 5.66 E 77 3.03 F G 125 4.92 H 155 6.10 I 173 6.81 mm 400 16 44 216 244 77 107 225 255 273 in 15.75 0.62 1.73 8.50 9.60 3.03 4.21 8.85 10.03 10.74 mm 500 16 44 316 344 77 107 325 355 373 K1 and K2 (400, 500 & 600mm) in 19.69 0.62 1.73 12.44 13.54 3.03 4.21 12.79 13.97 14.68 mm 600 16 44 416 444 77 107 425 455 473 in 23.62 0.62 1.73 16.37 17.48 3.03 4.21 16.73 17.91 18.62 L E D D C L 400 500 1100 1200 1400 1800 H H Number 300 C E 117 150 250 250 250 - - - - L/2+17 L 400 500 1100 1200 1400 1800 2000 3pc 4pc 117 150 250 250 250 - - - - 750 817 850 - - - 817 - - - 500 H Number 600 C D E 700 2pc 3pc 2pc C 2000 3000 2200 2400 2600 2800 3000 5pc 250 750 817 850 L/2+17 K1 and K2 lug positions All dimensions in mm. Inches in brackets. A A A D D B B 400 (15.75) - 1100 (43.30) LONG A 1200 (47.24) - 1700 (66.93) LONG = = D B 1800 (70.78) - 2000 (78.74) LONG 84 A C Dimensions A 400mm A 500 - 1100mm A 1200 - 2000mm B All C 1800 - 3000mm K1 mm in 117 4.61 150 5.91 283 11.14 60 2.36 17 0.67 Dimensions A 400 - 1100mm A 1200 - 2000mm B All K2 mm in 133 5.24 267 10.50 60 2.36 A Panel Height mm in 300 11.81 400 15.75 500 19.69 600 23.62 D mm 155 255 355 455 in 6.10 10.04 13.98 17.93 Planar wall mounting information All dimensions in mm. Inches in brackets. K1 K2 76 (2.99) 54 (2.13) (R) A { (R) A { Designer - Planar 125 (4.92) 86 (3.38) 90 (3.54) 68 (2.68) B{ B{ 139 (5.47) 100 (3.94) Planar bracket position A = Closest to Wall B = Furthest from Wall (R) = Recommended Mounting Position Pressure drops VALUE KV 0,01 0,1 1 10 1.000 10.000 100 PRESSURE DROP kPA 10 1 0,1 1 2 3 10 100 FLOWRATE l/h 1 Type 10 (P1), 11 (K1) 2 Type 21 (P+), 22 (K2) Type 33 (K3) 85 Planar Vertical mounting brackets Planar piping options H4 H3 H2 Designer - Planar Height mm in 1800 70.87 2000 78.74 2200 86.61 H2 mm 70 70 70 in 2.75 2.75 2.75 H3 mm in 830 43.89 930 47.83 1030 51.77 H4 mm in 1590 63.58 1790 71.46 1900 79.33 Planar Vertical wall mounting information All dimensions in mm. Inches in brackets. 129 (5.00) 102 (4.00) 28 (1.10) 28 (1.10) 28 (1.10) 28 (1.10) 50 (1.97) 77 (3.03) LENGTH - 56 (2.20) LENGTH Comes complete with Stelrad’s class leading safety bracket. 86 Stelrad Concord Range 50 Δt (75/65/20°C) Height 144 292 440 588 736 Length mm Elements 800 1000 1200 1400 1600 1800 2000 2200 800 1000 1200 1400 1600 1800 2000 2200 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 2 2 2 2 2 2 2 2 4 4 4 4 4 4 4 4 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 UIN 148308 148309 148310 148311 148312 148313 148314 148315 148316 148317 148318 148319 148320 148321 148322 148323 - Single Heat output Watts Btu/hr UIN 1809 2263 2717 3167 3621 4071 4525 4979 3065 3829 4594 5362 6126 6894 7658 8423 - 148346 148347 148348 148349 148350 148351 148352 148353 148354 148355 148356 148357 148358 148359 148360 148361 148362 148363 148364 148365 148366 148367 148368 148369 148370 148371 148372 148373 148374 148375 148376 148377 148378 148379 148380 148381 148382 148383 148384 148385 148386 148387 148388 148389 148390 148391 148392 148393 148394 148395 148396 530 663 796 928 1061 1193 1326 1459 898 1122 1346 1571 1795 2020 2244 2468 - Heat output Watts Btu/hr 382 458 535 611 688 764 840 917 1070 1222 1375 1528 1681 1834 1986 2139 2292 500 599 699 799 899 999 1099 1199 1399 1598 1798 1998 2198 2398 2597 2797 2997 606 727 848 970 1091 1212 1333 1454 1697 1939 2182 2424 2666 2909 3151 3394 3636 1303 1563 1826 2085 2348 2607 2867 3130 3651 4170 4692 5215 5736 6258 6778 7298 7822 1706 2044 2385 2726 3067 3409 3750 4091 4775 5454 6135 6819 7500 8182 8863 9546 10226 2068 2481 2893 3310 3722 4135 4548 4961 5792 6616 7447 8275 9099 9928 10754 11583 12409 Double UIN 148397 148398 148399 148400 148401 148402 148403 148404 148405 148406 148407 148408 148409 148410 148411 148412 148413 148414 148415 148416 148417 148418 148419 148420 148421 148422 148423 148424 148425 148426 148427 148428 148429 148430 148431 148432 148433 148434 148435 148436 148437 148438 148439 148440 148441 148442 148443 148444 148445 148446 148447 Lo-Line Heat output Watts Btu/hr 673 808 942 1077 1211 1346 1481 1615 1884 2154 2423 2692 2961 3230 3500 3769 4038 827 992 1158 1323 1489 1654 1819 1985 2316 2646 2977 3308 3639 3970 4300 4631 4962 1046 1255 1464 1674 1883 2092 2301 2510 2929 3347 3766 4184 4602 5021 5439 5858 6276 2296 2757 3214 3675 4132 4593 5053 5512 6430 7351 8267 9187 10104 11023 11945 12863 13781 2822 3385 3951 4514 5082 5643 6206 6773 7902 9028 10158 11287 12416 13549 14672 15801 16934 3569 4282 4995 5712 6425 7138 7851 8564 9994 11420 12850 14276 15702 17132 18558 19987 21419 Designer - Concord Lo-Line Please note: All products over 2 metres wide will take 6 weeks to be delivered from date of order. When this product is ordered it cannot be cancelled. ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). 87 Stelrad Concord Range Lo-Line 40 Δt (65/55/20°C) Height 144 292 Designer - Concord 440 588 736 Length mm Elements 800 1000 1200 1400 1600 1800 2000 2200 800 1000 1200 1400 1600 1800 2000 2200 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 2 2 2 2 2 2 2 2 4 4 4 4 4 4 4 4 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 UIN 148308 148309 148310 148311 148312 148313 148314 148315 148316 148317 148318 148319 148320 148321 148322 148323 - Heat output Watts Btu/hr 396 496 -595 694 794 892 992 1091 672 839 1007 1175 1343 1511 1679 1846 - 1353 1692 2032 2368 2708 3045 3384 3724 2292 2864 3435 4009 4581 5155 5727 6299 - Single UIN 148346 148347 148348 148349 148350 148351 148352 148353 148354 148355 148356 148357 148358 148359 148360 148361 148362 148363 148364 148365 148366 148367 148368 148369 148370 148371 148372 148373 148374 148375 148376 148377 148378 148379 148380 148381 148382 148383 148384 148385 148386 148387 148388 148389 148390 148391 148392 148393 148394 148395 148396 Heat output Watts Btu/hr 286 343 400 457 515 571 628 686 800 914 1029 1143 1257 1372 1486 1600 1714 374 448 523 598 672 747 822 897 1046 1195 1345 1495 1644 1794 1943 2092 2242 453 544 634 726 816 907 997 1088 1269 1450 1632 1813 1994 2176 2357 2539 2720 975 1169 1365 1559 1756 1950 2144 2340 2731 3119 3510 3900 4290 4681 5069 5459 5850 1276 1529 1784 2039 2294 2550 2805 3060 3570 4078 4589 5099 5610 6120 6628 7138 7649 1547 1855 2164 2476 2784 3093 3402 3711 4331 4949 5569 6186 6804 7424 8042 8662 9280 Double UIN 148397 148398 148399 148400 148401 148402 148403 148404 148405 148406 148407 148408 148409 148410 148411 148412 148413 148414 148415 148416 148417 148418 148419 148420 148421 148422 148423 148424 148425 148426 148427 148428 148429 148430 148431 148432 148433 148434 148435 148436 148437 148438 148439 148440 148441 148442 148443 148444 148445 148446 148447 Single Heat output Watts Btu/hr 503 604 705 806 906 1007 1108 1208 1409 1611 1812 2014 2215 2416 2618 2819 3020 619 742 866 990 1114 1237 1361 1485 1732 1979 2227 2474 2722 2970 3216 3464 3712 782 939 1095 1252 1408 1565 1721 1877 2191 2504 2817 3130 3442 3756 4068 4382 4694 1718 2062 2404 2749 3091 3435 3780 4122 4808 5497 6184 6870 7557 8244 8933 9619 10306 2111 2532 2955 3377 3800 4221 4642 5066 5911 6753 7598 8443 9287 10132 10974 11819 12664 2670 3203 3736 4272 4806 5339 5873 6406 7475 8542 9611 10678 11745 12814 13881 14951 16017 Please note: All products over 2 metres wide will take 6 weeks to be delivered from date of order. When this product is ordered it cannot be cancelled. 88 Stelrad Concord Range 30 Δt (55/45/20°C) Height 144 292 440 588 736 Length mm Elements 800 1000 1200 1400 1600 1800 2000 2200 800 1000 1200 1400 1600 1800 2000 2200 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 2 2 2 2 2 2 2 2 4 4 4 4 4 4 4 4 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 UIN 148308 148309 148310 148311 148312 148313 148314 148315 148316 148317 148318 148319 148320 148321 148322 148323 - Heat output Watts Btu/hr 273 341 410 478 546 614 683 751 462 578 693 809 924 1040 1156 1271 - 931 1165 1399 1631 1864 2096 2330 2564 1578 1972 2365 2761 3154 3550 3943 4337 - Single UIN 148346 148347 148348 148349 148350 148351 148352 148353 148354 148355 148356 148357 148358 148359 148360 148361 148362 148363 148364 148365 148366 148367 148368 148369 148370 148371 148372 148373 148374 148375 148376 148377 148378 148379 148380 148381 148382 148383 148384 148385 148386 148387 148388 148389 148390 148391 148392 148393 148394 148395 148396 Heat output Watts Btu/hr 197 236 276 315 354 393 433 472 551 629 708 787 866 945 1023 1102 1180 258 308 360 411 463 514 566 617 720 823 926 1029 1132 1235 1337 1440 1543 312 374 437 500 562 624 686 749 874 999 1124 1248 1373 1498 1623 1748 1873 671 805 940 1074 1209 1342 1476 1611 1880 2147 2416 2685 2954 3223 3490 3759 4027 879 1053 1228 1404 1580 1755 1931 2107 2458 2808 3159 3511 3862 4214 4563 4915 5266 1065 1277 1490 1704 1917 2130 2342 2555 2982 3407 3834 4259 4685 5112 5537 5964 6389 Double UIN Heat output Watts Btu/hr 148397 148398 148399 148400 148401 148402 148403 148404 148405 148406 148407 148408 148409 148410 148411 148412 148413 148414 148415 148416 148417 148418 148419 148420 148421 148422 148423 148424 148425 148426 148427 148428 148429 148430 148431 148432 148433 148434 148435 148436 148437 148438 148439 148440 148441 148442 148443 148444 148445 148446 148447 347 1183 416 1420 485 1655 555 1892 624 2128 693 2365 763 2602 832 2838 970 3311 1109 3785 1248 4258 1386 4730 1525 5203 1663 5676 1803 6150 1941 6623 2080 7095 426 1453 511 1743 596 2035 681 2325 767 2616 852 2906 937 3196 1022 3488 1193 4070 1363 4649 1533 5231 1704 5813 1874 6394 2045 6976 2215 7556 2385 8138 2555 8719 539 1838 646 2205 754 2573 862 2942 970 3309 1077 3676 1185 4043 1293 4411 1508 5147 1724 5881 1939 6618 2155 7352 2370 8087 2586 8823 2801 9557 3017 10294 3232 11028 Double Designer - Concord Lo-Line Please note: All products over 2 metres wide will take 6 weeks to be delivered from date of order. When this product is ordered it cannot be cancelled. 89 Stelrad Concord Range Vertical Vertical Height Length mm Elements 1800 2000 440 588 736 440 588 736 6 8 10 6 8 10 50 Δt (75/65/20°C) Heat output Watts Btu/hr UIN 148340 148341 148342 148343 148344 148345 780 1040 1300 870 1160 1450 2661 3548 4436 2968 3958 4947 ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). 40 Δt (65/55/20°C) 30 Δt (55/45/20°C) Designer - Concord Vertical Height Length mm Elements 1800 2000 440 588 736 440 588 736 6 8 10 6 8 10 UIN 148340 148341 148342 148343 148344 148345 Heat output Watts Btu/hr 583 778 972 651 868 1085 UIN 148340 148341 148342 148343 148344 148345 1991 2654 3318 2220 2961 3701 Concord Plane & Lo-Line EN 442 Certification Data - CETIAT tested in accordance with BS EN 442 Type Height W/m at 75/65/20 n-coefficients Heated Surface Area (m²/m) Weight (kg/m) Water contents (l/m) Wall to tap centre (mm) Lo-Line 144 663 1.23 2.47 12.57 1.77 44 Single 292 1122 1.28 5.12 25.05 3.57 94 440 764 1.27 4.9 18.23 2.68 44 588 999 1.29 6.58 25.01 3.54 44 Double 736 1212 1.29 6.92 31.98 4.43 44 440 1346 1.31 7.71 32.79 5.31 94 588 1654 1.34 10.37 45.01 7.09 94 736 2092 1.34 11.06 57.44 8.86 94 Concord Vertical EN 442 Certification Data - CETIAT tested in accordance with BS EN 442 Type Height W/m at 75/65/20 n-coefficients Heated Surface Area (m²/m) Weight (kg/m) Water Contents (l/m) Wall to tap centre (mm) Vertical 1800 1770 1.31 3.95 45.14 9.68 44 2000 1972 1.31 4.36 49.77 10.64 44 Slimline 1800 2725 1.30 6.9 77.81 17.5 50 2000 3056 1.31 7.65 78.5 19.25 50 U 90 Heat output Watts Btu/hr 402 536 670 448 597 747 1371 1827 2284 1529 2038 2548 Stelrad Concord Range Slimline Slimline Height Length mm Elements 320 440 520 640 320 440 520 640 8 11 13 16 8 11 13 16 1800 2000 50 Δt (75/65/20°C) Heat output Watts Btu/hr UIN 148300 148301 148302 148303 148304 148305 148306 148307 872 1199 1417 1744 978 1344 1589 1956 2975 4091 4835 5951 3337 4586 5422 6674 ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). 40 Δt (65/55/20°C) 30 Δt (55/45/20°C) Height Length mm Elements 320 440 520 640 320 440 520 640 8 11 13 16 8 11 13 16 1800 2000 UIN 148300 148301 148302 148303 148304 148305 148306 148307 Heat output Watts Btu/hr 652 897 1060 1305 732 1005 1189 1463 2225 3060 3616 4451 2496 3430 4055 4992 UIN 148300 148301 148302 148303 148304 148305 148306 148307 Heat output Watts Btu/hr 449 617 730 898 504 692 818 1007 1532 2107 2490 3065 1719 2362 2792 3437 Designer - Concord Slimline Concord Slimline EN 442 Certification Data - CETIAT tested in accordance with BS EN 442 Type Height W/m at 75/65/20 n-coefficients Heated Surface Area (m²/m) Weight (kg/m) Water Contents (l/m) Wall to tap centre (mm) Vertical 1800 1770 1.31 3.95 45.14 9.68 44 2000 1972 1.31 4.36 49.77 10.64 44 Slimline 1800 2725 1.30 6.9 77.81 17.5 50 2000 3056 1.31 7.65 78.5 19.25 50 91 Concord Plane Single fixing positions All dimensions in mm. Inches in brackets. 