User Manual - SolarToday
Transcription
User Manual - SolarToday
Suntrio Plus Series User Manual SAJ Solar Inverter Suntrio Plus Series www.saj-electric.com - 0 - Suntrio Plus Series Preface Thank you for choosing an SAJ solar inverter. We are pleased to provide you with first-class products and exceptional service. This manual includes information for installation, operation, maintenance, trouble shooting and safety. Please follow the instructions of this manual so that we can ensure delivery of our professional guidance and wholehearted service. Customer-orientation is forever our commitment. We hope this document proves to be of great assistance in your journey for a cleaner, greener world. Please check for the latest version at www.saj-electric.com Guangzhou Sanjing Electric Co., Ltd. Zero-Carbon Innovator - 1 - Suntrio Plus Series Content Preface .................................................................................................... - 1 - Chapter 1 Safety Precautions .............................................................. - 4 - 1.1 Scope of Application ............................................................................... - 4 - 1.2 Safety Instructions ................................................................................... - 4 - 1.3 Target Group............................................................................................ - 5 - Chapter 2 Preparation .......................................................................... - 6 - 2.1 Safety Instructions ................................................................................... - 6 - 2.2 Explanations of Symbols......................................................................... - 8 - Chapter 3 Product Information .......................................................... - 10 - 3.1 Application Scope of Products .............................................................. - 10 - 3.2 Specification for Product Model ........................................................... - 11 - 3.3 Overview and Dimensions of products ................................................. - 11 - 3.4 Datasheet ............................................................................................... - 12 - Chapter 4 Instructions for installation ............................................... - 14 - 4.1 Safety Instructions ................................................................................. - 14 - 4.2 Pre-installation Check ........................................................................... - 14 - 4.3 The Determination of the Installation Method and Position ................. - 16 - 4.4 Mounting Procedure .............................................................................. - 18 - Chapter 5 Electrical Connection........................................................ - 20 - 5.1 Safety Instruction for Hot-line Job ........................................................ - 20 - 5.2 Specifications for Electrical Interface ................................................... - 21 - 5.3 AC Side Connection .............................................................................. - 21 - 5.4 DC Side Connection .............................................................................. - 23 - 5.5 Communication Connection.................................................................. - 26 - Chapter 6 Debugging Instructions ..................................................... - 27 - - 2 - Suntrio Plus Series 6.1 Introduction of Human-computer Interface .......................................... - 27 - 6.2 First Run Setup ...................................................................................... - 28 - 6.3 Monitoring Operation............................................................................ - 36 - Chapter 7 Fault Code and Troubleshooting ....................................... - 37 - Chapter 8 Recycling and Disposal .................................................... - 40 - Chapter 9 Guarantee Service ............................................................. - 41 - Chapter 10 Contact SAJ .................................................................... - 42 - - 3 - Suntrio Plus Series Chapter 1 Safety Precautions 1.1 Scope of Application This User Manual describes instructions and detailed procedures for installing, operating, maintaining, and troubleshooting of the following SAJ grid-tie inverters: Suntrio Plus 4K; Suntrio Plus 5K; Suntrio Plus 6K; Suntrio Plus 8K; Suntrio Plus 10K Please keep this manual all time available in case of emergency. 