suite - Giorgio Gervasoni
Transcription
suite - Giorgio Gervasoni
SUITE 29 SUITE RESIDENTIAL Inspiration, Innovation, Evolution INTRODUCTION TO THE RANGE OF PRODUCTS RESIDENTIAL RANGE GROUPS OF UNITS POWER RANGE SUITE RESIDENTIAL PRODUCT RANGE The Kaysun RESIDENTIAL range has gone further and now offers a wide range of units suitable for each customer. Always seeking the well-being of the user, is at the forefront of innovation, presenting a range that meets all market demands, respecting the environment and guaranteeing the comfort of the client. than 4 in SCOP for some of its models. Therefore, we not only observe the current directives on energy efficiency, but the future ones too. “ELEGANCE Kaysun units, with a balanced and harmonious aesthetic, meet the European directive “ErP” (energy related products), offering SCOP values between “A”, “A+” and “A++”. Our range of products consolidates its position in the market by offering products with a seasonal energy efficiency under heat mode that are even higher AND COMFORT FOR YOUR HOME” 3D TECHNOLOGY DC INVERTER Indoor fan motor The 3D technology is present in the majority of the 1x1 sets and in the multisystem combinations, which include wall-mounted, ducts, cassettes and double flow consoles. electricity consumption 10W DC INVERTER Outdoor fan motor DC INVERTER Compressor motor electricity consumption This advanced technology is reflected in the use of a DC Inverter motor in both the compressor and fans of the indoor and outdoor units; thus, the unit provides the user with, not only high efficiency, but significant savings. Thanks to the continuous technological development of the KAYSUN 3D DC INVERTER range, it has been possible to achieve technologically evolved equipment that, thanks to their multiple functions, adapt to and satisfy the needs required on each moment, thereby creating environments that are in constant balance -more constant temperature, a high level of savings, less noise...-in order to always provide the user with the most well-being. The DC INVERTER compressor, stands out for the evolution of its frequency, which has gone from 10 stages in standard equipment to 25 stages in current KAYSUN equipment. These changes provides a much more precise control of the power demanded, improving energy efficiency and achieving ever-greater comfort. equipment CONVENTIONAL equipment C KAYSUN equipment equipment K +* 05=,9;,9 40W % Double rotatory Less noise Less vibration Protection IPX4 Efficient ≥70% 4 6 30 7 8 9 10 5 4 25 stages energy consumption energie saving temperature control SCOP The DC Inverter motor fans of the outdoor units gain a much more precise control thanks to its 5 speeds, which reduces the (low) sound pressure, and allows for greater output and energy saving of the KAYSUN set. Likewise, the indoor unit fans now have 12 speeds, thereby adapting with precision to the demands of the area to be climate controlled, and always placing emphasis on the comfort, well-being and savings of the user. 3 energy consumption energie saving temperature control SEER The compressors used in the KAYSUN units not only are different from conventional units, but all the components of the SUITE range are fitted with features that provide the user with a high performance. 2 10 stages Simple rotatory TRIPLE DC INVERTER 11 3 5 1 2 1 12 COMBINED SYSTEMS KEY INSTALLATIONS 1W CONSUMPTION CONDENSATION CONTROL In relation to the European Directive ErP, which takes into account the different unit consumptions at partial charge and in distinct working conditions, output in Stand-by mode has been perfected, arriving at a consumption of just 1W. This represents energy savings of 80% compared with the previous generation of wall-mounted units on the market. Conventional units usually consume 5W. Wall-mounted units are equipped by default with condensation control, which allows us to work in cold mode under extreme temperatures of down to -15ºC, thus covering the demands of the areas that require cooling even in winter time. 5W 80% 1W SUITE + OUTDOOR UNIT Likewise, the operating range of the 1x1 wall-mounted and solar units in heating mode has increased. (AUREA units operating range: -20 a 30ºC). 50 ºC Outoor temp. temp. exterior -15 ºC 30 ºC Outoor temp. temp. exterior -20 ºC LEAK AUTO-DETECTION SWING-LOUVRE MEMORY The system controls the discharge temperature of the compressor. When it is out of the adequate parameters for 4 seconds within 3 consecutive times, the unit displays the alarm code “EC”. This function allows the equipment to operate correctly and the user to detect any problem easily. The unit stores the position of the louvres when it is turned off; the unit will return to that same position when it is turned on again. 1 OUTDOOR UNIT FASE PHASE 2 FASE PHASE 3 FASE PHASE INDOOR UNIT 15 º Wall-mounted KID-02 S REMOTE CONTROLLER MEMORIZA LA INCLINACIÓN TILT STORING APAGA LA UNIDAD UNIT SWITCHING OFF SE RECOLOCA EN TO LOUVRES RETURN PRIOR POSITION LA MISMA POSICIÓN NEW Introducing the new control for the KAYSUN residential range. It is standard in the AUREA range. Among the features of this new control, we would like to emphasise its capability to read the operation data of the AUREA units range, such as the room temperature, pipeline temperature, discharge temperature, the compressor's energy consumption, and so on. Besides, it allows to change the operating parameters of mentionned units, such as activating the Auto Restart function, changing the compensation temperature, programming the fan's stop and so on. All these features allow the installation engineer to adapt the unit more easily to the spaces to be climate controlled, and make the operation control of the unit easier during the service tasks. We would like also to stress that this new control is fitted with the corresponding keys to activate/deactivate the SILENCE, 8º HEATING, FOLLOW ME and AUTO-CLEANNING modes, provided that the indoor unit is compatible with it. 31 RESIDENTIAL INDOOR UNITS Inspiration, Innovation, Evolution RESIDENTIAL RANGE INTRODUCTION TO THE RANGE OF PRODUCTS GROUPS OF UNITS POWER RANGE KID-01 S REMOTE CONTROL FOLLOW-ME The standard “FOLLOW ME” function included in the wireless controllers of the SUITE range units, allows us to enjoy greater comfort thanks to an environmental sensor integrated into the wireless control. Said sensor perceives the temperature of the area where the wireless controller is located, avoiding stratification problems when the unit is regulated by the return sensor, and fixes a more precise and real set point for the customer. 23ºC 23ºC 23ºC 29ºC CLIMATE CONTROL WITH FOLLOW-ME CLIMATE CONTROL WITHOUT FOLLOW-ME 8ºC HEATING TURBO FUNCTION This option is highly useful for rooms that are unoccupied. It ensures that the temperature of the room is never less than 8ºC. When the unit detects a temperature below the minimum value established, the unit switch on immediately. The unit will start and stop repeatedly to keep temperature at 8ºC until the temperature of the room increases. The user will always have a room with a comfortable temperature in winter, even when not present. The “TURBO” function makes the compressor work at a frequency of 110 % and the fan of indoor unit uses its maximum speed so as to reach the desired temperature as quickly as possible. Under cooling mode, it will return to its previous state in 30 minutes, while in heating mode it will remain in “TURBO” mode until a new order is given. AUTO CLEANING NIGHT MODE When in cooling mode, the unit is capable of creating humid climates that remove foreign bodies from the system. When in heating mode, the unit creates a dry climate that evaporates the water accumulated in the particles being expelled thanks to the fan mode. The night mode function allows the set-point temperature to be changed in order to increase comfort while we sleep. In summer, temperature rises one degree the first hour, then another degree in the next hour; this set point temperature will be maintained during 5 hours before shutting off the unit. In winter, the Night mode operates in a reverse fashion from summer, that is to say, temperature will drop one degree each hour and this temperature will be later maintained for 5 hours. 1 FASE PHASE COOLING MODE EN FRIO FUNCIONAMIENTO KEEPS TEMPERATURE FOR 5 HOOURS MANTIENE LA TEMPERATURA 5 HORAS +1ºC 2 PHASE FASE +1ºC 3 PHASE FASE HOURS HORAS 1 2 3 4 5 6 FUNCIONAMIENTO EN CALOR HEATING MODE -1ºC 4 FASE PHASE -1ºC FUNCIONAMIENTO FAN ONLY MODE DEL VENTILADOR SOLO MANTIENE LA TEMPERATURA KEEPS TEMPERATURE FOR55HORAS HOURS 32 7 off FAN ONLY MODE DEL VENTILADOR SOLO FUNCIONAMIENTO AUREA ,97 ,97 NEW The KAYSUN residential range incorporates into its catalogue for 2015 the new AUREA unit. This new unit presents an improved aesthetic and innovative technology. ~ ~ ~ ~ ~ ~ ~ ~ ~ COMBINED SYSTEMS KEY INSTALLATIONS ,97 NEW As a novelty for 2015, KAYSUN incorporates to its residential range, the first unit with refrigerant gas R-32. All the benefits and technology of the KAYSUN products in a new unit with a different type of refrigerant. SCOP 4.0 Very quiet, just 21 Db WIFI integrated control (Optional - A K02 WIFI USB is required) Innovative aesthetic New standard multifunction controller (KID-02 S) 3D DC Inverter Double drainage outlet Extra-strong support Interactive LED display INTELIGENT R32 SUITE + OUTDOOR UNIT ~ ~ ~ ~ ~ ~ SCOP 4.0 New standard multifunction controller (KID-02 S) 3D DC Inverter Refrigerant R-32 WIFI integrated control (Optional - A K02 WIFI USB is required) Interactive LED display WIFI NEW NEW The “INTELIGENT” function is a feature that allows both the controller and the indoor unit to communicate in order to collect operation data or change the configuration parameters of the unit. The electronic part of the unit is fitted with an application that allows to control the system by means of a WIFI network. NEW MULTISYSTEM MODELS K02 WIFI USB NEW Kaysun presents 3 new outdoor units for the SUITE MULTISYSTEM range: KAM2-48 DN6, KAM2-52 DN6 and KAM3-78 DN6. These units complete the range and replace other models of the same range that have been removed from the catalogue. ~ NEW This new device is used to activate the WIFI control function in the units of the AUREA range. KC-01.2 R ~ The units of the SPIRIT range allow to connect a wallmounted wired controller KC-01.2R as an optional feature. 