Hybrid MW EES_UPS Solution _INCELL
Transcription
Hybrid MW EES_UPS Solution _INCELL
Large Hybrid(MW) EES (UPS Emergency (UPS, E Electric El t i Power P , Demand D dM Management) t) INCELL Co., Ltd Overview Introduction Large Hybrid EES System feature Large Hybrid EES System composition product Introduction 1.SAVEEN MG – UPS & Demand Management UPS System accident Vital load voltage General load voltage Demand D d Management (DM) Peak Shift/Peak Cutting Discharge - R h Recharge Introduction 2.SAVEEN MG – Configuration Kepco system General load EMS Vital Load Introduction 3.SAVEEN MG vs Previous UPS Series double-transformation structure (Previous UPS) Strength Guarantee the quality of power on various power supply problems Drawba ck - Low efficiency / Price increase Parallel single-transformation structure (SAVEEN) Strength Drawback •High efficiency / Meet to demand management - Unable to control the out put voltage and frequency. Large Hybrid EES System feature: Emergency Electric Power &Demand Management 1. A. Off-Line UPS Use high- speed switch to guarantee UPS - The feature of UPS(< 4msec ) : It is able to use for IDC and Data processing room - Option i operation: i Reduce d the h unnecessary power loss( l ( 10% reduction) d i ) andd prevent the life- shortening ( Two times lifespan) Normal condition Black out condition B. The function of Large and high output on Hybrid EES System : available uninterruptable g and emergency g y ggenerator function of large - It covers the specific supply range for large and emergency power supply and enlarge the time; UPS cannot guarantee them. - Supply S l non-interrupting i t ti electric l t i source until til operating ti the th emergency generator: t Bulk B lk andd high-speed, a large output Large Hybrid EES System feature: Emergency Electric Power &Demand Management C. The effect on replacement of previous UPS 1) Off Line UPS - Optional operate: No power loss in general ( which included in high-efficiency energy products) - UPS is required the heavy power consumption which operates power rectifier for 24hrs 2) U Use lithi lithium battery b tt : selective l ti capacity it & easy maintenance, i t l long lifespan, lif flexible area of installation - Offer various capacities selection: From 5 minutes to 1 hour or more; with based on situation - The application of BMS / Battery monitoring :actively cope with emergency situation - It is effective in the space application side which it’s volume is 30% less than the lead acid storage system - Guarantee the long -lifespan: the function of effective power management through over 5,000 times of charge and discharge. 3) Peak management available in general operation of EES System : - Advantages g of electric charges g reduction and return on investment ** 40% in installation rate of the total facilities required of UPS → With combination bi ti off EES function, f ti which hi h is i a favorable f bl position iti in i return t on investment i t t and cost of initial investment matter and others. Large Hybrid EES System feature: Emergency Electric Power &Demand Management D. The time function of emergency generator linked to ATS switchover : The enlargement of the application range on emergency electric power 1) Guarantee G t the th uninterruptible i t tibl power off emergency generator t : the th supplementation l t ti off the th initial action ability of emergency generator - Blackout and other accidents: the correspondence function of uninterruptible power in golden time which is until operating emergency generator. - It is suitable for demand management business such as use of emergency generator 2) The control of operation of diesel generator for emergency : secure the emergency power capacity over 30min; which is available for blackout - The Th specific ifi workplaces k l which hi h are sensitive i i to the h problem bl off iinstallation, ll i emissions i i andd noise. i 3) Use lithium battery with high output(4C~10C) - Guarantee the stability of emergency power with instant output function ** The installation size of emergency generator: 70,000 pcs in the whole country in Korea. / the th total t t l generating