Case Study: Hoyts Charlestown, VIC
Transcription
Case Study: Hoyts Charlestown, VIC
Case Study: Hoyts Charlestown, VIC www.airmaster.com.au CASE STUDY Energy Management 01 Project Summary Hoyts are one of the major cinema chains located throughout Australia. The complex in Charlestown has 6 cinemas. Each served by a large DX Packaged Air Conditioning Unit and some additional units that serve the foyer and ancillary areas. The site had an ageing Building Management System (BMS) installed. The BMS had a Graphical User Interface (GUI) installed allowing excessive operator control, resulting in manipulation of plant operation. This resulted in air-conditioning running for extended periods, inappropriate temperature settings and in-efficient operation due to operator intervention. Critical failure of the main GUI then led to no vision of plant operation whatsoever. The main priority for the client was to restore plant control and obtain a simple easy to use interface, so that the on-site staff can efficiently manage the air conditioning and that senior management could also manage and monitor remotely. kWh -22% 02 The Solution Airmaster Australia (The incumbent mechanical maintenance contractor) offered the Ecobee EMS as the solution. The Ecobee (IDT) Devices were installed in the BioBox so that the projector staff could change occupied/temperature settings according to the movie running schedules and respond to customer complaints/feedback. Significant energy savings were observed almost immediately as the local staff were able to more effectively manage the air conditioning. The Ecobees also provided improved temperature control and assisted with diagnosing any mechanical faults. Four Points Sheraton CASE STUDY Energy Management 03 Project Outcomes Since the Ecobee devices were installed in March 2011, an instant reduction in energy use was apparent. We continued to monitor these values for 6 months in order to produce the graph shown below. After 6 months, it was obvious that the thermostat control had impacted the operation of the climate control significantly with an average energy reduction of 22%. 90k The energy consumption trend has continued to retain an average of 22% each month 80k 70k -20% 60k 50k -33% -30% -22% -11% -20% 40k 30k 20k 10k kWh 2010 kWh 2011 The graph above shows a monthly comparison between 2010 and 2011. The Ecobee EMS were installed and commissioned in March 2011. kWh -22% 06 Conclusions The staff at Hoyts now have full control over their airconditioning settings, allowing them to manage energy consumption without the need for technical expertise. Average Annual Energy Saving Four Points Sheraton