2 (0.08) 15 (0.59) 45 (1.77) 40 (1.57) 150 (5.90) 60 (2.36) M 8 128 (5.04) 60 (2.36) 65 (2.56) M 8 L = 1600-3000 150 (5.90) 150 (5.90) 40 (1.57) H = 212-709 60 (2.36) L = 500-1400 Designer - Concord 70 (2.76) 150 (5.90) 150 (5.90) Concord Plane Double fixing positions All dimensions in mm. Inches in brackets. 110 (4.33) M8 55 (2.17) L = 500-1400 18 (0.71) 20 (0.79) 150 (5.90) 150 (5.90) 92 150 (5.90) 40 (1.57) H = 212-2129 60 (2.36) L = 1600-3000 150 (5.90) 150 (5.90) Concord Lo-Line fixing positions All dimensions in mm. Inches in brackets. 18 (0.71) 20 (0.79) 110 (4.33) M8 128 (5.90) 55 (2.17) L = 800-1400 L = 1600-2200 150 (5.90) 150 (5.90) 60 (2.36) 40 (1.57) H = 212-2129 H = 141 60 (2.36) L = 800-2200 150 (5.90) 150 (5.90) Designer - Concord 150 (5.90) 40 (1.57) *Welded-on foot supports recommended 150 (5.90) Concord Lo-Line 144mm has unique brackets. Concord Vertical fixing positions All dimensions in mm. Inches in brackets. 107 (4.21) H = 1800-2000 20 (0.79) 115 (4.53) 107 (4.21) 115 (4.53) 107 (4.21) 115 (4.53) 18 (0.71) 55 (2.17) Hardware pack includes air vents, saddle clips & branding clips. Concord Slimline fixing positions 44 (1.73) All dimensions in mm. Inches in brackets. 93 Concord Plane Single, Concord Plane Double, Concord Lo-Line and Concord Vertical wall mounting information 15 (0.59) 50 (1.97) 10 (0.39) 27 (1.06) Type Plane Single Plane Double Vertical From back of radiator to wall D mm 9 27 25 in 0.35 1.06 0.98 From wall to centre of connections D1 mm 44 94 44 in 1.73 3.70 1.73 From front of radiator to wall D2 mm 69 119 70 in 2.72 4.69 2.76 30 (1.18) 45 (1.77) 10 (0.39) D2 Lo-Line 10 (0.39) D 15 (0.59) Concord Slimline wall mounting information All dimensions in mm. Inches in brackets. D2 35 (1.38) 40 (1.57) Designer - Concord 50 (1.97) DI 80 DI (3.15) Slimline Back face Connection centres Front face to finished wall from finished wall from finished wall D D1 D2 mm 35 in 1.38 mm in 50 1.97 mm 130 in 5.12 Concord piping options 94 D 70min (2.76) Type 27 (1.06) 45 (1.77) 45 (1.77) All dimensions in mm. Inches in brackets. Concord Plane and Lo-Line floor mounting positions All dimensions in mm. Inches in brackets. Must be specified at time of ordering as they are securely welded during manufacture. Floor mounting brackets illustration. 100 (3.94) This is a made to order product and once ordered it cannot be cancelled. 150 (5.91) Designer - Concord 70 (2.76) 120 (4.72) 150 (5.91) 95 Stelrad Classic Column Range Horizontal 50 Δt (75/65/20°C) Height 300 Designer - Classic Column 500 600 750 Length mm Columns 444 628 858 1042 1272 1456 1870 444 628 858 1042 1272 628 858 1042 1272 444 628 858 1042 1272 1456 1870 444 628 858 1042 1272 628 858 1042 1272 444 628 858 1042 1272 1456 1870 444 628 858 1042 1272 858 1042 1272 1456 1870 444 628 858 1042 1272 3 3 3 3 3 3 3 4 4 4 4 4 2 2 2 2 3 3 3 3 3 3 3 4 4 4 4 4 2 2 2 2 3 3 3 3 3 3 3 4 4 4 4 4 3 3 3 3 3 4 4 4 4 4 UIN Heat output Watts Btu/hr 163000 163001 163002 163003 163004 163005 163006 163007 163008 163009 163010 163011 163012 163013 163014 163015 163016 163017 163018 163019 163020 163021 163022 163023 163024 163025 163026 163027 163028 163029 163030 163031 163032 163033 163034 163035 163036 163037 163038 163039 163040 163041 163042 163043 163044 163045 163046 163047 163048 163049 163050 163051 163052 163053 288 983 416 1419 576 1965 704 2402 864 2948 992 3385 1280 4367 377 1286 545 1860 754 2573 922 3146 1131 3861 499 1703 691 2358 845 2883 1037 3538 464 1585 671 2289 929 3170 1135 3873 1393 4755 1600 5459 2064 7044 608 2074 879 2999 1217 4152 1487 5074 1825 6227 589 2010 815 2781 997 3402 1223 4173 548 1870 792 2702 1096 3740 1340 4572 1644 5612 1888 6442 2436 8312 718 2450 1037 3538 1436 4900 1756 5991 2155 7353 1337 4562 1635 5579 2006 6844 2303 7861 2972 10140 877 2992 1266 4320 1753 5981 2143 7312 2630 8974 ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). 96 Stelrad Classic Column Range Horizontal 40 Δt (65/55/20°C) 30 Δt (55/45/20°C) 300 500 600 750 Length mm Columns 444 628 858 1042 1272 1456 1870 444 628 858 1042 1272 628 858 1042 1272 444 628 858 1042 1272 1456 1870 444 628 858 1042 1272 628 858 1042 1272 444 628 858 1042 1272 1456 1870 444 628 858 1042 1272 858 1042 1272 1456 1870 444 628 858 1042 1272 3 3 3 3 3 3 3 4 4 4 4 4 2 2 2 2 3 3 3 3 3 3 3 4 4 4 4 4 2 2 2 2 3 3 3 3 3 3 3 4 4 4 4 4 3 3 3 3 3 4 4 4 4 4 UIN 163000 163001 163002 163003 163004 163005 163006 163007 163008 163009 163010 163011 163012 163013 163014 163015 163016 163017 163018 163019 163020 163021 163022 163023 163024 163025 163026 163027 163028 163029 163030 163031 163032 163033 163034 163035 163036 163037 163038 163039 163040 163041 163042 163043 163044 163045 163046 163047 163048 163049 163050 163051 163052 163053 Heat output Watts Btu/hr 215 311 431 527 646 742 957 282 408 564 690 846 373 517 632 776 347 502 695 849 1042 1197 1544 455 657 910 1112 1365 441 610 746 915 410 592 820 1002 1230 1412 1822 537 776 1074 1313 1612 1000 1223 1500 1723 2223 656 947 1311 1603 1967 735 1062 1470 1797 2205 2532 3267 962 1391 1924 2353 2887 1274 1764 2157 2647 1184 1713 2371 2897 3555 4083 5268 1552 2243 3106 3795 4658 1503 2080 2545 3121 1399 2021 2797 3420 4196 4819 6217 1832 2647 3665 4482 5500 3412 4173 5120 5878 7585 2238 3231 4474 5469 6712 UIN 163000 163001 163002 163003 163004 163005 163006 163007 163008 163009 163010 163011 163012 163013 163014 163015 163016 163017 163018 163019 163020 163021 163022 163023 163024 163025 163026 163027 163028 163029 163030 163031 163032 163033 163034 163035 163036 163037 163038 163039 163040 163041 163042 163043 163044 163045 163046 163047 163048 163049 163050 163051 163052 163053 1 Heat output Watts Btu/hr 148 214 297 363 445 511 659 194 281 388 475 582 257 356 435 534 239 346 478 585 717 824 1063 313 453 627 766 940 303 420 513 630 282 408 564 690 847 972 1255 370 534 740 904 1110 689 842 1033 1186 1531 452 652 903 1104 1354 506 731 1012 1237 1518 1743 2249 662 958 1325 1620 1987 877 1214 1485 1822 815 1179 1632 1994 2448 2811 3627 1068 1545 2138 2613 3207 1035 1432 1752 2149 963 1392 1926 2355 2889 3318 4280 1262 1822 2523 3086 3787 2349 2873 3525 4047 5222 1541 2225 3080 3766 4621 Designer - Classic Column Height 97 Stelrad Classic Column Range Vertical 50 Δt Height (75/65/20°C) Length mm Columns 352 444 352 444 352 444 2 2 2 2 2 2 1800 2000 2500 UIN 163054 163055 163056 163057 163058 163059 Heat output Watts Btu/hr 868 1116 966 1242 1197 1539 2962 3808 3296 4238 4084 5251 ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). 40 Δt (65/55/20°C) 30 Δt (55/45/20°C) Height Length mm Columns 352 444 352 444 352 444 2 2 2 2 2 2 Designer - Classic Column 1800 2000 2500 UIN 163054 163055 163056 163057 163058 163059 Heat output Watts Btu/hr 649 835 723 929 895 1151 UIN Heat output Watts Btu/hr 447 575 497 640 616 793 2215 2848 2465 3170 3055 3928 1525 1961 1697 2182 2103 2704 EN 442 Certification Data - CETIAT tested in accordance with BS EN 442 Type Height W/m at 75/65/20 n-coefficients Heated Surface Area (m²/m) Weight (kg/m) Water Contents (l/m) Wall to tap centre (mm) 98 2 Columns 500 835 1.25 1.52 17.39 10.87 54 / 59 600 985 1.25 1.96 21.74 13.04 54 / 59 1800 2696 1.31 6.09 58.7 32.61 54 / 59 2000 3000 1.31 6.74 65.22 36.96 54 / 59 3 Columns 2500 3717 1.3 8.48 80.43 44.72 54 / 59 300 696 1.25 1.52 15.22 13.04 73 / 78 500 1122 1.25 2.39 26.09 17.39 73 / 78 600 1324 1.26 3.04 30.43 19.57 73 / 78 4 Columns 750 1615 1.26 3.7 36.96 23.91 73 / 78 300 911 1.25 1.96 21.74 15.22 91 / 96 500 1469 1.26 3.26 36.96 21.74 91 / 96 600 1734 1.27 4.13 43.48 26.09 91 / 96 750 2117 1.27 5 54.35 30.43 91 / 96 Classic Column typical valve installation All dimensions in mm. Inches in brackets. The air vent 12.7 (0.50) BSP 1/2” Blank plugs Angle valve (not included) Angle valve (not included) BSP 1/2” 12.7 (0.50) BSP 1/2” 12.7 (0.50) Note: Factory fitted bushes are welded in place and not removable. If installing TBOE (Top Bottom Opposite End) please note that the radiator MUST be inverted. Designer - Classic Column S Classic Column typical bracket installation All dimensions in mm. Measurements using 10mm CVD Brackets Slot Add 5mm if using 15mm Slot D2 WA Clamp 2 Col 3 Col 4 Col WA 23 23 23 D 54 73 91 D2 85 123 159 Brackets and Clamps Required 4 6 No of Sections 0 - 23 24 - 41 Bracket D Pressure drops 150mm recommended minimum Classic Column optional floor mounting brackets All dimensions in mm. Inches in brackets. 55mm 100 - 150mm Floor stands 130 (5.12)-190 (7.48) 85mm 99 Stelrad Swing 50∆t (75/65/20°C) P+ K2 Height Emitter length mm Casing length mm UIN 1820 2020 400 500 600 504 604 704 38418210 38518210 38618210 1224 1530 1836 400 500 600 504 604 704 38420210 38520210 38620210 1308 1635 1962 Heat output Watts Btu/hr Casing length mm UIN Heat output Watts Btu/hr 4176 5220 6264 527 627 727 38418220 38518220 38618220 1476 1845 2214 5036 6295 7554 4463 5579 6694 527 627 727 38420220 38520220 38620220 1584 1980 2376 5405 6756 8107 ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). Designer - Swing 40∆t (65/55/20°C) P+ K2 Height Emitter length mm Casing length mm UIN 1820 2020 400 500 600 504 604 704 38418210 38518210 38618210 863 1078 1294 400 500 600 504 604 704 38420210 38520210 38620210 922 1152 1383 30∆t (55/45/20°C) Heat output Watts Btu/hr UIN 2943 3679 4415 527 627 727 38418220 38518220 38618220 1040 1300 1560 3549 4437 5324 3146 3932 4718 527 627 727 38420220 38520220 38620220 1116 1396 1675 3809 4762 5714 P+ K2 Height Emitter length mm Casing length mm UIN 1820 2020 400 500 600 504 604 704 38418210 38518210 38618210 630 788 945 400 500 600 504 604 704 38420210 38520210 38620210 674 842 1010 Heat output Watts Btu/hr Casing length mm UIN 2151 2688 3226 527 627 727 38418220 38518220 38618220 760 950 1140 2594 3242 3890 2298 2873 3447 527 627 727 38420220 38520220 38620220 816 1020 1224 2784 3479 4175 EN 442 Certification Data - CETIAT tested in accordance with BS EN 442 Type 100 P+ Heat output Watts Btu/hr Casing length mm K2 Height W/m at 75/65/20 n-coefficients Heated Surface Area (m²/m) 1820 3060 1.30 13.58 2020 3270 1.30 16.20 1820 3690 1.33 29.90 2020 3960 1.33 37.74 Weight (kg/m) Water Contents (l/m) Wall to tap centre (mm) 96.00 15.90 65 106.20 17.70 65 105.30 15.90 77 116.40 17.70 77 Heat output Watts Btu/hr Stelrad Swing mounting brackets H4 Height mm H2 in H3 H4 mm in mm in 1800 70.87 70 2.75 830 43.89 1590 63.58 mm in 2000 78.74 70 2.75 930 47.83 1790 71.46 H3 H2 Stelrad Swing wall mounting information All dimensions in mm. Inches in brackets. K2 106 96 129 119 Display: Front of radiator Designer - Swing P+ Swing piping options Tapping Centres P+ K2 65 50 LH L 77 28 (1.10) 28 (1.10) 50 (1.97) L - P+ mm L - K2 mm LH mm 504 527 344 604 627 444 704 727 544 LENGTH - 56(2.20) LENGTH Comes complete with Stelrad’s class leading safety bracket. 101 Stelrad Caliente Vertical S 50 Δt Single Tube (75/65/20°C) Height 1200 1800 Length mm Elements 330 495 330 429 495 528 660 726 10 15 10 13 15 16 20 22 Double Tube Heat output Watts Btu/hr UIN 401211330 485 401211495 727 401811330 702 401811429 912 401811528 1123 401811660 1404 401811726 1544 1655 2481 2395 3112 3832 4790 5268 UIN 401822495401822660 - Heat output Watts Btu/hr 1590 2120 - 5425 7233 - ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). 40 Δt 30 Double Δt Single Btu/hr Watts Btu/hr Tube (55/45/20°C) Tube Single Tube (65/55/20°C) Double Watts Btu/hr Tube 4 Designer - Caliente Height 1200 1800 Length mm Elements 330 495 330 429 495 528 660 726 10 15 10 13 15 16 20 22 UIN 401211330 401211495 401811330 401811429 401811528 401811660 401811726 Heat output Watts Btu/hr 281 421 406 528 650 812 893 1238 1855 1792 2328 2866 3583 3941 UIN Heat output Watts Btu/hr 401822495 920 401822660 1226 - 4058 5411 - EN 442 Certification Data - CETIAT tested in accordance with BS EN 442 Type Height W/m at 75/65/20 n-coefficients Heated surface area (m2/m) Weight (kg/m) Water contents (l/m) Tapping Centres from wall 102 Single Double 1200 1470 1.27 2.28 23.33 10.61 1800 2126 1.28 3.43 33.64 15.15 1800 3212 10.28 6.85 64.85 28.18 38 38 70 UIN 401211330 401211495 401811330 401811429 401811528 401811660 401811726 Heat output Watts Btu/hr 250 374 362 470 578 723 795 852 1277 1234 1603 1973 2467 2713 UIN Heat output Watts Btu/hr 401822495 819 401822660 1092 - 2794 3725 - Stelrad Caliente Horizontal S 50 Δt Single Tube (75/65/20°C) Height Length mm Elements 594 800 1000 1200 1400 18 18 18 18 Heat output Watts Btu/hr UIN 405911800 626 405911100 782 405911120 938 405911140 1095 2136 2668 3200 3736 Double Tube UIN Heat output Watts Btu/hr 4 405922800 969 405922100 1211 - 3306 4132 - ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). Single Tube (65/55/20°C) Height Length mm Elements 594 800 1000 1200 1400 18 18 18 18 UIN 405911800 4 405911100 405911120 405911140 Heat output Watts Btu/hr 468 584 701 819 1598 1996 2394 2795 Double Tube UIN 405922800 405922100 - 30 Δt (55/45/20°C) Heat output Watts Btu/hr 724 905 - 2473 3091 - UIN 405911800 405911100 405911120 405911140 Single Tube Heat output Watts Btu/hr Btu/hr 322 403 483 564 1100 1374 1648 1924 Double Tube UIN 405922800 405922100 - Heat output Watts Btu/hr Btu/hr 499 624 - 1703 2128 - Designer - Caliente 40 Δt EN 442 Certification Data - CETIAT tested in accordance with BS EN 442 Type Height W/m at 75/65/20 n-coefficients Heated surface area (m2/m) Weight (kg/m) Water contents (l/m) Tapping Centres from wall Single Double 594 782 1.25 1.13 12.2 5.49 38 594 1210 1.26 2.26 22.6 12.47 70 103 Caliente wall mounting information All dimensions in mm. Inches in brackets. 