HL Fan-Coil Units Low-Profile, Horizontal - Enviro-Tec
Transcription
HL Fan-Coil Units Low-Profile, Horizontal - Enviro-Tec
HL Fan-Coil Units Low-Profile, Horizontal HL Fan-Coil Units: Innovative design simplifies installation and service Owners AHRI Standard 440-certification ensures exacting performance. The HL fan-coil unit’s 3-speed, directdrive motor allows optimized cabinet airflow and sound performance. Enhanced sound levels are achieved through an electronic fan-speed controller (SCR) which allows further motor-speed tuning. HL concealed model fan-coil units are constructed of galvanized steel, surpassing the ASTM 125-hour, salt-spray test for corrosion and rust. Exposed-cabinet model HLE features durable, powder-coated, galvanealed steel that resists fading, scratches and fingerprints. Concerned about Indoor Air Quality? Sloped drain pans are standard on all HL units, and are easily removed to provide access to the coils for cleaning. Optional stainless-steel drain pans and coil casings are available. IAQ lining options include foil-faced or elastomeric, closed-cell-foam insulation. HL Fan-Coil Unit Airflow (CFM) Model and Unit Size Nominal HLP/HLF 20 HLE 20 250 250 HLP/HLF 25 HLE 25 400 350 HLP/HLF 30 HLE 30 500 450 HLP/HLF 40 HLE 40 750 650 HLP/HLF 50 HLE 50 1000 850 HLP/HLF 60 HLE 60 1400 1200 Actual performance may vary based on model, options and operating conditions. Refer to Web-Select ® at enviro-tec.com for complete performance information. Designers The HL unit’s impressive list of standard features provides unparalleled design flexibility. Configuration options include rear-ducted or bottom-ducted return. Ceiling access is achieved through architectural-louvered or solid return-air panels, or a telescoping-duct panel for adjustable unit recessing. Available with chilled-water or DX cooling coils, and hot-water, steam or electric heating coils, HL fan coils produce the ultimate in comfort and flexibility. Contractors HL horizontal fan-coil units provide maximum performance while reducing installed cost to the contractor. Ultra-low-profile design (maximum 10" for concealed models; 12" for exposed cabinets) allows installation virtually anywhere. Bottom access to all components through available hinged-cover access doors makes service easy. For fast-track jobs, the HL Quick Ship unit is available in 5, 10 or 15 days with an impressive list of unit options and controls. Factory-Mounted Control Packages A wide variety of control options and thermostats are offered. Factory-mounting and wiring of DDC controls by others is also available. Silent Relays Silent, solid-state relays are available for fan and electric-heat control in sound-sensitive environments. Factory-Furnished Valve Packages Valve packages provided by the factory ensure proper fit, operation and performance. Electric Heat A variety of kW and voltage configurations are available. Options include door-interlock disconnects, low-voltage controls, and silent, solid-state relays. All control and electric-heat configurations include singlepoint-power connection and are cETL listed as an assembly. Electrical Enclosure The bottom-hinged electrical enclosure provides access to a spacious electrical compartment. This compartment houses all electric-heat and control components. Terminal strips are furnished for simple power-wiring and