33 RESIDENTIAL INDOOR UNITS Inspiration, Innovation, Evolution RESIDENTIAL RANGE 34 INTRODUCTION TO THE RANGE OF PRODUCTS POWER RANGE GROUPS OF UNITS + COMBINED SYSTEMS SUITE OUTDOOR UNIT KEY INSTALLATIONS UNITS 35 RESIDENTIAL INDOOR UNITS Inspiration, Innovation, Evolution RESIDENTIAL RANGE INTRODUCTION TO THE RANGE OF PRODUCTS GROUPS OF UNITS POWER RANGE SYSTEM 1x1 3D DC INVERTER The KAYSUN 1x1 Suite family is back with newness. As always, all combinations meet the European Directive ErP and easily adapt to all the spaces to be climate controlled. The KAYSUN SUITE range keeps a balanced and harmonious appearance. As we did last year, virtually the whole range is 3D and it is consolidated in the market. With regard to our units, we are still committed with the PREMIUM 3D high range units launched last year. The SPIRIT range keeps its position in the market thanks to its great success, beautiful appearance, translucent display and optional wired controller. This year KAYSUN introduces two new ranges: In first place, the AUREA range, a set of 3D units with a renewed appearance, very low sound levels, translucent display and an optional built-in WIFI control system. In second place, the R32 range, which as the name implies, provides not only all the benefits of the KAYSUN products, but a new refrigerant gas too. Our SOLAR 3D range is a proof of our commitment with solar energy. We would like to stress that all our units meet the highest SEER and SCOP values of the market. The Kaysun Suite 1x1 range is formed by four different units that have consolidated in the market as an option to be considered, given their capability for adapting to the demanding requirements of our expert customers. MONO/MULTI COMPATIBLE Aiming for functionality and always trying to make things easier for our users, the Kaysun residential range offers the possibility of using the same indoor wall-mounted units (SPIRIT, AUREA and Stylus 3D) both in multisystem and 1x1 sets, except for the 7.1kW units since they are not connectable. 1x1 SISTEMA SYSTEM OUTDOOR UNIT UNIDAD EXTERIOR In this fashion, a multisystem installation and an individual sets installation can combine exactly the same wall-mounted units, thereby allowing at the same time that a 1x1 units installation could be arranged with multisystem units modifying only the outdoor units to satisfy the changing needs of users. INDOOR UNIT UNIDAD INTERIOR Mural Wall-mounted SILENCE Our sets units are fitted with the "SILENCE" mode. This function allows to reduce the sound level of indoor units to the minimum. When this operating mode is activated, the fan automatically selects the extra-low speed, thereby reducing the sound levels of the unit and providing a calm and relaxed environment. DISTANCES AND HEIGHT DIFFERENCES* 26 35 52 71 TOTAL LENGTH 25 25 30 50 MAXIMUM HEIGHT 10 10 20 25 *Note: These distances correspond to the AUREA range. Verify these data for each range. 36 + COMBINED SYSTEMS 2.6 POWER kW SUITE OUTDOOR UNIT KEY INSTALLATIONS 3.5 5.2 7.1 SPIRIT KAY-26 DN6 KAY-35 DN6 KAY-52 DN6 KAY-71 DN6 KAY-S 26 DN5 KAY-S 35 DN5 KAY-S 52 DN5 KAY-S 71 DN5 AUREA PREMIUM 3D KAY-26 3DN5 R32 KAY-26 DR32 KAY-35 DR32 SOLAR 3D WALL MOUNTED KAY-PV 35 DN5 distributed by SOLAR 3D CASSETTE KCI-PV 35 DN5 distributed by SOLAR 3D DUCTS KPD-PV 35 DNS distributed by 37 RESIDENTIAL INDOOR UNIT Inspiration, Innovation, Evolution RESIDENTIAL RANGE SPIRIT POWER RANGE INTRODUCTION TO THE RANGE OF PRODUCTS GROUPS OF UNITS 1x1 TECHNICAL SPECIFICATIONS MODEL SET KAY-26 DN6 KAY-35 DN6 KAY-52 DN6 KAY-71 DN6 !"#$!& ' kW 1.3/2.64/3.22 1.41/3.42/4.29 1.90/5.13/5.90 2.18/6.45/7.10 !"#$!& ' Kcal/h 1118/2270/2769 1212/2941/3689 1634/4412/5074 1875/5547/6106 kW 0.144-1.240 0.139-1.650 0.157-2.270 0.204-2.730 S))* 5.61 5.63 6.11 5.91 #+# ,, A+ A+ A++ A+ ( H# !"#$!& ' kW 1.01/2.78/3.45 0.98/3.66/9.54 1.27/5.27/6.22 1.60/7.3/8.64 H# !"#$!& ' Kcal/h 867/2391/2967 843/3148/3904 1092/4532/5350 1376/6304/7430 kW 0.175-1.230 0.177-1.620 0.191-2.220 0.293-3.090 3.81 3.83 3.80 3.82 A A A A S-. /" "#,' 4.81 4.82 5.11 4.84 H# #+# ,, A++ A++ A+++ A++ 2.15 2.33 3.90 4.87 2.58 2.37 2.45 2.35 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 H# ( S-. H# #+# ,, (warm areas) H# 012 kW -. 012 ./#" ,( V / F / Hz INDOOR UNIT KAY-26 DN6 KAY-35 DN6 KAY-52 DN6 KAY-71 DN6 A" 3/ 3 m /h 650/560/450 650/560/450 750/550/480 1100/970/800 S($ "essure* dB (A) 27 27 26 30 W$4 & H#4 & 5#4 mm 800/275/188 800/275/188 940/275/205 1045/315/235 N# /#4 Kg 7.5 7.5 9 12.5 ./#" /" mm2 From outdoor From outdoor From outdoor From outdoor ( /" mm2 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5 KAE-26 DN6 KAE-35 DN6 KAE-52 DN6 KAE-71 DN6 OUTDOOR UNIT "#,," # -($" "flow S($ "essure *#R"#" *#R"#" 4"# ! S(##" Rotary Rotary Rotary Rotary 3 m /h 1800 1800 2200 2700 dB (A) 56 56 59 60 R-410 R-410 R-410 R-410 gr 800 / 15 950 / 15 1250 / 15 1950 / 30 L6($ # $##" mm (inch) ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") ø9.52 (3/8") G, # $##" mm (inch) ø9.52 (3/8") ø9.52 (3/8") ø12.7 (1/2") ø15.9(5/8") M& #4 m 25 25 30 30 H#4 $7erence m 10 10 20 20 W$4!H#4/Depth mm 780/540/250 780/540/250 760/590/285 845/700/320 N# /#4 Kg 28 28 34.5 47 charge ** of pipes ./#" /" mm 2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 ( /" mm2 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5 * Sound pressure in “Silence” mode / **Factory pre-charge for 5 metres of installation / Additional charge for every metre added after 5 metres Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 30ºC (Heating) 38 R410A SUITE + OUTDOOR UNIT KEY INSTALLATIONS COMBINED SYSTEMS 1W GENERAL FEATURES KAYSUN residential range keeps for 2015 the SPIRIT range wallmounted units, which were already introduced last year. They display an elegant appearance and they are designed to keep extra-low sound levels. Ţ Their white translucent smart DISPLAY provides user with information on the equipment and alarm systems status. When necessary, it can be turned off any time. Ţ Possibility to block the unit for heating-only function. Ţ Compatible with wired remote controller (KC-01.2 R model recommended). Ţ Drain pipe connection from left or right can be selected. Ţ Louvres position memory. Ţ Automatic reset. Ţ Leakage detection system. Ţ SCOP 3.8, SCOP 4.8 and 5.1 in warm areas, depending on the model. Ţ Compatible with 1x1 and multisystem sets. Ţ The KID-01 S wireless controller allows to query the unit's operating data, such as sensors, compressor's frequency, alarm history records, and so on. Ţ The KI-02 S optional controller allows to change configuration parameters, such as: Auto Restart function activation/ deactivation, compensation temperature change under heating mode, fan performance under THERMO-OFF mode, and so on. + + POSSIBILITY TO BLOCK THE UNIT FOR HEATING-ONLY FUNCTION COMPATIBLE WITH KC R-01.2 WIRED CONTROLLER ,97 KID-01 S STANDARD CONTROLLERS INDIVIDUAL KC-01.2 R For further information, please see our Controllers range BMS AND SOFTWARE KC-02.1 H K01-WIFI 39 RESIDENTIAL INDOOR UNITS Inspiration, Innovation, Evolution RESIDENTIAL RANGE AUREA 1x1 INTRODUCTION TO THE RANGE OF PRODUCTS POWER RANGE GROUPS OF UNITS NEW TECHNICAL SPECIFICATIONS MODEL SET KAY-S 35 DN5 KAY-S 52 DN5 KAY- S 71 DN6 899:;<= >?@?>;BD EF;<IJO?BPQJF?TIU kW 1.40/2.78/3.18 1.61/3.51/4.11 1.95/5.27/5.75 2.31/7.03/7.33 899:;<= >?@?>;BD EF;<IJO?BPQJF?TIU Kcal/h 1204/2391/2735 1385/3019/3535 1677/4532/4945 1987/6046/6304 kW 0.867 1.095 1.540 2.700 XYYZ 6.51 6.43 7.40 6.11 899:;<= P<PO=D >:?[[ A++ A++ A++ A++ 899:;<= ;<@VB \P?B;<= >?@?>;BD EF;<IJO?BPQJF?TIU kW 1.15/3.07/3.39 1.20/3.81/4.61 1.38/5.56/6.43 1.65/7.62/8.81 \P?B;<= >?@?>;BD EF;<IJO?BPQJF?TIU Kcal/h 989/2640/2915 1032/3277/3965 1187/4782/5570 1419/6553/7577 kW 0.808 1.114 1.734 2.540 4.03 4.03 4.01 4.05 \P?B;<= P_>;P<>D >:?[[ A+ A+ A+ A+ X8]^ E`?OF ?OP?[U 5.10 5.11 5.14 4.83 A+++ A+++ A+++ A++ 2.68 3.02 3.89 4.78 3.21 2.74 2.51 2.44 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 \P?B;<= ;<@VB X8]^ \P?B;<= P<PO=D >:?[[ (warm areas) \P?B;<= >?@?>;BD abc8 kW 8]^ abc8 ^9`PO [V@@:D V / F / Hz INDOOR UNIT KAY-S 26 DN5 KAY-S 35 DN5 KAY-S 52 DN5 KAY-S 71 DN5 m;O n:9` m3/h 490/430/310 500/440/320 710/610/510 1060/860/670 X9V<Q @Oessure* dB (A) 21 21 23 24 k;QBeJ\P;=eB/Depth mm 770/295/198 850/300/198 1010/325/230 1130/340/240 lPB `P;=eB Kg 7.2 8.5 11.4 13.7 ^9`PO `;O;<= mm From outdoor From outdoor From outdoor From outdoor 89FFV<;>?B;9< `;O;<= mm2 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5 OUTDOOR UNIT KAE-S 26 DN6 KAE-S 35 DN6 KAE-S 52 DN6 KAE-S 71 DN6 89F@OP[[9O BD@P Rotary Rotary Rotary Rotary 2 ]VBQ99O ?;Oflow m3/h 1900 2000 2100 2700 X9V<Q @Oessure dB (A) 55 55 58.5 60 R-410 A R-410 A R-410 A R-410 A gr 850 / 15 1030 / 15 1650 / 15 1950 / 30 f;gV;Q @;@P Q;?FPBPO mm (inch) ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") ø9.52 (3/8") h?[ @;@P Q;?FPBPO mm (inch) ø9.52 (3/8") ø9.52 (3/8") ø12.7 (1/2") ø15.9(5/8") i?TI @;@;<= :P<=Be m 25 25 30 50 ^;@P eP;=eB Q;jerence m 10 10 20 25 k;QBeJ\P;=eB/Depth mm 810/558/310 810/558/310 810/558/310 845/700/320 lPB `P;=eB Kg 30 30.5 36 49.8 ZPdO;=PO?<B ZPdO;=PO?<B >e?O=P J XV@@:PFP<B?OD charge ** ^9`PO `;O;<= mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 89FFV<;>?B;9< `;O;<= mm (4+T)x2.5 (4+T)x2.5 (4+T)x2.5 (4+T)x2.5 * Sound pressure in “Silence” mode. 2 Working temperature range: -15ºC to 50ºC (Cooling) / -20ºC to 30ºC (Heating) **Factory pre-charge for 5 metres installations / Additional charge per added metre. 