suite - Giorgio Gervasoni

Transcription

suite - Giorgio Gervasoni
SUITE
29
SUITE
RESIDENTIAL
Inspiration, Innovation, Evolution
INTRODUCTION TO THE
RANGE OF PRODUCTS
RESIDENTIAL RANGE
GROUPS OF UNITS
POWER RANGE
SUITE
RESIDENTIAL PRODUCT RANGE
The Kaysun RESIDENTIAL range has gone further and now offers a
wide range of units suitable for each customer. Always seeking the
well-being of the user, is at the forefront of innovation, presenting a
range that meets all market demands, respecting the environment
and guaranteeing the comfort of the client.
than 4 in SCOP for some of its models. Therefore, we not only
observe the current directives on energy efficiency, but the future
ones too.
“ELEGANCE
Kaysun units, with a balanced and harmonious aesthetic, meet
the European directive “ErP” (energy related products), offering
SCOP values between “A”, “A+” and “A++”. Our range of products
consolidates its position in the market by offering products with a
seasonal energy efficiency under heat mode that are even higher
AND COMFORT
FOR YOUR HOME”
3D TECHNOLOGY
DC INVERTER
Indoor fan motor
The 3D technology is present in the majority of the 1x1 sets and
in the multisystem combinations, which include wall-mounted,
ducts, cassettes and double flow consoles.
electricity consumption
10W
DC INVERTER
Outdoor fan motor
DC INVERTER
Compressor motor
electricity consumption
This advanced technology is reflected in the use of a DC Inverter
motor in both the compressor and fans of the indoor and outdoor
units; thus, the unit provides the user with, not only high efficiency,
but significant savings.
Thanks to the continuous technological development of the
KAYSUN 3D DC INVERTER range, it has been possible to achieve
technologically evolved equipment that, thanks to their multiple
functions, adapt to and satisfy the needs required on each moment,
thereby creating environments that are in constant balance -more
constant temperature, a high level of savings, less noise...-in order
to always provide the user with the most well-being.
The DC INVERTER compressor, stands out for the evolution of its
frequency, which has gone from 10 stages in standard equipment
to 25 stages in current KAYSUN equipment. These changes provides
a much more precise control of the power demanded, improving
energy efficiency and achieving ever-greater comfort.
equipment
CONVENTIONAL equipment
C
KAYSUN equipment
equipment
K
+*
05=,9;,9
40W
% Double rotatory
Less noise
Less vibration
Protection IPX4
Efficient ≥70%
4
6
30
7
8
9
10
5
4
25 stages
energy consumption
energie saving
temperature control
SCOP
The DC Inverter motor fans of the outdoor units gain a much more
precise control thanks to its 5 speeds, which reduces the (low)
sound pressure, and allows for greater output and energy saving
of the KAYSUN set. Likewise, the indoor unit fans now have 12
speeds, thereby adapting with precision to the demands of the
area to be climate controlled, and always placing emphasis on the
comfort, well-being and savings of the user.
3
energy consumption
energie saving
temperature control
SEER
The compressors used in the KAYSUN units not only are different
from conventional units, but all the components of the SUITE
range are fitted with features that provide the user with a high
performance.
2
10 stages
Simple rotatory
TRIPLE DC INVERTER
11
3
5
1
2
1
12
COMBINED SYSTEMS
KEY INSTALLATIONS
1W CONSUMPTION
CONDENSATION CONTROL
In relation to the European Directive ErP,
which takes into account the different
unit consumptions at partial charge and
in distinct working conditions, output
in Stand-by mode has been perfected,
arriving at a consumption of just 1W.
This represents energy savings of 80%
compared with the previous generation
of wall-mounted units on the market.
Conventional units usually consume 5W.
Wall-mounted units are equipped by
default with condensation control, which
allows us to work in cold mode under
extreme temperatures of down to -15ºC,
thus covering the demands of the areas
that require cooling even in winter time.
5W
80%
1W
SUITE
+
OUTDOOR UNIT
Likewise, the operating range of the 1x1
wall-mounted and solar units in heating
mode has increased. (AUREA units
operating range: -20 a 30ºC).
50 ºC
Outoor
temp.
temp.
exterior
-15 ºC
30 ºC
Outoor
temp.
temp.
exterior
-20 ºC
LEAK AUTO-DETECTION
SWING-LOUVRE MEMORY
The system controls the discharge temperature of the compressor.
When it is out of the adequate parameters for 4 seconds within
3 consecutive times, the unit displays the alarm code “EC”. This
function allows the equipment to operate correctly and the user to
detect any problem easily.
The unit stores the position of the louvres when it is turned off; the
unit will return to that same position when it is turned on again.
1
OUTDOOR UNIT
FASE
PHASE
2
FASE
PHASE
3
FASE
PHASE
INDOOR UNIT
15 º
Wall-mounted
KID-02 S REMOTE CONTROLLER
MEMORIZA
LA INCLINACIÓN
TILT STORING
APAGA
LA UNIDAD
UNIT
SWITCHING
OFF
SE RECOLOCA
EN TO
LOUVRES
RETURN
PRIOR
POSITION
LA
MISMA
POSICIÓN
NEW
Introducing the new control for the KAYSUN residential range.
It is standard in the AUREA range. Among the features of this
new control, we would like to emphasise its capability to read
the operation data of the AUREA units range, such as the room
temperature, pipeline temperature, discharge temperature, the
compressor's energy consumption, and so on. Besides, it allows to
change the operating parameters of mentionned units, such as
activating the Auto Restart function, changing the compensation
temperature, programming the fan's stop and so on. All these
features allow the installation engineer to adapt the unit more
easily to the spaces to be climate controlled, and make the
operation control of the unit easier during the service tasks.
We would like also to stress that this new control is fitted with
the corresponding keys to activate/deactivate the SILENCE, 8º
HEATING, FOLLOW ME and AUTO-CLEANNING modes, provided
that the indoor unit is compatible with it.
31
RESIDENTIAL
INDOOR UNITS
Inspiration, Innovation, Evolution
RESIDENTIAL RANGE
INTRODUCTION TO THE
RANGE OF PRODUCTS
GROUPS OF UNITS
POWER RANGE
KID-01 S REMOTE CONTROL
FOLLOW-ME
The standard “FOLLOW ME” function included in the wireless
controllers of the SUITE range units, allows us to enjoy greater
comfort thanks to an environmental sensor integrated into the
wireless control. Said sensor perceives the temperature of the
area where the wireless controller is located, avoiding stratification
problems when the unit is regulated by the return sensor, and fixes
a more precise and real set point for the customer.
23ºC
23ºC
23ºC
29ºC
CLIMATE CONTROL WITH FOLLOW-ME
CLIMATE CONTROL WITHOUT FOLLOW-ME
8ºC HEATING
TURBO FUNCTION
This option is highly useful for rooms that are unoccupied. It
ensures that the temperature of the room is never less than 8ºC.
When the unit detects a temperature below the minimum value
established, the unit switch on immediately. The unit will start and
stop repeatedly to keep temperature at 8ºC until the temperature
of the room increases. The user will always have a room with a
comfortable temperature in winter, even when not present.
The “TURBO” function makes the compressor work at a frequency
of 110 % and the fan of indoor unit uses its maximum speed so
as to reach the desired temperature as quickly as possible. Under
cooling mode, it will return to its previous state in 30 minutes,
while in heating mode it will remain in “TURBO” mode until a new
order is given.
AUTO CLEANING
NIGHT MODE
When in cooling mode, the unit is capable of creating humid
climates that remove foreign bodies from the system. When in
heating mode, the unit creates a dry climate that evaporates the
water accumulated in the particles being expelled thanks to the fan
mode.
The night mode function allows the set-point temperature to be
changed in order to increase comfort while we sleep. In summer,
temperature rises one degree the first hour, then another degree
in the next hour; this set point temperature will be maintained
during 5 hours before shutting off the unit. In winter, the Night
mode operates in a reverse fashion from summer, that is to say,
temperature will drop one degree each hour and this temperature
will be later maintained for 5 hours.
1
FASE
PHASE
COOLING
MODE EN FRIO
FUNCIONAMIENTO
KEEPS TEMPERATURE FOR 5 HOOURS
MANTIENE LA TEMPERATURA 5 HORAS
+1ºC
2
PHASE
FASE
+1ºC
3
PHASE
FASE
HOURS
HORAS
1
2
3
4
5
6
FUNCIONAMIENTO
EN CALOR
HEATING
MODE
-1ºC
4
FASE
PHASE
-1ºC
FUNCIONAMIENTO
FAN
ONLY MODE DEL VENTILADOR SOLO
MANTIENE
LA TEMPERATURA
KEEPS
TEMPERATURE
FOR55HORAS
HOURS
32
7
off
FAN
ONLY MODE DEL VENTILADOR SOLO
FUNCIONAMIENTO
AUREA
,97
,97
NEW
The KAYSUN residential range incorporates into its
catalogue for 2015 the new AUREA unit. This new
unit presents an improved aesthetic and innovative
technology.
~
~
~
~
~
~
~
~
~
COMBINED SYSTEMS
KEY INSTALLATIONS
,97
NEW
As a novelty for 2015, KAYSUN incorporates to its
residential range, the first unit with refrigerant gas R-32.
All the benefits and technology of the KAYSUN products
in a new unit with a different type of refrigerant.
SCOP 4.0
Very quiet, just 21 Db
WIFI integrated control (Optional - A K02 WIFI USB is
required)
Innovative aesthetic
New standard multifunction controller (KID-02 S)
3D DC Inverter
Double drainage outlet
Extra-strong support
Interactive LED display
INTELIGENT
R32
SUITE
+
OUTDOOR UNIT
~
~
~
~
~
~
SCOP 4.0
New standard multifunction controller (KID-02 S)
3D DC Inverter
Refrigerant R-32
WIFI integrated control (Optional - A K02 WIFI USB is
required)
Interactive LED display
WIFI
NEW
NEW
The “INTELIGENT” function is a feature that allows both the
controller and the indoor unit to communicate in order to collect
operation data or change the configuration parameters of the
unit.
The electronic part of the unit is fitted with an application that
allows to control the system by means of a WIFI network.
NEW MULTISYSTEM MODELS
K02 WIFI USB
NEW
Kaysun presents 3 new outdoor units for the SUITE MULTISYSTEM
range: KAM2-48 DN6, KAM2-52 DN6 and KAM3-78 DN6. These
units complete the range and replace other models of the same
range that have been removed from the catalogue.
~
NEW
This new device is used to activate
the WIFI control function in the
units of the AUREA range.
KC-01.2 R
~
The units of the SPIRIT range allow to connect a wallmounted wired controller KC-01.2R as an optional
feature.
33
RESIDENTIAL
INDOOR UNITS
Inspiration, Innovation, Evolution
RESIDENTIAL RANGE
34
INTRODUCTION TO THE
RANGE OF PRODUCTS
POWER RANGE
GROUPS OF UNITS
+
COMBINED SYSTEMS
SUITE
OUTDOOR UNIT
KEY INSTALLATIONS
UNITS
35
RESIDENTIAL
INDOOR UNITS
Inspiration, Innovation, Evolution
RESIDENTIAL RANGE
INTRODUCTION TO THE RANGE
OF PRODUCTS
GROUPS OF UNITS
POWER RANGE
SYSTEM 1x1 3D DC INVERTER
The KAYSUN 1x1 Suite family is back with newness. As always, all
combinations meet the European Directive ErP and easily adapt to
all the spaces to be climate controlled. The KAYSUN SUITE range
keeps a balanced and harmonious appearance. As we did last year,
virtually the whole range is 3D and it is consolidated in the market.
With regard to our units, we are still committed with the PREMIUM
3D high range units launched last year. The SPIRIT range keeps
its position in the market thanks to its great success, beautiful
appearance, translucent display and optional wired controller.
This year KAYSUN introduces two new ranges: In first place, the
AUREA range, a set of 3D units with a renewed appearance, very
low sound levels, translucent display and an optional built-in
WIFI control system. In second place, the R32 range, which as the
name implies, provides not only all the benefits of the KAYSUN
products, but a new refrigerant gas too. Our SOLAR 3D range is
a proof of our commitment with solar energy. We would like to
stress that all our units meet the highest SEER and SCOP values of
the market. The Kaysun Suite 1x1 range is formed by four different
units that have consolidated in the market as an option to be
considered, given their capability for adapting to the demanding
requirements of our expert customers.
MONO/MULTI COMPATIBLE
Aiming for functionality and always trying to make things easier
for our users, the Kaysun residential range offers the possibility
of using the same indoor wall-mounted units (SPIRIT, AUREA and
Stylus 3D) both in multisystem and 1x1 sets, except for the 7.1kW
units since they are not connectable.
1x1
SISTEMA
SYSTEM
OUTDOOR
UNIT
UNIDAD
EXTERIOR
In this fashion, a multisystem installation and an individual sets
installation can combine exactly the same wall-mounted units,
thereby allowing at the same time that a 1x1 units installation
could be arranged with multisystem units modifying only the
outdoor units to satisfy the changing needs of users.
INDOOR UNIT
UNIDAD INTERIOR
Mural
Wall-mounted
SILENCE
Our sets units are fitted with the "SILENCE" mode. This function
allows to reduce the sound level of indoor units to the minimum.
When this operating mode is activated, the fan automatically selects the extra-low speed, thereby reducing the sound levels of the
unit and providing a calm and relaxed environment.
DISTANCES AND HEIGHT DIFFERENCES*
26
35
52
71
TOTAL LENGTH
25
25
30
50
MAXIMUM HEIGHT
10
10
20
25
*Note: These distances correspond to the AUREA range. Verify these data for
each range.
36
+
COMBINED SYSTEMS
2.6
POWER kW
SUITE
OUTDOOR UNIT
KEY INSTALLATIONS
3.5
5.2
7.1
SPIRIT
KAY-26 DN6
KAY-35 DN6
KAY-52 DN6
KAY-71 DN6
KAY-S 26 DN5
KAY-S 35 DN5
KAY-S 52 DN5
KAY-S 71 DN5
AUREA
PREMIUM 3D
KAY-26 3DN5
R32
KAY-26 DR32
KAY-35 DR32
SOLAR 3D WALL MOUNTED
KAY-PV 35 DN5
distributed by
SOLAR 3D CASSETTE
KCI-PV 35 DN5
distributed by
SOLAR 3D DUCTS
KPD-PV 35 DNS
distributed by
37
RESIDENTIAL
INDOOR UNIT
Inspiration, Innovation, Evolution
RESIDENTIAL RANGE
SPIRIT
POWER RANGE
INTRODUCTION TO THE
RANGE OF PRODUCTS
GROUPS OF UNITS
1x1
TECHNICAL SPECIFICATIONS
MODEL SET
KAY-26 DN6
KAY-35 DN6
KAY-52 DN6
KAY-71 DN6
!"#$!& '
kW
1.3/2.64/3.22
1.41/3.42/4.29
1.90/5.13/5.90
2.18/6.45/7.10
!"#$!& '
Kcal/h
1118/2270/2769
1212/2941/3689
1634/4412/5074
1875/5547/6106
kW
0.144-1.240
0.139-1.650
0.157-2.270
0.204-2.730
S))*
5.61
5.63
6.11
5.91
#+# ,,
A+
A+
A++
A+
(
H# !"#$!& '
kW
1.01/2.78/3.45
0.98/3.66/9.54
1.27/5.27/6.22
1.60/7.3/8.64
H# !"#$!& '
Kcal/h
867/2391/2967
843/3148/3904
1092/4532/5350
1376/6304/7430
kW
0.175-1.230
0.177-1.620
0.191-2.220
0.293-3.090
3.81
3.83
3.80
3.82
A
A
A
A
S-. /" "#,'
4.81
4.82
5.11
4.84
H# #+# ,,
A++
A++
A+++
A++
2.15
2.33
3.90
4.87
2.58
2.37
2.45
2.35
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
H# (
S-.