1.2 Safety Instructions DANGER · DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING · WARNING indicates a hazardous situation which, if not avoided, can result in death or serious injury or moderate injury. CAUTION · CAUTION indicates a hazardous condition which, if not avoided, can result in minor or moderate injury. NOTICE · NOTICE indicates a situation that can result in potential damage, if not avoided. - 4 - Suntrio Plus Series 1.3 Target Group Only qualified electricians who have read and fully understood all safety regulations contained in this manual can install, maintain and repair the inverter. Operators must be aware of the high-voltage device. - 5 - Suntrio Plus Series Chapter 2 Preparation 2.1 Safety Instructions DANGER · Dangerous due to electrical shock and high voltage. · Do not touch the operating component of the inverter, it might result in burning or death. · To prevent risk of electric shock during installation and maintenance, please make sure that all AC and DC terminals are plugged out. · Do not touch the surface of the inverter while the housing is wet, it might lead to electrical shock. · Do not stay close to the inverter while there are severe weather conditions including storm, lighting, etc. · Before opening the housing, the SAJ inverter must be disconnected from the grid and PV generator; you must wait at least five minutes to let the energy storage capacitors fully discharged after disconnecting from power source. WARNING ·The installation,service, recycling and disposal of the inverters must be performed by qualified personnel only in compliance with national and local standards and regulations. ·Any unauthorized actions including modification of product functionality of any form may cause lethal hazard to the operator, third parties, the units or their property. SAJ is not responsible for the loss and these warranty claims. ·The SAJ inverter must only be operated with PV generator. Do not connect any other source of energy to the SAJ inverter. ·Be sure that the PV generator and inverter are well grounded in order to protect properties and persons. CAUTION ·The PV inverter will become hot during operation. Please do not touch the heat sink or peripheral surface during or shortly after operation. ·Risk of damage due to improper modifications. ·Risk of damage due to improper modifications. - 6 - Suntrio Plus Series NOTICE ·Public utility only ·The PV inverter is designed to feed AC power directly to the public utility power grid; do not connect AC output of the inverter to any private AC equipment. - 7 - Suntrio Plus Series 2.2 Explanations of Symbols Symbol Description Dangerous electrical voltage This device is directly connected to public grid, thus all work to the inverter shall only be carried out by qualified personnel. DANGER to life due to high electrical voltage! There might be residual currents in inverter because of large capacitors. Wait 5 MINUTES before you remove the front lid. NOTICE, danger! This is directly connected with electricity generators and public grid. Danger of hot surface The components inside the inverter will release a lot of heat during operation. Do not touch metal plate housing during operating. An error has occurred Please go to Chapter 9 “Troubleshooting” to remedy the error. This device SHALL NOT be disposed of in residential waste Please go to Chapter 8 “Recycling and Disposal” for proper treatments. Without Transformer This inverter does not use transformer for the isolation function. Security Certificate The inverter complies with European product safety instructions. CE Mark Equipment with the CE mark fulfills the basic requirements of the Guideline Governing Low-Voltage and Electro-magnetic Compatibility. SAA Mark The inverter complies with the requirement of Equipment and Product Safety Act in Australia. - 8 - Suntrio Plus Series CQC Mark The inverter complies with the safety instructions from China's