controlwiring connections. Multiple knockouts allow wiring entries from either side of the compartment. Drain Pan Standard drain pans are externally insulated, single-wall, galvanized steel with an option for stainless steel. Drain pans are available with secondary drain connection. On concealed models, the HL Series drain pan is easily removable for cleaning or reversing connections. Coils All units are available in 2-pipe or 4-pipe configurations. The heating coil may be placed in the reheat or preheat position. On concealed models, heating and cooling coils are available with right, left or opposite-side connections. Separate coil casings for heating and cooling coils allow for cleaning on the entering and leaving air sides when the drain pan is removed. Filters One-inch throwaway filters are tight-fitting to prevent air bypass. Filters are easily removable from the bottom through the access panel. Powder-Coated Painted Surface Exposed-cabinet model HLE, as well as ceiling-access panels and supply and return-air grilles, feature a powder-coat finish that resists scuffing, scratching, fading, and fingerprints. Access Panels Full access to the unit for installation and service is available with both of the bottom panels removed. All electrical and piping services are accessed from the bottom. Online Rating and Selection Program The Web-Select® tool is the industry’s first web-based HVAC rating and selection program. Requiring no installation software or license fees, the Web-Select tool is accessible around the clock to representatives, owners, engineers and contractors. The beauty of this system lies in the sharing of information between users by saving selections into project schedules. Selections can be made and later edited, priced and ordered by your representative. Contact your representative for access to the Web-Select tool. 4/24/2015 Page Trims Short (5/8") Here! Telescoping Bottom Panel The telescoping bottom panel allows for fully recessing the unit while permitting service access into the ceiling plenum. The architectural ceiling panel is finished with a durable powder-coat paint. EnviroTec Selection Summary Project Name: Test 040715 Line #: 25 Selection Method: Fixed ESP/Nominal Airflow Selection Date: 4/24/2015 9:02:52 AM Coil Version: 7.01d Ship Cycle: Standard Shipment Tag: Elevation: 0 ft. Printed Date: 4/24/2015 9:03:06 AM ET Notes: This field is for user purposes only and will not transfer to the order form. General Fan Fan Fan Motor Weight* Unit Unit Airflow OA ESP Motor Motor V/P/Hz Filter Type Full Load MCA MSCP Watts Qty Speed (lb) Size Capacity (cfm) (cfm) (in.wc) (Hp) RPM Amps (1) 1" EnviroTec HLP 30 Standard 599 0 0.05 1080 1.6 2 15 165 2 115/1/60 High 94 1/10 Throwaway * Weight does not include accessories. Mfg Model Fan selection and performance is shown at elevation of 0 ft. Chilled Water Coil EAT DB/WB LAT DB/WB Total Capacity (deg.F) (deg.F) (Btuh) 75 / 60 58.1 / 53.4 11130 Sensible Capacity (Btuh) EWT/LWT (deg.F) Fluid Flow (gpm) 11000 45 / 55 2.20 Fluid PD Fluid Velocity (ft.) (fps) 8.29 Air PD (in.wc) Coil Rows 0.17 3 3.3 Coil FPI No. Circuits 10 2 Hot Water Coil EAT DB (deg.F) LAT DB (deg.F) 55 97 Sensible Capacity (Btuh) 27270 EWT/LWT (deg.F) Fluid Flow (gpm) 180 / 160 2.80 Fluid PD Fluid Velocity (ft.) (fps) 3.37 4.2 Air PD (in.wc) Coil Rows Coil FPI No. Circuits 0.07 1 10 2 