Argo_Professional_Katalog_2011

Transcription

Argo_Professional_Katalog_2011
SPLIT/PACKAGE
SPLIT/PACKAGE
DCI ON OFF
SPLIT/PACKAGE DCI
DCI
Split og pac inverter varmepumper op til 14 kW
Til væg, loft eller indbygningsmontage
www.argoclima.com
www.koelegruppen.dk
31
PACKAGE DC INVERTER
eco
auto restart
R410A
ifeel
washable
filters
3speed
+43°C
-15°C
AWS 71 PH/H3
• PAM DC Inverter teknologi
• Automatisk skift mellem køl og varme
• Natfunktion
• Affugtning
• 3-hastigheds ventilator
• Flap som kan indstilles til fast eller varierende luftfordeling
• Vertikal flap til manuel styring
• Auto restart efter strømsvigt
• Elektronisk sikring mod strømsvigt
• Driftsikker i både køl og varme ned til -15°C
• 230V eller 400V forsyning
• Højeffektivitets kompressor
PRODUCT NAME
Indoor unit
Outdoor unit
Features
Cooling/Heating capacity - nominal (min-max)
Energy label class
E.E.R. / C.O.P.
Air flowrate Indoor (h.m.l.)
Dehumidification
Fan speeds (Indoor / Outdoor)
Sound pressure Indoor (h.m.l.)
Sound pressure Outdoor (h.)
Power supply
Running consumption
Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE
Compressor type
Refrigerant type
Liquid pipe diameter
Gas pipe diameter
Max. pipe lenght with gas standard charge
Max. pipe lenght with gas additional charge
Gas additional charge
Max. height between units (Outdoor on top)
Max. height between units (Indoor on top)
Net weight Indoor / Outdoor
Net dimension Indoor (H./W./D.)
Net dimension Outdoor (H./W./D.)
Units
kW
BTU/h
kcal/h
ABCDEFG
(kW/kW)
m³/h
l/h
n°
dB(A)
dB(A)
V/Ph/Hz
kW
kWh
mm(inch")
mm(inch")
m
m
gr/m
m
m
Kg
mm
mm
AWS71PH/H3/H3B
AWS71PH
AES71PIH/H3/H3B
Cooling
Heating
7,10 (2,2-8,0)
8,00 (2,2-9,0)
24.000
27.000
6.100
6.880
B
B
3,01
3,54
1.140-1.020-840
4,0
3 + Auto / 3 (Auto)
41-37-34
49
230/1/50-400/3/50
2,36
2,26
1.180
DCInverter Twin Rotary
R410A
9,52(3/8")
15,88(5/8")
30
50
40
50
30
21/58
330x1.140x228
780x940x340
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
32 www.argoclima.com
www.koelegruppen.dk
PACKAGE DC INVERTER
eco
auto restart
R410A
ifeel
washable
filters
3speed
+43°C
-15°C
ASS 71/100 PH/H3
• PAM DC Inverter teknologi
• Automatisk skift mellem køl og varme
• Natfunktion
• Affugtning
• 3-hastigheds ventilator
• Flap som kan indstilles til fast eller varierende luftfordeling
• Auto restart efter strømsvigt
• Elektronisk sikring mod strømsvigt
• Driftsikker i både køl og varme ned til -15°C
• 230V eller 400V forsyning
• Højeffektivitets kompressor
PRODUCT NAME
Indoor unit
Outdoor unit (1ph/3ph)
Features
Cooling/Heating capacity - nominal (min-max)
Energy label class
E.E.R. / C.O.P.
Air flowrate Indoor (h.m.l.)
Dehumidification
Fan speeds (Indoor / Outdoor)
Sound pressure Indoor (h.m.l.)
Sound pressure Outdoor (h.)
Power supply (1ph-3ph)
Running consumption
Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE
Compressor type
Refrigerant type
Liquid pipe diameter
Gas pipe diameter
Max. pipe lenght with gas standard charge
Max. pipe lenght with gas additional charge
Max. height between units (Outdoor on top)
Max. height between units (Indoor on top)
Net weight Indoor / Outdoor
Net dimension Indoor (H./W./D.)
Net dimension Outdoor (H./W./D.)