H# #+# ,,
(warm areas)
H# 012
kW
-. 012
./#" ,(
V / F / Hz
INDOOR UNIT
KAY-26 DN6
KAY-35 DN6
KAY-52 DN6
KAY-71 DN6
A" 3/
3
m /h
650/560/450
650/560/450
750/550/480
1100/970/800
S($ "essure*
dB (A)
27
27
26
30
W$4 & H#4 & 5#4
mm
800/275/188
800/275/188
940/275/205
1045/315/235
N# /#4
Kg
7.5
7.5
9
12.5
./#" /"
mm2
From outdoor
From outdoor
From outdoor
From outdoor
( /"
mm2
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
KAE-26 DN6
KAE-35 DN6
KAE-52 DN6
KAE-71 DN6
OUTDOOR UNIT
"#,," #
-($" "flow
S($ "essure
*#R"#"
*#R"#" 4"# ! S(##"
Rotary
Rotary
Rotary
Rotary
3
m /h
1800
1800
2200
2700
dB (A)
56
56
59
60
R-410
R-410
R-410
R-410
gr
800 / 15
950 / 15
1250 / 15
1950 / 30
L6($ # $##"
mm (inch)
ø6.35 (1/4")
ø6.35 (1/4")
ø6.35 (1/4")
ø9.52 (3/8")
G, # $##"
mm (inch)
ø9.52 (3/8")
ø9.52 (3/8")
ø12.7 (1/2")
ø15.9(5/8")
M& #4 m
25
25
30
30
H#4 $7erence
m
10
10
20
20
W$4!H#4/Depth
mm
780/540/250
780/540/250
760/590/285
845/700/320
N# /#4
Kg
28
28
34.5
47
charge **
of pipes
./#" /"
mm
2
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
( /"
mm2
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
* Sound pressure in “Silence” mode / **Factory pre-charge for 5 metres of installation / Additional charge for every metre added after 5 metres
Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 30ºC (Heating)
38
R410A
SUITE
+
OUTDOOR UNIT
KEY INSTALLATIONS
COMBINED SYSTEMS
1W
GENERAL FEATURES
KAYSUN residential range keeps for 2015 the SPIRIT range wallmounted units, which were already introduced last year. They display
an elegant appearance and they are designed to keep extra-low sound
levels.
Ţ
Their white translucent smart DISPLAY provides user with
information on the equipment and alarm systems status. When
necessary, it can be turned off any time.
Ţ
Possibility to block the unit for heating-only function.
Ţ
Compatible with wired remote controller (KC-01.2 R model
recommended).
Ţ
Drain pipe connection from left or right can be selected.
Ţ
Louvres position memory.
Ţ
Automatic reset.
Ţ
Leakage detection system.
Ţ
SCOP 3.8, SCOP 4.8 and 5.1 in warm areas, depending on the
model.
Ţ
Compatible with 1x1 and multisystem sets.
Ţ
The KID-01 S wireless controller allows to query the unit's
operating data, such as sensors, compressor's frequency, alarm
history records, and so on.
Ţ
The KI-02 S optional controller allows to change configuration
parameters, such as: Auto Restart function activation/
deactivation, compensation temperature change under heating
mode, fan performance under THERMO-OFF mode, and so on.
+
+
POSSIBILITY TO BLOCK THE UNIT FOR HEATING-ONLY FUNCTION
COMPATIBLE WITH KC R-01.2 WIRED CONTROLLER
,97
KID-01 S
STANDARD
CONTROLLERS
INDIVIDUAL
KC-01.2 R
For further information, please see our Controllers range
BMS AND SOFTWARE
KC-02.1 H
K01-WIFI
39
RESIDENTIAL
INDOOR UNITS
Inspiration, Innovation, Evolution
RESIDENTIAL RANGE
AUREA
1x1
INTRODUCTION TO THE
RANGE OF PRODUCTS
POWER RANGE
GROUPS OF UNITS
NEW
TECHNICAL SPECIFICATIONS
MODEL SET
KAY-S 35 DN5
KAY-S 52 DN5
KAY- S 71 DN6
899:;<= >?@?>;BD EF;<IJO?BPQJF?TIU
kW
1.40/2.78/3.18
1.61/3.51/4.11
1.95/5.27/5.75
2.31/7.03/7.33
899:;<= >?@?>;BD EF;<IJO?BPQJF?TIU
Kcal/h
1204/2391/2735
1385/3019/3535
1677/4532/4945
1987/6046/6304
kW
0.867
1.095
1.540
2.700
XYYZ
6.51
6.43
7.40
6.11
899:;<= P<PO=D >:?[[
A++
A++
A++
A++
899:;<= ;<@VB
\P?B;<= >?@?>;BD EF;<IJO?BPQJF?TIU
kW
1.15/3.07/3.39
1.20/3.81/4.61
1.38/5.56/6.43
1.65/7.62/8.81
\P?B;<= >?@?>;BD EF;<IJO?BPQJF?TIU
Kcal/h
989/2640/2915
1032/3277/3965
1187/4782/5570
1419/6553/7577
kW
0.808
1.114
1.734
2.540
4.03
4.03
4.01
4.05
\P?B;<= P_>;P<>D >:?[[
A+
A+
A+
A+
X8]^ E`?OF ?OP?[U
5.10
5.11
5.14
4.83
A+++
A+++
A+++
A++
2.68
3.02
3.89
4.78
3.21
2.74
2.51
2.44
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
\P?B;<= ;<@VB
X8]^
\P?B;<= P<PO=D >:?[[
(warm areas)
\P?B;<= >?@?>;BD abc8
kW
8]^ abc8
^9`PO [V@@:D
V / F / Hz
INDOOR UNIT
KAY-S 26 DN5
KAY-S 35 DN5
KAY-S 52 DN5
KAY-S 71 DN5
m;O n:9`
m3/h
490/430/310
500/440/320
710/610/510
1060/860/670
X9V<Q @Oessure*
dB (A)
21
21
23
24
k;QBeJ\P;=eB/Depth
mm
770/295/198
850/300/198
1010/325/230
1130/340/240
lPB `P;=eB
Kg
7.2
8.5
11.4
13.7
^9`PO `;O;<=
mm
From outdoor
From outdoor
From outdoor
From outdoor
89FFV<;>?B;9< `;O;<=
mm2
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
OUTDOOR UNIT
KAE-S 26 DN6
KAE-S 35 DN6
KAE-S 52 DN6
KAE-S 71 DN6
89F@OP[[9O BD@P
Rotary
Rotary
Rotary
Rotary
2
]VBQ99O ?;Oflow
m3/h
1900
2000
2100
2700
X9V<Q @Oessure
dB (A)
55
55
58.5
60
R-410 A
R-410 A
R-410 A
R-410 A
gr
850 / 15
1030 / 15
1650 / 15
1950 / 30
f;gV;Q @;@P Q;?FPBPO
mm (inch)
ø6.35 (1/4")
ø6.35 (1/4")
ø6.35 (1/4")
ø9.52 (3/8")
h?[ @;@P Q;?FPBPO
mm (inch)
ø9.52 (3/8")
ø9.52 (3/8")
ø12.7 (1/2")
ø15.9(5/8")
i?TI @;@;<= :P<=Be
m
25
25
30
50
^;@P eP;=eB Q;jerence
m
10
10
20
25
k;QBeJ\P;=eB/Depth
mm
810/558/310
810/558/310
810/558/310
845/700/320
lPB `P;=eB
Kg
30
30.5
36
49.8
ZPdO;=PO?<B
ZPdO;=PO?<B >e?O=P J XV@@:PFP<B?OD
charge **
^9`PO `;O;<=
mm2
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
89FFV<;>?B;9< `;O;<=
mm
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
* Sound pressure in “Silence” mode.
2
Working temperature range: -15ºC to 50ºC (Cooling) / -20ºC to 30ºC (Heating)
**Factory pre-charge for 5 metres installations / Additional charge per added metre.
40
KAY-S 26 DN5
SUITE
+
OUTDOOR UNIT
KEY INSTALLATIONS
COMBINED SYSTEMS
50/60
Hz
R410A
1W
GENERAL FEATURES
Introducing AUREA, the new unit for the Kaysun Suite range. This
wall-mounted unit replace the former STYLUS 3D and introduces new
elements. Its 3D technology and new design will undoubtedly get your
attention.
Ţ
Possibility to block the unit for heating-only function.
Ţ
Drain pipe connection from left or right can be selected.
Ţ
Louvres position storage.
Ţ
MONO and MULTI units are compatible.
Ţ
Automatic reset.
Ţ
WIFI control and optional K02 WIFI USB connection for both local
and remote control of the unit.
Ţ
Leakage detection system.
Ţ
Ţ
INVERTER (3D) compressor and fans.
Ţ
The white translucent smart DISPLAY provides user with
information on the equipment and alarm systems status. When
necessary, it can be turned off any time. This unit also includes
the MUTE mode, which consists in turning the beeper off when it
is no longer necessary.
KID-02 S controller included. This device is able to read the
operating parameters of the unit, as well as making the
corresponding configuration adjustments in order to effectively
adapt the unit to the spaces to be climate controlled.
Ţ
SCOP 4.0, over European Directive ERP, for a high energy
efficiency. SCOP 4.8 and 5.1 in warm areas, depending on the
model.
+
+
POSSIBILITY TO BLOCK THE UNIT FOR HEATING-ONLY FUNCTION
CONTROLLED BY WIFI NETWORK (OPTIONAL)
NEW
KID-02 S
STANDARD
NEW OPTIONAL WIFI CONTROL
K02 WIFI USB ACCESSORY
,97
CONTROLLERS
For further information, please see our Controllers range
BMS AND SOFTWARE
K01-WIFI
41
RESIDENTIAL
INDOOR UNITS
Inspiration, Innovation, Evolution
RESIDENTIAL RANGE
PREMIUM 3D
INTRODUCTION TO THE
RANGE OF PRODUCTS
POWER RANGE
GROUPS OF UNITS
1x1
TECHNICAL SPECIFICATIONS
opqrs tru
KAY-26 3DN5
vwwxyz{ |}~}|y€ ‚yzƒ„…}†‡„‚}ˆƒ‰
kW
1.03/2.81/3.57
vwwxyz{ |}~}|y€ ‚yzƒ„…}†‡„‚}ˆƒ‰
Kcal/h
886/2417/3070
kW
0.77
vwwxyz{ yz~Š
‹ŒŒ
7.00
vwwxyz{ †Ž|y†z|€ |x}
A++
†}yz{ |}~}|y€ ‚yzƒ„…}†‡„‚}ˆƒ‰
kW
1.03/3.08/3.81
†}yz{ |}~}|y€ ‚yzƒ„…}†‡„‚}ˆƒ‰
Kcal/h
886/2649/3277
kW
0.78
†}yz{ yz~Š
‹v‘’
4.00
†}yz{ †Ž|y†z|€ |x}
A+
‹v‘’ “}…‚ }…†}‰
5.10
†}yz{ †z†…{€ |x}
A++
(warm areas)
†}yz{ |}~}|y€ ”•–v
2.34
kW
v‘’ ”•–v
’w“†… Š~~x€
3.05
V / F / Hz
—˜qpp™ š˜—u
220-240/1/50
KAY-26 3DN5
›y… œxw“
m3/h
620/480/370
‹wŠz‡ ~…essure*
dB (A)
20
y‡ž ˆ †y{ž ˆ Ÿ†~ž
mm
898/298/148
† “†y{ž
Kg
10
’w“†… “y…yz{
mm2
From outdoor
vw‚‚Šzy|}ywz “y…yz{
mm2
(4+T)x2.5
pšuqpp™ š˜—u
KAE-26 3DN5
vw‚~…†w… €~†
Rotary
‘Š‡ww… }y…flow
m /h
‹wŠz‡ ~…essure
dB (A)
56
†¡…y{†…}z
gr
R-410
†¡…y{†…}z |ž}…{† „ ‹Š~~x†‚†z}…€ |ž}…{† ¢¢
gr
1100 / 20
3
2000
£y¤Šy‡ ~y~† ‡y}‚††…
mm (inch)
ø6.35 (1/4")
¥} ~y~† ‡y}‚††…
mm (inch)
ø9.52 (3/8")
¦}ˆƒ ~y~yz{ x†z{ž
m
25
’y~† ž†y{ž ‡y§erence
m
10
y‡ž ˆ †y{ž ˆ Ÿ†~ž
mm
760/590/285
† “†y{ž
Kg
35
’w“†… “y…yz{
mm
(2+T)x2.5
vw‚‚Šzy|}ywz “y…yz{
mm
(4+T)x2.5
2
2
* Sound pressure in “Silence” mode / **Factory pre-charge for 5 metres installation / Additional charge for every metre added after 5 metres.
Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 30ºC (Heating)
42
50/
15
SUITE
+
OUTDOOR UNIT
KEY INSTALLATIONS
COMBINED SYSTEMS
50/60
Hz
R410A
1W
GENERAL FEATURES
In 2015, Kaysun will keep PREMIUM 3D, its high range unit. This unit
stands out among the rest for its metallic and avant-garde design and
its innovative opening.
Ţ
It includes the KID-01 S controller.
Ţ
The EYE-DETECTOR allows for the unit to turn on/off thanks to
an infrared sensor that will detect movement when somebody
enters the room.
Ţ
The most outstanding features of this unit are the automatic
reset and a leakage detection system.
Ţ
SCOP 4.0, over European Directive ERP, for a high energy
efficiency. SCOP 5.1 in warm areas.
Ţ
Possibility to block the unit for heating-only function.
+
POSSIBILITY TO BLOCK THE UNIT FOR HEATING-ONLY FUNCTION
+
EYE-DETECTOR FUNCTION INCLUDED
KID-01 S
STANDARD
,97
CONTROLLERS
INDIVIDUAL
KID-01 S
For further information, please see our Controllers range
BMS AND SOFTWARE
K01-WIFI
43
RESIDENTIAL
INDOOR UNITS
Inspiration, Innovation, Evolution
RESIDENTIAL RANGE
R-32
INTRODUCTION TO THE
RANGE OF PRODUCTS
POWER RANGE
GROUPS OF UNITS
NEW
TECHNICAL SPECIFICATIONS
¨©ª«¬ ­«®
KAY-26 DR32
KAY-35 DR32
¯°°±²³´ µ¶·¶µ²¸¹ º»²³¼½¾¶¸¿À½»¶Á¼Â
kW
1.15/2.63/3.05
1.21/3.51/4.55
¯°°±²³´ µ¶·¶µ²¸¹ º»²³¼½¾¶¸¿À½»¶Á¼Â
Kcal/h
989/2262/2623
1040/3019/3913
kW
0.860
1.080
ÄÅÅÆ
7.03
7.05
¯°°±²³´ ¿Çµ²¿³µ¹ µ±¶ÈÈ
A++
A++
¯°°±²³´ ²³·Ã¸
É¿¶¸²³´ µ¶·¶µ²¸¹ º»²³¼½¾¶¸¿À½»¶Á¼Â
kW
1.22/2.93/3.26
1.18/3.81/4.71
É¿¶¸²³´ µ¶·¶µ²¸¹ º»²³¼½¾¶¸¿À½»¶Á¼Â
Kcal/h
1049/2520/2804
1015/3277/4051
kW
0.780
1.025
4.03
4.08
É¿¶¸²³´ ¿Çµ²¿³µ¹ µ±¶ÈÈ
A+
A+
įÊË ºÌ¶¾» ¶¾¿¶ÈÂ
5.11
5.15
A+++
A+++
2.68
3.02
3.21
2.74
220-240/1/50
220-240/1/50
É¿¶¸²³´ ²³·Ã¸
įÊË
É¿¶¸²³´ ¿³¿¾´¹ µ±¶ÈÈ
(warm areas)
É¿¶¸²³´ µ¶·¶µ²¸¹ ÍÎϯ
kW
¯ÊË ÍÎϯ
Ë°Ì¿¾ È÷·±¹
V / F / Hz
ÐѪ©©Ò ÓÑЮ
KAY-26 DR32
KAY-35 DR32
Ô²¾ Õ±°Ì
3
m /h
495/420/320
525/480/335
İóÀ ·¾essure*
dB (A)
22
22
Ö²À¸× Á É¿²´×¸ Á Ø¿·¸×
mm
722/290/187
802/297/189
Ù¿¸ Ì¿²´×¸
Kg
7.2
8.1
Ë°Ì¿¾ ̲¾²³´
mm2
From outdoor
From outdoor
¯°»»Ã³²µ¶¸²°³ ̲¾²³´
mm2
(4+T)x2.5
(4+T)x2.5
©Ó®ª©©Ò ÓÑЮ
KAY-26 DR32
KAY-35 DR32
¯°»·¾¿ÈÈ°¾ ¸¹·¿
Rotary
Rotary
1800
2000
ÊøÀ°°¾ ¶²¾flow
m /h
İóÀ ·¾essure
dB (A)
3
Æ¿Ú¾²´¿¾¶³¸
53
54
R-32
R-32
Û²ÜòÀ ·²·¿ À²¶»¿¸¿¾
mm (inch)
ø6.35 (1/4")
ø6.35 (1/4")
Ý¶È ·²·¿ À²¶»¿¸¿¾
mm (inch)
ø9.52 (3/8")
ø9.52 (3/8")
Þ¶Á¼ ·²·²³´ ±¿³´¸×
m
25
25
˲·¿ ׿²´×¸ À²ßerence
m
10
10
Ö²À¸× Á É¿²´×¸ Á Ø¿·¸×
mm
770/555/300
770/555/300
Ù¿¸ Ì¿²´×¸
Kg
30
30
Ë°Ì¿¾ ̲¾²³´
mm2
(2+T)x2.5
(2+T)x2.5
¯°»»Ã³²µ¶¸²°³ ̲¾²³´
mm2
(4+T)x2.5
(4+T)x2.5
* Sound pressure in “Silence” mode.
Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 30ºC (Heating)
44
COMBINED SYSTEMS
SUITE
+
OUTDOOR UNIT
KEY INSTALLATIONS
50/60
¢*
Hz
¢*
!
1W
GENERAL FEATURES
This year KAYSUN launches its first unit charged with R-32 refrigerant
gas, as the range name suggests. With this new range, Kaysun shows
its ability to adapt to a fast-changing market.
Ţ
WIFI control and optional K02 WIFI USB connection for both local
and remote control of the unit.
Ţ
INVERTER (3D) compressor and fans.
Ţ
The white translucent smart DISPLAY provides user with
information on the equipment and alarm systems status. When
necessary, it can be turned off any time.
Ţ
Possibility to block the unit for heating-only function.
Ţ
SCOP 4.0, over European Directive ERP, for a high energy
efficiency.
Ţ
SCOP 5.1 in warm areas with the corresponding A+++ energy
efficiency label affixed.
Ţ
Louvres position storage.
Ţ
Leakage detection system.
Ţ
Possibility to activate automatic restart in the event of a power
supply failure.
Ţ
KID-02 S controller included. This device is able to read the
operating parameters of the unit, as well as making the
corresponding configuration adjustments in order to effectively
adapt the unit to the spaces to be climate controlled.
Ţ
Possibility to block the unit for heating-only function.
+
CONTROLLED BY WIFI NETWORK
NEW
NEW OPTIONAL WIFI CONTROL
K02 WIFI USB ACCESSORY
,97
KID-02 S
STANDARD
CONTROLLERS
BMS AND SOFTWARE
For further information, please see our Controllers range
ACCESSORIES
NEW
K01-WIFI
K02 WIFI USB
45
RESIDENTIAL
INDOOR UNITS
Inspiration, Innovation, Evolution
distributed by
RESIDENTIAL RANGE
INTRODUCTION TO THE
RANGE OF PRODUCTS
POWER RANGE
GROUPS OF UNITS
SOLAR ENERGY
Green energy, energy savings, conservation of the environment and
resource use, are some of the maxims that can be used to present our
most revolutionary product, the Suit Solar 3D set.
The air conditioning can function using solar energy captured during
the day, even in moments when sun is hardly present, or even at night
thanks to the optional battery.
This direct expansion air conditioning set is at the forefront of
innovation, displaying modifications that make it continue to be one
step ahead. Specially designed to function by making use of solar
energy, now we cannot just take advantage of this energy, we can store
it.
Energy savings shoot up when the battery stores the energy captured
by the photovoltaic panel, which increasingly avoids the use of grid
electricity by the unit to air-condition the room according to the final
user demands.
The appearance of the STYLUS 3D indoor unit is the same used in the
design of the SOLAR 3D wall-mounted indoor unit, therefore offering
an aesthetically plain unit that is suitable for any environment.
In addition to taking advantage of this renewable energy, the
wall-mounted set provides 6.80 and 4.00 SEER and SCOP values,
respectively, which means that it has a "A++" class in Cooling mode
and a "A+" class in Heating mode, therefore offering very high energy
efficiency values.
electric grid
SOLAR 3D DUCTS
HOW CAN ENERGY BE STORED?
electric grid
SOLAR 3D CASSETTE
HOW DOES IT WORK ?
electric grid
1
PHOTOVOLTAIC PANEL
Parallel connection
SOLAR 3D WALL-MOUNTED
Selection of
6
COMPATIBLE
INDOOR UNIT
30-40V DC
310V DC
4
46
BATTERY
Storaged energy
(optional)
Converts solar energy
200-360 VCC
5
24V DC
3
CONVERSOR
(Located in outdoor unit)
2
OUTDOOR UNIT
CHARGE CONTROLLER
Storaged energy management
(optional)
Optional system (2 et 3)
Basic system (1, 4, 5 et 6)
SUITE
+
OUTDOOR UNIT
KEY INSTALLATIONS
COMBINED SYSTEMS
GREEN ENERGY
“High efficiency enhancement by using solar panels, an
EER higher than 32.42 % and an SEER higher than 45 %”
Solar panel available
up to 250 W
* Based in the new EU energy Directive.
EER
SEER
ñìñî
ïìðñ
ëìíî
4.86
3.78
3.67
distributed by
SYSTÈMES
SYSTEMS
DC
DCInverter
inverter
3D
3DDC
DCInverter
Inverter
3D DC Inverter
3D DC Inverter
avec
panneaux
solaires
with
solar panels
ENERGY SAVING
By using more solar panels, more
energy is produced.
“An energy saving of 47.25 % is achieved by using a 3D
Inverter system with 3 solar panels ”
* Calculation based on an On/Off system.
energy (kW) / day
àáâ
energy (kW) / month
energy (kW) / year
ãäà
€
åæã
åçä
äèé
273
216
192
168
9.1
æêé
6.4
144
åêã
SYSTÈMES
SYSTEMS
ON
/ OFF
ON
/ OFF
DC Inverter
DC
inverter
3DDC
DC Inverter
3D
Inverter
avec
solaire
with1 panneau
1 solar panel
3D
3DDCDCInverter
Inverter
avec
2 panneaux
with
2 solar solaires
panels
äêà
3D
Inverter
3DDCDC
Inverter
avec
3 panneaux
with
3 solarsolaires
panels
Trustworthy tests carried out in laboratory conditions 8 hours a day, 30 days a month and 3 months a year. Information is based on normal working
conditions in a certain laboratory, while in actual use there may exist factors that vary slightly, such as sunlight, temperature and weather.
47
RESIDENTIAL
INDOOR UNITS
Inspiration, Innovation, Evolution
RESIDENTIAL RANGE
distributed by
SOLAR 3D
INTRODUCTION TO THE
RANGE OF PRODUCTS
POWER RANGE
GROUPS OF UNITS
1x1
TECHNICAL SPECIFICATIONS
MODEL SET
KAY-PV 35 DN5
KCI-PV 35 DN5
KPD-PV 35 DNS
òóóôõö÷ øùúùøõûü ýþõöÿC ùûCþùÿ
kW
1.80/3.66/4.78
1.50/3.66/4.78
1.50/3.66/4.78
òóóôõö÷ øùúùøõûü ýþõöÿC ùûCþùÿ
Kcal/h
1290/3150/4111
1290/3150/4111
1290/3150/4111
kW
1.03
1.09
1.10
S
6.80
6.10
5.60
òóóôõö÷ ö ÷ü øôù
A++
A+
A+
òóóôõö÷ õöúû
ùûõö÷ øùúùøõûü ýþõöÿC ùûCþùÿ
kW
1.08/3.81/5.03
1.08/3.81/5.03
1.08/3.81/5.03
ùûõö÷ øùúùøõûü ýþõöÿC ùûCþùÿ
Kcal/h
928/3276/4326
928/3276/4326
928/3276/4326
kW
0.87
0.95
0.97
4.02
3.82
3.81
A+
A
A
5.13
5.11
5.14
A++
A++
A++
2.78
2.78
2.78
2.91
2.91
2.91
220-240/1/50
220-240/1/50
220-240/1/50
KAY-PV 35 DN5
KCI-PV 35 DN5
KPD-PV 35 DNS
650/535/450
850
800
H
H
ùûõö÷ õöúû
H
ò
S ùûõö÷ øõöøü øôù
H
ò
ý ù þ ù ù
S ùûõö÷ ö ÷ü øôù
H
(warm areas)
ùûõö÷ øùúùøõûü ò
H
kW
ò
ò
ó
úúôü
V / F / Hz
INDOOR UNIT
õ ôó
m /h
3
A
ó ö ú essure*
dB (A)
24
39
34
mm
835/280/198
570/260/570
700/210/635
Kg
8.7
18
20
ùöô õþöõóö ýõûCõ÷ûCúû
mm
-
715/123/715
-
ùöô öû õ÷û
Kg
-
2.5
-
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(3+T)x2.5
(3+T)x2.5
(3+T)x2.5
KAE-PV 35 DN5
KAE-PV 35 DN5
KAE-PV 35 DN5
S õ û
õ÷û/Depth
W CH
û
õ÷û
N õ õö÷
mm
2
ó
òóþþöõøùûõóö õ õö÷
mm
2
OUTDOOR UNIT
òóþú ó ûüú
ûóó ùõ flow
Sóö ú essure
R õ÷ ùöû
R õ÷ ùöû øù ÷ C
Double rotary
Double rotary
Double rotary
m3/h
2000
2000
2000
dB (A)
58
58
58
R-410A
R-410A
R-410A
gr
1300 / 20
1300 / 20
1300 / 20
õ õ úõú õùþû
mm (inch)
ø6.35 (1/4")
ø6.35 (1/4")
ø6.35 (1/4")
ù úõú õùþû
mm (inch)
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ù ÿ úõúõö÷ ôö÷û
m
25
25
25
õú õ÷û õPerence
m
10
10
10
mm
810/558/310
810/558/310
810/558/310
Additional charge **
L G M õ û
õ÷û/Depth
W CH
û
õ÷û
Kg
38
38
38
õ õö÷
mm2
From indoor unit
From indoor unit
From indoor unit
òóþþöõøùûõóö õ õö÷
mm2
(3+T)x2.5
(3+T)x2.5
(3+T)x2.5
N ó
* Sound pressure in “Silence” mode.
**Factory pre-charge for 5 metres installations / Additional charge per metre added after 5 metres.
Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 30ºC (Heating)
48
SUITE
+
OUTDOOR UNIT
KEY INSTALLATIONS
COMBINED SYSTEMS
50/60
Hz
¢*
R410A
5
¢*
1W
GENERAL FEATURES
This year, the Suite range keeps its SOLAR 3D models. These sets
are able to use solar energy to air-condition any room by means of
photovoltaic solar panels, thereby obtaining a significant energy
saving.
Ţ
Management and accumulation of solar energy with optional
charge control and battery.
Ţ
SEER 6.80 and SCOP 4.00 for the wall-mounted unit, which
means a A++ class for Cooling mode and a A+ class for Heating
mode.
Ţ
SCOP 5.1 in warm areas.
Ţ
Wall-mounted white translucent smart DISPLAY provide user
with information on the equipment and alarm systems status.
When necessary, it can be turned off any time.
Ţ
Compatible with wired controller (KC-01.2 R model recommended)
Ţ
Possibility to block the unit for heating-only function.
distributed by
distributed by
distributed by
SOLAR 3D WALL-MOUNTED
,97
SOLAR 3D DUCTS
SOLAR 3D CASSETTE
,97
KID-01 S
STANDARD
,97
KI-ECO
STANDARD
CONTROLLERS
INDIVIDUAL
KC-01.2 R
KC-02.1 H
,97
,97
KI-ECO
STANDARD
For further information, please see our Controllers range
BMS AND SOFTWARE
ACCESSORIES
K01-WIFI
Load control
49
RESIDENTIAL
INDOOR UNITS
Inspiration, Innovation, Evolution
INTRODUCTION TO THE
RANGE OF PRODUCTS
RESIDENTIAL RANGE
GROUPS OF UNITS
POWER RANGE
MULTISYSTEM
TRIPLE DC INVERTER
Introducing the Suite Multisystem DC Inverter 2015 range of KAYSUN
designed to provide comfort and technology to every space. The
flexibility and versatility of all its indoor units, allows for multiple
combinations with different types of indoor units.
This range is also affected by the European Directive ERP regarding
equipments of less than 12 kW, which successfully meets it thanks to
its components.
Such a compliance is possible thanks to the fact that KAYSUN outdoor
units are always fitted with a DC Inverter compressor and fan, and
almost all our indoor units are equipped as standard with a DC Inverter
fan too. We confirm that almost all the combinations of this range
benefit from 3D technology.
These units are the solution for small spaces in which a larger scale
installation is not possible.
They allow for combinations containing up to 5 indoor units. There is
a wide variety of indoor units available: Wall-mounted (SPIRIT and
AUREA models), Cassettte ArtFlux 360º (600x600), Duct and double
flow Console, with power ranging from 2 to 5.2 kW.
DISTANCES AND HEIGHT DIFFERENCES*
TOTAL LENGTH
2X1
3X1
4X1
5X1
30
45
60
75
30
30
MAXIMUM HEIGHT
15
MAX. INDIVIDUAL LENGTH
20
25
AUREA MODEL COMPATIBLE WITH MULTI MODEL
NEW
The new Suite 1x1, AUREA unit is also available for the MULTISYSTEM
option, thereby replacing the former STYLUS 3D. The unit can be
controlled by a WIFI network by means of the corresponding optional
controller.
MONO/MULTI COMPATIBLE
Aiming for functionality and always trying to make things easier for
our users, the KAYSUN residential range offers the possibility of using
the same indoor wall-mounted units (SPIRIT and AUREA) both in
multisystem and 1x1 sets.
1x1
MULTISISTEMA
MULTISYSTEM
SISTEMA
SYSTEM
UNIDAD
EXTERIOR
OUTDOOR
UNIT
In this fashion, a multisystem installation and an individual sets
installation can combine exactly the same wall-mounted units
aesthetically, whilst allowing for a 1x1 units installationto be arranged
with multisystem units, just by modifying the outdoor units, in order to
satisfy the changing needs of users.