Quality Center. No unauthorized perforations or modifications Any unauthorized perforations or modifications are strictly forbidden, if any defect or damage (device/person) is occurred, SAJ shall not take any responsibility for it. - 9 - Suntrio Plus Series Chapter 3 Product Information 3.1 Application Scope of Products Suntrio Plus series products are grid-tie single phase inverters without transformers, and the inverters are important components of grid-tie solar power systems. The Suntrio Plus inverters change the DC generated by solar panels into AC which is in accordance with the requirements of public grid, and send the AC into the grid, Table 3.1 shows the structural diagram of the typical application system of Suntrio Plus inverters. Name Description Remarks A Solar panels Monocrystalline or polycrystalline silicon, and thin-film PV modules with II protection and need no ground connection B Inverters C Metering equipment Standard metering tool for measuring the output electric power of inverters D Power grid TT,TN-C,TN-S,TN-C-S Suntrio Plus 4K/5K/6K/8K/10K Table 3.1 Systematic Configuration Diagram - 10 - Suntrio Plus Series 3.2 Specification for Product Model Suntrio Plus XK ① ② ① Suntrio Plus represents for product name. ② XK represents rated power XkW of inverter, for example 5K means 5kW. 3.3 Overview and Dimensions of products The dimensions of Sununo Plus series products is shown in Figure 3.2. Figure 3.2 Dimensions of Sunttrio Plus 4K/5K/6K/8K/10K - 11 - Suntrio Plus Series 3.4 Datasheet Sunttrio Plus 4K/5K/6K/8K/10K Type Input (DC) Max. DC Power [W] Max. DC Voltage [V] MPPT Voltage Range [V] Nominal DC Voltage [V] Start Voltage[V] Min. DC Voltage[V] Max. DC Input Current PV1 / PV2 [A] Number of MPPT Number of DC Connection Sets per MPPT DC Switch Output (AC) Rated AC Power [VA] (@230V,50Hz) Max. AC Apparent Power [VA] Rated AC Current[A] Max. AC Current [A] Nominal AC voltage/ range Grid frequency/ range Power factor,adjustable Total Harmonic Distortion (THDi) Feed-in Phase / Connection Phase Efficiency Max. Efficiency Euro Efficiency (at 600Vdc) MPPT Accuracy Protection Internal Over-voltage Protection DC Insulation Monitoring DCI Monitoring GFCI Monitoring Suntrio Plus 4K Suntrio Plus 5K Suntrio Plus 6K Suntrio Plus 8K Suntrio Plus 10K 4200 5300 6300 1000 160-900 600 180 150 8400 10500 11/11 22/11 2 1/1 2/1 Integrated 4000 5000 6000 8000 10000 4000 5000 6000 8000 10000 5.8 7.2 8.7 11.6 14.5 6.4 8.1 9.7 12.9 15.9 3/N/PE, 220/380V,230/400V,240/415V;180V-280V/312V-485V 50Hz,60Hz /44Hz-55Hz,54-65Hz 0.9 leading~0.9 lagging < 3% (at nominal power) 3 /3 97.8% 97.0% 97.8% 97.2% 97.8% 97.4% >99.5% Integrated Integrated Integrated Integrated - 12 - 98.0 97.5 98.0 97.6 Suntrio Plus Series Grid Monitoring AC Short Circuit Current Protection Thermal Protection Anti-island protection monitoring Interface DC Connection AC Connection LCD Display Display Language Datalogger & Communication General Data Topology Consumption at Night [W] Consumption at Standby [W] Operating Temperature Range Cooling Method Ambient Humidity Altitude Noise [dBA] Ingress Protection Mounting Dimensions (H*W*D) [mm] Net Weight [kg] Standard Warranty [Year] Certificates Integrated Integrated Integrated AFD MC4/H4 Plug-in connector 3.5 inch Graphic LCD Display, Backlight, Inverter Parameter and Data Display Multi Language 1*RS485/1*RS232/WiFi(Optional) Transformerless <0.6 <10 -25°C to +60°C(45°C to 60°C with derating) Natural Convection 0% to 100% Non-condensing Up to 2000m (without power derating) <29 IP65 (Indoor & Outdoor Installation) Rear Panel 530*355*190 530*355*200 22 24.6 5 (standard)/10/15/20/25 (Optional) IEC62109-1/2, IEC61000-6-2/3, IEC61683, IEC60068-2, IEC62116, IEC61717, PEA/MEA, NRS 097-2-1, UTE-C-15-712-1, VDE0126-1-1/A1, VDE-AR-N 4105, AS4777.2, AS4777.3, C-TICK, CQC NB/T 32004, G83-2,NBR 16149, NBR 16150, TF 3.2.1 - 13 - Suntrio Plus Series Chapter 4 Instructions for installation 4.1 Safety Instructions DANGER · Dangerous to life due to potential fire or electricity shock. · Do not install the inverter near any inflammable or explosive items. · This inverter will be directly connected with HIGH VOLTAGE power generation device; the installation must be performed by qualified personnel only in compliance with national and local standards and regulations. NOTICE · This equipment is suit for the pollution degree II. · Inappropriate or the harmonized installation environment may jeopardize the life span of the inverter. · Installation directly exposed under intensive sunlight is not recommended. · The installation site must have good ventilation condition. 