Argo_Professional_Katalog_2011
Transcription
Argo_Professional_Katalog_2011
SPLIT/PACKAGE SPLIT/PACKAGE DCI ON OFF SPLIT/PACKAGE DCI DCI Split og pac inverter varmepumper op til 14 kW Til væg, loft eller indbygningsmontage www.argoclima.com www.koelegruppen.dk 31 PACKAGE DC INVERTER eco auto restart R410A ifeel washable filters 3speed +43°C -15°C AWS 71 PH/H3 • PAM DC Inverter teknologi • Automatisk skift mellem køl og varme • Natfunktion • Affugtning • 3-hastigheds ventilator • Flap som kan indstilles til fast eller varierende luftfordeling • Vertikal flap til manuel styring • Auto restart efter strømsvigt • Elektronisk sikring mod strømsvigt • Driftsikker i både køl og varme ned til -15°C • 230V eller 400V forsyning • Højeffektivitets kompressor PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity - nominal (min-max) Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m³/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm AWS71PH/H3/H3B AWS71PH AES71PIH/H3/H3B Cooling Heating 7,10 (2,2-8,0) 8,00 (2,2-9,0) 24.000 27.000 6.100 6.880 B B 3,01 3,54 1.140-1.020-840 4,0 3 + Auto / 3 (Auto) 41-37-34 49 230/1/50-400/3/50 2,36 2,26 1.180 DCInverter Twin Rotary R410A 9,52(3/8") 15,88(5/8") 30 50 40 50 30 21/58 330x1.140x228 780x940x340 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC 32 www.argoclima.com www.koelegruppen.dk PACKAGE DC INVERTER eco auto restart R410A ifeel washable filters 3speed +43°C -15°C ASS 71/100 PH/H3 • PAM DC Inverter teknologi • Automatisk skift mellem køl og varme • Natfunktion • Affugtning • 3-hastigheds ventilator • Flap som kan indstilles til fast eller varierende luftfordeling • Auto restart efter strømsvigt • Elektronisk sikring mod strømsvigt • Driftsikker i både køl og varme ned til -15°C • 230V eller 400V forsyning • Højeffektivitets kompressor PRODUCT NAME Indoor unit Outdoor unit (1ph/3ph) Features Cooling/Heating capacity - nominal (min-max) Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply (1ph-3ph) Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m³/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m m m Kg mm mm ASS71PH/H3/H3B ASS71PH AES71PIH/H3/H3B Cooling Heating 7,10 (2,2-8,0) 8,00 (2,2-9,0) 24.000 27.000 6.100 6.880 A A 3,33 3,86 1.140-1.020-840 3,6 3 + Auto / variable 47-45-41 47 49 230/1/50 - 400/3/50 2,13 2,07 1.065 DCInverter Twin Rotary R410A 9,52(3/8") 15,88(5/8") 30 50 30 15 28/58 338x860x860 780x940x340 SPLIT/PACKAGE ON OFF • Vaskbare filtre ASS100PH/H3/H3B ASS100PH AES100PIH/H3/H3B Cooling Heating 10,00 (2,2-11,2) 11,20 (2,2-12,50) 34.000 38.000 8.600 9.630 A A 3,21 3,78 1.920-1.680-1.320 4,6 3 + Auto / variable 53-50-46 51 52 230/1/50 - 400/3/50 3,12 2,96 1.560 DCInverter Twin Rotary R410A 9,52(3/8") 15,88(5/8") 30 50 30 15 35/65 338x1.150x860 780x940x340 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC www.argoclima.com www.koelegruppen.dk 33 PACKAGE DC INVERTER eco auto restart R410A H ifeel washable filters 3speed H3 +43°C -15°C H3B ASS 125 PH/H3 • PAM DC Inverter teknologi • Automatisk skift mellem køl og varme • Natfunktion • Affugtning • 3-hastigheds ventilator • Flap som kan indstilles til fast eller varierende luftfordeling • Auto restart efter strømsvigt • Elektronisk sikring mod strømsvigt • Driftsikker i både køl og varme ned til -15°C • 230V eller 400V forsyning • Højeffektivitets kompressor • Vaskbare filtre PRODUCT NAME Indoor unit Outdoor unit (1ph/3ph) Features Cooling/Heating capacity - nominal (min-max) Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply (1ph-3ph) Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m³/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m m m Kg mm mm ASS125PH/H3/H3B ASS125PH AES125PIH/H3/H3B Cooling Heating 12,50 (2,7-14,0) 14,00 (2,7-16,00) 42.500 48.000 10.750 12.040 A A 3,24 3,66 1.920-1.680-1.320 6,3 3 + Auto / variable 53-50-46 52 53 230/1/50 - 400/3/50 3,86 3,83 1.930 DCInverter Twin Rotary R410A 9,52(3/8") 15,88(5/8") 30 50 30 15 35/100 338x1.150x860 1.230x940x340 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC 34 www.argoclima.com www.koelegruppen.dk PACKAGE DC INVERTER eco auto restart R410A ifeel integrated plenum 3speed +43°C -15°C ADS 71 PH/H3 • PAM DC Inverter teknologi • Trevejs rørtilslutning • Automatisk skift mellem køl og varme • Natfunktion • Affugtning • Auto restart efter strømsvigt • Elektronisk sikring mod strømsvigt • Driftsikker i både køl og varme ned til -15°C • 230V eller 400V forsyning • Højeffektivitets kompressor • Vaskbare filtre Cooling/Heating capacity - nominal (min-max) Energy label class E.E.R. / C.O.P. Air flowrate (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds (Indoor / Outdoor) Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) Sound pressure Indoor at ducts exit Sound pressure Outdoor (h.) Power supply (1ph-3ph) Running consumption - nominal (min-max) Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Ducts diameter Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) mK l/h mm W.C. n° dB(A) dB(A) dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m m m mm Kg mm mm ADS71PH/H3/H3B ADS71PH AES71PIH/H3/H3B Cooling Heating 7,10 (2,2-8,0) 8,00 (2,2-9,0) 24.000 27.000 6.100 6.880 C C 2,83 3,35 1.080-900-780 3,5 5-10 3 + Auto / variable 43-39-36 34-30-27 20 47 49 230/1/50 - 400/3/50 2,51 2,39 1.255 DCInverter Twin Rotary R410A 9,52(3/8") 15,88(5/8") 30 50 30 15 200 32/58 310x1.000x630 780x940x340 SPLIT/PACKAGE ON OFF PRODUCT NAME Indoor unit Outdoor unit (1ph/3ph) Features The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC www.argoclima.com www.koelegruppen.dk 35 36 www.argoclima.com www.koelegruppen.dk PACKAGE DC INVERTER eco auto restart R410A ifeel integrated plenum 3speed H H3 +43°C -15°C H3B ADS 125 PH/H3 • PAM DC Inverter teknologi • Vaskbare filtre • Firevejs rørtilslutning • Automatisk skift mellem køl og varme • Natfunktion • Affugtning • Auto restart efter strømsvigt • Elektronisk sikring mod strømsvigt • Driftsikker i både køl og varme ned til -15°C • 230V eller 400V forsyning • Højeffektivitets kompressor Cooling/Heating capacity - nominal (min-max) Energy label class E.E.R. / C.O.P. Air flowrate (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds (Indoor / Outdoor) Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) Sound pressure Indoor at ducts exit Sound pressure Outdoor (h.) Power supply (1ph-3ph) Running consumption - nominal (min-max) Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Ducts diameter Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) mK l/h mm W.C. n° dB(A) dB(A) dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m m m mm Kg mm mm ADS125PH/H3/H3B ADS125PH