Units
kW
BTU/h
kcal/h
ABCDEFG
(kW/kW)
m³/h
l/h
n°
dB(A)
dB(A)
V/Ph/Hz
kW
kWh
mm(inch")
mm(inch")
m
m
m
m
Kg
mm
mm
ASS71PH/H3/H3B
ASS71PH
AES71PIH/H3/H3B
Cooling
Heating
7,10 (2,2-8,0)
8,00 (2,2-9,0)
24.000
27.000
6.100
6.880
A
A
3,33
3,86
1.140-1.020-840
3,6
3 + Auto / variable
47-45-41
47
49
230/1/50 - 400/3/50
2,13
2,07
1.065
DCInverter Twin Rotary
R410A
9,52(3/8")
15,88(5/8")
30
50
30
15
28/58
338x860x860
780x940x340
SPLIT/PACKAGE ON OFF
• Vaskbare filtre
ASS100PH/H3/H3B
ASS100PH
AES100PIH/H3/H3B
Cooling
Heating
10,00 (2,2-11,2)
11,20 (2,2-12,50)
34.000
38.000
8.600
9.630
A
A
3,21
3,78
1.920-1.680-1.320
4,6
3 + Auto / variable
53-50-46
51
52
230/1/50 - 400/3/50
3,12
2,96
1.560
DCInverter Twin Rotary
R410A
9,52(3/8")
15,88(5/8")
30
50
30
15
35/65
338x1.150x860
780x940x340
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
www.argoclima.com
www.koelegruppen.dk
33
PACKAGE DC INVERTER
eco
auto restart
R410A
H
ifeel
washable
filters
3speed
H3
+43°C
-15°C
H3B
ASS 125 PH/H3
• PAM DC Inverter teknologi
• Automatisk skift mellem køl og varme
• Natfunktion
• Affugtning
• 3-hastigheds ventilator
• Flap som kan indstilles til fast eller varierende luftfordeling
• Auto restart efter strømsvigt
• Elektronisk sikring mod strømsvigt
• Driftsikker i både køl og varme ned til -15°C
• 230V eller 400V forsyning
• Højeffektivitets kompressor
• Vaskbare filtre
PRODUCT NAME
Indoor unit
Outdoor unit (1ph/3ph)
Features
Cooling/Heating capacity - nominal (min-max)
Energy label class
E.E.R. / C.O.P.
Air flowrate Indoor (h.m.l.)
Dehumidification
Fan speeds (Indoor / Outdoor)
Sound pressure Indoor (h.m.l.)
Sound pressure Outdoor (h.)
Power supply (1ph-3ph)
Running consumption
Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE
Compressor type
Refrigerant type
Liquid pipe diameter
Gas pipe diameter
Max. pipe lenght with gas standard charge
Max. pipe lenght with gas additional charge
Max. height between units (Outdoor on top)
Max. height between units (Indoor on top)
Net weight Indoor / Outdoor
Net dimension Indoor (H./W./D.)
Net dimension Outdoor (H./W./D.)
Units
kW
BTU/h
kcal/h
ABCDEFG
(kW/kW)
m³/h
l/h
n°
dB(A)
dB(A)
V/Ph/Hz
kW
kWh
mm(inch")
mm(inch")
m
m
m
m
Kg
mm
mm
ASS125PH/H3/H3B
ASS125PH
AES125PIH/H3/H3B
Cooling
Heating
12,50 (2,7-14,0)
14,00 (2,7-16,00)
42.500
48.000
10.750
12.040
A
A
3,24
3,66
1.920-1.680-1.320
6,3
3 + Auto / variable
53-50-46
52
53
230/1/50 - 400/3/50
3,86
3,83
1.930
DCInverter Twin Rotary
R410A
9,52(3/8")
15,88(5/8")
30
50
30
15
35/100
338x1.150x860
1.230x940x340
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
34 www.argoclima.com
www.koelegruppen.dk
PACKAGE DC INVERTER
eco
auto restart
R410A
ifeel
integrated
plenum
3speed
+43°C
-15°C
ADS 71 PH/H3
• PAM DC Inverter teknologi
• Trevejs rørtilslutning
• Automatisk skift mellem køl og varme
• Natfunktion
• Affugtning
• Auto restart efter strømsvigt
• Elektronisk sikring mod strømsvigt
• Driftsikker i både køl og varme ned til -15°C
• 230V eller 400V forsyning
• Højeffektivitets kompressor
• Vaskbare filtre
Cooling/Heating capacity - nominal (min-max)
Energy label class
E.E.R. / C.O.P.
Air flowrate (h.m.l.)
Dehumidification
External static pressure (min-max)
Fan speeds (Indoor / Outdoor)
Sound power Indoor (h.m.l.)
Sound pressure Indoor (h.m.l.)
Sound pressure Indoor at ducts exit
Sound pressure Outdoor (h.)
Power supply (1ph-3ph)
Running consumption - nominal (min-max)
Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE
Compressor type
Refrigerant type
Liquid pipe diameter
Gas pipe diameter
Max. pipe lenght with gas standard charge
Max. pipe lenght with gas additional charge
Max. height between units (Outdoor on top)
Max. height between units (Indoor on top)
Ducts diameter
Net weight Indoor / Outdoor
Net dimension Indoor (H./W./D.)