4.2 Pre-installation Check 4.2.1 Check the Package Although SAJ’s inverters have surpassed stringent testing and are checked before they leave the factory, it is possible that the inverters may suffer damages during transportation. Please check the package for any obvious signs of damage and if such evidence is present, do not open the package and contact your dealer as soon as possible. - 14 - Suntrio Plus Series 4.2.2 Check the Assembly Parts After opening the package, please refer to Table 4.1 and 4.2 to check the completeness of the assembly parts. Please contact your dealer if anything is damaged or missing. A B C E D F G H I J Table 4.1 Assembly Parts List Sequence Number Name Quantity Unit A Inverter 1 Set B Rear Panel 1 piece C DC connector 2 3 Pair D RS485 Connector 1 piece E M6×50 hex head screw 3 piece F Expansion tube 3 piece G M5×12 hex head screw and gasket 2 piece H AC connector 1 piece I User Manual 1 Copy J Warranty card 1 Copy Remarks Suntrio Plus 4K/5K/6K Suntrio Plus 8K/10K Table 4.2 Quantity of Assembly Parts and Instructions - 15 - Suntrio Plus Series 4.3 The Determination of the Installation Method and Position 4.3.1 Mounting Method Please mount the inverter rightly as shown in Figure4.1 below. Figure 4.1 Mounting Method ① The equipment employs natural convection cooling, and it can be installed indoor or outdoor. ② Please install the equipment under the guidance of Figure4.1. Vertical installation on floor level is recommended. Mount vertically or tilted backwards by max. 15°. Never install the inverter tilted forward, sideways, horizontally or upside down. ③ Install the inverter at eye level for convenience when checking the LCD display and possible maintenance activities. ④ When mounting the inverter, please consider that disassembly for service work may be required. - 16 - Suntrio Plus Series 4.3.2 Installation Position Do not expose the inverter to direct solar irradiation as this could cause power derating due to overheating.The ambient temperature should be between -25°C ~ +60°C (-13° F ~ 140° F) to ensure optimum operation.Choose locations with sufficient air exchange. Ensure additional ventilation,when necessary. To make sure the installation spot is suitably ventilated, if multiple SAJ grid-tie solar inverters are installed in the same area, the following safety clearance in Figure4.2 shall be followed for 30CM appropriate ventilation conditions. 50CM 50CM 30CM 30CM Figure 4.2 Minimum Clearance - 17 - 50cm 30cm 30cm 80cm 50cm 50cm 80cm 50cm 30cm 80cm 50cm 80cm 50cm 80cm 50cm 30cm 50cm 50cm 50cm Suntrio Plus Series 4.4 Mounting Procedure 4.4.1 Mark the Positions of the Drill Holes of the Rear Panel The position of the drill holes can be determined by using rear panel. See Figure 4.3 below: Figure 4.3 Dimensions of Rear Panel 4.4.2 Drill Holes and Place the Expansion Tubes According to the guides, drill 3 holes in the wall as shown in Figure 4.4 (in conformity with position marked in the above mentioned figure), and then place expansion tubes in the holes using a rubber mallet. Figure 4.4 Drill Holes - 18 - Suntrio Plus Series 4.4.3 Mount the Screws and the Rear Panel The panels should be mounted in the mounting position by screws as shown in Figure 4.5. Figure 4.5 Mount the Rear Panel 4.4.4 Mount the Inverter Carefully mount the inverter to the rear panel. Make sure that the rear part of the equipment is closely mounted to the rear panel. Figure 4.6 Mount the Inverter - 19 - Suntrio Plus Series Chapter 5 Electrical Connection 5.1 Safety Instruction for Hot-line Job Electrical connections must only be operated on by professional technicians. Please keep in mind that the inverter is a bi-power supply equipment. Before connection, necessary protective equipment must be employed by technicians including insulating gloves, insulating shoes and safety helmet. DANGER · Dangerous to life due to potential fire or electricity