40 KAY-S 26 DN5 SUITE + OUTDOOR UNIT KEY INSTALLATIONS COMBINED SYSTEMS 50/60 Hz R410A 1W GENERAL FEATURES Introducing AUREA, the new unit for the Kaysun Suite range. This wall-mounted unit replace the former STYLUS 3D and introduces new elements. Its 3D technology and new design will undoubtedly get your attention. Ţ Possibility to block the unit for heating-only function. Ţ Drain pipe connection from left or right can be selected. Ţ Louvres position storage. Ţ MONO and MULTI units are compatible. Ţ Automatic reset. Ţ WIFI control and optional K02 WIFI USB connection for both local and remote control of the unit. Ţ Leakage detection system. Ţ Ţ INVERTER (3D) compressor and fans. Ţ The white translucent smart DISPLAY provides user with information on the equipment and alarm systems status. When necessary, it can be turned off any time. This unit also includes the MUTE mode, which consists in turning the beeper off when it is no longer necessary. KID-02 S controller included. This device is able to read the operating parameters of the unit, as well as making the corresponding configuration adjustments in order to effectively adapt the unit to the spaces to be climate controlled. Ţ SCOP 4.0, over European Directive ERP, for a high energy efficiency. SCOP 4.8 and 5.1 in warm areas, depending on the model. + + POSSIBILITY TO BLOCK THE UNIT FOR HEATING-ONLY FUNCTION CONTROLLED BY WIFI NETWORK (OPTIONAL) NEW KID-02 S STANDARD NEW OPTIONAL WIFI CONTROL K02 WIFI USB ACCESSORY ,97 CONTROLLERS For further information, please see our Controllers range BMS AND SOFTWARE K01-WIFI 41 RESIDENTIAL INDOOR UNITS Inspiration, Innovation, Evolution RESIDENTIAL RANGE PREMIUM 3D INTRODUCTION TO THE RANGE OF PRODUCTS POWER RANGE GROUPS OF UNITS 1x1 TECHNICAL SPECIFICATIONS opqrs tru KAY-26 3DN5 vwwxyz{ |}~}|y yz }} kW 1.03/2.81/3.57 vwwxyz{ |}~}|y yz }} Kcal/h 886/2417/3070 kW 0.77 vwwxyz{ yz~ 7.00 vwwxyz{ |yz| |x} A++ }yz{ |}~}|y yz }} kW 1.03/3.08/3.81 }yz{ |}~}|y yz }} Kcal/h 886/2649/3277 kW 0.78 }yz{ yz~ v 4.00 }yz{ |yz| |x} A+ v } } } 5.10 }yz{ z { |x} A++ (warm areas) }yz{ |}~}|y v 2.34 kW v v w ~~x 3.05 V / F / Hz qpp u 220-240/1/50 KAY-26 3DN5 y xw m3/h 620/480/370 wz ~ essure* dB (A) 20 y y{ ~ mm 898/298/148 y{ Kg 10 w y yz{ mm2 From outdoor vwzy|}ywz y yz{ mm2 (4+T)x2.5 puqpp u KAE-26 3DN5 vw~ w ~ Rotary ww }y flow m /h wz ~ essure dB (A) 56 ¡ y{ }z gr R-410 ¡ y{ }z |} { ~~xz} |} { ¢¢ gr 1100 / 20 3 2000 £y¤y ~y~ y} mm (inch) ø6.35 (1/4") ¥} ~y~ y} mm (inch) ø9.52 (3/8") ¦} ~y~yz{ xz{ m 25 y~ y{ y§erence m 10 y y{ ~ mm 760/590/285 y{ Kg 35 w y yz{ mm (2+T)x2.5 vwzy|}ywz y yz{ mm (4+T)x2.5 2 2 * Sound pressure in “Silence” mode / **Factory pre-charge for 5 metres installation / Additional charge for every metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 30ºC (Heating) 42 50/ 15 SUITE + OUTDOOR UNIT KEY INSTALLATIONS COMBINED SYSTEMS 50/60 Hz R410A 1W GENERAL FEATURES In 2015, Kaysun will keep PREMIUM 3D, its high range unit. This unit stands out among the rest for its metallic and avant-garde design and its innovative opening. Ţ It includes the KID-01 S controller. Ţ The EYE-DETECTOR allows for the unit to turn on/off thanks to an infrared sensor that will detect movement when somebody enters the room. Ţ The most outstanding features of this unit are the automatic reset and a leakage detection system. Ţ SCOP 4.0, over European Directive ERP, for a high energy efficiency. SCOP 5.1 in warm areas. Ţ Possibility to block the unit for heating-only function. + POSSIBILITY TO BLOCK THE UNIT FOR HEATING-ONLY FUNCTION + EYE-DETECTOR FUNCTION INCLUDED KID-01 S STANDARD ,97 CONTROLLERS INDIVIDUAL KID-01 S For further information, please see our Controllers range BMS AND SOFTWARE K01-WIFI 43 RESIDENTIAL INDOOR UNITS Inspiration, Innovation, Evolution RESIDENTIAL RANGE R-32 INTRODUCTION TO THE RANGE OF PRODUCTS POWER RANGE GROUPS OF UNITS NEW TECHNICAL SPECIFICATIONS ¨©ª«¬ «® KAY-26 DR32 KAY-35 DR32 ¯°°±²³´ µ¶·¶µ²¸¹ º»²³¼½¾¶¸¿À½»¶Á¼Â kW 1.15/2.63/3.05 1.21/3.51/4.55 ¯°°±²³´ µ¶·¶µ²¸¹ º»²³¼½¾¶¸¿À½»¶Á¼Â Kcal/h 989/2262/2623 1040/3019/3913 kW 0.860 1.080 ÄÅÅÆ 7.03 7.05 ¯°°±²³´ ¿Çµ²¿³µ¹ µ±¶ÈÈ A++ A++ ¯°°±²³´ ²³·Ã¸ É¿¶¸²³´ µ¶·¶µ²¸¹ º»²³¼½¾¶¸¿À½»¶Á¼Â kW 1.22/2.93/3.26 1.18/3.81/4.71 É¿¶¸²³´ µ¶·¶µ²¸¹ º»²³¼½¾¶¸¿À½»¶Á¼Â Kcal/h 1049/2520/2804 1015/3277/4051 kW 0.780 1.025 4.03 4.08 É¿¶¸²³´ ¿Çµ²¿³µ¹ µ±¶ÈÈ A+ A+ įÊË ºÌ¶¾» ¶¾¿¶È 5.11 5.15 A+++ A+++ 2.68 3.02 3.21 2.74 220-240/1/50 220-240/1/50 É¿¶¸²³´ ²³·Ã¸ įÊË É¿¶¸²³´ ¿³¿¾´¹ µ±¶ÈÈ (warm areas) É¿¶¸²³´ µ¶·¶µ²¸¹ ÍÎϯ kW ¯ÊË ÍÎϯ Ë°Ì¿¾ È÷·±¹ V / F / Hz ÐѪ©©Ò ÓÑЮ KAY-26 DR32 KAY-35 DR32 Ô²¾ Õ±°Ì 3 m /h 495/420/320 525/480/335 İóÀ ·¾essure* dB (A) 22 22 Ö²À¸× Á É¿²´×¸ Á Ø¿·¸× mm 722/290/187 802/297/189 Ù¿¸ Ì¿²´×¸ Kg 7.2 8.1 Ë°Ì¿¾ ̲¾²³´ mm2 From outdoor From outdoor ¯°»»Ã³²µ¶¸²°³ ̲¾²³´ mm2 (4+T)x2.5 (4+T)x2.5 ©Ó®ª©©Ò ÓÑЮ KAY-26 DR32 KAY-35 DR32 ¯°»·¾¿ÈÈ°¾ ¸¹·¿ Rotary Rotary 1800 2000 ÊøÀ°°¾ ¶²¾flow m /h İóÀ ·¾essure dB (A) 3 Æ¿Ú¾²´¿¾¶³¸ 53 54 R-32 R-32 Û²ÜòÀ ·²·¿ À²¶»¿¸¿¾ mm (inch) ø6.35 (1/4") ø6.35 (1/4") Ý¶È ·²·¿ À²¶»¿¸¿¾ mm (inch) ø9.52 (3/8") ø9.52 (3/8") Þ¶Á¼ ·²·²³´ ±¿³´¸× m 25 25 ˲·¿ ׿²´×¸ À²ßerence m 10 10 Ö²À¸× Á É¿²´×¸ Á Ø¿·¸× mm 770/555/300 770/555/300 Ù¿¸ Ì¿²´×¸ Kg 30 30 Ë°Ì¿¾ ̲¾²³´ mm2 (2+T)x2.5 (2+T)x2.5 ¯°»»Ã³²µ¶¸²°³ ̲¾²³´ mm2 (4+T)x2.5 (4+T)x2.5 * Sound pressure in “Silence” mode. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 30ºC (Heating) 44 COMBINED SYSTEMS SUITE + OUTDOOR UNIT KEY INSTALLATIONS 50/60 ¢* Hz ¢* ! 1W GENERAL FEATURES This year KAYSUN launches its first unit charged with R-32 refrigerant gas, as the range name suggests. With this new range, Kaysun shows its ability to adapt to a fast-changing market. Ţ WIFI control and optional K02 WIFI USB connection for both local and remote control of the unit. Ţ INVERTER (3D) compressor and fans. Ţ The white translucent smart DISPLAY provides user with information on the equipment and alarm systems status. When necessary, it can be turned off any time. Ţ Possibility to block the unit for heating-only function. Ţ SCOP 4.0, over European Directive ERP, for a high energy efficiency. Ţ SCOP 5.1 in warm areas with the corresponding A+++ energy efficiency label affixed. Ţ Louvres position storage. Ţ Leakage detection system. Ţ Possibility to activate automatic restart in the event of a power supply failure. Ţ KID-02 S controller included. This device is able to read the operating parameters of the unit, as well as making the corresponding configuration adjustments in order to effectively adapt the unit to the spaces to be climate controlled. Ţ Possibility to block the unit for heating-only function. + CONTROLLED BY WIFI NETWORK NEW NEW OPTIONAL WIFI CONTROL K02 WIFI USB ACCESSORY ,97 KID-02 S STANDARD CONTROLLERS BMS AND SOFTWARE For further information, please see our Controllers range ACCESSORIES NEW K01-WIFI K02 WIFI USB 45 RESIDENTIAL INDOOR UNITS Inspiration, Innovation, Evolution distributed by RESIDENTIAL RANGE INTRODUCTION TO THE RANGE OF PRODUCTS POWER RANGE GROUPS OF UNITS SOLAR ENERGY Green energy, energy savings, conservation of the environment and resource use, are some of the maxims that can be used to present our most revolutionary product, the Suit Solar 3D set. The air conditioning can function using solar energy captured during the day, even in moments when sun is hardly present, or even at night thanks to the optional battery. This direct expansion air conditioning set is at the forefront of innovation, displaying modifications that make it continue to be one step ahead. Specially designed to function by making use of solar energy, now we cannot just take advantage of this energy, we can store it. Energy savings shoot up when the battery stores the energy captured by the photovoltaic panel, which increasingly avoids the use of grid electricity by the unit to air-condition the room according to the final user demands. The appearance of the STYLUS 3D indoor unit is the same used in the design of the SOLAR 3D wall-mounted indoor unit, therefore offering an aesthetically plain unit that is suitable for any environment. In addition to taking advantage of this renewable energy, the wall-mounted set provides 6.80 and 4.00 SEER and SCOP values, respectively, which means that it has a "A++" class in Cooling mode and a "A+" class in Heating mode, therefore offering very high energy efficiency values. electric grid SOLAR 3D DUCTS HOW CAN ENERGY BE STORED? electric grid SOLAR 3D CASSETTE HOW DOES IT WORK ? electric grid 1 PHOTOVOLTAIC PANEL Parallel connection SOLAR 3D WALL-MOUNTED Selection of 6 COMPATIBLE INDOOR UNIT 30-40V DC 310V DC 4 46 BATTERY Storaged energy (optional) Converts solar energy 200-360 VCC 5 24V DC 3 CONVERSOR (Located in outdoor unit) 2 OUTDOOR UNIT CHARGE CONTROLLER Storaged energy management (optional) Optional system (2 et 3) Basic system (1, 4, 5 et 6) SUITE + OUTDOOR UNIT KEY INSTALLATIONS COMBINED SYSTEMS GREEN ENERGY “High efficiency enhancement by using solar panels, an EER higher than 32.42 % and an SEER higher than 45 %” Solar panel available up to 250 W * Based in the new EU energy Directive. EER SEER ñìñî ïìðñ ëìíî 4.86 3.78 3.67 distributed by SYSTÈMES SYSTEMS DC DCInverter inverter 3D 3DDC DCInverter Inverter 3D DC Inverter 3D DC Inverter avec panneaux solaires with solar panels ENERGY SAVING By using more solar panels, more energy is produced. “An energy saving of 47.25 % is achieved by using a 3D Inverter system with 3 solar panels ” * Calculation based on an On/Off system. energy (kW) / day àáâ energy (kW) / month energy (kW) / year ãäà € åæã åçä äèé 273 216 192 168 9.1 æêé 6.4 144 åêã SYSTÈMES SYSTEMS ON / OFF ON / OFF DC Inverter DC inverter 3DDC DC Inverter 3D Inverter avec solaire with1 panneau 1 solar panel 3D 3DDCDCInverter Inverter avec 2 panneaux with 2 solar solaires panels äêà 3D Inverter 3DDCDC Inverter avec 3 panneaux with 3 solarsolaires panels Trustworthy tests carried out in laboratory conditions 8 hours a day, 30 days a month and 3 months a year. Information is based on normal working conditions in a certain laboratory, while in actual use there may exist factors that vary slightly, such as sunlight, temperature and weather. 