66 (2.59) 66 (2.59) 108 (4.17) 38 (1.49) 74 (2.91) 66 (2.59) 70 (2.75) 66 (2.59) w 159 (6.25) 159 (6.25) H H 141 (5.55) 141 (5.55) w F/R R/F 24.5 (0.96) Air vents R/F 150 (5.90) 150 (5.90) 150 (5.90) 19 (0.75) W=30 (1.49) 19 (0.75) 70 (2.75) 62 (2.44) 62 (2.44) 38 (1.49) 74 (2.91) 150 (5.90) W-49 (1.92) 19 (0.75) W=30 (1.49) 2 The Stelrad STARS Heatloss Calculator contains an inbuilt U value calculator. Save time and effort by using the Stelrad STARS program the perfect solution for accurate sizing and design flexibility. Visit www.starsapp.co.uk 104 19 (0.75) 70 (2.75) F/R 24.5 (0.96) 70 (2.75) 24.5 (0.96) W-49 (1.92) 106 (4.17) Designer - Caliente 24.5 (0.96) Product Specification Tube diameter = Ø20mm and Ø38mm Steel thickness = 1.25mm for Ø20 ; 1.4mm for Ø38 Working pressure = 4 bar Operating temp = 110° max Stelrad Excel 50 Δt (75/65/20°C) Floor Mounted Height Length mm Max Projection mm UIN 1800 2000 380 500 500 60 60 60 147145 147180 147215 Heat output Watts Btu/hr 727 957 1048 2481 3266 3577 Wall Mounted Max Projection mm UIN 60 60 60 147040 147075 147110 Heat output Watts Btu/hr 727 957 1048 2481 3266 3577 ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). 2000 1800 380 500 W Btu/hr Designer - Excel U 500 Brackets positions Btu/hr W Btu/hr 105 Stelrad Arc & Wave 50 Δt (75/65/20°C) 50 Δt (75/65/20°C) Arc Height Length mm Max Projection mm UIN 1800 380 440 620 200 200 200 147037 147038 147039 Wave Heat output Watts Btu/hr Height Length mm Max Projection mm UIN 882 1021 1438 1800 380 440 620 200 200 200 147034 147035 147036 3010 3484 4908 Heat output Watts Btu/hr 882 1021 1438 ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). Designer - Arc & Wave Arc 1800 Wave H W 380 Btu/hr W 1800 Btu/hr 620 440 380 Brackets positions for both Arc and Wave W 106 Btu/hr W Btu/hr 440 620 3010 3484 4908 Stelrad Vistaline 50 Δt 2 3 (75/65/20°C) Height Length mm Max Projection mm UIN 1800 320 440 620 500 620 740 60 60 60 60 60 60 147250 147285 147320 147355 147390 147425 2000 Heat output Watts Btu/hr 742 1021 1438 1275 1580 1886 2532 3484 4908 4351 5392 6437 Max Projection mm UIN 66 66 66 66 66 66 147460 147495 147530 147565 147600 - Heat output Watts Btu/hr 818 1130 1597 1415 1758 - 2792 3856 5450 4829 6000 - Designer - Vistaline ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). H Vistaline 2 Single row Vistaline 3 Double offset row 20 L - 40 20 L Brackets positions Tapping centre for the Vistaline 42 48 60 66 H o12 H-22 L - 40mm Perpendicular to the manifold 4 11 H - 22mm (+ _ 2mm) In line with the manifold *Coupling protudes 10mm 19 38 20 L-40 L S Standard fitting EG o/ 1⁄2" EG 107 Stelrad Ellipse 50 Δt EH EOH (75/65/20°C) Height Length mm Max Projection mm UIN 1800 2000 459 689 459 689 765 65 65 65 65 65 147635 147670 147705 147740 147775 Heat output Watts Btu/hr 858 1287 954 1431 1590 2928 4392 3256 4884 5426 Max Projection mm UIN 65 65 65 65 65 147810 147845 147880 147915 147950 Heat output Watts Btu/hr 858 1287 954 1431 1590 2928 4392 3256 4884 5426 ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). H W H W Btu/hr Btu/hr Designer - Ellipse H Ellipse EH Inward Ellipse EOH Alternate 20 L - 40 20 L Brackets positions Tapping centres EH model L - 40mm Perpendicular to the manifold 46 65 H 14 H-22 2.5 11 H - 22mm (+ _ 2mm) In line with the manifold *Coupling protrudes 10mm 19 38 S Standard fitting EG o/ 1⁄2" 108 EG 20 L-40 L Stelrad Optia 50 Δt (75/65/20°C) Height Length mm Max Projection mm UIN 1800 160 200 240 202 242 282 147985 147986 147987 Heat output Watts Btu/hr 742 928 1114 2532 3167 3802 ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). 1800 Btu/hr Watts Btu/hr Designer - Optia U 160 200 Side view Brackets assembly 240 220 Front view Brackets positions 109 Energy Saving Improves energy efficiency and comfort whilst reducing bills. A radiator that produces more comfort at less cost The power we use in buildings accounts for 40% of global consumption. And that has a massive impact on the environment. But with smarter energy management, our buildings can emit up to 60% less CO2. That’s something the European Union are moving towards, by making energy consumption standards stricter. • The Stelrad Radical energy saving radiator reaches its maximum temperature 23% faster than a traditional radiator • It reaches its optimum performance level while a traditional heater is still heating up • After only 2 minutes it offers up to 50% more radiant heat • With higher radiant heat, the feeling of 20°C can be achieved at a lower temperature setting At Stelrad, we believe the heating industry has a major role to play, by developing systems that work so efficiently that they produce more heat at lower temperatures. That’s why we’ve developed Stelrad Radical, the energy saving radiator. It produces more radiant heat than traditional radiators - saving energy while raising comfort levels. At less cost to the user, and to the environment. That’s a Radical step forward. The Stelrad Radical energy saving radiator’s unique and innovative technology raises comfort levels. And by working more efficiently, it reduces energy bills - with a saving of up to 10.5%. Raising comfort levels with more radiant heat A radiator that delivers more heat, more efficiently. A radiator that reduces energy bills by up to 10.5% Energy Saving - Radical Your choice of radiator determines how comfortable the heating in your home feels. And how much that comfort costs. You know how a draught free room at 20°C can still feel uncomfortable? The energy saving radiant heat of the Stelrad Radical will soon fix that. And with the outstanding energy efficiency delivered by its preset valve, it reduces your bills by up to 10.5%, too. • Thanks to the controlled flow of our unique Domestic heating is usually based on convection and radiation. With convection heating, hot air rises from the heating elements, cools down, descends via the wall and is heated again. With radiant heating, infrared radiation is sent directly around the room regardless of airflows like wind or drafts. Radiant heat heats up the room, furniture and people, and is reflected back to create a more comfortable feeling similar to the rays of the sun. And standing in the sun always feels much warmer, even if the surrounding temperature is no higher than in the shadow because it is radiant heat. direct intake technology, the water in the front panel reaches a temperature up to 50% higher than in a traditional radiator For further information and advice call 0844 543 6200 110 • In a traditional radiator the heat generated consists, on average, of 80% convection heat and 20% radiant heat - limiting the feeling of warmth • The Stelrad Radical energy saving radiator increases radiant heat by up to 50% Supported by a RIBA & CIBSE CPD programme CPD Stelrad are certified as a member of the RIBA and CIBSE CPD Providers Network. This means we can provide RIBA and CIBSE approved CPD material to architects and other specifiers. An hour-long programme delivered by a member of the Stelrad team delivers information on every aspect of the Stelrad Radical energy saving radiator and its application. Energy savings tested, assessed and declared by KIWA KIWA is a highly respected Pan European institute So the comfortable feeling of a room at 20ºC is providing internationally recognized declaration services achieved at a setting of 1 degree less (or even lower). for systems and products. As an independent expert KIWA also carries out specialist testing, and the KIWA Up to 50% more radiant heat means more comfort - at a lower cost Gas Technology division has rigorously trialled the Stelrad Radical radiator to assess and declared its energy saving performance. These thermal images demonstrate the improved radiant heat of the Stelrad Radical radiator. The measurements show that the Stelrad Radical energy saving radiator offers 1.5 times more radiant capacity Compatibility The Stelrad Radical radiator is compatible with the following: at 50% of the nominal flow (which offers 90% of the So depending on the radiator size and type it is compared • Gas boilers • Electric boilers to, the Stelrad Radical energy saving radiator offers • Solar PV up to 50% more radiant heat. • Ground source heat pumps (GSHP) Energy Saving - Radical nominal heat output) compared to a traditional radiator. • Air source heat pumps (ASHP) • Biomass installations At 8 minutes, with 50% of nominal flow At 8 minutes with nominal flow Test conditions: radiator K2, height 600mm, length 1000mm, temperatures 70/55/20°C. 111 A radiator that heats the room, not the wall Heating up fully in less time Traditional radiators are as warm at the back as they dramatically shorter for the Stelrad Radical compared are at the front. So valuable energy is wasted, as the to a traditional radiator. heat goes into and through the wall. 1. Directed flow The unique and innovative technology of the Stelrad Hot water is directed into and around the front panel. Radical radiator changes all that. The flow connection In a traditional radiator the water flow divides in parallel to the front panel and the return connection into the to front and back panel. back ensures that you feel warmer, faster. And thanks to the higher radiation from the front panel, the back panel is much cooler than with other radiators. So up to 9% less radiant heat is lost through the back of the radiator. Thanks to its unique flow pattern, heat up times are 2. Distribution of hot water Hot water rises in one water channel and is distributed equally over the front panel. A unique system then directs it to the back panel where it is spread equally over the back panel water channels. That’s not just good for comfort levels. It also means 3. Faster heat up the heating system is more efficient, which reduces The front panel of the Stelrad Radical radiator reaches bills - and CO2 emissions. a temperature of 62.5°C after 8.5 minutes. At that time, the front panel of a traditional radiator is at 59.3°C. It only Less heat lost into the wall reaches its maximum temperature after 11 minutes, by which time the Stelrad Radical has already been operating at maximum for 2.5 minutes. Fast, convenient and flexible fitting Radical radiator Standard radiator Energy Saving - Radical Fully compatible with renewable energy resources The Stelrad Radical energy saving radiator is perfectly suited for both solo and multiple heating installations. It can be connected to a modulating gas Angle H Block Straight H Block with couplings or fuel burner and is compatible with all kinds of low temperature systems, such as heat pumps, solar cells and biomass installations. Faster heating means less CO2 and lower energy bills Higher radiant heat levels and front panel temperatures combine with other benefits to reduce bills and CO2 emissions. 