shock. · When power-on, the equipment should in conformity with national rules and regulations. · The direct connection between the converter and high voltage power systems must be operated by qualified technicians in accordance with local and national power grid standards and regulations. WARNING ·When the photovoltaic array is exposed to light, it supplies a d.c voltage to the inverter. NOTICE ·Electrical connection should in conformity with proper stipulations, such as stipulations for cross-sectional area of conductors, fuse and ground protection. ·The overvoltage category on DC input port is II,on AC output port is III. - 20 - Suntrio Plus Series 5.2 Specifications for Electrical Interface A B CD E Figure 5.1 Electrical Interface Code A B C D E Name DC Input DC Switch RS232/Wi-Fi Port RS485 Port AC Quick-connect Terminal Table 5.1 Specifications for Interface 5.3 AC Side Connection Cross-sectional Area of Cables(mm²) Scope 4.0-6.0 Recommended Value 6.0 Outside Diameter of the Cables(mm) 4.2~5.3 Table 5.2 Recommended Specifications of AC Cables - 21 - Suntrio Plus Series 5.3.1 Feed the AC Cable Through the AC Waterproof hole. Figure 5.2 Feed the cables 5.3.2 Connect the cables according to connection marks of L1,L2,L3,N and PE. Figure 5.3 Connect the Cables 5.3.3 Secure all Parts of the AC Connector Tightly. Figure 5.4 Screw the Connector - 22 - Suntrio Plus Series 5.3.4 Plug in the AC connector to the equipment securely, ensuring the pins are connected directly. Then the connection of AC cable is complete. Figure 5.5 Connect the Inverter 5.4 DC Side Connection Cross-sectional Area of Cables(mm²) Scope 4.0-6.0 Recommended Value 4.0 Outside Diameter of the Cables(mm) 4.2~5.3 Table5.3 Recommended Specifications of DC Cables DC connector is made up of the positive connector and the cathode connector 1. Insulated Enclosure 2. Lock Screw Figure 5.6 Positive Connector - 23 - 3. Positive Connector Suntrio Plus Series 1. Insulated Enclosure 2. Lock Screw 3. Cathode Connector Figure 5.7 Cathode Connector NOTICE ·Please place the connector separately after unpacking in order to avoid confusion for connection of cables. ·Please connect the positive connector to the positive side of the solar panels, and connect the cathode connector to the cathode side of the solar side. Be sure to connect them in right position. Connecting Procedures: (1)Tighten the lock screws on positive and cathode connector. (2)Use specified strip tool to strip the insulated enclosure of the positive and cathode cables to the appropriate length. 1.Positive Cable 2. Cathode Cable Figure 5.8 Connecting Cables - 24 - Suntrio Plus Series (3)Feed the positive and cathode cables into corresponding lock screws. (4)Put the metal positive and cathode terminals into positive cable and cathode cable whose insulated enclosure has been stripped, and crimp them tightly with a wire crimper. Make sure that the withdrawal force of the pressed cable is bigger than 400N. (5)Plug the pressed positive and cathode cables into relevant insulated enclosure, a “click” should be heard or felt when the contact cable assembly is seated correctly. (6)Fasten the lock screws on positive and negative connectors into respondent insulated enclosure and make them tight. (7) Connect the positive and cathode connectors into positive and negative DC input terminals of the inverter, a “click” should be heard or felt when the contact cable assembly is seated correctly. 1. Connection Port Figure 5.9 Connect the Inverter NOTICE ·Before insert the connector into DC input terminal of the inverter, please make sure that the DC switch of the inverter is OFF. - 25 - Suntrio Plus Series 5.5 Communication Connection Suntrio Plus 4K/5K/6K/8K/10K is equipped with an RS232 and an RS485 interface. (1) Connect the Wi-Fi modules with the interfaces of RS232and tighten the screws. Please refer toWi-Fi manual for detailed information. (2)The USB interface for RS232 is displayed in the picture below. Connect the inverter with computer and the information of the inverter can be monitored via your internet browser. Figure 5.10 Nine Serial Port Cable When using RS485 for monitoring, multi-point monitoring can be achieved by connecting the inverter with RS485 cables. Each connection port