Sound Power By Octave Band (dB Re 1012 Watts) Fan Deck The fan assembly is easily removed without disconnecting the ductwork for service access to motors and blowers at, or away from, the unit. Band 2 3 4 5 6 7 8 Frequency 125 250 500 1000 2000 4000 8000 Total 62 64 60 56 52 47 42 Unit data is certified in accordance with AHRI440. Sound data tested in accordance with AHRI3502000. Total sound power level data based on Horizontal Concealed Plenum Return Model with fan CFM at corresponding motor tap with 115/1/60 volt PSC motor, 4 row coil, 1" throwaway filter, 0.0" external static pressure and standard rated internal pressure losses. Unit pressure drop and CFM based upon dry coil as required by AHRI440. Scheduled motor information is for Hi Speed. The coil selection has been made at Standard conditions. Outside Airflow is a user input value for scheduling purposes. A completed selection from the Web-Select program Selections may be shared with other Web-Select users, printed, exported to a spreadsheet or AutoCAD, or saved as a PDF file for emailing. http://wwwstaging.envirotec.com/Selection/fcu.asp?action=printallselections&projectID=622619&items=622838&sound=select 1/1 Model HLP Plenum Return Dimensional Data 1/2 [13] D HANGER HOLES 6 [152] MAX Model HLE Exposed Cabinet Dimensional Data 1-1/2 [38] 1/2 [13] C 1 [25] E 30 [762] 1-1/2 [38] BOTTOM VIEW SHOWN WITH OPTIONAL BOTTOM ELECTRICAL ENCLOSURE & HINGED COVER, SEE NOTE3 30 [762] 2-1/4 [57] ELECTRICAL K.O. SEE NOTE3 14-1/4 [362] D 3/8 [10] DIA. HNGR. ROD HOLE, TYP. 3-11/16 [94] 1/2 [13] A D TWO 7/8 K.O. FOR ELECTRICAL ENTRY 3 [76] 3-11/16 [94] 1-1/8 K.O. FOR A DRAIN TUBE EXI T 5 [127] C TWO 7/8 K.O. FOR 1-1/2 ELECTRICAL ENTRY [38] 3 [76] F TOP VIEW TOP VIEW 1-5/8 [41] (Drain Pan Omitted) (Drain Pan Omitted) 5-3/8 [137] 3-1/2 [89] BOTTOM VIEW 1-5/8 [41] PARTIAL REAR VIEW STANDARD HANGER BRACKETS, NOT SHOWN IN FRONT & BOTTOM VIEW S STANDARD CONTROL ENCLOSURE, SEE NOTE 3 3/8 [10] DIA HANGER 5-3/8 ROD HOLES WITH [137] RESILIENT GROMMET [29] 3/4 [19] [13] 6-3/4 SLOPED DRAI N PAN, STANDARD 1-1/4 [32] Page Trims Short (5/8") Here! FRONT VIEW E F 3-1/2 [89] 1-1/4 [32] K.O. FOR [165] DRAIN TUBE EXI T OPTIONAL BOTTOM INLET 9 [229] REQUIRED FOR HINGED BOTTOM ENCLOSURE COVER FRONT VIEW1-5/8 [41] 33 [838] [254]7/8 K.O. TWO A FOR ELECTRICAL ENTRY B 3/4 6-1/2 1-1/8 [19] 12 [305] DRAIN PAN OUTLET, SEE NOTE4 TOP VIEW D 10 6-7/8 [175] 3 C [76] OPTIONAL AUX. DRAI N OUTLET, SEE NOTE 5 33 [838] STAMPED STEEL SUPPLY GRILLE 3-11/16 [94] B[171] 8-1/2 [216] REQUIRED FOR FILTER REMOVAL 8-1/4 1-1/2 [210] [38] STAMPED STEEL PARTIAL REAR VIEW F 3/8 [10] DIA HANGER ROD HOLES WITH RESILIENT GROMMET 2-1/4 [57] E RETURN GRILLE (TYPICAL EACH SIDE) 1-1/2 TOP [38] STAMPED STEEL FRONT VIEW SIDE VIEW FRONT VIEW RETURN GRILLE STAMPED STEEL SUPPLY GRILLE BOTTOM VIEW 6-1/2 [165] 12 [305] 5-3/8 [137] SIDE VIEW 30 [762] VIEW FRONT VIEW 8-1/4 [210] B 1-1/4 [32] 6-1/2 [165] 12 [305] D E F 3-11/16 [94] SIDE SIDEVIEW VIEW 5-3/8 [137] 3-1/2 [89] 2-1/4 [57] 1-1/8 K.O. FOR DRAIN TUBE EXI T FRONT VIEW 1-5/8 [41] 8-1/4 [210] TWO 7/8 K.O. FOR ELECTRICAL ENTRY 3 STAMPED STEEL [76] RETURN GRILLE 1-1/2 [38] 3/8 [10] DIA HANGER ROD HOLES WITH RESILIENT GROMMET PARTIAL REAR VIEW SIDE VIEW PARTIAL REAR VIEW (TYPICAL EACH SIDE) TOP VIEW STAMPED STEEL SUPPLY GRILLE Dimension Unit Size A C D E F C Unit Size Dimension A AB