112 Simple and quick to connect with Hydro Block (H Block) Simple and quick to connect with Hydro Block (H Block) With the 3⁄4" male thread, the H Block’s central connection means you can connect pipes directly to the Stelrad Radical radiator with additional couplers. This reduces the risk of leaks and improves the installation speed. Central connection The connection coupling of the Stelrad Radical is located in the middle of the radiator. This means that the location of the connection no longer depends on the length of the radiator, so pipes can be laid down early in the project with no need to know the size of the radiator. The H Block connects the radiator to the flow and return pipe and has a built-in drain off function, valve isolator and a lock shield for ease of installation and servicing. • Two H Block configurations are available: with straight connections for pipes coming from the floor or angle connections for pipes coming from the wall. • The H Block pack also includes a choice of coupling pieces to connect the H Block to the pipes - either 10mm or 15mm. Installers should order a completed unit based on the appropriate H Block variation. Left or right side valve position The Stelrad Radical radiator’s valve can be mounted on Thermostatic head with build-in sensor either the left or right side without having to adjust the Technical data supply and return pipes. (K2 only). • Setting range 6°C to 28°C (43°F to 82°F) • Valve stroke limiter • Setting numbers 1 to 5 • ❄Frost protection 6°C (43°F) Energy Saving - Radical • Max. sensor temperature 50°C (122°F) • Hysteresis 0.3 K • Water temperature influence 0.7 K • Differential pressure influence 0.3 K Preset thermostatic valve • Closing time 24 minutes The thermostatic valve regulates the water supply in the radiator. This valve is preset in the factory according to the radiator’s size, which guarantees optimum efficiency. Thermostatic label 113 Impacting heating levels - and costs Example 1 shows the effect of an unbalanced system. Example 2 shows how more efficient a balanced system is. Example 1: An unbalanced system Installation with 8 radiators Pump with 800 l/h capacity Required temperature regime: 70/55 °C Water flow not adjusted à around 100 l/h per radiator (assuming same pressure losses for all radiators). Condensing boiler Thermostatic head 70°C 65 °C Lockshield valve 70 °C 65 °C 70 °C 60 °C 70 °C 55 °C 70 °C 45°C Water flow through small radiators is (much) larger than required and leads to a higher return temperature. Water flow through large radiators is (much) lower than required and leads to lower return temperature. Room does not always get heated up properly. Too high water flow can generate noise in the installation. In case of a condensing boiler, the return temperature will often be too high to allow condensing , leading to lower boiler efficiency. To avoid these problems, it is necessary to balance the heating system by adjusting the water flow rate to each radiator. The right flow rate leads to a correct return temperature out of each radiator and, therefore, the correct heat output for each radiator, as illustrated in example 2. Example 2: Energy Saving - Radical A balanced system Installation with 8 radiators Pump with 800 l/h capacity Required temperature regime: 70/55 °C Water flow adjusted with integrated valve inserts Condensing boiler à optimal water flow for each radiator. Thermostatic head mounted on integrated valve insert 70 °C 55 °C 70 °C 55 °C 70 °C 55 °C 70 °C 55 °C 70 °C Water flow is optimised to each radiator ie. low to small radiators, large to big radiators. The required return temperature is achieved, the radiators work in optimal conditions. The pump can eventually work at lower position, thus reducing pump consumption costs. The return temperature is low enough to allow condensing, leading to optimal boiler efficiency. This is why the Stelrad Radical radiator is delivered with a thermostatic valve that is factory-adjusted according to the radiator size. By doing so, Stelrad help reduce energy costs. 114 55 °C Preset valves - environmentally friendly and energy efficient Height Every Stelrad Radical radiator is equipped with Type a preset valve, which enhances the efficiency of 400 the system and reduces energy consumption. 500 300 K2 K1 K2 5.5 5.5 5.5 5.5 5.5 5.5 5.5 2.5 600 5.5 2.5 5.5 2.5 700 5.5 2.5 5.5 2.5 temperature - and is an essential element in the 800 5.5 2.5 2.5 2.5 Stelrad Radical energy saving design. 900 2.5 2.5 2.5 2.5 2.5 2.5 flow, producing maximum efficiency at optimum 1000 You can recognise the setting by the coloured valve closure (yellow, white, red, black or blue). The default setting is matched to the heat output of the radiator K2 5.5 5.5 600 K1 This valve is preset in order to control the water K1 500 5.5 2.5 2.5 4.5 2.5 4.5 4.5 2.5 4.5 2.5 4.5 2.5 6 2.5 6 4.5 8 2.5 6 4.5 8 4.5 8 4.5 8 1100 2.5 1200 2.5 at system temperatures of both 70/55/20°C 1400 and 55/45/20°C. 1600 2.5 2.5 1800 2000 2.5 4.5 The benefits • No extra adjustment time during installation • Optimal water flow in the radiator • Higher efficiency of the condensing boiler through lower return temperatures • Environmentally friendly • Lower energy costs 5.5 2.5 4.5 6 8 4361 4360 4360 4360 4360 Energy Saving - Radical • Compliance with Rule EnEV for hydraulic balance Factory presetting conditions: - heat outputs at 70/55/20ºC (∆t = 15°C ) - pressure drop ∆p = 100mbar For other system conditions, the valve can be readjusted (or replaced) according to preset tables 4360 and 4361 (using preset key - part of the hardware pack). In one pipe systems the valve must be fully opened (position 8). 115 Valve re-adjustment Fine tuning valve 4361 Max. 2 K presetting 6800 D t [K] Dp [mbar] 50 100 150 10 8 7 8 8 6 7 7 8 8 8 50 1 3 3 5 6 7 7 8 8 8 15 100 150 1 1 1 1 3 5 1 1 1 3 5 6 6 4 5 6 7 8 6 6 8 8 7 8 8 50 1 1 1 3 5 6 6 7 7 8 8 20 100 150 1 1 1 1 3 1 1 1 1 4 5 5 3 3 4 6 6 5 6 7 8 8 8 6 7 7 8 8 8 1 1 1 1 1 1 1 1 3 3 1 1 1 1 1 1 4 5 3 3 1 1 6 6 7 7 8 4 5 5 6 6 3 3 4 5 6 8 6 6 40 50 100 150 8 8 7 7 8 8 6 6 7 7 8 8 8 8 7 8 8 8 8 Energy Saving - Radical 100 mbar = 10kPA = 1mWS Example: 5.5 - Target: presetting - Given: - RADICAL radiator: K1, Height 600, Length 700 - factory fitted valve: 4361 - preset: 5.5 - at 75/65/20°C - 776 Watt >>> 8 - ∆ t = 10°C (=75-65) - pressure drop: - ∆ p = 100mbar - selected tuning range: - 2K (see table) - Solution: presetting according to table 4361: 8 Valve needs to be re-adjusted to setting 8 116 4361 4361 7200 6500 5300 4800 3800 4000 3600 3200 3400 3000 2800 2600 2200 2400 1800 2000 1600 1400 1200 900 1000 800 600 700 5 6 7 8 3 4 5 6 1 3 4 6 500 300 3 1 1 400 200 250 . Q [W ] 4361 Valve re-adjustment 2.5 Standard valve 4360 Max. 2 K presetting 4.5 7200 6800 5300 6500 4800 4000 3800 3600 3400 3200 3000 2800 2600 2200 2400 1800 2000 1600 1400 1200 1000 7 7 8 6 6 7 7 8 1 1 1 1 2 2 2 3 3 3 4 5 5 6 6 7 8 8 100 1 1 1 1 1 2 2 2 2 3 3 4 4 5 5 6 6 6 7 7 7 8 8 150 1 1 1 1 1 2 2 2 2 3 3 3 4 4 5 5 5 6 6 6 6 7 8 20 50 100 150 1 1 1 1 1 1 1 1 1 2 2 2 2 1 1 1 2 1 1 1 1 3 3 3 4 5 2 2 2 3 3 2 2 2 2 3 5 5 6 6 7 3 4 4 5 5 3 3 3 4 4 7 7 8 5 5 6 4 4 5 8 6 6 5 5 7 8 6 7 8 50 100 150 1 40 1 1 1 1 1 1 1 1 1 2 2 2 2 1 1 1 1 2 1 1 1 1 1 2 3 3 3 3 2 2 2 2 2 1 2 2 2 2 3 4 4 2 3 3 2 2 2 4 5 3 3 2 3 5 6 7 7 8 4 4 5 5 6 3 3 4 4 5 800 700 900 600 5 6 7 8 4 5 5 6 6 3 4 4 5 5 500 3 3 4 5 2 2 3 3 2 2 2 3 300 3 2 2 400 1 1 1 2 2 1 1 1 1 2 1 1 1 1 . Q [W ] 250 200 4360 D t [K] Dp [mbar] 10 50 100 150 50 15 8 6 100 mbar = 10kPA = 1mWS Energy Saving - Radical 8 Example: 4.5 - Target: presetting - Given: - RADICAL radiator: K2, Height 600, Length 1200 - factory fitted valve: 4360 - preset: 4.5 - 60/40/20°C - 997 Watt - pressure drop: - ∆ p = 100mbar >>> “2” - selected tuning range - 2K (see table) - SOLUTION: PRESETTING ACCORDING TO TABLE 4360: “2“ 4360 4360 117 Pressure drop diagram Fine tuning valve 4361 Radiators without connection accessories 5.5 Information supplied by Heimeier 30 300 20 200 Pressure loss ∆p [kPa] 3 4 6 5 7 8 100 5 50 3 30 2 20 1 10 0,5 5 0,3 3 0,2 2 0,1 2 3 5 10 20 50 30 100 200 Fine presetting Radiator with integrated valves without connection fitting Thermostatic insert 1 Energy Saving - Radical 1 2 2 3 4 5 6 7 8 p-band Kv -Value [m3/h] 0,05 0,06 0,07 0,08 0,10 0,11 0,12 p-band xp2,0 K Kv -Value [m3/h] 0,06 0,06 0,08 0,09 0,11 0,15 0,18 0,26 kvs-Value [m3/h] 0,06 0,07 0,08 0,10 Flow tolerance 42 ± [%] 42 37 36 0,12 0,17 35 32 300 1 500 Pressure loss ∆p [mbar] Fine presetting 10 Thermostatic insert and thermostatic head p-band [xp] 2,0 K Permissible operating temperature Permissible operating pressure TB * ) [°C] PB [bar] 120 10 Permissible differential pressure at which the valve still closes ∆p [bar] 0,14 30 Given: Solution: 118 2,7 3,5 10 With protective cap or actuator 100°C Calculation example Setting range Heat flow Temperature spread Pressure loss, radiator, with integrated valves Mass flow rate 4,0 0,25 0,50 *) Target: EMO 1/3 EMO EIB/LON · Q ∆t ∆pv · m = 350 W = 15 K (65/50 °C) = 32 mbar · 350 Q = = = 20 kg/h c ˙ ∆t 1,163 ˙15 Pressure drop diagram Standard valve 4360 Radiators without connection accessories 2.5 p-band[xp] 2,0 K Information supplied by Heimeier 30 300 20 200 Presetting 10 1 2 3 4 5 6 7 8 100 5 50 3 30 2 20 1 10 0,3 3 0,2 2 0,1 2 Radiator with integrated valves without connection fitting Thermostatic insert and thermostatic head p-band K v value [m3/h] p-band xp2,0 K K v value [m3/h] 3 5 20 10 50 30 100 200 Presetting Thermostatic insert 1 2 3 4 5 6 7 8 300 1 500 Permissible operating temperature Permissible operating pressure TB * ) [°C] PB [bar] 120 10 Permissible differential pressure at which the valve still closes ∆p [bar] 6 EMO 1/3 EMO EIB/LON Energy Saving - Radical 5 ∆p [mbar ] 0,5 Pressure loss Pressure loss ∆p [kPa] 4.5 k vsvalue [m3/h] Flow tolerance ± [%] *) With protective cap or actuator 100 °C. Calculation example Target: Setting range G iven: Heat f low Temperature spread Pressure loss, radiator with integrated valves Solution: Mass flow rate 8 · Q = 1135 W ∆t = 15 K (65/50 ° C) ∆pv = 30 mbar · 1135 Q · m = = = 65 kg/h c ˙ ∆t 1,163 ˙15 119 Stelrad Radical 50∆t (75/65/20°C) Height 300 500 600 K2 K1 Length mm Straight 10mm UIN Angle 10mm UIN Straight 15mm UIN Angle 15mm UIN Heat output Watts Btu/hr 1000 33111010S 33111010A 33111015S 33111015A 509 400 500 600 700 800 900 1000 1200 1400 1600 1800 2000 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 35110410S 35110510S 35110610S 36110410S 36110510S 36110610S - 35110410A 35110510A 35110610A 36110410A 36110510A 36110610A - 35110415S 35110515S 35110615S 36110415S 36110515S 36110615S - 35110415A 35110515A 35110615A 36110415A 36110515A 36110615A - 333 417 500 392 490 588 - Straight 10mm UIN Angle 10mm UIN Straight 15mm UIN Angle 15mm UIN Heat output Watts Btu/hr 1737 33221010S 33221010A 33221015S 33221015A 933 1136 1423 1706 1338 1672 2006 - 35220410S 35220510S 35220610S 35220710S 35220810S 35220910S 35221010S 35221210S 35221410S 35221610S 35221810S 35222010S 36220410S 36220510S 36220610S 36220710S 36220810S 36220910S 36221010S 36221110S 36221210S 36221410S 36221610S 36221810S 36222010S 35220410A 35220510A 35220610A 35220710A 35220810A 35220910A 35221010A 35221210A 35221410A 35221610A 35221810A 35222010A 36220410A 36220510A 36220610A 36220710A 36220810A 36220910A 36221010A 36221110A 36221210A 36221410A 36221610A 36221810A 36222010A 35220415S 35220515S 35220615S 35220715S 35220815S 35220915S 35221015S 35221215S 35221415S 35221615S 35221815S 35222015S 36220415S 36220515S 36220615S 36220715S 36220815S 36220915S 36221015S 36221115S 36221215S 36221415S 36221615S 36221815S 36222015S 35220415A 35220515A 35220615A 35220715A 35220815A 35220915A 35221015A 35221215A 35221415A 35221615A 35221815A 35222015A 36220415A 36220515A 36220615A 36220715A 36220815A 36220915A 36221015A 36221115A 36221215A 36221415A 36221615A 36221815A 36222015A 560 1911 701 2392 841 2869 981 3347 1121 3825 1261 4303 1401 4780 1681 5736 1961 6691 2242 7650 2522 8605 2802 9560 647 2208 809 2760 970 3310 1132 3862 1294 4415 1455 4964 1617 5517 1779 6070 1940 6619 2264 7725 2587 8827 2911 9932 3234 11034 3183 ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). 