47 RESIDENTIAL INDOOR UNITS Inspiration, Innovation, Evolution RESIDENTIAL RANGE distributed by SOLAR 3D INTRODUCTION TO THE RANGE OF PRODUCTS POWER RANGE GROUPS OF UNITS 1x1 TECHNICAL SPECIFICATIONS MODEL SET KAY-PV 35 DN5 KCI-PV 35 DN5 KPD-PV 35 DNS òóóôõö÷ øùúùøõûü ýþõöÿC ùûCþùÿ kW 1.80/3.66/4.78 1.50/3.66/4.78 1.50/3.66/4.78 òóóôõö÷ øùúùøõûü ýþõöÿC ùûCþùÿ Kcal/h 1290/3150/4111 1290/3150/4111 1290/3150/4111 kW 1.03 1.09 1.10 S 6.80 6.10 5.60 òóóôõö÷ ö ÷ü øôù A++ A+ A+ òóóôõö÷ õöúû ùûõö÷ øùúùøõûü ýþõöÿC ùûCþùÿ kW 1.08/3.81/5.03 1.08/3.81/5.03 1.08/3.81/5.03 ùûõö÷ øùúùøõûü ýþõöÿC ùûCþùÿ Kcal/h 928/3276/4326 928/3276/4326 928/3276/4326 kW 0.87 0.95 0.97 4.02 3.82 3.81 A+ A A 5.13 5.11 5.14 A++ A++ A++ 2.78 2.78 2.78 2.91 2.91 2.91 220-240/1/50 220-240/1/50 220-240/1/50 KAY-PV 35 DN5 KCI-PV 35 DN5 KPD-PV 35 DNS 650/535/450 850 800 H H ùûõö÷ õöúû H ò S ùûõö÷ øõöøü øôù H ò ý ù þ ù ù S ùûõö÷ ö ÷ü øôù H (warm areas) ùûõö÷ øùúùøõûü ò H kW ò ò ó úúôü V / F / Hz INDOOR UNIT õ ôó m /h 3 A ó ö ú essure* dB (A) 24 39 34 mm 835/280/198 570/260/570 700/210/635 Kg 8.7 18 20 ùöô õþöõóö ýõûCõ÷ûCúû mm - 715/123/715 - ùöô öû õ÷û Kg - 2.5 - (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5 KAE-PV 35 DN5 KAE-PV 35 DN5 KAE-PV 35 DN5 S õ û õ÷û/Depth W CH û õ÷û N õ õö÷ mm 2 ó òóþþöõøùûõóö õ õö÷ mm 2 OUTDOOR UNIT òóþú ó ûüú ûóó ùõ flow Sóö ú essure R õ÷ ùöû R õ÷ ùöû øù ÷ C Double rotary Double rotary Double rotary m3/h 2000 2000 2000 dB (A) 58 58 58 R-410A R-410A R-410A gr 1300 / 20 1300 / 20 1300 / 20 õ õ úõú õùþû mm (inch) ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") ù úõú õùþû mm (inch) ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ù ÿ úõúõö÷ ôö÷û m 25 25 25 õú õ÷û õPerence m 10 10 10 mm 810/558/310 810/558/310 810/558/310 Additional charge ** L G M õ û õ÷û/Depth W CH û õ÷û Kg 38 38 38 õ õö÷ mm2 From indoor unit From indoor unit From indoor unit òóþþöõøùûõóö õ õö÷ mm2 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5 N ó * Sound pressure in “Silence” mode. **Factory pre-charge for 5 metres installations / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 30ºC (Heating) 48 SUITE + OUTDOOR UNIT KEY INSTALLATIONS COMBINED SYSTEMS 50/60 Hz ¢* R410A 5 ¢* 1W GENERAL FEATURES This year, the Suite range keeps its SOLAR 3D models. These sets are able to use solar energy to air-condition any room by means of photovoltaic solar panels, thereby obtaining a significant energy saving. Ţ Management and accumulation of solar energy with optional charge control and battery. Ţ SEER 6.80 and SCOP 4.00 for the wall-mounted unit, which means a A++ class for Cooling mode and a A+ class for Heating mode. Ţ SCOP 5.1 in warm areas. Ţ Wall-mounted white translucent smart DISPLAY provide user with information on the equipment and alarm systems status. When necessary, it can be turned off any time. Ţ Compatible with wired controller (KC-01.2 R model recommended) Ţ Possibility to block the unit for heating-only function. distributed by distributed by distributed by SOLAR 3D WALL-MOUNTED ,97 SOLAR 3D DUCTS SOLAR 3D CASSETTE ,97 KID-01 S STANDARD ,97 KI-ECO STANDARD CONTROLLERS INDIVIDUAL KC-01.2 R KC-02.1 H ,97 ,97 KI-ECO STANDARD For further information, please see our Controllers range BMS AND SOFTWARE ACCESSORIES K01-WIFI Load control 49 RESIDENTIAL INDOOR UNITS Inspiration, Innovation, Evolution INTRODUCTION TO THE RANGE OF PRODUCTS RESIDENTIAL RANGE GROUPS OF UNITS POWER RANGE MULTISYSTEM TRIPLE DC INVERTER Introducing the Suite Multisystem DC Inverter 2015 range of KAYSUN designed to provide comfort and technology to every space. The flexibility and versatility of all its indoor units, allows for multiple combinations with different types of indoor units. This range is also affected by the European Directive ERP regarding equipments of less than 12 kW, which successfully meets it thanks to its components. Such a compliance is possible thanks to the fact that KAYSUN outdoor units are always fitted with a DC Inverter compressor and fan, and almost all our indoor units are equipped as standard with a DC Inverter fan too. We confirm that almost all the combinations of this range benefit from 3D technology. These units are the solution for small spaces in which a larger scale installation is not possible. They allow for combinations containing up to 5 indoor units. There is a wide variety of indoor units available: Wall-mounted (SPIRIT and AUREA models), Cassettte ArtFlux 360º (600x600), Duct and double flow Console, with power ranging from 2 to 5.2 kW. DISTANCES AND HEIGHT DIFFERENCES* TOTAL LENGTH 2X1 3X1 4X1 5X1 30 45 60 75 30 30 MAXIMUM HEIGHT 15 MAX. INDIVIDUAL LENGTH 20 25 AUREA MODEL COMPATIBLE WITH MULTI MODEL NEW The new Suite 1x1, AUREA unit is also available for the MULTISYSTEM option, thereby replacing the former STYLUS 3D. The unit can be controlled by a WIFI network by means of the corresponding optional controller. MONO/MULTI COMPATIBLE Aiming for functionality and always trying to make things easier for our users, the KAYSUN residential range offers the possibility of using the same indoor wall-mounted units (SPIRIT and AUREA) both in multisystem and 1x1 sets. 1x1 MULTISISTEMA MULTISYSTEM SISTEMA SYSTEM UNIDAD EXTERIOR OUTDOOR UNIT In this fashion, a multisystem installation and an individual sets installation can combine exactly the same wall-mounted units aesthetically, whilst allowing for a 1x1 units installationto be arranged with multisystem units, just by modifying the outdoor units, in order to satisfy the changing needs of users. UNIDAD INTERIOR INDOOR UNIT UNIDAD EXTERIOR UNIDADES INTERIORES INDOOR UNITS OUTDOOR UNIT Mural Wall-mounted Wall-mounted Mural 50 Wall-mounted Mural Wall-mounted Mural KEY INSTALLATIONS COMBINED SYSTEMS POWER KW SUITE + OUTDOOR UNIT 2.0 2.6 3.5 5.2 INDOOR UNITS SPIRIT KAY-20 DMN6 AUREA KAY-26 DN6 KAY-35 DN6 KAY-52 DN6 KAY-S 26 DN6 KAY-S 35 DN6 KAY-S 52 DN6 KSD-26 DMN6 KSD-35 DN6 KSD-52 DMN6 NEW DOUBLE FLOW CONSOLE CASSETTE ART FLUX 360º (600x600) NEW KCI-26 DMN7 KCI-35 DN9 KCI-52 DMN7 KPD-26 DMN6 KPD-35 DN9 KPD-52 DMN6 DUCTS KPD-20 DMN6 OUTDOOR UNIT NEW POWER KW NEW 4.8 5.2 KAM2-48 DN6 KAM2-52 DN6 NEW 6.2 7.8 8.0 10.5 12.0 No OF INDOOR UNITS 2 3 4 5 KAM3-62 DN5 KAM3-78 DN6 KAM4-80 DN5 KAM4-105 DN5 KAM5-105-105 DN5 KAM5-120 DN5 51 RESIDENTIAL INDOOR UNIT Inspiration, Innovation, Evolution RESIDENTIAL RANGE SPIRIT INTRODUCTION TO THE RANGE OF PRODUCTS POWER RANGE GROUPS OF UNITS MULTISYSTEM TECHNICAL SPECIFICATIONS MODEL KAY-26 DN6 KAY-35 DN6 KAY-52 DN6 ! "#$#"%& kW 2.05 2.63 3.52 5.13 ! "#$#"%& Kcal/h 1763 2262 3027 4412 '(#%! "#$#"%& kW 2.34 2.93 3.66 5.27 '(#%! "#$#"%& Kcal/h 2012 2520 3148 4532 V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 m³/h 620/540/440 650/560/450 650/560/450 750/550/480 dB (A) 27 27 27 26 23-1 $$( 1#4(%(+ mm (inch) ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") 5#, $$( 1#4(%(+ mm (inch) ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø12.7 (1/2") mm 800/275/188 800/275/188 800/275/188 940/275/205 Kg 7.3 7.5 7.5 9 From outdoor From outdoor From outdoor From outdoor (3+T)x2.5 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5 )*(+ ,-$$& .+ /* 0-1 $+ essure* 61%78'(!7% /Depth 9(% *(!7% )*(+ *+! mm 44-"#% *+! mm2 * Sound pressure in “Silence” mode. 52 KAY-20 DMN6 2 + SUITE OUTDOOR UNIT KEY INSTALLATIONS COMBINED SYSTEMS R410A COMPATIBLE WITH GENERAL FEATURES This year, the MULTISYSTEM range keeps on offering the wall-mounted SPIRIT unit, which was introduced last year. This unit has an elegant appearance and is designed to keep extra-low sound levels. MULTISYSTEM OUTDOOR UNITS see page 65 Ţ The white translucent smart DISPLAY provides user with information on the equipment and alarm systems status. When necessary, it can be turned off any time. Ţ Possibility to block the unit for heating-only function. Ţ Drain pipe connection from left or right can be selected. Ţ Louvres position memory. Ţ Compatible with 1x1 and multisystem sets. + COMPATIBLE WITH KC R-01.2 WIRED CONTROLLER ,97 KID-01 S STANDARD CONTROLLERS INDIVIDUAL KC-01.2 R For further information, please see our Controllers range BMS AND SOFTWARE KC-02.1 H K01-WIFI 53 RESIDENTIAL INDOOR UNITS Inspiration, Innovation, Evolution RESIDENTIAL RANGE AUREA MULTISYSTEM POWER RANGE INTRODUCTION TO THE RANGE OF PRODUCTS GROUPS OF UNITS NEW TECHNICAL SPECIFICATIONS MODEL KAY-S 35 DN6 KAY-S 52 DN6 :;;<=>? @BDB@=EF kW 2.78 3.51 5.27 :;;<=>? @BDB@=EF Kcal/h 2224 2808 4216 IJBE=>? @BDB@=EF kW 3.07 3.81 5.56 IJBE=>? @BDB@=EF Kcal/h 2640 3277 4782 V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 3 m /h 490/430/310 500/440/320 710/610/510 dB (A) 21 21 23 [=\U=Z D=DJ Z=B]JEJQ mm (inch) ø6.35 (1/4") 6.35 (1/4) ø6.35 (1/4") ^BT D=DJ Z=B]JEJQ mm (inch) ø9.52 (3/8") ø9.52 (3/8") ø12.7 (1/2") mm 770/295/198 850/300/198 1010/325/230 Kg 7.2 8.5 11.4 K;OJQ O=Q=>? mm2 From outdoor From outdoor From outdoor :;]]U>=@BE=;> O=Q=>? mm2 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5 K;OJQ TUDD<F V=Q X<;O Y;U>Z DQ essure* _=ZE`aIJ=?`E /Depth bJE OJ=?`E * Sound pressure in “Silence” mode. 54 KAY-S 26 DN6 SUITE + OUTDOOR UNIT KEY INSTALLATIONS COMBINED SYSTEMS +* 05=,9;,9 05+669 R410A GENERAL FEATURES The new AUREA model of KAYSUN residential range for 2015, is also fitted with an indoor unit available for the MULTISYSTEM option. This wall-mounted unit replace the former STYLUS 3D. Its new design will undoubtedly get your attention. Ţ MONO and MULTI units are compatible. Ţ WIFI CONTROL, ADDING OPTIONAL K02 WIFI USB connection for both local and remote control of the unit. Ţ Its white translucent smart DISPLAY provides user with information on the equipment and alarm systems status. When necessary, it can be turned off any time. This unit also includes the MUTE mode, which consists in turning the beeper off when it is no longer necessary. Ţ Possibility to block the unit for heating-only function. Ţ Drain pipe connection from left or right can be selected. Ţ Louvres position memory and extremely low sound levels. COMPATIBLE WITH MULTISYSTEM OUTDOOR UNITS see page 65 + + 21 DB sound pressure CONTROLLED BY WIFI NETWORKL (OPTIONAL) NEW NEW OPTIONAL WIFI CONTROL K02 WIFI USB ACCESSORY KID-02 S ,97 STANDARD CONTROLLERS BMS AND SOFTWARE For further information, please see our Controllers range ACCESSORIES NEW K01-WIFI K02 WIFI USB 55 RESIDENTIAL INDOOR UNIT Inspiration, Innovation, Evolution RESIDENTIAL RANGE DOUBLE FLOW CONSOLE POWER RANGE INTRODUCTION TO THE RANGE OF PRODUCTS GROUPS OF UNITS MULTISYSTEM TECHNICAL SPECIFICATIONS MODEL KSD-35 DN6 KSD-52 DMN6 cddefgh ijkjiflm kW 2.64 3.46 5.27 cddefgh ijkjiflm Kcal/h 2270 2976 4532 nojlfgh ijkjiflm kW 2.93 3.46 5.27 nojlfgh ijkjiflm Kcal/h 2520 2976 4532 V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 m³/h 680/580/450 550/470/360 740/650/520 dB (A) 35 35 39 yfztfx kfko xfj{olor mm (inch) ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") |js kfko xfj{olor mm (inch) ø9.52 (3/8") ø9.52 (3/8") ø12.7 (1/2") mm 700/600/210 700/600/210 700/600/210 Kg 13 15 15 pdqor qfrfgh mm2 From outdoor From outdoor From outdoor cd{{tgfijlfdg qfrfgh mm2 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5 pdqor stkkem ufr vedq wdtgx kr essure* }fxl~nofh~l /Depth ol qofh~l *Sound pressure data al low speed. 