Net dimension Outdoor (H./W./D.)
Units
kW
BTU/h
kcal/h
ABCDEFG
(kW/kW)
mK
l/h
mm W.C.
n°
dB(A)
dB(A)
dB(A)
dB(A)
V/Ph/Hz
kW
kWh
mm(inch")
mm(inch")
m
m
m
m
mm
Kg
mm
mm
ADS71PH/H3/H3B
ADS71PH
AES71PIH/H3/H3B
Cooling
Heating
7,10 (2,2-8,0)
8,00 (2,2-9,0)
24.000
27.000
6.100
6.880
C
C
2,83
3,35
1.080-900-780
3,5
5-10
3 + Auto / variable
43-39-36
34-30-27
20
47
49
230/1/50 - 400/3/50
2,51
2,39
1.255
DCInverter Twin Rotary
R410A
9,52(3/8")
15,88(5/8")
30
50
30
15
200
32/58
310x1.000x630
780x940x340
SPLIT/PACKAGE ON OFF
PRODUCT NAME
Indoor unit
Outdoor unit (1ph/3ph)
Features
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
www.argoclima.com
www.koelegruppen.dk
35
36 www.argoclima.com
www.koelegruppen.dk
PACKAGE DC INVERTER
eco
auto restart
R410A
ifeel
integrated
plenum
3speed
H
H3
+43°C
-15°C
H3B
ADS 125 PH/H3
• PAM DC Inverter teknologi
• Vaskbare filtre
• Firevejs rørtilslutning
• Automatisk skift mellem køl og varme
• Natfunktion
• Affugtning
• Auto restart efter strømsvigt
• Elektronisk sikring mod strømsvigt
• Driftsikker i både køl og varme ned til -15°C
• 230V eller 400V forsyning
• Højeffektivitets kompressor
Cooling/Heating capacity - nominal (min-max)
Energy label class
E.E.R. / C.O.P.
Air flowrate (h.m.l.)
Dehumidification
External static pressure (min-max)
Fan speeds (Indoor / Outdoor)
Sound power Indoor (h.m.l.)
Sound pressure Indoor (h.m.l.)
Sound pressure Indoor at ducts exit
Sound pressure Outdoor (h.)
Power supply (1ph-3ph)
Running consumption - nominal (min-max)
Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE
Compressor type
Refrigerant type
Liquid pipe diameter
Gas pipe diameter
Max. pipe lenght with gas standard charge
Max. pipe lenght with gas additional charge
Max. height between units (Outdoor on top)
Max. height between units (Indoor on top)
Ducts diameter
Net weight Indoor / Outdoor
Net dimension Indoor (H./W./D.)
Net dimension Outdoor (H./W./D.)
Units
kW
BTU/h
kcal/h
ABCDEFG
(kW/kW)
mK
l/h
mm W.C.
n°
dB(A)
dB(A)
dB(A)
dB(A)
V/Ph/Hz
kW
kWh
mm(inch")
mm(inch")
m
m
m
m
mm
Kg
mm
mm
ADS125PH/H3/H3B
ADS125PH
AES125PIH/H3/H3B
Cooling
Heating
12,50 (2,7-14,0)
14,00 (2,7-16,00)
42.500
48.000
10.750
12.040
C
C
2,87
3,26
1.980-1.560-1.320
6,6
5-10
3 + Auto / variable
49-46-42
40-37-33
20
52
53
230/1/50 - 400/3/50
4,36
4,29
2.180
DCInverter Twin Rotary
R410A
9,52(3/8")
15,88(5/8")
30
50
30
15
200
47/100
310x1.480x630
1.230x940x340
SPLIT/PACKAGE ON OFF
PRODUCT NAME
Indoor unit
Outdoor unit (1ph/3ph)
Features
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
www.argoclima.com
www.koelegruppen.dk
37
PACKAGE DC INVERTER
eco
auto restart
R410A
ifeel
washable
filters
3speed
+43°C
-15°C
ACS 71/100 PH/H3
• PAM DC Inverter teknologi
• Automatisk skift mellem køl og varme
• Natfunktion
• Affugtning
• Auto restart efter strømsvigt
• Elektronisk sikring mod strømsvigt
• Driftsikker i både køl og varme ned til -15°C
• 230V eller 400V forsyning
• Højeffektivitets kompressor
• Vaskbare filtre
PRODUCT NAME
Indoor unit
Outdoor unit (1ph/3ph)
Features
Cooling/Heating capacity - nominal (min-max)
Energy label class
E.E.R. / C.O.P.
Air flowrate Indoor (h.m.l.)