40∆t (65/55/20°C) Energy Saving - Radical Height 300 500 600 120 K2 K1 Length mm Straight 10mm UIN Angle 10mm UIN Straight 15mm UIN Angle 15mm UIN Heat output Watts Btu/hr 1000 33111010S 33111010A 33111015S 33111015A 381 400 500 600 700 800 900 1000 1200 1400 1600 1800 2000 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 35110410S 35110510S 35110610S 36110410S 36110510S 36110610S - 35110410A 35110510A 35110610A 36110410A 36110510A 36110610A - 35110415S 35110515S 35110615S 36110415S 36110515S 36110615S - 35110415A 35110515A 35110615A 36110415A 36110515A 36110615A - 249 312 374 293 367 440 - Straight 10mm UIN Angle 10mm UIN Straight 15mm UIN Angle 15mm UIN Heat output Watts Btu/hr 1299 33221010S 33221010A 33221015S 33221015A 969 2381 850 1064 1276 1000 1251 1501 - 35220410S 35220510S 35220610S 35220710S 35220810S 35220910S 35221010S 35221210S 35221410S 35221610S 35221810S 35222010S 36220410S 36220510S 36220610S 36220710S 36220810S 36220910S 36221010S 36221110S 36221210S 36221410S 36221610S 36221810S 36222010S 35220410A 35220510A 35220610A 35220710A 35220810A 35220910A 35221010A 35221210A 35221410A 35221610A 35221810A 35222010A 36220410A 36220510A 36220610A 36220710A 36220810A 36220910A 36221010A 36221110A 36221210A 36221410A 36221610A 36221810A 36222010A 35220415S 35220515S 35220615S 35220715S 35220815S 35220915S 35221015S 35221215S 35221415S 35221615S 35221815S 35222015S 36220415S 36220515S 36220615S 36220715S 36220815S 36220915S 36221015S 36221115S 36221215S 36221415S 36221615S 36221815S 36222015S 35220415A 35220515A 35220615A 35220715A 35220815A 35220915A 35221015A 35221215A 35221415A 35221615A 35221815A 35222015A 36220415A 36220515A 36220615A 36220715A 36220815A 36220915A 36221015A 36221115A 36221215A 36221415A 36221615A 36221815A 36222015A 419 524 629 734 839 943 1048 1257 1467 1677 1886 2096 484 605 726 847 968 1088 1210 1331 1451 1693 1935 2177 2419 1429 1789 2146 2504 2861 3218 3576 4290 5005 5722 6437 7151 1651 2065 2476 2889 3303 3713 4127 4540 4951 5778 6602 7429 8254 Stelrad Radical 30∆t (55/45/20°C) Height 300 500 600 K2 K1 Length mm Straight 10mm UIN Angle 10mm UIN Straight 15mm UIN Angle 15mm UIN Heat output Watts Btu/hr 1000 33111010S 33111010A 33111015S 33111015A 262 400 500 600 700 800 900 1000 1200 1400 1600 1800 2000 400 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 35110410S 35110510S 35110610S 36110410S 36110510S 36110610S - 35110410A 35110510A 35110610A 36110410A 36110510A 36110610A - 35110415S 35110515S 35110615S 36110415S 36110515S 36110615S - 35110415A 35110515A 35110615A 36110415A 36110515A 36110615A - 171 215 258 202 252 303 - Straight 10mm UIN Angle 10mm UIN Straight 15mm UIN Angle 15mm UIN Heat output Watts Btu/hr 894 33221010S 33221010A 33221015S 33221015A 480 1639 585 733 879 689 861 1033 - 35220410S 35220510S 35220610S 35220710S 35220810S 35220910S 35221010S 35221210S 35221410S 35221610S 35221810S 35222010S 36220410S 36220510S 36220610S 36220710S 36220810S 36220910S 36221010S 36221110S 36221210S 36221410S 36221610S 36221810S 36222010S 35220410A 35220510A 35220610A 35220710A 35220810A 35220910A 35221010A 35221210A 35221410A 35221610A 35221810A 35222010A 36220410A 36220510A 36220610A 36220710A 36220810A 36220910A 36221010A 36221110A 36221210A 36221410A 36221610A 36221810A 36222010A 35220415S 35220515S 35220615S 35220715S 35220815S 35220915S 35221015S 35221215S 35221415S 35221615S 35221815S 35222015S 36220415S 36220515S 36220615S 36220715S 36220815S 36220915S 36221015S 36221115S 36221215S 36221415S 36221615S 36221815S 36222015S 35220415A 35220515A 35220615A 35220715A 35220815A 35220915A 35221015A 35221215A 35221415A 35221615A 35221815A 35222015A 36220415A 36220515A 36220615A 36220715A 36220815A 36220915A 36221015A 36221115A 36221215A 36221415A 36221615A 36221815A 36222015A 288 361 433 505 577 649 722 866 1010 1155 1299 1443 333 417 500 583 666 749 833 916 999 1166 1332 1499 1666 984 1232 1478 1724 1970 2216 2462 2954 3446 3940 4432 4924 1137 1432 1704 1989 2274 2557 2841 3126 3409 3978 4546 5115 5683 Each code includes the radiator of choice, with a hydro block and coupling piece. 2 hydro blocks are available; either straight configuration for pipes coming from the floor or angle configuration for pipes coming from the wall. 2 coupling pieces are available, either 10mm or 15mm to connect the H Block to flow and return pipe. Type Height W/m at 75/65/20 n-coefficients Heated Surface Area (m²/m) Weight (kg/m) Water Contents (l/m) K1 300 509 1.32 2.09 9.31 1.89 500 833 1.30 3.80 16.24 2.80 Energy Saving - Radical EN 442 Certification Data - CETIAT tested in accordance with BS EN 442 K2 600 980 1.29 4.66 19.70 3.25 300 933 1.30 3.51 16.50 3.70 500 1401 1.30 6.33 27.17 5.83 600 1617 1.30 7.74 32.50 6.90 121 Simple and efficient installation across the whole system. K1 K2 K1 - right K2 - left K3 - right ¾” 50 2x ¾” 50 L/2 L/2 Energy Saving - Radical L Radiator on short bracket side K1 (T11) K2 (T22) 83 61 51 122 124 100 73 Radiator on long bracket side K1 (T11) K2 (T22) 94 61 62 135 100 84 SECTION 25 FRONT 2" SECTION 1 25 1 25 SECTION ½“ FRONT K2 front elevation 2" K1 front elevation K1 A 117 150 85 400 500-1100 A 85 A 60 L L: 400-1600 K2 A A 133 133 267 267 ** 60 ** 3rd. lug in radiator centre (half length) 85 L 400 500-1100 1200-1600 1800-2000 ** 85 A L: 400-1600 L/2 A Energy Saving - Radical 60 85 85 A L: 1800-2000 123 Radical mounting template Using the mounting template for the bottom The radiator is mounted after all the finishing connection of Radical radiators offers important work, which guarantees a pristine condition advantages during the installation, e.g. leak on commissioning. testing the system without a mounted radiator. The mounting template consists of a bridging piece The mounting template replaces the radiator during with 2 connections of 3⁄4" external thread on a centre the installation, which reduces the total installing cost. distance of 50mm. As the wall distance depends Finishing tasks such as painting, tiling and applying on the radiator type, the mounting template offers wallpaper no longer require the removal and multiple positions according to the available brackets. remounting of the radiator. 35-115mm Energy Saving - Radical ? 115-155mm UIN: 9223 124 Radical mounting template To mount of the template on Connect the plumbing the wall, the plumbing should to the template and have the correct wall distance. conduct the leak test. 1 2 Once the concrete floor is Mount the brackets against the finished the L-shaped part (and the wall and remove the bridging part extension) can be removed in order before the radiator can be installed. to paint, tile, to apply wallpaper. Note: Brackets should be mounted ATTENTION: the bridging part before removal of the bridging part, must remain on the plumbing to to eliminate any possibility of prevent pollution of the tubes. 3 4 pollution. ATTENTION: the mounting template has a ¾" ext eurocone thread, for radiators with a ½" INT bottom connection, a ½" EXT x ¾" EXT piece is necessary. 5 The mounting template can be used for tubes coming from the floor, as Energy Saving - Radical For 1⁄2" INT - bottom connection (right, centre or left) well as for tubes coming from the wall. XXXXX 125 Radical Hydro Block connections 2-pipe connections for bottom connection (¾" EXT Eurocone or ½" INT): • Lock function • Casing in white high performance plastic (similar to RAL 9016) • Straight or angular version • Maximum operating temperature: 90°C UIN: 10mm 363000210A UIN: 10mm 363000210S UIN: 15mm 363000215A UIN: 15mm 363000215S - angular version - with drain 50 50 - not included - parts unlock drain function For ¾" EXT Eurocone bottom connection (centre): ¾" Energy Saving - Radical ¾" ¾" 32 58 ¾" - straight version - with drain - not included - parts unlock drain function 126 • Maximum operating pressure: 6 bar ¾" 26 50 Safety Stelrad has created a range of Low Surface Temperature radiators which provide the perfect solution for all specification requirements in safety critical environments. The complete choice Stelrad LST range offers you the flexibility you need The first coat of paint is applied by electrophoresis and the radiator is then stoved and cooled • The LST Standard leaves you free to specify your preferred controls • Followed by a second powder coat in warm white, the emitter then goes through a final curing stage. It is then allowed to cool prior to packaging • The LST Plus and LST i Plus offer an integral remote sensing thermostat valve, the highly specified Danfoss RAS-D Remote Sensor • All exposed painted surfaces are finished in a long lasting anti-bacterial coating • The LST Vertical is ideal where space is at a premium LST Plus & LST i Plus • An arthritic adaptor is supplied as standard for less able environments - along with a lockshield valve which can only be adjusted with a 6mm Allen key, hidden with a neat metal dust cover to discourage unauthorised tampering. (excludes LST Standard) Remote sensing thermostatic valve The complete package • Special tools are not required, as the valve is gland seal removable • Every Stelrad LST radiator is supplied with an attractive, flat panel outer casing, which is totally reversible to allow piping flexibility • Simple and quick to install, the casing is held by security fittings with a unique seam fixing bracket system to prevent unauthorised access to the emitter accommodated inside • For added protection, the smooth surface is coated in anti-bacterial paint • The emitter provides high outputs through convection for outstanding heating performance • Controlled independent laboratory testing ensures that each emitter is guaranteed to perform to a maximum working pressure of 116 psi (8 bar) and conform to BS EN 442, the European Standard for radiators • The Danfoss RAS-D Remote Sensor is designed specifically for commercial heating systems and can be pre-set to allow adjustment of room temperature between 5°C and 26°C • Suitable for both 1⁄2" steel and 15mm copper piping, with left or right hand, same end connections for flow and return, gives flexibility of installation Lockshield valve • Able to withstand 10 bar static pressure, the valve has a drain tap adaptor available, which can also be used as a filling point • Mandatory fittings should be used in order to comply with current water regulations Connections • 2 x 1⁄2" connections as standard, complete with Danfoss remote sensing thermostatic radiator valve, pre-piped with 2 x 1⁄2" BSP connections at 50mm centres positioned at either left or right of the casing • All specified components required supplied in one robust package Anti-bacterial paint cleaning process before the paint is applied. This involves several rinsing stages, including an iron phosphate and demineralisation phase Safety • Every LST emitter is subjected to a multi-stage CPD BIM For further information and advice call 0844 543 6200 127 LST Standard, LST Plus, LST i Plus & LST Vertical temperature table For systems not operating at ∆t50 the factors in the table below should be applied. The output of a given radiator can be obtained by multiplying the quoted ∆t50 output by the operating factor. Conversely, to derive a non ∆t50 output, divide the heat output required by the relevant operation factor. This ‘∆t50 equivalent output’ can then be used to select a radiator from the standard tables. ∆t °C Operating Factor ∆t °F Operating Factor 5 0.050 10 0.057 10 0.123 20 0.142 15 0.209 30 0.240 20 0.304 40 0.348 25 0.406 50 0.466 30 0.515 60 0.590 35 0.629 70 0.721 40 0.748 80 0.858 45 0.872 90 1.000 50 1.000 100 1.147 55 1.132 110 1.298 60 1.267 120 1.454 65 1.406 130 1.613 70 1.549 150 1.776 75 1.694 - - Water treatment On completion of the installation, the system should be properly flushed and filled in accordance with the British Standard Code of Practice BS 7593:2006 for the Treatment of Water in Domestic Hot Water Central Heating Systems, Part L of Building Regulations and Good Practice Guidance for Scotland. After installation of a new Stelrad radiator the central heating system should be cleaned and flushed with cleaner to remove existing contaminants, flux residue and other installation debris which, if left, can cause damage to the new radiator. Afterwards, treat the system with an inhibitor to ensure long term protection against corrosion and limescale. A comprehensive range of quality chemicals including inhibitors, cleaners, leak sealers and noise reducers that protect and maintain central heating systems can be obtained from: Sentinel Performance Solutions Ltd The Heath Business & Technical Park, Runcorn, Cheshire WA7 4QX Tel: 01928 588 330 (UK) www.sentinel-solutions.net Testing and operating pressures Fernox - Cookson Electronics, Forsyth Road, Sheerwater, Woking, Surrey GU21 5RZ www.fernox.com Caution To ensure that the emitter complies with all aspects of the NHS guidance for “Safe hot water and surface temperature”, Stelrad recommends that a maximum flow temperature of 80° be used with a 20° drop across the system. Safety Single feed, indirect cylinders are not recommended as should interchange of water occur, fresh aerated water would enter the heating system, resulting in corrosion. Example: Exact output at ∆t50 = 2000 Btu/hr Output at ∆t30 = 2000 x 0.515 = 1030 Btu/hr Average coefficient of 130 is used in the example above All models are high pressure tested to withstand 152.3 psi (10.5 bar). Strictly controlled independent laboratory testing ensures that all Stelrad radiators are guaranteed to perform to a maximum working pressure of 116 psi (8 bar) at a maximum temperature of 95°C. All conform to BS EN 442 - the European Standard for radiators. 