ti capacity it = 21GW volume l Large Hybrid EES System Composition 1. PCS product family for Large Hybrid EES System A. PCS(which guarantee of instant voltage ): STABLEEN_DVC - The guaranteed time for uninterruptible power: 3sec to 1 min. - Storing device: Super Capacity ~ use high-output with high power Lithium battery. - Main used place: semi-conductor production line, oil refining, fine chemistry and others which are required to cope with instant blackout. B. Off Line UPS + DM Hybrid PCS : SAVEEN_MG - The guaranteed time for interruptible power : 6 / 15 / 30 / 60mins or over, - Storing g device : high-output( g p ( 1C ~ 10C ) with high g ppower Lithium battery y use. - The guarantee way of uninterruptible power : Static Switch (reaction velocity : < 4mS ) - Main service place : the place which include both UPS and emergency generator, the hospital, CCTV control center, IDC, base station, telephone company and other communication facilities. Additionally, y, Micro grid, g , power p plant p and power transmission. C. PCS which is possible to drive independently for blackout : SAVEEN_ES - Use of Dynamic Switch, independent drive for recovery from black out within only 3 sec. In general, which is available to use of DM as well as emergency situation, - Service place : ordinary factory, water supply , buildings and others which require electricity. Large Hybrid EES System Composition 1-1. Off Line UPS + the function DM Hybrid PCS SAVEEN200 (MG-LV) SAVEEN250 (MG-LV) 200kVA 250kVA 570~830V 570~830V 356A 482A 97% (rate voltage,100% load) 97% (rate voltage,100% load) 60Hz 60Hz AC 380V / ± 10% AC 380V / ± 10% AC (Power factor) 08 0.8 08 0.8 AC constant value 3상4선 3상4선 Switchover time < 4 msec < 4 msec AC voltage THD < 3% < 3% AC current THD < 3% < 3% The form (H X W X D)mm 1800 X 2500 X 800 1800 X 2500 X 800 Capacity DC driving voltage range/rate voltage DC maximum current Power-conversion efficiency AC frequency AC rate voltage / tolerance band Large Hybrid EES System Composition 2. LiB Storage System for emergency power EES with high output ※ Standard Module Standard Rack EESS & UPS( Energy Storage System) ※ CE Safety & Reliability Approval Large Hybrid EES System Composition 2.1 Lithium battery system Line Up ( Emergency power Hybrid EES ) Specification(10~15mins. guaranteed) Item Max. Output Power(PCS) 200kVA 250kVA 500kVA Nominal Capacity 33kWh+ 49.7kWh+ 82.9kWh+ Nominal Voltage g DC 691.2V DC 691.2V DC 691.2V Operation Voltage DC 576~768V DC 576~768V DC 576~768V BESS Rack(Q’ty) 2EA 3EA 5EA DC Max Current(A)/Rack 200 200 200 Weight(approximate)(kg) 750(kg) 1,125(kg) 1,875(kg) Dimension(WxDxH)mm 1200 X 760 X 2000 1800 X 760 X 2000 3000 X 760 X 2000 Large Hybrid EES System Composition 2-2. The advantages of lithium battery application 1) The advantages application: energy density, life Cycle, self-discharge rate, temperature and others LiB Module The upper side LiB spec. 3.6V Nominal voltage 2V 150~180 Energy density (Wh/Kg) 30~50 윗면 front side > 3,000 LiB system 15Y~20Y -20~40degree Cell Sub BMS Module Rack System Standard Module 19” Rack Lead acid spec. classification Y <10%/year No need N Cycle life ( 200~300 80% of the initial capacity) Calendar life Operation temperature BMS general : 3~5Y no repair : 5~10Y 0~ 25degree N Self-discharge rate (25℃) 35%/year Inspection check Necessary Environment harmful substance Lead, Sulfuric acid Large Hybrid EES System Composition 2-3. EES UPS construction comparison UPS system requirement: 500kVA, nominal voltage 384V, backup time 30mins. Battery Lead Acid LiB(INCELL) Battery system spec. 384V 1000Ah (cell : 2V 500Ah / composition i i 192S2P) 388.8V 704Ah (module : 43.2V 88Ah / composition i i 108S40P) voltage/capacity /weight 2V / 500Ah / 34kg 43.2V / 88Ah / 38kg Cell Q’ty 384EA 72EA Cell size 173x 251 x 387 mm 440 x 635 x 88 mm System weight (Rack excluded) 13 056 kg 13,056 2 856 kg 2,856 System volume 43,248 ℓ 7,551 ℓ The decrease of load restriction of building : 13,056kg Effective space application : Real time monitoring: monitoring: Battery composition 2070 4000 5100 760 4800 2,856kg 82.5% 43,248 ℓ 2120 78% 7,551ℓ Thank you! y sales@incell.kr