AES125PIH/H3/H3B Cooling Heating 12,50 (2,7-14,0) 14,00 (2,7-16,00) 42.500 48.000 10.750 12.040 C C 2,87 3,26 1.980-1.560-1.320 6,6 5-10 3 + Auto / variable 49-46-42 40-37-33 20 52 53 230/1/50 - 400/3/50 4,36 4,29 2.180 DCInverter Twin Rotary R410A 9,52(3/8") 15,88(5/8") 30 50 30 15 200 47/100 310x1.480x630 1.230x940x340 SPLIT/PACKAGE ON OFF PRODUCT NAME Indoor unit Outdoor unit (1ph/3ph) Features The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC www.argoclima.com www.koelegruppen.dk 37 PACKAGE DC INVERTER eco auto restart R410A ifeel washable filters 3speed +43°C -15°C ACS 71/100 PH/H3 • PAM DC Inverter teknologi • Automatisk skift mellem køl og varme • Natfunktion • Affugtning • Auto restart efter strømsvigt • Elektronisk sikring mod strømsvigt • Driftsikker i både køl og varme ned til -15°C • 230V eller 400V forsyning • Højeffektivitets kompressor • Vaskbare filtre PRODUCT NAME Indoor unit Outdoor unit (1ph/3ph) Features Cooling/Heating capacity - nominal (min-max) Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply (1ph-3ph) Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m³/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m m m Kg mm mm ACS71PH/H3/H3B ACS71PH AES71PIH/H3/H3B Cooling Heating 7,10 (2,2-8,0) 8,00 (2,2-9,0) 24.000 27.000 6.100 6.880 B B 3,02 3,56 1.098-900-840 3,0 3 + Auto / variable 38-36-33 47 49 230/1/50 - 400/3/50 2,35 2,25 1.175 DCInverter Twin Rotary R410A 9,52(3/8") 15,88(5/8") 30 50 30 15 25/58 210x1.180x680 780x940x340 ACS100PH/H3/H3B ACS100PH AES100PIH/H3/H3B Cooling Heating 10,00 (2,2-11,2) 11,20 (2,2-12,50) 34.000 38.000 8.600 9.630 B A 3,04 3,67 1.650-1.380-1.200 3,9 3 + Auto / variable 41-38-35 51 52 230/1/50 - 400/3/50 3,29 3,67 1.645 DCInverter Twin Rotary R410A 9,52(3/8") 15,88(5/8") 30 50 30 15 33/65 210x1.595x680 780x940x340 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC 38 www.argoclima.com www.koelegruppen.dk PACKAGE DC INVERTER eco auto restart R410A washable filters ifeel 3speed H H3 +43°C -15°C H3B ACS 125 PH/H3 • PAM DC Inverter teknologi • Automatisk skift mellem køl og varme • Natfunktion • Affugtning • Auto restart efter strømsvigt • Elektronisk sikring mod strømsvigt • Driftsikker i både køl og varme ned til -15°C • 230V eller 400V forsyning • Højeffektivitets kompressor • Vaskbare filtre Cooling/Heating capacity - nominal (min-max) Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply (1ph-3ph) Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m³/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m m m Kg mm mm ACS125PH/H3/H3B ACS125PH AES125PIH/H3/H3B Cooling Heating 12,50 (2,7-14,0) 14,00 (2,7-16,00) 42.500 48.000 10.750 12.040 B B 3,03 3,44 1.800-1.560-1.320 5,6 3 + Auto / variable 43-40-37 52 53 230/1/50 - 400/3/50 4,12 4,07 2.060 DCInverter Twin Rotary R410A 9,52(3/8") 15,88(5/8") 30 50 30 15 35/100 210x1.595x680 1.230x940x340 SPLIT/PACKAGE ON OFF PRODUCT NAME Indoor unit Outdoor unit (1ph/3ph) Features The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC www.argoclima.com www.koelegruppen.dk 39
Similar documents
Linear guides for LinMot Motors
- Options : . Adaptation kit for sensor MS01-1D : /MS after Order No. . 2 end of stroke hydraulic shock absorber (Order No. : 8319175) . Carriages with plastic spacers between rolling elements for ...
More information