C D 1-1/4 [32] 33 [838] E F 27-1/2" [699] 6-1/4" [159] 20 20" [508] 21" [533] 22" [559] 19" [483] 30" [762] 20 40" [1016] 19-1/2" [495] 6-1/4" [159] 25 26" [660] 27" [686] 28" [711] 25" [635] 36" [914] 25 46" [1168] 23-1/2" [597] 6-1/4"[305] [159] 35-1/2"[165] [902] 5-1/4" [133] 30 30" [762] 31" [787] 32" [813] 29" [737] 40" [1016] 30 50" [1270] 27-1/2" [699] 7-1/4" [184] 39-1/2" [1003] 5-1/4" [133] 40 40" [1016] 41" [1041] 42" [1067] 39" [991] 50" [1270] 40 60" [1524] E 39-1/2" [1003] 6-1/4" [159] 47-1/2" [1207] 6-1/4" [159] [210] STAMPED STEEL [1207] 7-1/4" [184] RETURN GRILLE 59-1/2" [1511] 5-1/4" [133] 67-1/2" [1715] SIDE 6-1/4" [159] VIEW F 50 50" [1270] 51" [1295] 52" [1321] 49" [1245] 60" [1524] 50 60 60" [1524] 61" [1549] 62" [1575] 59" [1499] 70" [1778] 60 GENERAL NOTES: 1. A ll dimensions in inches [mm] and are ± 1/4" [6mm]. Metric values are soft conversion. 2. L eft-hand unit shown; right-hand unit opposite. HLP NOTES: 1. S tandard control enclosure is mounted on unit side opposite cooling-coil connections. Unit casing includes (2) knockouts on each side. Provide sufficient clearance to access electrical controls and comply with applicable codes and ordinances. 2. O ptional bottom control enclosure with hinged cover replaces standard side-mounted enclosure and includes (2) additional knockouts on bottom of unit, on left side. 70" [1778] 47-1/2" FRONT 80" [2032] VIEW 59-1/2" [1511] 3. S tandard, externally foam-coated, galvanized-steel drain pan has 7/8" ODM copper outlet. Stainlesssteel drain pan has 3/4" MPT galvanized-steel outlet. 4. A uxilliary drain outlet is 5/8" ODM copper or 3/8" MPT galvanized steel respectively. 5. S ee coil connection drawings for coil connection sizes and locations. HLE NOTES: 1. E lectrical enclosure size and location may vary with optional features. Provide sufficient clearance to access electrical controls and comply with applicable codes and ordinances. 2. D rain piping should be routed through casing opening indicated to provide proper drain slope. 2-1/4 [57] SIDE VIEW 33 [838] A C 3/8 [10] DIA HANGER ROD HOLES WITH RESILIENT GROMMET (TYPICAL EACH SIDE) A C 1-1/2 [38] TOP VIEW VIEW 1-1/8 PARTIAL REARTOP VIEW 26-3/8 [670] STAMPED STEEL 1/2 SUPPLY GRILLE 1-1/2 [38] 3-1/2 [89] (TYPICAL EACH SIDE) 1-1/2 [38] 30 [762] 1-1/8 K.O. FOR DRAIN TUBE EXI T 12 6-1/4" [159] 6-1/2 8-1/4 3. L ouvered bottom panel is hinged and removable for access to filter and fan assembly. 4. F ixed bottom panel is removable for access to optional electrical enclosure, coil, and drain pan. 5. Internal insulation of field-piping may be required. 6. F ield-piping casing penetrations must be cut in the field to match individual job requirements. NOTE: All data and dimensions are subject to change without notice. Refer to www.enviro-tec.com for current submittal drawings and other unit arrangements. 2-1/4 [57] HL Fan-Coil Unit Features STANDARD FEATURES: OPTIONAL FEATURES: Construction All Units Construction All Units • AHRI Standard 440-certified and labeled • Galvanized-steel construction • 1/2" thick fiberglass insulation • 1 1/2" duct discharge collar • Four-point hanger mounting brackets Plenum Units • Integral filter rack with 1" throwaway filter • Integral rear-ducted return—field-reversible to bottom return Exposed Units • Stamped louver supply-air and return-air grille • Durable powder-coat