UNIDAD
INTERIOR
INDOOR
UNIT
UNIDAD EXTERIOR
UNIDADES
INTERIORES
INDOOR
UNITS
OUTDOOR UNIT
Mural
Wall-mounted
Wall-mounted
Mural
50
Wall-mounted
Mural
Wall-mounted
Mural
KEY INSTALLATIONS
COMBINED SYSTEMS
POWER KW
SUITE
+
OUTDOOR UNIT
2.0
2.6
3.5
5.2
INDOOR UNITS
SPIRIT
KAY-20 DMN6
AUREA
KAY-26 DN6
KAY-35 DN6
KAY-52 DN6
KAY-S 26 DN6
KAY-S 35 DN6
KAY-S 52 DN6
KSD-26 DMN6
KSD-35 DN6
KSD-52 DMN6
NEW
DOUBLE FLOW CONSOLE
CASSETTE ART FLUX 360º (600x600)
NEW
KCI-26 DMN7
KCI-35 DN9
KCI-52 DMN7
KPD-26 DMN6
KPD-35 DN9
KPD-52 DMN6
DUCTS
KPD-20 DMN6
OUTDOOR UNIT
NEW
POWER KW
NEW
4.8
5.2
KAM2-48 DN6
KAM2-52 DN6
NEW
6.2
7.8
8.0
10.5
12.0
No OF INDOOR
UNITS
2
3
4
5
KAM3-62 DN5
KAM3-78 DN6
KAM4-80 DN5
KAM4-105 DN5
KAM5-105-105 DN5
KAM5-120 DN5
51
RESIDENTIAL
INDOOR UNIT
Inspiration, Innovation, Evolution
RESIDENTIAL RANGE
SPIRIT
INTRODUCTION TO THE
RANGE OF PRODUCTS
POWER RANGE
GROUPS OF UNITS
MULTISYSTEM
TECHNICAL SPECIFICATIONS
MODEL
KAY-26 DN6
KAY-35 DN6
KAY-52 DN6
! "#$#"%&
kW
2.05
2.63
3.52
5.13
! "#$#"%&
Kcal/h
1763
2262
3027
4412
'(#%! "#$#"%&
kW
2.34
2.93
3.66
5.27
'(#%! "#$#"%&
Kcal/h
2012
2520
3148
4532
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
m³/h
620/540/440
650/560/450
650/560/450
750/550/480
dB (A)
27
27
27
26
23-1 $$( 1#4(%(+
mm (inch)
ø6.35 (1/4")
ø6.35 (1/4")
ø6.35 (1/4")
ø6.35 (1/4")
5#, $$( 1#4(%(+
mm (inch)
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø12.7 (1/2")
mm
800/275/188
800/275/188
800/275/188
940/275/205
Kg
7.3
7.5
7.5
9
From outdoor
From outdoor
From outdoor
From outdoor
(3+T)x2.5
(3+T)x2.5
(3+T)x2.5
(3+T)x2.5
)*(+ ,-$$&
.+ /*
0-1 $+
essure*
61%78'(!7%
/Depth
9(% *(!7%
)*(+ *+!
mm
44-"#% *+!
mm2
* Sound pressure in “Silence” mode.
52
KAY-20 DMN6
2
+
SUITE
OUTDOOR UNIT
KEY INSTALLATIONS
COMBINED SYSTEMS
R410A
COMPATIBLE WITH
GENERAL FEATURES
This year, the MULTISYSTEM range keeps on offering the wall-mounted
SPIRIT unit, which was introduced last year. This unit has an elegant
appearance and is designed to keep extra-low sound levels.
MULTISYSTEM OUTDOOR
UNITS
see page 65
Ţ
The white translucent smart DISPLAY provides user with information
on the equipment and alarm systems status. When necessary, it can
be turned off any time.
Ţ
Possibility to block the unit for heating-only function.
Ţ
Drain pipe connection from left or right can be selected.
Ţ
Louvres position memory.
Ţ
Compatible with 1x1 and multisystem sets.
+
COMPATIBLE WITH KC R-01.2 WIRED CONTROLLER
,97
KID-01 S
STANDARD
CONTROLLERS
INDIVIDUAL
KC-01.2 R
For further information, please see our Controllers range
BMS AND SOFTWARE
KC-02.1 H
K01-WIFI
53
RESIDENTIAL
INDOOR UNITS
Inspiration, Innovation, Evolution
RESIDENTIAL RANGE
AUREA MULTISYSTEM
POWER RANGE
INTRODUCTION TO THE
RANGE OF PRODUCTS
GROUPS OF UNITS
NEW
TECHNICAL SPECIFICATIONS
MODEL
KAY-S 35 DN6
KAY-S 52 DN6
:;;<=>? @BDB@=EF
kW
2.78
3.51
5.27
:;;<=>? @BDB@=EF
Kcal/h
2224
2808
4216
IJBE=>? @BDB@=EF
kW
3.07
3.81
5.56
IJBE=>? @BDB@=EF
Kcal/h
2640
3277
4782
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
3
m /h
490/430/310
500/440/320
710/610/510
dB (A)
21
21
23
[=\U=Z D=DJ Z=B]JEJQ
mm (inch)
ø6.35 (1/4")
6.35 (1/4)
ø6.35 (1/4")
^BT D=DJ Z=B]JEJQ
mm (inch)
ø9.52 (3/8")
ø9.52 (3/8")
ø12.7 (1/2")
mm
770/295/198
850/300/198
1010/325/230
Kg
7.2
8.5
11.4
K;OJQ O=Q=>?
mm2
From outdoor
From outdoor
From outdoor
:;]]U>=@BE=;> O=Q=>?
mm2
(3+T)x2.5
(3+T)x2.5
(3+T)x2.5
K;OJQ TUDD<F
V=Q X<;O
Y;U>Z DQ
essure*
_=ZE`aIJ=?`E
/Depth
bJE OJ=?`E
* Sound pressure in “Silence” mode.
54
KAY-S 26 DN6
SUITE
+
OUTDOOR UNIT
KEY INSTALLATIONS
COMBINED SYSTEMS
+*
05=,9;,9
05+669
R410A
GENERAL FEATURES
The new AUREA model of KAYSUN residential range for 2015, is also
fitted with an indoor unit available for the MULTISYSTEM option. This
wall-mounted unit replace the former STYLUS 3D. Its new design will
undoubtedly get your attention.
Ţ
MONO and MULTI units are compatible.
Ţ
WIFI CONTROL, ADDING OPTIONAL K02 WIFI USB connection for
both local and remote control of the unit.
Ţ
Its white translucent smart DISPLAY provides user with
information on the equipment and alarm systems status. When
necessary, it can be turned off any time. This unit also includes
the MUTE mode, which consists in turning the beeper off when it
is no longer necessary.
Ţ
Possibility to block the unit for heating-only function.
Ţ
Drain pipe connection from left or right can be selected.
Ţ
Louvres position memory and extremely low sound levels.
COMPATIBLE WITH
MULTISYSTEM OUTDOOR
UNITS
see page 65
+
+
21 DB sound pressure
CONTROLLED BY WIFI NETWORKL
(OPTIONAL)
NEW
NEW OPTIONAL WIFI CONTROL
K02 WIFI USB ACCESSORY
KID-02 S
,97
STANDARD
CONTROLLERS
BMS AND SOFTWARE
For further information, please see our Controllers range
ACCESSORIES
NEW
K01-WIFI
K02 WIFI USB
55
RESIDENTIAL
INDOOR UNIT
Inspiration, Innovation, Evolution
RESIDENTIAL RANGE
DOUBLE FLOW CONSOLE
POWER RANGE
INTRODUCTION TO THE
RANGE OF PRODUCTS
GROUPS OF UNITS
MULTISYSTEM
TECHNICAL SPECIFICATIONS
MODEL
KSD-35 DN6
KSD-52 DMN6
cddefgh ijkjiflm
kW
2.64
3.46
5.27
cddefgh ijkjiflm
Kcal/h
2270
2976
4532
nojlfgh ijkjiflm
kW
2.93
3.46
5.27
nojlfgh ijkjiflm
Kcal/h
2520
2976
4532
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
m³/h
680/580/450
550/470/360
740/650/520
dB (A)
35
35
39
yfztfx kfko xfj{olor
mm (inch)
ø6.35 (1/4")
ø6.35 (1/4")
ø6.35 (1/4")
|js kfko xfj{olor
mm (inch)
ø9.52 (3/8")
ø9.52 (3/8")
ø12.7 (1/2")
mm
700/600/210
700/600/210
700/600/210
Kg
13
15
15
pdqor qfrfgh
mm2
From outdoor
From outdoor
From outdoor
cd{{tgfijlfdg qfrfgh
mm2
(3+T)x2.5
(3+T)x2.5
(3+T)x2.5
pdqor stkkem
ufr vedq
wdtgx kr
essure*
}fxl~nofh~l
/Depth
€ol qofh~l
*Sound pressure data al low speed.
56
KSD-26 DMN6
SUITE
+
OUTDOOR UNIT
KEY INSTALLATIONS
COMBINED SYSTEMS
+*
05=,9;,9
05+669
R410A
COMPATIBLE WITH
GENERAL FEATURES
The double flow console has an elegant and compact design that
allows for the adaptation thereof to any area to be air-conditioned.
It is fitted with the latest technological features, thereby providing
users with a high comfort level.
Ţ
Its 5 speeds DC Inverter fan reduces the unit's sound levels
significantly.
Ţ
Double air intake (upper and lower intake, or just upper intake)
and 4-way air intake.
Ţ
Contacts free from ON/OFF voltage and alarm.
Ţ
Easy installation.
Ţ
Optional wired controller.
MULTISYSTEM OUTDOOR
UNITS
see page 65
+
DOUBLE AIR INTAKE
NEW
,97
KI-02 S
(*) RECOMMENDED
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER
YOUR
If you want a different controller, you shall add to the price the price difference between the SELECT
CHOOSE YOUR
CONTROLLER
‚ƒ„…‚†
recommended controller and the controller you choose.
CONTROLLERS
For further information, please see our Controllers range
INDIVIDUAL
CENTRALIZED
NEW
NEW
KCT-02.1 SR
KC-02.1 H
KC-02 SPS
KI-02 S
KCCT-64 I
KCC-64 I-PS
KCC-16
KCC-64 WEB
BMS AND SOFTWARE
K01-LON
K01-MODBUS
K01-BACNET
KAYNET CONTROL
K01-KNX
K01-WIFI
57
RESIDENTIAL
INDOOR UNIT
Inspiration, Innovation, Evolution
RESIDENTIAL RANGE
POWER RANGE
CASSETTE ART FLUX 360º
MULTISYSTEM
INTRODUCTION TO THE
RANGE OF PRODUCTS
GROUPS OF UNITS
TECHNICAL SPECIFICATIONS
MODEL
KCI-35 DN9
KCI-52 DMN7
‡ˆˆ‰Š‹Œ ŽŽŠ‘
kW
2.63
3.46
5.27
‡ˆˆ‰Š‹Œ ŽŽŠ‘
Kcal/h
2262
2976
4532
’“ŽŠ‹Œ ŽŽŠ‘
kW
2.93
4.04
5.27
’“ŽŠ‹Œ ŽŽŠ‘
Kcal/h
2520
3474
4532
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
3
m /h
680/580/520
650/530/450
800/710/560
dB (A)
36
34
39
Šž˜Šœ Š“ œŠŽŸ““–
mm (inch)
ø6.35 (1/4")
ø6.35 (1/4")
ø6.35 (1/4")
Ž— Š“ œŠŽŸ““–
mm (inch)
ø9.52 (3/8")
ø9.52 (3/8")
ø12.7 (1/2")
mm
570/260/570
570/260/570
570/260/570
Kg
16
16
18
mm
647/50/647
647/50/647
647/50/647
Kg
2.5
2.5
2.5
”ˆ•“– •Š–Š‹Œ
mm2
From outdoor
From outdoor
From outdoor
‡ˆŸŸ˜‹ŠŽŠˆ‹ •Š–Š‹Œ
mm2
(3+T)x2.5
(3+T)x2.5
(3+T)x2.5
”ˆ•“– —˜‰‘
™Š– š‰ˆ•
›ˆ˜‹œ –
essure*
¡Šœ¢£’“ŠŒ¢
/Depth
¤“ •“ŠŒ¢
”Ž‹“‰ •Šœ¢£¢“ŠŒ¢£œ“¢
”Ž‹“‰ ‹“ •“ŠŒ¢
*Sound pressure data at low speed.
58
KCI-26 DMN7
COMBINED SYSTEMS
SUITE
+
OUTDOOR UNIT
KEY INSTALLATIONS
+*
05=,9;,9
05+669
GENERAL FEATURES
The Cassette Artflux 360º 600x600 units stand out from other units
thanks to its elegant design. Their small dimensions allows them for
adapting to false ceiling installations and their 360º air flow provides
user with highest comfort and covers every corner of the room.
Ţ
The Cassette 600x600 type units supply 10 % to 15 % of outdoor
air flow directly to the unit return system.
Ţ
They are fitted with an up to 500 mm high standard condensate
pump.
Ţ
The right and left sides of these units' body are designed to
connect the necessary piping to air-condition an adjacent room.
Ţ
The electric box is located at the lower side of the unit to get a
more compact size and embed the unit easily in the ceiling.
Ţ
ON/OFF AND ALARM voltage-free contacts.
Ţ
Although the 2015 units seem to have the same design, the
main body is fitted with a new air channel and a bigger cylinder,
making these units 3 db quieter that preceding models.
COMPATIBLE WITH
+
OUTDOOR AIR SUPPLY (10-15%)
MULTISYSTEM OUTDOOR
UNITS
+
see page 65
500 mm CONDENSATE PUMP
NEW
,97
KI-02 S
(*) RECOMMENDED
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER
If you want a different controller, you shall add to the price the price difference between the
recommended controller and the controller you choose.
CONTROLLERS
SELECT
YOUR
CHOOSE YOUR
CONTROLLER
¥¦§¨©¦ª
For further information, please see our Controllers range
INDIVIDUAL
CENTRALIZED
NEW
NEW
KCT-02.1 SR
KC-02.1 H
KC-02 SPS
KI-02 S
KCCT-64 I
KCC-64 I-PS
KCC-16
KCC-64 WEB
BMS AND SOFTWARE
K01-LON
K01-MODBUS
K01-BACNET
KAYNET CONTROL
K01-KNX
K01-WIFI
59
RESIDENTIAL
INDOOR UNIT
Inspiration, Innovation, Evolution
RESIDENTIAL RANGE
DUCTS
POWER RANGE
INTRODUCTION TO THE
RANGE OF PRODUCTS
GROUPS OF UNITS
MULTISYSTEM
TECHNICAL SPECIFICATIONS
MODEL
KPD-26 DMN6
KPD-35 DN9
KPD-52 DMN6
«¬¬­®¯° ±²³²±®´µ
kW
2.05
2.63
3.5
5.27
«¬¬­®¯° ±²³²±®´µ
Kcal/h
1763
2262
3010
4532
¶·²´®¯° ±²³²±®´µ
kW
2.34
2.93
3.5
5.86
¶·²´®¯° ±²³²±®´µ
Kcal/h
2012
2520
3010
5040
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
m3/h
720/600/540
720/600/540
640/550/470
1400/1100/1000
Pa
40
40
45
70
dB (A)
34
34
35
40
Á®Â¼®À ³®³· À®²Ã·´·º
mm (inch)
ø6.35 (1/4")
ø6.35 (1/4")
ø6.35 (1/4")
ø6.35 (1/4")
IJ» ³®³· À®²Ã·´·º
mm (inch)
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø12.7 (1/2")
mm
700/210/635
700/210/635
700/210/635
920/210/635
Kg
19.5
19.5
18
¸¬¹·º »¼³³­µ
½®º ¾­¬¹
¿´²´®± ¸º·»»¼º·
(high speed)
¿¬¼¯À ³º
essure*
Å®À´ÆǶ·®°Æ´
/Depth
È·´ ¹·®°Æ´
33 23
¸¬¹·º ¹®º®¯°
mm2
From outdoor
From outdoor
From outdoor
From outdoor
«¬Ãü¯®±²´®¬¯ ¹®º®¯°
mm
(3+T)x2.5
(3+T)x2.5
(3+T)x2.5
(3+T)x2.5
*Sound pressure data at low speed.
60
KPD-20 DMN6
2
COMBINED SYSTEMS
SUITE
+
OUTDOOR UNIT
KEY INSTALLATIONS
+*
05=,9;,9
05+669
GENERAL FEATURES
Ţ
The inclined position of the KAYSUN Ducts units provides them
with a slim design. This feature allows for installing Ducts units
in areas where the false ceiling is too narrow.