128 When designing for domestic systems we recommend that the Stelrad LST range be used only in heating systems complying with the British Standard Code of Practice for Central Heating for Domestic Premises BS EN 12828:2003 and BS EN 12831:2003. Pressure drops Stelrad LST Range Standard K1 50 Δt (75/65/20°C) Casing Height 500 650 800 Casing Length mm Emitter Height mm Emitter Length mm UIN 560 760 960 1160 1360 1560 1760 1960 560 760 960 1160 1360 1560 1760 1960 560 760 960 1160 1360 1560 1760 1960 300 300 300 300 300 300 300 300 450 450 450 450 450 450 450 450 600 600 600 600 600 600 600 600 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 145000 145001 145002 145003 145004 145005 145006 145007 145024 145025 145026 145027 145028 145029 145030 145031 145048 145049 145050 145051 145052 145053 145054 145055 P+ Heat output Watts Btu/hr 196 293 391 489 587 685 782 880 290 435 580 725 870 1015 1160 1305 365 548 730 913 1096 1278 1461 1643 669 1000 1334 1668 2003 2337 2668 3003 989 1484 1979 2474 2968 3463 3958 4453 1245 1870 2493 3115 3740 4361 4985 5606 UIN 145008 145009 145010 145011 145012 145013 145014 145015 145032 145033 145034 145035 145036 145037 145038 145039 145056 145057 145058 145059 145060 145061 145062 145063 K2 Heat output Watts Btu/hr 284 426 568 710 852 994 1136 1278 386 580 773 966 1159 1352 1546 1739 501 751 1002 1252 1502 1753 2003 2254 969 1454 1938 2423 2907 3392 3876 4361 1317 1979 2637 3296 3955 4613 5275 5933 1709 2562 3419 4272 5125 5981 6837 7691 UIN 145016 145017 145018 145019 145020 145021 145022 145023 145040 145041 145042 145043 145044 145045 145046 145047 145064 145065 145066 145067 145068 145069 145070 145071 Heat output Watts Btu/hr 348 522 696 870 1044 1218 1392 1566 478 717 956 1195 1434 1673 1912 2151 615 922 1230 1537 1844 2152 2459 2767 1187 1781 2375 2968 3562 4156 4750 5343 1631 2446 3262 4077 4893 5708 6524 7341 2098 3146 4197 5244 6295 7343 8393 9441 ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). 40 Δt (65/55/20°C) Casing Height 500 650 800 Casing Length mm Emitter Height mm Emitter Length mm 560 760 960 1160 1360 1560 1760 1960 560 760 960 1160 1360 1560 1760 1960 560 760 960 1160 1360 1560 1760 1960 300 300 300 300 300 300 300 300 450 450 450 450 450 450 450 450 600 600 600 600 600 600 600 600 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 UIN P+ Heat output Watts Btu/hr 145000 147 145001 219 145002 292 145003 366 145004 439 145005 512 145006 585 145007 658 145024 217 145025 325 145026 434 145027 542 145028 651 145029 759 145030 868 145031 976 145048 273 145049 410 145050 546 145051 683 145052 820 145053 956 145054 1093 145055 1229 500 Btu/hr 748 998 1248 1498 1748 1996 2246 740 1110 1480 1850 2220 2590 2961 3331 932 1399 1863 2330 2797 3262 3729 4193 UIN 145008 145009 145010 145011 145012 145013 145014 145015 145032 145033 145034 145035 145036 145037 145038 145039 145056 145057 145058 145059 145060 145061 145062 145063 K2 Heat output Watts Btu/hr 212 319 425 531 637 744 850 956 289 434 578 723 867 1011 1156 1301 375 562 749 936 1123 1311 1498 1686 725 Btu/hr 1087 1450 1812 2174 2537 2899 3262 985 1480 1973 2465 2958 3451 3946 4438 1279 1917 2557 3195 3833 4474 5112 5753 UIN 145016 145017 145018 145019 145020 145021 145022 145023 145040 145041 145042 145043 145044 145045 145046 145047 145064 145065 145066 145067 145068 145069 145070 145071 Heat output Watts Btu/hr 260 390 521 651 781 911 1041 1171 358 536 715 894 1073 1251 1430 1609 460 690 920 1150 1379 1610 1839 2070 888 1332 1776 2220 2664 3109 3553 3997 1220 1830 2440 3050 3660 4270 4880 5490 1570 2353 3139 3923 4706 5492 6276 7062 Safety - LST Standard K1 129 Stelrad LST Range Standard K1 30 Δt (55/45/20°C) Casing Height 500 650 800 Casing Length mm Emitter Height mm Emitter Length mm UIN 560 760 960 1160 1360 1560 1760 1960 560 760 960 1160 1360 1560 1760 1960 560 760 960 1160 1360 1560 1760 1960 300 300 300 300 300 300 300 300 450 450 450 450 450 450 450 450 600 600 600 600 600 600 600 600 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 145200 145201 145202 145203 145204 145205 145206 145207 145208 145209 145210 145211 145212 145213 145214 145215 145216 145217 145218 145219 145220 145221 145222 145223 P+ Heat output Watts Btu/hr 101 151 201 252 302 353 403 453 149 224 299 373 448 523 597 672 188 282 376 470 564 658 752 846 344 515 687 859 1031 1204 1374 1546 510 764 1019 1274 1529 1784 2038 2293 641 963 1283 1604 1926 2246 2567 2887 UIN K2 Heat output Watts Btu/hr 145248 146 145249 219 145250 293 145251 366 145252 439 145253 512 145254 585 145255 658 145256 199 145257 299 145258 398 145259 497 145260 597 145261 696 145262 796 145263 896 145264 258 145265 387 145266 516 145267 645 145268 774 145269 903 145270 1032 145271 1161 499 749 998 1248 1497 1747 1996 2246 678 1019 1358 1697 2037 2376 2717 3056 880 1320 1761 2200 2639 3080 3520 3961 Heat output Watts Btu/hr UIN 145224 145225 145226 145227 145228 145229 145230 145231 145232 145233 145234 145235 145236 145237 145238 145239 145240 145241 145242 145243 145244 145245 145246 145247 179 269 358 448 538 627 717 806 246 369 492 615 739 862 985 1108 317 475 633 792 950 1108 1266 1425 611 917 1223 1529 1834 2140 2446 2752 840 1260 1680 2100 2520 2940 3360 3780 1081 1620 2161 2701 3240 3781 4321 4862 EN 442 Certification Data - CETIAT tested in accordance with BS EN 442 Type Safety - LST Standard Casing Height Emitter Height W/m at 75/65/20 n-coefficients Heated Surface Area (m²/m) Weight (kg/m) Water Contents (l/m) 130 K1 500 300 489 1.19 2.09 17.80 1.89 650 450 725 1.25 3.37 23.50 2.57 P+ 800 600 913 1.34 4.66 29.40 3.25 500 300 710 1.24 2.44 22.70 3.70 650 450 966 1.27 3.84 30.72 5.15 K2 800 600 1252 1.31 5.24 38.40 6.60 500 300 870 1.27 3.51 24.40 3.70 650 450 1195 1.30 5.62 33.30 5.15 800 600 1537 1.32 7.74 42.50 6.60 LST Standard wall fixings & bracket positions Casing Height 500 650 800 195 (7.67) 134 (5.27) Casing Height Casing Length 560 760 960 100 (3.93) 195 (7.67) 102 (4.01) 24 (0.94) All dimensions in mm. Inches in brackets. 165 (6.49) 165 (6.49) Casing Length 165 (6.49) 24 (0.94) 165 (6.49) B Casing Length Safety - LST Standard Casing Height 500 650 800 134 (5.27) B 475 575 675 775 875 195 (7.67) 102 (4.01) A 445 545 645 745 845 Casing Height Casing Length 1160 1360 1560 1760 1960 A 100 (3.93) 195 (7.67) 131 LST Standard connection options All dimensions in mm. Inches in brackets. 119 (4.68) 25 (0.98) A 250 400 550 A Casing Height 500 650 800 Casing Height 132 (5.19) Safety - LST Standard LST Standard piping options 132 Stelrad LST Range Plus Vertical 50 Δt (75/65/20°C) Casing Height Casing Length mm Emitter Height mm Emitter Length mm UIN 2110 560 660 760 1800 1800 1800 400 500 600 142241 142242 142243 Heat output Watts Btu/hr 1271 1588 1855 4336 5418 6329 ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). W LST Plus Vertical installation instructions All dimensions in mm. Inches in brackets. Present casing and bottom bracket to the wall and mark drill hole positions. Fit pipework and valve connections to the radiators. 560, 660, or 760 195 (7.68) 195 (7.68) radiator indentation left Looking to the front of the radiator radiator indentation right 2086.5 (82.15) Looking to the front of the radiator L R indentation 1544 (60.79) 2x Bottom view Safety - LST Plus Vertical 257 (10.12) 459 (18.07) 404 (15.91) 17.5 (0.69) 359 (14.13) 165 (6.50) 133 LST Plus Vertical connection options All dimensions in mm. Inches in brackets. 132 (5.19) radiator indentation left Looking to the front of the radiator radiator indentation right Looking to the front of the radiator 243 (9.56) indentation Casing Length A 560 344 660 444 760 544 50 (1.96) A Safety - LST Plus Vertical Casing length 134 Bottom view Stelrad LST Range Plus K1 50 Δt (75/65/20°C) Casing Height 500* 650** 750*** *500 integral kick grille Casing Length mm Emitter Height mm Emitter Length mm UIN 650 850 1050 1250 1450 1650 1850 2050 650 850 1050 1250 1450 1650 1850 2050 650 850 1050 1250 1450 1650 1850 2050 300 300 300 300 300 300 300 300 400 400 400 400 400 400 400 400 500 500 500 500 500 500 500 500 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 142169 142170 142171 142172 142173 142174 142175 142176 142177 142178 142179 142180 142181 142182 142183 142184 142185 142186 142187 142188 142189 142190 142191 142192 P+ Heat output Watts Btu/hr 203 304 406 507 608 710 811 913 264 397 529 661 793 925 1058 1190 336 503 671 839 1007 1175 1342 1510 693 1037 1385 1730 2074 2423 2767 3115 901 1355 1805 2255 2706 3156 3610 4060 1146 1716 2289 2863 3436 4009 4579 5152 UIN 142217 142218 142219 142220 142221 142222 142223 142224 142225 142226 142227 142228 142229 142230 142231 142232 142233 142234 142235 142236 142237 142238 142239 142240 **650 height includes 150mm removable kick grille K2 Heat output Watts Btu/hr 290 435 580 725 870 1015 1160 1305 388 581 775 969 1163 1357 1550 1744 461 692 922 1153 1384 1614 1845 2075 989 1484 1979 2474 2968 3463 3958 4453 1324 1982 2644 3306 3968 4630 5289 5951 1573 2361 3146 3934 4722 5507 6295 7080 UIN 142193 142194 142195 142196 142197 142198 142199 142200 142201 142202 142203 142204 142205 142206 142207 142208 142209 142210 142211 142212 142213 142214 142215 142216 Heat output Watts Btu/hr 362 542 723 904 1085 1266 1446 1627 456 685 913 1141 1369 1597 1825 2054 558 837 1116 1395 1674 1953 2232 2511 1235 1849 2467 3084 3702 4320 4934 5551 1556 2337 3115 3893 4671 5449 6227 7008 1904 2856 3808 4760 5712 6664 7616 8568 ***750 height includes 150mm removable kick grille ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). 40 Δt (65/55/20°C) Casing Height 500* 650** 750*** *500 integral kick grille Casing Length mm Emitter Height mm Emitter Length mm UIN 650 850 1050 1250 1450 1650 1850 2050 650 850 1050 1250 1450 1650 1850 2050 650 850 1050 1250 1450 1650 1850 2050 300 300 300 300 300 300 300 300 400 400 400 400 400 400 400 400 500 500 500 500 500 500 500 500 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 142169 142170 142171 142172 142173 142174 142175 142176 142177 142178 142179 142180 142181 142182 142183 142184 142185 142186 142187 142188 142189 142190 142191 142192 Heat output Watts Btu/hr Btu/hr 152 518 227 776 304 1036 379 1294 455 1552 531 1812 607 2070 683 2330 197 674 297 1013 396 1350 494 1687 593 2024 692 2361 791 2700 890 3037 858 251 376 1284 502 1713 628 2141 753 2570 879 2999 1004 3425 1129 3854 P+ UIN 142217 142218 142219 142220 142221 142222 142223 142224 142225 142226 142227 142228 142229 142230 142231 142232 142233 142234 142235 142236 142237 142238 142239 142240 **650 height includes 150mm removable kick grille Heat output Watts Btu/hr Btu/hr 217 740 325 1110 434 1480 542 1850 651 2220 759 2590 868 2961 976 3331 290 990 435 1483 580 1978 725 2473 870 2968 1015 3463 1159 3956 1305 4451 345 1177 518 1766 690 2353 862 2943 1035 3532 1207 4119 1380 4709 1552 5296 K2 UIN 142193 142194 142195 142196 142197 142198 142199 142200 142201 142202 142203 142204 142205 142206 142207 142208 142209 142210 142211 142212 142213 142214 142215 142216 Heat output Watts Btu/hr 271 405 541 676 812 947 1082 1217 341 512 683 853 1024 1195 1365 1536 417 626 835 1043 1252 1461 1670 1878 924 1383 1845 2307 2769 3231 3690 4152 1164 1748 2330 2912 3494 4076 4658 5242 1424 2136 2848 3560 4272 4984 5696 6409 Safety - LST Plus K1 ***750 height includes 150mm removable kick grille 135 Stelrad LST Range Plus K1 30 Δt (55/45/20°C) Casing Height 500* 650** 750*** *500 integral kick grille Casing Length mm Emitter Height mm Emitter Length mm UIN 650 850 1050 1250 1450 1650 1850 2050 650 850 1050 1250 1450 1650 1850 2050 650 850 1050 1250 1450 1650 1850 2050 300 300 300 300 300 300 300 300 400 400 400 400 400 400 400 400 500 500 500 500 500 500 500 500 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 142169 142170 142171 142172 142173 142174 142175 142176 142177 142178 142179 142180 142181 142182 142183 142184 142185 142186 142187 142188 142189 142190 142191 142192 P+ Heat output Watts Btu/hr 105 157 209 261 313 366 418 470 136 204 272 340 408 476 545 613 173 259 346 432 519 605 691 778 357 534 713 891 1068 1248 1425 1604 464 698 930 1161 1393 1625 1859 2091 590 884 1179 1474 1769 2065 2358 2653 UIN Heat output Watts Btu/hr 142217 149 142218 224 142219 299 142220 373 142221 448 142222 523 142223 597 142224 672 142225 200 142226 299 142227 399 142228 499 142229 599 142230 699 142231 798 142232 898 142233 237 142234 356 142235 475 142236 594 142237 713 142238 831 142239 950 142240 1069 **650 height includes 150mm removable kick grille K2 510 764 1019 1274 1529 1784 2038 2293 682 1021 1362 1703 2044 2384 2724 3065 810 1216 1620 2026 2432 2836 3242 3646 Safety - LST Plus 136 500 300 507 1.26 2.09 9.31 1.89 K1 650 400 661 1.35 2.95 12.78 2.57 750 500 839 1.32 3.80 16.24 3.25 500 300 727 1.32 2.44 14.29 3.70 P+ 650 400 969 1.32 3.37 19.46 5.15 750 500 1153 1.34 4.31 24.63 6.60 500 300 904 1.31 3.51 16.18 3.70 142193 142194 142195 142196 142197 142198 142199 142200 142201 142202 142203 142204 142205 142206 142207 142208 142209 142210 142211 142212 142213 142214 142215 142216 Heat output Watts Btu/hr 186 279 372 466 559 652 745 838 235 353 470 588 705 822 940 1058 287 431 575 718 862 1006 1149 1293 636 952 1270 1588 1907 2225 2541 2859 801 1204 1604 2005 2406 2806 3207 3609 981 1471 1961 2451 2942 3432 3922 4412 ***750 height includes 150mm removable kick grille EN 442 Certification Data – BSRIA tested in accordance with BS EN 442 Type Overall Height Emitter Height W/m at 80/60/20 n-coefficients Heated Surface Area (m2/m) Weight (kg/m) Water Contents (l/m) UIN K2 650 400 1141 1.34 4.92 22.87 5.15 750 500 1395 1.36 6.33 28.93 6.60 LST Plus wall fixings and bracket positions (height 650mm and 750mm) 24 (0.94) All dimensions in mm. Inches in brackets. 