should be attached to the connector as shown in Figure 5.11 and Table 5.4. Make sure the connection is tight and secure. Figure 5.11 Three Ports Connector Number of Connector Color of Cables 1 Blue and white 2 Blue 3 Metal-shielded wire Table 5.3 Assembly Sequence of RS485 - 26 - Suntrio Plus Series Chapter 6 Debugging Instructions 6.1 Introduction of Human-computer Interface Figure 6.1 Human-computer Interface Object A B C D◀ E▶ F Description Power indicator light: yellow light: the power system of inverter is operating normally Status indicator lamp: Red LED light = Fault; Green LED light = operation; when red and green light are all off, the inverter is in initializing state or countdown for Communication light: blue light flashing = receiving data yellow light flashes = sending data Moves the cursor or the focus point to the left Moves the cursor or the focus point to the right Starts the menu / button to confirm selection G▲ Moves the cursor up or increases the setting value H▼ Moves the cursor down or reduces the setting value The inverter provides five buttons for inquiry of operational information and parameters, these five buttons can be used repeatedly. - 27 - Suntrio Plus Series 6.2 First Run Setup 6.2.1 Set The Country When the solar inverter begins to run for the first time, please configure the time of usage, and the inverter LCD will display as below: Figure 6.2 Set the Time Users can press Up, Down, Left, Right and ENT buttons to set local time and confirm the selection.Then the inverter will display the interface for country selection as shown in Figure 6.3: Figure 6.3 Set The Country Please press the "ENT" button, LCD will show the countries for option. Users can press " " or" " to select the correct country and press "ENT" button to confirm the selection. Note: The configuration of the country of usage must be set before inverter starts to run for its first time, otherwise the inverter will not on-gird.If users can not locate the corresponding country, please abort the setting and contact the after sales for confirmation. - 28 - Suntrio Plus Series 6.2.2 State If the country has been set the LCD shows the machine type when the inverter is started up, then it automatically displays the inverter operation status: Initialization, Normal,Wait, Fault or Update. Data name Initialization Normal Wait Fault Update Explanation Initialization of the system The inverter in normal (function) operation The inverter in stand-by state A fault occurs during operation The state of updating firmware Turn on the AC switch, the LCD begins to count backwards, after this, the inverter initiates connection to the grid. 6.2.3 LCD Menu Figure 6.4 LCD Menu - 29 - Suntrio Plus Series 6.2.4 Settings of General Parameters of the Inverter LCD Display 1. Settings of figures Operation Steps Graph Set In the main LCD interface, press “ENT” button to enter into the selection of “Figure”, press▼or ▲to select. The LCD displays daily, monthly, yearly and gross generating capacity. 2. Settings of System Parameter 1. In the main LCD interface, press “ENT” button, then press ▶ to enter into “Setting”. Communicate Set 2. Press ENT to enter into” Communication Settings”. Press ▼and▲to set the communication address of Wi-Fi and RS485. The Fault address is 1. - 30 - Suntrio Plus Series 1. In the main LCD interface, press “ENT” button, then press ▶ to enter into “Setting”. Language & Time 2. Press▼and then press ENT to enter into “Language & Time”. Press▲and ▼to set the language, date and time. 1. In the main LCD interface, press “ENT” button, then press ▶ to enter into “Setting”. Grid Compliance 2. Press▼and then press ENT to enter password and enter into country setting. - 31 - Suntrio Plus Series 3. Press▲and▼to select country, Then click OK to save the changes. 1. In the main LCD interface, press “ENT” button, then press ▶ to enter into “Setting”. Clear Errors 2. Press▼and then press ENT to enter into “Clear Fault Records”, click OK or return back. 1. In the main LCD interface, press “ENT” button, then Clear Energy press ▶ to enter into “Setting”. - 32 - Suntrio Plus Series 2. Press▼and then press ENT to enter into “Clear Energy”, click OK or return back. 1. In the main LCD interface, press “ENT” button, then press ▶ to enter into “Setting”. LCD Setting 2. Press▼and then press ENT to enter into “Display Settings”, and then press ▲and▼to change the sleep time of LCD, click OK or return back. 1. In the main LCD interface, press “ENT” button, then press ▶ to enter into “Setting”. - 33 - Suntrio Plus Series 2. Press▼and then press ENT to enter password, and then enter into Factory Settings. Factory Reset 3. Click OK to save the changes. 