Ţ
The electric box of Duct type indoor units is removable up to 1
metre.
Ţ
ON/OFF AND ALARM voltage-free contacts
Ţ
The filter is easy to remove even when piping is done.
Ţ
Standard condensation pump.
Ţ
All units include an air inlet/outlet pre-installation to facilitate
the fitting of the tubes that guarantee air circulation.
Ţ
Possibility for double air intake (rear or lower intake) that can be
easily arranged.
Ţ
Outdoor air intake to treat air with indoor unit's battery and blow
it into the room through the air line.
+
+
COMPATIBLE WITH
MULTISYSTEM OUTDOOR
UNITS
see page 65
750mm CONDENSATION PUMP
OUTDOOR AIR INTAKE
Compatible with
KC-02 SPS
,97
(*) RECOMMENDED
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER
If you want a different controller, you shall add to the price the price difference between the SELECT
YOUR
CHOOSE YOUR
recommended controller and the controller you choose. CONTROLLER
ÉÊËÌÍÊÎ
CONTROLLERS
For further information, please see our Controllers range
INDIVIDUAL
CENTRALIZED
NEW
KCT-02.1 SR
KC-02.1 H
KC-02 SPS
NEW
KCCT-64 I
KCC-64 I-PS
KCC-16
KCC-64 WEB
KI-02 S
BMS AND SOFTWARE
K01-LON
K01-MODBUS
K01-BACNET
KAYNET CONTROL
K01-WIFI
K01-KNX
RE
SU
ES
R
P HS
IC
P
AT GRA 61
ST
RESIDENTIAL
INDOOR UNIT
Inspiration, Innovation, Evolution
RESIDENTIAL RANGE
DUCTS
INTRODUCTION TO THE
RANGE OF PRODUCTS
POWER RANGE
STATIC PRESSURE GRAPHS
Air flow (m3/h)
External static pressure (Pa)
KPD 52 DMN6
Air flow (m3/h)
62
KPD-26 DMN6
External static pressure (Pa)
External static pressure (Pa)
KPD 20 DMN6
Air flow (m3/h)
GROUPS OF UNITS
+
COMBINED SYSTEMS
SUITE
OUTDOOR UNIT
KEY INSTALLATIONS
KPD-35 DN9
Medium
External static pressure (Pa)
External static pressure (Pa)
High
Air flow (m3/h)
Air flow (m3/h)
External static pressure (Pa)
Low
Air flow (m3/h)
63
RESIDENTIAL
INDOOR UNIT
Inspiration, Innovation, Evolution
RESIDENTIAL RANGE
OUTDOOR UNIT
MULTIPLE OPTIONS
INTRODUCTION TO THE
RANGE OF PRODUCTS
POWER RANGE
GROUPS OF UNITS
MULTISYSTEM
NEW
The SUITE MULTISYSTEM outdoor unit, allows arranging
installations with multiple compatible indoor units. This year we
broad the indoor units range with the introduction of the AUREA
model, a wall-mounted unit that is extremely quiet. As an option,
this unit can be locally or remotely controlled
through a WIFI network by means of a small controller that is
sold separately. The MULTISYSTEM units provide user with a high
comfort level by means of its multiple systems and the built-in DC
INVERTER compressor and fan, which also allows a very accurate
and balanced adjustments.
MULTISYSTEM
COMBINABLE
NEW
NEW
NEW
COMBINABLE
COMBINABLE
COMBINABLE
Compatible with
64
Compatible with
Compatible with
+
SUITE
OUTDOOR UNIT
KEY INSTALLATIONS
COMBINED SYSTEMS
+*
05=,9;,9
+*
05=,9;,9
+*
05=,9;,9
6<;+669
<50;
R410A
GENERAL FEATURES
Ţ
All units are equipped with a single fan.
Ţ
Outdoor units have as many expansion valves as number of
indoor units allowed.
Ţ
Capacity range from 4.8 kW to 12 kW and, depending on power,
up to 5 indoor units can be combined.
Ţ
Versatility in cooling distances, with the potential to go as far as
75 meters depending on the model.
+
1
n
VALVES AS n INDOOR UNITS
FAN
,97
L
ICA
HN RES
C
TE ATU 65
FE
RESIDENTIAL
INDOOR UNIT
Inspiration, Innovation, Evolution
RESIDENTIAL RANGE
OUTDOOR UNIT
INTRODUCTION TO THE
RANGE OF PRODUCTS
POWER RANGE
GROUPS OF UNITS
MULTISYSTEM
TECHNICAL SPECIFICATIONS
MODEL
KAM2-48 DN6
KAM2-52 DN6
KAM3-62 DN5
KAM3-78 DN6
ÏÐÐÑÒÓÔ ÕÖ×ÖÕÒØÙ
kW
4.68
5.24
6.15
7.62
ÏÐÐÑÒÓÔ ÕÖ×ÖÕÒØÙ
Kcal/h
4024.8
4506.4
5289
6553.2
ÏÐÐÑÒÓÔ ÒÓ×ÚØ
kW
1.35
1.65
1.91
2.4
ÛÜÖØÒÓÔ ÕÖ×ÖÕÒØÙ
kW
5.2
5.9
6.7
7.9
ÛÜÖØÒÓÔ ÕÖ×ÖÕÒØÙ
Kcal/h
4429
5040
5796
6803
kW
1.42
1.37
1.75
1.81
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
Rotary
Rotary
Double rotary
Double rotary
ÛÜÖØÒÓÔ ÒÓ×ÚØ
ÝÐÞÜß
supply
ÏÐà×ßÜááÐß ØÙ×Ü
flow
m3/h
2100
2100
2700
2700
essure
dB (A)
56
56
59
58
R-410
R-410
R-410
R-410
gr
1700
2000
2100
2100
m
10
10
15
15
øîùæîè éîéì èîðõìñìê
mm (Inch)
ø6.35 (1/4")
ø6.35 (1/4")
ø6.35 (1/4")
ø6.35 (1/4")
úðö éîéì èîðõìñìê
mm (Inch)
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
m
30
30
45
45
m
20
20
25
25
m
15
15
15
15
m
10
10
10
10
mm
810/558/310
810/558/310
845/700/320
845/700/320
Kg
35
37
50
50
2
2
3
3
mm2
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x4
mm2
(3+T)x2.5
(3+T)x2.5
(3+T)x2.5
(3+T)x2.5
âÚØãÐÐß ÖÒß
äåæçè éê
ëìíêîïìêðçñ
ëìíêîïìêðçñ
pre charge*
òêì óôðêïì õìñêìö÷
òîéîçï õð
x. length
x.
length (1 indoor)
ûìîïôñ èîüerence
between indoor and
outdoor units
ûìîïôñ èîüerence
between indoor units
òîéîçï õð
ýîèñôþûìîïôñ
/Depth
ÿìñ
Nìîïôñ
Mð
îõæõ ðõåæçñ åí
indoor units
òåNìê
wiring
Cåõõæçîóðñîåç
wiring
Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)
*To calculate the additional charge necessary for these units, we applied the following formula:
ADDITIONAL (GR) = (TOTAL LENGTH OF ALL CIRCUITS' LIQUID LINE - FACTORY PRE-CHARGE METRES) x 15 Grams.
Note: Standard performance data; definitive performance data depend on the indoor units combination.
66
+
COMBINED SYSTEMS
SUITE
OUTDOOR UNIT
KEY INSTALLATIONS
KAM4-80 DN5
KAM4-105 DN5
KAM5-105-105 DN5
KAM5-120 DN5
8.2
10.55
10.55
1
7052
9073
9073
155.4
2.47
3.28
3.28
3
9.1
12.0
12.3
1
7809
10329
10587
131
2.44
3.33
3.4
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
Double rotary
Double rotary
Double rotary
Double rotary
3800
5500
5500
61
64
65
R-410
R-410
R-410
R-410
2400
2700
3000
20
20
25
ø6.35 (1/4")
ø6.35 (1/4")
ø6.35 (1/4")
ø5 (1/4")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø 9
60
60
75
3
30
30
30
15
15
15
1
10
10
10
1
895/860/315
990/965/345
990/965/345
65
78
80
4
4
5
(2+T)x4
(2+T)x6
(2+T)x6
9(
(3+T)x2.5
(3+T)x2.5
(3+T)x2.5
9(
ED
N
B I MS
M E
C O YST 67
S
RESIDENTIAL
INDOOR UNIT
Inspiration, Innovation, Evolution
INTRODUCTION TO THE
RANGE OF PRODUCTS
RESIDENTIAL RANGE
COMBINED SYSTEMS
KAM2-48 DN6
x1
x2
20
20+20
26
20+26
35
20+35
52
20+52
26+26
26+35
KAM2-52 DN6
x1
x2
20
20+20
26
20+26
35
20+35
52
20+52
26+26
26+35
26+52
35+35
68
POWER RANGE
GROUPS OF UNITS
UNIT A
UNIT B
UNIT A
RATED
MAXIMUM
MINIMUM
RATED
MAXIMUM
SUITE
EER
(W/W)
ENERGY
CLASS
RATED CAPACITY
20
2.20
2.20
2.22
4.40
4.53
0.61
1.46
1.71
5,61
2.87
B
26
2.07
2.68
2.39
4.75
4.89
0.65
1.54
1.78
-
2.93
B
20
35
1.98
3.17
2.60
5.15
5.30
0.67
1.58
1.86
-
3.09
A
20
52
1.51
4.00
2.78
5.51
5.67
0.72
1.71
1.98
-
3.06
A
26
26
2.60
2.60
2.62
5.20
5.39
0.68
1.62
1.87
-
3.05
A
26
35
2.42
2.98
2.72
5.40
5.55
0.70
1.66
1.92
-
3.09
A
RATED
POWER (kW)
UNIT A
UNIT B
UNIT A
UNIT B
HEATING
CAPACITY (kW)
MINIMUM
RATED
INPUT
POWER (kW)
MAXIMUM MINIMUM
RATED
SCOP
(W/W)
MAXIMUM
COP
(W/W)
ENERGY
CLASS
COP -7
2.24
RATED CAPACITY
20
20
2.40
2.40
2.42
4.80
4.94
0.62
1.48
1.74
3,80
3.08
C
20
26
2.24
2.91
2.60
5.15
5.30
0.67
1.60
1.85
-
3.06
C
2.23
20
35
2.33
3.72
3.05
6.05
6.22
0.70
1.68
1.94
-
3.43
A
2.49
20
52
1.78
4.70
3.27
6.48
6.66
0.75
1.78
2.02
-
3.46
A
2.52
26
26
3.05
3.05
3.07
6.10
6.27
0.70
1.67
1.93
-
3.47
A
2.52
26
35
2.82
3.46
3.17
6.28
6.46
0.73
1.73
1.98
-
3.45
A
2.51
RATED
POWER (kW)
UNIT A
UNIT B
UNIT A
COOLING
CAPACITY (kW)
UNIT B
MINIMUM
RATED
INPUT
POWER (kW)
MAXIMUM MINIMUM
RATED
SEER
(W/W)
MAXIMUM
EER
(W/W)
ENERGY
CLASS
RATED CAPACITY
20
20
2.20
2.20
1.85
4.40
5.32
0.58
1.46
1.82
-
3.02
B
20
26
2.07
2.68
2.00
4.75
5.75
0.62
1.54
1.90
-
3.08
B
A
20
35
1.98
3.17
2.16
5.15
6.23
0.63
1.58
1.98
-
3.25
20
52
1.51
4.00
2.31
5.51
6.67
0.68
1.71
2.10
-
3.22
A
26
26
2.60
2.60
2.18
5.20
6.34
0.65
1.62
1.99
5,63
3.21
A
26
35
2.42
2.98
2.27
5.40
6.53
0.66
1.66
2.04
-
3.25
A
35
35
2.73
2.73
2.29
5.46
6.61
0.67
1.67
2.06
-
3.26
A
35
35
3.30
3.30
4.62
6.60
6.70
1.100
2.050
2.094
-
3.22
A
COMBINATIONS
1x2
MINIMUM
SEER
(W/W)
20
COMBINATIONS
1x2
UNIT B
INPUT
POWER (kW)
20
COMBINATIONS
1x2
KEY INSTALLATIONS
COMBINED SYSTEMS
COOLING
CAPACITY (kW)
RATED
POWER (kW)
COMBINATIONS
1x2
+
OUTDOOR UNIT
RATED
POWER (kW)
HEATING
CAPACITY (kW)
INPUT
POWER (kW)
UNIT A
UNIT B
UNIT A
UNIT B
MINIMUM
RATED
MAXIMUM MINIMUM
20
20
2.40
2.40
2.02
4.80
5.81
20
26
2.24
2.91
2.16
5.15
6.23
20
35
2.33
3.72
2.54
6.05
7.32
SCOP
(W/W)
COP
(W/W)
ENERGY
CLASS
COP -7
2.24
RATED
MAXIMUM
RATED CAPACITY
0.59
1.48
1.85
-
3.24
C
0.64
1.60
1.97
-
3.22
C
2.23
0.67
1.68
2.06
-
3.61
A
2.49
20
52
1.78
4.70
2.72
6.48
7.84
0.71
1.78
2.15
-
3.64
A
2.52
26
26
3.05
3.05
2.56
6.10
7.38
0.67
1.67
2.06
3,82
3.65
A
2.52
26
35
2.82
3.46
2.64
6.28
7.60
0.69
1.73
2.11
-
3.63
A
2.51
35
35
3.21
3.21
2.70
6.42
7.77
0.71
1.77
2.14
-
3.63
A
2.51
69
RESIDENTIAL
INDOOR UNIT
Inspiration, Innovation, Evolution
INTRODUCTION TO THE
RANGE OF PRODUCTS
RESIDENTIAL RANGE
POWER RANGE
