Yonos PARA NFSL 12/6 RKC Datasheet
Transcription
Yonos PARA NFSL 12/6 RKC Datasheet
Pioneering for You HVAC OEM Competence Centre Yonos PARA NFSL 12/6 RKC Datasheet Datasheet Yonos PARA NFSL 12/6 RKC Yonos PARA NFSL 12/6 RKC Field of application Heating Yonos PARA NFSL 12/6 RKC 12 Yonos PARA NFSL 12 6 RKC 12 High Efficiency pump for heating application Composite OEM pump housing Threaded connection DN 12 6 = delivery head in [m] at Q = 0 m3/h The pump is controlled by Red Knob technology RKC = P-v, constant speed I, II, III Control box orientation 12 o’clock (3, 6, 9 o’clock: also available) 02/08 Datasheet Yonos PARA NFSL 12/6 RKC Hydraulic operational area Δp-v (variable) 03/08 Datasheet Yonos PARA NFSL 12/6 RKC Hydraulic operational area Constant speed I, II, III 04/08 Datasheet Yonos PARA NFSL 12/6 RKC Electrical connections Integrated Molex 3-way connector Overmoulded connector Overmoulded power cables Molex connector Volex connector WS8 connector 05/08 Datasheet Yonos PARA NFSL 12/6 RKC Dimensions 06/08 07/08 Datasheet Yonos PARA NFSL 12/6 RKC Approved fluids (other fluids on request) Heating water (in accordance with VDI 2035) Water-glycol mixtures (max. 1:1; above 20% admixture, the pumping data must be checked) Power Energy Efficiency Index (EEI) ≤ 0,20 Max. delivery head 6.6 m Max. volume flow 2.4 m3/h Permitted field of application Temperature range for applications in HVAC systems at max. ambient temperature. Limit values for continuous operation at maximum rated power Of 58°C = 0 to 100°C Of 62°C = 0 to 90°C Of 66°C = 0 to 80°C Of 71°C = 0 to 70°C Maximum static pressure PN 6 Electrical connection Mains connection 1~230 V +10%/-15%, 50/60 Hz (IEC 60038 standard voltage) Motor/electronics Low voltage directive 2006/95/EC Conform Electromagnetic compatibility EN 61800-3 Emitted interference EN 61000-6-3 EN 61000-6-4 Interference resistance EN 61000-6-2 EN 61000-6-1 Protection class IPx4D Insulation class F RoHS / REACH Not submitted Minimum suction head at suction port to avoid cavitation at water pumping temperature Minimum suction head at 50/95°C 0.5/4.5 m Motor data Yonos PARA NFSL 12/6 RKC Speed Power consumption 1-230 V Current at 1-230 V Motor protection n P1 I - rpm W A - 800 - 4300 3-45 0.03-0.44 Integrated Materials Yonos PARA Pump housing Impeller Pump shaft NFSL 12/6 RKC PA6.6 composite with GF 30% PP composite with GF 40% Stainless steel This document is subject to change without prior notice 04/2015 WILO SE Bearing Carbon, metal impregnated WILO HVAC OEM Competence Centre 50 av. Casella 18700 - Aubigny sur Nère France T +33 2 48 81 62 62 information@wilointec.com www.wilointec.com Pioneering for You
Similar documents
Yonos PARA NFSL 12/7.0 PWM1 Datasheet
Of 58°C = 0 to 100°C Of 62°C = 0 to 90°C Of 66°C = 0 to 80°C Of 71°C = 0 to 70°C
More information