1. In the main LCD interface, press “ENT” button, then press ▶ to enter into “Setting”. Change Password 2. Press▼and then press ENT to enter password, and then enter into Reset Password. - 34 - Suntrio Plus Series 3. Enter the new password and click OK to save the change. 6.2.5 Inquiry of Parameters of Inverter 1. Inquiry of Operating Parameters 1. In the main LCD interface, press “ENT” button, then press ▶ to enter into “Parameters”. 2. Press ENT to enter into “Run-Info”, then press ▼or▲to select the needed parameters,press ENT to enter and to check the parameters. 2. Inquiry of the Information of Inverter 1. In the main LCD interface, press “ENT” button, then press ▶ to enter into “About”. 2. Press ENT to enter into “About” to check the equipment type, series number, machine code, software version of display panel, mainframe version of the control panel and the settings of country. - 35 - Suntrio Plus Series 6.3 Monitoring Operation The equipment is equipped with an RS232 and an RS485 interface, and the RS232 interface can be connected to Wi-Fi modules or USB interface which can be used in the monitoring of the operation status. ① The equipment can be connected to local internet via a Wi-Fi module and the SAJ web server which is embedded in the machine, following this, the operational status of the inverter can be monitored. ② By connecting the internet through a Wi-Fi module and uploading the data of the inverter to server, users can monitor the operational information of the inverter by web version web portal or mobile APP (please download the mobile APP from SAJ’s official website) remotely. ③ Connecting the inverter to computer by nine-serial port cable, the operational information of the inverter can be read by the appropriate computer software. ④ Users can apply a Modbus protocol through RS485 together with an SAJ Logger to monitor the data of the inverter. For detailed operation please refer to the SAJ Logger User Manual. - 36 - Suntrio Plus Series Chapter 7 Fault Code and Troubleshooting LCD displays Fault codes as shown in the table below: Error Code Explanation 01 Relay Error Master 02 Storer Error Master 03 High Temperature Master 04 Low Ttemperature Master 05 Interior Communication Master 06 GFCI Devices Error Master 07 DCI Devices Error Master 08 Current Sensor Master 09/11/13 L1/L2/L3 Voltage High Master 10/12/14 L1/L2L3 Voltage Low Master 15/16/17 L1/L2/L3 Average Voltage of 10 mimutes High Master 18/20/22 L1/L2/L3 Frequency High Master 19/21/23 L1/L2/L3 Frequency Low Master 24/25/26 L1/L2/L3 Grid Lost Error Master 27 GFCI Error Master 28/29/30 L1/L2/L3 DCI Error Master 31 Insulation Error Master 32 Bus Voltage unbalance Master 33 Bus Voltage High Master 34 Bus Voltage Low Master 35/36/37 L1/L2/L3 Current High Master 38 Bus Voltage High Of Hardware Master 39/40 PV1/PV2 Current High of Hardware Master 41/42/43 L1/L2/L3 Current High of Hardware of Grid Master 45/46/47/48 Fan 1/2/3/4 Error Master 50 Lost interior communication Slave 51/52/53 L1/L2/L3 Data Consistency of Voltage Error Slave 54/55/56 Data Consistency of Frequency Error Slave - 37 - Suntrio Plus Series 57 Data Consistency of GFCI Slave 58/59/60 L1/L2/L3 Data Consistency of DCI Slave 61/63/65 L1/L2/L3 Grid Voltage High Slave 62/64/66 L1/L2/L3 Grid Voltage Low Slave 67/69/71 L1/L2/L3 Frequency High Slave 68/70/72 L1/L2/L3 Frequency Low Slave 73/74/75 L1/L2/L3 No Grid Error Slave 76/77 PV1 /PV2 Voltage High Slave 78/79 PV1/PV2 current High Slave Table7.1 Error Code General troubleshooting methods for inverter are as follows: Fault Information Relay Error Eeprom Error Temperature High Error GFCI Device Error DCI Device Error Cureent Sensor Error AC Voltage Error Troubleshooting If this error occurs frequently, please contact your distributor or phone SAJ. If this error occurs frequently, please contact your