COMBINED SYSTEMS
KAM3-62 DN5
x1
x2
x3
20
20+20
20+20+20
26
20+26
20+20+26
35
20+35
20+20+35
52
20+52
20+26+26
26+26
20+26+35
26+35
26+26+26
26+52
26+26+35
35+35
70
GROUPS OF UNITS
RATED
POWER (kW)
COMBINATIONS
UNIT A
UNIT B UNIT C
UNIT A
UNIT B
KEY INSTALLATIONS
COMBINED SYSTEMS
COOLING
CAPACITY (kW)
UNIT C
MINIMUM
RATED
SUITE
+
OUTDOOR UNIT
INPUT
POWER (kW)
MAXIMUM MINIMUM
SEER
(W/W)
RATED
MAXIMUM
EER
(W/W)
ENERGY
CLASS
RATED CAPACITY
20
20
20
2.05
2.05
2.05
2.58
6.15
7.44
0.76
1.91
2.54
5,42
3.22
A
20
20
26
1.93
1.93
2.51
2.68
6.38
7.72
0.79
1.98
2.64
-
3.22
A
20
20
35
1.84
1.84
2.94
2.78
6.62
8.01
0.82
2.05
2.73
-
3.23
A
20
26
26
1.84
2.39
2.39
2.78
6.62
8.01
0.82
2.05
2.73
-
3.23
A
20
26
35
1.78
2.32
2.85
2.92
6.95
8.41
0.86
2.15
2.86
-
3.23
A
26
26
26
2.32
2.32
2.32
2.92
6.95
8.41
0.86
2.15
2.86
-
3.23
A
26
26
35
2.28
2.28
2.81
3.10
7.38
8.93
0.91
2.28
3.03
-
3.24
A
SCOP
(W/W)
COP
(W/W)
ENERGY
CLASS
COP -7
1x3
RATED
POWER (kW)
COMBINATIONS
UNIT A
UNIT B UNIT C
UNIT A
HEATING
CAPACITY (kW)
UNIT B UNIT C
MINIMUM
INPUT
POWER (kW)
RATED MAXIMUM MINIMUM RATED
MAXIMUM
RATED CAPACITY
20
20
20
2.25
2.25
2.25
2.83
6.74
8.16
0.74
1.86
2.51
3,83
3.62
A
2.78
20
20
26
2.05
2.05
2.67
2.85
6.78
8.20
0.75
1.87
2.53
-
3.62
A
2.78
20
20
35
1.95
1.95
3.12
2.95
7.02
8.49
0.77
1.93
2.61
-
3.63
A
2.79
20
26
26
1.95
2.54
2.54
2.95
7.02
8.49
0.77
1.93
2.61
-
3.63
A
2.79
20
26
35
1.89
2.45
3.02
3.09
7.36
8.91
0.81
2.03
2.74
-
3.63
A
2.79
26
26
26
2.45
2.45
2.45
3.09
7.36
8.91
0.81
2.03
2.74
-
3.63
A
2.78
26
26
35
2.38
2.38
2.93
3.23
7.70
9.32
0.85
2.12
2.86
-
3.64
A
2.79
1x3
71
RESIDENTIAL
INDOOR UNIT
Inspiration, Innovation, Evolution
INTRODUCTION TO THE
RANGE OF PRODUCTS
RESIDENTIAL RANGE
POWER RANGE
COMBINED SYSTEMS
KAM3-78 DN6
x1
x2
x3
20
20+20
20+20+20
26
20+26
20+20+26
35
20+35
20+20+35
52
20+52
20+20+52
26+26
20+26+26
26+35
20+26+35
26+52
20+35+35
35+35
26+26+26
35+52
26+26+35
26+35+35
72
GROUPS OF UNITS
RATED
POWER (kW)
COMBINATIONS
UNIT A
UNIT B UNIT C
20
1x3
UNIT A
UNIT B
UNIT C
20
2.20
2.20
2.20
SUITE
KEY INSTALLATIONS
COMBINED SYSTEMS
COOLING
CAPACITY (kW)
20
INPUT
POWER (kW)
SEER
(W/W)
MINIMUM
RATED
MAXIMUM
MINIMUM
RATED
MAXIMUM
3.05
6.60
7.59
0.99
2.14
2.61
EER
(W/W)
ENERGY
CLASS
RATED CAPACITY
-
3.23
B
20
20
26
2.04
2.04
2.65
3.10
6.72
7.72
1.00
2.17
2.64
-
3.26
B
20
20
35
2.07
2.07
3.31
3.44
7.45
8.56
1.07
2.32
2.82
-
3.37
A
20
20
52
1.76
1.76
4.66
3.78
8.18
9.40
1.15
2.50
2.92
-
3.43
A
20
26
26
2.07
2.69
2.69
3.44
7.45
8.56
1.07
2.32
2.76
-
3.37
A
20
26
35
2.00
2.60
3.20
3.60
7.80
8.97
1.10
2.39
2.84
-
3.42
A
20
35
35
1.93
3.09
3.09
3.74
8.10
9.31
1.14
2.48
2.90
-
3.42
A
26
26
26
2.60
2.60
2.60
3.60
7.80
8.97
1.10
2.40
2.85
5,62
3.41
A
26
26
35
2.51
2.51
3.09
3.74
8.10
9.31
1.14
2.48
2.90
-
3.42
A
26
35
35
2.35
2.90
2.90
3.77
8.15
9.37
1.16
2.52
2.96
-
3.40
A
RATED
POWER (kW)
COMBINATIONS
UNIT A
20
1x3
+
OUTDOOR UNIT
UNIT B UNIT C
UNIT A
UNIT B
20
20
2.37
2.37
HEATING
CAPACITY (kW)
UNIT C
2.37
MINIMUM
RATED
3.28
7.10
INPUT
POWER (kW)
MAXIMUM MINIMUM
7.73
0.99
SCOP
(W/W)
RATED
MAXIMUM
2.07
2.91
COP
(W/W)
ENERGY
CLASS
COP
-7
B
2.69
RATED CAPACITY
-
3.60
20
20
26
2.27
2.27
2.95
3.47
7.50
8.17
1.05
2.19
3.09
-
3.59
B
2.69
20
20
35
2.31
2.31
3.69
3.83
8.30
9.04
1.13
2.36
3.24
-
3.70
B
2.69
20
20
52
1.96
1.96
5.19
4.20
9.10
10.48
1.21
2.52
3.38
-
3.79
A
2.69
20
26
26
2.31
3.00
3.00
3.83
8.30
9.04
1.13
2.36
3.24
-
3.70
B
2.69
20
26
35
2.24
2.92
3.59
4.04
8.75
9.53
1.17
2.43
3.34
-
3.78
A
2.69
20
35
35
2.15
3.45
3.45
4.18
9.05
9.86
1.20
2.49
3.37
-
3.81
A
2.69
26
26
26
2.92
2.92
2.92
4.04
8.75
9.53
1.16
2.42
3.32
3,84
3.80
A
2.69
26
26
35
2.80
2.80
3.45
4.18
9.05
9.86
1.20
2.49
3.37
-
3.81
A
2.70
26
35
35
2.63
3.24
3.24
4.20
9.10
9.91
1.20
2.49
3.37
-
3.83
A
2.70
73
RESIDENTIAL
INDOOR UNIT
Inspiration, Innovation, Evolution
INTRODUCTION TO THE
RANGE OF PRODUCTS
RESIDENTIAL RANGE
POWER RANGE
GROUPS OF UNITS
COMBINED SYSTEMS
KAM4-80 DN5
x1
x2
x3
x4
20
20+20
20+20+20
20+20+20+20
26
20+26
20+20+26
20+20+20+26
35
20+35
20+20+35
20+20+20+35
52
20+52
20+20+52
20+20+20+52
26+26
20+26+26
20+20+26+26
26+35
20+26+35
20+20+26+35
26+52
20+26+52
20+20+35+35
35+35
20+35+35
20+26+26+26
35+52
20+35+52
20+26+26+35
52+52
26+26+26
20+26+35+35
26+26+35
26+26+26+26
26+26+52
26+26+26+35
26+35+35
26+35+52
35+35+35
74
COMBINATIONS
RATED CAPACITY (KW);
COMBINED SYSTEMS
KEY INSTALLATIONS
COOLING
CAPACITY (KW)
INPUT
POWER (KW)
SUITE
+
OUTDOOR UNIT
SEER
(W/W)
EER
(W/W)
ENERGY CLASS
UNIT
A
UNIT
B
UNIT
C
UNIT
D
UNIT
A
UNIT
B
UNIT
C
UNIT
D
MINIMUM
RATED
MAXIMUM
MINIMUM
RATED
MAXIMUM
20
20
20
20
1.98
1.98
1.98
1.98
2.45
7.91
9.65
0.98
2.47
3.33
5,62
3.20
A
20
20
20
26
1.90
1.90
1.90
2.46
3.34
8.15
9.94
1.02
2.54
3.43
-
3.21
A
20
20
20
35
1.90
1.90
1.90
3.04
3.59
8.75
10.68
1.09
2.72
3.67
-
3.22
A
20
20
20
52
1.61
1.61
1.61
4.28
3.74
9.12
11.13
1.11
2.78
3.75
-
3.28
A
20
20
26
26
1.90
1.90
2.47
2.47
3.59
8.75
10.68
1.09
2.72
3.67
-
3.22
A
20
20
26
35
1.83
1.83
2.38
2.93
3.67
8.96
10.93
1.11
2.77
3.74
-
3.23
A
20
20
35
35
1.73
1.73
2.78
2.78
3.70
9.02
11.00
1.11
2.78
3.75
-
3.25
A
20
26
26
26
1.83
2.38
2.38
2.38
3.67
8.96
10.93
1.11
2.77
3.74
-
3.23
A
20
26
26
35
1.73
2.26
2.26
2.78
3.70
9.02
11.00
1.11
2.78
3.75
-
3.25
A
20
26
35
35
1.65
2.15
2.64
2.64
3.73
9.09
11.09
1.11
2.78
3.75
-
3.27
A
26
26
26
26
2.26
2.26
2.26
2.26
3.70
9.02
11.00
1.11
2.78
3.75
-
3.25
A
26
26
26
35
2.15
2.15
2.15
2.64
3.73
9.09
11.09
1.11
2.78
3.75
-
3.27
A
RATED CAPACITY
1x4
COMBINATIONS
1x4
HEATING
CAPACITY (KW)
RATED CAPACITY (KW);
UNIT
A
UNIT
B
UNIT
C
UNIT
D
UNIT
A
UNIT
B
UNIT
C
UNIT
D
20
20
20
20
2.20
2.20
2.20
2.20
2.85
20
20
20
26
2.06
2.06
2.06
2.68
20
20
20
35
2.04
2.04
2.04
20
20
20
52
1.79
1.79
20
20
26
26
2.07
20
20
26
35
20
20
35
20
26
20
MINIMUM RATED
INPUT
POWER (KW)
SCOP
(W/W)
COP
(W/W)
ENERGY
CLASS
COP -7
RATED CAPACITY
MAXIMUM
MINIMUM
RATED
MAXIMUM
8.79
10.72
0.91
2.44
3.27
3,85
3.60
A
2.77
3.63
8.86
10.81
0.98
2.45
3.28
-
3.62
A
2.78
3.26
3.85
9.38
11.44
1.04
2.59
3.47
-
3.62
A
2.78
1.79
4.75
4.15
10.13
12.36
1.11
2.78
3.73
-
3.64
A
2.79
2.07
2.69
2.69
3.90
9.51
11.60
1.05
2.63
3.52
-
3.62
A
2.78
1.99
1.99
2.59
3.19
4.00
9.76
11.91
1.08
2.70
3.61
-
3.62
A
2.78
35
1.91
1.91
3.05
3.05
4.07
9.92
12.10
1.09
2.73
3.66
-
3.63
A
2.79
26
26
1.99
2.59
2.59
2.59
4.00
9.76
11.91
1.08
2.70
3.61
-
3.62
A
2.78
26
26
35
1.91
2.48
2.48
3.05
4.07
9.92
12.10
1.09
2.73
3.66
-
3.63
A
2.79
20
26
35
35
1.83
2.38
2.93
2.93
4.13
10.08
12.30
1.11
2.78
3.72
-
3.63
A
2.79
26
26
26
26
2.48
2.48
2.48
2.48
4.07
9.92
12.10
1.09
2.73
3.66
-
3.63
A
2.79
26
26
26
35
2.38
2.38
2.38
2.93
4.13
10.08
12.30
1.11
2.78
3.72
-
3.63
A
2.79
75
RESIDENTIAL
INDOOR UNIT
Inspiration, Innovation, Evolution
INTRODUCTION TO THE
RANGE OF PRODUCTS
RESIDENTIAL RANGE
POWER RANGE
GROUPS OF UNITS
COMBINED SYSTEMS
KAM4-105 DN5
x1
x2
x3
x4
20
20+20
20+20+20
20+20+20+20
26
20+26
20+20+26
20+20+20+26
35
20+35
20+20+35
20+20+20+35
52
20+52
20+20+52
20+20+20+52
26+26
20+26+26
20+20+26+26
26+35
20+26+35
20+20+26+35
26+52
20+26+52
20+20+26+52
35+35
20+35+35
20+20+35+35
35+52
20+35+52
20+20+35+52
52+52
20+52+52
20+20+52+52
26+26+26
20+26+26+26
26+26+35
20+26+26+35
26+26+52
20+26+26+52
26+35+35
20+26+35+35
26+35+52
20+26+35+52
26+52+52
20+26+52+52
35+35+35
20+35+35+35
35+35+52
20+35+35+52
35+52+52
26+26+26+26
26+26+26+35
26+26+26+52
26+26+35+35
26+26+35+52
26+35+35+35
26+35+35+52
35+35+35+35
35+35+35+52
76
RATED
POWER (kW)
COMBINATIONS
1X4
COOLING
CAPACITY (kW)
RATED
INPUT
POWER (kW)
SEER
(W/W)
MAXIMUM MINIMUM RATED MAXIMUM
EER
(W/W)
ENERGY
CLASS
RATED CAPACITY
20
20
20
20
2.04
2.04
2.04
2.04
3.34
8.15
9.78
1.24
2.96
3.62
-
2.75
D
20
20
20
26
1.90
1.90
1.90
2.46
3.34
8.15
9.78
1.24
2.96
3.62
-
2.75
D
20
20
20
35
2.12
2.12
2.12
3.39
4.00
9.75
11.70
1.42
3.37
4.12
-
2.89
C
20
20
20
52
1.96
1.96
1.96
5.18
4.53
11.05
13.26
1.51
3.60
4.39
-
3.07
B
20
20
26
26
2.12
2.12
2.76
2.76
4.00
9.75
11.70
1.42
3.37
4.12
-
2.89
C
20
20
26
35
2.14
2.14
2.79
3.43
4.31
10.50
12.60
1.45
3.45
4.21
-
3.04
B
20
20
26
52
1.86
1.86
2.41
4.92
4.53
11.05
13.26
1.51
3.60
4.39
-
3.07
B
20
20
35
35
2.02
2.02
3.23
3.23
4.31
10.50
12.60
1.45
3.45
4.21
-
3.04
B
20
20
35
52
1.84
1.84
2.95
4.88
4.72
11.52
13.82
1.57
3.74
4.56
-
3.08
B
20
20
52
52
1.67
1.67
4.41
4.41
4.99
12.16
14.59
1.61
3.82
4.67
-
3.18
B
20
26
26
26
2.14
2.79
2.79
2.79
4.31
10.50
12.60
1.42
3.39
4.13
-
3.10
B
20
26
26
35
2.02
2.63
2.63
3.23
4.31
10.50
12.60
1.45
3.45
4.21
-
3.04
B
20
26
26
52
1.84
2.40
2.40
4.88
4.72
11.52
13.82
1.57
3.74
4.56
-
3.08
B
20
26
35
35
2.01
2.61
3.21
3.21
4.53
11.05
13.26
1.51
3.60
4.39
-
3.07
B
20
26
35
52
1.81
2.35
2.89
4.79
4.85