paint • 18 gauge bottom-panel construction Coils • Cooling: 3 or 4-row chilled water or DX, heat-pump compatible • Heating: 1 or 2-row hot water or steam — reheat or preheat position • 6 total rows of cooling and heating coils maximum • 1/2" O.D. seamless copper tubes • 0.016" tube-wall thickness • High-efficiency, aluminum-fin surface for optimizing heat transfer, pressure drop and carryover • Left-hand or right-hand, same or opposite-side connections • Access to entering and leaving air sides for cleaning • Removable for service • Manual air vents Drain Pans • Single-wall, galvanized-steel, externally insulated — fire-retardant and antimicrobial • Positively sloped to drain connection • Removable, field-reversible • 7/8" O.D. primary-drain connection Fan Assemblies • Forward-curved, DWDI, centrifugal-type blowers • 115-volt, single-phase, three-tap PSC motors • Quick-disconnect motor connections • Removable fan/motor deck for service Electrical • cETL listed for safety compliance • Electrical junction box for field-wiring terminations • Terminal block for field connections Electric Heat • ETL-listed as an assembly for safety compliance • Integral electric-heat assembly with removable elements for easy service • Automatic-reset primary and back-up secondary thermal limits • Single-point-power connection • Bottom-hinged electrical enclosure • Foil-faced fiberglass insulation • Elastomeric, closed-cell-foam insulation Plenum Units • Bottom return • 1" pleated filters (MERV 6) • Spare 1" throwaway filters • Telescoping-bottom panels Exposed Units • 1" pleated filters (MERV 6) • Double-deflection discharge grille • Ducted supply and/or return Coils • Automatic air vents • Stainless-steel coil casings • 0.025" tube wall (standard on steam) Drain Pans • Stainless-steel construction with external insulation • 5/8" O.D. secondary-drain connection • Auxiliary drip pans, galvanized or stainless-steel Fan Assemblies • 208-230, 220 & 277-volt, single-phase, three-tap PSC motors Electrical • Bottom-hinged-cover electrical enclosure • SCR fan-speed controller • Fan-relay packages • Silent, solid-state fan relays • Toggle-disconnect switch • Condensate-overflow switch (drain pan) • Main fusing • Unit and remote-mounted, three-speed fan switches Electric Heat • Manual-reset, secondary thermal limits • Door-interlocking disconnect switches • Main fusing • Field-installable with ETL-listed kit • Silent relay/contactors Piping Packages • Factory-assembled — shipped loose for field installation • 1/2" and 3/4", 2-way and 3-way, normally closed, two-position, electric, motorized valves • Isolation ball valves with memory stop • Fixed-flow and adjustable-flow control devices • Unions and P/T ports • Floating-point, modulating control valves • High-pressure, close-off actuators (1/2" = 50 PSIG; 3/4" = 25 PSIG) Thermostats • Remote-mounted analog, digital-display, or programmable • 2-pipe and 4-pipe control sequences • Automatic and manual changeover • Integral, three-speed, fan switches ENVIRO-TEC is a registered trademark of Johnson Controls, Inc. in the United States of America and other countries. Other trademarks used herein may be trademarks or registered trademarks of other companies. PUBL-5503 (615) Supersedes PUBL-5503 (908) © 2015 Johnson Controls, Inc. P.O. Box 423, Milwaukee, WI 53201 Printed in USA www.enviro-tec.com