56 KSD-26 DMN6 SUITE + OUTDOOR UNIT KEY INSTALLATIONS COMBINED SYSTEMS +* 05=,9;,9 05+669 R410A COMPATIBLE WITH GENERAL FEATURES The double flow console has an elegant and compact design that allows for the adaptation thereof to any area to be air-conditioned. It is fitted with the latest technological features, thereby providing users with a high comfort level. Ţ Its 5 speeds DC Inverter fan reduces the unit's sound levels significantly. Ţ Double air intake (upper and lower intake, or just upper intake) and 4-way air intake. Ţ Contacts free from ON/OFF voltage and alarm. Ţ Easy installation. Ţ Optional wired controller. MULTISYSTEM OUTDOOR UNITS see page 65 + DOUBLE AIR INTAKE NEW ,97 KI-02 S (*) RECOMMENDED PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER YOUR If you want a different controller, you shall add to the price the price difference between the SELECT CHOOSE YOUR CONTROLLER recommended controller and the controller you choose. CONTROLLERS For further information, please see our Controllers range INDIVIDUAL CENTRALIZED NEW NEW KCT-02.1 SR KC-02.1 H KC-02 SPS KI-02 S KCCT-64 I KCC-64 I-PS KCC-16 KCC-64 WEB BMS AND SOFTWARE K01-LON K01-MODBUS K01-BACNET KAYNET CONTROL K01-KNX K01-WIFI 57 RESIDENTIAL INDOOR UNIT Inspiration, Innovation, Evolution RESIDENTIAL RANGE POWER RANGE CASSETTE ART FLUX 360º MULTISYSTEM INTRODUCTION TO THE RANGE OF PRODUCTS GROUPS OF UNITS TECHNICAL SPECIFICATIONS MODEL KCI-35 DN9 KCI-52 DMN7 kW 2.63 3.46 5.27 Kcal/h 2262 2976 4532 kW 2.93 4.04 5.27 Kcal/h 2520 3474 4532 V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 3 m /h 680/580/520 650/530/450 800/710/560 dB (A) 36 34 39 mm (inch) ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") mm (inch) ø9.52 (3/8") ø9.52 (3/8") ø12.7 (1/2") mm 570/260/570 570/260/570 570/260/570 Kg 16 16 18 mm 647/50/647 647/50/647 647/50/647 Kg 2.5 2.5 2.5 mm2 From outdoor From outdoor From outdoor mm2 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5 essure* ¡¢£¢ /Depth ¤ ¢ ¢£¢¢£¢ ¢ *Sound pressure data at low speed. 58 KCI-26 DMN7 COMBINED SYSTEMS SUITE + OUTDOOR UNIT KEY INSTALLATIONS +* 05=,9;,9 05+669 GENERAL FEATURES The Cassette Artflux 360º 600x600 units stand out from other units thanks to its elegant design. Their small dimensions allows them for adapting to false ceiling installations and their 360º air flow provides user with highest comfort and covers every corner of the room. Ţ The Cassette 600x600 type units supply 10 % to 15 % of outdoor air flow directly to the unit return system. Ţ They are fitted with an up to 500 mm high standard condensate pump. Ţ The right and left sides of these units' body are designed to connect the necessary piping to air-condition an adjacent room. Ţ The electric box is located at the lower side of the unit to get a more compact size and embed the unit easily in the ceiling. Ţ ON/OFF AND ALARM voltage-free contacts. Ţ Although the 2015 units seem to have the same design, the main body is fitted with a new air channel and a bigger cylinder, making these units 3 db quieter that preceding models. COMPATIBLE WITH + OUTDOOR AIR SUPPLY (10-15%) MULTISYSTEM OUTDOOR UNITS + see page 65 500 mm CONDENSATE PUMP NEW ,97 KI-02 S (*) RECOMMENDED PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you shall add to the price the price difference between the recommended controller and the controller you choose. CONTROLLERS SELECT YOUR CHOOSE YOUR CONTROLLER ¥¦§¨©¦ª For further information, please see our Controllers range INDIVIDUAL CENTRALIZED NEW NEW KCT-02.1 SR KC-02.1 H KC-02 SPS KI-02 S KCCT-64 I KCC-64 I-PS KCC-16 KCC-64 WEB BMS AND SOFTWARE K01-LON K01-MODBUS K01-BACNET KAYNET CONTROL K01-KNX K01-WIFI 59 RESIDENTIAL INDOOR UNIT Inspiration, Innovation, Evolution RESIDENTIAL RANGE DUCTS POWER RANGE INTRODUCTION TO THE RANGE OF PRODUCTS GROUPS OF UNITS MULTISYSTEM TECHNICAL SPECIFICATIONS MODEL KPD-26 DMN6 KPD-35 DN9 KPD-52 DMN6 «¬¬®¯° ±²³²±®´µ kW 2.05 2.63 3.5 5.27 «¬¬®¯° ±²³²±®´µ Kcal/h 1763 2262 3010 4532 ¶·²´®¯° ±²³²±®´µ kW 2.34 2.93 3.5 5.86 ¶·²´®¯° ±²³²±®´µ Kcal/h 2012 2520 3010 5040 V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 m3/h 720/600/540 720/600/540 640/550/470 1400/1100/1000 Pa 40 40 45 70 dB (A) 34 34 35 40 Á®Â¼®À ³®³· À®²Ã·´·º mm (inch) ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") IJ» ³®³· À®²Ã·´·º mm (inch) ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø12.7 (1/2") mm 700/210/635 700/210/635 700/210/635 920/210/635 Kg 19.5 19.5 18 ¸¬¹·º »¼³³µ ½®º ¾¬¹ ¿´²´®± ¸º·»»¼º· (high speed) ¿¬¼¯À ³º essure* Å®À´ÆǶ·®°Æ´ /Depth È·´ ¹·®°Æ´ 33 23 ¸¬¹·º ¹®º®¯° mm2 From outdoor From outdoor From outdoor From outdoor «¬Ãü¯®±²´®¬¯ ¹®º®¯° mm (3+T)x2.5 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5 *Sound pressure data at low speed. 60 KPD-20 DMN6 2 COMBINED SYSTEMS SUITE + OUTDOOR UNIT KEY INSTALLATIONS +* 05=,9;,9 05+669 GENERAL FEATURES Ţ The inclined position of the KAYSUN Ducts units provides them with a slim design. This feature allows for installing Ducts units in areas where the false ceiling is too narrow. Ţ The electric box of Duct type indoor units is removable up to 1 metre. Ţ ON/OFF AND ALARM voltage-free contacts Ţ The filter is easy to remove even when piping is done. Ţ Standard condensation pump. Ţ All units include an air inlet/outlet pre-installation to facilitate the fitting of the tubes that guarantee air circulation. Ţ Possibility for double air intake (rear or lower intake) that can be easily arranged. Ţ Outdoor air intake to treat air with indoor unit's battery and blow it into the room through the air line. + + COMPATIBLE WITH MULTISYSTEM OUTDOOR UNITS see page 65 750mm CONDENSATION PUMP OUTDOOR AIR INTAKE Compatible with KC-02 SPS ,97 (*) RECOMMENDED PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you shall add to the price the price difference between the SELECT YOUR CHOOSE YOUR recommended controller and the controller you choose. CONTROLLER ÉÊËÌÍÊÎ CONTROLLERS For further information, please see our Controllers range INDIVIDUAL CENTRALIZED NEW KCT-02.1 SR KC-02.1 H KC-02 SPS NEW KCCT-64 I KCC-64 I-PS KCC-16 KCC-64 WEB KI-02 S BMS AND SOFTWARE K01-LON K01-MODBUS K01-BACNET KAYNET CONTROL K01-WIFI K01-KNX RE SU ES R P HS IC P AT GRA 61 ST RESIDENTIAL INDOOR UNIT Inspiration, Innovation, Evolution RESIDENTIAL RANGE DUCTS INTRODUCTION TO THE RANGE OF PRODUCTS POWER RANGE STATIC PRESSURE GRAPHS Air flow (m3/h) External static pressure (Pa) KPD 52 DMN6 Air flow (m3/h) 62 KPD-26 DMN6 External static pressure (Pa) External static pressure (Pa) KPD 20 DMN6 Air flow (m3/h) GROUPS OF UNITS + COMBINED SYSTEMS SUITE OUTDOOR UNIT KEY INSTALLATIONS KPD-35 DN9 Medium External static pressure (Pa) External static pressure (Pa) High Air flow (m3/h) Air flow (m3/h) External static pressure (Pa) Low Air flow (m3/h) 63 RESIDENTIAL INDOOR UNIT Inspiration, Innovation, Evolution RESIDENTIAL RANGE OUTDOOR UNIT MULTIPLE OPTIONS INTRODUCTION TO THE RANGE OF PRODUCTS POWER RANGE GROUPS OF UNITS MULTISYSTEM NEW The SUITE MULTISYSTEM outdoor unit, allows arranging installations with multiple compatible indoor units. This year we broad the indoor units range with the introduction of the AUREA model, a wall-mounted unit that is extremely quiet. As an option, this unit can be locally or remotely controlled through a WIFI network by means of a small controller that is sold separately. The MULTISYSTEM units provide user with a high comfort level by means of its multiple systems and the built-in DC INVERTER compressor and fan, which also allows a very accurate and balanced adjustments. MULTISYSTEM COMBINABLE NEW NEW NEW COMBINABLE COMBINABLE COMBINABLE Compatible with 64 Compatible with Compatible with + SUITE OUTDOOR UNIT KEY INSTALLATIONS COMBINED SYSTEMS +* 05=,9;,9 +* 05=,9;,9 +* 05=,9;,9 6<;+669 <50; R410A GENERAL FEATURES Ţ All units are equipped with a single fan. Ţ Outdoor units have as many expansion valves as number of indoor units allowed. Ţ Capacity range from 4.8 kW to 12 kW and, depending on power, up to 5 indoor units can be combined. Ţ Versatility in cooling distances, with the potential to go as far as 75 meters depending on the model. + 1 n VALVES AS n INDOOR UNITS FAN ,97 L ICA HN RES C TE ATU 65 FE RESIDENTIAL INDOOR UNIT Inspiration, Innovation, Evolution RESIDENTIAL RANGE OUTDOOR UNIT INTRODUCTION TO THE RANGE OF PRODUCTS POWER RANGE GROUPS OF UNITS MULTISYSTEM TECHNICAL SPECIFICATIONS MODEL KAM2-48 DN6 KAM2-52 DN6 KAM3-62 DN5 KAM3-78 DN6 ÏÐÐÑÒÓÔ ÕÖ×ÖÕÒØÙ kW 4.68 5.24 6.15 7.62 ÏÐÐÑÒÓÔ ÕÖ×ÖÕÒØÙ Kcal/h 4024.8 4506.4 5289 6553.2 ÏÐÐÑÒÓÔ ÒÓ×ÚØ kW 1.35 1.65 1.91 2.4 ÛÜÖØÒÓÔ ÕÖ×ÖÕÒØÙ kW 5.2 5.9 6.7 7.9 ÛÜÖØÒÓÔ ÕÖ×ÖÕÒØÙ Kcal/h 4429 5040 5796 6803 kW 1.42 1.37 1.75 1.81 V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Rotary Rotary Double rotary Double rotary ÛÜÖØÒÓÔ ÒÓ×ÚØ ÝÐÞÜß supply ÏÐà×ßÜááÐß ØÙ×Ü flow m3/h 2100 2100 2700 2700 essure dB (A) 56 56 59 58 R-410 R-410 R-410 R-410 gr 1700 2000 2100 2100 m 10 10 15 15 øîùæîè éîéì èîðõìñìê mm (Inch) ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") úðö éîéì èîðõìñìê mm (Inch) ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") m 30 30 45 45 m 20 20 25 25 m 15 15 15 15 m 10 10 10 10 mm 810/558/310 810/558/310 845/700/320 845/700/320 Kg 35 37 50 50 2 2 3 3 mm2 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x4 mm2 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5 (3+T)x2.5 âÚØãÐÐß ÖÒß äåæçè éê ëìíêîïìêðçñ ëìíêîïìêðçñ pre charge* òêì óôðêïì õìñêìö÷ òîéîçï õð x. length x. length (1 indoor) ûìîïôñ èîüerence between indoor and outdoor units ûìîïôñ èîüerence between indoor units òîéîçï õð ýîèñôþûìîïôñ /Depth ÿìñ Nìîïôñ Mð îõæõ ðõåæçñ åí indoor units òåNìê wiring Cåõõæçîóðñîåç wiring Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating) *To calculate the additional charge necessary for these units, we applied the following formula: ADDITIONAL (GR) = (TOTAL LENGTH OF ALL CIRCUITS' LIQUID LINE - FACTORY PRE-CHARGE METRES) x 15 Grams. Note: Standard performance data; definitive performance data depend on the indoor units combination. 