11.84
14.21
1.59
3.78
4.61
-
3.13
B
B
20
26
52
52
1.56
2.03
4.13
4.13
4.85
11.84
14.21
1.59
3.78
4.61
-
3.13
20
35
35
35
1.91
3.05
3.05
3.05
4.53
11.05
13.26
1.51
3.60
4.39
-
3.07
B
20
35
35
52
1.73
2.77
2.77
4.58
4.85
11.84
14.21
1.59
3.78
4.61
-
3.13
B
26
26
26
26
2.63
2.63
2.63
2.63
4.31
10.50
12.81
1.38
3.45
4.32
5,11
3.04
B
26
26
26
35
2.61
2.61
2.61
3.21
4.53
11.05
13.26
1.51
3.60
4.39
-
3.07
B
26
26
26
52
2.29
2.29
2.29
4.66
4.72
11.52
13.82
1.57
3.74
4.56
-
3.08
B
26
26
35
35
2.48
2.48
3.05
3.05
4.53
11.05
13.26
1.51
3.60
4.39
-
3.07
B
26
26
35
52
2.25
2.25
2.77
4.58
4.85
11.84
14.21
1.59
3.78
4.61
-
3.13
B
26
35
35
35
2.46
3.02
3.02
3.02
4.72
11.52
13.82
1.57
3.74
4.56
-
3.08
B
26
35
35
52
2.15
2.65
2.65
4.39
4.85
11.84
14.21
1.59
3.78
4.61
-
3.13
B
35
35
35
35
2.88
2.88
2.88
2.88
4.72
11.52
13.82
1.57
3.74
4.56
-
3.08
B
35
35
35
52
2.61
2.61
2.61
4.33
4.99
12.16
14.59
1.61
3.82
4.67
-
3.18
B
RATED
POWER (kW)
COMBINATIONS
HEATING
CAPACITY (kW)
UNIT A UNIT B UNIT C UNIT D UNIT A UNIT B UNIT C UNIT D MINIMUM
1X4
KEY INSTALLATIONS
COMBINED SYSTEMS
UNIT A UNIT B UNIT C UNIT D UNIT A UNIT B UNIT C UNIT D MINIMUM
SUITE
+
OUTDOOR UNIT
RATED
INPUT
POWER (kW)
MAXIMUM MINIMUM
SCOP
(W/W)
RATED
MAXIMUM
COP
(W/W)
ENERGY
CLASS
COP
-7
RATED CAPACITY
20
20
20
20
2.21
2.21
2.21
2.21
3.70
8.82
10.67
0.99
2.47
3.01
-
2.91
D
2.77
20
20
20
26
2.05
2.05
2.05
2.67
3.70
8.82
10.67
0.99
2.47
3.01
-
2.91
D
2.78
20
20
20
35
2.36
2.36
2.36
3.77
4.56
10.85
13.13
1.44
3.59
4.38
-
3.02
D
2.78
20
20
20
52
1.98
1.98
1.98
5.23
4.69
11.16
13.50
1.36
3.40
4.15
-
3.28
C
2.79
20
20
26
26
2.36
2.36
3.07
3.07
4.56
10.85
13.13
1.44
3.59
4.38
-
3.02
D
2.78
20
20
26
35
2.27
2.27
2.94
3.62
4.66
11.10
13.43
1.35
3.38
4.13
-
3.28
C
2.78
20
20
26
52
1.88
1.88
2.44
4.97
4.69
11.16
13.50
1.36
3.40
4.15
-
3.28
C
2.79
20
20
35
35
2.13
2.13
3.42
3.42
4.66
11.10
13.43
1.35
3.38
4.13
-
3.28
C
2.78
20
20
35
52
1.86
1.86
2.98
4.93
4.88
11.63
14.07
1.41
3.51
4.29
-
3.31
C
2.79
20
20
52
52
1.82
1.82
4.81
4.81
5.57
13.25
16.03
1.58
3.94
4.81
-
3.36
C
2.79
20
26
26
26
2.27
2.94
2.94
2.94
4.66
11.10
13.43
1.35
3.38
4.13
-
3.28
C
2.79
20
26
26
35
2.13
2.78
2.78
3.42
4.66
11.10
13.43
1.35
3.38
4.13
-
3.28
C
2.79
20
26
26
52
1.86
2.42
2.42
4.93
4.88
11.63
14.07
1.41
3.51
4.29
-
3.31
C
2.78
20
26
35
35
2.03
2.64
3.25
3.25
4.69
11.16
13.50
1.36
3.40
4.15
-
3.28
C
2.80
20
26
35
52
1.81
2.35
2.89
4.79
4.97
11.84
14.33
1.51
3.78
4.61
-
3.13
D
2.81
20
26
52
52
1.56
2.03
4.13
4.13
4.97
11.84
14.33
1.51
3.78
4.61
-
3.13
D
2.79
20
35
35
35
1.92
3.08
3.08
3.08
4.69
11.16
13.50
1.36
3.40
4.15
-
3.28
C
2.80
20
35
35
52
1.76
2.81
2.81
4.66
5.06
12.04
14.57
1.45
3.64
4.44
-
3.31
C
2.79
26
26
26
26
2.78
2.78
2.78
2.78
4.55
11.10
13.43
1.35
3.38
4.13
3,80
3.28
C
2.78
26
26
26
35
2.64
2.64
2.64
3.25
4.69
11.16
13.50
1.36
3.40
4.15
-
3.28
C
2.78
26
26
26
52
2.31
2.31
2.31
4.71
4.88
11.63
14.07
1.41
3.51
4.29
-
3.31
C
2.78
26
26
35
35
2.50
2.50
3.08
3.08
4.69
11.16
13.50
1.36
3.40
4.15
-
3.28
C
2.78
26
26
35
52
2.28
2.28
2.81
4.66
5.06
12.04
14.57
1.45
3.64
4.44
-
3.31
C
2.79
26
35
35
35
2.48
3.05
3.05
3.05
4.88
11.63
14.07
1.41
3.51
4.29
-
3.31
C
2.79
26
35
35
52
2.19
2.69
2.69
4.46
5.06
12.04
14.57
1.45
3.64
4.44
-
3.31
C
2.79
35
35
35
35
2.91
2.91
2.91
2.91
4.88
11.63
14.07
1.41
3.51
4.29
-
3.31
C
2.79
35
35
35
52
2.85
2.85
2.85
4.71
5.57
13.25
16.03
1.58
3.94
4.81
-
3.36
C
2.79
77
RESIDENTIAL
INDOOR UNIT
Inspiration, Innovation, Evolution
RESIDENTIAL RANGE
INTRODUCTION TO THE
RANGE OF PRODUCTS
POWER RANGE
GROUPS OF UNITS
COMBINED SYSTEMS
KAM5-105 DNS
x1
x2
x4
x5
20
20+20
20+20+20
20+20+20+20
20+20+20+20+20
26
20+26
20+20+26
20+20+20+26
20+20+20+20+26
35
20+35
20+20+35
20+20+20+35
20+20+20+20+35
52
20+52
20+20+52
20+20+20+52
20+20+20+20+52
26+26
20+26+26
20+20+26+26
20+20+20+26+26
26+35
20+26+35
20+20+26+35
20+20+20+26+35
26+52
20+26+52
20+20+26+52
20+20+20+26+52
35+35
20+35+35
20+20+35+35
20+20+20+35+52
35+52
20+35+52
20+20+35+52
20+20+20+52+52
52+52
78
x3
20+52+52
20+20+52+52
20+20+26+26+26
26+26+26
20+26+26+26
20+20+26+26+35
26+26+35
20+26+26+35
20+20+26+26+52
26+26+52
20+26+26+52
20+20+26+35+52
26+35+35
20+26+35+35
20+20+35+35+52
26+35+52
20+26+35+52
20+26+26+26+26
26+52+52
20+26+52+52
20+26+26+26+35
35+35+35
20+35+35+35
20+26+26+26+52
35+35+52
20+35+35+52
20+26+26+35+35
35+52+52
20+35+52+52
20+26+26+35+52
26+26+26+26
20+26+35+35+35
26+26+26+35
20+26+35+35+52
26+26+26+52
26+26+26+26+26
26+26+35+35
26+26+26+26+35
26+26+35+52
26+26+26+26+52
26+26+52+52
26+26+26+35+35
26+35+35+35
26+26+26+35+52
26+35+35+52
26+26+35+35+35
35+35+35+35
26+35+35+35+35
35+35+35+52
35+35+35+35+35
UNIT A
UNIT B
UNIT C
20
20
20
20
20
20
20
20
26
20
20
20
20
26
20
20
20
20
20
20
20
26
26
20
20
20
20
26
26
26
35
20
20
20
20
20
26
20
20
26
20
26
20
20
26
20
26
20
20
26
26
20
26
26
26
20
20
26
26
26
35
35
20
20
20
26
20
26
26
20
26
20
26
26
20
26
20
26
35
20
26
35
26
26
35
26
35
20
35
26
26
35
35
COOLING
CAPACITY (kW)
UNIT D UNIT E UNIT A UNIT B UNIT C UNIT D UNIT E
20
20
20
26
26
26
26
35
26
20
26
35
26
26
26
35
35
35
26
35
35
26
35
35
35
52
35
35
35
35
35
20
26
35
26
35
26
35
35
26
52
35
35
52
35
26
35
35
52
52
35
52
52
35
52
52
52
52
35
52
35
35
2.02
1.94
1.95
1.83
1.88
1.79
1.79
1.91
2.37
1.82
1.74
2.01
1.80
2.20
2.28
1.73
1.77
1.83
1.59
1.70
1.53
2.07
2.20
1.62
1.65
1.63
1.66
2.48
2.17
2.25
2.21
2.02
1.94
1.95
1.83
1.88
2.32
1.79
1.91
2.37
1.82
2.26
2.01
1.80
2.20
2.28
2.25
1.77
1.83
2.07
2.20
1.53
2.07
2.20
2.11
1.65
1.63
2.15
2.48
2.17
2.25
2.21
2.02
1.94
1.95
2.38
1.88
2.32
2.32
1.91
2.37
1.82
2.26
2.61
1.80
2.20
2.28
2.25
2.83
1.83
2.07
2.71
1.99
2.07
2.70
2.11
2.64
1.63
2.65
2.48
2.17
2.77
2.73
2.02
1.94
1.95
2.38
2.44
2.32
2.32
3.06
2.37
1.82
2.26
3.21
2.34
2.20
2.97
2.77
2.83
2.93
2.07
2.71
2.45
2.07
2.70
2.59
2.64
4.32
2.65
3.05
2.68
2.77
2.73
RATED
POWER (kW)
COMBINATIONS
5x1
20
20
20
20
20
20
26
20
20
26
20
26
20
20
26
26
20
20
26
26
26
20
26
26
26
20
20
26
35
26
35
20
20
20
20
26
20
26
26
20
26
20
26
26
20
26
26
35
20
26
26
35
26
26
35
26
35
20
26
35
35
35
20
20
26
20
26
26
26
26
35
26
20
26
35
26
26
35
35
35
35
26
35
35
26
35
35
35
52
35
35
35
35
20
26
26
35
26
35
26
35
35
26
52
35
35
52
35
35
35
52
35
52
35
52
52
35
52
52
52
52
35
52
35
2.11
2.04
2.01
1.89
2.01
1.94
1.86
1.90
1.87
1.77
1.94
1.90
1.85
1.86
1.89
1.81
1.90
1.85
1.86
1.89
1.81
1.89
1.80
2.40
2.45
2.35
2.43
2.34
2.44
2.40
2.38
2.11
2.04
2.01
1.89
2.01
1.94
1.86
1.90
1.87
1.77
1.94
1.90
1.85
1.86
1.89
1.81
2.46
2.40
2.42
2.45
2.35
2.45
2.34
2.40
2.45
2.35
2.43
2.34
2.44
2.40
2.38
2.11
2.04
2.01
1.89
2.01
1.94
1.86
1.90
1.87
1.77
2.52
2.46
2.40
2.42
3.02
2.90
2.46
2.40
2.42
2.45
2.35
3.02
2.88
2.40
2.45
2.35
2.43
2.34
3.00
2.95
2.93
2.11
2.04
2.01
1.89
2.61
2.52
2.42
3.03
3.00
4.68
2.52
2.46
2.95
2.97
3.02
2.90
2.46
2.40
2.42
3.02
2.90
3.02
2.88
2.40
2.45
2.35
2.99
2.88
3.00
2.95
2.93
2.02
2.53
3.11
2.38
3.00
2.32
2.86
3.06
2.37
4.83
2.79
3.21
4.77
2.71
2.97
2.77
2.83
4.85
4.22
2.71
4.06
4.23
2.70
4.30
4.38
4.32
4.39
3.05
4.43
2.77
2.73
2.11
2.65
3.21
5.01
2.61
3.10
4.93
3.03
4.96
4.68
2.52
3.03
2.95
4.92
3.02
4.80
2.46
2.95
4.92
3.02
4.80
3.02
4.77
2.40
3.02
4.80
2.99
4.77
3.00
2.95
2.93
INPUT
POWER (kW)
MIN.
RAT.
MAX.
MIN.
RAT.
MAX.
4.14
4.22
4.47
4.43
4.54
4.55
4.55
4.87
4.87
4.97
4.64
5.35
5.13
4.73
5.24
4.83
4.93
5.44
4.93
4.93
4.75
5.13
5.13
5.22
5.31
5.55
5.54
5.55
5.59
5.47
5.59
10.10
10.30
10.50
10.81
11.09
11.09
11.09
11.09
11.87
12.13
12.13
12.23
12.23
12.23
12.35
12.35
12.38
12.38
12.45
12.45
12.64
12.76
12.76
12.95
13.43
13.89
13.89
13.89
13.89
13.89
14.24
12.28
12.38
12.56
12.60
12.92
12.92
12.92
12.92
12.92
13.01
13.01
13.05
13.06
13.06
13.09
13.09
13.10
13.10
13.20
13.20
13.25
13.31
13.31
13.35
13.67
13.80
13.80
13.80
13.80
13.80
14.35
1.36
1.39
1.45
1.46
1.48
1.48
1.49
1.60
1.62
1.67
1.52
1.76
1.72
1.57
1.72
1.57
1.62
1.81
1.65
1.62
1.57
1.72
1.72
1.71
1.76
1.86
1.85
1.85
1.90
1.84
1.90
3.24
3.30
3.46
3.47
3.52
3.52
3.54
3.80
3.85
3.98
3.63
4.18
4.09
3.74
4.10
3.74
3.85
4.31
3.93
3.85
3.75
4.10
4.08
4.07
4.19
4.42
4.42
4.39
4.53
4.37
4.53
3.95
4.03
4.22
4.23
4.29
4.29
4.32
4.64
4.70
4.85
4.43
5.10
4.99
4.57
5.00
4.56
4.70
5.26
4.80
4.69
4.57
5.01
4.98
4.96
5.12
5.39
5.39
5.36
5.52
5.34
5.52
HEATING
CAPACITY (kW)
UNIT A UNIT B UNIT C UNIT D UNIT E UNIT A UNIT B UNIT C UNIT D UNIT E
20
20
20
20
20
20
20
20
20
26
20
20
20
20
26
20
20
20
26
20
20
20
26
26
20
20
20
26
26
20
35
SUITE
KEY INSTALLATIONS
COMBINED SYSTEMS
RATED
POWER (kW)
COMBINATIONS
5X1
+
OUTDOOR UNIT
INPUT
POWER (kW)
SCOP
(W/W)
SEER
(W/W)
EER
(W/W)
ENERGY
CLASS
RATED CAPACITY
5,32
-
COP
(W/W)
MIN.
RAT.
MAX.
MIN.
RAT.
MAX.
