Case Study_SUNFOLD powers a living camp of a
Transcription
Case Study_SUNFOLD powers a living camp of a
CaseStudy Date: April18,2016 SUNFOLDpowersalivingcampofamineinRDCongo PowerRequirements Thelivingcampismadeupof18ISOcontainersandhasanestimatedavegaredailyconsumptionofca.325kWh.Theconsumptionismoderateduring thedaytimeandfairlyheavyduringthenighttime.Thedailypeakconsumptionisestimatedat24kW.Seenovertheyeartheaveragedaily consumptionisconstant. Location TypicalSUNFOLDSet-up TigerPower 1/3 18/04/16 SystemInputParamaters Location KolweziRDCongo Estimatedmaxiumumdailyconsumption Consumptionprofile kWh 325 Moderatedaytimeandheavyeveninguser Estimateddailypeakpowerconsumption kW Averageannualprofile 24 Constantconsumption SUNFOLDConfiguration NumberofSunfolds 18 TotalinstallednominalPVpeakpower kWp Inclinationofsolararrays Fixedtilt 84 0° Totalinstalledbatterycapacity@C100 kWh 389 Availableenergystoragecapacity@D.O.D.50%/C100 kWh 194 Estimatedbatterylifetime(365cyclesperyear@30°C) years 6 Option1:EachSUNFOLDsystemservesaseperatemonophaseload kW 4,5 Option2:3parralleledSUNFOLDsystemserveacommonmonophaseload kW 13,5 Option3:3x3parralleledSUNFOLDsystemsserveacommontriphaseload kW 40,5 Estimatedannualgeneratedenergy kWh 130.150 Estimatedannualconsumedenergy(onmonthlyaveragebasis) kWh 118.625 Estimatedannualenergybalance(onmonthlyaveragebasis)* kWh Estimateddailyloadthatcanbeserved(Jan-April-July-Oct) kWh Estimatedsystemautonomyataverageconsumption hrs 14 EUR/kWh 0,61 Maximumpeak powerfromthe system EnergyBalance(Productionvs.Consumption) 11.525 242 323 323 323 note*:canbeavoidedbyoptimizingtheloadprofileorcanbestoredinanadditionalbatterypack. ElectricityCost*andDieselsavings Estimatedpriceofelectricityfromdieselgenset(onlyfuelconsidered) Estimatedpriceofelectricityoverthelifetimeofthebatteries 6 years EUR/kWh 0,55 Estimatedpriceofelectricityincl.onebatteryreplacement 12 years EUR/kWh 0,32 Estimatedpriceofelectricityincl.twobatteryreplacements 18 years EUR/kWh 0,25 EUR/year 72.818 Estimatedannualfuelsavings@1,5€/ltr note*:financing,taxes,insurance,maintenance,transport,depreciationnotincluded Optionalback-upgenset* OptimalGensetrating kVA Estimateddailyrunninghours(Jan-April-July-Oct) hrs 7,5 8 0 0 0 note*:Forinformationonly.Aback-upgensetisnotstrictlynecessaryandcanbeavoidedbyoptimizingtheloadprofilee.g.bytime-regulated consumptions TigerPower 2/3 18/04/16 DailyGeneration&ConsumptionProfile Thebelowchartshowsthepredictedenergyproducedandeneryconsumedonanaveragedayduringeachmonthoftheyear 60 50 Consumption 40 Jan Power(kW) 30 April July 20 October 10 00 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 -10 0 1 2 3 4 Tmeintheday MonthlyEnergyBalance Thebelowchartshowstheenergybalanceonanaveragedayduringeachmonthoftheyear 450.0 400.0 350.0 kWh 300.0 250.0 Consumption 200.0 Production 150.0 100.0 50.0 1 2 3 4 5 6 7 8 9 10 11 12 Monthoftheyear Theabovegraphshowstheratiobetweenproducedandconsumedenergy.Eventhoughonamonthlyaveragethegraphshowsexcessenergy,itmay occurethatondailybasisthesystemcannotservetheload.e.g.Incaseofheavynightconsumers. Conclusion Thiscasestudyshowshowalivingcampofacopperminemadeof18containerscanbepoweredby18Sunfolds.Theannualfuel savingsareestimatedtoca.73.000€withoutcomprimisingonpoweravailabiity.Inordertocopewithreducedcleanenergy availabityduringwintermonths,asmallgensetof7,5kWcanbeconsidered.Thebetteralternativeistoinstalloneormoreof TigerPower'sStoragersthatprovidelongtermenergystorage. Disclaimer Thiscasestudyreportisforinformationonlyandconnotbeconsideredasbinding.Thecalculationsarebasedontheinformationmadeavailableto us.Incaseofmissingdatatypicalvaluesarepresumed.Thecalculationisperformedwithtpyicaloff-gridsystemefficienciesfordirectandindirect consumption.Theactualefficiencyofthesystemvarieswithtemperature,irradtiation,cablelengts,consumptionprofilesandotherenvironmental factors. TigerPower 3/3 18/04/16