270 (10.63) 150 (5.90) 102 (4.01) 184 (7.24) Casing Height 650 750 Casing Height Casing Length 650 850 1050 100 (3.93) 270 (10.63) 240 (9.44) 240 (9.44) 240 (9.44) 150 (5.90) 100 (3.93) 270 (10.63) 184 (7.24) Casing Height 650 750 Casing Height Casing Length A B 1250 415 445 1450 515 545 A 102 (4.01) 270 (10.63) 24 (0.94) Casing Length 240 (9.44) B Casing Length 410 (16.14) 410 (16.14) 240 (9.44) Casing Length Safety - LST Plus 240 (9.44) 150 (5.90) 102 (4.01) Casing Height 650 750 184 (7.24) Casing Height Casing Length 1650 1850 2050 270 (10.63) 410 (16.14) 24 (0.94) 410 (16.14) 100 (3.93) 270 (10.63) 137 LST Plus floor mounting bracket positions (height 500mm) 24 (0.94) All dimensions in mm. Inches in brackets. 270 (10.63) 134 (5.27) 102 (4.01) 500 (19.68) Casing Length 650 850 1050 100 (3.93) 270 (10.63) 240 (9.44) 240 (9.44) 100 (3.93) B 445 545 270 (10.63) 134 (5.27) 500 (19.68) Casing Length A 1250 415 1450 515 A 102 (4.01) 270 (10.63) 24 (0.94) Casing Length 240 (9.44) 240 (9.44) B Casing Length 410 (16.14) 270 (10.63) 410 (16.14) 134 (5.27) 100 (3.93) 500 (19.68) Casing Length 1650 1850 2050 102 (4.01) 24 (0.94) 270 (10.63) 240 (9.44) 410 (16.14) 410 (16.14) Safety - LST Plus Casing Length 138 240 (9.44) LST Plus connection options (height 650 and 750mm) All dimensions in mm. Inches in brackets. 35 (1.37) 170 (6.69) A Casing Height 137 (5.39) Casing Height A 650 350 750 450 25 (0.98) 132 (5.19) Control on right-hand side 60 (2.36) 50 (1.96) Control on left-hand side 137 (5.39) Pipe configurations 35 (1.37) Safety - LST Plus 50 (1.96) 139 LST Plus connection options (height 500mm) All dimensions in mm. Inches in brackets. 132 (5.19) 25 (0.98) A 35 (1.37) 50 (1.96) 87 (3.42) Control on left-hand side 35 (1.37) Safety - LST Plus 50 (1.96) 140 170 (6.69) 87 (3.42) Casing Height A 500 250 Casing Height Control on right-hand side 60 (2.36) Stelrad LST Range i Plus K1 50 Δt (75/65/20°C) Casing Height 500 650 800 Casing Length mm Emitter Height mm Emitter Length mm UIN 650 850 1050 1250 1450 1650 1850 2050 650 850 1050 1250 1450 1650 1850 2050 650 850 1050 1250 1450 1650 1850 2050 300 300 300 300 300 300 300 300 450 450 450 450 450 450 450 450 600 600 600 600 600 600 600 600 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 145200 145201 145202 145203 145204 145205 145206 145207 145208 145209 145210 145211 145212 145213 145214 145215 145216 145217 145218 145219 145220 145221 145222 145223 P+ Heat output Watts Btu/hr 196 293 391 489 587 685 782 880 290 435 580 725 870 1015 1160 1305 365 548 730 913 1096 1278 1461 1643 669 1000 1334 1668 2003 2337 2668 3003 989 1484 1979 2474 2968 3463 3958 4453 1245 1870 2493 3115 3740 4361 4985 5606 UIN 145248 145249 145250 145251 145252 145253 145254 145255 145256 145257 145258 145259 145260 145261 145262 145263 145264 145265 145266 145267 145268 145269 145270 145271 K2 Heat output Watts Btu/hr 284 426 568 710 852 994 1136 1278 386 580 773 966 1159 1352 1546 1739 501 751 1002 1252 1502 1753 2003 2254 969 1454 1938 2423 2907 3392 3876 4361 1317 1979 2637 3296 3955 4613 5275 5933 1709 2562 3419 4272 5125 5981 6837 7691 UIN 145224 145225 145226 145227 145228 145229 145230 145231 145232 145233 145234 145235 145236 145237 145238 145239 145240 145241 145242 145243 145244 145245 145246 145247 Heat output Watts Btu/hr 348 522 696 870 1044 1218 1392 1566 478 717 956 1195 1434 1673 1912 2151 615 922 1230 1537 1844 2152 2459 2767 1187 1781 2375 2968 3562 4156 4750 5343 1631 2446 3262 4077 4893 5708 6524 7341 2098 3146 4197 5244 6295 7343 8393 9441 ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). 40 Δt (55/45/20°C) Casing Height 500 650 800 Casing Length mm Emitter Height mm Emitter Length mm 650 850 1050 1250 1450 1650 1850 2050 650 850 1050 1250 1450 1650 1850 2050 650 850 1050 1250 1450 1650 1850 2050 300 300 300 300 300 300 300 300 450 450 450 450 450 450 450 450 600 600 600 600 600 600 600 600 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 UIN P+ Heat output Watts Btu/hr 145200 147 145201 219 145202 292 1145203 366 145204 439 145205 512 145206 585 145207 658 145208 217 145209 325 145210 434 145211 542 145212 651 145213 759 145214 868 145215 976 145216 273 145217 410 145218 546 145219 683 145220 820 145221 956 145222 1093 145223 1229 500 748 998 1248 1498 1748 1996 2246 740 1110 1480 1850 2220 2590 2961 3331 932 1399 1863 2330 2797 3262 3729 4193 UIN 145248 145249 145250 145251 145252 145253 145254 145255 145256 145257 145258 145259 145260 145261 145262 145263 145264 145265 145266 145267 145268 145269 145270 145271 K2 Heat output Watts Btu/hr 212 319 425 531 637 744 850 956 289 434 578 723 867 1011 1156 1301 375 562 749 936 1123 1311 1498 1686 725 1087 1450 1812 2174 2537 2899 3262 985 1480 1973 2465 2958 3451 3946 4438 1279 1917 2557 3195 3833 4474 5112 5753 UIN 145224 145225 145226 1145227 145228 145229 145230 145231 145232 145233 145234 145235 145236 145237 145238 145239 145240 145241 145242 145243 145244 145245 145246 145247 Heat output Watts Btu/hr 260 390 521 651 781 911 1041 1171 358 536 715 894 1073 1251 1430 1609 460 690 920 1150 1379 1610 1839 2070 888 1332 1776 2220 2664 3109 3553 3997 1220 1830 2440 3050 3660 4270 4880 5490 1570 2353 3139 3923 4706 5492 6276 7062 Safety - LST i Plus K1 141 Stelrad LST Range i Plus K1 30 Δt (55/45/20°C) Casing Height 500 650 800 Casing Length mm Emitter Height mm Emitter Length mm UIN 650 850 1050 1250 1450 1650 1850 2050 650 850 1050 1250 1450 1650 1850 2050 650 850 1050 1250 1450 1650 1850 2050 300 300 300 300 300 300 300 300 450 450 450 450 450 450 450 450 600 600 600 600 600 600 600 600 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 145200 145201 145202 145203 145204 145205 145206 145207 145208 145209 145210 145211 145212 145213 145214 145215 145216 145217 145218 145219 145220 145221 145222 145223 P+ Heat output Watts Btu/hr 101 151 201 252 302 353 403 453 149 224 299 373 448 523 597 672 188 282 376 470 564 658 752 846 344 515 687 859 1031 1204 1374 1546 510 764 1019 1274 1529 1784 2038 2293 641 963 1283 1604 1926 2246 2567 2887 UIN K2 Heat output Watts Btu/hr 145248 146 145249 219 145250 293 145251 366 145252 439 145253 512 145254 585 145255 658 145256 199 145257 299 145258 398 145259 497 145260 597 145261 696 145262 796 145263 896 145264 258 145265 387 145266 516 145267 645 145268 774 145269 903 145270 1032 145271 1161 499 749 998 1248 1497 1747 1996 2246 678 1019 1358 1697 2037 2376 2717 3056 880 1320 1761 2200 2639 3080 3520 3961 Heat output Watts Btu/hr UIN 145224 145225 145226 145227 145228 145229 145230 145231 145232 145233 145234 145235 145236 145237 145238 145239 145240 145241 145242 145243 145244 145245 145246 145247 179 269 358 448 538 627 717 806 246 369 492 615 739 862 985 1108 317 475 633 792 950 1108 1266 1425 611 917 1223 1529 1834 2140 2446 2752 840 1260 1680 2100 2520 2940 3360 3780 1081 1620 2161 2701 3240 3781 4321 4862 EN 442 Certification Data - CETIAT tested in accordance with BS EN442 Type Safety - LST i Plus Casing Height Emitter Height W/m at 75/65/20 n-coefficients Heated Surface Area (m²/m) Weight (kg/m) Water Contents (l/m) 142 K1 500 300 489 1.19 2.09 17.80 1.89 650 450 725 1.25 3.37 23.50 2.57 P+ 800 600 913 1.34 4.66 29.40 3.25 500 300 710 1.24 2.44 22.70 3.70 650 450 966 1.27 3.84 30.72 5.15 K2 800 600 1252 1.31 5.24 38.40 6.60 500 300 870 1.27 3.51 24.40 3.70 650 450 1195 1.30 5.62 33.30 5.15 800 600 1537 1.32 7.74 42.50 6.60 LST i Plus wall fixings and bracket positions All dimensions in mm. Inches in brackets. 100 (3.93) 270 (10.63) 134 (5.27) 102 (4.01) Casing Height 500 650 800 Casing Height Casing Length 650 850 1050 24 (0.94) 270 (10.63) 237 (9.33) 237 (9.33) Casing Length 24 (0.94) Casing Height 500 650 800 134 (5.27) 237 (9.33) 237 (9.33) B Casing Length Safety - LST i Plus B 448 548 648 748 848 100 (3.93) A 415 515 615 715 815 Casing Height Casing Length 1250 1450 1650 1850 2050 270 (10.63) A 102 (4.01) 270 (10.63) 143 LST i Plus connection options All dimensions in mm. Inches in brackets. 25 (0.98) A Casing Height 87 (3.42) Casing Height A 500 250 650 400 800 550 35 (1.37) 60 (2.36) 50 (1.96) 87 (3.42) Control on left-hand side 35 (1.37) Safety - LST i Plus 50 (1.96) 144 Pipe configurations 120 (4.72) 132 (5.19) Control on right-hand side LST Range Components LST Standard front case view. LST Standard inside the casing showing the emitter. LST Standard emitter, showing high level valve option (valve not included). LST Standard circular knockout for TRV. Oblong knockout for pipe. LST Plus inside the casing showing the emitter. LST Vertical front case view. LST i Plus front case view. LST i Plus inside the casing showing the emitter. LST Plus front case view. LST Plus and LST i Plus Components Optional cover cap to discourage unauthorised tampering. An arthritic adaptor is supplied as standard for special needs environments. Accommodated within the casing, the Stelrad LST Plus emitter, with TBSE valve arrangement and 2 x 1⁄2" BSP connections as standard. Connection arrangement bottom. Connection arrangement top. Save time and effort by using the Stelrad STARS program - the perfect solution for accurate sizing and design flexibility. www.starsapp.co.uk Includes Danfoss RA-2000 TRV and copper pipe configuration. The remote sensing thermostatic valve gives accuracy of operation and the limiting device is completely hidden to prevent the maximum temperature being exceeded. 145 Safety - LST Components The Stelrad STARS Heatloss Calculator contains an inbuilt U value calculator. colourful A shade for every room, for every interior. Opt for warm elegance, baroque ambience or modern minimalism. Below colours for: Caliente Towel Rail, Concord Towel Rail, Compact with Style, Planar and Swing Natural Colour NT110 Papyrus white NT120 Pearl white NT130 Champagne NT140 Beige NT150 Beige grey NT160 Pebble grey NT170 Quartz grey SN110 Cream white SN120 Cream SN130 Mocca SN140 Bordeaux SN150 Sepia SN160 Pale blue SN170 Black ML130 Blue grey ML140 Granite ML150 Cappuccino ML160 Terra brown ML170 Graphite black Metallic Colours ML110 Dove grey ML120 Titanium grey Colour Options RAL Colours A1004 Golden yellow A2003 Pastel orange A3002 Carmine red A3003 Robin red A5002 Ultramarine blue A6018 Yellow green A7001 Silver grey A7011 Iron grey A7016 Anthracite grey A7030 Stone grey A7035 Light grey A8017 Chocolate brown A9003 Signal white A9005 Jet black 146 Please note: When a coloured radiator or radiators over 2 metres have been ordered they cannot be cancelled or returned. All colour radiators have a 6 week lead time. colour charts our charts Stelrad colour c inspiration 5RAL 6019 RAL 6005 Metallics RAL 90 RAL 7030 3005 RAL 6027 RAL RAL6019 1013 RAL 1015 RAL RAL 7038 RAL 7036 RAL 60 RAL6034 9005RAL RAL 8017* BR 0002 RAL 6033 7* RAL 5014 Metallics RALClassic 9002Column * The Stelrad RAL 1015 RAL 7030 3005 RAL RAL6019 1013RAL RAL 7037 6027 RAL 6034 RAL 6033 RAL 7036 RAL RAL 8017* RAL RAL 1016 Meta range is not available in this50 BR 0002 BR 0004 colour. RAL 6020 RAL 5022 RAL 1013 6RAL3005 BR 00 With Stelrad, you can heat your home in colour. Choose from a full range ofRAL stylish9002 radiator colours. RAL 1015 RAL 6027 RAL 7015 6034 †The Stelrad Concord range 6020 RAL 7030 RAL 7037 RAL RALis 50 RAL6033 1016RAL RAL 1021 BR 6019 0007 RAL BR 0004 RAL Metallics not available in this colour. Below colours for: RAL 3005 RAL 7035 RAL 1013 RAL 1015 6005 RAL 5024 1RAL6027 RAL BR 00 RAL 9002 0002 The coloursBR shown are Classic Column, Concord, Vistaline and Ellipse RAL 6034 RAL 6019 6005 RAL 7037 RAL 7015 RAL RAL6020 1021RAL reproduced as 50 BR9005 0007 RAL 6033 RAL Metallics RAL 1004 as accuratelyRAL printing process willRAL allow10 6027 7038 RAL 7035 RAL RAL 3005 RALthis RAL 1015RAL 9002 RAL 5014 RAL 5002 4 BR 00 and are available to special RAL 6034 BR 0002 BR 0004 * The Stelrad Classic Columnorder only on specific products. RAL Colours RAL 9005 6019 RAL RAL 8017* 6033 RAL RAL 6005 RAL RAL 7015 6020 RAL 50 RAL 1004inRAL Metallics RAL 2008 range is not available this 5014 RAL 7035 RALcolour. 