66 + COMBINED SYSTEMS SUITE OUTDOOR UNIT KEY INSTALLATIONS KAM4-80 DN5 KAM4-105 DN5 KAM5-105-105 DN5 KAM5-120 DN5 8.2 10.55 10.55 1 7052 9073 9073 155.4 2.47 3.28 3.28 3 9.1 12.0 12.3 1 7809 10329 10587 131 2.44 3.33 3.4 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Double rotary Double rotary Double rotary Double rotary 3800 5500 5500 61 64 65 R-410 R-410 R-410 R-410 2400 2700 3000 20 20 25 ø6.35 (1/4") ø6.35 (1/4") ø6.35 (1/4") ø5 (1/4") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø 9 60 60 75 3 30 30 30 15 15 15 1 10 10 10 1 895/860/315 990/965/345 990/965/345 65 78 80 4 4 5 (2+T)x4 (2+T)x6 (2+T)x6 9( (3+T)x2.5 (3+T)x2.5 (3+T)x2.5 9( ED N B I MS M E C O YST 67 S RESIDENTIAL INDOOR UNIT Inspiration, Innovation, Evolution INTRODUCTION TO THE RANGE OF PRODUCTS RESIDENTIAL RANGE COMBINED SYSTEMS KAM2-48 DN6 x1 x2 20 20+20 26 20+26 35 20+35 52 20+52 26+26 26+35 KAM2-52 DN6 x1 x2 20 20+20 26 20+26 35 20+35 52 20+52 26+26 26+35 26+52 35+35 68 POWER RANGE GROUPS OF UNITS UNIT A UNIT B UNIT A RATED MAXIMUM MINIMUM RATED MAXIMUM SUITE EER (W/W) ENERGY CLASS RATED CAPACITY 20 2.20 2.20 2.22 4.40 4.53 0.61 1.46 1.71 5,61 2.87 B 26 2.07 2.68 2.39 4.75 4.89 0.65 1.54 1.78 - 2.93 B 20 35 1.98 3.17 2.60 5.15 5.30 0.67 1.58 1.86 - 3.09 A 20 52 1.51 4.00 2.78 5.51 5.67 0.72 1.71 1.98 - 3.06 A 26 26 2.60 2.60 2.62 5.20 5.39 0.68 1.62 1.87 - 3.05 A 26 35 2.42 2.98 2.72 5.40 5.55 0.70 1.66 1.92 - 3.09 A RATED POWER (kW) UNIT A UNIT B UNIT A UNIT B HEATING CAPACITY (kW) MINIMUM RATED INPUT POWER (kW) MAXIMUM MINIMUM RATED SCOP (W/W) MAXIMUM COP (W/W) ENERGY CLASS COP -7 2.24 RATED CAPACITY 20 20 2.40 2.40 2.42 4.80 4.94 0.62 1.48 1.74 3,80 3.08 C 20 26 2.24 2.91 2.60 5.15 5.30 0.67 1.60 1.85 - 3.06 C 2.23 20 35 2.33 3.72 3.05 6.05 6.22 0.70 1.68 1.94 - 3.43 A 2.49 20 52 1.78 4.70 3.27 6.48 6.66 0.75 1.78 2.02 - 3.46 A 2.52 26 26 3.05 3.05 3.07 6.10 6.27 0.70 1.67 1.93 - 3.47 A 2.52 26 35 2.82 3.46 3.17 6.28 6.46 0.73 1.73 1.98 - 3.45 A 2.51 RATED POWER (kW) UNIT A UNIT B UNIT A COOLING CAPACITY (kW) UNIT B MINIMUM RATED INPUT POWER (kW) MAXIMUM MINIMUM RATED SEER (W/W) MAXIMUM EER (W/W) ENERGY CLASS RATED CAPACITY 20 20 2.20 2.20 1.85 4.40 5.32 0.58 1.46 1.82 - 3.02 B 20 26 2.07 2.68 2.00 4.75 5.75 0.62 1.54 1.90 - 3.08 B A 20 35 1.98 3.17 2.16 5.15 6.23 0.63 1.58 1.98 - 3.25 20 52 1.51 4.00 2.31 5.51 6.67 0.68 1.71 2.10 - 3.22 A 26 26 2.60 2.60 2.18 5.20 6.34 0.65 1.62 1.99 5,63 3.21 A 26 35 2.42 2.98 2.27 5.40 6.53 0.66 1.66 2.04 - 3.25 A 35 35 2.73 2.73 2.29 5.46 6.61 0.67 1.67 2.06 - 3.26 A 35 35 3.30 3.30 4.62 6.60 6.70 1.100 2.050 2.094 - 3.22 A COMBINATIONS 1x2 MINIMUM SEER (W/W) 20 COMBINATIONS 1x2 UNIT B INPUT POWER (kW) 20 COMBINATIONS 1x2 KEY INSTALLATIONS COMBINED SYSTEMS COOLING CAPACITY (kW) RATED POWER (kW) COMBINATIONS 1x2 + OUTDOOR UNIT RATED POWER (kW) HEATING CAPACITY (kW) INPUT POWER (kW) UNIT A UNIT B UNIT A UNIT B MINIMUM RATED MAXIMUM MINIMUM 20 20 2.40 2.40 2.02 4.80 5.81 20 26 2.24 2.91 2.16 5.15 6.23 20 35 2.33 3.72 2.54 6.05 7.32 SCOP (W/W) COP (W/W) ENERGY CLASS COP -7 2.24 RATED MAXIMUM RATED CAPACITY 0.59 1.48 1.85 - 3.24 C 0.64 1.60 1.97 - 3.22 C 2.23 0.67 1.68 2.06 - 3.61 A 2.49 20 52 1.78 4.70 2.72 6.48 7.84 0.71 1.78 2.15 - 3.64 A 2.52 26 26 3.05 3.05 2.56 6.10 7.38 0.67 1.67 2.06 3,82 3.65 A 2.52 26 35 2.82 3.46 2.64 6.28 7.60 0.69 1.73 2.11 - 3.63 A 2.51 35 35 3.21 3.21 2.70 6.42 7.77 0.71 1.77 2.14 - 3.63 A 2.51 69 RESIDENTIAL INDOOR UNIT Inspiration, Innovation, Evolution INTRODUCTION TO THE RANGE OF PRODUCTS RESIDENTIAL RANGE POWER RANGE COMBINED SYSTEMS KAM3-62 DN5 x1 x2 x3 20 20+20 20+20+20 26 20+26 20+20+26 35 20+35 20+20+35 52 20+52 20+26+26 26+26 20+26+35 26+35 26+26+26 26+52 26+26+35 35+35 70 GROUPS OF UNITS RATED POWER (kW) COMBINATIONS UNIT A UNIT B UNIT C UNIT A UNIT B KEY INSTALLATIONS COMBINED SYSTEMS COOLING CAPACITY (kW) UNIT C MINIMUM RATED SUITE + OUTDOOR UNIT INPUT POWER (kW) MAXIMUM MINIMUM SEER (W/W) RATED MAXIMUM EER (W/W) ENERGY CLASS RATED CAPACITY 20 20 20 2.05 2.05 2.05 2.58 6.15 7.44 0.76 1.91 2.54 5,42 3.22 A 20 20 26 1.93 1.93 2.51 2.68 6.38 7.72 0.79 1.98 2.64 - 3.22 A 20 20 35 1.84 1.84 2.94 2.78 6.62 8.01 0.82 2.05 2.73 - 3.23 A 20 26 26 1.84 2.39 2.39 2.78 6.62 8.01 0.82 2.05 2.73 - 3.23 A 20 26 35 1.78 2.32 2.85 2.92 6.95 8.41 0.86 2.15 2.86 - 3.23 A 26 26 26 2.32 2.32 2.32 2.92 6.95 8.41 0.86 2.15 2.86 - 3.23 A 26 26 35 2.28 2.28 2.81 3.10 7.38 8.93 0.91 2.28 3.03 - 3.24 A SCOP (W/W) COP (W/W) ENERGY CLASS COP -7 1x3 RATED POWER (kW) COMBINATIONS UNIT A UNIT B UNIT C UNIT A HEATING CAPACITY (kW) UNIT B UNIT C MINIMUM INPUT POWER (kW) RATED MAXIMUM MINIMUM RATED MAXIMUM RATED CAPACITY 20 20 20 2.25 2.25 2.25 2.83 6.74 8.16 0.74 1.86 2.51 3,83 3.62 A 2.78 20 20 26 2.05 2.05 2.67 2.85 6.78 8.20 0.75 1.87 2.53 - 3.62 A 2.78 20 20 35 1.95 1.95 3.12 2.95 7.02 8.49 0.77 1.93 2.61 - 3.63 A 2.79 20 26 26 1.95 2.54 2.54 2.95 7.02 8.49 0.77 1.93 2.61 - 3.63 A 2.79 20 26 35 1.89 2.45 3.02 3.09 7.36 8.91 0.81 2.03 2.74 - 3.63 A 2.79 26 26 26 2.45 2.45 2.45 3.09 7.36 8.91 0.81 2.03 2.74 - 3.63 A 2.78 26 26 35 2.38 2.38 2.93 3.23 7.70 9.32 0.85 2.12 2.86 - 3.64 A 2.79 1x3 71 RESIDENTIAL INDOOR UNIT Inspiration, Innovation, Evolution INTRODUCTION TO THE RANGE OF PRODUCTS RESIDENTIAL RANGE POWER RANGE COMBINED SYSTEMS KAM3-78 DN6 x1 x2 x3 20 20+20 20+20+20 26 20+26 20+20+26 35 20+35 20+20+35 52 20+52 20+20+52 26+26 20+26+26 26+35 20+26+35 26+52 20+35+35 35+35 26+26+26 35+52 26+26+35 26+35+35 72 GROUPS OF UNITS RATED POWER (kW) COMBINATIONS UNIT A UNIT B UNIT C 20 1x3 UNIT A UNIT B UNIT C 20 2.20 2.20 2.20 SUITE KEY INSTALLATIONS COMBINED SYSTEMS COOLING CAPACITY (kW) 20 INPUT POWER (kW) SEER (W/W) MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUM 3.05 6.60 7.59 0.99 2.14 2.61 EER (W/W) ENERGY CLASS RATED CAPACITY - 3.23 B 20 20 26 2.04 2.04 2.65 3.10 6.72 7.72 1.00 2.17 2.64 - 3.26 B 20 20 35 2.07 2.07 3.31 3.44 7.45 8.56 1.07 2.32 2.82 - 3.37 A 20 20 52 1.76 1.76 4.66 3.78 8.18 9.40 1.15 2.50 2.92 - 3.43 A 20 26 26 2.07 2.69 2.69 3.44 7.45 8.56 1.07 2.32 2.76 - 3.37 A 20 26 35 2.00 2.60 3.20 3.60 7.80 8.97 1.10 2.39 2.84 - 3.42 A 20 35 35 1.93 3.09 3.09 3.74 8.10 9.31 1.14 2.48 2.90 - 3.42 A 26 26 26 2.60 2.60 2.60 3.60 7.80 8.97 1.10 2.40 2.85 5,62 3.41 A 26 26 35 2.51 2.51 3.09 3.74 8.10 9.31 1.14 2.48 2.90 - 3.42 A 26 35 35 2.35 2.90 2.90 3.77 8.15 9.37 1.16 2.52 2.96 - 3.40 A RATED POWER (kW) COMBINATIONS UNIT A 20 1x3 + OUTDOOR UNIT UNIT B UNIT C UNIT A UNIT B 20 20 2.37 2.37 HEATING CAPACITY (kW) UNIT C 2.37 MINIMUM RATED 3.28 7.10 INPUT POWER (kW) MAXIMUM MINIMUM 7.73 0.99 SCOP (W/W) RATED MAXIMUM 2.07 2.91 COP (W/W) ENERGY CLASS COP -7 B 2.69 RATED CAPACITY - 3.60 20 20 26 2.27 2.27 2.95 3.47 7.50 8.17 1.05 2.19 3.09 - 3.59 B 2.69 20 20 35 2.31 2.31 3.69 3.83 8.30 9.04 1.13 2.36 3.24 - 3.70 B 2.69 20 20 52 1.96 1.96 5.19 4.20 9.10 10.48 1.21 2.52 3.38 - 3.79 A 2.69 20 26 26 2.31 3.00 3.00 3.83 8.30 9.04 1.13 2.36 3.24 - 3.70 B 2.69 20 26 35 2.24 2.92 3.59 4.04 8.75 9.53 1.17 2.43 3.34 - 3.78 A 2.69 20 35 35 2.15 3.45 3.45 4.18 9.05 9.86 1.20 2.49 3.37 - 3.81 A 2.69 26 26 26 2.92 2.92 2.92 4.04 8.75 9.53 1.16 2.42 3.32 3,84 3.80 A 2.69 26 26 35 2.80 2.80 3.45 4.18 9.05 9.86 1.20 2.49 3.37 - 3.81 A 2.70 26 35 35 2.63 3.24 3.24 4.20 9.10 9.91 1.20 2.49 3.37 - 3.83 A 2.70 73 RESIDENTIAL INDOOR UNIT Inspiration, Innovation, Evolution INTRODUCTION TO THE RANGE OF PRODUCTS RESIDENTIAL RANGE POWER RANGE GROUPS OF UNITS COMBINED SYSTEMS KAM4-80 DN5 x1 x2 x3 x4 20 20+20 20+20+20 20+20+20+20 26 20+26 20+20+26 20+20+20+26 35 20+35 20+20+35 20+20+20+35 52 20+52 20+20+52 20+20+20+52 26+26 20+26+26 20+20+26+26 26+35 20+26+35 20+20+26+35 26+52 20+26+52 20+20+35+35 35+35 20+35+35 20+26+26+26 35+52 20+35+52 20+26+26+35 52+52 26+26+26 20+26+35+35 26+26+35 26+26+26+26 26+26+52 26+26+26+35 26+35+35 26+35+52 35+35+35 74 COMBINATIONS RATED CAPACITY (KW); COMBINED SYSTEMS KEY INSTALLATIONS COOLING CAPACITY (KW) INPUT POWER (KW) SUITE + OUTDOOR UNIT SEER (W/W) EER (W/W) ENERGY CLASS UNIT A UNIT B UNIT C UNIT D UNIT A UNIT B UNIT C UNIT D MINIMUM RATED MAXIMUM MINIMUM RATED MAXIMUM 20 20 20 20 1.98 1.98 1.98 1.98 2.45 7.91 9.65 0.98 2.47 3.33 5,62 3.20 A 20 20 20 26 1.90 1.90 1.90 2.46 3.34 8.15 9.94 1.02 2.54 3.43 - 3.21 A 20 20 20 35 1.90 1.90 1.90 3.04 3.59 8.75 10.68 1.09 2.72 3.67 - 3.22 A 20 20 20 52 1.61 1.61 1.61 4.28 3.74 9.12 11.13 1.11 2.78 3.75 - 3.28 A 20 20 26 26 1.90 1.90 2.47 2.47 3.59 8.75 10.68 1.09 2.72 3.67 - 3.22 A 20 20 26 35 1.83 1.83 2.38 2.93 3.67 8.96 10.93 1.11 2.77 3.74 - 3.23 A 20 20 35 35 1.73 1.73 2.78 2.78 3.70 9.02 11.00 1.11 2.78 3.75 - 3.25 A 20 26 26 26 1.83 2.38 2.38 2.38 3.67 8.96 10.93 1.11 2.77 3.74 - 3.23 A 20 26 26 35 1.73 2.26 2.26 2.78 3.70 9.02 11.00 1.11 2.78 3.75 - 3.25 A 20 26 35 35 1.65 2.15 2.64 2.64 3.73 9.09 11.09 1.11 2.78 3.75 - 3.27 A 26 26 26 26 2.26 2.26 2.26 2.26 3.70 9.02 11.00 1.11 2.78 3.75 - 3.25 A 26 26 26 35 2.15 2.15 2.15 2.64 3.73 9.09 11.09 1.11 2.78 3.75 - 3.27 A RATED CAPACITY 1x4 COMBINATIONS 1x4 HEATING CAPACITY (KW) RATED CAPACITY (KW); UNIT A UNIT B UNIT C UNIT D UNIT A UNIT B UNIT C UNIT D 20 20 20 20 2.20 2.20 2.20 2.20 2.85 20 20 20 26 2.06 2.06 2.06 2.68 20 20 20 35 2.04 2.04 2.04 20 20 20 52 1.79 1.79 20 20 26 26 2.07 20 20 26 35 20 20 35 20 26 20 MINIMUM RATED INPUT POWER (KW) SCOP (W/W) COP (W/W) ENERGY CLASS COP -7 RATED CAPACITY MAXIMUM MINIMUM RATED MAXIMUM 8.79 10.72 0.91 2.44 3.27 3,85 3.60 A 2.77 3.63 8.86 10.81 0.98 2.45 3.28 - 3.62 A 2.78 3.26 3.85 9.38 11.44 1.04 2.59 3.47 - 3.62 A 2.78 1.79 4.75 4.15 10.13 12.36 1.11 2.78 3.73 - 3.64 A 2.79 2.07 2.69 2.69 3.90 9.51 11.60 1.05 2.63 3.52 - 3.62 A 2.78 1.99 1.99 2.59 3.19 4.00 9.76 11.91 1.08 2.70 3.61 - 3.62 A 2.78 35 1.91 1.91 3.05 3.05 4.07 9.92 12.10 1.09 2.73 3.66 - 3.63 A 2.79 26 26 1.99 2.59 2.59 2.59 4.00 9.76 11.91 1.08 2.70 3.61 - 3.62 A 2.78 26 26 35 1.91 2.48 2.48 3.05 4.07 9.92 12.10 1.09 2.73 3.66 - 3.63 A 2.79 20 26 35 35 1.83 2.38 2.93 2.93 4.13 10.08 12.30 1.11 2.78 3.72 - 3.63 A 2.79 26 26 26 26 2.48 2.48 2.48 2.48 4.07 9.92 12.10 1.09 2.73 3.66 - 3.63 A 2.79 26 26 26 35 2.38 2.38 2.38 2.93 4.13 10.08 12.30 1.11 2.78 3.72 - 3.63 A 2.79 75 RESIDENTIAL INDOOR UNIT Inspiration, Innovation, Evolution INTRODUCTION TO THE RANGE OF PRODUCTS RESIDENTIAL RANGE POWER RANGE GROUPS OF UNITS COMBINED SYSTEMS KAM4-105 DN5 x1 x2 x3 x4 20 20+20 20+20+20 20+20+20+20 26 20+26 20+20+26 20+20+20+26 35 20+35 20+20+35 