RATED CAPACITY
4.44
4.54
4.73
5.28
4.73
4.80
5.43
4.94
5.70
6.16
4.80
4.94
5.04
5.89
5.38
5.97
4.94
5.04
5.89
5.38
5.97
5.63
6.16
5.04
5.38
5.97
5.58
6.16
5.83
5.97
6.16
10.46
11.06
11.66
11.46
11.74
12.03
12.47
12.76
13.05
12.82
12.62
12.90
12.92
13.20
12.94
13.08
13.35
13.34
13.77
14.04
13.90
14.16
14.43
14.28
14.54
14.96
15.23
15.54
15.54
15.47
16.19
12.31
13.01
13.71
13.48
13.81
14.15
13.86
14.18
14.50
14.24
14.02
14.02
14.05
14.35
14.06
14.07
14.36
14.35
14.35
14.63
14.47
14.75
15.03
14.87
15.15
15.42
15.70
15.70
15.70
15.63
16.35
1.15
1.18
1.24
1.44
1.24
1.26
1.48
1.32
1.57
1.71
1.24
1.30
1.35
1.62
1.46
1.65
1.29
1.34
1.62
1.44
1.65
1.53
1.70
1.36
1.43
1.65
1.51
1.67
1.59
1.65
1.72
2.89
2.96
3.11
3.60
3.11
3.15
3.70
3.30
3.92
4.29
3.09
3.25
3.38
4.05
3.65
4.12
3.22
3.35
4.05
3.60
4.12
3.82
4.25
3.40
3.58
4.12
3.78
4.18
3.99
4.13
4.30
3.52
3.61
3.79
4.39
3.79
3.84
4.52
4.03
4.79
5.23
3.78
3.96
4.12
4.95
4.46
5.02
3.93
4.09
4.95
4.39
5.02
4.66
5.18
4.15
4.37
5.02
4.61
5.10
4.86
5.04
5.24
3,42
-
3.69
3.68
3.65
3.52
3.65
3.66
3.52
3.59
3.49
3.45
3.72
3.65
3.58
3.49
3.54
3.48
3.68
3.61
3.49
3.59
3.48
3.54
3.48
3.56
3.61
3.48
3.55
3.54
3.51
3.47
3.44
3.15
3.15
3.18
3.15
3.18
3.18
3.16
3.15
3.11
3.08
3.15
3.15
3.09
3.11
3.15
3.18
3.15
3.11
3.09
3.16
3.12
3.08
3.09
3.16
3.12
3.09
3.09
3.11
3.04
3.08
3.04
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
ENERGY
CLASS
COP -7
A
A
A
B
A
A
B
B
B
B
A
A
B
B
B
B
A
B
B
B
B
B
B
B
B
B
B
B
B
B
B
2.81
2.80
2.78
2.68
2.78
2.79
2.68
2.73
2.66
2.63
2.83
2.78
2.73
2.66
2.70
2.65
2.80
2.75
2.66
2.73
2.65
2.70
2.65
2.71
2.73
2.65
2.71
2.67
2.70
2.55
2.43
79
RESIDENTIAL
INDOOR UNIT
Inspiration, Innovation, Evolution
RESIDENTIAL RANGE
INTRODUCTION TO THE
RANGE OF PRODUCTS
GROUPS OF UNITS
POWER RANGE
COMBINED SYSTEMS
KAM5-120 DN5
x1
x2
x3
20
20+20
20+20+20
20+20+20+20
26
20+26
20+20+26
20+20+20+26
35
20+35
20+20+35
20+20+20+35
52
20+52
20+20+52
20+20+26+26
26+26
20+26+26
20+20+26+35
26+35
20+26+35
20+26+26+26
26+52
20+35+35
20+26+26+35
35+35
26+26+26
26+26+26+26
35+52
26+26+35
26+26+26+35
26+35+35
80
x4
COOLING
CAPACITY (kW)
UNIT A UNIT B UNIT C UNIT D UNIT E UNIT A UNIT B UNIT C UNIT D UNIT E
5x1
20
20
20
20
20
20
20
20
26
20
20
20
20
26
20
20
20
20
20
20
20
26
26
20
20
20
20
26
26
26
35
20
20
20
20
20
26
20
20
26
20
26
20
20
26
20
26
20
20
26
26
20
26
26
26
20
20
26
26
26
35
35
20
20
20
26
20
26
26
20
26
20
26
26
20
26
20
26
35
20
26
35
26
26
35
26
35
20
35
26
26
35
35
20
20
20
26
26
26
26
35
26
20
26
35
26
26
26
35
35
35
26
35
35
26
35
35
35
52
35
35
35
35
35
20
26
35
26
35
26
35
35
26
52
35
35
52
35
26
35
35
52
52
35
52
52
35
52
52
52
52
35
52
35
35
2.42
2.33
2.34
2.20
2.25
2.15
2.15
2.30
2.85
2.19
2.09
2.41
2.16
2.65
2.74
2.08
2.12
2.20
1.91
2.03
1.84
2.49
2.64
1.95
1.98
1.96
1.99
2.97
2.61
2.70
2.66
COMBINATIONS
2.42
2.33
2.34
2.20
2.25
2.79
2.15
2.30
2.85
2.19
2.72
2.41
2.16
2.65
2.74
2.70
2.12
2.20
2.49
2.64
1.84
2.49
2.64
2.53
1.98
1.96
2.59
2.97
2.61
2.70
2.66
2.42
2.33
2.34
2.86
2.25
2.79
2.79
2.30
2.85
2.19
2.72
3.13
2.16
2.65
2.74
2.70
3.39
2.20
2.49
3.25
2.39
2.49
3.24
2.53
3.17
1.96
3.18
2.97
2.61
3.33
3.27
2.42
2.33
2.34
2.86
2.93
2.79
2.79
3.67
2.85
2.19
2.72
3.85
2.81
2.65
3.56
3.32
3.39
3.52
2.49
3.25
2.94
2.49
3.24
3.11
3.17
5.18
3.18
3.66
3.21
3.33
3.27
2.42
3.03
3.74
2.86
3.60
2.79
3.43
3.67
2.85
5.80
3.34
3.85
5.73
3.26
3.56
3.32
3.39
5.82
5.07
3.25
4.87
5.07
3.24
5.16
5.25
5.18
5.27
3.66
5.32
3.33
3.27
RATED CAPACITY (KW);
UNIT A UNIT B UNIT C UNIT D UNIT E UNIT A UNIT B UNIT C UNIT D UNIT E
5x1
20
20
20
20
20
20
20
20
20
26
20
20
20
20
26
20
20
20
26
20
20
20
26
26
20
20
20
26
26
20
35
20
20
20
20
20
20
26
20
20
26
20
26
20
20
26
26
20
20
26
26
26
20
26
26
26
20
20
26
35
26
35
20
20
20
20
26
20
26
26
20
26
20
26
26
20
26
26
35
20
26
26
35
26
26
35
26
35
20
26
35
35
35
20
20
26
20
26
26
26
26
35
26
20
26
35
26
26
35
35
35
35
26
35
35
26
35
35
35
52
35
35
35
35
20
26
26
35
26
35
26
35
35
26
52
35
35
52
35
35
35
52
35
52
35
52
52
35
52
52
52
52
35
52
35
2.43
2.34
2.31
2.17
2.31
2.23
2.14
2.18
2.15
2.03
2.23
2.18
2.12
2.14
2.17
2.08
2.18
2.12
2.14
2.17
2.08
2.17
2.07
2.76
2.82
2.71
2.80
2.69
2.80
2.76
2.74
2.43
2.34
2.31
2.17
2.31
2.23
2.14
2.18
2.15
2.03
2.23
2.18
2.12
2.14
2.17
2.08
2.83
2.76
2.78
2.82
2.71
2.82
2.69
2.76
2.82
2.71
2.80
2.69
2.80
2.76
2.74
2.43
2.34
2.31
2.17
2.31
2.23
2.14
2.18
2.15
2.03
2.89
2.83
2.76
2.78
3.47
3.33
2.83
2.76
2.78
2.82
2.71
3.47
3.31
2.76
2.82
2.71
2.80
2.69
3.45
3.40
3.37
KEY INSTALLATIONS
COMBINED SYSTEMS
RATED
POWER (kW)
COMBINATIONS
2.43
2.34
2.31
2.17
3.00
2.89
2.78
3.49
3.45
5.38
2.89
2.83
3.40
3.42
3.47
3.33
2.83
2.76
2.78
3.47
3.33
3.47
3.31
2.76
2.82
2.71
3.44
3.31
3.45
3.40
3.37
2.43
3.05
3.70
5.76
3.00
3.56
5.67
3.49
5.71
5.38
2.89
3.49
3.40
5.66
3.47
5.52
2.83
3.40
5.66
3.47
5.52
3.47
5.48
2.76
3.47
5.52
3.44
5.48
3.45
3.40
3.37
MIN.
RAT.
4.97
12.12
5.07
12.36
5.36
12.60
5.32
12.97
5.45
13.31
5.45
13.30
5.45
13.30
5.84
13.31
5.84
14.24
5.97
14.56
5.57
14.56
6.42
14.68
6.16
14.68
5.67
14.68
6.29
14.82
5.79
14.82
5.91
14.86
6.53
14.86
5.92
14.94
5.92
14.94
5.69
15.17
6.16
15.31
6.15
15.31
6.26
15.54
6.38
16.12
6.66
16.67
6.65
16.67
6.66
16.67
6.71
16.67
6.56
16.67
6.71
17.09
HEATING
CAPACITY (KW)
SUITE
+
OUTDOOR UNIT
INPUT
POWER (kW)
MAX.
MIN.
RAT.
14.74
14.86
15.07
15.12
15.50
15.50
15.50
15.50
15.50
15.61
15.61
15.66
15.67
15.67
15.71
15.71
15.72
15.72
15.84
15.84
15.90
15.97
15.97
16.02
16.40
16.56
16.56
16.56
16.56
16.56
17.22
1.63
3.88
1.66
3.96
1.74
4.15
1.75
4.16
1.77
4.22
1.77
4.22
1.79
4.25
1.92
4.56
1.94
4.62
2.00
4.77
1.83
4.35
2.11
5.02
2.06
4.91
1.89
4.49
2.06
4.91
1.88
4.48
1.94
4.62
2.17
5.17
1.98
4.72
1.94
4.61
1.89
4.49
2.07
4.93
2.06
4.90
2.05
4.88
2.11
5.03
2.23
5.31
2.23
5.30
2.21
5.27
2.28
5.43
2.20
5.25
2.28
5.43
INPUT
POWER (KW)
EER
MAX.
ENERGY CLASS
RATED
CAPACITY
4.74
4.83
5.07
5.07
5.15
5.15
5.19
5.57
5.64
5.82
5.31
6.12
5.99
5.48
6.00
5.47
5.64
6.31
5.76
5.63
5.48
6.01
5.98
5.95
6.14
6.47
6.46
6.43
6.63
6.40
6.63
3.15
3.15
3.18
3.15
3.18
3.18
3.16
3.15
3.11
3.08
3.15
3.15
3.09
3.11
3.15
3.18
3.15
3.11
3.09
3.16
3.12
3.08
3.09
3.16
3.12
3.09
3.09
3.11
3.04
3.08
3.04
COP
(W/W)
MIN.
RAT.
MAX.
MIN.
RAT.
MAX.
RATED
CAPACITY
5.10
5.22
5.43
6.07
5.43
5.52
6.25
5.68
6.56
7.08
5.52
5.68
5.80
6.78
6.19
6.86
5.68
5.80
6.78
6.19
6.86
6.47
7.08
5.80
6.19
6.86
6.42
7.08
6.70
6.86
7.08
12.03
12.72
13.40
13.17
13.50
13.83
14.34
14.68
15.01
14.74
14.51
14.83
14.86
15.18
14.88
15.05
15.35
15.34
15.84
16.15
15.98
16.29
16.59
16.42
16.72
17.20
17.51
17.87
17.87
17.80
18.61
14.15
14.96
15.77
15.50
15.89
16.27
15.94
16.31
16.68
16.38
16.12
16.12
16.15
16.50
16.17
16.18
16.51
16.50
16.50
16.82
16.65
16.97
17.29
17.10
17.42
17.74
18.05
18.05
18.05
17.98
18.80
1.33
1.36
1.43
1.66
1.43
1.45
1.70
1.52
1.81
1.97
1.42
1.49
1.55
1.87
1.68
1.89
1.48
1.54
1.87
1.66
1.89
1.76
1.95
1.56
1.65
1.89
1.74
1.92
1.83
1.90
1.98
3.32
3.40
3.57
4.14
3.57
3.62
4.26
3.80
4.51
4.93
3.56
3.73
3.89
4.66
4.20
4.74
3.70
3.85
4.66
4.14
4.74
4.39
4.89
3.91
4.12
4.74
4.34
4.80
4.58
4.75
4.94
4.05
4.15
4.36
5.05
4.36
4.41
5.20
4.63
5.51
6.01
4.34
4.55
4.74
5.69
5.12
5.78
4.52
4.70
5.69
5.05
5.78
5.36
5.96
4.77
5.02
5.78
5.30
5.86
5.59
5.80
6.03
3.69
3.68
3.65
3.52
3.65
3.66
3.52
3.59
3.49
3.45
3.72
3.65
3.58
3.49
3.54
3.48
3.68
3.61
3.49
3.59
3.48
3.54
3.48
3.56
3.61
3.48
3.55
3.54
3.51
3.47
3.44
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
ENERGY
CLASS
COP -7
A
A
A
B
A
A
B
B
B
B
A
A
B
B
B
B
A
B
B
B
B
B
B
B
B
B
B
B
B
B
B
2.81
2.80
2.78
2.68
2.78
2.79
2.68
2.73
2.66
2.63
2.83
2.78
2.73
2.66
2.70
2.65
2.80
2.75
2.66
2.73
2.65
2.70
2.65
2.71
2.73
2.65
2.71
2.67
2.70
2.55
2.43
81
RESIDENTIAL
INDOOR UNIT
Inspiration, Innovation, Evolution
RESIDENTIAL RANGE
REFERENCES
KEY INSTALLATIONS
CELLER CAN ROCA
RESTAURANT
Location: Girona
Initial situation:
Units installed: Multisystem DC Inverter
Capacity: 20 kW
82
INTRODUCTION TO THE
RANGE OF PRODUCTS
POWER RANGE
GROUPS OF UNITS
+
COMBINED SYSTEMS
SUITE
OUTDOOR UNIT
KEY INSTALLATIONS
83
RESIDENTIAL
INDOOR UNITS
Inspiration, Innovation, Evolution
RESIDENTIAL RANGE
POWER RANGE
INTRODUCTION TO THE
RANGE OF PRODUCTS
GROUPS OF UNITS
THE SUITE RESIDENTIAL RANGE IS PRESENT IN THE MOST COMMON PLACES. FROM APARTMENTS TO HOSPITALS, SCHOOLS AND
UNIVERSITIES, THE COMFORT AND TECHNOLOGY OF THIS RANGE PROVIDES THE WELL-BEING THAT ALL HOMES NEED.
VILLA BAHIA PRINCIPE
RESIDENTIAL
Location: Dominican Republic
Initial situation: New construction
Units installed: Multisystem DC Inverter
Capacity: 34 kW
OTHER CUSTOMERS THAT TRUSTED KAYSUN SUITE
HOTELS
Vera Apartment Hotel (Almeria),
Sangulí Resort Salou (Tarragona)
SCHOOLS AND UNIVERSITIES
University of Salamanca (Salamanca),
The Capuchins School (Murcia), María
Maroto School (Murcia), Autism
Association of Jerez (Cádiz)
LEISURE CENTRES
Vals Sport - Sports Centre (Malaga)
84
HOSPITAL, CLINICS AND HEALTH
CENTRES Jesus Nazareno Hospital
(Córdoba), Santomera Health Centre
(Murcia)
BUSINESS CENTRES AND OFFICES
ISOLAIS Office (Seville)
RESIDENCES
51 residences in Carrión (Seville),
52 residences in Torreblanca (Seville),
Detached house (Palma), La Pineda
Apartments (Tarragona),
Puerto Mahón Apartments (Majorca),
Jardines de Santa Ana Residences
(Seville)
+
COMBINED SYSTEMS
KEY INSTALLATIONS
PAGÉS DEL CORRO
CASTILLEJA DE LA CUESTA
RESIDENTIAL
RESIDENTIAL
Location: Seville
Initial situation: New construction
Units installed: Multisystem DC Inverter
Capacity: 396 kW
Location: Seville
Initial situation: New construction
Units installed: On/Off
Capacity: 112 kW
TEKNON RETINE INSTITUTE
UNIVERSITY OF SALAMANCA
MEDICAL CENTRE
SCHOOLS AND UNIVERSITIES
Location: Barcelona
Initial situation: Renovation
Units installed: Multisystem DC Inverter
Capacity: 73 kW
Location: Salamanca
Initial situation: Renovation
Units installed: Multisystem DC Inverter
Capacity: 150 kW
LA ROCA
502 PROPERTY DEVELOPMENT
HOTEL
Location: Malaga
Initial situation: New construction
Units installed: Multisystem DC Inverter
Capacity: 236 kW
SUITE
OUTDOOR UNIT
RESIDENTIAL
Location: Seville
Initial situation: New construction
Units installed: Multisystem DC Inverter
Capacity: 4 MW
85
RESIDENTIAL
INDOOR UNITS

Similar documents

Die BUCHSTAVIER - Das Dosierte Leben

Die BUCHSTAVIER - Das Dosierte Leben Das Dosierte Leben Das Avant-Avantgarde-Magazin 16. Jahrgang

More information

Argo_Professional_Katalog_2011

Argo_Professional_Katalog_2011 ABCDEFG (kW/kW) mK l/h mm W.C. n° dB(A) dB(A) dB(A) dB(A) V/Ph/Hz kW kWh

More information