3005 RAL 6027 RAL 6034 RAL 1013 RAL 10 RAL 9002 7036 8RAL 5022 RAL 7038 RAL RAL 5010 BR 0002 BR 0004 BR 0007 RAL 6019 * The Stelrad†The Classic Column Metallics RAL 8017* 6033 RAL Stelrad Concord range is 5022 RAL 6020 RAL RAL 5014 RAL 1016 6005 RAL 9005 RAL RAL 2008 RAL 50 RAL 3017* range is not available in this RAL 7035 RAL 7038 RAL 7036 RALavailable 7030 7037 RAL 9005* not inRAL this colour. RAL 7015 RAL S RAL 1015 * The 90 colour. RAL 7038 RAL 6027 RAL 7030 RAL 6019 RAL 6034 RAL 7036 BR 0002 RAL 3005 RAL 1013 RAL 5024 BR 0004 BR 0007 RAL 9016 7* range The colours shown are RAL 6033 RAL 6020 †The Metallics colour Stelrad Concord range is 5022 RAL RAL 1021 6005 RAL 5024 RAL 8017*RAL 1016 RAL RAL 5014 reproduced as accurately RAL 90 RAL 3017*as RAL 3000 not availablethis in printing this colour. RAL 3005 RAL process will1013 allow *RAL The 9002 Stelrad †The Classic RAL 6034 RAL 7036 RAL 1015 St RAL 6033 RAL 7037 RAL 7030 RAL 6019 BR 0002 BR 0004 RAL 6027 BR 0007 5002 RAL 9010† 0RAL RAL and RAL are1004 available RAL to 2008 special RAL 3017 range is notMetal availab RAL 3000 8017 RAL 1016 RAL 1021 not av The colours shown are order only on specific products. RAL 6020 colour. RAL 6005 *RAL 1016 RAL 1021 RAL RAL 5014 RAL 1004 reproduced as accurately as 5022 RAL RAL00 90 RAL5024 3000RAL RAL5002 3003 BR The colo * The Stelrad Classic Column this printing process will allowRAL 1015 RAL 9002 †The Stelrad Concord RAL RAL 6019 RAL 1013 RAL 7030 3005 RAL 7015 RAL 6020 RAL 6033 RAL 7037 RAL 6027 BR 0004 RAL 6034 BR 0007 RAL 5010 reprodu range is notMetallics available in this and available to special 3 RALare9001 not available in this this prin colour. order5022 only on specific products. RAL 5014 RAL 6005 RAL RAL 5002 RAL 1004 RAL 2008 RAL 5010 RAL 5024 RAL 1021 RAL 3003 RAL 90 and 00 are BR RAL 3003 RAL 3005 RAL 6027 RAL 6034 RAL 6019 RAL 6033 RAL 6020 BR 0002 * The Stelrad Classic Column colours shown order on RAL6033 1015RAL RAL †The6005 Stelrad The Concord range is are 9002 RAL RAL RAL 7037 6027 RAL 7015 RAL RAL 9005 6020 3005 RAL 1013 BR 0007 RAL 6019 RAL 9016 range is not available in this reproduced as accurat RAL 6034 Metallics Stelrad colour char Stelrad colour charts elrad colour charts d colour charts colour charts olour charts our chart chart not available in this colour. printing process w RAL 2008 5022 RAL RAL 3017* 5024 RAL 5002 RAL 5010 RAL 9016 this RAL 5014 RAL RAL 1004 BR 00 BR are 0004 and The colours shown areavailable to sp BR 0002 RAL 9002 †The StelradRAL Concord rangeorder is only on specific Stelrad Classic Column RAL RAL* The 6020 RAL 7015 6034 RAL 5014 RAL 6005 RAL8017* 1013RAL reproduced as accurately as RAL 6033 1015 RAL 9010†RAL 9005 6027 RAL 6005 RAL 5014 RAL 5002 RAL 5024 RAL 5022 RAL 5010 not availableininthis this colour. RAL 9016** range is not available this printing process will allow RAL 6019 RAL 5024 RAL 5002 colour. BR to 0007 RAL 9016 RAL 3017* RAL RAL 3000 and 9010† available special RAL 2008 RAL 5010 RAL 5022 BR are 0004 The colours shown are order only on specific products. * 1016 The Stelrad Classic Column RAL 6005 9005 RAL 6019 RAL 1013 reproduced as accurately as RAL 1015 RAL 5022 RAL RAL 8017* RAL 5014 RAL 9002 RAL 6020 †RAL RAL 9001 †The Stelrad Concord range is BR 0002 range is not available in this 6034 this printing process will allow * The S not available in this colour. RAL 6033 RAL 5002 colour. RAL 5010 and are available to special 9010† RAL 3017* RAL 9010 RAL 3000 RAL 9001 RAL 3003 RAL 1013 RAL 9016 1015 RAL RAL 9002 RAL range BR9001 0007 BR RAL 0002 RAL 5024 order only on specific products. colour colour. Metallics Metallics Colour Options RAL 9002 RAL RALThe 5014 RAL 8017* 6033 RAL RAL1016 1015RAL colours shown 1021 RAL 5022 RAL 6005 †The Stelrad Concord range is areRAL 5024 BR 0004as reproduced as accurately * The Stelrad Classic MetallicRAL Colours 6019 not available in this colour. †The St 5010 *RAL 3000RAL RAL 9016 Metallics RAL6020 3003 RAL 9001 RAL 9010† this printing process allow Stelrad radiators are available in whitewill (RAL 9016) as standard, howeverrange is not availab BR 0004 not av the specific radiators identified are now available in a variety of colours. RAL 5002 colour. and are available to special Please note that once ordered, coloured radiators cannot be cancelled. The colours shown areRAL 5024 RAL 5002 RAL 5022 RAL 1016 6020 RAL RAL1021 9002RAL 1004 *RAL RAL 5014 The colours shown are reproduced as accurately as this process will BRas 0002 order only on as specific products. The colo reproduced accurately Metallics BR 0007 * The Stelrad†The Classic Column Stelrad Concord allow and can be made to order on the identified products. 6033 RAL 9016 RALthis 9010† reproduc BRprocess 0007will allow printing RAL 3003 RAL 9001 2765G Silver BR 0004 BR 0007*** range is Optia not available in this not available in this *Excel black **Standard white ***Colour for Arc, Wave and RAL 6005 this prin and are available to special BR 0002 RAL 5010 colour. RAL RAL 5024 RAL 5002 RAL 5010 RAL 1021 6005 RAL 1004 RAL 2008 RAL 5022 and are order only on 0004 specific products. BR The colours shown ar To request a colour chart and details of how to order please email marketing@stelrad.com order on Metallics †The Stelrad reproduced Concord range is RAL 9010†RAL 9001 as147accura 6020 not available in this colour. Glossary 148 Btu/hr British Thermal Unit per hour is the standard measurement used to state the amount of output of any heat generating device. Watts Is another measurement for heat output, 1 watt is equivalent to 3.412 Btu/hr. P1 Also known as Type 10, is a type of radiator with 1 radiator panel and no convection fins. K1 Also known as Type 11, is a type of radiator with 1 radiator panel and 1 set of convection fins. P+ Also known as Type 21, is a type of radiator with 2 radiator panels and 1 set of convection fins. K2 Also known as Type 22, is a type of radiator with 2 radiator panels and 2 sets of convection fins. K3 Also known as Type 33, is a type of radiator with 3 radiator panels and 3 sets of convection fins. ∆t Refers to the difference in temperature between the water circulating in the central heating system and that of the ambient temperature. It is important to use the correct ∆t when selecting your radiators, as the same radiator will have different outputs at different water temperatures. ∆t50 ∆t50 is the UK standard, however Stelrad also quote at lower levels for lower water temperature systems. Heat loss Is the amount of heat a room loses, it is therefore an important calculation when determining what size radiator is required to heat a room to the correct level. UIN Is the Stelrad product identification code. Warranty The warranty covers any defect that is attributable to a manufacturing, assembly or material fault, further details available on request. ISO14001 Is a set of International regulations related to the environment. ISO9001 Is a set of International regulations related to quality management systems. OHSAS18001 Is a set of International regulations related to health and safety. TBOE / BOE Refers to which position the pipes are connected to the radiator, OE means opposite end i.e. 1 pipe on each side, TB is top bottom i.e. 1 pipe is connected to the top and 1 to the bottom, B is both pipes connected to the bottom. CETIAT tested A leading independent French laboratory which conducts testing and assessments. EN 442 is the European standard which defines the manufacturing standards for radiators and convectors which operate at temperatures of less than 120°C. The standard defines the type of steel which must be used, the type of pressure testing which must be carried out and the accuracy of the heat outputs quoted in the literature. The Stelrad Technically Advanced Radiator System heatloss calculator, offers an even simpler way to get sizing of radiators right, first time. Visit www.starsapp.co.uk KIWA CPD BIM KIWA Ltd is an energy consultancy, Notified Body, UKAS-accredited testing lab and training centre with expertise in gas, oil, solid fuel, biomass and other renewables, construction materials, water and electricity. Continuing Professional Development. CIBSE (Chartered Institute of British Service Engineers) and RIBA (Royal Institute of British Architects) CPD approved courses available. Business Information Modelling (components). Visit www.stelrad.com to download BIM components. RAL A European wide colour matching system. BSP British Standard Piping. 149 Corporate Social Responsibility (CSR) Stelrad Limited are part of the Ideal Stelrad Group. Wherever possible, Stelrad sources renewable and The company recognises that its success is built on recyclable materials. 100% of all metal and other integrating business values and operations to meet raw materials throughout the manufacturing the expectations of stakeholders. Stelrad’s social, process are recycled. economic and environmental responsibilities are to these stakeholders, which are demonstrated throughout A full CSR policy document is available on request. its business practises, policies and achievements. Stelrad are committed to Integrated Management Systems for control of Quality, Health and Safety and Environment, which are certificated to BSI OHSAS / ISO standards. ISO 14001 ISO 9001 OHSAS 18001 Environmental Management Quality Management Occupational Heath and Safety Management IPPC INTEGRATED POLLUTION PREVENTIONCONTROL Design service We offer developers and specifiers a comprehensive heating system design service. Please contact us on 0191 261 5106. Heat outputs stated at 30°C and 40°C are based on a standard n-coefficient of 1.3. Whilst every effort is made to provide accurate information, we reserve the right to change specifications and availability without prior notice. 150 There’s so much more to Stelrad Elite: Page 6 Compact Range: Page 7-9 STR: Page 10 Towel Rail Range: Page 11 Caliente Towel Rail Range: Page 12-13 Concord Towel Rail: Page 14 Esprit: Page 15 Softline: Page 16 Compact with Style Range: Page 18-19 151 There’s so much more to Stelrad 152 Planar Range: Page 20-21 Concord Range: Page 22-23 Classic Column Range: Page 24-25 Swing: Page 26 Caliente: Page 27 Excel: Page 28 Arc: Page 29 Wave: Page 29 Vistaline: Page 30 Ellipse: Page 31 Optia: Page 32 Radical: Page 34 LST Standard: Page 36 LST Plus Vertical: Page 37 LST Plus: Page 38 LST i Plus: Page 39 153 We have it covered 2 year warranty on all commercial condensing boilers EVOMAX IMAX XTRA EVOMOD 30 - 150 kW 80 - 560 kW 250 - 1000 kW - Wall hung - Robust and light aluminium silicon alloy heat exchanger - Up to 110% part load efficiency - High 5:1 turndown - Low NOx emissions <40mg/kWh for all natural gas models - Quality product through design, component selection and proving - LPG models 30 - 80 kW - Built in hours run and frost protection - Simple controls interface with large backlit display - Optional frame and header kits - Compact for easy installation - Remote indication and 0-10 volt operation standard - ECA listed - Floor standing - Robust and light aluminium silicon alloy heat exchanger - In-built commissioning and fault diagnostics - Low NOx emissions <40mg/kWh - Compact size – small footprint - High 5:1 turndown - Up to 107.5% net efficiency (fully condensing) - Fits through standard doorways - Remote indication and 0-10 volt operation standard - ECA listed - Floor standing - Stainless steel heat exchanger - Modular boiler benefits: - Heat maintained during service - Easier installation as lighter, smaller parts - High modulation & close load matching (5:1 up to 20:1) - Low NOx emissions (<40mg/kWh) - Module sequencing as standard - Single flue, system gas & electrical connections - Quality product through design, component selection and proving - Compact & minimum floor area - Assembled & site assembly capability - Remote indication and 0-10 volt operation standard - ECA listed For more information contact Ideal Commercial Heating: T: 01482 492251 E: enquiries@idealheating.com WWW.IDEALCOMMERCIALHEATING.COM 154 Follow us on: @stelradradiator facebook.com/stelradradiators pinterest.com/stelrad Stelrad Limited Stelrad House Marriott Road Mexborough South Yorkshire S64 8BN www.stelrad.com Telephone: 0844 543 6200 TRB/10K/0614 156
Similar documents
Stelrad Radiator Specification
Our aim is to help you to deliver superior environmental solutions that optimise building performance. We do this by providing you with a package of tools, support, products, manufacturing and inno...
More informationLST Range
LST i Plus wall fixings and bracket positions All dimensions in mm. Inches in brackets.
More informationLow Surface Temperature Collection
After installation of a new Stelrad radiator the central heating system should be cleaned and flushed with cleaner to remove existing contaminants, flux residue and other installation debris which,...
More information