20+20+20+35 52 20+52 20+20+52 20+20+20+52 26+26 20+26+26 20+20+26+26 26+35 20+26+35 20+20+26+35 26+52 20+26+52 20+20+26+52 35+35 20+35+35 20+20+35+35 35+52 20+35+52 20+20+35+52 52+52 20+52+52 20+20+52+52 26+26+26 20+26+26+26 26+26+35 20+26+26+35 26+26+52 20+26+26+52 26+35+35 20+26+35+35 26+35+52 20+26+35+52 26+52+52 20+26+52+52 35+35+35 20+35+35+35 35+35+52 20+35+35+52 35+52+52 26+26+26+26 26+26+26+35 26+26+26+52 26+26+35+35 26+26+35+52 26+35+35+35 26+35+35+52 35+35+35+35 35+35+35+52 76 RATED POWER (kW) COMBINATIONS 1X4 COOLING CAPACITY (kW) RATED INPUT POWER (kW) SEER (W/W) MAXIMUM MINIMUM RATED MAXIMUM EER (W/W) ENERGY CLASS RATED CAPACITY 20 20 20 20 2.04 2.04 2.04 2.04 3.34 8.15 9.78 1.24 2.96 3.62 - 2.75 D 20 20 20 26 1.90 1.90 1.90 2.46 3.34 8.15 9.78 1.24 2.96 3.62 - 2.75 D 20 20 20 35 2.12 2.12 2.12 3.39 4.00 9.75 11.70 1.42 3.37 4.12 - 2.89 C 20 20 20 52 1.96 1.96 1.96 5.18 4.53 11.05 13.26 1.51 3.60 4.39 - 3.07 B 20 20 26 26 2.12 2.12 2.76 2.76 4.00 9.75 11.70 1.42 3.37 4.12 - 2.89 C 20 20 26 35 2.14 2.14 2.79 3.43 4.31 10.50 12.60 1.45 3.45 4.21 - 3.04 B 20 20 26 52 1.86 1.86 2.41 4.92 4.53 11.05 13.26 1.51 3.60 4.39 - 3.07 B 20 20 35 35 2.02 2.02 3.23 3.23 4.31 10.50 12.60 1.45 3.45 4.21 - 3.04 B 20 20 35 52 1.84 1.84 2.95 4.88 4.72 11.52 13.82 1.57 3.74 4.56 - 3.08 B 20 20 52 52 1.67 1.67 4.41 4.41 4.99 12.16 14.59 1.61 3.82 4.67 - 3.18 B 20 26 26 26 2.14 2.79 2.79 2.79 4.31 10.50 12.60 1.42 3.39 4.13 - 3.10 B 20 26 26 35 2.02 2.63 2.63 3.23 4.31 10.50 12.60 1.45 3.45 4.21 - 3.04 B 20 26 26 52 1.84 2.40 2.40 4.88 4.72 11.52 13.82 1.57 3.74 4.56 - 3.08 B 20 26 35 35 2.01 2.61 3.21 3.21 4.53 11.05 13.26 1.51 3.60 4.39 - 3.07 B 20 26 35 52 1.81 2.35 2.89 4.79 4.85 11.84 14.21 1.59 3.78 4.61 - 3.13 B B 20 26 52 52 1.56 2.03 4.13 4.13 4.85 11.84 14.21 1.59 3.78 4.61 - 3.13 20 35 35 35 1.91 3.05 3.05 3.05 4.53 11.05 13.26 1.51 3.60 4.39 - 3.07 B 20 35 35 52 1.73 2.77 2.77 4.58 4.85 11.84 14.21 1.59 3.78 4.61 - 3.13 B 26 26 26 26 2.63 2.63 2.63 2.63 4.31 10.50 12.81 1.38 3.45 4.32 5,11 3.04 B 26 26 26 35 2.61 2.61 2.61 3.21 4.53 11.05 13.26 1.51 3.60 4.39 - 3.07 B 26 26 26 52 2.29 2.29 2.29 4.66 4.72 11.52 13.82 1.57 3.74 4.56 - 3.08 B 26 26 35 35 2.48 2.48 3.05 3.05 4.53 11.05 13.26 1.51 3.60 4.39 - 3.07 B 26 26 35 52 2.25 2.25 2.77 4.58 4.85 11.84 14.21 1.59 3.78 4.61 - 3.13 B 26 35 35 35 2.46 3.02 3.02 3.02 4.72 11.52 13.82 1.57 3.74 4.56 - 3.08 B 26 35 35 52 2.15 2.65 2.65 4.39 4.85 11.84 14.21 1.59 3.78 4.61 - 3.13 B 35 35 35 35 2.88 2.88 2.88 2.88 4.72 11.52 13.82 1.57 3.74 4.56 - 3.08 B 35 35 35 52 2.61 2.61 2.61 4.33 4.99 12.16 14.59 1.61 3.82 4.67 - 3.18 B RATED POWER (kW) COMBINATIONS HEATING CAPACITY (kW) UNIT A UNIT B UNIT C UNIT D UNIT A UNIT B UNIT C UNIT D MINIMUM 1X4 KEY INSTALLATIONS COMBINED SYSTEMS UNIT A UNIT B UNIT C UNIT D UNIT A UNIT B UNIT C UNIT D MINIMUM SUITE + OUTDOOR UNIT RATED INPUT POWER (kW) MAXIMUM MINIMUM SCOP (W/W) RATED MAXIMUM COP (W/W) ENERGY CLASS COP -7 RATED CAPACITY 20 20 20 20 2.21 2.21 2.21 2.21 3.70 8.82 10.67 0.99 2.47 3.01 - 2.91 D 2.77 20 20 20 26 2.05 2.05 2.05 2.67 3.70 8.82 10.67 0.99 2.47 3.01 - 2.91 D 2.78 20 20 20 35 2.36 2.36 2.36 3.77 4.56 10.85 13.13 1.44 3.59 4.38 - 3.02 D 2.78 20 20 20 52 1.98 1.98 1.98 5.23 4.69 11.16 13.50 1.36 3.40 4.15 - 3.28 C 2.79 20 20 26 26 2.36 2.36 3.07 3.07 4.56 10.85 13.13 1.44 3.59 4.38 - 3.02 D 2.78 20 20 26 35 2.27 2.27 2.94 3.62 4.66 11.10 13.43 1.35 3.38 4.13 - 3.28 C 2.78 20 20 26 52 1.88 1.88 2.44 4.97 4.69 11.16 13.50 1.36 3.40 4.15 - 3.28 C 2.79 20 20 35 35 2.13 2.13 3.42 3.42 4.66 11.10 13.43 1.35 3.38 4.13 - 3.28 C 2.78 20 20 35 52 1.86 1.86 2.98 4.93 4.88 11.63 14.07 1.41 3.51 4.29 - 3.31 C 2.79 20 20 52 52 1.82 1.82 4.81 4.81 5.57 13.25 16.03 1.58 3.94 4.81 - 3.36 C 2.79 20 26 26 26 2.27 2.94 2.94 2.94 4.66 11.10 13.43 1.35 3.38 4.13 - 3.28 C 2.79 20 26 26 35 2.13 2.78 2.78 3.42 4.66 11.10 13.43 1.35 3.38 4.13 - 3.28 C 2.79 20 26 26 52 1.86 2.42 2.42 4.93 4.88 11.63 14.07 1.41 3.51 4.29 - 3.31 C 2.78 20 26 35 35 2.03 2.64 3.25 3.25 4.69 11.16 13.50 1.36 3.40 4.15 - 3.28 C 2.80 20 26 35 52 1.81 2.35 2.89 4.79 4.97 11.84 14.33 1.51 3.78 4.61 - 3.13 D 2.81 20 26 52 52 1.56 2.03 4.13 4.13 4.97 11.84 14.33 1.51 3.78 4.61 - 3.13 D 2.79 20 35 35 35 1.92 3.08 3.08 3.08 4.69 11.16 13.50 1.36 3.40 4.15 - 3.28 C 2.80 20 35 35 52 1.76 2.81 2.81 4.66 5.06 12.04 14.57 1.45 3.64 4.44 - 3.31 C 2.79 26 26 26 26 2.78 2.78 2.78 2.78 4.55 11.10 13.43 1.35 3.38 4.13 3,80 3.28 C 2.78 26 26 26 35 2.64 2.64 2.64 3.25 4.69 11.16 13.50 1.36 3.40 4.15 - 3.28 C 2.78 26 26 26 52 2.31 2.31 2.31 4.71 4.88 11.63 14.07 1.41 3.51 4.29 - 3.31 C 2.78 26 26 35 35 2.50 2.50 3.08 3.08 4.69 11.16 13.50 1.36 3.40 4.15 - 3.28 C 2.78 26 26 35 52 2.28 2.28 2.81 4.66 5.06 12.04 14.57 1.45 3.64 4.44 - 3.31 C 2.79 26 35 35 35 2.48 3.05 3.05 3.05 4.88 11.63 14.07 1.41 3.51 4.29 - 3.31 C 2.79 26 35 35 52 2.19 2.69 2.69 4.46 5.06 12.04 14.57 1.45 3.64 4.44 - 3.31 C 2.79 35 35 35 35 2.91 2.91 2.91 2.91 4.88 11.63 14.07 1.41 3.51 4.29 - 3.31 C 2.79 35 35 35 52 2.85 2.85 2.85 4.71 5.57 13.25 16.03 1.58 3.94 4.81 - 3.36 C 2.79 77 RESIDENTIAL INDOOR UNIT Inspiration, Innovation, Evolution RESIDENTIAL RANGE INTRODUCTION TO THE RANGE OF PRODUCTS POWER RANGE GROUPS OF UNITS COMBINED SYSTEMS KAM5-105 DNS x1 x2 x4 x5 20 20+20 20+20+20 20+20+20+20 20+20+20+20+20 26 20+26 20+20+26 20+20+20+26 20+20+20+20+26 35 20+35 20+20+35 20+20+20+35 20+20+20+20+35 52 20+52 20+20+52 20+20+20+52 20+20+20+20+52 26+26 20+26+26 20+20+26+26 20+20+20+26+26 26+35 20+26+35 20+20+26+35 20+20+20+26+35 26+52 20+26+52 20+20+26+52 20+20+20+26+52 35+35 20+35+35 20+20+35+35 20+20+20+35+52 35+52 20+35+52 20+20+35+52 20+20+20+52+52 52+52 78 x3 20+52+52 20+20+52+52 20+20+26+26+26 26+26+26 20+26+26+26 20+20+26+26+35 26+26+35 20+26+26+35 20+20+26+26+52 26+26+52 20+26+26+52 20+20+26+35+52 26+35+35 20+26+35+35 20+20+35+35+52 26+35+52 20+26+35+52 20+26+26+26+26 26+52+52 20+26+52+52 20+26+26+26+35 35+35+35 20+35+35+35 20+26+26+26+52 35+35+52 20+35+35+52 20+26+26+35+35 35+52+52 20+35+52+52 20+26+26+35+52 26+26+26+26 20+26+35+35+35 26+26+26+35 20+26+35+35+52 26+26+26+52 26+26+26+26+26 26+26+35+35 26+26+26+26+35 26+26+35+52 26+26+26+26+52 26+26+52+52 26+26+26+35+35 26+35+35+35 26+26+26+35+52 26+35+35+52 26+26+35+35+35 35+35+35+35 26+35+35+35+35 35+35+35+52 35+35+35+35+35 UNIT A UNIT B UNIT C 20 20 20 20 20 20 20 20 26 20 20 20 20 26 20 20 20 20 20 20 20 26 26 20 20 20 20 26 26 26 35 20 20 20 20 20 26 20 20 26 20 26 20 20 26 20 26 20 20 26 26 20 26 26 26 20 20 26 26 26 35 35 20 20 20 26 20 26 26 20 26 20 26 26 20 26 20 26 35 20 26 35 26 26 35 26 35 20 35 26 26 35 35 COOLING CAPACITY (kW) UNIT D UNIT E UNIT A UNIT B UNIT C UNIT D UNIT E 20 20 20 26 26 26 26 35 26 20 26 35 26 26 26 35 35 35 26 35 35 26 35 35 35 52 35 35 35 35 35 20 26 35 26 35 26 35 35 26 52 35 35 52 35 26 35 35 52 52 35 52 52 35 52 52 52 52 35 52 35 35 2.02 1.94 1.95 1.83 1.88 1.79 1.79 1.91 2.37 1.82 1.74 2.01 1.80 2.20 2.28 1.73 1.77 1.83 1.59 1.70 1.53 2.07 2.20 1.62 1.65 1.63 1.66 2.48 2.17 2.25 2.21 2.02 1.94 1.95 1.83 1.88 2.32 1.79 1.91 2.37 1.82 2.26 2.01 1.80 2.20 2.28 2.25 1.77 1.83 2.07 2.20 1.53 2.07 2.20 2.11 1.65 1.63 2.15 2.48 2.17 2.25 2.21 2.02 1.94 1.95 2.38 1.88 2.32 2.32 1.91 2.37 1.82 2.26 2.61 1.80 2.20 2.28 2.25 2.83 1.83 2.07 2.71 1.99 2.07 2.70 2.11 2.64 1.63 2.65 2.48 2.17 2.77 2.73 2.02 1.94 1.95 2.38 2.44 2.32 2.32 3.06 2.37 1.82 2.26 3.21 2.34 2.20 2.97 2.77 2.83 2.93 2.07 2.71 2.45 2.07 2.70 2.59 2.64 4.32 2.65 3.05 2.68 2.77 2.73 RATED POWER (kW) COMBINATIONS 5x1 20 20 20 20 20 20 26 20 20 26 20 26 20 20 26 26 20 20 26 26 26 20 26 26 26 20 20 26 35 26 35 20 20 20 20 26 20 26 26 20 26 20 26 26 20 26 26 35 20 26 26 35 26 26 35 26 35 20 26 35 35 35 20 20 26 20 26 26 26 26 35 26 20 26 35 26 26 35 35 35 35 26 35 35 26 35 35 35 52 35 35 35 35 20 26 26 35 26 35 26 35 35 26 52 35 35 52 35 35 35 52 35 52 35 52 52 35 52 52 52 52 35 52 35 2.11 2.04 2.01 1.89 2.01 1.94 1.86 1.90 1.87 1.77 1.94 1.90 1.85 1.86 1.89 1.81 1.90 1.85 1.86 1.89 1.81 1.89 1.80 2.40 2.45 2.35 2.43 2.34 2.44 2.40 2.38 2.11 2.04 2.01 1.89 2.01 1.94 1.86 1.90 1.87 1.77 1.94 1.90 1.85 1.86 1.89 1.81 2.46 2.40 2.42 2.45 2.35 2.45 2.34 2.40 2.45 2.35 2.43 2.34 2.44 2.40 2.38 2.11 2.04 2.01 1.89 2.01 1.94 1.86 1.90 1.87 1.77 2.52 2.46 2.40 2.42 3.02 2.90 2.46 2.40 2.42 2.45 2.35 3.02 2.88 2.40 2.45 2.35 2.43 2.34 3.00 2.95 2.93 2.11 2.04 2.01 1.89 2.61 2.52 2.42 3.03 3.00 4.68 2.52 2.46 2.95 2.97 3.02 2.90 2.46 2.40 2.42 3.02 2.90 3.02 2.88 2.40 2.45 2.35 2.99 2.88 3.00 2.95 2.93 2.02 2.53 3.11 2.38 3.00 2.32 2.86 3.06 2.37 4.83 2.79 3.21 4.77 2.71 2.97 2.77 2.83 4.85 4.22 2.71 4.06 4.23 2.70 4.30 4.38 4.32 4.39 3.05 4.43 2.77 2.73 2.11 2.65 3.21 5.01 2.61 3.10 4.93 3.03 4.96 4.68 2.52 3.03 2.95 4.92 3.02 4.80 2.46 2.95 4.92 3.02 4.80 3.02 4.77 2.40 3.02 4.80 2.99 4.77 3.00 2.95 2.93 INPUT POWER (kW) MIN. RAT. MAX. MIN. RAT. MAX. 4.14 4.22 4.47 4.43 4.54 4.55 4.55 4.87 4.87 4.97 4.64 5.35 5.13 4.73 5.24 4.83 4.93 5.44 4.93 4.93 4.75 5.13 5.13 5.22 5.31 5.55 5.54 5.55 5.59 5.47 5.59 10.10 10.30 10.50 10.81 11.09 11.09 11.09 11.09 11.87 12.13 12.13 12.23 12.23 12.23 12.35 12.35 12.38 12.38 12.45 12.45 12.64 12.76 12.76 12.95 13.43 13.89 13.89 13.89 13.89 13.89 14.24 12.28 12.38 12.56 12.60 12.92 12.92 12.92 12.92 12.92 13.01 13.01 13.05 13.06 13.06 13.09 13.09 13.10 13.10 13.20 13.20 13.25 13.31 13.31 13.35 13.67 13.80 13.80 13.80 13.80 13.80 14.35 1.36 1.39 1.45 1.46 1.48 1.48 1.49 1.60 1.62 1.67 1.52 1.76 1.72 1.57 1.72 1.57 1.62 1.81 1.65 1.62 1.57 1.72 1.72 1.71 1.76 1.86 1.85 1.85 1.90 1.84 1.90 3.24 3.30 3.46 3.47 3.52 3.52 3.54 3.80 3.85 3.98 3.63 4.18 4.09 3.74 4.10 3.74 3.85 4.31 3.93 3.85 3.75 4.10 4.08 4.07 4.19 4.42 4.42 4.39 4.53 4.37 4.53 3.95 4.03 4.22 4.23 4.29 4.29 4.32 4.64 4.70 4.85 4.43 5.10 4.99 4.57 5.00 4.56 4.70 5.26 4.80 4.69 4.57 5.01 4.98 4.96 5.12 5.39 5.39 5.36 5.52 5.34 5.52 HEATING CAPACITY (kW) UNIT A UNIT B UNIT C UNIT D UNIT E UNIT A UNIT B UNIT C UNIT D UNIT E 20 20 20 20 20 20 20 20 20 26 20 20 20 20 26 20 20 20 26 20 20 20 26 26 20 20 20 26 26 20 35 SUITE KEY INSTALLATIONS COMBINED SYSTEMS RATED POWER (kW) COMBINATIONS 5X1 + OUTDOOR UNIT INPUT POWER (kW) SCOP (W/W) SEER (W/W) EER (W/W) ENERGY CLASS RATED CAPACITY 5,32 - COP (W/W) MIN. RAT. MAX. MIN. RAT. MAX. RATED CAPACITY 4.44 4.54 4.73 5.28 4.73 4.80 5.43 4.94 