distributor or phone SAJ. Check whether the radiator is blocked, whether the inverter is in too high or too low temperature, if the above mentioned are in normal, please contact your distributor or phone SAJ. If this error occurs frequently, please contact your distributor or phone SAJ. If this error occurs frequently, please contact your distributor or phone SAJ. If this error occurs frequently, please contact your distributor or phone SAJ. ·Check the volt of the grid ·Check the connection between the inverter and the grid. ·Check the settings of the on-grid standards of the inverter. ·If the volt of the grid is higher than the volt regulated by local grid, please inquire the local grid workers whether they can adjust the volt at the feed point or change the value of the regulated volt. ·If the volt of the grid is in regulated range as allowed and LCD still in this error, please contact your distributor or phone SAJ. - 38 - Suntrio Plus Series Frequency Error No Grid Error GFCI Error DCI Error ISO Error Current High Bus Voltage High PV Current High PV Voltage Fault Lost Communication Check the set of country and check the frequency of the local grid, if the above mentioned are in normal, please contact your distributor or phone SAJ. Check the connection status between the AC side of the inverter and the grid, if the above mentioned are in normal, please contact your distributor or phone SAJ. Check the insulation resistance of the positive side and cathode side of the solar panel; check whether the inverter is in wet environment; check the grounding of the inverter. If the above mentioned are in normal, please contact your distributor or phone SAJ. If this error exists always, please contact your distributor or phone SAJ. Check the insulation resistance of the positive side and cathode side of the solar panel; check whether the inverter is in wet environment; check whether the grounding of the inverter is loose or not. If the above mentioned are in normal, please contact your distributor or phone SAJ. Check the connection status between the inverter and the grid and test whether the volt of the grid is stable or not, if the above mentioned are in normal, please contact your distributor or phone SAJ. Check the settings of the solar panel. SAJ’s system design software can help you.If the above mentioned are in normal, please contact your distributor or phone SAJ. If this error exists always, please contact your distributor or phone SAJ. Check the settings of the solar panel. SAJ’s system design software can help you. If the above mentioned are in normal, please contact your distributor or phone SAJ. Check the connection of communication cables between control panel and display panel. If the above mentioned are in normal, pleae contact your distributor or phone SAJ. Table 7.2 Troubleshooting - 39 - Suntrio Plus Series Chapter 8 Recycling and Disposal This device should not be disposed as residential waste. An Inverter that has reached the end of its life and is not required is to be returned to your dealer or you must find an approved collection and recycling facility in your area. - 40 - Suntrio Plus Series Chapter 9 Guarantee Service Please refer to the warranty card. - 41 - Suntrio Plus Series Chapter 10 Contact SAJ Guangzhou Sanjing Electric Co., Ltd. SAJ Innovation Park, No.9, Lizhishan Road, Guangzhou Science City, Guangdong, P.R.China. Postcode: 510663 Web: http: //www.saj-electric.com Technical Support & Service Tel: +86 20 6660 0082 Fax: +86 20 6660 8589 E-mail: service@saj-electric.com International Sales Tel: 86-20-66608618/66608619/66600082/66600086 Fax: 020-66608589 E-mail: info@saj-electric.com Domestic Sales Tel: 020-66600058/66600082 Fax: 020-66608589 - 42 - Suntrio Plus Series Guangzhou Sanjing Electric CO., LTD. ADD: SAJ Innovation Park, No.9, Lizhishan Road, Science City, Guangzhou High-tech Zone, Guangdong, P.R.China Zip: 510663 Tel: +86 20 6660 0082 Fax: 020-6660 8589 Web: http: //www.saj-electric.com Edition No: V1.0 - 43 -
Similar documents
Picture - SolarToday
Total Harmonic Distortion [THDi] Feed in phase/Connection Phase Efficiency Max. Efficiency Euro Efficiency [at 360Vdc] MPPT Accuracy Protection Internal Over-voltage Protection DC Insulation Monito...
More information