Dehumidification
Fan speeds (Indoor / Outdoor)
Sound pressure Indoor (h.m.l.)
Sound pressure Outdoor (h.)
Power supply (1ph-3ph)
Running consumption
Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE
Compressor type
Refrigerant type
Liquid pipe diameter
Gas pipe diameter
Max. pipe lenght with gas standard charge
Max. pipe lenght with gas additional charge
Max. height between units (Outdoor on top)
Max. height between units (Indoor on top)
Net weight Indoor / Outdoor
Net dimension Indoor (H./W./D.)
Net dimension Outdoor (H./W./D.)
Units
kW
BTU/h
kcal/h
ABCDEFG
(kW/kW)
m³/h
l/h
n°
dB(A)
dB(A)
V/Ph/Hz
kW
kWh
mm(inch")
mm(inch")
m
m
m
m
Kg
mm
mm
ACS71PH/H3/H3B
ACS71PH
AES71PIH/H3/H3B
Cooling
Heating
7,10 (2,2-8,0)
8,00 (2,2-9,0)
24.000
27.000
6.100
6.880
B
B
3,02
3,56
1.098-900-840
3,0
3 + Auto / variable
38-36-33
47
49
230/1/50 - 400/3/50
2,35
2,25
1.175
DCInverter Twin Rotary
R410A
9,52(3/8")
15,88(5/8")
30
50
30
15
25/58
210x1.180x680
780x940x340
ACS100PH/H3/H3B
ACS100PH
AES100PIH/H3/H3B
Cooling
Heating
10,00 (2,2-11,2)
11,20 (2,2-12,50)
34.000
38.000
8.600
9.630
B
A
3,04
3,67
1.650-1.380-1.200
3,9
3 + Auto / variable
41-38-35
51
52
230/1/50 - 400/3/50
3,29
3,67
1.645
DCInverter Twin Rotary
R410A
9,52(3/8")
15,88(5/8")
30
50
30
15
33/65
210x1.595x680
780x940x340
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
38 www.argoclima.com
www.koelegruppen.dk
PACKAGE DC INVERTER
eco
auto restart
R410A
washable
filters
ifeel
3speed
H
H3
+43°C
-15°C
H3B
ACS 125 PH/H3
• PAM DC Inverter teknologi
• Automatisk skift mellem køl og varme
• Natfunktion
• Affugtning
• Auto restart efter strømsvigt
• Elektronisk sikring mod strømsvigt
• Driftsikker i både køl og varme ned til -15°C
• 230V eller 400V forsyning
• Højeffektivitets kompressor
• Vaskbare filtre
Cooling/Heating capacity - nominal (min-max)
Energy label class
E.E.R. / C.O.P.
Air flowrate Indoor (h.m.l.)
Dehumidification
Fan speeds (Indoor / Outdoor)
Sound pressure Indoor (h.m.l.)
Sound pressure Outdoor (h.)
Power supply (1ph-3ph)
Running consumption
Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE
Compressor type
Refrigerant type
Liquid pipe diameter
Gas pipe diameter
Max. pipe lenght with gas standard charge
Max. pipe lenght with gas additional charge
Max. height between units (Outdoor on top)
Max. height between units (Indoor on top)
Net weight Indoor / Outdoor
Net dimension Indoor (H./W./D.)
Net dimension Outdoor (H./W./D.)
Units
kW
BTU/h
kcal/h
ABCDEFG
(kW/kW)
m³/h
l/h
n°
dB(A)
dB(A)
V/Ph/Hz
kW
kWh
mm(inch")
mm(inch")
m
m
m
m
Kg
mm
mm
ACS125PH/H3/H3B
ACS125PH
AES125PIH/H3/H3B
Cooling
Heating
12,50 (2,7-14,0)
14,00 (2,7-16,00)
42.500
48.000
10.750
12.040
B
B
3,03
3,44
1.800-1.560-1.320
5,6
3 + Auto / variable
43-40-37
52
53
230/1/50 - 400/3/50
4,12
4,07
2.060
DCInverter Twin Rotary
R410A
9,52(3/8")
15,88(5/8")
30
50
30
15
35/100
210x1.595x680
1.230x940x340
SPLIT/PACKAGE ON OFF
PRODUCT NAME
Indoor unit
Outdoor unit (1ph/3ph)
Features
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
www.argoclima.com
www.koelegruppen.dk
39

Similar documents

Linear guides for LinMot Motors

Linear guides for LinMot Motors - Options : . Adaptation kit for sensor MS01-1D : /MS after Order No. . 2 end of stroke hydraulic shock absorber (Order No. : 8319175) . Carriages with plastic spacers between rolling elements for ...

More information