5.70 6.16 4.80 4.94 5.04 5.89 5.38 5.97 4.94 5.04 5.89 5.38 5.97 5.63 6.16 5.04 5.38 5.97 5.58 6.16 5.83 5.97 6.16 10.46 11.06 11.66 11.46 11.74 12.03 12.47 12.76 13.05 12.82 12.62 12.90 12.92 13.20 12.94 13.08 13.35 13.34 13.77 14.04 13.90 14.16 14.43 14.28 14.54 14.96 15.23 15.54 15.54 15.47 16.19 12.31 13.01 13.71 13.48 13.81 14.15 13.86 14.18 14.50 14.24 14.02 14.02 14.05 14.35 14.06 14.07 14.36 14.35 14.35 14.63 14.47 14.75 15.03 14.87 15.15 15.42 15.70 15.70 15.70 15.63 16.35 1.15 1.18 1.24 1.44 1.24 1.26 1.48 1.32 1.57 1.71 1.24 1.30 1.35 1.62 1.46 1.65 1.29 1.34 1.62 1.44 1.65 1.53 1.70 1.36 1.43 1.65 1.51 1.67 1.59 1.65 1.72 2.89 2.96 3.11 3.60 3.11 3.15 3.70 3.30 3.92 4.29 3.09 3.25 3.38 4.05 3.65 4.12 3.22 3.35 4.05 3.60 4.12 3.82 4.25 3.40 3.58 4.12 3.78 4.18 3.99 4.13 4.30 3.52 3.61 3.79 4.39 3.79 3.84 4.52 4.03 4.79 5.23 3.78 3.96 4.12 4.95 4.46 5.02 3.93 4.09 4.95 4.39 5.02 4.66 5.18 4.15 4.37 5.02 4.61 5.10 4.86 5.04 5.24 3,42 - 3.69 3.68 3.65 3.52 3.65 3.66 3.52 3.59 3.49 3.45 3.72 3.65 3.58 3.49 3.54 3.48 3.68 3.61 3.49 3.59 3.48 3.54 3.48 3.56 3.61 3.48 3.55 3.54 3.51 3.47 3.44 3.15 3.15 3.18 3.15 3.18 3.18 3.16 3.15 3.11 3.08 3.15 3.15 3.09 3.11 3.15 3.18 3.15 3.11 3.09 3.16 3.12 3.08 3.09 3.16 3.12 3.09 3.09 3.11 3.04 3.08 3.04 B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B ENERGY CLASS COP -7 A A A B A A B B B B A A B B B B A B B B B B B B B B B B B B B 2.81 2.80 2.78 2.68 2.78 2.79 2.68 2.73 2.66 2.63 2.83 2.78 2.73 2.66 2.70 2.65 2.80 2.75 2.66 2.73 2.65 2.70 2.65 2.71 2.73 2.65 2.71 2.67 2.70 2.55 2.43 79 RESIDENTIAL INDOOR UNIT Inspiration, Innovation, Evolution RESIDENTIAL RANGE INTRODUCTION TO THE RANGE OF PRODUCTS GROUPS OF UNITS POWER RANGE COMBINED SYSTEMS KAM5-120 DN5 x1 x2 x3 20 20+20 20+20+20 20+20+20+20 26 20+26 20+20+26 20+20+20+26 35 20+35 20+20+35 20+20+20+35 52 20+52 20+20+52 20+20+26+26 26+26 20+26+26 20+20+26+35 26+35 20+26+35 20+26+26+26 26+52 20+35+35 20+26+26+35 35+35 26+26+26 26+26+26+26 35+52 26+26+35 26+26+26+35 26+35+35 80 x4 COOLING CAPACITY (kW) UNIT A UNIT B UNIT C UNIT D UNIT E UNIT A UNIT B UNIT C UNIT D UNIT E 5x1 20 20 20 20 20 20 20 20 26 20 20 20 20 26 20 20 20 20 20 20 20 26 26 20 20 20 20 26 26 26 35 20 20 20 20 20 26 20 20 26 20 26 20 20 26 20 26 20 20 26 26 20 26 26 26 20 20 26 26 26 35 35 20 20 20 26 20 26 26 20 26 20 26 26 20 26 20 26 35 20 26 35 26 26 35 26 35 20 35 26 26 35 35 20 20 20 26 26 26 26 35 26 20 26 35 26 26 26 35 35 35 26 35 35 26 35 35 35 52 35 35 35 35 35 20 26 35 26 35 26 35 35 26 52 35 35 52 35 26 35 35 52 52 35 52 52 35 52 52 52 52 35 52 35 35 2.42 2.33 2.34 2.20 2.25 2.15 2.15 2.30 2.85 2.19 2.09 2.41 2.16 2.65 2.74 2.08 2.12 2.20 1.91 2.03 1.84 2.49 2.64 1.95 1.98 1.96 1.99 2.97 2.61 2.70 2.66 COMBINATIONS 2.42 2.33 2.34 2.20 2.25 2.79 2.15 2.30 2.85 2.19 2.72 2.41 2.16 2.65 2.74 2.70 2.12 2.20 2.49 2.64 1.84 2.49 2.64 2.53 1.98 1.96 2.59 2.97 2.61 2.70 2.66 2.42 2.33 2.34 2.86 2.25 2.79 2.79 2.30 2.85 2.19 2.72 3.13 2.16 2.65 2.74 2.70 3.39 2.20 2.49 3.25 2.39 2.49 3.24 2.53 3.17 1.96 3.18 2.97 2.61 3.33 3.27 2.42 2.33 2.34 2.86 2.93 2.79 2.79 3.67 2.85 2.19 2.72 3.85 2.81 2.65 3.56 3.32 3.39 3.52 2.49 3.25 2.94 2.49 3.24 3.11 3.17 5.18 3.18 3.66 3.21 3.33 3.27 2.42 3.03 3.74 2.86 3.60 2.79 3.43 3.67 2.85 5.80 3.34 3.85 5.73 3.26 3.56 3.32 3.39 5.82 5.07 3.25 4.87 5.07 3.24 5.16 5.25 5.18 5.27 3.66 5.32 3.33 3.27 RATED CAPACITY (KW); UNIT A UNIT B UNIT C UNIT D UNIT E UNIT A UNIT B UNIT C UNIT D UNIT E 5x1 20 20 20 20 20 20 20 20 20 26 20 20 20 20 26 20 20 20 26 20 20 20 26 26 20 20 20 26 26 20 35 20 20 20 20 20 20 26 20 20 26 20 26 20 20 26 26 20 20 26 26 26 20 26 26 26 20 20 26 35 26 35 20 20 20 20 26 20 26 26 20 26 20 26 26 20 26 26 35 20 26 26 35 26 26 35 26 35 20 26 35 35 35 20 20 26 20 26 26 26 26 35 26 20 26 35 26 26 35 35 35 35 26 35 35 26 35 35 35 52 35 35 35 35 20 26 26 35 26 35 26 35 35 26 52 35 35 52 35 35 35 52 35 52 35 52 52 35 52 52 52 52 35 52 35 2.43 2.34 2.31 2.17 2.31 2.23 2.14 2.18 2.15 2.03 2.23 2.18 2.12 2.14 2.17 2.08 2.18 2.12 2.14 2.17 2.08 2.17 2.07 2.76 2.82 2.71 2.80 2.69 2.80 2.76 2.74 2.43 2.34 2.31 2.17 2.31 2.23 2.14 2.18 2.15 2.03 2.23 2.18 2.12 2.14 2.17 2.08 2.83 2.76 2.78 2.82 2.71 2.82 2.69 2.76 2.82 2.71 2.80 2.69 2.80 2.76 2.74 2.43 2.34 2.31 2.17 2.31 2.23 2.14 2.18 2.15 2.03 2.89 2.83 2.76 2.78 3.47 3.33 2.83 2.76 2.78 2.82 2.71 3.47 3.31 2.76 2.82 2.71 2.80 2.69 3.45 3.40 3.37 KEY INSTALLATIONS COMBINED SYSTEMS RATED POWER (kW) COMBINATIONS 2.43 2.34 2.31 2.17 3.00 2.89 2.78 3.49 3.45 5.38 2.89 2.83 3.40 3.42 3.47 3.33 2.83 2.76 2.78 3.47 3.33 3.47 3.31 2.76 2.82 2.71 3.44 3.31 3.45 3.40 3.37 2.43 3.05 3.70 5.76 3.00 3.56 5.67 3.49 5.71 5.38 2.89 3.49 3.40 5.66 3.47 5.52 2.83 3.40 5.66 3.47 5.52 3.47 5.48 2.76 3.47 5.52 3.44 5.48 3.45 3.40 3.37 MIN. RAT. 4.97 12.12 5.07 12.36 5.36 12.60 5.32 12.97 5.45 13.31 5.45 13.30 5.45 13.30 5.84 13.31 5.84 14.24 5.97 14.56 5.57 14.56 6.42 14.68 6.16 14.68 5.67 14.68 6.29 14.82 5.79 14.82 5.91 14.86 6.53 14.86 5.92 14.94 5.92 14.94 5.69 15.17 6.16 15.31 6.15 15.31 6.26 15.54 6.38 16.12 6.66 16.67 6.65 16.67 6.66 16.67 6.71 16.67 6.56 16.67 6.71 17.09 HEATING CAPACITY (KW) SUITE + OUTDOOR UNIT INPUT POWER (kW) MAX. MIN. RAT. 14.74 14.86 15.07 15.12 15.50 15.50 15.50 15.50 15.50 15.61 15.61 15.66 15.67 15.67 15.71 15.71 15.72 15.72 15.84 15.84 15.90 15.97 15.97 16.02 16.40 16.56 16.56 16.56 16.56 16.56 17.22 1.63 3.88 1.66 3.96 1.74 4.15 1.75 4.16 1.77 4.22 1.77 4.22 1.79 4.25 1.92 4.56 1.94 4.62 2.00 4.77 1.83 4.35 2.11 5.02 2.06 4.91 1.89 4.49 2.06 4.91 1.88 4.48 1.94 4.62 2.17 5.17 1.98 4.72 1.94 4.61 1.89 4.49 2.07 4.93 2.06 4.90 2.05 4.88 2.11 5.03 2.23 5.31 2.23 5.30 2.21 5.27 2.28 5.43 2.20 5.25 2.28 5.43 INPUT POWER (KW) EER MAX. ENERGY CLASS RATED CAPACITY 4.74 4.83 5.07 5.07 5.15 5.15 5.19 5.57 5.64 5.82 5.31 6.12 5.99 5.48 6.00 5.47 5.64 6.31 5.76 5.63 5.48 6.01 5.98 5.95 6.14 6.47 6.46 6.43 6.63 6.40 6.63 3.15 3.15 3.18 3.15 3.18 3.18 3.16 3.15 3.11 3.08 3.15 3.15 3.09 3.11 3.15 3.18 3.15 3.11 3.09 3.16 3.12 3.08 3.09 3.16 3.12 3.09 3.09 3.11 3.04 3.08 3.04 COP (W/W) MIN. RAT. MAX. MIN. RAT. MAX. RATED CAPACITY 5.10 5.22 5.43 6.07 5.43 5.52 6.25 5.68 6.56 7.08 5.52 5.68 5.80 6.78 6.19 6.86 5.68 5.80 6.78 6.19 6.86 6.47 7.08 5.80 6.19 6.86 6.42 7.08 6.70 6.86 7.08 12.03 12.72 13.40 13.17 13.50 13.83 14.34 14.68 15.01 14.74 14.51 14.83 14.86 15.18 14.88 15.05 15.35 15.34 15.84 16.15 15.98 16.29 16.59 16.42 16.72 17.20 17.51 17.87 17.87 17.80 18.61 14.15 14.96 15.77 15.50 15.89 16.27 15.94 16.31 16.68 16.38 16.12 16.12 16.15 16.50 16.17 16.18 16.51 16.50 16.50 16.82 16.65 16.97 17.29 17.10 17.42 17.74 18.05 18.05 18.05 17.98 18.80 1.33 1.36 1.43 1.66 1.43 1.45 1.70 1.52 1.81 1.97 1.42 1.49 1.55 1.87 1.68 1.89 1.48 1.54 1.87 1.66 1.89 1.76 1.95 1.56 1.65 1.89 1.74 1.92 1.83 1.90 1.98 3.32 3.40 3.57 4.14 3.57 3.62 4.26 3.80 4.51 4.93 3.56 3.73 3.89 4.66 4.20 4.74 3.70 3.85 4.66 4.14 4.74 4.39 4.89 3.91 4.12 4.74 4.34 4.80 4.58 4.75 4.94 4.05 4.15 4.36 5.05 4.36 4.41 5.20 4.63 5.51 6.01 4.34 4.55 4.74 5.69 5.12 5.78 4.52 4.70 5.69 5.05 5.78 5.36 5.96 4.77 5.02 5.78 5.30 5.86 5.59 5.80 6.03 3.69 3.68 3.65 3.52 3.65 3.66 3.52 3.59 3.49 3.45 3.72 3.65 3.58 3.49 3.54 3.48 3.68 3.61 3.49 3.59 3.48 3.54 3.48 3.56 3.61 3.48 3.55 3.54 3.51 3.47 3.44 B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B ENERGY CLASS COP -7 A A A B A A B B B B A A B B B B A B B B B B B B B B B B B B B 2.81 2.80 2.78 2.68 2.78 2.79 2.68 2.73 2.66 2.63 2.83 2.78 2.73 2.66 2.70 2.65 2.80 2.75 2.66 2.73 2.65 2.70 2.65 2.71 2.73 2.65 2.71 2.67 2.70 2.55 2.43 81 RESIDENTIAL INDOOR UNIT Inspiration, Innovation, Evolution RESIDENTIAL RANGE REFERENCES KEY INSTALLATIONS CELLER CAN ROCA RESTAURANT Location: Girona Initial situation: Units installed: Multisystem DC Inverter Capacity: 20 kW 82 INTRODUCTION TO THE RANGE OF PRODUCTS POWER RANGE GROUPS OF UNITS + COMBINED SYSTEMS SUITE OUTDOOR UNIT KEY INSTALLATIONS 83 RESIDENTIAL INDOOR UNITS Inspiration, Innovation, Evolution RESIDENTIAL RANGE POWER RANGE INTRODUCTION TO THE RANGE OF PRODUCTS GROUPS OF UNITS THE SUITE RESIDENTIAL RANGE IS PRESENT IN THE MOST COMMON PLACES. FROM APARTMENTS TO HOSPITALS, SCHOOLS AND UNIVERSITIES, THE COMFORT AND TECHNOLOGY OF THIS RANGE PROVIDES THE WELL-BEING THAT ALL HOMES NEED. VILLA BAHIA PRINCIPE RESIDENTIAL Location: Dominican Republic Initial situation: New construction Units installed: Multisystem DC Inverter Capacity: 34 kW OTHER CUSTOMERS THAT TRUSTED KAYSUN SUITE HOTELS Vera Apartment Hotel (Almeria), Sangulí Resort Salou (Tarragona) SCHOOLS AND UNIVERSITIES University of Salamanca (Salamanca), The Capuchins School (Murcia), María Maroto School (Murcia), Autism Association of Jerez (Cádiz) LEISURE CENTRES Vals Sport - Sports Centre (Malaga) 84 HOSPITAL, CLINICS AND HEALTH CENTRES Jesus Nazareno Hospital (Córdoba), Santomera Health Centre (Murcia) BUSINESS CENTRES AND OFFICES ISOLAIS Office (Seville) RESIDENCES 51 residences in Carrión (Seville), 52 residences in Torreblanca (Seville), Detached house (Palma), La Pineda Apartments (Tarragona), Puerto Mahón Apartments (Majorca), Jardines de Santa Ana Residences (Seville) + COMBINED SYSTEMS KEY INSTALLATIONS PAGÉS DEL CORRO CASTILLEJA DE LA CUESTA RESIDENTIAL RESIDENTIAL Location: Seville Initial situation: New construction Units installed: Multisystem DC Inverter Capacity: 396 kW Location: Seville Initial situation: New construction Units installed: On/Off Capacity: 112 kW TEKNON RETINE INSTITUTE UNIVERSITY OF SALAMANCA MEDICAL CENTRE SCHOOLS AND UNIVERSITIES Location: Barcelona Initial situation: Renovation Units installed: Multisystem DC Inverter Capacity: 73 kW Location: Salamanca Initial situation: Renovation Units installed: Multisystem DC Inverter Capacity: 150 kW LA ROCA 502 PROPERTY DEVELOPMENT HOTEL Location: Malaga Initial situation: New construction Units installed: Multisystem DC Inverter Capacity: 236 kW SUITE OUTDOOR UNIT RESIDENTIAL Location: Seville Initial situation: New construction Units installed: Multisystem DC Inverter Capacity: 4 MW 85 RESIDENTIAL INDOOR UNITS
Similar documents
Die BUCHSTAVIER - Das Dosierte Leben
Das Dosierte Leben Das Avant-Avantgarde-Magazin 16. Jahrgang
More informationArgo_Professional_Katalog_2011
ABCDEFG (kW/kW) mK l/h mm W.C. n° dB(A) dB(A) dB(A) dB(A) V/Ph/Hz kW kWh
More information